3069794 | 104668 | None | code01 | Clearing Grass and Removal of Rubbish & dumping to outside periphery by manual means | Sqm | 28451.0 | 28451.0 | 0.4 | False | None | None | False | None | False | 11380.4 | 0 |
3069795 | 104668 | None | code02 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse, in a radius of 50 m and lift upto 1.5 m including Cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. | Cum | 81.76 | 81.76 | 793.99 | False | None | None | False | None | False | 64916.6224 | 0 |
3069796 | 104668 | None | code03 | Rubble Soling:. Providing and Filling in foundation with granite / trap broken metal 100mm and down size with approved M.Sand including hand packing, ramming, watering including cost of all materials and labour with all lead and lift complete as per specifications. | Cum | 1784.16 | 1784.16 | 43.71 | False | None | None | False | None | False | 77985.6336 | 0 |
3069797 | 104668 | None | code04 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm and down size graded crushed coarse aggregates | Cum | 6220.48 | 6220.48 | 41.058 | False | None | None | False | None | False | 255400.46784 | 0 |
3069798 | 104668 | None | code05 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm and down size graded crushed coarse aggregates | Cum | 6415.36 | 6415.36 | 7.35 | False | None | None | False | None | False | 47152.896 | 0 |
3069799 | 104668 | None | code06 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including centring and shuttering as per Appendix.I | Cum | 7321.78 | 7321.78 | 135.53 | False | None | None | False | None | False | 992320.8434 | 0 |
3069800 | 104668 | None | code07 | Providing Thermo.Mechanically Treated bars of grade Fe.500D or more Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) TMT bars Fe 500 | Kg | 103.04 | 103.04 | 13553.1 | False | None | None | False | None | False | 1396511.424 | 0 |
3069801 | 104668 | None | code08 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. | Sqm | 44.8 | 44.8 | 556.38 | False | None | None | False | None | False | 24925.824 | 0 |
3069802 | 104668 | None | code09 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer.in.charge. | Sqm | 145.6 | 145.6 | 556.38 | False | None | None | False | None | False | 81008.928 | 0 |
3069803 | 104668 | None | code10 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete PVC PIPES OF 10 Kg./Cm2 | m | 640.64 | 640.64 | 228.8 | False | None | None | False | None | False | 146578.432 | 0 |
3069804 | 104668 | None | code11 | Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 110 mm dia PVC Tee | No | 293.44 | 293.44 | 12.0 | False | None | None | False | None | False | 3521.28 | 0 |
3069805 | 104668 | None | code12 | Supply and delivery at site special moulded variety PVC bend as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments | No | 574.56 | 574.56 | 48.0 | False | None | None | False | None | False | 27578.88 | 0 |
3069806 | 104668 | None | code13 | PVC 160mm dia pipes for support | m | 670.88 | 670.88 | 19.38 | False | None | None | False | None | False | 13001.6544 | 0 |
3069807 | 104668 | None | code14 | Providing and laying of coarse aggregate size as below after washing & sieving to make it free from fines & dust. 53 mm nominal size | Cum | 1526.34 | 1526.34 | 14.7 | False | None | None | False | None | False | 22437.198 | 0 |
3069808 | 104668 | None | code15 | Providing and laying of coarse aggregate size as below after washing & sieving to make it free from fines & dust. 20 mm nominal size | Cum | 1638.34 | 1638.34 | 7.35 | False | None | None | False | None | False | 12041.799 | 0 |
3069809 | 104668 | None | code16 | Providing and laying of coarse aggregate size as below after washing & sieving to make it free from fines & dust.12.5 mm nominal size | Cum | 1638.34 | 1638.34 | 7.35 | False | None | None | False | None | False | 12041.799 | 0 |
3069810 | 104668 | None | code17 | Providing and laying of coarse aggregate size as below after washing & sieving to make it free from fines & dust. Sand/Artificial Sand/Manufactured Sand | Cum | 2102.02 | 2102.02 | 14.7 | False | None | None | False | None | False | 30899.694 | 0 |
3069811 | 104668 | None | code18 | Providing, casting, curing and laying the following CC slabs Percolate channel perforated slabs (880x500x75 mm) | No | 541.17 | 541.17 | 48.0 | False | None | None | False | None | False | 25976.16 | 0 |
3069812 | 104668 | None | code19 | Providing and fixing MS inspection door of size 60 cms x 60 cms, including MS frame made of 50x50x6mm angle, shutters made of 3mm thick MS sheets, with hinges, locking arrangements at top etc. including painting with anticorrosive approved paint etc. complete including all lead and lifts etc M.S Guage sheet for 1.5 m | No | 3809.12 | 3809.12 | 12.0 | False | None | None | False | None | False | 45709.44 | 0 |
