1710329816000 | 0 | None | None | Buildings | Construction of Post Metric Boys Hostel 2nd Phase at Shakthinagara, Kalaburagi District | 11796732.98 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3042958 | 102819 | None | code01 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including Additional for formwork, Centering & Scaffolding for Sl No 9 : RCC Columns As per Addendum-I in Volume-1 of page No.-111 (@70% of Finished Rate) Vol-1 (pg no 16, I No 2.5.2) Second Floor | Cum | 12459.05 | 12459.05 | 6.04 | False | None | None | False | None | False | 75252.662 | 0 | 3042959 | 102819 | None | code02 | Providing and laying in position Cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including Additional for formwork, Centering & Scaffolding for Sl No 14 : RCC beam & lintels of buildings As per Addendum-I in Volume-1 of page No.-112 (@60% of Finished Rate) Vol-1 (pg no 16, I No 2.5.2) Second Floor | Cum | 11726.16 | 11726.16 | 11.38 | False | None | None | False | None | False | 133443.7008 | 0 | 3042960 | 102819 | None | code03 | Providing and laying in position Cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including Additional for formwork, Centering & Scaffolding for Sl No 19 : Chejjas, Canopy & Other Architectural projections of minor sections As per Addendum-I in Volume-1 of page No.-112 (@45% of Finished Rate) Vol-1 (pg no 16, I No 2.5.2) Second Floor | Cum | 10626.84 | 10626.84 | 2.41 | False | None | None | False | None | False | 25610.6844 | 0 | 3042961 | 102819 | None | code04 | Providing and laying in position Cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including Additional for formwork, Centering & Scaffolding for Sl No 15 : RCC Roof slab of Buildings As per Addendumx-I in Volume-1 of page No.-112 (@50% of Finished Rate) Vol-1 (pg no 16, I No 2.5.2) Second Floor | Cum | 10993.28 | 10993.28 | 15.99 | False | None | None | False | None | False | 175782.5472 | 0 | 3042962 | 102819 | None | code05 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and
technical specification a. Buildings Vol-1 (pg no 18, I No 2.11) | Tonne | 95808.45 | 95808.45 | 4.64 | False | None | None | False | None | False | 444551.208 | 0 | 3042963 | 102819 | None | code06 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Vol-2 (pg no 14, I No 6.8) | Cum | 8534.8 | 8534.8 | 45.74 | False | None | None | False | None | False | 390381.752 | 0 | 3042964 | 102819 | None | code07 | Providing and laying in position Cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates Vol-1 (pg no 16, I No 2.4.1) | Cum | 6858.68 | 6858.68 | 5.77 | False | None | None | False | None | False | 39574.5836 | 0 | 3042965 | 102819 | None | code08 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement:4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Vol-2 (pg no 41, I No 8.1.1) | Sqm | 273.11 | 273.11 | 77.3791 | False | None | None | False | None | False | 21133.006001 | 0 | 3042966 | 102819 | None | code09 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Vol-2 (pg no 41, I No 8.2.1) | Sqm | 315.95 | 315.95 | 218.01 | False | None | None | False | None | False | 68880.2595 | 0 | 3042967 | 102819 | None | code10 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. Vol-2 (pg no 42, I No 8.8) | Sqm | 397.34 | 397.34 | 217.7 | False | None | None | False | None | False | 86500.918 | 0 | 3042968 | 102819 | None | code11 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth. Vol-2 (pg no 54, I No 8.80) | m | 70.69 | 70.69 | 300.0 | False | None | None | False | None | False | 21207.0 | 0 | 3042969 | 102819 | None | code12 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm Vol-2 (pg no 61, I No 9.17.2) | Sqm | 1258.43 | 1258.43 | 60.74 | False | None | None | False | None | False | 76437.0382 | 0 | 3042970 | 102819 | None | code13 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slabover 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Vol-2 (pg no 63, I No 9.24) | Sqm | 3054.49 | 3054.49 | 26.46 | False | None | None | False | None | False | 80821.8054 | 0 | 3042971 | 102819 | None | code14 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge Vol-2 (pg no 69, I No 10.20) | m | 351.29 | 351.29 | 64.8 | False | None | None | False | None | False | 22763.592 | 0 | 3042972 | 102819 | None | code15 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. Vol-2 (pg no 100, I No 12.13.1) | Cum | 105830.87 | 105830.87 | 0.22 | False | None | None | False | None | False | 23282.7914 | 0 | 3042973 | 102819 | None | code16 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. Vol-2 (pg no 104, I No 12.51) | Nos | 1088.14 | 1088.14 | 3.0 | False | None | None | False | None | False | 3264.42 | 0 | 3042974 | 102819 | None | code17 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial Vol-2 (pg no 105, I No 12.57.6) | Sqm | 3557.86 | 3557.86 | 7.56 | False | None | None | False | None | False | 26897.4216 | 0 | 3042975 | 102819 | None | code18 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having a overall size of 60mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm X 58mm with GI reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2-2.5 mm. Maximum possible size 1819mm x 1819mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Vol-2 (pg no 110, I No 12.88) | Sqm | 5772.69 | 5772.69 | 10.32 | False | None | None | False | None | False | 59574.1608 | 0 | 3042976 | 102819 | None | code19 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Vol-2 (pg no 109, I No 12.85) | Sqm | 6125.05 | 6125.05 | 3.96 | False | None | None | False | None | False | 24255.198 | 0 | 3042977 | 102819 | None | code20 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. Vol-2 (pg no 86, I No 11.34B) | Kg | 195.99 | 195.99 | 4268.88 | False | None | None | False | None | False | 836657.7912 | 0 | 3042978 | 102819 | None | code21 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Vol-2 (pg no 50 I No 8.51) | Sqm | 107.1 | 107.1 | 295.62 | False | None | None | False | None | False | 31660.902 | 0 | 3042979 | 102819 | None | code22 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after
thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree
angle with 10 years life). Vol-2 (pg no 46, I No 8.33.1) | Sqm | 169.22 | 169.22 | 295.62 | False | None | None | False | None | False | 50024.8164 | 0 | 3042980 | 102819 | None | code23 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Vol-2 (pg no 46, I No 8.32) | Sqm | 167.08 | 167.08 | 217.7 | False | None | None | False | None | False | 36373.316 | 0 | 3042981 | 102819 | None | code24 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Vol-2 (pg no 46, I No 8.33.2) | Sqm | 147.8 | 147.8 | 6.89 | False | None | None | False | None | False | 1018.342 | 0 | 3042982 | 102819 | None | code25 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Vol-2 (pg no 47, I No 8.33.3) | Sqm | 148.87 | 148.87 | 203.28 | False | None | None | False | None | False | 30262.2936 | 0 | 3042983 | 102819 | None | code26 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Vol-2 (pg no 85, I No 11.28) | Kg | 605.12 | 605.12 | 96.0 | False | None | None | False | None | False | 58091.52 | 0 | 3042984 | 102819 | None | code27 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification Vol-2 (pg no 149, I No 15.10) | Sqm | 875.01 | 875.01 | 359.11 | False | None | None | False | None | False | 314224.8411 | 0 | 3042985 | 102819 | None | code28 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm . Vol-2 (pg no 107, I No 12.74.1) | Nos | 109.24 | 109.24 | 9.0 | False | None | None | False | None | False | 983.16 | 0 | 3042986 | 102819 | None | code29 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete Vol-2 (pg no 108, I No 12.60) | Nos | 1126.69 | 1126.69 | 3.0 | False | None | None | False | None | False | 3380.07 | 0 | 3042987 | 102819 | None | code30 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in chargee SS Tower Bolts 250x10mm Vol-2 (pg no 218, I No 22.15.7) | Nos | 214.2 | 214.2 | 3.0 | False | None | None | False | None | False | 642.6 | 0 | 3042988 | 102819 | None | code31 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in chargee SS Aldrop 16mm dia, 300mm Vol-2 (pg no 218, I No 22.15.4) | Nos | 401.63 | 401.63 | 6.0 | False | None | None | False | None | False | 2409.78 | 0 | 3042989 | 102819 | None | code32 | Providing and fixing stainless steel 304 grade fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-incharge. 200mm length Vol-2 (pg no 218, I No 22.15.3) | Nos | 1606.5 | 1606.5 | 3.0 | False | None | None | False | None | False | 4819.5 | 0 | 3042990 | 102819 | None | code33 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in chargee SS Door Stopper 75mm Vol-2 (pg no 218, I No 22.15.10) | Nos | 107.1 | 107.1 | 3.0 | False | None | None | False | None | False | 321.3 | 0 | 3042991 | 102819 | None | code34 | Providing,fabricating and fixing Profiled Poly Urethane insulated Roof(PUF Sheet 50mm thickness) having modular density 40kg/m2 and size 1.06m width and 7.60m length sheets roof having external sheet of 0.5mm steel, bottom sheet of 0.40mm steel with powder coated finish. The precoated sheet shall be of minimum 240MPa steel conforming to IS 14246 : 1995 and shal have zinc coating with minimum 120gsm as per IS 277:1992,.The roofing system shall have suitable water proof over lapping