createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1709201505454
version7
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd444000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose30-03-2024 17:30:00
tenderQueryClose22-03-2024 11:00:00
technicalBidOpen01-04-2024 11:00:00
publishedDate15-03-2024 10:21:08
publishedByPostTMC_CO_BRR
publishedByUserKPE12682 - V D SHANTHALA
bidValidityPeriod180
noOfCalls1
preBidMeetingDate26-03-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonNooruddin
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9986967861
tenderSupplierListNone
tenderSchedule
createdTs1709201505506
version11
createdDateNone
modifiedDateNone
tenderNumberDMA/2023-24/OW/WORK_INDENT15493
titleCONSTRUCTION OF SWM COMPONETS IN BIRURU SWM SITE BIRURU TMC CHIKKAMAGALURU DISTRICT
descriptionCONSTRUCTION OF SWM CIVIL STRUCTURES(PROCESSING SHED,SECURITY ROOM & WEIGH BRIDGE CONTROL STATION, LEACHATE COLLECTION TANK, PGF,EVAPORATION POND,SLF,WATER SUPPLY,ROAD AND DRAIN WORKS)
categoryWORKS
categoryTextWorks
ecv29577165.50
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location2285
locationNameDMA Town Municipal Council Birur
provisionalAmount29600000.0
groupOverheadTotal4511771.01
fileNumberTMC/BIR/SBM/01/2023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17092015060001NoneNoneOther WorksCONSTRUCTION OF SWM CIVIL STRUCTURES(PROCESSING SHED,SECURITY ROOM & WEIGH BRIDGE CONTROL STATION, LEACHATE COLLECTION TANK, PGF,EVAPORATION POND,SLF,WATER SUPPLY,ROAD AND DRAIN WORKS)25065394.49
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
286055792937Nonetmcbsbm1Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.(Vol-I,P.No:8,I.No: 1.12 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationCum97.8597.851470.0FalseNoneNoneFalseNoneFalse143839.50
286055892937Nonetmcbsbm2Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m(Vol-I,P.No:8,I.No: 1.14.1 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationCum105.06105.065403.43FalseNoneNoneFalseNoneFalse567684.35580
286055992937Nonetmcbsbm3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specificationsMix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates(Vol-I,P.No:15,I.No: 2.1.2 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationCum5833.925833.92231.21FalseNoneNoneFalseNoneFalse1348860.64320
286056092937Nonetmcbsbm4Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Vol-I,P.No:16,I.No: 2.4.3of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationCum6526.086526.0828.77FalseNoneNoneFalseNoneFalse187755.32160
286056192937Nonetmcbsbm5Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)(Vol-I,P.No:9,I.No: 5.4 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationCum6580.676580.6777.65FalseNoneNoneFalseNoneFalse510989.02550
286056292937Nonetmcbsbm6Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.(Vol-I,P.No:15,I.No: 2.2.3 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationCum7048.177048.1757.51FalseNoneNoneFalseNoneFalse405340.25670
286056392937Nonetmcbsbm7Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Vol-I,P.No:16,I.No: 2.3.2 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationCum10011.610011.621.36FalseNoneNoneFalseNoneFalse213847.7760
286056492937Nonetmcbsbm8Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Vol-I,P.No:16,I.No: 2.3.2 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationCum7008.127008.12233.38FalseNoneNoneFalseNoneFalse1635555.04560
286056592937Nonetmcbsbm9Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Vol-I,P.No:16,I.No: 2.5.2 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationCum11982.0911982.0935.47FalseNoneNoneFalseNoneFalse425004.73230
286056692937Nonetmcbsbm10Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(Vol-I,P.No:16,I.No: 2.5.2 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationCum11277.2611277.2624.78FalseNoneNoneFalseNoneFalse279450.50280
286056792937Nonetmcbsbm11Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specificationsM25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(Vol-I,P.No:16,I.No: 2.5.2 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationCum10572.4410572.448.06FalseNoneNoneFalseNoneFalse85213.86640
286056892937Nonetmcbsbm12Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specificationsM25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(Vol-I,P.No:16,I.No: 2.5.2 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationCum10220.0210220.020.98FalseNoneNoneFalseNoneFalse10015.61960
286056992937Nonetmcbsbm13Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Buildings(Vol-I,P.No:18,I.No: 2.11a of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationTonne92140.7192140.7122.6FalseNoneNoneFalseNoneFalse2082380.0460
286057092937Nonetmcbsbm14Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(Vol-II,P.No:17,I.No: 6.32 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationSqm1349.31349.3180.84FalseNoneNoneFalseNoneFalse244007.4120
286057192937Nonetmcbsbm15Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(Vol-II,P.No:17,I.No: 6.34 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationSqm1137.121137.1277.85FalseNoneNoneFalseNoneFalse88524.7920
