tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1710343760000 | 0 | None | None | Buildings | Construction Ramp and Toilet for Disabled Persons in Various Offices in Kalagi Town. | 899789.94 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3053070 | 103381 | None | CODE01 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.(ii) By Mechanical Means using DozerB In area of thorny jungle
| Sqm | 412.65 | 412.65 | 0.25 | False | None | None | False | None | False | 103.1625 | 0 | 3053071 | 103381 | None | CODE02 | Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, trutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.
| Cum | 95.55 | 95.55 | 4.32 | False | None | None | False | None | False | 412.776 | 0 | 3053072 | 103381 | None | CODE03 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.Depth exceeding 1.5m, but not exceeding 3 m
| Cum | 508.2 | 508.2 | 25.38 | False | None | None | False | None | False | 12898.116 | 0 | 3053073 | 103381 | None | CODE04 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates
| Cum | 6288.45 | 6288.45 | 3.01 | False | None | None | False | None | False | 18928.2345 | 0 | 3053074 | 103381 | None | CODE05 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 7170.28 | 7170.28 | 3.558 | False | None | None | False | None | False | 25511.85624 | 0 | 3053075 | 103381 | None | CODE06 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) 2.3.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 11566.8 | 11566.8 | 0.7632 | False | None | None | False | None | False | 8827.78176 | 0 | 3053076 | 103381 | None | CODE07 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) 2.3.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 10206.0 | 10206.0 | 0.792 | False | None | None | False | None | False | 8083.152 | 0 | 3053077 | 103381 | None | CODE08 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)
| Cum | 6708.45 | 6708.45 | 4.752 | False | None | None | False | None | False | 31878.5544 | 0 | 3053078 | 103381 | None | CODE09 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge.
| Sqm | 267.75 | 267.75 | 7.92 | False | None | None | False | None | False | 2120.58 | 0 | 3053079 | 103381 | None | CODE10 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
| Cum | 279.3 | 279.3 | 21.146 | False | None | None | False | None | False | 5906.0778 | 0 | 3053080 | 103381 | None | CODE11 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS
2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications."
| Sqm | 1375.5 | 1375.5 | 22.14 | False | None | None | False | None | False | 30453.57 | 0 | 3053081 | 103381 | None | CODE12 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having lock density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.
| Sqm | 1159.2 | 1159.2 | 9.48 | False | None | None | False | None | False | 10989.216 | 0 | 3053082 | 103381 | None | CODE13 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates
| Cum | 6288.45 | 6288.45 | 0.045 | False | None | None | False | None | False | 282.98025 | 0 | 3053083 | 103381 | None | CODE14 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super lasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 11138.4 | 11138.4 | 0.972 | False | None | None | False | None | False | 10826.5248 | 0 | 3053084 | 103381 | None | CODE15 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super lasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 10442.25 | 10442.25 | 1.53 | False | None | None | False | None | False | 15976.6425 | 0 | 3053085 | 103381 | None | CODE16 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 253.05 | 253.05 | 12.24 | False | None | None | False | None | False | 3097.332 | 0 | 3053086 | 103381 | None | CODE17 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 10442.25 | 10442.25 | 0.864 | False | None | None | False | None | False | 9022.104 | 0 | 3053087 | 103381 | None | CODE18 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per pecification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.
| Sqm | 857.85 | 857.85 | 10.8 | False | None | None | False | None | False | 9264.78 | 0 | 3053088 | 103381 | None | CODE19 | Providing and fixing factory made UPVC Door Frame made of UPVC extruded sections having an overall dimension as below (tolerance +/- 1mm ) with wall thickness 2.00mm (+/- 2mm), corners of the door frames to be jointed with galvanised brackets and stainless steel screws,joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanised MS Tube of size 19mm X 19mm and 1mm (+/-1mm) wall thickness and 3 Nos stainless steel hinges fixed to the frame complete as per manufacturer specification and direction of Engineer-in-charge.
| Sqm | 207.9 | 207.9 | 21.0 | False | None | None | False | None | False | 4365.9 | 0 | 3053089 | 103381 | None | CODE20 | Providing and fixing of openable Door made out of multi chambered UPVC (matching to RAL-9016) sections and with minimum Ti02 (Titanium Doxide) at 6PHR with TPV (Thermo Plastic Vulcanised) and lead free with gasket -grey color having isolated drainage and reinforced with Galvanised Iron profile through out the openable frame. The frame having overall size of 60mm X 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm X 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm X 34mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & multi point locking system with handle. Wall thickness of frame and sash shall be of 2mm-2.50mm. Maximum possible size - 900mm X 2400mm. (The cost is inclusive of all fixtures and separate charge for minor T&P's shall not be made)
| Sqm | 6557.25 | 6557.25 | 10.71 | False | None | None | False | None | False | 70228.1475 | 0 | 3053090 | 103381 | None | CODE21 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.
| Kg | 192.15 | 192.15 | 28.35 | False | None | None | False | None | False | 5447.4525 | 0 | 3053091 | 103381 | None | CODE22 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement ortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever equired smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 389.55 | 389.55 | 24.93 | False | None | None | False | None | False | 9711.4815 | 0 | 3053092 | 103381 | None | CODE23 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, uring complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 253.05 | 253.05 | 40.08 | False | None | None | False | None | False | 10142.244 | 0 | 3053093 | 103381 | None | CODE24 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm
| Sqm | 1233.75 | 1233.75 | 8.32 | False | None | None | False | None | False | 10264.8 | 0 | 3053094 | 103381 | None | CODE25 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement ortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete.
| Sqm | 1161.3 | 1161.3 | 21.38 | False | None | None | False | None | False | 24828.594 | 0 | 3053095 | 103381 | None | CODE26 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per pecifications and as per directions of Engineer in charge.
| Sqm | 105.0 | 105.0 | 37.17 | False | None | None | False | None | False | 3902.85 | 0 | 3053096 | 103381 | None | CODE27 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per pecifications and as per directions of Engineer-in-charge.
| Sqm | 133.35 | 133.35 | 24.93 | False | None | None | False | None | False | 3324.4155 | 0 | 3053097 | 103381 | None | CODE28 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to move all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 186.9 | 186.9 | 24.93 | False | None | None | False | None | False | 4659.417 | 0 | 3053098 | 103381 | None | CODE29 | Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineerin-
charge. "
| Sqm | 27.3 | 27.3 | 24.93 | False | None | None | False | None | False | 680.589 | 0 | 3053099 | 103381 | None | CODE30 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter ncluding preparing the surface even and sand paper smooth, cost of materials, labour complete as per pecifications and as per directions of Engineer-in-charge.
| Sqm | 120.75 | 120.75 | 2.7 | False | None | None | False | None | False | 326.025 | 0 | 3053100 | 103381 | None | CODE31 | Supplying, Fitting and Placing TMT Fe 500 & above Reinforcement in Foundation / Substructure Superstructure complete as per Drawing and Technical Specifications.
| Tonne | 82961.55 | 82961.55 | 0.7712 | False | None | None | False | None | False | 63979.94736 | 0 | 3053101 | 103381 | None | CODE32 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other ppurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) 2.1.4 Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse
aggregates"
| Cum | 6527.85 | 6527.85 | 1.188 | False | None | None | False | None | False | 7755.0858 | 0 | 3053102 | 103381 | None | CODE33 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the ngineerin- Charge.)
