createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1710413239884
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee2040.00
emd192000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose30-03-2024 17:30:00
tenderQueryClose28-03-2024 17:30:00
technicalBidOpen01-04-2024 10:30:00
publishedDate14-03-2024 17:21:36
publishedByPostDUDC_EE_KLB
publishedByUserKPE11288 - SHIVANAGOUDA S PATIL
bidValidityPeriod90
noOfCalls1
preBidMeetingDate22-03-2024 11:30:30
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonSomu Rathod
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9880510192
tenderSupplierListNone
tenderSchedule
createdTs1710413239916
version6
createdDateNone
modifiedDateNone
tenderNumberDMA/2023-24/OW/WORK_INDENT17574
titleDevelopment of Sevalal temple in ward no 4 in wadi town. Construction of Maratha asn sevlal bhavan in wadi town. Constrcution of Toilet for Physically disabled peoples in wadi town.
descriptionDevelopment of Sevalal temple in ward no 4 in wadi town. Construction of Maratha asn sevlal bhavan in wadi town. Constrcution of Toilet for Physically disabled peoples in wadi town.
categoryWORKS
categoryTextWorks
ecv8123341.95
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2188
locationNameDMA District Urban Development Cell Kalaburagi
provisionalAmount9625000.0
groupOverheadTotalNone
fileNumberTMCWadi/CMSTDP4/1
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17104132400000NoneNoneOther WorksConstruction of Maratha and Savita Smaja Bhavan in wadi town.4247483.71
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3070662104725Nonecode01Construction of Maratha samaja bhavan Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. Depth exceeding 1.5m, but not exceeding 3 mCum467.25467.25115.46FalseNoneNoneFalseNoneFalse53948.6850
3070663104725Nonecode02Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum6288.456288.458.61FalseNoneNoneFalseNoneFalse54143.55450
3070664104725Nonecode03Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7170.287170.2814.7FalseNoneNoneFalseNoneFalse105403.1160
3070665104725Nonecode04Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6515.256515.2525.34FalseNoneNoneFalseNoneFalse165096.4350
3070666104725Nonecode05Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6708.456708.459.61FalseNoneNoneFalseNoneFalse64468.20450
3070667104725Nonecode06Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer in charge.Sqm267.75267.7533.684FalseNoneNoneFalseNoneFalse9018.8910
3070668104725Nonecode07Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) 2.3.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11566.811566.85.53FalseNoneNoneFalseNoneFalse63964.4040
3070669104725Nonecode08Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) 2.3.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum10886.410886.42.01FalseNoneNoneFalseNoneFalse21881.6640
3070670104725Nonecode09Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.3110.39FalseNoneNoneFalseNoneFalse30831.9270
3070671104725Nonecode10Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum8376.98376.950.36FalseNoneNoneFalseNoneFalse421860.6840
3070672104725Nonecode11Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super lasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11138.411138.42.23FalseNoneNoneFalseNoneFalse24838.6320
3070673104725Nonecode12Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, uring and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11138.411138.40.4049FalseNoneNoneFalseNoneFalse4509.938160
3070674104725Nonecode13Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) 2.3.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum10886.410886.43.412FalseNoneNoneFalseNoneFalse37144.39680
3070675104725Nonecode14Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super lasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum10442.2510442.2515.2925FalseNoneNoneFalseNoneFalse159688.1081250
3070676104725Nonecode15Supplying, Fitting and Placing TMT Fe 500 & above Reinforcement in Foundation / Substructure Superstructure complete as per Drawing and Technical Specifications.Tonne90754.6590754.652.572FalseNoneNoneFalseNoneFalse233420.95980
3070677104725Nonecode16Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin Charge. Page No.82 Item no.11.26.1 KPWD. Volumn 2 DSR2023 24Kg144.9144.978.37FalseNoneNoneFalseNoneFalse11355.8130
3070678104725Nonecode17Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum144977.7144977.70.1025FalseNoneNoneFalseNoneFalse14860.214250
3070679104725Nonecode18Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer in charge.Sqm333.9333.90.3FalseNoneNoneFalseNoneFalse100.170
3070680104725Nonecode19Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer in charge fixed to frames with 3 nos of 75mm Aluminium hinges with one side prelamSqm2142.02142.01.89FalseNoneNoneFalseNoneFalse4048.380
3070681104725Nonecode20Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.Sqm192.15192.15211.68FalseNoneNoneFalseNoneFalse40674.3120
3070682104725Nonecode21Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, uring complete as per specifications and as per directions of Engineer in charge.Sqm253.05253.05144.3474FalseNoneNoneFalseNoneFalse36527.109570
3070683104725Nonecode22Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per pecifications and as per directions of Engineer in charge.Sqm105.0105.0144.3474FalseNoneNoneFalseNoneFalse15156.4770
3070684104725Nonecode23Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement ortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever equired smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in charge.Sqm389.55389.55236.2107FalseNoneNoneFalseNoneFalse92015.8781850
3070685104725Nonecode24Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per pecifications and as per directions of Engineer in charge.Sqm133.35133.35144.3474FalseNoneNoneFalseNoneFalse19248.725790
3070686104725Nonecode25Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied at the rate 1.43 ltr/10 over and including priming coat of exterior primer applied at the rate 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to move all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer in charge.Sqm186.9186.9236.21FalseNoneNoneFalseNoneFalse44147.6490
3070687104725Nonecode26Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter ncluding preparing the surface even and sand paper smooth, cost of materials, labour complete as per pecifications and as per directions of Engineer in charge.Sqm120.75120.7518.0FalseNoneNoneFalseNoneFalse2173.50
3070688104725Nonecode27Providing & fixing of 3 track x 2 panel sliding windows made out of multi chambered UPVC(Matching to RAL 9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile hrough out the window frame The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm nd mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm 2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm7070.77070.79.0FalseNoneNoneFalseNoneFalse63636.30
3070689104725Nonecode28Providing and fixing in position fully panelled Honne wood shutters for doors with , stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures)Sqm9952.959952.954.2FalseNoneNoneFalseNoneFalse41802.390
3070690104725Nonecode29Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer in charge.Sqm141.75141.758.4FalseNoneNoneFalseNoneFalse1190.70
3070691104725Nonecode30Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry at the rate 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 800x800 mmSqm1351.351351.3563.1973FalseNoneNoneFalseNoneFalse85401.6713550
3070692104725Nonecode31WATER SUPPLY WORKS Of Maratha samja Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work Exposed on wallMtr333.9333.910.0FalseNoneNoneFalseNoneFalse3339.00
3070693104725Nonecode32Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the elected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.Cum508.2508.210.0FalseNoneNoneFalseNoneFalse5082.00
3070694104725Nonecode33Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and ommissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For:Mtr70.3570.3510.0FalseNoneNoneFalseNoneFalse703.50
3070695104725Nonecode34P/F PTMT BIB COCK Providing and fixing PTMT bib cock of approved quality and colour.15mm nominal bore, 86 mm long, weighing not less than 88 gNo167.48167.486.0FalseNoneNoneFalseNoneFalse1004.880
3070696104725Nonecode35P/F PTMT STOPCOCK CONCEALED Concealed stop cock, 15 mm nominal bore, 108 mm long, weighing not less than 108 gmsNo213.06213.062.0FalseNoneNoneFalseNoneFalse426.120
3070697104725Nonecode36P/F BRASS BALL VALVE Providing and fixing Brass full way valve gate with C.I. wheel of Approved quality (screwed end) : ( item no 13..4.1 ) page no 115 PWP. DSR 2023 24No581.94581.942.0FalseNoneNoneFalseNoneFalse1163.880
3070698104725Nonecode37P/F WASH BASIN Providing and fixing wash basin with C.I. brackets, 15 mm PTMT pillar cock, 32 mm PTMT waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm PTMT pillar cock. (item no 14.7B ) page no 125 PWP. DSR 2023 24No2410.82410.81.0FalseNoneNoneFalseNoneFalse2410.80
3070699104725Nonecode3815 mm nominal bore, 125 mm long foam flow, weighing not less than 120 gms13No332.84332.842.0FalseNoneNoneFalseNoneFalse665.680
3070700104725Nonecode39PVC connection pipeNo96.4696.461.0FalseNoneNoneFalseNoneFalse96.460
3070701104725Nonecode40SANITARY WORK WATER CLOSET EUROPEAN TYPE Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : ( item no 14.2 ) page no 123 PWP. DSR 2023 24Pan5079.05079.01.0FalseNoneNoneFalseNoneFalse5079.00
3070702104725Nonecode41WASTE PIPE Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe32 mm dia ( item no 14.28.2.1 ) page no 123 PWP. DSR 2023 24Each97.5297.521.0FalseNoneNoneFalseNoneFalse97.520