286057292937Nonetmcbsbm16Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge(Vol-II,P.No:41,I.No: 8.3.1 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationSqm364.62364.62366.56FalseNoneNoneFalseNoneFalse133655.10720
286057392937Nonetmcbsbm17Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge(Vol-II,P.No:41,I.No: 8.1.1 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationSqm262.65262.65162.81FalseNoneNoneFalseNoneFalse42762.04650
286057492937Nonetmcbsbm18Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Vol-II,P.No:41,I.No: 8.2.1 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationSqm303.85303.8515.33FalseNoneNoneFalseNoneFalse4658.02050
286057592937Nonetmcbsbm19Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and in- cluding water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge (Vol-II,P.No:45,I.No: 8.25 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationSqm141.11141.11992.01FalseNoneNoneFalseNoneFalse139982.53110
286057692937Nonetmcbsbm20Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(Vol-II,P.No:46,I.No: 8.30 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationSqm179.22179.22152.36FalseNoneNoneFalseNoneFalse27305.95920
286057792937Nonetmcbsbm21Finishing with Epoxy paint (two coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Enginer-in-charge (Vol-II,P.No:47,I.No: 8.36.1 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationSqm181.28181.28378.4FalseNoneNoneFalseNoneFalse68596.3520
286057892937Nonetmcbsbm22Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge (Vol-II,P.No:82,I.No: 11.16.2 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationKgs151.41151.4121814.57FalseNoneNoneFalseNoneFalse3302944.04370
286057992937Nonetmcbsbm23Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge.0.63 mm thick with zinc coating not less than 275 g/sqm (Vol-II,P.No:21,I.No: 7.1.1 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationSqm905.37905.371730.0FalseNoneNoneFalseNoneFalse1566290.10
286058092937Nonetmcbsbm24Providing & fixing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete as per design drawings 0.63 mm thick with zinc coating not less than 275 g/sqm (Vol-II,P.No:21,I.No: 7.4.1 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationm658.17658.17100.0FalseNoneNoneFalseNoneFalse65817.00
286058192937Nonetmcbsbm25Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete Gutter (600 mm over all girth) (Vol-II,P.No:27,I.No: 7.39.6 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationm1106.221106.22150.0FalseNoneNoneFalseNoneFalse165933.00
286058292937Nonetmcbsbm26Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (Vol-I,P.No:15,I.No: 2.1.4 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationCum6403.516403.5110.8FalseNoneNoneFalseNoneFalse69157.9080
286058392937Nonetmcbsbm27Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (Vol-I,P.No:7,I.No: 1.9 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationCum273.98273.98486.78FalseNoneNoneFalseNoneFalse133367.98440
286058492937Nonetmcbsbm28Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.(Vol-II,P.No:65,I.No: 9.3.8 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationSqm1433.761433.7615.33FalseNoneNoneFalseNoneFalse21979.54080
286058592937Nonetmcbsbm29Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete.(Vol-II,P.No:60,I.No: 9.9 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationSqm1108.281108.282.4FalseNoneNoneFalseNoneFalse2659.8720
286058692937Nonetmcbsbm30Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm (Vol-II,P.No:60,I.No: 9.12.2 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationSqm1179.351179.3544.4FalseNoneNoneFalseNoneFalse52363.140
286058792937Nonetmcbsbm31Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.(Vol-II,P.No:100,I.No: 12.13.1 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationCum101779.45101779.450.26FalseNoneNoneFalseNoneFalse26462.6570
286058892937Nonetmcbsbm32Providing & fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top & bottom rails, covered with heat moulded PVC C channel of 5mm thick sheet & 30 x 50mm wide to form stiles & 5mm thick & 75mm wide PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the stiles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm Aluminium hinges.(Vol-II,P.No:104,I.No: 12.53 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationSqm1635.641635.643.15FalseNoneNoneFalseNoneFalse5152.2660
286058992937Nonetmcbsbm33Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.with one side prelam (Vol-II,P.No:104,I.No: 12.55.2 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationSqm2101.22101.23.78FalseNoneNoneFalseNoneFalse7942.5360
286059092937Nonetmcbsbm34Providing & fixing of 2-trackx 2panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermos Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware single point locking system with Crescent Locks. Wall thickness of frame sash shall be of 2 mm. Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&P shall not be made) (Vol-II,P.No:108,I.No: 12.84 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationSqm5173.695173.6910.8FalseNoneNoneFalseNoneFalse55875.8520
286059192937Nonetmcbsbm35Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (Vol-II,P.No:109,I.No: 12.85 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationSqm5890.575890.570.54FalseNoneNoneFalseNoneFalse3180.90780
