noticeInvitingTenderDTO
createdTs1710498726096
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee7500.00
emd4040000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose15-04-2024 16:00:00
tenderQueryClose03-04-2024 11:00:00
technicalBidOpen16-04-2024 16:30:00
publishedDate16-03-2024 10:47:29
publishedByPostBBMP_EE_CHA_WEST
publishedByUserKPE16006 - G BHASKAR REDDY
bidValidityPeriod180
noOfCalls1
preBidMeetingDate03-04-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonG BHASKAR REDDY
splitEmdRequiredYnTrue
emdBankGuarantee3940000.00
emdCash100000.00
bgValidityPeriod365
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9480688278
tenderSupplierListNone
tenderSchedule
createdTs1710498726126
version4
createdDateNone
modifiedDateNone
tenderNumberBBMP/2023-24/BD/WORK_INDENT3091
titlePackage-1 Construction of Various BBMP Offices, Hospitals Dialysis Center, Samudhaya Bhavan Building & Gym Building in Chamrajpet Assembly CALL-2
descriptionPackage-1 Construction of Various BBMP Offices, Hospitals Dialysis Center, Samudhaya Bhavan Building & Gym Building in Chamrajpet Assembly
categoryWORKS
categoryTextWorks
ecv395915014.68
deptNameBruhat Bengaluru Mahanagara Palike
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location873
locationNameBBMP Chamarajpete West
provisionalAmount404000000.0
groupOverheadTotalNone
fileNumberEE/CRP/PR/2023-24/90
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17104987260000NoneNoneBuildingsPackage-1 Construction of Various BBMP Offices, Hospitals Dialysis Center, Samudhaya Bhavan Building & Gym Building in Chamrajpet Assembly395915014.68
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3089401106226Nonecode01Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 m3 in volume and stock piling at designated locations and disposal of dismantled materials and stacking serviceable and unserviceable materials separately.Complete specification as per engineer in charge.Cum730.78730.7843.401FalseNoneNoneFalseNoneFalse31716.582780
3089402106226Nonecode02Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. In cement mortar.Complete specification as per engineer in charge.Cum1335.651335.651387.02FalseNoneNoneFalseNoneFalse1852573.2630
3089403106226Nonecode03Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. In cement mortar Complete specification as per engineer in charge.Cum1349.01349.022.05FalseNoneNoneFalseNoneFalse29745.450
3089404106226Nonecode04Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. Ground Floor Complete specification as per engineer in charge.Cum3148.953148.95976.631FalseNoneNoneFalseNoneFalse3075362.187450
3089405106226Nonecode05Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. Frist Floor Complete specification as per engineer in charge.Cum3180.453180.4532.055FalseNoneNoneFalseNoneFalse101949.324750
3089406106226Nonecode06Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer in-charge In cement mortar Complete specification as per engineer in charge.Cum2185.842185.8424.0FalseNoneNoneFalseNoneFalse52460.160
3089407106226Nonecode07Dismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually/ by mechanical means including stacking of serviceable and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.m3 1,001.00 19.10.2 In cement mortar Complete specification as per engineer in charge.Cum1299.31299.390.997FalseNoneNoneFalseNoneFalse118232.40210
3089408106226Nonecode08Earth work in surface excavation by mechanical means for lowering & leveling the ground without blasting for all works other than foundation in Ordinary/Soft rock & depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work Complete specification as per engineer in charge.Cum469.88469.881552.994FalseNoneNoneFalseNoneFalse729720.820720
3089409106226Nonecode09Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m Complete specification as per engineer in charge.Cum314.12314.12315.087FalseNoneNoneFalseNoneFalse98975.128440
3089410106226Nonecode10Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth Complete specification as per engineer in charge.Cum471.18471.18549.74FalseNoneNoneFalseNoneFalse259026.49320
3089411106226Nonecode11Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.Depth exceeding 1.5 m, but not exceeding 3 m Complete specification as per engineer in charge.Cum551.65551.653417.193FalseNoneNoneFalseNoneFalse1885094.518450
3089412106226Nonecode12Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. Complete specification as per engineer in charge.Sqm153.17153.172341.8FalseNoneNoneFalseNoneFalse358693.5060
3089413106226Nonecode13Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Complete specification as per engineer in charge.Cum345.27345.271535.44FalseNoneNoneFalseNoneFalse530141.36880
3089414106226Nonecode14Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates.Complete specification as per engineer in charge.Cum7773.737773.73357.52FalseNoneNoneFalseNoneFalse2779263.94960
3089415106226Nonecode15Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates.Complete specification as per engineer in charge.Cum8069.678069.6799.137FalseNoneNoneFalseNoneFalse800002.874790
3089416106226Nonecode16Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) Complete specification as per engineer in charge.Cum8292.938292.93645.52FalseNoneNoneFalseNoneFalse5353252.17360
3089417106226Nonecode17Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lin ing, including cost of materials, labour, curing as per ecifications and as per directions of Engineer-inSqm330.99330.991145.044FalseNoneNoneFalseNoneFalse378998.113560
3089418106226Nonecode18Providing and laying in position Reinforcement Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Complete specification as per engineer in charge.Cum8882.078882.07996.418FalseNoneNoneFalseNoneFalse8850254.425260
3089419106226Nonecode19Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates. Complete specification as per engineer in charge.Cum8069.678069.677.74FalseNoneNoneFalseNoneFalse62459.24580
3089420106226Nonecode20Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates Complete specification as per engineer in charge.Cum8728.028728.02101.17FalseNoneNoneFalseNoneFalse883013.78340
3089421106226Nonecode21Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Ground Floor Complete specification as per engineer in charge.Sqm1597.841597.841322.455FalseNoneNoneFalseNoneFalse2113071.49720
3089422106226Nonecode22Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Frist Floor Complete specification as per engineer in charge.Sqm1613.831613.83928.29FalseNoneNoneFalseNoneFalse1498102.25070
3089423106226Nonecode23Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Second Floor Complete specification as per engineer in charge.Sqm1629.811629.81265.41FalseNoneNoneFalseNoneFalse432567.87210
3089424106226Nonecode24Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Columns Complete specification as per engineer in charge.Cum13872.913872.921.84FalseNoneNoneFalseNoneFalse302984.1360
3089425106226Nonecode25Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ) For Footing Complete specification as per engineer in charge.Cum8813.388813.38227.821FalseNoneNoneFalseNoneFalse2007873.044980
3089426106226Nonecode26Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Columns Complete specification as per engineer in charge.Cum13981.0213981.0251.21FalseNoneNoneFalseNoneFalse715968.03420
3089427106226Nonecode27Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Plinth Beam Complete specification as per engineer in charge.Cum12336.212336.2294.12FalseNoneNoneFalseNoneFalse3628323.1440
3089428106226Nonecode28Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Sump Complete specification as per engineer in charge.Cum8882.078882.0710.32FalseNoneNoneFalseNoneFalse91662.96240
3089429106226Nonecode29Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Ground Floor For Slab lintel Plinth beam Complete specification as per engineer in charge.Cum13323.3313323.33125.21FalseNoneNoneFalseNoneFalse1668214.14930
3089430106226Nonecode30Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Ground Floor For Column Complete specification as per engineer in charge.Cum15099.7715099.77121.236FalseNoneNoneFalseNoneFalse1830635.715720
3089431106226Nonecode31Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Ground Floor For Stair case & Slab Complete specification as per engineer in charge.Cum13323.3313323.33452.691FalseNoneNoneFalseNoneFalse6031351.581030
3089432106226Nonecode32Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Ground Floor Beam & Lintel Complete specification as per engineer in charge.Cum14211.5514211.55367.78FalseNoneNoneFalseNoneFalse5226723.8590
3089433106226Nonecode33Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesFirst Floor Slab Complete specification as per engineer in charge.Cum13456.5613456.56109.716FalseNoneNoneFalseNoneFalse1476399.936960
3089434106226Nonecode34Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates First Floor For Column Complete specification as per engineer in charge.Cum15250.7715250.77101.159FalseNoneNoneFalseNoneFalse1542752.642430
3089435106226Nonecode35Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates First Floor For Stair case & Slab Complete specification as per engineer in charge.Cum13456.5613456.56341.57FalseNoneNoneFalseNoneFalse4596357.19920
3089436106226Nonecode36Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates First Floor Beam & Lintel Complete specification as per engineer in charge.Cum14353.6714353.67214.948FalseNoneNoneFalseNoneFalse3085292.659160
3089437106226Nonecode37Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Second Floor Lintel Slab Complete specification as per engineer in charge.Cum13589.7913589.7914.52FalseNoneNoneFalseNoneFalse197323.75080
3089438106226Nonecode38Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Second Floor For Column Complete specification as per engineer in charge.Cum15401.7715401.7749.176FalseNoneNoneFalseNoneFalse757397.441520
3089439106226Nonecode39Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Second Floor For Stair case Complete specification as per engineer in charge.Cum13589.7913589.79253.782FalseNoneNoneFalseNoneFalse3448844.085780
3089440106226Nonecode40Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Second Floor Beam Complete specification as per engineer in charge.Cum14495.7914495.79155.477FalseNoneNoneFalseNoneFalse2253761.941830
3089441106226Nonecode41Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ) Ground Floor-Floor Concrete Complete specification as per engineer in charge.Cum8605.748605.74192.78FalseNoneNoneFalseNoneFalse1659014.55720
3089442106226Nonecode42Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Ground Floor-Chejja Complete specification as per engineer in charge.Cum12478.3312478.3368.426FalseNoneNoneFalseNoneFalse853842.208580
3089443106226Nonecode43Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates First Floor-Chejja Complete specification as per engineer in charge.Cum12603.1112603.1116.044FalseNoneNoneFalseNoneFalse202204.296840
3089444106226Nonecode44Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Second Floor-Chejja Complete specification as per engineer in charge.Cum12727.912727.96.684FalseNoneNoneFalseNoneFalse85073.28360
3089445106226Nonecode45Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) Ground Floor Complete specification as per engineer in charge.Tonne116115.18116115.18365.101FalseNoneNoneFalseNoneFalse42393768.333180
3089446106226Nonecode46Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) Frist Floor Complete specification as per engineer in charge.Tonne117276.34117276.34139.509FalseNoneNoneFalseNoneFalse16361104.917060
3089447106226Nonecode47Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) Second Floor Complete specification as per engineer in charge.Tonne118437.5118437.579.812FalseNoneNoneFalseNoneFalse9452733.750
3089448106226Nonecode48Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ground Floor Complete specification as per engineer in charge.Sqm330.99330.993702.122FalseNoneNoneFalseNoneFalse1225365.360780
3089449106226Nonecode49Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Frist Floor Complete specification as per engineer in charge.Sqm334.31334.312418.71FalseNoneNoneFalseNoneFalse808598.94010
3089450106226Nonecode50Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Second Floor Complete specification as per engineer in charge.Sqm337.61337.61429.095FalseNoneNoneFalseNoneFalse144866.762950
3089451106226Nonecode51Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ground Floor Complete specification as per engineer in charge.Sqm382.91382.911201.805FalseNoneNoneFalseNoneFalse460183.152550
3089452106226Nonecode52Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Frist Floor Complete specification as per engineer in charge.Sqm386.75386.75748.63FalseNoneNoneFalseNoneFalse289532.65250
3089453106226Nonecode53Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ) Second Floor Complete specification as per engineer in charge.Sqm390.57390.57158.52FalseNoneNoneFalseNoneFalse61913.15640
3089454106226Nonecode54Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Ground Floor Complete specification as per engineer in charge.Sqm129.8129.89964.159FalseNoneNoneFalseNoneFalse1293347.83820
3089455106226Nonecode55Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Frist Floor Complete specification as per engineer in charge.Sqm131.1131.17936.045FalseNoneNoneFalseNoneFalse1040415.49950
3089456106226Nonecode56Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Second Floor Complete specification as per engineer in charge.Sqm132.39132.393328.456FalseNoneNoneFalseNoneFalse440654.289840
3089457106226Nonecode57Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Ground Floor Complete specification as per engineer in charge.Sqm164.85164.857427.57FalseNoneNoneFalseNoneFalse1224434.91450
3089458106226Nonecode58Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Frist Floor Complete specification as per engineer in charge.Sqm166.5166.56226.245FalseNoneNoneFalseNoneFalse1036669.79250
3089459106226Nonecode59Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Second Floor Complete specification as per engineer in charge.Sqm168.15168.152208.766FalseNoneNoneFalseNoneFalse371404.00290
3089460106226Nonecode60Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge Ground Floor Complete specification as per engineer in charge.Sqm367.34367.342314.621FalseNoneNoneFalseNoneFalse850252.878140
3089461106226Nonecode61Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Frist Floor Complete specification as per engineer in charge.Sqm371.02371.021802.807FalseNoneNoneFalseNoneFalse668877.453140
3089462106226Nonecode62Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Second Floor Complete specification as per engineer in charge.Sqm374.69374.69624.362FalseNoneNoneFalseNoneFalse233942.197780
3089463106226Nonecode63Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Ground Floor Complete specification as per engineer in charge.Sqm225.85225.853313.021FalseNoneNoneFalseNoneFalse748245.792850
3089464106226Nonecode64Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. First Floor Complete specification as per engineer in charge.Sqm228.12228.12961.17FalseNoneNoneFalseNoneFalse219262.10040
3089465106226Nonecode65Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ) Second Floor Complete specification as per engineer in charge.Sqm230.38230.38961.17FalseNoneNoneFalseNoneFalse221434.34460
