createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1710328485874
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee3820.00
emd230000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose28-03-2024 16:00:00
tenderQueryClose21-03-2024 16:00:00
technicalBidOpen30-03-2024 16:00:00
publishedDate13-03-2024 19:24:21
publishedByPostKHB_EE2_CO_BNG
publishedByUserKPE11678 - LOKESHBABU C G
bidValidityPeriod180
noOfCalls1
preBidMeetingDate22-03-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonLokesh Babu C G
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08022273511
mobileNumber8022273511
tenderSupplierListNone
tenderSchedule
createdTs1710328486001
version6
createdDateNone
modifiedDateNone
tenderNumberKHB/2023-24/BD/WORK_INDENT211
titleConstruction of College Building Additional Classrooms Library Laboratory & other infrastructure works for Government First Grade College in Hangal & Ranebennur at Haveri District Under RUSA 2
descriptionConstruction of College Building Additional Classrooms Library Laboratory & other infrastructure works for Government First Grade College in Hangal & Ranebennur at Haveri District Under RUSA 2
categoryWORKS
categoryTextWorks
ecv15242830.98
deptNameKarnataka Housing Board
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location5488
locationNameKHB Central Office Bengaluru
provisionalAmount15242831.0
groupOverheadTotalNone
fileNumber87/2020-21
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17103284860000NoneNoneBuildingsGovernment First Grade College in Hangal at Haveri District Under RUSA 27644253.69
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3041543102778Nonecode01Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. In area of light jungle -- vol -3- 7 -- 2.4(i)ASqm1178.11178.1900.0FalseNoneNoneFalseNoneFalse1060290.00
3041544102778Nonecode02Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m -- vol -1- 8 -- 1.14.1Cum107.1107.1249.51FalseNoneNoneFalseNoneFalse26722.5210
3041545102778Nonecode03Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m ----In ordinary/soft rock without blasting upto 1.5 m depth -- vol -1- 8 -- 1.14.1Cum381.15381.1571.29FalseNoneNoneFalseNoneFalse27172.18350
3041546102778Nonecode04Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m ----In Hard Rock ( requiring blasting) Depth upto 1.50m -- vol -1- 8 -- 1.16.1Cum581.7581.735.64FalseNoneNoneFalseNoneFalse20731.7880
3041547102778Nonecode05Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. -- vol -2 - 4.1Sqm123.9123.9468.62FalseNoneNoneFalseNoneFalse58062.0180
3041548102778Nonecode06Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. -- vol -1- 7 -- 1.8Cum497.7497.7356.93FalseNoneNoneFalseNoneFalse177644.0610
3041549102778Nonecode07Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. -- vol -1- 7 -- 1.90Cum279.3279.3249.51FalseNoneNoneFalseNoneFalse69688.1430
3041550102778Nonecode08Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm and down size graded crushed coarse aggregates -- vol -1- 1 -- 2.1.3Cum6288.456288.4528.59FalseNoneNoneFalseNoneFalse179786.78550
3041551102778Nonecode09Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm and down size graded crushed coarse aggregates -- vol -1- 1 -- 2.1.3Cum6288.456288.450.81FalseNoneNoneFalseNoneFalse5093.64450
3041552102778Nonecode10Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm and down size graded crushed coarse aggregates -- vol -1- 1 -- 2.1.3Cum6414.226414.222.59FalseNoneNoneFalseNoneFalse16612.82980
3041553102778Nonecode11Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates -- vol -1- 1 -- 2.2.1Cum10034.0510034.0515.98FalseNoneNoneFalseNoneFalse160344.1190
3041554102778Nonecode12Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in ayers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) -- vol -1- 17 -- 2.5.2Cum10777.7310777.7314.73FalseNoneNoneFalseNoneFalse158755.96290
3041555102778Nonecode13Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in ayers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) -- vol -1- 17 -- 2.5.2Cum12214.7612214.763.11FalseNoneNoneFalseNoneFalse37987.90360
3041556102778Nonecode14Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in ayers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) -- vol -1- 17 -- 2.5.2Cum12214.7612214.7611.93FalseNoneNoneFalseNoneFalse145722.08680
3041557102778Nonecode15Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in ayers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) -- vol -1- 17 -- 2.5.2Cum11496.2411496.2412.01FalseNoneNoneFalseNoneFalse138069.84240
3041558102778Nonecode16Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in ayers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) -- vol -1- 17 -- 2.5.2Cum11496.2411496.2422.39FalseNoneNoneFalseNoneFalse257400.81360
3041559102778Nonecode17Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in ayers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) -- vol -1- 17 -- 2.5.2Cum10777.7310777.7335.57FalseNoneNoneFalseNoneFalse383363.85610
3041560102778Nonecode18Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in ayers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) -- vol -1- 17 -- 2.5.2Cum11496.2411496.244.27FalseNoneNoneFalseNoneFalse49088.94480
3041561102778Nonecode19Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in ayers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) -- vol -1- 17 -- 2.5.2Cum11639.9411639.940.82FalseNoneNoneFalseNoneFalse9544.75080
3041562102778Nonecode20Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates -- vol -1- 17 -- 2.5.2Cum10921.4310921.431.67FalseNoneNoneFalseNoneFalse18238.78810
3041563102778Nonecode21Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification -- vol -2- 8 -- 2.11aTonne93929.8593929.8514.63FalseNoneNoneFalseNoneFalse1374193.70550
3041564102778Nonecode22Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification -- vol -2- 8 -- 2.11aTonne93929.8593929.850.68FalseNoneNoneFalseNoneFalse63872.2980
3041565102778Nonecode23Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) -- vol -2- 9 -- 5.4Cum6708.456708.455.85FalseNoneNoneFalseNoneFalse39244.43250
3041566102778Nonecode24Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. -- vol -2- 17 -- 6.3Sqm1375.51375.5154.01FalseNoneNoneFalseNoneFalse211840.7550
3041567102778Nonecode25Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. -- vol -2- 17 -- 6.3Sqm1403.011403.0153.94FalseNoneNoneFalseNoneFalse75678.35940
3041568102778Nonecode26Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. -- vol -2- 17 -- 6.3Sqm1403.011403.0145.83FalseNoneNoneFalseNoneFalse64299.94830
3041569102778Nonecode27Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. -- vol -2- 17 -- 6.3Sqm1159.21159.27.5FalseNoneNoneFalseNoneFalse8694.00
3041570102778Nonecode28Providing Teak wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. -- vol -2- 99 -- 12.1Cum128518.95128518.950.19FalseNoneNoneFalseNoneFalse24418.60050
3041571102778Nonecode29Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. -- vol -2- 99 -- 12.13.1Cum103755.75103755.750.44FalseNoneNoneFalseNoneFalse45652.530
3041572102778Nonecode30Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. -- vol -2 -- 11.5.1Sqm4795.944795.946.0FalseNoneNoneFalseNoneFalse28775.640
3041573102778Nonecode31Providing and fixing in position Teak wood fully panelled shutters for windows with stiles and rails of 35mm. thick, 75mm wide in two halves with panels of 25mm thick including cost of materials, labour charges, usage charges complete as per specifications. (excluding cost of fixtures) -- vol -2- 101 -- 12.22Sqm7363.657363.654.8FalseNoneNoneFalseNoneFalse35345.520