3070703104725Nonecode42WASTE PIPE RIGID Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. SEMI RIGID pipe32 mm dia ( item no 14.28.1.1 ) page no 123 PWP. DSR 2023 24Each80.5680.561.0FalseNoneNoneFalseNoneFalse80.560
3070704104725Nonecode43PVC PIPE Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: Pipes of SN4, 110mm dia. ( item no 2.2) page no 134 VOLUME 5 PWP. DSR 2023 24Mtr287.26287.266.0FalseNoneNoneFalseNoneFalse1723.560
3070705104725Nonecode44Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base suooort for tank.Ltr9.459.451000.0FalseNoneNoneFalseNoneFalse9450.00
3070706104725Nonecode45WASTE PIPE RIGID Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe32 mm dia ( item no 14.28.2.1 ) page no 123 PWP. DSR 2023 24Each97.5297.521.0FalseNoneNoneFalseNoneFalse97.520
3070707104725Nonecode46Sinking of Maratha samaj Borewell Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M 15%, b) Above 30 M 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/ is to be deducted for Dry Borewell towards yield test. etc. complete (KPWD SR VOL V for the year 2023 24. I. No. 12.4 P.No. 140 )No5552.05552.01.0FalseNoneNoneFalseNoneFalse5552.00
3070708104725Nonecode47Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 0 to 50 Mtrs (KPWD SR VOL V for the year 2023 24. I. No. 12.1.1 P.No. 132 )Mtr388.5388.550.0FalseNoneNoneFalseNoneFalse19425.00
3070709104725Nonecode48Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 50 to 100 Mtrs (KPWD SR VOL V for the year 2023 24. I. No. 12.1.2 P.No. 132 )Mtr487.2487.250.0FalseNoneNoneFalseNoneFalse24360.00
3070710104725Nonecode49Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 100 to 150 Mtrs (KPWD SR VOL V for the year 2023 24. I. No. 12.1.3 P.No. 132 )Mtr517.65517.6510.0FalseNoneNoneFalseNoneFalse5176.50
3070711104725Nonecode50PVC pipes of 6 Kg/cm2 for 160mm (KPWD SR VOL V for the year 2023 24. Sl No. 649 P.No. A44 )Mtr441.0441.06.0FalseNoneNoneFalseNoneFalse2646.00
3070712104725Nonecode51PVC pipes of 6 Kg/cm2 for 110mm (KPWD SR VOL V for the year 2023 24. Sl No. 647 P.No. A44 )Mtr267.75267.75110.0FalseNoneNoneFalseNoneFalse29452.50
3070713104725Nonecode52Providing and laying at site of work MS casing caps as per IS 1239 (part II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part II) 1982 with all Amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in Charge ( (PWD UGD and water supply SR 2023 24 Volume V Item no.12.34 page no.143)Mtr172.2172.21.0FalseNoneNoneFalseNoneFalse172.20
3070714104725Nonecode53Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034 2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest ammendments 1.50 HP/1.1KW 20 STG (PWD UGD and water supply SR 2023 24 Volume V Item no.13.7.7 page no.150)No19128.919128.91.0FalseNoneNoneFalseNoneFalse19128.90
3070715104725Nonecode54Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. (PWD UGD and water supply SR 2023 24 Volume V Item no.13.31 page no.155)Mtr42.042.0110.0FalseNoneNoneFalseNoneFalse4620.00
3070716104725Nonecode55Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. (PWD UGD and water supply SR 2023 24 Volume V Item no.13.32 page no.156)Job6825.06825.01.0FalseNoneNoneFalseNoneFalse6825.00
3070717104725Nonecode56Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694 1990 with ISI Mark and as per its latest amendments. 1x3x6 Sqm. (PWD UGD and water supply SR 2023 24 Volume V Item no.13.22.4 page no.154)Mtr194.25194.25115.0FalseNoneNoneFalseNoneFalse22338.750
3070718104725Nonecode57Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984 2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0 (PWD UGD and water supply SR 2023 24 Volume V Item no.9.1.1 page no.95)Mtr198.45198.45105.0FalseNoneNoneFalseNoneFalse20837.250
3070719104725Nonecode58Supply and delivery at site of brand new best make non return valve as per IS 778/1984 with ISI Mark and as per its latest amendments (PWD UGD and water supply SR 2023 24 Volume V Item no.13.25.2 page no.154)No1627.51627.51.0FalseNoneNoneFalseNoneFalse1627.50
3070720104725Nonecode59Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL Direct Online Starter 2) S D Star Delta Starter etc. complete.Upto 3 HP pumps (PWD UGD and water supply SR 2023 24 Volume V Item no.13.24.1 page no.155)Each7875.07875.01.0FalseNoneNoneFalseNoneFalse7875.00
3070721104725Nonecode60Labour charges for erection of outdoor type panel board and meter board units with all necessary materials and labour, tools and equipments including providing cement concrete foundation bed etc., complete as per specification, with testing of as per instructions of engineer incharge of work. (PWD UGD and water supply SR 2023 24 Volume V Item no.13.34 page no.156)Job1522.51522.51.0FalseNoneNoneFalseNoneFalse1522.50
3070722104725Nonecode61Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPTCL authorities and erection, electrification and commissioning of the same at the location of respective pump sets. (PWD UGD and water supply SR 2023 24 Volume V Item no.13.25 page no.155)Kvar577.5577.51.0FalseNoneNoneFalseNoneFalse577.50
3070723104725Nonecode62Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box. (PWD UGD and water supply SR 2023 24 Volume V Item no.13.26 page no.155)No1207.51207.51.0FalseNoneNoneFalseNoneFalse1207.50
3070724104725Nonecode63Labour charges for providing connection using insulated sheathed steel wire cable as per IS 1554/ 1988 with latest amendments from KPTCL pole to meter board unit, with all necessary materials ,tools and equipments,as per specificationswith testing of as per instructions of engineer incharge of work. 3.5 x 16 sqmm (PWD UGD and water supply SR 2023 24 Volume V Item no.13.35.2 page no.156)No168.0168.01.0FalseNoneNoneFalseNoneFalse168.00
3070725104725Nonecode64ELECTRICAL WORK Construction of Savitha samaj Bhavan Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and leadCum754.95754.954.675FalseNoneNoneFalseNoneFalse3529.391250
3070726104725Nonecode65PWD SR 2023 24 V III Item No. 2.11 (ii) A, Page No. 08Cum189.0189.060.2174FalseNoneNoneFalseNoneFalse11381.08860
3070727104725Nonecode66PWD SR 2023 24 V III Item No. 2.13 B, Page No. 09Sqm2109.452109.451.9925FalseNoneNoneFalseNoneFalse4203.0791250
3070728104725Nonecode67Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. Depth exceeding 1.5m, but not exceeding 3 mCum467.25467.25115.46FalseNoneNoneFalseNoneFalse53948.6850
3070729104725Nonecode68Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum6288.456288.458.61FalseNoneNoneFalseNoneFalse54143.55450
3070730104725Nonecode69Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7170.287170.2814.7FalseNoneNoneFalseNoneFalse105403.1160
3070731104725Nonecode70Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6515.256515.2525.3381FalseNoneNoneFalseNoneFalse165084.0560250
3070732104725Nonecode71Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6708.456708.459.608FalseNoneNoneFalseNoneFalse64454.78760
3070733104725Nonecode72Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer in charge.Sqm267.75267.7533.684FalseNoneNoneFalseNoneFalse9018.8910
3070734104725Nonecode73Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) 2.3.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11566.811566.85.5269FalseNoneNoneFalseNoneFalse63928.546920
3070735104725Nonecode74Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) 2.3.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum10886.410886.42.006FalseNoneNoneFalseNoneFalse21838.11840
3070736104725Nonecode75Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.3110.393FalseNoneNoneFalseNoneFalse30832.76490
3070737104725Nonecode76Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum8376.98376.950.3591FalseNoneNoneFalseNoneFalse421853.144790
3070738104725Nonecode77Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super lasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11138.411138.42.23FalseNoneNoneFalseNoneFalse24838.6320
3070739104725Nonecode78Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, uring and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11138.411138.40.404FalseNoneNoneFalseNoneFalse4499.91360
3070740104725Nonecode79Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) 2.3.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum10206.010206.03.412FalseNoneNoneFalseNoneFalse34822.8720
3070741104725Nonecode80Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super lasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum10442.2510442.2515.2925FalseNoneNoneFalseNoneFalse159688.1081250
3070742104725Nonecode81Supplying, Fitting and Placing TMT Fe 500 & above Reinforcement in Foundation / Substructure Superstructure complete as per Drawing and Technical Specifications.Tonne90754.6590754.652.572FalseNoneNoneFalseNoneFalse233420.95980
3070743104725Nonecode82Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum144977.7144977.70.1025FalseNoneNoneFalseNoneFalse14860.214250
3070744104725Nonecode83Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer in charge.Sqm333.9333.90.3FalseNoneNoneFalseNoneFalse100.170
3070745104725Nonecode84Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer in charge fixed to frames with 3 nos of 75mm Aluminium hinges with one side prelamSqm2142.02142.01.89FalseNoneNoneFalseNoneFalse4048.380
3070746104725Nonecode85Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.Sqm192.15192.15211.68FalseNoneNoneFalseNoneFalse40674.3120
3070747104725Nonecode86Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin Charge. Page No.82 Item no.11.26.1 KPWD. Volumn 2 DSR2023 24Kg144.9144.978.37FalseNoneNoneFalseNoneFalse11355.8130
3070748104725Nonecode87Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, uring complete as per specifications and as per directions of Engineer in charge.Sqm253.05253.05144.3474FalseNoneNoneFalseNoneFalse36527.109570