286059292937Nonetmcbsbm36Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(Vol-II,P.No:47,I.No: 8.34.1 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationSqm54.5954.595.16FalseNoneNoneFalseNoneFalse281.68440
286059392937Nonetmcbsbm37Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(Vol-II,P.No:48,I.No: 8.40 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationSqm118.45118.455.16FalseNoneNoneFalseNoneFalse611.2020
286059492937Nonetmcbsbm38Providing Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement :3 coarse sand), finished with a floating coat of neat cement.18mm thick(Vol-II,P.No:59,I.No: 9.3.1 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationSqm496.46496.463.96FalseNoneNoneFalseNoneFalse1965.98160
286059592937Nonetmcbsbm39Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 450x300x150 mm (Vol-II,P.No:134,I.No:14.11.1 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationEach4026.274026.272.0FalseNoneNoneFalseNoneFalse8052.540
286059692937Nonetmcbsbm40Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid (Vol-II,P.No:131,I.No: 14.2.1 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationEach4983.144983.142.0FalseNoneNoneFalseNoneFalse9966.280
286059792937Nonetmcbsbm41Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931(Vol-II,P.No:119,I.No: 13.12 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationEach654.05654.054.0FalseNoneNoneFalseNoneFalse2616.20
286059892937Nonetmcbsbm42Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.(Vol-II,P.No:119,I.No: 13.15 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationEach746.75746.752.0FalseNoneNoneFalseNoneFalse1493.50
286059992937Nonetmcbsbm43Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber 100mm x 100mm size P type with Non Modular common burnt clay bricks of designation 3.5& water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: (Vol-II,P.No:123,I.No: 13.38 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationEach2607.962607.962.0FalseNoneNoneFalseNoneFalse5215.920
286060092937Nonetmcbsbm44Providing and fixing 100 mm sand cast Iron grating for gully trap.(Vol-II,P.No:136,I.No: 14.29 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationEach48.4148.412.0FalseNoneNoneFalseNoneFalse96.820
286060192937Nonetmcbsbm45Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.-15mm nominal OD pipes(Vol-II,P.No:122,I.No: 13.32.1 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationm318.27318.279.31FalseNoneNoneFalseNoneFalse2963.09370
286060292937Nonetmcbsbm46Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20mm nominal dia pipe (Vol-II,P.No:122,I.No: 13.32.2 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationm390.37390.3710.0FalseNoneNoneFalseNoneFalse3903.70
286060392937Nonetmcbsbm47Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.(Vol-II,P.No:136,I.No: 14.31 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationEach1256.61256.62.0FalseNoneNoneFalseNoneFalse2513.20
286060492937Nonetmcbsbm48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes of 150mm dia conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.(Vol-II,P.No:125,I.No: 13.49 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationEach585.04585.0430.0FalseNoneNoneFalseNoneFalse17551.20
286060592937Nonetmcbsbm49Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 75 mm diameter(Vol-II,P.No:125,I.No: 13.47 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationm202.91202.9121.0FalseNoneNoneFalseNoneFalse4261.110
286060692937Nonetmcbsbm50Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.(Vol-II,P.No:123,I.No: 13.34 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationLtr9.279.274000.0FalseNoneNoneFalseNoneFalse37080.00
286060792937Nonetmcbsbm51Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary b)25mm dia 2mm thick (Elec SR,P.No:2,I.No: 1.2.2 ) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationm78.078.040.0FalseNoneNoneFalseNoneFalse3120.00
286060892937Nonetmcbsbm52Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete. 12" x 12" x 3" (300 x 300 x 76 mm)(Elec SR,P.No:3,I.No: 1.6.1 ) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationEach120.0120.02.0FalseNoneNoneFalseNoneFalse240.00
286060992937Nonetmcbsbm53Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete.10" x 7" x 3" (254 x 178 x 76 mm) (Elec SR,P.No:3,I.No: 1.6.3 ) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationEach112.0112.02.0FalseNoneNoneFalseNoneFalse224.00
286061092937Nonetmcbsbm54Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete.8" x 6" x 3" (203 x 152 x 76 mm)(Elec SR,P.No:3,I.No: 1.6.4) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationEach86.086.02.0FalseNoneNoneFalseNoneFalse172.00
286061192937Nonetmcbsbm55Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 3C x 2.5 mm2 (Elec SR,P.No:6,I.No: 2.5.8 ) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationm113.0113.0300.0FalseNoneNoneFalseNoneFalse33900.00
286061292937Nonetmcbsbm56Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.10-12 Module(Elec SR,P.No:8,I.No: 3.5.6 ) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationNo344.0344.02.0FalseNoneNoneFalseNoneFalse688.00
