tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1710236117000 | 0 | None | None | Buildings | GROUND FLOOR | 2920336.58 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3002860 | 100181 | None | Item No. 1.12 Page No. | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth | Cum | 97.85 | 97.85 | 37.56 | False | None | None | False | None | False | 3675.246 | 0 | 3002861 | 100181 | None | Item no1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 105.06 | 105.06 | 150.56 | False | None | None | False | None | False | 15817.8336 | 0 | 3002862 | 100181 | None | Item No.1.15.2 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting depth exceeding 1.5m , but not exceeding 3m | Cum | 437.75 | 437.75 | 16.73 | False | None | None | False | None | False | 7323.5575 | 0 | 3002863 | 100181 | None | ITEM NO. 4.1 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, GROUND excavation top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 ltr/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 121.54 | 121.54 | 102.54 | False | None | None | False | None | False | 12462.7116 | 0 | 3002864 | 100181 | None | item No.1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 273.98 | 273.98 | 150.53 | False | None | None | False | None | False | 41242.2094 | 0 | 3002865 | 100181 | None | Item No. 1.8 P.No. 7 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 488.22 | 488.22 | 111.36 | False | None | None | False | None | False | 54368.1792 | 0 | 3002866 | 100181 | None | Item No. 2.1.3 Pl.No. 15 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to coplete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6168.67 | 6168.67 | 24.3 | False | None | None | False | None | False | 149898.681 | 0 | 3002867 | 100181 | None | 2.2.3 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Isolated Footing including cost of formwork, centering & scaffolding 8% for isolated footing. loading and unloading charges etc. Complete as directed as per specifcation and direction of Engineer in-charge of the work | Cum | 7048.17 | 7048.17 | 19.98 | False | None | None | False | None | False | 140822.4366 | 0 | 3002868 | 100181 | None | 2.2.3 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Combined Footing. including cost of formwork, centering & scaffolding 3% for combined footing. loading and unloading charges etc. Complete as directed as per specifcation and direction of Engineer in-charge of the work | Cum | 6721.86 | 6721.86 | 19.84 | False | None | None | False | None | False | 133361.7024 | 0 | 3002869 | 100181 | None | Item No.2.4.3 Page No.16 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Columns. s including cost of formwork,centering and scaffolding 70 % for columns up to plinth level loading and unloading charges etc.Complete as directed as per specifcation and direction of Engineer in-charge of the work. | Cum | 11094.34 | 11094.34 | 5.41 | False | None | None | False | None | False | 60020.3794 | 0 | 3002870 | 100181 | None | Item No. 2.5.2 Page No.17 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates Plinth Beams, Curtain wall. Including cost of Formwork.s including cost of formwork,
centering and scaffolding 70 % for columns above plinth level loading and unloading charges etc.Complete as directed as per specifcation and direction of Engineer in-charge of the work. | Cum | 11982.09 | 11982.09 | 7.79 | False | None | None | False | None | False | 93340.4811 | 0 | 3002871 | 100181 | None | Item No.2.4.3 Page No. 16 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Plinth Beams. including cost of formwork,
centering & scaffloding 50% for plinth beams loading and unloading charges etc. Complete as directed as perspecifcation and direction of Engineer in-charge of the work | Cum | 9789.12 | 9789.12 | 5.31 | False | None | None | False | None | False | 51980.2272 | 0 | 3002872 | 100181 | None | Item No. 2.4.3 Page No. 16 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Curtain wall. including cost of formwork,
centering & scaffloding 10% for curtain wall loading and unloading charges etc. Complete as directed as per specifcation and direction of Engineer in-charge of the work | Cum | 7178.69 | 7178.69 | 15.68 | False | None | None | False | None | False | 112561.8592 | 0 | 3002873 | 100181 | None | Item No. 2.5.2, P.No.16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Beams & Lintel. including cost of formwork,
centering & scaffloding 60% for beams and lintel. loading and unloading charges etc. Complete as directed as per specifcation and direction of Engineer in-charge of the work | Cum | 11277.26 | 11277.26 | 9.91 | False | None | None | False | None | False | 111757.6466 | 0 | 3002874 | 100181 | None | Item No 2.5.2 Page No.15 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Roof Slab. including cost of formwork,
