3121905 | 107231 | None | code01 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. In area of light jungle | Sqm | 1155.66 | 1155.66 | 6.693 | False | None | None | False | None | False | 7734.83238 | 0 |
3121906 | 107231 | None | code02 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m consider hard soil 70% of total excavation qty | Cum | 105.06 | 105.06 | 914.74 | False | None | None | False | None | False | 96102.5844 | 0 |
3121907 | 107231 | None | code03 | In ordinary/soft rock without blasting, Depth exceeding 1.5 m, but not exceeding 3 m consider 25% of total excavation qty | Cum | 373.89 | 373.89 | 326.69 | False | None | None | False | None | False | 122146.1241 | 0 |
3121908 | 107231 | None | code04 | Earth work excavation for FOUNDATION by Mechanical means depth
upto 1.50m, as per drawing and technical specifications, including
setting out, shoring, strutting, barricading, caution lights, including cost
of explosives, dressing of excavated surfaces, disposing off or levelling
the excavated stuff or sorting & stacking the selected stuff for reuse
in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting
materials, tools, usage of Machinery & all other appurtenaces required
to complete the work In Hard Rock ( requiring blasting) Depth upto 1.50m consider 5% of total excavation qty | Cum | 570.62 | 570.62 | 65.34 | False | None | None | False | None | False | 37284.3108 | 0 |
3121909 | 107231 | None | code05 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 273.98 | 273.98 | 40.97 | False | None | None | False | None | False | 11224.9606 | 0 |
3121910 | 107231 | None | code06 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 121.54 | 121.54 | 288.0 | False | None | None | False | None | False | 35003.52 | 0 |
3121911 | 107231 | None | code07 | Removal of Unserviceable Soil with Disposal upto a suitable
distance as directed by the Engineer incharge of work ( up to 20km) | Cum | 32.96 | 32.96 | 864.0 | False | None | None | False | None | False | 28477.44 | 0 |
3121912 | 107231 | None | code08 | Providing and laying in position plain cement concrete for levelling
course for all works in foundation. The granite/trap/basalt crushed
graded coarse aggregates and fine aggregates as per relevant IS
Codes machine mixed, laid in layers not exceeding 150 mm thickness,
well compacted using plate vibrators, including all lead & lifts, cost of
all materials of quality, labour, Usage charges of machineries, curing,
and all the other appurtenances required to complete the work as per
technical specifications. (The cost of steel reinforcement & formwork
shall be paid separately)
Mix 1:3:6 (M10) Using 40 mm and down size graded crushed coarse
aggregates | Cum | 6168.67 | 6168.67 | 114.61 | False | None | None | False | None | False | 706991.2687 | 0 |
3121913 | 107231 | None | code09 | Providing and laying in position Reinforced cement concrete for all
Foundation works. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine
mixed with super plasticizers laid in finished layers, well compacted
using needle vibrators, including all lead & lifts, cost of all materials,
quality confirming to the requirements of relevant IS codes , labour,
Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications. (The cost
of steel reinforcement & formwork to be paid separately)
M25 Design Mix Using 20 mm and down size graded crushed coarse
aggregates consider 8% of finished rate of concrete for foundation upto plitnth shuttering (footing) | Cum | 7048.17 | 7048.17 | 179.57 | False | None | None | False | None | False | 1265639.8869 | 0 |
3121914 | 107231 | None | code10 | Providing and laying in position Reinforced cement concrete for all
Foundation works. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine
mixed with super plasticizers laid in finished layers, well compacted
using needle vibrators, including all lead & lifts, cost of all materials,
quality confirming to the requirements of relevant IS codes , labour,
Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications. (The cost
of steel reinforcement & formwork to be paid separately)
M25 Design Mix Using 20 mm and down size graded crushed coarse
aggregates consider 50% of finished rate of concrete for plinth beam shuttering | Cum | 9789.12 | 9789.12 | 100.36 | False | None | None | False | None | False | 982436.0832 | 0 |
3121915 | 107231 | None | code11 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates consider 70% of finished rate of concrete for column shuttering | Cum | 11982.09 | 11982.09 | 12.94 | False | None | None | False | None | False | 155048.2446 | 0 |