3070749104725Nonecode88Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per pecifications and as per directions of Engineer in charge.Sqm105.0105.0144.3474FalseNoneNoneFalseNoneFalse15156.4770
3070750104725Nonecode89Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement ortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever equired smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in charge.Sqm389.55389.55236.21FalseNoneNoneFalseNoneFalse92015.60550
3070751104725Nonecode90Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per pecifications and as per directions of Engineer in charge.Sqm133.35133.35144.3474FalseNoneNoneFalseNoneFalse19248.725790
3070752104725Nonecode91Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied at the rate 1.43 ltr/10 m² over and including priming coat of exterior primer applied at the rate 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to move all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer in charge.Sqm186.9186.9236.21FalseNoneNoneFalseNoneFalse44147.6490
3070753104725Nonecode92Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter ncluding preparing the surface even and sand paper smooth, cost of materials, labour complete as per pecifications and as per directions of Engineer in charge.Sqm120.75120.7518.0FalseNoneNoneFalseNoneFalse2173.50
3070754104725Nonecode93Providing & fixing of 3 track x 2 panel sliding windows made out of multi chambered UPVC(Matching to RAL 9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile hrough out the window frame The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm nd mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm 2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm7070.77070.79.0FalseNoneNoneFalseNoneFalse63636.30
3070755104725Nonecode94Providing and fixing in position fully panelled Honne wood shutters for doors with , stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures)Sqm7439.257439.254.2FalseNoneNoneFalseNoneFalse31244.850
3070756104725Nonecode95Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer in charge.Sqm141.75141.758.4FalseNoneNoneFalseNoneFalse1190.70
3070757104725Nonecode96Providing and laying vitrified floor tiles with thickness 9 10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry at the rate 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mmSqm1136.11136.163.19FalseNoneNoneFalseNoneFalse71790.1590
3070758104725Nonecode97WATER SUPPLY WORKS Of Savitha samja Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work Exposed on wallMtr333.9333.910.0FalseNoneNoneFalseNoneFalse3339.00
3070759104725Nonecode98Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the elected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.Cum508.2508.210.0FalseNoneNoneFalseNoneFalse5082.00
3070760104725Nonecode99Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and ommissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For:Mtr70.3570.3510.0FalseNoneNoneFalseNoneFalse703.50
3070761104725Nonecode100P/F PTMT BIB COCK Providing and fixing PTMT bib cock of approved quality and colour.15mm nominal bore, 86 mm long, weighing not less than 88 gNo167.48167.486.0FalseNoneNoneFalseNoneFalse1004.880
3070762104725Nonecode101P/F PTMT STOPCOCK CONCEALED Concealed stop cock, 15 mm nominal bore, 108 mm long, weighing not less than 108 gmsNo213.06213.062.0FalseNoneNoneFalseNoneFalse426.120
3070763104725Nonecode102P/F BRASS BALL VALVE Providing and fixing Brass full way valve gate with C.I. wheel of Approved quality (screwed end) : ( item no 13..4.1 ) page no 115 PWP. DSR 2023 24No581.94581.942.0FalseNoneNoneFalseNoneFalse1163.880
3070764104725Nonecode103P/F WASH BASIN Providing and fixing wash basin with C.I. brackets, 15 mm PTMT pillar cock, 32 mm PTMT waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm PTMT pillar cock. (item no 14.7B ) page no 125 PWP. DSR 2023 24No2410.82410.81.0FalseNoneNoneFalseNoneFalse2410.80
3070765104725Nonecode10415 mm nominal bore, 125 mm long foam flow, weighing not less than 120 gms13No332.84332.842.0FalseNoneNoneFalseNoneFalse665.680
3070766104725Nonecode105PVC connection pipeNo96.4696.461.0FalseNoneNoneFalseNoneFalse96.460
3070767104725Nonecode106SANITARY WORK WATER CLOSET EUROPEAN TYPE Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : ( item no 14.2 ) page no 123 PWP. DSR 2023 24Pan5079.05079.01.0FalseNoneNoneFalseNoneFalse5079.00
3070768104725Nonecode107WASTE PIPE Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe32 mm dia ( item no 14.28.2.1 ) page no 123 PWP. DSR 2023 24Each97.5297.521.0FalseNoneNoneFalseNoneFalse97.520
3070769104725Nonecode108WASTE PIPE RIGID Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. SEMI RIGID pipe32 mm dia ( item no 14.28.1.1 ) page no 123 PWP. DSR 2023 24Each80.5680.561.0FalseNoneNoneFalseNoneFalse80.560
3070770104725Nonecode109PVC PIPE Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: Pipes of SN4, 110mm dia. ( item no 2.2) page no 134 VOLUME 5 PWP. DSR 2023 24Mtr287.26287.266.0FalseNoneNoneFalseNoneFalse1723.560
3070771104725Nonecode110Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base suooort for tank.Ltr9.459.451000.0FalseNoneNoneFalseNoneFalse9450.00
3070772104725Nonecode111WASTE PIPE RIGID Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe32 mm dia ( item no 14.28.2.1 ) page no 123 PWP. DSR 2023 24Each97.5297.521.0FalseNoneNoneFalseNoneFalse97.520
3070773104725Nonecode112Sinking of Borewell at savitha samaj Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M 15%, b) Above 30 M 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/ is to be deducted for Dry Borewell towards yield test. etc. complete (KPWD SR VOL V for the year 2023 24. I. No. 12.4 P.No. 140 )No5552.05552.01.0FalseNoneNoneFalseNoneFalse5552.00
3070774104725Nonecode113Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 0 to 50 Mtrs (KPWD SR VOL V for the year 2023 24. I. No. 12.1.1 P.No. 132 )Mtr388.5388.550.0FalseNoneNoneFalseNoneFalse19425.00
3070775104725Nonecode114Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 50 to 100 Mtrs (KPWD SR VOL V for the year 2023 24. I. No. 12.1.2 P.No. 132 )Mtr487.2487.250.0FalseNoneNoneFalseNoneFalse24360.00
3070776104725Nonecode115Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 100 to 150 Mtrs (KPWD SR VOL V for the year 2023 24. I. No. 12.1.3 P.No. 132 )Mtr517.65517.6510.0FalseNoneNoneFalseNoneFalse5176.50
3070777104725Nonecode116PVC pipes of 6 Kg/cm2 for 160mm (KPWD SR VOL V for the year 2023 24. Sl No. 649 P.No. A44 )Mtr441.0441.06.0FalseNoneNoneFalseNoneFalse2646.00
3070778104725Nonecode117PVC pipes of 6 Kg/cm2 for 110mm (KPWD SR VOL V for the year 2023 24. Sl No. 647 P.No. A44 )Mtr267.75267.75110.0FalseNoneNoneFalseNoneFalse29452.50
3070779104725Nonecode118Providing and laying at site of work MS casing caps as per IS 1239 (part II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part II) 1982 with all Amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in Charge ( (PWD UGD and water supply SR 2023 24 Volume V Item no.12.34 page no.143)Mtr172.2172.21.0FalseNoneNoneFalseNoneFalse172.20
3070780104725Nonecode119Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034 2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest ammendments 1.50 HP/1.1KW 20 STG (PWD UGD and water supply SR 2023 24 Volume V Item no.13.7.7 page no.150)No19128.919128.91.0FalseNoneNoneFalseNoneFalse19128.90
3070781104725Nonecode120Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. (PWD UGD and water supply SR 2023 24 Volume V Item no.13.31 page no.155)Mtr42.042.0110.0FalseNoneNoneFalseNoneFalse4620.00
3070782104725Nonecode121Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. (PWD UGD and water supply SR 2023 24 Volume V Item no.13.32 page no.156)Job6825.06825.01.0FalseNoneNoneFalseNoneFalse6825.00
3070783104725Nonecode122Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694 1990 with ISI Mark and as per its latest amendments. 1x3x6 Sqm. (PWD UGD and water supply SR 2023 24 Volume V Item no.13.22.4 page no.154)Mtr194.25194.25115.0FalseNoneNoneFalseNoneFalse22338.750
3070784104725Nonecode123Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984 2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0 (PWD UGD and water supply SR 2023 24 Volume V Item no.9.1.1 page no.95)Mtr198.45198.45105.0FalseNoneNoneFalseNoneFalse20837.250
3070785104725Nonecode124Supply and delivery at site of brand new best make non return valve as per IS 778/1984 with ISI Mark and as per its latest amendments (PWD UGD and water supply SR 2023 24 Volume V Item no.13.25.2 page no.154)No1627.51627.51.0FalseNoneNoneFalseNoneFalse1627.50
3070786104725Nonecode125Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL Direct Online Starter 2) S D Star Delta Starter etc. complete.Upto 3 HP pumps (PWD UGD and water supply SR 2023 24 Volume V Item no.13.24.1 page no.155)Each7875.07875.01.0FalseNoneNoneFalseNoneFalse7875.00
3070787104725Nonecode126Labour charges for erection of outdoor type panel board and meter board units with all necessary materials and labour, tools and equipments including providing cement concrete foundation bed etc., complete as per specification, with testing of as per instructions of engineer incharge of work. (PWD UGD and water supply SR 2023 24 Volume V Item no.13.34 page no.156)Job1522.51522.51.0FalseNoneNoneFalseNoneFalse1522.50
3070788104725Nonecode127Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPTCL authorities and erection, electrification and commissioning of the same at the location of respective pump sets. (PWD UGD and water supply SR 2023 24 Volume V Item no.13.25 page no.155)Kvar577.5577.51.0FalseNoneNoneFalseNoneFalse577.50