centering & scaffloding 50% for roof slab loading and unloading charges etc. Complete as directed as per specifcation and direction of Engineer in-charge of the work | Cum | 10572.44 | 10572.44 | 12.96 | False | None | None | False | None | False | 137018.8224 | 0 | 3002875 | 100181 | None | ITEM NO.2.5.2 Page No. 16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Sill. including cost of formwork,
centering & scaffloding 3% for sill loading and unloading charges etc. Complete as directed as per specifcation and direction of Engineer in-charge of the work | Cum | 7259.74 | 7259.74 | 0.79 | False | None | None | False | None | False | 5735.1946 | 0 | 3002876 | 100181 | None | ITEM NO.2.5.2 P.No.16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. including cost of formwork,
centering & scaffloding 45% for Chejja loading and unloading charges etc. Complete as directed as per specifcation and direction of Engineer in-charge of the work | Cum | 10220.02 | 10220.02 | 1.19 | False | None | None | False | None | False | 12161.8238 | 0 | 3002877 | 100181 | None | Ite No. 2.11a Page No. 18 | Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings | t | 92140.71 | 92140.71 | 8.48 | False | None | None | False | None | False | 781353.2208 | 0 | 3002878 | 100181 | None | Item No. 6.8 Page No. 14 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8208.07 | 8208.07 | 26.45 | False | None | None | False | None | False | 217103.4515 | 0 | 3002879 | 100181 | None | Item No. 12.13.1, Page No. 100 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves ( excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications | Cum | 101779.45 | 101779.45 | 0.39 | False | None | None | False | None | False | 39693.9855 | 0 | 3002880 | 100181 | None | I.No. 12.51 Page No. 104 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | Nos | 1046.48 | 1046.48 | 2.0 | False | None | None | False | None | False | 2092.96 | 0 | 3002881 | 100181 | None | I No. 10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete Fastener with threaded dia 12 mm | Nos | 61.8 | 61.8 | 12.0 | False | None | None | False | None | False | 741.6 | 0 | 3002882 | 100181 | None | I No. 12.15 Page No. 100 | Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ) | Sqm | 7667.32 | 7667.32 | 5.0 | False | None | None | False | None | False | 38336.6 | 0 | 3002883 | 100181 | None | I No. 12.57.5 Page No. 105 | Providing and fixing 35 mm thick one side teak and one side commercial flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets ( core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 ( part-I) 1991. from manufacturer complete as per spcification | m | 4013.91 | 4013.91 | 0.9 | False | None | None | False | None | False | 3612.519 | 0 | 3002884 | 100181 | None | I No. 12.9 Page No. 110 | Providing & fixing of 3 track x 2 panel sliding windows made out of multi chambered UPVC Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T and Ps shall not be made) | Sqm | 6936.02 | 6936.02 | 12.0 | False | None | None | False | None | False | 83232.24 | 0 | 3002885 | 100181 | None | I No. 12.85 P No. 109 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 5890.57 | 5890.57 | 0.9 | False | None | None | False | None | False | 5301.513 | 0 | 3002886 | 100181 | None | I.No. 11.34B P .No. 86 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. | Kg | 188.49 | 188.49 | 270.9 | False | None | None | False | None | False | 51061.941 | 0 | 3002887 | 100181 | None | I.No.8.1.2 P.No.41 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 248.23 | 248.23 | 139.66 | False | None | None | False | None | False | 34667.8018 | 0 | 3002888 | 100181 | None | I.No. 8.51 P.No.50 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 103.0 | 103.0 | 287.11 | False | None | None | False | None | False | 29572.33 | 0 | 3002889 | 100181 | None | I.No. 8.2.2 P.No.41 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Out side) | Sqm | 287.37 | 287.37 | 199.76 | False | None | None | False | None | False | 57405.0312 | 0 | 3002890 | 100181 | None | I.No. 9.2 P.No. 59 | Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1 2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed 2 litre per 50 kg of cement or as per direction of Engineer incharge. | Sqm | 824.0 | 824.0 | 33.64 | False | None | None | False | None | False | 27719.36 | 0 | 3002891 | 100181 | None | I.No. 9.24 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with