tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1710222698000 | 1 | None | None | Buildings | Construction of Watchmans Quarter CIVIL | 887076.79 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2994606 | 99569 | None | V-1 1.14.1 Pg. 8 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth | Cum | 107.1 | 107.1 | 5.0 | False | None | None | False | None | False | 535.5 | 0 | 2994607 | 99569 | None | V-1 1.14.1 Pg. 37 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usageof machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 107.1 | 107.1 | 35.98 | False | None | None | False | None | False | 3853.458 | 0 | 2994608 | 99569 | None | V-1 2.1.2 Pg. 15 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) | Cum | 5947.2 | 5947.2 | 4.97 | False | None | None | False | None | False | 29557.584 | 0 | 2994609 | 99569 | None | V-2 5.2 Pg. 9 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6948.9 | 6948.9 | 16.6 | False | None | None | False | None | False | 115351.74 | 0 | 2994610 | 99569 | None | V-1 1.9 Pg. 34 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 279.3 | 279.3 | 39.91 | False | None | None | False | None | False | 11146.863 | 0 | 2994611 | 99569 | None | V-1 I no 2.2.3 P no 15 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregatesas per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6652.8 | 6652.8 | 3.89 | False | None | None | False | None | False | 25879.392 | 0 | 2994612 | 99569 | None | V-1 Addendum I Sl.no 1.b P.no 111 | Additional Form work for Shuttering, Centering work for Footing work 3% | Cum | 199.58 | 199.58 | 3.89 | False | None | None | False | None | False | 776.3662 | 0 | 2994613 | 99569 | None | V-1 I no 2.5.2 P no 16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 7185.15 | 7185.15 | 1.06 | False | None | None | False | None | False | 7616.259 | 0 | 2994614 | 99569 | None | V-1 Addendum I Sl.no 9 P.no 111 | Additional Form work for Shuttering, Centering work for Column work 70% | Cum | 5029.61 | 5029.61 | 1.06 | False | None | None | False | None | False | 5331.3866 | 0 | 2994615 | 99569 | None | V-1 I no 2.5.2 P no 16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 7185.15 | 7185.15 | 1.92 | False | None | None | False | None | False | 13795.488 | 0 | 2994616 | 99569 | None | V-1 Addendum I Sl.no 2 P.no 111 | Additional Form work for Shuttering, Centering work for Plinth beam work 50% | Cum | 3592.58 | 3592.58 | 1.92 | False | None | None | False | None | False | 6897.7536 | 0 | 2994617 | 99569 | None | V-1 I no 2.5.2 P no 16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 7185.15 | 7185.15 | 2.24 | False | None | None | False | None | False | 16094.736 | 0 | 2994618 | 99569 | None | V-1 Addendum I Sl.no 9 P.no 111 | Additional Form work for Shuttering, Centering work for Column work 70% | Cum | 5029.61 | 5029.61 | 2.24 | False | None | None | False | None | False | 11266.3264 | 0 | 2994619 | 99569 | None | V-1 I no 2.5.2 P no 16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 7185.15 | 7185.15 | 3.04 | False | None | None | False | None | False | 21842.856 | 0 | 2994620 | 99569 | None | V-1 Addendum I Sl.no 14 P.no 111 | Additional Form work for Shuttering, Centering work for Lintel & Roof beam work 60% | Cum | 4311.09 | 4311.09 | 3.04 | False | None | None | False | None | False | 13105.7136 | 0 | 2994621 | 99569 | None | V-1 I no 2.5.2 P no 16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 7185.15 | 7185.15 | 4.79 | False | None | None | False | None | False | 34416.8685 | 0 | 2994622 | 99569 | None | V-1 Addendum I Sl.no 15 P.no 111 | Additional Form work for Shuttering, Centering work for Roof Slab work 50% | Cum | 3592.58 | 3592.58 | 4.79 | False | None | None | False | None | False | 17208.4582 | 0 | 2994623 | 99569 | None | V-1 I no 2.5.2 P no 16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 7185.15 | 7185.15 | 0.34 | False | None | None | False | None | False | 2442.951 | 0 | 2994624 | 99569 | None | V-1 Addendum I Sl.no 19 P.no 111 | Additional Form work for Shuttering, Centering work for Chejja 45% | Cum | 3233.32 | 3233.32 | 0.34 | False | None | None | False | None | False | 1099.3288 | 0 | 2994625 | 99569 | None | V-1 I no 2.11a P no 18 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Buildings | t | 93929.85 | 93929.85 | 1.46 | False | None | None | False | None | False | 137137.581 | 0 | 2994626 | 99569 | None | V-2 I no 6.8 P no 14 | Providing Brick work with common burnt clay Non Modular bricks ofclass designation 3.5 in superstructure above plinth level in all shapes andsizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost ofall materials, labour, scaffolding and usage charges of machinery & otherincidental charges complete as per the direction of engineer incharge ofwork. | Cum | 8367.45 | 8367.45 | 16.22 | False | None | None | False | None | False | 135720.039 | 0 | 2994627 | 99569 | None | V-2 I no 8.1.2 P no 41 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement:6 fine sand) including rounding off corners wherever required smoothrendering, providing and removing scaffolding, including cost of materials,labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 253.05 | 253.05 | 126.39 | False | None | None | False | None | False | 31982.9895 | 0 | 2994628 | 99569 | None | V-2 I no 8.8 P no 42 | Providing 18 mm cement plaster in two coats under layer 12 mm thickcement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finishedwith a top layer 6 mm thick cement plaster with cement mortar 1:6 (1cement : 6 fine sand) to brick masonry including rounding off cornerswherever required smooth rendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specificationsand as per directions of Engineer-in-charge. | Sqm | 389.55 | 389.55 | 85.32 | False | None | None | False | None | False | 33236.406 | 0 | 2994629 | 99569 | None | V-2 I no 8.19.1 P no 44 | Providing Flush/ Ruled pointing: Pointing on stone work with cementmortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining,including cost of materials, labour, curing as per specifications and asper directions of Engineer-in-charge | Sqm | 267.75 | 267.75 | 15.65 | False | None | None | False | None | False | 4190.2875 | 0 | 2994630 | 99569 | None | V-2 I no 8.51 P no 50 | Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plasteredwall surface to prepare the surface even and smooth complete as perspecifications and as per directions of Engineer in charge. | Sqm | 105.0 | 105.0 | 126.39 | False | None | None | False | None | False | 13270.95 | 0 | 2994631 | 99569 | None | V-2 8.27 Pg. 45 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 55.65 | 55.65 | 154.39 | False | None | None | False | None | False | 8591.8035 | 0 | 2994632 | 99569 | None | V-2 8.39 Pg. 48 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 133.35 | 133.35 | 154.39 | False | None | None | False | None | False | 20587.9065 | 0 | 2994633 | 99569 | None | V-2 8.30 Pg. 46 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 182.7 | 182.7 | 100.97 | False | None | None | False | None | False | 18447.219 | 0 | 2994634 | 99569 | None | V-2 8.33.2 Pg. 46 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 144.9 | 144.9 | 10.39 | False | None | None | False | None | False | 1505.511 | 0 | 2994635 | 99569 | None | V-2 8.33.3 Pg. 47 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 145.95 | 145.95 | 25.31 | False | None | None | False | None | False | 3693.9945 | 0 | 2994636 | 99569 | None | V-2 9.17.2 Pg. 61 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. | Sqm | 1233.75 | 1233.75 | 28.0 | False | None | None | False | None | False | 34545.0 | 0 | 2994637 | 99569 | None | V-2 12.12 Pg. 99 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 130412.1 | 130412.1 | 0.14 | False | None | None | False | None | False | 18257.694 | 0 | 2994638 | 99569 | None | V-2 12.51 Pg. 104 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | Sqm | 1066.8 | 1066.8 | 2.0 | False | None | None | False | None | False | 2133.6 | 0 | 2994639 | 99569 | None | V-2 12.57.6 Pg. 105 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification. 35 mm thick both side commercial ( SR for Buildings VOL II for the year 2021-22. I. No. 12.57.6 P.No. 106) | Sqm | 3488.1 | 3488.1 | 4.62 | False | None | None | False | None | False | 16115.022 | 0 | 2994640 | 99569 | None | V-2 11.11.1 Pg. 79 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and 12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). | Kg | 155.4 | 155.4 | 189.0 | False | None | None | False | None | False | 29370.6 | 0 | 2994641 | 99569 | None | V-2 11.34B Pg. 86 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. | Kg | 192.15 | 192.15 | 189.0 | False | None | None | False | None | False | 36316.35 | 0 | 2994642 | 99569 | None | V-2 12.61 Pg. 105 | Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete. | Nos | 1039.5 | 1039.5 | 2.0 | False | None | None | False | None | False | 2079.0 | 0 | 2994643 | 99569 | None | V-2 12.74.1 Pg. 107 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm | Nos | 107.1 | 107.1 | 6.0 | False | None | None | False | None | False | 642.6 | 0 | 2994644 | 99569 | None | V-2 12.58 Pg. 105 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. | Each | 126.0 | 126.0 | 4.0 | False | None | None | False | None | False | 504.0 | 0 | 2994645 | 99569 | None | V-2 12.73.1 Pg. 106 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : | Each | 46.2 | 46.2 | 4.0 | False | None | None | False | None | False | 184.8 | 0 | 2994646 | 99569 | None | V-2 12.72 Pg. 106 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : | Each | 86.1 | 86.1 | 4.0 | False | None | None | False | None | False | 344.4 | 0 |
| 1710222698000 | 1 | None | None | Buildings | Construction of Watchmans Quarter water supply | 43774.5 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2994647 | 99570 | None | V-2 13.34 Pg. 12 | Providing and placing on Terrace ( at all floor levels) polyethylene water storage tanks IS:12701 marked with cover and suitable locking arrangement and making holes for inlet, outlet and overflow pipes but without fittings and base support of tanks. | l | 9.45 | 9.45 | 1000.0 | False | None | None | False | None | False | 9450.0 | 0 | 2994648 | 99570 | None | V-2 13.32.2 Pg.122 | 13.86 Providing and fixing Chlorinated Poli Vinyl Chloride (CPVC) pipes conforming to IS 15778 having terminal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this including fixing the pipe with clamp at 1.00mtrs spacing . This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications. (Internal)(Concealed work including cutting chasses & good the wall Etc) DSR 2021-22 V-2 13.32.2 | m | 397.95 | 397.95 | 20.0 | False | None | None | False | None | False | 7959.0 | 0 | 2994649 | 99570 | None | V-5 10.1.1 Pg. 113 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and cmmissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 25mm dia, 10 kg/sqcm & class 5 | m | 50.4 | 50.4 | 20.0 | False | None | None | False | None | False | 1008.0 | 0 | 2994650 | 99570 | None | V-5 10.1.2 Pg. 113 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and cmmissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 32mm dia., 10 kg/sqcm & class 5 | m | 70.35 | 70.35 | 20.0 | False | None | None | False | None | False | 1407.0 | 0 | 2994651 | 99570 | None | V-5 10.1.7 Pg. 113 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and cmmissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 110mm dia., 6 kg/sqcm & class 3 | m | 431.55 | 431.55 | 20.0 | False | None | None | False | None | False | 8631.0 | 0 | 2994652 | 99570 | None | V-2 14.10.2.2 Pg. 134 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board 610x460 mm bowl depth 200 mm DSR 2021-22 V-2 I.No 14.10.2.2 Pg.No 126 | m | 2982.0 | 2982.0 | 1.0 | False | None | None | False | None | False | 2982.0 | 0 | 2994653 | 99570 | None | V-2 13.14 Pg. 119 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 g. | Nos | 888.3 | 888.3 | 2.0 | False | None | None | False | None | False | 1776.6 | 0 | 2994654 | 99570 | None | V-2 14.7.1 Pg. 132 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps | Each | 3236.1 | 3236.1 | 1.0 | False | None | None | False | None | False | 3236.1 | 0 | 2994655 | 99570 | None | V-2 14.32.4 Pg. 136 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 1500x450 mm DSR 2021- 22 V-2 I.No 14.32.4 Pg 129 | Nos | 1812.3 | 1812.3 | 1.0 | False | None | None | False | None | False | 1812.3 | 0 | 2994656 | 99570 | None | V-2 13.39 Pg. 123 | Providing stoneware gully trap SP-1 Complete with CI grating brick masonry chamber 150 x 100 mm size P type with non modular common burnt clay bricks of designation 3.5 & with water tight C.I Cover with frame of 300 x 300mm size Inside the weight of cover to be not less than 4.50 kg and frame to be not less than 2.7 kg per standard design. DSR V-2 I.No 13.39 | Nos | 2710.05 | 2710.05 | 2.0 | False | None | None | False | None | False | 5420.1 | 0 | 2994657 | 99570 | None | V-2 13.22.1.2 Pg. 120 | Providing and fixing PTMT grating of approved quality and colour. 125 mm nominal dia DSR 2021-22 I.No 13.22.1.2 Pg. 118 | Nos | 46.2 | 46.2 | 2.0 | False | None | None | False | None | False | 92.4 | 0 |
| 1710222698000 | 1 | None | None | Buildings | Construction of Watchmans Quarter Electrificstion work | 59260.5 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2994658 | 99571 | None | ELE P-1 2.2.1, Pg.05 | Supplying and wiring adopting loop system in the existing PVC conduit/ pipe using copper PVC insulated multistrand 2 x 1.5 sq.mm wire without switch on the existing the matel box the other end of the wires shall be terminated with sufficient loose length in a PVC round block , complete for each outlet Point wiring using class A Materials Short point upto 3 mts from tapping point to out let via switch | Point | 269.0 | 269.0 | 15.0 | False | None | None | False | None | False | 4035.0 | 0 | 2994659 | 99571 | None | ELE P-1 2.2.2 Pg.05 | Supplying and wiring adopting loop system in the existing PVC conduit/ pipe using copper PVC insulated multistrand 2 x 1.5 sq.mm wire without switch on the existing the matel box the other end of the wires shall be terminated with sufficient loose length in a PVC round block , complete for each outlet Point wiring using class A Materials Medium point above 3 mts upto 6mts from tapping point to outlet via switch | Point | 379.0 | 379.0 | 20.0 | False | None | None | False | None | False | 7580.0 | 0 | 2994660 | 99571 | None | ELE P-1 2.2.3 Pg.05 | Supplying and wiring adopting loop system in the existing PVC conduit/ pipe using copper PVC insulated multistrand 2 x 1.5 sq.mm wire without switch on the existing the matel box the other end of the wires shall be terminated with sufficient loose length in a PVC round block , complete for each outlet Point wiring using class A MaterialsLong point above 6 mts upto 10 mts from tapping point to outlet via switch | Point | 555.0 | 555.0 | 10.0 | False | None | None | False | None | False | 5550.0 | 0 | 2994661 | 99571 | None | ELE P-1 It.No.3.4.1 Pg.08 | Supplying and flush mounting powder coated/Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 1-2 Way | Each | 138.0 | 138.0 | 10.0 | False | None | None | False | None | False | 1380.0 | 0 | 2994662 | 99571 | None | ELE P-1 It.No.3.4.3 Pg.08 | Supplying and flush mounting powder coated/Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 4-5 Way | Each | 177.0 | 177.0 | 8.0 | False | None | None | False | None | False | 1416.0 | 0 | 2994663 | 99571 | None | ELE P-1 It.No.3.4.4 Pg.08 | Supplying and flush mounting powder coated/Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 6 Way | Each | 220.0 | 220.0 | 4.0 | False | None | None | False | None | False | 880.0 | 0 | 2994664 | 99571 | None | ELE P-1 It.No.3.4.5 Pg.08 | Supplying and flush mounting powder coated/Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 8 Way | Each | 261.0 | 261.0 | 2.0 | False | None | None | False | None | False | 522.0 | 0 | 2994665 | 99571 | None | ELE P-1 It.No.3.5.1 Pg.08 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 1 to 2 module | Each | 137.0 | 137.0 | 1.0 | False | None | None | False | None | False | 137.0 | 0 | 2994666 | 99571 | None | ELE P-1 It.No.3.5.3 Pg.08 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 4 module | Each | 175.0 | 175.0 | 4.0 | False | None | None | False | None | False | 700.0 | 0 | 2994667 | 99571 | None | ELE P-1 It.No.3.5.4 Pg.08 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 6 module | Each | 234.0 | 234.0 | 2.0 | False | None | None | False | None | False | 468.0 | 0 | 2994668 | 99571 | None | ELE P-1 It.No.3.5.5 Pg.08 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 8 module | Each | 284.0 | 284.0 | 2.0 | False | None | None | False | None | False | 568.0 | 0 | 2994669 | 99571 | None | ELE P-1 It.No.3.6.1 Pg.09 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate 6 amps one way switch | Each | 102.0 | 102.0 | 2.0 | False | None | None | False | None | False | 204.0 | 0 | 2994670 | 99571 | None | ELE P-1 It.No.3.6.2 Pg.09 | 6 amps Two way switch | Each | 166.0 | 166.0 | 2.0 | False | None | None | False | None | False | 332.0 | 0 | 2994671 | 99571 | None | ELE P-1 It.No.3.6.3Pg.09 | 6 Amps 3 way sockets | Each | 171.0 | 171.0 | 2.0 | False | None | None | False | None | False | 342.0 | 0 | 2994672 | 99571 | None | ELE P-1 It.No.3.6.4 Pg.09 | stepped fan Regulator's | Each | 357.0 | 357.0 | 2.0 | False | None | None | False | None | False | 714.0 | 0 | 2994673 | 99571 | None | ELE P-1 It.No.3.6.7 Pg.09 | 16A one way switch | Each | 180.0 | 180.0 | 1.0 | False | None | None | False | None | False | 180.0 | 0 | 2994674 | 99571 | None | ELE P-1 It.No.3.6.10 Pg.09 | 6/16 Amps universal sockets | Each | 236.0 | 236.0 | 1.0 | False | None | None | False | None | False | 236.0 | 0 | 2994675 | 99571 | None | ELE P-1 It.No.3.6.9 Pg.09 | 32 A DP switch | Each | 326.0 | 326.0 | 1.0 | False | None | None | False | None | False | 326.0 | 0 | 2994676 | 99571 | None | ELE P-1 It.No.1.13 Pg.03 | Supply and fixing one metal Fan box with round hook | Each | 117.0 | 117.0 | 1.0 | False | None | None | False | None | False | 117.0 | 0 | 2994677 | 99571 | None | ELE P-1 It.No 1.2.1 Pg.02 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures seen with fish wires where ever necessary 20mm dia | m | 66.0 | 66.0 | 15.0 | False | None | None | False | None | False | 990.0 | 0 | 2994678 | 99571 | None | ELE P-1 It.No 1.2.2 Pg.02 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures seen with fish wires where ever necessary 25mm dia | m | 78.0 | 78.0 | 15.0 | False | None | None | False | None | False | 1170.0 | 0 | 2994679 | 99571 | None | ELE P-1 It.No 1.3.1 Pg.02 | Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20mm dia | m | 68.0 | 68.0 | 20.0 | False | None | None | False | None | False | 1360.0 | 0 | 2994680 | 99571 | None | ELE P-1 It.No 1.3.2 Pg.02 | Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25mm dia | m | 79.0 | 79.0 | 20.0 | False | None | None | False | None | False | 1580.0 | 0 | 2994681 | 99571 | None | ELE P-1 It.No 2.3.2 Pg.05 | WIRING FOR Lighting/Power Circuits using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A. 1.5 sqmm | m | 26.0 | 26.0 | 30.0 | False | None | None | False | None | False | 780.0 | 0 | 2994682 | 99571 | None | ELE P-1 It.No 2.3.3 Pg.05 | WIRING FOR Lighting/Power Circuits using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A. 2.5 sqmm | m | 42.0 | 42.0 | 30.0 | False | None | None | False | None | False | 1260.0 | 0 | 2994683 | 99571 | None | ELE P-1 It.No 2.3.4 Pg.05 | WIRING FOR Lighting/Power Circuits using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A. 4.0 sqmm | m | 63.0 | 63.0 | 30.0 | False | None | None | False | None | False | 1890.0 | 0 | 2994684 | 99571 | None | ELE P-1 It.No 5.19.8 Pg.18 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting. Made out of 14SWG MS enclouser. 