3069813 | 104668 | None | code20 | Providing and fixing 12.5mm to 25 mm expanded metal work of 14 gauge with Mathi or Nandi wood patties of 50 mm x 12 mm size, including two coats approved paint etc., complete. (Including cost of screws). including cost of materials, labour, HOM complete as per specifications. .do. with weld mesh 75 mm X 25 mm 6G X 10G. | Sqm | 1641.2 | 1641.2 | 185.5 | False | None | None | False | None | False | 304442.6 | 0 |
3069814 | 104668 | None | code21 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L.Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer: Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer.in.Charge. 25x25x3 mm Angle(1.10kg/m) | Kg | 116.6 | 116.6 | 480.7 | False | None | None | False | None | False | 56049.62 | 0 |
3069815 | 104668 | None | code22 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse, in a radius of 50 m and lift upto 1.5 m including Cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. | Cum | 81.76 | 81.76 | 49.42 | False | None | None | False | None | False | 4040.5792 | 0 |
3069816 | 104668 | None | code23 | Providing and Filling in foundation with granite / trap broken metal 100mm and down size with approved M.Sand including hand packing, ramming, watering including cost of all materials and labour with all lead and lift complete as per specifications | Cum | 1784.16 | 1784.16 | 5.2 | False | None | None | False | None | False | 9277.632 | 0 |
3069817 | 104668 | None | code24 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm and down size graded crushed coarse aggregates | Cum | 6220.48 | 6220.48 | 2.478 | False | None | None | False | None | False | 15414.34944 | 0 |
3069818 | 104668 | None | code25 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including centring and shuttering as per Appendix.I | Cum | 9984.24 | 9984.24 | 3.701 | False | None | None | False | None | False | 36951.67224 | 0 |
3069819 | 104668 | None | code26 | Providing Thermo.Mechanically Treated bars of grade Fe.500D or more Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) TMT bars Fe 500 | Kg | 103.04 | 103.04 | 370.125 | False | None | None | False | None | False | 38137.68 | 0 |
3069820 | 104668 | None | code27 | Providing and constracting Lattrate size stone mansanary including cost and convence of all materils curing ..etc complete as per srecifications is.3620/1979 having compressive strength not less than 3.50 n/mm saturated dry sample for superstracture in cm 1:6 | Cum | 6611.36 | 6611.36 | 5.72 | False | None | None | False | None | False | 37816.9792 | 0 |
3069821 | 104668 | None | code28 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm and down size graded crushed coarse aggregates | Cum | 1150.24 | 1150.24 | 0.7686 | False | None | None | False | None | False | 884.074464 | 0 |
3069822 | 104668 | None | code29 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer.in.charge. | Sqm | 334.88 | 334.88 | 53.395 | False | None | None | False | None | False | 17880.9176 | 0 |
3069823 | 104668 | None | code30 | Extra for providing and mixing waterproofing compound in cement plaster for stone masonry work at one kg per bag or in the proportion recommended by the manufacturers, for cement mortar 1:4, 20mm thick cost of materials complete as per specifications. | Sqm | 57.12 | 57.12 | 53.395 | False | None | None | False | None | False | 3049.9224 | 0 |
3069824 | 104668 | None | code31 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete PVC PIPES OF 10 Kg./Cm2 | m | 640.64 | 640.64 | 14.0 | False | None | None | False | None | False | 8968.96 | 0 |
3069825 | 104668 | None | code32 | Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 110 mm dia PVC Tee | No | 293.44 | 293.44 | 12.0 | False | None | None | False | None | False | 3521.28 | 0 |
3069826 | 104668 | None | code33 | Supply and delivery at site special moulded variety PVC bend as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments | No | 574.56 | 574.56 | 48.0 | False | None | None | False | None | False | 27578.88 | 0 |
3069827 | 104668 | None | code34 | PVC 160mm dia pipes for support | m | 670.88 | 670.88 | 19.38 | False | None | None | False | None | False | 13001.6544 | 0 |
3069828 | 104668 | None | code35 | Providing and fixing MS inspection door of size 60 cms x 60 cms, including MS frame made of 50x50x6mm angle, shutters made of 3mm thick MS sheets, with hinges, locking arrangements at top etc. including painting with anticorrosive approved paint etc. complete including all lead and lifts etc. M.S Guage sheet for 1.5 m | No | 3809.12 | 3809.12 | 3.0 | False | None | None | False | None | False | 11427.36 | 0 |