3070789104725Nonecode128Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box. (PWD UGD and water supply SR 2023 24 Volume V Item no.13.26 page no.155)No1207.51207.51.0FalseNoneNoneFalseNoneFalse1207.50
3070790104725Nonecode129Labour charges for providing connection using insulated sheathed steel wire cable as per IS 1554/ 1988 with latest amendments from KPTCL pole to meter board unit, with all necessary materials ,tools and equipments,as per specificationswith testing of as per instructions of engineer incharge of work. 3.5 x 16 sqmm (PWD UGD and water supply SR 2023 24 Volume V Item no.13.35.2 page no.156)No168.0168.01.0FalseNoneNoneFalseNoneFalse168.00
17104132400000NoneNoneOther WorksConstrcution of Toilet for Physically disabled peoples in wadi town.1761941.9
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3070791104726Nonecode01Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.(ii) By Mechanical Means using DozerB In area of thorny jungleha508.2508.20.5FalseNoneNoneFalseNoneFalse254.10
3070792104726Nonecode02Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, trutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.Cum95.5595.558.64FalseNoneNoneFalseNoneFalse825.5520
3070793104726Nonecode03Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.Depth exceeding 1.5m, but not exceeding 3 mCum467.25467.2550.76FalseNoneNoneFalseNoneFalse23717.610
3070794104726Nonecode04Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum6288.456288.456.012FalseNoneNoneFalseNoneFalse37806.16140
3070795104726Nonecode05Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6971.116971.114.788FalseNoneNoneFalseNoneFalse33377.674680
3070796104726Nonecode06Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) 2.3.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11566.811566.81.5264FalseNoneNoneFalseNoneFalse17655.563520
3070797104726Nonecode07Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) 2.3.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum10206.010206.01.584FalseNoneNoneFalseNoneFalse16166.3040
3070798104726Nonecode08Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6708.456708.459.504FalseNoneNoneFalseNoneFalse63757.10880
3070799104726Nonecode09Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge.Sqm267.75267.7515.84FalseNoneNoneFalseNoneFalse4241.160
3070800104726Nonecode10Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.344.62FalseNoneNoneFalseNoneFalse12462.3660
3070801104726Nonecode11Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1375.51375.544.28FalseNoneNoneFalseNoneFalse60907.140
3070802104726Nonecode12Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having lock density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1159.21159.218.9599FalseNoneNoneFalseNoneFalse21978.316080
3070803104726Nonecode13Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregatesCum6527.856527.850.1FalseNoneNoneFalseNoneFalse652.7850
3070804104726Nonecode14Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super lasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11138.411138.41.944FalseNoneNoneFalseNoneFalse21653.04960
3070805104726Nonecode15Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super lasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum10442.2510442.253.06FalseNoneNoneFalseNoneFalse31953.2850
3070806104726Nonecode16Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm253.05253.0524.48FalseNoneNoneFalseNoneFalse6194.6640
3070807104726Nonecode17Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum10442.2510442.251.152FalseNoneNoneFalseNoneFalse12029.4720
3070808104726Nonecode18Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400per rcentage and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per pecification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm857.85857.8521.6FalseNoneNoneFalseNoneFalse18529.560
3070809104726Nonecode19Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum103755.75103755.750.782FalseNoneNoneFalseNoneFalse81136.99650
3070810104726Nonecode20Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures )Sqm7816.27816.28.82FalseNoneNoneFalseNoneFalse68938.8840
3070811104726Nonecode21Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.Kg192.15192.1556.7FalseNoneNoneFalseNoneFalse10894.9050
3070812104726Nonecode22Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement ortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever equired smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm389.55389.5549.86FalseNoneNoneFalseNoneFalse19422.9630
3070813104726Nonecode23Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, uring complete as per specifications and as per directions of Engineer-in-charge.Sqm253.05253.0580.16FalseNoneNoneFalseNoneFalse20284.4880
3070814104726Nonecode24Providing and laying red oxide flooring 40 mm thick, with an under layer of 30mm thick M-15 cement concrete and top layer of 10mm thick plaster with 1:3 cement mortar mixed with red oxide finished with floating coat of neat cement mixed with red oxide ( mix of same proportion ) , including cost of materials, labour, curing, complete as per specifications.Sqm825.3825.316.64FalseNoneNoneFalseNoneFalse13732.9920
3070815104726Nonecode25Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement ortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete.Sqm1161.31161.365.76FalseNoneNoneFalseNoneFalse76367.0880
3070816104726Nonecode26Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per pecifications and as per directions of Engineer in charge.Sqm105.0105.074.34FalseNoneNoneFalseNoneFalse7805.70
3070817104726Nonecode27Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per pecifications and as per directions of Engineer-in-charge.Sqm133.35133.3549.86FalseNoneNoneFalseNoneFalse6648.8310
3070818104726Nonecode28Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to move all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm186.9186.949.86FalseNoneNoneFalseNoneFalse9318.8340
3070819104726Nonecode29Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineerin- charge.Sqm27.327.349.86FalseNoneNoneFalseNoneFalse1361.1780
3070820104726Nonecode30Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter ncluding preparing the surface even and sand paper smooth, cost of materials, labour complete as per pecifications and as per directions of Engineer-in-charge.Sqm120.75120.755.4FalseNoneNoneFalseNoneFalse652.050
3070821104726Nonecode31Supplying, Fitting and Placing TMT Fe 500 & above Reinforcement in Foundation / Substructure Superstructure complete as per Drawing and Technical Specifications.Tonne90754.6590754.651.542FalseNoneNoneFalseNoneFalse139943.67030
3070822104726Nonecode32Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other ppurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) 2.1.4 Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregatesCum6527.856527.852.376FalseNoneNoneFalseNoneFalse15510.17160
3070823104726Nonecode33Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the ngineerin- Charge.)Kg192.15192.15423.36FalseNoneNoneFalseNoneFalse81348.6240
3070824104726Nonecode34Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-chargeSqm333.9333.921.42FalseNoneNoneFalseNoneFalse7152.1380
3070825104726Nonecode35Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per anufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.12.55.2 -do- with one side prelamCum2142.02142.021.42FalseNoneNoneFalseNoneFalse45881.640
3070826104726Nonecode36Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameterMtr305.55305.5546.0FalseNoneNoneFalseNoneFalse14055.30
3070827104726Nonecode37Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, if c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipesMtr397.95397.9540.0FalseNoneNoneFalseNoneFalse15918.00
3070828104726Nonecode38Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, if c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipesMtr584.85584.8540.0FalseNoneNoneFalseNoneFalse23394.00
3070829104726Nonecode39Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required 14.2.1 W.C. pan with ISI marked white solid plastic seat and lidEach5079.95079.96.0FalseNoneNoneFalseNoneFalse30479.40
3070830104726Nonecode40Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cisternEach4676.74676.74.0FalseNoneNoneFalseNoneFalse18706.80
3070831104726Nonecode41Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 14.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar tapsEach3236.13236.14.0FalseNoneNoneFalseNoneFalse12944.40
3070832104726Nonecode42Providing and fixing brass stop cock of approved quality : 13.3.2 20 mm nominal boreEach320.25320.258.0FalseNoneNoneFalseNoneFalse2562.00
3070833104726Nonecode43Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 13.5.3 25 mm nominal boreEach348.6348.64.0FalseNoneNoneFalseNoneFalse1394.40
3070834104726Nonecode44Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base suooort for tank.Ltr9.459.452000.0FalseNoneNoneFalseNoneFalse18900.00
3070835104726Nonecode45Providing and fixing unplasticised PVC connection pipe with brass unions : 45 cm length 13.8.2.1 15 mm nominal boreNo95.5595.554.0FalseNoneNoneFalseNoneFalse382.20
3070836104726Nonecode46Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.No1281.01281.04.0FalseNoneNoneFalseNoneFalse5124.00
3070837104726Nonecode47Providing and fixing 100 mm sand cast Iron grating for gully trap.Each49.3549.354.0FalseNoneNoneFalseNoneFalse197.40
3070838104726Nonecode48Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth Page No.6 Item No. 1.5.1 KPWD. Volumn -1 DSR 2023-24Cum313.95313.95434.43FalseNoneNoneFalseNoneFalse136389.29850