3089466106226Nonecode66Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 (1 cement: 3 coarse sand) proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, labour ,mortar,curing etc , Complete specification as per engineer in charge.Sqm4359.994359.99471.13FalseNoneNoneFalseNoneFalse2054122.08870
3089467106226Nonecode67Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, griding the edge to half/full round wherever required, labour, curing complete as per specification.Sqm1209.741209.74564.35FalseNoneNoneFalseNoneFalse682716.7690
3089468106226Nonecode68Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. Ground Floor Complete specification as per engineer in charge.Sqm1396.651396.65298.51FalseNoneNoneFalseNoneFalse416913.99150
3089469106226Nonecode69Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. Frist Floor Complete specification as per engineer in charge.Sqm1410.621410.62594.688FalseNoneNoneFalseNoneFalse838878.786560
3089470106226Nonecode70Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. Second Floor Complete specification as per engineer in charge.Sqm1424.61424.681.176FalseNoneNoneFalseNoneFalse115643.32960
3089471106226Nonecode71Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 500x500 mm Ground Floor Complete specification as per engineer in charge.Sqm1443.371443.37764.04FalseNoneNoneFalseNoneFalse1102792.41480
3089472106226Nonecode72Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 500x500 mm Frist Floor Complete specification as per engineer in charge.Sqm1457.821457.82276.605FalseNoneNoneFalseNoneFalse403240.30110
3089473106226Nonecode73Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 500x500 mm Second Floor Complete specification as per engineer in charge.Sqm1472.261472.2648.69FalseNoneNoneFalseNoneFalse71684.33940
3089474106226Nonecode74Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Ground Floor Complete specification as per engineer in charge.Sqm3200.873200.871337.23FalseNoneNoneFalseNoneFalse4280299.39010
3089475106226Nonecode75Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Frist Floor Complete specification as per engineer in charge.Sqm3232.893232.89648.21FalseNoneNoneFalseNoneFalse2095591.62690
3089476106226Nonecode76Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Second Floor Complete specification as per engineer in charge.Sqm3264.93264.9107.48FalseNoneNoneFalseNoneFalse350911.4520
3089477106226Nonecode77Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. Ground Floor Complete specification as per engineer in charge.Sqm6915.756915.7590.99FalseNoneNoneFalseNoneFalse629264.09250
3089478106226Nonecode78Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. Frist Floor Complete specification as per engineer in charge.Sqm6984.916984.9153.64FalseNoneNoneFalseNoneFalse374670.57240
3089479106226Nonecode79Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. Second Floor Complete specification as per engineer in charge.Sqm7054.077054.0720.7FalseNoneNoneFalseNoneFalse146019.2490
3089480106226Nonecode80Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. Ground Floor Complete specification as per engineer in charge.Sqm1060.471060.47701.7FalseNoneNoneFalseNoneFalse744131.7990
3089481106226Nonecode81Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. First Floor Complete specification as per engineer in charge.Sqm1071.081071.081948.72FalseNoneNoneFalseNoneFalse2087235.01760
3089482106226Nonecode82Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. Second Floor Complete specification as per engineer in charge.Sqm1081.691081.69986.0FalseNoneNoneFalseNoneFalse1066546.340
3089483106226Nonecode83Providing & fixing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame.Flat surfaces Ground Floor Complete specification as per engineer in charge.Sqm1653.661653.66606.0FalseNoneNoneFalseNoneFalse1002117.960
3089484106226Nonecode84Providing & fixing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame.Flat surfaces Frist Floor Complete specification as per engineer in charge.Sqm1670.21670.21020.54FalseNoneNoneFalseNoneFalse1704505.9080
3089485106226Nonecode85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ) Ground Floor Complete specification as per engineer in charge.Sqm7423.277423.2787.18FalseNoneNoneFalseNoneFalse647160.67860
3089486106226Nonecode86Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size -1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Frist Floor Complete specification as per engineer in charge.Sqm7497.57497.520.34FalseNoneNoneFalseNoneFalse152499.150
3089487106226Nonecode87Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Second Floor Complete specification as per engineer in charge.Sqm7571.737571.7312.24FalseNoneNoneFalseNoneFalse92677.97520
3089488106226Nonecode88Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Ground Floor Complete specification as per engineer in charge.Sqm8503.28503.2180.0FalseNoneNoneFalseNoneFalse1530576.00
3089489106226Nonecode89Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Frist Floor Complete specification as per engineer in charge.Sqm8588.258588.2545.0FalseNoneNoneFalseNoneFalse386471.250
3089490106226Nonecode90Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size -1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Second Floor Complete specification as per engineer in charge.Sqm8899.678899.6722.5FalseNoneNoneFalseNoneFalse200242.5750
3089491106226Nonecode91Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having a overall size of 60mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm X 58mm with GI reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2-2.5 mm. Maximum possible size -1819mm x 1819mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made).Ground Floor Complete specification as per engineer in charge.Sqm6996.226996.22209.7FalseNoneNoneFalseNoneFalse1467107.3340
3089492106226Nonecode92Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having a overall size of 60mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm X 58mm with GI reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2-2.5 mm. Maximum possible size - 1819mm x 1819mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made).Frist Floor Complete specification as per engineer in charge.Sqm7066.197066.19182.7FalseNoneNoneFalseNoneFalse1290992.9130
3089493106226Nonecode93Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having a overall size of 60mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm X 58mm with GI reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2-2.5 mm. Maximum possible size - 1819mm x 1819mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made).Second Floor Complete specification as per engineer in charge.Sqm7136.157136.1554.0FalseNoneNoneFalseNoneFalse385352.10
3089494106226Nonecode94Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.. Ground Floor Complete specification as per engineer in charge.Cum128261.87128261.874.275FalseNoneNoneFalseNoneFalse548319.494250
3089495106226Nonecode95Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.. Frist Floor Complete specification as per engineer in charge.Cum129544.5129544.53.96FalseNoneNoneFalseNoneFalse512996.220
3089496106226Nonecode96Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.. Second Floor Complete specification as per engineer in charge.Cum130827.11130827.112.088FalseNoneNoneFalseNoneFalse273167.005680
3089497106226Nonecode97Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. 12.57.1 -do- 30 mm thick Both side teak.) Ground Floor Complete specification as per engineer in charge.Sqm5247.825247.8290.81FalseNoneNoneFalseNoneFalse476554.53420
3089498106226Nonecode98Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. 12.57.1 -do- 30 mm thick Both side teak. Frist Floor Complete specification as per engineer in charge.Sqm5300.315300.3191.17FalseNoneNoneFalseNoneFalse483229.26270
3089499106226Nonecode99Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. 12.57.1 -do- 30 mm thick Both side teak.)Second Floor Complete specification as per engineer in charge.Sqm5352.785352.7844.19FalseNoneNoneFalseNoneFalse236539.34820
3089500106226Nonecode100Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. Ground Floor Complete specification as per engineer in charge.Nos1318.771318.7747.0FalseNoneNoneFalseNoneFalse61982.190
3089501106226Nonecode101Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Frist Floor Complete specification as per engineer in charge.Nos1331.971331.9733.0FalseNoneNoneFalseNoneFalse43955.010
3089502106226Nonecode102Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. Second Floor Complete specification as per engineer in charge.Nos1345.161345.1615.0FalseNoneNoneFalseNoneFalse20177.40
3089503106226Nonecode103Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. Ground Floor Complete specification as per engineer in charge.Mtr412.77412.77257.85FalseNoneNoneFalseNoneFalse106432.74450
3089504106226Nonecode104Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. Frist Floor Complete specification as per engineer in charge.Mtr416.9416.9243.3FalseNoneNoneFalseNoneFalse101431.770
3089505106226Nonecode105Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. Second Floor Complete specification as per engineer in charge.Mtr421.03421.03113.55FalseNoneNoneFalseNoneFalse47807.95650
3089506106226Nonecode106Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges -do- with both side prelam. Ground Floor Complete specification as per engineer in charge.Sqm3071.073071.0797.65FalseNoneNoneFalseNoneFalse299889.98550
3089507106226Nonecode107Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges -do- with both side prelam. Frist Floor Complete specification as per engineer in chargeSqm3101.793101.7912.6FalseNoneNoneFalseNoneFalse39082.5540
3089508106226Nonecode108Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges -do- with both side prelam. Complete specification as per engineer in charge.Sqm3132.53132.53.15FalseNoneNoneFalseNoneFalse9867.3750
3089509106226Nonecode109Providing & fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top & bottom rails, covered with heat moulded PVC C channel of 5mm thick sheet & 30 x 50mm wide to form stiles & 5mm thick & 75mm wide PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the stiles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm Aluminium hinges Ground Floor Complete specification as per engineer in charge.Sqm2061.232061.2349.14FalseNoneNoneFalseNoneFalse101288.84220
3089510106226Nonecode110Providing & fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top & bottom rails, covered with heat moulded PVC C channel of 5mm thick sheet & 30 x 50mm wide to form stiles & 5mm thick & 75mm wide PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the stiles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm Aluminium hinges Frist Floor Complete specification as per engineer in charge.Sqm2081.842081.8472.765FalseNoneNoneFalseNoneFalse151485.08760
3089511106226Nonecode111Providing & fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top & bottom rails, covered with heat moulded PVC C channel of 5mm thick sheet & 30 x 50mm wide to form stiles & 5mm thick & 75mm wide PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the stiles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm Aluminium hinges Second Floor Complete specification as per engineer in charge.Sqm2102.462102.4635.91FalseNoneNoneFalseNoneFalse75499.33860
3089512106226Nonecode112Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. Ground Floor Complete specification as per engineer in charge.Cum179220.06179220.065.29FalseNoneNoneFalseNoneFalse948074.11740
3089513106226Nonecode113Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications Frist Floor Complete specification as per engineer in charge.Cum181012.26181012.261.021FalseNoneNoneFalseNoneFalse184813.517460
3089514106226Nonecode114Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Second Floor Complete specification as per engineer in charge.Cum182804.46182804.460.143FalseNoneNoneFalseNoneFalse26141.037780
3089515106226Nonecode115Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ) Ground Floor Complete specification as per engineer in charge.Sqm9662.329662.32166.77FalseNoneNoneFalseNoneFalse1611385.10640
3089516106226Nonecode116Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ) Frist Floor Complete specification as per engineer in charge.Sqm9758.959758.9528.56FalseNoneNoneFalseNoneFalse278715.6120
3089517106226Nonecode117Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ) Second Floor Complete specification as per engineer in charge.Sqm9855.579855.576.72FalseNoneNoneFalseNoneFalse66229.43040
3089518106226Nonecode118Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. Ground Floor Complete specification as per engineer in charge.Each71.3971.39366.0FalseNoneNoneFalseNoneFalse26128.740
3089519106226Nonecode119Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc.Frist Floor Complete specification as per engineer in charge.Each72.1172.1172.0FalseNoneNoneFalseNoneFalse5191.920
3089520106226Nonecode120Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. Second Floor Complete specification as per engineer in charge.Each72.8272.8218.0FalseNoneNoneFalseNoneFalse1310.760
3089521106226Nonecode121Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. Ground Floor Complete specification as per engineer in charge.Each1365.51365.562.0FalseNoneNoneFalseNoneFalse84661.00
3089522106226Nonecode122Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. Frist Floor Complete specification as per engineer in charge.Each1379.171379.1712.0FalseNoneNoneFalseNoneFalse16550.040
3089523106226Nonecode123Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. Second Floor Complete specification as per engineer in charge.Each1392.821392.823.0FalseNoneNoneFalseNoneFalse4178.460
3089524106226Nonecode124Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete Ground Floor Complete specification as per engineer in charge.Each168.74168.74126.0FalseNoneNoneFalseNoneFalse21261.240
3089525106226Nonecode125Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete Frist Floor Complete specification as per engineer in charge.Each170.42170.4224.0FalseNoneNoneFalseNoneFalse4090.080
3089526106226Nonecode126Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeSecond Floor Complete specification as per engineer in charge.Each172.12172.126.0FalseNoneNoneFalseNoneFalse1032.720
3089527106226Nonecode127Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge..Kg176.53176.5310944.0FalseNoneNoneFalseNoneFalse1931944.320
3089528106226Nonecode128Earth work excavation for pipeline trenches in all kinds of soils bymechanical means above 600 mm trench width as per drawing andtechnical specifications, including setting out, construction of shoring,strutting, barricading, caution lights, bracing, using sight rails & boningrods at every 100 mm whevere necessary as directed, removal ofstumps and other deleterious matter, dressing of sides and levellingthe bottom of trench to the extent required , utilising the availableexcavated earth locally for the work etc., and all other appurtenancescomplete in the following strata. Complete specification as per engineer in charge.Cum340.08340.0860.63FalseNoneNoneFalseNoneFalse20619.05040
3089529106226Nonecode129Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5m.Including cost of all labour complete as per specifications.Complete specification as per engineer in charge.Cum207.68207.6887.0FalseNoneNoneFalseNoneFalse18068.160
3089530106226Nonecode130Supplying, fitting and placing Mild Steel Reinforcement complete as per drawing and technical specification..Complete specification as per engineer in charge.Tonne95679.4895679.481.38FalseNoneNoneFalseNoneFalse132037.68240