3069829 | 104668 | None | code36 | Providing, casting, curing and laying the following CC slabs 600 mm x 600 mm x 50 mm | No | 295.18 | 295.18 | 3.0 | False | None | None | False | None | False | 885.54 | 0 |
3069830 | 104668 | None | code37 | Providing, casting, curing and laying the following CC slabs Perforated slabs 700 mm x 550 mm x 50 mm | No | 631.36 | 631.36 | 4.0 | False | None | None | False | None | False | 2525.44 | 0 |
3069831 | 104668 | None | code38 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse, in a radius of 50 m and lift upto 1.5 m including Cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. | Cum | 81.76 | 81.76 | 94.12 | False | None | None | False | None | False | 7695.2512 | 0 |
3069832 | 104668 | None | code39 | Providing and Filling in foundation with granite / trap broken metal 100mm and down size with approved M.Sand including hand packing, ramming, watering including cost of all materials and labour with all lead and lift complete as per specifications. | Cum | 1784.16 | 1784.16 | 3.393 | False | None | None | False | None | False | 6053.65488 | 0 |
3069833 | 104668 | None | code40 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm and down size graded crushed coarse aggregates | Cum | 6966.4 | 6966.4 | 4.249 | False | None | None | False | None | False | 29600.2336 | 0 |
3069834 | 104668 | None | code41 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including centring and shuttering as per Appendix.I | Cum | 9984.24 | 9984.24 | 7.117 | False | None | None | False | None | False | 71057.83608 | 0 |
3069835 | 104668 | None | code42 | Providing Thermo.Mechanically Treated bars of grade Fe.500D or more Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) TMT bars Fe 500 | Kg | 103.04 | 103.04 | 711.7 | False | None | None | False | None | False | 73333.568 | 0 |
3069836 | 104668 | None | code43 | Providing and constracting Lattrate size stone mansanary including cost and convence of all materils curing ..etc complete as per srecifications is.3620/1979 having compressive strength not less than 3.50 n/mm saturated dry sample for superstracture in cm 1:6 | Cum | 6611.36 | 6611.36 | 5.818 | False | None | None | False | None | False | 38464.89248 | 0 |
3069837 | 104668 | None | code44 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer.in.charge. | Sqm | 334.88 | 334.88 | 67.65 | False | None | None | False | None | False | 22654.632 | 0 |
3069838 | 104668 | None | code45 | Extra for providing and mixing waterproofing compound in cement plaster for stone masonry work at one kg per bag or in the proportion recommended by the manufacturers, for cement mortar 1:4, 20mm thick cost of materials complete as per specifications. | Sqm | 57.12 | 57.12 | 67.6525 | False | None | None | False | None | False | 3864.3108 | 0 |
3069839 | 104668 | None | code46 | Wastewater Pipes, Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete PVC PIPES OF 10 Kg./Cm2 | m | 640.64 | 640.64 | 12.72 | False | None | None | False | None | False | 8148.9408 | 0 |
3069840 | 104668 | None | code47 | Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 110 mm dia PVC Tee | No | 293.44 | 293.44 | 12.0 | False | None | None | False | None | False | 3521.28 | 0 |
3069841 | 104668 | None | code48 | Supply and delivery at site special moulded variety PVC bend as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments | No | 574.56 | 574.56 | 48.0 | False | None | None | False | None | False | 27578.88 | 0 |
3069842 | 104668 | None | code49 | PVC 160mm dia pipes for support | m | 670.88 | 670.88 | 19.38 | False | None | None | False | None | False | 13001.6544 | 0 |
3069843 | 104668 | None | code50 | Filter media, Providing and laying of coarse aggregate size as below after washing & sieving to make it free from fines & dust.100 mm and down nominal size of stone aggregate | Cum | 1470.34 | 1470.34 | 0.24 | False | None | None | False | None | False | 352.8816 | 0 |
3069844 | 104668 | None | code51 | 20 mm nominal size | Cum | 1638.34 | 1638.34 | 0.7 | False | None | None | False | None | False | 1146.838 | 0 |
3069845 | 104668 | None | code52 | 12.5 mm nominal size | Cum | 1638.34 | 1638.34 | 0.7 | False | None | None | False | None | False | 1146.838 | 0 |
3069846 | 104668 | None | code53 | 53 mm nominal size inCollection tank | Cum | 1526.34 | 1526.34 | 10.507 | False | None | None | False | None | False | 16037.25438 | 0 |
3069847 | 104668 | None | code54 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer.in.Charge. | Kg | 136.0 | 136.0 | 4086.86 | False | None | None | False | None | False | 555812.96 | 0 |