| Kg | 192.15 | 192.15 | 211.68 | False | None | None | False | None | False | 40674.312 | 0 | 3053103 | 103381 | None | CODE34 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge
| Sqm | 333.9 | 333.9 | 10.71 | False | None | None | False | None | False | 3576.069 | 0 | 3053104 | 103381 | None | CODE35 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per anufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.12.55.2 -do- with one side prelam
| Cum | 2142.0 | 2142.0 | 10.71 | False | None | None | False | None | False | 22940.82 | 0 | 3053105 | 103381 | None | CODE36 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter
| Mtr | 305.55 | 305.55 | 50.0 | False | None | None | False | None | False | 15277.5 | 0 | 3053106 | 103381 | None | 037 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, if c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipes
| Mtr | 397.95 | 397.95 | 20.0 | False | None | None | False | None | False | 7959.0 | 0 | 3053107 | 103381 | None | 038 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, if c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipes
| Mtr | 584.85 | 584.85 | 20.0 | False | None | None | False | None | False | 11697.0 | 0 | 3053108 | 103381 | None | 039 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required 14.2.1 W.C. pan with ISI marked white solid plastic seat and lid
| Each | 5079.9 | 5079.9 | 3.0 | False | None | None | False | None | False | 15239.7 | 0 | 3053109 | 103381 | None | 040 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 14.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
| Each | 3236.1 | 3236.1 | 2.0 | False | None | None | False | None | False | 6472.2 | 0 | 3053110 | 103381 | None | 041 | Providing and fixing brass stop cock of approved quality : 13.3.2 20 mm nominal bore
| Each | 320.25 | 320.25 | 5.0 | False | None | None | False | None | False | 1601.25 | 0 | 3053111 | 103381 | None | 042 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 13.5.3 25 mm nominal bore
| Each | 348.6 | 348.6 | 3.0 | False | None | None | False | None | False | 1045.8 | 0 | 3053112 | 103381 | None | 043 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base suooort for tank. | Ltr | 9.45 | 9.45 | 1000.0 | False | None | None | False | None | False | 9450.0 | 0 | 3053113 | 103381 | None | 044 | Providing and fixing unplasticised PVC connection pipe with brass unions : 45 cm length 13.8.2.1 15 mm nominal bore"
| Nos | 95.55 | 95.55 | 3.0 | False | None | None | False | None | False | 286.65 | 0 | 3053114 | 103381 | None | 045 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
| Nos | 1281.0 | 1281.0 | 2.0 | False | None | None | False | None | False | 2562.0 | 0 | 3053115 | 103381 | None | 046 | Providing and fixing 100 mm sand cast Iron grating for gully trap.
| Each | 49.35 | 49.35 | 2.0 | False | None | None | False | None | False | 98.7 | 0 | 3053116 | 103381 | None | 047 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth Page No.6 Item No. 1.5.1 KPWD. Volumn -1 DSR 2023-24
| Cum | 313.95 | 313.95 | 217.22 | False | None | None | False | None | False | 68196.219 | 0 | 3053117 | 103381 | None | 048 | Providing Brick work with common burnt clay machine moulded perforated bricks of class designation 3.5 in superstructure above plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) With Non modular bricks including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
| Cum | 8367.45 | 8367.45 | 1.24 | False | None | None | False | None | False | 10375.638 | 0 | 3053118 | 103381 | None | 049 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 404.25 | 404.25 | 18.96 | False | None | None | False | None | False | 7664.58 | 0 | 3053119 | 103381 | None | 050 | Providing and laying 100mm thick pre-cast cover slabs over drains & Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. itm.no 17.12 Page No.152 KPWD. Volumn -2 DSR 2023-24
| Sqm | 974.4 | 974.4 | 2.07 | False | None | None | False | None | False | 2017.008 | 0 | 3053120 | 103381 | None | 051 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe32 mm dia ( item no 14.28.2.1 ) page no 123 PWP. DSR 2023-24
| Each | 96.6 | 96.6 | 2.0 | False | None | None | False | None | False | 193.2 | 0 | 3053121 | 103381 | None | 052 | Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. etc. complete
(KPWD SR VOL V for the year 2023-24. I. No. 12.4 P.No. 140 )"
| Nos | 5552.4 | 5552.4 | 1.0 | False | None | None | False | None | False | 5552.4 | 0 | 3053122 | 103381 | None | 053 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 0 to 50 Mtrs
(KPWD SR VOL V for the year 2023-24. I. No. 12.1.1 P.No. 132 )"
| Rmtr | 388.5 | 388.5 | 50.0 | False | None | None | False | None | False | 19425.0 | 0 | 3053123 | 103381 | None | 054 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 50 to 100 Mtrs
(KPWD SR VOL V for the year 2023-24. I. No. 12.1.2 P.No. 132 )"
| Rmtr | 487.2 | 487.2 | 50.0 | False | None | None | False | None | False | 24360.0 | 0 | 3053124 | 103381 | None | 055 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 100 to 150 Mtrs
(KPWD SR VOL V for the year 2023-24. I. No. 12.1.3 P.No. 132 )"
| Rmtr | 517.65 | 517.65 | 10.0 | False | None | None | False | None | False | 5176.5 | 0 | 3053125 | 103381 | None | 056 | PVC pipes of 6 Kg/cm2 for 160mm
(KPWD SR VOL V for the year 2023-24. Sl No. 649 P.No. A44 )"
| Rmtr | 441.0 | 441.0 | 6.0 | False | None | None | False | None | False | 2646.0 | 0 | 3053126 | 103381 | None | 057 | PVC pipes of 6 Kg/cm2 for 110mm
(KPWD SR VOL V for the year 2023-24. Sl No. 647 P.No. A44 )"
| Rmtr | 267.75 | 267.75 | 110.0 | False | None | None | False | None | False | 29452.5 | 0 | 3053127 | 103381 | None | 058 | Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all Amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in Charge ( (PWD UGD and water supply SR 2023-24 Volume - V Item no.12.34 page no.143)
| Nos | 172.2 | 172.2 | 1.0 | False | None | None | False | None | False | 172.2 | 0 | 3053128 | 103381 | None | 059 | Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest ammendments 1.50 HP/1.1KW 20 STG (PWD UGD and water supply SR 2023-24 Volume - V Item no.13.7.7 page no.150)
| Each | 19128.9 | 19128.9 | 1.0 | False | None | None | False | None | False | 19128.9 | 0 | 3053129 | 103381 | None | 060 | Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. (PWD UGD and water supply SR 2023-24 Volume - V Item no.13.31 page no.155)
| Mtr | 42.0 | 42.0 | 110.0 | False | None | None | False | None | False | 4620.0 | 0 | 3053130 | 103381 | None | 061 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. (PWD UGD and water supply SR 2023-24 Volume - V Item no.13.32 page no.156)
| Job | 6825.0 | 6825.0 | 1.0 | False | None | None | False | None | False | 6825.0 | 0 | 3053131 | 103381 | None | 062 | Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x6 Sqm. (PWD UGD and water supply SR 2023-24 Volume - V Item no.13.22.4 page no.154)
| Rmtr | 194.25 | 194.25 | 115.0 | False | None | None | False | None | False | 22338.75 | 0 | 3053132 | 103381 | None | 063 | Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0 (PWD UGD and water supply SR 2023-24 Volume - V Item no.9.1.1 page no.95)
| Rmtr | 198.45 | 198.45 | 105.0 | False | None | None | False | None | False | 20837.25 | 0 | 3053133 | 103381 | None | 064 | Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments (PWD UGD and water supply SR 2023-24 Volume - V Item no.13.25.2 page no.154)