3089531106226Nonecode131Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm481.56481.56784.643FalseNoneNoneFalseNoneFalse377852.683080
3089532106226Nonecode132Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.. Ground Floor Complete specification as per engineer in charge.Sqm3701.93701.9919.0FalseNoneNoneFalseNoneFalse3402046.10
3089533106226Nonecode133Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. First Floor Complete specification as per engineer in charge.Sqm3738.933738.931837.336FalseNoneNoneFalseNoneFalse6869670.690480
3089534106226Nonecode134Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. Second Floor Complete specification as per engineer in charge.Sqm3775.953775.951125.545FalseNoneNoneFalseNoneFalse4250001.642750
3089535106226Nonecode135Providing and supplying 'Acoustical Wall Paneling' with square edges made of fibre glass substrate 25mm thick and wrapped on the front side with an acoustically transparent and classified for Fire reaction Class A, as per ASTM E-84, fabric with option of colors - as per the choice of the itect/Engineer incharge of the size 600x600mm, 600x1200mm & 600x1800mm providing a minimum sound tionlevel of 0.85 NRC to be affixed to wall using Wall panel lmpaler sand construction adhesives as per the tions laid down by the certified manufacturer. Complete specification as per engineer in charge.Sqm7433.657433.65119.285FalseNoneNoneFalseNoneFalse886722.940250
3089536106226Nonecode136Providing and Constructing standard rubber flooring for indoor area using rubber member of 12mm to 16mm thick, to be layed over prepared cement mortar /concrete surface using CM 1:6 beneath rubber membraine including cost of all materials, labour, packing joints and mortor finishing curing, all lead and lift, transportation and also including all applicable taxes complete as per direction incharge of work Complete specification as per engineer in charge.Sqm5713.565713.5655.038FalseNoneNoneFalseNoneFalse314462.915280
3089537106226Nonecode137Providing and fixing 6mm Clear/opal white/solar bronze/blue/green tinted Multi wall poly carbonate sheet for Tubular structure. The work including cost of all materials, labour charges and usage charges of machinery for cutting, welding, grinding and erection equipments, with all lead, transportation, loading and unloading and all other incidental charges etc. complete as per specification and directions of the Engineer in charge of the work.Cum4056.254056.25490.5FalseNoneNoneFalseNoneFalse1989590.6250
3089538106226Nonecode138Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-logenated FR grade mineral based polymer ( 2 hrs fire resist ance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sand wiched between 0.50 skins thick aluminium sheet making a total panel hickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service oating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete For Straight Portion Ground Floor Complete specification as per engineer in charge.Sqm5177.735177.73342.78FalseNoneNoneFalseNoneFalse1774822.28940
3089539106226Nonecode139Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-logenated FR grade mineral based polymer ( 2 hrs fire resist ance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sand wiched between 0.50 skins thick aluminium sheet making a total panel hickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service oating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete For Straight Portion First Floor Complete specification as per engineer in charge.Sqm5229.515229.51441.0FalseNoneNoneFalseNoneFalse2306213.910
3089540106226Nonecode140Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm190.81190.8138137.59FalseNoneNoneFalseNoneFalse7277033.54790
3089541106226Nonecode141Providing and fixing RCC precast cover slab of 250 mm thick for drain in cement concrete M20 using graded granite jelly 20mm and down size with steel reinforcement, including formwork, lift charges, curing and concrete finished surfaces on both sides etc., complete as per drawing and directions of engineer-in-charge.Sqm5192.05192.032.4FalseNoneNoneFalseNoneFalse168220.80
3089542106226Nonecode142Providing and laying 100mm thick pre-cast cover slabs over drains & Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete.Complete specification as per engineer in charge.Sqm1204.551204.55178.2FalseNoneNoneFalseNoneFalse214650.810
3089543106226Nonecode143Providing and fixing pre cast solid cement concrete kerb stones made out of M20 with top and bottom width 114 and 165mm respectively, 400mm high and 450 mm in length finished with CM 1:3 plastering and finishing cutting including formwork, curing including cost of materials, labour charges of machinery, loading and unloading, Lead and Lift, Transportation etc., complete as directed by the Engineer in Charge of the work.Nos383.5383.52178.66FalseNoneNoneFalseNoneFalse835516.110
3089544106226Nonecode144Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces Complete specification as per engineer in charge.Sqm141.48141.48343.0FalseNoneNoneFalseNoneFalse48527.640
3089545106226Nonecode145Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 m3in volume and stock piling at designated locations and disposal of dismantled materials and stacking serviceable and unserviceable materials separately Complete specification as per engineer in charge.Cum730.78730.78266.775FalseNoneNoneFalseNoneFalse194953.83450
3089546106226Nonecode146Construction of Granular Sub-Base of required grading as per design mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401. For Grading -V Material.Complete specification as per engineer in charge.Cum3228.133228.13375.0FalseNoneNoneFalseNoneFalse1210548.750
3089547106226Nonecode147Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 14:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 140 kg/ m3 , optimum moisture content to be determined during trial length construction, concrete strength not to be less than 7 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing. Complete specification as per engineer in charge.Cum6386.166386.16429.097FalseNoneNoneFalseNoneFalse2740282.097520
3089548106226Nonecode148Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383:2016:, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, primer, sealant, curing of concrete slabs for 14-days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work.Cum8792.668792.66515.654FalseNoneNoneFalseNoneFalse4533970.299640
3089549106226Nonecode149Lead for disposal of Earth & Debris shall be payable including loading and unloading up to 15kms . Complete specification as per engineer in charge.Cum177.82177.82463.775FalseNoneNoneFalseNoneFalse82468.47050
3089550106226Nonecode150Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Ground Floor Complete specification as per engineer in charge.Sqm1700.381700.385464.005FalseNoneNoneFalseNoneFalse9290884.82190
3089551106226Nonecode151Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. First Floor Complete specification as per engineer in charge.Sqm1717.391717.394919.689FalseNoneNoneFalseNoneFalse8449024.691710
3089552106226Nonecode152Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Second Floor Complete specification as per engineer in charge.Sqm1734.391734.392103.619FalseNoneNoneFalseNoneFalse3648495.757410
3089553106226Nonecode153Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Ground Floor Complete specification as per engineer in charge.Sqm1433.01433.0387.1FalseNoneNoneFalseNoneFalse554714.30
3089554106226Nonecode154Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.. First Floor Complete specification as per engineer in charge.Sqm1447.331447.33847.35FalseNoneNoneFalseNoneFalse1226395.07550
3089555106226Nonecode155Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications..) Second Floor Complete specification as per engineer in charge.Sqm1461.661461.66440.471FalseNoneNoneFalseNoneFalse643818.841860
3089556106226Nonecode156Providing 20 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/ stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing .Ground Floor Complete specification as per engineer in charge.Sqm556.85556.852738.86FalseNoneNoneFalseNoneFalse1525134.1910
3089557106226Nonecode157Providing 20 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/ stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing . First Floor Complete specification as per engineer in charge.Sqm562.42562.422635.42FalseNoneNoneFalseNoneFalse1482212.91640
3089558106226Nonecode158Providing 20 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/ stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing .Second Floor Complete specification as per engineer in charge.Sqm567.99567.991164.596FalseNoneNoneFalseNoneFalse661478.882040
3089559106226Nonecode159Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing First Floor Complete specification as per engineer in charge.Sqm464.09464.092422.6FalseNoneNoneFalseNoneFalse1124304.4340
3089560106226Nonecode160Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing .Ground FloorSqm475.07475.072454.843FalseNoneNoneFalseNoneFalse1166222.264010
3089561106226Nonecode161Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing First Floor Complete specification as per engineer in charge.Sqm479.83479.832271.95FalseNoneNoneFalseNoneFalse1090149.76850
3089562106226Nonecode162Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Second FloorSqm484.58484.581622.993FalseNoneNoneFalseNoneFalse786469.947940
3089563106226Nonecode163Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in-charge.Ground FloorSqm419.26419.262769.449FalseNoneNoneFalseNoneFalse1161119.187740
3089564106226Nonecode164Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in-charge. First FloorSqm423.46423.461949.315FalseNoneNoneFalseNoneFalse825456.92990
3089565106226Nonecode165Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in-charge. Second FloorSqm427.65427.65872.901FalseNoneNoneFalseNoneFalse373296.112650
3089566106226Nonecode166Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:3 (1 cement: 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Ground FloorSqm475.07475.07328.122FalseNoneNoneFalseNoneFalse155880.918540
3089567106226Nonecode167Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:3 (1 cement: 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. First FloorSqm479.83479.831093.287FalseNoneNoneFalseNoneFalse524591.901210
3089568106226Nonecode168Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:3 (1 cement: 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.) Second FloorSqm484.58484.581119.102FalseNoneNoneFalseNoneFalse542294.447160
3089569106226Nonecode169Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ground FloorSqm362.15362.15489.834FalseNoneNoneFalseNoneFalse177393.38310
3089570106226Nonecode170Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. First FloorSqm365.77365.77620.25FalseNoneNoneFalseNoneFalse226868.84250
3089571106226Nonecode171Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Ground FloorSqm115.53115.531669.225FalseNoneNoneFalseNoneFalse192845.564250
3089572106226Nonecode172Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.First FloorSqm116.68116.681580.984FalseNoneNoneFalseNoneFalse184469.213120
3089573106226Nonecode173Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Second FloorSqm117.84117.84698.764FalseNoneNoneFalseNoneFalse82342.349760
3089574106226Nonecode174Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Ground FloorSqm1744.521744.52322.0FalseNoneNoneFalseNoneFalse561735.440
3089575106226Nonecode175Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc.Complete specification as per engineer in charge.. First FloorSqm1761.971761.971537.84FalseNoneNoneFalseNoneFalse2709627.94480
3089576106226Nonecode176Providing and fixing 20mm thick gang saw water cut Lakared granite for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a coat of rough plastering using CM 1:4 (1 cement : 4 fine sand), cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, grooves in joints including cost of curing etc., complete including cost and conveyance of all materials, mortar, labour for all items of work, usage charges of machinery etc.,Complete specification as per engineer in charge..First FloorSqm4728.714728.71935.5FalseNoneNoneFalseNoneFalse4423708.2050
3089577106226Nonecode177Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour,Complete specification as per engineer in charge..Ground FloorSqm1880.811880.81465.06FalseNoneNoneFalseNoneFalse874689.49860
3089578106226Nonecode178Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour,Complete specification as per engineer in charge.. First FloorSqm1899.621899.62706.458FalseNoneNoneFalseNoneFalse1342001.745960
3089579106226Nonecode179Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour,Complete specification as per engineer in charge.. Second FloorSqm1918.431918.43403.02FalseNoneNoneFalseNoneFalse773165.65860
3089580106226Nonecode180Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 (1 cement : 3 coarse sand) proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar, labour, curing etc., complete..Ground Floor Complete specification as per engineer in charge.Sqm4359.994359.99199.134FalseNoneNoneFalseNoneFalse868222.248660
3089581106226Nonecode181Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 (1 cement : 3 coarse sand) proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar, labour, curing etc., complete.First Floor Complete specification as per engineer in charge.Sqm4403.594403.59772.947FalseNoneNoneFalseNoneFalse3403741.679730
3089582106226Nonecode182Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 (1 cement : 3 coarse sand) proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar, labour, curing etc., complete Second Floor Complete specification as per engineer in charge.Sqm4447.194447.19830.019FalseNoneNoneFalseNoneFalse3691252.196610
3089583106226Nonecode183Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. Ground Floor Complete specification as per engineer in charge.Kgs237.54237.54913.41FalseNoneNoneFalseNoneFalse216971.41140
3089584106226Nonecode184Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. First Floor Complete specification as per engineer in charge.Kgs239.92239.921358.73FalseNoneNoneFalseNoneFalse325986.50160
3089585106226Nonecode185Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. Second Floor Complete specification as per engineer in charge.Kgs242.29242.29995.94FalseNoneNoneFalseNoneFalse241306.30260
3089586106226Nonecode186Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding Ground Floor Complete specification as per engineer in charge.Kgs218.07218.073387.33FalseNoneNoneFalseNoneFalse738675.05310
3089587106226Nonecode187Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding First Floor Complete specification as per engineer in charge.Kgs220.25220.251977.39FalseNoneNoneFalseNoneFalse435520.14750
3089588106226Nonecode188Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. Complete specification as per engineer in charge.Sqm1038.41038.41750.0FalseNoneNoneFalseNoneFalse1817200.00
3089589106226Nonecode189Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Ground FloorKgs733.37733.372006.45FalseNoneNoneFalseNoneFalse1471470.23650
3089590106226Nonecode190Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.First FloorKgs740.71740.711081.35FalseNoneNoneFalseNoneFalse800966.75850