3069848 | 104668 | None | code55 | Providing and fixing precoated galvanised iron pro le sheets (size, shape and pitch of corrugation as approved by Engineer.in.charge) 0.50 mm (+ 0.05 percentage) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5.7 microns epoxy primer on both side of the sheet and polyester top coat 15.18 microns. Sheet should have protective guard lm of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12m or as desired by Engineer.in.charge. The sheet shall be xed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. | Sqm | 622.72 | 622.72 | 276.0 | False | None | None | False | None | False | 171870.72 | 0 |
3069849 | 104668 | None | code56 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 percentage) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5.7 microns epoxy primer on both side of the sheet and polyester top coat 15.18 microns using self drilling/ self tapping screws complete : Gutter (600 mm over all girth) vol.02 it no 7.39.6 pg no:27 | m | 957.6 | 957.6 | 46.0 | False | None | None | False | None | False | 44049.6 | 0 |
3069850 | 104668 | None | code57 | Earth work excavation for Foundation by manual means for all Buildings,Bridges, Retaining walls, Abutment Piers and such similar works as per drawing and technical Specifications, including setting out, providing shoring & srutting,barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work In all kinds of soils Depth upto 1.5 m | Cum | 208.32 | 208.32 | 90.0 | False | None | None | False | None | False | 18748.8 | 0 |
3069851 | 104668 | None | code58 | Embankment, Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 450.24 | 450.24 | 168.75 | False | None | None | False | None | False | 75978.0 | 0 |
3069852 | 104668 | None | code59 | Granular Sub Base, Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with 3 wheeled steel/ vibratory roller in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density PWD Roads | Cum | 2821.28 | 2821.28 | 45.0 | False | None | None | False | None | False | 126957.6 | 0 |
3069853 | 104668 | None | code60 | Cement Concrete Pavement with OPC/PPC/PSC, Providing and constructing un.reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, , primer, sealant , curing of concrete slabs for 14. days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the
directions of the Engineer.in.charge of the work. | Sqm | 8965.0 | 8965.0 | 45.0 | False | None | None | False | None | False | 403425.0 | 0 |
3069854 | 104668 | None | code61 | Earthwork Excavation, Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. | Cum | 78.4 | 78.4 | 42.0 | False | None | None | False | None | False | 3292.8 | 0 |
3069855 | 104668 | None | code62 | Granular Sub Base, Construction of Granular Sub.Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 | Cum | 2556.96 | 2556.96 | 28.0 | False | None | None | False | None | False | 71594.88 | 0 |
3069856 | 104668 | None | code63 | Wet Mix Macadam, Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub.base / base course on well prepared surface and compacting with vibratory roller to achieve the desired densit | Cum | 2681.28 | 2681.28 | 21.0 | False | None | None | False | None | False | 56306.88 | 0 |
3069857 | 104668 | None | code64 | Providing and applying primer coat with SS1 grade Bituminous Emulsionon prepared surface of granular Base including clearing of road surfaceandspraying primer at the rate of 0.90 kg/m2 using mechanical means. | Sqm | 49.28 | 49.28 | 140.0 | False | None | None | False | None | False | 6899.2 | 0 |
3069858 | 104668 | None | code65 | Open.Graded Premix Carpet, Providing, laying and rolling of open . graded premix surfacing of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using viscosity grade bitumen VG.30 to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable Hot mix plant of capacity not less than 40/60 TPH laying and rolling with a smooth wheeled roller, finished to required level and grades. | Sqm | 169.12 | 169.12 | 140.0 | False | None | None | False | None | False | 23676.8 | 0 |
3069859 | 104668 | None | code66 | Providing and applying tack coat with RS1 Bituminous Emulsion using emulsion pressure distributor at the rate of 0.20 kg/m2 on the prepared bituminous surface cleaned with mechanical broom, Tack coat over WMM | Sqm | 13.44 | 13.44 | 140.0 | False | None | None | False | None | False | 1881.6 | 0 |
3069860 | 104668 | None | code67 | Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A and B sealcoats Case . I : Type A Premix Sand Seal coat, Bitumen (S.90) seal coat over WMM By Mechanical Means | Sqm | 74.0 | 74.0 | 140.0 | False | None | None | False | None | False | 10360.0 | 0 |
