createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1710576393454
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeONE_COVER
evaluationTypeTextOne Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd45900.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose25-03-2024 16:00:00
tenderQueryClose22-03-2024 17:30:00
technicalBidOpenNone
publishedDate16-03-2024 14:25:32
publishedByPostPWD_EE_DIV_HSN
publishedByUserKPE10941 - NATESH H N
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonShwetha
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08172268437
mobileNumberNone
tenderSupplierListNone
tenderSchedule
createdTs1710576393497
version8
createdDateNone
modifiedDateNone
tenderNumberPWD/2023-24/BD/WORK_INDENT10605
titleConstruction of office room in the prenmises of Sri.Venkataramana Swamy Temple in Malekal Tirupati village ,Kasaba hobli, Arasikere tq.
descriptionConstruction of office room in the prenmises of Sri.Venkataramana Swamy Temple in Malekal Tirupati village ,Kasaba hobli, Arasikere tq.
categoryWORKS
categoryTextWorks
ecv1834487.36
deptNamePublic Works Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location1771
locationNamePWD Division Office Hassan
provisionalAmount1850000.0
groupOverheadTotal0.0
fileNumberPWD/AEE/ASK/TEMPLE
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17105763930000NoneNoneBuildingsConstruction of office room in the prenmises of Sri.Venkataramana Swamy Temple in Malekal Tirupati village ,Kasaba hobli, Arasikere tq.(Civil Work)1717510.38
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3123582107277None1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depth(Page No. 8, Item No. 1.12 of PWD SR 2023-24 Volume-1 ) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum112.1112.117.6FalseNoneNoneFalseNoneFalse1972.960
3123583107277None4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m 2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications(Page No. 5, Item No. 4.1 of PWD SR 2023-24 Volume-2 ) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm139.24139.2488.0FalseNoneNoneFalseNoneFalse12253.120
3123584107277None1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the workIn all kinds of soils Depth upto 3 m(Page No. 8, Item No. 1.14.1 of PWD SR 2023-24 Volume-1 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum120.36120.3662.14FalseNoneNoneFalseNoneFalse7479.17040
3123585107277None2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite /trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specification sMix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates(Page No. 15, Item No. 2.1.3 of PWD SR 2023-24 Volume-1 ) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum7067.027067.0213.62FalseNoneNoneFalseNoneFalse96252.81240
3123586107277None2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Page No. 16, Item No. 2.5.2 of PWD SR 2023-24 Volume-1 ) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum8074.748074.7439.12FalseNoneNoneFalseNoneFalse315883.82880
3123587107277NonePage 115 Vol-1Providing and removing form work /Centering For Footing ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum242.24242.249.0FalseNoneNoneFalseNoneFalse2180.160
3123588107277NonePage 115 Vol-1Providing and removing form work /Centering For Plinth beam ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum4037.374037.371.47FalseNoneNoneFalseNoneFalse5934.93390
3123589107277NonePage 115 Vol-1Providing and removing form work /Centering For Chajja ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum3633.633633.630.47FalseNoneNoneFalseNoneFalse1707.80610
3123590107277Nonepage 115 Vol 1Providing and removing form work /Centering For Lintel Beam, Roof beam, ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum4844.844844.845.4FalseNoneNoneFalseNoneFalse26162.1360
3123591107277Nonepage 115 vol 1Providing and removing form work /Centering For Roof slab ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum4037.374037.379.65FalseNoneNoneFalseNoneFalse38960.62050
3123592107277Nonepage 115 vol 1Providing and removing form work /Centering For Column ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum5652.325652.322.09FalseNoneNoneFalseNoneFalse11813.34880
3123593107277None5.2Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand (Page No. 9, Item No. 5.2 of PWD SR 2023-24 Volume-II ) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum7809.247809.249.38FalseNoneNoneFalseNoneFalse73250.67120
3123594107277None5.3Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (Page No. 9, Item No. 5.3 of PWD SR 2023-24 Volume-II ) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum7321.97321.97.29FalseNoneNoneFalseNoneFalse53376.6510
3123595107277None5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (Page No. 9, Item No. 5.4 of PWD SR 2023-24 Volume-II ) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum7539.027539.025.42FalseNoneNoneFalseNoneFalse40861.48840
3123596107277None1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.(Page No. 7, Item No. 1.8 of PWD SR 2022-23 Volume-1 ) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum510.94510.9428.63FalseNoneNoneFalseNoneFalse14628.21220
3123597107277None1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (Page No. 7, Item No. 1.9 of PWD SR 2023-24 Volume-1 ) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum313.88313.8850.79FalseNoneNoneFalseNoneFalse15941.96520