8way SP & N | Each | 1854.0 | 1854.0 | 1.0 | False | None | None | False | None | False | 1854.0 | 0 | 2994685 | 99571 | None | ELE P-1 It.No 5.18.1 Pg.17 | Supplying and fixing miniature circuit breaker, on the existing MCB distribution board using necessary fixing materials and C type curve,indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K & complete wiring as required conforming to IEC 60898. 6-32 Amps Sp | Each | 415.0 | 415.0 | 2.0 | False | None | None | False | None | False | 830.0 | 0 | 2994686 | 99571 | None | ELE P-1 It.No 5.18.4 Pg.17 | Supplying and fixing miniature circuit breaker, on the existing MCB distribution board using necessary fixing materials and C type curve,indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K & complete wiring as required conforming to IEC 60898. 6-32 Amps DP | Each | 739.0 | 739.0 | 1.0 | False | None | None | False | None | False | 739.0 | 0 | 2994687 | 99571 | None | ELE P-1 It.No 5.18.5 Pg.13 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP | Each | 1060.0 | 1060.0 | 1.0 | False | None | None | False | None | False | 1060.0 | 0 | 2994688 | 99571 | None | ELE P-1 It.No 12.19.3 Pg.40 | Supplying and fixing of Electronic Ballast suitable for T5 Lamp with housing made of Pre-coated steel/PC, Operating voltage range from 180V to 265V, 50Hz AC power Supply flicker free warm start with over voltage protection, Inrush current protection, De-activated lamp protection& End of Lamp life protection with PF 0.95 & TC(degC) 65 deg C compliance to EN 61347-2-3 (Safety), EN60929(Performance), EN55015(EMI/RFI), EN61000-3-2 (Harmonics), EN 61547 (Surge). Operating voltage range from 180V to 265V, 50Hz AC power Supply (Part-I ELE I.No 12.9.3 Pg.No 40) 1 X 24W | Each | 925.0 | 925.0 | 3.0 | False | None | None | False | None | False | 2775.0 | 0 | 2994689 | 99571 | None | ELE P-1 It.No 6.3.1 Pg.30 | Supplying capacitor type 48" sweep ceiling fan complete with down rod blades , shackle canopies etc suitable for operation on 230V 50 cycles single phase AC supply conforming to ISS - 374 - 1979 and with double ball bearing system 48" Sweep (1200 mm) Regular model | Each | 2984.0 | 2984.0 | 2.0 | False | None | None | False | None | False | 5968.0 | 0 | 2994690 | 99571 | None | ELE P-1 It.No 6.1 Pg.30 | Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply | Each | 1492.0 | 1492.0 | 1.0 | False | None | None | False | None | False | 1492.0 | 0 | 2994691 | 99571 | None | ELE P-1 It.No 12.2.1 Pg.48 | Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws | Each | 246.0 | 246.0 | 1.0 | False | None | None | False | None | False | 246.0 | 0 | 2994692 | 99571 | None | ELE P-1 It.No 13.7.1 Pg.56 | Fixing all types and all capacities fluorescent / false ceiling /spot light / CFL fitting indoors on the wall / ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires . Required nos of round blocks and clamps | Each | 122.0 | 122.0 | 3.0 | False | None | None | False | None | False | 366.0 | 0 | 2994693 | 99571 | None | ELE P-1 It.No 13.10 Pg.57 | Fixing of Wall/ ceiling fan of all capacities and all types to the existing hook together with supplying and fixing a 5 A ceiling rose , necessary length of 23/0.0076 inch PVC insulated twin twisted copper wire and wiring complete | Each | 171.0 | 171.0 | 2.0 | False | None | None | False | None | False | 342.0 | 0 | 2994694 | 99571 | None | ELE P-1 It.No 13.14 Pg.45 | Fixing one exhaust fan in the nitch already left in the wall with bolts & nuts and a 5 Amps, ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire of approved make with wire mesh and any frame if required | Each | 492.0 | 492.0 | 1.0 | False | None | None | False | None | False | 492.0 | 0 | 2994695 | 99571 | None | ELE P-1 ,It No.13.1.2,Pg.56 | Supplying and fixing 32 mm dia class A GI pipe bracket up to 2 mts long bent at suitable angle and fixing to this bracket 70 W MH street light fitting on wall using suitable clamps, bolts and nuts and wiring using suitable capacities of wires complete | m | 1045.0 | 1045.0 | 3.5 | False | None | None | False | None | False | 3657.5 | 0 | 2994696 | 99571 | None | ELEBESCOM P-3 51.04 23 | Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified | Nos | 2172.0 | 2172.0 | 1.0 | False | None | None | False | None | False | 2172.0 | 0 | 2994697 | 99571 | None | ELEBESCOM P-3 51.05 23 | Bentonite clay slurry for earthing in 50 Kg Bag | Nos | 368.0 | 368.0 | 1.0 | False | None | None | False | None | False | 368.0 | 0 | 2994698 | 99571 | None | ELE P-1 , It.No..5.30 Pg.19 | Supplying, fixing and wiring Electronic Trivector Meter (ETV)5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter. | Each | 1380.0 | 1380.0 | 1.0 | False | None | None | False | None | False | 1380.0 | 0 | 2994699 | 99571 | None | ELE P-1 , It.No.5.7.3,Pg. 14 | Supply & Fixing Porcelaine fuse Channel with cut out on existing box using necessary nuts, bolts etc complete .a) 63 Amps | Each | 401.0 | 401.0 | 2.0 | False | None | None | False | None | False | 802.0 | 0 |
| 1710222698000 | 1 | None | None | Buildings | Construction of Toilet Block Civil work | 274372.36 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2994700 | 99572 | None | V-1 1.14.1 8 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 107.1 | 107.1 | 6.98 | False | None | None | False | None | False | 747.558 | 0 | 2994701 | 99572 | None | V-1 1.23 151 | Providing and filling foundation with granite / trap broken metal 100mm and down size with approved sand including hand packing, ramming watering including cost of all material and labourwith all lead and lift complete as per specification. | Cum | 2816.1 | 2816.1 | 3.49 | False | None | None | False | None | False | 9828.189 | 0 | 2994702 | 99572 | None | V-1 2.1.2 15 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 1.96 | False | None | None | False | None | False | 11656.512 | 0 | 2994703 | 99572 | None | V-2 5.2 9 | Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6948.9 | 6948.9 | 3.49 | False | None | None | False | None | False | 24251.661 | 0 | 2994704 | 99572 | None | V-2 5.4 9 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 2.62 | False | None | None | False | None | False | 17576.139 | 0 | 2994705 | 99572 | None | V-1 1.11 7 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 454.65 | 454.65 | 6.0 | False | None | None | False | None | False | 2727.9 | 0 | 2994706 | 99572 | None | V-1 I no 2.5.2 P no 16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 7185.15 | 7185.15 | 0.9 | False | None | None | False | None | False | 6466.635 | 0 | 2994707 | 99572 | None | V-1 Addendum I Sl.no 2 P.no 111 | Additional Form work for Shuttering, Centering work for Plinth beam work 50% | Cum | 3592.58 | 3592.58 | 0.9 | False | None | None | False | None | False | 3233.322 | 0 | 2994708 | 99572 | None | V-1 I no 2.5.2 P no 16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 7185.15 | 7185.15 | 0.45 | False | None | None | False | None | False | 3233.3175 | 0 | 2994709 | 99572 | None | V-1 Addendum I Sl.no 14 P.no 111 | Additional Form work for Shuttering, Centering work for Lintel & Roof beam work 60% | Cum | 4311.09 | 4311.09 | 0.45 | False | None | None | False | None | False | 1939.9905 | 0 | 2994710 | 99572 | None | V-1 I no 2.11a P no 18 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Buildings | t | 93929.85 | 93929.85 | 0.11 | False | None | None | False | None | False | 10332.2835 | 0 | 2994711 | 99572 | None | V-2 I no 6.8 P no 14 | Providing Brick work with common burnt clay Non Modular bricks ofclass designation 3.5 in superstructure above plinth level in all shapes andsizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost ofall materials, labour, scaffolding and usage charges of machinery & otherincidental charges complete as per the direction of engineer incharge ofwork. | Cum | 8367.45 | 8367.45 | 8.23 | False | None | None | False | None | False | 68864.1135 | 0 | 2994712 | 99572 | None | V-2 I no 8.1.2 P no 41 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement:6 fine sand) including rounding off corners wherever required smoothrendering, providing and removing scaffolding, including cost of materials,labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 253.05 | 253.05 | 43.68 | False | None | None | False | None | False | 11053.224 | 0 | 2994713 | 99572 | None | V-2 I no 8.8 P no 42 | Providing 18 mm cement plaster in two coats under layer 12 mm thickcement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finishedwith a top layer 6 mm thick cement plaster with cement mortar 1:6 (1cement : 6 fine sand) to brick masonry including rounding off cornerswherever required smooth rendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specificationsand as per directions of Engineer-in-charge. | Sqm | 389.55 | 389.55 | 34.14 | False | None | None | False | None | False | 13299.237 | 0 | 2994714 | 99572 | None | V-2 I no 8.19.1 P no 44 | Providing Flush/ Ruled pointing: Pointing on stone work with cementmortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining,including cost of materials, labour, curing as per specifications and asper directions of Engineer-in-charge | Sqm | 267.75 | 267.75 | 6.22 | False | None | None | False | None | False | 1665.405 | 0 | 2994715 | 99572 | None | V-2 8.22 44 | Providing lime wash on walls with one coat with lime of approved quality to give an even shade, including cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 10.5 | 10.5 | 43.68 | False | None | None | False | None | False | 458.64 | 0 | 2994716 | 99572 | None | V-2 9.11 60 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. | Sqm | 933.45 | 933.45 | 10.46 | False | None | None | False | None | False | 9763.887 | 0 | 2994717 | 99572 | None | V-2 10.14 71 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. | Sqm | 1161.3 | 1161.3 | 33.6 | False | None | None | False | None | False | 39019.68 | 0 | 2994718 | 99572 | None | V-2 9.23 63 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent.e. | Sqm | 2589.3 | 2589.3 | 3.0 | False | None | None | False | None | False | 7767.9 | 0 | 2994719 | 99572 | None | V-2 12.54 104 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm ong brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. | m | 333.9 | 333.9 | 12.0 | False | None | None | False | None | False | 4006.8 | 0 | 2994720 | 99572 | None | V-2 12.55.1 106 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. -do- with both side prelam | Sqm | 2484.3 | 2484.3 | 3.78 | False | None | None | False | None | False | 9390.654 | 0 | 2994721 | 99572 | None | V-2 11.11.1 79 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and 12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). | Kg | 155.4 | 155.4 | 11.34 | False | None | None | False | None | False | 1762.236 | 0 | 2994722 | 99572 | None | V-2 8.27 45 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 55.65 | 55.65 | 18.08 | False | None | None | False | None | False | 1006.152 | 0 | 2994723 | 99572 | None | V-2 8.28 45 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 93.45 | 93.45 | 18.08 | False | None | None | False | None | False | 1689.576 | 0 | 2994724 | 99572 | None | V-2 8.30 46 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 182.7 | 182.7 | 40.36 | False | None | None | False | None | False | 7373.772 | 0 | 2994725 | 99572 | None | V-2 11.34B 86 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. | Kg | 192.15 | 192.15 | 11.34 | False | None | None | False | None | False | 2178.981 | 0 | 2994726 | 99572 | None | V-2 12.61 105 | Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete. | Nos | 1039.5 | 1039.5 | 2.0 | False | None | None | False | None | False | 2079.0 | 0 | 2994727 | 99572 | None | V-2 12.74.1 107 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm | Nos | 107.1 | 107.1 | 6.0 | False | None | None | False | None | False | 642.6 | 0 | 2994728 | 99572 | None | V-2 12.73.1 107 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : | Each | 46.2 | 46.2 | 4.0 | False | None | None | False | None | False | 184.8 | 0 | 2994729 | 99572 | None | V-2 12.72 107 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : | Each | 86.1 | 86.1 | 2.0 | False | None | None | False | None | False | 172.2 | 0 |
| 1710222698000 | 1 | None | None | Buildings | Construction of Toilet Block water supply | 174678.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2994730 | 99573 | None | V-2 14.1.1 131 | Providing and fixing water closet squatting pan (Indian type W.C. pan )with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests | Each | 5128.2 | 5128.2 | 1.0 | False | None | None | False | None | False | 5128.2 | 0 | 2994731 | 99573 | None | V-2 14.5.1 132 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Single half stall urinal with 5 litre P.V.C. automatic flushing cistern | Each | 9074.1 | 9074.1 | 2.0 | False | None | None | False | None | False | 18148.2 | 0 | 2994732 | 99573 | None | V-2 13.34 123 | Providing and placing on Terrace ( at all floor levels) polyethylene water storage tanks IS:12701 marked with cover and suitable locking arrangement and making holes for inlet, outlet and overflow pipes but without fittings and base support of tanks. | l | 9.45 | 9.45 | 500.0 | False | None | None | False | None | False | 4725.0 | 0 | 2994733 | 99573 | None | V-2 13.31.2 122 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm nominal dia Pipes | m | 254.1 | 254.1 | 140.0 | False | None | None | False | None | False | 35574.0 | 0 | 2994734 | 99573 | None | V-2 13.31.1 122 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 15 mm nominal dia Pipes | m | 191.1 | 191.1 | 30.0 | False | None | None | False | None | False | 5733.0 | 0 | 2994735 | 99573 | None | V-2 13.58 127 | Providing and fixing PVC (S.W.R) Gully Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete | Each | 363.3 | 363.3 | 2.0 | False | None | None | False | None | False | 726.6 | 0 | 2994736 | 99573 | None | V-2 13.59 127 | Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete | Each | 231.0 | 231.0 | 2.0 | False | None | None | False | None | False | 462.0 | 0 | 2994737 | 99573 | None | V-5 10.2.4 114 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: 160MM DIA | m | 604.8 | 604.8 | 100.0 | False | None | None | False | None | False | 60480.0 | 0 | 2994738 | 99573 | None | V-2 13.14 119 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 g. | Nos | 888.3 | 888.3 | 4.0 | False | None | None | False | None | False | 3553.2 | 0 | 2994739 | 99573 | None | V-2 14.7.1 132 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps | Each | 3236.1 | 3236.1 | 2.0 | False | None | None | False | None | False | 6472.2 | 0 | 2994740 | 99573 | None | V-5 16.9 191 | Constructing brick masonry chamber of internal dimension 600x600 mm and depth of 600 mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150 mm thick with 1:3:6, lastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75 mm thick for fixing CI cover & frame etc. excluding the cost of CI frame and cover. | Each | 5726.7 | 5726.7 | 4.0 | False | None | None | False | None | False | 22906.8 | 0 | 2994741 | 99573 | None | V-5 16.23.2 196 | Providing and fixing SFRC frame and cover conforming to IS 12592 (part-I)-1988 and IS 12592 (part-II)- 1991 with latest amendment, including cutting slabs to the required size for the opening and fixing the cover in C.C. 1:2:4 and C.M. 1:3 plastering 20 mm thick to all exposed faces, curing for 10 days with all lead and lift with appurtenances. complete | Set | 2692.2 | 2692.2 | 4.0 | False | None | None | False | None | False | 10768.8 | 0 |
| 1710222698000 | 1 | None | None | Buildings | Construction of Toilet Block Electrification work | 65477.18 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2994742 | 99574 | None | ELE P-1 1.2,1 Pg.02 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary - 19/20mm dia 2mm thick | Mtr | 66.0 | 66.0 | 30.0 | False | None | None | False | None | False | 1980.0 | 0 | 2994743 | 99574 | None | ELE P-1 , It.No.1.3.1,Pg.02 | Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. - 19/20mm dia 2mm thick | Mtr | 68.0 | 68.0 | 30.0 | False | None | None | False | None | False | 2040.0 | 0 | 2994744 | 99574 | None | ELE P-1 , It.No.2.1.1 Pg.05 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP B - Short point upto 3Mtr from tapping point to out let via switch | Point | 285.0 | 285.0 | 5.0 | False | None | None | False | None | False | 1425.0 | 0 | 2994745 | 99574 | None | ELE P-1 , It.No.2.1.2 Pg.05 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP B - Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch | Point | 394.0 | 394.0 | 5.0 | False | None | None | False | None | False | 1970.0 | 0 | 2994746 | 99574 | None | ELE P-1 , It.No.2.1.3 Pg.05 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP B - Long point above 6Mtr upto 10Mtr from tapping point to out let via switch | Point | 570.0 | 570.0 | 6.0 | False | None | None | False | None | False | 3420.0 | 0 | 2994747 | 99574 | None | ELE P-1 It.No.2.3.2, Pg.05 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper conductor single core wire in open or concealed system of wiring as per IS-694:1990 & confirming to GTP of GROUP -B. - 1.5 sqmm | Mtr | 26.0 | 26.0 | 70.0 | False | None | None | False | None | False | 1820.0 | 0 | 2994748 | 99574 | None | ELE P-1 It.No.2.3.3, Pg.05 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper conductor single core wire in open or concealed system of wiring as per IS-694:1990 & confirming to GTP of GROUP -B. - 2.5 sqmm | Mtr | 42.0 | 42.0 | 70.0 | False | None | None | False | None | False | 2940.0 | 0 | 2994749 | 99574 | None | ELE P-1 It.No.1.6.3,Pg.03 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete. -10"x7"x3" (254x178x76mm), | Each | 112.0 | 112.0 | 5.0 | False | None | None | False | None | False | 560.0 | 0 | 2994750 | 99574 | None | ELE P-1 ,It No.3.8,Pg.09 | Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc., and fixing on existing wooden or metal box using N.F. screws. | Sq CM | 0.41 | 0.41 | 1000.0 | False | None | None | False | None | False | 410.0 | 0 | 2994751 | 99574 | None | ELE P-1 It.No.3.14.1, Pg.10 | Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board. GROUP A - 6Amps SP Switch | Each | 55.0 | 55.0 | 7.0 | False | None | None | False | None | False | 385.0 | 0 | 2994752 | 99574 | None | ELE P-1 ,It. No.3.14.7, Pg.10 | Supplying and fixing PBBC/Bakelite straight or slant batten holder and wiring with 60w/230 Vts lamps | Each | 74.0 | 74.0 | 