3089591106226Nonecode191Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Ground Floor.Second FloorKgs748.04748.041083.6FalseNoneNoneFalseNoneFalse810576.1440
3089592106226Nonecode192Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, griding the edge to half/full round wherever required, labour, curing Complete specification as per engineer in charge.Sqm1209.741209.74344.08FalseNoneNoneFalseNoneFalse416247.33920
3089593106226Nonecode193Frabricating, providing and erecting in position of MS Hot Dipped Galvanized sq rods sq hallow poles of 132x132 heavy guage of length 300mm with MS. Hot Dipped galvanized grill work as per approved design and drawing of cheif architect using 12x75mm galvanised Flat for all round frames and 0mmx20mm galvanized forged design with Square for vertical at 150mmc/c as shown in drawing including providing forged ornamental arrowed at top and bottom the work is 16 inclusive of howrowing filat sq rods placing welding all the joints, incudung grinding finishing two coats of anticorrosive paintover one coat of metal primer. The rate inclusive of all material like MS Hallow galvanoised pipe flats forged sq rods cost of labour for all items of work cost painting welding cutting grinding with all lead and ift as per specification including loading and unloading with cost and convey of all material labour machinery and incidental charges for succesfull completion of work as per direction engineer incharge of the work. Complete specification as per engineer in charge.Sqm10789.9210789.92127.25FalseNoneNoneFalseNoneFalse1373017.320
3089594106226Nonecode194SUPREME BENCH: Made out of Sadarahally Grey stone with 2 stands with strong base with back slab (Support) with machine cutting top slab mirror polish with 300mm seating slab with 4 line finishing Complete specification as per engineer in charge.Nos18408.018408.030.0FalseNoneNoneFalseNoneFalse552240.00
3089595106226Nonecode195Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by and lift upto 1.5 m including cost of labour, tools, usage& other ramming and watering appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m. Complete specification as per engineer in charge.Cum628.24628.2436.0FalseNoneNoneFalseNoneFalse22616.640
3089596106226Nonecode196Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured.Ground Floor Complete specification as per engineer in charge.Kgs733.37733.37180.0FalseNoneNoneFalseNoneFalse132006.60
3089597106226Nonecode197Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured. First Floor Complete specification as per engineer in charge.Kgs740.71740.71180.0FalseNoneNoneFalseNoneFalse133327.80
3089598106226Nonecode198Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured. Second Floor Complete specification as per engineer in charge.Kgs748.04748.04180.0FalseNoneNoneFalseNoneFalse134647.20
3089599106226Nonecode199Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in-Charge.Ground FloorKgs179.13179.13168.75FalseNoneNoneFalseNoneFalse30228.18750
3089600106226Nonecode200Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in-Charge.(KPWD SR 2023-24, First FloorKgs180.92180.9267.5FalseNoneNoneFalseNoneFalse12212.10
3089601106226Nonecode201Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately Complete specification as per engineer in charge.Each11.9211.9210000.0FalseNoneNoneFalseNoneFalse119200.00
3089602106226Nonecode202Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. 2 HP, Size 65x50 Head 13M, Discharge 462 LPM Complete specification as per engineer in charge.Each20261.7820261.785.0FalseNoneNoneFalseNoneFalse101308.90
3089603106226Nonecode203Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls Wherever require: White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps Ground FloorEach3720.073720.0721.0FalseNoneNoneFalseNoneFalse78121.470
3089604106226Nonecode204Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls Wherever require: White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps First Floor Complete specification as per engineer in charge.Each3757.283757.2813.0FalseNoneNoneFalseNoneFalse48844.640
3089605106226Nonecode205Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls Wherever require: White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps Second Floor Complete specification as per engineer in charge.Each3794.483794.489.0FalseNoneNoneFalseNoneFalse34150.320
3089606106226Nonecode206Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid. Ground Floor Complete specification as per engineer in charge.Nos7758.157758.1528.0FalseNoneNoneFalseNoneFalse217228.20
3089607106226Nonecode207Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid. First Floor Complete specification as per engineer in charge.Nos7835.747835.7420.0FalseNoneNoneFalseNoneFalse156714.80
3089608106226Nonecode208Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid. Second Floor Complete specification as per engineer in charge.Nos7913.327913.3212.0FalseNoneNoneFalseNoneFalse94959.840
3089609106226Nonecode209Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :14.5.1 Single half stall urinal with 5 litre P.V.C. automatic flushing cisternvol 5 Complete specification as per engineer in charge.Each11217.3211217.325.0FalseNoneNoneFalseNoneFalse56086.60
3089610106226Nonecode210Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge Concealed work, including cutting chases and making good the walls etc. 15mm nominal dia pipes.Complete specification as per engineer in charge.Mtr401.09401.09435.0FalseNoneNoneFalseNoneFalse174474.150
3089611106226Nonecode211Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge Concealed work, including cutting chases and making good the walls etc. 20mm nominal dia pipes.Complete specification as per engineer in charge.Mtr491.95491.95435.0FalseNoneNoneFalseNoneFalse213998.250
3089612106226Nonecode212Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge Concealed work, including cutting chases and making good the walls etc. 25mm nominal dia pipes.Complete specification as per engineer in charge.Mtr619.15619.15355.0FalseNoneNoneFalseNoneFalse219798.250
3089613106226Nonecode213Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge Concealed work, including cutting chases and making good the walls etc. 32mm nominal dia pipes.Complete specification as per engineer in charge.Mtr722.99722.99265.0FalseNoneNoneFalseNoneFalse191592.350
3089614106226Nonecode214Constructing brick masonry chamber of internal dimension 600x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.Complete specification as per engineer in charge.Each6218.726218.7232.0FalseNoneNoneFalseNoneFalse198999.040
3089615106226Nonecode215Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc HDPE Grade PE100-PN6.0,200mm dia.Complete specification as per engineer in charge.Mtr1599.141599.14280.0FalseNoneNoneFalseNoneFalse447759.20
3089616106226Nonecode216Providing and fixing brass bib cock of approved quality : 20 mm nominal bore Complete specification as per engineer in charge.Each395.89395.89125.0FalseNoneNoneFalseNoneFalse49486.250
3089617106226Nonecode217Providing and fixing brass stop cock of approved quality : 20 mm nominal bore.Complete specification as per engineer in charge.Each395.89395.8964.0FalseNoneNoneFalseNoneFalse25336.960
3089618106226Nonecode218providing and fixing square-mouth S. W. gully trap class SP-1 complete with C.1. grating brick masonry chamber 150 x100 mm size P type With Non Modular common burnt clay bricks of designation 3.5 & with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover t5 be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design Complete specification as per engineer in charge.Each3350.143350.1454.0FalseNoneNoneFalseNoneFalse180907.560
3089619106226Nonecode219Providing and fixing PTMT grating of approved quality and colour Circular type 100 mm nominal dia. Complete specification as per engineer in charge.Nos53.2253.2244.0FalseNoneNoneFalseNoneFalse2341.680
3089620106226Nonecode220Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Ground Floor Complete specification as per engineer in charge.Each1583.561583.5640.0FalseNoneNoneFalseNoneFalse63342.40
3089621106226Nonecode221Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers Complete specification as per engineer in charge.Each1727.521727.522.0FalseNoneNoneFalseNoneFalse3455.040
3089622106226Nonecode222Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and Cover Complete specification as per engineer in charge.Each7079.37079.310.0FalseNoneNoneFalseNoneFalse70793.00
3089623106226Nonecode223Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For:10.1.1 PVC pipes 25mm dia, 10 kg/sqcm & class 5 Complete specification as per engineer in charge.Mtr62.362.3500.0FalseNoneNoneFalseNoneFalse31150.00
3089624106226Nonecode224Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For:10.1.2 PVC pipes 32mm dia., 10 kg/sqcm & class 5 Complete specification as per engineer in charge.Mtr86.9786.97500.0FalseNoneNoneFalseNoneFalse43485.00
3089625106226Nonecode225Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For:PVC pipes 110mm dia 6 kg /sqcm class 3 Complete specification as per engineer in charge.Mtr533.48533.48255.0FalseNoneNoneFalseNoneFalse136037.40
3089626106226Nonecode226Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For:10.1.2 PVC pipes 140mm, 6 kg/sqcm & class 3 Complete specification as per engineer in charge.Mtr758.04758.0460.0FalseNoneNoneFalseNoneFalse45482.40
3089627106226Nonecode227Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe around to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 25mm dia, 10 kg/sqcm & class 5. Complete specification as per engineer in charge.m62.362.3130.0FalseNoneNoneFalseNoneFalse8099.00
3089628106226Nonecode228Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.25 mm dia 2 mm thick Complete specification as per engineer in charge.Mtr81.4281.42750.0FalseNoneNoneFalseNoneFalse61065.00
3089629106226Nonecode229Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.25 mm dia 2 mm thick Complete specification as per engineer in charge.Mtr95.5895.58125.0FalseNoneNoneFalseNoneFalse11947.50
3089630106226Nonecode230Concealed Conduit System: Supplying …. Mm dia 2mm2.5mm Thick heavy gauge PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive paste etc… and running before concreting th eslab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be convered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary 19/20mm dia 2mm thick Complete specification as per engineer in charge.Mtr77.8877.881190.0FalseNoneNoneFalseNoneFalse92677.20
3089631106226Nonecode231Concealed Conduit System: Supplying …. Mm dia 2mm2.5mm Thick heavy gauge PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive paste etc… and running before concreting th eslab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be convered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary 25mm dia 2mm thick Complete specification as per engineer in charge.Mtr92.0492.04955.0FalseNoneNoneFalseNoneFalse87898.20
3089632106226Nonecode232Concealed Conduit System: Supplying …. Mm dia 2mm2.5mm Thick heavy gauge PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive paste etc… and running before concreting th eslab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be convered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary 32mm dia 2.5mm thickMtr121.54121.541300.0FalseNoneNoneFalseNoneFalse158002.00
3089633106226Nonecode233PVC pipe-50mm dia Complete specification as per engineer in charge.Mtr103.84103.841745.0FalseNoneNoneFalseNoneFalse181200.80
3089634106226Nonecode234PVC pipe-75mm dia Complete specification as per engineer in charge.Mtr160.48160.481025.0FalseNoneNoneFalseNoneFalse164492.00
3089635106226Nonecode235PVC pipe-100mm dia Complete specification as per engineer in charge.Mtr256.06256.06870.0FalseNoneNoneFalseNoneFalse222772.20
3089636106226Nonecode236Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19/20 mm dia 2 mm thick Complete specification as per engineer in charge.Mtr80.2480.24501.0FalseNoneNoneFalseNoneFalse40200.240
3089637106226Nonecode237Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25 mm dia 2 mm thick Complete specification as per engineer in charge.Mtr93.2293.22360.0FalseNoneNoneFalseNoneFalse33559.20
3089638106226Nonecode238Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 32 mm dia 2.5 mm thick Complete specification as per engineer in charge.Mtr116.82116.82415.0FalseNoneNoneFalseNoneFalse48480.30
3089639106226Nonecode239Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 40 mm dia 2.5 mm thick Complete specification as per engineer in charge.Mtr164.02164.02260.0FalseNoneNoneFalseNoneFalse42645.20
3089640106226Nonecode240Supplying and wiring adopting loop system in existing pvc conduit/casing caping using 1100v grade,COPPER conducter flexible multistrand FRLS PVC insulated,2x1.5Sq.mm Cable confirming to the GTP without switch,the other end of the wire shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Point wiring using Copper wire without Switch. Short point upto 3Mtr from tapping point to out let via switch box Complete specification as per engineer in charge.Nos317.42317.42230.0FalseNoneNoneFalseNoneFalse73006.60
3089641106226Nonecode241Supplying and wiring adopting loop system in existing pvc conduit/casing caping using 1100v grade,COPPER conducter flexible multistrand FRLS PVC insulated,2x1.5Sq.mm Cable confirming to the GTP without switch,the other end of the wire shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Point wiring using Copper wire without Switch. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box Complete specification as per engineer in charge.Nos447.22447.22142.0FalseNoneNoneFalseNoneFalse63505.240
3089642106226Nonecode242Supplying and wiring adopting loop system in existing pvc conduit/casing caping using 1100v grade,COPPER conducter flexible multistrand FRLS PVC insulated,2x1.5Sq.mm Cable confirming to the GTP without switch,the other end of the wire shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Point wiring using Copper wire without Switch. Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box Complete specification as per engineer in charge.Nos654.9654.9214.0FalseNoneNoneFalseNoneFalse140148.60
3089643106226Nonecode243Supplying and wiring adopting loop system in existing pvc conduit/casing caping using 1100v grade,COPPER conducter flexible multistrand FRLS PVC insulated,2x1.5Sq.mm Cable confirming to the GTP without switch,the other end of the wire shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Point wiring using Copper wire without Switch.Two outlet in a row,above 3Mtr upto 6Mtr from tapping point to out let via switchesComplete specification as per engineer in charge.Nos798.86798.8666.0FalseNoneNoneFalseNoneFalse52724.760
3089644106226Nonecode244Supplying and wiring adopting loop system in existing pvc conduit/casing caping using 1100v grade,COPPER conducter flexible multistrand FRLS PVC insulated,2x1.5Sq.mm Cable confirming to the GTP without switch,the other end of the wire shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Point wiring using Copper wire without Switch.Three outlet in a row, above 6Mts upto 10Mtr from tapping point to out let via switches box Complete specification as per engineer in charge.Nos1167.021167.0255.0FalseNoneNoneFalseNoneFalse64186.10
3089645106226Nonecode245Suppling and fixing PVC/metal conduit deep juction boxes 19/20mm deep juction box Complete specification as per engineer in charge.Each57.8257.8265.0FalseNoneNoneFalseNoneFalse3758.30