3123598107277None2.11(a)Steel Fabrication Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / softannealed steel wire and other ancilary operations complete as per drawing and technical specification. a.Buildings.( Page No.18, Item No.2.11(a) of PWD SR 2023-24 Volume-1 ) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Tonne105559.26105559.263.09FalseNoneNoneFalseNoneFalse326178.11340
3123599107277None21.10Providing ruled pointing to coursed stone masonry with lime mortar 1:3, 20mm deep, after raking joints to depth of 20mm nicely lining, including cost all materials, labour, usage charges of machinery, curing complete as per specification.(Page No. 214, Item No. 21.10 of PWD SR 2023-24 Volume-2) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm352.82352.8213.16FalseNoneNoneFalseNoneFalse4643.11120
3123600107277None6.7Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.(Page No. 13, Item No. 6.7 of PWD SR 2023-24 Volume-2) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum9688.989688.9820.72FalseNoneNoneFalseNoneFalse200755.66560
3123601107277None12.12Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications(Page No.99, Item No.12.12 of PWD SR 2023-24 Volume-2) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum146558.36146558.360.45FalseNoneNoneFalseNoneFalse65951.2620
3123602107277None12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. (Page No.104, Item No. 12.51 of PWD SR 2023-24 Volume-2) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Nos1198.881198.881.0FalseNoneNoneFalseNoneFalse1198.880
3123603107277None12.57.1Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-do- 30 mm thick Both side teak(Page No.105, Item No. 12.57.1 of PWD SR 2023-24 Volume-2) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm4770.744770.743.15FalseNoneNoneFalseNoneFalse15027.8310
3123604107277None12.32Providing and fixing in position Mathi / Nandi wood fully panelled shutters for windows with stiles and rails of 25mm. thick, 75mm wide in two halves with panels of 20mm thick including cost of materials, labour charges, usage charges complete as per specifications. (excluding cost of fixtures)(P.No. 102, I.No.12.32 f PWD SR 2022 Volume-2) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm4563.064563.0610.92FalseNoneNoneFalseNoneFalse49828.61520
3123605107277None8.1.2Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge(Page No.41, Item No. 8.1.2 of PWD SR 2023-24 Volume-2) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm284.38284.3886.14FalseNoneNoneFalseNoneFalse24496.49320
3123606107277None8.3.2Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge(Page No.41, Item No. 8.3.2of PWD SR 2023-24 Volume-2) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm392.94392.94151.93FalseNoneNoneFalseNoneFalse59699.37420
3123607107277None9.12.3Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete Size of Tile 800x800 mm (P.No.60 , I.No, 9.12.3 SR of 2023-24 , Volume-2) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm1483.261483.2661.62FalseNoneNoneFalseNoneFalse91398.48120
3123608107277None8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. (Page No.50, Item No. 8.54.2 ofPWD SR 2023-24 Volume-2 ) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm129.8129.8143.11FalseNoneNoneFalseNoneFalse18575.6780
3123609107277None8.30Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge .(Page No.46, Item No. 8.30 of PWD SR 2023-24 Volume-2) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm205.32205.32151.93FalseNoneNoneFalseNoneFalse31194.26760
3123610107277None8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (Page No.50, Item No. 8.51of PWD SR 2023-24 Volume-2) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm118.0118.0143.11FalseNoneNoneFalseNoneFalse16886.980
3123611107277None8.34.2Applying priming coat: With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Page No.47, Item No. 8.34.2 of PWD SR 2023-24 Volume-2) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm68.4468.4433.77FalseNoneNoneFalseNoneFalse2311.21880
3123612107277None8.38Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (P.No. 48, I.No. 8.38 of PWD 2023-24 Volume-2 ).( ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm47.247.233.77FalseNoneNoneFalseNoneFalse1593.9440
3123613107277None15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.(Page No.149, Item No.15.1 of PWD SR 2023-24 Volume-2) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm964.06964.0664.32FalseNoneNoneFalseNoneFalse62008.33920
3123614107277None11.37.3Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 8 mm thickness (weight not less than 20 kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications.(Page No 89 Item No. 11.37.3 Pof PWD SR 2023-24 Volume-2) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm1539.91539.917.6FalseNoneNoneFalseNoneFalse27102.240
17105763940001NoneNoneBuildingsConstruction of office room in the prenmises of Sri.Venkataramana Swamy Temple in Malekal Tirupati village ,Kasaba hobli, Arasikere tq.(Electrical)116976.98
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3123615107278None1.2.2Concealed Conduit System : Supplying heavy gauge PVC conduit pipe ……mm dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25mm dia 2mm thick a) 25 mm dia 2mm thick [Chapter-1, .I.no. 1.2.2] ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Mtr94.894.850.0FalseNoneNoneFalseNoneFalse4740.00
3123616107278None1.3.2Supplying heavy gauge PVC Conduit Pipe ….dia mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. a) 25 mm dia 2mm thick [Chapter-1,.I.no.1.3.2] ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Mtr96.0296.0215.0FalseNoneNoneFalseNoneFalse1440.30