whitecement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, Lakared, River Pink, Orissa Blue or equivalent. | Sqm | 2937.56 | 2937.56 | 92.49 | False | None | None | False | None | False | 271694.9244 | 0 | 3002892 | 100181 | None | 10.1.1 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. | Sqm | 4126.18 | 4126.18 | 4.44 | False | None | None | False | None | False | 18320.2392 | 0 | 3002893 | 100181 | None | Item No, 11.28 Page No. 34 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessoris such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 581.95 | 581.95 | 50.88 | False | None | None | False | None | False | 29609.616 | 0 | 3002894 | 100181 | None | Item No, 8.33.1 Page No. 46 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied 0.75 ltr 10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 162.74 | 162.74 | 287.11 | False | None | None | False | None | False | 46724.2814 | 0 | 3002895 | 100181 | None | Item No, 8.3 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paer smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 179.22 | 179.22 | 204.76 | False | None | None | False | None | False | 36697.0872 | 0 | 3002896 | 100181 | None | I,No, 8.33.3 Page No, 47 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 143.17 | 143.17 | 12.9 | False | None | None | False | None | False | 1846.893 | 0 |
| 1710236117000 | 0 | None | None | Buildings | First Floor | 1984607.8 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3002897 | 100182 | None | Item No, 2.5.2 Page No, 16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.including cost of formwork,
centering & scaffloding 70 % for columns loading and unloading charges etc. Complete as directed as per specifcation and direction of Engineer in-charge of the work | Cum | 12052.58 | 12052.58 | 9.99 | False | None | None | False | None | False | 120405.2742 | 0 | 3002898 | 100182 | None | I.No.2.5.2 P.No.16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. including cost of formwork,centering & scaffloding 60 % for columns loading and unloading charges etc. Complete as directed as per specifcation and direction of Engineer in-charge of the work | Cum | 11347.75 | 11347.75 | 9.84 | False | None | None | False | None | False | 111661.86 | 0 | 3002899 | 100182 | None | Item No. 2.5.2 Page No. 16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. including cost of formwork,centering 50% for roof slab loading and unloading charges etc. Complete as directed as perspecifcation and direction of Engineer in-charge of the work | Cum | 10642.92 | 10642.92 | 12.96 | False | None | None | False | None | False | 137932.2432 | 0 | 3002900 | 100182 | None | I.NO. 2.5.2 P.No.16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. including cost of formwork, centering 3% for sill loading and unloading charges etc. Complete as directed as per specifcation and direction of Engineer in-charge of the works | Cum | 7330.22 | 7330.22 | 0.86 | False | None | None | False | None | False | 6303.9892 | 0 | 3002901 | 100182 | None | Item No. 2.5.2 Page No. 16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. including cost of formwork, centering 45% for Chejja loading and unloading charges etc. Complete as directed as per specifcation and direction of Engineer in-charge of the work | Cum | 10290.5 | 10290.5 | 1.19 | False | None | None | False | None | False | 12245.695 | 0 | 3002902 | 100182 | None | Item No. 2.11a P.No.18 | Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings | t | 93062.12 | 93062.12 | 4.62 | False | None | None | False | None | False | 429946.9944 | 0 | 3002903 | 100182 | None | Item no. 6.8 , P.No.14 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8290.15 | 8290.15 | 38.19 | False | None | None | False | None | False | 316600.8285 | 0 | 3002904 | 100182 | None | Item No. 12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves ( excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications | Cum | 102797.24 | 102797.24 | 0.55 | False | None | None | False | None | False | 56538.482 | 0 | 3002905 | 100182 | None | Item No. 12.51 P.No. 104 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | Nos | 1056.94 | 1056.94 | 3.0 | False | None | None | False | None | False | 3170.82 | 0 | 3002906 | 100182 | None | I.No. 10.6.3, P.No. 69 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete Fastener with threaded dia 12 mm | Nos | 62.42 | 62.42 | 18.0 | False | None | None | False | None | False | 1123.56 | 0 | 3002907 | 100182 | None | Item No.12.15 P.No.100 | Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ) | Sqm | 7743.99 | 7743.99 | 5.0 | False | None | None | False | None | False | 38719.95 | 0 | 3002908 | 100182 | None | Item No. 12.57.5 P.No. 105 | Providing and fixing 35 mm thick one side teak and one side commercial flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets ( core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 ( part-I) 1991. from manufacturer complete as per spcification | m | 4054.05 | 4054.05 | 1.8 | False | None | None | False | None | False | 7297.29 | 0 | 3002909 | 100182 | None | Item No. 12.9 P.No.110 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) | Sqm | 7005.38 | 7005.38 | 12.0 | False | None | None | False | None | False | 84064.56 | 0 | 3002910 | 100182 | None | Item No. 12.85 P.No.109 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 5949.48 | 5949.48 | 0.9 | False | None | None | False | None | False | 5354.532 | 0 | 3002911 | 100182 | None | Item No. 11.34B P.No.86 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. | Kg | 190.37 | 190.37 | 270.9 | False | None | None | False | None | False | 51571.233 | 0 | 3002912 | 100182 | None | Item No. 8.1.2 P.No. 41 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 250.71 | 250.71 | 151.22 | False | None | None | False | None | False | 37912.3662 | 0 | 3002913 | 100182 | None | Item No. 8.51 P.No.50 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 104.03 | 104.03 | 298.69 | False | None | None | False | None | False | 31072.7207 | 0 | 3002914 | 100182 | None | Item No. 8.2.2 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Out side) | Sqm | 290.24 | 290.24 | 242.97 | False | None | None | False | None | False | 70519.6128 | 0 | 3002915 | 100182 | None | Item No. 9.24, P.No. 63 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with whitecement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, Lakared, River Pink, Orissa Blue or equivalent. | Sqm | 2966.94 | 2966.94 | 87.58 | False | None | None | False | None | False | 259844.6052 | 0 | 3002916 | 100182 | None | Item No. 10.1.1 P.No. 69 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. | Sqm | 4167.44 | 4167.44 | 3.0 | False | None | None | False | None | False | 12502.32 | 0 | 3002917 | 100182 | None | Item No. 15.1 P.No.151 | Newly Constructed Bathroom/toilet/balcony/utility with Cementatius Waterproof coating - Below 300 m2: Providing and Applying CFTRI approved two component flexible polymer modified acrylic cementitious waterproofing coating with a mix ratio of (1 Liquid: 2 Powder), to the RCC surface like bathroom, toilet, balcony & utility area applied @ 1.7kg/m2 in 2 coats to achieve 1mm DFT, having Elongation at break 50% as per ASTM D 412, Tensile strength 1N/mm2 as per ASTM D 412, Adhesion strength: 0.80 N/mm2 as per ASTM D 4541, crack bridging upto 1mm as per ASTM C 836, Water penetration (5 bar pressure) as per BS EN 12390. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 45 gsm glass fibre mesh over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification. | Sqm | 381.79 | 381.79 | 108.96 | False | None | None | False | None | False | 41599.8384 | 0 | 3002918 | 100182 | None | Item No. 7.18 P.No.23 | Providing and laying cinder concrete in cement 115 ( 1 cement 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slopecompacting, including cost of materials, labour, curing complete as per specifications. | Cum | 2098.29 | 2098.29 | 1.2 | False | None | None | False | None | False | 2517.948 | 0 | 3002919 | 100182 | None | Item No. 9.11 P.No.60 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete | Sqm | 924.83 | 924.83 | 4.0 | False | None | None | False | None | False | 3699.32 | 0 | 3002920 | 100182 | None | Item No. 10.14 P.No. 71 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. | Sqm | 1150.57 | 1150.57 | 14.91 | False | None | None | False | None | False | 17154.9987 | 0 | 3002921 | 100182 | None | Item No.11.28 P.No. 85 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessoris such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 587.77 | 587.77 | 50.88 | False | None | None | False | None | False | 29905.7376 | 0 | 3002922 | 100182 | None | Item No. 8.33.1 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied 0.75 ltr 10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 164.37 | 164.37 | 298.69 | False | None | None | False | None | False | 49095.6753 | 0 | 3002923 | 100182 | None | Item No. 8.3 P.No. 46 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paer smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 181.01 | 181.01 | 242.97 | False | None | None | False | None | False | 43979.9997 | 0 | 3002924 | 100182 | None | Item No. 4.33.3 P.No.47 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 144.6 | 144.6 | 12.9 | False | None | None | False | None | False | 1865.34 | 0 |