286061392937Nonetmcbsbm57Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.8 Module (Elec SR,P.No:8,I.No: 3.5.5 ) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationNo284.0284.02.0FalseNoneNoneFalseNoneFalse568.00
286061492937Nonetmcbsbm58Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.6 Module (Elec SR,P.No:8,I.No: 3.5.4 ) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationNo234.0234.04.0FalseNoneNoneFalseNoneFalse936.00
286061592937Nonetmcbsbm59Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A One Way Switch (Elec SR,P.No:9,I.No: 3.6.1) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationNo102.0102.020.0FalseNoneNoneFalseNoneFalse2040.00
286061692937Nonetmcbsbm60Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A Three Way socket (Elec SR,P.No:9,I.No: 3.6.3 ) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationNo171.0171.04.0FalseNoneNoneFalseNoneFalse684.00
286061792937Nonetmcbsbm61Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 12936/16A Universal Socket (Elec SR,P.No:9,I.No: 3.6.10 ) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationNo236.0236.02.0FalseNoneNoneFalseNoneFalse472.00
286061892937Nonetmcbsbm62Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 129332A DP Switch (Elec SR,P.No:9,I.No: 3.6.9 of ) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationNo326.0326.01.0FalseNoneNoneFalseNoneFalse326.00
286061992937Nonetmcbsbm63Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.32 A (Elec SR,P.No:14,I.No: 5.7.2) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationNo241.0241.01.0FalseNoneNoneFalseNoneFalse241.00
286062092937Nonetmcbsbm64Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A DP (Elec SR,P.No:17,I.No: 5.18.4 ) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationNo739.0739.02.0FalseNoneNoneFalseNoneFalse1478.00
286062192937Nonetmcbsbm65Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.6 Way SP & N (Elec SR,P.No:18,I.No: 5.19.2 ) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationNo1186.01186.01.0FalseNoneNoneFalseNoneFalse1186.00
286062292937Nonetmcbsbm66Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 A three phase 4 wire whole current class-1 Accuracy Energy Meter. (Elec SR,P.No:19,I.No: 5.35) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationNo5705.05705.01.0FalseNoneNoneFalseNoneFalse5705.00
286062392937Nonetmcbsbm67Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. (Elec SR,P.No:30,I.No: 6.1) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationNo1492.01492.02.0FalseNoneNoneFalseNoneFalse2984.00
286062492937Nonetmcbsbm68Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200 mm) Regular model (Elec SR,P.No:30,I.No: 6.3.1) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationNo2984.02984.02.0FalseNoneNoneFalseNoneFalse5968.00
286062592937Nonetmcbsbm69Supply of round/square recess/surface mounted rolling type LED Down light with W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V 50/60Hz & Power factor greater tah0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 5-6W (Elec SR,P.No:44,I.No: 11.5.1) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationNo571.0571.013.0FalseNoneNoneFalseNoneFalse7423.00
286062692937Nonetmcbsbm70Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12W(Elec SR,P.No:44,I.No: 11.5.2) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationNo885.0885.08.0FalseNoneNoneFalseNoneFalse7080.00
286062792937Nonetmcbsbm71Supplying of recess mounting non integral type LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70 pc efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322 IEC 60598, LM 79 LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly with PF 0.95, power loss should 5% of lamp Wage., short circuit open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' 36 W (Elec SR,P.No:45,I.No: 11.6.3) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationNo4553.04553.02.0FalseNoneNoneFalseNoneFalse9106.00
286062892937Nonetmcbsbm72Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia (Elec SR,P.No:54,I.No: 12.56) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationNo3510.03510.01.0FalseNoneNoneFalseNoneFalse3510.00
286062992937Nonetmcbsbm73Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.(Elec SR,P.No:57,I.No: 13.14) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationNo492.0492.02.0FalseNoneNoneFalseNoneFalse984.00
286063092937Nonetmcbsbm74Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.(Elec SR,P.No:57,I.No: 13.10) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationNo171.0171.02.0FalseNoneNoneFalseNoneFalse342.00
286063192937Nonetmcbsbm751.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-397516 Sqmm, 2 Core, (9 GI Strips - 4 x 0.8 mm (Elec SR,P.No:13,I.No: 32.04) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationKm88418.088418.00.02FalseNoneNoneFalseNoneFalse1768.360
286063292937Nonetmcbsbm76Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed.In Ordinary Soil (Elec SR,P.No:63,I.No: 29.02) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationCum260.0260.04.5FalseNoneNoneFalseNoneFalse1170.00
286063392937Nonetmcbsbm77Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cm. Thickness including depositing of the surplus earth with a lead of 200 Mtr (Elec SR,P.No:63,I.No: 29.07) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationCum58.058.04.5FalseNoneNoneFalseNoneFalse261.00