3123617107278None1.5.2Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep junction box [Chapter-1.I.no.1.5.2] ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each68.0668.062.0FalseNoneNoneFalseNoneFalse136.120
3123618107278None1.13Supplyin and Fixing Metal Fan Box with Round Hook. [ Chapter-1.I.no.1.13] ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.No142.2142.26.0FalseNoneNoneFalseNoneFalse853.20
3123619107278None2.2.2Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. [Chapter-2.I.no. 2.2.2,b) Medium point above 3mtr up to 6Mtr from tapping point to out let via switch ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Point460.64460.6412.0FalseNoneNoneFalseNoneFalse5527.680
3123620107278None2.3.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. [Chapter-2.I.no. , 2.3.3]c) Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Point674.55674.555.0FalseNoneNoneFalseNoneFalse3372.750
3123621107278None2.3.1Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. [Chapter-2 .I.no.2.3.1,a) 1.0 sqmm ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Mtr23.0923.0970.0FalseNoneNoneFalseNoneFalse1616.30
3123622107278None2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. [Chapter-2 .I.no2.3.3 ) 2.5 sqmm ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Mtr51.0551.05140.0FalseNoneNoneFalseNoneFalse7147.00
3123623107278None3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/ C.C wall [ Chapter-3,I.no. 3.4.6] a) 10-12 Way ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each387.71387.716.0FalseNoneNoneFalseNoneFalse2326.260
3123624107278None3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. b) 10-12 Module [ Chapter-3,I.no. 3.5.6] b) 10-12 Module ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each418.1418.18.0FalseNoneNoneFalseNoneFalse3344.80
3123625107278None3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. [ Chapter-3, I.No.3.6.1 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each123.97123.9725.0FalseNoneNoneFalseNoneFalse3099.250
3123626107278None3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. [ Chapter-3, I.No.3.6.3,) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each207.83207.838.0FalseNoneNoneFalseNoneFalse1662.640
3123627107278None3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. [ Chapter-3, I.No.3.6.4, ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each433.9433.96.0FalseNoneNoneFalseNoneFalse2603.40
3123628107278None3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. [ Chapter-3, I.No3.6.9] ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each396.22396.221.0FalseNoneNoneFalseNoneFalse396.220
3123629107278None3.14.6Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board. a )6 Amps Pendent holder [Chapter-3.I.no. 3.14.6] ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.No86.2986.2911.0FalseNoneNoneFalseNoneFalse949.190
3123630107278None5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 32Amps. [Chapter-5.I.no.5.7.2] ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each292.91292.912.0FalseNoneNoneFalseNoneFalse585.820
3123631107278None5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 Amps DP [Chapter-5 .I.no.5.18.4] ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each898.18898.181.0FalseNoneNoneFalseNoneFalse898.180
3123632107278None5.30Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter.[Chapter-5 .I.no.5.30] ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each1677.251677.251.0FalseNoneNoneFalseNoneFalse1677.250
3123633107278None5.42.2Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 16SWG [[Chapter-5. I.no.5.42.2] ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sq CM0.520.527000.0FalseNoneNoneFalseNoneFalse3640.00
3123634107278None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200mm) Regular model [Chapter-6.I.no.6.3.1] ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each3626.753626.756.0FalseNoneNoneFalseNoneFalse21760.50
3123635107278None11.3.3Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70percentage lumen maintenance with CRIl greaterthan 80. Power Input: 220-240V @ 50/60Hz & Power factor greaterthan 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'-36/40 w [Chapter-11.I.no.11.3.3] ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each1542.341542.3410.0FalseNoneNoneFalseNoneFalse15423.40
3123636107278None12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc.,is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia [Chapter-12.I.no.12.56] ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each4266.054266.052.0FalseNoneNoneFalseNoneFalse8532.10
3123637107278None13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. .On wall / ceiling / Rafter / Girders [Chapter-13.I.no.13.7.1] ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each148.28148.2810.0FalseNoneNoneFalseNoneFalse1482.80
3123638107278None13.10Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. [Chapter-13.I.no.13.10] ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each207.83207.836.0FalseNoneNoneFalseNoneFalse1246.980
3123639107278None32.021.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 10 Sqmm, 2 Core, (9 GI Strips - 4 x 0.8 mm) [BESCO.SR 2023-24.Material commom SR.P.No.13, I.No.32.02 ] ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Km96298.5796298.570.04FalseNoneNoneFalseNoneFalse3851.94280
