1710310429000 | 1 | None | None | Other Works | Construction of new mess block with kitchen at Veterinary College Bidar | 15695770.91 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3029891 | 102075 | None | code01 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. | ha | 208523.7 | 208523.7 | 0.25 | False | None | None | False | None | False | 52130.925 | 0 | 3029892 | 102075 | None | code02 | Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all worksother than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shor ing, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In all kinds of soil upto 300 mm depth. | Cum | 86.73 | 86.73 | 270.0 | False | None | None | False | None | False | 23417.1 | 0 | 3029893 | 102075 | None | code03 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels,key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading,caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to
complete the work. In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 283.73 | 283.73 | 265.83 | False | None | None | False | None | False | 75423.9459 | 0 | 3029894 | 102075 | None | code04 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 ltr/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 117.71 | 117.71 | 700.0 | False | None | None | False | None | False | 82397.0 | 0 | 3029895 | 102075 | None | code05 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/ trap / basalt crushed graded coarse aggregatesand fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators,including all lead & lifts, cost of all materials of quality,labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately).Mix 1:4:8( M5) Using 40 mm and down size graded crushed coarse aggregates. | Cum | 6450.23 | 6450.23 | 98.66 | False | None | None | False | None | False | 636379.6918 | 0 | 3029896 | 102075 | None | code06 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates | Cum | 7407.98 | 7407.98 | 58.08 | False | None | None | False | None | False | 430255.4784 | 0 | 3029897 | 102075 | None | code07 | Frame work | Cum | 592.64 | 592.64 | 58.08 | False | None | None | False | None | False | 34420.5312 | 0 | 3029898 | 102075 | None | code08 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates | Cum | 7407.98 | 7407.98 | 20.82 | False | None | None | False | None | False | 154234.1436 | 0 | 3029899 | 102075 | None | code09 | Frame work of Columns | Cum | 5185.59 | 5185.59 | 20.8 | False | None | None | False | None | False | 107860.272 | 0 | 3029900 | 102075 | None | code10 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates | Cum | 7407.98 | 7407.98 | 17.76 | False | None | None | False | None | False | 131565.7248 | 0 | 3029901 | 102075 | None | code11 | Frame work of Plinth Beams | Cum | 3703.99 | 3703.99 | 17.76 | False | None | None | False | None | False | 65782.8624 | 0 | 3029902 | 102075 | None | code12 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates | Cum | 7407.98 | 7407.98 | 67.46 | False | None | None | False | None | False | 499742.3308 | 0 | 3029903 | 102075 | None | code13 | Frame work of Roof Beams & Lintel | Cum | 4444.79 | 4444.79 | 67.68 | False | None | None | False | None | False | 300823.3872 | 0 | 3029904 | 102075 | None | code14 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates | Cum | 7407.98 | 7407.98 | 82.51 | False | None | None | False | None | False | 611232.4298 | 0 | 3029905 | 102075 | None | code15 | Frame work of Roof Slab | Cum | 3703.99 | 3703.99 | 82.51 | False | None | None | False | None | False | 305616.2149 | 0 | 3029906 | 102075 | None | code16 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates | Cum | 7407.98 | 7407.98 | 5.0 | False | None | None | False | None | False | 37039.9 | 0 | 3029907 | 102075 | None | code17 | Frame work of RCC Stairecase | Cum | 5926.38 | 5926.38 | 5.0 | False | None | None | False | None | False | 29631.9 | 0 | 3029908 | 102075 | None | code18 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | Kgs | 113.99 | 113.99 | 26764.4 | False | None | None | False | None | False | 3050873.956 | 0 | 3029909 | 102075 | None | code19 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceed ing 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 252.76 | 252.76 | 265.83 | False | None | None | False | None | False | 67191.1908 | 0 | 3029910 | 102075 | None | code20 | Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 498.08 | 498.08 | 574.36 | False | None | None | False | None | False | 286077.2288 | 0 | 3029911 | 102075 | None | code21 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with CM 1:6 (1cement : 6 coarse sand). | Cum | 5976.94 | 5976.94 | 57.32 | False | None | None | False | None | False | 342598.2008 | 0 | 3029912 | 102075 | None | code22 | Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6952.03 | 6952.03 | 29.46 | False | None | None | False | None | False | 204806.8038 | 0 | 3029913 | 102075 | None | code23 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap / basalt crushed graded coarse aggregate sand fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality,labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)..Mix 1:3:6 (M10) Using 20 mm and down size graded crushed coarse aggregates | Cum | 7342.31 | 7342.31 | 15.0 | False | None | None | False | None | False | 110134.65 | 0 | 3029914 | 102075 | None | code24 | Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 9562.6 | 9562.6 | 200.01 | False | None | None | False | None | False | 1912615.626 | 0 | 3029915 | 102075 | None | code25 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand)including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Sqm | 1125.01 | 1125.01 | 19.44 | False | None | None | False | None | False | 21870.1944 | 0 | 3029916 | 102075 | None | code26 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 349.4 | 349.4 | 721.12 | False | None | None | False | None | False | 251959.328 | 0 | 3029917 | 102075 | None | code27 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:3 (1 cement: 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materi als, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 397.72 | 397.72 | 1225.78 | False | None | None | False | None | False | 487517.2216 | 0 | 3029918 | 102075 | None | code28 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 387.81 | 387.81 | 881.9 | False | None | None | False | None | False | 342009.639 | 0 | 3029919 | 102075 | None | code29 | Providing and fixing stainless steel 304 grade for staircase railings,balconies ,ramps , with hand rail,50mm dia 16 guage hollow pipe welded to vertical hollow 50mm dia 16 guage, stainless steel vertical pipe spaced at 1.2m regular intervals and 5nos of 25mm dia. stainless steel hollow horizontal pipe arre welded to vertical 50mm dia hollow pipe.the entire assembly is fixed to staircase concrete by using expansion bolts by drilling concrete etc. complete including cost of materials ,labour,HOM of and electrical charges etc complete as per specifications. | Sqm | 619.5 | 619.5 | 132.77 | False | None | None | False | None | False | 82251.015 | 0 | 3029920 | 102075 | None | code30 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, Lakared, River Pink or equivalent. | Sqm | 2352.86 | 2352.86 | 566.85 | False | None | None | False | None | False | 1333718.691 | 0 | 3029921 | 102075 | None | code31 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. | Sqm | 957.75 | 957.75 | 92.86 | False | None | None | False | None | False | 88936.665 | 0 | 3029922 | 102075 | None | code32 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). | Kgs | 148.68 | 148.68 | 1500.0 | False | None | None | False | None | False | 223020.0 | 0 | 3029923 | 102075 | None | code33 | Providing Teak wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves ( excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 291969.11 | 291969.11 | 1.5 | False | None | None | False | None | False | 437953.665 | 0 | 3029924 | 102075 | None | code34 | Main Door ShuttersTeak | Sqm | 9554.52 | 9554.52 | 4.8 | False | None | None | False | None | False | 45861.696 | 0 | 3029925 | 102075 | None | code35 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets ( core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 ( part-I) 1991. from manufacturer complete as per spcification. 30 mm thick Both side teak | Sqm | 4086.22 | 4086.22 | 30.93 | False | None | None | False | None | False | 126386.7846 | 0 | 3029926 | 102075 | None | code36 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and rein forced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm x 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement.Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, stand ard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size.1219mm x1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 5097.25 | 5097.25 | 89.82 | False | None | None | False | None | False | 457834.995 | 0 | 3029927 | 102075 | None | code37 | Providing and applying white cement based putty of average thick ness 1 mm, of approved brand and manufacturer, over the plastered
wall surface to prepare the surface even and smooth complete as per