arrangments and GRIHA ceritifed.The fasting shall be of self tapping screws of required length with PVC head along with washer pre-painted aluminium cap unit with build in seal arrangments. The entire roof shall be firmly fastened to the existng frame including all lead and lifts, loading & unloading ,usage charges of machinery and equipments, transportation charges,labour charges and all other incidental charges etc.,complete as per standard technical detailed specifications and as directed by the Engineer in charge of the work. :Vol-2 (pg no 38, I No 7.67.2) | Sqm | 2779.25 | 2779.25 | 400.44 | False | None | None | False | None | False | 1112922.87 | 0 | 3042992 | 102819 | None | code35 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Flashings/ Aprons ( Upto 600 mm) | m | 442.32 | 442.32 | 75.0 | False | None | None | False | None | False | 33174.0 | 0 | 3042993 | 102819 | None | code36 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete Gutter (600 mm over all girth):Vol-2 (pg no 27, I No 7.39.6) | m | 1150.25 | 1150.25 | 90.0 | False | None | None | False | None | False | 103522.5 | 0 | 3042994 | 102819 | None | code37 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Electric resistance or induction butt welded tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Vol-2 (pg no 83, I No 11.16.3) | Kg | 130.66 | 130.66 | 9927.87 | False | None | None | False | None | False | 1297175.4942 | 0 | 3042995 | 102819 | None | code38 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Area of slab over 0.50 m2 Vol-2 (pg no 69, I No 10.1.2) | Sqm | 4290.43 | 4290.43 | 305.28 | False | None | None | False | None | False | 1309782.4704 | 0 | 3042996 | 102819 | None | code39 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge Vol-2 (pg no 69, I No 10.2) | m | 351.29 | 351.29 | 508.8 | False | None | None | False | None | False | 178736.352 | 0 | 3042997 | 102819 | None | code40 | Providing and fixing Chorinated poly venyl cloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings,this includes jointing of pipes and fitting with one step CPVC solvent cement,trenching,refilling & testing of joints complete as per direction of Engineer incharge (external work) Item No 13.87.3 (25mm nominal OD pipes) Vol-2 (pg no 122, I No 13.33.3) | m | 310.8 | 310.8 | 250.0 | False | None | None | False | None | False | 77700.0 | 0 | 3042998 | 102819 | None | code41 | Providing and fixing Chorinated poly venyl cloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer incharge. (Concealed work including cutting chases and good the walls etc.,.) Item No 13.86.2 (20mm nominal OD pipes) Vol-2 (pg no 122, I No 13.32.2) | m | 397.95 | 397.95 | 150.0 | False | None | None | False | None | False | 59692.5 | 0 | 3042999 | 102819 | None | code42 | Providing and fixing Chorinated poly venyl cloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer incharge. (Concealed work including cutting chases and good the walls etc.,.) Item No 13.86.3 (25mm nominal OD pipes) Vol-2 (pg no 122, I No 13.32.2) | m | 500.85 | 500.85 | 50.0 | False | None | None | False | None | False | 25042.5 | 0 | 3043000 | 102819 | None | code43 | Cutting holes up to 15x15cm in R.C.C floors and roofs for passing drain pipe etc., and repairing the hole after insertion of drain pipe etc., with cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including finishing complete so as to make it leak proof Vol-2 (pg no 123, I No 13.37) | No | 328.65 | 328.65 | 10.0 | False | None | None | False | None | False | 3286.5 | 0 | 3043001 | 102819 | None | code44 | Cutting holes up to 30x30cm in walls including making good the same with common burnt clay F.P.S (non modular) bricks Vol-2 (pg no 123, I No 13.36) | Each | 339.15 | 339.15 | 20.0 | False | None | None | False | None | False | 6783.0 | 0 | 3043002 | 102819 | None | code45 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 Vol-2 (pg no 119, I No 13.16) | Nos | 651.0 | 651.0 | 6.0 | False | None | None | False | None | False | 3906.0 | 0 | 3043003 | 102819 | None | code46 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for PVC pipes 75mm dia., 6 kg/sqcm & class 3 Vol-5 (pg no 113, I No 10.1.5) | m | 231.0 | 231.0 | 30.0 | False | None | None | False | None | False | 6930.0 | 0 | 3043004 | 102819 | None | code47 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring confirming to IS : 5383, leaving 10mm gap for termal expansion (i) single socketed pepes 100mm diameter Vol-2 (pg no 125, I No 13.48) | m | 305.55 | 305.55 | 45.6 | False | None | None | False | None | False | 13933.08 | 0 | 3043005 | 102819 | None | code48 | Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0
