3076753 | 105245 | None | Vol (II) 6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement: 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work | Cum | 8367.45 | 8367.45 | 37.58 | False | None | None | False | None | False | 314448.771 | 0 |
3076754 | 105245 | None | Vol (II) 11.30 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 8689.8 | 8689.8 | 5.88 | False | None | None | False | None | False | 51096.024 | 0 |
3076755 | 105245 | None | Vol (II) 11.34B | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. | Kg | 192.15 | 192.15 | 181.44 | False | None | None | False | None | False | 34863.696 | 0 |
3076756 | 105245 | None | Vol (ll) 8.1.2 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement:6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 253.05 | 253.05 | 127.85 | False | None | None | False | None | False | 32352.4425 | 0 |
3076757 | 105245 | None | Vol (II) 8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 309.75 | 309.75 | 140.58 | False | None | None | False | None | False | 43544.655 | 0 |
3076758 | 105245 | None | Vol (II) 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge | Cum | 105.0 | 105.0 | 272.12 | False | None | None | False | None | False | 28572.6 | 0 |
3076759 | 105245 | None | Vol (ll) 8.8 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:6(1 cement :6coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 389.55 | 389.55 | 294.23 | False | None | None | False | None | False | 114617.2965 | 0 |
3076760 | 105245 | None | Vol (I) 2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6288.45 | 6288.45 | 9.59 | False | None | None | False | None | False | 60306.2355 | 0 |
3076761 | 105245 | None | Vol (II) 9.17.2 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08% and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. | Sqm | 1233.75 | 1233.75 | 141.63 | False | None | None | False | None | False | 174736.0125 | 0 |
3076762 | 105245 | None | Vol (II)12.88 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having a overall size of 60mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm X 58mm with GI reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24mm. Windows shall be provided with 5mm plain float glass, standard hardware & single point locking system with touch lock. Wall thickness of frame & sash shall be of 2-2.5 mm. Maximum possible size -1819mm x 1819mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made | Sqm | 6411.0 | 6411.0 | 8.64 | False | None | None | False | None | False | 55391.04 | 0 |
3076763 | 105245 | None | Vol (II) 8.25 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and in- cluding water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 143.85 | 143.85 | 272.12 | False | None | None | False | None | False | 39144.462 | 0 |
3076764 | 105245 | None | Vol (II) 8.30 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 182.7 | 182.7 | 294.23 | False | None | None | False | None | False | 53755.821 | 0 |
3076765 | 105245 | None | Vol (ll) 8.33.2 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.. | Sqm | 144.9 | 144.9 | 29.04 | False | None | None | False | None | False | 4207.896 | 0 |
3076766 | 105245 | None | Vol (ll) 11.28 | roviding and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 593.25 | 593.25 | 38.88 | False | None | None | False | None | False | 23065.56 | 0 |
3076767 | 105245 | None | Vol (ELECTRICAL) 1.2.1 | Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2 mm thick | Mtr | 64.05 | 64.05 | 100.0 | False | None | None | False | None | False | 6405.0 | 0 |
3076768 | 105245 | None | Vol (ELECTRICAL) 1.3.1 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.19/20 mm dia 2 mm thick | Mtr | 78.75 | 78.75 | 50.0 | False | None | None | False | None | False | 3937.5 | 0 |
3076769 | 105245 | None | Vol (ELECTRICAL) 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010,2.5 mm | Mtr | 42.0 | 42.0 | 200.0 | False | None | None | False | None | False | 8400.0 | 0 |
3076770 | 105245 | None | Vol (ELECTRICAL) 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010,4.00 mm | Mtr | 61.95 | 61.95 | 50.0 | False | None | None | False | None | False | 3097.5 | 0 |
3076771 | 105245 | None | Elect 3.4.2 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 4-5 way | No | 144.9 | 144.9 | 3.0 | False | None | None | False | None | False | 434.7 | 0 |