3069861 | 104668 | None | code68 | Plantation , KSRRB M300.3. Making lawns including ploughing and breaking of clod, removal of rubbish, dressing and supplying doobs grass roots and planting at 15 em apart, including supplying and spreading of farm yard manure at rate of 0.18 cum per 100 sqm complete as per specifiifications. MORTH Specification No. 307 KSRRB M300. Maintenance of lawns or Turfing. | Sqm | 17.92 | 17.92 | 1791.16 | False | None | None | False | None | False | 32097.5872 | 0 |
3069862 | 104668 | None | code69 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work, Excavation for Foundation.(Centre line length 12.16 mtr | Cum | 81.76 | 81.76 | 25.536 | False | None | None | False | None | False | 2087.82336 | 0 |
3069863 | 104668 | None | code70 | Providing and Filling in foundation with granite / trap broken metal 100mm and down size with approved M.Sand including hand packing, ramming, watering including cost of all materials and labour with all lead and lift complete as per specifications. | Cum | 1784.16 | 1784.16 | 5.107 | False | None | None | False | None | False | 9111.70512 | 0 |
3069864 | 104668 | None | code71 | Plain Cement Concrete,Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm and down size graded crushed coarse aggregates | Cum | 6442.24 | 6442.24 | 1.459 | False | None | None | False | None | False | 9399.22816 | 0 |
3069865 | 104668 | None | code72 | PCC Below Flooring,Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers notexceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separatelyMix 1:2:4 (M15) Using 40 mm and down size graded crushed coarse aggregates) | Cum | 6637.12 | 6637.12 | 0.786 | False | None | None | False | None | False | 5216.77632 | 0 |
3069866 | 104668 | None | code73 | Providing and constructing laterite size stone masonry including cost and conveyance of material curing etc. complete as per specification.I.S.3620/1979 having compressive strength not less then 3.5N/mm2 for saturated dry samples For Foundation in CM 1:6 | Cum | 6265.28 | 6265.28 | 5.7456 | False | None | None | False | None | False | 35997.792768 | 0 |
3069867 | 104668 | None | code74 | Reinforced Cement Concrete, Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including centring and shuttering as per Appendix.I | Cum | 9984.24 | 9984.24 | 4.4652 | False | None | None | False | None | False | 44581.628448 | 0 |
3069868 | 104668 | None | code75 | Providing Thermo.Mechanically Treated bars of grade Fe.500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | Kg | 103.04 | 103.04 | 446.52 | False | None | None | False | None | False | 46009.4208 | 0 |
3069869 | 104668 | None | code76 | Providing and constracting Lattrate size stone mansanary including cost and convence of all materils curing ..etc complete as per srecifications is.3620/1979 having compressive strength not less than 3.50 n/mm saturated dry sample for superstracture in cm 1:6 | Cum | 6611.36 | 6611.36 | 9.471 | False | None | None | False | None | False | 62616.19056 | 0 |
3069870 | 104668 | None | code77 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part . I) . 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Cum | 1052.8 | 1052.8 | 5.235 | False | None | None | False | None | False | 5511.408 | 0 |
3069871 | 104668 | None | code78 | Providing & fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top & bottom rails, covered with heat moulded PVC C channel of 5mm thick sheet & 30 x 50mm wide to form stiles & 5mm thick & 75mm wide PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the stiles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer.in.charge fixed to frames with 3 nos of 75 mm Aluminium hinges | Sqm | 3188.64 | 3188.64 | 4.095 | False | None | None | False | None | False | 13057.4808 | 0 |
3069872 | 104668 | None | code79 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer.in.charge | Sqm | 343.84 | 343.84 | 98.36 | False | None | None | False | None | False | 33820.1024 | 0 |
3069873 | 104668 | None | code80 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement:4fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specificationsand as per directions of Engineer.in.charge. | Sqm | 244.16 | 244.16 | 7.86 | False | None | None | False | None | False | 1919.0976 | 0 |
3069874 | 104668 | None | code81 | Providing and laying red oxide flooring 40 mm thick, with an under layer of 30mm thick M.15 cement concrete and top layer of 10mm thick plaster with 1:3 cement mortar mixed with red oxide finished with floating coat of neat cement mixed with red oxide ( mix of same proportion ) , including cost of materials, labour, curing, complete as per specifications | Sqm | 715.68 | 715.68 | 9.024 | False | None | None | False | None | False | 6458.29632 | 0 |