6.0 | False | None | None | False | None | False | 444.0 | 0 | 2994753 | 99574 | None | ELE P-1 , It.No.11.3.2, Pg. 34 | Supplying patti type fluorescent tube light fitting of 4' -suitable for 28 watts fluorescent tube fitting, made out of M.S. Sheet and stove enameled with HF Electronic Ballast , locking type brass contact holders mounted on double fold type sheet base fully wired for use on 230 Vts AC . Supply including T5 lamp | Each | 740.0 | 740.0 | 3.0 | False | None | None | False | None | False | 2220.0 | 0 | 2994754 | 99574 | None | ELE P-1 , It.No.13.7.1,Pg. 56 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. - On wall / ceiling / Rafter / Girders | Nos | 122.0 | 122.0 | 3.0 | False | None | None | False | None | False | 366.0 | 0 | 2994755 | 99574 | None | ELE P-1 It.No.11.8.2 , Pg.36 | Supply of Horizontal type Street light fluorescent fitting suitable for single/twin lamp of 24W/28W FTL T5 lamp. Housing shall be with pressure die cast aluminum with UV Protected clear acrylic diffuser with thermoformed & CRCA gear tray, push fit poly carbonate lamp holder, low loss high frequency electronic ballast with IP 54 protection. - 2x4'-28Watts | Each | 3651.0 | 3651.0 | 1.0 | False | None | None | False | None | False | 3651.0 | 0 | 2994756 | 99574 | None | ELE P-1 , It.No.13.7.2, Pg.56 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clampsFixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps., Using necessary length of G.I. chain. | Each | 263.0 | 263.0 | 1.0 | False | None | None | False | None | False | 263.0 | 0 | 2994757 | 99574 | None | ELE P-1 , It.No.5.44.1,Pg.21 | Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. - 300mmx300mmx214mm. | Each | 4512.0 | 4512.0 | 1.0 | False | None | None | False | None | False | 4512.0 | 0 | 2994758 | 99574 | None | ELE P-1 , It.No.5.18.1, Pg.17 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. - 6-32Amps SP | Each | 415.0 | 415.0 | 1.0 | False | None | None | False | None | False | 415.0 | 0 | 2994759 | 99574 | None | ELE P-1 ,It.No.5.18.5, Pg.17 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. - 50-63Amps DP | Each | 1102.0 | 1102.0 | 1.0 | False | None | None | False | None | False | 1102.0 | 0 | 2994760 | 99574 | None | ELE P-1 ,It.No.5.20.4,Pg.18 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board. - 32-40A 2 pole | Each | 4559.0 | 4559.0 | 1.0 | False | None | None | False | None | False | 4559.0 | 0 | 2994761 | 99574 | None | ELE P-1 ,It.No.5.30, Pg.19 | Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter | Each | 1380.0 | 1380.0 | 1.0 | False | None | None | False | None | False | 1380.0 | 0 | 2994762 | 99574 | None | ESCOM P-3 212 It.No.32.02, Pg.13 | Supplying of 1.1 KV LT UG cable having aluminum conductor PVC insulated, extruded inner sheathed, galvanized, steel strip (except 2CX10Sq.mm wire armoured) confirming to IS-3975:1990 (No. of Strip indicated in GTP) & extruded PVC outer sheathed armoured cable with specified IS-1554 Part-1:1988 & confirming to GTP of GROUP-A. - 2 core 10 sqmm | Kms | 79232.0 | 79232.0 | 0.07 | False | None | None | False | None | False | 5546.24 | 0 | 2994763 | 99574 | None | ESCOM P-3 212 It.No.32.05, Pg.13 | Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required.In existing trench/duct. - 6 sqmm to 16 sqmm | Kms | 141842.0 | 141842.0 | 0.07 | False | None | None | False | None | False | 9928.94 | 0 | 2994764 | 99574 | None | Vol-1 I.no 1.6.1 Pg.no 06 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m | m | 484.0 | 484.0 | 20.0 | False | None | None | False | None | False | 9680.0 | 0 | 2994765 | 99574 | None | Vol-1 I.no 1.10 Pg.no 07 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications | Cum | 160.0 | 160.0 | 12.0 | False | None | None | False | None | False | 1920.0 | 0 | 2994766 | 99574 | None | ELEBESCOM P-3 51.04 23 | Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified | Nos | 2172.0 | 2172.0 | 1.0 | False | None | None | False | None | False | 2172.0 | 0 | 2994767 | 99574 | None | ELEBESCOM P-3 51.05 23 | Bentonite clay slurry for earthing in 50 Kg Bag | Nos | 368.0 | 368.0 | 1.0 | False | None | None | False | None | False | 368.0 | 0 |
| 1710222698000 | 1 | None | None | Buildings | Providing Concrete Flooring | 4324683.13 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2994768 | 99575 | None | V-3 3.7 17 | Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and hen compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction. | Cum | 110.25 | 110.25 | 576.52 | False | None | None | False | None | False | 63561.33 | 0 | 2994769 | 99575 | None | V-1 1.14.1 8 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 107.1 | 107.1 | 75.0 | False | None | None | False | None | False | 8032.5 | 0 | 2994770 | 99575 | None | V-3 3.6 P No 17 | Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2 | Cum | 517.65 | 517.65 | 599.02 | False | None | None | False | None | False | 310082.703 | 0 | 2994771 | 99575 | None | V-3 4.17 P No 26 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. | Cum | 2686.95 | 2686.95 | 489.82 | False | None | None | False | None | False | 1316121.849 | 0 | 2994772 | 99575 | None | Vol-3, 16.27 Pg-148 | Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M20 (Grade), coarse and fine aggregates conforming to IS:383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, , primer, sealant , curing of concrete slabs for 14-days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work. | Cum | 6692.7 | 6692.7 | 392.5 | False | None | None | False | None | False | 2626884.75 | 0 |
| 1710222699000 | 1 | None | None | Buildings | Construction of Platform, VIP Entrance Steps & Providing Railing to Stage & Steps | 1069041.25 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2994773 | 99576 | None | V-1 1.14.1 8 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 107.1 | 107.1 | 6.01 | False | None | None | False | None | False | 643.671 | 0 | 2994774 | 99576 | None | V-1 2.1.2 15 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 1.1 | False | None | None | False | None | False | 6541.92 | 0 | 2994775 | 99576 | None | V-2 5.2 9 | Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6948.9 | 6948.9 | 4.72 | False | None | None | False | None | False | 32798.808 | 0 | 2994776 | 99576 | None | V-2 5.4 9 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 9.22 | False | None | None | False | None | False | 61851.909 | 0 | 2994777 | 99576 | None | V-1 1.8 7 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 497.7 | 497.7 | 62.46 | False | None | None | False | None | False | 31086.342 | 0 | 2994778 | 99576 | None | V-2 8.19.1 44 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge. | Sqm | 267.75 | 267.75 | 19.35 | False | None | None | False | None | False | 5180.9625 | 0 | 2994779 | 99576 | None | V-2 9.24 63 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. | Sqm | 2994.6 | 2994.6 | 169.63 | False | None | None | False | None | False | 507973.998 | 0 | 2994780 | 99576 | None | V-2 12.12 99 | Providing Mathi/Nandi wood frames of doors, windows, clerestorywindows, ventilators and other frames, wrought, framed or assembledincluding making plaster groves (excluding cost of cement concrete and sideclamps ), but including cost of materials, labour, usage charges completeas per specifications | Cum | 130412.1 | 130412.1 | 0.1 | False | None | None | False | None | False | 13041.21 | 0 | 2994781 | 99576 | None | V-2 12.15 100 | Providing and fixing in position fully panelled Mathi/Nandi wood shuttersfor doors with stiles and rails of 40mm. thick with bottom and lock rails180mm wide top rail and stiles 100mm wide as per drawing and panels of25mm thick including cost of materials, labour, usage charges completeas per specifications. (excluding cost of fixtures | Sqm | 7241.85 | 7241.85 | 5.04 | False | None | None | False | None | False | 36498.924 | 0 | 2994782 | 99576 | None | V-2 12.51 104 | Fixing of door frame in an existing opening including embedding frame infloor and walls after cutting masonry for holdfasts for embedding holdfastin cement concrete 1:3:6 of 20mm and down size granite metal paintingtwo coats of coal tar to sides of frame, making good the damages to wallsand floor as required and disposal of the debris with lead upto 50 m.including cost of materials, labour charges, complete as per specifications. | Sqm | 1066.8 | 1066.8 | 2.0 | False | None | None | False | None | False | 2133.6 | 0 | 2994783 | 99576 | None | V-2 11.28 83 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 593.25 | 593.25 | 548.64 | False | None | None | False | None | False | 325480.68 | 0 | 2994784 | 99576 | None | V-2 11.25.2 84 | Providing and fixing Steel work welded in built up sections/ framedwork, including cutting, hoisting, fixing in position and applying a primingcoat of approved steel primer using structural steel etc. as required. Ingratings, frames, guard bar, ladder, railings, brackets, gates and similarworks including cost of materials, labour, usage charges of machinerycomplete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 142.8 | 142.8 | 183.75 | False | None | None | False | None | False | 26239.5 | 0 | 2994785 | 99576 | None | V-2 8.33.3 46 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 145.95 | 145.95 | 122.56 | False | None | None | False | None | False | 17887.632 | 0 | 2994786 | 99576 | None | V-2 8.28 45 | Finishing walls with water proofing cement paint of required shade :Newwork (Two coats applied @ 4.84 kg/10 m²) to give an even shade afterthoroughly brooming the surface to remove all dirt, dust, mortar dropsand foreign matter including preparing the surface even and sand papersmooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge. | Sqm | 93.45 | 93.45 | 18.0 | False | None | None | False | None | False | 1682.1 | 0 |
| 1710222699000 | 1 | None | None | Buildings | Compound Wall | 715045.22 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2994787 | 99577 | None | V-1 1.14 151 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usageof machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 107.1 | 107.1 | 7.78 | False | None | None | False | None | False | 833.238 | 0 | 2994788 | 99577 | None | V-1 2.1.2 15 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) | Cum | 5947.2 | 5947.2 | 1.68 | False | None | None | False | None | False | 9991.296 | 0 | 2994789 | 99577 | None | V-1 1.8 7 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 497.7 | 497.7 | 14.47 | False | None | None | False | None | False | 7201.719 | 0 | 2994790 | 99577 | None | V-1 2.2.1 15 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6601.35 | 6601.35 | 1.94 | False | None | None | False | None | False | 12806.619 | 0 | 2994791 | 99577 | None | Corrigendum-3 Sl.No 1b Pno 02 | Add Formwork, Centering & Scaffolding charges for Foundation Upto Plinth for Footing All types at 3% | Cum | 198.04 | 198.04 | 1.94 | False | None | None | False | None | False | 384.1976 | 0 | 2994792 | 99577 | None | V-1 2.5.1 17 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregatesas per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6961.5 | 6961.5 | 0.38 | False | None | None | False | None | False | 2645.37 | 0 | 2994793 | 99577 | None | Corrigendum-3 Sl.No 08 Pno 02 | Add Formwork, Centering & Scaffolding charges for Columns 70% vide Corrigendum - 03 Appendix-I Sl.no 8 P.no 2 | Cum | 4873.05 | 4873.05 | 0.38 | False | None | None | False | None | False | 1851.759 | 0 | 2994794 | 99577 | None | V-1 2.5.1 17 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregatesas per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6961.5 | 6961.5 | 2.07 | False | None | None | False | None | False | 14410.305 | 0 | 2994795 | 99577 | None | Corrigendum-3 Sl.No 1a Pno 2. | Add Formwork, Centering & Scaffolding charges forPlinth Beam of Buildings 50% vide Corrigendum - 03 Appendix-I Sl.no 1a P.no 2 | Cum | 3480.75 | 3480.75 | 2.07 | False | None | None | False | None | False | 7205.1525 | 0 | 2994796 | 99577 | None | V-1 2.5.1 17 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregatesas per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6961.5 | 6961.5 | 1.27 | False | None | None | False | None | False | 8841.105 | 0 | 2994797 | 99577 | None | Corrigendum-3 Sl.No 08 Pno 02 | Add Formwork, Centering & Scaffolding charges for Columns 70% vide Corrigendum - 03 Appendix-I Sl.no 8 P.no 2 | Cum | 4873.05 | 4873.05 | 1.27 | False | None | None | False | None | False | 6188.7735 | 0 | 2994798 | 99577 | None | V-1 2.11A 18 | Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | t | 93929.85 | 93929.85 | 0.3 | False | None | None | False | None | False | 28178.955 | 0 | 2994799 | 99577 | None | V-2 6.32 14 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications | Sqm | 1375.5 | 1375.5 | 112.64 | False | None | None | False | None | False | 154936.32 | 0 | 2994800 | 99577 | None | V-2 8.1.1 41 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 267.75 | 267.75 | 266.9 | False | None | None | False | None | False | 71462.475 | 0 | 2994801 | 99577 | None | V-2 8.30 46 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 182.7 | 182.7 | 266.9 | False | None | None | False | None | False | 48762.63 | 0 | 2994802 | 99577 | None | V-2 8.29 45 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 297.15 | 297.15 | 1142.0 | False | None | None | False | None | False | 339345.3 | 0 |
| 1710222699000 | 1 | None | None | Buildings | Plastering to Gallery | 200690.7 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2994803 | 99578 | None | V-2 8.27 45 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 55.65 | 55.65 | 842.0 | False | None | None | False | None | False | 46857.3 | 0 | 2994804 | 99578 | None | V-2 8.30 46 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 182.7 | 182.7 | 842.0 | False | None | None | False | None | False | 153833.4 | 0 |
| 1710222699000 | 1 | None | None | Buildings | Providing Roof Sheet Grid Ceiling | 1584488.08 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2994805 | 99579 | None | V-2 11.16.2 Pg. 82 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Kg | 154.35 | 154.35 | 3092.57 | False | None | None | False | None | False | 477338.1795 | 0 | 2994806 | 99579 | None | V-1 1.8 Pg. 07 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with alllifts and lead, transportation to site, spreading, grading to required slope andcompacting to meet the requirement complete as per specifications, includingcost of labour,rolling,water,all materials,usage& all other appurtenaces requiredto complete the work. | Cum | 497.7 | 497.7 | 76.8 | False | None | None | False | None | False | 38223.36 | 0 | 2994807 | 99579 | None | V-2 7.1.1 Pg. 21 | Providing & fixing corrugated G.S. sheet roofing including vertical /curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpetwashers filled with white lead, including a coat of approved steel primerand two coats of approved paint on overlapping of sheets complete asper design drawings (up to any pitch in horizontal/ vertical or curvedsurfaces), excluding the cost of purlins, rafters and trusses and includingcutting to size and shape wherever required as per the direction ofEngineer in charge. 0.63 mm thick with zinc coating not less than 275 g/ m² | Sqm | 922.95 | 922.95 | 162.0 | False | None | None | False | None | False | 149517.9 | 0 | 2994808 | 99579 | None | V-2 7.66 Pg. 37 | Providing Fixing of High Acoustical False Ceiling having NRC (Noise Reduction Coefficient) 0.90 (minimum) using Integral Densified edged EcoFriendly Fully Perforated Lightweight Calcium Silicate False Ceiling Tileswith Suitable to Modular Grid Size of 600x600mm with PPGi Slimline profileBalck/White reveal t15 Grid system for Auditoriums, Community halls,Lecture Halls, Airports, Offices, Factories and All other High Acoustics requiredbuildings.The Fully Perforated Lightweight Calcium Silicate False Ceiling tiles shallbe made from Non Cementitious Hydrated Calcium Silicate Slurry/Mixture,Reinforced recycled material with fibers and natural fillers. Free fromFormaldehyde and other harmful materials. Doesn't contain any toxicingrediants. The thickness of tiles should be 15mm at all around the edgeresting portion with integral densified edge and 10mm thick at the quadrant.The tiles should have fiber glass fleece on rear side along with backing of 50mmthick rockwool slabs of density 48kg/m3 to achieve NRC 0.9 (Minimum). The tiles should have Humidity Resistance (RH) of 100percent, Water Resistance,Non Combustible as per BS 476 Part 4 Fire Performance Fire Propagationas per BS 476 Part-6, Class 1 for Surface Spread of Flame as per BS 476 Part 7, Class A or Class 1 as per ASTM E 84, Thermal Conductivity K 0.048 to0.052 w/m K as per ECBC code 2007 Size of the tile is 595x595mm, Density of tile should be 450 kg/m3 density all around on edge resting portion and350kg/m3 density at the Quadrant, Light Reflectance 85%, Weight of thetile is 5-5.5 kg/m2 and Suitable for Green Building application with InOrganicRecycled content of 50% and meets the GRIHA norms under the categories:GRIHA V.2015 criterion:11&12, GRIHA V.3 criterion: 17&29 and SVAGRIHAcriterion:12.The tiles Shall be laid on 15mm wide Polyester Powder Coated Galvanized Iron(PPGI) Slimline Profile Black/White reveal T-Sections Flanges colour whitehaving rotary stitching double webbed on all T sections. The framework shallcomprise of Main T runner with a web height of 38mm and 1200mm & 600mmCross Tees with a web height of 38mm having sheet thickness of 0.4mm. The T sections should have Galvanizing of 120 g/m2 and need to be installedwith Suspension system consisting of 12x50mm long dash fastners, Z cleat25x37x25x1.6mm with pre cut hole on both 25mm flange to accomdatethe 6mm dia bolt of the fasterner on one flange and 6mm fully threadedhanger rod uptom 1000mm length on the other. L-shape level adjuster of size76x25x1.6mm to be fixed with T grid main runner. The entire grid rests on theperphery on a pre coated GI wall angle of size 15x20mm of sheet thickness0.40mm of length 3000mm to be fixed on periphery wall/partition withthe help of plastic rawl plugs at 450mm center to centerand 40mm long s.sscrews. The work shall be carried out as per specifications, drawings and asper direction of Engineer in Charge. | Sqm | 2542.05 | 2542.05 | 361.68 | False | None | None | False | None | False | 919408.644 | 0 |
