3053603 | 103400 | None | code01 | Earth work in surface excavation for stripping, seating of bund, Road way by manual means for owering & levelling the ground for all works other than foundation & depth in Ordinary rock and soft rock upto 300mm depth as per drawing and technical specifications, including setting out, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5m including cost of labour, tools, usage& other appurtenances requiredto complete the work. (P.No. 5 I.No.1.2 PWD CM SR 21-22) | Cum | 506.24 | 506.24 | 52.8 | False | None | None | False | None | False | 26729.472 | 0 |
3053604 | 103400 | None | code02 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work In all kinds of soil (P.No. 6 I.No.1.6 PWD CM SR 21-22) | Cum | 526.4 | 526.4 | 136.89 | False | None | None | False | None | False | 72058.896 | 0 |
3053605 | 103400 | None | code03 | Providing and Filling in foundation with granite / trap broken metal 100mm. and down size, with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift. complete as per specifications.(P.No. 151 I.No.6.4 PWD CM SR 21-22 Vol II Corrgdm I). | Cum | 2868.32 | 2868.32 | 12.3 | False | None | None | False | None | False | 35280.336 | 0 |
3053606 | 103400 | None | code04 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates (PWD CSR 2021-22, Volume-I It No 2.1.3 Page No 15) | Cum | 6220.48 | 6220.48 | 19.35 | False | None | None | False | None | False | 120366.288 | 0 |
3053607 | 103400 | None | code05 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M 25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR 2021-22, Volume-I It No 2.2.2.1 Page No 15) | Cum | 7232.2 | 7232.2 | 20.65 | False | None | None | False | None | False | 149344.93 | 0 |
3053608 | 103400 | None | code06 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR 2021-22, Volume-I It No 2.4.3 Page No 17) | Cum | 10066.56 | 10066.56 | 8.23 | False | None | None | False | None | False | 82847.7888 | 0 |
3053609 | 103400 | None | code07 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR 2021-22, Volume-I It No 2.5.2 Page No 17) | Cum | 11778.14 | 11778.14 | 12.66 | False | None | None | False | None | False | 149111.2524 | 0 |
3053610 | 103400 | None | code08 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR 2021-22, Volume-I It No 2.5.2 Page No 17) | Cum | 11085.31 | 11085.31 | 13.32 | False | None | None | False | None | False | 147656.3292 | 0 |
3053611 | 103400 | None | code09 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR 2021-22, Volume-I It No 2.5.2 Page No 17) | Cum | 10046.06 | 10046.06 | 1.94 | False | None | None | False | None | False | 19489.3564 | 0 |
3053612 | 103400 | None | code10 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M 25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR 2021-22, Volume-I It No 2.5.2 Page No 17) | Cum | 11085.31 | 11085.31 | 35.44 | False | None | None | False | None | False | 392863.3864 | 0 |
3053613 | 103400 | None | code11 | Providing Cement mortar 1:3 (1 cement : 3 fine sand) including cost of all materials, labour and usage charges of machinery complete as per the direction of engineer incharge of work. (PWD CSR 2021-22, Volume-I It No 2.5.1 Page No 17) | Cum | 6022.24 | 6022.24 | 5.94 | False | None | None | False | None | False | 35772.1056 | 0 |
3053614 | 103400 | None | code12 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) (PWD CSR 2021-22, Volume-II It No 11.32 Page No 84) | Kgs | 103.04 | 103.04 | 8120.96 | False | None | None | False | None | False | 836783.7184 | 0 |
3053615 | 103400 | None | code13 | Providing and constructing Laterite Size stone masonry including cost and conveyance of all materials etc., curing complete as per specification IS 3620/1979 having compressive strenght not less than 3.50N/mm2 for saturated dry samples For foundation in CM 1:6(PWD CSR 2021-22, Volume-II It No 6.35 Page No 17 I st Corrgdm) | Cum | 6265.28 | 6265.28 | 26.83 | False | None | None | False | None | False | 168097.4624 | 0 |