cm X 4.0 cm with all fitting arrangements & all necessary accessories
complete Vol-2 (pg no 128, I No 13.63) | Nos | 256.2 | 256.2 | 4.0 | False | None | None | False | None | False | 1024.8 | 0 | 3043006 | 102819 | None | code49 | Concealed conduit system :supplying heavy guage PVC conduit pipe confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive pasteetc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused wires and unused junction boxes and pipe ends should be covered using PVC end enclosers. Run with 18 SWG GI fish wire wherever necessary a) 19/20mm dia 2mm thick | Mtr | 69.3 | 69.3 | 800.0 | False | None | None | False | None | False | 55440.0 | 0 | 3043007 | 102819 | None | code50 | Concealed conduit system :supplying heavy guage PVC conduit pipe confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive pasteetc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused wires and unused junction boxes and pipe ends should be covered using PVC end enclosers. Run with 18 SWG GI fish wire wherever necessary b) 25mm dia 2mm thick | Mtr | 81.9 | 81.9 | 700.0 | False | None | None | False | None | False | 57330.0 | 0 | 3043008 | 102819 | None | code51 | Groove cutting : supplying heavy guage PVC conduit pipe with bends, metal junction boxes adhesive paste etc., and bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. a) 19/20mm dia 2mm thick | Mtr | 71.4 | 71.4 | 200.0 | False | None | None | False | None | False | 14280.0 | 0 | 3043009 | 102819 | None | code52 | Groove cutting : supplying heavy guage PVC conduit pipe with bends, metal junction boxes adhesive paste etc., and bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. b) 25mm dia 2mm thick | Mtr | 82.95 | 82.95 | 100.0 | False | None | None | False | None | False | 8295.0 | 0 | 3043010 | 102819 | None | code53 | Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.
Short point upto 3Mtr from tapping point to outlet via switch box | Point | 282.45 | 282.45 | 20.0 | False | None | None | False | None | False | 5649.0 | 0 | 3043011 | 102819 | None | code54 | Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.
medium point above 3Mtr upto 6Mtr from tapping point outlet via switch box | Point | 397.95 | 397.95 | 50.0 | False | None | None | False | None | False | 19897.5 | 0 | 3043012 | 102819 | None | code55 | Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.
long point above 6Mtr upto 10Mtr tapping point to outlet via switch box | Point | 582.75 | 582.75 | 70.0 | False | None | None | False | None | False | 40792.5 | 0 | 3043013 | 102819 | None | code56 | Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.
. Two outlet in a row, above 3 Mtr upto 6Mtr from tapping point to outlet let via switches | Point | 710.85 | 710.85 | 2.0 | False | None | None | False | None | False | 1421.7 | 0 | 3043014 | 102819 | None | code57 | Supplying and flush mounting powder/galvanized coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/stone /c.c wall 1-2 way | Each | 144.9 | 144.9 | 2.0 | False | None | None | False | None | False | 289.8 | 0 | 3043015 | 102819 | None | code58 | Supplying and flush mounting powder/galvanized coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/stone /c.c wall 4-5 way | Each | 185.85 | 185.85 | 2.0 | False | None | None | False | None | False | 371.7 | 0 | 3043016 | 102819 | None | code59 | Supplying and flush mounting powder/galvanized coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/stone /c.c wall 6 way | Each | 231.0 | 231.0 | 10.0 | False | None | None | False | None | False | 2310.0 | 0 | 3043017 | 102819 | None | code60 | Supplying and flush mounting powder/galvanized coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/stone /c.c wall 8 way | Each | 274.05 | 274.05 | 12.0 | False | None | None | False | None | False | 3288.6 | 0 | 3043018 | 102819 | None | code61 | Supplying and flush mounting powder/galvanized coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/stone /c.c wall 10-12 way | Each | 334.95 | 334.95 | 4.0 | False | None | None | False | None | False | 1339.8 | 0 | 3043019 | 102819 | None | code62 | Supplying and flush mounting powder/galvanized coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/stone /c.c wall 16 way | Each | 381.15 | 381.15 | 8.0 | False | None | None | False | None | False | 3049.2 | 0 | 3043020 | 102819 | None | code63 | Supplying and fixing superior quality modular switch mounting poly carbonate plate with necessary supporting back plate with required nos. of machine screws, bolts, nuts etc., complete on the existing metal/PVC box. 1to 2 module | Each | 143.85 | 143.85 | 2.0 | False | None | None | False | None | False | 287.7 | 0 | 3043021 | 102819 | None | code64 | Supplying and fixing superior quality modular switch mounting poly carbonate plate with necessary supporting back plate with required nos. of machine screws, bolts, nuts etc., complete on the existing metal/PVC box. 4 module | Each | 183.75 | 183.75 | 2.0 | False | None | None | False | None | False | 367.5 | 0 | 3043022 | 102819 | None | code65 | Supplying and fixing superior quality modular switch mounting poly carbonate plate with necessary supporting back plate with required nos. of machine screws, bolts, nuts etc., complete on the existing metal/PVC box. 6 module | Each | 245.7 | 245.7 | 10.0 | False | None | None | False | None | False | 2457.0 | 0 | 3043023 | 102819 | None | code66 | Supplying and fixing superior quality modular switch mounting poly carbonate plate with necessary supporting back plate with required nos. of machine screws, bolts, nuts etc., complete on the existing metal/PVC box. 8 module | Each | 298.2 | 298.2 | 12.0 | False | None | None | False | None | False | 3578.4 | 0 | 3043024 | 102819 | None | code67 | Supplying and fixing superior quality modular switch mounting poly carbonate plate with necessary supporting back plate with required nos. of machine screws, bolts, nuts etc., complete on the existing metal/PVC box. 12 module | Each | 361.2 | 361.2 | 4.0 | False | None | None | False | None | False | 1444.8 | 0 | 3043025 | 102819 | None | code68 | Supplying and fixing superior quality modular switch mounting poly carbonate plate with necessary supporting back plate with required nos. of machine screws, bolts, nuts etc., complete on the existing metal/PVC box. 16 Module | Each | 416.85 | 416.85 | 8.0 | False | None | None | False | None | False | 3334.8 | 0 | 3043026 | 102819 | None | code69 | Supplying and fixing of modular switch & connected accessories on
existing modular switch plate as per IS 3854 and IS 1293 6 Amps one way switch | Each | 107.1 | 107.1 | 200.0 | False | None | None | False | None | False | 21420.0 | 0 | 3043027 | 102819 | None | code70 | Supplying and fixing of modular switch & connected accessories on
existing modular switch plate as per IS 3854 and IS 1293
6Amps 2 way switch | Each | 174.3 | 174.3 | 4.0 | False | None | None | False | None | False | 697.2 | 0 | 3043028 | 102819 | None | code71 | Supplying and fixing of modular switch & connected accessories on
existing modular switch plate as per IS 3854 and IS 1293
6Amps 3 way socket | Each | 179.55 | 179.55 | 30.0 | False | None | None | False | None | False | 5386.5 | 0 | 3043029 | 102819 | None | code72 | Supplying and fixing of modular switch & connected accessories on
existing modular switch plate as per IS 3854 and IS 1293
Stepped fan regulator two module | Each | 374.85 | 374.85 | 5.0 | False | None | None | False | None | False | 1874.25 | 0 | 3043030 | 102819 | None | code73 | Wiring for lighting or power circuit using one of FRLS PVC insulated 1100v grade,multis and copper with low conductor resistance single core wire in open or consealed system of wiring with specified IS-694:1990 & confirming to GTP Group 'A' material 1.5 Sqmm | Mtr | 27.3 | 27.3 | 600.0 | False | None | None | False | None | False | 16380.0 | 0 | 3043031 | 102819 | None | code74 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-
694:2010 2.5 Sqmm | Mtr | 44.1 | 44.1 | 1400.0 | False | None | None | False | None | False | 61740.0 | 0 | 3043032 | 102819 | None | code75 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-
694:2010 4 Sqmm | Mtr | 66.15 | 66.15 | 500.0 | False | None | None | False | None | False | 33075.0 | 0 | 3043033 | 102819 | None | code76 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.III - Double Door 6Way TP &N | Each | 5187.0 | 5187.0 | 3.0 | False | None | None | False | None | False | 15561.0 | 0 | 3043034 | 102819 | None | code77 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 amps SP | Each | 435.75 | 435.75 | 12.0 | False | None | None | False | None | False | 5229.0 | 0 | 3043035 | 102819 | None | code78 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 amps DP | Each | 775.95 | 775.95 | 8.0 | False | None | None | False | None | False | 6207.6 | 0 | 3043036 | 102819 | None | code79 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board.. 63 Amps 4 pole | Each | 5822.25 | 5822.25 | 3.0 | False | None | None | False | None | False | 17466.75 | 0 | 3043037 | 102819 | None | code80 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia
2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification
7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia | Nos | 3685.5 | 3685.5 | 3.0 | False | None | None | False | None | False | 11056.5 | 0 | 3043038 | 102819 | None | code81 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI Strip | Mtr | 134.4 | 134.4 | 100.0 | False | None | None | False | None | False | 13440.0 | 0 | 3043039 | 102819 | None | code82 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm Copper Strip | Mtr | 598.5 | 598.5 | 100.0 | False | None | None | False | None | False | 59850.0 | 0 | 3043040 | 102819 | None | code83 | Supplying of PVC Batten with integrated LED tube LED light fighting 1 x4'- 36/40 w with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. | Each | 1332.45 | 1332.45 | 80.0 | False | None | None | False | None | False | 106596.0 | 0 | 3043041 | 102819 | None | code84 | Extra for supplying 4mm thick white plastic plate and covering for junction boxes of size 110mm conduite using necessary machine screws. | No | 22.05 | 22.05 | 70.0 | False | None | None | False | None | False | 1543.5 | 0 | 3043042 | 102819 | None | code85 | Supplying & Fixing of 230 Volts 20/40 watts Fluorescent
Lamp holder | Each | 34.65 | 34.65 | 120.0 | False | None | None | False | None | False | 4158.0 | 0 | 3043043 | 102819 | None | code86 | Supplying and fixing Metal Fan Box with Round Hook | No | 122.85 | 122.85 | 5.0 | False | None | None | False | None | False | 614.25 | 0 | 3043044 | 102819 | None | code87 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts,50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular model | Each | 3133.2 | 3133.2 | 5.0 | False | None | None | False | None | False | 15666.0 | 0 | 3043045 | 102819 | None | code88 | Fixing all types and all capacities fluorecent/false ceiling/spot light/CFL fittings indoor on the wall / rafter / girders using 23/0.0076" twin twisted PVC insulated wires, required nos of round blocks and clamps (if required)a)On wall/ceiling/Rafters/Girders | Each | 128.1 | 128.1 | 80.0 | False | None | None | False | None | False | 10248.0 | 0 | 3043046 | 102819 | None | code89 | Fixing a ceiling/wall mounting fan of all capacities and all types to the existing S hook together with supplying and fixing a 5 amperes ceiling rose,necessary lenth of 23/0.0076 inch PVC insluted twisted copper wire and wiring completely. | Each | 179.55 | 179.55 | 5.0 | False | None | None | False | None | False | 897.75 | 0 | 3043047 | 102819 | None | code90 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth Vol-1 (pg no 8, I No 1.12) | Cum | 99.75 | 99.75 | 69.71 | False | None | None | False | None | False | 6953.5725 | 0 | 3043048 | 102819 | None | code91 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3m Vol-1 (pg no 8, I No 1.14.1) | Cum | 107.1 | 107.1 | 118.8 | False | None | None | False | None | False | 12723.48 | 0 | 3043049 | 102819 | None | code92 | Providing and laying in position Cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates Vol-1 (pg no 15, I No 2.1.3) | Cum | 6288.45 | 6288.45 | 9.9 | False | None | None | False | None | False | 62255.655 | 0 | 3043050 | 102819 | None | code93 | Providing and laying in position Cement concrete for all Foundation works. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including Additional for formwork, Centering & Scaffolding for Sl No 1 a: Foundation upto plinth Isolated As per Addendum-I in Volume-1 of page No.-111 (@8% of Finished Rate) Vol-1 (pg no 15, I No 2.2.3) | Cum | 7185.02 | 7185.02 | 28.51 | False | None | None | False | None | False | 204844.9202 | 0 | 3043051 | 102819 | None | code94 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including Additional for formwork, Centering & Scaffolding for Sl No 9: RCC Columns As per Addendum-I in Volume-1 of page No.-111 (@70% of Finished Rate) Vol-1 (pg no 16, I No 2.4.3) | Cum | 11309.76 | 11309.76 | 2.97 | False | None | None | False | None | False | 33589.9872 | 0 | 3043052 | 102819 | None | code95 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. Vol-1 (pg no 7, I No 1.9) | Cum | 279.3 | 279.3 | 118.8 | False | None | None | False | None | False | 33180.84 | 0 | 3043053 | 102819 | None | code96 | Providing and laying in position Cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. including Additional for formwork, Centering & Scaffolding for Sl No 9 : RCC Columns As per Addendum-I in Volume-1 of page No.-111 (@70% of Finished Rate) Ground Floor Vol-1 (pg no 16, I No 2.5.2) | Cum | 12214.76 | 12214.76 | 7.13 | False | None | None | False | None | False | 87091.2388 | 0 | 3043054 | 102819 | None | code97 | Providing and laying in position Cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. including Additional for formwork, Centering & Scaffolding for Sl No 1.a Plinth beam of buildings As per Addendum-I in Volume-1 of page No.-111 (@50% of Finished Rate) Ground Floor Vol-1 (pg no 16, I No 2.5.2) | Cum | 10777.73 | 10777.73 | 13.25 | False | None | None | False | None | False | 142804.9225 | 0 | 3043055 | 102819 | None | code98 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and