3089646106226Nonecode246Suppling and fixing PVC/metal conduit deep juction boxes 25mm deep juction boxComplete specification as per engineer in charge.Each66.0866.0875.0FalseNoneNoneFalseNoneFalse4956.00
3089647106226Nonecode247Suppling and fixing PVC/metal conduit deep juction boxes 32mm deep juction box Complete specification as per engineer in charge.Each71.9871.9875.0FalseNoneNoneFalseNoneFalse5398.50
3089648106226Nonecode248Suppling and fixing PVC/metal conduit deep juction boxes Suplay and fixing Metal Fan Box with Round Hook Complete specification as per engineer in charge.Each138.06138.06105.0FalseNoneNoneFalseNoneFalse14496.30
3089649106226Nonecode249Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3Way Complete specification as per engineer in charge.Each162.84162.84115.0FalseNoneNoneFalseNoneFalse18726.60
3089650106226Nonecode250Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way Complete specification as per engineer in charge.Each208.86208.8685.0FalseNoneNoneFalseNoneFalse17753.10
3089651106226Nonecode251Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6 Way Complete specification as per engineer in charge.Each259.6259.685.0FalseNoneNoneFalseNoneFalse22066.00
3089652106226Nonecode252Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8Way Complete specification as per engineer in charge.Each307.98307.9832.0FalseNoneNoneFalseNoneFalse9855.360
3089653106226Nonecode253Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way Complete specification as per engineer in charge.Each376.42376.4235.0FalseNoneNoneFalseNoneFalse13174.70
3089654106226Nonecode254Wiring for lighting /power circuit using one of PVC insulated 1100v grade,multis and Copper conductor single core cable in open or consealed system of wiring.1.5 sqmmComplete specification as per engineer in charge.Mtr30.6830.685300.0FalseNoneNoneFalseNoneFalse162604.00
3089655106226Nonecode255Wiring for lighting /power circuit using one of PVC insulated 1100v grade,multis and Copper conductor single core cable in open or consealed system of wiring. 2.5 sqmm Complete specification as per engineer in charge.Mtr49.5649.567900.0FalseNoneNoneFalseNoneFalse391524.00
3089656106226Nonecode256Wiring for lighting /power circuit using one of PVC insulated 1100v grade,multis and Copper conductor single core cable in open or consealed system of wiring) 4 sqmmComplete specification as per engineer in charge.Mtr74.3474.344445.0FalseNoneNoneFalseNoneFalse330441.30
3089657106226Nonecode257Wiring for lighting /power circuit using one of PVC insulated 1100v grade,multis and Copper conductor single core cable in open or consealed system of wiring 6 sqmm Complete specification as per engineer in charge.Mtr108.56108.564458.0FalseNoneNoneFalseNoneFalse483960.480
3089658106226Nonecode258Wiring for lighting /power circuit using one of PVC insulated 1100v grade,multis and Copper conductor single core cable in open or consealed system of wiring.10 sqmm Complete specification as per engineer in charge.Mtr197.06197.0675.0FalseNoneNoneFalseNoneFalse14779.50
3089659106226Nonecode259Supplying and fixing of modular switch/Socket/stepped electeonic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.6A mps one wayComplete specification as per engineer in charge.Each120.36120.36504.0FalseNoneNoneFalseNoneFalse60661.440
3089660106226Nonecode260Supplying and fixing of modular switch/Socket/stepped electeonic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. 6A mps Two way Complete specification as per engineer in charge.Each195.88195.88185.0FalseNoneNoneFalseNoneFalse36237.80
3089661106226Nonecode261Supplying and fixing of modular switch/Socket/stepped electeonic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Stepped fan regulator.Complete specification as per engineer in charge.Each421.26421.26175.0FalseNoneNoneFalseNoneFalse73720.50
3089662106226Nonecode262Supplying and fixing of modular switch/Socket/stepped electeonic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.16Amps one way switch Complete specification as per engineer in charge.Each212.4212.494.0FalseNoneNoneFalseNoneFalse19965.60
3089663106226Nonecode263Supplying and fixing of modular switch/Socket/stepped electeonic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.32A DP Switch Complete specification as per engineer in charge.Each384.68384.6860.0FalseNoneNoneFalseNoneFalse23080.80
3089664106226Nonecode264Supplying and fixing of modular switch/Socket/stepped electeonic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. 6/16Amps univeral socket Complete specification as per engineer in charge.Each278.48278.4884.0FalseNoneNoneFalseNoneFalse23392.320
3089665106226Nonecode265Supplying and fixing superior gality modular switch mounting polycorbonate plate with neceaary supporting back plate with rquired nos. of machine screwes, bolts nuts etc., complete on the existing metal/PVC box.. 1 to 3 Module Complete specification as per engineer in charge.Each161.66161.6685.0FalseNoneNoneFalseNoneFalse13741.10
3089666106226Nonecode266Supplying and fixing superior gality modular switch mounting polycorbonate plate with neceaary supporting back plate with rquired nos. of machine screwes, bolts nuts etc., complete on the existing metal/PVC box.. 4 Module Complete specification as per engineer in charge.Each206.5206.583.0FalseNoneNoneFalseNoneFalse17139.50
3089667106226Nonecode267Supplying and fixing superior gality modular switch mounting polycorbonate plate with neceaary supporting back plate with rquired nos. of machine screwes, bolts nuts etc., complete on the existing metal/PVC box. 6 Module Complete specification as per engineer in charge.Each276.12276.1286.0FalseNoneNoneFalseNoneFalse23746.320
3089668106226Nonecode268Supplying and fixing superior gality modular switch mounting polycorbonate plate with neceaary supporting back plate with rquired nos. of machine screwes, bolts nuts etc., complete on the existing metal/PVC box..8 Module Complete specification as per engineer in charge.Each335.12335.1252.0FalseNoneNoneFalseNoneFalse17426.240
3089669106226Nonecode269Supplying and fixing superior gality modular switch mounting polycorbonate plate with neceaary supporting back plate with rquired nos. of machine screwes, bolts nuts etc., complete on the existing metal/PVC box.. 10-12 Module Complete specification as per engineer in charge.Each405.92405.9256.0FalseNoneNoneFalseNoneFalse22731.520
3089670106226Nonecode270Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.5.18.1 6-32 A SP Complete specification as per engineer in charge.Each489.7489.745.0FalseNoneNoneFalseNoneFalse22036.50
3089671106226Nonecode271Supplying and fixing regular MCB distribution boards on wall/ woodboard /flush mounting required clamps,bolts,nuts etc.. with provision for fixing suitable type capacity MCB's single phase /3 phase /single door with powder coated painting etc., complete 8Way SP & N Complete specification as per engineer in charge.Each2187.722187.7216.0FalseNoneNoneFalseNoneFalse35003.520
3089672106226Nonecode272Supplying and fixing regular MCB distribution boards on wall/ woodboard /flush mounting required clamps,bolts,nuts etc.. with provision for fixing suitable type capacity MCB's single phase /3 phase /single door with powder coated painting etc., complete12Way SP & N Complete specification as per engineer in charge.Each2748.222748.2210.0FalseNoneNoneFalseNoneFalse27482.20
3089673106226Nonecode273Supplying and fixing regular MCB distribution boards on wall/ woodboard /flush mounting required clamps,bolts,nuts etc.. with provision for fixing suitable type capacity MCB's single phase /3 phase /single door with powder coated painting etc., complete 4Way TP & N Complete specification as per engineer in charge.Each4764.844764.8410.0FalseNoneNoneFalseNoneFalse47648.40
3089674106226Nonecode274Supplying and fixing regular MCB distribution boards on wall/ woodboard /flush mounting required clamps,bolts,nuts etc.. with provision for fixing suitable type capacity MCB's single phase /3 phase /single door with powder coated painting etc., complete 6Way TP & N Complete specification as per engineer in charge.Each5829.25829.210.0FalseNoneNoneFalseNoneFalse58292.00
3089675106226Nonecode275Supplying and fixing and wiring Earth Leakage Miniature Circuit Breaker [RCCB] 240/450V up 300mA sensitivity on exsiting wood/panel board. 32-40 Amps 2 Pole Complete specification as per engineer in charge.Each5379.625379.6213.0FalseNoneNoneFalseNoneFalse69935.060
3089676106226Nonecode276Supplying and fixing and wiring Earth Leakage Miniature Circuit Breaker [RCCB] 240/450V up 300mA sensitivity on exsiting wood/panel board.32-40 Amps 4 Pole Complete specification as per engineer in charge.Each6073.466073.4612.0FalseNoneNoneFalseNoneFalse72881.520
3089677106226Nonecode277Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia Complete specification as per engineer in charge.Each4141.84141.813.0FalseNoneNoneFalseNoneFalse53843.40
3089678106226Nonecode278Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.Complete specification as per engineer in charge.Each5022.085022.0812.0FalseNoneNoneFalseNoneFalse60264.960
3089679106226Nonecode279Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. GI strip ((7.3.2)25x6mm) Complete specification as per engineer in charge.Mtr151.04151.041370.0FalseNoneNoneFalseNoneFalse206924.80
3089680106226Nonecode280Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. Copper strip ((7.3.6)25x3mm) Complete specification as per engineer in charge.Mtr672.6672.62080.0FalseNoneNoneFalseNoneFalse1399008.00
3089681106226Nonecode281Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. Copper strip ((7.22.6)8SWG copper wire)Complete specification as per engineer in charge.Mtr257.24257.241255.0FalseNoneNoneFalseNoneFalse322836.20
3089682106226Nonecode282Supplying of 2 feet LED PVC square batten with high quality diffuser with ife of 25000 burninng hours & 70% lumen maintance with CRI.80. power input :220-240V @ 50 hz & power factor ..9 along with CE approved drivers. 5 years warranty LED light fitting 1x4' -20/22w Complete specification as per engineer in charge.Each814.2814.2256.0FalseNoneNoneFalseNoneFalse208435.20
3089683106226Nonecode283Supplying of recess mounting non integrated type LED down light 15-18W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clA, LED of Power/COB with CCT 6500 degree K, CRI. 70%. efficacy .100 lumen per W, 120degree beam spread, life. 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PF . 0.95, power loss should. 5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.Complete specification as per engineer in charge.Each1971.781971.7898.0FalseNoneNoneFalseNoneFalse193234.440
3089684106226Nonecode284Fixing all types and all capacities of fluorescent / fales ceiling /spot light /CFL / LED fittings indoor on the wall /ceiling / refters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps .Complete specification as per engineer in charge.Each143.96143.96347.0FalseNoneNoneFalseNoneFalse49954.120
3089685106226Nonecode285Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double bail bearing system. 48" Sweep (1200mm) Complete specification as per engineer in charge.Each3521.123521.1273.0FalseNoneNoneFalseNoneFalse257041.760
3089686106226Nonecode286Fixing a ceiling / wall mounting fan of all capacities and all types to the existing 's' hook with fan regulator to the existing board together with supplying and fixiting 5amps . Ceiling rose, necessary length of 23/0.0076 inch PVC insulated twin twisted copper wire and wiring .Complete specification as per engineer in charge.Each201.78201.7875.0FalseNoneNoneFalseNoneFalse15133.50
3089687106226Nonecode287Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum.(Tipper 14 m3) Complete specification as per engineer in charge.Cum111.63111.63841.679FalseNoneNoneFalseNoneFalse93956.626770
3089688106226Nonecode288Cost of Haulage Excluding Loading and Unloading Taking output 25 t load and lead 10 km = 250 t.km Complete specification as per engineer in charge.T.Km174.45174.45841.679FalseNoneNoneFalseNoneFalse146830.901550
3089689106226Nonecode289Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking to the appropriate disposal area as per direction of Engineerin- charge.. Of area 3 m² and below(V2) Complete specification as per engineer in charge.Sqm311.52311.5282.44FalseNoneNoneFalseNoneFalse25681.70880
3089690106226Nonecode290Dismantling tiled roofing with battens, boarding etc. complete including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.Sqm185.62185.62196.35FalseNoneNoneFalseNoneFalse36446.4870
3089691106226Nonecode291Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground to the appropriate disposal area as per direction of Engineer-in-charge.Each48.0348.031355.801FalseNoneNoneFalseNoneFalse65119.122030
3089692106226Nonecode292Providing and fixing factory made Kitchen Cabinet Shutter/Partition 20mm nominal thickness of approved shade, quality and make, madefrom rigid foam sheets (Single extruded) having density 600 kg/m3 andlaminated on both side by laminate Sheet/PVC foil lamination. Theexposed edges shall be sealed with PVC edge beading of same shadeand colour. The shutter shall be fire retardent having necessary screwholding capacity. Shutter shall be fixed to frame using approved hingeswith necessary stainless steel screws, all complete as per direction ofEngineer-in-chargeKg5381.515381.51177.66FalseNoneNoneFalseNoneFalse956079.06660
3089693106226Nonecode293Supplying, installing, testing and commissioning of Diesel Generator set with following specifications. Power rating as per standard reference condition as per-BS 5514/ISO 3046/ ISO 8528 & IS 1002/ISO 3046 Generator set specifications. Engine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade), Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation Alternator: Alternator is suitable for operation at 1500 RPM, 415 V, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming to IS/IEC 60034-1. The Alternator is brush less type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have 1.0% Voltage regulation (max) in static conditions- IP: 23 protections with insulation class F&H Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads.Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lA for 'Load On' and 'Set Running', Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight.Complete specification as per engineer in charge.Each756463.78756463.781.0FalseNoneNoneFalseNoneFalse756463.780
3089694106226Nonecode294Fabricating, supplying and erection of 8ms long hot dip Galvanized Conical hot dip Pole with BSEN 10025 grade S355JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for 8m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom 155 mm , top 75 mm with 3 mm thick, suitable base plate and 4Nos of.........long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc.,(excluding foundation) as per drawing appended. 8 m - Top 75 mm and Bottom 155 mm diaComplete specification as per engineer in charge.Each21122.021122.092.0FalseNoneNoneFalseNoneFalse1943224.00
3089695106226Nonecode295Supplying, and fixing of Hot dip Galvanized M.S.Bracket suitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete.- Single Arm Bracket with 2000 mm Standard 40/50 mm diaComplete specification as per engineer in charge.Each3068.03068.092.0FalseNoneNoneFalseNoneFalse282256.00
3089696106226Nonecode296Supplying, and fixing of Hot dip Galvanized M.S.Bracket suitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete.- Single Arm Bracket with 1000 mm Standard 40/50 mm dia Complete specification as per engineer in charge.Each2006.02006.092.0FalseNoneNoneFalseNoneFalse184552.00