| 1710236117000 | 0 | None | None | Buildings | SANITARY AND WATER SUPPLY | 414508.88 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3002925 | 100183 | None | Item no. 13.3.1 | Providing and fixing brass stop cock of approved quality :15 mm nominal bore | Each | 307.97 | 307.97 | 4.0 | False | None | None | False | None | False | 1231.88 | 0 | 3002926 | 100183 | None | 13.20.2 | Providing and fixing PTMT pillar cock of approved quality and colour. 15 mm nominal bore, 125 mm long foam flow, weighing not less than 120 gms | Each | 323.42 | 323.42 | 7.0 | False | None | None | False | None | False | 2263.94 | 0 | 3002927 | 100183 | None | 14.2.1 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlleddevice (handle lever), conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid | Each | 4983.14 | 4983.14 | 1.0 | False | None | None | False | None | False | 4983.14 | 0 | 3002928 | 100183 | None | 14.7.8 | White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow including operated levers | Each | 4236.39 | 4236.39 | 7.0 | False | None | None | False | None | False | 29654.73 | 0 | 3002929 | 100183 | None | Item No. 14.8 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. | Each | 1465.69 | 1465.69 | 7.0 | False | None | None | False | None | False | 10259.83 | 0 | 3002930 | 100183 | None | Item No. 14.32.2 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mm | Each | 1048.54 | 1048.54 | 4.0 | False | None | None | False | None | False | 4194.16 | 0 | 3002931 | 100183 | None | 13.31.2 | Providing & fixing Chorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction Engineer in Charge.Exposed on wall - 20mm nominal dia pipes | Rmtr | 249.26 | 249.26 | 60.0 | False | None | None | False | None | False | 14955.6 | 0 | 3002932 | 100183 | None | 13.31.3 | Providing & fixing Chorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction Engineer in Charge.Exposed on wall - 25mm nominal dia pipes | Rmtr | 327.54 | 327.54 | 60.0 | False | None | None | False | None | False | 19652.4 | 0 | 3002933 | 100183 | None | 13.31.4 | Providing & fixing Chorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction Engineer in Charge.Exposed on wall - 32mm nominal dia pipes | Rmtr | 412.0 | 412.0 | 60.0 | False | None | None | False | None | False | 24720.0 | 0 | 3002934 | 100183 | None | 13.31.6 | Providing & fixing Chorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction Engineer in Charge.Exposed on wall - 50mm nominal dia pipes | Rmtr | 804.43 | 804.43 | 90.0 | False | None | None | False | None | False | 72398.7 | 0 | 3002935 | 100183 | None | 13.4.4 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :50 mm nominal bore | Each | 880.65 | 880.65 | 25.0 | False | None | None | False | None | False | 22016.25 | 0 | 3002936 | 100183 | None | 13.8.2.2 | Providing and fixing unplasticised PVC connection pipe with brass unions :45 cm length 20 mm nominal bore | Each | 113.3 | 113.3 | 25.0 | False | None | None | False | None | False | 2832.5 | 0 | 3002937 | 100183 | None | 13.34 | Providing and placing on terrace, polyethylene water storage tanks as per IS 12701 : 1996 with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes but without fittings and the base support for tank | l | 9.27 | 9.27 | 10000.0 | False | None | None | False | None | False | 92700.0 | 0 | 3002938 | 100183 | None | Item No.660 | PVC pipes of 8 Kg/cm2 for 140mm (3.097) | Rmtr | 469.68 | 469.68 | 109.2 | False | None | None | False | None | False | 51289.056 | 0 | 3002939 | 100183 | None | Item No. 664 | PVC pipes of 10 Kg/cm2 for 200mm | Rmtr | 1189.65 | 1189.65 | 30.0 | False | None | None | False | None | False | 35689.5 | 0 | 3002940 | 100183 | None | Item No. 672 | PVC pipes of 4 Kg/cm2 for 200mm(4.256) | Rmtr | 502.64 | 502.64 | 49.2 | False | None | None | False | None | False | 24729.888 | 0 | 3002941 | 100183 | None | 14.29 | Providing and fixing 100 mm sand cast Iron grating for gully trap. | Nos | 48.41 | 48.41 | 10.0 | False | None | None | False | None | False | 484.1 | 0 | 3002942 | 100183 | None | 13.22.1.2 | Providing and fixing PTMT grating of approved quality and colour 125 mm nominal dia | Nos | 45.32 | 45.32 | 10.0 | False | None | None | False | None | False | 453.2 | 0 |
| 1710236117000 | 0 | None | None | Buildings | Electrical works to the Kitchen Block and Dining Hall in First Floor I B at Nyamati Honnali Taluk. | 423531.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3002943 | 100184 | None | Item No. 1.1.1 | Open Conduit System
Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.
