3007038 | 100328 | None | 001 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer In area of thorny jungle Vol-1 (pg no 9, I No 2.5 /ii/b) | 100 Sqm | 508.2 | 508.2 | 13.3 | False | None | None | False | None | False | 6759.06 | 0 |
3007039 | 100328 | None | 002 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth Vol-1 (pg no 8, I No 1.12) | Cum | 99.75 | 99.75 | 338.51 | False | None | None | False | None | False | 33766.3725 | 0 |
3007040 | 100328 | None | 003 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3m Vol-1 (pg no 8, I No 1.14.1) a) in all types of soils 90% of qty | Cum | 107.1 | 107.1 | 404.8649 | False | None | None | False | None | False | 43361.03079 | 0 |
3007041 | 100328 | None | 004 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work ordinary rock/Soft rock / with out blasting upto 1.5m depth Vol-1 (pg no 8, I No 1.15.1) b) Soft rock /ordinary rock(with out blasting) 10% of qty | Cum | 381.15 | 381.15 | 44.985 | False | None | None | False | None | False | 17146.03275 | 0 |
3007042 | 100328 | None | 005 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. Vol-2 (pg no 5, I No 4.1) | Sqm | 123.9 | 123.9 | 508.55 | False | None | None | False | None | False | 63009.345 | 0 |
3007043 | 100328 | None | 006 | Providing and laying in position Cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates Vol-1 (pg no 15, I No 2.1.3) | Cum | 6288.45 | 6288.45 | 82.145 | False | None | None | False | None | False | 516564.72525 | 0 |
3007044 | 100328 | None | 007 | Providing and laying in position Cement concrete for all Foundation works. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including Additional for formwork, Centering & Scaffolding for Sl No 1 a: Foundation upto plinth Isolated As per Addendum-I in Volume-1 of page No.-111 (@8% of Finished Rate) Vol-1 (pg no 15, I No 2.2.3) | Cum | 7185.02 | 7185.02 | 55.29 | False | None | None | False | None | False | 397259.7558 | 0 |
3007045 | 100328 | None | 008 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including Additional for formwork, Centering & Scaffolding for Sl No 9: RCC Columns As per Addendum-I in Volume-1 of page No.-111 (@70% of Finished Rate) Vol-1 (pg no 16, I No 2.4.3) | Cum | 11309.76 | 11309.76 | 8.54 | False | None | None | False | None | False | 96585.3504 | 0 |
3007046 | 100328 | None | 009 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including Additional for formwork, Centering & Scaffolding for Sl No 11: Earth retaining structures As per Addendum-I in Volume-1 of page No.-112 (@10% of Finished Rate) Vol-1 (pg no 16, I No 2.4.3) | Cum | 7318.08 | 7318.08 | 21.45 | False | None | None | False | None | False | 156972.816 | 0 |
3007047 | 100328 | None | 010 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. Vol-1 (pg no 7, I No 1.9) | Cum | 279.3 | 279.3 | 449.8499 | False | None | None | False | None | False | 125643.07707 | 0 |
3007048 | 100328 | None | 011 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. Vol-1 (pg no 7, I No 1.11) | Cum | 454.65 | 454.65 | 341.68 | False | None | None | False | None | False | 155344.812 | 0 |
3007049 | 100328 | None | 012 | Providing and laying in position Cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. including Additional for formwork, Centering & Scaffolding for Sl No 9 : RCC Columns As per Addendum-I in Volume-1 of page No.-111 (@70% of Finished Rate) Ground Floor Vol-1 (pg no 16, I No 2.5.2) | Cum | 12214.75 | 12214.75 | 14.5699 | False | None | None | False | None | False | 177967.686025 | 0 |
3007050 | 100328 | None | 013 | Providing and laying in position Cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. including Additional for formwork, Centering & Scaffolding for Sl No 1.a Plinth beam of buildings As per Addendum-I in Volume-1 of page No.-111 (@50% of Finished Rate) Ground Floor Vol-1 (pg no 16, I No 2.5.2) | Cum | 10777.73 | 10777.73 | 39.1699 | False | None | None | False | None | False | 422162.606327 | 0 |
3007051 | 100328 | None | 014 | Providing and laying in position Cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. including Additional for formwork, Centering & Scaffolding for Sl No 14 : beam & lintels of buildings As per Addendum-I in Volume-1 of page No.-112 (@60% of Finished Rate) Ground Floor Vol-1 (pg no 16, I No 2.5.2) | Cum | 11496.24 | 11496.24 | 44.54 | False | None | None | False | None | False | 512042.5296 | 0 |
3007052 | 100328 | None | 015 | Providing and laying in position Cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. including Additional for formwork, Centering & Scaffolding for Sl No 19 : Chejjas, Canopy & Other Architectural projections of minor sections As per Addendum-I in Volume-1 of page No.-112 (@45% of Finished Rate)Ground Floor Vol-1 (pg no 16, I No 2.5.2) | Cum | 10418.47 | 10418.47 | 3.12 | False | None | None | False | None | False | 32505.6264 | 0 |
3007053 | 100328 | None | 016 | Providing and laying in position Cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. including Additional for formwork, Centering & Scaffolding for Sl No 20 : Curved RCC Roof slab, Domes & Sloped Roofs As per Addendum-I in Volume-1 of page No.-112 (@70% of Finished Rate) Ground Floor Vol-1 (pg no 16, I No 2.5.2) | Cum | 12214.75 | 12214.75 | 134.81 | False | None | None | False | None | False | 1646670.4475 | 0 |
3007054 | 100328 | None | 017 | Providing and laying in position Cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. including Additional for formwork, Centering & Scaffolding for Sl No 16 : Staircase and other similiar structure As per Addendum-I in Volume-1 of page No.-112 (@50% of Finished Rate) Ground Floor Vol-1 (pg no 16, I No 2.5.2) | Cum | 13029.07 | 13029.07 | 23.16 | False | None | None | False | None | False | 301753.2612 | 0 |
3007055 | 100328 | None | 018 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification a. Buildings Vol-1 (pg no 18, I No 2.11(a)) | t | 93929.85 | 93929.85 | 41.83 | False | None | None | False | None | False | 3929085.6255 | 0 |
3007056 | 100328 | None | 019 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Vol-2 (pg no 14, I No 6.8) | Cum | 8367.45 | 8367.45 | 188.6899 | False | None | None | False | None | False | 1578853.303755 | 0 |
3007057 | 100328 | None | 020 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Vol-2 (pg no 14, I No 6.8) First Floor | Cum | 8451.12 | 8451.12 | 23.48 | False | None | None | False | None | False | 198432.2976 | 0 |
3007058 | 100328 | None | 021 | Providing Half Brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Vol-2 (pg no 14, I No 6.15) | Sqm | 1084.65 | 1084.65 | 11.83 | False | None | None | False | None | False | 12831.4095 | 0 |
3007059 | 100328 | None | 022 | Providing and laying in position Cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. y) Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates Vol-1 (pg no 16, I No 2.4.1) | Cum | 6724.2 | 6724.2 | 6.4799 | False | None | None | False | None | False | 43572.14358 | 0 |
3007060 | 100328 | None | 023 | Providing and laying in position Cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. y) Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates Vol-1 (pg no 16, I No 2.4.1) First Floor | Cum | 6791.44 | 6791.44 | 2.3 | False | None | None | False | None | False | 15620.312 | 0 |
3007061 | 100328 | None | 024 | Providing 12 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Vol-2 (pg no 41, I No 8.1.1) | Sqm | 267.75 | 267.75 | 1525.47 | False | None | None | False | None | False | 408444.5925 | 0 |
3007062 | 100328 | None | 025 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. Vol-2 (pg no 42, I No 8.8) | Sqm | 389.55 | 389.55 | 673.3499 | False | None | None | False | None | False | 262303.453545 | 0 |
3007063 | 100328 | None | 026 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. Vol-2 (pg no 42, I No 8.8) First Floor | Sqm | 393.44 | 393.44 | 679.88 | False | None | None | False | None | False | 267491.9872 | 0 |
3007064 | 100328 | None | 027 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineerin-Charge. Vol-2 (pg no 43, I No 8.12) | Kg | 67.2 | 67.2 | 101.0025 | False | None | None | False | None | False | 6787.368 | 0 |