286063492937Nonetmcbsbm78Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff2.5 to 25 Sqmm (Elec SR,P.No:52,I.No: 21.05) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationKm20886.020886.00.02FalseNoneNoneFalseNoneFalse417.720
286063592937Nonetmcbsbm79HDPE Liner Supplying ,providing and laying of 1.5mm HDPE liner at Landfill including cost of all material labour etc complete as shown on drawing and as per specification and or direction of engineer.(Approved rate) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationSqm450.0450.02639.0FalseNoneNoneFalseNoneFalse1187550.00
286063692937Nonetmcbsbm80Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge (Vol-II,P.No:175,I.No: 17.1 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationCum1032.061032.0647.94FalseNoneNoneFalseNoneFalse49476.95640
286063792937Nonetmcbsbm81Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.(Vol-II,P.No:175,I.No: 17.3 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationCum1227.761227.7629.93FalseNoneNoneFalseNoneFalse36746.85680
286063892937Nonetmcbsbm82Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer- in-charge.(Vol-II,P.No:175,I.No: 17.2 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationCum1221.581221.5852.26FalseNoneNoneFalseNoneFalse63839.77080
286063992937Nonetmcbsbm83Providing and laying Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications.Stone/Boulder (Vol-III,P.No:129,I.No: 14.4A of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationCum1969.361969.3624.22FalseNoneNoneFalseNoneFalse47697.89920
286064092937Nonetmcbsbm84Geosynthetic Clay Liner: Supply and installation of geosynthetic clay liner laying anchoring in trench, seaming,testing complete as given in general specification complete to form an impervious barrier.GCL must be anchored within anchor trench including excavation of trench and backfilling,compaction complete at bottom portion.Rate to include the necessary lap for joining,wastage and testing including benotomite powder at joints etc, complete measurements will be made as per finished surface area.GCL in the anchor trench will be taken in the measurement(Approved Rate) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationSqm400.0400.02439.0FalseNoneNoneFalseNoneFalse975600.00
286064192937Nonetmcbsbm85Geotextile Membrane : Supplying,providing and laying 280(class) GSM Geotextile membrane at landfill including cost of all material,labour etc ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationSqm170.0170.02439.0FalseNoneNoneFalseNoneFalse414630.00
286064292937Nonetmcbsbm86Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0 HDPE Grade PE80-PN6.0,140mm dia (Vol-V,P.No:95,I.No: 9.1.6 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationm774.56774.56120.0FalseNoneNoneFalseNoneFalse92947.20
286064392937Nonetmcbsbm87Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0 HDPE Grade PE80-PN6.0,110mm dia (Vol-V,P.No:122,I.No:9.1.4 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationm483.07483.0750.0FalseNoneNoneFalseNoneFalse24153.50
286064492937Nonetmcbsbm88Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.(Vol-V,P.No:7,I.No: 1.8 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationCum488.22488.22877.5FalseNoneNoneFalseNoneFalse428413.050
286064592937Nonetmcbsbm89Providing, laying, spreading and compacting graded stone aggregate mixed with cement to crushed stone treated base specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with Paver in sub base / base course on well prepared surface and compacting with vibratary roller to achieve the desired density. (laying using Mechanical paver) (Vol-III,P.No:27,I.No: 4.18 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationCum3335.143335.14858.0FalseNoneNoneFalseNoneFalse2861550.120
286064692937Nonetmcbsbm90Prime Coat over WMM/WBM (i) Providing and applying primer coat with SS1 grade Bitumen Emulsion on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70 kg/m 2 using mechanical means.(Vol-III,P.No:31,I.No: 5.1A(i) of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationCum42.2342.234290.0FalseNoneNoneFalseNoneFalse181166.70
286064792937Nonetmcbsbm91Tack coat on Granular surface treated with primer Providing and applying tack coat with RS1 Bituminous Emulsion using emulsion pressure distributor at the rate of 0.25 kg/m 2 on Granular Surface.(Vol-III,P.No:31,I.No: 5.4 (ii)of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationSqm14.4214.424290.0FalseNoneNoneFalseNoneFalse61861.80
286064892937Nonetmcbsbm92Bituminous macadam Grading - i for traffic 20 mSa Providing and laying Bituminous Macadam with 100 TPH capacity hot mix plant batch type using crushed aggregates of specified grading premixed with bituminous binder VG-30 @ 3.3% by weight of mix, transported to site, laid over a previously prepared surface with mechanical paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction (Vol-III,P.No:31,I.No: 5.6(i) of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationCum7599.347599.34214.5FalseNoneNoneFalseNoneFalse1630058.430