3053616 | 103400 | None | code14 | Providing and constructing Laterite Size stone masonry including cost and conveyance of all materials etc., curing complete as per specification IS 3620/1979 having compressive strenght not less than 3.50N/mm2 for saturated dry samples For Basement in CM 1:6(PWD CSR 2021-22, Volume-II It No 6.36 Page No 17 I st Corrgdm) | Cum | 6328.0 | 6328.0 | 15.23 | False | None | None | False | None | False | 96375.44 | 0 |
3053617 | 103400 | None | code15 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (PWD CSR 2021-22, Volume-I It No 1.9 Page No 35) | Cum | 228.48 | 228.48 | 62.45 | False | None | None | False | None | False | 14268.576 | 0 |
3053618 | 103400 | None | code16 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. (PWD CSR 2021-22, Volume-I It No 4.1 Page No 5) | Sqm | 106.4 | 106.4 | 178.43 | False | None | None | False | None | False | 18984.952 | 0 |
3053619 | 103400 | None | code17 | Providing and Filling in foundation with granite / trap broken metal 100mm. and down size, with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift. complete as per specifications.(P.No. 151 I.No.6.4 PWD CM SR 21-22 Vol II Corrgdm I). | Cum | 2868.32 | 2868.32 | 22.98 | False | None | None | False | None | False | 65913.9936 | 0 |
3053620 | 103400 | None | code18 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR 2021-22, Volume-I It No 2.1.4 Page No15) | Cum | 6415.36 | 6415.36 | 36.49 | False | None | None | False | None | False | 234096.4864 | 0 |
3053621 | 103400 | None | code19 | Providing and constructing Laterite Size stone masonry including cost and conveyance of all materials etc., curing complete as per specification IS 3620/1979 having compressive strenght not less than 3.50N/mm2 for saturated dry samples For Super Structure in CM 1:6 (PWD CSR 2021-22, Volume-II It No 6.37 Page No 17 I st Corrgdm) | Cum | 6611.36 | 6611.36 | 47.3 | False | None | None | False | None | False | 312717.328 | 0 |
3053622 | 103400 | None | code20 | Providing Honne wood frames of doors, windows, clerestory windows,ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications(PWD CSR 2021-22, Volume-II It No 12.11 Page No 99) | Cum | 101240.16 | 101240.16 | 0.28 | False | None | None | False | None | False | 28347.2448 | 0 |
3053623 | 103400 | None | code21 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.(PWD CSR 2021-22 It No 11.34B Page,No.85) | Kgs | 160.16 | 160.16 | 1152.14 | False | None | None | False | None | False | 184526.7424 | 0 |
3053624 | 103400 | None | code22 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD CSR 2021-22, Volume-II It No 8.1.1 Page No 41) | Sqm | 238.56 | 238.56 | 277.48 | False | None | None | False | None | False | 66195.6288 | 0 |
3053625 | 103400 | None | code23 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD CSR 2021-22, Volume-II It No 8.7 Page No 42) | Sqm | 348.32 | 348.32 | 263.15 | False | None | None | False | None | False | 91660.408 | 0 |
3053626 | 103400 | None | code24 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(PWD CSR 2021-22, Volume-II It No 8.9 Page No 42) | Sqm | 360.64 | 360.64 | 226.16 | False | None | None | False | None | False | 81562.3424 | 0 |
3053627 | 103400 | None | code25 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.(PWD CSR 2021-22, Volume-II It No 9.17.2 Page No 61) | Sqm | 1234.24 | 1234.24 | 229.72 | False | None | None | False | None | False | 283529.6128 | 0 |
3053628 | 103400 | None | code26 | Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures )(PWD CSR 2021-22, Volume-II It No 12.15 Page No 100) | Sqm | 5682.88 | 5682.88 | 11.52 | False | None | None | False | None | False | 65466.7776 | 0 |