| Nos | 1627.5 | 1627.5 | 1.0 | False | None | None | False | None | False | 1627.5 | 0 | 3053134 | 103381 | None | 065 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter
2) S-D- Star Delta Starter etc. complete.Upto 3 HP pumps (PWD UGD and water supply SR 2023-24 Volume - V Item no.13.24.1 page no.155)"
| Each | 7875.0 | 7875.0 | 1.0 | False | None | None | False | None | False | 7875.0 | 0 | 3053135 | 103381 | None | 066 | Labour charges for erection of outdoor type panel board and meter board units with all necessary materials and labour, tools and equipments including providing cement concrete foundation bed etc., complete as per specification, with testing of as per instructions of engineer incharge of work. (PWD UGD and water supply SR 2023-24 Volume - V Item no.13.34 page no.156)
| Job | 1522.5 | 1522.5 | 1.0 | False | None | None | False | None | False | 1522.5 | 0 | 3053136 | 103381 | None | 067 | Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPTCL authorities and erection, electrification and commissioning of the same at the location of respective pump sets. (PWD UGD and water supply SR 2023-24 Volume - V Item no.13.25 page no.155)
| Kvar | 577.5 | 577.5 | 1.0 | False | None | None | False | None | False | 577.5 | 0 | 3053137 | 103381 | None | 068 | Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box. (PWD UGD and water supply SR 2023-24 Volume - V Item no.13.26 page no.155)
| Per 3 Poles | 1207.5 | 1207.5 | 1.0 | False | None | None | False | None | False | 1207.5 | 0 | 3053138 | 103381 | None | 069 | Labour charges for providing connection using insulated sheathed steel wire cable as per IS 1554/ 1988 with latest amendments from KPTCL pole to meter board unit, with all necessary materials ,tools and equipments,as per specificationswith testing of as per instructions of engineer incharge of work. 3.5x 16 sqmm (PWD UGD and water supply SR 2023-24 Volume - V Item no.13.35.2 page no.156)
| Per 3 Poles | 168.0 | 168.0 | 1.0 | False | None | None | False | None | False | 168.0 | 0 | 3053139 | 103381 | None | 070 | Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19/20mm dia 2mm thick.
| Mtr | 69.0 | 69.0 | 25.0 | False | None | None | False | None | False | 1725.0 | 0 | 3053140 | 103381 | None | 071 | Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25mm dia 2mm thick.
| Mtr | 81.0 | 81.0 | 25.0 | False | None | None | False | None | False | 2025.0 | 0 | 3053141 | 103381 | None | 072 | Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 32mm dia 2.5mm thick.
| Mtr | 106.0 | 106.0 | 20.0 | False | None | None | False | None | False | 2120.0 | 0 | 3053142 | 103381 | None | 073 | Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19/20mm dia 2mm thick
| Mtr | 68.0 | 68.0 | 20.0 | False | None | None | False | None | False | 1360.0 | 0 | 3053143 | 103381 | None | 074 | Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25mm dia 2mm thick
| Mtr | 79.0 | 79.0 | 25.0 | False | None | None | False | None | False | 1975.0 | 0 | 3053144 | 103381 | None | 076 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, screws at an interval of 300mm …. etc. as required.25mm
| Mtr | 99.0 | 99.0 | 25.0 | False | None | None | False | None | False | 2475.0 | 0 | 3053145 | 103381 | None | 077 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, screws at an interval of 300mm …. etc. as required.25mm
| Mtr | 35.0 | 35.0 | 25.0 | False | None | None | False | None | False | 875.0 | 0 | 3053146 | 103381 | None | 078 | Supplying And Fixing Metal Fan Box with Round Hook
| Nos | 160.0 | 160.0 | 2.0 | False | None | None | False | None | False | 320.0 | 0 | 3053147 | 103381 | None | 079 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
2.3.2 1.5 mm2 "
| Mtr | 26.0 | 26.0 | 25.0 | False | None | None | False | None | False | 650.0 | 0 | 3053148 | 103381 | None | 080 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.3.3 2.5 mm2
| Mtr | 42.0 | 42.0 | 25.0 | False | None | None | False | None | False | 1050.0 | 0 | 3053149 | 103381 | None | 081 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.3.4 4 mm2
| Mtr | 63.0 | 63.0 | 25.0 | False | None | None | False | None | False | 1575.0 | 0 | 3053150 | 103381 | None | 082 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.3.5 6 mm2
| Mtr | 92.0 | 92.0 | 25.0 | False | None | None | False | None | False | 2300.0 | 0 | 3053151 | 103381 | None | 083 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 2.3.6 10 mm2
| Mtr | 167.0 | 167.0 | 25.0 | False | None | None | False | None | False | 4175.0 | 0 | 3053152 | 103381 | None | 084 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.1 1-3 Way
| Each | 138.0 | 138.0 | 1.0 | False | None | None | False | None | False | 138.0 | 0 | 3053153 | 103381 | None | 085 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.3 6 Way
| Each | 177.0 | 177.0 | 1.0 | False | None | None | False | None | False | 177.0 | 0 | 3053154 | 103381 | None | 086 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.4 8 Way
| Each | 220.0 | 220.0 | 1.0 | False | None | None | False | None | False | 220.0 | 0 | 3053155 | 103381 | None | 087 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.5 10-12 Way
| Each | 261.0 | 261.0 | 1.0 | False | None | None | False | None | False | 261.0 | 0 | 3053156 | 103381 | None | 088 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3.5.1 1 to 3 Module
| Each | 127.0 | 127.0 | 1.0 | False | None | None | False | None | False | 127.0 | 0 | 3053157 | 103381 | None | 089 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3.5.3 6 Module
| Each | 175.0 | 175.0 | 1.0 | False | None | None | False | None | False | 175.0 | 0 | 3053158 | 103381 | None | 090 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3.5.4 8 Module
| Each | 234.0 | 234.0 | 1.0 | False | None | None | False | None | False | 234.0 | 0 | 3053159 | 103381 | None | 091 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3.5.5 10-12 Module
| Each | 284.0 | 284.0 | 1.0 | False | None | None | False | None | False | 284.0 | 0 | 3053160 | 103381 | None | 093 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.1 6A One Way Switch
| Each | 102.0 | 102.0 | 1.0 | False | None | None | False | None | False | 102.0 | 0 | 3053161 | 103381 | None | 094 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.3 6A Three Way socket
| Each | 171.0 | 171.0 | 1.0 | False | None | None | False | None | False | 171.0 | 0 | 3053162 | 103381 | None | 095 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.8 16A One Way Switch
| Each | 177.0 | 177.0 | 1.0 | False | None | None | False | None | False | 177.0 | 0 | 3053163 | 103381 | None | 096 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. II - Double Door 5.18.6 4 Way SP & N
| Each | 1368.0 | 1368.0 | 1.0 | False | None | None | False | None | False | 1368.0 | 0 | 3053164 | 103381 | None | 097 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. II - Double Door 5.18.7 6 Way SP & N
| Each | 1102.0 | 1102.0 | 1.0 | False | None | None | False | None | False | 1102.0 | 0 | 3053165 | 103381 | None | 098 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 5.17.1 6-32 A SP
| Each | 415.0 | 415.0 | 1.0 | False | None | None | False | None | False | 415.0 | 0 | 3053166 | 103381 | None | 099 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 5.17.7 6-32 A TPN
| Each | 1717.0 | 1717.0 | 1.0 | False | None | None | False | None | False | 1717.0 | 0 | 3053167 | 103381 | None | 0100 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board. 5.20.3 32-40 A 4 pole
| Each | 2826.0 | 2826.0 | 1.0 | False | None | None | False | None | False | 2826.0 | 0 | 3053168 | 103381 | None | 101 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board. 5.20.4 63 A 4 pole
| Each | 3058.0 | 3058.0 | 1.0 | False | None | None | False | None | False | 3058.0 | 0 | 3053169 | 103381 | None | 102 | Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB ). The entire plug and socket shall be mounted in a thermoplastic / powder coated metal box & wired Completely. SP & N SP & N 5.45.2 20 A
| Each | 971.0 | 971.0 | 1.0 | False | None | None | False | None | False | 971.0 | 0 | 3053170 | 103381 | None | 103 | Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB ). The entire plug and socket shall be mounted in a thermoplastic / powder coated metal box & wired Completely. SP & N TP & N 5.45.3 20 A
| Each | 1340.0 | 1340.0 | 2.0 | False | None | None | False | None | False | 2680.0 | 0 | 3053171 | 103381 | None | 104 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 32.11 50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm) | Km | 178973.0 | 178973.0 | 0.02 | False | None | None | False | None | False | 3579.46 | 0 | 3053172 | 103381 | None | 105 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable
31.06 35 to 95 Sqmm"
| Km | 31139.0 | 31139.0 | 0.05 | False | None | None | False | None | False | 1556.95 | 0 | 3053173 | 103381 | None | 106 | Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. 29.03 In Hard Soil
| Cum | 389.0 | 389.0 | 6.0 | False | None | None | False | None | False | 2334.0 | 0 | 3053174 | 103381 | None | 107 | Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cm. Thickness including depositing of the surplus earth with a lead of 200 Mtr
| Cum | 58.0 | 58.0 | 6.0 | False | None | None | False | None | False | 348.0 | 0 | 3053175 | 103381 | None | 108 | LED Indoor Supplying of .feet -PVC Batten with integrated LED tube . W with high quality diffuser with Life of 25000 burning hours 70 lumen maintenance with CRI 80. Power Input: 220 240V 50/ 60Hz Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. 11.3.3 LED light fitting 1 4 - 36 40 W | Each | 1269.0 | 1269.0 | 3.0 | False | None | None | False | None | False | 3807.0 | 0 | 3053176 | 103381 | None | 109 | Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition. 11.5.3 LED square or round down light 15-18W
| Each | 1324.0 | 1324.0 | 4.0 | False | None | None | False | None | False | 5296.0 | 0 | 3053177 | 103381 | None | 108 | GESCOM DEPOSIT (LUMSUM AMOUNT)
| LS | 19000.0 | 19000.0 | 1.0 | False | None | None | False | None | False | 19000.0 | 0 |
| 1710343760000 | 0 | None | None | Buildings | 2 Construction of Town Panchayat Office Hall in Kalagi Town. | 2158116.76 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3053178 | 103382 | None | 001 | Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, trutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.
| Cum | 95.55 | 95.55 | 19.44 | False | None | None | False | None | False | 1857.492 | 0 | 3053179 | 103382 | None | 002 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.Depth exceeding 1.5m, but not exceeding 3 m
| Cum | 467.25 | 467.25 | 106.41 | False | None | None | False | None | False | 49720.0725 | 0 | 3053180 | 103382 | None | 003 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates
| Cum | 6288.45 | 6288.45 | 17.418 | False | None | None | False | None | False | 109532.2221 | 0 | 3053181 | 103382 | None | 004 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6971.11 | 6971.11 | 10.8 | False | None | None | False | None | False | 75287.988 | 0 | 3053182 | 103382 | None | 005 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) 2.3.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 7144.2 | 7144.2 | 6.0858 | False | None | None | False | None | False | 43478.17236 | 0 | 3053183 | 103382 | None | 006 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) 2.3.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 10206.0 | 10206.0 | 5.5224 | False | None | None | False | None | False | 56361.6144 | 0 | 3053184 | 103382 | None | 007 | Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)
| Cum | 6515.25 | 6515.25 | 33.1344 | False | None | None | False | None | False | 215878.8996 | 0 | 3053185 | 103382 | None | 008 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)
| Cum | 6708.45 | 6708.45 | 22.0896 | False | None | None | False | None | False | 148186.97712 | 0 | 3053186 | 103382 | None | 009 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge.
| Sqm | 267.75 | 267.75 | 36.816 | False | None | None | False | None | False | 9857.484 | 0 | 3053187 | 103382 | None | 010 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
| Cum | 279.3 | 279.3 | 92.142 | False | None | None | False | None | False | 25735.2606 | 0 | 3053188 | 103382 | None | 011 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.
| Sqm | 1375.5 | 1375.5 | 104.58 | False | None | None | False | None | False | 143849.79 | 0 | 3053189 | 103382 | None | 012 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having lock density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.
| Sqm | 1159.2 | 1159.2 | 60.03 | False | None | None | False | None | False | 69586.776 | 0 | 3053190 | 103382 | None | 013 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates
| Cum | 6288.45 | 6288.45 | 0.126 | False | None | None | False | None | False | 792.3447 | 0 | 3053191 | 103382 | None | 014 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super lasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 11138.4 | 11138.4 | 0.252 | False | None | None | False | None | False | 2806.8768 | 0 | 3053192 | 103382 | None | 015 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, uring and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 11138.4 | 11138.4 | 0.324 | False | None | None | False | None | False | 3608.8416 | 0 | 3053193 | 103382 | None | 016 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super lasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, uring and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm ominal size graded crushed coarse aggregates
| Cum | 11138.4 | 11138.4 | 5.5224 | False | None | None | False | None | False | 61510.70016 | 0 | 3053194 | 103382 | None | 017 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super lasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 10442.25 | 10442.25 | 15.9716 | False | None | None | False | None | False | 166779.4401 | 0 | 3053195 | 103382 | None | 018 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 253.05 | 253.05 | 127.7728 | False | None | None | False | None | False | 32332.90704 | 0 | 3053196 | 103382 | None | 019 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 10442.25 | 10442.25 | 0.594 | False | None | None | False | None | False | 6202.6965 | 0 | 3053197 | 103382 | None | 020 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per pecification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.
| Sqm | 857.85 | 857.85 | 127.7728 | False | None | None | False | None | False | 109609.89648 | 0 | 3053198 | 103382 | None | 021 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.