3069875 | 104668 | None | code82 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer. in.Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. | Sqm | 1090.88 | 1090.88 | 5.76 | False | None | None | False | None | False | 6283.4688 | 0 |
3069876 | 104668 | None | code83 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer.in.Charge. | Sqm | 3862.88 | 3862.88 | 4.095 | False | None | None | False | None | False | 15818.4936 | 0 |
3069877 | 104668 | None | code84 | Providing & xing of 2.track x 2.panel sliding windows made out of multi chambered UPVC(Matching to RAL.9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets .grey color having isolated drainageand reinforced withGalvanized Iron pro le through.out the window frame. The outer frame having an overall size of 44mm width x 40mm height with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for xing of glassshall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain .oat glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2mm.Maximum possible size . 1219 mm x 1219mm. he cost is inclusive of all fixtures and separate charges for minor T&P's shall not be | Sqm | 4607.68 | 4607.68 | 4.725 | False | None | None | False | None | False | 21771.288 | 0 |
3069878 | 104668 | None | code85 | Providing and fixing M.S. grills of required pattern in frames ofwindows etc. with M.S. .ats, square or round bars etc. including primingcoat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.2 | Kg | 143.0 | 143.0 | 50.51 | False | None | None | False | None | False | 7222.93 | 0 |
3069879 | 104668 | None | code86 | Finishing walls with 100percentage Premium acrylic emulsion paint havingVOC less than 50 gm/litre and UV resistance as per IS 15489:2004,Alkali & fungal resistance, dirt resistance exterior paint of requiredshade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat ofexterior primer applied @ 0.90 litre/10 m² with paint of approvedquality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter includingpreparing thesurface even and sand paper smooth, cost of materials, labour completeas per speci cations and as per directions of Engineer.in.charge. | Sqm | 125.44 | 125.44 | 98.36 | False | None | None | False | None | False | 12338.2784 | 0 |
3069880 | 104668 | None | code87 | Distempering with oil bound washable distemper of approved brand andmanufacture to give an even shade :New work (two coats) over andincluding waterthinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar dropsand foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per speci cations and asper directions of Engineer.in.charge.(Internal Painting) | Sqm | 117.6 | 117.6 | 7.86 | False | None | None | False | None | False | 924.336 | 0 |
3069881 | 104668 | None | code88 | Providing and fixing water closet squatting pan (Indian type W.C. pan )with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C.flushing cistern, including flush pipe, with manually ontrolleddevice (handle lever) conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls andfloors wherever required: White Vitreous china Orissa pattern W.C. panof size 580x440 mm with integral type foot rests | Each | 4755.52 | 4755.52 | 1.0 | False | None | None | False | None | False | 4755.52 | 0 |
3069882 | 104668 | None | code89 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern | Unit | 3960.32 | 3960.32 | 1.0 | False | None | None | False | None | False | 3960.32 | 0 |
3069883 | 104668 | None | code90 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brasspillar taps, 32 mm C.P. brass waste of standard pattern, includingpainting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mmwith a pair of 15mm C.P. brass pillar taps | Unit | 2832.48 | 2832.48 | 1.0 | False | None | None | False | None | False | 2832.48 | 0 |
3069884 | 104668 | None | code91 | Providing and fixing 100 mm sand cast Iron grating for gully trap.). | Each | 229.6 | 229.6 | 4.0 | False | None | None | False | None | False | 918.4 | 0 |
3069885 | 104668 | None | code92 | Providing and fixing brass bib cock of approved quality : 20 mm nominal bore | Each | 386.4 | 386.4 | 4.0 | False | None | None | False | None | False | 1545.6 | 0 |
3069886 | 104668 | None | code93 | Providing and fixing Chorinated Poly Vinyl Chloride (CPVC) pipesconforming to IS 15778, having thermal stability for hot and cold watersupply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1 00 mtr spacing. This includes Joining of pipes and fittings with one step CPVC solvent cement and testing of joints complete. (internal work exposed on wall) | m | 175.84 | 175.84 | 30.0 | False | None | None | False | None | False | 5275.2 | 0 |
3069887 | 104668 | None | code94 | Providing and placing on terrace, polyethylene water storage tanks as per IS12701 : 1996 with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes, including cost of all materials, labour, transport charges, HOM and testing complete as per specifications. (For 1000 litre capacity)