3053629 | 103400 | None | code27 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete (PWD CSR 2021-22, Volume-II It No 12.58 Page No 106) | Nos | 122.08 | 122.08 | 4.0 | False | None | None | False | None | False | 488.32 | 0 |
3053630 | 103400 | None | code28 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete(PWD CSR 2021-22, Volume-II It No 12.63 Page No 106) | Nos | 124.32 | 124.32 | 8.0 | False | None | None | False | None | False | 994.56 | 0 |
3053631 | 103400 | None | code29 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.(PWD CSR 2021-22, Volume-II It No 12.60 Page No 106) | Nos | 931.84 | 931.84 | 4.0 | False | None | None | False | None | False | 3727.36 | 0 |
3053632 | 103400 | None | code30 | Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete.(PWD CSR 2021-22, Volume-II It No 12.61 Page No 106) | Nos | 695.52 | 695.52 | 4.0 | False | None | None | False | None | False | 2782.08 | 0 |
3053633 | 103400 | None | code31 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete.(PWD CSR 2021-22, Volume-II It No 12.75 Page No 108) | Nos | 225.12 | 225.12 | 12.0 | False | None | None | False | None | False | 2701.44 | 0 |
3053634 | 103400 | None | code32 | Providing and fixing of 2 track x 2 panel sliding windows made out of multi chambered UPVC Matching to RAL 9016 sections and with minimum TiO2 Titanium Dioxide at 6PHR with TPE Thermo Plastic Elastomer and lead free gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through out the window frame The outer frame having a overall size of 60mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm X 58mm with GI reinforcement of 1mm for the frame and 1.5 mm for the sash Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24mm Windows shall be provided with 5mm plain float glass standard hardware and single point locking system with touch lock Wall thickness of frame and sash shall be of 2-2.5 mm Maximum possible size 1819mm x 1819mm The cost is inclusive of all fixtures and separate charges for minor T and P's shall not be made | Sqm | 6543.04 | 6543.04 | 14.4 | False | None | None | False | None | False | 94219.776 | 0 |
3053635 | 103400 | None | code33 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc.complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge(PWD CSR 2021-22, Volume-I It No 11.16.2 Page No 81) | Kgs | 152.32 | 152.32 | 107.18 | False | None | None | False | None | False | 16325.6576 | 0 |
3053636 | 103400 | None | code34 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(PWD CSR 2021-22, Volume-II It No 8.51 Page No 50) | Sqm | 92.96 | 92.96 | 562.39 | False | None | None | False | None | False | 52279.7744 | 0 |
3053637 | 103400 | None | code35 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per anufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(PWD CSR 2021-22, Volume-II It No 8.33.1 Page No 46) | Sqm | 132.16 | 132.16 | 766.79 | False | None | None | False | None | False | 101338.9664 | 0 |
3053638 | 103400 | None | code36 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD CSR 2021-22, Volume-II It No 8.33.3 Page No 46) | Sqm | 118.72 | 118.72 | 14.4 | False | None | None | False | None | False | 1709.568 | 0 |
3053639 | 103400 | None | code37 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning
oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD CSR 2021-22, Volume-II It No 8.33.2 Page No 45) | Sqm | 118.72 | 118.72 | 29.95 | False | None | None | False | None | False | 3555.664 | 0 |
3053640 | 103400 | None | code38 | Providing wall black boards in CM 1:3 with two coats of black paint including finishing etc., complete (P.No. 268, I.No. 37.30 of P.W.D.S.R.2018-19) | Sqm | 925.75 | 925.75 | 4.0 | False | None | None | False | None | False | 3703.0 | 0 |
