createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1710331871426
version5
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee7500.00
emd2033000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose12-04-2024 16:00:00
tenderQueryClose26-03-2024 14:00:10
technicalBidOpen15-04-2024 16:30:00
publishedDate13-03-2024 18:24:55
publishedByPostEWHFWD_CE_CEOFF_BNG
publishedByUserKPE16838 - BALEKATTE KUMARASWAMY PAVITHRA
bidValidityPeriod90
noOfCalls1
preBidMeetingDate27-03-2024 11:30:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonAssistant Engineer
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08029557023
mobileNumber9449843375
tenderSupplierListNone
tenderSchedule
createdTs1710331871480
version10
createdDateNone
modifiedDateNone
tenderNumberEWHFWD/2023-24/BD/WORK_INDENT385
titleCONSTRUCTION OF 50 BED CRITICAL CARE UNIT HOSPITAL IN THE PREMISES OF RIMS AT RAICHUR IN RAICHUR DISTRICT
descriptionCONSTRUCTION OF 50 BED CRITICAL CARE UNIT HOSPITAL IN THE PREMISES OF RIMS AT RAICHUR IN RAICHUR DISTRICT. GROUND FLOOR
categoryWORKS
categoryTextWorks
ecv203286654.13
deptNameEngineering Wing of Health and Family Welfare Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location3521
locationNameEWHFWD Chief Engineer Office Bengaluru
provisionalAmount218500000.0
groupOverheadTotal0.0
fileNumberAEE-07CCB
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17103318710000NoneNoneBuildingsGROUND FLOOR59001595.59
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3046202102974None2.5AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle ---- etc., complete with all leadSqm486.93486.9330.11FalseNoneNoneFalseNoneFalse14661.46230
3046203102974None1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- etc., complete with all leadCum117.71117.71903.34FalseNoneNoneFalseNoneFalse106332.15140
3046204102974None1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- etc., complete with all leadCum126.38126.381400.4FalseNoneNoneFalseNoneFalse176982.5520
3046205102974None1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth ---- etc., complete with all leadCum449.76449.76257.88FalseNoneNoneFalseNoneFalse115984.10880
3046206102974None1.15.2Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Depth exceeding 1.5 m, but not exceeding 3 m ---- etc., complete with all leadCum526.58526.5885.96FalseNoneNoneFalseNoneFalse45264.81680
3046207102974None1.1aLoading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) ---- etc., complete with all leadCum167.27167.271225.35FalseNoneNoneFalseNoneFalse204964.29450
3046208102974None4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- etc., complete with all leadCum146.2146.21882.0FalseNoneNoneFalseNoneFalse275148.40
3046209102974None1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., complete with all leadCum587.29587.295641.45FalseNoneNoneFalseNoneFalse3313167.17050
3046210102974None2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum7420.377420.37322.24FalseNoneNoneFalseNoneFalse2391140.02880
3046211102974None2.2.2.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum8478.338478.33362.89FalseNoneNoneFalseNoneFalse3076701.17370
3046212102974None2.2.2.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PEDESTAL ---- etc., complete with all leadCum8635.338635.3323.04FalseNoneNoneFalseNoneFalse198958.00320
3046213102974None2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. COLUMNS ---- etc., complete with all leadCum14413.4114413.41102.1FalseNoneNoneFalseNoneFalse1471609.1610
3046214102974None2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates LIFT CORE WALL ---- etc., complete with all leadCum14413.4114413.416.73FalseNoneNoneFalseNoneFalse97002.24930
3046215102974None2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates CURTAIN WALL ---- etc., complete with all leadCum14413.4114413.4161.72FalseNoneNoneFalseNoneFalse889595.66520
3046216102974None2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PLINTH BEAM ---- etc., complete with all leadCum12717.7212717.72114.64FalseNoneNoneFalseNoneFalse1457959.42080
3046217102974None2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RCC BEAMS ---- etc., complete with all leadCum13565.5613565.56163.62FalseNoneNoneFalseNoneFalse2219596.92720
3046218102974None2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RCC SLAB ---- etc., complete with all leadCum12717.7212717.72305.01FalseNoneNoneFalseNoneFalse3879031.77720
3046219102974None2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RCC STARICASE ---- etc., complete with all leadCum12717.7212717.727.12FalseNoneNoneFalseNoneFalse90550.16640
3046220102974None2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates LINTELS ---- etc., complete with all leadCum13565.5613565.566.43FalseNoneNoneFalseNoneFalse87226.55080
3046221102974None2.1.4Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum11911.1311911.135.04FalseNoneNoneFalseNoneFalse60032.09520
3046222102974None8.83Providing Lath plaster with cement mortar 1:3 5cm thick with 6mm dia mild steel bars at 20cms. C to c both horizontally and vertically fixing chicken mesh for drop chejjas, facia, backing to cup board including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specification. ---- etc., complete with all leadSqm1533.881533.8812.29FalseNoneNoneFalseNoneFalse18851.38520
3046223102974None11.32Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. ---- etc., complete with all leadTonne110837.22110837.22147.33FalseNoneNoneFalseNoneFalse16329647.62260
3046224102974NoneA.RExtra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No . KBS ---- etc., complete with all leadRmtr38.9438.94119.6FalseNoneNoneFalseNoneFalse4657.2240
3046225102974NoneA.RProviding throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete with all leadRmtr86.1486.14119.6FalseNoneNoneFalseNoneFalse10302.3440
3046226102974None5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete with all leadCum7915.977915.9712.12FalseNoneNoneFalseNoneFalse95941.55640
3046227102974None6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all leadSqm1623.091623.092474.57FalseNoneNoneFalseNoneFalse4016449.82130
3046228102974None6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all leadSqm1367.861367.8695.31FalseNoneNoneFalseNoneFalse130370.73660
3046229102974None12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all leadCum122431.79122431.793.08FalseNoneNoneFalseNoneFalse377089.91320
3046230102974None12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all leadNo1258.821258.8237.0FalseNoneNoneFalseNoneFalse46576.340
3046231102974None22.15.2Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm ---- etc., complete with all leadNo681.45681.4574.0FalseNoneNoneFalseNoneFalse50427.30
3046232102974None10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., complete with all leadNo74.3474.34222.0FalseNoneNoneFalseNoneFalse16503.480
3046233102974NoneA.RProviding & Fixing of corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all leadRmtr15.015.0234.6FalseNoneNoneFalseNoneFalse3519.00
3046234102974None12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial ---- etc., complete with all leadSqm4115.964115.96136.8FalseNoneNoneFalseNoneFalse563063.3280
3046235102974None12.90Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made ---- etc., complete with all leadSqm8343.438343.4378.3FalseNoneNoneFalseNoneFalse653290.5690
3046236102974None12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE (Thermo Plastic Elastomer) and lead free with gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all leadSqm7085.847085.843.24FalseNoneNoneFalseNoneFalse22958.12160
3046237102974None11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete with all leadKg208.15208.151712.34FalseNoneNoneFalseNoneFalse356423.5710
3046238102974None12.93Providing & fixing Factory made single extruded Wood Polymer composite (WPC) Solid Door /Window, clerestory windows and frames /chowkat of frame size 65 * 100mm.The cost includes cost of materials and transportation, labour and fixing charges. ---- etc., complete with all leadm869.78869.7854.0FalseNoneNoneFalseNoneFalse46968.120
3046239102974None12.96Providing and fixing factory made 100% carpenter friendly ready to use single solid plain WPC (WoodPolymer Composite) flush shutter of 30mm thickness which is anti termite & having high water absorption property. The cost includes cost of materials and transportation, labour and fixing charges. ---- etc., complete with all leadm4317.924317.9217.01FalseNoneNoneFalseNoneFalse73447.81920
3046240102974None12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ---- etc., complete with all leadNo1380.251380.2546.0FalseNoneNoneFalseNoneFalse63491.50
3046241102974None11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all leadKg168.5168.5864.0FalseNoneNoneFalseNoneFalse145584.00
3046242102974None8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) ---- etc., complete with all leadSqm386.57386.573476.18FalseNoneNoneFalseNoneFalse1343786.90260
3046243102974None8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm261.43261.432854.12FalseNoneNoneFalseNoneFalse746152.59160
3046244102974None8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all leadSqm123.9123.96330.3FalseNoneNoneFalseNoneFalse784324.170
3046245102974None8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) ---- etc., complete with all leadSqm432.41432.41943.26FalseNoneNoneFalseNoneFalse407875.05660
3046246102974None8.3.1Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm438.61438.6140.85FalseNoneNoneFalseNoneFalse17917.21850
3046247102974NoneA.RProviding and fixing plaster mesh 200mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per Sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment ) ---- etc., complete with all leadRmtr47.0847.081835.0FalseNoneNoneFalseNoneFalse86391.80
3046248102974NoneA.RBore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc., complete with all leadSqm283.2283.250.0FalseNoneNoneFalseNoneFalse14160.00
3046249102974None8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete with all leadRmtr64.4364.431073.6FalseNoneNoneFalseNoneFalse69172.0480
3046250102974None9.17.2Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.).Size of Tile 600x600 mm ---- etc., complete with all leadSqm1455.831455.831548.18FalseNoneNoneFalseNoneFalse2253886.88940
3046251102974None9.1Providing and laying Cement concrete flooring 40 mm thick with 20 mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete. ---- etc., complete with all leadSqm558.79558.79152.57FalseNoneNoneFalseNoneFalse85254.59030
3046252102974None9.21.2Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm ---- etc., complete with all leadSqm1642.911642.91431.76FalseNoneNoneFalseNoneFalse709342.82160
3046253102974None9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete with all leadSqm6601.396601.39172.07FalseNoneNoneFalseNoneFalse1135901.17730
3046254102974None8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm365.51365.51658.98FalseNoneNoneFalseNoneFalse240863.77980
3046255102974None15.7Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ---- etc., complete with all leadSqm761.99761.99101.85FalseNoneNoneFalseNoneFalse77608.68150
3046256102974None9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. ---- etc., complete with all leadSqm1101.471101.4766.96FalseNoneNoneFalseNoneFalse73754.43120
3046257102974None9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all leadSqm1795.311795.31227.22FalseNoneNoneFalseNoneFalse407930.33820
3046258102974None11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all leadKg700.04700.04749.7FalseNoneNoneFalseNoneFalse524819.9880
3046259102974None8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm157.35157.356330.3FalseNoneNoneFalseNoneFalse996072.7050
3046260102974None8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm193.28193.28943.26FalseNoneNoneFalseNoneFalse182313.29280
3046261102974None8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm61.9561.9587.3FalseNoneNoneFalseNoneFalse5408.2350
3046262102974None8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm142.49142.4987.3FalseNoneNoneFalseNoneFalse12439.3770
3046263102974None8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm65.6765.67328.32FalseNoneNoneFalseNoneFalse21560.77440
3046264102974None8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) ---- etc., complete with all leadSqm838.8838.8328.32FalseNoneNoneFalseNoneFalse275394.8160
3046265102974None18.1Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved drawings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment. ---- etc., complete with all leadKg504.27504.27546.0FalseNoneNoneFalseNoneFalse275331.420
3046266102974None7.31Providing and fixing in position 12mm thick plaster of paris (Gypsum anhydrous) for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications. ---- etc., complete with all leadSqm1578.41578.4235.88FalseNoneNoneFalseNoneFalse372312.9920
3046267102974None18.3Providing, assembling and supplying vision glass panels IGUs comprising of hermetically-sealed 6 12 6 mm insulated glass double glazed vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor.(Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2) ---- etc., complete with all leadSqm3770.283770.2884.0FalseNoneNoneFalseNoneFalse316703.520
3046268102974None7.41Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per m2 including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. ---- etc., complete with all leadSqm2097.632097.63353.82FalseNoneNoneFalseNoneFalse742183.44660
3046269102974None10.1.1Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2 ---- etc., complete with all leadSqm4963.434963.4360.0FalseNoneNoneFalseNoneFalse297805.80
3046270102974None6.5Providing Brick work with common burnt clay machine moulded perforated bricks of class designation 5.0 conforming to IS: 2222 in superstructure above plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) With Non modular bricks including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. ---- etc., complete with all leadCum13600.513600.538.19FalseNoneNoneFalseNoneFalse519403.0950
3046271102974None9.137Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-in-charge (panneling to be paid for separately). ---- etc., complete with all leadSqm6790.226790.2216.92FalseNoneNoneFalseNoneFalse114890.52240
3046272102974NoneA.RProviding and fixing aluminium coated and polyester based netted curtains complete. The work includes cost of all materials, labour charges, lead and lift, etc., complete. ---- etc., complete with all leadRmtr2596.02596.080.0FalseNoneNoneFalseNoneFalse207680.00
3046273102974None9.136Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge (Dash fastener to bepaid for separately). ---- etc., complete with all leadRmtr1541.111541.1148.0FalseNoneNoneFalseNoneFalse73973.280
3046274102974None9.32Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ---- etc., complete with all leadSqm3199.13199.159.79FalseNoneNoneFalseNoneFalse191274.1890
3046275102974None22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm ---- etc., complete with all leadNo464.63464.6337.0FalseNoneNoneFalseNoneFalse17191.310
3046276102974None22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm ---- etc., complete with all leadNo185.85185.8574.0FalseNoneNoneFalseNoneFalse13752.90
3046277102974None22.15.9Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm ---- etc., complete with all leadNos86.7386.73148.0FalseNoneNoneFalseNoneFalse12836.040
3046278102974None22.15.10Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm ---- etc., complete with all leadNo123.9123.937.0FalseNoneNoneFalseNoneFalse4584.30
3046279102974None12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete with all leadNo1303.431303.4337.0FalseNoneNoneFalseNoneFalse48226.910
3046280102974None18.4Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge. ---- etc., complete with all leadSqm5151.765151.7624.0FalseNoneNoneFalseNoneFalse123642.240
3046281102974NoneA.RThe Tenderer (agency) should arrange to obtain (get), detailed Architectural drawings and elevations, Structural designs and drawings including Soil exploration &proof checking by reputedGovernment/Semi Government/IISC /IIT/NIT/or as decided by the Department and the same has to be furnished to the Department for approval and providing consultancy for Architectural designs & drawings, elevation, 3D view, MFP design and Drawings, Internal and External Electrical services including electrical infrastructure, MGPLS, Fire Fighting, Modular OT,HVAC, etc.interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project and 6 sets of as built drawings should be submitted to the employer. ---- etc., complete with all leadJob2000000.02000000.01.0FalseNoneNoneFalseNoneFalse2000000.00
17103318720000NoneNoneBuildingsFIRST FLOOR34290230.47
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3046282102975None2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates COLUMNS ---- etc., complete with all leadCum14557.5514557.5570.63FalseNoneNoneFalseNoneFalse1028199.75650
3046283102975None2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RCC BEMAS ---- etc., complete with all leadCum13701.2213701.22149.23FalseNoneNoneFalseNoneFalse2044633.06060
3046284102975None2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RCC SLAB ---- etc., complete with all leadCum12844.8912844.89250.5FalseNoneNoneFalseNoneFalse3217644.9450
3046285102975None2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates STAIRCASE ---- etc., complete with all leadCum12844.8912844.896.91FalseNoneNoneFalseNoneFalse88758.18990
3046286102975None2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates LINTEL ---- etc., complete with all leadCum13701.2213701.226.2FalseNoneNoneFalseNoneFalse84947.5640
3046287102975None2.1.4Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum12030.2412030.2440.83FalseNoneNoneFalseNoneFalse491194.69920
3046288102975None2.11.ASupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. ---- etc., complete with all leadTonne111945.6111945.681.06FalseNoneNoneFalseNoneFalse9074310.3360
3046289102975None4.21Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No . KBS ---- etc., complete with all leadRmtr38.9438.94117.9FalseNoneNoneFalseNoneFalse4591.0260
3046290102975NoneA.RProviding throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete with all leadRmtr86.1486.14117.9FalseNoneNoneFalseNoneFalse10155.9060
3046291102975None6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all leadSqm1639.321639.322331.41FalseNoneNoneFalseNoneFalse3821927.04120
3046292102975None6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all leadSqm1381.531381.53209.0FalseNoneNoneFalseNoneFalse288739.770
3046293102975None12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all leadCum123656.1123656.12.6FalseNoneNoneFalseNoneFalse321505.860
3046294102975None12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all leadNo1271.411271.4135.0FalseNoneNoneFalseNoneFalse44499.350
3046295102975None22.15.2Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm ---- etc., complete with all leadNo.688.26688.2635.0FalseNoneNoneFalseNoneFalse24089.10
3046296102975None10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., complete with all leadNo75.0875.08210.0FalseNoneNoneFalseNoneFalse15766.80
3046297102975NoneA.RProviding & Fixing of corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all leadRmtr15.015.0218.9FalseNoneNoneFalseNoneFalse3283.50
3046298102975None12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial ---- etc., complete with all leadSqm4157.124157.12122.16FalseNoneNoneFalseNoneFalse507833.77920
3046299102975None12.90Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all leadSqm8426.868426.8668.76FalseNoneNoneFalseNoneFalse579430.89360
3046300102975None12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all leadSqm7156.77156.78.46FalseNoneNoneFalseNoneFalse60545.6820
3046301102975None11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete with all leadKg210.23210.231621.62FalseNoneNoneFalseNoneFalse340913.17260
3046302102975None12.93Providing & fixing Factory made single extruded Wood Polymer composite (WPC) Solid Door /Window, clerestory windows and frames /chowkat of frame size 65 * 100mm.The cost includes cost of materials and transportation, labour and fixing charges. ---- etc., complete with all leadm878.48878.48108.0FalseNoneNoneFalseNoneFalse94875.840
3046303102975None12.96Providing and fixing factory made 100% carpenter friendly ready to use single solid plain WPC (WoodPolymer Composite) flush shutter of 30mm thickness which is anti termite & having high water absorption property. The cost includes cost of materials and transportation, labour and fixing charges. ---- etc., complete with all leadSqm4361.094361.0934.02FalseNoneNoneFalseNoneFalse148364.28180
3046304102975None12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ---- etc., complete with all leadNo1394.051394.0551.0FalseNoneNoneFalseNoneFalse71096.550
3046305102975None8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) ---- etc., complete with all leadSqm390.43390.433351.13FalseNoneNoneFalseNoneFalse1308381.68590
3046306102975None8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm264.04264.042447.08FalseNoneNoneFalseNoneFalse646127.00320
3046307102975None8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all leadSqm125.14125.145798.2FalseNoneNoneFalseNoneFalse725586.7480
3046308102975None8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) ---- etc., complete with all leadSqm436.74436.74850.86FalseNoneNoneFalseNoneFalse371604.59640
3046309102975None8.3.1Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm442.99442.9929.64FalseNoneNoneFalseNoneFalse13130.22360
3046310102975None8.16.2Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide ---- etc., complete with all leadRmtr47.5547.551773.0FalseNoneNoneFalseNoneFalse84306.150
3046311102975None7.18Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. ---- etc., complete with all leadCum2524.052524.0522.63FalseNoneNoneFalseNoneFalse57119.25150
3046312102975None15.7Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ---- etc., complete with all leadCum769.6769.6116.37FalseNoneNoneFalseNoneFalse89558.3520
3046313102975NoneA.RBore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc., complete with all leadSqm283.2283.250.0FalseNoneNoneFalseNoneFalse14160.00
3046314102975None8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete with all leadRmtr65.0765.07962.0FalseNoneNoneFalseNoneFalse62597.340
3046315102975None9.17.2Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.).Size of Tile 600x600 mm ---- etc., complete with all leadSqm1470.381470.381415.24FalseNoneNoneFalseNoneFalse2080940.59120
3046316102975None9.21.2Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm ---- etc., complete with all leadSqm1659.341659.34360.72FalseNoneNoneFalseNoneFalse598557.12480
3046317102975None9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete with all leadSqm6667.416667.41142.0FalseNoneNoneFalseNoneFalse946772.220
3046318102975None8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm369.16369.16603.27FalseNoneNoneFalseNoneFalse222703.15320
3046319102975None9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. ---- etc., complete with all leadSqm1112.491112.4975.42FalseNoneNoneFalseNoneFalse83903.99580
3046320102975None9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all leadSqm1813.261813.26242.55FalseNoneNoneFalseNoneFalse439806.2130
3046321102975None11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all leadKg707.04707.04749.7FalseNoneNoneFalseNoneFalse530067.8880
3046322102975None8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm158.93158.935798.2FalseNoneNoneFalseNoneFalse921507.9260
3046323102975None8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm195.22195.22850.86FalseNoneNoneFalseNoneFalse166104.88920
3046324102975None8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm62.5762.5781.54FalseNoneNoneFalseNoneFalse5101.95780
3046325102975None8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm143.91143.9181.54FalseNoneNoneFalseNoneFalse11734.42140
3046326102975None8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm66.3266.32293.18FalseNoneNoneFalseNoneFalse19443.69760
3046327102975None8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) ---- etc., complete with all leadSqm847.19847.19293.18FalseNoneNoneFalseNoneFalse248379.16420
3046328102975None18.1Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved drawings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment. ---- etc., complete with all leadKg509.32509.32546.0FalseNoneNoneFalseNoneFalse278088.720
3046329102975None18.3Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically sealed 6 12 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2)For payment, only the actual area of glass on face NO 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/ m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. ---- etc., complete with all leadSqm3807.983807.9884.0FalseNoneNoneFalseNoneFalse319870.320
3046330102975None18.4Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge. ---- etc., complete with all leadSqm5203.285203.2884.0FalseNoneNoneFalseNoneFalse437075.520
3046331102975None7.31Providing and fixing in position 12mm thick plaster of paris (Gypsum anhydrous) for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications. ---- etc., complete with all leadSqm1594.271594.27137.9FalseNoneNoneFalseNoneFalse219849.8330
3046332102975None7.41Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per m2 including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. ---- etc., complete with all leadSqm2118.62118.6206.8FalseNoneNoneFalseNoneFalse438126.480
3046333102975None10.1.1Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2 ---- etc., complete with all leadSqm5013.075013.0760.0FalseNoneNoneFalseNoneFalse300784.20
3046334102975NoneA.RProviding and fixing aluminium coated and polyester based netted curtains complete. The work includes cost of all materials, labour charges, lead and lift, etc., complete. ---- etc., complete with all leadRmtr2596.02596.080.0FalseNoneNoneFalseNoneFalse207680.00
3046335102975None22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm ---- etc., complete with all leadNo469.27469.2735.0FalseNoneNoneFalseNoneFalse16424.450
3046336102975None22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm ---- etc., complete with all leadNo187.71187.7170.0FalseNoneNoneFalseNoneFalse13139.70
3046337102975None22.15.9Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm ---- etc., complete with all leadNo87.687.6140.0FalseNoneNoneFalseNoneFalse12264.00
3046338102975None22.15.10Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm ---- etc., complete with all leadNo125.14125.1435.0FalseNoneNoneFalseNoneFalse4379.90
3046339102975None12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete with all leadNo1316.461316.4621.0FalseNoneNoneFalseNoneFalse27645.660
17103318720000NoneNoneBuildingsTERRACE FLOOR6450302.72
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3046340102976NoneItem 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork ---- etc., complete with all leadCum14701.6814701.6822.86FalseNoneNoneFalseNoneFalse336080.40480
3046341102976NoneItem 2.5.2RCC BEAMS Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum13836.8713836.8716.54FalseNoneNoneFalseNoneFalse228861.82980
3046342102976NoneItem 2.5.2RCC SLAB Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum12972.0712972.0721.02FalseNoneNoneFalseNoneFalse272672.91140
3046343102976NoneItem 2.5.2LINTELS Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum13836.8713836.870.3FalseNoneNoneFalseNoneFalse4151.0610
3046344102976NoneItem 2.5.1Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregatesTERRACE FLOOR ---- etc., complete with all leadCum12149.3512149.350.46FalseNoneNoneFalseNoneFalse5588.7010
3046345102976NoneItem 2.11 aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. ---- etc., complete with all leadMT113053.97113053.978.11FalseNoneNoneFalseNoneFalse916867.69670
3046346102976NoneItem 4.21Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. ---- etc., complete with all leadm38.9438.9413.0FalseNoneNoneFalseNoneFalse506.220
3046347102976NoneItem Approved RateProviding throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete with all leadm86.1486.14182.0FalseNoneNoneFalseNoneFalse15677.480
3046348102976NoneItem 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all leadSqm1655.551655.55439.92FalseNoneNoneFalseNoneFalse728309.5560
3046349102976NoneItem 12.90Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all leadSqm8510.298510.294.32FalseNoneNoneFalseNoneFalse36764.45280
3046350102976NoneItem 11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete with all leadKg212.32212.32113.4FalseNoneNoneFalseNoneFalse24077.0880
3046351102976NoneItem 11.5.1Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. ---- etc., complete with all leadSqm5659.215659.215.76FalseNoneNoneFalseNoneFalse32597.04960
3046352102976NoneItem 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) ---- etc., complete with all leadSqm394.3394.3229.92FalseNoneNoneFalseNoneFalse90657.4560
3046353102976NoneItem 8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm266.66266.66103.78FalseNoneNoneFalseNoneFalse27673.97480
3046354102976NoneItem 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all leadSqm125.14125.14333.7FalseNoneNoneFalseNoneFalse41759.2180
3046355102976NoneItem 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) ---- etc., complete with all leadSqm441.06441.06801.52FalseNoneNoneFalseNoneFalse353518.41120
3046356102976NoneItem Approved RateRoof Water Proofing. Surface Preparation: remove all surface laitance and contamination free from loose aggregate or other sharp protrusions with fairly smooth finish by wire brush and grinding method and surface shall be DRY for application of single component pitch modified polyurethane cures by reaction with atmospheric moisture to given a tough elastomeric waterproof membrane. System : Provide and applying 1.2 mm thick roller applied single component bitumen modified polyurathene coating NITPROOF 600 or equivalent, having elongation capacity of 450 % as per ASTM D412, having Tensile strength 1.5 n/mm2 as per ASTM D 412, Tear resistance of 15 N as per ASTM D 624 and having shore A Hardness 50 as per ASTM D 2240. Waterproofing treatment to be provided after proper surface preparation as per Manufacture Specification. Protection of waterproofing system with minimum 50 mm thick screed and providing construction joints and sealing the same with PU sealant.TERRACE FLOOR ---- etc., complete with all leadSqm1593.01593.01850.0FalseNoneNoneFalseNoneFalse2947050.00
3046357102976NoneItem 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm160.5160.5333.7FalseNoneNoneFalseNoneFalse53558.850
3046358102976NoneItem 8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm197.15197.15801.52FalseNoneNoneFalseNoneFalse158019.6680
3046359102976NoneItem 8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm63.1963.1911.16FalseNoneNoneFalseNoneFalse705.20040
3046360102976NoneItem 8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm145.33145.3311.16FalseNoneNoneFalseNoneFalse1621.88280
3046361102976NoneItem 10.1.7Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 ---- etc., complete with all leadm519.41519.41180.0FalseNoneNoneFalseNoneFalse93493.80
3046362102976NoneItem 7.1.2supports of same angle iron etc. as directed, including hand railing on both sides with 25mm dia. GI pipes with angle iron props at 2 mtrs. intervals and 0.5M heigh, including fixing in ground with CC 1:2:4 and two coats of anticorrosive bituminous paint etc. with all lead and lifts etc. complete with:: MS angle of 65 x 65 x 10mm ---- etc., complete with all leadm6067.416067.4113.2FalseNoneNoneFalseNoneFalse80089.8120
17103318720000NoneNoneBuildingsINTERNAL WATER SUPPLY AND SANITARY WORKS2949568.38
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3046363102977NoneItem 13.50.5Providing and fixing Unplasticised Polyvinyl Chloride uPVC pipes, for cold water supply including all uPVC plain and brass threaded fittingsThis includes jointing of pipes and fittings with one step uPVC solventcement, trenching, refilling and testing of joints complete as per directionof Engineer in Charge. 40mm dia pipes, From wash basin waste lines ---- etc., complete with all leadm376.66376.6640.0FalseNoneNoneFalseNoneFalse15066.40
3046364102977NoneItem 13.50.6Providing and fixing Unplasticised Polyvinyl Chloride uPVC pipes, forcold water supply including all uPVC plain and brass threaded fittingsThis includes jointing of pipes and fittings with one step uPVC solventcement, trenching, refilling and testing of joints complete as per directionof Engineer in Charge. 50mm dia pipes, From sink and urinal waste lines ---- etc., complete with all leadm478.25478.2510.0FalseNoneNoneFalseNoneFalse4782.50
3046365102977NoneItem 13.64.1Providing and fixing Sewer SWR pipes, including all fittings, This includes jointing of pipes and fittings with one step solvent cement,trenching, refilling and testing of joints complete as per direction ofEngineer in Charge. Internal drainage 75mm nominal dia pipes ---- etc., complete with all leadm358.07358.0765.0FalseNoneNoneFalseNoneFalse23274.550
3046366102977NoneItem 13.64.2Providing and fixing Sewer SWR pipes, including all fittings, Thisincludes jointing of pipes and fittings with one step solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. Internal drainage 110mm nominal dia pipes ---- etc., complete with all leadm477.02477.0253.0FalseNoneNoneFalseNoneFalse25282.060
3046367102977NoneItem 13.63Providing and fixing PVC S.W.R Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements and all necessary accessoriescomplete ---- etc., complete with all leadEach302.32302.3239.0FalseNoneNoneFalseNoneFalse11790.480
3046368102977NoneItem 13.37Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc.with cement concrete 1:2:4 1 cement : 2 coarse sand : 4 graded stoneaggregate 20 mm nominal size, including finishing complete so as tomake it leak proof. ---- etc., complete with all leadEach387.81387.8118.0FalseNoneNoneFalseNoneFalse6980.580
3046369102977NoneItem 14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass of approved quality complete with 6 mm thick hrd board ground fixedto wooden cleats with C.P. brass screws and washers complete. ---- etc., complete with all leadEach1511.581511.5815.0FalseNoneNoneFalseNoneFalse22673.70
3046370102977NoneItem 13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter ---- etc., complete with all leadNos345.68345.6810.0FalseNoneNoneFalseNoneFalse3456.80
3046371102977NoneItem 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality and make as approved by Engineer in charge. ---- etc., complete with all leadEach6891.326891.3210.0FalseNoneNoneFalseNoneFalse68913.20
3046372102977NoneItem 14.40.2Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g ---- etc., complete with all leadEach614.54614.5410.0FalseNoneNoneFalseNoneFalse6145.40
3046373102977NoneItem 14.38Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 g ---- etc., complete with all leadEach179.66179.6610.0FalseNoneNoneFalseNoneFalse1796.60
3046374102977NoneItem 13.16Providing and fixing C.P. brass angle valve for basin mixer and geyserpoints of approved quality conforming to IS:8931 ---- etc., complete with all leadEach768.18768.1848.0FalseNoneNoneFalseNoneFalse36872.640
3046375102977NoneItem 14.2.1Providing and fixing white vitreous china pedestal type water closetEuropean type W.C. pan with seat and lid, 10 litre low level white P.V.C.flushing cistern, including flush pipe, with manually controlled devicehandle lever, conforming to IS : 7231, with all fittings and fixturescomplete, including cutting and making good the walls and floors whereverrequired : W.C. pan with ISI marked white solid plastic seat and lid ---- etc., complete with all leadEach13496.4313496.4316.0FalseNoneNoneFalseNoneFalse215942.880
3046376102977NoneItem 14.4.1Providing and fixing white vitreous china flat back or wall corner typelipped front urinal basin of 430x260x350 mm and 340x410x265 mmsizes respectively with automatic flushing cistern with standard flushpipe and C.P. brass spreaders with brass unions and G.I clamps complete,including painting of fittings and brackets, cutting and making good thewalls and floors wherever required: One urinal basin with 5 litre white P.V.C. automatic flushing cistern ---- etc., complete with all leadEach5518.515518.512.0FalseNoneNoneFalseNoneFalse11037.020
3046377102977NoneItem 13.15Providing and fixing C.P. brass stop cock concealed of standard design and of approved make conforming to IS:8931. ---- etc., complete with all leadNos898.28898.2835.0FalseNoneNoneFalseNoneFalse31439.80
3046378102977NoneItem 14.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps ---- etc., complete with all leadEach3818.63818.613.0FalseNoneNoneFalseNoneFalse49641.80
3046379102977NoneItem 14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved qualityand make and as per the direction of Engineer-in-charge. ---- etc., complete with all leadEach1003.591003.5928.0FalseNoneNoneFalseNoneFalse28100.520
3046380102977NoneItem 13.8.1.1Providing and fixing unplasticised PVC connection pipe with brass unions :30 cm length 15 mm nominal bore ---- etc., complete with all leadEach102.84102.8428.0FalseNoneNoneFalseNoneFalse2879.520
3046381102977NoneItem 14.37.1Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effectivelength of tail pipe 260 mm from the centre of the waste coupling, 77 mmbreadth with 25 mm minimum water seal, weighing not less than 260 g ---- etc., complete with all leadEach379.13379.1328.0FalseNoneNoneFalseNoneFalse10615.640
3046382102977NoneItem 14.36.1Providing and fixing PTMT Waste Coupling for wash basin and sink, ofapproved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 g ---- etc., complete with all leadEach111.51111.5130.0FalseNoneNoneFalseNoneFalse3345.30
3046383102977NoneItem 13.2.1Providing and fixing brass bib cock of approved quality 15 mm nominal bore ---- etc., complete with all leadNos354.35354.3546.0FalseNoneNoneFalseNoneFalse16300.10
3046384102977NoneItem 9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete with all leadSqm5335.135335.1318.0FalseNoneNoneFalseNoneFalse96032.340