3121916 | 107231 | None | code12 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates consider 60% of finished rate of concrete for roof beam shuttering | Cum | 11277.26 | 11277.26 | 18.91 | False | None | None | False | None | False | 213252.9866 | 0 |
3121917 | 107231 | None | code13 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates consider 50% of finished rate of concrete for roof slab shuttering | Cum | 10572.44 | 10572.44 | 43.2 | False | None | None | False | None | False | 456729.408 | 0 |
3121918 | 107231 | None | code14 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates consider 60% of finished rate of concrete for linte lshuttering | Cum | 11277.26 | 11277.26 | 0.75 | False | None | None | False | None | False | 8457.945 | 0 |
3121919 | 107231 | None | code15 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates consider 45% of finished rate of concrete for ramp shuttering | Cum | 10220.02 | 10220.02 | 12.25 | False | None | None | False | None | False | 125195.245 | 0 |
3121920 | 107231 | None | code16 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates consider 50% of finished rate of concrete for staircase shuttering | Cum | 10572.44 | 10572.44 | 3.91 | False | None | None | False | None | False | 41338.2404 | 0 |
3121921 | 107231 | None | code17 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates GROUND FLOOR consider 70% of finished rate of concrete for column shuttering | Cum | 11982.09 | 11982.09 | 17.33 | False | None | None | False | None | False | 207649.6197 | 0 |
3121922 | 107231 | None | code18 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates GROUND FLOOR consider 60% of finished rate of concrete for roof beam shuttering | Cum | 11277.26 | 11277.26 | 25.73 | False | None | None | False | None | False | 290163.8998 | 0 |
3121923 | 107231 | None | code19 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates GROUND FLOOR consider 50% of finished rate of concrete for roof slab shuttering | Cum | 10572.44 | 10572.44 | 47.72 | False | None | None | False | None | False | 504516.8368 | 0 |
3121924 | 107231 | None | code20 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates GROUND FLOOR consider 60% of finished rate of concrete for linte lshuttering | Cum | 11277.26 | 11277.26 | 5.21 | False | None | None | False | None | False | 58754.5246 | 0 |
3121925 | 107231 | None | code21 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates GROUND FLOOR consider 45% of finished rate of concrete for chejja shuttering | Cum | 10220.02 | 10220.02 | 6.12 | False | None | None | False | None | False | 62546.5224 | 0 |
3121926 | 107231 | None | code22 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates GROUND FLOOR consider 50% of finished rate of concrete for staricase shuttering | Cum | 10572.44 | 10572.44 | 5.66 | False | None | None | False | None | False | 59840.0104 | 0 |
3121927 | 107231 | None | code23 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates GROUND FLOOR consider 50% of finished rate of concrete for shear wall shuttering | Cum | 10572.44 | 10572.44 | 6.15 | False | None | None | False | None | False | 65020.506 | 0 |
3121928 | 107231 | None | code24 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FIRST FLOOR consider 70% of finished rate of concrete for column shuttering | Cum | 12101.91 | 12101.91 | 17.33 | False | None | None | False | None | False | 209726.1003 | 0 |
3121929 | 107231 | None | code25 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FIRST FLOOR consider 60% of finished rate of concrete for roof beam shuttering | Cum | 11390.04 | 11390.04 | 21.24 | False | None | None | False | None | False | 241924.4496 | 0 |
3121930 | 107231 | None | code26 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FIRST FLOOR consider 50% of finished rate of concrete for roof slab shuttering | Cum | 10678.16 | 10678.16 | 43.2 | False | None | None | False | None | False | 461296.512 | 0 |
3121931 | 107231 | None | code27 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FIRST FLOOR consider 60% of finished rate of concrete for linte lshuttering | Cum | 11390.04 | 11390.04 | 4.69 | False | None | None | False | None | False | 53419.2876 | 0 |
3121932 | 107231 | None | code28 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FIRST FLOOR consider 45% of finished rate of concrete for chejja shuttering | Cum | 10322.22 | 10322.22 | 6.12 | False | None | None | False | None | False | 63171.9864 | 0 |
3121933 | 107231 | None | code29 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FIRST FLOOR consider 50% of finished rate of concrete for staricase shuttering | Cum | 10678.16 | 10678.16 | 5.66 | False | None | None | False | None | False | 60438.3856 | 0 |