3053641 | 103400 | None | code39 | Open Conduit System : Supplying heavy gauge PVC conduit pipe 25 mm dia 2 mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be lied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. 1.1.2 19mm dia 2mm thick. 19mm dia 2mm thick. (PWD CM SR P.No. 1 I.No. 1.1.1 2022-23) | Mtr | 68.0 | 68.0 | 10.0 | False | None | None | False | None | False | 680.0 | 0 |
3053642 | 103400 | None | code40 | Concealed Conduit System : Supplying heavy gauge PVC conduit pipe 25 mm dia 2 mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be lied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. 1.2.2 19 mm dia 2mm thick.19mm dia 2mm thick. (PWD CM SR P.No. 1 I.No. 1.2.1 2022-23) | Mtr | 61.0 | 61.0 | 300.0 | False | None | None | False | None | False | 18300.0 | 0 |
3053643 | 103400 | None | code41 | Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.,1.4.7) 200x200x65mm. | Nos | 335.0 | 335.0 | 4.0 | False | None | None | False | None | False | 1340.0 | 0 |
3053644 | 103400 | None | code42 | Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc., 1.4.2) 100x75x65mm. | Nos | 112.0 | 112.0 | 4.0 | False | None | None | False | None | False | 448.0 | 0 |
3053645 | 103400 | None | code43 | Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc., 1.4.1) 75x75x65mm. | Nos | 100.0 | 100.0 | 4.0 | False | None | None | False | None | False | 400.0 | 0 |
3053646 | 103400 | None | code44 | 1.5 Supplying and fixing PVC/metal conduit Deep junction box (PWD CM SR P.No. 1 I.No. 1.5.1 2022-23) | Nos | 49.0 | 49.0 | 12.0 | False | None | None | False | None | False | 588.0 | 0 |
3053647 | 103400 | None | code45 | Extra for Groove cutting in brick wall/cc floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. 1.7.1) upto 50mm conduit in brick wall (PWD CM SR P.No. 2 I.No. 1.7.1 2022-23) | Mtr | 26.0 | 26.0 | 130.0 | False | None | None | False | None | False | 3380.0 | 0 |
3053648 | 103400 | None | code46 | Supplying and wiring adopting loope system in existing PVC Conduit / casing capping using 1100v grade, COPPER conductor flexible muitistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming ot the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A Short point upto 3Mtr from tapping point to out let via switch. (PWD CM SR P.No. 2 I.No. 2.1.1 2022-23) | Nos | 276.0 | 276.0 | 10.0 | False | None | None | False | None | False | 2760.0 | 0 |
3053649 | 103400 | None | code47 | Supplying and wiring adopting loope system in existing PVC Conduit / casing capping using 1100v grade, COPPER conductor flexible muitistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming ot the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch. (PWD CM SR P.No. 2 I.No. 2.1.2 2022-23) | Nos | 386.0 | 386.0 | 10.0 | False | None | None | False | None | False | 3860.0 | 0 |
3053650 | 103400 | None | code48 | Supplying and wiring adopting loope system in existing PVC Conduit / casing capping using 1100v grade, COPPER conductor flexible muitistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming ot the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A Long point above 6Mtr upto 10Mtr from tapping point to out let via switch. (PWD CM SR P.No. 2 I.No. 2.1.3 2022-23) | Nos | 567.0 | 567.0 | 14.0 | False | None | None | False | None | False | 7938.0 | 0 |
3053651 | 103400 | None | code49 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps switch one way (PWD CM SR P.No. 5 I.No. 3.7.1 2022-23) | Nos | 88.0 | 88.0 | 44.0 | False | None | None | False | None | False | 3872.0 | 0 |
3053652 | 103400 | None | code50 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Socket (PWD CM SR P.No. 5 I.No. 3.7.3 2022-23) | Nos | 162.0 | 162.0 | 12.0 | False | None | None | False | None | False | 1944.0 | 0 |