Specification | No | 8.96 | 8.96 | 1000.0 | False | None | None | False | None | False | 8960.0 | 0 |
3069888 | 104668 | None | code95 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water fortesting) etc. for: | m | 7221.0 | 7221.0 | 14.0 | False | None | None | False | None | False | 101094.0 | 0 |
3069889 | 104668 | None | code96 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse, in a radius of 50 m and lift upto 1.5 m including Cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. | Cum | 81.76 | 81.76 | 51.9894 | False | None | None | False | None | False | 4250.653344 | 0 |
3069890 | 104668 | None | code97 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm and down size graded crushed coarse aggregates | Cum | 6415.36 | 6415.36 | 7.6 | False | None | None | False | None | False | 48756.736 | 0 |
3069891 | 104668 | None | code98 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including centring and shuttering as per Appendix.I | Cum | 10310.33 | 10310.33 | 24.048 | False | None | None | False | None | False | 247942.81584 | 0 |
3069892 | 104668 | None | code99 | Providing Thermo.Mechanically Treated bars of grade Fe.500D or more Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | Kg | 103.04 | 103.04 | 721.44 | False | None | None | False | None | False | 74337.1776 | 0 |
3069893 | 104668 | None | code100 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer.in.charge. | Sqm | 334.88 | 334.88 | 44.83 | False | None | None | False | None | False | 15012.6704 | 0 |
3069894 | 104668 | None | code101 | Extra for providing and mixing waterproofing compound in cement plaster for stone masonry work at one kg per bag or in the proportion recommended by the manufacturers, for cement mortar 1:4, 20mm thick cost of materials complete as per specifications. | Sqm | 57.12 | 57.12 | 44.83 | False | None | None | False | None | False | 2560.6896 | 0 |
3069895 | 104668 | None | code102 | KSRRB MS00.29.1. Providing and laying of a reinforced cement concrete pipe duct, 300 mm dia, across the road (new construction), extending from drain to drain in cuts and toe of slope to toe of slope in fills, constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipe as per IRC:98.1997, bedded on a 0.3 m thick layer of granular material free of rock pieces, outer to outer distance of pipe at least half dia of pipe subject to minimum450 mm in case of double and triple row ducts, JOints to be made leak proof, invert level of ductto be above higher than ground level to prevent entry of water and dirt, all as per IRC: 98. 1997 and approved drawings complete as per specifications. Case. I : Single row for one utility service PW, P&IWTD B | m | 1934.24 | 1934.24 | 7.98 | False | None | None | False | None | False | 15435.2352 | 0 |
3069896 | 104668 | None | code103 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete PVC PIPES OF 10 Kg./Cm2 | m | 640.64 | 640.64 | 53.2 | False | None | None | False | None | False | 34082.048 | 0 |
3069897 | 104668 | None | code104 | Providing, casting, curing and laying the following CC slabs | Each | 401.78 | 401.78 | 3.0 | False | None | None | False | None | False | 1205.34 | 0 |
3069898 | 104668 | None | code105 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse, in a radius of 50 m and lift upto 1.5 m including Cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. | m | 81.76 | 81.76 | 30.0 | False | None | None | False | None | False | 2452.8 | 0 |
3069899 | 104668 | None | code106 | Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. | No | 4200.0 | 4200.0 | 1.0 | False | None | None | False | None | False | 4200.0 | 0 |
3069900 | 104668 | None | code107 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. GI strip , 25x3mm P | m | 92.96 | 92.96 | 5.0 | False | None | None | False | None | False | 464.8 | 0 |
3069901 | 104668 | None | code108 | 600x600x3mm GI Plate | Each | 936.32 | 936.32 | 1.0 | False | None | None | False | None | False | 936.32 | 0 |
3069902 | 104668 | None | code109 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary | m | 118.72 | 118.72 | 50.0 | False | None | None | False | None | False | 5936.0 | 0 |
3069903 | 104668 | None | code110 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS.694:confirming to latest amendments. PWD Electrical SoR 2021.2022 (Item No. 2.3) | m | 356.16 | 356.16 | 50.0 | False | None | None | False | None | False | 17808.0 | 0 |
3069904 | 104668 | None | code111 | Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 . 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 . 2. | Each | 10269.28 | 10269.28 | 1.0 | False | None | None | False | None | False | 10269.28 | 0 |