specifications and as per directions of Engineer in charge. | Sqm | 102.84 | 102.84 | 1946.9 | False | None | None | False | None | False | 200219.196 | 0 | 3029928 | 102075 | None | code38 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 130.1 | 130.1 | 1946.9 | False | None | None | False | None | False | 253291.69 | 0 | 3029929 | 102075 | None | code39 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 81.77 | 81.77 | 881.9 | False | None | None | False | None | False | 72112.963 | 0 | 3029930 | 102075 | None | code40 | Painting with synthetic enamel paint of approved brand and manu facture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth,cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 111.51 | 111.51 | 170.93 | False | None | None | False | None | False | 19060.4043 | 0 | 3029931 | 102075 | None | code41 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete. (Concealed work including cutting chases and good the walls etc.) CPVC pipe dia 25mm | Rmtr | 363.03 | 363.03 | 60.0 | False | None | None | False | None | False | 21781.8 | 0 | 3029932 | 102075 | None | code42 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete. (Concealed work including cutting chases and good the walls etc.) CPVC pipe dia 32mm | Rmtr | 463.39 | 463.39 | 45.0 | False | None | None | False | None | False | 20852.55 | 0 | 3029933 | 102075 | None | code43 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete. (Concealed work including cutting chases and good the walls etc.) CPVC pipe dia 40mm | Rmtr | 361.79 | 361.79 | 40.0 | False | None | None | False | None | False | 14471.6 | 0 | 3029934 | 102075 | None | code44 | Providing and fixing to wall, ceiling and floor high density polyethylene pipes 6.00 kgf/sq.cm working pressure --mm outside diameter with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor, including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications. PVC Pipe Dia 75mm | Rmtr | 526.58 | 526.58 | 30.0 | False | None | None | False | None | False | 15797.4 | 0 | 3029935 | 102075 | None | code45 | Providing and fixing to wall, ceiling and floor high density polyethylene pipes 6.00 kgf/sq.cm working pressure --mm outside diameter with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor, including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications. PVC Pipe Dia 90mm | Rmtr | 617.02 | 617.02 | 20.0 | False | None | None | False | None | False | 12340.4 | 0 | 3029936 | 102075 | None | code46 | Providing and fixing to wall, ceiling and floor high density polyethylene pipes 6.00 kgf/sq.cm working pressure --mm outside diameter with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor, including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications. PVC Pipe Dia 110mm | Rmtr | 737.21 | 737.21 | 45.0 | False | None | None | False | None | False | 33174.45 | 0 | 3029937 | 102075 | None | code47 | Providing and fixing to wall, ceiling and floor unplasticised PVC 6.00 kgf/sq.cm working pressure --mm outside diameter with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor, including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications. | Rmtr | 1056.87 | 1056.87 | 50.0 | False | None | None | False | None | False | 52843.5 | 0 | 3029938 | 102075 | None | code48 | Providing and fixing in position brass stop cock of approved quality 25mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. | Each | 172.22 | 172.22 | 8.0 | False | None | None | False | None | False | 1377.76 | 0 | 3029939 | 102075 | None | code49 | KSRB13-6.1-3 : Providing and fixing in position brass bib cock of approved quality 25mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. | Each | 292.4 | 292.4 | 8.0 | False | None | None | False | None | False | 2339.2 | 0 | 3029940 | 102075 | None | code50 | Providing and fixing in position brass gate valve with C.I wheel of approved quality ( screwed end )--mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. Gate Valve 25mm | Each | 556.31 | 556.31 | 5.0 | False | None | None | False | None | False | 2781.55 | 0 | 3029941 | 102075 | None | code51 | Gate Valve 40mm | Each | 1288.56 | 1288.56 | 3.0 | False | None | None | False | None | False | 3865.68 | 0 | 3029942 | 102075 | None | code52 | Providing and placing on terrace, polyethylene water storage tanks with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes, including cost of all materials, labour, transport charges, HOM of equipments and testing complete as per specifications. | Each | 8459.89 | 8459.89 | 2.0 | False | None | None | False | None | False | 16919.78 | 0 | 3029943 | 102075 | None | code53 | Providing and fixing white vitreous china clay, water closet European type ( Pedestal type, P-trap ) with black solid plastic seat and lid, C.P brass hinges, rubber buffers. 