3041574102778Nonecode32Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial -- vol -2- 106 -- 12.57.6Sqm3488.13488.18.64FalseNoneNoneFalseNoneFalse30137.1840
3041575102778Nonecode33Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. -- vol -2- 105 -- 12.54Sqm333.9333.914.4FalseNoneNoneFalseNoneFalse4808.160
3041576102778Nonecode34Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges -do- with both side prelam -- vol -2- 106 -- 12.55.1Sqm2484.32484.31.8FalseNoneNoneFalseNoneFalse4471.740
3041577102778Nonecode35Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications -- vol -2- 105Nos1066.81066.85.0FalseNoneNoneFalseNoneFalse5334.00
3041578102778Nonecode36Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. -- vol -2- 107 -- 12.58Nos126.0126.05.0FalseNoneNoneFalseNoneFalse630.00
3041579102778Nonecode37Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. -- vol -2- 107 -- 12.59Nos1169.71169.75.0FalseNoneNoneFalseNoneFalse5848.50
3041580102778Nonecode38Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. -- vol -2- 107 -- 12.60Nos1104.61104.65.0FalseNoneNoneFalseNoneFalse5523.00
3041581102778Nonecode39Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete -- vol -2- 107 -- 12.62Nos248.85248.855.0FalseNoneNoneFalseNoneFalse1244.250
3041582102778Nonecode40Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete -- vol -2- 107 -- 12.63Nos136.5136.55.0FalseNoneNoneFalseNoneFalse682.50
3041583102778Nonecode41Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) -- vol -2- 112 -- 12.89Sqm6878.556878.5524.3FalseNoneNoneFalseNoneFalse167148.7650
3041584102778Nonecode42Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) -- vol -2- 110 -- 12.85Sqm6004.956004.958.91FalseNoneNoneFalseNoneFalse53504.10450
3041585102778Nonecode43Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. -- vol -2- 41 -- 8.4.1Sqm339.15339.15244.13FalseNoneNoneFalseNoneFalse82796.68950
3041586102778Nonecode44Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. -- vol -2- 42 -- 8.2.1Sqm309.75309.75362.55FalseNoneNoneFalseNoneFalse112299.86250
3041587102778Nonecode45Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. -- vol -2- 42 -- 8.2.1Sqm315.95315.95122.91FalseNoneNoneFalseNoneFalse38833.41450
3041588102778Nonecode46Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. -- vol -2- 50 -- 8.51Sqm105.0105.0871.05FalseNoneNoneFalseNoneFalse91460.250
3041589102778Nonecode47Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Out side) -- vol -2- 42 -- 8.8Sqm389.55389.55204.72FalseNoneNoneFalseNoneFalse79748.6760
3041590102778Nonecode48Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Out side) -- vol -2- 42 -- 8.8Sqm397.34397.34140.15FalseNoneNoneFalseNoneFalse55687.2010
3041591102778Nonecode49Chicken Mesh - A-18 - SL.NO. 203 -- vol-2Sqm12.8512.85200.0FalseNoneNoneFalseNoneFalse2570.00
3041592102778Nonecode50Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge -- vol -2- 44 -- 8.19.1Sqm267.75267.7511.7FalseNoneNoneFalseNoneFalse3132.6750
3041593102778Nonecode51Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. -- vol -2- 23 -- 7.18Cum2160.212160.213.29FalseNoneNoneFalseNoneFalse7107.09090
3041594102778Nonecode52Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. -- vol -2- 46 -- 8.19.1Sqm165.9165.9871.05FalseNoneNoneFalseNoneFalse144507.1950
3041595102778Nonecode53Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paer smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge -- vol -2- 46 -- 8.3Sqm182.7182.7466.77FalseNoneNoneFalseNoneFalse85278.8790
3041596102778Nonecode54Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. -- vol -2 -- 8.34.1Sqm55.6555.6524.62FalseNoneNoneFalseNoneFalse1370.1030
3041597102778Nonecode55Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. -- vol -2- 61 -- 9.17.2Sqm1233.751233.7537.84FalseNoneNoneFalseNoneFalse46685.10
3041598102778Nonecode56Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. -- vol -2- 63 -- 9.24Sqm2994.62994.6101.13FalseNoneNoneFalseNoneFalse302843.8980
3041599102778Nonecode57Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. -- vol -2- 60 -- 9.10Sqm933.45933.451.08FalseNoneNoneFalseNoneFalse1008.1260
3041600102778Nonecode58Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. -- vol -2- 65 -- 9.38Sqm1461.61461.65.18FalseNoneNoneFalseNoneFalse7571.0880
3041601102778Nonecode59Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding -- vol -2- 85 -- 11.34AKg176.4176.4597.78FalseNoneNoneFalseNoneFalse105448.3920
3041602102778Nonecode60Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding -- vol -2- 85 -- 11.34AKg179.93179.93259.2FalseNoneNoneFalseNoneFalse46637.8560
3041603102778Nonecode61Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. -- vol -2- 83 -- 11.28Kg593.25593.2591.8FalseNoneNoneFalseNoneFalse54460.350
3041604102778Nonecode62Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. -- vol -2- 133 -- 9.32Sqm857.85857.85255.0FalseNoneNoneFalseNoneFalse218751.750
3041605102778Nonecode63Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. -- vol -2- 133 -- 9.32 S FSqm875.01875.0121.0FalseNoneNoneFalseNoneFalse18375.210
3041606102778Nonecode64Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. -- vol -2- 75 -- 11.5.1Sqm4795.944795.941.89FalseNoneNoneFalseNoneFalse9064.32660
3041607102778Nonecode65Providing and fixing 1 mm thick M.S. sheet sliding-shutters, with frame and diagonal braces of 40x40x6 mm angle iron, 3 mm M.S. gusset plates at the junctions and corners, 25 mm dia pulley, 40x40x6 mm angle and T- iron guide at the top and bottom respectively, including applying a priming coat of approved steel primer including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. -- vol -2- 75 -- 11.4Sqm5591.695591.695.1FalseNoneNoneFalseNoneFalse28517.6190
3041608102778Nonecode66Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm -- vol -2 -- 11.31Nos1281.01281.01.0FalseNoneNoneFalseNoneFalse1281.00
3041609102778Nonecode67Providing and placing on terrace, polythylene water storage tanks as per IS 12701 :1996 with manhole lid and suitable locking arrangements,making holes of suitable diameter for inlet,outlet and over flow pipes, including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications -- vol -2 -- 14.32.2Ltr6.36.320000.0FalseNoneNoneFalseNoneFalse126000.00
3041610102778Nonecode68Earth work excavation for Foundation by manual means for all Buildings, Bridges, Retaining walls, Abutment Piers and such similar works as per drawing and technical Specifications, including setting out, providing shoring & strutting,barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m -- Vol 1- A(58) -- 1.6.2Cum124.95124.955.0FalseNoneNoneFalseNoneFalse624.750
3041611102778Nonecode69Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. Vol 1- A(60) -- 1.10Cum168.0168.05.0FalseNoneNoneFalseNoneFalse840.00
3041612102778Nonecode70Providing and fixing 3 layer PP-R (Poly Propylene Random Copolymer) pipes confirming to IS.15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply, including all PP-R plain and brass threaded polypropylene random fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer-In- Charge.---- Poly Propylene Random Co-ploymer (PPR) pipe with fitting SDR --7.4 -16 mm Outer dia -- Vol 5 Page 34 -- 2.62 --5894m199.5199.550.0FalseNoneNoneFalseNoneFalse9975.00
3041613102778Nonecode71Providing and fixing 3 layer PP-R (Poly Propylene Random Copolymer) pipes confirming to IS.15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply, including all PP-R plain and brass threaded polypropylene random fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer-In- Charge.---- Poly Propylene Random Co-ploymer (PPR) pipe with fitting SDR -- 7.4 -20 mm Outer dia -- Vol 5 Page 34 -- 2.62 -- 5895m215.25215.2545.0FalseNoneNoneFalseNoneFalse9686.250