3007065 | 100328 | None | 028 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineerin-Charge. Vol-2 (pg no 43, I No 8.12) First Floor | Kg | 67.87 | 67.87 | 101.982 | False | None | None | False | None | False | 6921.51834 | 0 |
3007066 | 100328 | None | 029 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth. Vol-2 (pg no 54, I No 8.80) | m | 69.3 | 69.3 | 164.0 | False | None | None | False | None | False | 11365.2 | 0 |
3007067 | 100328 | None | 030 | Providing and fixing plaster mesh 150mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services,junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications(length of mesh only be measured for payment) Vol-2 (pg no 43, I No 8.16.2) | m | 39.9 | 39.9 | 779.2 | False | None | None | False | None | False | 31090.08 | 0 |
3007068 | 100328 | None | 031 | Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixing chicken mesh for drop chajja, facia, backing to cup boards including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specifications. Specification No. KBS padadi works for arches as per design & drawing Vol-2 (sl no 8, I No 8.83) | Sqm | 1299.9 | 1299.9 | 7.4 | False | None | None | False | None | False | 9619.26 | 0 |
3007069 | 100328 | None | 032 | Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.. Size of Tile 600x1200 mm Vol-2 (pg no 60, I No 9.12.5) | Sqm | 1379.7 | 1379.7 | 91.13 | False | None | None | False | None | False | 125732.061 | 0 |
3007070 | 100328 | None | 033 | Providing and laying Cement concrete flooring 40 mm thick with 20 mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete. Vol-2 (pg no 59, I No 9.1) | Sqm | 473.55 | 473.55 | 98.86 | False | None | None | False | None | False | 46815.153 | 0 |
3007071 | 100328 | None | 034 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. Vol-2 (pg no 60, I No 9.11) | Sqm | 933.45 | 933.45 | 30.8 | False | None | None | False | None | False | 28750.26 | 0 |
3007072 | 100328 | None | 035 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. Vol-2 (pg no 65, I No 9.39) | Sqm | 1521.45 | 1521.45 | 89.77 | False | None | None | False | None | False | 136580.5665 | 0 |
3007073 | 100328 | None | 036 | Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. Vol-2 (pg no 64, I No 9.36) | Sqm | 1732.5 | 1732.5 | 3.48 | False | None | None | False | None | False | 6029.1 | 0 |
3007074 | 100328 | None | 037 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slabover 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Vol-2 (pg no 63, I No 9.24) | Sqm | 2994.6 | 2994.6 | 393.59 | False | None | None | False | None | False | 1178644.614 | 0 |
3007075 | 100328 | None | 038 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge Vol-2 (pg no 69, I No 10.2) | m | 344.4 | 344.4 | 46.95 | False | None | None | False | None | False | 16169.58 | 0 |
3007076 | 100328 | None | 039 | Providing and fixing of clay tiles for cladding tiles of size 230x75x10mm thick on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) & jointed with Adhesive/cement slurry over rough plaster surface excluding cost of rough plastered surface and the surface is painted with red apex paint and black apex paint into the groves. The work includes cost of all materials, labour charges for all items of work, usage charges for equipment, etc., complete as per specification. Vol-2 (pg no 72, I No 10.20) | Sqm | 1997.1 | 1997.1 | 289.2999 | False | None | None | False | None | False | 577760.83029 | 0 |
3007077 | 100328 | None | 040 | Providing and fixing of clay tiles for cladding tiles of size 230x75x10mm thick on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) & jointed with Adhesive/cement slurry over rough plaster surface excluding cost of rough plastered surface and the surface is painted with red apex paint and black apex paint into the groves. The work includes cost of all materials, labour charges for all items of work, usage charges for equipment, etc., complete as per specification. Vol-2 (pg no 72, I No 10.20) First Floor | Sqm | 2017.07 | 2017.07 | 66.67 | False | None | None | False | None | False | 134478.0569 | 0 |
3007078 | 100328 | None | 041 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. Vol-2 (pg no 99, I No 12.11) | Cum | 144977.7 | 144977.7 | 1.11 | False | None | None | False | None | False | 160925.247 | 0 |
3007079 | 100328 | None | 042 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. Vol-2 (pg no 104, I No 12.51) | Nos | 1066.8 | 1066.8 | 10.0 | False | None | None | False | None | False | 10668.0 | 0 |
3007080 | 100328 | None | 043 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick one side teak and one side commercial Vol-2 (pg no 105, I No 12.57.5) | Sqm | 4091.85 | 4091.85 | 27.36 | False | None | None | False | None | False | 111953.016 | 0 |
3007081 | 100328 | None | 044 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62x100mm Vol-2 (pg no 111, I No 12.93.1) | m | 737.1 | 737.1 | 17.1 | False | None | None | False | None | False | 12604.41 | 0 |
3007082 | 100328 | None | 045 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges. (Cost of Fixtures to be paid separately) 30mm thickness Vol-2 (pg no 111, I No 12.94.1) | Sqm | 3659.25 | 3659.25 | 4.725 | False | None | None | False | None | False | 17289.95625 | 0 |
3007083 | 100328 | None | 046 | Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Vol-2 (pg no 111, I No 12.92) | Sqm | 6557.25 | 6557.25 | 13.92 | False | None | None | False | None | False | 91276.92 | 0 |
3007084 | 100328 | None | 047 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having a overall size of 60mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm X 58mm with GI reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2-2.5 mm. Maximum possible size 1819mm x 1819mm (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) Vol-2 (pg no 110, I No 12.88) | Sqm | 5659.5 | 5659.5 | 30.0 | False | None | None | False | None | False | 169785.0 | 0 |
3007085 | 100328 | None | 048 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size -1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Vol-2 (pg no 109, I No 12.85) | Sqm | 6004.95 | 6004.95 | 10.53 | False | None | None | False | None | False | 63232.1235 | 0 |
3007086 | 100328 | None | 049 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. Vol-2 (pg no 86, I No 11.34B) | Kg | 192.15 | 192.15 | 983.13 | False | None | None | False | None | False | 188908.4295 | 0 |
3007087 | 100328 | None | 050 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Vol-2 (pg no 78, I No 11.6.1) | Sqm | 2764.65 | 2764.65 | 11.1 | False | None | None | False | None | False | 30687.615 | 0 |
3007088 | 100328 | None | 051 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Vol-2 (pg no 85, I No 11.28) | Kg | 632.8 | 632.8 | 236.88 | False | None | None | False | None | False | 149897.664 | 0 |
3007089 | 100328 | None | 052 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Vol-2 (pg no 50 I No 8.51) | Sqm | 105.0 | 105.0 | 2304.39 | False | None | None | False | None | False | 241960.95 | 0 |
3007090 | 100328 | None | 053 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, afterthoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life). Vol-2 (pg no 46, I No 8.33.1) | Sqm | 165.9 | 165.9 | 2304.39 | False | None | None | False | None | False | 382298.301 | 0 |
3007091 | 100328 | None | 054 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Vol-2 (pg no 46, I No 8.32) | Sqm | 163.8 | 163.8 | 384.0499 | False | None | None | False | None | False | 62907.37362 | 0 |
3007092 | 100328 | None | 055 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Vol-2 (pg no 46, I No 8.32) First Floor | Sqm | 165.44 | 165.44 | 613.21 | False | None | None | False | None | False | 101449.4624 | 0 |
3007093 | 100328 | None | 056 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Vol-2 (pg no 46, I No 8.33.2) | Sqm | 144.9 | 144.9 | 81.8 | False | None | None | False | None | False | 11852.82 | 0 |
3007094 | 100328 | None | 057 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Vol-2 (pg no 47, I No 8.33.3) | Sqm | 145.95 | 145.95 | 86.5399 | False | None | None | False | None | False | 12630.498405 | 0 |
3007095 | 100328 | None | 058 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin- Charge. Vol-2 (pg no 84, I No 11.26.1) | Kg | 144.9 | 144.9 | 1248.6 | False | None | None | False | None | False | 180922.14 | 0 |