3076772 | 105245 | None | Elect 3.5.2 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall .4 Module | No | 183.75 | 183.75 | 3.0 | False | None | None | False | None | False | 551.25 | 0 |
3076773 | 105245 | None | Elect 3.6.1 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way | No | 92.4 | 92.4 | 12.0 | False | None | None | False | None | False | 1108.8 | 0 |
3076774 | 105245 | None | Elect 3.6.3 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket | No | 170.1 | 170.1 | 2.0 | False | None | None | False | None | False | 340.2 | 0 |
3076775 | 105245 | None | Elect 3.6.4 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Regulator | No | 328.65 | 328.65 | 4.0 | False | None | None | False | None | False | 1314.6 | 0 |
3076776 | 105245 | None | Elect 5.17.1 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32Amps SP | No | 549.15 | 549.15 | 2.0 | False | None | None | False | None | False | 1098.3 | 0 |
3076777 | 105245 | None | Elect 5.17.8 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40Amps SP | No | 2512.65 | 2512.65 | 1.0 | False | None | None | False | None | False | 2512.65 | 0 |
3076778 | 105245 | None | Elect 5.41.2 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint 50 x 50 x 6 mm | No | 373.8 | 373.8 | 8.0 | False | None | None | False | None | False | 2990.4 | 0 |
3076779 | 105245 | None | Elect 5.42.2 | Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.16 SWG | No | 0.4 | 0.4 | 8500.0 | False | None | None | False | None | False | 3400.0 | 0 |
3076780 | 105245 | None | Elect 6.1 | Earthing: Supplying, fixing, wiring earth electrode for grounding conduits, IC cutouts and other equipments on the meter board using 40mm dia 2.90 thick GI pipe 2.5mtrs long burried in a pit. The pit should be filled with equal proporation of salt and charcoal 150mm around the pipe to the complete depth. The connection from the pipe to the conduits etc., is to be established through GI wire of size as per ISI specification 7.3.3 of IS 732 using 12mm dia bolts, nuts, washers, and check nuts etc., the pipe shall have 16 nos of through holes of 12mm dia. etc., complete. | No | 3149.69 | 3149.69 | 1.0 | False | None | None | False | None | False | 3149.69 | 0 |
3076781 | 105245 | None | Elect 6.6.2 | Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc.. complete , In ordinary soil | Rmtr | 107.1 | 107.1 | 8.0 | False | None | None | False | None | False | 856.8 | 0 |
3076782 | 105245 | None | Elect 6.4.4 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975, 2 core 10 sqmm | Rmtr | 157.5 | 157.5 | 15.0 | False | None | None | False | None | False | 2362.5 | 0 |
3076783 | 105245 | None | Elect 6.5.1 | Labour charges for laying of 1.1 KV class UG cable in existing trench Gl pipe / stoneware pipe / on wall / on pole as required. 6 sqmm to 16 sqmm | Rmtr | 12.47 | 12.47 | 8.0 | False | None | None | False | None | False | 99.76 | 0 |
3076784 | 105245 | None | Elect 7.3.1 | Supplying capacitor type ceiling fan complete with down rod blades, snackles, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply confirming to IS-374-1979 and with double ball bearing system. 48" sweep (1200mm) regular model | No | 3096.45 | 3096.45 | 4.0 | False | None | None | False | None | False | 12385.8 | 0 |
3076785 | 105245 | None | Elect 14.9 | Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size | No | 295.05 | 295.05 | 4.0 | False | None | None | False | None | False | 1180.2 | 0 |
3076786 | 105245 | None | Elect 12.3.2 | Supplying of......feet - PVC Batten with integrated LED tube...... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical | No | 777.0 | 777.0 | 12.0 | False | None | None | False | None | False | 9324.0 | 0 |
3076787 | 105245 | None | Elect 14.7.1 | Fixing all types and all capacities flourescent/false wall/ceiling/rafters/girders using 23/0.0076" twin twisted PVC insulated wires, required nos. of round blcks and clamps (if required) on wall/ceiling/rafters/girders. wall/ceiling ceiling/spot light/CFL light/CFL fittings indoor | Mtr | 124.95 | 124.95 | 12.0 | False | None | None | False | None | False | 1499.4 | 0 |
3076788 | 105245 | None | M.R | Name Board | No | 2500.0 | 2500.0 | 1.0 | False | None | None | False | None | False | 2500.0 | 0 |