3046385102977NoneItem 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, iorc fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.15 mm nominal dia Pipes ---- etc., complete with all leadm374.18374.1830.0FalseNoneNoneFalseNoneFalse11225.40
3046386102977NoneItem 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, iorc fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia Pipes ---- etc., complete with all leadm469.58469.5838.0FalseNoneNoneFalseNoneFalse17844.040
3046387102977NoneItem 13.32.3Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, iorc fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.25 mm nominal dia pipes ---- etc., complete with all leadm591.0591.0186.0FalseNoneNoneFalseNoneFalse109926.00
3046388102977NoneItem 13.32.4Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, iorc fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.32 mm nominal dia pipes ---- etc., complete with all leadm690.12690.1245.0FalseNoneNoneFalseNoneFalse31055.40
3046389102977NoneItem 13.31.5Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work Exposed on wall 40 mm nominal dia Pipes ---- etc., complete with all leadm664.1664.130.0FalseNoneNoneFalseNoneFalse19923.00
3046390102977NoneItem 13.31.6Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work Exposed on wall 50 mm nominal dia Pipes ---- etc., complete with all leadm967.66967.6620.0FalseNoneNoneFalseNoneFalse19353.20
3046391102977NoneItem 13.33.4Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External work 32 mm nominal dia Pipes ---- etc., complete with all leadm460.91460.91360.0FalseNoneNoneFalseNoneFalse165927.60
3046392102977NoneItem 13.33.5Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External work 40 mm nominal dia Pipe ---- etc., complete with all leadm591.0591.0210.0FalseNoneNoneFalseNoneFalse124110.00
3046393102977NoneItem 13.33.6Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External work50 mm nominal dia Pipes ---- etc., complete with all leadm893.32893.32215.0FalseNoneNoneFalseNoneFalse192063.80
3046394102977NoneItem 13.5.2Providing and fixing ball valve brass of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore ---- etc., complete with all leadNos843.76843.7630.0FalseNoneNoneFalseNoneFalse25312.80
3046395102977NoneItem 13.4.2Providing and fixing Brass full way valve gate with C.I. wheel of approved quality screwed end :32 mm nominal bore ---- etc., complete with all leadNos735.97735.9715.0FalseNoneNoneFalseNoneFalse11039.550
3046396102977NoneItem 13.4.3Providing and fixing Brass full way valve gate with C.I. wheel of approved quality screwed end : 40 mm nominal bore ---- etc., complete with all leadNos869.78869.7810.0FalseNoneNoneFalseNoneFalse8697.80
3046397102977NoneItem 13.4.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality screwed end 50 mm nominal bore ---- etc., complete with all leadNos1059.351059.358.0FalseNoneNoneFalseNoneFalse8474.80
3046398102977NoneItem 13.4.5Providing and fixing Brass full way valve gate with C.I. wheel of approved quality screwed end 65 mm nominal bore ---- etc., complete with all leadNos1748.231748.238.0FalseNoneNoneFalseNoneFalse13985.840
3046399102977NoneItem 7.3.3Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector FPC of size2120x1040x100mm and stainless steel hot water storage tank withstainless steel heat exchanger absorber made of copper sheet andcopper tube of following capacity aluminium box collector withappropriate capacity electrical back up rrangement excluding inletand out let pipes. SS Model with 100mm thick of 48KgorM3density Rock wool insulation with 22SWG Aluminium cladding 300 L ---- etc., complete with all leadEach86712.6586712.654.0FalseNoneNoneFalseNoneFalse346850.60
3046400102977NoneItem 13.50.5Providing and fixing Unplasticised Polyvinyl Chloride uPVC pipes, forcold water supply including all uPVC plain and brass threaded fittingsThis includes jointing of pipes and fittings with one step uPVC solventcement, trenching, refilling and testing of joints omplete as per directionof Engineer in Charge. External work 40mm dia pipes, From wash basin waste lines ---- etc., complete with all leadm380.42380.4248.0FalseNoneNoneFalseNoneFalse18260.160
3046401102977NoneItem 13.50.6Providing and fixing Unplasticised Polyvinyl Chloride uPVC pipes, forcold water supply including all uPVC plain and brass threaded fittingsThis includes jointing of pipes and fittings with one step uPVC solventcement, trenching, refilling and testing of joints omplete as per directionof Engineer in Charge. External work 50mm dia pipes, From sink and urinal waste lines ---- etc., complete with all leadm483.04483.0415.0FalseNoneNoneFalseNoneFalse7245.60
3046402102977NoneItem 13.64.1Providing and fixing Sewer SWR pipes, including all fittings, Thisincludes jointing of pipes and fittings with one step solvent cement,trenching, refilling and testing of joints complete as per direction ofEngineer in Charge. Internal drainage 75mm nominal dia pipes ---- etc., complete with all leadm361.65361.6578.0FalseNoneNoneFalseNoneFalse28208.70
3046403102977NoneItem 13.64.2Providing and fixing Sewer SWR pipes, including all fittings, Thisincludes jointing of pipes and fittings with one step solvent cement,trenching, refilling and testing of joints complete as per direction ofEngineer in Charge. Internal drainage 110mm nominal dia pipes ---- etc., complete with all leadm481.79481.7958.0FalseNoneNoneFalseNoneFalse27943.820
3046404102977NoneItem 13.63Providing and fixing PVC S.W.R Multi Floor Trap 10.0 cm X 7.5 cm X 5.0cm X 4.0 cm with all fitting arrangements and all necessary ccessoriescomplete ---- etc., complete with all leadEach305.34305.3435.0FalseNoneNoneFalseNoneFalse10686.90
3046405102977NoneItem 13.37Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc.with cement concrete 1:2:4 1 cement : 2 coarse sand : 4 graded stoneaggregate 20 mm nominal size, including finishing complete so as tomake it leak proof. ---- etc., complete with all leadEach391.69391.6920.0FalseNoneNoneFalseNoneFalse7833.80
3046406102977NoneItem 14.31Providing and fixing 600x450 mm beveled edge mirror of superior glassof approved quality complete with 6 mm thick hard board ground fixedto wooden cleats with C.P. brass screws and washers complete. ---- etc., complete with all leadEach1526.71526.712.0FalseNoneNoneFalseNoneFalse18320.40
3046407102977NoneItem 13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet 150 mm diameter ---- etc., complete with all leadNos349.14349.148.0FalseNoneNoneFalseNoneFalse2793.120
3046408102977NoneItem 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality and make as approved by Engineer in charge. ---- etc., complete with all leadEach6960.236960.238.0FalseNoneNoneFalseNoneFalse55681.840
3046409102977NoneItem 14.40.2Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings rrangement of approved quality and colour 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g ---- etc., complete with all leadEach620.69620.698.0FalseNoneNoneFalseNoneFalse4965.520
3046410102977NoneItem 14.38Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 g ---- etc., complete with all leadEach181.45181.458.0FalseNoneNoneFalseNoneFalse1451.60
3046411102977NoneItem 13.16Providing and fixing C.P. brass angle valve for basin mixer and geyserpoints of approved quality conforming to IS:8931 ---- etc., complete with all leadEach775.86775.8628.0FalseNoneNoneFalseNoneFalse21724.080
3046412102977NoneItem 14.2.1Providing and fixing white vitreous china pedestal type water closetEuropean type W.C. pan with seat and lid, 10 litre low level white P.V.C.flushing cistern, including flush pipe, with manually controlled devicehandle lever, conforming to IS : 7231, with all fittings and fixturescomplete, including cutting and making good the walls and floors whereverrequired : W.C. pan with ISI marked white solid plastic seat and li ---- etc., complete with all leadEach13631.3913631.3915.0FalseNoneNoneFalseNoneFalse204470.850
3046413102977NoneItem 14.4.1Providing and fixing white vitreous china flat back or wall corner typelipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flushpipe and C.P. brass spreaders with brass unions and G.I clamps complete,including painting of fittings and brackets, cutting and making good thewalls and floors wherever required: One urinal basin with 5 litre white P.V.C. automatic flushing cistern ---- etc., complete with all leadEach5573.695573.692.0FalseNoneNoneFalseNoneFalse11147.380
3046414102977NoneItem 13.15Providing and fixing C.P. brass stop cock concealed of standard design and of approved make conforming to IS:8931. ---- etc., complete with all leadNos907.26907.2640.0FalseNoneNoneFalseNoneFalse36290.40
3046415102977NoneItem 14.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps ---- etc., complete with all leadEach3856.783856.7814.0FalseNoneNoneFalseNoneFalse53994.920
3046416102977NoneItem 14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved qualityand make and as per the direction of Engineer-in-charge. ---- etc., complete with all leadEach1013.631013.6326.0FalseNoneNoneFalseNoneFalse26354.380
3046417102977NoneItem 13.8.1.1Providing and fixing unplasticised PVC connection pipe with brass unions :30 cm length 15 mm nominal bore ---- etc., complete with all leadEach103.87103.8728.0FalseNoneNoneFalseNoneFalse2908.360
3046418102977NoneItem 14.37.1Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effectivelength of tail pipe 260 mm from the centre of the waste coupling, 77 mmbreadth with 25 mm minimum water seal, weighing not less than 260 g ---- etc., complete with all leadEach382.93382.9326.0FalseNoneNoneFalseNoneFalse9956.180
3046419102977NoneItem 13.28.1Providing and fixing PTMT Waste Coupling for wash basin and sink, ofapproved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 g 15 mm nominal bore, weighing not less than 32 g ---- etc., complete with all leadNos80.0980.0928.0FalseNoneNoneFalseNoneFalse2242.520
3046420102977NoneItem 13.2.1Providing and fixing brass bib cock of approved quality 15 mm nominal bore ---- etc., complete with all leadNos357.9357.928.0FalseNoneNoneFalseNoneFalse10021.20
3046421102977NoneItem 9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete with all leadSqm5388.495388.4915.0FalseNoneNoneFalseNoneFalse80827.350
3046422102977NoneItem 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes,having thermal stability for hot and cold water supply, including all CPVCplain and brass threaded fittings, iorc fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes and fittings with one step CPVCsolvent cement and the cost of cutting chases and making good thesame including testing of joints complete as per direction of Engineer inCharge. Concealed work, including cutting chases and making good thewalls etc. 15 mm nominal dia Pipes ---- etc., complete with all leadm377.92377.9238.0FalseNoneNoneFalseNoneFalse14360.960
3046423102977NoneItem 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes,having thermal stability for hot and cold water supply, including all CPVCplain and brass threaded fittings, iorc fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes and fittings with one step CPVCsolvent cement and the cost of cutting chases and making good thesame including testing of joints complete as per direction of Engineer inCharge. Concealed work, including cutting chases and making good thewalls etc. 20 mm nominal dia Pipes ---- etc., complete with all leadm474.28474.2840.0FalseNoneNoneFalseNoneFalse18971.20
3046424102977NoneItem 13.32.3Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes,having thermal stability for hot and cold water supply, including all CPVCplain and brass threaded fittings, iorc fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes and fittings with one step CPVCsolvent cement and the cost of cutting chases and making good thesame including testing of joints complete as per direction of Engineer inCharge. Concealed work, including cutting chases and making good thewalls etc. 25 mm nominal dia pipes ---- etc., complete with all leadm596.91596.91146.0FalseNoneNoneFalseNoneFalse87148.860
3046425102977NoneItem 13.32.4Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes,having thermal stability for hot and old water supply, including all CPVC plain and brass threaded fittings, iorc fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes and fittings with one step CPVCsolvent cement and the cost of cutting chases and making good thesame including testing of joints complete as per direction of Engineer inCharge. Concealed work, including cutting chases and making good thewalls etc. 32 mm nominal dia pipes ---- etc., complete with all leadm710.83710.8360.0FalseNoneNoneFalseNoneFalse42649.80
3046426102977NoneItem 13.31.5Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes joiting of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 40 mm nominal dia Pipes ---- etc., complete with all leadm670.75670.7546.0FalseNoneNoneFalseNoneFalse30854.50
3046427102977NoneItem 13.31.6Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 50 mm nominal dia Pipes ---- etc., complete with all leadm977.34977.3430.0FalseNoneNoneFalseNoneFalse29320.20
3046428102977NoneItem Data RateAir Vent Cowel 75mm ---- etc., complete with all leadNos413.0413.015.0FalseNoneNoneFalseNoneFalse6195.00
3046429102977NoneItem Data RateAir Vent Cowel 110mm ---- etc., complete with all leadNos590.0590.010.0FalseNoneNoneFalseNoneFalse5900.00
3046430102977NoneItem Data rateSupplying and fixing Counter basin consisting of size: 420 x 590 x 195, Shape: oval of ISI or BIS Standards with a single 15mm C.P. 32mm dia CP waste coupling, 32mmdia heavy duty CP bottle trap with extension pipe, CP wall flanges, 2 Nos.15mm dia C.P. angle cocks, 2nos.C.P. flexible inlet connection pipes, CI brackets etc., complete including silicon sealant filling. Jaguar make or Equalent ---- etc., complete with all leadNos9318.469318.4622.0FalseNoneNoneFalseNoneFalse205006.120
3046431102977NoneItem Data RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit instant type CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. Jaguar make or Equalent ---- etc., complete with all leadNos2183.02183.031.0FalseNoneNoneFalseNoneFalse67673.00
17103318720000NoneNoneBuildingsEXTERNAL WATER SUPPLY AND DRAINAGE WORKS1931488.95
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3046432102978NoneItem 1.4Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & otherappurtenaces required to complete the work.In all kinds of soils Depth upto 1.5 m ---- etc., complete with all leadCum299.84299.84354.0FalseNoneNoneFalseNoneFalse106143.360
3046433102978NoneItem 1.11Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering,lead up to 50 m and lift upto 1.5 m. ---- etc., complete with all leadCum536.49536.49354.0FalseNoneNoneFalseNoneFalse189917.460
3046434102978NoneItem 10.3.7Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc.complete. for:Pipes of SN8 Self Fit - 160mm dia. ---- etc., complete with all leadm764.46764.46145.0FalseNoneNoneFalseNoneFalse110846.70
3046435102978NoneItem 10.3.8Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS contractor will make his own arrangements for procuring water for testing) etc. complete. for: Pipes of SN8 Self Fit - 200mm dia. ---- etc., complete with all leadm1102.711102.71125.0FalseNoneNoneFalseNoneFalse137838.750
3046436102978NoneItem 10.2.4Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS contractor will make his own arrangements for procuring water for testing) etc. complete for:Pipes of SN4, 160mm dia. ---- etc., complete with all leadm713.66713.66195.0FalseNoneNoneFalseNoneFalse139163.70
3046437102978NoneItem 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc.excluding the cost of CI frame and cover.. ---- etc., complete with all leadEach6757.516757.5128.0FalseNoneNoneFalseNoneFalse189210.280
3046438102978NoneItem 13.38Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber 100mm x 100mm size P type with Non Modular common burnt clay bricks of designation 3.5& water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: ---- etc., complete with all leadNos3137.153137.1520.0FalseNoneNoneFalseNoneFalse62743.00
3046439102978NoneItem 16.18.6Construction of RCC Machinehole chambers of 1:1.5:3 proportion or approved type Cast-insitu / Pre-cast RCC Machinehole chambers, constructed using form vibrators of standard type, with barricading, danger lighting and using of sight rails and boning rods wherever necessary, shoring and strutting wherever required using Ordinary Port Land Cement, using 1:1.5:3 proportion RCC with 20 mm and down graded jelly, well graded sand and steel of approved quality, 200 mm thick top concrete slab, having wall thickness and raft thickness as in approved drawings and with an offset in raft alround the chamber as in approved drawing, benching concrete with 1:6 slope towards the central drain finished smooth, including fixing and grouting of pipes, including conveying to work spot supply and fixing SFRC Machinehole cover and frame (Heavy duty) conforming to IS:12592 with latest amendments, on a bed of CC 1:2:4 Providing and fixing of minimum 3 mm thick encapsulated plastic footsteps (as per IS 10910) on 12 mm dia. Grade Fe-500 steel bar (as per IS 1786) staggered at 300 mm apart as detailed in Technical specifications, including stone grit beding wherever required, watering, curing, engraving Machinehole number with flow direction on the inner cylindrical surface etc., complete including cost of reinforcement steel and fabrication charges and also cost and conveyance of all materials, labour with all lead and lifts. The Pre-cast RCC Machinehole are for various diamters and depths as stated below and as per detailed drawings, specifications and direction of the Engineer. For 1.2m dia Machinehole: Constructing Pre-cast RCC Machinehole 1.2 m internal dia. ,3.0M depth & SFRC cover & frame ---- etc., complete with all leadNos97246.6397246.633.0FalseNoneNoneFalseNoneFalse291739.890
3046440102978NoneItem 13.23.5Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball 50 mm nominal bore, 242mm long, weighing not less than 1240 g ---- etc., complete with all leadNos1665.221665.223.0FalseNoneNoneFalseNoneFalse4995.660
3046441102978NoneItem 7.5.1Providing and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete. For DI/CI puddle flanges of 80mm dia. ---- etc., complete with all leadEach1957.621957.628.0FalseNoneNoneFalseNoneFalse15660.960
3046442102978NoneItem 7.5.2Providing and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete . For DI/CI puddle flanges of 100mm dia. ---- etc., complete with all leadEach2305.782305.786.0FalseNoneNoneFalseNoneFalse13834.680
3046443102978NoneItem 7.5.3Providing and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete. For DI/CI puddle flanges of 150mm dia. ---- etc., complete with all leadEach2935.192935.194.0FalseNoneNoneFalseNoneFalse11740.760
3046444102978NoneItem 7.5.5Providing and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete . For DI/CI puddle flanges of 250mm dia. ---- etc., complete with all leadEach5587.895587.893.0FalseNoneNoneFalseNoneFalse16763.670
3046445102978NoneItem 21.1.10Water purification plants: Supplying, Installation and Commissioning of automatic Water purification plant (RO+UF) with all accessories piping, product water tank on single phase power supply as per the enclosed detailed Technical Specifications including cost of material, loading and unloading and as directed by the Engineer in charge. (Ref- detailed specification enclosed seperatly). Note:- 1.The above rates mentioned are only for the preparation of estimate purpose. 2. All items are to be of BSI /NFS standards,with BSI / NFS mark . 3. Tenders to be invited for procurement. 4. No direct payment should be made under any situation or condition or on any account. 5. After commissioning of plant necessary testing to be done for the satisfactory of Engineer Incharge. Note : Refer the ANNEXURE : F for Detailed Specification of Each componentsFor (For 1000 LPH FRP : Skid) Type (HOSPITAL ) ---- etc., complete with all leadEach515424.0515424.01.0FalseNoneNoneFalseNoneFalse515424.00
3046446102978NoneItem 13.40.5Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. Sump To OHT (DOMESTIC) (Hospital) ) (3 HP, size 50x40 Head 30M, Discharge 198 LPM) ---- etc., complete with all leadEach23313.0223313.022.0FalseNoneNoneFalseNoneFalse46626.040
3046447102978NoneItem 13.32Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. ---- etc., complete with all leadJob8053.58053.52.0FalseNoneNoneFalseNoneFalse16107.00
3046448102978NoneItem 13.40.3Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest mendments.Sump To OHT (FLUSHING) (Hospital) (3 HP, size 50x40 Head 30M, Discharge 198 LPM) ---- etc., complete with all leadEach23313.0223313.022.0FalseNoneNoneFalseNoneFalse46626.040
3046449102978NoneItem 13.32Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. ---- etc., complete with all leadJob8053.58053.52.0FalseNoneNoneFalseNoneFalse16107.00
17103318720000NoneNoneBuildingsINTERNAL ELECTRIFICATION16406940.3
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3046450102979NoneItem 2.2.1Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit orcasing capping casing capping using 2x1.5Sqmm Phase and Neutral and 1x1.0 sqmm Earth wire FRLS multi strand PVC insulated copper wire confirming to IS-694: and latest amendments without control switch shall be fixed on the existing plastic sheetor gang box, the other end of the wires shall be terminated with sufficient loose length in a woodorPVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete with all leadEach333.29333.2915.0FalseNoneNoneFalseNoneFalse4999.350
3046451102979NoneItem 2.2.2Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit orcasing capping casing capping using 2x1.5Sqmm Phase and Neutral and 1x1.0 sqmm Earth wire FRLS multi strand PVC insulated copper wire confirming to IS-694: and latest amendments without control switch shall be fixed on the existing plastic sheetor gang box, the other end of the wires shall be terminated with sufficient loose length in a woodorPVC round block. complete for eacoutlet Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete with all leadEach469.58469.58143.0FalseNoneNoneFalseNoneFalse67149.940
3046452102979NoneItem 2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit orcasing capping casing capping using 2x1.5Sqmm Phase and Neutral and 1x1.0 sqmm Earth wire FRLS multi strand PVC insulated copper wire confirming to IS-694: and latest amendments without control switch shall be fixed on the existing plastic sheetor gang box, the other end of the wires shall be terminated with sufficient loose length in a woodorPVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete with all leadEach687.65687.65159.0FalseNoneNoneFalseNoneFalse109336.350
3046453102979NoneItem 2.2.4Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit orcasing capping casing capping using 2x1.5Sqmm Phase and Neutral and 1x1.0 sqmm Earth wire FRLS multi strand PVC insulated copper wire confirming to IS-694: and latest amendments without control switch shall be fixed on the existing plastic sheetor gang box, the other end of the wires shall be terminated with sufficient loose length in a woodorPVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches ---- etc., complete with all leadEach838.8838.866.0FalseNoneNoneFalseNoneFalse55360.80
3046454102979NoneItem 2.2.5Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit orcasing capping casing capping using 2x1.5Sqmm Phase and Neutral and 1x1.0 sqmm Earth wire FRLS multi strand PVC insulated copper wire confirming to IS-694: and latest amendments without control switch shall be fixed on the existing plastic sheetor gang box, the other end of the wires shall be terminated with sufficient loose length in a woodorPVC round block. complete for each outlet.Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switches ---- etc., complete with all leadEach1225.371225.37100.0FalseNoneNoneFalseNoneFalse122537.00
3046455102979NoneItem 3.4.1Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 1-2Way ---- etc., complete with all leadEach170.98170.98100.0FalseNoneNoneFalseNoneFalse17098.00
3046456102979NoneItem 3.4.2Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 3Way ---- etc., complete with all leadEach197.0197.0400.0FalseNoneNoneFalseNoneFalse78800.00
3046457102979NoneItem 3.4.3Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 4-5Way ---- etc., complete with all leadEach219.3219.355.0FalseNoneNoneFalseNoneFalse12061.50
3046458102979NoneItem 3.4.4Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 6Way ---- etc., complete with all leadEach272.58272.5838.0FalseNoneNoneFalseNoneFalse10358.040
3046459102979NoneItem 3.4.5Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 8 Way ---- etc., complete with all leadEach323.38323.3870.0FalseNoneNoneFalseNoneFalse22636.60
3046460102979NoneItem 3.4.6Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 10-12Way ---- etc., complete with all leadEach395.24395.2430.0FalseNoneNoneFalseNoneFalse11857.20
3046461102979NoneItem 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box. 1 to 2 Module ---- etc., complete with all leadEach169.74169.74100.0FalseNoneNoneFalseNoneFalse16974.00
3046462102979NoneItem 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box. 3 Module ---- etc., complete with all leadEach199.48199.48400.0FalseNoneNoneFalseNoneFalse79792.00
3046463102979NoneItem 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box. 4 Module ---- etc., complete with all leadEach216.83216.8355.0FalseNoneNoneFalseNoneFalse11925.650
3046464102979NoneItem 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box. 6 Module ---- etc., complete with all leadEach289.93289.9338.0FalseNoneNoneFalseNoneFalse11017.340
3046465102979NoneItem 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box. 8 Module ---- etc., complete with all leadEach351.88351.8870.0FalseNoneNoneFalseNoneFalse24631.60
3046466102979NoneItem 3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box. 10-12 Module ---- etc., complete with all leadEach426.22426.2230.0FalseNoneNoneFalseNoneFalse12786.60
3046467102979NoneItem 3.6.1Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc., complete with all leadEach126.38126.38504.0FalseNoneNoneFalseNoneFalse63695.520
3046468102979NoneItem 3.6.2Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch ---- etc., complete with all leadEach205.67205.6710.0FalseNoneNoneFalseNoneFalse2056.70
3046469102979NoneItem 3.6.3Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- etc., complete with all leadEach211.87211.87605.0FalseNoneNoneFalseNoneFalse128181.350
3046470102979NoneItem 3.6.4Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. ---- etc., complete with all leadEach442.32442.3263.0FalseNoneNoneFalseNoneFalse27866.160
3046471102979NoneItem 3.6.9Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc., complete with all leadEach403.91403.9110.0FalseNoneNoneFalseNoneFalse4039.10
3046472102979NoneItem 3.6.10Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6or16Amps universal socket ---- etc., complete with all leadEach296.4296.4532.0FalseNoneNoneFalseNoneFalse157684.80
3046473102979NoneItem 3.6.7Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch ---- etc., complete with all leadEach223.02223.02605.0FalseNoneNoneFalseNoneFalse134927.10
3046474102979NoneItem 1.13Supplyin and Fixing Metal Fan Box with Round Hook. ---- etc., complete with all leadNos144.96144.9663.0FalseNoneNoneFalseNoneFalse9132.480
3046475102979NoneItem 5.45.2Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB Without MCB.The entire plug and socket shall be mounted in a thermoplastic I powder coated metal box and wired Completely. SP and N 20Amps ---- etc., complete with all leadEach1203.071203.074.0FalseNoneNoneFalseNoneFalse4812.280
3046476102979NoneItem 5.45.4Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB Without MCB.The entire plug and socket shall be mounted in a thermoplastic I powder coated metal box and wired Completely. TP and N 30Amps ---- etc., complete with all leadEach2106.32106.34.0FalseNoneNoneFalseNoneFalse8425.20
3046477102979NoneItem 1.2.1Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 19or20mm dia 2mm thick ---- etc., complete with all leadm81.7781.77189.0FalseNoneNoneFalseNoneFalse15454.530
3046478102979NoneItem 1.2.2Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick ---- etc., complete with all leadm96.6496.647850.0FalseNoneNoneFalseNoneFalse758624.00
3046479102979NoneItem 1.2.3Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 32mm dia 2.5mm thick ---- etc., complete with all leadm127.62127.621870.0FalseNoneNoneFalseNoneFalse238649.40
3046480102979NoneItem 1.3.1Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19or20mm dia 2mm thick ---- etc., complete with all leadm84.2584.25110.0FalseNoneNoneFalseNoneFalse9267.50
3046481102979NoneItem 1.3.2Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thick ---- etc., complete with all leadm97.8897.882500.0FalseNoneNoneFalseNoneFalse244700.00
3046482102979NoneItem 1.3.3Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick ---- etc., complete with all leadm122.66122.662350.0FalseNoneNoneFalseNoneFalse288251.00
3046483102979NoneItem 1.4.7Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cableorconduit entry as required with one coat of primer of approved make etc.200 x 200 x 65 mm ---- etc., complete with all leadEach431.7431.740.0FalseNoneNoneFalseNoneFalse17268.00
3046484102979NoneItem 1.7.1Extra for Groove cutting in brick wallorCC floor to the suitable depth for concealing of ConduitorGI pipe and plastering, finishing upto wall surface complete.upto 50mm conduit in brick wall ---- etc., complete with all leadm35.9335.93100.0FalseNoneNoneFalseNoneFalse3593.00
3046485102979NoneItem 1.7.2Extra for Groove cutting in brick wallorCC floor to the suitable depth for concealing of ConduitorGI pipe and plastering, finishing upto wall surface complete.upto 50 mm conduit CC floor ---- etc., complete with all leadm85.4985.49100.0FalseNoneNoneFalseNoneFalse8549.00
3046486102979NoneItem 1.5.2Supplying and fixing PVCormetal conduit Deep junction box 25 mm deep Junction box ---- etc., complete with all leadEach69.3869.38645.0FalseNoneNoneFalseNoneFalse44750.10
3046487102979NoneItem 1.5.3Supplying and fixing PVCormetal conduit Deep junction box 32 mm deep Junction box ---- etc., complete with all leadEach75.5875.5860.0FalseNoneNoneFalseNoneFalse4534.80
3046488102979NoneItem 1.10.1Supplying PVCorGI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of thepi pe terminated completely 20mm ---- etc., complete with all leadm65.6765.67450.0FalseNoneNoneFalseNoneFalse29551.50
3046489102979NoneItem 1.10.2Supplying PVCorGI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of thepi pe terminated completely 25mm ---- etc., complete with all leadm89.2189.21623.0FalseNoneNoneFalseNoneFalse55577.830
3046490102979NoneItem 1.10.3Supplying PVCorGI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of thepi pe terminated completely 32mm ---- etc., complete with all leadm101.6101.6250.0FalseNoneNoneFalseNoneFalse25400.00
3046491102979NoneItem 1.10.5Supplying PVCorGI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of thepi pe terminated completely 50mm ---- etc., complete with all leadm153.64153.64200.0FalseNoneNoneFalseNoneFalse30728.00
3046492102979NoneItem 2.5.19Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and Virgin PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 -4C x 6 mm2 ---- etc., complete with all leadm406.39406.391350.0FalseNoneNoneFalseNoneFalse548626.50
3046493102979NoneItem 2.3.2Wiring for lightingorpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm ---- etc., complete with all leadm32.2132.217500.0FalseNoneNoneFalseNoneFalse241575.00
3046494102979NoneItem 2.3.3Wiring for lightingorpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm ---- etc., complete with all leadm52.0452.0411010.0FalseNoneNoneFalseNoneFalse572960.40
3046495102979NoneItem 2.3.4Wiring for lightingorpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm ---- etc., complete with all leadm78.0678.0616374.0FalseNoneNoneFalseNoneFalse1278154.440
3046496102979NoneItem 2.3.5Wiring for lightingorpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmm ---- etc., complete with all leadm113.99113.99250.0FalseNoneNoneFalseNoneFalse28497.50
3046497102979NoneItem 5.19.12Supplying and fixing regular MCB distribution boards on wallor wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 6 Way TP and N ---- etc., complete with all leadEach6120.666120.664.0FalseNoneNoneFalseNoneFalse24482.640
3046498102979NoneItem 5.19.13Supplying and fixing regular MCB distribution boards on wallor wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 8 Way TP and N ---- etc., complete with all leadEach7546.757546.752.0FalseNoneNoneFalseNoneFalse15093.50
3046499102979NoneItem 5.19.14Supplying and fixing regular MCB distribution boards on wallor wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 12 Way TP and N ---- etc., complete with all leadEach10822.6710822.676.0FalseNoneNoneFalseNoneFalse64936.020
3046500102979NoneItem 5.19.9Supplying and fixing regular MCB distribution boards on wallor wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 12 Way SP and N ---- etc., complete with all leadEach2885.632885.632.0FalseNoneNoneFalseNoneFalse5771.260
3046501102979NoneItem 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONorOFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP ---- etc., complete with all leadEach514.19514.19138.0FalseNoneNoneFalseNoneFalse70958.220
3046502102979NoneItem 5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONorOFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 Amps DP ---- etc., complete with all leadEach915.62915.6210.0FalseNoneNoneFalseNoneFalse9156.20
3046503102979NoneItem 5.18.5Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONorOFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40 Amps DP ---- etc., complete with all leadEach1313.341313.346.0FalseNoneNoneFalseNoneFalse7880.040
3046504102979NoneItem 5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONorOFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., complete with all leadEach3826.033826.0320.0FalseNoneNoneFalseNoneFalse76520.60
3046505102979NoneItem 5.20.1Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240or450V up to 300mA sensitivity on existing woodorpanel board 16-25 Amps 2 pole ---- etc., complete with all leadEach5299.25299.27.0FalseNoneNoneFalseNoneFalse37094.40
3046506102979NoneItem 5.20.5Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240or450V up to 300mA sensitivity on existing woodorpanel board 63 Amps 2 pole ---- etc., complete with all leadEach6514.666514.669.0FalseNoneNoneFalseNoneFalse58631.940
3046507102979NoneItem 5.20.10Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240or450V up to 300mA sensitivity on existing woodorpanel board 63 Amps 4 pole ---- etc., complete with all leadEach6870.266870.2616.0FalseNoneNoneFalseNoneFalse109924.160
3046508102979NoneItem 32.081.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 Part 1 or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 25 sqmm ---- etc., complete with all leadKm222826.72222826.720.3FalseNoneNoneFalseNoneFalse66848.0160
3046509102979NoneItem 5.46.1Supplying and fixing of Modular MCB Devices Tripper With Breaking capacity of 6kA. 16-32A SP ---- etc., complete with all leadEach260.19260.194.0FalseNoneNoneFalseNoneFalse1040.760
3046510102979NoneItem 5.46.4Supplying and fixing of Modular MCB Devices Tripper With Breaking capacity of 6kA. 16-32A SP ---- etc., complete with all leadEach993.68993.684.0FalseNoneNoneFalseNoneFalse3974.720
3046511102979NoneItem 32.151.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 Part 1 or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 120 sqmm ---- etc., complete with all leadKm566085.47566085.470.2FalseNoneNoneFalseNoneFalse113217.0940
3046512102979NoneItem 32.181.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 Part 1 or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 240 sqmm ---- etc., complete with all leadKm1068843.171068843.170.2FalseNoneNoneFalseNoneFalse213768.6340
3046513102979NoneItem 32.191.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 Part 1 or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 300 sqmm ---- etc., complete with all leadKm1320791.351320791.350.2FalseNoneNoneFalseNoneFalse264158.270
3046514102979NoneItem 32.201.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 Part 1 or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 400 sqmm ---- etc., complete with all leadKm1800848.091800848.090.4FalseNoneNoneFalseNoneFalse720339.2360
3046515102979NoneItem 21.05Laying of cable in Existing TrenchorGI pipeorStone WareorRCC Hume pipe using WoodenorAluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete with all leadKm25877.7525877.750.3FalseNoneNoneFalseNoneFalse7763.3250
3046516102979NoneItem 21.06Laying of cable in Existing TrenchorGI pipeorStone WareorRCC Hume pipe using WoodenorAluminum Rollers as directed by the departmental staff 35 sqmm to 95 sqmm ---- etc., complete with all leadKm38581.2238581.220.3FalseNoneNoneFalseNoneFalse11574.3660
3046517102979NoneItem 21.07Laying of cable in Existing TrenchorGI pipeorStone WareorRCC Hume pipe using WoodenorAluminum Rollers as directed by the departmental staff 120 sqmm to 240 sqmm ---- etc., complete with all leadKm39992.4439992.440.2FalseNoneNoneFalseNoneFalse7998.4880
3046518102979NoneItem 21.08Laying of cable in Existing TrenchorGI pipeorStone WareorRCC Hume pipe using WoodenorAluminum Rollers as directed by the departmental staff 300 sqmm to 400 sqmm ---- etc., complete with all leadKm42344.0642344.060.6FalseNoneNoneFalseNoneFalse25406.4360
3046519102979NoneItem 6.9Supplying and fixing of class A medium duty GI pipe of wall thick ness not less than 3.25mm on poleorwallordrain crossing with necessary clamping arrangements for UG cable of 1.1 KV class. ---- etc., complete with all leadm701.27701.2730.0FalseNoneNoneFalseNoneFalse21038.10
3046520102979NoneItem 6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class metal only 32mm dia ---- etc., complete with all leadEach144.96144.9620.0FalseNoneNoneFalseNoneFalse2899.20
3046521102979NoneItem 6.11.6Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class metal only 63mm dia ---- etc., complete with all leadEach480.73480.7325.0FalseNoneNoneFalseNoneFalse12018.250