3007096 | 100328 | None | 059 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm . Vol-2 (pg no 107, I No 12.74.1) | Nos | 107.1 | 107.1 | 40.0 | False | None | None | False | None | False | 4284.0 | 0 |
3007097 | 100328 | None | 060 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 75x47x1.80mm Vol-2 (pg no 107, I No 12.74.3) | Nos | 75.6 | 75.6 | 12.0 | False | None | None | False | None | False | 907.2 | 0 |
3007098 | 100328 | None | 061 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete Vol-2 (pg no 108, I No 12.60) | Nos | 1104.6 | 1104.6 | 13.0 | False | None | None | False | None | False | 14359.8 | 0 |
3007099 | 100328 | None | 062 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in chargee SS Tower Bolts 250x10mm Vol-2 (pg no 218, I No 22.15.7) | Nos | 210.0 | 210.0 | 10.0 | False | None | None | False | None | False | 2100.0 | 0 |
3007100 | 100328 | None | 063 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in chargee SS Tower Bolts 150x10mm Vol-2 (pg no 218, I No 22.15.5) | Nos | 126.0 | 126.0 | 3.0 | False | None | None | False | None | False | 378.0 | 0 |
3007101 | 100328 | None | 064 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in chargee SS Aldrop 16mm dia, 300mm Vol-2 (pg no 218, I No 22.15.4) | Nos | 393.75 | 393.75 | 20.0 | False | None | None | False | None | False | 7875.0 | 0 |
3007102 | 100328 | None | 065 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in chargee SS Aldrop 16mm dia, 200mm Vol-2 (pg no 218, I No 22.15.3) | Nos | 315.0 | 315.0 | 6.0 | False | None | None | False | None | False | 1890.0 | 0 |
3007103 | 100328 | None | 066 | Providing and fixing stainless steel 304 grade fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-incharge. 200mm length Vol-2 (pg no 218, I No 22.15.3) | Nos | 1575.0 | 1575.0 | 13.0 | False | None | None | False | None | False | 20475.0 | 0 |
3007104 | 100328 | None | 067 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete Vol-2 (pg no 105, I No 12.59) | Nos | 1169.7 | 1169.7 | 14.0 | False | None | None | False | None | False | 16375.8 | 0 |
3007105 | 100328 | None | 068 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New Terrace/Chajjas /Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification Vol-2 (pg no 149, I No 15.10) | Sqm | 866.43 | 866.43 | 798.59 | False | None | None | False | None | False | 691922.3337 | 0 |
3007106 | 100328 | None | 069 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/m2 (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flang s of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum moisture resistant board Vol-2 (pg no 25, I No 7.32.3) | Sqm | 1203.3 | 1203.3 | 281.93 | False | None | None | False | None | False | 339246.369 | 0 |
3007107 | 100328 | None | 070 | Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 (v) For Grading -V Material Vol-3 (pg no 23, I No 4.2 B (V)) | Cum | 2476.95 | 2476.95 | 50.47 | False | None | None | False | None | False | 125011.6665 | 0 |
3007108 | 100328 | None | 071 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course onwell prepared surface and compacting with vibratory roller to achieve the desired density. Vol-2 (pg no 26, I No 4.17) | Cum | 2686.95 | 2686.95 | 50.47 | False | None | None | False | None | False | 135610.3665 | 0 |
3007109 | 100328 | None | 072 | Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.Vol-2 (pg no 63, I No 9.25) | Sqm | 840.0 | 840.0 | 504.48 | False | None | None | False | None | False | 423763.2 | 0 |
3007110 | 100328 | None | 073 | Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 300 x 250 x 100 mm Kerb Stone Vol-3 (pg no 74, I No 8.42.1) | m | 318.15 | 318.15 | 130.0 | False | None | None | False | None | False | 41359.5 | 0 |
3007111 | 100328 | None | 074 | Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2.Vol-3 (pg no 12, I No 13.14) | Sqm | 88.2 | 88.2 | 91.0 | False | None | None | False | None | False | 8026.2 | 0 |
3007112 | 100328 | None | 075 | Providing and fixing Chorinated poly venyl cloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings,this includes jointing of pipes and fitting with one step CPVC solvent cement,trenching,refilling & testing of joints complete as per direction of Engineer incharge (external work) Item No 13.87.3 (25mm nominal OD pipes) Vol-2 (pg no 122, I No 13.33.3) | m | 310.8 | 310.8 | 75.0 | False | None | None | False | None | False | 23310.0 | 0 |
3007113 | 100328 | None | 076 | Providing and fixing Chorinated poly venyl cloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings,this includes jointing of pipes and fitting with one step CPVC solvent cement,trenching,refilling & testing of joints complete as per direction of Engineer incharge (external work) Item No 13.87.5 (40mm nominal OD pipes) Vol-2 (pg no 122, I No 13.33.5) | m | 500.85 | 500.85 | 100.0 | False | None | None | False | None | False | 50085.0 | 0 |
3007114 | 100328 | None | 077 | Providing and fixing Chorinated poly venyl cloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings,this includes jointing of pipes and fitting with one step CPVC solvent cement,trenching,refilling & testing of joints complete as per direction of Engineer incharge (external work) Item No 13.33.6 (50mm nominal OD pipes) Vol-2 (pg no 122, I No 13.33.6) | m | 757.05 | 757.05 | 80.0 | False | None | None | False | None | False | 60564.0 | 0 |
3007115 | 100328 | None | 078 | Providing and fixing Chorinated poly venyl cloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer incharge. (Concealed work including cutting chases and good the walls etc.,.) Item No 13.86.2 (20mm nominal OD pipes) Vol-2 (pg no 122, I No 13.32.2) | m | 397.95 | 397.95 | 50.0 | False | None | None | False | None | False | 19897.5 | 0 |
3007116 | 100328 | None | 079 | Providing and fixing Chorinated poly venyl cloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer incharge. (Concealed work including cutting chases and good the walls etc.,.) Item No 13.86.3 (25mm nominal OD pipes) Vol-2 (pg no 122, I No 13.32.2) | m | 500.85 | 500.85 | 30.0 | False | None | None | False | None | False | 15025.5 | 0 |
3007117 | 100328 | None | 080 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore Vol-2 (pg no 117, I No 13.4.1) | Each | 576.45 | 576.45 | 6.0 | False | None | None | False | None | False | 3458.7 | 0 |
3007118 | 100328 | None | 081 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 40 mm nominal bore Vol-2 (pg no 117, I No 13.4.3) | Each | 737.1 | 737.1 | 4.0 | False | None | None | False | None | False | 2948.4 | 0 |
3007119 | 100328 | None | 082 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 50 mm nominal bore Vol-2 (pg no 117, I No 13.4.4) | Each | 897.75 | 897.75 | 2.0 | False | None | None | False | None | False | 1795.5 | 0 |
3007120 | 100328 | None | 083 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 g. Vol-2 (pg no 119, I No 13.14) | Nos | 888.3 | 888.3 | 5.0 | False | None | None | False | None | False | 4441.5 | 0 |
3007121 | 100328 | None | 084 | Cutting holes up to 15x15cm in R.C.C floors and roofs for passing drain pipe etc., and repairing the hole after insertion of drain pipe etc., with cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including finishing complete so as to make it leak proof Vol-2 (pg no 123, I No 13.37) | No | 328.65 | 328.65 | 25.0 | False | None | None | False | None | False | 8216.25 | 0 |
3007122 | 100328 | None | 085 | Cutting holes up to 30x30cm in walls including making good the same with common burnt clay F.P.S (non modular) bricks Vol-2 (pg no 123, I No 13.36) | Each | 339.15 | 339.15 | 40.0 | False | None | None | False | None | False | 13566.0 | 0 |
3007123 | 100328 | None | 086 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 Vol-2 (pg no 119, I No 13.16) | Nos | 651.0 | 651.0 | 12.0 | False | None | None | False | None | False | 7812.0 | 0 |
3007124 | 100328 | None | 087 | Providing and fixing Bidet spray made of Stainless steel with all concealed
fitting arrangements & all necessary accesories complete - Class. Vol-2 (pg no 145, I No 14.95a) a. Economy | Each | 880.95 | 880.95 | 5.0 | False | None | None | False | None | False | 4404.75 | 0 |