3089697106226Nonecode297Supplying, and fixing of Hot dip Galvanized M.S.Bracket suitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete.- Double Arm Bracket with 1500 mm Standard 40/50 mm diaComplete specification as per engineer in charge.Each3894.03894.092.0FalseNoneNoneFalseNoneFalse358248.00
3089698106226Nonecode298Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT . 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire . IK08. Power Factor .0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 150 W System Power consumption. LED Efficiency.1301m/w, nominal CRI .75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned - LED Streetlight 150 W Complete specification as per engineer in charge.No17351.917351.992.0FalseNoneNoneFalseNoneFalse1596374.80
3089699106226Nonecode299Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT . 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire . IK08. Power Factor .0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 150 W System Power consumption. LED Efficiency.1301m/w, nominal CRI .75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned - LED Streetlight 40W Complete specification as per engineer in charge.No4748.324748.3292.0FalseNoneNoneFalseNoneFalse436845.440
3089700106226Nonecode300Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires.Complete specification as per engineer in charge.Each191.16191.1692.0FalseNoneNoneFalseNoneFalse17586.720
3089701106226Nonecode301Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS- 694:2010 - 3C x 2.5 mm2 Complete specification as per engineer in charge.Mtr133.34133.34920.0FalseNoneNoneFalseNoneFalse122672.80
3089702106226Nonecode302Aerial Bunched Cable (ABC) 1.1 kV, LT Aerial Bunched Cable, XLPE insulation confirming to IS-14255: 1995 - 3x25 + 1x25 + 1x16 Sqmm Street light (Insulated Messenger cum Neutral) Complete specification as per engineer in charge.Km194500.58194500.583.31FalseNoneNoneFalseNoneFalse643796.91980
3089703106226Nonecode303LABOUR for Aerial Bunched Conductor & Accessories - Stringing of 1.1 kV grade Aerial Bunched 3 Core cable of XLPE insulation of size (3x95) (Phase Conductor) + (1x70) (Insulated Messenger Neutral) + (1x25) (Street Light Control)Complete specification as per engineer in charge.Km41022.741022.73.31FalseNoneNoneFalseNoneFalse135785.1370
3089704106226Nonecode304KV 1.1, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 25 Sqmm, 3.5 Core, (12 GI Strips - 4 x 0.8 mm)Complete specification as per engineer in charge.Km164667.82164667.820.31FalseNoneNoneFalseNoneFalse51047.02420
3089705106226Nonecode305Labour Charge for Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 to 25 Sqmm Complete specification as per engineer in charge.Km24645.4824645.480.31FalseNoneNoneFalseNoneFalse7640.09880
3089706106226Nonecode306Transporting Cable from Store to work spot including loading and unloading (including Crane and other equipment charges if any) LT Cable 2.5 to 25 Sqmm (Single/3.5/4 Core) Complete specification as per engineer in charge.Km1400.661400.660.31FalseNoneNoneFalseNoneFalse434.20460
3089707106226Nonecode307Laying of UG Cables by Trenchless Technology (HDD) by adopting Horizontal Boring & Drawing of cable including preparation at siteComplete specification as per engineer in charge.Rmtr1119.821119.82250.0FalseNoneNoneFalseNoneFalse279955.00
3089708106226Nonecode308Suspension Clamp suitable for insulated Messsenger wire of size 25 to 95 Sqmm Complete specification as per engineer in charge.No418.9418.992.0FalseNoneNoneFalseNoneFalse38538.80
3089709106226Nonecode309Labour Charge for Erection of Suspension Clamp - 25 to 95 Sqmm insulated messenger with bracket Complete specification as per engineer in charge.No226.56226.5692.0FalseNoneNoneFalseNoneFalse20843.520
3089710106226Nonecode310Universal Hook and Bolt & Nut Complete specification as per engineer in charge.No392.94392.9492.0FalseNoneNoneFalseNoneFalse36150.480
3089711106226Nonecode311Labour Charge for Fixing of Universal Hook Complete specification as per engineer in charge.No226.56226.5692.0FalseNoneNoneFalseNoneFalse20843.520
3089712106226Nonecode312Piercing Connector Suitable for 16 Sqmm - 95 Sqmm AB Cable - Street Light Connection Complete specification as per engineer in charge.No219.48219.4892.0FalseNoneNoneFalseNoneFalse20192.160
3089713106226Nonecode313Labour Charge for Installation of Insulation piercing connector for Main to Service Line Main : 16- 95 Sqmm, Tap: 4-35 Sqmm (P2X95) Complete specification as per engineer in charge.No151.04151.0492.0FalseNoneNoneFalseNoneFalse13895.680
3089714106226Nonecode314GI Pipe B - Class as per IS-1239 GI Pipe - 20 mm Dia Complete specification as per engineer in charge.No174.64174.6492.0FalseNoneNoneFalseNoneFalse16066.880
3089715106226Nonecode315GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg Complete specification as per engineer in charge.No876.74876.7492.0FalseNoneNoneFalseNoneFalse80660.080
3089716106226Nonecode316Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each Complete specification as per engineer in charge.No797.68797.6892.0FalseNoneNoneFalseNoneFalse73386.560
3089717106226Nonecode317Good Quality Salt for grounding purposes packed in 50 Kg gunny bag Complete specification as per engineer in charge.No365.8365.892.0FalseNoneNoneFalseNoneFalse33653.60
3089718106226Nonecode318Rod Earthing: Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified Complete specification as per engineer in charge.No2562.962562.9692.0FalseNoneNoneFalseNoneFalse235792.320
3089719106226Nonecode319Bentonite clay slurry for earthing in 50 Kg Bag Complete specification as per engineer in charge.Bag434.24434.2492.0FalseNoneNoneFalseNoneFalse39950.080
3089720106226Nonecode320Fabricating supplying and mounting MS box made out 14 SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc.,Complete specification as per engineer in charge.Sq CM0.590.59224640.0FalseNoneNoneFalseNoneFalse132537.60
3089721106226Nonecode321Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat 40 x 40 x 6 mm with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.Complete specification as per engineer in charge.Mtr359.9359.948.0FalseNoneNoneFalseNoneFalse17275.20
3089722106226Nonecode322Supplying and fixing Microprocessor Based Astronomical timer Switch with using necessary bolts, nuts and washers.Complete specification as per engineer in charge.Each5714.745714.7412.0FalseNoneNoneFalseNoneFalse68576.880
3089723106226Nonecode323Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 100 A Complete specification as per engineer in charge.Each815.38815.3818.0FalseNoneNoneFalseNoneFalse14676.840
3089724106226Nonecode324Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. - 100 to 125 A Complete specification as per engineer in charge.Each10649.510649.512.0FalseNoneNoneFalseNoneFalse127794.00
3089725106226Nonecode325Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. - 6-32 A SP Complete specification as per engineer in charge.Each489.7489.712.0FalseNoneNoneFalseNoneFalse5876.40
3089726106226Nonecode326Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. - 50-63 A TPN Complete specification as per engineer in charge.Each3643.843643.8412.0FalseNoneNoneFalseNoneFalse43726.080
3089727106226Nonecode327Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. THREE Pole 100 A 25 kA Complete specification as per engineer in charge.Each7181.487181.4812.0FalseNoneNoneFalseNoneFalse86177.760
3089728106226Nonecode328Epoxy Terminating Kit (Pothead) suitable for 1.1 kV, LTUG Cable Up to 4C x 50 Sqmm Complete specification as per engineer in charge.Set382.32382.326.0FalseNoneNoneFalseNoneFalse2293.920
3089729106226Nonecode329Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990. 3C x 10 mm2 Complete specification as per engineer in charge.Each289.1289.195.0FalseNoneNoneFalseNoneFalse27464.50
3089730106226Nonecode330Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . Icu=100% lcs). In 4P MCCB, all Poles should have protection for hort-Cicrcuit/Over Load. For Microprocessor MCCBS Facility forsegregating Priority and Non-Priority loads must be available in the CCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 160 A 25 kA Complete specification as per engineer in charge.Each15867.4615867.462.0FalseNoneNoneFalseNoneFalse31734.920
3089731106226Nonecode331Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 6089 8. 5.18.4 6-32 A DP Complete specification as per engineer in charge.Each872.02872.0257.0FalseNoneNoneFalseNoneFalse49705.140
3089732106226Nonecode332Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 6089. 50-63 A TPN Complete specification as per engineer in charge.Each3643.843643.8410.0FalseNoneNoneFalseNoneFalse36438.40
3089733106226Nonecode3335.19 Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 12 Way SP & N Complete specification as per engineer in charge.Each2748.222748.223.0FalseNoneNoneFalseNoneFalse8244.660
3089734106226Nonecode334Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. Complete specification as per engineer in charge.Each10920.910920.95.0FalseNoneNoneFalseNoneFalse54604.50
3089735106226Nonecode335Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 6089 8. 5.18.4 6-32 A DP Complete specification as per engineer in charge.Each489.7489.715.0FalseNoneNoneFalseNoneFalse7345.50
3089736106226Nonecode336Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 200 x 90 x 65 mm Complete specification as per engineer in charge.Each211.22211.2250.0FalseNoneNoneFalseNoneFalse10561.00
3089737106226Nonecode337Supplying of recess mounting non integrated type LED down light...... W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power/COB with CCT 6500 degree K, CRI. 70%. efficacy .100 lumen per W, 120degree beam spread, life. 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PF . 0.95, power loss should. 5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.10-12W Complete specification as per engineer in charge.Each1497.421497.4290.0FalseNoneNoneFalseNoneFalse134767.80
3089738106226Nonecode338Fixing all types and all capacities of 1'x4' / 2'x2' LED Light fittings indoor on the wall / ceiling / rafters / girders with necessary supporting frame, using 2310.0076" twin twisted PVC insulated wires,required Nos of round blocks and clamps.Complete specification as per engineer in charge.Each578.2578.2341.0FalseNoneNoneFalseNoneFalse197166.20
3089739106226Nonecode339Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 1 4 Way.Complete specification as per engineer in charge.Each12188.2212188.2214.0FalseNoneNoneFalseNoneFalse170635.080
3089740106226Nonecode340Supplying capacitor type ceiling fan complete with down rod blades,shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200 mm) Regular model Complete specification as per engineer in charge.Each3521.123521.1225.0FalseNoneNoneFalseNoneFalse88028.00
3089741106226Nonecode341Supplying wall mounting fan suitable to operate at single- phase 230v AC. supply. 300 mm Sweep Complete specification as per engineer in charge.Each2940.562940.5620.0FalseNoneNoneFalseNoneFalse58811.20
3089742106226Nonecode342Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.32A DP Switch Complete specification as per engineer in charge.Each278.48278.4810.0FalseNoneNoneFalseNoneFalse2784.80
3089743106226Nonecode343LED Down light Supply of round/square recess/surface mounted rolling type LED Down light with W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI . 80. Power Input: 220-240V @50/60Hz & Power factor .0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition, LED square or round down light 10-12W Complete specification as per engineer in charge.Each1044.31044.388.0FalseNoneNoneFalseNoneFalse91898.40
3089744106226Nonecode344LED Down light Supply of round/square recess/surface mounted rolling type LED Down light with W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI . 80. Power Input: 220-240V @50/60Hz & Power factor .0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition, LED square or round down light 15-18W Complete specification as per engineer in charge.Each1562.321562.3253.0FalseNoneNoneFalseNoneFalse82802.960
3089745106226Nonecode345Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/ clear glass material, delivering superior light outputRated life Burning Hrs 50000 hr@ Lumen Maintenance of 70%, CCT . 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire . IK08. Power Factor.0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/1 EC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB LED Efficiency.1301m/w, nominal CRI .75. Luminaire manufacturer should have in- house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Post Top Lantern with 35/40w Complete specification as per engineer in charge.Each11353.9611353.966.0FalseNoneNoneFalseNoneFalse68123.760
3089746106226Nonecode346Fabricating, supplying and erecting Swaged tubular Pole of height ...m having three sections, and providing two coats of red oxide paint and finished with two coats of enamelled paint of approved quality and colour and M.S. base plate of suitable size welded at the bottom of the Pole(as per IS) and 40 mm dia GI/flexible PVC pipe of 1m length fitted to the heavy gauge polycarbonate control box including 5 Way connector of size 167 x 125 x 82 mm for 7.5M Pole/ 200 x 160 x 98 mm for remaining length of Pole with front opening cover, with locking arrangements and suitable capacity MCB/DP switch, The Pole shall be erected in cement concrete work (1:2:4) including excavation and refilling of planting depth of the Pole to the ground level and the coping CC shall be upto 0.6m above ground level as per IS2713-7. Erection of heavy duty Pole on Footpath/median 4.1.1 9m (5m Hb,165.1 mm dia 4.85 mm thick x 2m Hm, 139.7 mm dia 4.50 mm thick x 2m Ht,114.3 mm dia 3.65 mm thick) as per IS 410 SP 32 Complete specification as per engineer in charge.Each18290.018290.040.0FalseNoneNoneFalseNoneFalse731600.00
3089747106226Nonecode347Supplying and Fixing of........mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires. Using 32mm dia G.I.Pipe Complete specification as per engineer in chargeEach1233.11233.1100.0FalseNoneNoneFalseNoneFalse123310.00
3089748106226Nonecode348Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT . 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire . IK08. Power Factor .0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency.1301m/w, nominal CRI .75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.11.8.4 LED Streetlight 90 W Complete specification as per engineer in chargeEach10454.810454.8201.0FalseNoneNoneFalseNoneFalse2101414.80
3089749106226Nonecode349Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT . 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire . IK08. Power Factor .0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency.1301m/w, nominal CRI .75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.11.8.4 LED Streetlight 120 W Complete specification as per engineer in chargeEach11870.811870.8150.0FalseNoneNoneFalseNoneFalse1780620.00
3089750106226Nonecode350Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT . 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire . IK08. Power Factor .0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ....... W System Power consumption. LED Efficiency. 1301m/w, nominal CRI .75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.11.9.4 LED Floodlight 150W Complete specification as per engineer in chargeEach14738.214738.272.0FalseNoneNoneFalseNoneFalse1061150.40