| 1710222699000 | 1 | None | None | Buildings | Electrification & High Mast Light | 642796.52 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2994809 | 99580 | None | Vol-6.Chapter-1.It No - 1.1.2.Page No.2of105 | Open Conduit System Supplying heavy gauge PVC conduit pipe 25mm dia 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. | m | 81.0 | 81.0 | 100.0 | False | None | None | False | None | False | 8100.0 | 0 | 2994810 | 99580 | None | Vol-6.Chapter-1.It No - 1.1.3.Page No.2of105 | Open Conduit System Supplying heavy gauge PVC conduit pipe 32mm dia 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. | m | 106.0 | 106.0 | 80.0 | False | None | None | False | None | False | 8480.0 | 0 | 2994811 | 99580 | None | Vol-6.Chapter-1.It No - 1.4.2.Page No.2of105 | Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. - 100x75x65mm | Each | 118.0 | 118.0 | 10.0 | False | None | None | False | None | False | 1180.0 | 0 | 2994812 | 99580 | None | Vol-6.Chapter-1.It No - 1.5.2.Page No.3of105 | Supplying and fixing PVC/metal conduit Deep junction box - 25mm deep junction box | Each | 56.0 | 56.0 | 8.0 | False | None | None | False | None | False | 448.0 | 0 | 2994813 | 99580 | None | Vol-6.Chapter-1.It No - 1.5.3.Page No.3of105 | Supplying and fixing PVC/metal conduit Deep junction box - 32mm deep junction box | Each | 61.0 | 61.0 | 2.0 | False | None | None | False | None | False | 122.0 | 0 | 2994814 | 99580 | None | Vol-6.Chapter-2.It No -2.1.2.Page No.5 of 105 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A - Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch | Point | 394.0 | 394.0 | 4.0 | False | None | None | False | None | False | 1576.0 | 0 | 2994815 | 99580 | None | Vol-6.Chapter-2.It No -2.1.3.Page No.5 of 105 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A - Long point above 6Mtr upto 10Mtr from tapping point to out let via switch | Point | 570.0 | 570.0 | 6.0 | False | None | None | False | None | False | 3420.0 | 0 | 2994816 | 99580 | None | Vol-6.Chapter-2.It No -2.1.4.Page No.5 of 105 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A - Two outlet in a row, above 3Mtr upto 6Mtr from tapping point to out let via switches | Point | 708.0 | 708.0 | 4.0 | False | None | None | False | None | False | 2832.0 | 0 | 2994817 | 99580 | None | Vol-6.Chapter-2.It No -2.3.2.Page No.5 of 105 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP -A. - 1.5sqmm. | Mtr | 26.0 | 26.0 | 150.0 | False | None | None | False | None | False | 3900.0 | 0 | 2994818 | 99580 | None | Vol-6.Chapter-2.It No -2.3.3.Page No.5 of 105 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP -A. - 2.5sqmm. | Mtr | 42.0 | 42.0 | 200.0 | False | None | None | False | None | False | 8400.0 | 0 | 2994819 | 99580 | None | Vol-6.Chapter-2.It No -2.3.4.Page No.5 of 105 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP -A. - 4.0sqmm. | Mtr | 63.0 | 63.0 | 150.0 | False | None | None | False | None | False | 9450.0 | 0 | 2994820 | 99580 | None | Vol-6.Chapter-3.It No - 3.4.4.Page No.8 of 105 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 6Way | Each | 220.0 | 220.0 | 4.0 | False | None | None | False | None | False | 880.0 | 0 | 2994821 | 99580 | None | Vol-6.Chapter-3.It No - 3.4.5.Page No.8 of 105 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 8Way | Each | 261.0 | 261.0 | 6.0 | False | None | None | False | None | False | 1566.0 | 0 | 2994822 | 99580 | None | Vol-6.Chapter-3.It No - 3.4.6.Page No.8 of 105 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone- 10-12Way | Each | 319.0 | 319.0 | 4.0 | False | None | None | False | None | False | 1276.0 | 0 | 2994823 | 99580 | None | Vol-6.Chapter-3.It No - 3.4.7.Page No.8 of 105 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone wall - 16-18Way | Each | 363.0 | 363.0 | 2.0 | False | None | None | False | None | False | 726.0 | 0 | 2994824 | 99580 | None | Vol-6.Chapter-3.It No - 3.5.4.Page No.8 of 105 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 6 Module | Each | 234.0 | 234.0 | 4.0 | False | None | None | False | None | False | 936.0 | 0 | 2994825 | 99580 | None | Vol-6.Chapter-3.It No - 3.5.5.Page No.8 of 105 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 8Module | Each | 284.0 | 284.0 | 6.0 | False | None | None | False | None | False | 1704.0 | 0 | 2994826 | 99580 | None | Vol-6.Chapter-3.It No - 3.5.6.Page No.8 of 105 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 10-12Module | Each | 344.0 | 344.0 | 4.0 | False | None | None | False | None | False | 1376.0 | 0 | 2994827 | 99580 | None | Vol-6.Chapter-3.It No - 3.5.7.Page No.8 of 105 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 16 Module | Each | 397.0 | 397.0 | 2.0 | False | None | None | False | None | False | 794.0 | 0 | 2994828 | 99580 | None | Vol-6.Chapter-3.It No - 3.6.1.Page No.9 of 105 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps one way switch. | Each | 102.0 | 102.0 | 10.0 | False | None | None | False | None | False | 1020.0 | 0 | 2994829 | 99580 | None | Vol-6.Chapter-3.It No - 3.6.4.Page No.9 of 105 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 Stepped fan regulator. | Each | 357.0 | 357.0 | 4.0 | False | None | None | False | None | False | 1428.0 | 0 | 2994830 | 99580 | None | Vol-6.Chap-3.It No 3.6.7.Page No.9 of 105 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 16Amps one way switch. | Each | 180.0 | 180.0 | 10.0 | False | None | None | False | None | False | 1800.0 | 0 | 2994831 | 99580 | None | Vol-6.Chapt-3.It No 3.6.3.Page No.9 of 105 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps 3way socket. | Each | 171.0 | 171.0 | 10.0 | False | None | None | False | None | False | 1710.0 | 0 | 2994832 | 99580 | None | Vol-6.Chapt-3.It No3.6.10.Page No.9 of 105 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6/16Amps universal socket. | Each | 236.0 | 236.0 | 6.0 | False | None | None | False | None | False | 1416.0 | 0 | 2994833 | 99580 | None | Vol-6.Chapt-5.It No 5.7.3.Pg No.14 of 105 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 63Amps | Each | 401.0 | 401.0 | 2.0 | False | None | None | False | None | False | 802.0 | 0 | 2994834 | 99580 | None | Vol-6.Chapt-5.It No 5.8.1.Pg No.15 of 105 | Supplying of Switch disconnector fuse unit (TPN) HRC type (but without HRC fuses). With AC-23A duty and as per IS-13947. 63Amps | Each | 2312.0 | 2312.0 | 1.0 | False | None | None | False | None | False | 2312.0 | 0 | 2994835 | 99580 | None | Vol-6.Chapter-5.It No - 5.15.1.Page No.17 of 105 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics) THREE POLE 100Amps 25kA. | Each | 6086.0 | 6086.0 | 1.0 | False | None | None | False | None | False | 6086.0 | 0 | 2994836 | 99580 | None | Vol-6.Chapter-5.It No - 5.18.3.Page No.17of105 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63Amps SP | Each | 811.0 | 811.0 | 4.0 | False | None | None | False | None | False | 3244.0 | 0 | 2994837 | 99580 | None | Vol-6.Chapter-5.It No - 5.18.6.Page No.17of105 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63Amps DP | Each | 1102.0 | 1102.0 | 2.0 | False | None | None | False | None | False | 2204.0 | 0 | 2994838 | 99580 | None | Vol-6.Chapter-5.It No - 5.20.10.Page No.13 of 47 | Supplying,fixingandwiringResidualcurrentcircuitbreaker(RCCB)240/450V upto 300mA sensitivity on existing wood/ panel board. 63 Amps 4 pole | Each | 5545.0 | 5545.0 | 1.0 | False | None | None | False | None | False | 5545.0 | 0 | 2994839 | 99580 | None | Vol-6.Chapt-5.It No - 5.35.Pg No.19 of 105 | Supplying,fixingandwiringElectronicTrivectorMeter(ETV)5to32/63Athreephase4wirewholecurrentclass-1AccuracyEnergyMeter. | Each | 5705.0 | 5705.0 | 1.0 | False | None | None | False | None | False | 5705.0 | 0 | 2994840 | 99580 | None | Vol-6.Chapter-5.It No - 5.44.1.Pg No.21 of 105 | Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 300mmx300mmx214mm | Each | 4512.0 | 4512.0 | 1.0 | False | None | None | False | None | False | 4512.0 | 0 | 2994841 | 99580 | None | Vol-6.Chapter-6.It No - 6.3.1.Page No.30 of 105 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200mm) Regular model | Each | 2984.0 | 2984.0 | 6.0 | False | None | None | False | None | False | 17904.0 | 0 | 2994842 | 99580 | None | Vol-6.Chapter-6.It No - 6.5.2.Page No.30 of 105 | Supplying wall mounting fan suitable to operate at singlephase 230v A.C. supply 400mm Sweep | Each | 3212.0 | 3212.0 | 2.0 | False | None | None | False | None | False | 6424.0 | 0 | 2994843 | 99580 | None | Vol-6.Chapter-11.It No - 11.3.2.Pg No.43 of 105 | Supplying of ......feet - PVC Batten with integrated LED tube.....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED Light fighting 1 x4'- 20/22 w | Each | 690.0 | 690.0 | 8.0 | False | None | None | False | None | False | 5520.0 | 0 | 2994844 | 99580 | None | Vol-6.Chapter-13.It No - 13.7.1.Pg No.56 of 105 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders | Each | 122.0 | 122.0 | 6.0 | False | None | None | False | None | False | 732.0 | 0 | 2994845 | 99580 | None | Vol-6.Chapter-13.It No - 13.7.2.Pg No.56 of 105 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. Using necessary length of G.I. chain | Each | 263.0 | 263.0 | 8.0 | False | None | None | False | None | False | 2104.0 | 0 | 2994846 | 99580 | None | Vol-6.Chapter-13.It No - 13.10.Pg No.57 of 105 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 171.0 | 171.0 | 6.0 | False | None | None | False | None | False | 1026.0 | 0 | 2994847 | 99580 | None | Vol-6.Chapter-13.It No -13.11.Pg No.57of105 | Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. | Each | 315.0 | 315.0 | 2.0 | False | None | None | False | None | False | 630.0 | 0 | 2994848 | 99580 | None | ES P3 .Sl 201.I.32.05.Code No.287206.Page No.13.81 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) | Km | 141842.0 | 141842.0 | 0.05 | False | None | None | False | None | False | 7092.1 | 0 | 2994849 | 99580 | None | ES SL .167.Item.No.20.05.Page No 52.81 | Transporting Cable from Store to work spot including loading and unloading (including Crane and other equipment charges if any) LT Cable 2.5 to 25 Sqmm (Single/3.5/4 Core) | Km | 1187.0 | 1187.0 | 0.05 | False | None | None | False | None | False | 59.35 | 0 | 2994850 | 99580 | None | Vol-6.Chapter-2.It No -2.5.2.Page No.6 of 105 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to table 3 class 5 of IS:8130-1984 and (Virgin) PVC insulation and sheathed suitable for working voltage upto 1100Volts as per IS-694:1990 3C X 1.5Sq.mm | Mtr | 72.0 | 72.0 | 96.0 | False | None | None | False | None | False | 6912.0 | 0 | 2994851 | 99580 | None | Vol-6.Chapter-1.It No - 1.1.4.Page No.2of105 | Open Conduit System Supplying heavy gauge PVC conduit pipe 40mm dia 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. | Mtr | 149.0 | 149.0 | 50.0 | False | None | None | False | None | False | 7450.0 | 0 | 2994852 | 99580 | None | Vol-6.Chapter-11.It No- 1.9.3.Page No.46of105 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation.Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material,delivering superior light output. Rated life Burning Hrs 50000hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency130lm/w, nominal CRI75. Luminaire manufacturer should have inhouse facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/Lumileds /Osram make LED Source LED Floodlight 120W | Each | 10757.0 | 10757.0 | 8.0 | False | None | None | False | None | False | 86056.0 | 0 | 2994853 | 99580 | None | Vol-6.Chapter-4.It No - 4.5.1.Page No.13 of 105 | Fabrication, Supplying, Erection, Testing and Commissioning of ……Mtrs long polygon high mast with Single / Multiple telescopic sections having, ( minimum overlap distance of 1.5 times of top section) thickness as per BSEN 10025 grade S 355 JO /ASTM A572-50 steel sheet plate for shaft suitable to withstand a wind velocity of 47 m/sec as per IS 875 part 3(as per GA Drawing).Base plate as per IS 2062/ASTM A572-50. The mast shall be Galvanized in single Hot-dip as per BSEN ISO 1461/ASTM A123 with an average 70 microns as per IS 2629, and welded as per BS 5135 Single L-Seam joint. The mast shall have 2way head frame with die cast LM-6 pulleys, stainless steel axle, Phosphorus Bronze bearing bush press-fitted with separate guides for 2 runs of 5mm dia, stainless steel wire rope of AISI 304grade 7/19-core, (Factor of Safety as per TR no-7). 2.5sqmm EPR insulated PCP sheathed trailing power cable housed inside the bottom shaft of mast with door having locking arrangement. The mast shall have power tool operating on 230/ 415V, 50Hz, 1/3 phases reversible geared motor. The mast shall have lantern of 2 segments, suitable dia with max load carrying capacity as per IS 1239. The mast shall be erected on existing RCC footing. The mast shall be supplied with 3mm thick template, lightning arrester of 1.2m length galvanized pipe with top arrow fitted on top of the head frame cover and GLS type aviation twin lamps fitting with wiring complete. ( excluding foundation) as per technical data. 12Mtrs/12.5Mtrs - Top 100mm and bottom 310 mm dia | Each | 131000.0 | 131000.0 | 1.0 | False | None | None | False | None | False | 131000.0 | 0 | 2994854 | 99580 | None | Vol-6.Chapter-4.It No - 4.6.6.Page No.13 of105 | Supplying, and fixing of Hot dip Galvanized M.S.Bracket suitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. Double Arm Bracket with 2000mm Standard 40/50MM dia | Each | 3800.0 | 3800.0 | 1.0 | False | None | None | False | None | False | 3800.0 | 0 | 2994855 | 99580 | None | Vol-6.Chapter-5.It No - 5.13.3.Page No.11 of 47 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 60-70Amps | Each | 4926.0 | 4926.0 | 1.0 | False | None | None | False | None | False | 4926.0 | 0 | 2994856 | 99580 | None | Vol-6.Chapter-5.It No - 5.18.4.Page No.17 of 105 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 Amps DP | Each | 739.0 | 739.0 | 4.0 | False | None | None | False | None | False | 2956.0 | 0 | 2994857 | 99580 | None | Vol-6.Chapter-5.It No - 5.44.4.Page No.21 of 105 | Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 600mmx600mmx170mm | Each | 14520.0 | 14520.0 | 1.0 | False | None | None | False | None | False | 14520.0 | 0 | 2994858 | 99580 | None | Vol-6.Chapter-5.It No - 5.48.Page No.21of 105 | Supplying and fixing Microprocessor based Electronic timer (without contactor, Din Mounting using necessary bolts, nuts and washers etc.,.) 3-120sec setting. | Each | 4843.0 | 4843.0 | 1.0 | False | None | None | False | None | False | 4843.0 | 0 | 2994859 | 99580 | None | Es P3.Sl 199.I No.32.03.Code No.287205.P No.13.81 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm) | Km | 118004.0 | 118004.0 | 0.1 | False | None | None | False | None | False | 11800.4 | 0 | 2994860 | 99580 | None | ES Part-IV.Sl.No.167.Item.No.20.05.Page No.52.81 | Transporting Cable from Store to work spot including loading and unloading (including Crane and other equipment charges if any) LT Cable 2.5 to 25 Sqmm (Single/3.5/4 Core) | Km | 1187.0 | 1187.0 | 0.1 | False | None | None | False | None | False | 118.7 | 0 | 2994861 | 99580 | None | DSR 2023-24.Vol-1.Item.No.1.6.1.Page No.06 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m | Mtr | 508.2 | 508.2 | 15.0 | False | None | None | False | None | False | 7623.0 | 0 | 2994862 | 99580 | None | DSR 2023-24.Vol-1.Item.No.1.10.Page No.07 | Refilling available earth around trenches/pipelines, cables in layers notexceeding 20 cms in depth, compacting each deposited layer by ramming afterwatering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labourcomplete as per specifications | Cum | 168.0 | 168.0 | 15.0 | False | None | None | False | None | False | 2520.0 | 0 | 2994863 | 99580 | None | Es P3.S 392.I No1.04. .281685.Page No.23 . 81 | Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified | No | 2172.0 | 2172.0 | 2.0 | False | None | None | False | None | False | 4344.0 | 0 | 2994864 | 99580 | None | ES.P-3 SL 392.I No.51.05. .281685.Page No.23 . 81 | Bentoetite Clay Slurry for Earthing in 50kgs Bag | Bag | 368.0 | 368.0 | 2.0 | False | None | None | False | None | False | 736.0 | 0 | 2994865 | 99580 | None | DSR 2014-15,Pg.-101, It No- 15.6.1 | Supply, installation, testing and commissioning of booster amplifier with power handling of 250 to 300 watt RMS 4ohms Dual and 100/70 volt output on bridge mode single channel Rack mountable Specs: frequency response : 20 htz to 20khtz | No | 27550.0 | 27550.0 | 1.0 | False | None | None | False | None | False | 27550.0 | 0 | 2994866 | 99580 | None | DSR 2014-15,Pg.-101, It No- 15.7.1 | Supply, installation, testing and commissioning of 4 to 6 Channel 4 mic/line input mixer with 2/3 band semi parametric eq 2 bus and 2 aux 2 stereo return. | No | 12800.0 | 12800.0 | 1.0 | False | None | None | False | None | False | 12800.0 | 0 | 2994867 | 99580 | None | DSR 2014-15,Pg.-101, It No- 15.8.2 | Supply, installation, testing and commissioning of dual channel 31 band Graphic Equalizer with 31 band Controls on each Channel filters per channel 6db to 12 db. boost/cut multi band manually selectable parametric equalizer dual channel. | No | 18200.0 | 18200.0 | 1.0 | False | None | None | False | None | False | 18200.0 | 0 | 2994868 | 99580 | None | DSR 2014-15,Pg.-101, It No- 15.9.2 | Supply, installation, testing and commissioning of cardioids handheld/collar VHF/UHF Economical wireless microphone Transmitter and receiver with selectable carrier Frequency from VHF/UHF 179-279 MHz 575 MHz to 875 MHz | No | 5300.0 | 5300.0 | 4.0 | False | None | None | False | None | False | 21200.0 | 0 | 2994869 | 99580 | None | DSR 2014-15,Pg.-102, It No- 15.10 | System Racks Supply, installation, testing and commissioning of 19" 20/15U 580 Depth system rack with Front glass door , back door with heavy duty wheels with cable manager and power strip and termination plates for signal and speaker out system. | No | 12800.0 | 12800.0 | 1.0 | False | None | None | False | None | False | 12800.0 | 0 | 2994870 | 99580 | None | DSR 2014-15,Pg.-102, It No- 15.11 | Speaker Cables Supply, installation, testing and commissioning professional grade 2.5 sq mm TIN coated low loss 2 core multi strand Oxidation Free speaker cable including, lead and lifts, loading and unloading, cost of conveyance for all the materials with the accessories | Mtr | 38.0 | 38.0 | 150.0 | False | None | None | False | None | False | 5700.0 | 0 | 2994871 | 99580 | None | DSR 2014-15,Pg.-102, It No- 15.12 | Connectors and I/C Cables Supply, installation, testing and commissioning of professional grade audio connectors for inter connection cables with in the rack and other units as well auditorium as required including charges for labour, lead and lifts, loading and unloading, cost of conveyance for all the materials with the accessories required for completion as per the detailed specifications. Neutrick/SR/Amphenol /nT/MX /Equivalent. | Set | 240.0 | 240.0 | 10.0 | False | None | None | False | None | False | 2400.0 | 0 | 2994872 | 99580 | None | Vol-6.Chapter-11.It No-11.9.1.Page No.46of105 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation.Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material,delivering superior light output. Rated life Burning Hrs 50000hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains,Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency130lm/w,nominal CRI 75. Luminaire manufacturer should have inhouse facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/Lumileds /Osram make LED Source.LED Floodlight 70W | Each | 6768.0 | 6768.0 | 8.0 | False | None | None | False | None | False | 54144.0 | 0 | 2994873 | 99580 | None | PWD Civil SR 2023-24 Vol-1 P.No.06 It.No.1.6.1 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m | Mtr | 508.2 | 508.2 | 15.0 | False | None | None | False | None | False | 7623.0 | 0 | 2994874 | 99580 | None | PWD Civil SR 2023-24 Vol-1 P.No.18 It.No.2.11 h | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / softannealed steel wire and other ancilary operations complete as per drawing andtechnical specification All other type of structures | t | 82961.55 | 82961.55 | 0.034 | False | None | None | False | None | False | 2820.6927 | 0 | 2994875 | 99580 | None | PWD Civil SR 2023-24 Vol-1 P.No.15 It.No.2.1.2 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 2.5 | False | None | None | False | None | False | 14868.0 | 0 | 2994876 | 99580 | None | PWD Civil SR 2023-24 Vol-1 P.No.16 It.No.2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7185.15 | 7185.15 | 3.0 | False | None | None | False | None | False | 21555.45 | 0 | 2994877 | 99580 | None | Appendix-I in Volume-1 ofPg..-111 | Additional for formwork, Centering & Scaffolding for Sl No 9 : Columns As per Appendix-I in Volume-1 of page No.-111 (@ 70% of Revised Finished Rate) | Cum | 5029.61 | 5029.61 | 3.0 | False | None | None | False | None | False | 15088.83 | 0 |