3007125 | 100328 | None | 088 | Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0
cm X 4.0 cm with all fitting arrangements & all necessary accessories
complete Vol-2 (pg no 129, I No 13.63) - 1 Multifloor trap | Each | 256.2 | 256.2 | 10.0 | False | None | None | False | None | False | 2562.0 | 0 |
3007126 | 100328 | None | 089 | Providing and fixing PTMT grating of approved quality and colour Rectangular type with openable circular lid Vol-2 (pg no 120, I No 13.22.2) | No | 212.1 | 212.1 | 10.0 | False | None | None | False | None | False | 2121.0 | 0 |
3007127 | 100328 | None | 090 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for PVC pipes 75mm dia., 6 kg/sqcm & class 3 Vol-5 (pg no 113, I No 10.1.5) | m | 231.0 | 231.0 | 30.0 | False | None | None | False | None | False | 6930.0 | 0 |
3007128 | 100328 | None | 091 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. PVC pipes 110mm dia., 6 kg/sqcm & class 3 Vol-5 (pg no 113, I No 10.1.7) | m | 431.55 | 431.55 | 50.0 | False | None | None | False | None | False | 21577.5 | 0 |
3007129 | 100328 | None | 092 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring confirming to IS : 5383, leaving 10mm gap for termal expansion (i) single socketed pepes 100mm diameter Vol-2 (pg no 125, I No 13.48) | m | 305.55 | 305.55 | 68.25 | False | None | None | False | None | False | 20853.7875 | 0 |
3007130 | 100328 | None | 093 | Providing and placing on terrace, (at all floor levels) polyethylene water storage tanks IS : 12701 marked with cover and suitable locking arrangements, and making necessary holes for inlet, outlet and over flow pipes, but without fittings and the base support for tank Vol-2 (pg no 123, I No 13.34) | l | 9.45 | 9.45 | 2000.0 | False | None | None | False | None | False | 18900.0 | 0 |
3007131 | 100328 | None | 094 | Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata All kinds of soils. Depth upto 1.50 m Vol-1 (pg no 10, I No 1.17.1) | Cum | 275.1 | 275.1 | 114.3 | False | None | None | False | None | False | 31443.93 | 0 |
3007132 | 100328 | None | 095 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications Vol-1 (pg no 7, I No 1.10) | Cum | 168.0 | 168.0 | 91.8 | False | None | None | False | None | False | 15422.4 | 0 |
3007133 | 100328 | None | 096 | Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. Note: Upto 110mm dia Coil shall be used. For Grade PE80 PN8.0 : HDPE Grade PE80-PN8.0,140mm dia Vol-5 (pg no 96, I No 9.2.6) | m | 817.7 | 817.7 | 20.0 | False | None | None | False | None | False | 16354.0 | 0 |
3007134 | 100328 | None | 097 | Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. Note: Upto 110mm dia Coil shall be used. For Grade PE80 PN8.0 : HDPE Grade PE80-PN8.0,200mm dia Vol-5 (pg no 96, I No 9.2.9) | m | 1561.3 | 1561.3 | 100.0 | False | None | None | False | None | False | 156130.0 | 0 |
3007135 | 100328 | None | 098 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid Vol-2 (pg no 131, I No 14.3.1) | Each | 6275.85 | 6275.85 | 5.0 | False | None | None | False | None | False | 31379.25 | 0 |
3007136 | 100328 | None | 099 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests Vol-2 (pg no 131, I No 14.1.1) | Each | 5128.2 | 5128.2 | 1.0 | False | None | None | False | None | False | 5128.2 | 0 |
3007137 | 100328 | None | 100 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps Vol-2 (pg no 132, I No 14.7.1) | Each | 3236.1 | 3236.1 | 4.0 | False | None | None | False | None | False | 12944.4 | 0 |
3007138 | 100328 | None | 101 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. Vol-2 (pg no 137, I No 14.40.2) | Each | 520.8 | 520.8 | 4.0 | False | None | None | False | None | False | 2083.2 | 0 |
3007139 | 100328 | None | 102 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flushpipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required One urinal basin with 5 litre white P.V.C. automatic flushing cistern:Vol-2 (pg no 123, I No 14.4.1) | Each | 4676.7 | 4676.7 | 6.0 | False | None | None | False | None | False | 28060.2 | 0 |
3007140 | 100328 | None | 103 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Vol-2 (pg no 136, I No 14.31) | Each | 1281.0 | 1281.0 | 6.0 | False | None | None | False | None | False | 7686.0 | 0 |
3007141 | 100328 | None | 104 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover 180 x 150 mm size P type & With Non Modular common burnt clay bricks of designation 3.5 & frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: Vol-2 (pg no 124, I No 13.40) | Each | 2820.3 | 2820.3 | 3.0 | False | None | None | False | None | False | 8460.9 | 0 |
3007142 | 100328 | None | 105 | Providing and fixing 100 mm sand cast Iron grating for gully trap Vol-2 (pg no 136, I No 14.29) | Each | 49.35 | 49.35 | 3.0 | False | None | None | False | None | False | 148.05 | 0 |
3007143 | 100328 | None | 106 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. Vol-5 (pg no 191, I No 16.9) | Each | 5726.7 | 5726.7 | 10.0 | False | None | None | False | None | False | 57267.0 | 0 |
3007144 | 100328 | None | 107 | Supplying and fixing SFRC frame and cover conforming to IS 12592 (part-I)-1988 and IS 12592 (part-II)- 1991 with latest amendment, including cutting slabs to the required size for the opening and fixing the cover in C.C. 1:2:4 and C.M. 1:3 plastering 20 mm thick to all exposed faces, curing for 10 days with all lead and lift with appurtenances. complete Medium Duty Vol-5 (pg no 196, I No 16.23.1) | Each | 2009.7 | 2009.7 | 13.0 | False | None | None | False | None | False | 26126.1 | 0 |
3007145 | 100328 | None | 108 | Open Conduit System Supplying heavy gauge PVC conduit pipe ……….. dia ……… mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc. and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700 mm using NF screws. 19/20mm dia 2mm thick | Mtr | 72.45 | 72.45 | 100.0 | False | None | None | False | None | False | 7245.0 | 0 |
3007146 | 100328 | None | 109 | Open Conduit System Supplying heavy gauge PVC conduit pipe ……….. dia ……… mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc. and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700 mm using NF screws. 25mm dia 2mm thick | Mtr | 85.05 | 85.05 | 200.0 | False | None | None | False | None | False | 17010.0 | 0 |
3007147 | 100328 | None | 110 | Open Conduit System Supplying heavy gauge PVC conduit pipe ……….. dia ……… mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc. and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700 mm using NF screws. 32mm dia 2.5mm thick | Mtr | 111.3 | 111.3 | 35.0 | False | None | None | False | None | False | 3895.5 | 0 |
3007148 | 100328 | None | 111 | Supplying and fixing "S" hook made out of 14mm dia MS rod. | No | 54.6 | 54.6 | 9.0 | False | None | None | False | None | False | 491.4 | 0 |
3007149 | 100328 | None | 112 | Supplying and fixing MS Rafter Clamp set made out of MS Flat and 14mm dia MS rod. | No | 168.0 | 168.0 | 9.0 | False | None | None | False | None | False | 1512.0 | 0 |
3007150 | 100328 | None | 113 | Supplying and fixing metal fan box with round hook. | No | 122.85 | 122.85 | 9.0 | False | None | None | False | None | False | 1105.65 | 0 |
3007151 | 100328 | None | 114 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe ……….. mm dia ……….. mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc. and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. 19/20mm dia 2mm thick | Mtr | 69.3 | 69.3 | 200.0 | False | None | None | False | None | False | 13860.0 | 0 |
3007152 | 100328 | None | 115 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe ……….. mm dia ……….. mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc. and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick | Mtr | 81.9 | 81.9 | 500.0 | False | None | None | False | None | False | 40950.0 | 0 |
3007153 | 100328 | None | 116 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe ……….. mm dia ……….. mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc. and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. 32mm dia 2.5mm thick | Mtr | 71.4 | 71.4 | 200.0 | False | None | None | False | None | False | 14280.0 | 0 |