19/20 mm dia 2 mm thick | m | 69.0 | 69.0 | 550.0 | False | None | None | False | None | False | 37950.0 | 0 | 3002944 | 100184 | None | Item No. 1.1.2 | Open Conduit System
Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.25 mm dia 2 mm thick | m | 81.0 | 81.0 | 315.0 | False | None | None | False | None | False | 25515.0 | 0 | 3002945 | 100184 | None | Item No.1.3- 1.2.1 | Supplying heavy gauge PVC conduit pipe . mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary
19/20 mm dia 2 mm thick | m | 66.0 | 66.0 | 250.0 | False | None | None | False | None | False | 16500.0 | 0 | 3002946 | 100184 | None | Item No. 1.2.2 | Supplying heavy gauge PVC conduit pipe . mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25 mm dia 2 mm thick | m | 78.0 | 78.0 | 120.0 | False | None | None | False | None | False | 9360.0 | 0 | 3002947 | 100184 | None | Item No. 1.5-1.5.1 | Supplying and fixing PVC/metal conduit Deep junction box
19/20 mm deep Junction box | Each | 49.0 | 49.0 | 50.0 | False | None | None | False | None | False | 2450.0 | 0 | 3002948 | 100184 | None | Item No. 1.5.2 | Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction box | Each | 56.0 | 56.0 | 35.0 | False | None | None | False | None | False | 1960.0 | 0 | 3002949 | 100184 | None | Item No.1.13 | Supplying And Fixing Metal Fan Box with Round Hook | No | 117.0 | 117.0 | 30.0 | False | None | None | False | None | False | 3510.0 | 0 | 3002950 | 100184 | None | Item no. 2.1-2.1.1 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet
Short point upto 3Mtr from tapping point to out let via switch | Point | 285.0 | 285.0 | 50.0 | False | None | None | False | None | False | 14250.0 | 0 | 3002951 | 100184 | None | Item No. 2.1.2 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch | Point | 394.0 | 394.0 | 25.0 | False | None | None | False | None | False | 9850.0 | 0 | 3002952 | 100184 | None | Item No.2.1.3 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet Long point above 6Mtr upto 10Mtr from tapping point to out let via switch | Point | 570.0 | 570.0 | 20.0 | False | None | None | False | None | False | 11400.0 | 0 | 3002953 | 100184 | None | Item No.2.3-2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 mm2 | m | 26.0 | 26.0 | 850.0 | False | None | None | False | None | False | 22100.0 | 0 | 3002954 | 100184 | None | Item No. 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 mm2 | m | 42.0 | 42.0 | 1800.0 | False | None | None | False | None | False | 75600.0 | 0 | 3002955 | 100184 | None | Item No.2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 4 mm2 | m | 63.0 | 63.0 | 350.0 | False | None | None | False | None | False | 22050.0 | 0 | 3002956 | 100184 | None | Item No. 3.3-3.3.4 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete 8 Way | Each | 219.0 | 219.0 | 15.0 | False | None | None | False | None | False | 3285.0 | 0 | 3002957 | 100184 | None | 3.3.5 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete 10-12 way | Each | 261.0 | 261.0 | 10.0 | False | None | None | False | None | False | 2610.0 | 0 | 3002958 | 100184 | None | 3.3.6 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete 16 way | Each | 294.0 | 294.0 | 10.0 | False | None | None | False | None | False | 2940.0 | 0 | 3002959 | 100184 | None | Item No. 3.4-3.4.5 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 8 way | Each | 261.0 | 261.0 | 25.0 | False | None | None | False | None | False | 6525.0 | 0 | 3002960 | 100184 | None | Item No. 3.4.6 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12 way | Each | 319.0 | 319.0 | 10.0 | False | None | None | False | None | False | 3190.0 | 0 | 3002961 | 100184 | None | Item No.3.6-3.6.1 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293- 6A one way switch | Each | 102.0 | 102.0 | 100.0 | False | None | None | False | None | False | 10200.0 | 0 | 3002962 | 100184 | None | Item No. 3.6.3 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A Three way socket | Each | 171.0 | 171.0 | 10.0 | False | None | None | False | None | False | 1710.0 | 0 | 3002963 | 100184 | None | Item No. 3.6.4 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 Stepped Fan Regulator Two Module | Each | 357.0 | 357.0 | 30.0 | False | None | None | False | None | False | 10710.0 | 0 | 3002964 | 100184 | None | Item No.3.6.8 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 16A One way switch | Each | 180.0 | 180.0 | 10.0 | False | None | None | False | None | False | 1800.0 | 0 | 3002965 | 