technical specification h.All other type of structutres Vol-1 (pg no 18, I No 2.11(h)) | Tonne | 81381.33 | 81381.33 | 5.04 | False | None | None | False | None | False | 410161.9032 | 0 | 3043056 | 102819 | None | code99 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Vol-2 (pg no 14, I No 6.8) | Cum | 8367.45 | 8367.45 | 52.99 | False | None | None | False | None | False | 443391.1755 | 0 | 3043057 | 102819 | None | code100 | Providing and laying in position Cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. y) Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates Vol-1 (pg no 16, I No 2.4.1) | Cum | 6724.2 | 6724.2 | 4.71 | False | None | None | False | None | False | 31670.982 | 0 | 3043058 | 102819 | None | code101 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Vol-2 (pg no 41, I No 8.2.1) | Sqm | 309.75 | 309.75 | 490.24 | False | None | None | False | None | False | 151851.84 | 0 | 3043059 | 102819 | None | code102 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth. Vol-2 (pg no 54, I No 8.80) | m | 69.3 | 69.3 | 500.0 | False | None | None | False | None | False | 34650.0 | 0 | 3043060 | 102819 | None | code103 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Vol-2 (pg no 46, I No 8.32) | Sqm | 163.8 | 163.8 | 490.24 | False | None | None | False | None | False | 80301.312 | 0 | 3043061 | 102819 | None | code104 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Vol-2 (pg no 47, I No 8.33.3) | Sqm | 145.95 | 145.95 | 10.0 | False | None | None | False | None | False | 1459.5 | 0 | 3043062 | 102819 | None | code105 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Vol-2 (pg no 82, I No 11.16.1) | Kg | 142.8 | 142.8 | 600.0 | False | None | None | False | None | False | 85680.0 | 0 | 3043063 | 102819 | None | code106 | Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 (v) For Grading -V Material Vol-3 (pg no 23, I No 4.2 B (V)) | Cum | 2476.95 | 2476.95 | 34.86 | False | None | None | False | None | False | 86346.477 | 0 | 3043064 | 102819 | None | code107 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course onwell prepared surface and compacting with vibratory roller to achieve the desired density. Vol-2 (pg no 26, I No 4.17) | Cum | 2686.95 | 2686.95 | 34.86 | False | None | None | False | None | False | 93667.077 | 0 | 3043065 | 102819 | None | code108 | Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. Vol-2 (pg no 63, I No 9.25) | Sqm | 840.0 | 840.0 | 348.55 | False | None | None | False | None | False | 292782.0 | 0 | 3043066 | 102819 | None | code109 | Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 300 x 250 x 100 mm Kerb Stone Vol-3 (pg no 74, I No 8.42.1) | m | 318.15 | 318.15 | 100.0 | False | None | None | False | None | False | 31815.0 | 0 | 3043067 | 102819 | None | code110 | Water purification plants: Providing, Installation and Commissioning of
automatic Water purification plant (RO+UF) with all accessories piping,
product water tank on single phase power supply as per the enclosed
detailed Technical Specifications including cost of material, loading
and unloading and as directed by the Engineer in charge. (Ref- detailed
specification enclosed seperatly). Note:- 1.The above rates mentioned
are only for the preparation of estimate purpose. 2. All items are to be of
BSI /NFS standards,with BSI / NFS mark . 3. Tenders to be invited for
procurement. 4. No direct payment should be made under any situation
or condition or on any account. 5. After commissioning of plant necessary
testing to be done for the satisfactory of Engineer Incharge. Note : Refer
the ANNEXURE : F for Detailed Specification of Each components For 50 LPH : Cabin Type Vol-5 (pg no 247, I No 21.1.2) | Each | 46200.0 | 46200.0 | 3.0 | False | None | None | False | None | False | 138600.0 | 0 | 3043068 | 102819 | None | code111 | Smart Surveillance System (CCTV): using PTZ & Fixed cameras, OFC monitoring system, HMI etc., as per specification
PTZ Camera Specification:
Lens type: Auto focus with Optical Zoom of 30x, Digital Zoom +10x
Pan Angle: 360 degree endless
Tilt Angle: 210 degree with e-flip or higher
Zoom : 30x Optical and 12x Digital
Mode :Day and Night
Image size: Full HD
Streaming: High speed
Weather Proof: IP 66 compliant
Network Protocol: TCP/IP should be compliant of any other protocol required.