3046522102979NoneItem 6.17.5Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 10 sqmm ---- etc., complete with all leadEach9.919.91160.0FalseNoneNoneFalseNoneFalse1585.60
3046523102979NoneItem 6.17.6Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sqmm ---- etc., complete with all leadEach15.4115.4180.0FalseNoneNoneFalseNoneFalse1232.80
3046524102979NoneItem 6.17.12Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 120 sqmm Long Barrel ---- etc., complete with all leadEach235.41235.4120.0FalseNoneNoneFalseNoneFalse4708.20
3046525102979NoneItem 6.17.15Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 240 sqmm Long Barrel ---- etc., complete with all leadEach573.66573.6640.0FalseNoneNoneFalseNoneFalse22946.40
3046526102979NoneItem 6.17.17Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 400 sqmm Long Barrel ---- etc., complete with all leadEach1173.331173.334.0FalseNoneNoneFalseNoneFalse4693.320
3046527102979NoneItem 12.57Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrode should be covered 150 mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. ---- etc., complete with all leadNos5273.185273.1820.0FalseNoneNoneFalseNoneFalse105463.60
3046528102979NoneItem 12.58.2Supplying and running of GIorCopper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip ---- etc., complete with all leadm101.6101.6200.0FalseNoneNoneFalseNoneFalse20320.00
3046529102979NoneItem 12.58.3Supplying and running of GIorCopper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI strip ---- etc., complete with all leadm158.59158.59150.0FalseNoneNoneFalseNoneFalse23788.50
3046530102979NoneItem 12.58.6Supplying and running of GIorCopper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm GI Plate. ---- etc., complete with all leadEach1084.131084.1310.0FalseNoneNoneFalseNoneFalse10841.30
3046531102979NoneItem 12.58.7Supplying and running of GIorCopper strips for grounding connections, using necessary fixing materials as required. 25x3mm Copper strip ---- etc., complete with all leadm706.23706.23120.0FalseNoneNoneFalseNoneFalse84747.60
3046532102979NoneItem 12.58.8Supplying and running of GIorCopper strips for grounding connections, using necessary fixing materials as required. strip 25x6mm Copper strip ---- etc., complete with all leadm1362.91362.9100.0FalseNoneNoneFalseNoneFalse136290.00
3046533102979NoneItem 12.58.11Supplying and running of GIorCopper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip 600x600x3mm Copper plate ---- etc., complete with all leadEach9194.629194.6210.0FalseNoneNoneFalseNoneFalse91946.20
3046534102979NoneItem 11.4.2Supplying of recess mounting non integrated type LED down light W luminaire comprising of pressure decastor extruded aluminium housing, with spring loaded false ceiling clamps, LED of PowerorCOB with CCT 6500 degree K, CRI70. efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS10322orIEC 60598, LM 79 and LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should5 of lamp Wage, short circuit and open circuit protection to be integrated in the circuit, THD less than 20, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABLorCPRI accredited laboratory with 2 years Warranty against any manufacturing defect working understandard electrical condition. 1012W ---- etc., complete with all leadEach1572.291572.2920.0FalseNoneNoneFalseNoneFalse31445.80
3046535102979NoneItem 11.4.3Supplying of recess mounting non integrated type LED down light W luminaire comprising of pressure decastor extruded aluminium housing, with spring loaded false ceiling clamps, LED of PowerorCOB with CCT 6500 degree K, CRI 70. efficacy 100 lumen per W, 120degree beam spread, life25000 burning hours and Compliance to IS10322orIEC 60598, LM 79 and LM 80. The lamp compart ment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp Wage, short circuit and open circuit protection to be integrated in the circuit, THD less than 20, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABLorCPRI accredited laboratory with 2 years Warranty against any manufacturing defect working understandard electrical condition. 1518W ---- etc., complete with all leadEach2070.372070.37262.0FalseNoneNoneFalseNoneFalse542436.940
3046536102979NoneItem 11.3.1Supplying of eet PVC Batten with integrated LED tubeW with high quality diffuser with Life of 25000 burning hours and 70 lumen maintenance with CRI 80. Power Input: 220240V at 50or60Hz and Power factor0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x2'- 9or10 w ---- etc., complete with all leadEach682.69682.6950.0FalseNoneNoneFalseNoneFalse34134.50
3046537102979NoneItem 11.3.2Supplying of feet PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours and 70% lumen maintenance with CRI 80. Power Input: 22040V at 50or60Hz and Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20or22 w ---- etc., complete with all leadEach854.91854.91150.0FalseNoneNoneFalseNoneFalse128236.50
3046538102979NoneItem 11.11.3Supplying and fixing of retrofit type LED bulbW with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life25000 burning hours and Compliance to IS 10322orIEC 60598, LM 79 and LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit and open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABLorCPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete with all leadEach184.61184.615.0FalseNoneNoneFalseNoneFalse923.050
3046539102979NoneItem 11.11.5Supplying and fixing of retrofit type - LED bulbW with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322orIEC 60598, LM 79 and LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit and open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABLorCPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K ---- etc., complete with all leadEach333.29333.295.0FalseNoneNoneFalseNoneFalse1666.450
3046540102979NoneItem 11.6.3Supplying of recess mounting nonintegral type LED W luminaire comprising of pressure decastorextruded aluminium housing, with spring loaded fase ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322orIEC 60598, LM 79 and LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit and open circuit protection to be integrated in the circuit, , THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABLor CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' 36watt ---- etc., complete with all leadEach5641.175641.17110.0FalseNoneNoneFalseNoneFalse620528.70
3046541102979NoneItem 11.8.3Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment and impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge ProtectionMin 5KV along with Over voltageor Overload, short circuitor misswiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50or60Hz application. Compliance to IS 10322orIEC 60598, LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiency130lmorw, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABLorCPRI and any Government certified agency and Design and Development facility certified by ISO 9001:2008 . Housing with supplier word mark orname shall be Engraved or Embossing on the die cast housingor Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer and CreeorNichiaor LumiledsorOsram make LED Source. LED Streetlight 70watts ---- etc., complete with all leadNos7424.097424.0920.0FalseNoneNoneFalseNoneFalse148481.80
3046542102979NoneItem 6.1Supplying exhaust fan of 1440 RPM of 300mm 12" size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete with all leadEach1848.591848.5930.0FalseNoneNoneFalseNoneFalse55457.70
3046543102979NoneItem 6.2.1Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 12" Sweep 300mm ---- etc., complete with all leadEach3678.593678.593.0FalseNoneNoneFalseNoneFalse11035.770
3046544102979NoneItem 6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearingsystem. 48" Sweep 1200 mm Regular model ---- etc., complete with all leadEach3697.183697.1863.0FalseNoneNoneFalseNoneFalse232922.340
3046545102979NoneItem 6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374or19 and also comply with IS: 1709or1984 with latest amendment, Rated voltage 220 Vor50 Hz, Rated power upto 35 W or 10 %, Rated current As per IS:374or19, Rated power factor 0.9 laggingmin, Rated speed 350 or 10% RPM, Rated air delivery 210 or 10% Cubic Meter Minimum, Rated service value 6.2 CMM or W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms 2M Ohms, Leakage current Should not exceed 210 Micro Amp, Power input, Wand current, Air Delivery and Fan Speed as per IS:374or2019 with latest amendment, 2year manufacturer Warranty. BLDC fans 48" Sweep 5 Star 1200 mm ---- etc., complete with all leadEach3316.83316.863.0FalseNoneNoneFalseNoneFalse208958.40
3046546102979NoneItem 12.46Supplying and Fixing of 70-150 Watts lamp holder 2 Pin ---- etc., complete with all leadEach78.0678.0620.0FalseNoneNoneFalseNoneFalse1561.20
3046547102979NoneItem 13.7.1Fixing all types and all capacities of fluorescent or false ceiling or spot light or CFL or LED fittings indoor on the wall or ceiling or rafters or girders using 23or0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall or ceiling or Rafter or Girders ---- etc., complete with all leadEach151.16151.16472.0FalseNoneNoneFalseNoneFalse71347.520
3046548102979NoneItem 13.11Fixing a ceiling or wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 or 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. ---- etc., complete with all leadEach390.29390.2963.0FalseNoneNoneFalseNoneFalse24588.270
3046549102979NoneItem 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 or 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete with all leadEach875.97875.9733.0FalseNoneNoneFalseNoneFalse28907.010
3046550102979NoneItem 13.19Fixing all types and all capacities of 1'x4' or 2'x2' LED Light fittings indoor on the wall or ceiling or rafters or girders with necessary supporting frame, using 2310.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps. ---- etc., complete with all leadEach607.11607.11110.0FalseNoneNoneFalseNoneFalse66782.10
3046551102979NoneItem 13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts and nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc., complete with all leadEach1810.81810.810.0FalseNoneNoneFalseNoneFalse18108.00
3046552102979NoneItem 13.2.2Supplying and Fixing........mm dia clampsss A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MVorSVorMHorFTL street light fitting of all capacities on railorRCCorwallortubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires.Using 32mm dia G.I.Pipe ---- etc., complete with all leadEach1604.511604.5120.0FalseNoneNoneFalseNoneFalse32090.20
3046553102979NoneItem 13.5Fixing halogenormetal halide or SVL or IL or LED floodlight fitting over existing pole or wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete with all leadEach200.72200.7220.0FalseNoneNoneFalseNoneFalse4014.40
3046554102979NoneItem 5.42.1Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 14SWG ---- etc., complete with all leadSq CM0.620.62450000.0FalseNoneNoneFalseNoneFalse279000.00
3046555102979NoneItem 5.40.5Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRPorDMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 1000 A double run of 4 x 60 x 10 mm Aluminium Strips ---- etc., complete with all leadm13108.6213108.628.0FalseNoneNoneFalseNoneFalse104868.960
3046556102979NoneItem 5.41.2Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x50x6mm ---- etc., complete with all leadm489.41489.4110.0FalseNoneNoneFalseNoneFalse4894.10
3046557102979NoneItem 5.41.3Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75x75x6mm ---- etc., complete with all leadm687.65687.656.0FalseNoneNoneFalseNoneFalse4125.90
3046558102979NoneItem 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C Channel ---- etc., complete with all leadm936.68936.6810.0FalseNoneNoneFalseNoneFalse9366.80
3046559102979NoneItem 5.41.5Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75x150x75x6mm C channel ---- etc., complete with all leadm1147.311147.316.0FalseNoneNoneFalseNoneFalse6883.860
3046560102979NoneItem 5.15.9Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing woodorpanel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. Icu=100% lcs. In 4P MCCB, all Poles should have protection for Short-CicrcuitorOver Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open. Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE100Amps 25kA ---- etc., complete with all leadEach10515.3910515.392.0FalseNoneNoneFalseNoneFalse21030.780
3046561102979NoneItem 5.15.13Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing woodorpanel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. Icu=100% lcs. In 4P MCCB, all Poles should have protection for Short-CicrcuitorOver Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open. Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE 250Amps 35kA ---- etc., complete with all leadEach26503.4526503.453.0FalseNoneNoneFalseNoneFalse79510.350
3046562102979NoneItem 5.15.20Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing woodorpanel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Therm IS-13947. Icu=100% lcs. In 4P MCCB, all Poles should have protection for Short-CicrcuitorOver Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open. Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE700-800Amps 50kA ---- etc., complete with all leadEach61826.161826.13.0FalseNoneNoneFalseNoneFalse185478.30
3046563102979NoneItem 5.18Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONorOFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63A TPN ---- etc., complete with all leadEach3826.033826.037.0FalseNoneNoneFalseNoneFalse26782.210
3046564102979NoneItem 5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete with all leadEach11541.2911541.292.0FalseNoneNoneFalseNoneFalse23082.580
3046565102979NoneItem 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12or24v D.C ---- etc., complete with all leadEach638.09638.099.0FalseNoneNoneFalseNoneFalse5742.810
3046566102979NoneItem 5.34Supplying, fixing and wiring 50or5 to 400or5Amps 15VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., complete with all leadEach696.32696.329.0FalseNoneNoneFalseNoneFalse6266.880
3046567102979NoneItem 5.12.8Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. SM Enclosure Sheet Metal Execution 800A ---- etc., complete with all leadEach72068.9172068.911.0FalseNoneNoneFalseNoneFalse72068.910
3046568102979NoneItem 5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delayorautoor manual reset facility suitable to mount on DIN railor flush mounting on panel board. ---- etc., complete with all leadEach11466.9511466.953.0FalseNoneNoneFalseNoneFalse34400.850
3046569102979NoneItem 5.16Suppiying and fixing of Shunt trip suitable for MCCB.CBCT ---- etc., complete with all leadEach2110.022110.022.0FalseNoneNoneFalseNoneFalse4220.040
3046570102979NonePWD SR 2023-24 V-6 Page No-20 It No-5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete with all leadSq CM0.530.53125000.0FalseNoneNoneFalseNoneFalse66250.00
3046571102979NonePWD SR 2023-24 V-6 Page No-20 It No-5.40.2Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete with all leadm4255.974255.971.5FalseNoneNoneFalseNoneFalse6383.9550
3046572102979NonePWD SR 2023-24 V-6 Page No-20 It No-5.41.2Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x50x6mm ---- etc., complete with all leadm489.41489.416.0FalseNoneNoneFalseNoneFalse2936.460
3046573102979NonePWD SR 2023-24 V-6 Page No-20 It No-5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete with all leadm936.68936.686.0FalseNoneNoneFalseNoneFalse5620.080
3046574102979NonePWD SR 2023-24 V-6 Page No-17 It No-5.15.13Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE100Amps 25kA 250Amps 35kA ---- etc., complete with all leadEach26503.4526503.451.0FalseNoneNoneFalseNoneFalse26503.450
3046575102979NonePWD SR 2023-24 V-6 Page No-17 It No-5.18.7Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps TPN ---- etc., complete with all leadEach2127.362127.362.0FalseNoneNoneFalseNoneFalse4254.720
3046576102979NonePWD SR 2023-24 V-6 Page No-17 It No-5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40Amps TPN ---- etc., complete with all leadEach3771.523771.526.0FalseNoneNoneFalseNoneFalse22629.120
3046577102979NonePWD SR 2023-24 V-6 Page No-17 It No-5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP ---- etc., complete with all leadEach514.19514.193.0FalseNoneNoneFalseNoneFalse1542.570
3046578102979NonePWD SR 2023-24 V-6 Page No-19 It No-5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete with all leadEach11541.2911541.291.0FalseNoneNoneFalseNoneFalse11541.290
3046579102979NonePWD SR 2023-24 V-6 Page No-19 It No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete with all leadEach638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3046580102979NonePWD SR 2023-24 V-6 Page No-19 It No-5.34Supplying, fixing and wiring 50/5 to 400/5Amps 15VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., complete with all leadEach696.32696.323.0FalseNoneNoneFalseNoneFalse2088.960
3046581102979NonePWD SR 2023-24 V-6 Page No-19 It No-5.39Supplying, fixing and wiring Automatic Power Factor controller fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three place LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect I disconnect banks, with automatic recognition or with standard programs. ---- etc., complete with all leadEach26811.9626811.961.0FalseNoneNoneFalseNoneFalse26811.960
3046582102979NonePWD SR 2023-24 V-6 Page No-19 It No-5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery ---- etc., complete with all leadKvar594.72594.72100.0FalseNoneNoneFalseNoneFalse59472.00
3046583102979NonePWD SR 2023-24 V-6 Page No-15 It No-5.13.1Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 Amps ---- etc., complete with all leadEach1598.311598.312.0FalseNoneNoneFalseNoneFalse3196.620
3046584102979NonePWD SR 2023-24 V-6 Page No-15 It No-5.13.2Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 40 Amps ---- etc., complete with all leadEach2797.662797.666.0FalseNoneNoneFalseNoneFalse16785.960
3046585102979NoneLeast Quotation RateSupplying , & fixing of 6A, 3 Position, Auto-Manual Selector Switch in existing Panel ---- etc., complete with all leadEach531.0531.06.0FalseNoneNoneFalseNoneFalse3186.00
3046586102979NonePWD SR 2023-24 V-6 Page No-20 It No-5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour etc., complete 16SWG ---- etc., complete with all leadSq CM0.530.53200000.0FalseNoneNoneFalseNoneFalse106000.00
3046587102979NonePWD SR 2023-24 V-6 Page No-20 It No-5.40.2Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete with all leadm4255.974255.973.0FalseNoneNoneFalseNoneFalse12767.910
3046588102979NonePWD SR 2023-24 V-6 Page No-20 It No-5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete with all leadm377.9377.912.0FalseNoneNoneFalseNoneFalse4534.80
3046589102979NonePWD SR 2023-24 V-6 Page No-20 It No-5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete with all leadm936.68936.6812.0FalseNoneNoneFalseNoneFalse11240.160
3046590102979NonePWD SR 2023-24 V-6 Page No-17 It No-5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE100Amps 25kA ---- etc., complete with all leadEach10515.3910515.392.0FalseNoneNoneFalseNoneFalse21030.780
3046591102979NonePWD SR 2023-24 V-6 Page No-17 It No-5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP ---- etc., complete with all leadEach514.19514.194.0FalseNoneNoneFalseNoneFalse2056.760
3046592102979NonePWD SR 2023-24 V-6 Page No-18 It No-5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., complete with all leadEach3826.033826.033.0FalseNoneNoneFalseNoneFalse11478.090
3046593102979NonePWD SR 2023-24 V-6 Page No-19 It No-5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete with all leadEach11541.2911541.291.0FalseNoneNoneFalseNoneFalse11541.290
3046594102979NonePWD SR 2023-24 V-6 Page No-19 It No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete with all leadEach638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3046595102979NonePWD SR 2023-24 V-6 Page No-19 It No-5.34Supplying, fixing and wiring 50/5 to 400/5Amps 15VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., complete with all leadEach696.32696.323.0FalseNoneNoneFalseNoneFalse2088.960
3046596102979NonePWD SR 2023-24 V-6 Page No-20 It No-5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete with all leadSq CM0.530.53200000.0FalseNoneNoneFalseNoneFalse106000.00
3046597102979NonePWD SR 2023-24 V-6 Page No-20 It No-5.40.2Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete with all leadm4255.974255.973.0FalseNoneNoneFalseNoneFalse12767.910
3046598102979NonePWD SR 2023-24 V-6 Page No-20 It No-5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete with all leadm377.9377.912.0FalseNoneNoneFalseNoneFalse4534.80
3046599102979NonePWD SR 2023-24 V-6 Page No-20 It No-5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete with all leadm936.68936.6812.0FalseNoneNoneFalseNoneFalse11240.160
3046600102979NonePWD SR 2023-24 V-6 Page No-17 It No-5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP ---- etc., complete with all leadEach514.19514.194.0FalseNoneNoneFalseNoneFalse2056.760
3046601102979NonePWD SR 2023-24 V-6 Page No-18 It No-5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., complete with all leadEach3826.033826.033.0FalseNoneNoneFalseNoneFalse11478.090
3046602102979NonePWD SR 2023-24 V-6 Page No-19 It No-5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete with all leadEach11541.2911541.291.0FalseNoneNoneFalseNoneFalse11541.290
3046603102979NonePWD SR 2023-24 V-6 Page No-19 It No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete with all leadEach638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3046604102979NonePWD SR 2023-24 V-6 Page No-19 It No-5.34Supplying, fixing and wiring 50/5 to 400/5Amps 15VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., complete with all leadEach696.32696.323.0FalseNoneNoneFalseNoneFalse2088.960
3046605102979NonePWD SR 2023-24 V-6 Page No-20 It No-5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour etc., complete 16SWG ---- etc., complete with all leadSq CM0.530.53240000.0FalseNoneNoneFalseNoneFalse127200.00
3046606102979NonePWD SR 2023-24 V-6 Page No-20 It No-5.42.3Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete with all leadm5507.365507.363.0FalseNoneNoneFalseNoneFalse16522.080
3046607102979NonePWD SR 2023-24 V-6 Page No-20 It No-5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete with all leadm377.9377.912.0FalseNoneNoneFalseNoneFalse4534.80
3046608102979NonePWD SR 2023-24 V-6 Page No-20 It No-5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete with all leadm936.68936.6812.0FalseNoneNoneFalseNoneFalse11240.160
3046609102979NonePWD SR 2023-24 V-6 Page No-17 It No-5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE100Amps 25kA ---- etc., complete with all leadEach10515.3910515.392.0FalseNoneNoneFalseNoneFalse21030.780
3046610102979NonePWD SR 2023-24 V-6 Page No-17 It No-5.15.10Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE 125Amps 25kA ---- etc., complete with all leadEach12812.512812.51.0FalseNoneNoneFalseNoneFalse12812.50
3046611102979NonePWD SR 2023-24 V-6 Page No-17 It No-5.15.11Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE 160Amps 25kA ---- etc., complete with all leadEach16660.8316660.831.0FalseNoneNoneFalseNoneFalse16660.830
3046612102979NonePWD SR 2023-24 V-6 Page No-17 It No-5.15.17Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Therm IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE320-400Amps 50kA ---- etc., complete with all leadEach37307.5337307.531.0FalseNoneNoneFalseNoneFalse37307.530
3046613102979NonePWD SR 2023-24 V-6 Page No-17 It No-5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP ---- etc., complete with all leadEach514.19514.192.0FalseNoneNoneFalseNoneFalse1028.380
3046614102979NonePWD SR 2023-24 V-6 Page No-19 It No-5.34Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40Amps TPN ---- etc., complete with all leadEach3771.523771.522.0FalseNoneNoneFalseNoneFalse7543.040
3046615102979NonePWD SR 2023-24 V-6 Page No-18 It No-5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., complete with all leadEach3826.033826.031.0FalseNoneNoneFalseNoneFalse3826.030
3046616102979NonePWD SR 2023-24 V-6 Page No-19 It No-5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete with all leadEach11541.2911541.291.0FalseNoneNoneFalseNoneFalse11541.290
3046617102979NonePWD SR 2023-24 V-6 Page No-19 It No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete with all leadEach638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3046618102979NonePWD SR 2023-24 V-6 Page No-19 It No-5.34Supplying, fixing and wiring 50/5 to 400/5Amps 15VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., complete with all leadEach696.32696.323.0FalseNoneNoneFalseNoneFalse2088.960
3046619102979NonePWD SR 2023-24 V-6 Page No-20 It No-5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour etc., complete 16SWG ---- etc., complete with all leadSq CM0.530.53240000.0FalseNoneNoneFalseNoneFalse127200.00
3046620102979NonePWD SR 2023-24 V-6 Page No-20 It No-5.40.2Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete with all leadm4255.974255.973.0FalseNoneNoneFalseNoneFalse12767.910
3046621102979NonePWD SR 2023-24 V-6 Page No-20 It No-5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete with all leadm377.9377.912.0FalseNoneNoneFalseNoneFalse4534.80
3046622102979NonePWD SR 2023-24 V-6 Page No-20 It No-5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete with all leadm936.68936.6812.0FalseNoneNoneFalseNoneFalse11240.160
3046623102979NonePWD SR 2023-24 V-6 Page No-17 It No-5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE100Amps 25kA ---- etc., complete with all leadEach10515.3910515.394.0FalseNoneNoneFalseNoneFalse42061.560
3046624102979NonePWD SR 2023-24 V-6 Page No-17 It No-5.15.10Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE 125Amps 25kA ---- etc., complete with all leadEach12812.512812.51.0FalseNoneNoneFalseNoneFalse12812.50
3046625102979NonePWD SR 2023-24 V-6 Page No-17 It No-5.15.17Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Therm IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE320-400Amps 50kA ---- etc., complete with all leadEach37307.5337307.531.0FalseNoneNoneFalseNoneFalse37307.530
3046626102979NonePWD SR 2023-24 V-6 Page No-17 It No-5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP ---- etc., complete with all leadEach514.19514.191.0FalseNoneNoneFalseNoneFalse514.190
3046627102979NonePWD SR 2023-24 V-6 Page No-17 It No-5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40Amps TPN ---- etc., complete with all leadEach3771.523771.523.0FalseNoneNoneFalseNoneFalse11314.560
3046628102979NonePWD SR 2023-24 V-6 Page No-19 It No-5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete with all leadEach11541.2911541.291.0FalseNoneNoneFalseNoneFalse11541.290
3046629102979NonePWD SR 2023-24 V-6 Page No-19 It No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete with all leadEach638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3046630102979NonePWD SR 2023-24 V-6 Page No-19 It No-5.34Supplying, fixing and wiring 50/5 to 400/5Amps 15VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., complete with all leadEach696.32696.323.0FalseNoneNoneFalseNoneFalse2088.960
3046631102979NonePWD SR 2023-24 V-6 Page No-20 It No-5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour etc., complete 16SWG ---- etc., complete with all leadSq CM0.530.5350000.0FalseNoneNoneFalseNoneFalse26500.00
3046632102979NonePWD SR 2023-24 V-6 Page No-20 It No-5.40.2Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete with all leadm4255.974255.972.0FalseNoneNoneFalseNoneFalse8511.940
3046633102979NonePWD SR 2023-24 V-6 Page No-20 It No-5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete with all leadm377.9377.96.0FalseNoneNoneFalseNoneFalse2267.40
3046634102979NonePWD SR 2023-24 V-6 Page No-20 It No-5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete with all leadm936.68936.686.0FalseNoneNoneFalseNoneFalse5620.080
3046635102979NonePWD SR 2023-24 V-6 Page No-17 It No-5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE100Amps 25kA ---- etc., complete with all leadEach10515.3910515.395.0FalseNoneNoneFalseNoneFalse52576.950
3046636102979NonePWD SR 2023-24 V-6 Page No-17 It No-5.15.13Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE 250 A 25 kA ---- etc., complete with all leadEach26503.4526503.451.0FalseNoneNoneFalseNoneFalse26503.450
3046637102979NonePWD SR 2023-24 V-6 Page No-17 It No-5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP ---- etc., complete with all leadEach514.19514.194.0FalseNoneNoneFalseNoneFalse2056.760
3046638102979NonePWD SR 2023-24 V-6 Page No-18 It No-5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., complete with all leadEach3826.033826.0310.0FalseNoneNoneFalseNoneFalse38260.30
3046639102979NonePWD SR 2023-24 V-6 Page No-19 It No-5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete with all leadEach11541.2911541.291.0FalseNoneNoneFalseNoneFalse11541.290
3046640102979NonePWD SR 2023-24 V-6 Page No-19 It No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete with all leadEach638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3046641102979NonePWD SR 2023-24 V-6 Page No-19 It No-5.34Supplying, fixing and wiring 50/5 to 400/5Amps 15VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., complete with all leadEach696.32696.323.0FalseNoneNoneFalseNoneFalse2088.960
3046642102979NonePWD SR 2023-24 V-6 Page No-20 It No-5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour etc., complete 16SWG ---- etc., complete with all leadSq CM0.530.5350000.0FalseNoneNoneFalseNoneFalse26500.00
3046643102979NonePWD SR 2023-24 V-6 Page No-20 It No-5.40.1Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.100Amps 4x30x6mm Aluminum Strips ---- etc., complete with all leadm3054.143054.141.0FalseNoneNoneFalseNoneFalse3054.140
3046644102979NonePWD SR 2023-24 V-6 Page No-20 It No-5.40.2Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete with all leadm4255.974255.971.0FalseNoneNoneFalseNoneFalse4255.970
3046645102979NonePWD SR 2023-24 V-6 Page No-20 It No-5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete with all leadm377.9377.93.0FalseNoneNoneFalseNoneFalse1133.70
3046646102979NonePWD SR 2023-24 V-6 Page No-20 It No-5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete with all leadm936.68936.683.0FalseNoneNoneFalseNoneFalse2810.040
3046647102979NonePWD SR 2023-24 V-6 Page No-17 It No-5.15.13Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE 250Amps 35kA ---- etc., complete with all leadEach26503.4526503.451.0FalseNoneNoneFalseNoneFalse26503.450
3046648102979NonePWD SR 2023-24 V-6 Page No-17 It No-5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE100Amps 25kA ---- etc., complete with all leadEach10515.3910515.392.0FalseNoneNoneFalseNoneFalse21030.780
3046649102979NonePWD SR 2023-24 V-6 Page No-19 It No-5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete with all leadEach11541.2911541.291.0FalseNoneNoneFalseNoneFalse11541.290
3046650102979NonePWD SR 2023-24 V-6 Page No-19 It No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete with all leadEach638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3046651102979NonePWD SR 2023-24 V-6 Page No-19 It No-5.34Supplying, fixing and wiring 50/5 to 400/5Amps 15VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., complete with all leadEach696.32696.323.0FalseNoneNoneFalseNoneFalse2088.960
3046652102979NonePWD SR 2023-24 V-6 Page No-20 It No-5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete with all leadSq CM0.530.5380000.0FalseNoneNoneFalseNoneFalse42400.00
3046653102979NonePWD SR 2023-24 V-6 Page No-20 It No-5.40.2Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete with all leadm4255.974255.972.0FalseNoneNoneFalseNoneFalse8511.940
3046654102979NonePWD SR 2023-24 V-6 Page No-20 It No-5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete with all leadm377.9377.98.0FalseNoneNoneFalseNoneFalse3023.20
3046655102979NonePWD SR 2023-24 V-6 Page No-20 It No-5.41.6Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete with all leadm936.68936.688.0FalseNoneNoneFalseNoneFalse7493.440
3046656102979NonePWD SR 2023-24 V-6 Page No-17 It No-5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 100Amps 25kA ---- etc., complete with all leadEach10515.3910515.393.0FalseNoneNoneFalseNoneFalse31546.170
3046657102979NonePWD SR 2023-24 V-6 Page No-17 It No-5.15.10Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE 125Amps 25kA ---- etc., complete with all leadEach12812.512812.53.0FalseNoneNoneFalseNoneFalse38437.50
3046658102979NonePWD SR 2023-24 V-6 Page No-17 It No-5.15.13Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE 250Amps 35kA ---- etc., complete with all leadEach26503.4526503.452.0FalseNoneNoneFalseNoneFalse53006.90
3046659102979NonePWD SR 2023-24 V-6 Page No-17 It No-5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP ---- etc., complete with all leadEach514.19514.197.0FalseNoneNoneFalseNoneFalse3599.330
3046660102979NonePWD SR 2023-24 V-6 Page No-19 It No-5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete with all leadEach11541.2911541.292.0FalseNoneNoneFalseNoneFalse23082.580
3046661102979NonePWD SR 2023-24 V-6 Page No-19 It No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete with all leadEach638.09638.096.0FalseNoneNoneFalseNoneFalse3828.540
3046662102979NonePWD SR 2023-24 V-6 Page No-19 It No-5.34Supplying, fixing and wiring 50/5 to 400/5Amps 15VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., complete with all leadEach696.32696.326.0FalseNoneNoneFalseNoneFalse4177.920
3046663102979NonePWD SR 2023-24 V-6 Page No-20 It No-5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour etc., complete 16SWG ---- etc., complete with all leadSq CM0.530.53160000.0FalseNoneNoneFalseNoneFalse84800.00
3046664102979NonePWD SR 2023-24 V-6 Page No-17 It No-5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 100Amps 25kA ---- etc., complete with all leadEach10515.3910515.393.0FalseNoneNoneFalseNoneFalse31546.170
3046665102979NonePWD SR 2023-24 V-6 Page No-11 It No-4.1.1Fabricating, supplying and erecting swaged tubular pole of height …Mtr having three sections, and providing two coats of red oxide paint and finished with two coats of enamelled paint of approved quality and colour and M.S. base plate of suitable size welded at the bottom of the pole(as per IS) and 40mm dia GI / flexible PVC pipe of 1 mtr length fitted to the heavy gauge polycarbonate control box including 5way connector of size 167x125x82mm for 7.5M pole/200x160x98mm for remaining length of pole with front opening cover, with locking arrangements and suitable capacity MCB / DP switch, The pole shall be erected in cement concrete work (1:2:4) including excavation and refilling of planting depth of the pole to the ground level and the coping CC shall be up to 0.6M above ground level as per IS 2713 - 7. Erection of heavy duty pole on Footpath / median 9Mt (5Mt Hb,165.1mm dia 4.85mm thick x2M Hm, 139.7mm dia 4.50mm thick x 2M Ht,114.3mm dia 3.65mm thick) as per IS 410 SP 32 ---- etc., complete with all leadEach19204.519204.520.0FalseNoneNoneFalseNoneFalse384090.00
3046666102979NonePWD SR 2023-24 V-6 Page No-46 It No-11.8.3Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT Graterthan 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire Graterthan IK08. Power Factor Graterthan0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED EfficiencyGraterthan130lm/w, nominal CRI Graterthan75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 70watts ---- etc., complete with all leadNo7424.097424.0920.0FalseNoneNoneFalseNoneFalse148481.80
3046667102979NonePWD SR 2023-24 13.2.2Supplying and Fixing........mm dia clampsss A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires.Using 32mm dia G.I.Pipe ---- etc., complete with all leadEach1604.511604.5120.0FalseNoneNoneFalseNoneFalse32090.20
3046668102979NonePWD SR 2023-24 V-6 Page No-47 It No-11.12.2Supply of LED Bollard light fitting of ...W with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT Graterthan 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire Graterthan IK08. Power Factor Graterthan0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB, with 2 years Warranty against any manufacturing defect working under standard electrical condition. 8W 1 Mtr Height ---- etc., complete with all leadEach5611.375611.3714.0FalseNoneNoneFalseNoneFalse78559.180
3046669102979NonePWD SR 2023-24 V-6 Page No-56 It No-13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete with all leadEach200.72200.7220.0FalseNoneNoneFalseNoneFalse4014.40
3046670102979NoneLeast Quotation RateSupply of 08 KVA Isolated Power Distribution panel for OT with Online monitoring, with fault location and with Programmable Remote Alarm Indicator : Electrical Safety system: IEC 60364-7-710: “Electrical installation ofbuildings-Requirements for special installations for medical locations”( Group-2) and Indian NEC- SP-30- Section 4, 2011, provision P5 requires unearthed(IT) system for all critical medical locations ( O.T, I.C.U, I.C.C.U, PrematureBaby Room etc). Therefore, an Electrical Safety Alarm System shall beinstalled to ensure patient and employee safety against risk of electrical shock, fire and damage of electrical insulation used in equipment and powerdistribution circuits. The system shall provide perfect ungrounded powersupply system in OT; ensure no fire, no electrical spark, no MCB tripping evenin case of 1st insulation fault (BIS NEC-SP-30 , P5 location requirement);ensure 24X7 Insulation monitoring of entire electrical distribution system &an audio visual remote and local alarm even in case of 1st fault; never give anyspurious alarm / false alarm, fool proof against EMI/EMC effects; should havea system to identify faulty feeder / socket / equipment online without trippingthe system; a periodic self diagnostic features to identify malfunctions in thesystem itself. Insulation monitoring devices using a Active measuring principle in compliance with IEC 61557-8&IEC-60364-7-710 should be used.Insulation monitor shall have facility to monitor over current and temperature monitoring facility of the Isolation transformer.Fault Location system should be in accordance with IEC 61557-9 & IEC 60364-7-710. a.An Isolation Transformer 10KVA max as per IEC-61558-2 & IEC-60364-7-710 along with insulation monitoring device& fault location system shall be provided as mentioned above. Supplier/ Vender to quote necessary hardware to fulfill the requirement. b.A complete panel consisting of all items along with indicating lamp for (Mains On, Healthy & Faulty condition), MCBs, Exhaust Fan and air filter shall be supplied. All internal wiring should terminate in connectors with screw and clampspring connections of the Klippon type mounted, on a DIN rail and labeledwith indelible proprietary labels. Individual fuses or miniature circuitbreakers should protect all internal circuits. All internal wiring should be ofthe high temperature type and enclosed in propriety ducting or mini. Allinternal wires should be marked with plastic ferrule type cable markers, forease of identification.Bender Make or Equivalent. ---- etc., complete with all leadEach1318060.01318060.02.0FalseNoneNoneFalseNoneFalse2636120.00