3041614102778Nonecode72Providing and fixing 3 layer PP-R (Poly Propylene Random Copolymer) pipes confirming to IS.15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply, including all PP-R plain and brass threaded polypropylene random fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer-In- Charge.---32mm nominal dia Pipes -- Vol 5 Page 34 -- 2.62 -- 5897m362.25362.2510.0FalseNoneNoneFalseNoneFalse3622.50
3041615102778Nonecode73Providing and fixing 3 layer PP-R (Poly Propylene Random Copolymer) pipes confirming to IS.15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply, including all PP-R plain and brass threaded polypropylene random fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer-In- Charge.---40mm nominal dia Pipes -- Vol 5 Page 34 -- 2.62 -- 5898m527.1527.112.0FalseNoneNoneFalseNoneFalse6325.20
3041616102778Nonecode74Providing and fixing 3 layer PP-R (Poly Propylene Random Copolymer) pipes confirming to IS.15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply, including all PP-R plain and brass threaded polypropylene random fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer-In- Charge.----50mm -- Vol 5 Page 34 -- 2.62 -- 5899m699.3699.375.0FalseNoneNoneFalseNoneFalse52447.50
3041617102778Nonecode75Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:Nos2410.82410.82.0FalseNoneNoneFalseNoneFalse4821.60
3041618102778Nonecode76Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.Nos850.5850.52.0FalseNoneNoneFalseNoneFalse1701.00
3041619102778Nonecode77Providing and fixing PTMT pillar cock of approved quality and colour. 15 mm nominal bore, 125 mm long foam flow, weighing not less than 120 gmsNos329.7329.72.0FalseNoneNoneFalseNoneFalse659.40
3041620102778Nonecode78Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : -- Vol 2 - 123 -- 14.2.1Nos5079.95079.91.0FalseNoneNoneFalseNoneFalse5079.90
3041621102778Nonecode79Providing and fixing unplasticised PVC connection pipe with brass unions : Vol 2 - 123 -- 13.8Nos115.5115.51.0FalseNoneNoneFalseNoneFalse115.50
3041622102778Nonecode80Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Vol 2 - 123 -- 14.4Nos7123.27123.21.0FalseNoneNoneFalseNoneFalse7123.20
3041623102778Nonecode81Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. Vol 2 - 123-- 14.40.2Unit520.8520.81.0FalseNoneNoneFalseNoneFalse520.80
3041624102778Nonecode82Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : :20mm -- Vol 2 - 115 -- 13.4Nos320.25320.251.0FalseNoneNoneFalseNoneFalse320.250
3041625102778Nonecode83Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 25mm dia -- Vol 2 - 115 -- 13.4.1Nos576.45576.452.0FalseNoneNoneFalseNoneFalse1152.90
3041626102778Nonecode84Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 50mm -- Vol 2 - 115 -- 13.4.4Nos897.75897.751.0FalseNoneNoneFalseNoneFalse897.750
3041627102778Nonecode85Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. Vol 2 - 118 -- 13.23Nos259.35259.352.0FalseNoneNoneFalseNoneFalse518.70
3041628102778Nonecode86Providing and fixing gun metal non- return valve of approved quality (screwed end) : Vol 2 - 115 -- 13.6.4.2Nos1604.41604.41.0FalseNoneNoneFalseNoneFalse1604.40
3041629102778Nonecode87Constructing brick masonry chamber of internal dimension 450x300mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover..(Gully trap) -- Vol 5 Page 188 --- 16.8Nos5030.555030.556.0FalseNoneNoneFalseNoneFalse30183.30
3041630102778Nonecode88Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. BWSSB 21-22 - 168 -- T130BNos5726.75726.71.0FalseNoneNoneFalseNoneFalse5726.70
3041631102778Nonecode89Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 32mm dia., 10 kg/sqcm & class 5 -- Vol 5 Page 134 --M010Bm70.3570.3530.0FalseNoneNoneFalseNoneFalse2110.50
3041632102778Nonecode90Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 50mm dia., 6 kg/sqcm & class 5 Vol 5 Page 134 --M010Cm106.05106.0524.0FalseNoneNoneFalseNoneFalse2545.20
3041633102778Nonecode91Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 75mm dia., 6 kg/sqcm & class 3 -- Vol 5 Page 134 -- M010Em231.0231.060.0FalseNoneNoneFalseNoneFalse13860.00
3041634102778Nonecode92Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 --- Vol 5 Page 134 -- M010Gm431.55431.55100.0FalseNoneNoneFalseNoneFalse43155.00
3041635102778Nonecode93Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 160mm dia., 6 kg/sqcm & class 3 -- Vol 5 Page 134 -- M010Im648.9648.92.0FalseNoneNoneFalseNoneFalse1297.80
3041636102778Nonecode94Internal Wiring - Point wiring using Copper wire with switch Supplying & wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5sqmm (Phase & Neutral) & 1x1.0sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.-------Short point upto 3Mtr from tapping point to outlet via switch. -- PAGE - 2 - 2.2.1Nos269.0269.020.0FalseNoneNoneFalseNoneFalse5380.00
3041637102778Nonecode95Internal Wiring - Point wiring using Copper wire with switch Supplying & wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5sqmm (Phase & Neutral) & 1x1.0sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.--------Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switch. -- PAGE - 2 - 2.2.2Nos379.0379.09.0FalseNoneNoneFalseNoneFalse3411.00
3041638102778Nonecode96Internal Wiring - Point wiring using Copper wire with switch Supplying & wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5sqmm (Phase & Neutral) & 1x1.0sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.---------Long point above 6Mtr upto 10Mtr from tapping point to outlet via switch. -- PAGE - 2 - 2.2.3Nos555.0555.013.0FalseNoneNoneFalseNoneFalse7215.00
3041639102778Nonecode97Two outlet in a row, above 3Mtr upto 6Mtr from tapping point to outlet via switches. -- PAGE - 2 - 2.2.4Nos677.0677.02.0FalseNoneNoneFalseNoneFalse1354.00
3041640102778Nonecode98Supplying heavy gauge PVC conduit pipe 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary.------19/20mm dia 2mm thick -- PAGE - 2 - 1.2.1m66.066.075.0FalseNoneNoneFalseNoneFalse4950.00
3041641102778Nonecode99Supplying heavy gauge PVC conduit pipe 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary.---25mm dia 2mm thick -- PAGE - 2 - 1.2.2m78.078.0250.0FalseNoneNoneFalseNoneFalse19500.00
3041642102778Nonecode100Supplying heavy gauge PVC conduit pipe 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary.---32mm dia 2.5mm thick -- PAGE - 2 - 1.2.3m103.0103.050.0FalseNoneNoneFalseNoneFalse5150.00
3041643102778Nonecode101Supplying heavy gauge PVC Conduit Pipe 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.----19/20mm dia 2mm thick -- PAGE - 2 - 1.3.1m68.068.025.0FalseNoneNoneFalseNoneFalse1700.00
3041644102778Nonecode102Supplying heavy gauge PVC Conduit Pipe 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.----25mm dia 2mm thick -- PAGE - 2 - 1.3.2m79.079.075.0FalseNoneNoneFalseNoneFalse5925.00
3041645102778Nonecode103Supplying heavy gauge PVC Conduit Pipe 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.---32mm dia 2.5mm thick -- PAGE - 2 - 1.3.3m99.099.020.0FalseNoneNoneFalseNoneFalse1980.00
3041646102778Nonecode104Supplying and fixing PVC/metal conduit Deep junction box---19/20mm deep junction box -- PAGE - 2 - 1.5.1Nos49.049.020.0FalseNoneNoneFalseNoneFalse980.00
3041647102778Nonecode105Supplying and fixing PVC/metal conduit Deep junction box---25mm deep junction box -- PAGE - 2 - 1.5.2Nos56.056.025.0FalseNoneNoneFalseNoneFalse1400.00
3041648102778Nonecode106Supplying and fixing PVC/metal conduit Deep junction box---32mm deep junction box -- PAGE - 2 - 1.5.3Nos61.061.010.0FalseNoneNoneFalseNoneFalse610.00
3041649102778Nonecode107Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300mm …. etc. as required.---20mm -- PAGE - 3 - 1.8.1m28.028.025.0FalseNoneNoneFalseNoneFalse700.00
3041650102778Nonecode108Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300mm …. etc. as required.---25mm -- PAGE - 3 - 1.8.2m35.035.075.0FalseNoneNoneFalseNoneFalse2625.00
3041651102778Nonecode109Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300mm …. etc. as required.---32mm -- PAGE - 3 - 1.8.3m43.043.020.0FalseNoneNoneFalseNoneFalse860.00
3041652102778Nonecode110Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cuttingin Brick/Stone/C.C wall.--1-3Way -- PAGE - 8 - 3.4.1Nos138.0138.010.0FalseNoneNoneFalseNoneFalse1380.00
3041653102778Nonecode111Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cuttingin Brick/Stone/C.C wall.--4-5Way -- PAGE - 8 - 3.4.3Nos177.0177.05.0FalseNoneNoneFalseNoneFalse885.00
3041654102778Nonecode112Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cuttingin Brick/Stone/C.C wall.--6Way -- PAGE - 8 - 3.4.4Nos220.0220.05.0FalseNoneNoneFalseNoneFalse1100.00
3041655102778Nonecode113Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cuttingin Brick/Stone/C.C wall.--8Way -- PAGE - 8 - 3.4.5Nos261.0261.035.0FalseNoneNoneFalseNoneFalse9135.00
3041656102778Nonecode114Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cuttingin Brick/Stone/C.C wall.--10-12Way -- PAGE - 8 - 3.4.6Nos319.0319.010.0FalseNoneNoneFalseNoneFalse3190.00
3041657102778Nonecode115Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.--1 to 3 Module -- PAGE - 8 - 3.5.2Nos161.0161.010.0FalseNoneNoneFalseNoneFalse1610.00
3041658102778Nonecode116Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.--4 Module -- PAGE - 8 - 3.5.3Nos175.0175.05.0FalseNoneNoneFalseNoneFalse875.00
3041659102778Nonecode117Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.--6 Module -- PAGE - 8 - 3.5.4Nos234.0234.05.0FalseNoneNoneFalseNoneFalse1170.00
3041660102778Nonecode118Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.--8 Module -- PAGE - 8 - 3.5.5Nos284.0284.035.0FalseNoneNoneFalseNoneFalse9940.00
3041661102778Nonecode119Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.--10 -12 Module -- PAGE - 8 - 3.5.6Nos344.0344.010.0FalseNoneNoneFalseNoneFalse3440.00
3041662102778Nonecode120Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.--6Amps one way Switch -- PAGE - 9 - 3.6.1Nos102.0102.0130.0FalseNoneNoneFalseNoneFalse13260.00
3041663102778Nonecode121Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.--6Amps Two way Switch -- PAGE - 9 - 3.6.2Nos166.0166.02.0FalseNoneNoneFalseNoneFalse332.00
3041664102778Nonecode122Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.--6Amps 3way socket -- PAGE - 9 - 3.6.3Nos171.0171.085.0FalseNoneNoneFalseNoneFalse14535.00
3041665102778Nonecode123Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.--Stepped Fan Regulator -- PAGE - 9 - 3.6.4Nos357.0357.014.0FalseNoneNoneFalseNoneFalse4998.00
3041666102778Nonecode124Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.--16Amps one way switch -- PAGE - 9 - 3.6.8Nos180.0180.08.0FalseNoneNoneFalseNoneFalse1440.00
3041667102778Nonecode125Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.--6/16Amps universal socket -- PAGE - 9 - 3.6.11Nos236.0236.08.0FalseNoneNoneFalseNoneFalse1888.00
3041668102778Nonecode126Supplying and fixing of metal clad industrial plugs and sockets.---20 Amps 2pole+earth 250V PLUG -- PAGE - 9 - 3.13.2Nos548.08548.081.0FalseNoneNoneFalseNoneFalse548.080
3041669102778Nonecode127Supplying and fixing of metal clad industrial plugs and sockets.---20 Amps 2pole+earth 250V SOCKET -- PAGE - 9 - 3.13.6Nos667.04667.041.0FalseNoneNoneFalseNoneFalse667.040
3041670102778Nonecode128Supplying and fixing of metal clad industrial plugs and sockets.---30 Amps 3pole+earth 440V PLUG -- PAGE - 9 - 3.13.4Nos609.86609.861.0FalseNoneNoneFalseNoneFalse609.860
3041671102778Nonecode129Supplying and fixing of metal clad industrial plugs and sockets.---30 Amps 3pole+earth 440V SOCKET -- PAGE - 9 - 3.13.8Nos827.82827.821.0FalseNoneNoneFalseNoneFalse827.820
3041672102778Nonecode130Supplying And Fixing M.S Rafter Clamp Set made out of M.S Flat & 14mm M.S rod. -- PAGE - 4 - 1.12Nos160.0160.014.0FalseNoneNoneFalseNoneFalse2240.00
3041673102778Nonecode131Supplying And Fixing M.S Rafter Clamp Set made out of M.S Flat & 14mm M.S rod. --- Supplying And Fixing Metal Fan Box with Round Hook. -- PAGE - 4 - 1.13Nos117.0117.014.0FalseNoneNoneFalseNoneFalse1638.00
3041674102778Nonecode132Supplying And Fixing M.S Rafter Clamp Set made out of M.S Flat & 14mm M.S rod.----Extra length of GI pipe of class B 19mm dia for down rod. -- PAGE - 57 - 13.12Nos197.0197.014.0FalseNoneNoneFalseNoneFalse2758.00
3041675102778Nonecode133Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. ----1.5 sqmm -- PAGE - 5 - 2.3.2m26.026.0200.0FalseNoneNoneFalseNoneFalse5200.00
3041676102778Nonecode134Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. ---- 2.5 sqmm -- PAGE - 5 - 2.3.3m42.042.0650.0FalseNoneNoneFalseNoneFalse27300.00
3041677102778Nonecode135Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. --- 4.0 sqmm -- PAGE - 5 - 2.3.4m63.063.0850.0FalseNoneNoneFalseNoneFalse53550.00
3041678102778Nonecode136Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.--- 6.0 sqmm -- PAGE - 5 - 2.3.5m92.092.040.0FalseNoneNoneFalseNoneFalse3680.00
3041679102778Nonecode137Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.---10.0 sqmm -- PAGE - 5 - 2.3.6m167.0167.080.0FalseNoneNoneFalseNoneFalse13360.00
3041680102778Nonecode138Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB 1 ph/3 ph/single door with powder coated painting. Made out of 14SWG MS enclosure.---8Way SP&N -- PAGE - 18 - 5.19.8Nos1854.01854.01.0FalseNoneNoneFalseNoneFalse1854.00
3041681102778Nonecode139Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB 1 ph/3 ph/single door with powder coated painting. Made out of 14SWG MS enclosure.----4Way TP&N -- PAGE - 18 - 5.19.11Nos4038.04038.03.0FalseNoneNoneFalseNoneFalse12114.00
3041682102778Nonecode140Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V up to 300mA sensitivity on existing wood/panel board.---32-40 Amps 2 pole -- PAGE - 13 - 5.20.2Nos2652.02652.01.0FalseNoneNoneFalseNoneFalse2652.00
3041683102778Nonecode141Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V up to 300mA sensitivity on existing wood/panel board.---32-40 Amps 4 pole -- PAGE - 13 - 5.20.3Nos2826.02826.02.0FalseNoneNoneFalseNoneFalse5652.00
3041684102778Nonecode142Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.---6-32Amps SP -- PAGE - 17 - 5.18.1Nos415.0415.030.0FalseNoneNoneFalseNoneFalse12450.00
3041685102778Nonecode143Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.---6-32 Amps DP -- PAGE - 17 - 5.18.4Nos739.0739.02.0FalseNoneNoneFalseNoneFalse1478.00
3041686102778Nonecode144Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.---40 Amps TPN -- PAGE - 17 - 5.18.8Nos3044.03044.04.0FalseNoneNoneFalseNoneFalse12176.00
3041687102778Nonecode145Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.----50-63Amps TPN -- PAGE - 17 - 5.18.9Nos3088.03088.01.0FalseNoneNoneFalseNoneFalse3088.00
3041688102778Nonecode146Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. PAGE - 17 - 54.04Nos2253.02253.03.0FalseNoneNoneFalseNoneFalse6759.00
3041689102778Nonecode147Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.--- 25x6mm GI strip -- PAGE - 40 - 6.3.1m115.0115.050.0FalseNoneNoneFalseNoneFalse5750.00
3041690102778Nonecode148Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.---25x6mm Copper strip PAGE - 40 - 6.3.7m958.0958.020.0FalseNoneNoneFalseNoneFalse19160.00