| Cum | 144977.7 | 144977.7 | 0.3915 | False | None | None | False | None | False | 56758.76955 | 0 | 3053199 | 103382 | None | 022 | Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures )
| Sqm | 7816.2 | 7816.2 | 10.71 | False | None | None | False | None | False | 83711.502 | 0 | 3053200 | 103382 | None | 023 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.
| Kg | 192.15 | 192.15 | 215.46 | False | None | None | False | None | False | 41400.639 | 0 | 3053201 | 103382 | None | 024 | Providing & fixing of 3 track 2-panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2 Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile hrough-out the window frame The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm nd mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T & P's shall not be made) | Sqm | 7070.7 | 7070.7 | 10.26 | False | None | None | False | None | False | 72545.382 | 0 | 3053202 | 103382 | None | 025 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement ortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever equired smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 389.55 | 389.55 | 129.6 | False | None | None | False | None | False | 50485.68 | 0 | 3053203 | 103382 | None | 026 | Supplying, Fitting and Placing TMT Fe 500 & above Reinforcement in Foundation / Substructure Superstructure complete as per Drawing and Technical Specifications.
| Tonne | 93929.85 | 93929.85 | 5.353 | False | None | None | False | None | False | 502806.48705 | 0 | 3053204 | 103382 | None | 027 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the ngineerin- Charge.)
| Kg | 192.15 | 192.15 | 90.72 | False | None | None | False | None | False | 17431.848 | 0 |
| 1710343760000 | 0 | None | None | Buildings | 3 Construction of Storm Water Drain from Prakash Chavhan House to Subbu Nayak Tanda Bridge in Kalagi Town 3.2 Construction of Public Toilet Building at Ramanagar area in Kalagi Town | 3384307.03 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3053205 | 103383 | None | 001 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m
| Cum | 107.1 | 107.1 | 268.32 | False | None | None | False | None | False | 28737.072 | 0 | 3053206 | 103383 | None | 002 | Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work
| Cum | 89.25 | 89.25 | 134.16 | False | None | None | False | None | False | 11973.78 | 0 | 3053207 | 103383 | None | 003 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates
| Cum | 6288.45 | 6288.45 | 22.36 | False | None | None | False | None | False | 140609.742 | 0 | 3053208 | 103383 | None | 004 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) 2.3.2 M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates
| Cum | 7144.2 | 7144.2 | 44.18 | False | None | None | False | None | False | 315630.756 | 0 | 3053209 | 103383 | None | 005 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) 2.4.3 M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates
| Cum | 6971.11 | 6971.11 | 77.0 | False | None | None | False | None | False | 536775.47 | 0 | 3053210 | 103383 | None | 006 | Supplying, Fitting and Placing TMT Fe 550 & above Reinforcement in Foundation / Substructure / Superstructure complete as per Drawing and Technical Specifications.
| Tonne | 82961.55 | 82961.55 | 8.9309 | False | None | None | False | None | False | 740921.306895 | 0 | 3053211 | 103383 | None | 007 | Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, trutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.
| Cum | 95.55 | 95.55 | 30.96 | False | None | None | False | None | False | 2958.228 | 0 | 3053212 | 103383 | None | 008 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.Depth exceeding 1.5m, but not exceeding 3 m
| Cum | 508.2 | 508.2 | 86.01 | False | None | None | False | None | False | 43710.282 | 0 | 3053213 | 103383 | None | 009 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates
| Cum | 6288.45 | 6288.45 | 5.039 | False | None | None | False | None | False | 31687.49955 | 0 | 3053214 | 103383 | None | 010 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 7170.28 | 7170.28 | 3.042 | False | None | None | False | None | False | 21811.99176 | 0 | 3053215 | 103383 | None | 011 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) 2.3.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 7348.32 | 7348.32 | 1.8216 | False | None | None | False | None | False | 13385.699712 | 0 | 3053216 | 103383 | None | 012 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) 2.3.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 10206.0 | 10206.0 | 2.262 | False | None | None | False | None | False | 23085.972 | 0 | 3053217 | 103383 | None | 013 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)
| Cum | 6708.45 | 6708.45 | 13.572 | False | None | None | False | None | False | 91047.0834 | 0 | 3053218 | 103383 | None | 014 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge.
| Sqm | 267.75 | 267.75 | 22.62 | False | None | None | False | None | False | 6056.505 | 0 | 3053219 | 103383 | None | 015 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
| Cum | 279.3 | 279.3 | 81.954 | False | None | None | False | None | False | 22889.7522 | 0 | 3053220 | 103383 | None | 016 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS
2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications."
| Sqm | 1375.5 | 1375.5 | 109.02 | False | None | None | False | None | False | 149957.01 | 0 | 3053221 | 103383 | None | 017 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates
| Cum | 6288.45 | 6288.45 | 0.054 | False | None | None | False | None | False | 339.5763 | 0 | 3053222 | 103383 | None | 018 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super lasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 11138.4 | 11138.4 | 0.216 | False | None | None | False | None | False | 2405.8944 | 0 | 3053223 | 103383 | None | 019 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super lasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, uring and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm ominal size graded crushed coarse aggregates
| Cum | 11138.4 | 11138.4 | 2.262 | False | None | None | False | None | False | 25195.0608 | 0 | 3053224 | 103383 | None | 020 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super lasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 10442.25 | 10442.25 | 6.9325 | False | None | None | False | None | False | 72390.898125 | 0 | 3053225 | 103383 | None | 021 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates
| Cum | 6288.45 | 6288.45 | 0.864 | False | None | None | False | None | False | 5433.2208 | 0 | 3053226 | 103383 | None | 022 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per pecifications and as per directions of the Engineer-in-Charge.
| Sqm | 8689.8 | 8689.8 | 3.15 | False | None | None | False | None | False | 27372.87 | 0 | 3053227 | 103383 | None | 023 | Providing and fixing factory made UPVC Door Frame made of UPVC extruded sections having an overall dimension as below (tolerance +/- 1mm ) with wall thickness 2.00mm (+/- 2mm), corners of the door frames to be jointed with galvanised brackets and stainless steel screws,joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanised MS Tube of size 19mm X 19mm and 1mm (+/-1mm) wall thickness and 3 Nos stainless steel hinges fixed to the frame complete as per manufacturer specification and direction of Engineer-in-charge.
| Rmtr | 250.95 | 250.95 | 41.4 | False | None | None | False | None | False | 10389.33 | 0 | 3053228 | 103383 | None | 024 | Providing and fixing of openable Door made out of multi chambered UPVC (matching to RAL-9016) sections and with minimum Ti02 (Titanium Doxide) at 6PHR with TPV (Thermo Plastic Vulcanised) and lead free with gasket -grey color having isolated drainage and reinforced with Galvanised Iron profile through out the openable frame. The frame having overall size of 60mm X 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm X 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm X 34mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & multi point locking system with handle. Wall thickness of frame and sash shall be of 2mm-2.50mm. Maximum possible size - 900mm X 2400mm. (The cost is inclusive of all fixtures and separate charge for minor T&P's shall not be made)
| Sqm | 6557.25 | 6557.25 | 16.38 | False | None | None | False | None | False | 107407.755 | 0 | 3053229 | 103383 | None | 025 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.