3046671102979NonePWD SR 2023-24 V-6 Page No-18 It No-5.19.11upplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 4 Way TPN Double door ---- etc., complete with all leadEach5003.085003.081.0FalseNoneNoneFalseNoneFalse5003.080
3046672102979NonePWD SR 2023-24 V-6 Page No-17 It No-5.18.7Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps TPN ---- etc., complete with all leadEach2127.362127.361.0FalseNoneNoneFalseNoneFalse2127.360
3046673102979NonePWD SR 2023-24 V-6 Page No-17 It No-5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 Amps DP ---- etc., complete with all leadEach915.62915.623.0FalseNoneNoneFalseNoneFalse2746.860
3046674102979NonePWD SR 2023-24 V-6 Page No-21 It No-5.47Supplying and fixing Microprocessor based Electronic timer (without contactor, Din Mounting using necessary bolts, nuts and washers etc.,.) 3-120sec setting. ---- etc., complete with all leadEach2868.292868.291.0FalseNoneNoneFalseNoneFalse2868.290
3046675102979NonePWD SR 2023-24 V-6 Page No-21 It No-5.49.3Supplying and fixing of solar Lux level street light control switch single phase including suitable capacity contactor- 8KW ---- etc., complete with all leadEach14892.7814892.781.0FalseNoneNoneFalseNoneFalse14892.780
3046676102979None5.15.17Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Therm IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE320-400Amps 50kA ---- etc., complete with all leadNo37307.5337307.532.0FalseNoneNoneFalseNoneFalse74615.060
17103318720000NoneNoneBuildingsMGPLS WORKS10758036.4
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3046677102980NoneLeast Quotation RateOxygen Manifold: Main 10+10 Cylinder Oxygen Manifold Should be suitable to withstand a pressure of 140 Kg/Cm2and above along with high pressure copper annealed tail pipes with end Brass adapter suitable for Oxygen Cylinders and manifold. Top frame comprising of high pressure copper pipes of size 12mm I.D x 1.5mm wall thick, with high pressure brass fittings made of high tensile brass and connections through non-return values; high pressure copper tail pipes, made of high pressure copper pipe of size 7mm I.D x 1.5mm wall thick. The design of middle and bottom frames Should be provided to fit both round and flat bottom cylinders safely. The manifold should be tested (hydraulically) at 3500 pig. ---- etc., complete with all leadSet128915.0128915.01.0FalseNoneNoneFalseNoneFalse128915.00
3046678102980NoneLeast Quotation RateMicro process based Automatic High flow upto 2100 ltrs/min Oxygen Control Panel. “3 SOURCE FULLY AUTOMATIC OXYGEN CONTROL PANEL" *Working Pressure from the oxygen concentrator plant4.1 kg/cm2 (Future Provision) *Working Pressure from fully automatic control panel-4.1 kg/cm2 *Working Pressure from Emergency manifold system-4.1 kg/cm2 *Changeover unit of all 3 sources Should be at the pressure from oxygen concentrator plant Below 4.1kg/cm2 *Changeover unit of all 3 sources Should be at the pressure from main Manifold system Below 4.1kg/cm2 *Changeover unit of all 3 sources Should be at the pressure from Emergency manifold system Below 4.1kg/cm2 The Control pannel shall be of fully integrated type with all saftety futures inbuilt for high pressure and high flow upto 2200 ltrs / min Oxygen system. * All the electrical circuits Should be operated at 12 volts & 24 volts with provision of inbuilt power conversion equipment.. The Pannel shall have the necessary instruments, gauges, LED Indicators etc complete with Separate indicators for from separate 3 sources. Pressure from oxygen concentrator plant Green signal for Normal pressure & Red signal for Low pressure. Pressure for manifold system - Green signal for Normal Pressure & Red signal for low pressure. Left bank Green signal for Normal Pressure & Red for Low pressure. In Right bank Green signal for Normal Pressure & Red for Low pressure. In Emergency manifold Green signal for Normal Pressure & Red for Low pressure. Main Line Green signal for Normal Pressure & Red for Low pressure. ---- etc., complete with all leadSet217120.0217120.01.0FalseNoneNoneFalseNoneFalse217120.00
3046679102980NoneLeast Quotation RateOxygen Manifold System : Emergency 2+2 Cylinder Oxygen Manifold Should be suitable be withstand a pressure of 140 Kg/Cm2and above, along with high pressure copper annealed tail pipes with end Brass adapter suitable for Oxygen Cylinders and manifold.Top frame comprising of high pressure copper pipes of size 12mmI.D x 1.5mm wall thick, with high pressure brass fittings made of high tensile brass and connections through non-return values; high pressure copper tail pipes, made of high pressure copper pipe of size 7mm I.D x 1.5mm wall thick and a single state high pressure high flow regulator connected to a high pressure brass block. The design of middle and bottom frames should be provided to fit both round and flat bottom cylinders safely. The manifold should be tested (hydraulically) at 3500 psig and necessary test certificates should accompany along with the supply. Semi automatic control panels designed for various control functions required during supply of oxygen through the manifold unit. Enclosed in a metal cabinet. This semi automatic control panel is highly efficient in triggering the signal for the Reserve system to go operational in case primary and secondary system fails in emergency. This panel is normally connected in a permanent mode and change over is semi automatic. Some of the features of this pannels are as follows : *Control panel shall be made of M.S.duly powder coated. *Easy maintenance. *Highly reliable. *Designed for safety and continuity of flow supply at a constant pressure * Pressure gauge facility to indicate the gas pressure of each header and pipe line distribution pressure * Capable to provide a distribution flow rate in excess of 1500LPM. * Should have Incorporation of safety features in case pressure exceeds 100Psi. ---- etc., complete with all leadSet94990.094990.01.0FalseNoneNoneFalseNoneFalse94990.00
3046680102980NoneLeast Quotation RateNitrous Oxide Main Manifold System Supply, Installation, Testing and commissioning of 2 cylinder (1 + 1) Nitrous Oxide manifold supply with all necessary controls and safety fittings. Make of AKTIV or Equilaent Make complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. Semi Automatic Nitrous Oxide Main Manifold Control Panel Supply, Installation, Testing and commissioning of 500 lpm deliver capacity manifold control panel, control panel should have all necessary controls and safety fittings. with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. Nitrous Oxide System ---- etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all leadSet88500.088500.01.0FalseNoneNoneFalseNoneFalse88500.00
3046681102980NoneLeast Quotation RateNitrous Oxide Emergency Manifold System Supply, Installation, Testing and commissioning of 1 cylinders Nitrous Oxide manifold supply with all necessary controls and safety fittings and 0 To 10 Kg/cm2 High Presuure Regulator complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all leadSet47200.047200.01.0FalseNoneNoneFalseNoneFalse47200.00
3046682102980NoneLeast Quotation RateCompressed Air System: System For Medical use Type : Reciprocating, Air cooled oil grease free Capacity of Piston Displacement : 22.93 cfm 649 Lpm, Drive : Belt driven , No. of Air Compressors : 2 Nos. (1W + 1S by) ,Motor Capacity : 5 HP as required , Receiver Capacity : 1000 liters water capacity Air reciever , Receiver type : Vertical type with inlet, outlet & drain provisions ---- etc., complete with all leadSet800630.0800630.01.0FalseNoneNoneFalseNoneFalse800630.00
3046683102980NoneLeast Quotation RateDuplex Medical Air Dryer System ( Breathing Air System) 40 CFM *Air Dryer Min Working Pressure should be 4 bar, Rated Inlet Pressure should be 7 bar Max Working Pressure should be 16 bar , Supply Voltage Should be 100-240 VAC, 50/60 Hz, 1 Ph , Rated Inlet temperature should be 38 deg C, Dryer capable to give should be 40 PDP, Purge Loss 15% , Air quality As per NFPA 99 Dual System Three stage filter (Dessicated drier) CO & Dew point level as per NFPA 99 Bacterial Penetration 0.00001% Failure Indication, Purge Saving control - Manual,No refrigerant used,Energy saving - Dew point based dryer cycling. ---- etc., complete with all leadNos88205.088205.01.0FalseNoneNoneFalseNoneFalse88205.00
3046684102980NoneLeast Quotation RateCOMPRESSED AIR BREATHING FILTERATION SYSTEM-3 STAGE The filters Shouldhave maximum contaminant removal efficiency with minimum pressure drop. The filtration system should conform to breathing air filtration as per ISO 8573 Ch - I Standard. Total 3-stages of filters Shouldbe used as mentioned below: Stage 1: Oil aerosol contents removal up to 0.5 mg/cum Stage 2: Oil aerosol contents removal up to 0.01 mg/cum. Stage 3: Oil content removal up to 0.003 mg/cum along with removal of oil vapor and hydrocarbon odor as per ISO 8573 Ch-I Standard. ---- etc., complete with all leadSet70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3046685102980NoneLeast Quotation RateAir Cooler : Supply, Installation, Testing and Commissioning of 80 CFM Air cooler system, with 3 phase fan (High RPM Fan) suitable for 415 V, 3Phs 50 Hz ---- etc., complete with all leadNo70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3046686102980NoneLeast Quotation RateVACCUM SUPPLY SYSTEM COMPLETE IN ALL RESPECT (with receiver tank): The pump installation shall be duplex system consisting of two (1W+1S BY) Identical Rotary Vane Pumps each of which shall be capable of independently producing designed systems flow rate. The pump shall be clearly marked with its performance, both its free air displacement and its volumetric throughput. Each pump should have capacity of minimum 3276 LPM (200m3/h) i.e., 117 CFM. Pump should be capable of providing a vacuum of not less than 650 mm Hg (87 kPa). The driving motor shall directly drive the pump unit and it shall be manufactured in accordance with HTM 2022/HTM 02-01 / conforms to IEC Standards. Recommendations suitable for 415 voltes, 3 phase, 50 Hz power supply.Each pump shall have a built in non-return valve and pressure switch such that inadvertent reversal of the motor Should not pressurize the Reservoir or the distribution system. Pump should be of reputed make as per international standards. The control panel shall consist of three separate Compartments, two compartments shall hold the motor starters, MCBS ammeters, and hour’s run-meters, for each pump. The remaining compartment shall house the vacuum switches, status monitoring equipment, delay timer and necessary interlock, selector switch with automatic change over, etc., complete with internal wiring using copper conductors. Control Panel system should be front operable. The system should include vacuum storage reservoir tank, Rated for full vacuum services with the storage capacity of approx 1500 Liter or as per standard recommendation. It should be equipped with an vacuum gauge and provision for manual draining by pass valve. The inside of the tank should be coated with a two-component coating to provide a hard, durable lining for rust protection. *The System should provide audible and visual local and remote alarm indications for the compressor temperature malfunction and reserve compressor in use. All control and alarm functions should remain energized while any compressor remains electrically on-line. * The System should provide manual reset for thermal malfunction shutdown. *The lag Pumps should be able to start automatically if the lead compressor fails to operate. ---- etc., complete with all leadSet949900.0949900.01.0FalseNoneNoneFalseNoneFalse949900.00
3046687102980NoneLeast Quotation RateVACUUM BACTERIAL FILTERATION: Suitable Medical Vacuum filters are used for removal of bacteria & other contamination from the suction side of vacuum pumps, preventing infection of pump and the atmosphere. These elements shall be of pleated construction giving a high surface area and long operational life. The efficiency to exceed the 0.005% penetration specified in HTM2022 for infectious disease unit.- i.e. complete bacterial removal. Elements shall be fitted in an aluminum housing suitable for various capacities. These are to be internally protected against corrosion by an alocrom treatment. The inner & outer surfaces of the housing are epoxy coated. Complete assembly shall be fitted with a sterilisable drain flask with isolation valve for removal of liquid if any. Differential pressure indicators are to be provided to monitor the status of element. Basics Specifications are as given below, FAC AT Atmospheric : 1850 LPM Size : G 1 1/2 Bacterial Removal : 0.0001% penetration when tested to BS: 3928 ---- etc., complete with all leadSet165200.0165200.01.0FalseNoneNoneFalseNoneFalse165200.00
3046688102980NoneLeast Quotation RateCopper Fittings: Supply, Installation, Testing and Commissioning : All copper pipes should be Solid drawn, seamless, deoxidized, non arsenical, half hard, tempered and degreased materials conforming to BS:EN :13348:2001 + A1:2005. Fittings should be made of copper and suitable for a stem of working pressure of 17 bar and Should confirm to BS 864 with specially made for brazed socket type connections. Copper Pipe 42mm. ODx1.2 mm.thick. ---- etc., complete with all leadm3608.443608.4490.0FalseNoneNoneFalseNoneFalse324759.60
3046689102980NoneLeast Quotation RateCopper Fittings: Supply, Installation, Testing and Commissioning : All copper pipes should be Solid drawn, seamless, deoxidized, non arsenical, half hard, tempered and degreased materials conforming to BS:EN :13348:2001 + A1:2005. Fittings should be made of copper and suitable for a stem of working pressure of 17 bar and Should confirm to BS 864 with specially made for brazed socket type connections. Copper Pipe 35mm. ODx1.2 mm.thick. ---- etc., complete with all leadm2570.042570.04180.0FalseNoneNoneFalseNoneFalse462607.20
3046690102980NoneLeast Quotation RateCopper Fittings: Supply, Installation, Testing and Commissioning : All copper pipes should be Solid drawn, seamless, deoxidized, non arsenical, half hard, tempered and degreased materials conforming to BS:EN :13348:2001 + A1:2005. Fittings should be made of copper and suitable for a stem of working pressure of 17 bar and Should confirm to BS 864 with specially made for brazed socket type connections. Copper Pipe 28mm. ODx0.9 mm.thick. ---- etc., complete with all leadm1492.71492.7350.0FalseNoneNoneFalseNoneFalse522445.00
3046691102980NoneLeast Quotation RateCopper Fittings: Supply, Installation, Testing and Commissioning : All copper pipes should be Solid drawn, seamless, deoxidized, non arsenical, half hard, tempered and degreased materials conforming to BS:EN :13348:2001 + A1:2005. Fittings should be made of copper and suitable for a stem of working pressure of 17 bar and Should confirm to BS 864 with specially made for brazed socket type connections. Copper Pipe 22mm. ODx0.9 mm.thick. ---- etc., complete with all leadm1156.41156.4450.0FalseNoneNoneFalseNoneFalse520380.00
3046692102980NoneLeast Quotation RateCopper Fittings: Supply, Installation, Testing and Commissioning : All copper pipes should be Solid drawn, seamless, deoxidized, non arsenical, half hard, tempered and degreased materials conforming to BS:EN :13348:2001 + A1:2005. Fittings should be made of copper and suitable for a stem of working pressure of 17 bar and Should confirm to BS 864 with specially made for brazed socket type connections. Copper Pipe 15mm. ODx0.9 mm.thick. ---- etc., complete with all leadm949.9949.9950.0FalseNoneNoneFalseNoneFalse902405.00
3046693102980NoneLeast Quotation RateCopper Fittings: Supply, Installation, Testing and Commissioning : All copper pipes should be Solid drawn, seamless, deoxidized, non arsenical, half hard, tempered and degreased materials conforming to BS:EN :13348:2001 + A1:2005. Fittings should be made of copper and suitable for a stem of working pressure of 17 bar and Should confirm to BS 864 with specially made for brazed socket type connections. Copper Pipe 12mm. ODx0.7 mm.thick. ---- etc., complete with all leadm651.36651.36420.0FalseNoneNoneFalseNoneFalse273571.20
3046694102980NoneLeast Quotation RateOxygen Terminals - drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes) ---- etc., complete with all leadNos3392.53392.5120.0FalseNoneNoneFalseNoneFalse407100.00
3046695102980NoneLeast Quotation RateVacuum Terminal - drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes) ---- etc., complete with all leadNos3392.53392.570.0FalseNoneNoneFalseNoneFalse237475.00
3046696102980NoneLeast Quotation RateCompressed Air Terminals 4 Bar - drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes) ---- etc., complete with all leadNos3392.53392.570.0FalseNoneNoneFalseNoneFalse237475.00
3046697102980NoneLeast Quotation RateCompressed Air Terminals 7 Bar- drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes) ---- etc., complete with all leadNos3392.53392.57.0FalseNoneNoneFalseNoneFalse23747.50
3046698102980NoneLeast Quotation RateNitous Oxide Terminals - drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes) ---- etc., complete with all leadNos3392.53392.57.0FalseNoneNoneFalseNoneFalse23747.50
3046699102980NoneLeast Quotation RateACCESSORIES ALONG WITH CALIBRATION CERTIFICATES. Oxygen Flow meter with Humidifier Bottle: *Flow meter should be Backpressure Compensated. *Flow meter should be accurate gas flow measurement and control within a range of 0-15 liters per minute. *It should meet strict precision and durability standards. * Flow meter body should be made of brass material. * Flow tube and shroud components should be made of clear, impact resistant polycarbonate. * The humidifier bottle should be unbreakable polycarbonate material and autoclavable at 134 degrees centigrade. * The humidifier should have built in safety valve. ---- etc., complete with all leadNos2849.72849.770.0FalseNoneNoneFalseNoneFalse199479.00
3046700102980NoneLeast Quotation RateSingle piece wall mounted suction collection & regulation unit. With jar capacity of 600ml each shall be provided at each of the bed side. Jars are should be made of autoclavable materials. The units shall be clamped to the wall using suitable clamps. ---- etc., complete with all leadNos3528.23528.267.0FalseNoneNoneFalseNoneFalse236389.40
3046701102980NoneLeast Quotation RateTheatre Vacuum Unit: * The unit should comprise of two reusable 2000 ml shatter resistant bottle, each made up of poly carbonate material and fully auto cleavable at 134 degree centigrade.  * Should have a vacuum regulator with instant ON / OFF switch a three way selector switch with an option to operate either. - Left, Right or Both All the above items Should be mounted on a Trolley having a free moving castor wheels. ---- etc., complete with all leadNos14750.014750.03.0FalseNoneNoneFalseNoneFalse44250.00
3046702102980NoneLeast Quotation RateISOLATION VALVES: Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction Isolation Valves 42 mm ---- etc., complete with all leadNos8142.08142.02.0FalseNoneNoneFalseNoneFalse16284.00
3046703102980NoneLeast Quotation RateISOLATION VALVES: Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction Isolation Valves 35 mm ---- etc., complete with all leadNos5428.05428.06.0FalseNoneNoneFalseNoneFalse32568.00
3046704102980NoneLeast Quotation RateISOLATION VALVES: Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction Isolation Valves 28 mm ---- etc., complete with all leadNos4071.04071.010.0FalseNoneNoneFalseNoneFalse40710.00
3046705102980NoneLeast Quotation RateISOLATION VALVES: Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction Isolation Valves 22 mm ---- etc., complete with all leadNos3392.53392.515.0FalseNoneNoneFalseNoneFalse50887.50
3046706102980NoneLeast Quotation RateISOLATION VALVES: Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction Isolation Valves 15 mm ---- etc., complete with all leadNos2714.02714.053.0FalseNoneNoneFalseNoneFalse143842.00
3046707102980NoneLeast Quotation RateZonal Valve box three Gas services An Zonal area valve box should have bellow spec. * Wall mounted M.S. box with powder coated & lockable, * front glass mounting easily visible & using imported brass body quarter turn ball valves using for opening & closing position. The valve box door cannot be close during valve close position. ---- etc., complete with all leadNos18319.518319.55.0FalseNoneNoneFalseNoneFalse91597.50
3046708102980NoneLeast Quotation RateZonal Valve box five Gas services An Zonal area valve box should have bellow spec. * Wall mounted M.S. box with powder coated & lockable, * front glass mounting easily visible & using imported brass body quarter turn ball valves using for opening & closing position. The valve box door cannot be close during valve close position. ---- etc., complete with all leadNos23364.023364.04.0FalseNoneNoneFalseNoneFalse93456.00
3046709102980NoneLeast Quotation RateDigital Area Alarm for Three Gas Systems: Micro processor controlled Area Gas alarm panel five Lines, Should audio- visual alarms for each gas used on the floor and come fitted with test and mute button. Running on electricity 220V, these units are suggested to be fitted on each floor as well as areas of heavy usage. It should be fitted with a digital pressure gauge. It indicates low, medium & high pressure sensors. ---- etc., complete with all leadNos34220.034220.05.0FalseNoneNoneFalseNoneFalse171100.00
3046710102980NoneLeast Quotation RateDigital Area Alarm for Five Gas Systems: Micro processor controlled Area Gas alarm panel five Lines, Should audio- visual alarms for each gas used on the floor and come fitted with test and mute button. Running on electricity 220V, these units are suggested to be fitted on each floor as well as areas of heavy usage. It should be fitted with a digital pressure gauge. It indicates low, medium & high pressure sensors. ---- etc., complete with all leadNos41300.041300.04.0FalseNoneNoneFalseNoneFalse165200.00
3046711102980NoneLeast Quotation RateBed Headed Panel and Railing. 1.5M Double railing Bed headed panels should have below Specifications. Accessories 1. IV Stand extendable type with aluminium slider. 2. Monitor stand wall panel mounted. 3. Ward vaccum unit slider. 4. 3/6W LED light fixture. 5. Twpo duplex 230 V,6/16 Amp 6 nos of 6 amps sockets with control switches Electrical Sockets. Including Medical Gas Terminal Units as follows.  2.1 Two oxygen outlet. 2.2  One Vacuum outlet. 2.3 One compressed Air outlet 4 Bar. ---- etc., complete with all leadNos31860.031860.045.0FalseNoneNoneFalseNoneFalse1433700.00
3046712102980NoneLeast Quotation RateSurgeon Single Arm Pendant: The material of the Pendent should be Single-armed rotary ceiling mounted surgical Pendent High-strength aluminum alloy. Extension arm 700mm. Loading capacity: 70-150kg. Level degrees rotation:lesserthan 340n.w.:158kg. Should be including for Gas outlets Oxygen 02 nos, Vaccum 01 nos, Air 4 Bar 01 nos, Air 7 Bar 01 nos, Nitrous Oxide01 nos, Power socket 08 nos, Grounding terminal 01 nos, Platform 03 nos, IV pole 01 nos, Drawer 01 nos. ---- etc., complete with all leadNos230100.0230100.03.0FalseNoneNoneFalseNoneFalse690300.00
3046713102980NoneLeast Quotation RateAnaesthesia Single Arm Pendant: The material of the Pendent should be Single-armed rotary ceiling mounted surgical Pendent High-strength aluminum alloy. Extension arm 700mm.Loading capacity: 70-150kg.Level degrees rotation: lesserthan 340n.w.:158kg. Should be including for Gas outlets Oxygen 02 nos, Vaccum 01 nos,Air 4 Bar 01 nos,Air 7 Bar 01 nos, Nitrous Oxide01 nos,Power socket 08 nos,Grounding terminal 01 nos,Platform 03 nos, IV pole 01 nos,Drawer 01 nos. ---- etc., complete with all leadNos230100.0230100.03.0FalseNoneNoneFalseNoneFalse690300.00
17103318720000NoneNoneBuildingsFIRE FIGHTING WORKS10276097.78
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3046714102981NonePWD SR 2023-24 V-6 Page No 88 Item No 15.83.1Supplying, Installing, testing and commissioning approved make Centrifugal pump end suction type couple to Electric motor of suitable Hp, fitted on a common base frame and rated for Fire duty. The quoted price shall aslso include 2 nos. Pressure guages fitted on suction & delivery side of the pump. The pumps shall run on 400/440V, 3 ph, 50Hz electric supply. Duty of pums: 1620 Lpm @ 70.0m Head. Control panel shall be per specification stated in Item No.87. including cost of materials, labour, usage charges of machinery complete as per specifications. (Cost of control pannel is not included) ---- etc., complete with all leadNo291165.0291165.01.0FalseNoneNoneFalseNoneFalse291165.00
3046715102981NonePWD SR 2023-24 V-6 Page No 88 Item No 15.84.2Supplying, Installing testing and commissioning of fire hydrant multi stage pump capable of delivering 1620 Lpm@ 70.0m head coupled to water coiled diesel enginer of adequate. HP It shall be fitted with a radiator on a common base frame with complete ancillary units such as coiling sytem, non return vialve, Y strainer, fuel tank of adequante capactiy, Pressure guage, pressure switch etc. complete Control panel shall be per specification stated in Item No.87. including cost of materials, labour, usage charges of machinery complete as per specifications. (Cost of control pannel is not included) ---- etc., complete with all leadNo607110.0607110.01.0FalseNoneNoneFalseNoneFalse607110.00
3046716102981NonePWD SR 2023-24 V-6 Page No 88 Item No 15.85Supplying, Installing testing & commissioning electrically driven jockey pump of capacity 180.0 Lmpm at 75.0m head with all the necessary accessories viz. Pressure guages etc. operating on 3Ph 50Hz, 400/440V AC supply including foundation bolt etc. complete. Control panel shall be as per item No.87, including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all leadNo105315.0105315.01.0FalseNoneNoneFalseNoneFalse105315.00
3046717102981NonePWD SR 2023-24 V-6 Page No 97 Item No 15.139Supplying Installing testing and commissiong COMMON Control panel for fire fighting system consiting of electrical motor driven 60HP Main fire pump, Diesel engine driven pump 60 HP Sprinkler pump 50HP & Jockey pump 25HP ---- etc., complete with all leadUnit344442.0344442.01.0FalseNoneNoneFalseNoneFalse344442.00
3046718102981NonePWD SR 2023-24 V-6 Page No 86 Item No 15.77Supplying, Installing testing & commissioning approved make Centrifugal pump end suction type coupled to Electric motor of suitable HP, fitted on a commonbase frame and rated for Fire duty. The quated price shall aslo include 2 Nos. Pressure guages fitted on suction & delivery sides of the pump. The pumps shall run on 400/440V 3 ph. 50 Hz electric supply. Duty of pumps: 900 Lpm @ 35.0m Head. Control panel shall be as specified in item no, 87, including cost of materials, labour, usage charges of machinery complete as per specifications.(FOR WATER CURTAIN) ---- etc., complete with all leadNo111510.0111510.01.0FalseNoneNoneFalseNoneFalse111510.00
3046719102981NonePWD SR 2023-24 V-6 Page No 94 Item No 15.127.2Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13039 of following sizes as required 150mm dia ---- etc., complete with all leadNos15487.515487.59.0FalseNoneNoneFalseNoneFalse139387.50
3046720102981NonePWD SR 2023-24 V-6 Page No 94 Item No 15.127.3Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13039 of following sizes as required 100mm dia ---- etc., complete with all leadNos11151.011151.05.0FalseNoneNoneFalseNoneFalse55755.00
3046721102981NonePWD SR 2023-24 V-6 Page No 94 Item No 15.127.4Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13039 of following sizes as required 80mm dia ---- etc., complete with all leadNos8673.08673.02.0FalseNoneNoneFalseNoneFalse17346.00
3046722102981NonePWD SR 2023-24 V-6 Page No 95 Item No 15.128.2Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :150 mm dia ---- etc., complete with all leadNos14248.514248.56.0FalseNoneNoneFalseNoneFalse85491.00
3046723102981NonePWD SR 2023-24 V-6 Page No 95 Item No 15.128.3Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100 mm dia ---- etc., complete with all leadNos8821.688821.682.0FalseNoneNoneFalseNoneFalse17643.360
3046724102981NonePWD SR 2023-24 V-6 Page No 95 Item No 15.128.4Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :80 mm dia ---- etc., complete with all leadNos6814.56814.52.0FalseNoneNoneFalseNoneFalse13629.00
3046725102981NonePWD SR 2023-24 V-6 Page No 95 Item No 15.129.1Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.200mm dia ---- etc., complete with all leadNo30355.530355.53.0FalseNoneNoneFalseNoneFalse91066.50
3046726102981NonePWD SR 2023-24 V-6 Page No 95 Item No 15.128.3Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100 mm dia ---- etc., complete with all leadNo15351.2115351.211.0FalseNoneNoneFalseNoneFalse15351.210
3046727102981NonePWD SR 2023-24 V-6 Page No 96 Item No 15.136Supplying and fixing air vessel made of 250 mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. ---- etc., complete with all leadNo37170.037170.01.0FalseNoneNoneFalseNoneFalse37170.00
3046728102981NonePWD SR 2023-24 V-6 Page No 96 Item No 15.132Pressure guage of 150 mm dia including Isolation Valve and forged siphon Tube including with all accssories as per IS:Spec. ---- etc., complete with all leadNo3593.13593.13.0FalseNoneNoneFalseNoneFalse10779.30
3046729102981NonePWD SR 2023-24 V-6 Page No 95 Item No 15.131Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. ---- etc., complete with all leadNos2416.052416.056.0FalseNoneNoneFalseNoneFalse14496.30
3046730102981NonePWD SR 2023-24 VOL-2 Page No 82 Item No 11.16.2Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all leadKg182.13182.13300.0FalseNoneNoneFalseNoneFalse54639.00
3046731102981NoneBSR 21-22 Page No Item No 32.14FIREFIGHTING ELECTRICALSupply of the Following XLPE armoured cable 1100 V Grade with ISI mark stranded / solid, aluminimum conductor complete with crimping type Lugs and Glands etc completed. 3.5 Core 95.00 Sq.mm.Main Panel Electrical Pump ---- etc., complete with all leadKm636895.56636895.560.08FalseNoneNoneFalseNoneFalse50951.64480
3046732102981NoneBSR 21-22 Page No Item No 32.14FIREFIGHTING ELECTRICALSupply of the Following XLPE armoured cable 1100 V Grade with ISI mark stranded / solid, aluminimum conductor complete with crimping type Lugs and Glands etc completed. 3.5 Core 95.00 Sq.mm.Main Panel Electrical Pump ---- etc., complete with all leadKm636895.56636895.560.1FalseNoneNoneFalseNoneFalse63689.5560
3046733102981None21-22 Page No Item No 32.05FIREFIGHTING ELECTRICALSupply of the Following XLPE armoured cable 1100 V Grade with ISI mark stranded / solid, aluminimum conductor complete with crimping type Lugs and Glands etc completed. 4.0 Core 16.00 Sq.mm.Main Panel to Jockey ---- etc., complete with all leadKm227284.63227284.630.2FalseNoneNoneFalseNoneFalse45456.9260
3046734102981NoneLeast Quotation Rate12 Core x 2.5Sqmm For Main Panel to DG ---- etc., complete with all leadm684.4684.450.0FalseNoneNoneFalseNoneFalse34220.00
3046735102981NoneCPWD SR 21-22 Page No 3 Item No 1.17.33 Core x 1.5Sqmm for Pressure Switch ---- etc., complete with all leadm117.7117.750.0FalseNoneNoneFalseNoneFalse5885.00
3046736102981NonePWD SR 2023-24 V-6 Page No 38 Item No 9.4.6Supplying, installation, testing & commissioning of 12V ..AH batteries in poly propylene container for D.G. sets. Low maintenance batteries, plate type. (150 AH capacity) ---- etc., complete with all leadNos34923.6934923.691.0FalseNoneNoneFalseNoneFalse34923.690
3046737102981NoneCPWD SR 21-22 Page No 18 Item No 4.1.4Supplying and installing following size of perforated painted with powder cating m.s. cable trays with perforation not more than 17.5% in convenient sections, joined with connectors, suspended from the ceiling with m.s. suspenders including bolts & nuts, painting suspendrrs etc as required. ---- etc., complete with all leadm916.86916.86100.0FalseNoneNoneFalseNoneFalse91686.00
3046738102981NonePWD SR 2023-24 V-6 Page No 54 Item No 12.58.2GI/Copper strips for grounding connections, using necessary fixing materials as required. (25 x 3 mm GI strip) ---- etc., complete with all leadm101.59101.59150.0FalseNoneNoneFalseNoneFalse15238.50
3046739102981NonePWD SR 2023-24 V-6 Page No 89 Item No 15.86Supplying Installing, testing and commissioning of Gun metal AIR RELEASE VALVE SIZE OF 25mm dia including cost of materials, labour, usage charges of machinery complete as per specifications. complete ---- etc., complete with all leadEach1858.51858.51.0FalseNoneNoneFalseNoneFalse1858.50
3046740102981NonePWD SR 2023-24 V-6 Page No 94 Item No 15.125SITC of Gun metal BALL VALVE SIZE OF 25mm dia ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work ---- etc., complete with all leadNos1486.81486.88.0FalseNoneNoneFalseNoneFalse11894.40
3046741102981NonePWD SR 2023-24 V-6 Page No 94 Item No 15.126SITC of Gun metal BALL VALVE SIZE OF 19/20 mm dia ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work ---- etc., complete with all leadNos1177.051177.058.0FalseNoneNoneFalseNoneFalse9416.40
3046742102981NonePWD SR 2023-24 V-6 Page No 91 Item No 19.7.3Fire Hydrant & Sprinkler System Supply: Installation testing and commissioning of approved make heavy quantity (Class 'C') confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. 150 mm dia ---- etc., complete with all leadm4832.14832.1400.0FalseNoneNoneFalseNoneFalse1932840.00
3046743102981NonePWD SR 2023-24 V-6 Page No 91 Item No 19.7.4Installation testing and commissioning of approved make heavy quantity (Class 'C') confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. 100 mm dia ---- etc., complete with all leadm3531.153531.15200.0FalseNoneNoneFalseNoneFalse706230.00
3046744102981NonePWD SR 2023-24 V-6 Page No 91 Item No 19.7.5Installation testing and commissioning of approved make heavy quantity (Class 'C') confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. 80 mm dia ---- etc., complete with all leadm2849.72849.7120.0FalseNoneNoneFalseNoneFalse341964.00
3046745102981NonePWD SR 2023-24 V-6 Page No 91 Item No 19.7.6Installation testing and commissioning of approved make heavy quantity (Class 'C') confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. 65 mm dia ---- etc., complete with all leadm2106.32106.3100.0FalseNoneNoneFalseNoneFalse210630.00
3046746102981NonePWD SR 2023-24 V-6 Page No 91 Item No 19.7.7Installation testing and commissioning of approved make heavy quantity (Class 'C') confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. 50 mm dia ---- etc., complete with all leadm1610.71610.7120.0FalseNoneNoneFalseNoneFalse193284.00
3046747102981NonePWD SR 2023-24 V-6 Page No 91 Item No 19.7.8Installation testing and commissioning of approved make heavy quantity (Class 'C') confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. 40 mm dia ---- etc., complete with all leadm1300.951300.95135.0FalseNoneNoneFalseNoneFalse175628.250
3046748102981NonePWD SR 2023-24 V-6 Page No 91 Item No 19.7.9Installation testing and commissioning of approved make heavy quantity (Class 'C') confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. 32 mm dia ---- etc., complete with all leadm991.2991.2100.0FalseNoneNoneFalseNoneFalse99120.00
3046749102981NonePWD SR 2023-24 V-6 Page No 91 Item No 19.7.10Installation testing and commissioning of approved make heavy quantity (Class 'C') confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. 25 mm dia ---- etc., complete with all leadm867.3867.3220.0FalseNoneNoneFalseNoneFalse190806.00
3046750102981NonePWD SR 2023-24 V-6 Page No 91 Item No 15.98.2Wraping and Galing of U/G pipe line work includes one coat of anti corrossion paint (Black) and two coats of Bituminous cloth. including cost of materials, labour, usage charges of machinery complete as per specifications. - 150 mm dia ---- etc., complete with all leadm495.6495.6400.0FalseNoneNoneFalseNoneFalse198240.00
3046751102981NonePWD SR 2023-24 V-6 Page No 91 Item No 15.98.3Wraping and Galing of U/G pipe line work includes one coat of anti corrossion paint (Black) and two coats of Bituminous cloth. including cost of materials, labour, usage charges of machinery complete as per specifications. - 100 mm dia ---- etc., complete with all leadm309.75309.75100.0FalseNoneNoneFalseNoneFalse30975.00
3046752102981NonePWD SR 2023-24 V-6 Page No 94 Item No 15.127.3Supplying, installing , testing and commissioning approved make CI butterfly valves of 100mm diameter confirming to IS 13039 with necessary nuts & bolts etc., complete ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work ---- etc., complete with all leadNos11151.011151.04.0FalseNoneNoneFalseNoneFalse44604.00
3046753102981NonePWD SR 2023-24 V-6 Page No 94 Item No 15.127.6Supplying, installing , testing and commissioning approved make CI butterfly valves of 50mm diameter confirming to IS 13039 with necessary nuts & bolts etc., complete ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work ---- etc., complete with all leadNos5575.55575.54.0FalseNoneNoneFalseNoneFalse22302.00
3046754102981NoneCPWD -21-22 Page No Item No 18.23.2Providing & fixing Flow Switch in following sizes M.S. pipe including connnection etc as required.150mm dia ---- etc., complete with all leadEach11177.0111177.014.0FalseNoneNoneFalseNoneFalse44708.040