3041691102778Nonecode149Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.---600x600x3mm Copper plate PAGE - 40 - 6.3.10Nos6900.06900.01.0FalseNoneNoneFalseNoneFalse6900.00
3041692102778Nonecode150Supplying of 4feet - PVC Batten with integrated LED tube with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. -- LED light fighting 2 x 4'- 20/22 W -- PAGE - 43 - 11.3.3Nos1269.01269.025.0FalseNoneNoneFalseNoneFalse31725.00
3041693102778Nonecode151Supply of round/square recess/surface mounted rolling type LED Down light with GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition -- LED square or round down light 15-18W -- PAGE - 44 - 11.5.3Nos1324.01324.010.0FalseNoneNoneFalseNoneFalse13240.00
3041694102778Nonecode152Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. -- PAGE - 30 - 6.1Nos1492.01492.02.0FalseNoneNoneFalseNoneFalse2984.00
3041695102778Nonecode153Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. -- 48" Sweep (1200mm) Regular model -- PAGE - 30 - 6.3.1Nos2984.02984.014.0FalseNoneNoneFalseNoneFalse41776.00
3041696102778Nonecode154Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. -- PAGE - 56 - 13.7.1Nos122.0122.035.0FalseNoneNoneFalseNoneFalse4270.00
3041697102778Nonecode155Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. -- PAGE - 57 - 13.10Nos171.0171.014.0FalseNoneNoneFalseNoneFalse2394.00
3041698102778Nonecode156Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 amps. ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire. -- PAGE - 57 - 13.14Nos492.0492.02.0FalseNoneNoneFalseNoneFalse984.00
3041699102778Nonecode157Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975. 3.5 core x 25 sqmm -- PAGE-9-32.09m208.67208.67100.0FalseNoneNoneFalseNoneFalse20867.00
3041700102778Nonecode158Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required. -- PAGE-9-31.06 -- 25 sqmm to 75 sqmmm23.6523.65100.0FalseNoneNoneFalseNoneFalse2365.00
3041701102778Nonecode159Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7)--In soil (ordinary) -- PAGE-8-29.01m260.0260.075.0FalseNoneNoneFalseNoneFalse19500.00
3041702102778Nonecode160Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7)--In soil (hard) -- PAGE-8-29.03m389.0389.025.0FalseNoneNoneFalseNoneFalse9725.00
3041703102778Nonecode161Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable. -- PAGE-41-6.7m100.0100.075.0FalseNoneNoneFalseNoneFalse7500.00
3041704102778Nonecode162Providing and laying in position 100mm dia stone ware pipe in existing trench. -- PAGE-41-6.8m215.0215.025.0FalseNoneNoneFalseNoneFalse5375.00
3041705102778Nonecode163Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) -- PAGE-42-6.11.2 -- 25mm dia (25sqmm)Nos84.084.02.0FalseNoneNoneFalseNoneFalse168.00
3041706102778Nonecode164Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. -- 25 sqmm Long Barrel --PAGE-43-6.17.7Nos20.020.08.0FalseNoneNoneFalseNoneFalse160.00
3041707102778Nonecode165Providing and fixing Testing and commissioning of CP Health faucet consisting of 1 No. 15mm dia CP Angle cock with wall flage.PVC flexible tube of 1m long tube with end nuts. Hand operated spray unit (instent type)CP Crutch etc, complete as directed by the Engineer in charge.Nos1397.01397.01.0FalseNoneNoneFalseNoneFalse1397.00
3041708102778Nonecode166Provoding & fixing testing and commissioning u PVC multi inlet floor trap conforming to IS 13592 with required P C support placed to required level as per site condition complete. 110mm dia inlet 75mm dia outlet , Make: PRINCE / ASHIRWAD / SUPREME / equivalentNos173.0173.01.0FalseNoneNoneFalseNoneFalse173.00
3041709102778Nonecode167Supplying & Installing, testing and commissioning of Shower mixer unit with 15mm dia. bend pipe, spout and overhead shower comprising of CP shower arm, pressure adjustable shower rose with CP wall flanges , wall mixer etc., complete.Nos4800.04800.01.0FalseNoneNoneFalseNoneFalse4800.00
3041710102778Nonecode168Fixing of approved make vertical / horizontal type Electric water heater with heating elements with thermostat, 2 Nos. 15 mm dia. CP angle valve, pressure relief valve, non-return valve with CP copper connecting pipes with wall flanges etc., complete. -- a) Capacity : 25 lts. 1.5 K.W heating elementNos9500.09500.01.0FalseNoneNoneFalseNoneFalse9500.00
17103284860000NoneNoneBuildingsGovernment First Grade College in Ranebennur at Haveri District Under RUSA 27598577.29
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3041711102779Nonecode01Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates -- Vol - 1 (Common SR) P No 17 -- 2.5.2Cum8794.628794.6260.91FalseNoneNoneFalseNoneFalse535680.30420
3041712102779Nonecode02Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates --- Vol - 1 (Common SR) P No 17 -- 2.5.2Cum12459.0512459.0517.7FalseNoneNoneFalseNoneFalse220525.1850
3041713102779Nonecode03Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates -- Vol - 1 (Common SR) P No 17 -- 2.5.2Cum12459.0512459.051.66FalseNoneNoneFalseNoneFalse20682.0230
3041714102779Nonecode04Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates --- Vol - 1 (Common SR) P No 17 -- 2.5.2Cum8794.628794.6265.36FalseNoneNoneFalseNoneFalse574816.36320
3041715102779Nonecode05Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates -- Vol - 1 (Common SR) P No 17 -- 2.5.2Cum8794.628794.624.27FalseNoneNoneFalseNoneFalse37553.02740
3041716102779Nonecode06Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates --- Vol - 1 (Common SR) P No 17 -- 2.5.2Cum8794.628794.623.66FalseNoneNoneFalseNoneFalse32188.30920
3041717102779Nonecode07Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates -- Vol - 1 (Common SR) P No 17 -- 2.5.2Cum8794.628794.629.89FalseNoneNoneFalseNoneFalse86978.79180
3041718102779Nonecode08Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates --- Vol - 1 (Common SR) P No 17 -- 2.5.2Cum8880.858880.852.71FalseNoneNoneFalseNoneFalse24067.10350
3041719102779Nonecode09Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates --- Vol - 1 (Common SR) P No 17 -- 2.52Cum8880.858880.850.91FalseNoneNoneFalseNoneFalse8081.57350
3041720102779Nonecode10Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates --- Vol - 1 (Common SR) P No 17 -- 2.52Cum9391.89391.81.5FalseNoneNoneFalseNoneFalse14087.70
3041721102779Nonecode11Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) -- Vol - 1 (Building SR) P No 84 -- 11.32Tonne95808.4595808.4516.61FalseNoneNoneFalseNoneFalse1591378.35450
3041722102779Nonecode12Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) -- Vol - 1 (Building SR) P No 84 -- 11.32Tonne96747.7596747.750.79FalseNoneNoneFalseNoneFalse76430.72250
3041723102779Nonecode13Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. -- Vol - 1 (Building SR) P No 17 -- 6.32Sqm1403.011403.01867.35FalseNoneNoneFalseNoneFalse1216900.72350
3041724102779Nonecode14Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. -- Vol - 1 (Building SR) P No 17 -- 6.32Sqm1416.771416.7723.37FalseNoneNoneFalseNoneFalse33109.91490
3041725102779Nonecode15Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. -- Vol - 1 (Building SR) P No 17 -- 6.32Sqm1416.771416.7761.4427FalseNoneNoneFalseNoneFalse87050.1740790
3041726102779Nonecode16Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. -- Vol - 2 (Building SR) P No 100 -- 12.12Cum133020.34133020.340.5FalseNoneNoneFalseNoneFalse66510.170
3041727102779Nonecode17Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. -- Vol - 2 (Building SR) P No 100 -- 12.51Nos1088.141088.144.0FalseNoneNoneFalseNoneFalse4352.560
3041728102779Nonecode18Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. -- Vol - 2 (Building SR) P No 100 -- 12.51Nos1098.81098.81.0FalseNoneNoneFalseNoneFalse1098.80