| Kg | 192.15 | 192.15 | 34.02 | False | None | None | False | None | False | 6536.943 | 0 | 3053230 | 103383 | None | 026 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement ortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever equired smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 389.55 | 389.55 | 110.31 | False | None | None | False | None | False | 42971.2605 | 0 | 3053231 | 103383 | None | 027 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, uring complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 253.05 | 253.05 | 142.02 | False | None | None | False | None | False | 35938.161 | 0 | 3053232 | 103383 | None | 028 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 253.05 | 253.05 | 1.44 | False | None | None | False | None | False | 364.392 | 0 | 3053233 | 103383 | None | 029 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm
| Sqm | 1233.75 | 1233.75 | 45.0568 | False | None | None | False | None | False | 55588.827 | 0 | 3053234 | 103383 | None | 030 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement ortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete.
| Sqm | 1161.3 | 1161.3 | 75.74 | False | None | None | False | None | False | 87956.862 | 0 | 3053235 | 103383 | None | 031 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per pecifications and as per directions of Engineer in charge.
| Sqm | 105.0 | 105.0 | 142.02 | False | None | None | False | None | False | 14912.1 | 0 | 3053236 | 103383 | None | 032 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per pecifications and as per directions of Engineer-in-charge.
| Sqm | 133.35 | 133.35 | 142.02 | False | None | None | False | None | False | 18938.367 | 0 | 3053237 | 103383 | None | 033 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to move all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 186.9 | 186.9 | 110.31 | False | None | None | False | None | False | 20616.939 | 0 | 3053238 | 103383 | None | 034 | Supplying, Fitting and Placing TMT Fe 500 & above Reinforcement in Foundation / Substructure Superstructure complete as per Drawing and Technical Specifications.
| Tonne | 93929.85 | 93929.85 | 1.8215 | False | None | None | False | None | False | 171093.221775 | 0 | 3053239 | 103383 | None | 035 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the ngineerin- Charge.)
| Kg | 192.15 | 192.15 | 100.8 | False | None | None | False | None | False | 19368.72 | 0 | 3053240 | 103383 | None | 036 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge
| Sqm | 333.9 | 333.9 | 16.38 | False | None | None | False | None | False | 5469.282 | 0 | 3053241 | 103383 | None | 037 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per Manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.12.55.2 -do- with one side prelam
| Cum | 2142.0 | 2142.0 | 16.38 | False | None | None | False | None | False | 35085.96 | 0 | 3053242 | 103383 | None | 038 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter
| Mtr | 305.55 | 305.55 | 25.0 | False | None | None | False | None | False | 7638.75 | 0 | 3053243 | 103383 | None | 039 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, if c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipes
| Mtr | 397.95 | 397.95 | 20.0 | False | None | None | False | None | False | 7959.0 | 0 | 3053244 | 103383 | None | 040 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, if c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipes
| Mtr | 584.85 | 584.85 | 20.0 | False | None | None | False | None | False | 11697.0 | 0 | 3053245 | 103383 | None | 041 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required 14.2.1 W.C. pan with ISI marked white solid plastic seat and lid
| Each | 5076.75 | 5076.75 | 6.0 | False | None | None | False | None | False | 30460.5 | 0 | 3053246 | 103383 | None | 042 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 14.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
| Each | 320.25 | 320.25 | 8.0 | False | None | None | False | None | False | 2562.0 | 0 | 3053247 | 103383 | None | 043 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 13.5.3 25 mm nominal bore
| Each | 348.6 | 348.6 | 4.0 | False | None | None | False | None | False | 1394.4 | 0 | 3053248 | 103383 | None | 044 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base suooort for tank.
| Ltr | 9.45 | 9.45 | 2000.0 | False | None | None | False | None | False | 18900.0 | 0 | 3053249 | 103383 | None | 045 | Providing and fixing unplasticised PVC connection pipe with brass unions : 45 cm length
13.8.2.1 15 mm nominal bore"
| Nos | 95.55 | 95.55 | 4.0 | False | None | None | False | None | False | 382.2 | 0 | 3053250 | 103383 | None | 046 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
| Nos | 1281.0 | 1281.0 | 2.0 | False | None | None | False | None | False | 2562.0 | 0 | 3053251 | 103383 | None | 047 | Providing and fixing 100 mm sand cast Iron grating for gully trap.
| Each | 49.35 | 49.35 | 2.0 | False | None | None | False | None | False | 98.7 | 0 | 3053252 | 103383 | None | 048 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth Page No.6 Item No. 1.5.1 KPWD. Volumn -1 DSR 2023-24
| Cum | 313.95 | 313.95 | 72.81 | False | None | None | False | None | False | 22858.6995 | 0 | 3053253 | 103383 | None | 049 | Providing Brick work with common burnt clay machine moulded perforated bricks of class designation 3.5 in superstructure above plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) With Non modular bricks including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
| Cum | 8367.45 | 8367.45 | 0.828 | False | None | None | False | None | False | 6928.2486 | 0 | 3053254 | 103383 | None | 050 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 404.25 | 404.25 | 12.64 | False | None | None | False | None | False | 5109.72 | 0 | 3053255 | 103383 | None | 051 | Providing and laying 100mm thick pre-cast cover slabs over drains & Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. itm.no 17.12 Page No.152 KPWD. Volumn -2 DSR 2023-24
| Sqm | 974.4 | 974.4 | 1.3778 | False | None | None | False | None | False | 1342.52832 | 0 | 3053256 | 103383 | None | 052 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe32 mm dia ( item no 14.28.2.1 ) page no 123 PWP. DSR 2023-24
| Each | 96.6 | 96.6 | 3.0 | False | None | None | False | None | False | 289.8 | 0 | 3053257 | 103383 | None | 053 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
| Each | 4676.7 | 4676.7 | 2.0 | False | None | None | False | None | False | 9353.4 | 0 | 3053258 | 103383 | None | 054 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. SEMI RIGID pipe32 mm dia ( item no 14.28.1.1 ) page no 123 PWP. DSR 2023-24
| Each | 79.8 | 79.8 | 2.0 | False | None | None | False | None | False | 159.6 | 0 | 3053259 | 103383 | None | 055 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 14.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
| Each | 3236.1 | 3236.1 | 3.0 | False | None | None | False | None | False | 9708.3 | 0 | 3053260 | 103383 | None | 056 | Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19/20mm dia 2mm thick.
| Mtr | 69.0 | 69.0 | 20.0 | False | None | None | False | None | False | 1380.0 | 0 | 3053261 | 103383 | None | 057 | Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25mm dia 2mm thick.
| Mtr | 81.0 | 81.0 | 20.0 | False | None | None | False | None | False | 1620.0 | 0 | 3053262 | 103383 | None | 058 | Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 32mm dia 2.5mm thick.