3007154 | 100328 | None | 117 | Supplying heavy gauge PVC conduit pipe ……….. dia ……… mm thick with suitable size bends, metal junction boxes, adhesive paste etc. by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18SWG GI fish wire run throughout the conduit wherever necessary. 25mm dia 2mm thick | Mtr | 82.95 | 82.95 | 900.0 | False | None | None | False | None | False | 74655.0 | 0 |
3007155 | 100328 | None | 118 | Supplying heavy gauge PVC conduit pipe ……….. dia ……… mm thick with suitable size bends, metal junction boxes, adhesive paste etc. by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18SWG GI fish wire run throughout the conduit wherever necessary. 32mm dia 2.5mm thick | Mtr | 103.95 | 103.95 | 45.0 | False | None | None | False | None | False | 4677.75 | 0 |
3007156 | 100328 | None | 119 | Supplying and fixing PVC/metal conduit deep junction box 19/20mm deep junction box | Each | 51.45 | 51.45 | 200.0 | False | None | None | False | None | False | 10290.0 | 0 |
3007157 | 100328 | None | 120 | Supplying and fixing PVC/metal conduit deep junction box 25mm deep junction box | Each | 58.8 | 58.8 | 100.0 | False | None | None | False | None | False | 5880.0 | 0 |
3007158 | 100328 | None | 121 | Extra for groove cutting in brick wall/CC floor to the suitable depth for concealing of conduit/GI pipe and plastering, finishing upto wall surface complete. upto 50mm conduit in brick wall | Mtr | 30.45 | 30.45 | 75.0 | False | None | None | False | None | False | 2283.75 | 0 |
3007159 | 100328 | None | 122 | Extra for groove cutting in brick wall/CC floor to the suitable depth for concealing of conduit/GI pipe and plastering, finishing upto wall surface complete. upto 50mm conduit CC floor | Mtr | 72.45 | 72.45 | 50.0 | False | None | None | False | None | False | 3622.5 | 0 |
3007160 | 100328 | None | 123 | Point wiring using copper wire without switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch | Point | 282.45 | 282.45 | 20.0 | False | None | None | False | None | False | 5649.0 | 0 |
3007161 | 100328 | None | 124 | Point wiring using copper wire without switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch | Point | 397.95 | 397.95 | 10.0 | False | None | None | False | None | False | 3979.5 | 0 |
3007162 | 100328 | None | 125 | Point wiring using copper wire without switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to out let via switch | Point | 582.75 | 582.75 | 10.0 | False | None | None | False | None | False | 5827.5 | 0 |
3007163 | 100328 | None | 126 | Point wiring using copper wire without switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr upto 6Mtr from tapping point to out let via switches. | Point | 710.85 | 710.85 | 40.0 | False | None | None | False | None | False | 28434.0 | 0 |
3007164 | 100328 | None | 127 | Point wiring using copper wire without switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6Mtr upto 10Mtr from tapping point to out let via switches. | Point | 1038.45 | 1038.45 | 45.0 | False | None | None | False | None | False | 46730.25 | 0 |
3007165 | 100328 | None | 128 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:2010 1.5 sqmm | Mtr | 27.3 | 27.3 | 350.0 | False | None | None | False | None | False | 9555.0 | 0 |
3007166 | 100328 | None | 129 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:2010 2.5 sqmm | Mtr | 44.1 | 44.1 | 2100.0 | False | None | None | False | None | False | 92610.0 | 0 |
3007167 | 100328 | None | 130 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:2010 4 sqmm | Mtr | 66.15 | 66.15 | 2800.0 | False | None | None | False | None | False | 185220.0 | 0 |
3007168 | 100328 | None | 131 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:2010 6 sqmm | Mtr | 96.6 | 96.6 | 100.0 | False | None | None | False | None | False | 9660.0 | 0 |
3007169 | 100328 | None | 132 | Supplying 6A flush type socket and 6 Amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654. 6Amps 2 Way | Each | 134.4 | 134.4 | 5.0 | False | None | None | False | None | False | 672.0 | 0 |
3007170 | 100328 | None | 133 | Supplying and mounting 2 nos. of 2 way 6 amps flush type switches either surface/flush mounted on existing gang box or in 4mm thick plastic sheet and mounted on a flush mounted wooden box and wiring as per IS 1293. | Each | 178.5 | 178.5 | 50.0 | False | None | None | False | None | False | 8925.0 | 0 |
3007171 | 100328 | None | 134 | Supplying and fixing of modular switch & connected accessories
on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch | Each | 342.3 | 342.3 | 10.0 | False | None | None | False | None | False | 3423.0 | 0 |
3007172 | 100328 | None | 135 | Supplying and fixing of modular switch & connected accessories
on existing modular switch plate as per IS 3854 and IS 1293. 16 Amps SP switch | Each | 189.0 | 189.0 | 25.0 | False | None | None | False | None | False | 4725.0 | 0 |
3007173 | 100328 | None | 136 | Supplying and fixing of modular switch & connected accessories
on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket | Each | 247.8 | 247.8 | 25.0 | False | None | None | False | None | False | 6195.0 | 0 |
3007174 | 100328 | None | 137 | Supplying and fixing of modular switch & connected accessories
on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Three way socket | Each | 179.55 | 179.55 | 8.0 | False | None | None | False | None | False | 1436.4 | 0 |
3007175 | 100328 | None | 138 | Supplying and fixing of modular switch & connected accessories
on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. | Each | 374.85 | 374.85 | 9.0 | False | None | None | False | None | False | 3373.65 | 0 |
3007176 | 100328 | None | 139 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in brick/CC wall, including necessary rawl plug, machine/NF screws etc. complete. 1-3 way | Each | 130.2 | 130.2 | 100.0 | False | None | None | False | None | False | 13020.0 | 0 |
3007177 | 100328 | None | 140 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in brick/CC wall, including necessary rawl plug, machine/NF screws etc. complete. 4-5 way | Each | 143.85 | 143.85 | 175.0 | False | None | None | False | None | False | 25173.75 | 0 |
3007178 | 100328 | None | 141 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in brick/CC wall, including necessary rawl plug, machine/NF screws etc. complete. 6 way | Each | 181.65 | 181.65 | 5.0 | False | None | None | False | None | False | 908.25 | 0 |
3007179 | 100328 | None | 142 | Supplying ….. way plastic gang box and fixing using necessary wooden/rawl/phill plugs and screws. 1 way gang box | No | 24.15 | 24.15 | 35.0 | False | None | None | False | None | False | 845.25 | 0 |
3007180 | 100328 | None | 143 | Supplying ….. way plastic gang box and fixing using necessary wooden/rawl/phill plugs and screws. 2 to 4 way gang box | No | 33.6 | 33.6 | 65.0 | False | None | None | False | None | False | 2184.0 | 0 |
3007181 | 100328 | None | 144 | Supplying ….. way plastic gang box and fixing using necessary wooden/rawl/phill plugs and screws. 6 to 10 way gang box | No | 55.65 | 55.65 | 35.0 | False | None | None | False | None | False | 1947.75 | 0 |
3007182 | 100328 | None | 145 | Supplying and fixing of metal clad industrial plugs and sockets. 2 pole + earth 250V PLUG 16 Amps | Each | 407.18 | 407.18 | 5.0 | False | None | None | False | None | False | 2035.9 | 0 |
3007183 | 100328 | None | 146 | Supplying and fixing of metal clad industrial plugs and sockets. 2 pole + earth 250V PLUG 32 Amps | Each | 575.48 | 575.48 | 5.0 | False | None | None | False | None | False | 2877.4 | 0 |
3007184 | 100328 | None | 147 | Supplying and fixing of metal clad industrial plugs and sockets 3 pole + earth 440V PLUG 16 Amps | Each | 474.73 | 474.73 | 5.0 | False | None | None | False | None | False | 2373.65 | 0 |
3007185 | 100328 | None | 148 | Supplying and fixing of metal clad industrial plugs and sockets 3 pole + earth 440V PLUG 32 Amps | Each | 640.35 | 640.35 | 2.0 | False | None | None | False | None | False | 1280.7 | 0 |
3007186 | 100328 | None | 149 | Supplying and fixing of metal clad industrial plugs and sockets 2 pole + earth 250V SOCKET 16 Amps | Each | 557.52 | 557.52 | 25.0 | False | None | None | False | None | False | 13938.0 | 0 |