3046755102981NonePWD SR 2023-24 V-6 Page No 90 Item No 15.96.2Providing, fixing, testing & commissioning ofinstallation control valve of cast iron body,brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm andhydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required : 150mm dia ---- etc., complete with all leadEach86730.086730.01.0FalseNoneNoneFalseNoneFalse86730.00
3046756102981NonePWD SR 2023-24 V-6 Page No 94 Item No 15.123Supplying Installing, testing and commissioning of 150mm dia 4 way Fire brigade inlet connection with Non retrn valve of 4 nos. 63 mm dia. including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all leadNo47082.047082.01.0FalseNoneNoneFalseNoneFalse47082.00
3046757102981NonePWD SR 2023-24 V-6 Page No 94 Item No 15.124Supplying Installing, testing and commissioning of 100mm dia 2 way Fire brigade inlet connection of 2 nos. 63 mm dia. including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all leadNo40887.040887.01.0FalseNoneNoneFalseNoneFalse40887.00
3046758102981NonePWD SR 2023-24 V-6 Page No 89 Item No 15.86FIRE HYDRANT SYSTEM Supplying Installing, testing and commissioning of 63mm dia single headed Gun mental Hydrant Valve with flanged inlet, stop valve,spindle and cast iron hand wheel. It has a female instantaneous outlet with Blank Cap and is Hydrostatically tested to 21 Kgf/cm2 pressure having a flow rate of 900 LPM at 7 Kgf/cm 2 of pressure with blank cap and wheel as per IS 5290 etc. complete including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all leadNo13009.513009.58.0FalseNoneNoneFalseNoneFalse104076.00
3046759102981NonePWD SR 2023-24 V-6 Page No 89 Item No 15.88Supplying Installing, testing and commissioning of Reinforced Rubber Lined 2nos .RRL Fire hose of 63mm dia 15m length as per IS 8423 binded with one set of male and Female lnstantainious Gun metal coupling as per IS 903 complete including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all leadEach6195.06195.016.0FalseNoneNoneFalseNoneFalse99120.00
3046760102981NonePWD SR 2023-24 V-6 Page No 89 Item No 15.87Supplying Installing, testing and commissioning of Gun metal Branch pipe size of 63mm dia x19mm dia as per IS 903 complete including cost of materials, labour,usage charges of machinery complete as per specifications. ---- etc., complete with all leadEach5575.55575.516.0FalseNoneNoneFalseNoneFalse89208.00
3046761102981NonePWD SR 2023-24 V-6 Page No 89 Item No 15.89Supplying Installing, testing and commissioning of Hose cabinet made out of 18 gauge M.S.sheet with double glass door with lacing arrangement and painted with two coats of Fire red Enamel paint at outer ise of the Box and two coats of white enamel paint at inner side of the box is to accomodated 2 Nos. of Fire hose box size 20"x24"x10" complete including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all leadEach8053.58053.58.0FalseNoneNoneFalseNoneFalse64428.00
3046762102981NonePWD SR 2023-24 V-6 Page No 89 Item No 15.9Supplying Installing, testing and commissioning of Hose reel cabin ---- etc., complete with all leadEach6318.96318.98.0FalseNoneNoneFalseNoneFalse50551.20
3046763102981NonePWD SR 2023-24 V-6 Page No 89 Item No 15.91Supplying Installing, of M.S. Pressed reel of 600mm dia swinging type motion which allows a 180 Degree swing and conforms to IS:884/85 or Aluminium fitting Single Piece Compact Type. including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all leadEach6442.86442.84.0FalseNoneNoneFalseNoneFalse25771.20
3046764102981NonePWD SR 2023-24 V-6 Page No 89 Item No 15.86Supplying Installing, testing and commissioning of Gun metal AIR RELEASE VALVE SIZE OF 25mm dia including cost of materials, labour, usage charges of machinery complete as per specifications. complete ---- etc., complete with all leadEach1858.51858.52.0FalseNoneNoneFalseNoneFalse3717.00
3046765102981NonePWD SR 2023-24 V-6 Page No 94 Item No 15.125SITC of Gun metal BALL VALVE SIZE OF 25mm dia ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work ---- etc., complete with all leadNos1486.81486.84.0FalseNoneNoneFalseNoneFalse5947.20
3046766102981NonePWD SR 2023-24 V-6 Page No 123 Item No 13.37Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. ---- etc., complete with all leadNos387.8387.820.0FalseNoneNoneFalseNoneFalse7756.00
3046767102981NonePWD SR 2023-24 V-6 Page No 90 Item No 15.93Supplying Installing, testing and commissioning of approved make 15mm dia sprinkler bulb pendent/wall mounted type designed to operate 68 degrees centegrad Make Tyco/HD FIRE complete (Colour code of bulb liquid inside Glass bulb type Pendents As per IS 9972: 57 DegreeCOrange, 68 DegreeC - Red, 79 DegreeC - Yellow, 93 DegreeC - Green, 141 DegreeC - Blue, 182 DegreeC Mauve, 227/260 DegreeC - Black) ---- etc., complete with all leadEach464.62464.62400.0FalseNoneNoneFalseNoneFalse185848.00
3046768102981NonePWD SR 2023-24 V-6 Page No 94 Item No 15.122Stainless steel braided flexible pipe (hose) for dropping sprinklers below false ceiling, pipe shall be 16 bar pressure rating and 1500 mm long 25 mm dia with union / reducer collar, clamps etc. as required. ---- etc., complete with all leadEach3097.53097.550.0FalseNoneNoneFalseNoneFalse154875.00
3046769102981NonePWD SR 2023-24 V-6 Page No 94 Item No 15.120.Supplying Installing, testing and commissioning of Ceiling Mounted powder coated Surface Finishing Mild Steel Rosette Plate including cost of materials, labour, usage charges of machinery complete as per specifications ---- etc., complete with all leadEach136.29136.2950.0FalseNoneNoneFalseNoneFalse6814.50
3046770102981NonePWD SR 2023-24 V-6 Page No 100 Item No 15.163Supply, erection, testing and commissioning of 1" GI/MS collar. ---- etc.,complete with all leads And lifts as per specifications and as directed by the Engineer-in-charge . ---- etc., complete with all leadNos136.29136.29450.0FalseNoneNoneFalseNoneFalse61330.50
3046771102981NonePWD SR VOL-2 Page No 82 Item No 11.16.2Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all leadKg182.13182.131500.0FalseNoneNoneFalseNoneFalse273195.00
3046772102981NonePWD SR 2023-24 V-6 Page No 68 Item No 15.22FIRE EXTINGUSHERS & SIGN BOARD: Supply and installation of 2Kg Pressure type, Pressure Guage, Gross Weight 3.7Kg, empty weight 1.7 Kg, Can Height 344MM, Diameter 108MM, Discharge Time less than 8 Sees, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 2 meters, applicable on Class A,8,C and electrically started Fire, 8 Rating 218, Can construction: Deep drawn &Co., Mig welded, valve Construciton: Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy PoIyster power coating, Sheet metal thickness: 2.00 MM, 5 years warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost cost of supporting materials like MS stand & accessaries if it is fixing n floor / MS brackets & accessories if it is fixing on wall,, labour, usage charges of machinery complete as per specifications. complete IS15683 and CE Approved. ---- etc., complete with all leadEach8053.58053.54.0FalseNoneNoneFalseNoneFalse32214.00
3046773102981NonePWD SR 2023-24 V-6 Page No 72 Item No 15.33CO2 2Kg Squeeze grip Providing 2 Kg C02 Gas Type Fire Extinugisher Squeeze grip type, used Unused Mechanism, Squeeze Grip, Gross Weight 9.1 Kg. empty Weight 7.1 Kg. Can Height 595MM Diameter 108MM, Discharge Time less than 8 Sees, Controllable discharge mechanism, Applicable on Class 8&C Fire, 8 Rating 88, Can Construction : Hot spinning/Forging, Valve Construction : Forging & Machining, Internal Coating of Can : Not Applicable, External coating of Can : Spray Painting, Sheet metal thickness: 4.0MM lSI Approved, 1 Year Warranty.with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete ---- etc., complete with all leadEach6814.56814.55.0FalseNoneNoneFalseNoneFalse34072.50
3046774102981NonePWD SR 2023-24 V-6 Page No 74 Item No 15.4Providing Aqueous Film-Forming Foam - 9 Ltr Providing 9 Ltr Fire Extinugisher Aqueous Film-Forming Foam Type, Stored Pressure Type, Pressure Gauge, Gross Weight 15.1Okg. empty weight 6.10kg Can Height 615 MM, Diameter 175 MM, Discharge Time less than 60 Sees, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 6 Meters, applicable on Class A,8,CARating 13A, 8 Rating 558, Can Construction;Deep drawn & CO, Mig welded, Valve Construction: Forging & Machining, Internal Coating of Can : Epoxy Powder coating, External Coating of Can : Epoxy PoIyster Powder coating, Sheet metal thickness: 2.0MM, lSI and EN Approved, Helium Leak Detection Tested, 1 Years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete ---- etc., complete with all leadEach10035.910035.92.0FalseNoneNoneFalseNoneFalse20071.80
3046775102981NonePWD SR 2023-24 V-6 Page No 62 Item No 15.4Providing ABC Powder based MAP 50, 6Kg:-Providing 6kg Fire Extinguisher Mono Ammonium Phos phate Powder 50, Stored Pressure Type, Pressure Gauge, Gross Weight 9.5 Kg, empty weight 3.5 Kg, Can Height 435MM, Diameter 160MM, Discharge Time less than 9 Sees, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 4 meters, applicable on Class A,8,C and electrically started Fire, A Rating 3A, 8 Rating 218, Can construction : Deep drawn & Co., Mig welded, valve Construciton : Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy PoIyster power coating, Sheet metal thickness: 1.60MM, 5 years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete. IS 15683 Approved, ---- etc., complete with all leadEach3531.153531.155.0FalseNoneNoneFalseNoneFalse17655.750
3046776102981NonePWD SR 2023-24 V-6 Page No 72 Item No 15.34Supply, installation in position, testing and commissioning of 4.5Kg C0 Gas Type Fire Extinugisher, Trolley Mounted, 2 Easy Weight Management used Unused Mechanism, Squeeze Grip, Gross Weight 19.1 Kg. empty Weight 14.6 Kg. Can Height 860MM Diameter 140MM, Discharge Time less than13 Sees, Controllable discharge mechanism, Applicable on Class 8&C Fire, 8 Rating 138, Can Constuctin : Hot spinning/Forging, Valve Construction : Forging & Machining, Internal Coating of Can : Not Applicable, External coating of Can : Spray Painting, Sheet metal thickness : 4.5M M lSI Approved 1Year Warranty. with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete ---- etc., complete with all leadEach8053.58053.55.0FalseNoneNoneFalseNoneFalse40267.50
3046777102981NonePWD SR 2023-24 V-6 Page No 93 Item No 15.112Supplying of two bucket stand alongwith buckets. complete ---- etc., complete with all leadEach1362.91362.94.0FalseNoneNoneFalseNoneFalse5451.60
3046778102981NonePWD SR -21-22 Page No 14 Item No 15.72Providing and fixing in position the following type of sign boards made out of 3mm thick "Opaque" PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners. Providing's Escape Singage Photoluminescent rigid plastic, 2 mm thickness, Printed on High Quality glass paint with UV resistance, 5 years warranty, Material Used - Non Radiocactive, non-phosphorous, non toxic and lead free. Available in different types & sizes, Time after removing the light source (in minutes) 60 minutes, Luminescent intensity (milicandelas * per square meter - mcd/sqm) : 30 mcd/sqm.Luminescent Intensity greater than 0.32 mcd/sqm, Period of Light Decay* (In Minutes) :3100, including cost of materials, labour, usage charges of machinery complete as per specifications.(Signage with the following text "IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE" Size:-25cm x 30 cm) ---- etc., complete with all leadSq CM2.482.481500.0FalseNoneNoneFalseNoneFalse3720.00
3046779102981NonePWD SR -21-22 Page No 14 Item No 15.72Providing's Escape Singage Photoluminescent rigid plastic, 2 mm thickness, Printed on High Quality glass paint with UV resistance, 5 years warranty, Material Used - Non Radiocactive, non-phosphorous, non toxic and lead free. Available in different types & sizes, Time after removing the light source (in minutes) 60 minutes, Luminescent intensity (milicandelas * per square meter - mcd/sqm) : 30 mcd/sqm.Luminescent Intensity greater than 0.32 mcd/sqm, Period of Light Decay* (In Minutes) :3100, including cost of materials, labour, usage charges of machinery complete as per specifications.(Floor identification signage ( ie, GROUND FLOOR …etc.) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 7.5 cm with contrasting colour from back ground.Size shall be 15cm x 60cm.) ---- etc., complete with all leadSq CM2.482.481800.0FalseNoneNoneFalseNoneFalse4464.00
3046780102981NonePWD SR 21-22 Page No 14 Item No 15.72Providing's Escape Singage Photoluminescent rigid plastic, 2 mm thickness, Printed on High Quality glass paint with UV resistance, 5 years warranty, Material Used - Non Radiocactive, non-phosphorous, non toxic and lead free. Available in different types & sizes, Time after removing the light source (in minutes) 60 minutes, Luminescent intensity (milicandelas * per square meter - mcd/sqm) : 30 mcd/sqm.Luminescent Intensity greater than 0.32 mcd/sqm, Period of Light Decay* (In Minutes) :3100, including cost of materials, labour, usage charges of machinery complete as per specifications.(signage with text FIRE EXIT,Size shall be 15cm x 60cm.) ---- etc., complete with all leadSq CM2.482.481800.0FalseNoneNoneFalseNoneFalse4464.00
3046781102981NonePWD SR 2023-24 V-6 Page No 92 Item No 15.106Providing and fixing in position the signages "FIRE ORDER" it should contain the following text on 3mm thick "Opaque" PVC foam board of computerized cut, PVC non-reflective self adhesive vinyl painted foam board of size 3' x 4'. A) ALERT THE SECURITY AT SECURITY ROOM BY ACTUATING MANUAL CALL POINT LOCATED AT STRATEGIC LOCATIONS. B) EVACUATE THE OCCUPANTS BY USING FIRE EXITS AND EMERGENCY EXITS ONLY AND ASSEMBLE AT VARIOUS ASSEMBLY POITS. C) IF POSSIBLE TRY TO EXTINGUISH THE FIRE BY USING NEAREST / SUITABLE PORTABLE EXTINGUISHER OR WATER FROM NEAREST WET RISER. D) BE CALM AND DO NOT GIVE ANY ROOM FROM PANIC, WALK, DO NOT RUN. E) IF YOU ENCOUNTER SERIOUS DIFFICULTY IN EVACUATION, LIE DOWN FLAT AND TRY TO ATTRACT ATTENTION OF RESCUE TEAM. ---- etc., complete with all leadEach3097.53097.52.0FalseNoneNoneFalseNoneFalse6195.00
3046782102981NonePWD SR 2023-24 PWD SR Page No 92 Item No 15.106ACTION BY SECURITY/RECEPTION UPON RECEIPT OF INFORMATION THROUGH FIRE ALARM OR FIRE DETECTORS OR BY USING PUBLIC ADDRESS SYSTEM. A) ALERT THE OCCUPANTS BY USING PUBLIC ADDRESS SYSTEM. B) INFORM FIRE CONTROL THROUGH ANY ONE OF THE FOLLOWING PHONE NUMBERS: (Current phone numbers to be provided in this location by the contractor) C) REFER EVACUATION PLAN FROM EVACUATING STANDARD PEOPLE. D) GUIDE THE FIRE FORCE, ON THEIR ARRIVAL TO THE SEAT OF FIRE. E) IN CASE OF THE CASUALTIES, CALL AMBULANCE BY DIALLING NUMBER: (Current phone numbers to be provided in this location by the contractor) F) FIRE FIGHTING AGENCY: PHONE : (Current phone numbers to be provided in this location by the contractor) FAX : (Current fax numbers to be provided in this location by the contractor) ---- etc., complete with all leadEach3097.53097.52.0FalseNoneNoneFalseNoneFalse6195.00
3046783102981NonePWD SR 21-22 Page No 14 Item No 15.72Providing's Escape Singage Photoluminescent rigid plastic, 2 mm thickness, Printed on High Quality glass paint with UV resistance, 5 years warranty, Material Used - Non Radiocactive, non-phosphorous, non toxic and lead free. Available in different types & sizes, Time after removing the light source (in minutes) 60 minutes, Luminescent intensity (milicandelas * per square meter - mcd/sqm) : 30 mcd/sqm.Luminescent Intensity greater than 0.32 mcd/sqm, Period of Light Decay* (In Minutes) :3100, including cost of materials, labour, usage charges of machinery complete as per specifications.(route plan Fire Escape Route Plan A2 Size) ---- etc., complete with all leadEach2.472.472494.0FalseNoneNoneFalseNoneFalse6160.180
3046784102981NoneLeast Quotation RateTWO WAY TACK BACK & PA SYSTEM: Supply installation testing commissioning of P.A System Rack made out of 18 gauge M.S. Sheet with glass door with locking arrangement and powder coating grey paint two coats at inner and outer of box, is to accomodated 1 No. 250 watt amplifire, 1 No. 40 zone console and 1 no Mike and in built electronic connections circuits.Size or Rack: 0.50 m hight x 0.40 m width x 0.40 m depth ---- including all lead and lift charges loading and unloading charges labour charges, curing, cost& conveyance of all materials, transportation charges, all incidental charges, hire charges of all machinery and equipment required for successful completion of work etc., complete. The work shall be executed as per standard technical specification and directions of Engineer in charge of the work ---- etc., complete with all leadNos58410.058410.01.0FalseNoneNoneFalseNoneFalse58410.00
3046785102981NonePWD SR 2023-24 V-6 Page No 92 Item No 15.108.3Supplying Installing, testing and commissioning of P.A.System console panel with push button with speaker and indictoron Accomdated in M.S.Cabinet with painting -do- 40 Zone cansole. Complete ---- etc., complete with all leadNos100359.0100359.01.0FalseNoneNoneFalseNoneFalse100359.00
3046786102981NonePWD SR 2023-24 V-6 Page No 93 Item No 15.109P.A.System amplifier 250W RMS out put with complete wiring and controls accessable form front ---- etc., complete with all leadNos43674.7543674.751.0FalseNoneNoneFalseNoneFalse43674.750
3046787102981NonePWD SR 2023-24 V-6 Page No 93 Item No 15.109Supplying Installing, testing and commissioning of MIKE ---- etc., complete with all leadEach6814.56814.51.0FalseNoneNoneFalseNoneFalse6814.50
3046788102981NonePWD SR 2023-24 V-6 Page No 92 Item No 15.107Supplying Installing, testing and commissioning of Public address system (Two way comminication type) as per requirement of Fire Force authority and which Generally comprise of Supplying Installing, testing and commissioning of Approved make 5W.wall mounted speaker with talk back facility with store enamel painted M.S.Sheet hosing etc. complete including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all leadEach3035.553035.552.0FalseNoneNoneFalseNoneFalse6071.10
3046789102981NoneCPWD-21-22 Page No Item No 15.105Supply & Laying of 2 X 1.5 Sqmm fire alarm armored cable,600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. ---- etc., complete with all leadMtr185.85185.85500.0FalseNoneNoneFalseNoneFalse92925.00
3046790102981NonePWD SR 2023-24 V-6 Page No 84 Item No 15.66.1FIRE ALARM SYSTEM: Supply, install, test and commissioning of addressable peer to peer Networkable analogue addressable type fire alarm control panel with minimum 1500 Character /240X64 Pixel / 7inch Touchscreen graphic LCD display. The panel should be equipped with sufficient numbers of loop with 20% spare capacity, with each networkable intelligent fire alarm Control Panel having SLC with capacity of min 126/240 detectors/ devices in any combination with key pad, dual flash-based microprocessor technology, inbuilt USB Port for upload and down load the configuration tools, RS232 serial port for direct PC or modem connection, inbuilt NAC's, min 20 programmable Zonal LEDs and operates on 240V AC + 10% with 50Hz with built in charger. The panel shall have fire, fault relays, option of BMS integration MODBUS/ BACKNET, graphical software for provision of TCP/ IP modules, Remote Access, Class 'X' wiring with provision of both class 'A' and class 'B' wiring in the SLC circuit, user friendly with communication facility to monitor & control the FACPs from a single window. The panel shall be suitable for minimum of 5000 event record facility, event fetch from FACP facility and the single panel shall be suitable for min 2000 fire zones and 200 Panels/ Nodes in one network with all other accessories required to successfully run the system. (The System cost shall be included of all necessary cards, modules, Panel enclosure, CPU and associated accessories to complete the system design). Approval: VDS/UL/EN-54 Std. 2 Loop Panel ---- etc., complete with all leadEach260190.0260190.02.0FalseNoneNoneFalseNoneFalse520380.00
3046791102981NoneCPWD 17.202Supply, intallation, testing and Commissioning of Graphical software for entire fire alarm panels including detector configuration, commissioning etc ---- etc., complete with all leadEach248557.03248557.031.0FalseNoneNoneFalseNoneFalse248557.030
3046792102981NoneLeast Quotation RateSupply, intallation, testing and Commissioning of Network card for fire alram panels integration ---- etc., complete with all leadEach75000.075000.02.0FalseNoneNoneFalseNoneFalse150000.00
3046793102981NonePWD SR 2023-24 V-6 Page No Item No 15.103Supplying Installing, testing and commissioning of Response Indicator constists of twin LED wioth electronic circutarx work on 24 DC enclose in PVC retangular. complete including cost of materials, labour, HOM complete as per specifications. ---- etc., complete with all leadEach309.75309.7525.0FalseNoneNoneFalseNoneFalse7743.750
3046794102981NonePWD SR 2023-24 V-6 Page No 84 Item No 15.67Supply, Installation , Testing & Commissioning  of Network Active Repeater Panel with 1500 Character / 240X64 Pixel / 7inch Touchscreen. The LCD shall Display all events / detectors, devices status of complete systems in the networked.  Approval: UL/VDS/EN54. Make: ---- etc., complete with all leadEach80535.080535.01.0FalseNoneNoneFalseNoneFalse80535.00
3046795102981NonePWD SR 21-22 Page No Item No 15.66Supply, intallation, testing and Commissioning of loop card ---- etc., complete with all lead& lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all leadEach3469.23469.22.0FalseNoneNoneFalseNoneFalse6938.40
3046796102981NonePWD SR 2023-24 V-6 Page No 92 Item No 15.1Supply Installation testing & Commissioning of conventional type photo/Heat electric smoke sensor with flashing LED capable of woking at 9V to 33 V DC .The Optical Smoke Detector is unaffected by wind or atmosphericpressure and operates over the temperature range -20 DegreeC to +60 DegreeC. IP Rating at IP 23D & Approval with EN-54 -7, LPCB Approved. ---- etc., complete with all leadEach2601.92601.9200.0FalseNoneNoneFalseNoneFalse520380.00
3046797102981NoneLeast Quotation RateSITC OF Fault isolation module:- Supply, Erection,Testing and Commissioning of UL-APPROVED Analog addressable fault isolator circuit modules of wall mounted type with mounting accessories. ---- etc., complete with all leadEach7080.07080.010.0FalseNoneNoneFalseNoneFalse70800.00
3046798102981NonePWD SR 2023-24 V-6 Page No 84 Item No 15.68Supply, Installation, Testing & Commissioning of Analogue Addressable loop powered Sounder & Beacon  with inbuilt isolator and  having Min 15 distinct sound patterns/ multitone to indicate Exit doors and direct occupants for safe and fast evacuation and 100dB output with minimum 1Hz Frequency flash rate designed for IP65 requirements and approved to operate in -10 DegreeC to +55 DegreeC temperature, complies with the essential requirement of the EMC Directive to be supplied with Junction Box, Glands and other mounting accessories for proper installation. (For Detectors/Device without inbuilt isolator, Fault Isolator or Isolator base to be provided with each detector/device) Approval: VDS/UL/EN54. Make: Advanced (UK),Simplex, Notifier, Argus(Uk) ---- etc., complete with all leadEach6071.16071.12.0FalseNoneNoneFalseNoneFalse12142.20
3046799102981NonePWD SR 2023-24 V-6 Page No 85 Item No 15.73Supplying Installing, testing and commissioning of Resettable type Manual Call point . works on 24V DC LED indicator with glass Fronted. Fire Symbol .The red Manual Call Point is approved to EN54-11 standard. MECHANICAL CONSTRUCTION The component parts of the call point are moulded in polycarbonate or ABS, depending on their function. ---- etc., complete with all leadEach3717.03717.02.0FalseNoneNoneFalseNoneFalse7434.00
3046800102981NonePage No 2 Item No 1.4.2Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.100 x 75 x 65 mm ---- etc., complete with all leadEach146.2146.2200.0FalseNoneNoneFalseNoneFalse29240.00
3046801102981NonePWD SR 2023-24 PWD SR Page No 85 Item No 15.72Supply, install, test and commissioning of Analogue addressable Monitor Cum Control (Input/Output) module (1+1) with inbuilt relay and isolator with LED indicator, approved to operate in -10 DegreeC to +55 DegreeC temperature, complies with the essential requirement of the EMC Directive to be supplied with Junction Box, Glands and other mounting accessories for proper installation. In case of Manufacturer with single Input or Output module need to supply One quantity of each for line item.(For Detectors/Device without inbuilt isolator, Fault Isolator or Isolator base to be provided with each detector/device) Approval: EN54. ---- etc., complete with all leadEach4832.14832.12.0FalseNoneNoneFalseNoneFalse9664.20
3046802102981NoneCPWD - ELECTRICAL SR 15.105Supply, intallation, testing and Commissioning of 2C 1.5 sq mm armoured FRLS cables in celing with suitable clamps and screws (RED colour) ---- etc., complete with all leadMtr185.85185.851300.0FalseNoneNoneFalseNoneFalse241605.00
3046803102981NonePWD SR-21-22 Page No 90 Item No 15.113SITC of 7AM-12 V Battery for fire alarm system ---- etc., complete with all leadEach1326.961326.964.0FalseNoneNoneFalseNoneFalse5307.840
17103318720000NoneNoneBuildingsHVAC13553875.3
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3046804102982NoneItem 6.8.4Supplying of ..... TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 230V/50Hz with hermetically sealed inverter compressor with air cooled condenser, latest R410A / R-32 Refrigerant fan motor, start & run capacitors, relay & over load protector internal unit, with one indoor & one outdoor unit. The condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. Suitable capacity 3 Core sheathed/PVC copper cable and a battery operated wireless remote unit. 1 Ton capacity ---- etc., complete with all leadNos58923.1258923.125.0FalseNoneNoneFalseNoneFalse294615.60
3046805102982NoneItem 6.8.5Supplying of ..... TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 230V/50Hz with hermetically sealed inverter compressor with air cooled condenser, latest R410A / R-32 Refrigerant fan motor, start & run capacitors, relay & over load protector internal unit, with one indoor & one outdoor unit. The condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. Suitable capacity 3 Core sheathed/PVC copper cable and a battery operated wireless remote unit. 1.5 Ton capacity ---- etc., complete with all leadNos69823.8569823.856.0FalseNoneNoneFalseNoneFalse418943.10
3046806102982NoneItem 6.8.6Supplying of ..... TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 230V/50Hz with hermetically sealed inverter compressor with air cooled condenser, latest R410A / R-32 Refrigerant fan motor, start & run capacitors, relay & over load protector internal unit, with one indoor & one outdoor unit. The condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. Suitable capacity 3 Core sheathed/PVC copper cable and a battery operated wireless remote unit. 2 Ton capacity ---- etc., complete with all leadNos83507.3683507.365.0FalseNoneNoneFalseNoneFalse417536.80
3046807102982NoneItem 6.9.1Supply erection, testing, and commissioning of Cassette type split Air conditioners suitable for operation on single/three phase AC supply, hermetically sealed compressor with air cooled condenser motor capacitor start, capacitors run relay and overload protection, one ceiling mounted indoor unit and one outdoor condenser unit including standard accessories covered with insulation tube including battery operated cordless unit. 2.0 TR Cassette 1 Ph ---- etc., complete with all leadNos97652.097652.01.0FalseNoneNoneFalseNoneFalse97652.00
3046808102982NoneItem 6.10.1Supply, erection, testing, commissioning of package type Duct able type split Air-Conditioner with microprocessor control, fitted with twin scroll Compressor with R22/Latest Refrigerant. The unit shall be pre-wired to operate on 415V/50Hz AC Supply. The unit shall comprise, Evaporated condenser unit, Indoor-Outdoor Motor Fans, suitable over vent fins made up of Aluminium, Copper Refrigerant coil, Etc.,. complete and corded control unit. 3.0 TR ---- etc., complete with all leadNos106313.63106313.631.0FalseNoneNoneFalseNoneFalse106313.630
3046809102982NoneItem 6.10.2Supply, erection, testing, commissioning of package type Duct able type split Air-Conditioner with microprocessor control, fitted with twin scroll Compressor with R22/Latest Refrigerant. The unit shall be pre-wired to operate on 415V/50Hz AC Supply. The unit shall comprise, Evaporated condenser unit, Indoor-Outdoor Motor Fans, suitable over vent fins made up of Aluminium, Copper Refrigerant coil, Etc.,. complete and corded control unit. 5.5 TR ---- etc., complete with all leadNos140142.0140142.02.0FalseNoneNoneFalseNoneFalse280284.00
3046810102982NoneItem 6.10.3Supply, erection, testing, commissioning of package type Duct able type split Air-Conditioner with microprocessor control, fitted with twin scroll Compressor with R22/Latest Refrigerant. The unit shall be pre-wired to operate on 415V/50Hz AC Supply. The unit shall comprise, Evaporated condenser unit, Indoor-Outdoor Motor Fans, suitable over vent fins made up of Aluminium, Copper Refrigerant coil, Etc.,. complete and corded control unit. 8.5 TR ---- etc., complete with all leadNos201440.34201440.341.0FalseNoneNoneFalseNoneFalse201440.340
3046811102982NoneItem 6.12Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable angle iron support upto 3.0 Ton split/cassette type A/C. ---- etc., complete with all leadNos3833.833833.8316.0FalseNoneNoneFalseNoneFalse61341.280
3046812102982NoneItem 6.13.1Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit leak testing oil and gas charging for additional piping length of tube. Split ---- etc., complete with all leadm1919.211919.2160.0FalseNoneNoneFalseNoneFalse115152.60
3046813102982NoneItem 6.13.2Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit leak testing oil and gas charging for additional piping length of tube. Cassette ---- etc., complete with all leadm2030.722030.7215.0FalseNoneNoneFalseNoneFalse30460.80
3046814102982NoneItem 6.25.1Supply, fabrication and installation of GI Ducting Along with flanges, supports & all fixing materials. 24 Gauge ---- etc., complete with all leadSqm2243.832243.83900.0FalseNoneNoneFalseNoneFalse2019447.00
3046815102982NoneItem 6.25.2Supply, fabrication and installation of GI Ducting Along with flanges, supports & all fixing materials. 22 Gauge ---- etc., complete with all leadSqm2627.022627.0210.0FalseNoneNoneFalseNoneFalse26270.20
3046816102982NoneItem 6.26Supply and installation of Thermal insulation using 13mm nitrile rubber for return air ducts. ---- etc., complete with all leadSqm1475.651475.65750.0FalseNoneNoneFalseNoneFalse1106737.50
3046817102982NoneItem 6.27Supply and installation of Tarpaulin canvas between the AC duct and AC evaporator unit including accessories. ---- etc., complete with all leadNos5654.85654.811.0FalseNoneNoneFalseNoneFalse62202.80
3046818102982NoneItem 6.29.1Supply and installation of Powder coated aluminium diffusers of size 595x595mm for supply & return air. Aluminium Diffusers ---- etc., complete with all leadNos6291.646291.64220.0FalseNoneNoneFalseNoneFalse1384160.80
3046819102982NoneItem 6.29.2Supply and installation of Powder coated aluminium diffusers of size 595x595mm for supply & return air. Collar Dampers ---- etc., complete with all leadNos3251.143251.14100.0FalseNoneNoneFalseNoneFalse325114.00
3046820102982NoneItem 6.29.3Supply and installation of Powder coated aluminium diffusers of size 595x595mm for supply & return air. GI Mixing Box ---- etc., complete with all leadNos7774.737774.7320.0FalseNoneNoneFalseNoneFalse155494.60
3046821102982NoneItem 6.29.4Supply and installation of Powder coated aluminium diffusers of size 595x595mm for supply & return air. Flexible Duct Per Mtr ---- etc., complete with all leadNos2096.392096.3920.0FalseNoneNoneFalseNoneFalse41927.80
3046822102982NoneItem 6.30.2Supply and fixing of powder coated extruded aluminium grill suitable for supply/return air including all fixing hardware etc.,. Complete. 6" Extruded aluminium grille with 15 deg to 30 deg louvers. ---- etc., complete with all leadm2108.782108.7830.0FalseNoneNoneFalseNoneFalse63263.40
3046823102982NoneItem 5.1Supplying push button operated direct online starter with anantiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overloadrelay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for230/440 V 1/3 phase motor upto 5 HP. ---- etc., complete with all leadNos2387.552387.5511.0FalseNoneNoneFalseNoneFalse26263.050
3046824102982NoneItem MRSupply, Installation, Testing and Commissioning of Customized Double Skin Horizontal Ceiling Mounted type Air Handling Units with Thermal Break profile. (Direct Expansion (DX) refrigerant to air evaporator coils, as applied with condensing units with necessary KIT) Sandwitched between 0.8 precoated GI (outer skin) shall be pre coated and 0.8 Plain GI (inner skin) double skin (48 2 mm) insulated with CFC free polyurethane foam (PUF) panels of 40 Kg/cum density. AHU frame works shall be of pre cast vertical and horizontal extruded thermal break aluminium profile with three way corner frame sections. Food grade self adhesive coated neoprene gasket to be provided between panels and structure of the AHU to ensure the entire housing is airtight. DIDW centrifugal belt driven backward Aerofoil curved impeller fans (Efficiency with 75%) (AMCA Certified) to be supplied along with motor.The outlet velocity will not exceed 9.5 m/sec. Vibration isolatator to fans and motor to avoid transmission of vibration. AHRI Certified DX Cooling coils shall be of minimum 6/8 Row deep or as per computer coil selections which ever is greater. Face Velocity across the coils should not exceed 500 FPM (2.5m/s) (Note : DX Cooling Coil should be Hydrophlic blue aluminium fines.) The AHU unit shall be complete with external DX type condensing unit, complete in all respects, inclusive of complete working charge of R410a/134a Chlorofluorocarbons (CFC) environmentally free refrigerant.Drain tray for DX cooling coils shall be made of single sheet of SS 304-20G grade stainless steel sheet and should have uniform slope from all sides leading to drain connection. Drain Pan shall be insulated with 19mm thick, 55kg/cum density closed cell elastomeric insulation. Each unit filters section shall be provided with a factory assembled filter section containing washable synthetic with 50mm thick panel type Pre-Filter of MERV 8 (EU-4)- 90% down to 10 microns. (1 set of spare & 1 set of commissioning pre filters should be consider) and Fine-Filter of MERV 13 (EU-7) 97% down to 3 microns. The Motor shall be of TEFC, IP-65 protected, IE-3, Class 'F' insulation, suitable for 3 phase, 415 volts, 50hz power supply. Motor shall be VFD compatible and induction type. Costing is inclusive of Canvas connection made of self extinguishing, moisture resistant flexible fabric to be provided between AHU outlet flange and the supply duct / plenum, communication cable as specfied by manufacturer and Lifting, Shifting & Positioning with MS L angle base frame structure duly black painted with synthetic epoxy paint for all outdoor units. Wiring and earthing, vacuum cleaneing, gas charging, pressure testing and etc… are in part of HVAC Vendor scope.Safety interlock switch for fan operation to controle heater on/off to be provided by the AHU manufacturer. Note : Costing is inclusive of Necessary DX type condensing out door units to AHU interface Expansion Connecting Kit (PCB with EEV) & Control Control Panel with sensors, thermostat and etc.., Corded Remote controller for AHU's to precisely control the flow of refrigerant for temperature control. 3.0 TR / 1,200 CFM with 50 TSP - 1.1 Kw (approx) for CSU's and 1x3.0 - Condensing units with necessary KIT ---- etc., complete with all leadNos173460.0173460.02.0FalseNoneNoneFalseNoneFalse346920.00
3046825102982NoneItem MR5.5 TR / 2,200 CFM with 50 TSP - 1.5 Kw (approx) for CSU's and 1x5.5 - Condensing units with necessary KIT ---- etc., complete with all leadNos265972.0265972.02.0FalseNoneNoneFalseNoneFalse531944.00
3046826102982NoneItem MR6.5 TR / 1,500 CFM with 50 TSP - 1.1 Kw (approx) for CSU's and 1x8.5 - Condensing units with necessary KIT ---- etc., complete with all leadNos303850.0303850.01.0FalseNoneNoneFalseNoneFalse303850.00
3046827102982NoneItem MR8.5 TR / 3,400 CFM with 50 TSP - 1.5 Kw (approx) for CSU's and 1x8.5 - Condensing units with necessary KIT. ---- etc., complete with all leadNos362260.0362260.03.0FalseNoneNoneFalseNoneFalse1086780.00
3046828102982NoneItem MRSupply, Installation, Testing and Commissioning of Double Skin Horizontal Ceiling/Floor Mounted Cabinet type Fresh air Units Sandwitched between 0.6 precoated GI (outer skin) shall be pre coated and 0.6 Plain GI (inner skin) double skin (23 2 mm) insulated with CFC free polyurethane foam (PUF) panels of 40 Kg/cum density. with DIDW centrifugal belt driven backward curved Aerofoil impeller fans (Efficiency with 75%) (AMCA Certified) to be supplied along with motor. Vibration isolatator to fans and motor to avoid transmission of vibration, Motor, Pulleys, Belts & Belt guard, Pre-Filter of MERV 8 (EU-4)- 90% down to 10 microns. Drive sets, base frame, spring mounts, Limit switches, Marine lamp, Inspection door and all necessary accessories.Blower Make - Nicotra / Kruger. The unit shall be suitable for outdoor application with necessary weather hood, canopy and supports with necessary MS channels & threaded rods. The Motor shall be of TEFC, IP-55 protected, IE-3, Class 'F' insulation, suitable for 3 phase, 415 volts, 50hz power supply. Motor shall be VFD compatible and induction type. VFD starter panel cost quantified separately (Cost excluded for the same).Costing is inclusive of Factory fabricated non-cloth type Fire retardant flexible connection made of high quality self extinguishing, moisture resistant flexible fabric with matching angle flanges between Fresh air units outlet flange and the connected plenum or ducts. 1,350 CFM / 40 mm TSP / 1.1 kW (approx) ---- etc., complete with all leadNos47790.047790.01.0FalseNoneNoneFalseNoneFalse47790.00