10 litre low level, P.V.C flushing cistern ( all are approved make ) with fittings, C.I / M.S brackets, 40mm diameter flush bend with fittings and clamps, overflow arrangements with special and 25mm mosquito proof coupling of approved design, painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour complete as per specifications. | Each | 6140.48 | 6140.48 | 1.0 | False | None | None | False | None | False | 6140.48 | 0 | 3029944 | 102075 | None | code54 | Providing and fixing white vitreous china clay, water closet Indian type ( Squatting pan ) of size 580mm with footrests, 100mm S or P trap, 10 litre low level, P.V.C flushing cistern ( all are approved make ) with fittings, C.I / M.S brackets, 32mm diameter flush pipe fittings and clamps, overflow arrangements with specials and 25mm mosquito proof coupling of approved design, painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour complete as per specifications. | Each | 4355.09 | 4355.09 | 1.0 | False | None | None | False | None | False | 4355.09 | 0 | 3029945 | 102075 | None | code55 | KSRB13-6.7-2 : Providing and fixing in position chromium plated brass shower rose with 15 or 20mm inlet 150mm dia including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. | Each | 929.25 | 929.25 | 2.0 | False | None | None | False | None | False | 1858.5 | 0 | 3029946 | 102075 | None | code56 | Providing and fixing CI Nahani trap of approved make conforming to ISI specifications and construction of Cistern in M-15 as per directions (Rate is inclusive of cost of materials and fixtures and conveyance of materials to work spot). - 10cms x 7.5cms Nani Trap 10 cms | Each | 309.75 | 309.75 | 6.0 | False | None | None | False | None | False | 1858.5 | 0 | 3029947 | 102075 | None | code57 | Providing and fixing 453x357mm dia rectangular shape mirror with plastic moulded frame of approved make and shade with 6mm thick hard board backing including cost of materials, labour complete as per specifications. | Each | 1407.5 | 1407.5 | 4.0 | False | None | None | False | None | False | 5630.0 | 0 | 3029948 | 102075 | None | code58 | Providing and fixing white vitreous china clay, flat back wash basin size 630x450mm with a pair of 15mm C.P brass pillar taps with C.I / M.S brackets, 32 mm C.P. brass waste of standard pattern, painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour complete as per specifications. | Each | 4964.67 | 4964.67 | 8.0 | False | None | None | False | None | False | 39717.36 | 0 | 3029949 | 102075 | None | code59 | Constructing brick masonry inspection chamber 455x610mm, and 450mm depth, ( clear inside dimension ) for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover withframe (light duty) 455x610mm internal dimensions, total weight of cover with frame to be not less than 38 kg ( weight of cover 23kg and weight of frame 15 kg) R.C.C. top slab with cement concrete M 15 with 20mm and downsize granite metal, foundation concrete M 5 with 40mm and downsize granite metal inside plastering 12mm thick with cement mortar 1:3, finish smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials, labour charges, curing complete as per specifications. Inspection Chember | Each | 8931.95 | 8931.95 | 8.0 | False | None | None | False | None | False | 71455.6 | 0 | 3029950 | 102075 | None | code60 | Inspection Chember 600x600mm | Each | 10519.11 | 10519.11 | 9.0 | False | None | None | False | None | False | 94671.99 | 0 | 3029951 | 102075 | None | code61 | Constructing brick masonry circular type manhole 1.52 m internal dia at bottom, 2.30m deep and 0.56m dia at top, with table moulded and non-modular bricks of class designation 50 in cement mortar 1:4, inside cement plaster 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 mixed using 40mm and down size granite metal and making necessary channel in cement concrete 1:2:4 mix with 20mm anddown size granite metal, finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diameter confirming to IS :12592, total weight length of cover and frame to be not less than 182 kg, fixed in cement concrete M 15 20mm and down size broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. | Each | 104644.7 | 104644.7 | 2.0 | False | None | None | False | None | False | 209289.4 | 0 | 3029952 | 102075 | None | code62 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary - 19/20mm dia 2mm thick ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Mtr | 47.2 | 47.2 | 3000.0 | False | None | None | False | None | False | 141600.0 | 0 | 3029953 | 102075 | None | code63 | Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. - 19/20mm dia 2mm thick ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Mtr | 60.18 | 60.18 | 1500.0 | False | None | None | False | None | False | 90270.0 | 0 | 3029954 | 102075 | None | code64 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary - 25mm dia 2mm thick ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Mtr | 62.54 | 62.54 | 1300.0 | False | None | None | False | None | False | 81302.0 | 0 | 3029955 | 102075 | None | code65 | Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. - 25mm dia 2mm thick ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Mtr | 63.72 | 63.72 | 500.0 | False | None | None | False | None | False | 31860.0 | 0 | 3029956 | 102075 | None | code66 | Supplying and fixing PVC/metal conduit Deep junction box - 19 /20mmdia deep Junction Box ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Each | 50.74 | 50.74 | 30.0 | False | None | None | False | None | False | 1522.2 | 0 | 3029957 | 102075 | None | code67 | Supplying And Fixing Metal Fan Box with Round Hook. ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | No | 100.3 | 100.3 | 30.0 | False | None | None | False | None | False | 3009.0 | 0 | 3029958 | 102075 | None | code68 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP -A. - 1.5 sqmm ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Mtr | 24.19 | 24.19 | 2500.0 | False | None | None | False | None | False | 60475.0 | 0 | 3029959 | 102075 | None | code69 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP -A. - 2.5 sqmm ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Mtr | 37.76 | 37.76 | 2500.0 | False | None | None | False | None | False | 94400.0 | 0 | 3029960 | 102075 | None | code70 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP -A. - 4 sqmm ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Mtr | 53.1 | 53.1 | 600.0 | False | None | None | False | None | False | 31860.0 | 0 | 3029961 | 102075 | None | code71 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 1-3Way ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Each | 112.1 | 112.1 | 15.0 | False | None | None | False | None | False | 1681.5 | 0 | 3029962 | 102075 | None | code72 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 6Way ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Each | 147.5 | 147.5 | 20.0 | False | None | None | False | None | False | 2950.0 | 0 | 3029963 | 102075 | None | code73 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 8Way ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Each | 171.1 | 171.1 | 20.0 | False | None | None | False | None | False | 3422.0 | 0 | 3029964 | 102075 | None | code74 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 10-12Way ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Each | 194.7 | 194.7 | 6.0 | False | None | None | False | None | False | 1168.2 | 0 | 3029965 | 102075 | None | code75 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 1 to 3 Module ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Each | 129.8 | 129.8 | 15.0 | False | None | None | False | None | False | 1947.0 | 0 | 3029966 | 102075 | None | code76 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 6 Module ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Each | 206.5 | 206.5 | 11.0 | False | None | None | False | None | False | 2271.5 | 0 | 3029967 | 102075 | None | code77 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 8 Module ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Each | 236.0 | 236.0 | 20.0 | False | None | None | False | None | False | 4720.0 | 0 | 3029968 | 102075 | None | code78 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 12 Module ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Each | 271.4 | 271.4 | 6.0 | False | None | None | False | None | False | 1628.4 | 0 | 3029969 | 102075 | None | code79 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 GROUP A - 6Amps one way. ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Each | 82.6 | 82.6 | 94.0 | False | None | None | False | None | False | 7764.4 | 0 | 3029970 | 102075 | None | code80 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 GROUP A - 6Amps Two way. ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Each | 112.1 | 112.1 | 4.0 | False | None | None | False | None | False | 448.4 | 0 | 3029971 | 102075 | None | code81 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 GROUP A - 6Amps 3way socket. ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Each | 123.9 | 123.9 | 80.0 | False | None | None | False | None | False | 9912.0 | 0 | 3029972 | 102075 | None | code82 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 GROUP A - Stepped Fan Regulator. ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Each | 342.2 | 342.2 | 25.0 | False | None | None | False | None | False | 8555.0 | 0 | 3029973 | 102075 | None | code83 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 GROUP A - 6Amps Bell push ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Each | 113.28 | 113.28 | 6.0 | False | None | None | False | None | False | 679.68 | 0 | 3029974 | 102075 | None | code84 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 GROUP A - 32Amps DP switch ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Each | 214.76 | 214.76 | 12.0 | False | None | None | False | None | False | 2577.12 | 0 | 3029975 | 102075 | None | code85 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 GROUP A - 6/16Amps universal socket ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Each | 191.16 | 191.16 | 6.0 | False | None | None | False | None | False | 1146.96 | 0 | 3029976 | 102075 | None | code86 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 GROUP A - TV/Telephone socket ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Each | 93.22 | 93.22 | 6.0 | False | None | None | False | None | False | 559.32 | 0 | 3029977 | 102075 | None | code87 | Supplying of LED light fighting 1 x4'- 20/22 w - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. | No | 442.5 | 442.5 | 27.0 | False | None | None | False | None | False | 11947.5 | 0 | 3029978 | 102075 | None | code88 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. - 5-32 Amps DP ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Each | 1072.62 | 1072.62 | 15.0 | False | None | None | False | None | False | 16089.3 | 0 | 3029979 | 102075 | None | code89 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. - 40-63Amps TPN ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Each | 2828.46 | 2828.46 | 2.0 | False | None | None | False | None | False | 5656.92 | 0 | 3029980 | 102075 | None | code90 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.III - Double Door - 12Way TP &N ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Each | 6903.0 | 6903.0 | 1.0 | False | None | None | False | None | False | 6903.0 | 0 | 3029981 | 102075 | None | code91 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 122 mm dia ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | No | 3217.86 | 3217.86 | 2.0 | False | None | None | False | None | False | 6435.72 | 0 | 3029982 | 102075 | None | code92 | Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Each | 2478.0 | 2478.0 | 5.0 | False | None | None | False | None | False | 12390.0 | 0 | 3029983 | 102075 | None | code93 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) - Regular model ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Each | 2466.2 | 2466.2 | 18.0 | False | None | None | False | None | False | 44391.6 | 0 | 3029984 | 102075 | None | code94 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. - On wall / ceiling / Rafter / Girders ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Each | 129.8 | 129.8 | 60.0 | False | None | None | False | None | False | 7788.0 | 0 | 3029985 | 102075 | None | code95 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Each | 177.0 | 177.0 | 25.0 | False | None | None | False | None | False | 4425.0 | 0 | 3029986 | 102075 | None | code96 | Extra length of GI pipe of class B 19mm dia for down rod. ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc., complete as per standard technical specification and directions of the Engineer-in-charge of work. | Mtr | 188.8 | 188.8 | 25.0 | False | None | None | False | None | False | 4720.0 | 0 | 3029987 | 102075 | None | code97 | Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 amps. ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire. ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Each | 767.0 | 767.0 | 6.0 | False | None | None | False | None | False | 4602.0 | 0 | 3029988 | 102075 | None | code98 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A - Short point upto 3Mtr from tapping point to out let via switch box ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Point | 236.0 | 236.0 | 30.0 | False | None | None | False | None | False | 7080.0 | 0 | 3029989 | 102075 | None | code99 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A - Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Point | 324.5 | 324.5 | 30.0 | False | None | None | False | None | False | 9735.0 | 0 | 3029990 | 102075 | None | code100 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A - Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Point | 472.0 | 472.0 | 40.0 | False | None | None | False | None | False | 18880.0 | 0 | 3029991 | 102075 | None | code101 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP -A. - 6 sqmm ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Mtr | 82.6 | 82.6 | 235.0 | False | None | None | False | None | False | 19411.0 | 0 | 3029992 | 102075 | None | code102 | Supplying and mounting 2 Nos. of 2 way 6 amps flush type switches either surface /flush mounted on existing gang box or in 4mm thick plastic sheet and mounted on a flush mounted wooden box and wiring as per IS 1293 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Each | 177.0 | 177.0 | 5.0 | False | None | None | False | None | False | 885.0 | 0 | 3029993 | 102075 | None | code103 | Extra for supplying 4mm thick white plastic plate and covering for junction boxes of size ……mm conduit using necessary machine screws. - 80mm ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | No | 10.62 | 10.62 | 94.0 | False | None | None | False | None | False | 998.28 | 0 | 3029994 | 102075 | None | code104 | Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws - Ding Dong Bell ---- With all lead and lift including cost and conveyance of all materials, labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Each | 259.6 | 259.6 | 5.0 | False | None | None | False | None | False | 1298.0 | 0 | 3029995 | 102075 | None | code105 | Supplying of LT UG cable having aluminium conductor PVC insulated, sheathed, galvanised, steel wire/steel tap armoured cable with PVC outer sheathing 1.1 KV class. | Mtr | 354.0 | 354.0 | 50.0 | False | None | None | False | None | False | 17700.0 | 0 | 3029996 | 102075 | None | code106 | Digging of trench of 0.6m deep x 0.50 mtr wide refiling the trench to the required ground level and consolidating etc., complete. | Mtr | 47.2 | 47.2 | 50.0 | False | None | None | False | None | False | 2360.0 | 0 | 3029997 | 102075 | None | code107 | Supply of LED Streetlight with pressure die cast aluminum housing body with optimal hear sink for better thermal dissipation. Diffuser with Injection moulded and is made of polycarbonate material with high transmission index, delivering superior light-output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminare IK08. Power Factor 0.9 with mains Current should not be greater than 0.1A to 0.7A & Surge Protection-Min 4KV along with Over voltage/Overload, short circuit/ miswiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Over load & short circuit protection ensures reliable operation in spite of problem in output side. Compliance to IS 10322/IEC 60598, LM., 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at sight site location with minimized minimal tools. LED Light fixtures with…W System Power consumption. LED Efficiency130lm/w at 1W & Fixtures Efficiency 80lm/w with nominal CRI 75. Luminaire manufacturer should have in house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. | Each | 21948.0 | 21948.0 | 10.0 | False | None | None | False | None | False | 219480.0 | 0 | 3029998 | 102075 | None | code108 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipments on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proprotion of salt and charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc, is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and checknuts etc, the pipe shall have 16 through holes of 122 mm dia. | Each | 2301.0 | 2301.0 | 4.0 | False | None | None | False | None | False | 9204.0 | 0 | 3029999 | 102075 | None | code109 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C. | Each | 547.52 | 547.52 | 2.0 | False | None | None | False | None | False | 1095.04 | 0 | 3030000 | 102075 | None | code110 | Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic alluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary botls,nuts and washers etc., complete.p-41,i-36 | Rmtr | 2612.52 | 2612.52 | 4.0 | False | None | None | False | None | False | 10450.08 | 0 | 3030001 | 102075 | None | code111 | Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete. | Sqm | 0.51 | 0.51 | 8000.0 | False | None | None | False | None | False | 4080.0 | 0 | 3030002 | 102075 | None | code112 | Specification:- Supplying and fixing of metal clad industrial plugs and sockets. | Each | 433.06 | 433.06 | 10.0 | False | None | None | False | None | False | 4330.6 | 0 | 3030003 | 102075 | None | code113 | SOCKET | Each | 325.68 | 325.68 | 20.0 | False | None | None | False | None | False | 6513.6 | 0 | 3030004 | 102075 | None | code114 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Microprocessed release and Earth Fault as per IS-13947. | Each | 9706.68 | 9706.68 | 2.0 | False | None | None | False | None | False | 19413.36 | 0 |
|