3041729102779Nonecode19Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ) -- Vol - 2 (Building SR) P No 100 -- 12.15Sqm7972.527972.529.2FalseNoneNoneFalseNoneFalse73347.1840
3041730102779Nonecode20Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ) -- Vol - 2 (Building SR) P No 100 -- 12.15Sqm8050.698050.694.37FalseNoneNoneFalseNoneFalse35181.51530
3041731102779Nonecode21Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial -- Vol - 2 (Building SR) P No 100 -- 12.57.6Sqm3557.863557.8614.4FalseNoneNoneFalseNoneFalse51233.1840
3041732102779Nonecode22Providing & Fixing of Hold fast MS to wall including cost of materials, labour charges, complete as per specifications.Providing & Fixing of corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications. --A-25 -- 444Nos53.5553.5524.0FalseNoneNoneFalseNoneFalse1285.20
3041733102779Nonecode23Providing & Fixing of Hold fast MS to wall including cost of materials, labour charges, complete as per specifications.Providing & Fixing of corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications. -- A -25 -- 444Nos54.0854.082.0FalseNoneNoneFalseNoneFalse108.160
3041734102779Nonecode24Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) -- Vol - 2 (Building SR) P No 112 -- 12.90Sqm7212.117212.1166.69FalseNoneNoneFalseNoneFalse480975.61590
3041735102779Nonecode25Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. -- Vol - 2 (Building SR) P No 41 -- 8.4.1Sqm345.93345.93435.74FalseNoneNoneFalseNoneFalse150735.53820
3041736102779Nonecode26Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. -- Vol - 2 (Building SR) P No 41 -- 8.4.1Sqm349.32349.3218.2FalseNoneNoneFalseNoneFalse6357.6240
3041737102779Nonecode27Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. -- Vol - 2 (Building SR) P No 42 -- 8.8Sqm397.34397.34267.88FalseNoneNoneFalseNoneFalse106439.43920
3041738102779Nonecode28Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. -- Vol - 2 (Building SR) P No 42 -- 8.8Sqm401.24401.24204.0FalseNoneNoneFalseNoneFalse81852.960
3041739102779Nonecode29Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. -- Vol - 2 (Building SR) P No 50 -- 8.51Sqm107.1107.1435.74FalseNoneNoneFalseNoneFalse46667.7540
3041740102779Nonecode30Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. -- Vol - 2 (Building SR) P No 50 -- 8.51Sqm108.15108.15267.88FalseNoneNoneFalseNoneFalse28971.2220
3041741102779Nonecode31Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. -- Vol - 2 (Building SR) P No 50 -- 8.51Sqm108.15108.15204.0FalseNoneNoneFalseNoneFalse22062.60
3041742102779Nonecode32Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. -- Vol - 2 (Building SR) P No 42 -- 8.8Sqm397.34397.34328.76FalseNoneNoneFalseNoneFalse130629.49840
3041743102779Nonecode33Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. -- Vol - 2 (Building SR) P No 42 -- 8.8Sqm401.24401.24156.98FalseNoneNoneFalseNoneFalse62986.65520
3041744102779Nonecode34Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. -- Vol - 2 (Building SR) P No 42 -- 8.8Sqm397.34397.3440.8FalseNoneNoneFalseNoneFalse16211.4720
3041745102779Nonecode35Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. -- Vol - 2 (Building SR) P No 42 -- 8.8Sqm401.24401.2441.4FalseNoneNoneFalseNoneFalse16611.3360
3041746102779Nonecode36Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. -- Vol - 2 (Building SR) P No 73 -- 7.18Cum2160.212160.2116.43FalseNoneNoneFalseNoneFalse35492.25030
3041747102779Nonecode37Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. -- Vol - 2 (Building SR) P No 85 -- 11.34BKg195.99195.991200.42FalseNoneNoneFalseNoneFalse235270.31580
3041748102779Nonecode38Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 800x800 mm -- Vol - 2 (Building SR) P No 62 -- 9.21.2Sqm1325.91325.9407.82FalseNoneNoneFalseNoneFalse540728.5380
3041749102779Nonecode39Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. -- Vol - 2 (Building SR) P No 63 -- 9.23Sqm2641.092641.0924.2FalseNoneNoneFalseNoneFalse63914.3780
3041750102779Nonecode40Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 ems c/c both horizontally and vertically fixed with chicken mesh for drop chajja, facia, backing to cup boards including cost of all materials, labour, providing and removing form work HOM curing, complete as per specifications.Specification No. KBS -- Vol - 2 (Building SR) P No 63 -- 8.16ASqm1325.91325.918.0FalseNoneNoneFalseNoneFalse23866.20
3041751102779Nonecode41Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. -- Vol - 2 (Building SR) P No 48 -- 8.39Sqm136.02136.02267.88FalseNoneNoneFalseNoneFalse36437.03760
3041752102779Nonecode42Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. -- Vol - 2 (Building SR) P No 46 -- 8.29Sqm303.09303.0932.88FalseNoneNoneFalseNoneFalse9965.59920
3041753102779Nonecode43Providing and applying two coats of ready mix paint of approved brand on steel surface after thorough cleaning of surface to give an even shade -- Vol - 3 (Road & Bridges SR) P No 56 -- 8.11(803)Sqm102.82102.8266.69FalseNoneNoneFalseNoneFalse6857.06580
3041754102779Nonecode44Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. -- Vol - 2 (Building SR) P No -- 8.33.2Sqm147.8147.827.65FalseNoneNoneFalseNoneFalse4086.670
3041755102779Nonecode45Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. -- Vol - 2 (Building SR) P No -- 15.1Sqm875.01875.01350.0FalseNoneNoneFalseNoneFalse306253.50
3041756102779Nonecode46Internal Wiring - Point wiring using Copper wire with switch Supplying & wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5sqmm (Phase & Neutral) & 1x1.0sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. --- Short point upto 3Mtr from tapping point to outlet via switch. - Page - 5 -- 2.2.1Point269.0269.010.0FalseNoneNoneFalseNoneFalse2690.00
3041757102779Nonecode47Internal Wiring - Point wiring using Copper wire with switch Supplying & wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5sqmm (Phase & Neutral) & 1x1.0sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.--- Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switch. - Page - 5 -- 2.2.2Point379.0379.015.0FalseNoneNoneFalseNoneFalse5685.00
3041758102779Nonecode48Internal Wiring - Point wiring using Copper wire with switch Supplying & wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5sqmm (Phase & Neutral) & 1x1.0sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.--- Long point above 6Mtr upto 10Mtr from tapping point to outlet via switch. - Page - 5 -- 2.2.3Point555.0555.020.0FalseNoneNoneFalseNoneFalse11100.00
3041759102779Nonecode49Internal Wiring - Point wiring using Copper wire with switch Supplying & wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5sqmm (Phase & Neutral) & 1x1.0sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.--- Two outlet in a row, above 3Mtr upto 6Mtr from tapping point to outlet via switches. - Page - 5 -- 2.2.4Point677.0677.010.0FalseNoneNoneFalseNoneFalse6770.00
3041760102779Nonecode50Internal Wiring - Point wiring using Copper wire with switch Supplying & wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5sqmm (Phase & Neutral) & 1x1.0sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.--- Three outlet in a row, above 6Mts upto 10Mtr from tapping point to out let via switches. - Page - 5 -- 2.2.5Point989.0989.015.0FalseNoneNoneFalseNoneFalse14835.00
3041761102779Nonecode51Supplying heavy gauge PVC conduit pipe 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary.---19/20mm dia 2mm thick - Page - 2 -- 1.2.1Mtr66.066.095.0FalseNoneNoneFalseNoneFalse6270.00