3121934 | 107231 | None | code30 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FIRST FLOOR consider 50% of finished rate of concrete for shear wall shuttering | Cum | 10678.16 | 10678.16 | 6.15 | False | None | None | False | None | False | 65670.684 | 0 |
3121935 | 107231 | None | code31 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates TERRACE FLOOR consider 70% of finished rate of concrete for column shuttering | Cum | 12221.73 | 12221.73 | 6.24 | False | None | None | False | None | False | 76263.5952 | 0 |
3121936 | 107231 | None | code32 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates TERRACE FLOOR consider 60% of finished rate of concrete for roof beam shuttering | Cum | 11502.81 | 11502.81 | 2.18 | False | None | None | False | None | False | 25076.1258 | 0 |
3121937 | 107231 | None | code33 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates TERRACE FLOOR consider 50% of finished rate of concrete for roof slab shuttering | Cum | 10783.88 | 10783.88 | 4.07 | False | None | None | False | None | False | 43890.3916 | 0 |
3121938 | 107231 | None | code34 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates TERRACE FLOOR consider 60% of finished rate of concrete for linte lshuttering | Cum | 11502.81 | 11502.81 | 0.45 | False | None | None | False | None | False | 5176.2645 | 0 |
3121939 | 107231 | None | code35 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates TERRACE FLOOR consider 45% of finished rate of concrete for chejja shuttering | Cum | 10424.42 | 10424.42 | 0.16 | False | None | None | False | None | False | 1667.9072 | 0 |
3121940 | 107231 | None | code36 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates TERRACE FLOOR consider 50% of finished rate of concrete for shear wall shuttering | Cum | 10783.88 | 10783.88 | 7.38 | False | None | None | False | None | False | 79585.0344 | 0 |
3121941 | 107231 | None | code37 | Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | t | 92140.71 | 92140.71 | 35.53 | False | None | None | False | None | False | 3273759.4263 | 0 |
3121942 | 107231 | None | code38 | Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) G.F | t | 92140.71 | 92140.71 | 16.26 | False | None | None | False | None | False | 1498207.9446 | 0 |
3121943 | 107231 | None | code39 | Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) F.F | t | 93062.12 | 93062.12 | 15.49 | False | None | None | False | None | False | 1441532.2388 | 0 |
3121944 | 107231 | None | code40 | Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) TERRACE | t | 93983.52 | 93983.52 | 3.33 | False | None | None | False | None | False | 312965.1216 | 0 |
3121945 | 107231 | None | code41 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1349.3 | 1349.3 | 33.78 | False | None | None | False | None | False | 45579.354 | 0 |
3121946 | 107231 | None | code42 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. G.F | Sqm | 1349.3 | 1349.3 | 503.82 | False | None | None | False | None | False | 679804.326 | 0 |
3121947 | 107231 | None | code43 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. F.F | Sqm | 1362.79 | 1362.79 | 494.31 | False | None | None | False | None | False | 673640.7249 | 0 |
3121948 | 107231 | None | code44 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. TERRACE | Sqm | 1376.29 | 1376.29 | 124.1 | False | None | None | False | None | False | 170797.589 | 0 |
3121949 | 107231 | None | code45 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1137.12 | 1137.12 | 85.65 | False | None | None | False | None | False | 97394.328 | 0 |
3121950 | 107231 | None | code46 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1148.49 | 1148.49 | 34.05 | False | None | None | False | None | False | 39106.0845 | 0 |
3121951 | 107231 | None | code47 | Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 101779.45 | 101779.45 | 0.36 | False | None | None | False | None | False | 36640.602 | 0 |
3121952 | 107231 | None | code48 | Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 101779.45 | 101779.45 | 0.4 | False | None | None | False | None | False | 40711.78 | 0 |
3121953 | 107231 | None | code49 | Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 102797.24 | 102797.24 | 0.53 | False | None | None | False | None | False | 54482.5372 | 0 |
3121954 | 107231 | None | code50 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial | Sqm | 3421.66 | 3421.66 | 4.98 | False | None | None | False | None | False | 17039.8668 | 0 |
3121955 | 107231 | None | code51 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial | Sqm | 3421.66 | 3421.66 | 7.2 | False | None | None | False | None | False | 24635.952 | 0 |