3070839104726Nonecode49Providing Brick work with common burnt clay machine moulded perforated bricks of class designation 3.5 in superstructure above plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) With Non modular bricks including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum8367.458367.452.484FalseNoneNoneFalseNoneFalse20784.74580
3070840104726Nonecode50Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm404.25404.2537.92FalseNoneNoneFalseNoneFalse15329.160
3070841104726Nonecode51Providing and laying 100mm thick pre-cast cover slabs over drains & Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. itm.no 17.12 Page No.152 KPWD. Volumn -2 DSR 2023-24Sqm974.4974.44.1334FalseNoneNoneFalseNoneFalse4027.584960
3070842104726Nonecode52Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe32 mm dia ( item no 14.28.2.1 ) page no 123 PWP. DSR 2023-24Each96.696.64.0FalseNoneNoneFalseNoneFalse386.40
3070843104726Nonecode53Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15per rcentage, b) Above 30 M - 30per rcentage (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. etc. complete (KPWD SR VOL V for the year 2023-24. I. No. 12.4 P.No. 140 )No5552.45552.42.0FalseNoneNoneFalseNoneFalse11104.80
3070844104726Nonecode54Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10per rcentage for every 50m depth) Borewell depth of 0 to 50 Mtrs (KPWD SR VOL V for the year 2023-24. I. No. 12.1.1 P.No. 132 )Mtr388.5388.5100.0FalseNoneNoneFalseNoneFalse38850.00
3070845104726Nonecode55Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10per rcentage for every 50m depth) Borewell depth of 50 to 100 Mtrs (KPWD SR VOL V for the year 2023-24. I. No. 12.1.2 P.No. 132 )Mtr487.2487.2100.0FalseNoneNoneFalseNoneFalse48720.00
3070846104726Nonecode56Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10per rcentage for every 50m depth) Borewell depth of 100 to 150 Mtrs (KPWD SR VOL V for the year 2023-24. I. No. 12.1.3 P.No. 132 )Mtr517.65517.6520.0FalseNoneNoneFalseNoneFalse10353.00
3070847104726Nonecode57PVC pipes of 6 Kg/cm2 for 160mm (KPWD SR VOL V for the year 2023-24. Sl No. 649 P.No. A44 )Mtr441.0441.012.0FalseNoneNoneFalseNoneFalse5292.00
3070848104726Nonecode58PVC pipes of 6 Kg/cm2 for 110mm (KPWD SR VOL V for the year 2023-24. Sl No. 647 P.No. A44 )Mtr267.75267.75220.0FalseNoneNoneFalseNoneFalse58905.00
3070849104726Nonecode59Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all Amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in Charge ( (PWD UGD and water supply SR 2023-24 Volume - V Item no.12.34 page no.143)Mtr172.2172.22.0FalseNoneNoneFalseNoneFalse344.40
3070850104726Nonecode60Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest ammendments 1.50 HP/1.1KW 20 STG (PWD UGD and water supply SR 2023-24 Volume - V Item no.13.7.7 page no.150)No19128.919128.92.0FalseNoneNoneFalseNoneFalse38257.80
3070851104726Nonecode61Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. (PWD UGD and water supply SR 2023-24 Volume - V Item no.13.31 page no.155)Mtr42.042.0220.0FalseNoneNoneFalseNoneFalse9240.00
3070852104726Nonecode62Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. (PWD UGD and water supply SR 2023-24 Volume - V Item no.13.32 page no.156)Job6825.06825.02.0FalseNoneNoneFalseNoneFalse13650.00
3070853104726Nonecode63Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x6 Sqm. (PWD UGD and water supply SR 2023-24 Volume - V Item no.13.22.4 page no.154)Mtr194.25194.25230.0FalseNoneNoneFalseNoneFalse44677.50
3070854104726Nonecode64Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0 (PWD UGD and water supply SR 2023-24 Volume - V Item no.9.1.1 page no.95)Mtr198.45198.45210.0FalseNoneNoneFalseNoneFalse41674.50
3070855104726Nonecode65Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments (PWD UGD and water supply SR 2023-24 Volume - V Item no.13.25.2 page no.154)No1627.51627.52.0FalseNoneNoneFalseNoneFalse3255.00
3070856104726Nonecode66Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete.Upto 3 HP pumps (PWD UGD and water supply SR 2023-24 Volume - V Item no.13.24.1 page no.155)Each7875.07875.02.0FalseNoneNoneFalseNoneFalse15750.00
3070857104726Nonecode67Labour charges for erection of outdoor type panel board and meter board units with all necessary materials and labour, tools and equipments including providing cement concrete foundation bed etc., complete as per specification, with testing of as per instructions of engineer incharge of work. (PWD UGD and water supply SR 2023-24 Volume - V Item no.13.34 page no.156)Job1522.51522.52.0FalseNoneNoneFalseNoneFalse3045.00
3070858104726Nonecode68Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPTCL authorities and erection, electrification and commissioning of the same at the location of respective pump sets. (PWD UGD and water supply SR 2023-24 Volume - V Item no.13.25 page no.155)Kvar577.5577.52.0FalseNoneNoneFalseNoneFalse1155.00
3070859104726Nonecode69Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box. (PWD UGD and water supply SR 2023-24 Volume - V Item no.13.26 page no.155)No1207.51207.52.0FalseNoneNoneFalseNoneFalse2415.00
3070860104726Nonecode70Labour charges for providing connection using insulated sheathed steel wire cable as per IS 1554/ 1988 with latest amendments from KPTCL pole to meter board unit, with all necessary materials ,tools and equipments,as per specificationswith testing of as per instructions of engineer incharge of work. 3.5 x 16 sqmm (PWD UGD and water supply SR 2023-24 Volume - V Item no.13.35.2 page no.156)No168.0168.02.0FalseNoneNoneFalseNoneFalse336.00
3070861104726Nonecode71Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19/20mm dia 2mm thick.Mtr69.069.060.0FalseNoneNoneFalseNoneFalse4140.00
3070862104726Nonecode72Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25mm dia 2mm thick.Mtr81.081.060.0FalseNoneNoneFalseNoneFalse4860.00
3070863104726Nonecode73Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 32mm dia 2.5mm thick.Mtr106.0106.060.0FalseNoneNoneFalseNoneFalse6360.00
3070864104726Nonecode74Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19/20mm dia 2mm thickMtr68.068.020.0FalseNoneNoneFalseNoneFalse1360.00
3070865104726Nonecode75Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25mm dia 2mm thickMtr79.079.060.0FalseNoneNoneFalseNoneFalse4740.00
3070866104726Nonecode76Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary 32mm dia 2.5mm thickMtr99.099.060.0FalseNoneNoneFalseNoneFalse5940.00
3070867104726Nonecode77Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, screws at an interval of 300mm …. etc. as required.25mmMtr35.035.050.0FalseNoneNoneFalseNoneFalse1750.00
3070868104726Nonecode78Supplying And Fixing Metal Fan Box with Round HookNo160.0160.04.0FalseNoneNoneFalseNoneFalse640.00
3070869104726Nonecode79Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.3.2 1.5 mm2Mtr26.026.060.0FalseNoneNoneFalseNoneFalse1560.00
3070870104726Nonecode80Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.3.3 2.5 mm2Mtr42.042.060.0FalseNoneNoneFalseNoneFalse2520.00
3070871104726Nonecode81Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.3.4 4 mm2Mtr63.063.060.0FalseNoneNoneFalseNoneFalse3780.00
3070872104726Nonecode82Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.3.5 6 mm2Mtr92.092.060.0FalseNoneNoneFalseNoneFalse5520.00
3070873104726Nonecode83Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 2.3.6 10 mm2Mtr167.0167.060.0FalseNoneNoneFalseNoneFalse10020.00
3070874104726Nonecode84Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.1 1-3 WayEach138.0138.02.0FalseNoneNoneFalseNoneFalse276.00
3070875104726Nonecode85Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.3 6 WayEach177.0177.02.0FalseNoneNoneFalseNoneFalse354.00
3070876104726Nonecode86Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.4 8 WayEach220.0220.02.0FalseNoneNoneFalseNoneFalse440.00
3070877104726Nonecode87Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.5 10-12 WayEach261.0261.02.0FalseNoneNoneFalseNoneFalse522.00
3070878104726Nonecode88Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3.5.1 1 to 3 ModuleEach127.0127.02.0FalseNoneNoneFalseNoneFalse254.00
3070879104726Nonecode89Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3.5.3 6 ModuleEach175.0175.02.0FalseNoneNoneFalseNoneFalse350.00
3070880104726Nonecode90Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3.5.4 8 ModuleEach234.0234.02.0FalseNoneNoneFalseNoneFalse468.00
3070881104726Nonecode91Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3.5.5 10-12 Module Each284.0284.02.0FalseNoneNoneFalseNoneFalse568.00
3070882104726Nonecode92Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.1 6A One Way Switch Each102.0102.02.0FalseNoneNoneFalseNoneFalse204.00
3070883104726Nonecode93Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.3 6A Three Way socket Each171.0171.02.0FalseNoneNoneFalseNoneFalse342.00
3070884104726Nonecode94Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.8 16A One Way Switch Each177.0177.02.0FalseNoneNoneFalseNoneFalse354.00
3070885104726Nonecode95Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. II - Double Door 5.18.6 4 Way SP & N Each1368.01368.02.0FalseNoneNoneFalseNoneFalse2736.00
3070886104726Nonecode96Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. II - Double Door 5.18.7 6 Way SP & N Each1102.01102.02.0FalseNoneNoneFalseNoneFalse2204.00
3070887104726Nonecode97Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 5.17.1 6-32 A SP Each415.0415.02.0FalseNoneNoneFalseNoneFalse830.00
3070888104726Nonecode98Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 5.17.7 6-32 A TPN Each1717.01717.02.0FalseNoneNoneFalseNoneFalse3434.00
3070889104726Nonecode99Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB ). The entire plug and socket shall be mounted in a thermoplastic / powder coated metal box & wired Completely. SP & N SP & N 5.45.2 20 A Each971.0971.02.0FalseNoneNoneFalseNoneFalse1942.00
3070890104726Nonecode100Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB ). The entire plug and socket shall be mounted in a thermoplastic / powder coated metal box & wired Completely. SP & N TP & N 5.45.3 20 A Each1340.01340.04.0FalseNoneNoneFalseNoneFalse5360.00
3070891104726Nonecode1011.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 32.11 50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm) Km178973.0178973.00.04FalseNoneNoneFalseNoneFalse7158.920
3070892104726Nonecode102Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 1.06 35 to 95 SqmmKm31139.031139.00.1FalseNoneNoneFalseNoneFalse3113.90
3070893104726Nonecode103Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. 29.03 In Hard Soil Cum389.0389.014.0FalseNoneNoneFalseNoneFalse5446.00
3070894104726Nonecode104Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cm. Thickness including depositing of the surplus earth with a lead of 200 Mtr Cum58.058.014.0FalseNoneNoneFalseNoneFalse812.00
3070895104726Nonecode105LED Indoor Supplying of .feet -PVC Batten with integrated LED tube . W with high quality diffuser with Life of 25000 burning hours & 70per rcentage lumen maintenance with CRI Greater then 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater then0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. 11.3.3 LED light fitting 1 x 4' - 36/40 W Each1269.01269.04.0FalseNoneNoneFalseNoneFalse5076.00
3070896104726Nonecode108Supply of round/square recess/surface mounted rolling type LED Down light with . W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70per rcentage lumen maintenance with CRI Greater then 80. Power Input: 220-240V @50/60Hz & Power factor Greater then0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition. 11.5.3 LED square or round down light 15-18W Each1324.01324.06.0FalseNoneNoneFalseNoneFalse7944.00
17104132400000NoneNoneOther WorksDevelopemtn of Sevalal temple in ward no 4 in wadi town.2113916.34
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3070897104727Nonecode01Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including TandP and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead By Mechanical means Dismantling Brick / Tile work / rubble masonry / pitching / etc by mechanical meansCum189.0189.04.8FalseNoneNoneFalseNoneFalse907.20
3070898104727Nonecode02Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting and stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage and other appurtenances required to complete the work.Depth exceeding 1.5m, but not exceeding 3 mCum467.25467.2551.84FalseNoneNoneFalseNoneFalse24222.240
3070899104727Nonecode03Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum6288.456288.452.59FalseNoneNoneFalseNoneFalse16287.08550
3070900104727Nonecode04Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7170.287170.289.8FalseNoneNoneFalseNoneFalse70268.7440
3070901104727Nonecode05Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork to be paid separately) 2.3.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11566.811566.84.195FalseNoneNoneFalseNoneFalse48522.7260
3070902104727Nonecode06Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork to be paid separately) 2.3.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum10886.410886.40.4623FalseNoneNoneFalseNoneFalse5032.782720
3070903104727Nonecode07Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.339.45FalseNoneNoneFalseNoneFalse11018.3850
3070904104727Nonecode08Supplying, Fitting and Placing TMT Fe 500 and above Reinforcement in Foundation / Substructure Superstructure complete as per Drawing and Technical Specifications.Tonne90754.6590754.651.02FalseNoneNoneFalseNoneFalse92569.7430
3070905104727Nonecode09Providing and fixing self supported, ribbed. high quality, high grade (D:350 MPA Yst Min ), pre painted Galvalume steel roof sheet, coated with bare Galvalume coating AZ 150, at the rate 150 gms/Smtr 55PercentageAL.45PercentageZri) by hot qip process, of total coated thickness as specified for different spans with atolerance of 0.02 mm, according to technical specification confirming to A 792, with NCCA 11 1, or ECCA T 4 Pencil hardness Ha, NCCA standardSqm1365.01365.0116.58FalseNoneNoneFalseNoneFalse159131.70
3070906104727Nonecode10Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in Charge.Sqm142.8142.8582.9FalseNoneNoneFalseNoneFalse83238.120
3070907104727Nonecode11Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work.Cum8376.98376.913.565FalseNoneNoneFalseNoneFalse113632.64850
3070908104727Nonecode12Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in Charge.Kg154.35154.35508.714FalseNoneNoneFalseNoneFalse78520.00590
3070909104727Nonecode13Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per irections of the Engineer in Charge.Kg142.8142.8126.0FalseNoneNoneFalseNoneFalse17992.80
3070910104727Nonecode14Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, uring complete as per specifications and as per directions of Engineer in charge.Sqm253.05253.05277.1124FalseNoneNoneFalseNoneFalse70123.292820
3070911104727Nonecode15Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement ortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever equired smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in charge.Sqm389.55389.5560.1319FalseNoneNoneFalseNoneFalse23424.3816450
3070912104727Nonecode16Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm ominal size graded crushed coarse aggregatesSqm11138.411138.45.2916FalseNoneNoneFalseNoneFalse58939.957440
3070913104727Nonecode17Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per pecifications and as per directions of Engineer in charge.Sqm105.0105.0277.1124FalseNoneNoneFalseNoneFalse29096.8020
3070914104727Nonecode18Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per pecifications and as per directions of Engineer in charge.Sqm133.35133.35277.1124FalseNoneNoneFalseNoneFalse36952.938540
3070915104727Nonecode19Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied at the rate 1.43 ltr/10 m² over and including priming coat of exterior primer applied at the rate 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to move all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer in charge.Sqm186.9186.960.131FalseNoneNoneFalseNoneFalse11238.48390
3070916104727Nonecode20Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter ncluding preparing the surface even and sand paper smooth, cost of materials, labour complete as per pecifications and as per directions of Engineer in charge.Sqm120.75120.751027.5FalseNoneNoneFalseNoneFalse124070.6250
3070917104727Nonecode21Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer in charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in Charge.Mtr593.25593.2525.578FalseNoneNoneFalseNoneFalse15174.14850
3070918104727Nonecode22Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer in Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry at the rate 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete.Sqm1161.31161.3126.0FalseNoneNoneFalseNoneFalse146323.80
3070919104727Nonecode23Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesSqm6288.456288.4516.3125FalseNoneNoneFalseNoneFalse102580.3406250
3070920104727Nonecode24Toilet Block Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.(ii) By Mechanical Means using DozerB In area of thorny jungleSqm508.2508.20.25FalseNoneNoneFalseNoneFalse127.050
3070921104727Nonecode25Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering and leveling the ground for all works other than foundation and depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, trutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage and other appurtenances required to complete the work.Cum95.5595.554.32FalseNoneNoneFalseNoneFalse412.7760
3070922104727Nonecode26Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting and stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage and other appurtenances required to complete the work.Depth exceeding 1.5m, but not exceeding 3 mCum467.25467.2525.38FalseNoneNoneFalseNoneFalse11858.8050
3070923104727Nonecode27Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum6288.456288.453.0FalseNoneNoneFalseNoneFalse18865.350
3070924104727Nonecode28Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7348.327348.322.394FalseNoneNoneFalseNoneFalse17591.878080
3070925104727Nonecode29Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork to be paid separately) 2.3.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11566.811566.80.7632FalseNoneNoneFalseNoneFalse8827.781760
3070926104727Nonecode30Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork to be paid separately) 2.3.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum10886.410886.40.792FalseNoneNoneFalseNoneFalse8622.02880
3070927104727Nonecode31Providing Size Stone masonry with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6708.456708.454.752FalseNoneNoneFalseNoneFalse31878.55440
3070928104727Nonecode32Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer in charge.Sqm267.75267.757.92FalseNoneNoneFalseNoneFalse2120.580
3070929104727Nonecode33Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.322.31FalseNoneNoneFalseNoneFalse6231.1830
3070930104727Nonecode34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part I) 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1375.51375.522.14FalseNoneNoneFalseNoneFalse30453.570
3070931104727Nonecode35Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having lock density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part I) 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1159.21159.29.47FalseNoneNoneFalseNoneFalse10977.6240