| Mtr | 106.0 | 106.0 | 20.0 | False | None | None | False | None | False | 2120.0 | 0 | 3053263 | 103383 | None | 059 | Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19/20mm dia 2mm thick
| Mtr | 68.0 | 68.0 | 20.0 | False | None | None | False | None | False | 1360.0 | 0 | 3053264 | 103383 | None | 060 | Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25mm dia 2mm thick
| Mtr | 79.0 | 79.0 | 20.0 | False | None | None | False | None | False | 1580.0 | 0 | 3053265 | 103383 | None | 062 | Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary 32mm dia 2.5mm thick
| Mtr | 99.0 | 99.0 | 50.0 | False | None | None | False | None | False | 4950.0 | 0 | 3053266 | 103383 | None | 063 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, screws at an interval of 300mm …. etc. as required.25mm
| Mtr | 35.0 | 35.0 | 100.0 | False | None | None | False | None | False | 3500.0 | 0 | 3053267 | 103383 | None | 064 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A 2.2.1 Short point upto 3m from tapping point to out let via switch box
| Point | 251.0 | 251.0 | 1.0 | False | None | None | False | None | False | 251.0 | 0 | 3053268 | 103383 | None | 065 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A
2.2.2 Medium point above 3m upto 6m from tapping point to out let via switch box"
| Point | 361.0 | 361.0 | 1.0 | False | None | None | False | None | False | 361.0 | 0 | 3053269 | 103383 | None | 066 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A Long point above 6m upto 10m from tapping point to out let via switch box
| Point | 542.0 | 542.0 | 1.0 | False | None | None | False | None | False | 542.0 | 0 | 3053270 | 103383 | None | 067 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A
Two outlet in a row, above 3m upto 6m from tapping point to out let via switches "
| Point | 671.0 | 671.0 | 5.0 | False | None | None | False | None | False | 3355.0 | 0 | 3053271 | 103383 | None | 068 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A
Three outlet in a row, above 6m upto 10m from tapping point to out let via switches box"
| Point | 979.0 | 979.0 | 1.0 | False | None | None | False | None | False | 979.0 | 0 | 3053272 | 103383 | None | 069 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
2.3.2 1.5 mm2 "
| Mtr | 26.0 | 26.0 | 50.0 | False | None | None | False | None | False | 1300.0 | 0 | 3053273 | 103383 | None | 070 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.3.3 2.5 mm2
| Mtr | 40.0 | 40.0 | 50.0 | False | None | None | False | None | False | 2000.0 | 0 | 3053274 | 103383 | None | 071 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.3.4 4 mm2
| Mtr | 59.0 | 59.0 | 50.0 | False | None | None | False | None | False | 2950.0 | 0 | 3053275 | 103383 | None | 072 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.3.5 6 mm2
| Mtr | 87.0 | 87.0 | 50.0 | False | None | None | False | None | False | 4350.0 | 0 | 3053276 | 103383 | None | 074 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 2.3.6 10 mm2
| Mtr | 157.0 | 157.0 | 25.0 | False | None | None | False | None | False | 3925.0 | 0 | 3053277 | 103383 | None | 075 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.1 1-3 Way
| Each | 123.0 | 123.0 | 2.0 | False | None | None | False | None | False | 246.0 | 0 | 3053278 | 103383 | None | 076 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.3 6 Way
| Each | 212.0 | 212.0 | 1.0 | False | None | None | False | None | False | 212.0 | 0 | 3053279 | 103383 | None | 077 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3.5.1 1 to 3 Module
| Each | 152.0 | 152.0 | 2.0 | False | None | None | False | None | False | 304.0 | 0 | 3053280 | 103383 | None | 078 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3.5.3 6 Module
| Each | 244.0 | 244.0 | 1.0 | False | None | None | False | None | False | 244.0 | 0 | 3053281 | 103383 | None | 079 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.1 6A One Way Switch
| Each | 88.0 | 88.0 | 5.0 | False | None | None | False | None | False | 440.0 | 0 | 3053282 | 103383 | None | 080 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.3 6A Three Way socket
| Each | 162.0 | 162.0 | 2.0 | False | None | None | False | None | False | 324.0 | 0 | 3053283 | 103383 | None | 081 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.8 16A One Way Switch
| Each | 261.45 | 261.45 | 2.0 | False | None | None | False | None | False | 522.9 | 0 | 3053284 | 103383 | None | 082 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.11 6/16A Universal Socket
| Each | 249.0 | 249.0 | 5.0 | False | None | None | False | None | False | 1245.0 | 0 | 3053285 | 103383 | None | 083 | LED Indoor Supplying of .feet -PVC Batten with integrated LED tube . W with high
uality diffuser with Life of 25000 burning hours & 70 lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. 11.3.3 LED light fitting 1 x 4 - 36/40 W | Each | 1197.0 | 1197.0 | 2.0 | False | None | None | False | None | False | 2394.0 | 0 | 3053286 | 103383 | None | 084 | Supply of round square recess surface mounted rolling type LED Down light with W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector has swivelling unit of aluminium die cast eye ball LED Lamp position retained by circular wire spring, with Life of 25000 burning hours 70 lumen maintenance with CRI 80 Power Input: 220 240V 50 60Hz Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition 11.5.3 LED square or round down light 15 18 | Each | 1249.0 | 1249.0 | 2.0 | False | None | None | False | None | False | 2498.0 | 0 | 3053287 | 103383 | None | 085 | LED Down light Supplying of recess mounting non integrated type LED down light. W luminaire comprising of pressure decast extruded aluminium housing, with spring loaded false ceiling clA, | Each | 2174.0 | 2174.0 | 2.0 | False | None | None | False | None | False | 4348.0 | 0 | 3053288 | 103383 | None | 086 | Supplying and fixing of round or oblong type bulk head fitting glass cover
| Each | 68.0 | 68.0 | 3.0 | False | None | None | False | None | False | 204.0 | 0 | 3053289 | 103383 | None | 087 | Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 6.2.2 15" Sweep (450 mm)
| Each | 4126.0 | 4126.0 | 4.0 | False | None | None | False | None | False | 16504.0 | 0 | 3053290 | 103383 | None | 088 | Fixing all types and all capacities fluorescent/false ceiling/spot light/ CFL fittings indoor on the wall/ ceiling/rafters/girders using 23/0.0076'' twin PVC insulated wires, required nos of round blocks and clamps (if required) 13.7.1 On wall/ ceiling / Rafter / Girders
| Each | 119.0 | 119.0 | 5.0 | False | None | None | False | None | False | 595.0 | 0 | 3053291 | 103383 | None | 089 | Fixing a ceiling/wall mounting fan of all capacities and all types with necessary clamps and S hook made out of 15mm dia MS rod, with 5 amps ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality mounted on a suitable size wooden board and wired complete.
| Each | 281.0 | 281.0 | 5.0 | False | None | None | False | None | False | 1405.0 | 0 | 3053292 | 103383 | None | 090 | Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.
| Each | 702.0 | 702.0 | 5.0 | False | None | None | False | None | False | 3510.0 | 0 | 3053293 | 103383 | None | 091 | Fabricating supplying and mounting MS box made out 14 SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with
hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., Complete. 5.42.1 14 SWG"
| Sqm | 0.43 | 0.43 | 37500.0 | False | None | None | False | None | False | 16125.0 | 0 | 3053294 | 103383 | None | 092 | Supplying . amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 5.40.1 100 A 4 x 30 x 6 mm Aluminium Strips
| Mtr | 2214.0 | 2214.0 | 2.0 | False | None | None | False | None | False | 4428.0 | 0 | 3053295 | 103383 | None | 093 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 5.41.1 40 x 40 x 6 mm
| Mtr | 275.0 | 275.0 | 5.0 | False | None | None | False | None | False | 1375.0 | 0 | 3053296 | 103383 | None | 094 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 5.41.4 50 x 100 x 50 x 6 mm C channel
| Mtr | 680.0 | 680.0 | 5.0 | False | None | None | False | None | False | 3400.0 | 0 | 3053297 | 103383 | None | 095 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. THREE Pole 5.14.1 100 A 25 kA
| Each | 5641.0 | 5641.0 | 1.0 | False | None | None | False | None | False | 5641.0 | 0 | 3053298 | 103383 | None | 096 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR Pole 5.14.7 100 A 25 kA
| Each | 8265.0 | 8265.0 | 1.0 | False | None | None | False | None | False | 8265.0 | 0 | 3053299 | 103383 | None | 097 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 40/450V upto 300mA sensitivity on existing wood/panel board. 5.20.3 32-40 A 4 pole
| Each | 2826.0 | 2826.0 | 1.0 | False | None | None | False | None | False | 2826.0 | 0 | 3053300 | 103383 | None | 098 | Supplying and fixing of Shunt trip suitable for MCCB.CBCT.
| Each | 1512.0 | 1512.0 | 1.0 | False | None | None | False | None | False | 1512.0 | 0 | 3053301 | 103383 | None | 099 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.
| Each | 8316.0 | 8316.0 | 1.0 | False | None | None | False | None | False | 8316.0 | 0 | 3053302 | 103383 | None | 100 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.
| Each | 464.0 | 464.0 | 1.0 | False | None | None | False | None | False | 464.0 | 0 | 3053303 | 103383 | None | 101 | Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound.
| Each | 505.0 | 505.0 | 1.0 | False | None | None | False | None | False | 505.0 | 0 | 3053304 | 103383 | None | 100 | Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. etc. complete
(KPWD SR VOL V for the year 2023-24. I. No. 12.4 P.No. 140 )"
| Each | 5552.4 | 5552.4 | 1.0 | False | None | None | False | None | False | 5552.4 | 0 | 3053305 | 103383 | None | 101 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 0 to 50 Mtrs
(KPWD SR VOL V for the year 2023-24. I. No. 12.1.1 P.No. 132 )"
| Rmtr | 388.5 | 388.5 | 50.0 | False | None | None | False | None | False | 19425.0 | 0 | 3053306 | 103383 | None | 102 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 50 to 100 Mtrs
(KPWD SR VOL V for the year 2023-24. I. No. 12.1.2 P.No. 132 )"
| Rmtr | 487.2 | 487.2 | 50.0 | False | None | None | False | None | False | 24360.0 | 0 | 3053307 | 103383 | None | 103 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 100 to 150 Mtrs
(KPWD SR VOL V for the year 2023-24. I. No. 12.1.3 P.No. 132 )"
| Rmtr | 517.65 | 517.65 | 10.0 | False | None | None | False | None | False | 5176.5 | 0 | 3053308 | 103383 | None | 104 | PVC pipes of 6 Kg/cm2 for 160mm
(KPWD SR VOL V for the year 2023-24. Sl No. 649 P.No. A44 )"
| Rmtr | 441.0 | 441.0 | 6.0 | False | None | None | False | None | False | 2646.0 | 0 | 3053309 | 103383 | None | 105 | PVC pipes of 6 Kg/cm2 for 110mm
(KPWD SR VOL V for the year 2023-24. Sl No. 647 P.No. A44 )"
| Rmtr | 267.75 | 267.75 | 110.0 | False | None | None | False | None | False | 29452.5 | 0 | 3053310 | 103383 | None | 106 | Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all Amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in Charge ( (PWD UGD and water supply SR 2023-24 Volume - V Item no.12.34 page no.143)
| Each | 172.2 | 172.2 | 1.0 | False | None | None | False | None | False | 172.2 | 0 | 3053311 | 103383 | None | 107 | Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest ammendments 1.50 HP/1.1KW 20 STG (PWD UGD and water supply SR 2023-24 Volume - V Item no.13.7.7 page no.150)
| Each | 19128.9 | 19128.9 | 1.0 | False | None | None | False | None | False | 19128.9 | 0 | 3053312 | 103383 | None | 108 | Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. (PWD UGD and water supply SR 2023-24 Volume - V Item no.13.31 page no.155)
| Rmtr | 42.0 | 42.0 | 110.0 | False | None | None | False | None | False | 4620.0 | 0 | 3053313 | 103383 | None | 109 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. (PWD UGD and water supply SR 2023-24 Volume - V Item no.13.32 page no.156)
| Job | 6825.0 | 6825.0 | 1.0 | False | None | None | False | None | False | 6825.0 | 0 | 3053314 | 103383 | None | 110 | Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x6 Sqm. (PWD UGD and water supply SR 2023-24 Volume - V Item no.13.22.4 page no.154)
| Rmtr | 194.25 | 194.25 | 115.0 | False | None | None | False | None | False | 22338.75 | 0 | 3053315 | 103383 | None | 111 | Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0 (PWD UGD and water supply SR 2023-24 Volume - V Item no.9.1.1 page no.95)
| Rmtr | 198.45 | 198.45 | 105.0 | False | None | None | False | None | False | 20837.25 | 0 | 3053316 | 103383 | None | 112 | Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments (PWD UGD and water supply SR 2023-24 Volume - V Item no.13.25.2 page no.154)
| Each | 1627.5 | 1627.5 | 1.0 | False | None | None | False | None | False | 1627.5 | 0 | 3053317 | 103383 | None | 113 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter
2) S-D- Star Delta Starter etc. complete.Upto 3 HP pumps (PWD UGD and water supply SR 2023-24 Volume - V Item no.13.24.1 page no.155)"
| Each | 7875.0 | 7875.0 | 1.0 | False | None | None | False | None | False | 7875.0 | 0 | 3053318 | 103383 | None | 114 | Labour charges for erection of outdoor type panel board and meter board units with all necessary materials and labour, tools and equipments including providing cement concrete foundation bed etc., complete as per specification, with testing of as per instructions of engineer incharge of work. (PWD UGD and water supply SR 2023-24 Volume - V Item no.13.34 page no.156)
| Job | 1522.5 | 1522.5 | 1.0 | False | None | None | False | None | False | 1522.5 | 0 | 3053319 | 103383 | None | 115 | Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPTCL authorities and erection, electrification and commissioning of the same at the location of respective pump sets. (PWD UGD and water supply SR 2023-24 Volume - V Item no.13.25 page no.155)
| Kvar | 577.5 | 577.5 | 1.0 | False | None | None | False | None | False | 577.5 | 0 | 3053320 | 103383 | None | 116 | Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box. (PWD UGD and water supply SR 2023-24 Volume - V Item no.13.26 page no.155)
| Per 3 Poles | 1207.5 | 1207.5 | 1.0 | False | None | None | False | None | False | 1207.5 | 0 | 3053321 | 103383 | None | 117 | Labour charges for providing connection using insulated sheathed steel wire cable as per IS 1554/ 1988 with latest amendments from KPTCL pole to meter board unit, with all necessary materials ,tools and equipments,as per specificationswith testing of as per instructions of engineer incharge of work. PWD UGD and water supply SR 2023-24 Volume V Item no.13.35.2 page no.156 | Per 3 Poles | 168.0 | 168.0 | 1.0 | False | None | None | False | None | False | 168.0 | 0 |
|
|
---|