| 1710223046000 | 1 | None | None | Buildings | Balance Work for Construction of Amphi Theater at Raichur City. In Raichur Taluka, Raichur District. Under KKRDB MACRO (GENERAL) For the year 2023-24. Work Code - RCH2317143465 | 10041384.24 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2995191 | 99592 | None | ELE P-1 1.2,1 Pg.02 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary - 19/20mm dia 2mm thick | Mtr | 66.0 | 66.0 | 30.0 | False | None | None | False | None | False | 1980.0 | 0 | 2995107 | 99592 | None | ELE P-1 2.2.1, Pg.05 | Supplying and wiring adopting loop system in the existing PVC conduit/ pipe using copper PVC insulated multistrand 2 x 1.5 sq.mm wire without switch on the existing the matel box the other end of the wires shall be terminated with sufficient loose length in a PVC round block , complete for each outlet Point wiring using class A Materials Short point upto 3 mts from tapping point to out let via switch | Point | 269.0 | 269.0 | 15.0 | False | None | None | False | None | False | 4035.0 | 0 | 2994950 | 99592 | None | V-1 1.14.1 8 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 107.1 | 107.1 | 6.01 | False | None | None | False | None | False | 643.671 | 0 | 2995149 | 99592 | None | V-1 1.14.1 8 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 107.1 | 107.1 | 6.98 | False | None | None | False | None | False | 747.558 | 0 | 2995055 | 99592 | None | V-1 1.14.1 Pg. 8 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth | Cum | 107.1 | 107.1 | 5.0 | False | None | None | False | None | False | 535.5 | 0 | 2994964 | 99592 | None | V-1 1.14 151 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usageof machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 107.1 | 107.1 | 7.78 | False | None | None | False | None | False | 833.238 | 0 | 2994982 | 99592 | None | V-2 11.16.2 Pg. 82 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Kg | 154.35 | 154.35 | 3092.57 | False | None | None | False | None | False | 477338.1795 | 0 | 2995096 | 99592 | None | V-2 13.34 Pg. 12 | Providing and placing on Terrace ( at all floor levels) polyethylene water storage tanks IS:12701 marked with cover and suitable locking arrangement and making holes for inlet, outlet and overflow pipes but without fittings and base support of tanks. | l | 9.45 | 9.45 | 1000.0 | False | None | None | False | None | False | 9450.0 | 0 | 2995179 | 99592 | None | V-2 14.1.1 131 | Providing and fixing water closet squatting pan (Indian type W.C. pan )with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests | Each | 5128.2 | 5128.2 | 1.0 | False | None | None | False | None | False | 5128.2 | 0 | 2994980 | 99592 | None | V-2 8.27 45 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 55.65 | 55.65 | 842.0 | False | None | None | False | None | False | 46857.3 | 0 | 2995217 | 99592 | None | V-3 3.7 17 | Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and hen compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction. | Cum | 110.25 | 110.25 | 576.52 | False | None | None | False | None | False | 63561.33 | 0 | 2994986 | 99592 | None | Vol-6.Chapter-1.It No - 1.1.2.Page No.2of105 | Open Conduit System Supplying heavy gauge PVC conduit pipe 25mm dia 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. | m | 81.0 | 81.0 | 100.0 | False | None | None | False | None | False | 8100.0 | 0 | 2995192 | 99592 | None | ELE P-1 , It.No.1.3.1,Pg.02 | Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. - 19/20mm dia 2mm thick | Mtr | 68.0 | 68.0 | 30.0 | False | None | None | False | None | False | 2040.0 | 0 | 2995108 | 99592 | None | ELE P-1 2.2.2 Pg.05 | Supplying and wiring adopting loop system in the existing PVC conduit/ pipe using copper PVC insulated multistrand 2 x 1.5 sq.mm wire without switch on the existing the matel box the other end of the wires shall be terminated with sufficient loose length in a PVC round block , complete for each outlet Point wiring using class A Materials Medium point above 3 mts upto 6mts from tapping point to outlet via switch | Point | 379.0 | 379.0 | 20.0 | False | None | None | False | None | False | 7580.0 | 0 | 2994983 | 99592 | None | V-1 1.8 Pg. 07 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with alllifts and lead, transportation to site, spreading, grading to required slope andcompacting to meet the requirement complete as per specifications, includingcost of labour,rolling,water,all materials,usage& all other appurtenaces requiredto complete the work. | Cum | 497.7 | 497.7 | 76.8 | False | None | None | False | None | False | 38223.36 | 0 | 2994951 | 99592 | None | V-1 2.1.2 15 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 1.1 | False | None | None | False | None | False | 6541.92 | 0 | 2994965 | 99592 | None | V-1 2.1.2 15 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) | Cum | 5947.2 | 5947.2 | 1.68 | False | None | None | False | None | False | 9991.296 | 0 | 2995218 | 99592 | None | V-1 1.14.1 8 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 107.1 | 107.1 | 75.0 | False | None | None | False | None | False | 8032.5 | 0 | 2995056 | 99592 | None | V-1 1.14.1 Pg. 37 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usageof machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 107.1 | 107.1 | 35.98 | False | None | None | False | None | False | 3853.458 | 0 | 2995150 | 99592 | None | V-1 1.23 151 | Providing and filling foundation with granite / trap broken metal 100mm and down size with approved sand including hand packing, ramming watering including cost of all material and labourwith all lead and lift complete as per specification. | Cum | 2816.1 | 2816.1 | 3.49 | False | None | None | False | None | False | 9828.189 | 0 | 2995097 | 99592 | None | V-2 13.32.2 Pg.122 | 13.86 Providing and fixing Chlorinated Poli Vinyl Chloride (CPVC) pipes conforming to IS 15778 having terminal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this including fixing the pipe with clamp at 1.00mtrs spacing . This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications. (Internal)(Concealed work including cutting chasses & good the wall Etc) DSR 2021-22 V-2 13.32.2 | m | 397.95 | 397.95 | 20.0 | False | None | None | False | None | False | 7959.0 | 0 | 2995180 | 99592 | None | V-2 14.5.1 132 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Single half stall urinal with 5 litre P.V.C. automatic flushing cistern | Each | 9074.1 | 9074.1 | 2.0 | False | None | None | False | None | False | 18148.2 | 0 | 2994981 | 99592 | None | V-2 8.30 46 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 182.7 | 182.7 | 842.0 | False | None | None | False | None | False | 153833.4 | 0 | 2994987 | 99592 | None | Vol-6.Chapter-1.It No - 1.1.3.Page No.2of105 | Open Conduit System Supplying heavy gauge PVC conduit pipe 32mm dia 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. | m | 106.0 | 106.0 | 80.0 | False | None | None | False | None | False | 8480.0 | 0 | 2995193 | 99592 | None | ELE P-1 , It.No.2.1.1 Pg.05 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP B - Short point upto 3Mtr from tapping point to out let via switch | Point | 285.0 | 285.0 | 5.0 | False | None | None | False | None | False | 1425.0 | 0 | 2995109 | 99592 | None | ELE P-1 2.2.3 Pg.05 | Supplying and wiring adopting loop system in the existing PVC conduit/ pipe using copper PVC insulated multistrand 2 x 1.5 sq.mm wire without switch on the existing the matel box the other end of the wires shall be terminated with sufficient loose length in a PVC round block , complete for each outlet Point wiring using class A MaterialsLong point above 6 mts upto 10 mts from tapping point to outlet via switch | Point | 555.0 | 555.0 | 10.0 | False | None | None | False | None | False | 5550.0 | 0 | 2994966 | 99592 | None | V-1 1.8 7 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 497.7 | 497.7 | 14.47 | False | None | None | False | None | False | 7201.719 | 0 | 2995151 | 99592 | None | V-1 2.1.2 15 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 1.96 | False | None | None | False | None | False | 11656.512 | 0 | 2995057 | 99592 | None | V-1 2.1.2 Pg. 15 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) | Cum | 5947.2 | 5947.2 | 4.97 | False | None | None | False | None | False | 29557.584 | 0 | 2995181 | 99592 | None | V-2 13.34 123 | Providing and placing on Terrace ( at all floor levels) polyethylene water storage tanks IS:12701 marked with cover and suitable locking arrangement and making holes for inlet, outlet and overflow pipes but without fittings and base support of tanks. | l | 9.45 | 9.45 | 500.0 | False | None | None | False | None | False | 4725.0 | 0 | 2994952 | 99592 | None | V-2 5.2 9 | Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6948.9 | 6948.9 | 4.72 | False | None | None | False | None | False | 32798.808 | 0 | 2994984 | 99592 | None | V-2 7.1.1 Pg. 21 | Providing & fixing corrugated G.S. sheet roofing including vertical /curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpetwashers filled with white lead, including a coat of approved steel primerand two coats of approved paint on overlapping of sheets complete asper design drawings (up to any pitch in horizontal/ vertical or curvedsurfaces), excluding the cost of purlins, rafters and trusses and includingcutting to size and shape wherever required as per the direction ofEngineer in charge. 0.63 mm thick with zinc coating not less than 275 g/ m² | Sqm | 922.95 | 922.95 | 162.0 | False | None | None | False | None | False | 149517.9 | 0 | 2995219 | 99592 | None | V-3 3.6 P No 17 | Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2 | Cum | 517.65 | 517.65 | 599.02 | False | None | None | False | None | False | 310082.703 | 0 | 2995098 | 99592 | None | V-5 10.1.1 Pg. 113 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and cmmissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 25mm dia, 10 kg/sqcm & class 5 | m | 50.4 | 50.4 | 20.0 | False | None | None | False | None | False | 1008.0 | 0 | 2994988 | 99592 | None | Vol-6.Chapter-1.It No - 1.4.2.Page No.2of105 | Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. - 100x75x65mm | Each | 118.0 | 118.0 | 10.0 | False | None | None | False | None | False | 1180.0 | 0 | 2995194 | 99592 | None | ELE P-1 , It.No.2.1.2 Pg.05 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP B - Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch | Point | 394.0 | 394.0 | 5.0 | False | None | None | False | None | False | 1970.0 | 0 | 2995110 | 99592 | None | ELE P-1 It.No.3.4.1 Pg.08 | Supplying and flush mounting powder coated/Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 1-2 Way | Each | 138.0 | 138.0 | 10.0 | False | None | None | False | None | False | 1380.0 | 0 | 2994967 | 99592 | None | V-1 2.2.1 15 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6601.35 | 6601.35 | 1.94 | False | None | None | False | None | False | 12806.619 | 0 | 2995182 | 99592 | None | V-2 13.31.2 122 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm nominal dia Pipes | m | 254.1 | 254.1 | 140.0 | False | None | None | False | None | False | 35574.0 | 0 | 2995152 | 99592 | None | V-2 5.2 9 | Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6948.9 | 6948.9 | 3.49 | False | None | None | False | None | False | 24251.661 | 0 | 2995058 | 99592 | None | V-2 5.2 Pg. 9 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6948.9 | 6948.9 | 16.6 | False | None | None | False | None | False | 115351.74 | 0 | 2994953 | 99592 | None | V-2 5.4 9 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 9.22 | False | None | None | False | None | False | 61851.909 | 0 | 2994985 | 99592 | None | V-2 7.66 Pg. 37 | Providing Fixing of High Acoustical False Ceiling having NRC (Noise Reduction Coefficient) 0.90 (minimum) using Integral Densified edged EcoFriendly Fully Perforated Lightweight Calcium Silicate False Ceiling Tileswith Suitable to Modular Grid Size of 600x600mm with PPGi Slimline profileBalck/White reveal t15 Grid system for Auditoriums, Community halls,Lecture Halls, Airports, Offices, Factories and All other High Acoustics requiredbuildings.The Fully Perforated Lightweight Calcium Silicate False Ceiling tiles shallbe made from Non Cementitious Hydrated Calcium Silicate Slurry/Mixture,Reinforced recycled material with fibers and natural fillers. Free fromFormaldehyde and other harmful materials. Doesn't contain any toxicingrediants. The thickness of tiles should be 15mm at all around the edgeresting portion with integral densified edge and 10mm thick at the quadrant.The tiles should have fiber glass fleece on rear side along with backing of 50mmthick rockwool slabs of density 48kg/m3 to achieve NRC 0.9 (Minimum). The tiles should have Humidity Resistance (RH) of 100percent, Water Resistance,Non Combustible as per BS 476 Part 4 Fire Performance Fire Propagationas per BS 476 Part-6, Class 1 for Surface Spread of Flame as per BS 476 Part 7, Class A or Class 1 as per ASTM E 84, Thermal Conductivity K 0.048 to0.052 w/m K as per ECBC code 2007 Size of the tile is 595x595mm, Density of tile should be 450 kg/m3 density all around on edge resting portion and350kg/m3 density at the Quadrant, Light Reflectance 85%, Weight of thetile is 5-5.5 kg/m2 and Suitable for Green Building application with InOrganicRecycled content of 50% and meets the GRIHA norms under the categories:GRIHA V.2015 criterion:11&12, GRIHA V.3 criterion: 17&29 and SVAGRIHAcriterion:12.The tiles Shall be laid on 15mm wide Polyester Powder Coated Galvanized Iron(PPGI) Slimline Profile Black/White reveal T-Sections Flanges colour whitehaving rotary stitching double webbed on all T sections. The framework shallcomprise of Main T runner with a web height of 38mm and 1200mm & 600mmCross Tees with a web height of 38mm having sheet thickness of 0.4mm. The T sections should have Galvanizing of 120 g/m2 and need to be installedwith Suspension system consisting of 12x50mm long dash fastners, Z cleat25x37x25x1.6mm with pre cut hole on both 25mm flange to accomdatethe 6mm dia bolt of the fasterner on one flange and 6mm fully threadedhanger rod uptom 1000mm length on the other. L-shape level adjuster of size76x25x1.6mm to be fixed with T grid main runner. The entire grid rests on theperphery on a pre coated GI wall angle of size 15x20mm of sheet thickness0.40mm of length 3000mm to be fixed on periphery wall/partition withthe help of plastic rawl plugs at 450mm center to centerand 40mm long s.sscrews. The work shall be carried out as per specifications, drawings and asper direction of Engineer in Charge. | Sqm | 2542.05 | 2542.05 | 361.68 | False | None | None | False | None | False | 919408.644 | 0 | 2995220 | 99592 | None | V-3 4.17 P No 26 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. | Cum | 2686.95 | 2686.95 | 489.82 | False | None | None | False | None | False | 1316121.849 | 0 | 2995099 | 99592 | None | V-5 10.1.2 Pg. 113 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and cmmissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 32mm dia., 10 kg/sqcm & class 5 | m | 70.35 | 70.35 | 20.0 | False | None | None | False | None | False | 1407.0 | 0 | 2994989 | 99592 | None | Vol-6.Chapter-1.It No - 1.5.2.Page No.3of105 | Supplying and fixing PVC/metal conduit Deep junction box - 25mm deep junction box | Each | 56.0 | 56.0 | 8.0 | False | None | None | False | None | False | 448.0 | 0 | 2994968 | 99592 | None | Corrigendum-3 Sl.No 1b Pno 02 | Add Formwork, Centering & Scaffolding charges for Foundation Upto Plinth for Footing All types at 3% | Cum | 198.04 | 198.04 | 1.94 | False | None | None | False | None | False | 384.1976 | 0 | 2995195 | 99592 | None | ELE P-1 , It.No.2.1.3 Pg.05 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP B - Long point above 6Mtr upto 10Mtr from tapping point to out let via switch | Point | 570.0 | 570.0 | 6.0 | False | None | None | False | None | False | 3420.0 | 0 | 2995111 | 99592 | None | ELE P-1 It.No.3.4.3 Pg.08 | Supplying and flush mounting powder coated/Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 4-5 Way | Each | 177.0 | 177.0 | 8.0 | False | None | None | False | None | False | 1416.0 | 0 | 2994954 | 99592 | None | V-1 1.8 7 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 497.7 | 497.7 | 62.46 | False | None | None | False | None | False | 31086.342 | 0 | 2995059 | 99592 | None | V-1 1.9 Pg. 34 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 279.3 | 279.3 | 39.91 | False | None | None | False | None | False | 11146.863 | 0 | 2995183 | 99592 | None | V-2 13.31.1 122 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 15 mm nominal dia Pipes | m | 191.1 | 191.1 | 30.0 | False | None | None | False | None | False | 5733.0 | 0 | 2995153 | 99592 | None | V-2 5.4 9 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 2.62 | False | None | None | False | None | False | 17576.139 | 0 | 2995100 | 99592 | None | V-5 10.1.7 Pg. 113 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and cmmissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 110mm dia., 6 kg/sqcm & class 3 | m | 431.55 | 431.55 | 20.0 | False | None | None | False | None | False | 8631.0 | 0 | 2995221 | 99592 | None | Vol-3, 16.27 Pg-148 | Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M20 (Grade), coarse and fine aggregates conforming to IS:383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, , primer, sealant , curing of concrete slabs for 14-days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work. | Cum | 6692.7 | 6692.7 | 392.5 | False | None | None | False | None | False | 2626884.75 | 0 | 2994990 | 99592 | None | Vol-6.Chapter-1.It No - 1.5.3.Page No.3of105 | Supplying and fixing PVC/metal conduit Deep junction box - 32mm deep junction box | Each | 61.0 | 61.0 | 2.0 | False | None | None | False | None | False | 122.0 | 0 | 2995196 | 99592 | None | ELE P-1 It.No.2.3.2, Pg.05 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper conductor single core wire in open or concealed system of wiring as per IS-694:1990 & confirming to GTP of GROUP -B. - 1.5 sqmm | Mtr | 26.0 | 26.0 | 70.0 | False | None | None | False | None | False | 1820.0 | 0 | 2995112 | 99592 | None | ELE P-1 It.No.3.4.4 Pg.08 | Supplying and flush mounting powder coated/Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 6 Way | Each | 220.0 | 220.0 | 4.0 | False | None | None | False | None | False | 880.0 | 0 | 2995154 | 99592 | None | V-1 1.11 7 