3007187 | 100328 | None | 150 | Supplying and fixing of metal clad industrial plugs and sockets 2 pole + earth 250V SOCKET 32 Amps | Each | 700.39 | 700.39 | 5.0 | False | None | None | False | None | False | 3501.95 | 0 |
3007188 | 100328 | None | 151 | Supplying and fixing of metal clad industrial plugs and sockets 3 pole + earth 440V SOCKET 16 Amps | Each | 665.47 | 665.47 | 2.0 | False | None | None | False | None | False | 1330.94 | 0 |
3007189 | 100328 | None | 152 | Supplying and fixing of metal clad industrial plugs and sockets 3 pole + earth 440V SOCKET 32 Amps | Each | 869.21 | 869.21 | 2.0 | False | None | None | False | None | False | 1738.42 | 0 |
3007190 | 100328 | None | 153 | Supplying and fixing surface/flush mounting powder coated / galvanised metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / CC wall. 1-3 way | Each | 166.95 | 166.95 | 50.0 | False | None | None | False | None | False | 8347.5 | 0 |
3007191 | 100328 | None | 154 | Supplying and fixing surface/flush mounting powder coated / galvanised metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / CC wall. 4-5 way | Each | 185.85 | 185.85 | 75.0 | False | None | None | False | None | False | 13938.75 | 0 |
3007192 | 100328 | None | 155 | Supplying and fixing surface/flush mounting powder coated / galvanised metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / CC wall. 6 way | Each | 231.0 | 231.0 | 25.0 | False | None | None | False | None | False | 5775.0 | 0 |
3007193 | 100328 | None | 156 | Supplying and fixing surface/flush mounting powder coated / galvanised metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / CC wall. 8 way | Each | 274.05 | 274.05 | 15.0 | False | None | None | False | None | False | 4110.75 | 0 |
3007194 | 100328 | None | 157 | Supplying and fixing surface/flush mounting powder coated / galvanised metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / CC wall. 10-12 way | Each | 334.95 | 334.95 | 10.0 | False | None | None | False | None | False | 3349.5 | 0 |
3007195 | 100328 | None | 158 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts, nuts etc. complete on the existing metal / PVC box. 1 to 3 module | Each | 169.05 | 169.05 | 75.0 | False | None | None | False | None | False | 12678.75 | 0 |
3007196 | 100328 | None | 159 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts, nuts etc. complete on the existing metal / PVC box. 4 module | Each | 183.75 | 183.75 | 50.0 | False | None | None | False | None | False | 9187.5 | 0 |
3007197 | 100328 | None | 160 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts, nuts etc. complete on the existing metal / PVC box. 6 module | Each | 245.7 | 245.7 | 25.0 | False | None | None | False | None | False | 6142.5 | 0 |
3007198 | 100328 | None | 161 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts, nuts etc. complete on the existing metal / PVC box. 8 module | Each | 298.2 | 298.2 | 20.0 | False | None | None | False | None | False | 5964.0 | 0 |
3007199 | 100328 | None | 162 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts, nuts etc. complete on the existing metal / PVC box. 10-12 module | Each | 361.2 | 361.2 | 10.0 | False | None | None | False | None | False | 3612.0 | 0 |
3007200 | 100328 | None | 163 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator / dimmer / telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293. 6 Amps one way | Each | 107.1 | 107.1 | 35.0 | False | None | None | False | None | False | 3748.5 | 0 |
3007201 | 100328 | None | 164 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator / dimmer / telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293. 6 Amps two way | Each | 174.3 | 174.3 | 25.0 | False | None | None | False | None | False | 4357.5 | 0 |
3007202 | 100328 | None | 165 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator / dimmer / telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293. 6 Amps 3 way socket | Each | 179.55 | 179.55 | 10.0 | False | None | None | False | None | False | 1795.5 | 0 |
3007203 | 100328 | None | 166 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator / dimmer / telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293. Stepped fan regulator | Each | 374.85 | 374.85 | 10.0 | False | None | None | False | None | False | 3748.5 | 0 |
3007204 | 100328 | None | 167 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator / dimmer / telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293. 600 watts dimmer | Each | 289.8 | 289.8 | 5.0 | False | None | None | False | None | False | 1449.0 | 0 |
3007205 | 100328 | None | 168 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator / dimmer / telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293. 1000-1200 watts dimmer | Each | 345.45 | 345.45 | 4.0 | False | None | None | False | None | False | 1381.8 | 0 |
3007206 | 100328 | None | 169 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator / dimmer / telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293. 16 Amps one way switch | Each | 189.0 | 189.0 | 20.0 | False | None | None | False | None | False | 3780.0 | 0 |
3007207 | 100328 | None | 170 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator / dimmer / telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293. 6 Amps bell push | Each | 185.85 | 185.85 | 2.0 | False | None | None | False | None | False | 371.7 | 0 |
3007208 | 100328 | None | 171 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator / dimmer / telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293. 32 Amps DP switch | Each | 342.3 | 342.3 | 2.0 | False | None | None | False | None | False | 684.6 | 0 |
3007209 | 100328 | None | 172 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator / dimmer / telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293. 6/16 Amps universal socket | Each | 247.8 | 247.8 | 20.0 | False | None | None | False | None | False | 4956.0 | 0 |
3007210 | 100328 | None | 173 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator / dimmer / telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone socket | Each | 163.8 | 163.8 | 10.0 | False | None | None | False | None | False | 1638.0 | 0 |
3007211 | 100328 | None | 174 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator / dimmer / telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293. RJ45/I.O outlet | Each | 353.85 | 353.85 | 2.0 | False | None | None | False | None | False | 707.7 | 0 |
3007212 | 100328 | None | 175 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' type curve, indicator ON / OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC-60898. 6-32 Amps SP | Each | 435.75 | 435.75 | 15.0 | False | None | None | False | None | False | 6536.25 | 0 |
3007213 | 100328 | None | 176 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' type curve, indicator ON / OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC-60898. 40 Amps SP | Each | 832.65 | 832.65 | 12.0 | False | None | None | False | None | False | 9991.8 | 0 |
3007214 | 100328 | None | 177 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' type curve, indicator ON / OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC-60898. 6-32 Amps DP | Each | 1113.0 | 1113.0 | 20.0 | False | None | None | False | None | False | 22260.0 | 0 |
3007215 | 100328 | None | 178 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' type curve, indicator ON / OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC-60898. 6-32 Amps TPN | Each | 1802.85 | 1802.85 | 20.0 | False | None | None | False | None | False | 36057.0 | 0 |
3007216 | 100328 | None | 179 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' type curve, indicator ON / OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC-60898. 50-63 Amps TPN | Each | 3242.4 | 3242.4 | 20.0 | False | None | None | False | None | False | 64848.0 | 0 |
3007217 | 100328 | None | 180 | Supplying and fixing of regular MCB distribution boards on wall/wood board/flush mounting using required clamps, bolts, nuts etc. with provision for fixing suitable type capacity MCB's single phase / 3phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. I-Single Door 4way SP & N | Each | 1303.05 | 1303.05 | 2.0 | False | None | None | False | None | False | 2606.1 | 0 |
3007218 | 100328 | None | 181 | Supplying and fixing of regular MCB distribution boards on wall/wood board/flush mounting using required clamps, bolts, nuts etc. with provision for fixing suitable type capacity MCB's single phase / 3phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. II-Double Door 8way SP & N | Each | 1946.7 | 1946.7 | 1.0 | False | None | None | False | None | False | 1946.7 | 0 |
3007219 | 100328 | None | 182 | Supplying and fixing of regular MCB distribution boards on wall/wood board/flush mounting using required clamps, bolts, nuts etc. with provision for fixing suitable type capacity MCB's single phase / 3phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. III-Double Door 4way TP & N | Each | 4239.9 | 4239.9 | 2.0 | False | None | None | False | None | False | 8479.8 | 0 |
3007220 | 100328 | None | 183 | Supplying and fixing of regular MCB distribution boards on wall/wood board/flush mounting using required clamps, bolts, nuts etc. with provision for fixing suitable type capacity MCB's single phase / 3phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. III-Double Door 6way TP & N | Each | 5187.0 | 5187.0 | 2.0 | False | None | None | False | None | False | 10374.0 | 0 |
3007221 | 100328 | None | 184 | Supplying, fixing and wiring Residual current Circuit Breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/panel board. 16-25 Amps 2pole | Each | 4490.85 | 4490.85 | 15.0 | False | None | None | False | None | False | 67362.75 | 0 |
3007222 | 100328 | None | 185 | Supplying, fixing and wiring Residual current Circuit Breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/panel board. 32-40 Amps 2pole | Each | 4786.95 | 4786.95 | 15.0 | False | None | None | False | None | False | 71804.25 | 0 |
3007223 | 100328 | None | 186 | Supplying, fixing and wiring Residual current Circuit Breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/panel board. 32-40 Amps 4pole | Each | 5404.35 | 5404.35 | 20.0 | False | None | None | False | None | False | 108087.0 | 0 |
3007224 | 100328 | None | 187 | Supplying, fixing and wiring Residual current Circuit Breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/panel board. 63 Amps 4pole | Each | 5822.25 | 5822.25 | 24.0 | False | None | None | False | None | False | 139734.0 | 0 |
3007225 | 100328 | None | 188 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5mtr. Long buried in a pit ……. The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc. is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc. The pipe shall have 16 through holes of 122mm dia. | No | 3685.5 | 3685.5 | 4.0 | False | None | None | False | None | False | 14742.0 | 0 |
3007226 | 100328 | None | 189 | Supplying, fixing and wiring earth electrode for grounding of lifts, Transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. | No | 4468.8 | 4468.8 | 4.0 | False | None | None | False | None | False | 17875.2 | 0 |
3007227 | 100328 | None | 190 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. GI strip 25x3mm | Mtr | 86.1 | 86.1 | 200.0 | False | None | None | False | None | False | 17220.0 | 0 |
3007228 | 100328 | None | 191 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. GI strip 25x6mm | Mtr | 134.4 | 134.4 | 150.0 | False | None | None | False | None | False | 20160.0 | 0 |
3007229 | 100328 | None | 192 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. GI strip 40x6mm | Mtr | 190.05 | 190.05 | 30.0 | False | None | None | False | None | False | 5701.5 | 0 |
3007230 | 100328 | None | 193 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. GI strip 50x6mm | Mtr | 228.9 | 228.9 | 40.0 | False | None | None | False | None | False | 9156.0 | 0 |
3007231 | 100328 | None | 194 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. GI strip 600x600x3mm GI plate | Each | 918.75 | 918.75 | 5.0 | False | None | None | False | None | False | 4593.75 | 0 |
3007232 | 100328 | None | 195 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm copper strip 25x6mm | Mtr | 598.5 | 598.5 | 25.0 | False | None | None | False | None | False | 14962.5 | 0 |
3007233 | 100328 | None | 196 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm copper strip40x6mm | Mtr | 1155.0 | 1155.0 | 70.0 | False | None | None | False | None | False | 80850.0 | 0 |
3007234 | 100328 | None | 197 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm CU plate | Each | 7792.05 | 7792.05 | 2.0 | False | None | None | False | None | False | 15584.1 | 0 |
3007235 | 100328 | None | 198 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-39754 core 16sq.mm | Mtr | 148.93 | 148.93 | 100.0 | False | None | None | False | None | False | 14893.0 | 0 |
3007236 | 100328 | None | 199 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 25sq.mm | Mtr | 146.53 | 146.53 | 35.0 | False | None | None | False | None | False | 5128.55 | 0 |
3007237 | 100328 | None | 200 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 120sq.mm | Mtr | 479.73 | 479.73 | 100.0 | False | None | None | False | None | False | 47973.0 | 0 |
3007238 | 100328 | None | 201 | Supplying exhaust fan of 1440 rpm of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC supply. | Each | 1566.6 | 1566.6 | 3.0 | False | None | None | False | None | False | 4699.8 | 0 |
3007239 | 100328 | None | 202 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374 / 79 and also comply with IS:1709 / 1984 with latest amendment, Rated voltage 220 V / 50 Hz. Rated power input 48 W +/- 10%, Rated current As per IS:374 / 79, Rated power factor 0.9 lagging (min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / Watt, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor wdg. Temp rise Shall not exceed 75 deg C over and ambient of 400C by resistance method at 245 Volts, Insulation resistance Shall not be less than Two Mega Ohms (2 M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, watt& current, Air Delivery & Fan Speed as per IS:374 / 1979 with latest amendment, 2 year manufacturer Warranty. 48" sweep 5 Star (1200mm) | Each | 2810.85 | 2810.85 | 9.0 | False | None | None | False | None | False | 25297.65 | 0 |
3007240 | 100328 | None | 203 | Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x 2' - 9/10w | Each | 578.55 | 578.55 | 4.0 | False | None | None | False | None | False | 2314.2 | 0 |
3007241 | 100328 | None | 204 | Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w | Each | 724.5 | 724.5 | 2.0 | False | None | None | False | None | False | 1449.0 | 0 |
3007242 | 100328 | None | 205 | down light ...... W luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power/COB with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 1) 5-6W | Each | 845.25 | 845.25 | 15.0 | False | None | None | False | None | False | 12678.75 | 0 |
3007243 | 100328 | None | 206 | Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED square or round down light 10-12W | Each | 929.25 | 929.25 | 21.0 | False | None | None | False | None | False | 19514.25 | 0 |
3007244 | 100328 | None | 207 | Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED square or round down light 15-18W | No | 1390.2 | 1390.2 | 72.0 | False | None | None | False | None | False | 100094.4 | 0 |
3007245 | 100328 | None | 208 | Supplying of recess mounting non integral type ........LED ...... W luminaire comprising of pressure decast / extruded aluminium housing, with spring loaded fase ceiling clamps. Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit. THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 1'x1' 18W | No | 3294.9 | 3294.9 | 3.0 | False | None | None | False | None | False | 9884.7 | 0 |
3007246 | 100328 | None | 209 | Supplying of recess mounting non integral type ........LED ...... W luminaire comprising of pressure decast / extruded aluminium housing, with spring loaded fase ceiling clamps. Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80.
The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit. THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 2'x2' 36watt | No | 4780.65 | 4780.65 | 4.0 | False | None | None | False | None | False | 19122.6 | 0 |
3007247 | 100328 | None | 210 | Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/ clear glass material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. LED Efficiency130lm/w, nominal CRI 75.