Connectivity : Cat 6 / Optical fibre
Ethernet: 10Base-T/100Base-TX(RJ45)
Power source : both self powered and externally powered | No | 70719.6 | 70719.6 | 2.0 | False | None | None | False | None | False | 141439.2 | 0 | 3043069 | 102819 | None | code112 | Smart Surveillance System (CCTV): using Fixed cameras, OFC monitoring system, HMI etc., as per specification Fixed Camera Specifications: Lens type: Bi focal auto iris with 10xdigital zoom
Mode :Day/Night
Image size: 720x486 (NTSC)
Streaming: High speed
Weather Proof: IP 66 compliant
Network Protocol: TCP/IP should be compliant of any other protocol required.
Connectivity : Cat 6 / Optical fibre
Ethernet 10Base t/100Base TX(RJ45)
Power source : both self powered and externally powered | No | 12586.35 | 12586.35 | 2.0 | False | None | None | False | None | False | 25172.7 | 0 | 3043070 | 102819 | None | code113 | Industrial Grade PC with latest specification | No | 103672.8 | 103672.8 | 1.0 | False | None | None | False | None | False | 103672.8 | 0 | 3043071 | 102819 | None | code114 | HMI Monitor : 29" | No | 25918.2 | 25918.2 | 1.0 | False | None | None | False | None | False | 25918.2 | 0 | 3043072 | 102819 | None | code115 | Erection, Installation and commissioning of CCTV Surveillance system PTZ Camera | No | 1270.5 | 1270.5 | 2.0 | False | None | None | False | None | False | 2541.0 | 0 | 3043073 | 102819 | None | code116 | Erection, Installation and commissioning of CCTV Surveillance system Fixed Camera | No | 1270.5 | 1270.5 | 2.0 | False | None | None | False | None | False | 2541.0 | 0 | 3043074 | 102819 | None | code117 | Supplying and drawing UTP-CAT 6E LAN cable. | m | 39.9 | 39.9 | 400.0 | False | None | None | False | None | False | 15960.0 | 0 | 3043075 | 102819 | None | code118 | Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet
and out let pipes. SS Model with 100mm thick of 48Kg/M3 de Rock wool insulation with 22SWG Aluminium cladding. 300 L | Each | 73485.3 | 73485.3 | 3.0 | False | None | None | False | None | False | 220455.9 | 0 | 3043076 | 102819 | None | code119 | Supplying, installing, testing and commissioning of Diesel Generator set 62.5KVA/50kw with following specifications. Power rating as per standard reference condition as per-BS 5514/ISO 3046/ ISO 8528 & IS 1002/ISO 3046 Generator set specifications Engine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade), Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation Alternator: Alternator is suitable for operation at 1500 RPM, 415 V, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming to IS/IEC 60034-1. The Alternator is brush less type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have+/- 1.0% Voltage regulation (max) in static conditions- IP: 23 protections with insulation class F&H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lA for 'Load On' and 'Set Running', Instrument fuses duly wired and ferruled, MCCB of
suitable rating with overload and short circuit protections. | Set | 673124.55 | 673124.55 | 1.0 | False | None | None | False | None | False | 673124.55 | 0 | 3043077 | 102819 | None | code120 | Supply, Erection, testing and commissioning of AMF panel suitable for 62.5 KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for A 4 pole contactor for alternator
with thermal O/L relay,..... A 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, ....capacity bypass switch and frequency sensing, PCC 1301controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ kVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMF module by pass Mode, Battery charger unit with inbuilt Auto/Manual and Flat/Boost facility. The complete set shall have sufficient safety and adhere to NEC, NBC 2016, IEC, CPWD specifications, PCB norms and KSGEI Acts and Rules. | Each | 81656.4 | 81656.4 | 1.0 | False | None | None | False | None | False | 81656.4 | 0 |
|