100184 | None | Item No.3.6.10 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 32A DP Switch | Each | 326.0 | 326.0 | 25.0 | False | None | None | False | None | False | 8150.0 | 0 | 3002966 | 100184 | None | Item No.3.6.11 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6/16A Universal socket | Each | 236.0 | 236.0 | 25.0 | False | None | None | False | None | False | 5900.0 | 0 | 3002967 | 100184 | None | 11.3-11.3.3 | Supplying of .feet -PVC Batten with integrated LED tube . W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition-LED light fitting 1 x 4' - 36/40 W | Each | 1269.0 | 1269.0 | 30.0 | False | None | None | False | None | False | 38070.0 | 0 | 3002968 | 100184 | None | Item No.6.4-6.4.1 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans)-48" Sweep 5 Star (1200 mm) | Each | 2677.0 | 2677.0 | 16.0 | False | None | None | False | None | False | 42832.0 | 0 | 3002969 | 100184 | None | 13.7-13.7.1 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps.-On wall/ ceiling / Rafter / Girder | Each | 122.0 | 122.0 | 30.0 | False | None | None | False | None | False | 3660.0 | 0 | 3002970 | 100184 | None | Item No.13.11 | Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired | Each | 315.0 | 315.0 | 16.0 | False | None | None | False | None | False | 5040.0 | 0 | 3002971 | 100184 | None | Item No. 5.18 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A SP | Each | 415.0 | 415.0 | 5.0 | False | None | None | False | None | False | 2075.0 | 0 | 3002972 | 100184 | None | Item no. 5.18.6 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63 A DP | Each | 1102.0 | 1102.0 | 3.0 | False | None | None | False | None | False | 3306.0 | 0 | 3002973 | 100184 | None | Item No. 5.18.7 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32A TPN | Each | 1717.0 | 1717.0 | 3.0 | False | None | None | False | None | False | 5151.0 | 0 | 3002974 | 100184 | None | Item No. 5.19-5.19.14 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.-12 Way TP & N | Each | 8735.0 | 8735.0 | 1.0 | False | None | None | False | None | False | 8735.0 | 0 | 3002975 | 100184 | None | Item no.5.2 | Supplying, fixing and wiring Residual current circuit breaker (RCCB)240/450V upto 300mA sensitivity on existing wood/ panel board. | Each | 5147.0 | 5147.0 | 1.0 | False | None | None | False | None | False | 5147.0 | 0 |
| 1710236117000 | 0 | None | None | Buildings | Providing the Electrical works to the Kitchen Block and Dining hall Ground Floor and First floor UG Cable I B at Nyamati Honnali Taluk. | 253104.5 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3002976 | 100185 | None | Item No. 32-32.11 | 1.1 kV, XLPE or Heat resistant PVC
insulated, PVC exutruted Inner Seath
Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip
thickness and resistivity as per IS-3975
50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm) | Km | 178973.0 | 178973.0 | 0.5 | False | None | None | False | None | False | 89486.5 | 0 | 3002977 | 100185 | None | 21.01 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff- 3x95 to 150 mm | Km | 61322.0 | 61322.0 | 0.5 | False | None | None | False | None | False | 30661.0 | 0 | 3002978 | 100185 | None | 51.01 | GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg | No | 743.0 | 743.0 | 4.0 | False | None | None | False | None | False | 2972.0 | 0 | 3002979 | 100185 | None | 51.02 | 2 Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each | No | 676.0 | 676.0 | 4.0 | False | None | None | False | None | False | 2704.0 | 0 | 3002980 | 100185 | None | Item No. 51.03 | Good Quality Salt for grounding purposes packed in 50 Kg gunny bag | Bag | 310.0 | 310.0 | 4.0 | False | None | None | False | None | False | 1240.0 | 0 | 3002981 | 100185 | None | Item No.51.04 | Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified | No | 2172.0 | 2172.0 | 4.0 | False | None | None | False | None | False | 8688.0 | 0 | 3002982 | 100185 | None | Item No.5.18-5.18.8 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.- 40A TPN | Each | 3044.0 | 3044.0 | 5.0 | False | None | None | False | None | False | 15220.0 | 0 | 3002983 | 100185 | None | Item No.5.18.9 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.-50-63 TPN | Each | 3088.0 | 3088.0 | 4.0 | False | None | None | False | None | False | 12352.0 | 0 | 3002984 | 100185 | None | 5.15 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.