3069905 | 104668 | None | code112 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. | Each | 273.28 | 273.28 | 1.0 | False | None | None | False | None | False | 273.28 | 0 |
3069906 | 104668 | None | code113 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross.3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. | Each | 585.76 | 585.76 | 2.0 | False | None | None | False | None | False | 1171.52 | 0 |
3069907 | 104668 | None | code114 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit/ casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. | Point | 309.12 | 309.12 | 1.0 | False | None | None | False | None | False | 309.12 | 0 |
3069908 | 104668 | None | code115 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS.694:1990 & confirming to GTP of GROUP .A. | m | 44.8 | 44.8 | 50.0 | False | None | None | False | None | False | 2240.0 | 0 |
3069909 | 104668 | None | code116 | Supplying of feet . PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70percentage lumen maintenance with CRI Greater than 80. Power Input: 220.240V @ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. | Each | 828.8 | 828.8 | 2.0 | False | None | None | False | None | False | 1657.6 | 0 |
3069910 | 104668 | None | code117 | Fabricating, supplying and erection of ... ms long hot dip Galvanized Octagonal hot dip Pole with BSEN 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for .......m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom ..... mm , top.... mm with 3 mm thick, suitable base plate and 4Nos of ..... long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM.A123 and 153 etc., (excluding foundation) as per drawing appended. | Each | 9935.52 | 9935.52 | 2.0 | False | None | None | False | None | False | 19871.04 | 0 |
3069911 | 104668 | None | code118 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70percentage, CCT Greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire Greater than IK08. Power Factor Greater than0.9 with mains, Surge Protection. Min 5KV along with Over voltage/ Overload, short circuit/ miss.wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ....... W System Power consumption. LED EfficiencyGreater than 1301m/w, nominal CRI Greater than75. Luminaire manufacturer should have in. house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ PWD Electrical SoR 2021.22 | No | 8276.8 | 8276.8 | 2.0 | False | None | None | False | None | False | 16553.6 | 0 |
3069912 | 104668 | None | code119 | Procuring and installation of 0.5 HP pump for the maintenance of modules as specified by the EIC | No | 9240.0 | 9240.0 | 1.0 | False | None | None | False | None | False | 9240.0 | 0 |
3069913 | 104668 | None | code120 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work | Cum | 81.76 | 81.76 | 2.565 | False | None | None | False | None | False | 209.7144 | 0 |
3069914 | 104668 | None | code121 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm and down size graded crushed coarse aggregates | Cum | 6220.48 | 6220.48 | 1.7812 | False | None | None | False | None | False | 11079.918976 | 0 |
3069915 | 104668 | None | code122 | Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete | Kg | 107.52 | 107.52 | 2831.0 | False | None | None | False | None | False | 304389.12 | 0 |
3069916 | 104668 | None | code123 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer.in.charge. (Made of G.I. wire of dia 4 mm | Sqm | 757.12 | 757.12 | 375.0 | False | None | None | False | None | False | 283920.0 | 0 |
3069917 | 104668 | None | code124 | Providng and fixing Locking arrangements. | Each | 728.0 | 728.0 | 2.0 | False | None | None | False | None | False | 1456.0 | 0 |
3069918 | 104668 | None | code125 | NON SR.Items. Procuring, fabricating and supplying a stainless steel screen as per the drawing provided. 10 mm thick SS 304 bars, 20 mm wide, with a boundary and two handles | Each | 6500.0 | 6500.0 | 12.0 | False | None | None | False | None | False | 78000.0 | 0 |
3069919 | 104668 | None | code126 | Procuring and Planting rhizomes such as canna indica, water lily, vertiver, etc at an interval of 0.5 m | Nos | 98.56 | 98.56 | 300.0 | False | None | None | False | None | False | 29568.0 | 0 |
3069920 | 104668 | None | code127 | Procuring and lowering the cinder ballast in the AF chamber gently after washing for dust | Cum | 841.37 | 841.37 | 1.26 | False | None | None | False | None | False | 1060.1262 | 0 |
3069921 | 104668 | None | code128 | Providing and planting common reeds or other rhizome eg. Vetiver, Colocasia, Lily, Cana Indica, Typha, etc. | Sqm | 98.56 | 98.56 | 100.0 | False | None | None | False | None | False | 9856.0 | 0 |