3041762102779Nonecode52Supplying heavy gauge PVC conduit pipe 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. --- 25mm dia 2mm thick - Page - 2 -- 1.2.2Mtr78.078.0185.0FalseNoneNoneFalseNoneFalse14430.00
3041763102779Nonecode53Supplying heavy gauge PVC conduit pipe 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary.--- 32mm dia 2.5mm thick - Page - 2 -- 1.2.3Mtr103.0103.050.0FalseNoneNoneFalseNoneFalse5150.00
3041764102779Nonecode54Supplying heavy gauge PVC Conduit Pipe 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. -- 19/20mm dia 2mm thick - Page - 2 -- 1.3.1Mtr68.068.050.0FalseNoneNoneFalseNoneFalse3400.00
3041765102779Nonecode55Supplying heavy gauge PVC Conduit Pipe 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.----25mm dia 2mm thick - Page - 2 -- 1.3.2Mtr79.079.085.0FalseNoneNoneFalseNoneFalse6715.00
3041766102779Nonecode56Supplying heavy gauge PVC Conduit Pipe 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. -- 32mm dia 2.5mm thick - Page - 2 -- 1.3.3Mtr99.099.020.0FalseNoneNoneFalseNoneFalse1980.00
3041767102779Nonecode57Supplying and fixing PVC/metal conduit Deep junction box---19/20mm deep junction box - Page - 2 -- 1.5.1Each28.028.060.0FalseNoneNoneFalseNoneFalse1680.00
3041768102779Nonecode58Supplying and fixing PVC/metal conduit Deep junction box---25mm deep junction box - Page - 2 -- 1.5.2Each35.035.030.0FalseNoneNoneFalseNoneFalse1050.00
3041769102779Nonecode59Supplying and fixing PVC/metal conduit Deep junction box---32mm deep junction box - Page - 2 -- 1.5.3Each43.043.015.0FalseNoneNoneFalseNoneFalse645.00
3041770102779Nonecode60Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cuttingin Brick/Stone/C.C wall.---1-3Way - Page - 8 -- 3.4.1Each138.0138.05.0FalseNoneNoneFalseNoneFalse690.00
3041771102779Nonecode61Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cuttingin Brick/Stone/C.C wall.---4-5Way - Page - 8 -- 3.4.3Each177.0177.05.0FalseNoneNoneFalseNoneFalse885.00
3041772102779Nonecode62Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cuttingin Brick/Stone/C.C wall.---6Way - Page - 8 -- 3.4.4Each220.0220.05.0FalseNoneNoneFalseNoneFalse1100.00
3041773102779Nonecode63Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cuttingin Brick/Stone/C.C wall.---8Way - Page - 8 -- 3.4.5Each261.0261.010.0FalseNoneNoneFalseNoneFalse2610.00
3041774102779Nonecode64Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cuttingin Brick/Stone/C.C wall.---10-12Way - Page - 8 -- 3.4.6Each319.0319.05.0FalseNoneNoneFalseNoneFalse1595.00
3041775102779Nonecode65Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.----1 to 3 Module - Page - 8 -- 3.5.2Each161.0161.05.0FalseNoneNoneFalseNoneFalse805.00
3041776102779Nonecode66Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.---4 Module - Page - 8 -- 3.5.3Each175.0175.05.0FalseNoneNoneFalseNoneFalse875.00
3041777102779Nonecode67Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.---6 Module - Page - 8 -- 3.5.4Each234.0234.05.0FalseNoneNoneFalseNoneFalse1170.00
3041778102779Nonecode68Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.----8 Module - Page - 8 -- 3.5.5Each284.0284.010.0FalseNoneNoneFalseNoneFalse2840.00
3041779102779Nonecode69Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.----10 -12 Module - Page - 8 -- 3.5.6Each344.0344.05.0FalseNoneNoneFalseNoneFalse1720.00
3041780102779Nonecode70Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.--- 6Amps one way Switch - Page-9 -- 3.6.1Each102.0102.075.0FalseNoneNoneFalseNoneFalse7650.00
3041781102779Nonecode71Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.---6Amps Two way Switch - Page-9 -- 3.6.2Each166.0166.02.0FalseNoneNoneFalseNoneFalse332.00
3041782102779Nonecode72Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.--- 6Amps 3way socket - Page-9 -- 3.6.3Each171.0171.040.0FalseNoneNoneFalseNoneFalse6840.00
3041783102779Nonecode73Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.--- Stepped Fan Regulator - Page-9 -- 3.6.4Each357.0357.030.0FalseNoneNoneFalseNoneFalse10710.00
3041784102779Nonecode74Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.---16Amps one way switch - Page-9 -- 3.6.8Each180.0180.02.0FalseNoneNoneFalseNoneFalse360.00
3041785102779Nonecode75Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.---6/16Amps universal socket - Page-9 -- 3.6.11Each236.0236.02.0FalseNoneNoneFalseNoneFalse472.00
3041786102779Nonecode76Supplying And Fixing M.S Rafter Clamp Set made out of M.S Flat & 14mm M.S rod. - Page-4 -- 1.12Nos160.0160.030.0FalseNoneNoneFalseNoneFalse4800.00
3041787102779Nonecode77Supplying And Fixing Metal Fan Box with Round Hook. - Page-4 -- 1.13Nos117.0117.030.0FalseNoneNoneFalseNoneFalse3510.00
3041788102779Nonecode78Extra length of GI pipe of class B 19mm dia for down rod. - Page-57 -- 13.12Nos197.0197.030.0FalseNoneNoneFalseNoneFalse5910.00
3041789102779Nonecode79Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. -- 1.5 sqmm - Page-5 -- 2.3.2Mtr26.026.0100.0FalseNoneNoneFalseNoneFalse2600.00
3041790102779Nonecode80Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.---2.5 sqmm - Page-5 -- 2.3.3Mtr42.042.0300.0FalseNoneNoneFalseNoneFalse12600.00
3041791102779Nonecode81Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.---4.0 sqmm - Page-5 -- 2.3.4Mtr63.063.0200.0FalseNoneNoneFalseNoneFalse12600.00
3041792102779Nonecode82Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.---6.0 sqmm - Page-5 -- 2.3.5Mtr92.092.050.0FalseNoneNoneFalseNoneFalse4600.00
3041793102779Nonecode83Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.---10.0 sqmm - - Page-5 -- 2.3.6Mtr167.0167.0100.0FalseNoneNoneFalseNoneFalse16700.00
3041794102779Nonecode84Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. 8Way SP&N - Page-18 -- 5.19.8Each1854.01854.01.0FalseNoneNoneFalseNoneFalse1854.00
3041795102779Nonecode85Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V up to 300mA sensitivity on existing wood/panel board. - Page-13 -- 5.20.2Each2652.02652.01.0FalseNoneNoneFalseNoneFalse2652.00
3041796102779Nonecode86Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. -- 6-32Amps SP - Page-17 -- 5.18.1Each415.0415.06.0FalseNoneNoneFalseNoneFalse2490.00
3041797102779Nonecode87Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.--- 6-32Amps DP - Page-17 -- 5.18.4Each739.0739.01.0FalseNoneNoneFalseNoneFalse739.00
3041798102779Nonecode88Supplying of 4feet - PVC Batten with integrated LED tube with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 2 x 4'- 20/22 W - Page-43 -- 11.3.3Each1269.01269.040.0FalseNoneNoneFalseNoneFalse50760.00
3041799102779Nonecode89Supply of round/square recess/surface mounted rolling type LED Down light with GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition -- LED square or round down light 15-18W - Page-44 -- 11.5.3Each1324.01324.020.0FalseNoneNoneFalseNoneFalse26480.00
3041800102779Nonecode90Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. Page-30 -- 6.1Each1492.01492.02.0FalseNoneNoneFalseNoneFalse2984.00
3041801102779Nonecode91Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. -- 48" Sweep (1200mm) Regular model Page-30 -- 6.3.1Each2984.02984.030.0FalseNoneNoneFalseNoneFalse89520.00
3041802102779Nonecode92Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. Page-56 -- 13.7.1Each112.0112.060.0FalseNoneNoneFalseNoneFalse6720.00
3041803102779Nonecode93Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. Page-57 -- 13.10Each171.0171.030.0FalseNoneNoneFalseNoneFalse5130.00
3041804102779Nonecode94Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 amps. ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire. Page-57 -- 13.14Each492.0492.02.0FalseNoneNoneFalseNoneFalse984.00