-100A 25 KA | Each | 6086.0 | 6086.0 | 1.0 | False | None | None | False | None | False | 6086.0 | 0 | 3002985 | 100185 | None | 5.42-5.42.1 | Fabricating supplying and mounting MS box made out .SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.- 14 SWG | Cum | 0.5 | 0.5 | 80000.0 | False | None | None | False | None | False | 40000.0 | 0 | 3002986 | 100185 | None | Item No. 5.11-5.11.5 | Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. (Open Execution)-250 A | Each | 19290.0 | 19290.0 | 1.0 | False | None | None | False | None | False | 19290.0 | 0 | 3002987 | 100185 | None | Item No. 5.27 | Supplying, fixing and wiring rotary selector switch suitable for Ammeter | Each | 200.0 | 200.0 | 1.0 | False | None | None | False | None | False | 200.0 | 0 | 3002988 | 100185 | None | Item No. 5.28 | Supplying, fixing and wiring rotary selector switch suitable for Voltmeter | Each | 160.0 | 160.0 | 1.0 | False | None | None | False | None | False | 160.0 | 0 | 3002989 | 100185 | None | Item No.5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. | Each | 515.0 | 515.0 | 3.0 | False | None | None | False | None | False | 1545.0 | 0 | 3002990 | 100185 | None | 5.4-5.41 | Supplying . A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete-250 A 4 x 30 x 10 mm Aluminium Strips | m | 3435.0 | 3435.0 | 5.5 | False | None | None | False | None | False | 18892.5 | 0 | 3002991 | 100185 | None | Item No. 5.41-5.41.3 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. Flat.with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.-75x75x6mm | m | 555.0 | 555.0 | 6.5 | False | None | None | False | None | False | 3607.5 | 0 |
| 1710236117000 | 0 | None | None | Buildings | Furniture | 1600893.2 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3002992 | 100186 | None | KSFIC DWD 33 | Teak wood 2 leg(side legs) dining table: Of size 6'x3'. Leg size 2.5x6"x6"=02 nos. Support patti-1.5'x4.5"x2"-06 nos. Top support 3'x4"x1.5'-01 no. & middle support 4.5'x3"x1.5"=01 n0. with 12mm glass for table top. Table shall be neatly finished and polished | Each | 39420.0 | 39420.0 | 4.0 | False | None | None | False | None | False | 157680.0 | 0 | 3002993 | 100186 | None | KSFIC DWD 042 | Teak wood dinning chair :seat with teakwood patti back with bend shape patti (Latest model) as per photo | Each | 11980.0 | 11980.0 | 16.0 | False | None | None | False | None | False | 191680.0 | 0 | 3002994 | 100186 | None | KSFIC DWD 093 | Conference table : (Plywood with laminate dtop ) of size width 2' height 2.5. Made out of 18mm plywood for top & front with both side laminate dand front side closed. Inner side shall be provided suitable vertical support of 36 mm plywood. Table shall be provided with footrest with suitable mm plywood. Table inner side shall be polish or paint (Rate per running ft) | Feet | 4840.0 | 4840.0 | 30.0 | False | None | None | False | None | False | 145200.0 | 0 | 3002995 | 100186 | None | KSFIC DWD 112 | High Back Cushion Chair : High back chair with seat and back high quality feather touch rexin of any colour, arms with SS Plated frame and cusioning, SS Base 5 caster wheel legs along with Syncro Mechanism. | Each | 17980.0 | 17980.0 | 10.0 | False | None | None | False | None | False | 179800.0 | 0 | 3002996 | 100186 | None | KSFIC DWD 104 | Providing and fixing storage unit : of 0.75m width made out pof 19mm thick commercial ply vertical support finished in approved 1.5mm laminated with 12mm thick ply packing internally finished with enamel paint of approved colour and shade shelves shall be formed out of 19mm ply finshed wih enamel paint of approved shade and colour 19mm thick shtters formed out 19mm thick ply finished with 1.5mm thick laminated of approved shade and colour et., complete the rate includes cost of all materials, labour charges, completee as per specification (Rate per Sq.Mtr) | Sqm | 19940.0 | 19940.0 | 16.28 | False | None | None | False | None | False | 324623.2 | 0 | 3002997 | 100186 | None | KSFIC.DWD 002 | Teak wood Damru sofa set : 1+3+1 with tepaoy and cushion, made out of teak wood front and back legs 3.5"x3.5", sofa front patti 5"x1.5" . Sofa support side bars 4"xx1.25" & 1.5"x1" repers. Sofa handle sixe 5"1.5". Sofa set shall be neatly finished and polished | Each | 96780.0 | 96780.0 | 4.0 | False | None | None | False | None | False | 387120.0 | 0 | 3002998 | 100186 | None | KSFIC.DWD 071 | Peacock Chair: (Standard company) Seat, and Back half cushion withh cloth or Rexin | Each | 4570.0 | 4570.0 | 47.0 | False | None | None | False | None | False | 214790.0 | 0 |
|
|
---|