3121956 | 107231 | None | code52 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial | Sqm | 3455.88 | 3455.88 | 9.6 | False | None | None | False | None | False | 33176.448 | 0 |
3121957 | 107231 | None | code53 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. | m | 327.54 | 327.54 | 34.2 | False | None | None | False | None | False | 11201.868 | 0 |
3121958 | 107231 | None | code54 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. | m | 330.82 | 330.82 | 17.1 | False | None | None | False | None | False | 5657.022 | 0 |
3121959 | 107231 | None | code55 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges -do- with both side prelam | Sqm | 2436.98 | 2436.98 | 9.45 | False | None | None | False | None | False | 23029.461 | 0 |
3121960 | 107231 | None | code56 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges -do- with both side prelam | Sqm | 2461.35 | 2461.35 | 4.73 | False | None | None | False | None | False | 11642.1855 | 0 |
3121961 | 107231 | None | code57 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications | Nos | 1046.48 | 1046.48 | 2.0 | False | None | None | False | None | False | 2092.96 | 0 |
3121962 | 107231 | None | code58 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications | Nos | 1046.48 | 1046.48 | 9.0 | False | None | None | False | None | False | 9418.32 | 0 |
3121963 | 107231 | None | code59 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications | Nos | 1056.94 | 1056.94 | 7.0 | False | None | None | False | None | False | 7398.58 | 0 |
3121964 | 107231 | None | code60 | Providing & fixing of 3track x 2panel sliding windows made out of multi chambered UPVC(Matching to RAL9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 6936.02 | 6936.02 | 1.8 | False | None | None | False | None | False | 12484.836 | 0 |
3121965 | 107231 | None | code61 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 6936.02 | 6936.02 | 42.12 | False | None | None | False | None | False | 292145.1624 | 0 |
3121966 | 107231 | None | code62 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 7005.38 | 7005.38 | 37.26 | False | None | None | False | None | False | 261020.4588 | 0 |
3121967 | 107231 | None | code63 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 5890.57 | 5890.57 | 4.32 | False | None | None | False | None | False | 25447.2624 | 0 |
3121968 | 107231 | None | code64 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 5949.48 | 5949.48 | 1.62 | False | None | None | False | None | False | 9638.1576 | 0 |
3121969 | 107231 | None | code65 | Providing and fixing 12 mm thick frameless toughened glass door
shutter of approved brand and manufacture, including providing and
fixing top & bottom pivot & double acting hydraulic floor spring type
fixing arrangement and making necessary holes etc. for fixing required
door fittings, all complete as per direction of Engineer-in-charge (Door
handle, lock and stopper etc. to be paid separately) including cost
of materials, labour, usage charges of machinery complete as per
specifications and as per directions of the Engineer-in-Charge. | Sqm | 4863.66 | 4863.66 | 29.34 | False | None | None | False | None | False | 142699.7844 | 0 |
3121970 | 107231 | None | code66 | Providing and fixing 12 mm thick frameless toughened glass door
shutter of approved brand and manufacture, including providing and
fixing top & bottom pivot & double acting hydraulic floor spring type
fixing arrangement and making necessary holes etc. for fixing required
door fittings, all complete as per direction of Engineer-in-charge (Door
handle, lock and stopper etc. to be paid separately) including cost
of materials, labour, usage charges of machinery complete as per
specifications and as per directions of the Engineer-in-Charge. | Sqm | 4912.3 | 4912.3 | 20.88 | False | None | None | False | None | False | 102568.824 | 0 |
3121971 | 107231 | None | code67 | Providing 12 mm cement plaster finished with a floating coat of neat
cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including
rounding off corners wherever required smooth rendering, providing and
removing scaffolding, including cost of materials, labour, curing complete
as per specifications and as per directions of Engineer-in-charge. | Sqm | 321.36 | 321.36 | 31.29 | False | None | None | False | None | False | 10055.3544 | 0 |
3121972 | 107231 | None | code68 | Providing 12 mm cement plaster finished with a floating coat of neat
cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including
rounding off corners wherever required smooth rendering, providing and
removing scaffolding, including cost of materials, labour, curing complete