3046829102982NoneItem MRSupply, Installation, Testing and Commissioning of Double Skin Horizontal Ceiling/Floor Mounted Cabinet type Fresh air Units Sandwitched between 0.6 precoated GI (outer skin) shall be pre coated and 0.6 Plain GI (inner skin) double skin (23 2 mm) insulated with CFC free polyurethane foam (PUF) panels of 40 Kg/cum density. with DIDW centrifugal belt driven backward curved Aerofoil impeller fans (Efficiency with 75%) (AMCA Certified) to be supplied along with motor. Vibration isolatator to fans and motor to avoid transmission of vibration, Motor, Pulleys, Belts & Belt guard, Pre-Filter of MERV 8 (EU-4)- 90% down to 10 microns. Drive sets, base frame, spring mounts, Limit switches, Marine lamp, Inspection door and all necessary accessories.Blower Make - Nicotra / Kruger. The unit shall be suitable for outdoor application with necessary weather hood, canopy and supports with necessary MS channels & threaded rods. The Motor shall be of TEFC, IP-55 protected, IE-3, Class 'F' insulation, suitable for 3 phase, 415 volts, 50hz power supply. Motor shall be VFD compatible and induction type. VFD starter panel cost quantified separately (Cost excluded for the same).Costing is inclusive of Factory fabricated non-cloth type Fire retardant flexible connection made of high quality self extinguishing, moisture resistant flexible fabric with matching angle flanges between Fresh air units outlet flange and the connected plenum or ducts. 2,000 CFM / 40 mm TSP / 1.5 Kw (approx) ---- etc., complete with all leadNos70800.070800.02.0FalseNoneNoneFalseNoneFalse141600.00
3046830102982NoneItem MRSupply, Installation, Testing and Commissioning of Double Skin Horizontal Ceiling/Floor Mounted Cabinet type Exhaust Units Sandwitched between 0.6 precoated GI (outer skin) shall be pre coated and 0.6 Plain GI (inner skin) double skin (23 2 mm) insulated with CFC free polyurethane foam (PUF) panels of 40 Kg/cum density. with DIDW centrifugal belt driven backward curved Aerofoil impeller fans (Efficiency with 75%) (AMCA Certified) to be supplied along with motor. Vibration isolatator to fans and motor to avoid transmission of vibration, Motor, Pulleys, Belts Belt guard, HEPA Filter 99.99% down to 0.03 microns. Drive sets, base frame, spring mounts, Limit switches, Marine lamp, Inspection door and all necessary accessories..Blower Make - Nicotra / Kruger. The unit shall be suitable for outdoor application with necessary weather hood, canopy and supports with necessary MS channels & threaded rods. The Motor shall be of TEFC, IP-55 protected, IE-3, Class 'F' insulation, suitable for 3 phase, 415 volts, 50hz power supply. Motor shall be VFD compatible and induction type. VFD starter panel cost quantified separately (Cost excluded for the same).Costing is inclusive of Factory fabricated non-cloth type Fire retardant flexible connection made of high quality self extinguishing, moisture resistant flexible fabric with matching angle flanges between Fresh air units outlet flange and the connected plenum or ducts. 1,800 CFM / 70 mm TSP / 2.2 kW (approx) ---- etc., complete with all leadNos84960.084960.01.0FalseNoneNoneFalseNoneFalse84960.00
3046831102982NoneItem MRSupply, Installation, Testing & Commissioning of Rectangular / Circular inline fan with variable speed regulator with suitable for installing in any position in vertical or horizontal ducts. All accessories like fan, motor, flanges, non-canvass type fire retardant flexible connections, etc., The impeller shall be of forward type. The motor should be of IP21, class 'B' insulation suitable for operating at 1phase, 230V, 50hz power supply. Note : Rectangular / Circular inline fan shall have low sound level exceeding not more than 40 dBA at 1 meter distance. Note: Costing is inclusive of Factory fabricated non-cloth type Fire retardant flexible connection made of high quality self extinguishing, moisture resistant flexible fabric with matching angle flanges between Fresh/Exhaut air units outlet flange and the connected plenum or ducts. 300 CFM / 20mm TSP. ---- etc., complete with all leadNos12390.012390.02.0FalseNoneNoneFalseNoneFalse24780.00
3046832102982NoneItem MRSupply, installation, testing and commissioning of Interconnecting Soft drawn / Hard drawn Refrigerant copper Piping with insulation with UV protection coating. Note: a) To protect Nitrile rubber insulation of outdoor installed copper piping from degradation due to ultra violet rays and atmospheric condition. b) UV protection coating on existing copper pipes (with insulation) shall be done with the help of starbond and 7mm cloth etc. UV protection coating shall be done on all the pipes irrespective of size of pipes work duly insulated with 13mm & 19mm thick elastomeric nitrile rubber type tubular insulation between VRV/VRF/DX Type indoor & outdoor units. Note : a) Costing is inclusive of necessary supports & supporting rods, saddles at 1m interval. b) Refrigerant copper Piping quantity (Rmt) to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity. c) Actual measurement of Refrigerant copper Piping quantity (Rmt) should be taken as per site condition only. 1/4" (6.35 mm) X 21 Swg (0.8 mm) - Soft drawn (Insulation = 13mm thick) ---- etc., complete with all leadm1416.01416.0110.0FalseNoneNoneFalseNoneFalse155760.00
3046833102982NoneItem MR3/8 (9.52 mm) X 21 Swg (0.8mm) Soft drawn (Insulation 13mm thick) ---- etc., complete with all leadm1475.01475.0110.0FalseNoneNoneFalseNoneFalse162250.00
3046834102982NoneItem MR1/2(12.7 mm) X 21 Swg (0.8 mm) - Soft drawn (Insulation 13mm thick) ---- etc., complete with all leadm1652.01652.0240.0FalseNoneNoneFalseNoneFalse396480.00
3046835102982NoneItem MR5/8 (15.9 mm) X 19 Swg (1 mm) - Soft drawn (Insulation = 13mm thick) ---- etc., complete with all leadm1829.01829.060.0FalseNoneNoneFalseNoneFalse109740.00
3046836102982NoneItem MR7/8( 22.2 mm) X 19 Swg (1 mm) - Hard drawn (Insulation = 19mm thick) ---- etc., complete with all leadm2006.02006.0100.0FalseNoneNoneFalseNoneFalse200600.00
3046837102982NoneItem MR1 1/8 (28.6 mm) X 19 Swg (1 mm) - Hard drawn (Insulation = 19mm thick) ---- etc., complete with all leadm2242.02242.080.0FalseNoneNoneFalseNoneFalse179360.00
3046838102982NoneItem MRSupply, Installation, Testing & Commissioning of Open cell "Class-1" Nitrile rubber Insulation for Duct Acoustics insulation with Ultrafresh Antimicrobial protection as per ASTM G21, ASTM G22, UL-181 and E2180 , Density 140-180Kg / m3, UL94 approved (HBF, HF 1 & HF 2) in accordance to UL 94,1996. Thermal conductivity 0.047 W / MK at 20 Deg C, Air Erosion Resistance test Confirming to ASTM Standard C 1071-05 (section 12.7).  Moisture resistant-joining tapes of 2 inches width with self adhesive to be supplied with the insulation material by the supplier. Use Low Voc Adhesive. (Adhesive VOC level as per LEED requirement) Note - if the adhesive is not self adhiesive type then the glue should be used with the same manufacturer. 15mm Thick ---- etc., complete with all leadSqm1298.01298.0160.0FalseNoneNoneFalseNoneFalse207680.00
3046839102982NoneItem MRSupply, Installation, Testing & Commissioning of Closed cell Class-O Nitrile rubber Insulation with Factroy Laminated Alu-foil with Ultrafresh Antimicrobial protection with both side skin/smooth surface, As per ASTM G21, ASTM G22, UL181 and E2180.  Class O IMO A 653 (16), FM Global, UL 94 EPA  approved,with Density 4060kg m3. Temperature of 50 to 116 Deg C and As per EN12667(DIN 52612). Thermal conductivity of 0.036 W / m K 0 deg C. Water vapour permeability as per EN12086 (DIN 52615) , Moisture Resistance Factor 7000. Aluminum foil tape of 75mm width should be used to seal the joints with self adhesive tape (Black Cotton Tape not acceptable). Use Low Voc Adhesive. (Adhesive VOC level as per LEED requirement) Material shall be FM approved and preferred color shall be Black. Note - if the adhesive is not self adhiesive type then the glue should be used with the same manufacturer. Note: Costing is inclusive of necessary support like cup and washer with scaffolding arrangements to install the underdeck insulation. 25mm Thick (Under Deck Insulation) ---- etc., complete with all leadSqm1062.01062.0950.0FalseNoneNoneFalseNoneFalse1008900.00
3046840102982NoneItem MRSupply, Installation, Testing & Commissioning of Fire damper with opposed blade (Fusible link type). Fire damper as per UL 555, outer shell constructed with 1.6mm thick galvanized steel frame and the blade/Leaf with 1.6mm thick GSS and with necessary flanges for connection. The damper shall be of 90 min fire rating with Fusible Link & spring mechanism the damper shall be held open by a replaceable fusible link rated at 74 deg C.(Area calculation : (L x B) ---- etc., complete with all leadSqm15340.015340.05.0FalseNoneNoneFalseNoneFalse76700.00
3046841102982NoneItem MRSupply, Installation, Testing & Commissioning of Quadrant type Volume controle Damper (VCD). The volume control damper shall be of low leakage type with the outer shell constructed of 1.6mm thick galvanized steel frame and the blade/Leaf with 1.6mm thick GSS and with necessary flanges for connection etc.,(Area calculation : (L x B) ---- etc., complete with all leadSqm9440.09440.07.0FalseNoneNoneFalseNoneFalse66080.00
3046842102982NoneItem MRSupply, Installation, Testing & Commissioning of Back draft damper (BDD). The Back draft damper with the outer shell constructed of 1.6mm thick galvanized steel frame and the blade/Leaf with 1mm thick aluminum and with necessary flanges for connection and as per specifications.(Area calculation : (L x B) ---- etc., complete with all leadSqm10620.010620.01.0FalseNoneNoneFalseNoneFalse10620.00
3046843102982NoneItem MRSupply, Installation, Testing & Commissioning of Butterfly Damper GI Constructed Single Flap with round flange on one side and 10mm grove on other side for fixing of flexible duct with the help of band. 20G GI constructed self lubricated bronze Bushes and 1.6mm flange.250 dia ---- etc., complete with all leadNos2360.02360.020.0FalseNoneNoneFalseNoneFalse47200.00
3046844102982NoneItem MRSupply, Installation, Testing & Commissioning of Extruded Aluminum powder coated Exhaust air Disc valves/grille without volume control dampers for Pantry. a) Note: Colour shall be as per the False ceiling or Architect intent.150 mm Dia ---- etc., complete with all leadNos1475.01475.020.0FalseNoneNoneFalseNoneFalse29500.00
3046845102982NoneItem MRSupply, installation, testing and commissioning of Extruded Al. Powder coated Fresh air / Exhaust air louvers with slimline blade (3 mm nominal thickness) grille height 16 mm, blade pitch 12.5 mm and blade angle 0/15 degree deflection without damper and with end flanges. Note: Colour shall be as per the False ceiling or Architect intent. ---- etc., complete with all leadSqm10620.010620.03.0FalseNoneNoneFalseNoneFalse31860.00
3046846102982NoneItem MRSupply, Installation, Testing and Commissioning of Aluminium Collar Damper of opposed blade type aluminum extruded construction black anodized dampers. (Used in supplay air) ---- etc., complete with all leadSqm7670.07670.02.0FalseNoneNoneFalseNoneFalse15340.00
3046847102982NoneItem MRSupply, Installation, Testing & Commissioning of Condensate CPVC drain piping with insulated with 6mm Nitrile rubber insulation including elbows, connectors, U traps, Y-connections and flexible tubing for all indoor units to the nearest drain points / toilet drain / pantry drain / HVAC shaft available as per approved shop drawings or site conditions and as per directions of the Consultant and Architect. The quote should inclusive of all Hardware necessary to secure the pipes. 40 mm dia ---- etc., complete with all leadm590.0590.085.0FalseNoneNoneFalseNoneFalse50150.00
3046848102982NoneItem MRSupply, Installation, Testing & Commissioning of Condensate CPVC drain piping with insulated with 6mm Nitrile rubber insulation including elbows, connectors, U traps, Y-connections and flexible tubing for all indoor units to the nearest drain points / toilet drain / pantry drain / HVAC shaft available as per approved shop drawings or site conditions and as per directions of the Consultant and Architect. The quote should inclusive of all Hardware necessary to secure the pipes. 32 mm dia ---- etc., complete with all leadm531.0531.030.0FalseNoneNoneFalseNoneFalse15930.00
3046849102982NoneItem MRSupply, Installation, Testing & Commissioning of Condensate CPVC drain piping with insulated with 6mm Nitrile rubber insulation including elbows, connectors, U traps, Y-connections and flexible tubing for all indoor units to the nearest drain points / toilet drain / pantry drain / HVAC shaft available as per approved shop drawings or site conditions and as per directions of the Consultant and Architect. The quote should inclusive of all Hardware necessary to secure the pipes. 25 mm dia ---- etc., complete with all leadm413.0413.0160.0FalseNoneNoneFalseNoneFalse66080.00
3046850102982NoneItem MRSupply, Installation, Testing & Commissioning of Drain Pumps for CHW/VRV/VRF/DX Type Hi-Wall Units and Ceiling Mounted Units. Mini Blanc Pumps (External) for Hi-Wall units. (Max. flow 12L/h & Head is 10Met) ---- etc., complete with all leadNos8850.08850.016.0FalseNoneNoneFalseNoneFalse141600.00
3046851102982NoneItem MRMini Tank Pump (Less then 5.0 TR CSU/FCU) - (Max. flow 35L/h & Head is 15Met) ---- etc., complete with all leadNos10620.010620.03.0FalseNoneNoneFalseNoneFalse31860.00
3046852102982NoneItem MRMax Hi-Flow (Above 5.0 TR CSU/FCU) - (Max. flow 550L/h & Head is 5Met) ---- etc., complete with all leadNos12980.012980.09.0FalseNoneNoneFalseNoneFalse116820.00
3046853102982NoneItem MRSupply, Installation, Testing & Commissioning of Duct type Strip heater (For Customized AHU's) with nessacery electrical wiring and connection. Incoming power supply from respactive Starter panel. (Used in Winter season to achiev the room Temp) Heater bank & Duct befer and after the Heater bank should be panted in RED for 150mm on either side of the Heater bank. 1.5 Kw ---- etc., complete with all leadNos8260.08260.010.0FalseNoneNoneFalseNoneFalse82600.00
3046854102982NoneItem MRSupply, Installation, Testing & Commissioning of Duct type Strip heater (For Customized AHU's) with nessacery electrical wiring and connection. Incoming power supply from respactive Starter panel. (Used in Winter season to achiev the room Temp) Heater bank & Duct befer and after the Heater bank should be panted in RED for 150mm on either side of the Heater bank. 3.0 Kw ---- etc., complete with all leadNos11800.011800.015.0FalseNoneNoneFalseNoneFalse177000.00
3046855102982NoneItem MRSupply, Installation, Testing & Commissioning of Magnehelic Differential Pressure Gages (IP-67 enclosure) to Indicate Positive, Negative or Differential, Accurate within 1%. Note: Pressures must be less than 35 psi.Mounting Orientation:Diaphragm in vertical position. Consult factory for other position orientations. Costing is inclusive of with necessary fittings and Pitot Tube and etc.. AHU/CSU Filter Section ---- etc., complete with all leadNos11210.011210.08.0FalseNoneNoneFalseNoneFalse89680.00
3046856102982NoneItem MRSupply, Installation, Testing & Commissioning of Duct Type Temperature & RH Sensors (IP40 enclosure) (Immersion depth 230 mm) with all mounting accessories to measure the Return Air temperatures. (Temperature range : -0C to 55C & R.H. range 10% to 90%) Note : Used for AHU's, CSU's FCU's & Cassette units. ---- etc., complete with all leadNos10030.010030.08.0FalseNoneNoneFalseNoneFalse80240.00
3046857102982NoneItem MRSupply, Installation, Testing & Commissioning of Room Type Temperature & RH Digital Sensors (Thermostats) with all mounting accessories to measure the critical Room air temperatures. (Temperature range : -20C to 60C & R.H. range 0% to 99%) ---- etc., complete with all leadNos10030.010030.08.0FalseNoneNoneFalseNoneFalse80240.00
3046858102982NoneItem MRSupply, installation, testing and commissioning of Electrical Power & Controle cabling for AC units, Ventilation & Pressurization fans units. Note : a) Costing is inclusive of necessary supports & supporting rods, saddles at 1m interval. b) Electrical Power cabling quantity (Rmt) to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity. c) Actual measurement of Electrical Power cabling quantity (Rmt) should be taken as per site condition only. 3.0 Core x 2.5 Sqmm - For AHU/CSU/Ventilation units units. (Can be used up to 3.7 Kw / 3Phase) Flexible Cross-linked polyethylene (XLPE) insulated Armoured copper cables (FRLS) Control & Power cable to connect HVAC or Electrical starter panel to respective HVAC equipment. ---- etc., complete with all leadm472.0472.0255.0FalseNoneNoneFalseNoneFalse120360.00
17103318720000NoneNoneBuildingsMODULAR OT11919529.52
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3046859102983NoneItem Approved RateProviding and fixing 50 mm thick prefabricated walkable stainless steel panels ceiling The panel should have a composite construction of two skins, one side stainless steel 304 grade 0.8 mm thick and other side sheet is PPGI sheet of 0.6 mm thick. And these two sheets are held together with aluminum ‘w’ section of 48mm x 10.2mm for frame work and inner space between two sheets is filled with Puff insulation with density of 40KG per Cubic meter. The panel size should be 1.20Mts x 3.00 Mtrs. The stainless steel surface should be brush / MAT finish with antiglare property. The false ceiling panels are designed in such way that to fit within each other. There shall be minimum joints. If joints are necessary the panels will be jointed each other by using aluminum ‘H ‘ section 29 mm x 42 mm for interlock system. And all panel joints will be sealed by using compressible food grade silicon sealent to ensure air tight vapor tight construction. The false ceiling shall be walkable with provision of service panel. The false ceiling should be fixed to the concrete slab by using 8mm treaded tension bars with adjustable turn buckles, fastener, nuts, bolts etc., complete to the concrete slab. Coving: Providing corner joint coving for wall to wall used to provide smooth and seamless corner coving buffed aluminium extruded profile R75 ‘C’ cap, L section profile, ‘Z’ section profile. The required size cut outs for fixing of lights and also for any other services shall be made. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift and etc., complete. The works shall be carried out as per the directions of the Engineer in charge. Note: The panel should be free from scratches and dents MODULAR OT area to8 mtr X6 mtr apprxt. Say 50.00 Sqm ---- etc., complete with all leadSqm10354.510354.5100.0FalseNoneNoneFalseNoneFalse1035450.00
3046860102983NoneItem Approved RateProviding and fixing 50 mm thick prefabricated stainless steel wall panels. The panel should have a composite construction of two skins, one side stainless steel 304 grade 0.8 mm thick and other side sheet is PPGI sheet of 0.6 mm thick and these two sheets are held together with aluminum W section size 48mm x 10.2mm for frame work and inner space between two sheets is filled with Puff insulation with density of 40KG per Cubic meter. The panel size should be 1.20Mts x 3.00 Mtrs. The stainless steel surface should be brush / MAT finish with antiglare property. The wall panels are designed in such way that to fit within each other. There shall be minimum joints. If joints are necessary the panels will be jointed each other by using aluminum H section 29 mm x 42 mm for interlock system. And all panel joints will be sealed by using compressible food grade silicon to ensure air tight vapour tight construction. Coving:Providing corner joint coving used to provide smooth and seamless corner coving buffed Aluminium extruded profile R75 ‘C’ cap, L section profile, ‘Z’ section profile. The covings shall be provided wall to wall, wall to ceiling, wall to floor. The required size cut outs for fixing of control panel and switch plate shall be made. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge. Note: The panel should be free from scratches and dents 6 mtr X 3 mtr X2 Nos. =36 Sqmtr 8 mtr X 3 mtr X2 Nos. =48 Sqmtr Say 84.00 Sqm Door area will be detected form wall panel ---- etc., complete with all leadSqm10354.510354.5168.0FalseNoneNoneFalseNoneFalse1739556.00
3046861102983NoneItem Approved RateSupplying and Fixing STAINLESS STEEL DOOR Providing, fabrication and fixing of Stainless steel door with openable shutter of suitable size. The Door frame section of 50mm x 100mm size is made out of 1.2mm thick Stainless steel sheet of 304 grade. The door shutter of 42 to 45 mm thick by using 0.8mm thick stainless sheet of 304 grade for both sides and the surface of the steel should be MAT finish with antiglare property and having composite construction and the space b/w two sheets is filled with Puff insulation with 40 kg/cum density shall be used to ensure air tight and vapour tight construction. Door shall be provided with automatic drop seal at bottom of door, sealed with high quality neoprene sealing gasket in all edges. The doors are provided with vision panel in double toughened glass size 300mm x 300mm,6mm thick. All accessories including heavy duty SS ball bearing butt door hinges, SS 304 grade handlesto 02 sets, heavy duty door closure, SS concealed Tower Bolt, etc are all approved make. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge. Srub Door /Dirty utility Door single leaf 1 mtr X 2.10 mtr Say 2.10 Sqmtr ---- etc., complete with all leadSqm53843.3953843.394.2FalseNoneNoneFalseNoneFalse226142.2380
3046862102983NoneItem Approved RateSupplying and Fixing HERMATICALLY SEALED STAINLESS STEEL SLIDING DOOR Providing, fabrication and fixing of manually operated hermetically sealed stainless steel sliding door of size1500 x 2100mm. The door shutter of 42 to 45 mm thick by using 0.8mm thick stainless sheet of 304 grade for both sides and the surface of the steel should be MAT finish with antiglare property and having composite construction and the space b/w two sheets is filled with Puff insulation with 40 kg/cum density shall be used to ensure air tight and vapour tight construction. The sliding Door runs on Nylon wheel within an Aluminium extrusion high quality rail complete with required accessories. The door track is constructed from an aluminium extrusion, fixed firmly to the wall. Door shall be provided with automatic drop seal at bottom of door, sealed with high quality neoprene sealing gasket in all edges. The doors are provided with vision panel in double toughened glass size 300mm x 300mm,6mm thick. All accessories including SS 304 grade handlesto 02 sets, SS concealed Tower Bolt, etc., Complete are all approved make. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge. ---- etc., complete with all leadSqm96585.3696585.367.0FalseNoneNoneFalseNoneFalse676097.520
3046863102983NoneItem Approved RateAntistatic Epoxy Flooring : Providing and laying 4mm thick antitostatic, antitofungal and antitobacterial epoxy flooring after preparing the floor surface by removing all loose particles, dirt by using coir brush and vacuum cleaner. Applying one coat of Moisture barrier primer and then applying selftoleveling 2mm thick moisture barrier layer to capture the moisture of the existing flooring. Then the anti static grid is laid with conductive granules and copper strips. Then apply one coat of epoxy based primer and allow for dry 6to 8 hours. Then apply epoxy putty and allow for dry 6 8 hours. And then apply 2 mm thick selftoleveling epoxy flooring of approved make, colour and shade. The Epoxy flooring should be impact resistance, chemical resistance including abrasion and fumigation with R75mm coving wall to wall, wall to flooring etc., The cost includes cost of material, labour, transportation etc., complete. The works shall be carried out as per the directions of the Engineer in charge. ---- etc., complete with all leadSqm3835.03835.0108.0FalseNoneNoneFalseNoneFalse414180.00
3046864102983NoneItem Approved RateSupplying and Fixingof 2'x2' LED recessed luminarie with…. Watts system wattage. Housing shall be with pressure die cast aluminium alloy with corrosion proof resistant polyester powder coated. Driver operates with voltage range from 100v to 270V 50/60 Hz with short circuit, overload and mistowring protection. Lumen maintenance of 70percent at 50000 Hrs. injection moulded poly carbonate diffuser for better mechanical stability, light transmission and avoid pot hole effect. Junction temperature shall be 70 degree Celsius. Driver is on constant current driver at 0.06A with PF 0.9, line voltage at 50Hz, driver efficiency 85percent and THD15percent. LED Efficiency 130 Im/W and Fixture Efficiency 75lm/w with CRI 75 with injection moulded Polycarbonate lens with 8mm depth. 5 years Warranty against any manufacturing defect working under standard electrical condition.] ---- etc., complete with all leadEach9725.569725.5616.0FalseNoneNoneFalseNoneFalse155608.960
3046865102983NoneItem Approved RateSupplying and Fixing LED to XtoRay Viewing Screen :XtoRAY VIEWING SCREEN: to Two Plate XtoRay View Screen with flicker free illumination having imported LED system for uniform illumination and operated by Xtoray film. The system having electrical safety codes for high and Low voltage system. The X ray viewing screen shall be concealed with wall panel. ---- etc., complete with all leadEach33040.033040.02.0FalseNoneNoneFalseNoneFalse66080.00
3046866102983NoneItem Approved RateSupplying and Fixing Magnetic Writing List Board:Magnetic Writing Board of size 940 x 640 x 50 mm comprises of a flush mounted, 1.50 mm thick, white laminate board, bonded to a 10 mm high density fibre board sheet for additional rigidity. Magnetic Writing List Board shall be concealed with wall panel. ---- etc., complete with all leadEach6903.06903.02.0FalseNoneNoneFalseNoneFalse13806.00
3046867102983NoneItem Approved RatePlenum Laminar Flow : Supply and installation of Stainless steel 304 grade Plenum LAMINAR FLOWto Plan air Ceiling mounted system with unidirectional airflow,Air flow velocity of 25 to 35 FPM Plenum unit, Holding structure and Top plenum are conforming to DIN 4799 / EU14 Mini pleate HEPA filter standards for the air distribution system complete with provision for 6 Nos. Size 1220mmX610mmX90mm thick HEPA Filters efficiency 99.97percent down to 0.3 micron , 4000 cfm. The Plenum size is 1800 x 2400mm. The Diffuser is made out of SS 304 Grade material for laminar of filtered air. The complete unit will have factory prepared fine sealing system. It will be perfectly seamless. It will be made out of SS 304 Sheet of required thickness With perforated SS 304 sheet with etc., complete. ---- etc., complete with all leadEach312700.0312700.02.0FalseNoneNoneFalseNoneFalse625400.00
3046868102983NoneItem Approved RateSupplying and Fixing STAINLESS STEEL STORAGE UNIT:Providing and supplying Storage Unit of size 800x1900x350 mm has made of 0.8.mm thick SS304 grade sheet. The exterior openable glass doors shall be made by using 6mm thick toughened glass with lockable and magnetic pushtobutton for easy opening. Removable toughened glass shelves of thickness 6 mm will be provided with the storage units. ---- etc., complete with all leadEach70800.070800.02.0FalseNoneNoneFalseNoneFalse141600.00
3046869102983NoneItem Approved RateSupplying and Fixing PASS/HATCH BOX:Providing and fixing Hatch box for modular OT in stainless steel SS 304, SS Handles, SS Hinges, View window, Door close/open indication, Electromagnetic door interlocking system based on Microcontroller electronic system for disposal of dirty linen/waste to nontosterile store.Size 600mm x 600mm x 600mm with double door inter lock and consisiting of UV lamp, UV lamp on for both door closed, UV lamp off for any door open, CF lamp on any door is open CF lamp off both door closed including cost of conceted accessories. ---- etc., complete with all leadEach76700.076700.02.0FalseNoneNoneFalseNoneFalse153400.00
3046870102983NoneItem Approved RateSupplying and Fixing OT control Panel 6 Tile : Supply and installation of 6 tile OT control panel with distribution box, control panel will be mounted flush in the theatre wall, comprising of the following 1. Medical gas card 2. Laminar Air flow controls Temperature and humidity indicators, filter status, temperature and humidity control. 3. Digital elapsed timer 4. Hand free phone 5. Digital day timer clock 6. Lighting control panel ---- etc., complete with all leadEach129800.0129800.02.0FalseNoneNoneFalseNoneFalse259600.00
3046871102983NoneItem Approved RateProviding and fixing SS304 grade return air grill. The cut out for return air grill size in panel is 600mmX450mm. The cost includes cost of material, labour charges for fixing etc complete. ---- etc., complete with all leadEach4130.04130.08.0FalseNoneNoneFalseNoneFalse33040.00
3046872102983NoneItem Approved RateSUPPLY ERECTION TESTING and COMISSIONING of Return air riser made out of SS 304 grade with 18 SWG in the clean room area of 1000 CFM and provision for return air collar damper anf grill with all concted accessories. ---- etc., complete with all leadEach21240.021240.08.0FalseNoneNoneFalseNoneFalse169920.00
3046873102983NoneItem Approved RateSupplying and Fixing Providing and making trap door of size 600 x 600mm in the ceiling panel by cutting. The required frame work shall be made by using Aluminium sections. The cost includes cost of material, labour charges for fixing etc complete. ---- etc., complete with all leadEach7375.07375.02.0FalseNoneNoneFalseNoneFalse14750.00
3046874102983NoneItem Approved RateAHU's RECYCLE SYSTEM FOR OT AREA AS PER NABH NORMS SUPPLY ERECTION TESTING and COMISSIONING Air handling units of GSS powder coated sheet metal cabinet type Double skin Recirculatory type 40to45 mm thick,Thermal break,modular construction.Air handling units shall be complete with Backward curved blower having capacity of 3500 t0 4000 cfm Minimum 25 to 35 ACPH with 125 mm capacity, 3.75kw TEFC motor,fan motor drive filter section with 10 microns pre filter,3 microns fine filters, DX coil 6 row section of copper coil with aluminium fins,Mist eleminator, inlet and outlet volume control dampers and bypass dampers with access doors and accessories including 10percent Fresh air with module with console type and grill, 20 Microns Fresh air filter. 10percent Bleed module with hepa filter,damper and grille, View glass, View lamp, limit switch for door and Pressure port for filter sections and provision to fix pressure port to measure the pressure drop across the filter, EFF1 Motor coil should be 5. 5 TR x 2 circute with all concted accessories. ---- etc., complete with all leadNo597788.0597788.02.0FalseNoneNoneFalseNoneFalse1195576.00
3046875102983NoneItem Approved RateAIR COOLED CONDENSER UNIT and COPPER PIPING SUPPLY ERECTION TESTING and COMISSIONING 5.5 TR Air cooled out door condensing units comprising of semi tohermetic / hermetic reciprocating/scrool compressors with matching air cooled condenser suitable for 3500 to 4000 CFM AHU provided with necessary controls.like Thermostart , Draier with MS painted stand ---- etc., complete with all leadNo146320.0146320.04.0FalseNoneNoneFalseNoneFalse585280.00
3046876102983NoneItem Approved RateGRILLE and DAMPER SUPPLY ERECTION TESTING and COMISSIONING Collar damper made out of Al. with powder coated as per return air openinig size ---- etc., complete with all leadSqm10384.010384.04.0FalseNoneNoneFalseNoneFalse41536.00
3046877102983NoneItem Approved RateSUPPLY ERECTION TESTING and COMISSIONING Aluminium Volume control dampers manual operated, Only for hepa module, unit mouth and branch Ducts ---- etc., complete with all leadSqm13924.013924.04.0FalseNoneNoneFalseNoneFalse55696.00
3046878102983NoneItem Approved RateSUPPLY ERECTION TESTING and COMISSIONING Fire Dampers with Fusible Links rated for 72C for AHU mouth, with fire damper actuator with inter link with AHU controll panel in case of fire AHU motor should stop. ---- etc., complete with all leadNo6254.06254.02.0FalseNoneNoneFalseNoneFalse12508.00
3046879102983NoneItem Approved RateSUPPLY ERECTION TESTING and COMISSIONING Fire retardant flexible connections for AHU supply and return air mouth ---- etc., complete with all leadNo5546.05546.04.0FalseNoneNoneFalseNoneFalse22184.00
3046880102983NoneItem Approved RateDUCTING and INSULATION SUPPLY ERECTION TESTING and COMISSIONING Al. ducting including the supports,selicon sealent with painted MS angle flanges.22 guage ---- etc., complete with all leadSqm2006.02006.0320.0FalseNoneNoneFalseNoneFalse641920.00
3046881102983NoneItem Approved RateSUPPLY ERECTION TESTING and COMISSIONING Supply and return air duct Insulation with factory laminated Al. foil class 'O' grade 13 mm thk for return air duct ---- etc., complete with all leadSqm920.4920.4160.0FalseNoneNoneFalseNoneFalse147264.00
3046882102983NoneItem Approved RateSUPPLY ERECTION TESTING and COMISSIONING Supply and return air duct Insulation with factory laminated Al. foil class 'O' grade 19 mm thk for supply air duct ---- etc., complete with all leadSqm1097.391097.39180.0FalseNoneNoneFalseNoneFalse197530.20
3046883102983NoneItem Approved RatePolishield covering with two coats paint for exposed duct ---- etc., complete with all leadSqm1038.391038.39140.0FalseNoneNoneFalseNoneFalse145374.60
3046884102983NoneItem Approved RateSUPPLY and Fixing 300 dia Insulated flexible connection for grille module and return air raiser ---- etc., complete with all leadm979.4979.440.0FalseNoneNoneFalseNoneFalse39176.00
3046885102983NoneItem Approved Rate25 mm PVC dia drain piping with supports for AHUs ---- etc., complete with all leadm625.4625.4100.0FalseNoneNoneFalseNoneFalse62540.00
3046886102983NoneItem Approved RateELECTRICAL and CONTROLLS: SUPPLY ERECTION TESTING and COMISSIONING Ele.controll panel inter lock with AHUs and 5.5 TR 2 nos condenser unit with TEMP. and RH Controller For AHU ---- etc., complete with all leadSet12272.012272.02.0FalseNoneNoneFalseNoneFalse24544.00
3046887102983NoneItem Approved RateSUPPLY ERECTION TESTING and COMISSIONING 4 Kw Ele. Heater with RH controller to controll humidity of 50 to 60percent ---- etc., complete with all leadSet66788.066788.02.0FalseNoneNoneFalseNoneFalse133576.00
3046888102983NoneItem Approved RateSupplying and drawing flexble multicore cable manufactured with electroytic grade copper with flexible copper conductor confirming to table 3 class 5 of IS:8130to1984 and PVC insulation and sheathed suitable for working voltage upto 1100 Volts as per ISto694:1990 and confirming to GTP 4C X 6 Sqmm ---- etc., complete with all leadm218.29218.29120.0FalseNoneNoneFalseNoneFalse26194.80
3046889102983NoneItem Approved RateSupplying and drawing flexble multicore cable manufactured with electroytic grade copper with flexible copper conductor confirming to table 3 class 5 of IS:8130to1984 and PVC insulation and sheathed suitable for working voltage upto 1100 Volts as per ISto694:1990 and confirming to GTP 4C X 4 Sqmm ---- etc., complete with all leadm177.0177.0120.0FalseNoneNoneFalseNoneFalse21240.00
3046890102983NoneItem Approved RateSupplying and drawing flexble multicore cable manufactured with electroytic grade copper with flexible copper conductor confirming to table 3 class 5 of IS:8130to1984 and PVC insulation and sheathed suitable for working voltage upto 1100 Volts as per ISto694:1990 and confirming to GTP 4C X 2.5 Sqmm ---- etc., complete with all leadm123.89123.8960.0FalseNoneNoneFalseNoneFalse7433.40
3046891102983NoneItem Approved RateSupplying and drawing flexble multicore cable manufactured with electroytic grade copper with flexible copper conductor confirming to table 3 class 5 of IS:8130to1984 and PVC insulation and sheathed suitable for working voltage upto 1100 Volts as per ISto694:1990 and confirming to GTP 8C X 2.5 Sqmm S.R. ---- etc., complete with all leadm348.09348.0960.0FalseNoneNoneFalseNoneFalse20885.40
3046892102983NoneItem Approved RateSupplying and drawing flexble multicore cable manufactured with electroytic grade copper with flexible copper conductor confirming to table 3 class 5 of IS:8130to1984 and PVC insulation and sheathed suitable for working voltage upto 1100 Volts as per ISto694:1990 and confirming to GTP 4C X 10 Sqmm ---- etc., complete with all leadm348.09348.0960.0FalseNoneNoneFalseNoneFalse20885.40
3046893102983NoneItem Approved RateSUPPLY and Fixing Cable trey 300 width x 50 ht perforated P. No.63 Item No.7.19.2 ---- etc., complete with all leadm645.45645.4560.0FalseNoneNoneFalseNoneFalse38727.00
3046894102983NoneItem Approved RatePlate COpper Earthing strip 24 x 3 mm connected to existing earthing P.55 Item No.7.3.6 ---- etc., complete with all leadm617.14617.14100.0FalseNoneNoneFalseNoneFalse61714.00
3046895102983NoneItem Approved RateSUPPLY and FIXING DP Gauge range 0 to 6 mm wg for OT room to monitoring positive pressure ---- etc., complete with all leadNos10089.010089.02.0FalseNoneNoneFalseNoneFalse20178.00
3046896102983NoneItem Approved RateDSUPPLY and FIXING DP Gauge range 0 to 50 mm wg for AHU and EAU pre and fine filter section to monitoring pressure drop in the filters ---- etc., complete with all leadNos9735.09735.04.0FalseNoneNoneFalseNoneFalse38940.00
3046897102983NoneItem Approved RateSupplying and Fixing Single Arm Rotating OT Pendant: Single ARM 320 Deg Rotating Anesthesia Pendant Complete with Electrical Outlets 8 Nos, Data Points 1 Nos and Medical Gas Outlets 7 Nos, 1 Monitor Tray, 2 Nos. Shelfs, 2 Nos I V Stand Note: 2 SET of DOCUMENTS and VALIDATION AT REST AS PER ISOto14644 and NABH standard to be submitted, Design Qualification, Installation Qualification, Operational Qualification, Performance Qualification Air velocity test, Air changes test, Air qty.check test, Temp. and RH test, DOP test for Hepa filter, Partical count test Class 100, ISO to 5in the termial , Air flow pattern test, Recovery test, Majot materil test certificates ---- etc., complete with all leadNos194700.0194700.02.0FalseNoneNoneFalseNoneFalse389400.00