3053653 | 103400 | None | code51 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped fan regulator (PWD CM SR P.No. 5 I.No. 3.7.4 2022-23) | Nos | 313.0 | 313.0 | 12.0 | False | None | None | False | None | False | 3756.0 | 0 |
3053654 | 103400 | None | code52 | Supplying 2 to 4 way plastic Gang Box and fixing usig necessary wooden/rawl/phill plugs and screws. (PWD CM SR P.No. 5 I.No. 3.12.2 2022-23) | Nos | 29.0 | 29.0 | 30.0 | False | None | None | False | None | False | 870.0 | 0 |
3053655 | 103400 | None | code53 | Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board. GROUP A 6Amps Bakelite ceiling rose (P.No. 18 I.No. 3.14.5) | Nos | 63.0 | 63.0 | 30.0 | False | None | None | False | None | False | 1890.0 | 0 |
3053656 | 103400 | None | code54 | upplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board. GROUP A 6Amps lamp holder (P.No. 18 I.No.3.14.6) | Nos | 63.0 | 63.0 | 30.0 | False | None | None | False | None | False | 1890.0 | 0 |
3053657 | 103400 | None | code55 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 Sqmm (PWD CM SR P.No. 2 I.No. 2.3.2 2022-23) | Mtr | 26.0 | 26.0 | 500.0 | False | None | None | False | None | False | 13000.0 | 0 |
3053658 | 103400 | None | code56 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.00 Sqmm (PWD CM SR P.No. 2 I.No. 2.3.1 2022-23) | Mtr | 18.0 | 18.0 | 600.0 | False | None | None | False | None | False | 10800.0 | 0 |
3053659 | 103400 | None | code57 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.50 Sqmm (PWD CM SR P.No. 2 I.No. 2.3.3 2022-23) | Mtr | 40.0 | 40.0 | 300.0 | False | None | None | False | None | False | 12000.0 | 0 |
3053660 | 103400 | None | code58 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.6 Way (PWD CM SR P.No. 5 I.No. 3.3.3 2022-23) | Nos | 149.0 | 149.0 | 4.0 | False | None | None | False | None | False | 596.0 | 0 |
3053661 | 103400 | None | code59 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with re61 to 3 Module (PWD CM SR P.No. 5 I.No. 3.5.3 2022-23) | Nos | 244.0 | 244.0 | 4.0 | False | None | None | False | None | False | 976.0 | 0 |
3053662 | 103400 | None | code60 | Supplying of feet PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours and 70 percent lumen maintenance with CRI more den 80 Power Input 220-240V at 50/60Hz and Power factor more den 0.9 along with CE approved 2 years Warranty against any manufacturing defect working under standard electrical condition LED light fighting 2x 4' 20 /22 w | Nos | 1197.0 | 1197.0 | 24.0 | False | None | None | False | None | False | 28728.0 | 0 |
3053663 | 103400 | None | code61 | Supplying capacitor type ceilling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball boaring system. Regular model (PWD CM SR P.No.224 I.No. 6.3.2 2022-23) | Nos | 2170.0 | 2170.0 | 12.0 | False | None | None | False | None | False | 26040.0 | 0 |
3053664 | 103400 | None | code62 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. ) Regular model (PWD CM SR P.No.224 I.No. 13.11 2022-23) | Nos | 281.0 | 281.0 | 12.0 | False | None | None | False | None | False | 3372.0 | 0 |
3053665 | 103400 | None | code63 | Fixing all types and all capacities of 1'x4' / 2'x2' LED Light fittings indoor on the wall / ceiling / rafters / girders with necessary supporting frame, using 2310.0076" twin twistedPVC insulated wires, required Nos of round blocks and clA..(PWD CM SR P.No.224 I.No. 13.19 2022-23) | Nos | 486.0 | 486.0 | 24.0 | False | None | None | False | None | False | 11664.0 | 0 |
3053666 | 103400 | None | code64 | Chemical earthing for grounding, conduits, IC out outs & other equipments on the meter board by using copper bonded / SS rod with earth enhancing backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 10ft copper bonded rod with backfill compound. .(PWD CM SR P.No.224 I.No. 6.19.3 2022-23) | Nos | 7260.0 | 7260.0 | 2.0 | False | None | None | False | None | False | 14520.0 | 0 |