Luminaire manufacturer should have inhouse facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing / Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree / Nichia / Lumileds / Osram make LED Source. LED Post Top Lantern with 25/30 Watts | No | 8108.1 | 8108.1 | 4.0 | False | None | None | False | None | False | 32432.4 | 0 |
3007248 | 100328 | None | 211 | Supplying and fixing one of 230Volts ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws. | Each | 258.3 | 258.3 | 2.0 | False | None | None | False | None | False | 516.6 | 0 |
3007249 | 100328 | None | 212 | Supplying, installing and commissioning Portable Fire extinguishers of following type & capacity. ABC type fire extinguisher of 6 Kgs. Capacity, with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket etc. complete MR | Each | 4500.0 | 4500.0 | 4.0 | False | None | None | False | None | False | 18000.0 | 0 |
3007250 | 100328 | None | 213 | Fixing all types and all capacities of fluorescent / false ceiling/ spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076 twin twisted PVC insulated wires, required nos. of round blocks and clamps. On wall / ceiling / rafter / giders | Each | 128.1 | 128.1 | 112.0 | False | None | None | False | None | False | 14347.2 | 0 |
3007251 | 100328 | None | 214 | Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts 5 Amps Ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire. | Each | 516.6 | 516.6 | 3.0 | False | None | None | False | None | False | 1549.8 | 0 |
3007252 | 100328 | None | 215 | Fixing a ceiling / wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 Amps. Ceiling rose, necessary length of 23/0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 179.55 | 179.55 | 9.0 | False | None | None | False | None | False | 1615.95 | 0 |
3007253 | 100328 | None | 216 | Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, Air-conditioning supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 1 KVA ON LINE UPS 19 MIN BACK UP | Each | 34857.9 | 34857.9 | 1.0 | False | None | None | False | None | False | 34857.9 | 0 |
3007254 | 100328 | None | 217 | Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, Air-conditioning supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 3 KVA ON LINE UPS 19 MIN BACKUP | Each | 50371.65 | 50371.65 | 1.0 | False | None | None | False | None | False | 50371.65 | 0 |
3007255 | 100328 | None | 218 | Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, Air-conditioning supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 5 KVA ON LINE UPS | Each | 83130.6 | 83130.6 | 1.0 | False | None | None | False | None | False | 83130.6 | 0 |
3007256 | 100328 | None | 219 | Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 26 AH capacity | Each | 4725.0 | 4725.0 | 20.0 | False | None | None | False | None | False | 94500.0 | 0 |
3007257 | 100328 | None | 220 | Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 42 AH capacity | Each | 7635.6 | 7635.6 | 2.0 | False | None | None | False | None | False | 15271.2 | 0 |
3007258 | 100328 | None | 221 | Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 75 / 80 AH capacity | Each | 10680.6 | 10680.6 | 3.0 | False | None | None | False | None | False | 32041.8 | 0 |
3007259 | 100328 | None | 222 | Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, Air-conditioning supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 1 KVA ON LINE UPS 19 MIN BACK UP | Each | 24830.4 | 24830.4 | 1.0 | False | None | None | False | None | False | 24830.4 | 0 |
3007260 | 100328 | None | 223 | Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, Air-conditioning supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 3 KVA ON LINE UPS 19 MIN BACKUP | Each | 40654.95 | 40654.95 | 2.0 | False | None | None | False | None | False | 81309.9 | 0 |
3007261 | 100328 | None | 224 | Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, Air-conditioning supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 5 KVA ON LINE UPS 30 MIN BACKUP | Each | 71802.15 | 71802.15 | 1.0 | False | None | None | False | None | False | 71802.15 | 0 |
3007262 | 100328 | None | 225 | Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 26 AH capacity | Each | 3791.55 | 3791.55 | 20.0 | False | None | None | False | None | False | 75831.0 | 0 |
3007263 | 100328 | None | 226 | Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 42 AH capacity | Each | 5346.6 | 5346.6 | 2.0 | False | None | None | False | None | False | 10693.2 | 0 |
3007264 | 100328 | None | 227 | Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 75 / 80 AH capacity | Each | 10680.6 | 10680.6 | 3.0 | False | None | None | False | None | False | 32041.8 | 0 |
3007265 | 100328 | None | 228 | Supplying, installing, testing and commissioning of Diesel Generator set 200 kVA / 160 kW and as per schedule-B attached. | Each | 1678100.55 | 1678100.55 | 1.0 | False | None | None | False | None | False | 1678100.55 | 0 |
3007266 | 100328 | None | 229 | Supply, Erection, testing and commissioning of AMF panel suitable for 200KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .....A 4 pole contactor for alternator with thermal O/L relay,..... A 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, ........capacity bypass switch and frequency sensing, PCC 1301controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ kVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMF module by pass Mode, Battery charger unit with inbuilt Auto/Manual and Flat/Boost facility. The complete set shall have sufficient safety and adhere to NEC, NBC 2016, IEC, CPWD specifications, PCB norms and KSGEI Acts and Rules. 200KVA | Each | 241739.4 | 241739.4 | 1.0 | False | None | None | False | None | False | 241739.4 | 0 |
3007267 | 100328 | None | 230 | Fabricating, supplying and erecting swaged tubular pole of height …Mtr having three sections, and providing two coats of red oxide paint and finished with two coats of enamelled paint of approved quality and colour and M.S. base plate of suitable size welded at the bottom of the pole(as per IS) and 40mm dia GI / flexible PVC pipe of 1 mtr length fitted to the heavy gauge polycarbonate control box including 5way connector of size 167x125x82mm for 7.5M pole/200x160x98mm for remaining length of pole with front opening cover, with locking arrangements and suitable capacity MCB / DP switch, The pole shall be erected in cement concrete work (1:2:4) including excavation and refilling of planting depth of the pole to the ground level and the coping CC shall be up to 0.6M above ground level as per IS 2713 - 7. Erection of heavy duty pole on footpath / median 9Mt (5Mt Hb,165.1mm dia 4.85mm thick x2M Hm, 139.7mm dia 4.50mm thick x 2M Ht,114.3mm dia 3.65mm thick) as per IS 410 SP 32. | Each | 16275.0 | 16275.0 | 30.0 | False | None | None | False | None | False | 488250.0 | 0 |
3007268 | 100328 | None | 231 | Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length | Each | 1534.05 | 1534.05 | 20.0 | False | None | None | False | None | False | 30681.0 | 0 |
3007269 | 100328 | None | 232 | Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Double bracket 2x1.5 Mtr. Length | Each | 2451.75 | 2451.75 | 10.0 | False | None | None | False | None | False | 24517.5 | 0 |
3007270 | 100328 | None | 233 | Supply of LED street light with pressure die cast aluminium housing body with optimal heat sink for better thermal dissipation. Diffuser with injection module and is made of polycarbonate material with high transmission index, delivering superior light output. Rated life burning Hrs. 50000 Hrs. at lumen maintenance of 70%. CCT 5500K, IP66 optical and electrical compartment and impact resistance of complete luminaire IK 08. power factor 0.9 with mains current should not be greater than 0.1A to 0.7A and surge protection - min. 4 kV along with over voltage / over load, short circuit / mis-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Over load and short circuit protection ensures reliable operation in spite of problem in output side. Compliance to IS10322/IEC 60598, LM 79 and LM 80 adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimised minimal tools. LED light fixture with ...... watts system power consumption. LED efficiency 130 lm / w at 1 W and fixture efficiency 80lm/w with nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI and any Govt. certified agency and design and development facility certified by ISO 9001;2008. Housing with supplier word mark / name shall be engrave / embossing on the die cast housing / body part. Warranty of 5 years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED source manufacturer. Suitable for B1/B2 roads as per IS 1944 Part-I and Part-II. LED Streetlight 70watts | No | 6711.04 | 6711.04 | 30.0 | False | None | None | False | None | False | 201331.2 | 0 |
3007271 | 100328 | None | 234 | Fixing charges of post top/gate/garden fitting / LED on the existing CI / GI or any other pipe using required size of reducer, wiring using suitable wires. | Each | 221.76 | 221.76 | 4.0 | False | None | None | False | None | False | 887.04 | 0 |