3046898102983NoneItem Approved RateSupply , installation, testing and commissioning Double arm moveable pendant for surgeon with connected accessories. The Pendants shall comply with NFPA 99C/HTM 02to01/DIN/EN/ISO 7396to1 as amended up to the last date of receipt of tenders. The support arms shall be extremely robust and revolve on high quality bearings, so that the pendant head glides smoothly and quickly to any desired position. Double moveable arms any combination with total coverage of min 1800 mm and minimum 330 Each arm shall have ability of horizontal movement. Vertical movement shall be motorized and the arm height shall remain at a height greater than 6.5 feet above floor level. Weight carrying capacity of the arm shall not be less than 180 kg. It shall have electromagnetic/pneumatic brakes. Each arm shall be capable of minimum 330 of rotation, which can be easily adjusted to suit the desired mode of operation. The pendant shall be European CE Certified with 4 digit notified body number/US FDA/ETL/UL/BIS certified/listed under medical devices directive. The Pendant Service Heads shall be modular with minimum 800mm head.The heads shall be capable of accepting a range of shelves, infusion poles, electrical switch/sockers, gas outlets and other required accessories. The Pendant Heads shall support the range of Physiological Monitor Mounting Solutions. The Pendant Service Heads shall be supplied with medical gas terminal units and 5A/15A or 6A/16 A hybrid sockets. Pendant shall be supplied with outlets and probes as mentioned below. Oxygen Outlets to2 nos , Medical Air Outlets 4 bar to1 no,Vacuum Outlets to2 nos ,Air7bar outletsto01 no, CO2 outletsto01 nos, Electrical Socketsto10 no, Adjustable shelf with two rails one on each side to3 no, Data socket RJto45 to2 nos, IV Fluid Pole with 2 hooks to1 no, Pole shall be capable of stacking 4 syringe pumps, Nitrous oxide outletsto1 no. Pendent shall provide cuttoouts for patch panel in integrated OTs only for integrated OTs. Surgeon pendant shall have NIST connection for all gases to conncet the MGPLS system. ---- etc., complete with all leadNos430700.0430700.02.0FalseNoneNoneFalseNoneFalse861400.00
3046899102983NoneItem Approved RateScrub Station MOT SCRUB STATION minimum size 1500 mm supply , installation and commissioning of compact surgical scrub sink shall be designed for use in OT area for pretoprocedural scrub. Double sink combination shall be provided. Fabricated from heavy gauge type 304 stainless steel minimum thicknes 1.5 mm and shall be of seamless welded construction, polished to a satin finish.With a front access panel which shall be easily removable for access to the water controlled valve, waste connections, stoppers and strainers. Hands free operation shall include infratored sensors with programmable adjustment. .Thermostatic mixing, valve control shall be located behind the access panel and it shall maintain constant water temperature.Timing shall be adjustable to meet individual application requiements.built in with timer setting from 1 to 10 micIt shall be provided with infrared sensors, thermostatic control taps with fail safe temprerature controls. All units shall have reduced antitosplash fronts.Knee/foot operated switch shall be provided additionally with all connected accessories. ---- etc., complete with all leadNos278480.0278480.02.0FalseNoneNoneFalseNoneFalse556960.00
3046900102983NoneItem Approved RateSupply , installation, testing and commissioning OT surgical Lighting system with connected accessroies MOT surgical lighting system shall provide an ideal combination of brightness, manoeuvrability and shadow resolution without sacrificing colour and accuracy through a consistent LED technology. Such lighting system shall have the following technical specifications: a Number of light heads : Two b Rotation system : 360 c Colour temperature range : 3800K to 5000 K 10percenttovariable colour temperature. d CRI : 93 Ra. e LED's : Low temp . 3 Colours combination. f LED bulb life : 50,000 hrs. g Field size diameter : 20 to 28 cm 10percent h Working range : 750 to 1100 mm 10percent i Focus : Adjustable 100mmto250mm. j Illumination leve l: minimum 160,000 lux both for major dome and minor dome separately. k Controls : control panel two:one on the wall and other on dome/ digital with wireless remote. l Power supply : 220 V/ 50Hz AC. ---- etc., complete with all leadNos413118.0413118.02.0FalseNoneNoneFalseNoneFalse826236.00
17103318720000NoneNoneBuildingsLIFT (20 PASSENGER CUM BED LIFT 2 NOS.7145337.74
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3046901102984NoneItem 14.4.6Design, supplying, erecting testing and commissioning of - 20Passenger/ Bed-cum-passenger hospital lift(3 stops/3 Opening) with speed of 1mtr per second, variable voltage variable frequency drive, with or without machine room for the available well size, operating at 415 V 3 phase 50 cycles AC supply, powder coated / Stainless Steel car entrance doors enclosures with suitable colour vinyl flooring, LED car illumination, emergency light, intercom and fan as desired by the user, central opening / side opening door with or without attendant operation, 7 segment display buttons, call register indicator, fireman drive, SS handrails inside car, full length infrared curtain in car door, automatic rescue device with batteries, voice announcing in regional/ international languages, Braille buttons with one year warranty and maintenance with necessary scaffolding and minor civil works like fixing of guide rail, counter weight etc.,The total product and services shall adhere to IS 14665/2016 ( with latest amendments) part/section 1 to 5 with regards to general guidelines of fire safety rated doors, MRLL beams, pressure switch, manual change over for doors during emergency, ARD of 10 times with sufficient battery back up and standard dimensions of chair car and door openings for all sizes and capacities of lifts including fitness certificate and duly observing all other safety norms prescribed and adhere to CPWD specifications, PCB Norms, National Electricity Code (NEC), NBC-2016, IEC and Karnataka State Lifts, Escalators and Passengers Conveyers Act 2012 and Rules 2014. The Supplier shall be registered in Government Electrical Inspectorate in the State of Karnataka. ---- etc., complete with all leadEach3572668.873572668.872.0FalseNoneNoneFalseNoneFalse7145337.740
17103318720000NoneNoneBuildingsUPS1631940.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3046902102985NoneLeast Quotation RateSupply, Installation Testing and commissioning of double convertsion, DSP Based, True on line 2 x30KVA Modular type UPS system with 415V +/- 15% V,50Hz,3Ph Input & 415V+/-1%, 50 Hz ,3Ph Output, With Output 0.9 PF, working on 16 Bit microprocessor Architecture,Isolation transformers, RS 232 ports, monitoring software , O/L, SC. protections & self diagnostic features, LCD Display Panel for Functions & all parameters, complying with IEC standards. Convertors, Invertors & Battery Charger shall utilize PWM technology with IGBT. Battery Back up time of 15 minutes back up on 60kva load with required VRLA SMF individual Battery bank System(65AH-32 Nos each Battery Bank) housed in suitable Cabinet /Rack, Static ByPass, complete with Internal wiring & all accessories to be provided. The System shall have in-built P.F.correction & shall ensure THD as per latest International standards. The efficiency of UPS shall be 96% or more. ---- etc., complete with all leadEach1631940.01631940.01.0FalseNoneNoneFalseNoneFalse1631940.00
17103318720000NoneNoneBuildingsTELEPHONE NETWORKING CCTV SYSTEM AND NURSE CALL SYSTEM4646865.58
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3046903102986NoneItem 3.6.13RJ45/ I.O. outlet Cat 6 ---- etc., complete with all leadEach417.54417.54132.0FalseNoneNoneFalseNoneFalse55115.280
3046904102986NoneItem 3.6.12Telephone socket ---- etc., complete with all leadEach193.28193.2850.0FalseNoneNoneFalseNoneFalse9664.00
3046905102986NoneItem 8.1Supplying and drawing UTP-CAT 6E LAN cable. ---- etc., complete with all leadm47.0847.082500.0FalseNoneNoneFalseNoneFalse117700.00
3046906102986NoneItem 8.10.1Supplying & Fixing of I/O Socket with back box Single I/O ---- etc., complete with all leadEach607.11607.1150.0FalseNoneNoneFalseNoneFalse30355.50
3046907102986NoneItem 8.4.6Supplying & Fixing of switch mounting rack with power manager & Cable manager as per standard specification 24U with 650mm depth ---- etc., complete with all leadEach38887.2538887.252.0FalseNoneNoneFalseNoneFalse77774.50
3046908102986NoneItem 8.9.11Supplying fixing of Network Switches. 16 port 10/100/1000 Switch ---- etc., complete with all leadEach7979.167979.161.0FalseNoneNoneFalseNoneFalse7979.160
3046909102986NoneItem 8.9.10Supplying fixing of Network Switches. 24 port 10/100/1000 Switch ---- etc., complete with all leadEach9187.199187.191.0FalseNoneNoneFalseNoneFalse9187.190
3046910102986NoneItem 8.11.1Supplying & fixing of ..mtrs. Cat 6Patch Cable. 2Mtr ---- etc., complete with all leadEach318.42318.4250.0FalseNoneNoneFalseNoneFalse15921.00
3046911102986NoneItem 8.12.3Supplying & Fixing of Patch panel for Lan Cabling. 16 Port 10/100 patch panel ---- etc., complete with all leadEach3778.953778.951.0FalseNoneNoneFalseNoneFalse3778.950
3046912102986NoneItem 8.12.5Supplying & Fixing of Patch panel for Lan Cabling. 24 Port 10/100 patch panel ---- etc., complete with all leadEach9788.19788.12.0FalseNoneNoneFalseNoneFalse19576.20
3046913102986NoneItem 8.2.2Supplying and drawing PVC flexible 2 pair telepone unarmoured tinned copper cable. ---- etc., complete with all leadm26.0226.022000.0FalseNoneNoneFalseNoneFalse52040.00
3046914102986NoneItem 8.2.4Supplying and drawing PVC flexible 4 pair telepone unarmoured tinned copper cable. ---- etc., complete with all leadm43.3743.37200.0FalseNoneNoneFalseNoneFalse8674.00
3046915102986NoneItem 8.13.1Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination. 10 Pair ---- etc., complete with all leadEach427.46427.464.0FalseNoneNoneFalseNoneFalse1709.840
3046916102986NoneItem 8.13.2Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination. 20 Pair ---- etc., complete with all leadEach474.54474.543.0FalseNoneNoneFalseNoneFalse1423.620
3046917102986NoneItem 8.13.4Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination. 50 Pair ---- etc., complete with all leadEach781.81781.812.0FalseNoneNoneFalseNoneFalse1563.620
3046918102986NoneItem Least Quotation RateSupply,laying & Termination of Telephone Wires/ Cables as per DOT spcn,with solid annealed Cu Conductor of 0.5mm thick, High Density Polyethylene insulated,Twisted pair,unarmoured ,with outer sheath of low density Polyetylene - 10 pair 0.5mm unarmoured telephone cable ---- etc., complete with all leadm179.36179.36400.0FalseNoneNoneFalseNoneFalse71744.00
3046919102986NoneItem Least Quotation RateSupply,laying & Termination of Telephone Wires/ Cables as per DOT spcn,with solid annealed Cu Conductor of 0.5mm thick, High Density Polyethylene insulated,Twisted pair,unarmoured ,with outer sheath of low density Polyetylene - 30 pair 0.5mm unarmoured telephone cable ---- etc., complete with all leadm230.1230.1200.0FalseNoneNoneFalseNoneFalse46020.00
3046920102986NoneItem Least Quotation RateEPABX:- Supply,Installation,Testing & Commissioning of micro-processor based, state of the Art, Telephone PBX System , IP READY,based on Linux/GRUB compliant, integrated Software for multiTasking for Hospitality Services including Billing ,comprising of items as below but not limited to them. Expanadable upto 50 Ports Providing PRI cards for Trunk lines / for tie line with reqd.software 16Analog Trunk Lines 4 Digital Extensions 20 Analogue Extensions( Expandable up to 50) In-Built Voicemail ( 4 Port & 80 Min) LAN Connectivity Embedded WELCOME MESSAGE Least Cost Routing Personal Assistant Music on Hold . ---- etc., complete with all leadNos295000.0295000.01.0FalseNoneNoneFalseNoneFalse295000.00
3046921102986NoneItem Least Quotation RateTELEPHONES Analog push button telephone with Caller ID, flash andradial ---- etc., complete with all leadNos2124.02124.050.0FalseNoneNoneFalseNoneFalse106200.00
3046922102986NoneItem Least Quotation Rate42 U Network cum Server Rack Assembly, Floor Mounting, made of Aluminium Channels equivalent to Euro Rack System with side and rear panels made of Powder Coated sheet steel, front transparent persplex door and with rails, rollers with fans will be provided at the top for ventilation. ---- etc., complete with all leadNos47200.047200.02.0FalseNoneNoneFalseNoneFalse94400.00
3046923102986NoneItem 1.2.2..Supplying heavy gauge PVC conduit pipe 25mm dia 2mm thick thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) ---- etc., complete with all leadm96.6496.642000.0FalseNoneNoneFalseNoneFalse193280.00
3046924102986NoneItem 3.6.11TV socket ---- etc., complete with all leadEach193.28193.285.0FalseNoneNoneFalseNoneFalse966.40
3046925102986NoneItem Least Quotation RateThe Scope of work is Supply,istallation, Testing for T.V. System with following Items & components in Rooms & other Specific Areas. It also covers co-ordination with T.V service provider for completeness & usage of the Items /components erected by Vendor.Booster amplifier. ---- etc., complete with all leadEach3540.03540.04.0FalseNoneNoneFalseNoneFalse14160.00
3046926102986NoneItem Least Quotation RateThe Scope of work is Supply,istallation, Testing for T.V. System with following Items & components in Rooms & other Specific Areas. It also covers co-ordination with T.V service provider for completeness & usage of the Items /components erected by Vendor. 3 way splitter. ---- etc., complete with all leadEach236.0236.08.0FalseNoneNoneFalseNoneFalse1888.00
3046927102986NoneItem 8.3Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6. ---- etc., complete with all leadm54.5254.52300.0FalseNoneNoneFalseNoneFalse16356.00
3046928102986NoneItem Least Quotation RateIP DOME CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.82 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),30M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets. ---- etc., complete with all leadEach23836.023836.014.0FalseNoneNoneFalseNoneFalse333704.00
3046929102986NoneItem Least Quotation RateIP BULLET CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8*2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),60M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets. ---- etc., complete with all leadEach25606.025606.04.0FalseNoneNoneFalseNoneFalse102424.00
3046930102986NoneItem Least Quotation RateSupplying, installation, testing and commissioning of SITC of complete 32 channel 4K embedded network video recorder,up to 12MP(4K) resolution live view,preview,and play back,full POE Support (for up to 16 channels),internal storage supports 8HDDs expandable up to 64TB (8TB each),operating temperatures(-10 degree C) and (55 degree C),UL,CE,FCC. ---- etc., complete with all leadEach271400.0271400.02.0FalseNoneNoneFalseNoneFalse542800.00
3046931102986NoneItem Least Quotation RateSupply and Installation of 4 TB Survalance Hard Disk The rate shall include all mounting accessories complete as required ---- etc., complete with all leadEach17110.017110.08.0FalseNoneNoneFalseNoneFalse136880.00
3046932102986NoneItem Least Quotation RateSupply and Installation of 24 Port L2 Managed Poe Switch The rate shall include all mounting accessories complete as required ---- etc., complete with all leadEach33630.033630.02.0FalseNoneNoneFalseNoneFalse67260.00
3046933102986NoneItem Least Quotation RateSupply and Installation of 43"LED Monitor The rate shall include all mounting accessories complete as required ---- etc., complete with all leadEach70800.070800.04.0FalseNoneNoneFalseNoneFalse283200.00
3046934102986NoneItem 8.1Supplying and drawing UTP-CAT 6E LAN cable ---- etc., complete with all leadm47.0847.08600.0FalseNoneNoneFalseNoneFalse28248.00
3046935102986NoneItem 1.2.2Supplying heavy gauge PVC Consealed conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick ---- etc., complete with all leadm96.6496.64350.0FalseNoneNoneFalseNoneFalse33824.00
3046936102986NoneItem 8.12.2Supplying & Fixing of Patch panel for LAN cabling .24 Port 10/100 patch panel ---- etc., complete with all leadEach5079.95079.94.0FalseNoneNoneFalseNoneFalse20319.60
3046937102986NoneItem 8.4.4Supplying & Fixing of switch mounting rack with power manager & Cable manager 12U with 450mm depth ---- etc., complete with all leadEach10501.7610501.762.0FalseNoneNoneFalseNoneFalse21003.520
3046938102986NoneItem 8.4.6Supplying & Fixing of switch mounting rack with power manager & Cable manager 24U with 650mm depth ---- etc., complete with all leadEach38887.2538887.252.0FalseNoneNoneFalseNoneFalse77774.50
3046939102986NoneItem Least Quotation RateSupply and Installation of Micro controller based Indication wall Mount panel With the following facilities: 3 Digit room display Reset switch Relay logic switch Voice recording module Mute switch Battery management circuit Wall mounting type enclosure RS 485 networking chord The rate shall include all mounting accessories complete as required ---- etc., complete with all leadNos130328.64130328.6410.0FalseNoneNoneFalseNoneFalse1303286.40
3046940102986NoneItem Least Quotation RateSupply and Installation of Call unit with Switches like Membrane Type Call Switches with bell indicator LED Indicator Membrane Type Reset Switch Compatible for hand held call unit Mounted On Standard electrical 2 module plate near the Bed ---- etc., complete with all leadNos4121.54121.575.0FalseNoneNoneFalseNoneFalse309112.50
3046941102986NoneItem 8.1Supplying and drawing UTP-CAT 6E LAN cable ---- etc., complete with all leadm47.0847.081000.0FalseNoneNoneFalseNoneFalse47080.00
3046942102986NoneItem 1.2.2Supplying heavy gauge PVC Consealed conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick ---- etc., complete with all leadm96.6496.64800.0FalseNoneNoneFalseNoneFalse77312.00
3046943102986NoneItem 8.12.2Supplying & Fixing of Patch panel for LAN cabling .24 Port 10/100 patch panel ---- etc., complete with all leadEach5079.95079.92.0FalseNoneNoneFalseNoneFalse10159.80
17103318720000NoneNoneBuildingsEXTERNAL ELECTRICAL WORKS AND DG SET4999648.03
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3046944102987NoneItem 1.01Supply RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete with all leadSet8767.168767.162.0FalseNoneNoneFalseNoneFalse17534.320
3046945102987NoneItem 2.02Erection of RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete with all leadSet1379.011379.012.0FalseNoneNoneFalseNoneFalse2758.020
3046946102987NoneItem 6.05Supply of 11 kV, 45 KN Polymeric Insulator ---- etc., complete with all leadNos107.79107.7912.0FalseNoneNoneFalseNoneFalse1293.480
3046947102987NoneItem 13.12Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., complete with all leadNos59.4759.4712.0FalseNoneNoneFalseNoneFalse713.640
3046948102987NoneItem 2.16Supply of Spiral Earth Electrode ---- etc., complete with all leadNos296.12296.124.0FalseNoneNoneFalseNoneFalse1184.480
3046949102987NoneItem 2.16Erection of Spiral Earth Electrode ---- etc., complete with all leadNos115.23115.234.0FalseNoneNoneFalseNoneFalse460.920
3046950102987NoneItem 68.17Supply and fixing of Caution/Danger Board ---- etc., complete with all leadNos185.85185.852.0FalseNoneNoneFalseNoneFalse371.70
3046951102987NoneItem 4.02Supply of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete with all leadEach110.27110.274.0FalseNoneNoneFalseNoneFalse441.080
3046952102987NoneItem 5.09Erection of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete with all leadEach52.0452.044.0FalseNoneNoneFalseNoneFalse208.160
3046953102987NoneItem 24.05Supply and fixing of 11 kV, 400 Amps Double Break GOS ---- etc., complete with all leadSet26341.1426341.142.0FalseNoneNoneFalseNoneFalse52682.280
3046954102987NoneItem 24.07Supply and fixing of H-Frame for mounting GOS ---- etc., complete with all leadNos7521.977521.972.0FalseNoneNoneFalseNoneFalse15043.940
3046955102987NoneItem 25.01Supply of DOLO Cut Out Set/3 Nos ---- etc., complete with all leadSet7279.137279.132.0FalseNoneNoneFalseNoneFalse14558.260
3046956102987NoneItem 13.01Erection of DOLO Cut Out Set/3 Nos ---- etc., complete with all leadSet293.64293.642.0FalseNoneNoneFalseNoneFalse587.280
3046957102987NoneItem 19.01Supply of 9 kV, 5 kA Lightning Arrester Metal Oxide Ceramic type with GROUND DISCONNECTOR (Dwg No. BESCOM/GM/QS&S/26 Dtd 24.10.2007) ---- etc., complete with all leadNos1139.881139.882.0FalseNoneNoneFalseNoneFalse2279.760
3046958102987NoneItem 13.06Installation of Lightning arreste r Set (3 Nos) ---- etc., complete with all leadSet147.44147.442.0FalseNoneNoneFalseNoneFalse294.880
3046959102987NoneItem 1.01Supply RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete with all leadSet8767.168767.166.0FalseNoneNoneFalseNoneFalse52602.960
3046960102987NoneItem 2.02Erection of RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete with all leadSet1379.011379.016.0FalseNoneNoneFalseNoneFalse8274.060
3046961102987NoneItem 2.02Supply of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL ---- etc., complete with all leadSet603.39603.396.0FalseNoneNoneFalseNoneFalse3620.340
3046962102987NoneItem 2.02Erection of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL ---- etc., complete with all leadSet318.42318.426.0FalseNoneNoneFalseNoneFalse1910.520
3046963102987NoneItem 6.06Supply and fixing of 11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP Rod) ---- etc., complete with all leadNos254.0254.018.0FalseNoneNoneFalseNoneFalse4572.00
3046964102987NoneItem 6.10Supply and fixing of 11 kV, 45 KN Polymeric Insulator ---- etc., complete with all leadNos230.45230.4518.0FalseNoneNoneFalseNoneFalse4148.10
3046965102987NoneItem 13.12Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., complete with all leadNos59.4759.4718.0FalseNoneNoneFalseNoneFalse1070.460
3046966102987NoneItem 6.08Supply and fixing of 15 Strain Insulator ---- etc., complete with all leadSet73.173.14.0FalseNoneNoneFalseNoneFalse292.40
3046967102987NoneItem 7.02Supply of Rabbit ACSR Conductor ---- etc., complete with all leadKm57283.9357283.931.0FalseNoneNoneFalseNoneFalse57283.930
3046968102987NoneItem 6.02Erection of Rabbit ACSR Conductor ---- etc., complete with all leadKm5403.285403.281.0FalseNoneNoneFalseNoneFalse5403.280
3046969102987NoneItem 10.01Supply and fixing of PG Clamps for Rabbit Conductor ---- etc., complete with all leadNo173.46173.4615.0FalseNoneNoneFalseNoneFalse2601.90
3046970102987NoneItem 2.16Supply of Spiral Earth Electrode ---- etc., complete with all leadNo296.12296.129.0FalseNoneNoneFalseNoneFalse2665.080
3046971102987NoneItem 2.16Erection of Spiral Earth Electrode ---- etc., complete with all leadNo115.23115.239.0FalseNoneNoneFalseNoneFalse1037.070
3046972102987NoneItem 68.17Supply and fixing of Caution/Danger Board ---- etc., complete with all leadNo185.85185.855.0FalseNoneNoneFalseNoneFalse929.250
3046973102987NoneItem 4.02Supply of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete with all leadEach110.27110.276.0FalseNoneNoneFalseNoneFalse661.620
3046974102987NoneItem 5.09Erection of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete with all leadEach52.0452.046.0FalseNoneNoneFalseNoneFalse312.240
3046975102987NoneItem 41.01Load Break Switch with Panel ---- etc., complete with all leadNo90743.1290743.121.0FalseNoneNoneFalseNoneFalse90743.120
3046976102987NoneItem 58.0111 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT & 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem & 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch (HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated) as per revised Specification (Dwg No. BESCOM/GM/QS&S/-- Dtd 24.11.2018) ---- etc., complete with all leadNo301661.81301661.811.0FalseNoneNoneFalseNoneFalse301661.810
3046977102987NoneItem 53.01CT PT Operated ETV Meter 0.2s Accuracy Class with ABT feature and DLMS protocal with ToD with RS 232 PortUNIDIRACTIONAL (Used for HT Installation, LT Metering Cubicle 50-150 KW ---- etc., complete with all leadNo24302.9924302.991.0FalseNoneNoneFalseNoneFalse24302.990
3046978102987NoneItem Least Quotation RateSupply, installation, testing and commissioning of 500 kVA , 11kV/433V, 3 phase, 50 Hz, Delta star, DYn11 , outdoor, natually cooled, Oil Immersed copper double wound transformer Conforming to IS: 11801180 3 LEVEL Contained in mild steel radiator Cooled tank with first fill of oil as per IS: 335 with On load tap changer from 5 to 15 in steps of 1.25%, remote tap changes panel with AVR, class F insulation, Rating and Diagram Plate, Earthing Terminals - 2 Nos,Liffting Lugs,Air release hole with plug,Dehydrating Silica Gel Breather,Prismatic Oil level Guage,Oil Conservator with drain plug,Thermometer pocket,Jacking Lugs,Bottom drain cum filter valve,Top filter valve,4 Nos. Bi-Directional rollers,Pressure relief device,Marshalling Box [wherever applicable],100 mm OTI/ 150 mm OTI with alarm & trip,WTI with alarm and trip,Buchholz Relay with alarm and trip,Shut off valves for Buchholz Relay,Magnetic Oil Level guage,Radiators - Fixed / Detachable With HT & LT Cable end boxes / Provison for LV Bus Duct type, The transformer shall have suitable enclosure for providing neutral CT on earthed star point with connector for connection to REF relay provided in Main panel. All routing test as per IS shall be conducted on the transformer. The Transformer Enclosure shall have suitably designed Louvers for Air Circulation & efficient Cooling, required Danger boards, signages, lettering etc.. The enclosure shall be Epoxy Powder coated. The transformer shall be subjected to all routine tests as per IS/IEC standards. Type test certificate shall be submitted (As Per EC BC Norms) ---- etc., complete with all leadEach433989.84433989.841.0FalseNoneNoneFalseNoneFalse433989.840
3046979102987NoneItem 12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia ---- etc., complete with all leadNo4348.894348.8910.0FalseNoneNoneFalseNoneFalse43488.90
3046980102987NoneItem 12.58.3Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI strip ---- etc., complete with all leadm158.59158.5980.0FalseNoneNoneFalseNoneFalse12687.20
3046981102987NoneItem 12.58.9Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 40x6mm Copper strip ---- etc., complete with all leadMtr2035.682035.6880.0FalseNoneNoneFalseNoneFalse162854.40
3046982102987NoneItem 12.58.11Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm Copper plate ---- etc., complete with all leadEach9194.629194.6210.0FalseNoneNoneFalseNoneFalse91946.20
3046983102987NoneItem 45.07Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Outdoor ---- etc., complete with all leadSet5039.015039.014.0FalseNoneNoneFalseNoneFalse20156.040
3046984102987NoneItem 45.04Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Indoor ---- etc., complete with all leadSet3887.983887.982.0FalseNoneNoneFalseNoneFalse7775.960
3046985102987NoneItem 36.0111 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. 95 Sqmm, (54 GI Wires - 2.5 mm Dia) ---- etc., complete with all leadKm1102296.171102296.170.1FalseNoneNoneFalseNoneFalse110229.6170
3046986102987NoneItem 38Providing chain link fencing 50 mm size of 8 guage properly stretched between rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be welded to the Pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts, cutting, bending wherever necessary, wastage and lapping etc., complete as per the direction of the engineer incharge for work including two coats of approved quality paint over one coat of primer paint. ---- etc., complete with all leadSqm1222.891222.89150.0FalseNoneNoneFalseNoneFalse183433.50
3046987102987NoneItem 5.42.1Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete with all leadSq CM0.620.62170000.0FalseNoneNoneFalseNoneFalse105400.00
3046988102987NoneItem 5.40.5Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 1000Amps double run of 4x60x10mm Aluminum Strips ---- etc., complete with all leadm13108.6213108.628.0FalseNoneNoneFalseNoneFalse104868.960
3046989102987NoneItem 5.41.3Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75x75x6mm ---- etc., complete with all leadm687.65687.6512.0FalseNoneNoneFalseNoneFalse8251.80
3046990102987NoneItem 5.41.5Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75x150x75x6mm C channel ---- etc., complete with all leadm1147.311147.3112.0FalseNoneNoneFalseNoneFalse13767.720
3046991102987NoneItem 5.15.20Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 800Amps 50kA ---- etc., complete with all leadEach61826.161826.11.0FalseNoneNoneFalseNoneFalse61826.10
3046992102987NoneItem 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete with all leadEach638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3046993102987NoneItem 10.1.13Supplying, installing, testing and commissioning of 250KVA/200kw Diesel Generator set with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specificationsEngine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming toIS/IEC 60034-1. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,- Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode. Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA 1mtrat 75load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at rated load made on special purpose CNC machines for consistency in quality and workmanship, Insulation material meets exacting IS 8183 specifications for better sound attenuation, Flush styling - no projections, Fluid drains for lube oil and fuel, Fuel filling point inside the enclosure. ---- etc., complete with all leadSet2359453.722359453.721.0FalseNoneNoneFalseNoneFalse2359453.720
3046994102987NoneItem 10.2.7Supply, Erection, testing and commissioning of AMF panel suitable for .....KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .....amps 4 pole contactor for alternator with thermal O/L relay,..... Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, ....capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Battery charger unit with inbuilt Auto/Manual and flat/Boost facility. 250 KVA ---- etc., complete with all leadEach348218.47348218.471.0FalseNoneNoneFalseNoneFalse348218.470
3046995102987NoneItem Least Quotation RateSupply & installation of exhaust gas piping of suitable diameter as per manufactures standard welded black MS, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti- vibration mountings, insulation of exhaust system with mineral wool / Rockwool, 50mm thick wire mesh & aluminum cladding etc. ---- etc., complete with all leadm9440.09440.010.0FalseNoneNoneFalseNoneFalse94400.00
3046996102987NoneItem Least Quotation RateSupply and installing of DG set stack using angular structure, channel, necessary nut and bolt and all required accessories for erecting exhaust pipe from 2 nos DG set and space provision for provinding exhaust pipe for 2 more DG set in future. The design of the stack with foundation shall be got approved before fabrication. The foundation for the stack shall be measured separately. ---- etc., complete with all leadKg236.0236.0600.0FalseNoneNoneFalseNoneFalse141600.00
3046997102987NoneItem Least Quotation RateSupply and laying of 2Cx2.5SQ MM and 6CX2.5 SQ MM Sheilded Sensor and control Cables ---- etc., complete with all leadm236.0236.080.0FalseNoneNoneFalseNoneFalse18880.00
17103318720000NoneNoneBuildingsBORE WELL647382.59
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3046998102988NonePWD SR 2023-24 V-5 Page No 140 Item No 12.4Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indic ting the location of the site, recommended depth of casing pipe required seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casin pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging techn al personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of R . 100/- is to be deducted for Dry Borewell towards yield test. tc. complete. ---- etc., complete with all leadEach6551.836551.831.0FalseNoneNoneFalseNoneFalse6551.830
3046999102988NonePWD SR 2023-24 V-6 Page No 140 Item No 12.1.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 0 to 50 Mtrs ---- etc., complete with all leadm458.43458.4350.0FalseNoneNoneFalseNoneFalse22921.50
3047000102988NonePWD SR 2023-24 V-7 Page No 141 Item No 12.1.2Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 50 to 100 Mtrs ---- etc., complete with all leadm574.89574.8950.0FalseNoneNoneFalseNoneFalse28744.50
3047001102988NonePWD SR 2023-24 V-8 Page No 142 Item No 12.1.3Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 100 to 150 Mtrs ---- etc., complete with all leadm610.82610.8250.0FalseNoneNoneFalseNoneFalse30541.00
3047002102988NonePWD SR 2023-24 V-9 Page No 143 Item No 12.1.4Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 150 to 200 Mtrs ---- etc., complete with all leadm708.7708.750.0FalseNoneNoneFalseNoneFalse35435.00
3047003102988NonePWD SR 2023-24 V-10 Page No 144 Item No 12.1.5Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 200 to 250 Mtrs ---- etc., complete with all leadm831.36831.3650.0FalseNoneNoneFalseNoneFalse41568.00
3047004102988NonePWD SR 2023-24 V-11 Page No 145 Item No 12.1.6Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 250 to 300 Mtrs ---- etc., complete with all leadm916.86916.8650.0FalseNoneNoneFalseNoneFalse45843.00
3047005102988NonePWD SR 2023-24 V-12 Page No 146 Item No 12.1.7Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 300 to 350 Mtrs ---- etc., complete with all leadm1075.451075.4550.0FalseNoneNoneFalseNoneFalse53772.50
3047006102988NonePWD SR 2023-24 V-5 Page No 143 Item No 12.32Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 nd latest ammendments, electrical resistance welded steel tubes, terial and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixe with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. ---- etc., complete with all leadm2394.982394.9835.0FalseNoneNoneFalseNoneFalse83824.30
3047007102988NonePWD SR 2023-24 V-5 Page No 155 Item No 13.28Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments. ---- etc., complete with all leadm681.45681.45200.0FalseNoneNoneFalseNoneFalse136290.00
3047008102988NonePWD SR 2023-24 V-5 Page No 143 Item No 12.33Providing and fixing MS casing collars per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thic ness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments. ---- etc., complete with all leadNos185.85185.851.0FalseNoneNoneFalseNoneFalse185.850
3047009102988NonePWD SR 2023-24 V-5 Page No 143 Item No 12.34Providing and laying at site of wor MS asing caps as per IS 1239 (part- II) 1982 with all latest amendm nts if any for any dia. The thickness of plate used for covering one e shall be 3mm (minimum). The dimensions of caps and olars shall be strictly as per IS 1239 (Part-II) 1982 with all mendments including cost of material and labour charges for fixing, if a y etc. complete with all lead and lifts and as directed by the Engineer in charge. ---- etc., complete with all leadNos203.19203.191.0FalseNoneNoneFalseNoneFalse203.190
3047010102988NonePWD SR 2023-24 95 Page No 18-19 SR Item No 13.81.3Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) ---- etc., complete with all leadNos260.19260.191.0FalseNoneNoneFalseNoneFalse260.190
3047011102988NonePWD SR 2023-24 V-5 Page No 152 Item No 13.13.6Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For HP etc Complete.5.00 HP - 90 LPM @ 110 m = 15 STG Outlet Dia - 2.00" ---- etc., complete with all leadEach39817.7439817.741.0FalseNoneNoneFalseNoneFalse39817.740
3047012102988NonePWD SR 2023-24 V-5 Page No 155 Item No 13.23.2Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protectionsuitable for thepumpdescribedabove 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete.3 to 6 HP pumps ---- etc., complete with all leadEach11832.4511832.451.0FalseNoneNoneFalseNoneFalse11832.450
3047013102988NonePWD SR 2023-24 V-5 Page No 155 Item No 13.29Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets ---- etc., complete with all leadSet1920.451920.451.0FalseNoneNoneFalseNoneFalse1920.450
3047014102988NonePWD SR 2023-24 V-5 Page No 155 Item No 13.31Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. ---- etc., complete with all leadJob49.5649.56100.0FalseNoneNoneFalseNoneFalse4956.00
3047015102988NonePWD SR 2023-24 V-5 Page No 156 Item No 13.32Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. ---- etc., complete with all leadJob8053.58053.51.0FalseNoneNoneFalseNoneFalse8053.50
3047016102988NonePWD SR 2023-24 V-5 Page No 156 Item No 13.33Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work. ---- etc., complete with all leadJob1672.651672.651.0FalseNoneNoneFalseNoneFalse1672.650
3047017102988NonePWD SR 2023-24 V-6 Page No 7 Item No 2.6.2Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.3C x 4 mm2 ---- etc., complete with all leadm208.15208.15275.0FalseNoneNoneFalseNoneFalse57241.250
3047018102988NonePWD SR 2023-24 V-6 Page No 20 Item No 5.42.2Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 16SWG ---- etc., complete with all leadSq CM0.530.5330000.0FalseNoneNoneFalseNoneFalse15900.00
3047019102988NonePWD SR 2023-24 V-6 Page No 21 Item No 5.44.4Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 600mmx600mmx170mm. ---- etc., complete with all leadEach17990.2817990.281.0FalseNoneNoneFalseNoneFalse17990.280
3047020102988NonePWD SR 2023-24 V-6 Page No 14 Item No 5.6.6Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws.20" x 20" x 2.5" ---- etc., complete with all leadEach404.07404.071.0FalseNoneNoneFalseNoneFalse404.070
3047021102988NonePWD SR 2023-24 V-6 Page No 17 Item No 5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A SP ---- etc., complete with all leadEach514.18514.181.0FalseNoneNoneFalseNoneFalse514.180
3047022102988NonePWD SR 2023-24 V-6 Page No 57 Item No 13.18.1Fixing of ..... A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling..15A to 63A TPST ---- etc., complete with all leadEach344.44344.441.0FalseNoneNoneFalseNoneFalse344.440
3047023102988NonePWD SR 2023-24 V-6 Page No 19 Item No 5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motor. ---- etc., complete with all leadKvar594.72594.721.0FalseNoneNoneFalseNoneFalse594.720
17103318720000NoneNoneBuildingsSUMP TANK3322374.45
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3047024102989NoneSR 2023-24 V-3 Page No-7 It No-2.5AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer In area of light jungle ---- etc., complete with all leadSqm486.93486.931.789FalseNoneNoneFalseNoneFalse871.117770
3047025102989NoneSR 2023-24 V-1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m. ---- etc., complete with all leadCum126.38126.38536.76FalseNoneNoneFalseNoneFalse67835.72880
3047026102989NoneSR 2023-24 V-1 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete with all leadCum329.57329.57108.024FalseNoneNoneFalseNoneFalse35601.469680
3047027102989NoneSR 2023-24 V-1 Page No-15 It No-2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates. Including FormWork ---- etc., complete with all leadCum7420.377420.3715.812FalseNoneNoneFalseNoneFalse117330.890440