286064992937Nonetmcbsbm93Bituminous Concrete Grading i for traffic 20 mSa Providing and laying Bituminous Concrete with 100 TPH capacity hot mix plant batch type using crushed aggregates of specified grading, premixed with bituminous binder VG-30 @ 5.2 per cent of mix and filler, transporting the hot mix to work site, laying with mechanical paver finisher to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respects (Vol-III,P.No:36,I.No: 5.14B of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationCum10853.1110853.11107.25FalseNoneNoneFalseNoneFalse1163996.04750
286065092937Nonetmcbsbm94Maintenance of earth Shoulder (stripping excess soil) Stripping excess soil from the shoulder surface to achieve the approved level and compacting with plate compactor (Vol-III,P.No:91,I.No: 10.3 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationSqm40.1740.17936.0FalseNoneNoneFalseNoneFalse37599.120
286065192937Nonetmcbsbm95Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Vol-I,P.No:16,I.No: 2.4.2 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationCum8792.138792.13118.2FalseNoneNoneFalseNoneFalse1039229.7660
286065292937Nonetmcbsbm96Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. etc. complete.(Vol-V,P.No:140,I.No: 12.4 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationNo5446.645446.641.0FalseNoneNoneFalseNoneFalse5446.640
286065392937Nonetmcbsbm97Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 0 to 50 Mtrs (Vol-V,P.No:139,I.No: 12.1.1of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationm381.1381.150.0FalseNoneNoneFalseNoneFalse19055.00
286065492937Nonetmcbsbm98Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)Borewell depth of 50 to 100 Mtrs (Vol-V,P.No:139,I.No: 12.1.2of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationm477.92477.9250.0FalseNoneNoneFalseNoneFalse23896.00
286065592937Nonetmcbsbm99Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)Borewell depth of 100 to 150 Mtrs (Vol-V,P.No:139,I.No: 12.1.3of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationm507.79507.7950.0FalseNoneNoneFalseNoneFalse25389.50
286065692937Nonetmcbsbm100Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)Borewell depth of 150 to 200 Mtrs (Vol-V,P.No:139,I.No: 12.1.4of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationm589.16589.1650.0FalseNoneNoneFalseNoneFalse29458.00
286065792937Nonetmcbsbm101Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. (Vol-V,P.No:143,I.No: 12.32of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationm1990.991990.9920.0FalseNoneNoneFalseNoneFalse39819.80
286065892937Nonetmcbsbm102Providing and laying at site of work MS casing caps as per IS 1239 (part- II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge (Vol-V,P.No:143,I.No: 12.34of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationNo168.92168.921.0FalseNoneNoneFalseNoneFalse168.920
286065992937Nonetmcbsbm103Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. 5.00 HP - 90 LPM @ 110 m = 15 STG Outlet Dia - 2.00" (Vol-V,P.No:152,I.No: 13.13.6of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationNo33101.1133101.111.0FalseNoneNoneFalseNoneFalse33101.110
286066092937Nonetmcbsbm104Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete.3 to 6 HP pumps (Vol-V,P.No:155,I.No: 13.23.2of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationNo9836.59836.51.0FalseNoneNoneFalseNoneFalse9836.50
286066192937Nonetmcbsbm105Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694/1990 with ISI Mark and as per its latest amendments.1x3x4 Sqm (Vol-V,P.No:154,I.No: 13.22.3of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationm139.05139.05100.0FalseNoneNoneFalseNoneFalse13905.00
286066292937Nonetmcbsbm106Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPTCL authorities and erection, electrification and commissioning of the same at the location of respective pump sets.(Vol-V P.No:155,I.No: 13.25of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationKvar566.5566.51.0FalseNoneNoneFalseNoneFalse566.50
286066392937Nonetmcbsbm107Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box.(Vol-V,P.No:155,I.No: 13.26of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationNo1184.51184.51.0FalseNoneNoneFalseNoneFalse1184.50
286066492937Nonetmcbsbm108Supply and delivery of galvanized mild steel tubes of 6mtr standard length heavy duty (C Class) as per IS 1239 (Part-I) 1990 with latest amendments with ISI Mark (one end fitted with Heavy Duty collar and other end fitted with protective cover) 50 mm (Vol-V,P.No:155,I.No: 13.27of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationNo3141.53141.515.0FalseNoneNoneFalseNoneFalse47122.50
286066592937Nonetmcbsbm109Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 50 mm (Vol-V,P.No:154,I.No: 13.25.1of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationNo1287.51287.51.0FalseNoneNoneFalseNoneFalse1287.50
286066692937Nonetmcbsbm110Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work.(Vol-V,P.No:156,I.No: 13.32of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationJob6695.06695.01.0FalseNoneNoneFalseNoneFalse6695.00
286066792937Nonetmcbsbm111Labour charges for erection of outdoor type panel board and meter board units with all necessary materials and labour, tools and equipments including providing cement concrete foundation bed etc., complete as per specification, with testing of as per instructions of engineer incharge of work.(Vol-V,P.No:156,I.No: 13.34of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationJob1493.51493.51.0FalseNoneNoneFalseNoneFalse1493.50
286066892937Nonetmcbsbm112Labour charges for providing connection using insulated sheathed steel wire cable as per IS 1554/ 1988 with latest amendments from KPTCL pole to meter board unit, with all necessary materials ,tools and equipments,as per specificationswith testing of as per instructions of engineer incharge of work.3.5 x 10 sqmm (Vol-V,P.No:156,I.No: 13.35.3of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationm200.85200.8530.0FalseNoneNoneFalseNoneFalse6025.50
286066992937Nonetmcbsbm113Providing main connection from pole PVC insulated sheathed steel wire cable in new trench as per IS 1554/ 1988 with latest amendments with ISI mark from KPTCL pole to meter board unit. (Vol-V,P.No:156,I.No: 13.36 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationm139.05139.0530.0FalseNoneNoneFalseNoneFalse4171.50
286067092937Nonetmcbsbm114Providing and fixing suitable for 1.1 KV class UG cable filled with necessary bitumen/insulating compound complete with terminals, clamps,bolts,nuts and washers etc. with necessary materials and labour tools and equipments as per instructions of engineer incharge of work.3.5x10 Sqm (Vol-V,P.No:156,I.No: 13.38.2of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationNo463.5463.51.0FalseNoneNoneFalseNoneFalse463.50
286067192937Nonetmcbsbm115Earthing: Providing and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia.(Vol-V,P.No:157,I.No: 13.39 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationNo3862.53862.51.0FalseNoneNoneFalseNoneFalse3862.50
286067292937Nonetmcbsbm116Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. All kinds of soils. Depth upto 1.50 m (Vol-I,P.No:10,I.No: 1.17.1of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationCum269.86269.86162.0FalseNoneNoneFalseNoneFalse43717.320
286067392937Nonetmcbsbm117Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0HDPE Grade PE80-PN6.0, 75mm dia (Vol-V,P.No:95,I.No: 9.1.2 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationm252.35252.35250.0FalseNoneNoneFalseNoneFalse63087.50
286067492937Nonetmcbsbm118Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0 HDPE Grade PE80-PN6.0, 63mm dia (Vol-V,P.No:95,I.No: 9.1.1of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationm194.67194.67150.0FalseNoneNoneFalseNoneFalse29200.50
286067592937Nonetmcbsbm119Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications (Vol-I,P.No:7,I.No: 1.10 of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationCum164.8164.8162.0FalseNoneNoneFalseNoneFalse26697.60
286067692937Nonetmcbsbm120Providing and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of Ductile Iron (DI) conforming ti IS-1865 with the latest amendments and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 with the latest amendments only. The stem sealing should be with toroidal sealing rings (minimum 2 " O " rings). Body and bonnet should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. For PN-10: (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) etc. complete For sluice Valve of PN - 10.0 and 50mm (Vol-V,P.No:22,I.No: 2.23.1of KPWD CSR) ---- Including all lead,lift, loading and unloading charges, cost of fueals and consumables and as per rthe directions of the engineer incharge of the work, complete as per specificationNo5701.055701.053.0FalseNoneNoneFalseNoneFalse17103.150
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17092015060000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17092015060000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17092015060000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17092015660000NoneNoneELIGIBILITYThe tenderer should be a PWD registered Contractor - also Contractors should have Registration of GST, Employers Provident Fund and tenderer should submit Registration Certificate along with technical bid.None
17092015960000NoneNoneELIGIBILITYAs per Karnataka state Government order LD/300/LET/2006 Bangalore dated 01.01.2007 and Government letter no PW/134/BMS/2007 dated 27.07.2007, a sum amounting to 1% of the bill amount will be deducted towards constructions labor welfare fund and Contractors should follow strictly prevailing rules of labor act.None
17092016140000NoneNoneELIGIBILITYConditional tenders will not be accepted.None
17092016480000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Government orders. The item rates quoted shall include cost of royalty charges on construction materials & other taxes as per the rates provided in prevailing cost & conveyance of all materials, Curing, Watering, unloading with all leads & lifts labor, hire charges of machinery equipment etc., complete including all incidental charges. All the items shall be executed as directed by the Engineer in charge of the work.None
17092016820000NoneNoneELIGIBILITYThe bidder shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costs. The tender fee is non-refundable and The employer is not responsible for any delay in accessing E- procurement portal.None
17092017060000NoneNoneELIGIBILITYOnly Original documents to be scanned and uploaded, Approving Authority reserves the right verify the Original Documents before approval, 0riginal documents / Certificates for qualification shall be produced when called for during evaluation of tender.None