as per specifications and as per directions of Engineer-in-charge. | Sqm | 321.36 | 321.36 | 1134.14 | False | None | None | False | None | False | 364467.2304 | 0 |
3121973 | 107231 | None | code69 | Providing 12 mm cement plaster finished with a floating coat of neat
cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including
rounding off corners wherever required smooth rendering, providing and
removing scaffolding, including cost of materials, labour, curing complete
as per specifications and as per directions of Engineer-in-charge. | Sqm | 324.57 | 324.57 | 1000.11 | False | None | None | False | None | False | 324605.7027 | 0 |
3121974 | 107231 | None | code70 | Providing 12 mm cement plaster finished with a floating coat of neat
cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including
rounding off corners wherever required smooth rendering, providing and
removing scaffolding, including cost of materials, labour, curing complete
as per specifications and as per directions of Engineer-in-charge. | Sqm | 327.79 | 327.79 | 94.35 | False | None | None | False | None | False | 30926.9865 | 0 |
3121975 | 107231 | None | code71 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement:
3 coarse sand) finished with a floating coat of neat cement on the rough
side of single or half brick wall including rounding off corners wherever
required smooth rendering, providing and removing scaffolding, including
cost of materials, labour, curing complete as per specifications and as per
directions of Engineer-in-charge. | Sqm | 376.98 | 376.98 | 204.0 | False | None | None | False | None | False | 76903.92 | 0 |
3121976 | 107231 | None | code72 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement:
3 coarse sand) finished with a floating coat of neat cement on the rough
side of single or half brick wall including rounding off corners wherever
required smooth rendering, providing and removing scaffolding, including
cost of materials, labour, curing complete as per specifications and as per
directions of Engineer-in-charge. | Sqm | 376.98 | 376.98 | 575.78 | False | None | None | False | None | False | 217057.5444 | 0 |
3121977 | 107231 | None | code73 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement:
3 coarse sand) finished with a floating coat of neat cement on the rough
side of single or half brick wall including rounding off corners wherever
required smooth rendering, providing and removing scaffolding, including
cost of materials, labour, curing complete as per specifications and as per
directions of Engineer-in-charge. | Sqm | 380.75 | 380.75 | 575.78 | False | None | None | False | None | False | 219228.235 | 0 |
3121978 | 107231 | None | code74 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement:
3 coarse sand) finished with a floating coat of neat cement on the rough
side of single or half brick wall including rounding off corners wherever
required smooth rendering, providing and removing scaffolding, including
cost of materials, labour, curing complete as per specifications and as per
directions of Engineer-in-charge. | Sqm | 384.52 | 384.52 | 245.0 | False | None | None | False | None | False | 94207.4 | 0 |
3121979 | 107231 | None | code75 | Extra for providing and mixing water proofing material in cement plaster
work in proportion recommended by the manufacturers including cost of
material etc as per specifications and as per directions of the Engineerin-
Charge. | Kg | 65.92 | 65.92 | 1164.0 | False | None | None | False | None | False | 76730.88 | 0 |
3121980 | 107231 | None | code76 | Providing 12 mm cement plaster finished with a floating coat of neat
cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including
rounding off corners wherever required smooth rendering, providing and
removing scaffolding, including cost of materials, labour, curing complete
as per specifications and as per directions of Engineer-in-charge. | Sqm | 321.36 | 321.36 | 227.28 | False | None | None | False | None | False | 73038.7008 | 0 |
3121981 | 107231 | None | code77 | Providing 12 mm cement plaster finished with a floating coat of neat
cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including
rounding off corners wherever required smooth rendering, providing and
removing scaffolding, including cost of materials, labour, curing complete
as per specifications and as per directions of Engineer-in-charge. | Sqm | 324.57 | 324.57 | 157.44 | False | None | None | False | None | False | 51100.3008 | 0 |
3121982 | 107231 | None | code78 | Finishing with Epoxy paint (two coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Enginer-in-charge. | Sqm | 181.28 | 181.28 | 45.0 | False | None | None | False | None | False | 8157.6 | 0 |