3047028102989NoneSR 2023-24 V-1 Page No-17 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesDomestic & Treated Water Sump & Fire Sump ---- etc., complete with all leadCum8732.838732.8330.624FalseNoneNoneFalseNoneFalse267434.185920
3047029102989NoneSR 2023-24 V-1 Page No-17 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatespump room and sump tank-walls ---- etc., complete with all leadCum14413.4114413.4139.648FalseNoneNoneFalseNoneFalse571462.879680
3047030102989NoneSR 2023-24 V-1 Page No-17 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCover slab ---- etc., complete with all leadCum12717.7212717.7227.84FalseNoneNoneFalseNoneFalse354061.32480
3047031102989NoneSR 2023-24 V-1 Page No-17 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesD. beams- pumproom ---- etc., complete with all leadCum13565.5613565.564.719FalseNoneNoneFalseNoneFalse64015.877640
3047032102989NoneSR 2023-24 V-1 Page No-17 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesE. lintel-beam ---- etc., complete with all leadCum13565.5613565.560.225FalseNoneNoneFalseNoneFalse3052.2510
3047033102989NoneSR 2023-24 V-1 Page No-17 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesStaircase ---- etc., complete with all leadCum12293.7912293.791.84FalseNoneNoneFalseNoneFalse22620.57360
3047034102989NoneSR 2023-24 V-1 Page No-18 It No-2.11 hSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.All other type of structures ---- etc., complete with all leadt97894.6397894.6310.204FalseNoneNoneFalseNoneFalse998916.804520
3047035102989NoneSR 2023-24 V-2 Page No-17 It No-6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all leadSqm1623.091623.0936.12FalseNoneNoneFalseNoneFalse58626.01080
3047036102989NoneSR 2023-24 V-2 Page No-77 It No-11.5.1Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. ---- etc., complete with all leadSqm5548.245548.244.2FalseNoneNoneFalseNoneFalse23302.6080
3047037102989NoneSR 2023-24 V-2 Page No-152 It No-15.14UGT/OHT (inside) waterproofing with Anti-microbial Coating Providing and Applying two component, water-based food grade epoxy resin coating on inside surface of Potable water tank having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 - 300 of US - FDA, having mixing Ratio (Base: Hardener: Water) - 1.1.1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster, and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification. GROUND FLOOR ---- etc., complete with all leadSqm2072.852072.85186.24FalseNoneNoneFalseNoneFalse386047.5840
3047038102989NoneSR 2023-24 V-2 Page No-42 It No-8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm459.67459.67582.24FalseNoneNoneFalseNoneFalse267638.26080
3047039102989NoneSR 2023-24 V-2 Page No-48 It No-8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm142.49142.497.08FalseNoneNoneFalseNoneFalse1008.82920
3047040102989NoneSR 2023-24 V-2 Page No-44 It No-8.21Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm32.2132.21511.12FalseNoneNoneFalseNoneFalse16463.17520
3047041102989NoneSR 2023-24 V-2 Page No-45 It No-8.28Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 Sqm) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm110.27110.27511.12FalseNoneNoneFalseNoneFalse56361.20240
3047042102989NoneSR 2023-24 V-5 Page No-221 It No-18.3Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. ---- etc., complete with all leadKg2430.922430.924.0FalseNoneNoneFalseNoneFalse9723.680
17103318720000NoneNoneBuildingsSEWAGE TREATMENT PLANT 20 KLD MACHINARIES2143470.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3047043102990Nonecode01BAR SCREEN with 20 mm spacingMOC: MSEPMake: Hydrodrops ---- etc., complete with all leadNo11800.011800.01.0FalseNoneNoneFalseNoneFalse11800.00
3047044102990Nonecode02Coarse Bubble DiffusersSize: 80 mm dia x 800 mm longTYPE: Tubular TypeMOC: PVCMake: Energy Equipments/SSI USA ---- etc., complete with all leadNos5605.05605.010.0FalseNoneNoneFalseNoneFalse56050.00
3047045102990Nonecode03Fine Bubble DiffusersSize: 90 mm dia x 800 mm longTYPE: Tubular TypeMOC: EPDMMake: Energy Equipments/SSI USA ---- etc., complete with all leadNos5310.05310.010.0FalseNoneNoneFalseNoneFalse53100.00
3047046102990Nonecode04Raw Effluent PumpsDuty: 12 cum/hr @ 10 m headTYPE: Vertical, Submersible, Non clogMOC: CIMake: CNP/Point/Equiv ---- etc., complete with all leadNos56640.056640.02.0FalseNoneNoneFalseNoneFalse113280.00
3047047102990Nonecode05Filter Feed PumpsDuty: 12 cum/hr @ 35 m headTYPE: Horizontal, Centrifugal, Non clogMOC: CIMake: Kirloskar/Equiv ---- etc., complete with all leadNos47200.047200.02.0FalseNoneNoneFalseNoneFalse94400.00
3047048102990Nonecode06Air Blowers (For SBR Tank)Type: Twin lobe Flow Rate: 160 cum/hrOperating Pressure: 0.5 Kg/cm²Speed: 1440 rpmMOC: CIMake: TMVT/Equiv ---- etc., complete with all leadNos188800.0188800.02.0FalseNoneNoneFalseNoneFalse377600.00
3047049102990Nonecode07Sludge Transfer PumpsDuty: 5 cum/hr @ 10 m headTYPE: Vertical, Submersible, Non clogMOC: CIMake: CNP/Point/Equiv ---- etc., complete with all leadNo29500.029500.01.0FalseNoneNoneFalseNoneFalse29500.00
3047050102990Nonecode08Hypochlorite Dosing PumpCapacity: 0 - 6 lphMOC: PPMake: Positive/Ant/EquivDosing tank capacity: 100 ltsMOC: HDPEMake: Syntex/Infra/Equiv ---- etc., complete with all leadNo53100.053100.01.0FalseNoneNoneFalseNoneFalse53100.00
3047051102990Nonecode09Pressure Sand FilterDuty: 15 cum/hrType: Vertical, CylindricalSize: 800 mm dia x 1200 mm HOSMedia: Graded sand and pebblesMOC:MSEPMake: Hydrodrops ---- etc., complete with all leadNo147500.0147500.01.0FalseNoneNoneFalseNoneFalse147500.00
3047052102990Nonecode10Activated Carbon FilterDuty: 15 cum/hrType: Vertical, CylindricalSize: 800 mm dia x 1200 mm HOSMedia: Activated Carbon, Gravels and pebblesMOC:MSEPMake: Hydrodrops ---- etc., complete with all leadNo147500.0147500.01.0FalseNoneNoneFalseNoneFalse147500.00
3047053102990Nonecode11Filter PressSize: 470 mm x 470 mm with 12 platesMake: Precision/Hydropress/Equiv ---- etc., complete with all leadNo153400.0153400.01.0FalseNoneNoneFalseNoneFalse153400.00
3047054102990Nonecode12Screw PumpDuty: 1 cum/hr @ 60 m headType: Horizontal, screw pump with SS rotor & stator for pressure pumpingMOC: CIMake: Alfa/Equiv ---- etc., complete with all leadNo44840.044840.01.0FalseNoneNoneFalseNoneFalse44840.00
3047055102990Nonecode13Decanter Mechanism ---- etc., complete with all leadNo94400.094400.01.0FalseNoneNoneFalseNoneFalse94400.00
3047056102990Nonecode14Interconnecting piping, fittings & valvesMOC: GI/PVCMake:GI/MS: Tata/Jindal/EquivPVC: Supreme/Equiv ---- etc., complete with all leadLot129800.0129800.01.0FalseNoneNoneFalseNoneFalse129800.00
3047057102990Nonecode15Electrical Control Panel, Type: Powder coated, CRCA, 16 gauge sheet, weather proof, cubicle tyep, floor mounted, Function: Auto manual PLC with HDMI Monitor ---- etc., complete with all leadSet177000.0177000.01.0FalseNoneNoneFalseNoneFalse177000.00
3047058102990Nonecode16UV Disinfection System, Flow: 10 cum/hr, Make: Alfa ---- etc., complete with all leadNo194700.0194700.01.0FalseNoneNoneFalseNoneFalse194700.00
3047059102990Nonecode17Electrical Cabling work ---- etc., complete with all leadLot29500.029500.01.0FalseNoneNoneFalseNoneFalse29500.00
3047060102990Nonecode18Instrumentation: Float switches, pressure guages, flowmeter ---- etc., complete with all leadLot41300.041300.01.0FalseNoneNoneFalseNoneFalse41300.00
3047061102990Nonecode19Erection & Commissioning ---- etc., complete with all leadLS194700.0194700.01.0FalseNoneNoneFalseNoneFalse194700.00
17103318720000NoneNoneBuildingsMODULAR EFFLUENT TREATMENT PLANT 5 KLD1743239.96
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3047062102991Nonecode01Modular - ETP : Consists of MS fabricated ETP plant, effluent transfer pumps, effluent agitator, sludge disposal pump, chemical dosing pumps, MCC panel complete - 10KLD ---- etc., complete with all leadEach1743239.961743239.961.0FalseNoneNoneFalseNoneFalse1743239.960
17103318720000NoneNoneBuildingsNAME PLATES AND SIGNAGES1382901.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3047063102992Nonecode01Pharmacy3D Acrylic Channel letters - 100mm thick - internally lit with LEDs ---- etc., complete with all leadNo65372.065372.01.0FalseNoneNoneFalseNoneFalse65372.00
3047064102992Nonecode02Emergency3D Acrylic Channel letters - 100mm thick - internally lit with LEDs ---- etc., complete with all leadNo147972.0147972.01.0FalseNoneNoneFalseNoneFalse147972.00
3047065102992Nonecode03Department Names - 3D3D 40mm SS Mirror Finish channel letters - Non Lit ---- etc., complete with all leadNo26550.026550.05.0FalseNoneNoneFalseNoneFalse132750.00
3047066102992Nonecode04Floor DirectoryAcid Etching on SS fixed on Acrylic ---- etc., complete with all leadNo15104.015104.05.0FalseNoneNoneFalseNoneFalse75520.00
3047067102992Nonecode05Room Identification SignageSS Acid etching ---- etc., complete with all leadNo1321.61321.620.0FalseNoneNoneFalseNoneFalse26432.00
3047068102992Nonecode06Perpendicular SignageSS Acid etching stuck on Acrylic ---- etc., complete with all leadNo2242.02242.015.0FalseNoneNoneFalseNoneFalse33630.00
3047069102992Nonecode07Nurse Station 3D signage3D Aluminium Channel Letter ---- etc., complete with all leadNo9145.09145.02.0FalseNoneNoneFalseNoneFalse18290.00
3047070102992Nonecode08Ceiling Suspended Direction SignageAluminum Modular Signage using Aluminum alloy 6063 extrusion with Anodizing (thickness typically to be 30 microns. The integrity to meet international specifications ISO 2143-1981) with life time warranty in normal working conditions. Clear Cover : Clear UV protected 1mm thick Poly carbonate sheet with non Glare/glossy finish. Size - 210 X 700 ---- etc., complete with all leadNo4484.04484.08.0FalseNoneNoneFalseNoneFalse35872.00
3047071102992Nonecode09Lift IdenticiationAcrylic Signage ---- etc., complete with all leadNo2950.02950.02.0FalseNoneNoneFalseNoneFalse5900.00
3047072102992Nonecode10Information SignageSS Acid etching ---- etc., complete with all leadNo9145.09145.015.0FalseNoneNoneFalseNoneFalse137175.00
3047073102992Nonecode11Bed NumbersAcrylic Signage ---- etc., complete with all leadNo472.0472.015.0FalseNoneNoneFalseNoneFalse7080.00
3047074102992Nonecode12Mandatory Signage A45MM Sunboard with vinyl ---- etc., complete with all leadNo1770.01770.015.0FalseNoneNoneFalseNoneFalse26550.00
3047075102992Nonecode13Mandatory Signage A05MM Sunboard with vinyl ---- etc., complete with all leadNo2950.02950.05.0FalseNoneNoneFalseNoneFalse14750.00
3047076102992Nonecode14Room Identification SignageSS Acid etching ---- etc., complete with all leadNo1321.61321.610.0FalseNoneNoneFalseNoneFalse13216.00
3047077102992Nonecode15Nurse Station 3D signage3D Aluminium Channel Letter ---- etc., complete with all leadNo9145.09145.02.0FalseNoneNoneFalseNoneFalse18290.00
3047078102992Nonecode16Patient Identification BoardsAcrylic A4 size inserts ---- etc., complete with all leadNo2950.02950.02.0FalseNoneNoneFalseNoneFalse5900.00
3047079102992Nonecode17Floor DirectoryAcid Etching on SS fixed on Acrylic ---- etc., complete with all leadNo10030.010030.02.0FalseNoneNoneFalseNoneFalse20060.00
3047080102992Nonecode18Ceiling Suspended Direction SignageAluminum Modular Signage using Aluminum alloy 6063 extrusion with Anodizing (thickness typically to be 30 microns. The integrity to meet international specifications ISO 2143-1981) with life time warranty in normal working conditions. Clear Cover : Clear UV protected 1mm thick Poly carbonate sheet with non Glare/glossy finish. Size - 210 X 700 ---- etc., complete with all leadNo4484.04484.04.0FalseNoneNoneFalseNoneFalse17936.00
3047081102992Nonecode19Perpendicular SigangeSS Acid etching stuck on Acrylic ---- etc., complete with all leadNo2242.02242.015.0FalseNoneNoneFalseNoneFalse33630.00
3047082102992Nonecode20Department 3D Signage3D 40mm SS Mirror Finish channel letters - Non Lit ---- etc., complete with all leadNo26550.026550.02.0FalseNoneNoneFalseNoneFalse53100.00
3047083102992Nonecode21Lift IdenticiationAcrylic Signage ---- etc., complete with all leadNo2950.02950.04.0FalseNoneNoneFalseNoneFalse11800.00
3047084102992Nonecode22Information SignageSS Acid etching ---- etc., complete with all leadNo8850.08850.03.0FalseNoneNoneFalseNoneFalse26550.00
3047085102992Nonecode23Bed NumbersAcrylic Signage ---- etc., complete with all leadNo472.0472.020.0FalseNoneNoneFalseNoneFalse9440.00
3047086102992Nonecode24Mandatory Signage A45MM Sunboard with vinyl ---- etc., complete with all leadNo1770.01770.08.0FalseNoneNoneFalseNoneFalse14160.00
3047087102992Nonecode25Mandatory Signage A05MM Sunboard with vinyl ---- etc., complete with all leadNo2950.02950.04.0FalseNoneNoneFalseNoneFalse11800.00
3047088102992Nonecode38BUILDING SIGNAGEAluminum Modular Signage using Aluminum alloy 6063 extrusion with Anodizing (thickness typically to be 30 microns. The integrity to meet international specifications ISO 2143-1981) with life time warranty in normal working conditions. Clear Cover : Clear UV protected 1mm thick Poly carbonate sheet with non Glare/glossy finish. Size - 210 X 700. ON THE BUILDING ---- etc., complete with all leadNo419726.0419726.01.0FalseNoneNoneFalseNoneFalse419726.00
17103318720000NoneNoneBuildingsLANDSCAPE WORKS878804.06
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3047089102993Nonecode01SCRAPPING AND REMOVING TOP SOIL:-Scrappingtheareabyremoving0.15msoilandremovingofunwantedplants,grassalongwithroots.25kminitialtransport,including lead, lift loading and unloading charges. (1x1x0.15mt) ---- etc., complete with all leadCum52.9352.93148.5FalseNoneNoneFalseNoneFalse7860.1050
3047090102993Nonecode021st DIGGING: Diggingoftheareafordevelopinglawnincludingremovingweeds,debris if any and breaking of clumps, watering etc. (1x1x0.45mt) ---- etc., complete with all leadCum94.1494.14445.5FalseNoneNoneFalseNoneFalse41939.370
3047091102993Nonecode032nd DIGGING:-Diggingofsoilbyremovinggrassetcifanyandlevellingofthesoiletc .. (1x1x0.45mt) ---- etc., complete with all leadCum47.0747.07445.5FalseNoneNoneFalseNoneFalse20969.6850
3047092102993Nonecode04Procurement of quality red earth/soil and heap around pit (1x1x0.15mt) ---- etc., complete with all leadCum89.6989.69148.5FalseNoneNoneFalseNoneFalse13318.9650
3047093102993Nonecode05Supply of inputs suchassand,FYM,Redearthin1:3:6ratio.mixingandspreadingthe mixture to 7.50cm thickness wherever required.* Red soil-0.0075cum, *Farm Yard manure-0.0225cum, * Sand-0.045cum ---- etc., complete with all leadCum134.93134.9374.25FalseNoneNoneFalseNoneFalse10018.55250
3047094102993Nonecode06Supply of Fertiliser--Super Phosphate -50 gram, Neem oilcake -250gram, Bone meal-250gram, Potash-50gram,Furadan-25gram,Ammonium Sulphate-100gram,Chlorophyriphos-0.05 mili ltr.(Total 750 Gram) per kg 22 rs/- ---- etc., complete with all leadSqm21.0621.06990.0FalseNoneNoneFalseNoneFalse20849.40
3047095102993Nonecode07Procurement of quality lawn grass Bermuda Grass ---- etc., complete with all leadSqm123.9123.9450.0FalseNoneNoneFalseNoneFalse55755.00
3047096102993Nonecode08Procurement of quality lawn grass Mexican Grass ---- etc., complete with all leadSqm247.8247.8450.0FalseNoneNoneFalseNoneFalse111510.00
3047097102993Nonecode09Labour Charges mixing Inputs as perprescribed proportion and quantity and spreading,applyingfertilizers,digging,levelling,anddibblingwithlawngrassataspacingof5cmx5cm& as per the direction of the Officer in charge of the work. - Bermuda Grass turf ---- etc., complete with all leadSqm600.92600.92450.0FalseNoneNoneFalseNoneFalse270414.00
3047098102993Nonecode10Labour Charges mixing Inputs as perprescribed proportion and quantity and spreading,applyingfertilizers,digging,levelling,anddibblingwithlawngrassataspacingof5cmx5cm& as per the direction of the Officer in charge of the work. - Mexican grass turf ---- etc., complete with all leadSqm724.82724.82450.0FalseNoneNoneFalseNoneFalse326169.00
17103318720000NoneNoneBuildingsSEWAGE TREATMENT PLANT 20KLD1657336.55
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3047099102994None2.5AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer In area of light jungle ---- etc., complete with all leadSqm486.93486.930.4FalseNoneNoneFalseNoneFalse194.7720
3047100102994None1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. ---- etc., complete with all leadCum117.71117.7120.09FalseNoneNoneFalseNoneFalse2364.79390
3047101102994None1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m. - 0.00 Mtrs - 3.00 Mtrs do- In all kinds of soils ---- etc., complete with all leadCum126.38126.38120.54FalseNoneNoneFalseNoneFalse15233.84520
3047102102994None1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m. - 3.00 Mtrs - 4.5 Mtrs do- In all kinds of soils ---- etc., complete with all leadCum144.96144.9640.18FalseNoneNoneFalseNoneFalse5824.49280
3047103102994None1.1ALoading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) ---- etc., complete with all leadCum167.27167.27160.72FalseNoneNoneFalseNoneFalse26883.63440
3047104102994None2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates. Including FormWork ---- etc., complete with all leadCum7420.377420.375.27FalseNoneNoneFalseNoneFalse39105.34990
3047105102994None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork - BOTTOM SLAB ---- etc., complete with all leadCum8732.838732.836.54FalseNoneNoneFalseNoneFalse57112.70820
3047106102994None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork - TOP SLAB ---- etc., complete with all leadCum12717.7212717.726.19FalseNoneNoneFalseNoneFalse78722.68680
3047107102994None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork -TOP BEAM ---- etc., complete with all leadCum13565.5613565.561.78FalseNoneNoneFalseNoneFalse24146.69680
3047108102994None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork - RC WALL ---- etc., complete with all leadCum14413.4114413.4127.49FalseNoneNoneFalseNoneFalse396224.64090
3047109102994None2.11HSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.All other type of structures ---- etc., complete with all leadTonne97894.6397894.633.56FalseNoneNoneFalseNoneFalse348504.88280
3047110102994None11.5.1Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all leadSqm1623.091623.0945.6FalseNoneNoneFalseNoneFalse74012.9040
3047111102994None11.5.1Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. ---- etc., complete with all leadSqm5548.245548.243.15FalseNoneNoneFalseNoneFalse17476.9560
3047112102994None15.13STP (inside) waterproofing with Anticorrosive & Protective Coating Providing and Applying two component coal tar epoxy-based coating on inside surface of Sewage & Effluent treatment tank @ 0.30 kg/m2 in 2 coats to achieve a DFT of 200 microns when fully cured. Ensure that this coating is applied over the protective plaster and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Scratch resistance, for 7kg load as per ASTM : D 7027 - 05, Chemical resistance, immersion in dilute acid alkali & salt solutions 7 days confirms to ASTM : C 868, Salt Spray resistance confirms to ASTM : B 117. The finished cost to include surface preparation completely as per specification. ---- etc., complete with all leadSqm2062.942062.94146.27FalseNoneNoneFalseNoneFalse301746.23380
3047113102994None8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm459.67459.67414.4FalseNoneNoneFalseNoneFalse190487.2480
3047114102994None8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm142.49142.495.64FalseNoneNoneFalseNoneFalse803.64360
3047115102994None8.21Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm32.2132.21414.4FalseNoneNoneFalseNoneFalse13347.8240
3047116102994None8.28Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 Sqm) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm110.27110.27414.4FalseNoneNoneFalseNoneFalse45695.8880
3047117102994None18.3Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. ---- etc., complete with all leadNos2430.922430.928.0FalseNoneNoneFalseNoneFalse19447.360
17103318720000NoneNoneBuildingsBITUMINOUS ROAD3999829.87
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3047118102995NoneSR 2023-24 V-3 Page No-7 It No-2.5AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer In area of light jungle ---- etc., complete with all leadSqm486.93486.9326.6FalseNoneNoneFalseNoneFalse12952.3380
3047119102995NoneSR 2023-24 V-1 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. ---- etc., complete with all leadCum117.71117.71798.0FalseNoneNoneFalseNoneFalse93932.580
3047120102995NoneSR 2023-24 V-1 Page No-7 It No-1.4.1Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m ---- etc., complete with all leadCum299.84299.84798.0FalseNoneNoneFalseNoneFalse239272.320
3047121102995NoneSR 2023-24 V-1 Page No-17 It No-3.1Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work ---- etc., complete with all leadCum105.32105.32159.6FalseNoneNoneFalseNoneFalse16809.0720
3047122102995NoneSR 2023-24 V-3 Page No-25 It No-4.11.AMaking 50 mm x 50 mm furrows, 25mm/ 50mm deep, 45 degrees to the center line of the road and at one metre interval in the existing thin bituminous wearing coarse including sweeping and disposal of excavated material.25 mm deep furrow cutting ---- etc., complete with all leadSqm9.919.911596.0FalseNoneNoneFalseNoneFalse15816.360
3047123102995NoneSR 2023-24 V-3 Page No-17 It No-3.7Compacting original ground supporting embankment-Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction. ---- etc., complete with all leadCum130.1130.1239.4FalseNoneNoneFalseNoneFalse31145.940
3047124102995NoneSR 2023-24 V-1Page No-7 It No-1.8Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., complete with all leadCum587.29587.29798.0FalseNoneNoneFalseNoneFalse468657.420
3047125102995NoneSR 2023-24 V-3 Page No-23 It No-4.2VConstruction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 .For Grading -V Material ---- etc., complete with all leadCum3081.393081.39159.6FalseNoneNoneFalseNoneFalse491789.8440
3047126102995NoneSR 2023-24 V-3 Page No-26 It No-4.17Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface andcompactingwithvibratoryrollertoachievethedesireddensity. ---- etc., complete with all leadCum3170.63170.6159.6FalseNoneNoneFalseNoneFalse506027.760
3047127102995NoneSR 2023-24 V-3 Page No-31 It No-5.1Providing and applying primer coat with SS1 grade Bitumen Emulsion on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70 kg/m2 using mechanical means. ---- etc., complete with all leadSqm50.850.81596.0FalseNoneNoneFalseNoneFalse81076.80
3047128102995NoneSR 2023-24 V-3 Page No-31 It No-5.3Providing and applying tack coat with RS1 Bituminous Emulsion using emulsion pressure distributor at the rate of 0.20 kg/m2 on the prepared bituminous surface cleaned with mechanical broom ---- etc., complete with all leadSqm14.8714.871596.0FalseNoneNoneFalseNoneFalse23732.520
3047129102995NoneSR 2023-24 V-3 Page No-29It No-5.6 AProviding and laying Bituminous Macadam with 120 TPH capacity hot mix plant batch type using crushed aggregates of specified grading premixed with bituminous binder VG- 40 @ 3.3% by weight of mix, transported to site, laid over a previously prepared surface with mechanical paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction ---- etc., complete with all leadCum9612.169612.16119.7FalseNoneNoneFalseNoneFalse1150575.5520
3047130102995NoneSR 2023-24 V-3 Page No-43 It No-5.31Providing and laying Semi Dense Bituminous Concrete with 40/60 TPH capacity hot mix plant batch type using crushed aggregates of specified grading premixed with bituminous binder VG-30 @ 5% by weight of mix and filler, transported to site, laid over a previously prepared surface with mechanical paver finisher to the required grade, level and alignment and rolled as per MoRTH V revision. ---- etc., complete with all leadCum12578.3312578.3339.9FalseNoneNoneFalseNoneFalse501875.3670
3047131102995NoneSR 2023-24 V-1 Page No-15 It No-2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates. Including FormWork ---- etc., complete with all leadCum7420.377420.3715.96FalseNoneNoneFalseNoneFalse118429.10520
3047132102995NoneSR 2023-24 V-3 Page No-74 It No-8.42.2Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra)600 x 200 x 100 mm Kerb Stone ---- etc., complete with all leadm309.75309.75532.0FalseNoneNoneFalseNoneFalse164787.00
3047133102995NoneSR 2023-24 V-3 Page No-27 It No-4.19Construction of Median and Island above road level with approved material deposited at site from roadway cutting and excavation for drain and foundation of other structures, spread, graded and compacted as per clause 408 ---- etc., complete with all leadCum454.71454.7171.82FalseNoneNoneFalseNoneFalse32657.27220
3047134102995NoneSR 2023-24 V-3 Page No-66 It No-8.10Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces. ---- etc., complete with all leadSqm135.05135.05372.4FalseNoneNoneFalseNoneFalse50292.620
17103318720000NoneNoneBuildingsDRAIN WORK1549858.89
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3047135102996NoneSR 2023-24 V-3 Page No-7 It No-2.5AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer In area of light jungle ---- etc., complete with all leadSqm486.93486.930.8FalseNoneNoneFalseNoneFalse389.5440
3047136102996NoneSR 2023-24 V-1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m. ---- etc., complete with all leadCum126.38126.38319.2FalseNoneNoneFalseNoneFalse40340.4960
3047137102996NoneSR 2023-24 V-3 Page No-3 It No-1.1ALoading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) ---- etc., complete with all leadCum167.27167.27159.6FalseNoneNoneFalseNoneFalse26696.2920
3047138102996NoneSR 2023-24 V-1 Page No-15 It No-2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates. Including FormWork ---- etc., complete with all leadCum7420.377420.3726.6FalseNoneNoneFalseNoneFalse197381.8420
3047139102996NoneSR 2023-24 V-1 Page No-16 It No-2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWorkBase slab (VENT PORTION) ---- etc., complete with all leadCum8461.018461.0123.94FalseNoneNoneFalseNoneFalse202556.57940
3047140102996NoneSR 2023-24 V-1 Page No-16 It No-2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWorkSide wall ---- etc., complete with all leadCum11089.6711089.6731.92FalseNoneNoneFalseNoneFalse353982.26640
3047141102996NoneSR 2023-24 V-2 Page No-176 It No-17.12Providing and laying 100mm thick pre-cast cover slabs over drains & Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. ---- etc., complete with all leadSqm1149.791149.79239.4FalseNoneNoneFalseNoneFalse275259.7260
3047142102996NoneSR 2023-24 V-1 Page No-18 It No-2.11hSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.All other type of structures ---- etc., complete with all leadt97894.6397894.634.63FalseNoneNoneFalseNoneFalse453252.13690
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17103318730001NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17103318730001NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of KarnatakaNone
17103318730001NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of Karnataka public Procurement on or before the last date and time of bid submission.None
17103319600000NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of Karnataka public Procurement portal due to internet connectivity issues and technical glitches at bidders end.None
17103320910000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17103321030000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidder.None
17103321120000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costs.None
17103321180000NoneNoneELIGIBILITYConditional tenders will not be accepted.None
17103321230000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete mannerNone
17103321280000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt., orders as may be modified from time to timeNone
17103321330000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejectedNone
17103321380000NoneNoneELIGIBILITYEarnest Money Deposit will have to be in any one of the forms as per the instructions in the financial bid document and shall have to be valid for 45 days beyond the validity of the tenderNone
17103321430000NoneNoneELIGIBILITYAll formats prescribed in the bid documents shall be filled in complete manner (section 2 & of the bid document)and shall be uploaded properly, signed by tenderer. Necessary certificates shall be uploaded along with the formats wherever required. General documents section can be used for this purposeNone
17103321510000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bidNone
17103321630000NoneNoneELIGIBILITYIf the tenderer quotes bid price below the estimated contract value (Amount put to tender) then the tenderer has to submit the additional security deposit equal to the difference in cost and the additional security deposit should have a validity for the period of executionNone
17103321680000NoneNoneELIGIBILITYIf the numbers of page to be attached in one particular attachment is more, then all the pages can be put into one folder, zipped and then attached or else all the pages can be pasted in one word file and then this word file could be converted to PDF (portable documents format) format and then attached. (Please contract help desk from 9.00 AM to 9.00 PM ( Monday to Saturday) Ph No: 91-8046010000 and 91-8068948777 or send query through Karnataka public procurement portal through query option on or before specified timeNone
17103321740000NoneNoneELIGIBILITYThe Contractor shall strictly take all reasonable steps to protect the environment on and off the site and to avoid damage or nuisance to persons or to property of the public or others resulting from pollution, noise or other causes arising as a consequence of his methods of operationNone
17103321780000NoneNoneELIGIBILITYMaterials like, steel (primary), cement, bitumen etc., required for the work shall be procured by the tenderer themselves and should be got tested positive by the quality control authority before use on the workNone
17103321830000NoneNoneELIGIBILITYTenderer should have latest GST Registration and latest clearance certificate in their nameNone
17103321880000NoneNoneELIGIBILITYThe Rates quoted by the tenderer shall be inclusive of GSTNone
17103321920000NoneNoneELIGIBILITYSpecial Instructions to tenderers - as per bid documentNone
17103321990000NoneNoneELIGIBILITYThe Defects Liability Period is 1 year from the date of completion of the workNone
17103322060000NoneNoneELIGIBILITYTotal value of Civil Engineering Construction works executed in the and payments received in the last five year i.e., 2018-19, 2019-20, 2020-21 2021-22 & 2022-23None
17103322110000NoneNoneELIGIBILITYThe Tenderers are bound to furnish the original certified documents to the employer within 3 days from the day of opening of technical bid for verification, failing which the bid of tenderer will be considered as technically non responsiveNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneClause ITT 3.2(b)To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2018-19 to 2022-23) The tenderer should have been Satisfactorily completed at least one Satisfactorily completed at least one Similar work of value not less than Rs.1016.50 Lakhs as prime contractor. Note : The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (b).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(c) To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2018-19 to 2022-23).Executed in any one year, the following minimum quantities of work Sl. No Description of key items of works Quantity 1)Earthwork Excavation 3700.00 Cum,2)RCC and PCC 1780.00 Cum,3)Steel Reinforcement for RCC work 205.00 Tonne, 4)Cement Concrete Block Masonry/Solid Block Masonry /Load Bearing Wall/BBM 4710.00 Sqm, 5)Flooring/Dadooing(Vitrified/Granite/Ceramic/Cement concrete/cladding/dadooing) 4500.00 Sqm,6)Plastering 12650.00 Sqm,7)Painting 13100.00 Sqm, 8)M.S grill work 1600.00 kg 9)WPC 1600.00 Sqm 10)Lift 1 No Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2(c)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(d) The tenderer or his identified sub contractor should possess required valid electrical license for executing building electrification works issued by KPWD/ Government electrical Inspectorate and should have executed similar Building electrical works totaling Rs.175.00 Lakhs in any one financial year.Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (d).The letter of willingness of the sub contractor to be engaged for electrical works, should be obtained and uploaded in the KPP-portal.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(e)The Tenderer or his identified sub-contractor should possess valid license for executing water supply/sanitary engineering works issued by BWSSB/ KUWS&DB and should have executed similar building water supply/sanitary engineering works totaling Rs.26.00 Lakhs in any one financial year. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (e).The letter of willingness of the sub contractor to be engaged for water supply & Sanitary works, should be obtained and uploaded in the KPP-portal.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(f) The Tenderer or his identified sub-contractor should have executed similar Fire Fighting works totaling to Rs.51.50 Lakhs in any one year. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (f). 3.2 (f).The letter of willingness of the sub contractor to be engaged for Fire Fighting works, should be obtained and uploaded in the KPP-portalPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(g) The Tenderer or his identified sub-contractor should have executed similar MGPLS works works totaling to Rs.54.00 Lakhs in any one year. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (g). 3.2 (g).The letter of willingness of the sub contractor to be engaged for MGPLS works, should be obtained and uploaded in the KPP-portalPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(h) The Tenderer or his identified sub-contractor should have executed similar MODULAR OT works works totaling to Rs.60.00 Lakhs in any one year. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (h). 3.2 (h).The letter of willingness of the sub contractor to be engaged for MODULAR OT works, should be obtained and uploaded in the KPP-portalPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(i) The Tenderer or his identified sub-contractor should have executed similar HVAC works totaling to Rs.68.00Lakhs in any one year. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (i). 3.2 (i).The letter of willingness of the sub contractor to be engaged for HVAC works, should be obtained and uploaded in the KPP-portalPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneList of Minimum Key Personnel to be deployed by the contractor at site for Contract work Sl No Position Qualification and Requirement No of Persons. 1)Project Manager B.E. Civil with minimum experience of 15 years in the Construction of buildings 1 (One), 2)Site Engineer BE Civil with minimum experience of 7 years in the Construction of buildings or Diploma in Civil Engineering with minimum experience of 10 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years 2 (Two), 3)Electrical Engineer BE Electrical with minimum experience of 5 years in the Construction of buildings Or Diploma in Electrical Engineering with minimum experience of 10 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years 1 (One).Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Educational and Experience certificates should be uploaded
NoneNoneNoneNoneKPWD Class-I Registration CertificateCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Registration certificate issued by competent authority
NoneNoneNoneNoneClause ITT 3.3 (a)Equipment capacity Each tenderer should further demonstrate(a) available by owning at least 50% of the required/specified key and critical equipment for this work and (b) the remaining 50% can be deployed on ease/hire basis for all works provided, the relevant documents (commitment agreements etc.,) for availability for this work are furnished. Sl.No. Description of Equipment Quantity 1) Min 10 cft capacity Concrete Mixer-2 Nos. 2)Steel Centering sheets 1000 sqmtr 3).Tipper-02No 4).Excavator-2 No.5). Water tanker -2No 6). Bar Bending and cutting machine -1 No 7).Generator 500 KVA-1NoCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Invoices and receipt to be uploaded
NoneNoneNoneNoneClause 3.6 Tenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated for prime contractor are as under Assessed available tender capacity AxNx1.5- B Where A maximum value of civil engineering works executed in any one year during the last five years 2018-19 to 2022-23 updated to 2023-24 price level taking into account the completed as well as works in progress. N Number of years prescribed for completion of the works for which tenders are invited. B Value, at 2023 24 price level of existing commitments and ongoing works to be completed during the next 15 months. Note The statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Ongoing & Commitment work
NoneNoneNoneNoneClause 3.3(b)Liquid assets and /or availability of credit facilities of not less than Rs.610.00 Lakhs (Credit lines / letter of credit/ certificates from banks for meeting the fund requirement etc.(As per the prescribed format in clause 1.10 of SECTION 3, QUALIFICATION INFORMATION of this document.) as prime Contractor.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneClause ITT 3.2(a):To qualify for award of this contract, each Tenderer in his / its name should have in the last five years i.e.(2018-19 to 2022-23).The tenderer should have been achieved in at least two financial years a minimum annual financial turnover (in all classes of civil Engineering construction works only) of Rs.3253.00 Lakhs. Note: For Clause 3.2 (a) the Turn over certificate and balance sheet duly certified by the charted accountant is to be submitted.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Work done certificateTrueTechnical Bid
GST certificate & latest paid receiptTrueTechnical Bid
PWD Class-I registration certificateTrueTechnical Bid
ESI and EPF Certificate and paid receiptTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1710334358000
version0
createdDateNone
modifiedDateNone
blockNumberOffice of the Chief Engineer, Engineering Wing, H and FWD, Arogya Soudha, 3rd Floor, 1st Cross, Magadi Road
streetNone
cityBengalruu
stateKarnataka
pin560023
tenderRecallDTONone