3070932104727Nonecode36Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum6288.456288.450.045FalseNoneNoneFalseNoneFalse282.980250
3070933104727Nonecode37Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super lasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11138.411138.40.97FalseNoneNoneFalseNoneFalse10804.2480
3070934104727Nonecode38Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super lasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11138.411138.41.224FalseNoneNoneFalseNoneFalse13633.40160
3070935104727Nonecode39Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in charge.Sqm253.05253.0512.24FalseNoneNoneFalseNoneFalse3097.3320
3070936104727Nonecode40Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11138.411138.40.432FalseNoneNoneFalseNoneFalse4811.78880
3070937104727Nonecode41Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as specidfication and as per directionsof Engineer in chargeSqm11138.411138.40.43FalseNoneNoneFalseNoneFalse4789.5120
3070938104727Nonecode42Providing and fixing factory made UPVC Door Frame made of UPVC extruded sections having an overall dimension as below (tolerance +/ 1mm ) with wall thickness 2.00mm (+/ 2mm), corners of the door frames to be jointed with galvanised brackets and stainless steel screws,joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanised MS Tube of size 19mm X 19mm and 1mm (+/ 1mm) wall thickness and 3 Nos stainless steel hinges fixed to the frame complete as per manufacturer specification and direction of Engineer in charge.Sqm250.95250.9521.0FalseNoneNoneFalseNoneFalse5269.950
3070939104727Nonecode43Providing and fixing of openable Door made out of multi chambered UPVC (matching to RAL 9016) sections and with minimum Ti02 (Titanium Doxide) at 6PHR with TPV (Thermo Plastic Vulcanised) and lead free with gasket grey color having isolated drainage and reinforced with Galvanised Iron profile through out the openable frame. The frame having overall size of 60mm X 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm X 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm X 34mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge and multi point locking system with handle. Wall thickness of frame and sash shall be of 2mm 2.50mm. Maximum possible size 900mm X 2400mm. (The cost is inclusive of all fixtures and separate charge for minor TandP's shall not be made)Sqm6557.256557.2510.71FalseNoneNoneFalseNoneFalse70228.14750
3070940104727Nonecode44Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.Kg192.15192.1528.35FalseNoneNoneFalseNoneFalse5447.45250
3070941104727Nonecode45Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement ortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever equired smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in charge.Sqm389.55389.5524.93FalseNoneNoneFalseNoneFalse9711.48150
3070942104727Nonecode46Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, uring complete as per specifications and as per directions of Engineer in charge.Sqm253.05253.0540.08FalseNoneNoneFalseNoneFalse10142.2440
3070943104727Nonecode47Providing and laying red oxide flooring 40 mm thick, with an under layer of 30mm thick M 15 cement concrete and top layer of 10mm thick plaster with 1:3 cement mortar mixed with red oxide finished with floating coat of neat cement mixed with red oxide ( mix of same proportion ) , including Cost of materials, labour, curing, complete as per specifications.Sqm825.3825.38.32FalseNoneNoneFalseNoneFalse6866.4960
3070944104727Nonecode48Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer in Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement ortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry at the rate 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete.Sqm1161.31161.318.68FalseNoneNoneFalseNoneFalse21693.0840
3070945104727Nonecode49Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per pecifications and as per directions of Engineer in charge.Sqm105.0105.037.17FalseNoneNoneFalseNoneFalse3902.850
3070946104727Nonecode50Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per pecifications and as per directions of Engineer in charge.Sqm133.35133.3524.93FalseNoneNoneFalseNoneFalse3324.41550
3070947104727Nonecode51Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied at the rate 1.43 ltr/10 m² over and including priming coat of exterior primer applied at the rate 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to move all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer in charge.Sqm186.9186.924.93FalseNoneNoneFalseNoneFalse4659.4170
3070948104727Nonecode52Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineerin charge.Sqm27.327.324.93FalseNoneNoneFalseNoneFalse680.5890
3070949104727Nonecode53Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter ncluding preparing the surface even and sand paper smooth, cost of materials, labour complete as per pecifications and as per directions of Engineer in charge.Sqm120.75120.752.7FalseNoneNoneFalseNoneFalse326.0250
3070950104727Nonecode54Supplying, Fitting and Placing TMT Fe 500 and above Reinforcement in Foundation / Substructure Superstructure complete as per Drawing and Technical Specifications.Tonne90754.6590754.650.74FalseNoneNoneFalseNoneFalse67158.4410
3070951104727Nonecode55Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other ppurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork shall be paid separately) 2.1.4 Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregatesCum6527.856527.851.188FalseNoneNoneFalseNoneFalse7755.08580
3070952104727Nonecode56Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the ngineerin Charge.)Kg192.15192.15211.68FalseNoneNoneFalseNoneFalse40674.3120
3070953104727Nonecode57Providing and fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners and jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification and direction of Engineer in chargeSqm333.9333.910.71FalseNoneNoneFalseNoneFalse3576.0690
3070954104727Nonecode58Providing and fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top and bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet and 30x50mm wide to form stiles and 5mm thick and 75mm wide Prelaminated PVC Sheets for top rail, lock rail and bottom rail on either side and 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail and bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles and rails with PVC Designer beading on either side and joined together with solvent cement adhesive etc., Complete as per anufacturers specification and direction of Engineer in charge fixed to frames with 3 nos of 75mm Aluminium hinges.12.55.2 do with one side prelamCum2142.02142.010.71FalseNoneNoneFalseNoneFalse22940.820
3070955104727Nonecode59Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameterMtr305.55305.5530.0FalseNoneNoneFalseNoneFalse9166.50
3070956104727Nonecode60Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, if c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipesMtr397.95397.9515.0FalseNoneNoneFalseNoneFalse5969.250
3070957104727Nonecode61Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, if c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipesMtr584.85584.8515.0FalseNoneNoneFalseNoneFalse8772.750
3070958104727Nonecode62Providing and fixing Water Closet squatting pan (Indian type W.C. Pan) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. Pan of size 580x440 mm with integral type foot restsEach5128.25128.22.0FalseNoneNoneFalseNoneFalse10256.40
3070959104727Nonecode63Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 14.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar tapsEach3236.13236.12.0FalseNoneNoneFalseNoneFalse6472.20
3070960104727Nonecode64Providing and fixing brass stop cock of approved quality : 13.3.2 20 mm nominal boreEach320.25320.255.0FalseNoneNoneFalseNoneFalse1601.250
3070961104727Nonecode65Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 13.5.3 25 mm nominal boreEach348.6348.63.0FalseNoneNoneFalseNoneFalse1045.80
3070962104727Nonecode66Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base suooort for tank.Ltr9.459.451000.0FalseNoneNoneFalseNoneFalse9450.00
3070963104727Nonecode67Providing and fixing unplasticised PVC connection pipe with brass unions : 45 cm length 13.8.2.1 15 mm nominal boreNo95.5595.553.0FalseNoneNoneFalseNoneFalse286.650
3070964104727Nonecode68Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.No1281.01281.02.0FalseNoneNoneFalseNoneFalse2562.00
3070965104727Nonecode69Providing and fixing 100 mm sand cast Iron grating for gully trap.Each49.3549.352.0FalseNoneNoneFalseNoneFalse98.70
3070966104727Nonecode70Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting and stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage and other appurtenances required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth Page No.6 Item No. 1.5.1 KPWD. Volumn 1 DSR 2021 22Cum313.95313.95217.215FalseNoneNoneFalseNoneFalse68194.649250
3070967104727Nonecode71Providing Brick work with common burnt clay machine moulded perforated bricks of class designation 3.5 in superstructure above plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) With Non modular bricks including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work.Cum8367.458367.451.242FalseNoneNoneFalseNoneFalse10392.37290
3070968104727Nonecode72Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in charge.Sqm404.25404.2518.96FalseNoneNoneFalseNoneFalse7664.580
3070969104727Nonecode73Providing and laying 100mm thick pre cast cover slabs over drains and Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm 3ply wired steel at the rate 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. itm.no 17.12 Page No.152 KPWD. Volumn 2 DSR 2023 24Sqm974.4974.42.0667FalseNoneNoneFalseNoneFalse2013.792480