3123640107278None21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 2.5 to 25 Sqmm [BESCO.SR 2023-24.Labour commom SR.P.No.52, I.No.21.05 ] ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Km25384.8425384.840.04FalseNoneNoneFalseNoneFalse1015.39360
3123641107278None1.6.1Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.In all kinds of soils. Depth upto 1.50m [PWD Civil SR ,Volume-1, Chapter-1, P.No.6, I.No.1.6.1 ] ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.m588.25588.2530.0FalseNoneNoneFalseNoneFalse17647.50
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17105763940000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17105763940000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17105763940000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17105763940001NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of e-Procurement portal due to internet connectivity issues and technical glitches at bidder s end.None
17105763940001NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17105763940001NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidder.None
17105763940001NoneNoneELIGIBILITYConditional tenders will not be acceptedNone
17105763940001NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender and the employer will in no case be responsible and liable for these costsNone
17105782440000NoneNoneELIGIBILITYThe employer reserves the rights to reject one or all Tender without assigning any reasonsNone
17105782540000NoneNoneELIGIBILITYThe employer is not responsible for any delay in accessing E-Procurement PortalNone
17105782630000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt ordersNone
17105782740000NoneNoneELIGIBILITYAs per Government order LD/300/LET/2006 Bangalore dated 1.01.2007 nad Government letter no PW/134/BMS/2007 dated 27.07.2007, a sum amounting to 1% of the bill amount will be deducted towards constructions labour welfare fundNone
17105782910000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete manner otherwise it will be rejectedNone
17105783000000NoneNoneELIGIBILITYAll scanned documents to be uploaded shall be in original and the Executive Engineer reserves the right to verify the documents before approvalNone
17105783080000NoneNoneELIGIBILITYMaterials required for the work shall be procured by the tenderer themselves and should got tested by the quality control authority before use on the work.None
17105783210000NoneNoneELIGIBILITYContractors should be registered with KPWD Class IV and above RegistrationNone
17105783300000NoneNoneELIGIBILITYTo qualify for award of this contract, each tenderer should give all details and documents as per K.W-1None
17105783380000NoneNoneELIGIBILITYWork should be carried out as per K/W-1 STD attached with tender .None
17105783540000NoneNoneELIGIBILITYThe period of completion of this work is 4 MonthNone
17105783630000NoneNoneELIGIBILITYDefect Liability Period : One yearNone
17105783710000NoneNoneELIGIBILITYContractor shall bound to comply the prevailing rules and regulations with regard to the EPF Contribution rules and any modifications thereof before and after execution of agreementNone
17105783810000NoneNoneELIGIBILITYThe FSD payable at the time of executing agreement, will be refunded only after successful completion of Defect Liability PeriodNone
17105783900000NoneNoneELIGIBILITYContractors has to submit their labour EPF details with every Running BillNone
17105784110000NoneNoneELIGIBILITYThe GST shall not be paid in the extended period of contract for which the Contractor alone is responsible for delay as determined by the authority while granting the extension of time.None
17105784480000NoneNoneELIGIBILITYContractors has to upload the E P F Registration CertificateNone
17105784640000NoneNoneELIGIBILITYThe Bidders should upload Unbalanced Amount for below tenders in the form of FDR in favour of Executive Engineer, PWD Division, Hassan. Otherwise tender will not be considered. And also the successful Bidder should submit original FDR after opening of tender.Note - All the tenders will be rejected, if the same FDR is uploaded for many works.None
17105784770000NoneNoneELIGIBILITYSuccessful bidder has to furnish 0.1% of award contract amount as insurance during entering in to agreement.None
17105784940000NoneNoneELIGIBILITYEstimate rates are inclusive of 18 percentage GST .Therefore amount put to tender and ECV amount are including GST.None
17105785030000NoneNoneELIGIBILITYGST shall not be paid separately.None
preQualCriterionListNone
technicalCriterionListNone
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
KPWD Class-IV and above Registration CertificateTrueTechnical Bid
Annual Turnover Certificate certificate issued by Approved Chartered Accountant with UDIN last five years as per KW-1 i.e. 2018-19, 2019-20,2020-21, 2021-22 & 2022-23 Rs.18.34 lakhs Updated to 2023-24 price levelTrueTechnical Bid
Tenderers , will only be qualified, if their available tender capacity is more than the total tender value. i.e. A x N x 2.5 - B as per KW-1 Document.TrueTechnical Bid
Contractors has to upload the EPF Registration CertificateTrueTechnical Bid
The Bidders should upload Unbalanced Amount for below tenders in the form of FDR in favour of Executive Engineer, PWD Division, Hassan. Otherwise tender will not be considered. And also the successful Bidder should submit original FDR after opening of tender. Note - All the tenders will be rejected, if the same FDR is uploaded for many works.TrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone