1710473609000 | 0 | None | None | Other Works | Construction of compound, Interlocking and other infrastructure works to Indira canteen in Rammanahalli TP Limit | 3840950.58 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3082344 | 105688 | None | code01 | Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. (PWD Comman SR Vol-1, 2023-24, Item no. 1.17.1, Page No.10) | Cum | 269.86 | 269.86 | 154.02 | False | None | None | False | None | False | 41563.8372 | 0 | 3082345 | 105688 | None | code02 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates (PWD SR Vol-01, 2023-24, Item no. 2.1.2, Page No.15) | Cum | 5833.92 | 5833.92 | 35.38 | False | None | None | False | None | False | 206404.0896 | 0 | 3082346 | 105688 | None | code03 | Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (PWD SR Vol-02, 2023-24, Item no.5.2, Page No.9) | Cum | 6816.54 | 6816.54 | 46.44 | False | None | None | False | None | False | 316560.1176 | 0 | 3082347 | 105688 | None | code04 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (PWD SR Vol-02, 2023-24, Item no.5.4, Page No.9) | Cum | 6580.67 | 6580.67 | 23.22 | False | None | None | False | None | False | 152803.1574 | 0 | 3082348 | 105688 | None | code05 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge (PWD SR Vol-02, 2023-24, Item no.8.19.1, Page No.44) | Cum | 262.65 | 262.65 | 103.2 | False | None | None | False | None | False | 27105.48 | 0 | 3082349 | 105688 | None | code06 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings (PWD Vol-1 SR 2023-24, Item No. 2.11a, Page No. 18) | Tonne | 92140.71 | 92140.71 | 1.1908 | False | None | None | False | None | False | 109721.157468 | 0 | 3082350 | 105688 | None | code07 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Foundation, Sub structure of Cross drainages (PWD SR, Vol.1, 2023-24, Item no. 2.4.3, Page No.16) | Cum | 6842.88 | 6842.88 | 5.81 | False | None | None | False | None | False | 39757.1328 | 0 | 3082351 | 105688 | None | code08 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Cement Concrete Drain Walls (PWD SR, Vol.1, 2023-24, Item no. 2.4.3, Page No.16) | Cum | 8743.68 | 8743.68 | 20.9485 | False | None | None | False | None | False | 183166.98048 | 0 | 3082352 | 105688 | None | code09 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications. (PWD Vol-1 SR 2023-24, Item no. 1.10, Page No.7) | Cum | 164.8 | 164.8 | 56.28 | False | None | None | False | None | False | 9274.944 | 0 | 3082353 | 105688 | None | code10 | Removal of Unserviceable Soil with Disposal up to a suitable distance as directed by the Engineer in charge of work (PWD SR Vol 3, 2023-24, Item no. 3.1, Page No.17) | Cum | 87.55 | 87.55 | 97.74 | False | None | None | False | None | False | 8557.137 | 0 | 3082354 | 105688 | None | code11 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (PWD Vol-2 SR 2023-24, Item no. 11.25.2, Page No.84) | Kg | 140.08 | 140.08 | 6592.5 | False | None | None | False | None | False | 923477.4 | 0 | 3082355 | 105688 | None | code12 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (PWD Vol-2 SR 2023-24, Item no. 11.16.2, Page No.82) | Kg | 140.08 | 140.08 | 1054.62 | False | None | None | False | None | False | 147731.1696 | 0 | 3082356 | 105688 | None | code13 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR Vol-02, 2023-24, Item no. 8.33, Page No.47) | Sqm | 143.17 | 143.17 | 282.0 | False | None | None | False | None | False | 40373.94 | 0 | 3082357 | 105688 | None | code14 | Providing and laying 60mm thick factory made precast M -30 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Cycle Tracks & Pedestrian Footpaths of approved shape and colour, laid in required pattern and including over 30mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-incharge. (WMM/WBM Base to be paid separately if necessary as per relevant technical specification) (PWD SR Vol-03, 2023-24, Item no. 6.8.2, Page No.51) | Sqm | 1100.04 | 1100.04 | 782.0 | False | None | None | False | None | False | 860231.28 | 0 | 3082358 | 105688 | None | code15 | Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) (PWD SR Vol-03, 2023-24, Item no. 6.8.2, Page No.51) | m | 1100.04 | 1100.04 | 86.0 | False | None | None | False | None | False | 94603.44 | 0 | 3082359 | 105688 | None | code16 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR Vol-02, 2023-24, Item no. 8.33.1, Page No.46) | Sqm | 162.74 | 162.74 | 337.98 | False | None | None | False | None | False | 55002.8652 | 0 | 3082360 | 105688 | None | code17 | Procurement of Ingredients: Procuremen of farm yard manure/compost, sandandred-earth (ingredients) required forraising seedlings inclusive of transportation, breaking of clods, sieving and heaping eaching redient separately at nursery site Fine coarse Red-earth/soil (Ceiling rate) (PWD SR Vol-08, 2022-23, Item no. 1.2, Page No.1) | Cum | 555.35 | 555.35 | 30.96 | False | None | None | False | None | False | 17193.636 | 0 | 3082361 | 105688 | None | code18 | Procurement of quality lawn grass, Mexican Grass Turf (PWD SR Vol-08, 2022-23, Item no. 12.10 G(c), Page No.49) | Cum | 206.0 | 206.0 | 68.8 | False | None | None | False | None | False | 14172.8 | 0 | 3082362 | 105688 | None | code19 | Labour Charges: mixing Input s as per prescribed proportion and quantity and spreading, applying fertilizers, digging, levelling, and dibbling with lawn grass at a spacing of 5cmx5cm & as per the direction of the Officer in charge of the work., Mexican Grass Turf (PWD SR Vol-08, 2022-23, Item no. 12.10 H(c), Page No.50) | Cum | 602.55 | 602.55 | 68.8 | False | None | None | False | None | False | 41455.44 | 0 | 3082363 | 105688 | None | code20 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 600X850 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. (PWD SR Vol-02, 2023-24, Item No.13.55 Page No.127) | Each | 7623.03 | 7623.03 | 2.0 | False | None | None | False | None | False | 15246.06 | 0 | 3082364 | 105688 | None | code21 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testingand commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 32mm dia., 10 kg/sqcm & class 5. (PWD SR Vol-05, 2023-24, l no. 10.1.2, Page No.113) | m | 69.01 | 69.01 | 120.0 | False | None | None | False | None | False | 8281.2 | 0 | 3082365 | 105688 | None | code22 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: Pipes of SN4, 160mm dia. (PWD SR Vol-05, 2023-24, l no. 10.2.4, Page No.114) | m | 593.28 | 593.28 | 40.0 | False | None | None | False | None | False | 23731.2 | 0 | 3082366 | 105688 | None | code23 | Supply and delivery at site special moulded variety PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments.32mm dia PVC couplers, (PWD SR Vol-05, 2023-24, ltem no.10.8.2, Page No.116) | Each | 16.48 | 16.48 | 10.0 | False | None | None | False | None | False | 164.8 | 0 | 3082367 | 105688 | None | code24 | Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.32 mm dia PVC Elbows. (PWD SR Vol-05, 2023-24, ltem no. 10.9.2, Page No.117) | Each | 21.63 | 21.63 | 15.0 | False | None | None | False | None | False | 324.45 | 0 | 3082368 | 105688 | None | code25 | Supply and delivery at site special moulded variety PVC bend as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.32 mm dia PVC BEND. (PWD SR Vol-05, 2023-24, ltem no. 10.11.2, Page No.118) | Each | 37.08 | 37.08 | 6.0 | False | None | None | False | None | False | 222.48 | 0 | 3082369 | 105688 | None | code26 | Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately.(For 1000 litre capacity) (PWD SR Vol-02, 2023-24, Sl no. 13.34A, Page No.123) | l | 9.27 | 9.27 | 1000.0 | False | None | None | False | None | False | 9270.0 | 0 | 3082370 | 105688 | None | code27 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :32 mm nominal bore. (PWD SR Vol-02, 2023-24, ltem no.13.4.2, Page No.117) | Nos. | 615.94 | 615.94 | 2.0 | False | None | None | False | None | False | 1231.88 | 0 | 3082371 | 105688 | None | code28 | Providing and fixing brass stop cock of approved quality : 20 mm nominal bore. (PWD SR Vol-02, 2023-24, ltem no.13.3.2, Page No.117) | Nos. | 314.15 | 314.15 | 4.0 | False | None | None | False | None | False | 1256.6 | 0 | 3082372 | 105688 | None | code29 | Providing and fixing brass bib cock of approved quality.20 mm nominal bore. (PWD SR Vol-02, 2023-24, ltem no.13.2.2, Page No.117) | Nos. | 314.15 | 314.15 | 2.0 | False | None | None | False | None | False | 628.3 | 0 | 3082373 | 105688 | None | code30 | Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary, 19/20 mm dia 2 mm thick, (PWD Electrical CSR 2023-24, IN-1.2.1, PN-2) | Mtr | 67.98 | 67.98 | 20.0 | False | None | None | False | None | False | 1359.6 | 0 | 3082374 | 105688 | None | code31 | Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary, 25 mm dia 2 mm thick (PWD Electrical CSR 2023-24, IN-1.2.2, PN-2), | Mtr | 80.34 | 80.34 | 55.0 | False | None | None | False | None | False | 4418.7 | 0 | 3082375 | 105688 | None | code32 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19/20 mm dia 2 mm thick (PWD Electrical CSR 2023-24, IN-1.3.1, PN-2), | Mtr | 70.04 | 70.04 | 10.0 | False | None | None | False | None | False | 700.4 | 0 | 3082376 | 105688 | None | code33 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25 mm dia 2 mm thick (PWD Electrical CSR 2023-24, IN-1.3.2, PN-2) | Mtr | 81.37 | 81.37 | 20.0 | False | None | None | False | None | False | 1627.4 | 0 | 3082377 | 105688 | None | code34 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mSqm (Phase & Neutral) & 1x1.0 mSqm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PWD Electrical SR 2021-22, Short point upto 3m from tapping point to out let via switch box. (PWD Electrical CSR 2021-2022, IN-2.2.1, PN-5), Short point upto 3m from tapping point to out let via switch box. | Mtr | 277.07 | 277.07 | 2.0 | False | None | None | False | None | False | 554.14 | 0 | 3082378 | 105688 | None | code35 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mSqm (Phase & Neutral) & 1x1.0 mSqm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PWD Electrical SR 2021-22, Short point upto 3m from tapping point to out let via switch box. (PWD Electrical CSR 2023-24, IN-2.2.2, PN-5), Medium point above 3m upto 6m from tapping point to out let via switch box. | Point | 390.37 | 390.37 | 6.0 | False | None | None | False | None | False | 2342.22 | 0 | 3082379 | 105688 | None | code36 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mSqm (Phase & Neutral) & 1x1.0 mSqm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PWD Electrical SR 2021-22, Short point upto 3m from tapping point to out let via switch box. (PWD Electrical CSR 2023-24, IN-2.2.2, PN-5), Long point above 6m upto 10m from tapping point to out let via switch box | Point | 571.65 | 571.65 | 16.0 | False | None | None | False | None | False | 9146.4 | 0 | 3082380 | 105688 | None | code37 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694 confirming to latest amendments.PWD Electrical CSR 2023-24, IN-2.3.2, PN-5), 1.5 mSqm | Mtr | 26.78 | 26.78 | 20.0 | False | None | None | False | None | False | 535.6 | 0 | 3082381 | 105688 | None | code38 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694 confirming to latest amendments.PWD Electrical CSR 2023-24, IN-2.3.3, PN-5), 2.5 mSqm | Mtr | 43.26 | 43.26 | 20.0 | False | None | None | False | None | False | 865.2 | 0 | 3082382 | 105688 | None | code39 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694 confirming to latest amendments. (PWD Electrical CSR 2023-24, IN-2.3.4, PN-5), 4 mSqm | Mtr | 64.89 | 64.89 | 45.0 | False | None | None | False | None | False | 2920.05 | 0 | 3082383 | 105688 | None | code40 | Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654, (PWD Electrical CSR 2023-24, IN-3.1.2, PN-8), 6A 3/5 Way | Each | 151.41 | 151.41 | 4.0 | False | None | None | False | None | False | 605.64 | 0 | 3082384 | 105688 | None | code41 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (PWD Electrical CSR 2023-24, IN-6.3.3, PN-9), 6A Three Way socket. | Each | 176.13 | 176.13 | 14.0 | False | None | None | False | None | False | 2465.82 | 0 | 3082385 | 105688 | None | code42 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, (PWD Electrical CSR 2023-24, IN-3.4.3, PN-8), 6 Way | Each | 182.31 | 182.31 | 1.0 | False | None | None | False | None | False | 182.31 | 0 | 3082386 | 105688 | None | code43 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, (PWD Electrical CSR 2023-24, IN-3.4.6, PN-8), 16-18 Way | Each | 328.57 | 328.57 | 2.0 | False | None | None | False | None | False | 657.14 | 0 | 3082387 | 105688 | None | code44 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box, (PWD Electrical CSR 2023-24, IN-3.5.3, PN-8), 6 Module | Each | 180.25 | 180.25 | 1.0 | False | None | None | False | None | False | 180.25 | 0 | 3082388 | 105688 | None | code45 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box, (PWD Electrical CSR 2023-24, IN-3.5.7, PN-8), 16 Module | Each | 408.91 | 408.91 | 2.0 | False | None | None | False | None | False | 817.82 | 0 | 3082389 | 105688 | None | code46 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCTgreater than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminairegreater than IK08. Power Factorgreater than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection.Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED fficiencygreater than1301m/w, nominal CRIgreater than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned.Note : 3) LED street lights that is procured, shall comply to the specification as per DMA Order(No. 25775DMA 69 DEVT 2018-19 Dated : 03-01-2019 ).(PWD Electrical CSR 2023-24, IN-11.8.1, PN-46), LED Streetlight 25 W | Each | 2497.75 | 2497.75 | 1.0 | False | None | None | False | None | False | 2497.75 | 0 | 3082390 | 105688 | None | code47 | Supplying and Fixing........mm dia class A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/ tubular pole, using suitable clA, bolts, nuts and wiring using suitable capacity wires.(PWD Electrical CSR 2023-24, IN-13.2.1, PN-56), Using 25mm dia G.I.Pipe | Each | 1239.09 | 1239.09 | 1.0 | False | None | None | False | None | False | 1239.09 | 0 | 3082391 | 105688 | None | code48 | Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires. (PWD Electrical CSR 2023-24, IN-13.5, PN-56) | Each | 166.86 | 166.86 | 1.0 | False | None | None | False | None | False | 166.86 | 0 | 3082392 | 105688 | None | code49 | Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRIgreater than 80. Power Input: 220-240V@ 50/60Hz & Power factorgreater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 4'-20/22 W, (PWD Electrical CSR 2023-24, IN-11.3.2, PN-43) | Each | 710.7 | 710.7 | 8.0 | False | None | None | False | None | False | 5685.6 | 0 | 3082393 | 105688 | None | code50 | Supplying of recess mounting non integrated type LED down light...... W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clA, LED of Power/COB with CCT 6500 degree K, CRIgreater than 70%. efficacygreater than100 lumen per W, 120degree beam spread, lifegreater than 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PFgreater than 0.95, power loss shouldless than 5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 10-12W (PWD Electrical CSR 2023-24, IN-11.4.2, PN-44) | Each | 1307.07 | 1307.07 | 10.0 | False | None | None | False | None | False | 13070.7 | 0 | 3082394 | 105688 | None | code51 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling /rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. On wall/ ceiling / Rafter / Girders. (PWD Electrical CSR 2023-2024, IN-13.7.1, PN-56) | Each | 125.66 | 125.66 | 10.0 | False | None | None | False | None | False | 1256.6 | 0 | 3082395 | 105688 | None | code52 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. (PWD Electrical CSR 2023-24, IN-3.14.6, PN-10), 6A Lamp Holder | No | 73.13 | 73.13 | 6.0 | False | None | None | False | None | False | 438.78 | 0 | 3082396 | 105688 | None | code53 | Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. (PWD Electrical CSR 2023-24, IN-6.1, PN-30). | Each | 1536.76 | 1536.76 | 6.0 | False | None | None | False | None | False | 9220.56 | 0 | 3082397 | 105688 | None | code54 | Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.. (PWD Electrical CSR 2023-24, IN-13.13, PN-57) | Each | 728.21 | 728.21 | 6.0 | False | None | None | False | None | False | 4369.26 | 0 | 3082398 | 105688 | None | code55 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. (PWD Electrical CSR 2023-24, IN-5.18.4, PN-17).6-32 A DP | Each | 761.17 | 761.17 | 2.0 | False | None | None | False | None | False | 1522.34 | 0 | 3082399 | 105688 | None | code56 | Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. (PWD Electrical CSR 2023-24, IN-5.42.2, PN-20).16SWG. | Sq CM | 0.44 | 0.44 | 8000.0 | False | None | None | False | None | False | 3520.0 | 0 | 3082400 | 105688 | None | code57 | Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. (PWD Electrical CSR 2023-24, IN-5.40.1, PN-20).100 A 4 x 30 x 6 mm Aluminium Strips | Mtr | 2538.95 | 2538.95 | 1.0 | False | None | None | False | None | False | 2538.95 | 0 | 3082401 | 105688 | None | code58 | Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 20A single phase Class-1 Accuracy with Temper Proof Energy Meter (PWD Electrical CSR 2023-24, IN-5.30, PN-19) | Each | 1421.4 | 1421.4 | 1.0 | False | None | None | False | None | False | 1421.4 | 0 | 3082402 | 105688 | None | code59 | Digging of Pit for providing GI Pipe type Earthing, Hard Soil, (Bescom CSR 2023-24, IN-1.6.2, PN-43) | Per Pit | 3079.7 | 3079.7 | 1.0 | False | None | None | False | None | False | 3079.7 | 0 | 3082403 | 105688 | None | code60 | GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg, (Bescom CSR 2021-22, IN-54.01, PN-17(Part-III)) | Nos. | 765.29 | 765.29 | 1.0 | False | None | None | False | None | False | 765.29 | 0 | 3082404 | 105688 | None | code61 | Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each, (Bescom CSR 2023-24, IN-51.02, PN-22) | Nos. | 696.28 | 696.28 | 1.0 | False | None | None | False | None | False | 696.28 | 0 | 3082405 | 105688 | None | code62 | Good Quality Salt for grounding purposes packed in 50 Kg gunny bag, (Bescom CSR 2023-24, IN-51.03, PN-22) | Nos. | 319.3 | 319.3 | 1.0 | False | None | None | False | None | False | 319.3 | 0 | 3082406 | 105688 | None | code63 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975, (Bescom CSR 2023-24, IN-32.03, PN-13), 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm) | Km | 121544.12 | 121544.12 | 0.06 | False | None | None | False | None | False | 7292.6472 | 0 | 3082407 | 105688 | None | code64 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable, (Bescom CSR 2023-24, IN-21.05, PN-52), 2.5 to 25 Sqmm | Km | 21512.58 | 21512.58 | 0.06 | False | None | None | False | None | False | 1290.7548 | 0 | 3082408 | 105688 | None | code65 | Aluminium End Terminal (Lug), 25 Sqmm (Bescom CSR 2023-24, IN-60.03, PN-27) | Each | 3.09 | 3.09 | 8.0 | False | None | None | False | None | False | 24.72 | 0 | 3082409 | 105688 | None | code66 | GI Pipe B - Class as per IS-1239, (Bescom CSR 2023-24, IN-49.04, PN-16(Part-III)), GI Pipe - 40 mm Dia | Mtr | 303.85 | 303.85 | 4.0 | False | None | None | False | None | False | 1215.4 | 0 | 3082410 | 105688 | None | code67 | Epoxy Terminating Kit (Pothead) suitable for 1.1 kV, LTUG Cable, (Bescom CSR 2021-22, IN-35.01, PN-15), Up to 4C x 50 Sqmm | Set | 333.72 | 333.72 | 1.0 | False | None | None | False | None | False | 333.72 | 0 | 3082411 | 105688 | None | code68 | Supply, delivery, erection and commissioning at site lighting distribution board suitable for monoblock centrifugal pump confirming with ISI mark and its latest amendments. (PWD SR Vol-05, 2021-22, Sl No.50, CODE:P480A, Page No.165) | Set | 4635.0 | 4635.0 | 1.0 | False | None | None | False | None | False | 4635.0 | 0 | 3082412 | 105688 | None | code69 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. (I.No. 1.8 P.No. 7of COMMON SCHEDULE OF RATES 2023-24) Vol-I | Cum | 488.22 | 488.22 | 810.0 | False | None | None | False | None | False | 395458.2 | 0 |
|