17092017400000NoneNoneELIGIBILITYTenderer shall obtain the Work done Certificate in the prescribed format from the Competent Authority not below the rank of Executive Engineer (District Level Officer) and scan the Original Certificate and attach the scanned file to the tender. The Original Certificate shall be produced at the time of opening of Technical Bids for physical verification, if sought.None
17092017690000NoneNoneELIGIBILITYAs per Government order FD 447 EXP-12 2022 dated 30/07/2022, 18% GST will be added to the Contract amount separately. And Increase in GST shall not be paid in the extended period of contract for which the contractor alone is responsible for delay as determined by the authority while granting the extension of time.None
17092017920000NoneNoneELIGIBILITYThe employer reserves the rights to reject one or all tenders without assigning any reason.None
17092018260000NoneNoneELIGIBILITYPERFORMANCE SECURITY - The successful tenderer shall furnish Performance Security Deposit (Achievement Guarantee) at 5% of the amount put to tender with in 20 days after approve of tender as per rule 25.5 of the tender and clause 44 of the agreement in the form of FDR/Bank Guarantee duly pledged in the name of CHIEF OFFICER, .TOWN MUNICIPAL BIRUR CHIKKAMAGALUR DISTRICT.None
17092018720000NoneNoneELIGIBILITYThe intending contractors are requested to note that they should abide by the detailed instructions and conditions contained in the Standard Bid document.None
17092019380000NoneNoneELIGIBILITYSimilar work done certificate issued from Government/Semi Government/Local Body onlyNone
17102218350000NoneNoneELIGIBILITYSimialr work certificate shall include the works shown in standard documentNone
17102219920000NoneNoneELIGIBILITYContractors has to upload the EPF Registration with latest Challan Copy. Contractors has to submit their labour EPF details with every Running BillNone
17102220950000NoneNoneELIGIBILITYAll safety precautions, warning signs, night illumination, reflectors, deployment of security guards has to be ensured so that no untoward incident happens on account of negligence or any project activity. Contractor should indemnify the client to that extent.None
17103948490000NoneNoneELIGIBILITYThe Contractor shall have visited the site and shall submit the Certificate for the same duly signed by Chief officerNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneSatisfactoriy completed as prime contractor at-least one such similar work of value not less than Rs. 148.00 LakhsPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work Cement Concrete 522 cum, Earthwork - 5502.34 cum, tmt Steal 18.08 Tonne, Plastering 441 Sqm,Structural steel work 17452 kg,,Geosynthetic Clay liner 1952 Sqm,Geotextile membrane 1952 Sqm, Roofing sheet -1384 Sqm, SSM-63.00 Cum, Block Work-207 Sqm etcPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Quantity Certificate
NoneNoneNoneNoneSatisfactorily completed as prime contractor, at least one Similar work such as SWM component works of value not Less than Rs. 148.00 LakhsPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneList of existing commitments and ongoing works signed by the officer not below the rank of Executive EngineerPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- past experience
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract Rs. 592.00 LakhsCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneshould have in the last five years (i.e. 2018-19 to 2022-2023) achieved in at least one financial year a minimum financial turnover (in all classes civil engineering works only) of Rs 592.00Lakhs. Approved by CA with balance sheet & UDIN No.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNonePWD class- 2 and above Registration Certificate (Valid License copy issued by competent authority.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneContractors has to upload the EPF Registration with JANUARY 2024 Challan CopyCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- EPF Registration
NoneNoneNoneNoneContractor has to upload GST Declaration Certificate in the prescribed format.OthersContractor has to upload GST Declaration Certificate in the prescribed format.
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- GST DECLARATION
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Company Registration CertificateTrueTechnical Bid
Reserved Category CertificateFalseTechnical Bid
Similar work done certificateTrueTechnical Bid
Line of creditTrueTechnical Bid
EPF and ESI registratonTrueTechnical Bid
If the contractor submits a tender for lower rates, he should submit a DD equal to the lower tendered amountTrueTechnical Bid
GST DECLARATION CERTIFICATETrueTechnical Bid
Contractors has to upload the EPF Registration with JANUARY 2024 Challan CopyTrueTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
Other WorksChikkmagaluruKaduruChikmagalurBIRURSWM site located at Hirayangala village Survey No 434 & 4351335775567
tenderAddress
createdTs1710402832000
version0
createdDateNone
modifiedDateNone
blockNumberTMC Birur
streetNone
cityBirur
stateKarnataka
pin577116
tenderRecallDTONone