3089751106226Nonecode351Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. Complete specification as per engineer in chargeEach191.16191.16550.0FalseNoneNoneFalseNoneFalse105138.00
3089752106226Nonecode352Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4" dia telescopic M. S. pipe, with 2" dia1.5m long M.S.Bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 ms. M. S. tubular pole, with necessary two coats of painting, with all other accessories. 13.4.1 Single bracket 1.5 m. Length. Complete specification as per engineer in charge.Each1723.981723.98350.0FalseNoneNoneFalseNoneFalse603393.00
3089753106226Nonecode353Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.5.41.2 50 x 50 x 6 mm. Complete specification as per engineer in chargeMtr466.1466.1300.0FalseNoneNoneFalseNoneFalse139830.00
3089754106226Nonecode354Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.5.44.2 300 mm x 450 mm x 214 mm. Complete specification as per engineer in chargeEach7272.347272.34100.0FalseNoneNoneFalseNoneFalse727234.00
3089755106226Nonecode355Supplying and fixing hylum plastic sheet 3mm thick with necessary nitches for fixing switches, regulators etc., and fixing on existing wood or metal box using N. F. screws. Complete specification as per engineer in chargeSq CM0.420.4270000.0FalseNoneNoneFalseNoneFalse29400.00
3089756106226Nonecode356Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 5.14.8 120A. Complete specification as per engineer in chargeEach26643.2226643.2280.0FalseNoneNoneFalseNoneFalse2131457.60
3089757106226Nonecode357Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 5.18.2 40 A SP. Complete specification as per engineer in chargeEach935.74935.7480.0FalseNoneNoneFalseNoneFalse74859.20
3089758106226Nonecode358Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 5.18.6 50-63 A DP. Complete specification as per engineer in chargeEach1300.361300.3680.0FalseNoneNoneFalseNoneFalse104028.80
3089759106226Nonecode359Supplying, erecting, testing & commissioning of OFF- LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with all accessories complete and Excluding batteries and wiring complete. 9.2.1 1 kVA OFF LINE UPS. Complete specification as per engineer in chargeEach17802.6617802.6645.0FalseNoneNoneFalseNoneFalse801119.70
3089760106226Nonecode360GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg Complete specification as per engineer in chargeNos876.74876.7445.0FalseNoneNoneFalseNoneFalse39453.30
3089761106226Nonecode361Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each. Complete specification as per engineer in chargeNos797.68797.6845.0FalseNoneNoneFalseNoneFalse35895.60
3089762106226Nonecode362Good Quality Salt for grounding purposes packed in 50 Kg gunny bagNos365.8365.845.0FalseNoneNoneFalseNoneFalse16461.00
3089763106226Nonecode3631.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 10 Sqmm, 2 Core, (9 GI Strips - 4 x 0.8 mm).Complete specification as per engineer in chargeKm93493.7693493.761.0FalseNoneNoneFalseNoneFalse93493.760
3089764106226Nonecode364Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cm. Thickness including depositing of the surplus earth with a lead of 200 Mtr. Complete specification as per engineer in chargeCum68.4468.44900.0FalseNoneNoneFalseNoneFalse61596.00
3089765106226Nonecode365Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.5.41.2 50 x 50 x 6 mmMtr466.1466.1250.0FalseNoneNoneFalseNoneFalse116525.00
3089766106226Nonecode366Supplying and fixing hylum plastic sheet 3mm thick with necessary nitches for fixing switches, regulators etc., and fixing on existing wood or metal box using N. F. screws. Complete specification as per engineer in chargeSq CM0.420.4260000.0FalseNoneNoneFalseNoneFalse25200.00
3089767106226Nonecode367Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.63 A. Complete specification as per engineer in chargeEach473.18473.1845.0FalseNoneNoneFalseNoneFalse21293.10
3089768106226Nonecode36811.1 Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete. Complete specification as per engineer in chargeMtr575.84575.8445.0FalseNoneNoneFalseNoneFalse25912.80
3089769106226Nonecode369Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to20A single phase Class-1 Accuracy with Temper Proof EnergyMeter.Each1628.41628.445.0FalseNoneNoneFalseNoneFalse73278.00
3089770106226Nonecode370Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.5.44.2 300 mm x 450 mm x 214 mm. Complete specification as per engineer in chargeEach7272.347272.3445.0FalseNoneNoneFalseNoneFalse327255.30
3089771106226Nonecode371Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work - In all kinds of soils Depth upto 3 m. Complete specification as per engineer in chargeCum132.39132.3992.0FalseNoneNoneFalseNoneFalse12179.880
3089772106226Nonecode372Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates. Complete specification as per engineer in chargeCum7773.737773.732.576FalseNoneNoneFalseNoneFalse20025.128480
3089773106226Nonecode373Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Complete specification as per engineer in chargeCum8568.568568.5662.192FalseNoneNoneFalseNoneFalse532895.883520
3089774106226Nonecode374Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately). Complete specification as per engineer in chargeTonne116115.18116115.182.38FalseNoneNoneFalseNoneFalse276354.12840
3089775106226Nonecode375Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm419.26419.26151.8FalseNoneNoneFalseNoneFalse63643.6680
3089776106226Nonecode376Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility - 300 mm x 600 mm x 170 mm. Complete specification as per engineer in chargeEach8103.068103.066.0FalseNoneNoneFalseNoneFalse48618.360
3089777106226Nonecode377Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete- 100 A 4 x 30 x 6 mm Aluminium Strips. Complete specification as per engineer in chargem2908.72908.77.5FalseNoneNoneFalseNoneFalse21815.250
3089778106226Nonecode378Supplying of hiK vision 8 channel NVR (NVR Default without HDD). Complete specification as per engineer in chargeEach19917.2219917.2297.0FalseNoneNoneFalseNoneFalse1931970.340
3089779106226Nonecode379Supplying Of 1.3 mega pixels hikvision/reputed CCTV Camera. Complete specification as per engineer in chargeEach15812.015812.097.0FalseNoneNoneFalseNoneFalse1533764.00
3089780106226Nonecode380Supplying of hiK vision PTZ Camera with pole mount and power supply. Complete specification as per engineer in chargeEach76700.076700.010.0FalseNoneNoneFalseNoneFalse767000.00
3089781106226Nonecode381Supplying of 2 TB Hard disk seagate. Complete specification as per engineer in chargeEach12449.012449.0107.0FalseNoneNoneFalseNoneFalse1332043.00
3089782106226Nonecode382Supplying of 4+4 POE Switch TP Link. Complete specification as per engineer in chargeEach8465.328465.32107.0FalseNoneNoneFalseNoneFalse905789.240
3089783106226Nonecode383Supplying of 4pin spike pin Cona /reputed. Complete specification as per engineer in chargeEach1351.11351.1107.0FalseNoneNoneFalseNoneFalse144567.70
3089784106226Nonecode384Supplying of outdoor supportable CAD 6 CADS Cable. Complete specification as per engineer in chargeEach82.682.61750.0FalseNoneNoneFalseNoneFalse144550.00
3089785106226Nonecode385Supplying of pole for PTZ erection with civil work. Complete specification as per engineer in chargeEach20266.520266.510.0FalseNoneNoneFalseNoneFalse202665.00
3089786106226Nonecode386Supplying of Hardware items and fixing charges. Complete specification as per engineer in chargeEach1711.01711.0107.0FalseNoneNoneFalseNoneFalse183077.00
3089787106226Nonecode387Supplying of LED 42'' TV Make SAMSUNG/LG/Philips/Videocon. Complete specification as per engineer in chargeEach83723.3683723.368.0FalseNoneNoneFalseNoneFalse669786.880
3089788106226Nonecode388Installation charges for cameras and NVR. Complete specification as per engineer in chargeEach4779.04779.0107.0FalseNoneNoneFalseNoneFalse511353.00
3089789106226Nonecode389IP Configuration. Complete specification as per engineer in chargeEach3811.43811.4107.0FalseNoneNoneFalseNoneFalse407819.80
3089790106226Nonecode390outdoor supportable CAD 6 CADS Cabling Laying charges. Complete specification as per engineer in chargeEach51.9251.921750.0FalseNoneNoneFalseNoneFalse90860.00
3089791106226Nonecode391Supplying,erecting,testing and commissioning of OFF-Line UPS System Suitable for operation on 230V, 50Hz, A/C Supply, with l Accesssories complete and excluding batteris and wiring complete. Complete specification as per engineer in chargeEach17802.6617802.66107.0FalseNoneNoneFalseNoneFalse1904884.620
3089792106226Nonecode392Fabricating suplying and mounting MS Box made out of 16 SWG Suitable for floor/Wall mounting, fully wether proof with provision for better heat dissipation, provided ith hinged front cover, equipped with provion with tamper proof locking arrngements, with suitble size clamps with neccessary cable entry pipewith gland and box should b inished with 7 tanks tretement with powder coated paint nd finally finished with approves colour etc. complete. Complete specification as per engineer in chargeSq CM0.510.51919500.0FalseNoneNoneFalseNoneFalse468945.00
3089793106226Nonecode393Supplying and fixing miniture circuit breker on exsting MCB Distributors boards using necessary fixing materials and "C" Type Curve, indicator ON/OFF, energy cross-3 with short circuite breakng capacity of 10K and Complete wiring as rquird confirming to IEC 60898. 6-32 A DP. Complete specification as per engineer in chargeEach872.02872.02107.0FalseNoneNoneFalseNoneFalse93306.140
3089794106226Nonecode394Wiring for Lighting/power ciruit using one of PV insulated 1100v Grade, standard alluminium wire single cire in opn or Concealed system of Wiring. 2.5 Sqmm. Complete specification as per engineer in chargeRmtr49.5649.562867.5FalseNoneNoneFalseNoneFalse142113.30
3089795106226Nonecode395Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 200 x 200 x 65 mm. Complete specification as per engineer in chargeEach410.64410.6440.0FalseNoneNoneFalseNoneFalse16425.60
3089796106226Nonecode396Supplying and fixing PVC/metal conduit Deep junction box 32 mm deep Junction box. Complete specification as per engineer in chargeEach71.9871.9840.0FalseNoneNoneFalseNoneFalse2879.20
3089797106226Nonecode397SUPPLYING AND FIXING OF TREADMILL COMMERCIAL AC Motor 4HP / 7HP with mitsubishi 19 japan inverter drive speed 1-20KM/H incline 0-20% automatic, preset programs P1-P8, running Approved Kamm, Automatic Lubrication System, max user w 200Kgs Gross Wt 287 Kgs Rate. Complete specification as per engineer in chargeNos409460.0409460.02.0FalseNoneNoneFalseNoneFalse818920.00
3089798106226Nonecode398Supplying and fixing of elliptical cross trainerself generator system tension.motorized adjustable workout tension or 16 fitness levels, Monitor programable and functional computerr monitor with large window LCD Display Console delux computer console with book racke. Complete specification as per engineer in chargeNos252225.0252225.02.0FalseNoneNoneFalseNoneFalse504450.00
3089799106226Nonecode399SUPPLYING AND FIXING OF ROWER -CONCEPT2 Monitor PM 5, Overall length 96 in,width 24 in,seat height 14 in, monorail length 54in chain or cord nickel plated steel chain partialy enclosed power generation. Complete specification as per engineer in chargeNos200718.0200718.02.0FalseNoneNoneFalseNoneFalse401436.00
3089800106226Nonecode400SUPPLYING AND FIXING OF PECK FLYERS N REAR DELT Dimension : 1410x1380x1930 net 22 weight :215 kg stack wieght 92 kg suare tube 50*100,thickness 2.5mm square tube 50*100 thickness 2.5 mm high strength steel oval tube precision welds intelligent. Complete specification as per engineer in chargeNos347480.5347480.52.0FalseNoneNoneFalseNoneFalse694961.00
3089801106226Nonecode401SUPPLY AND FIXING OF SETED LEG PRESS. Dimension 1830X1170X1580 net weight 289 kgs Stack Weight 92 kgs Square tube 50x100 thickness 2.5mm High Strength Steel Oval tube Precision welds Intelligents ergonomic desgin features 5/16" diameter weight selector pin magnetically locks in placards in visible positions hard grips secured in place with aluminum collars comprised of an extruded rubber compound i.e; non-absorbing and wear resistant. Two round powder coated. Nylon pulley, cable 6mm.Complete specification as per engineer in chargeNos353144.5353144.52.0FalseNoneNoneFalseNoneFalse706289.00
3089802106226Nonecode402SUPPLY AND FIXING SEATED LEG EXTENSION /LEG CURL Dimension: 1420*1600*1280 net wieght :240 kg stack weight 92 kg square tube 50*100,thickness 2.5mm high strength steel tube 50*100 thickness 2.5mm wieght selector pin magnetically locks in place and inludes lanyard to. Complete specification as per engineer in chargeNos348277.0348277.02.0FalseNoneNoneFalseNoneFalse696554.00
3089803106226Nonecode403SUPPLY AND FIXING ASSISTED CHIN UO Dimension 1820*1080 2230 net weight 280kg 25 stack wieght 92 kg square tube 50*100 50*100, thickness 2.5mm high strength steel tube 50*100 thickness 2.5mm wieght selector pin magnetically locks in place and inludes lanyard. Complete specification as per engineer in chargeNos344855.0344855.02.0FalseNoneNoneFalseNoneFalse689710.00
3089804106226Nonecode404SUPPLY AND FITTING OF ABDOMINAL CRUNCH, Dimension: 1420*1600*1280 net wieght :240 kg stack weight 92 kg square tube 50*100, thickness 2.5mm high strength steel tube 50*100 thickness 2.5mm wieght selector pin magnetically locks in place and inludes lanyard. Complete specification as per engineer in chargeNos352112.0352112.02.0FalseNoneNoneFalseNoneFalse704224.00
3089805106226Nonecode405SUPPLY AND FIXING OF SMITH MACHINE Dimension 1380x2250x229 Net Weight 161 kgs Square tube 50x100 thickness 2.5mm High Strength Steel Oval tube Precision welds Intelligents ergonomic desgin features Two round powder coated. Fixed as per Engineer in Charges of Work. Complete specification as per engineer in chargeNos369133.5369133.52.0FalseNoneNoneFalseNoneFalse738267.00
3089806106226Nonecode406SUPPLY AND FIXING OF MULTIFUNCTIONAL BENCH (FLAT INCLINE Dimension 1350X610X1230 Net Weight 36 kgs Square tube 50x100 thickness 2.5mm High Strength Steel Oval tube Precision welds Intelligents ergonomic desgin features Two round powder coated. Fixed as per Engineer in Charges of Work. Complete specification as per engineer in chargeNos96760.096760.01.0FalseNoneNoneFalseNoneFalse96760.00
3089807106226Nonecode407SUPPLY AND FIXING OLYMPIC INCLINE BENCH PRESS, Dimension 1750 1630*1460.net weight 104kg square tube 50*100 thickness 2.5mm high stength steel oval tube precision welds. Complete specification as per engineer in chargeNos111038.0111038.01.0FalseNoneNoneFalseNoneFalse111038.00
3089808106226Nonecode408SUPPLY AND FIXING OF DUMBBELL RACK (3 TIER) Dimension 1400X680X1000mm Net Weight 100 kgs Square tube 50x100 thickness 2 5mm High Strength Steel Oval tube Precision welds Intelligents ergonomic desgin features Two round powder coated. Fixed as per Engineer in Charges of Work. Complete specification as per engineer in chargeNos56994.056994.01.0FalseNoneNoneFalseNoneFalse56994.00
3089809106226Nonecode409SUPPLYING OF CHALLENING BARS. 7X2, 6X2, 5X2, EZ 4X2 NO. Full solid steel with 50 Dia plate holder sleeve. Complete specification as per engineer in chargeNos14868.014868.02.0FalseNoneNoneFalseNoneFalse29736.00
3089810106226Nonecode410SUPPLYING OF DUMBBELL Rubber material and steel handle with knurling for grip. Complete specification as per engineer in chargePer Kg413.0413.0275.0FalseNoneNoneFalseNoneFalse113575.00
3089811106226Nonecode411SUPPLYING AND FIXING OF BICEPS EXERSISE Dimension: 1350*1250*1420 NET WIEGHT 190kg stock wieght 72 kg square tube 50*100, thickness 2.5mm, high strength steel oval tube precision welds intelligent economic design future 5/16 dia meter wieght selector pin magnecticalls logs in place features two rounds powder coated fixed as per engineering incharge. Complete specification as per engineer in chargeNos352466.0352466.01.0FalseNoneNoneFalseNoneFalse352466.00
3089812106226Nonecode412SUPPLY AND FIXING OF CALF MACHINE Dimension 1500*550*900 net wieght 45kg square tube 50*100 thick 2.5mm high strenth steel oval tube precision welds inteligent economin design features two rounds powder coated fixed as per engineering incharge.Complete specification as per engineer in chargeNos96878.096878.01.0FalseNoneNoneFalseNoneFalse96878.00
3089813106226Nonecode413Design, supplying, erecting testing and commissioning of - Passenger/ Bed-cum-passenger hospital lift with speed of 1mtr per second, variable voltage variable frequency drive, with or without machine room for the available well size, operating at 415 V 3 phase 50 cycles AC supply,powder coated / Stainless Steel car entrance doors enclosures with suitable colour vinyl flooring, LED car illumination, emergency light, intercom and fan as desired by the user, central opening / side opening door with or without attendant operation, 7 segment display buttons,call register indicator, fireman drive, SS handrails inside car, full length infrared curtain in car door, automatic rescue device with batteries,voice announcing in regional/ international languages, Braille buttons with one year warranty and maintenance with necessary scaffolding and minor civil works like fixing of guide rail, counter weight etc.,The total product and services shall adhere to IS 14665/2016 ( with latest amendments) part/section 1 to 5 with regards to general guidelines of fire safety rated doors, MRLL beams, pressure switch, manual change over for doors during emergency, ARD of 10 times with sufficient battery back up and standard dimensions of chair car and door openings for all sizes and capacities of lifts including fitness certificate and duly observing all other safety norms prescribed and adhere to CPWD specifications, PCB Norms, National Electricity Code (NEC), NBC-2016, IEC and Karnataka State Lifts, Escalators and Passengers Conveyers Act 2012 and Rules 2014. The Supplier shall be registered in Government Electrical Inspectorate in the State of Karnataka. A. With Machine Room-PC Finish-Capacity 6 Passengers 3 stops. Complete specification as per engineer in chargeEach1536900.871536900.873.0FalseNoneNoneFalseNoneFalse4610702.610
3089814106226Nonecode414Executive office revolving Chair with Head rest and arms, Complete specification as per engineer in chargeNos16520.016520.02.0FalseNoneNoneFalseNoneFalse33040.00
3089815106226Nonecode415steel almirah with shelves and locker 6.6 Feet, 18/20Gauage, Size78"x36"x19. Complete specification as per engineer in chargeNos17110.017110.02.0FalseNoneNoneFalseNoneFalse34220.00
3089816106226Nonecode416Supply of Hikvision 8 channel NVR/DVR DS 7608NI-E1 (NVR Dealt without HDD). Complete specification as per engineer in chargeEach19917.2219917.221.0FalseNoneNoneFalseNoneFalse19917.220
3089817106226Nonecode417Supply of 1.3 Mega Picsels Hikvision CC TV Camera DS2CD20F-1. Complete specification as per engineer in chargeEach15812.015812.024.0FalseNoneNoneFalseNoneFalse379488.00
3089818106226Nonecode418SUPPLY AND FIXING SEATED LEG EXTENSION /LEG CURL Dimension: 1420*1600*1280 net wieght :240 kg stack weight 92 kg square tube 50*100,thickness 2.5mm high strength steel tube 50*100 thickness 2.5mm wieght selector pin magnetically locks in place and inludes lanyard to. Complete specification as per engineer in chargeNos12449.012449.02.0FalseNoneNoneFalseNoneFalse24898.00
3089819106226Nonecode419Supply of 4+4 Pole switch TP link. Complete specification as per engineer in chargeNos8465.328465.3232.0FalseNoneNoneFalseNoneFalse270890.240
3089820106226Nonecode420Supply of 4 Pin Spike Pin Cona / Reputed.Complete specification as per engineer in chargeNos1351.11351.12.0FalseNoneNoneFalseNoneFalse2702.20
3089821106226Nonecode421Supplying of 42" LED TV Make SAMSUNG/LG/PHILLIPS/VIDEOCON. Complete specification as per engineer in chargeNos83723.3683723.362.0FalseNoneNoneFalseNoneFalse167446.720
3089822106226Nonecode422Providing and laying Outdoor supportable CAD 6/ CAD5 Cables. Complete specification as per engineer in chargeMtr51.9251.926.0FalseNoneNoneFalseNoneFalse311.520
3089823106226Nonecode423SWS 4000A HD equipment. Complete specification as per engineer in chargeNos1044300.01044300.017.0FalseNoneNoneFalseNoneFalse17753100.00
3089824106226Nonecode4241 stage RO PLANT 500 LPH. Complete specification as per engineer in chargeNos389872.0389872.04.0FalseNoneNoneFalseNoneFalse1559488.00
3089825106226Nonecode425Dialyzer reprocessing machine - 1 station. Complete specification as per engineer in chargeNos543036.0543036.04.0FalseNoneNoneFalseNoneFalse2172144.00
3089826106226Nonecode426FRP SCRUB 4FT for Negative. Complete specification as per engineer in chargeNos50822.650822.64.0FalseNoneNoneFalseNoneFalse203290.40
3089827106226Nonecode427Dialyzer holder rack for Negative - 4x4. Complete specification as per engineer in chargeNos36898.636898.64.0FalseNoneNoneFalseNoneFalse147594.40
3089828106226Nonecode428Weighing scale - wheel chair entry. Complete specification as per engineer in chargeNos52911.252911.24.0FalseNoneNoneFalseNoneFalse211644.80
3089829106226Nonecode429RO Piping (PEX Piping). Complete specification as per engineer in chargeNos389.88389.885655.0FalseNoneNoneFalseNoneFalse2204771.40
3089830106226Nonecode430Wall Station Box - Small. Complete specification as per engineer in chargeNos24367.024367.022.0FalseNoneNoneFalseNoneFalse536074.00
3089831106226Nonecode431Dialysis chairs With Weighing scale.Complete specification as per engineer in chargeNos167088.0167088.019.0FalseNoneNoneFalseNoneFalse3174672.00
3089832106226Nonecode432Bicarb Mixer. Complete specification as per engineer in chargeNos52911.252911.24.0FalseNoneNoneFalseNoneFalse211644.80
3089833106226Nonecode433Cardiac Monitor. Complete specification as per engineer in chargeNos201898.0201898.020.0FalseNoneNoneFalseNoneFalse4037960.00
3089834106226Nonecode434Suction apparatus.Complete specification as per engineer in chargeNos38987.238987.28.0FalseNoneNoneFalseNoneFalse311897.60
3089835106226Nonecode435Oxygen cylinder with trolley.Complete specification as per engineer in chargeNos27848.027848.08.0FalseNoneNoneFalseNoneFalse222784.00
3089836106226Nonecode436UPS ONLINE 10 KV / 30 min backup.Complete specification as per engineer in chargeNos278480.0278480.04.0FalseNoneNoneFalseNoneFalse1113920.00
3089837106226Nonecode437Defibrillator. Complete specification as per engineer in chargeNos348100.0348100.04.0FalseNoneNoneFalseNoneFalse1392400.00
3089838106226Nonecode438CPVC Pipings from RO system to D. Unit. Complete specification as per engineer in chargeNos69620.069620.04.0FalseNoneNoneFalseNoneFalse278480.00
3089839106226Nonecode439Electrical work for RO and D. Unit. Complete specification as per engineer in chargeNos139240.0139240.04.0FalseNoneNoneFalseNoneFalse556960.00
3089840106226Nonecode440Bed side food table.Complete specification as per engineer in chargeNos25063.225063.218.0FalseNoneNoneFalseNoneFalse451137.60
3089841106226Nonecode441Crash Cart.Complete specification as per engineer in chargeNos48734.048734.07.0FalseNoneNoneFalseNoneFalse341138.00
3089842106226Nonecode442Dressing Trolley. Complete specification as per engineer in chargeNos27848.027848.010.0FalseNoneNoneFalseNoneFalse278480.00
3089843106226Nonecode443Refrigerator - 200 Ltrs. Complete specification as per engineer in chargeNos34810.034810.04.0FalseNoneNoneFalseNoneFalse139240.00
3089844106226Nonecode444Television. Complete specification as per engineer in chargeNos34810.034810.018.0FalseNoneNoneFalseNoneFalse626580.00
3089845106226Nonecode445Air Condition system 1 Ton. Complete specification as per engineer in chargeNos90506.090506.09.0FalseNoneNoneFalseNoneFalse814554.00
3089846106226Nonecode446Artery Forceps. Complete specification as per engineer in chargeNos208.86208.86100.0FalseNoneNoneFalseNoneFalse20886.00
3089847106226Nonecode447BP Apparatus - Dial Type.Complete specification as per engineer in chargeNos2088.62088.68.0FalseNoneNoneFalseNoneFalse16708.80
3089848106226Nonecode448Bed Pan. Complete specification as per engineer in chargeNos696.2696.240.0FalseNoneNoneFalseNoneFalse27848.00
3089849106226Nonecode449Kidney Tray - SS (large size). Complete specification as per engineer in chargeNos348.1348.126.0FalseNoneNoneFalseNoneFalse9050.60
3089850106226Nonecode450Nebulizer. Complete specification as per engineer in chargeNos2088.62088.66.0FalseNoneNoneFalseNoneFalse12531.60
3089851106226Nonecode451Scissors - SS.Complete specification as per engineer in chargeNos556.96556.9616.0FalseNoneNoneFalseNoneFalse8911.360
3089852106226Nonecode452Torch. Complete specification as per engineer in chargeNos139.24139.248.0FalseNoneNoneFalseNoneFalse1113.920
3089853106226Nonecode453Urine can - Male / Female. Complete specification as per engineer in chargeNos208.86208.8625.0FalseNoneNoneFalseNoneFalse5221.50
3089854106226Nonecode454ET Tube Size - 8, 8.5, 9, 9.5. Complete specification as per engineer in chargeNos5569.65569.64.0FalseNoneNoneFalseNoneFalse22278.40
3089855106226Nonecode455Patient case Files. Complete specification as per engineer in chargeNos5569.65569.64.0FalseNoneNoneFalseNoneFalse22278.40
3089856106226Nonecode456Stationary (Dialysis case sheets). Complete specification as per engineer in chargeNos6962.06962.05.0FalseNoneNoneFalseNoneFalse34810.00
3089857106226Nonecode457Bio medical waste bins (colour coded). Complete specification as per engineer in chargeNos1392.41392.416.0FalseNoneNoneFalseNoneFalse22278.40
3089858106226Nonecode458Sthethescope. Complete specification as per engineer in chargeNos3481.03481.08.0FalseNoneNoneFalseNoneFalse27848.00
3089859106226Nonecode459Bed linen. Complete specification as per engineer in chargeNos696.2696.2234.0FalseNoneNoneFalseNoneFalse162910.80
3089860106226Nonecode460Glucometer. Complete specification as per engineer in chargeNos1392.41392.410.0FalseNoneNoneFalseNoneFalse13924.00
3089861106226Nonecode461Outdoor 50 Mts IP Cameras 4.0 Mega Pixel with LR Mounting Brackets (With IR for day & night vision Complete specification as per engineer in charge.Nos24968.824968.8149.0FalseNoneNoneFalseNoneFalse3720351.20
3089862106226Nonecode462Supply of Poles for Installation of Cameras with all required civil work Complete specification as per engineer in charge.Nos16726.516726.571.0FalseNoneNoneFalseNoneFalse1187581.50
3089863106226Nonecode463Supply of 4TB Hard Disk for storage-seagate/WDR or reputed brands Complete specification as per engineer in charge.Nos26963.026963.050.0FalseNoneNoneFalseNoneFalse1348150.00
3089864106226Nonecode464Power supply for the camera Complete specification as per engineer in charge.Nos531.0531.050.0FalseNoneNoneFalseNoneFalse26550.00
3089865106226Nonecode465Installation, erection & Commissioning charges of cameras and configuration for camera Complete specification as per engineer in charge.Nos4779.04779.0123.0FalseNoneNoneFalseNoneFalse587817.00
3089866106226Nonecode466Bracket & weather proof installation kit for 50 meter IP Camera Complete specification as per engineer in charge.Nos1787.71787.7123.0FalseNoneNoneFalseNoneFalse219887.10
3089867106226Nonecode467Supply of POE injector- TP Link/Digisol/Tenda or reputed brand Complete specification as per engineer in charge.Nos3746.53746.545.0FalseNoneNoneFalseNoneFalse168592.50
3089868106226Nonecode468Supplying & Laying of network & Power cables from camera to the control box Complete specification as per engineer in charge.Nos145.14145.142500.0FalseNoneNoneFalseNoneFalse362850.00
3089869106226Nonecode469Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.Complete specification as per engineer in charge.Sq CM0.590.59800000.0FalseNoneNoneFalseNoneFalse472000.00
3089870106226Nonecode470Supplying PVC flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely 1.9.1 20 mm Complete specification as per engineer in charge.Sq CM22.4222.42250.0FalseNoneNoneFalseNoneFalse5605.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17104987280000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17104987280000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17104987280000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17105166740000NoneNoneELIGIBILITYAll terms and conditions as per Tender Notification and KW-4 Tender documentNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneAchieved a minimum financial turnover (in all classes of civil engineering construction works only) of Rs.8080.00 Lakhs in at least two financial years. The tenderer should submit VAT/GST certificates to confirm the Annual turnover. The certificate should be duly certified by the Chartered Accountant in the turnover format. (Updated to the FY in which the tenders are invited. The value of the completed works shall be given a weight of 10% per year to bring them to the price level of the FY in which the tenders are invited)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneMandating satisfactorily completed (at least 90% of the contract value) as a prime contractor in similar nature of single work value not less than 50% (Rs.2020.00 lakhs) of the tender value. Similar nature of work means the contractor should have completed (at least 90% of the contract value). The intending bidder should submit completion certificate / work done certificate along with the contract certificate copies related to the work certified by the Engineer not less than the rank of Executive Engineer. (Updated to the FY in which the tenders are invited. The value of the completed works shall be given a weight of 10% per year to bring them to the price level of the FY in which the tenders are invited) (Work Done Certificate Along with Indent Number)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneThe intending tenderer should submit work done certificate for the following nature of work executed in last five years (2018-19 to 2022-23), the following Prime quantities executed in any last five years: (usually 80% of the peak annual rate of construction) refer KW4 documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Executed Quantities Mentioned in KW4 Doc
NoneNoneNoneNoneAvailability by owning at least 50% of the required/specified key & critical equipment for this work & the remaining 50% can be deployed on lease/hire basis for all works provided, the relevant documents (commitment agreement etc.,) for availability for this work are furnished:Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Required Machineries mentioned in KW4 doc
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs.1212.00 Lakhs (Credit lines/ letter of credit/ certificates from banks for meeting the fund requirement etc. (usually the equivalent of the estimated cash flow for three months in the peak construction period)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Company Registration CertificateTrueTechnical Bid
Work Done CertificateTrueTechnical Bid
PAN & GSTIN CertificateTrueTechnical Bid
Line of CreditTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1710517464000
version0
createdDateNone
modifiedDateNone
blockNumberChief Engineer, Bhasham Park, Sheshadripuram
streetNone
cityBengaluru
stateKarnataka
pin560003
tenderRecallDTONone