3041805102779Nonecode95Providing and fixing Testing and commissioning of CP Health faucet consisting of 1 No. 15mm dia CP Angle cock with wall flage.PVC flexible tube of 1m long tube with end nuts. Hand operated spray unit (instent type)CP Crutch etc, complete as directed by the Engineer in charge.Nos1397.01397.01.0FalseNoneNoneFalseNoneFalse1397.00
3041806102779Nonecode96Provoding & fixing testing and commissioning u PVC multi inlet floor trap conforming to IS 13592 with required P C support placed to required level as per site condition complete. 110mm dia inlet 75mm dia outlet , Make: PRINCE / ASHIRWAD / SUPREME / equivalentNos173.0173.01.0FalseNoneNoneFalseNoneFalse173.00
3041807102779Nonecode97Supplying & Installing, testing and commissioning of Shower mixer unit with 15mm dia. bend pipe, spout and overhead shower comprising of CP shower arm, pressure adjustable shower rose with CP wall flanges , wall mixer etc., complete.Nos4800.04800.01.0FalseNoneNoneFalseNoneFalse4800.00
3041808102779Nonecode98Fixing of approved make vertical / horizontal type Electric water heater with heating elements with thermostat, 2 Nos. 15 mm dia. CP angle valve, pressure relief valve, non-return valve with CP copper connecting pipes with wall flanges etc., complete. - a) Capacity : 25 lts. 1.5 K.W heating elementNos9500.09500.01.0FalseNoneNoneFalseNoneFalse9500.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17103284870000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17103284870000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17103284870000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17103284890000NoneNoneELIGIBILITYThe tender document is part and parcel of the agreement.None
17103284960000NoneNoneELIGIBILITYThe contractor shall obtain insurance coverage for all the workers deployed for this work.None
17103285010000NoneNoneELIGIBILITYFurther details of the work or any clarifications can be obtained from the office of the Executive Engineer (Central office), KHB, Cauvery Bhavan, K.G. Road, Bangalore Ph: 080-22273511 ext-317,None
17103285040000NoneNoneELIGIBILITYThe intending bidders are requested to note that they should abide by the detailed instructions and conditions contained in the Tender documents and further modifications done if any.None
17103285070000NoneNoneELIGIBILITYCorrigendum/modification/corrections, if any, will be published in the e procurement Web sites only.None
17103285110000NoneNoneELIGIBILITYKHB reserves the right to withdraw or cancel this invitation to BID/Tender without assigning any reason whatsoeverNone
17103285140000NoneNoneELIGIBILITYThe bidder shall study the Tender document Carefully and quote the ratesNone
17103285190000NoneNoneELIGIBILITYAll scanned documents to be uploaded shall be in original and are to be produced to the Executive Engineer to verify the documents within 3 days from the day of opening of Technical bid for verification, if required.None
17103285230000NoneNoneELIGIBILITYDrawings uploaded are only for Tender Purpose only.None
17103285270000NoneNoneELIGIBILITYGST shall be added separately in the estimate.None
17103285300000NoneNoneELIGIBILITYGST shall be paid to the tendered amount separately.None
17103285330000NoneNoneELIGIBILITYThe bidder should maintain register of laborers deployed and wages paid for the workers and shall produce the documents whenever called for by the competent authority. Remittance towards PF shall be commensurate with the labour component of the work involved.None
17103285370000NoneNoneELIGIBILITYThe bidder shall give an undertaking that they would abide by the provisions of employees provident fund and shall remit PF of labourers to the respective PF offices or else KHB have the right to deduct the PF amount from the work bills and remit the same to respective PF offices.None
17103285410000NoneNoneELIGIBILITYThe contractor shall quote his rates inclusive of PF as per the applicable rate as issued by the PF department from time to timeNone
17103285450000NoneNoneELIGIBILITYThe successful bidder shall give an under taking that they would abide by the provisions of the Employees Provident Fund Act.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneScanned Copy of documentary proof for having executed similar nature of work not less than 50% of tender amount as defined in Government order No.FD 480 EXP-12/2014,Bangalore dated:19.07.2014Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneScanned copy of Pre-qualification letter issued by Karnataka Housing Board.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Scanned copy of Pre-qualification letter issued by Karnataka Housing Board.
NoneNoneNoneNoneAs per Tender Documents KW-4 clause 3.3 key & critical equipments available.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- As per Tender Documents KW-4 clause 3.3 key & critical equipments available.
NoneNoneNoneNoneExecuted in any one Financial year, the minimum quantities of work as mentioned in tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Executed in any one Financial year, the minimum quantities of work as mentioned in tender document
NoneNoneNoneNoneRequired valid electrical license for executing similar nature of work as per tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Required valid electrical license for executing similar nature of work as per tender document
NoneNoneNoneNoneThe Tenderer should have executed similar water supply/sanitary engineering works as per tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- The Tenderer should have executed similar water supply/sanitary engineering works as per tender document
NoneNoneNoneNoneIncome Tax returns & PANFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneITR Filed Copy (Mentioning PAN)
NoneNoneNoneNoneGST Registration CertificateFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneTo qualify for award of this contract , each tenderer in its name should have in the last five years achieved in at least two financial years a minimum financial turnover (In all classes of civil engineering construction works only)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneScanned copy of latest GST clearance certificate.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Scanned copy of latest GST clearance certificate.
NoneNoneNoneNoneScanned copy of Credit lines/ letter of credit /Bankers certificate for at least 20% of amount put to tender in the current financial year on the name of work put to tender.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneAssessed Available Bid Capacity as per tender documentFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Assessed Available Bid Capacity as per tender document
NoneNoneNoneNoneCovering letter.OthersCovering letter.
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Covering letter.
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Company Registration CertificateFalseTechnical Bid
Reserved Category CertificateFalseTechnical Bid
Small Scale Industries CertificateFalseTechnical Bid
Work done certificateTrueTechnical Bid
key and critical equipment LISTTrueTechnical Bid
Income Tax returns & PAN no.TrueTechnical Bid
Pre-qualification certificate issued by KHBTrueTechnical Bid
GST clearance certificateTrueTechnical Bid
Credit lines/ letter of credit/Bankers certificateTrueTechnical Bid
Assessed available tender capacity calculationTrueTechnical Bid
Electrical licenseTrueTechnical Bid
Work done certificate with quantitiesTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1710336279000
version0
createdDateNone
modifiedDateNone
blockNumberCAUVERY BHAVAN 3RD FLOOR
streetNone
cityBengaluru
stateKarnataka
pin560009
tenderRecallDTONone