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 454.65 | 454.65 | 6.0 | False | None | None | False | None | False | 2727.9 | 0 | 2994969 | 99592 | None | V-1 2.5.1 17 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregatesas per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6961.5 | 6961.5 | 0.38 | False | None | None | False | None | False | 2645.37 | 0 | 2995060 | 99592 | None | V-1 I no 2.2.3 P no 15 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregatesas per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6652.8 | 6652.8 | 3.89 | False | None | None | False | None | False | 25879.392 | 0 | 2995184 | 99592 | None | V-2 13.58 127 | Providing and fixing PVC (S.W.R) Gully Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete | Each | 363.3 | 363.3 | 2.0 | False | None | None | False | None | False | 726.6 | 0 | 2995101 | 99592 | None | V-2 14.10.2.2 Pg. 134 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board 610x460 mm bowl depth 200 mm DSR 2021-22 V-2 I.No 14.10.2.2 Pg.No 126 | m | 2982.0 | 2982.0 | 1.0 | False | None | None | False | None | False | 2982.0 | 0 | 2994955 | 99592 | None | V-2 8.19.1 44 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge. | Sqm | 267.75 | 267.75 | 19.35 | False | None | None | False | None | False | 5180.9625 | 0 | 2994991 | 99592 | None | Vol-6.Chapter-2.It No -2.1.2.Page No.5 of 105 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A - Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch | Point | 394.0 | 394.0 | 4.0 | False | None | None | False | None | False | 1576.0 | 0 | 2994970 | 99592 | None | Corrigendum-3 Sl.No 08 Pno 02 | Add Formwork, Centering & Scaffolding charges for Columns 70% vide Corrigendum - 03 Appendix-I Sl.no 8 P.no 2 | Cum | 4873.05 | 4873.05 | 0.38 | False | None | None | False | None | False | 1851.759 | 0 | 2995197 | 99592 | None | ELE P-1 It.No.2.3.3, Pg.05 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper conductor single core wire in open or concealed system of wiring as per IS-694:1990 & confirming to GTP of GROUP -B. - 2.5 sqmm | Mtr | 42.0 | 42.0 | 70.0 | False | None | None | False | None | False | 2940.0 | 0 | 2995113 | 99592 | None | ELE P-1 It.No.3.4.5 Pg.08 | Supplying and flush mounting powder coated/Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 8 Way | Each | 261.0 | 261.0 | 2.0 | False | None | None | False | None | False | 522.0 | 0 | 2995061 | 99592 | None | V-1 Addendum I Sl.no 1.b P.no 111 | Additional Form work for Shuttering, Centering work for Footing work 3% | Cum | 199.58 | 199.58 | 3.89 | False | None | None | False | None | False | 776.3662 | 0 | 2995155 | 99592 | None | V-1 I no 2.5.2 P no 16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 7185.15 | 7185.15 | 0.9 | False | None | None | False | None | False | 6466.635 | 0 | 2995102 | 99592 | None | V-2 13.14 Pg. 119 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 g. | Nos | 888.3 | 888.3 | 2.0 | False | None | None | False | None | False | 1776.6 | 0 | 2995185 | 99592 | None | V-2 13.59 127 | Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete | Each | 231.0 | 231.0 | 2.0 | False | None | None | False | None | False | 462.0 | 0 | 2994956 | 99592 | None | V-2 9.24 63 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. | Sqm | 2994.6 | 2994.6 | 169.63 | False | None | None | False | None | False | 507973.998 | 0 | 2994992 | 99592 | None | Vol-6.Chapter-2.It No -2.1.3.Page No.5 of 105 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A - Long point above 6Mtr upto 10Mtr from tapping point to out let via switch | Point | 570.0 | 570.0 | 6.0 | False | None | None | False | None | False | 3420.0 | 0 | 2995198 | 99592 | None | ELE P-1 It.No.1.6.3,Pg.03 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete. -10"x7"x3" (254x178x76mm), | Each | 112.0 | 112.0 | 5.0 | False | None | None | False | None | False | 560.0 | 0 | 2995114 | 99592 | None | ELE P-1 It.No.3.5.1 Pg.08 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 1 to 2 module | Each | 137.0 | 137.0 | 1.0 | False | None | None | False | None | False | 137.0 | 0 | 2994971 | 99592 | None | V-1 2.5.1 17 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregatesas per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6961.5 | 6961.5 | 2.07 | False | None | None | False | None | False | 14410.305 | 0 | 2995156 | 99592 | None | V-1 Addendum I Sl.no 2 P.no 111 | Additional Form work for Shuttering, Centering work for Plinth beam work 50% | Cum | 3592.58 | 3592.58 | 0.9 | False | None | None | False | None | False | 3233.322 | 0 | 2995062 | 99592 | None | V-1 I no 2.5.2 P no 16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 7185.15 | 7185.15 | 1.06 | False | None | None | False | None | False | 7616.259 | 0 | 2994957 | 99592 | None | V-2 12.12 99 | Providing Mathi/Nandi wood frames of doors, windows, clerestorywindows, ventilators and other frames, wrought, framed or assembledincluding making plaster groves (excluding cost of cement concrete and sideclamps ), but including cost of materials, labour, usage charges completeas per specifications | Cum | 130412.1 | 130412.1 | 0.1 | False | None | None | False | None | False | 13041.21 | 0 | 2995103 | 99592 | None | V-2 14.7.1 Pg. 132 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps | Each | 3236.1 | 3236.1 | 1.0 | False | None | None | False | None | False | 3236.1 | 0 | 2995186 | 99592 | None | V-5 10.2.4 114 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: 160MM DIA | m | 604.8 | 604.8 | 100.0 | False | None | None | False | None | False | 60480.0 | 0 | 2994993 | 99592 | None | Vol-6.Chapter-2.It No -2.1.4.Page No.5 of 105 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A - Two outlet in a row, above 3Mtr upto 6Mtr from tapping point to out let via switches | Point | 708.0 | 708.0 | 4.0 | False | None | None | False | None | False | 2832.0 | 0 | 2994972 | 99592 | None | Corrigendum-3 Sl.No 1a Pno 2. | Add Formwork, Centering & Scaffolding charges forPlinth Beam of Buildings 50% vide Corrigendum - 03 Appendix-I Sl.no 1a P.no 2 | Cum | 3480.75 | 3480.75 | 2.07 | False | None | None | False | None | False | 7205.1525 | 0 | 2995199 | 99592 | None | ELE P-1 ,It No.3.8,Pg.09 | Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc., and fixing on existing wooden or metal box using N.F. screws. | Sq CM | 0.41 | 0.41 | 1000.0 | False | None | None | False | None | False | 410.0 | 0 | 2995115 | 99592 | None | ELE P-1 It.No.3.5.3 Pg.08 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 4 module | Each | 175.0 | 175.0 | 4.0 | False | None | None | False | None | False | 700.0 | 0 | 2995063 | 99592 | None | V-1 Addendum I Sl.no 9 P.no 111 | Additional Form work for Shuttering, Centering work for Column work 70% | Cum | 5029.61 | 5029.61 | 1.06 | False | None | None | False | None | False | 5331.3866 | 0 | 2995157 | 99592 | None | V-1 I no 2.5.2 P no 16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 7185.15 | 7185.15 | 0.45 | False | None | None | False | None | False | 3233.3175 | 0 | 2994958 | 99592 | None | V-2 12.15 100 | Providing and fixing in position fully panelled Mathi/Nandi wood shuttersfor doors with stiles and rails of 40mm. thick with bottom and lock rails180mm wide top rail and stiles 100mm wide as per drawing and panels of25mm thick including cost of materials, labour, usage charges completeas per specifications. (excluding cost of fixtures | Sqm | 7241.85 | 7241.85 | 5.04 | False | None | None | False | None | False | 36498.924 | 0 | 2995187 | 99592 | None | V-2 13.14 119 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 g. | Nos | 888.3 | 888.3 | 4.0 | False | None | None | False | None | False | 3553.2 | 0 | 2995104 | 99592 | None | V-2 14.32.4 Pg. 136 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 1500x450 mm DSR 2021- 22 V-2 I.No 14.32.4 Pg 129 | Nos | 1812.3 | 1812.3 | 1.0 | False | None | None | False | None | False | 1812.3 | 0 | 2994994 | 99592 | None | Vol-6.Chapter-2.It No -2.3.2.Page No.5 of 105 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP -A. - 1.5sqmm. | Mtr | 26.0 | 26.0 | 150.0 | False | None | None | False | None | False | 3900.0 | 0 | 2995200 | 99592 | None | ELE P-1 It.No.3.14.1, Pg.10 | Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board. GROUP A - 6Amps SP Switch | Each | 55.0 | 55.0 | 7.0 | False | None | None | False | None | False | 385.0 | 0 | 2995116 | 99592 | None | ELE P-1 It.No.3.5.4 Pg.08 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 6 module | Each | 234.0 | 234.0 | 2.0 | False | None | None | False | None | False | 468.0 | 0 | 2994973 | 99592 | None | V-1 2.5.1 17 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregatesas per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6961.5 | 6961.5 | 1.27 | False | None | None | False | None | False | 8841.105 | 0 | 2995158 | 99592 | None | V-1 Addendum I Sl.no 14 P.no 111 | Additional Form work for Shuttering, Centering work for Lintel & Roof beam work 60% | Cum | 4311.09 | 4311.09 | 0.45 | False | None | None | False | None | False | 1939.9905 | 0 | 2995064 | 99592 | None | V-1 I no 2.5.2 P no 16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 7185.15 | 7185.15 | 1.92 | False | None | None | False | None | False | 13795.488 | 0 | 2994959 | 99592 | None | V-2 12.51 104 | Fixing of door frame in an existing opening including embedding frame infloor and walls after cutting masonry for holdfasts for embedding holdfastin cement concrete 1:3:6 of 20mm and down size granite metal paintingtwo coats of coal tar to sides of frame, making good the damages to wallsand floor as required and disposal of the debris with lead upto 50 m.including cost of materials, labour charges, complete as per specifications. | Sqm | 1066.8 | 1066.8 | 2.0 | False | None | None | False | None | False | 2133.6 | 0 | 2995105 | 99592 | None | V-2 13.39 Pg. 123 | Providing stoneware gully trap SP-1 Complete with CI grating brick masonry chamber 150 x 100 mm size P type with non modular common burnt clay bricks of designation 3.5 & with water tight C.I Cover with frame of 300 x 300mm size Inside the weight of cover to be not less than 4.50 kg and frame to be not less than 2.7 kg per standard design. DSR V-2 I.No 13.39 | Nos | 2710.05 | 2710.05 | 2.0 | False | None | None | False | None | False | 5420.1 | 0 | 2995188 | 99592 | None | V-2 14.7.1 132 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps | Each | 3236.1 | 3236.1 | 2.0 | False | None | None | False | None | False | 6472.2 | 0 | 2994995 | 99592 | None | Vol-6.Chapter-2.It No -2.3.3.Page No.5 of 105 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP -A. - 2.5sqmm. | Mtr | 42.0 | 42.0 | 200.0 | False | None | None | False | None | False | 8400.0 | 0 | 2994974 | 99592 | None | Corrigendum-3 Sl.No 08 Pno 02 | Add Formwork, Centering & Scaffolding charges for Columns 70% vide Corrigendum - 03 Appendix-I Sl.no 8 P.no 2 | Cum | 4873.05 | 4873.05 | 1.27 | False | None | None | False | None | False | 6188.7735 | 0 | 2995201 | 99592 | None | ELE P-1 ,It. No.3.14.7, Pg.10 | Supplying and fixing PBBC/Bakelite straight or slant batten holder and wiring with 60w/230 Vts lamps | Each | 74.0 | 74.0 | 6.0 | False | None | None | False | None | False | 444.0 | 0 | 2995117 | 99592 | None | ELE P-1 It.No.3.5.5 Pg.08 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 8 module | Each | 284.0 | 284.0 | 2.0 | False | None | None | False | None | False | 568.0 | 0 | 2995065 | 99592 | None | V-1 Addendum I Sl.no 2 P.no 111 | Additional Form work for Shuttering, Centering work for Plinth beam work 50% | Cum | 3592.58 | 3592.58 | 1.92 | False | None | None | False | None | False | 6897.7536 | 0 | 2995159 | 99592 | None | V-1 I no 2.11a P no 18 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Buildings | t | 93929.85 | 93929.85 | 0.11 | False | None | None | False | None | False | 10332.2835 | 0 | 2994960 | 99592 | None | V-2 11.28 83 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 593.25 | 593.25 | 548.64 | False | None | None | False | None | False | 325480.68 | 0 | 2995106 | 99592 | None | V-2 13.22.1.2 Pg. 120 | Providing and fixing PTMT grating of approved quality and colour. 125 mm nominal dia DSR 2021-22 I.No 13.22.1.2 Pg. 118 | Nos | 46.2 | 46.2 | 2.0 | False | None | None | False | None | False | 92.4 | 0 | 2995189 | 99592 | None | V-5 16.9 191 | Constructing brick masonry chamber of internal dimension 600x600 mm and depth of 600 mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150 mm thick with 1:3:6, lastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75 mm thick for fixing CI cover & frame etc. excluding the cost of CI frame and cover. | Each | 5726.7 | 5726.7 | 4.0 | False | None | None | False | None | False | 22906.8 | 0 | 2994996 | 99592 | None | Vol-6.Chapter-2.It No -2.3.4.Page No.5 of 105 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP -A. - 4.0sqmm. | Mtr | 63.0 | 63.0 | 150.0 | False | None | None | False | None | False | 9450.0 | 0 | 2995202 | 99592 | None | ELE P-1 , It.No.11.3.2, Pg. 34 | Supplying patti type fluorescent tube light fitting of 4' -suitable for 28 watts fluorescent tube fitting, made out of M.S. Sheet and stove enameled with HF Electronic Ballast , locking type brass contact holders mounted on double fold type sheet base fully wired for use on 230 Vts AC . Supply including T5 lamp | Each | 740.0 | 740.0 | 3.0 | False | None | None | False | None | False | 2220.0 | 0 | 2995118 | 99592 | None | ELE P-1 It.No.3.6.1 Pg.09 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate 6 amps one way switch | Each | 102.0 | 102.0 | 2.0 | False | None | None | False | None | False | 204.0 | 0 | 2994975 | 99592 | None | V-1 2.11A 18 | Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | t | 93929.85 | 93929.85 | 0.3 | False | None | None | False | None | False | 28178.955 | 0 | 2995066 | 99592 | None | V-1 I no 2.5.2 P no 16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 7185.15 | 7185.15 | 2.24 | False | None | None | False | None | False | 16094.736 | 0 | 2994961 | 99592 | None | V-2 11.25.2 84 | Providing and fixing Steel work welded in built up sections/ framedwork, including cutting, hoisting, fixing in position and applying a primingcoat of approved steel primer using structural steel etc. as required. Ingratings, frames, guard bar, ladder, railings, brackets, gates and similarworks including cost of materials, labour, usage charges of machinerycomplete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 142.8 | 142.8 | 183.75 | False | None | None | False | None | False | 26239.5 | 0 | 2995160 | 99592 | None | V-2 I no 6.8 P no 14 | Providing Brick work with common burnt clay Non Modular bricks ofclass designation 3.5 in superstructure above plinth level in all shapes andsizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost ofall materials, labour, scaffolding and usage charges of machinery & otherincidental charges complete as per the direction of engineer incharge ofwork. | Cum | 8367.45 | 8367.45 | 8.23 | False | None | None | False | None | False | 68864.1135 | 0 | 2995190 | 99592 | None | V-5 16.23.2 196 | Providing and fixing SFRC frame and cover conforming to IS 12592 (part-I)-1988 and IS 12592 (part-II)- 1991 with latest amendment, including cutting slabs to the required size for the opening and fixing the cover in C.C. 1:2:4 and C.M. 1:3 plastering 20 mm thick to all exposed faces, curing for 10 days with all lead and lift with appurtenances. complete | Set | 2692.2 | 2692.2 | 4.0 | False | None | None | False | None | False | 10768.8 | 0 | 2994997 | 99592 | None | Vol-6.Chapter-3.It No - 3.4.4.Page No.8 of 105 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 6Way | Each | 220.0 | 220.0 | 4.0 | False | None | None | False | None | False | 880.0 | 0 | 2995203 | 99592 | None | ELE P-1 , It.No.13.7.1,Pg. 56 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. - On wall / ceiling / Rafter / Girders | Nos | 122.0 | 122.0 | 3.0 | False | None | None | False | None | False | 366.0 | 0 | 2995119 | 99592 | None | ELE P-1 It.No.3.6.2 Pg.09 | 6 amps Two way switch | Each | 166.0 | 166.0 | 2.0 | False | None | None | False | None | False | 332.0 | 0 | 2995067 | 99592 | None | V-1 Addendum I Sl.no 9 P.no 111 | Additional Form work for Shuttering, Centering work for Column work 70% | Cum | 5029.61 | 5029.61 | 2.24 | False | None | None | False | None | False | 11266.3264 | 0 | 2994976 | 99592 | None | V-2 6.32 14 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications | Sqm | 1375.5 | 1375.5 | 112.64 | False | None | None | False | None | False | 154936.32 | 0 | 2994962 | 99592 | None | V-2 8.33.3 46 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 145.95 | 145.95 | 122.56 | False | None | None | False | None | False | 17887.632 | 0 | 2995161 | 99592 | None | V-2 I no 8.1.2 P no 41 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement:6 fine sand) including rounding off corners wherever required smoothrendering, providing and removing scaffolding, including cost of materials,labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 253.05 | 253.05 | 43.68 | False | None | None | False | None | False | 11053.224 | 0 | 2994998 | 99592 | None | Vol-6.Chapter-3.It No - 3.4.5.Page No.8 of 105 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 8Way | Each | 261.0 | 261.0 | 6.0 | False | None | None | False | None | False | 1566.0 | 0 | 2995204 | 99592 | None | ELE P-1 It.No.11.8.2 , Pg.36 | Supply of Horizontal type Street light fluorescent fitting suitable for single/twin lamp of 24W/28W FTL T5 lamp. Housing shall be with pressure die cast aluminum with UV Protected clear acrylic diffuser with thermoformed & CRCA gear tray, push fit poly carbonate lamp holder, low loss high frequency electronic ballast with IP 54 protection. - 2x4'-28Watts | Each | 3651.0 | 3651.0 | 1.0 | False | None | None | False | None | False | 3651.0 | 0 | 2995120 | 99592 | None | ELE P-1 It.No.3.6.3Pg.09 | 6 Amps 3 way sockets | Each | 171.0 | 171.0 | 2.0 | False | None | None | False | None | False | 342.0 | 0 | 2995068 | 99592 | None | V-1 I no 2.5.2 P no 16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 7185.15 | 7185.15 | 3.04 | False | None | None | False | None | False | 21842.856 | 0 | 2994977 | 99592 | None | V-2 8.1.1 41 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 267.75 | 267.75 | 266.9 | False | None | None | False | None | False | 71462.475 | 0 | 2994963 | 99592 | None | V-2 8.28 45 | Finishing walls with water proofing cement paint of required shade :Newwork (Two coats applied @ 4.84 kg/10 m²) to give an even shade afterthoroughly brooming the surface to remove all dirt, dust, mortar dropsand foreign matter including preparing the surface even and sand papersmooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge. | Sqm | 93.45 | 93.45 | 18.0 | False | None | None | False | None | False | 1682.1 | 0 | 2995162 | 99592 | None | V-2 I no 8.8 P no 42 | Providing 18 mm cement plaster in two coats under layer 12 mm thickcement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finishedwith a top layer 6 mm thick cement plaster with cement mortar 1:6 (1cement : 6 fine sand) to brick masonry including rounding off cornerswherever required smooth rendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specificationsand as per directions of Engineer-in-charge. | Sqm | 389.55 | 389.55 | 34.14 | False | None | None | False | None | False | 13299.237 | 0 | 2994999 | 99592 | None | Vol-6.Chapter-3.It No - 3.4.6.Page No.8 of 105 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone- 10-12Way | Each | 319.0 | 319.0 | 4.0 | False | None | None | False | None | False | 1276.0 | 0 | 2995205 | 99592 | None | ELE P-1 , It.No.13.7.2, Pg.56 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clampsFixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps., Using necessary length of G.I. chain. | Each | 263.0 | 263.0 | 1.0 | False | None | None | False | None | False | 263.0 | 0 | 2995121 | 99592 | None | ELE P-1 It.No.3.6.4 Pg.09 | stepped fan Regulator's | Each | 357.0 | 357.0 | 2.0 | False | None | None | False | None | False | 714.0 | 0 | 2995069 | 99592 | None | V-1 Addendum I Sl.no 14 P.no 111 | Additional Form work for Shuttering, Centering work for Lintel & Roof beam work 60% | Cum | 4311.09 | 4311.09 | 3.04 | False | None | None | False | None | False | 13105.7136 | 0 | 2994978 | 99592 | None | V-2 8.30 46 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 182.7 | 182.7 | 266.9 | False | None | None | False | None | False | 48762.63 | 0 | 2995163 | 99592 | None | V-2 I no 8.19.1 P no 44 | Providing Flush/ Ruled pointing: Pointing on stone work with cementmortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining,including cost of materials, labour, curing as per specifications and asper directions of Engineer-in-charge | Sqm | 267.75 | 267.75 | 6.22 | False | None | None | False | None | False | 1665.405 | 0 | 2995000 | 99592 | None | Vol-6.Chapter-3.It No - 3.4.7.Page No.8 of 105 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone wall - 16-18Way | Each | 363.0 | 363.0 | 2.0 | False | None | None | False | None | False | 726.0 | 0 | 2995206 | 99592 | None | ELE P-1 , It.No.5.44.1,Pg.21 | Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. - 300mmx300mmx214mm. | Each | 4512.0 | 4512.0 | 1.0 | False | None | None | False | None | False | 4512.0 | 0 | 2995122 | 99592 | None | ELE P-1 It.No.3.6.7 Pg.09 | 16A one way switch | Each | 180.0 | 180.0 | 1.0 | False | None | None | False | None | False | 180.0 | 0 | 2995070 | 99592 | None | V-1 I no 2.5.2 P no 16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 7185.15 | 7185.15 | 4.79 | False | None | None | False | None | False | 34416.8685 | 0 | 2995164 | 99592 | None | V-2 8.22 44 | Providing lime wash on walls with one coat with lime of approved quality to give an even shade, including cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 10.5 | 10.5 | 43.68 | False | None | None | False | None | False | 458.64 | 0 | 2994979 | 99592 | None | V-2 8.29 45 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 297.15 | 297.15 | 1142.0 | False | None | None | False | None | False | 339345.3 | 0 | 2995001 | 99592 | None | Vol-6.Chapter-3.It No - 3.5.4.Page No.8 of 105 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 6 Module | Each | 234.0 | 234.0 | 4.0 | False | None | None | False | None | False | 936.0 | 0 | 2995207 | 99592 | None | ELE P-1 , It.No.5.18.1, Pg.17 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. - 6-32Amps SP | Each | 415.0 | 415.0 | 1.0 | False | None | None | False | None | False | 415.0 | 0 | 2995123 | 99592 | None | ELE P-1 It.No.3.6.10 Pg.09 | 6/16 Amps universal sockets | Each | 236.0 | 236.0 | 1.0 | False | None | None | False | None | False | 236.0 | 0 | 2995071 | 99592 | None | V-1 Addendum I Sl.no 15 P.no 111 | Additional Form work for Shuttering, Centering work for Roof Slab work 50% | Cum | 3592.58 | 3592.58 | 4.79 | False | None | None | False | None | False | 17208.4582 | 0 | 2995165 | 99592 | None | V-2 9.11 60 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. | Sqm | 933.45 | 933.45 | 10.46 | False | None | None | False | None | False | 9763.887 | 0 | 2995002 | 99592 | None | Vol-6.Chapter-3.It No - 3.5.5.Page No.8 of 105 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 8Module | Each | 284.0 | 284.0 | 6.0 | False | None | None | False | None | False | 1704.0 | 0 | 2995208 | 99592 | None | ELE P-1 ,It.No.5.18.5, Pg.17 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. - 50-63Amps DP | Each | 1102.0 | 1102.0 | 1.0 | False | None | None | False | None | False | 1102.0 | 0 | 2995124 | 99592 | None | ELE P-1 It.No.3.6.9 Pg.09 | 32 A DP switch | Each | 326.0 | 326.0 | 1.0 | False | None | None | False | None | False | 326.0 | 0 | 2995072 | 99592 | None | V-1 I no 2.5.2 P no 16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 7185.15 | 7185.15 | 0.34 | False | None | None | False | None | False | 2442.951 | 0 | 2995166 | 99592 | None | V-2 10.14 71 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. | Sqm | 1161.3 | 1161.3 | 33.6 | False | None | None | False | None | False | 39019.68 | 0 | 2995003 | 99592 | None | Vol-6.Chapter-3.It No - 3.5.6.Page No.8 of 105 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 10-12Module | Each | 344.0 | 344.0 | 4.0 | False | None | None | False | None | False | 1376.0 | 0 | 2995209 | 99592 | None | ELE P-1 ,It.No.5.20.4,Pg.18 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board. - 32-40A 2 pole | Each | 4559.0 | 4559.0 | 1.0 | False | None | None | False | None | False | 4559.0 | 0 | 2995125 | 99592 | None | ELE P-1 It.No.1.13 Pg.03 | Supply and fixing one metal Fan box with round hook | Each | 117.0 | 117.0 | 1.0 | False | None | None | False | None | False | 117.0 | 0 | 2995073 | 99592 | None | V-1 Addendum I Sl.no 19 P.no 111 | Additional Form work for Shuttering, Centering work for Chejja 45% | Cum | 3233.32 | 3233.32 | 0.34 | False | None | None | False | None | False | 1099.3288 | 0 | 2995167 | 99592 | None | V-2 9.23 63 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent.e. | Sqm | 2589.3 | 2589.3 | 3.0 | False | None | None | False | None | False | 7767.9 | 0 | 2995004 | 99592 | None | Vol-6.Chapter-3.It No - 3.5.7.Page No.8 of 105 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 16 Module | Each | 397.0 | 397.0 | 2.0 | False | None | None | False | None | False | 794.0 | 0 | 2995210 | 99592 | None | ELE P-1 ,It.No.5.30, Pg.19 | Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter | Each | 1380.0 | 1380.0 | 1.0 | False | None | None | False | None | False | 1380.0 | 0 | 2995126 | 99592 | None | ELE P-1 It.No 1.2.1 Pg.02 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures seen with fish wires where ever necessary 20mm dia | m | 66.0 | 66.0 | 15.0 | False | None | None | False | None | False | 990.0 | 0 | 2995074 | 99592 | None | V-1 I no 2.11a P no 18 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Buildings | t | 93929.85 | 93929.85 | 1.46 | False | None | None | False | None | False | 137137.581 | 0 | 2995168 | 99592 | None | V-2 12.54 104 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm ong brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. | m | 333.9 | 333.9 | 12.0 | False | None | None | False | None | False | 4006.8 | 0 | 2995005 | 99592 | None | Vol-6.Chapter-3.It No - 3.6.1.Page No.9 of 105 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps one way switch. | Each | 102.0 | 102.0 | 10.0 | False | None | None | False | None | False | 1020.0 | 0 | 2995127 | 99592 | None | ELE P-1 It.No 1.2.2 Pg.02 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures seen with fish wires where ever necessary 25mm dia | m | 78.0 | 78.0 | 15.0 | False | None | None | False | None | False | 1170.0 | 0 | 2995211 | 99592 | None | ESCOM P-3 212 It.No.32.02, Pg.13 | Supplying of 1.1 KV LT UG cable having aluminum conductor PVC insulated, extruded inner sheathed, galvanized, steel strip (except 2CX10Sq.mm wire armoured) confirming to IS-3975:1990 (No. of Strip indicated in GTP) & extruded PVC outer sheathed armoured cable with specified IS-1554 Part-1:1988 & confirming to GTP of GROUP-A. - 2 core 10 sqmm | Kms | 79232.0 | 79232.0 | 0.07 | False | None | None | False | None | False | 5546.24 | 0 | 2995169 | 99592 | None | V-2 12.55.1 106 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. -do- with both side prelam | Sqm | 2484.3 | 2484.3 | 3.78 | False | None | None | False | None | False | 9390.654 | 0 | 2995075 | 99592 | None | V-2 I no 6.8 P no 14 | Providing Brick work with common burnt clay Non Modular bricks ofclass designation 3.5 in superstructure above plinth level in all shapes andsizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost ofall materials, labour, scaffolding and usage charges of machinery & otherincidental charges complete as per the direction of engineer incharge ofwork. | Cum | 8367.45 | 8367.45 | 16.22 | False | None | None | False | None | False | 135720.039 | 0 | 2995006 | 99592 | None | Vol-6.Chapter-3.It No - 3.6.4.Page No.9 of 105 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 Stepped fan regulator. | Each | 357.0 | 357.0 | 4.0 | False | None | None | False | None | False | 1428.0 | 0 | 2995128 | 99592 | None | ELE P-1 It.No 1.3.1 Pg.02 | Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20mm dia | m | 68.0 | 68.0 | 20.0 | False | None | None | False | None | False | 1360.0 | 0 | 2995212 | 99592 | None | ESCOM P-3 212 It.No.32.05, Pg.13 | Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required.In existing trench/duct. - 6 sqmm to 16 sqmm | Kms | 141842.0 | 141842.0 | 0.07 | False | None | None | False | None | False | 9928.94 | 0 | 2995170 | 99592 | None | V-2 11.11.1 79 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and 12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). | Kg | 155.4 | 155.4 | 11.34 | False | None | None | False | None | False | 1762.236 | 0 | 2995076 | 99592 | None | V-2 I no 8.1.2 P no 41 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement:6 fine sand) including rounding off corners wherever required smoothrendering, providing and removing scaffolding, including cost of materials,labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 253.05 | 253.05 | 126.39 | False | None | None | False | None | False | 31982.9895 | 0 | 2995007 | 99592 | None | Vol-6.Chap-3.It No 3.6.7.Page No.9 of 105 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 16Amps one way switch. | Each | 180.0 | 180.0 | 10.0 | False | None | None | False | None | False | 1800.0 | 0 | 2995129 | 99592 | None | ELE P-1 It.No 1.3.2 Pg.02 | Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25mm dia | m | 79.0 | 79.0 | 20.0 | False | None | None | False | None | False | 1580.0 | 0 | 2995171 | 99592 | None | V-2 8.27 45 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 55.65 | 55.65 | 18.08 | False | None | None | False | None | False | 1006.152 | 0 | 2995077 | 99592 | None | V-2 I no 8.8 P no 42 | Providing 18 mm cement plaster in two coats under layer 12 mm thickcement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finishedwith a top layer 6 mm thick cement plaster with cement mortar 1:6 (1cement : 6 fine sand) to brick masonry including rounding off cornerswherever required smooth rendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specificationsand as per directions of Engineer-in-charge. | Sqm | 389.55 | 389.55 | 85.32 | False | None | None | False | None | False | 33236.406 | 0 | 2995213 | 99592 | None | Vol-1 I.no 1.6.1 Pg.no 06 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m | m | 484.0 | 484.0 | 20.0 | False | None | None | False | None | False | 9680.0 | 0 | 2995008 | 99592 | None | Vol-6.Chapt-3.It No 3.6.3.Page No.9 of 105 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps 3way socket. | Each | 171.0 | 171.0 | 10.0 | False | None | None | False | None | False | 1710.0 | 0 | 2995130 | 99592 | None | ELE P-1 It.No 2.3.2 Pg.05 | WIRING FOR Lighting/Power Circuits using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A. 1.5 sqmm | m | 26.0 | 26.0 | 30.0 | False | None | None | False | None | False | 780.0 | 0 | 2995172 | 99592 | None | V-2 8.28 45 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 93.45 | 93.45 | 18.08 | False | None | None | False | None | False | 1689.576 | 0 | 2995078 | 99592 | None | V-2 I no 8.19.1 P no 44 | Providing Flush/ Ruled pointing: Pointing on stone work with cementmortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining,including cost of materials, labour, curing as per specifications and asper directions of Engineer-in-charge | Sqm | 267.75 | 267.75 | 15.65 | False | None | None | False | None | False | 4190.2875 | 0 | 2995214 | 99592 | None | Vol-1 I.no 1.10 Pg.no 07 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications | Cum | 160.0 | 160.0 | 12.0 | False | None | None | False | None | False | 1920.0 | 0 | 2995009 | 99592 | None | Vol-6.Chapt-3.It No3.6.10.Page No.9 of 105 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6/16Amps universal socket. | Each | 236.0 | 236.0 | 6.0 | False | None | None | False | None | False | 1416.0 | 0 | 2995131 | 99592 | None | ELE P-1 It.No 2.3.3 Pg.05 | WIRING FOR Lighting/Power Circuits using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A. 2.5 sqmm | m | 42.0 | 42.0 | 30.0 | False | None | None | False | None | False | 1260.0 | 0 | 2995215 | 99592 | None | ELEBESCOM P-3 51.04 23 | Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified | Nos | 2172.0 | 2172.0 | 1.0 | False | None | None | False | None | False | 2172.0 | 0 | 2995173 | 99592 | None | V-2 8.30 46 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 182.7 | 182.7 | 40.36 | False | None | None | False | None | False | 7373.772 | 0 | 2995079 | 99592 | None | V-2 I no 8.51 P no 50 | Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plasteredwall surface to prepare the surface even and smooth complete as perspecifications and as per directions of Engineer in charge. | Sqm | 105.0 | 105.0 | 126.39 | False | None | None | False | None | False | 13270.95 | 0 | 2995010 | 99592 | None | Vol-6.Chapt-5.It No 5.7.3.Pg No.14 of 105 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 63Amps | Each | 401.0 | 401.0 | 2.0 | False | None | None | False | None | False | 802.0 | 0 | 2995132 | 99592 | None | ELE P-1 It.No 2.3.4 Pg.05 | WIRING FOR Lighting/Power Circuits using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A. 4.0 sqmm | m | 63.0 | 63.0 | 30.0 | False | None | None | False | None | False | 1890.0 | 0 | 2995216 | 99592 | None | ELEBESCOM P-3 51.05 23 | Bentonite clay slurry for earthing in 50 Kg Bag | Nos | 368.0 | 368.0 | 1.0 | False | None | None | False | None | False | 368.0 | 0 | 2995174 | 99592 | None | V-2 11.34B 86 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. | Kg | 192.15 | 192.15 | 11.34 | False | None | None | False | None | False | 2178.981 | 0 | 2995080 | 99592 | None | V-2 8.27 Pg. 45 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 55.65 | 55.65 | 154.39 | False | None | None | False | None | False | 8591.8035 | 0 | 2995011 | 99592 | None | Vol-6.Chapt-5.It No 5.8.1.Pg No.15 of 105 | Supplying of Switch disconnector fuse unit (TPN) HRC type (but without HRC fuses). With AC-23A duty and as per IS-13947. 63Amps | Each | 2312.0 | 2312.0 | 1.0 | False | None | None | False | None | False | 2312.0 | 0 | 2995133 | 99592 | None | ELE P-1 It.No 5.19.8 Pg.18 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting. Made out of 14SWG MS enclouser. 8way SP & N | Each | 1854.0 | 1854.0 | 1.0 | False | None | None | False | None | False | 1854.0 | 0 | 2995175 | 99592 | None | V-2 12.61 105 | Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete. | Nos | 1039.5 | 1039.5 | 2.0 | False | None | None | False | None | False | 2079.0 | 0 | 2995081 | 99592 | None | V-2 8.39 Pg. 48 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 133.35 | 133.35 | 154.39 | False | None | None | False | None | False | 20587.9065 | 0 | 2995012 | 99592 | None | Vol-6.Chapter-5.It No - 5.15.1.Page No.17 of 105 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics) THREE POLE 100Amps 25kA. | Each | 6086.0 | 6086.0 | 1.0 | False | None | None | False | None | False | 6086.0 | 0 | 2995134 | 99592 | None | ELE P-1 It.No 5.18.1 Pg.17 | Supplying and fixing miniature circuit breaker, on the existing MCB distribution board using necessary fixing materials and C type curve,indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K & complete wiring as required conforming to IEC 60898. 6-32 Amps Sp | Each | 415.0 | 415.0 | 2.0 | False | None | None | False | None | False | 830.0 | 0 | 2995176 | 99592 | None | V-2 12.74.1 107 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm | Nos | 107.1 | 107.1 | 6.0 | False | None | None | False | None | False | 642.6 | 0 | 2995082 | 99592 | None | V-2 8.30 Pg. 46 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 182.7 | 182.7 | 100.97 | False | None | None | False | None | False | 18447.219 | 0 | 2995013 | 99592 | None | Vol-6.Chapter-5.It No - 5.18.3.Page No.17of105 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63Amps SP | Each | 811.0 | 811.0 | 4.0 | False | None | None | False | None | False | 3244.0 | 0 | 2995135 | 99592 | None | ELE P-1 It.No 5.18.4 Pg.17 | Supplying and fixing miniature circuit breaker, on the existing MCB distribution board using necessary fixing materials and C type curve,indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K & complete wiring as required conforming to IEC 60898. 6-32 Amps DP | Each | 739.0 | 739.0 | 1.0 | False | None | None | False | None | False | 739.0 | 0 | 2995177 | 99592 | None | V-2 12.73.1 107 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : | Each | 46.2 | 46.2 | 4.0 | False | None | None | False | None | False | 184.8 | 0 | 2995083 | 99592 | None | V-2 8.33.2 Pg. 46 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 144.9 | 144.9 | 10.39 | False | None | None | False | None | False | 1505.511 | 0 | 2995014 | 99592 | None | Vol-6.Chapter-5.It No - 5.18.6.Page No.17of105 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63Amps DP | Each | 1102.0 | 1102.0 | 2.0 | False | None | None | False | None | False | 2204.0 | 0 | 2995136 | 99592 | None | ELE P-1 It.No 5.18.5 Pg.13 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP | Each | 1060.0 | 1060.0 | 1.0 | False | None | None | False | None | False | 1060.0 | 0 | 2995178 | 99592 | None | V-2 12.72 107 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : | Each | 86.1 | 86.1 | 2.0 | False | None | None | False | None | False | 172.2 | 0 | 2995084 | 99592 | None | V-2 8.33.3 Pg. 47 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 145.95 | 145.95 | 25.31 | False | None | None | False | None | False | 3693.9945 | 0 | 2995015 | 99592 | None | Vol-6.Chapter-5.It No - 5.20.10.Page No.13 of 47 | Supplying,fixingandwiringResidualcurrentcircuitbreaker(RCCB)240/450V upto 300mA sensitivity on existing wood/ panel board. 