3070970104727Nonecode74Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe32 mm dia ( item no 14.28.2.1 ) page no 123 PWP. DSR 2021 22Each96.696.62.0FalseNoneNoneFalseNoneFalse193.20
3070971104727Nonecode75Electrical Work Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19/20mm dia 2mm thick.Mtr69.069.046.0FalseNoneNoneFalseNoneFalse3174.00
3070972104727Nonecode76Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25mm dia 2mm thick.Mtr81.081.046.0FalseNoneNoneFalseNoneFalse3726.00
3070973104727Nonecode77Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 32mm dia 2.5mm thick.Mtr100.0100.046.0FalseNoneNoneFalseNoneFalse4600.00
3070974104727Nonecode78Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19/20mm dia 2mm thickMtr68.068.046.0FalseNoneNoneFalseNoneFalse3128.00
3070975104727Nonecode79Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25mm dia 2mm thickMtr79.079.046.0FalseNoneNoneFalseNoneFalse3634.00
3070976104727Nonecode80Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary 32mm dia 2.5mm thickMtr99.099.060.0FalseNoneNoneFalseNoneFalse5940.00
3070977104727Nonecode81Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, screws at an interval of 300mm …. etc. as required. 25mmMtr35.035.090.0FalseNoneNoneFalseNoneFalse3150.00
3070978104727Nonecode82Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Short point upto 3m from tapping point to out let via switch boxPoint269.0269.06.0FalseNoneNoneFalseNoneFalse1614.00
3070979104727Nonecode83Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Medium point above 3m upto 6m from tapping point to out let via switch boxPoint379.0379.05.0FalseNoneNoneFalseNoneFalse1895.00
3070980104727Nonecode84Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Long point above 6m upto 10m from tapping point to out let via switch boxPoint555.0555.05.0FalseNoneNoneFalseNoneFalse2775.00
3070981104727Nonecode85Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Two outlet in a row, above 3m upto 6m from tapping point to out let via switchesPoint677.0677.05.0FalseNoneNoneFalseNoneFalse3385.00
3070982104727Nonecode86Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Three outlet in a row, above 6m upto 10m from tapping point to out let via switches boxPoint989.0989.04.0FalseNoneNoneFalseNoneFalse3956.00
3070983104727Nonecode87Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:confirming to latest amendments. 1.5 mm2Mtr26.026.070.0FalseNoneNoneFalseNoneFalse1820.00
3070984104727Nonecode88Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:confirming to latest amendments.2.5 mm2Mtr42.042.060.0FalseNoneNoneFalseNoneFalse2520.00
3070985104727Nonecode89Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:confirming to latest amendments. 4 mm2Mtr63.063.060.0FalseNoneNoneFalseNoneFalse3780.00
3070986104727Nonecode90Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:confirming to latest amendments.6 mm2Mtr87.087.060.0FalseNoneNoneFalseNoneFalse5220.00
3070987104727Nonecode91Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:confirming to latest amendments 10 mm2Mtr167.0167.040.0FalseNoneNoneFalseNoneFalse6680.00
3070988104727Nonecode92Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3 WayEach159.0159.08.0FalseNoneNoneFalseNoneFalse1272.00
3070989104727Nonecode93Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6 WayEach220.0220.06.0FalseNoneNoneFalseNoneFalse1320.00
3070990104727Nonecode94Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 ModuleEach161.0161.05.0FalseNoneNoneFalseNoneFalse805.00
3070991104727Nonecode95Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 ModuleEach234.0234.04.0FalseNoneNoneFalseNoneFalse936.00
3070992104727Nonecode96LED Indoor Supplying of .feet PVC Batten with integrated LED tube . W with high quality diffuser with Life of 25000 burning hours and 70Percentage lumen maintenance with CRI Smaller than 80. Power Input: 220 240Vat the rate 50/60Hz and Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4 36/40 WEach1269.01269.04.0FalseNoneNoneFalseNoneFalse5076.00
3070993104727Nonecode97Supply of round/square recess/surface mounted rolling type LED Down light with . W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector and has swivelling unit of aluminium die cast eye ball and LED Lamp position retained by circular wire spring, with Life of 25000 burning hours and 70Percentage lumen maintenance with CRI Smaller than 80. Power Input: 220 240V at the rate50/60Hz and Power factor Smaller than0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition. LED square or round down light 15 18WEach1324.01324.06.0FalseNoneNoneFalseNoneFalse7944.00
3070994104727Nonecode98LED Down light Supplying of recess mounting non integrated type LED down light. W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clA, LED of Power/COB with CCT 6500 degree K, CRISmaller than 70Percentage. efficacy Smaller than100 lumen per W, 120degree beam spread, lifeSmaller than 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 and LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PF Smaller than 0.95, power loss shouldGreater then 5Percentage of lamp Wage, short circuit and open circuit protection to be integrated in the circuit, THD less than 20Percentage, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited aboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.15 18WEach1671.01671.010.0FalseNoneNoneFalseNoneFalse16710.00
3070995104727Nonecode99Supplying and fixing of round or oblong type bulk head fitting glass coverEach68.068.06.0FalseNoneNoneFalseNoneFalse408.00
3070996104727Nonecode100Fixing all types and all capacities fluorescent/false ceiling/spot light/ CFL fittings indoor on the wall/ ceiling/rafters/girders using 23/0.0076'' twin PVC insulated wires, required nos of round blocks and clamps (if required) On wall/ ceiling / Rafter / GirdersEach122.0122.010.0FalseNoneNoneFalseNoneFalse1220.00
3070997104727Nonecode101Fixing a ceiling/wall mounting fan of all capacities and all types with necessary clamps and S hook made out of 15mm dia MS rod, with 5 amps ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality mounted on a suitable size wooden board and wired complete.Each315.0315.04.0FalseNoneNoneFalseNoneFalse1260.00
3070998104727Nonecode102Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.Each707.0707.04.0FalseNoneNoneFalseNoneFalse2828.00
3070999104727Nonecode103Supplying . amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100 A 4 x 30 x 6 mm Aluminium StripsMtr2465.02465.02.0FalseNoneNoneFalseNoneFalse4930.00
3071000104727Nonecode104Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mmMtr305.0305.05.0FalseNoneNoneFalseNoneFalse1525.00
3071001104727Nonecode105Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 50 x 100 x 50 x 6 mm C channelMtr680.0680.06.0FalseNoneNoneFalseNoneFalse4080.00
3071002104727Nonecode106Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS 13947. (Icu=100Percentage lcs). In 4P MCCB, all Poles should have protection for Short Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. THREE Pole 100 A 25 kAEach6086.06086.04.0FalseNoneNoneFalseNoneFalse24344.00
3071003104727Nonecode107Supplying, fixing and wiring Residual current circuit breaker (RCCB)240/450V upto 300mA sensitivity on existing wood/ panel board. 32 40 A 4 poleEach5147.05147.02.0FalseNoneNoneFalseNoneFalse10294.00
3071004104727Nonecode108Supplying and fixing of Shunt trip suitable for MCCB.CBCT.Each1703.01703.02.0FalseNoneNoneFalseNoneFalse3406.00
3071005104727Nonecode109Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each9255.09255.01.0FalseNoneNoneFalseNoneFalse9255.00
3071006104727Nonecode110Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each515.0515.02.0FalseNoneNoneFalseNoneFalse1030.00
3071007104727Nonecode111Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound.Each562.0562.02.0FalseNoneNoneFalseNoneFalse1124.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17104132410000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17104132410000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17104132410000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneMinimum financial turnover (Civil engineering construction works) not less than two time the annual payments from the contract (Rs.95.85 Lakhs)OthersMinimum financial turnover
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Minimum financial turnover
NoneNoneNoneNoneSatisfactorily completed (atleast 90%) as prime contractor at-least one similat work of vale not less then Rs. 76.68 Lakhs(80% of the estimated cost of tender)OthersSatisfactorily completed (
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Satisfactorily completed
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
To qualify for award of this contract each tenderer in his name should have in the last five years period achieved in the last two years at least two financial years an average annual financial turnover of Rs.95.85 Lakhs.TrueTechnical Bid
Eligible Registered PWD Contractor.TrueTechnical Bid
Similar Nature of Work Done Certificate achieved at least 50 Percent of Estimate Cost 47.92 Lakhs.TrueTechnical Bid
IT return Certificate Last 3 years.TrueTechnical Bid
GST Registration Certificate and PAN Card.TrueTechnical Bid
Liquid assets and or availability of credit facilities of not less than Rs 28.75 Lakhs.TrueTechnical Bid
As per the KW-3 Tender document.TrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1710416725000
version0
createdDateNone
modifiedDateNone
blockNumberExecutive Engineer DUDC Kalaburagi
streetNone
cityKalaburagi
stateKarnataka
pin585101
tenderRecallDTONone