63 Amps 4 pole | Each | 5545.0 | 5545.0 | 1.0 | False | None | None | False | None | False | 5545.0 | 0 | 2995137 | 99592 | None | ELE P-1 It.No 12.19.3 Pg.40 | Supplying and fixing of Electronic Ballast suitable for T5 Lamp with housing made of Pre-coated steel/PC, Operating voltage range from 180V to 265V, 50Hz AC power Supply flicker free warm start with over voltage protection, Inrush current protection, De-activated lamp protection& End of Lamp life protection with PF 0.95 & TC(degC) 65 deg C compliance to EN 61347-2-3 (Safety), EN60929(Performance), EN55015(EMI/RFI), EN61000-3-2 (Harmonics), EN 61547 (Surge). Operating voltage range from 180V to 265V, 50Hz AC power Supply (Part-I ELE I.No 12.9.3 Pg.No 40) 1 X 24W | Each | 925.0 | 925.0 | 3.0 | False | None | None | False | None | False | 2775.0 | 0 | 2995085 | 99592 | None | V-2 9.17.2 Pg. 61 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. | Sqm | 1233.75 | 1233.75 | 28.0 | False | None | None | False | None | False | 34545.0 | 0 | 2995016 | 99592 | None | Vol-6.Chapt-5.It No - 5.35.Pg No.19 of 105 | Supplying,fixingandwiringElectronicTrivectorMeter(ETV)5to32/63Athreephase4wirewholecurrentclass-1AccuracyEnergyMeter. | Each | 5705.0 | 5705.0 | 1.0 | False | None | None | False | None | False | 5705.0 | 0 | 2995138 | 99592 | None | ELE P-1 It.No 6.3.1 Pg.30 | Supplying capacitor type 48" sweep ceiling fan complete with down rod blades , shackle canopies etc suitable for operation on 230V 50 cycles single phase AC supply conforming to ISS - 374 - 1979 and with double ball bearing system 48" Sweep (1200 mm) Regular model | Each | 2984.0 | 2984.0 | 2.0 | False | None | None | False | None | False | 5968.0 | 0 | 2995086 | 99592 | None | V-2 12.12 Pg. 99 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 130412.1 | 130412.1 | 0.14 | False | None | None | False | None | False | 18257.694 | 0 | 2995017 | 99592 | None | Vol-6.Chapter-5.It No - 5.44.1.Pg No.21 of 105 | Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 300mmx300mmx214mm | Each | 4512.0 | 4512.0 | 1.0 | False | None | None | False | None | False | 4512.0 | 0 | 2995139 | 99592 | None | ELE P-1 It.No 6.1 Pg.30 | Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply | Each | 1492.0 | 1492.0 | 1.0 | False | None | None | False | None | False | 1492.0 | 0 | 2995087 | 99592 | None | V-2 12.51 Pg. 104 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | Sqm | 1066.8 | 1066.8 | 2.0 | False | None | None | False | None | False | 2133.6 | 0 | 2995018 | 99592 | None | Vol-6.Chapter-6.It No - 6.3.1.Page No.30 of 105 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200mm) Regular model | Each | 2984.0 | 2984.0 | 6.0 | False | None | None | False | None | False | 17904.0 | 0 | 2995140 | 99592 | None | ELE P-1 It.No 12.2.1 Pg.48 | Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws | Each | 246.0 | 246.0 | 1.0 | False | None | None | False | None | False | 246.0 | 0 | 2995088 | 99592 | None | V-2 12.57.6 Pg. 105 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification. 35 mm thick both side commercial ( SR for Buildings VOL II for the year 2021-22. I. No. 12.57.6 P.No. 106) | Sqm | 3488.1 | 3488.1 | 4.62 | False | None | None | False | None | False | 16115.022 | 0 | 2995019 | 99592 | None | Vol-6.Chapter-6.It No - 6.5.2.Page No.30 of 105 | Supplying wall mounting fan suitable to operate at singlephase 230v A.C. supply 400mm Sweep | Each | 3212.0 | 3212.0 | 2.0 | False | None | None | False | None | False | 6424.0 | 0 | 2995141 | 99592 | None | ELE P-1 It.No 13.7.1 Pg.56 | Fixing all types and all capacities fluorescent / false ceiling /spot light / CFL fitting indoors on the wall / ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires . Required nos of round blocks and clamps | Each | 122.0 | 122.0 | 3.0 | False | None | None | False | None | False | 366.0 | 0 | 2995089 | 99592 | None | V-2 11.11.1 Pg. 79 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and 12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). | Kg | 155.4 | 155.4 | 189.0 | False | None | None | False | None | False | 29370.6 | 0 | 2995020 | 99592 | None | Vol-6.Chapter-11.It No - 11.3.2.Pg No.43 of 105 | Supplying of ......feet - PVC Batten with integrated LED tube.....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED Light fighting 1 x4'- 20/22 w | Each | 690.0 | 690.0 | 8.0 | False | None | None | False | None | False | 5520.0 | 0 | 2995142 | 99592 | None | ELE P-1 It.No 13.10 Pg.57 | Fixing of Wall/ ceiling fan of all capacities and all types to the existing hook together with supplying and fixing a 5 A ceiling rose , necessary length of 23/0.0076 inch PVC insulated twin twisted copper wire and wiring complete | Each | 171.0 | 171.0 | 2.0 | False | None | None | False | None | False | 342.0 | 0 | 2995090 | 99592 | None | V-2 11.34B Pg. 86 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. | Kg | 192.15 | 192.15 | 189.0 | False | None | None | False | None | False | 36316.35 | 0 | 2995021 | 99592 | None | Vol-6.Chapter-13.It No - 13.7.1.Pg No.56 of 105 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders | Each | 122.0 | 122.0 | 6.0 | False | None | None | False | None | False | 732.0 | 0 | 2995143 | 99592 | None | ELE P-1 It.No 13.14 Pg.45 | Fixing one exhaust fan in the nitch already left in the wall with bolts & nuts and a 5 Amps, ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire of approved make with wire mesh and any frame if required | Each | 492.0 | 492.0 | 1.0 | False | None | None | False | None | False | 492.0 | 0 | 2995091 | 99592 | None | V-2 12.61 Pg. 105 | Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete. | Nos | 1039.5 | 1039.5 | 2.0 | False | None | None | False | None | False | 2079.0 | 0 | 2995022 | 99592 | None | Vol-6.Chapter-13.It No - 13.7.2.Pg No.56 of 105 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. Using necessary length of G.I. chain | Each | 263.0 | 263.0 | 8.0 | False | None | None | False | None | False | 2104.0 | 0 | 2995144 | 99592 | None | ELE P-1 ,It No.13.1.2,Pg.56 | Supplying and fixing 32 mm dia class A GI pipe bracket up to 2 mts long bent at suitable angle and fixing to this bracket 70 W MH street light fitting on wall using suitable clamps, bolts and nuts and wiring using suitable capacities of wires complete | m | 1045.0 | 1045.0 | 3.5 | False | None | None | False | None | False | 3657.5 | 0 | 2995092 | 99592 | None | V-2 12.74.1 Pg. 107 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm | Nos | 107.1 | 107.1 | 6.0 | False | None | None | False | None | False | 642.6 | 0 | 2995023 | 99592 | None | Vol-6.Chapter-13.It No - 13.10.Pg No.57 of 105 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 171.0 | 171.0 | 6.0 | False | None | None | False | None | False | 1026.0 | 0 | 2995145 | 99592 | None | ELEBESCOM P-3 51.04 23 | Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified | Nos | 2172.0 | 2172.0 | 1.0 | False | None | None | False | None | False | 2172.0 | 0 | 2995093 | 99592 | None | V-2 12.58 Pg. 105 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. | Each | 126.0 | 126.0 | 4.0 | False | None | None | False | None | False | 504.0 | 0 | 2995024 | 99592 | None | Vol-6.Chapter-13.It No -13.11.Pg No.57of105 | Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. | Each | 315.0 | 315.0 | 2.0 | False | None | None | False | None | False | 630.0 | 0 | 2995146 | 99592 | None | ELEBESCOM P-3 51.05 23 | Bentonite clay slurry for earthing in 50 Kg Bag | Nos | 368.0 | 368.0 | 1.0 | False | None | None | False | None | False | 368.0 | 0 | 2995025 | 99592 | None | ES P3 .Sl 201.I.32.05.Code No.287206.Page No.13.81 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) | Km | 141842.0 | 141842.0 | 0.05 | False | None | None | False | None | False | 7092.1 | 0 | 2995094 | 99592 | None | V-2 12.73.1 Pg. 106 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : | Each | 46.2 | 46.2 | 4.0 | False | None | None | False | None | False | 184.8 | 0 | 2995147 | 99592 | None | ELE P-1 , It.No..5.30 Pg.19 | Supplying, fixing and wiring Electronic Trivector Meter (ETV)5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter. | Each | 1380.0 | 1380.0 | 1.0 | False | None | None | False | None | False | 1380.0 | 0 | 2995026 | 99592 | None | ES SL .167.Item.No.20.05.Page No 52.81 | Transporting Cable from Store to work spot including loading and unloading (including Crane and other equipment charges if any) LT Cable 2.5 to 25 Sqmm (Single/3.5/4 Core) | Km | 1187.0 | 1187.0 | 0.05 | False | None | None | False | None | False | 59.35 | 0 | 2995095 | 99592 | None | V-2 12.72 Pg. 106 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : | Each | 86.1 | 86.1 | 4.0 | False | None | None | False | None | False | 344.4 | 0 | 2995148 | 99592 | None | ELE P-1 , It.No.5.7.3,Pg. 14 | Supply & Fixing Porcelaine fuse Channel with cut out on existing box using necessary nuts, bolts etc complete .a) 63 Amps | Each | 401.0 | 401.0 | 2.0 | False | None | None | False | None | False | 802.0 | 0 | 2995027 | 99592 | None | Vol-6.Chapter-2.It No -2.5.2.Page No.6 of 105 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to table 3 class 5 of IS:8130-1984 and (Virgin) PVC insulation and sheathed suitable for working voltage upto 1100Volts as per IS-694:1990 3C X 1.5Sq.mm | Mtr | 72.0 | 72.0 | 96.0 | False | None | None | False | None | False | 6912.0 | 0 | 2995028 | 99592 | None | Vol-6.Chapter-1.It No - 1.1.4.Page No.2of105 | Open Conduit System Supplying heavy gauge PVC conduit pipe 40mm dia 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. | Mtr | 149.0 | 149.0 | 50.0 | False | None | None | False | None | False | 7450.0 | 0 | 2995029 | 99592 | None | Vol-6.Chapter-11.It No- 1.9.3.Page No.46of105 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation.Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material,delivering superior light output. Rated life Burning Hrs 50000hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency130lm/w, nominal CRI75. Luminaire manufacturer should have inhouse facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/Lumileds /Osram make LED Source LED Floodlight 120W | Each | 10757.0 | 10757.0 | 8.0 | False | None | None | False | None | False | 86056.0 | 0 | 2995030 | 99592 | None | Vol-6.Chapter-4.It No - 4.5.1.Page No.13 of 105 | Fabrication, Supplying, Erection, Testing and Commissioning of ……Mtrs long polygon high mast with Single / Multiple telescopic sections having, ( minimum overlap distance of 1.5 times of top section) thickness as per BSEN 10025 grade S 355 JO /ASTM A572-50 steel sheet plate for shaft suitable to withstand a wind velocity of 47 m/sec as per IS 875 part 3(as per GA Drawing).Base plate as per IS 2062/ASTM A572-50. The mast shall be Galvanized in single Hot-dip as per BSEN ISO 1461/ASTM A123 with an average 70 microns as per IS 2629, and welded as per BS 5135 Single L-Seam joint. The mast shall have 2way head frame with die cast LM-6 pulleys, stainless steel axle, Phosphorus Bronze bearing bush press-fitted with separate guides for 2 runs of 5mm dia, stainless steel wire rope of AISI 304grade 7/19-core, (Factor of Safety as per TR no-7). 2.5sqmm EPR insulated PCP sheathed trailing power cable housed inside the bottom shaft of mast with door having locking arrangement. The mast shall have power tool operating on 230/ 415V, 50Hz, 1/3 phases reversible geared motor. The mast shall have lantern of 2 segments, suitable dia with max load carrying capacity as per IS 1239. The mast shall be erected on existing RCC footing. The mast shall be supplied with 3mm thick template, lightning arrester of 1.2m length galvanized pipe with top arrow fitted on top of the head frame cover and GLS type aviation twin lamps fitting with wiring complete. ( excluding foundation) as per technical data. 12Mtrs/12.5Mtrs - Top 100mm and bottom 310 mm dia | Each | 131000.0 | 131000.0 | 1.0 | False | None | None | False | None | False | 131000.0 | 0 | 2995031 | 99592 | None | Vol-6.Chapter-4.It No - 4.6.6.Page No.13 of105 | Supplying, and fixing of Hot dip Galvanized M.S.Bracket suitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. Double Arm Bracket with 2000mm Standard 40/50MM dia | Each | 3800.0 | 3800.0 | 1.0 | False | None | None | False | None | False | 3800.0 | 0 | 2995032 | 99592 | None | Vol-6.Chapter-5.It No - 5.13.3.Page No.11 of 47 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 60-70Amps | Each | 4926.0 | 4926.0 | 1.0 | False | None | None | False | None | False | 4926.0 | 0 | 2995033 | 99592 | None | Vol-6.Chapter-5.It No - 5.18.4.Page No.17 of 105 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 Amps DP | Each | 739.0 | 739.0 | 4.0 | False | None | None | False | None | False | 2956.0 | 0 | 2995034 | 99592 | None | Vol-6.Chapter-5.It No - 5.44.4.Page No.21 of 105 | Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 600mmx600mmx170mm | Each | 14520.0 | 14520.0 | 1.0 | False | None | None | False | None | False | 14520.0 | 0 | 2995035 | 99592 | None | Vol-6.Chapter-5.It No - 5.48.Page No.21of 105 | Supplying and fixing Microprocessor based Electronic timer (without contactor, Din Mounting using necessary bolts, nuts and washers etc.,.) 3-120sec setting. | Each | 4843.0 | 4843.0 | 1.0 | False | None | None | False | None | False | 4843.0 | 0 | 2995036 | 99592 | None | Es P3.Sl 199.I No.32.03.Code No.287205.P No.13.81 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm) | Km | 118004.0 | 118004.0 | 0.1 | False | None | None | False | None | False | 11800.4 | 0 | 2995037 | 99592 | None | ES Part-IV.Sl.No.167.Item.No.20.05.Page No.52.81 | Transporting Cable from Store to work spot including loading and unloading (including Crane and other equipment charges if any) LT Cable 2.5 to 25 Sqmm (Single/3.5/4 Core) | Km | 1187.0 | 1187.0 | 0.1 | False | None | None | False | None | False | 118.7 | 0 | 2995038 | 99592 | None | DSR 2023-24.Vol-1.Item.No.1.6.1.Page No.06 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m | Mtr | 508.2 | 508.2 | 15.0 | False | None | None | False | None | False | 7623.0 | 0 | 2995039 | 99592 | None | DSR 2023-24.Vol-1.Item.No.1.10.Page No.07 | Refilling available earth around trenches/pipelines, cables in layers notexceeding 20 cms in depth, compacting each deposited layer by ramming afterwatering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labourcomplete as per specifications | Cum | 168.0 | 168.0 | 15.0 | False | None | None | False | None | False | 2520.0 | 0 | 2995040 | 99592 | None | Es P3.S 392.I No1.04. .281685.Page No.23 . 81 | Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified | No | 2172.0 | 2172.0 | 2.0 | False | None | None | False | None | False | 4344.0 | 0 | 2995041 | 99592 | None | ES.P-3 SL 392.I No.51.05. .281685.Page No.23 . 81 | Bentoetite Clay Slurry for Earthing in 50kgs Bag | Bag | 368.0 | 368.0 | 2.0 | False | None | None | False | None | False | 736.0 | 0 | 2995042 | 99592 | None | DSR 2014-15,Pg.-101, It No- 15.6.1 | Supply, installation, testing and commissioning of booster amplifier with power handling of 250 to 300 watt RMS 4ohms Dual and 100/70 volt output on bridge mode single channel Rack mountable Specs: frequency response : 20 htz to 20khtz | No | 27550.0 | 27550.0 | 1.0 | False | None | None | False | None | False | 27550.0 | 0 | 2995043 | 99592 | None | DSR 2014-15,Pg.-101, It No- 15.7.1 | Supply, installation, testing and commissioning of 4 to 6 Channel 4 mic/line input mixer with 2/3 band semi parametric eq 2 bus and 2 aux 2 stereo return. | No | 12800.0 | 12800.0 | 1.0 | False | None | None | False | None | False | 12800.0 | 0 | 2995044 | 99592 | None | DSR 2014-15,Pg.-101, It No- 15.8.2 | Supply, installation, testing and commissioning of dual channel 31 band Graphic Equalizer with 31 band Controls on each Channel filters per channel 6db to 12 db. boost/cut multi band manually selectable parametric equalizer dual channel. | No | 18200.0 | 18200.0 | 1.0 | False | None | None | False | None | False | 18200.0 | 0 | 2995045 | 99592 | None | DSR 2014-15,Pg.-101, It No- 15.9.2 | Supply, installation, testing and commissioning of cardioids handheld/collar VHF/UHF Economical wireless microphone Transmitter and receiver with selectable carrier Frequency from VHF/UHF 179-279 MHz 575 MHz to 875 MHz | No | 5300.0 | 5300.0 | 4.0 | False | None | None | False | None | False | 21200.0 | 0 | 2995046 | 99592 | None | DSR 2014-15,Pg.-102, It No- 15.10 | System Racks Supply, installation, testing and commissioning of 19" 20/15U 580 Depth system rack with Front glass door , back door with heavy duty wheels with cable manager and power strip and termination plates for signal and speaker out system. | No | 12800.0 | 12800.0 | 1.0 | False | None | None | False | None | False | 12800.0 | 0 | 2995047 | 99592 | None | DSR 2014-15,Pg.-102, It No- 15.11 | Speaker Cables Supply, installation, testing and commissioning professional grade 2.5 sq mm TIN coated low loss 2 core multi strand Oxidation Free speaker cable including, lead and lifts, loading and unloading, cost of conveyance for all the materials with the accessories | Mtr | 38.0 | 38.0 | 150.0 | False | None | None | False | None | False | 5700.0 | 0 | 2995048 | 99592 | None | DSR 2014-15,Pg.-102, It No- 15.12 | Connectors and I/C Cables Supply, installation, testing and commissioning of professional grade audio connectors for inter connection cables with in the rack and other units as well auditorium as required including charges for labour, lead and lifts, loading and unloading, cost of conveyance for all the materials with the accessories required for completion as per the detailed specifications. Neutrick/SR/Amphenol /nT/MX /Equivalent. | Set | 240.0 | 240.0 | 10.0 | False | None | None | False | None | False | 2400.0 | 0 | 2995049 | 99592 | None | Vol-6.Chapter-11.It No-11.9.1.Page No.46of105 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation.Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material,delivering superior light output. Rated life Burning Hrs 50000hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains,Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency130lm/w,nominal CRI 75. Luminaire manufacturer should have inhouse facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/Lumileds /Osram make LED Source.LED Floodlight 70W | Each | 6768.0 | 6768.0 | 8.0 | False | None | None | False | None | False | 54144.0 | 0 | 2995050 | 99592 | None | PWD Civil SR 2023-24 Vol-1 P.No.06 It.No.1.6.1 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m | Mtr | 508.2 | 508.2 | 15.0 | False | None | None | False | None | False | 7623.0 | 0 | 2995051 | 99592 | None | PWD Civil SR 2023-24 Vol-1 P.No.18 It.No.2.11 h | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / softannealed steel wire and other ancilary operations complete as per drawing andtechnical specification All other type of structures | t | 82961.55 | 82961.55 | 0.034 | False | None | None | False | None | False | 2820.6927 | 0 | 2995052 | 99592 | None | PWD Civil SR 2023-24 Vol-1 P.No.15 It.No.2.1.2 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 2.5 | False | None | None | False | None | False | 14868.0 | 0 | 2995053 | 99592 | None | PWD Civil SR 2023-24 Vol-1 P.No.16 It.No.2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7185.15 | 7185.15 | 3.0 | False | None | None | False | None | False | 21555.45 | 0 | 2995054 | 99592 | None | Appendix-I in Volume-1 ofPg..-111 | Additional for formwork, Centering & Scaffolding for Sl No 9 : Columns As per Appendix-I in Volume-1 of page No.-111 (@ 70% of Revised Finished Rate) | Cum | 5029.61 | 5029.61 | 3.0 | False | None | None | False | None | False | 15088.83 | 0 |
|
|
---|