3121983 | 107231 | None | code79 | Finishing with Epoxy paint (two coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Enginer-in-charge. | Sqm | 183.09 | 183.09 | 38.34 | False | None | None | False | None | False | 7019.6706 | 0 |
3121984 | 107231 | None | code80 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 142.14 | 142.14 | 6.8 | False | None | None | False | None | False | 966.552 | 0 |
3121985 | 107231 | None | code81 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 142.14 | 142.14 | 8.52 | False | None | None | False | None | False | 1211.0328 | 0 |
3121986 | 107231 | None | code82 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 143.56 | 143.56 | 8.52 | False | None | None | False | None | False | 1223.1312 | 0 |
3121987 | 107231 | None | code83 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 162.74 | 162.74 | 625.29 | False | None | None | False | None | False | 101759.6946 | 0 |
3121988 | 107231 | None | code84 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 162.74 | 162.74 | 1728.14 | False | None | None | False | None | False | 281237.5036 | 0 |
3121989 | 107231 | None | code85 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 164.37 | 164.37 | 1594.11 | False | None | None | False | None | False | 262023.8607 | 0 |
3121990 | 107231 | None | code86 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 165.99 | 165.99 | 126.85 | False | None | None | False | None | False | 21055.8315 | 0 |
3121991 | 107231 | None | code87 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 103.0 | 103.0 | 625.29 | False | None | None | False | None | False | 64404.87 | 0 |
3121992 | 107231 | None | code88 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 103.0 | 103.0 | 1728.14 | False | None | None | False | None | False | 177998.42 | 0 |
3121993 | 107231 | None | code89 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 104.03 | 104.03 | 1594.11 | False | None | None | False | None | False | 165835.2633 | 0 |
3121994 | 107231 | None | code90 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 105.06 | 105.06 | 126.85 | False | None | None | False | None | False | 13326.861 | 0 |
3121995 | 107231 | None | code91 | Providing Lath plaster with cement mortar 1:3 5cm thick with 6mm dia mild steel bars at 20cms. C to c both horizontally and vertically fixing chicken mesh for drop chejjas, facia, backing to cup board including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specification. | Sqm | 1275.14 | 1275.14 | 18.0 | False | None | None | False | None | False | 22952.52 | 0 |
3121996 | 107231 | None | code92 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 183.34 | 183.34 | 786.0 | False | None | None | False | None | False | 144105.24 | 0 |
3121997 | 107231 | None | code93 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 183.34 | 183.34 | 575.78 | False | None | None | False | None | False | 105563.5052 | 0 |
3121998 | 107231 | None | code94 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 185.17 | 185.17 | 575.78 | False | None | None | False | None | False | 106617.1826 | 0 |
3121999 | 107231 | None | code95 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 187.01 | 187.01 | 245.0 | False | None | None | False | None | False | 45817.45 | 0 |
3122000 | 107231 | None | code96 | Providing and laying flooring and steps machine cut granite slabs 40
mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement
mortar 1:3 over existing cement concrete bed , including cost of
materials, mortar labour, curing complete as per specifications. | Sqm | 4407.37 | 4407.37 | 8.34 | False | None | None | False | None | False | 36757.4658 | 0 |
3122001 | 107231 | None | code97 | Providing and laying flooring and steps machine cut granite slabs 40
mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement
mortar 1:3 over existing cement concrete bed , including cost of
materials, mortar labour, curing complete as per specifications. | Sqm | 4451.44 | 4451.44 | 6.0 | False | None | None | False | None | False | 26708.64 | 0 |
3122002 | 107231 | None | code98 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. | Sqm | 1210.25 | 1210.25 | 15.5 | False | None | None | False | None | False | 18758.875 | 0 |
3122003 | 107231 | None | code99 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. | Sqm | 1210.25 | 1210.25 | 146.73 | False | None | None | False | None | False | 177579.9825 | 0 |
3122004 | 107231 | None | code100 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. | Sqm | 1222.35 | 1222.35 | 212.74 | False | None | None | False | None | False | 260042.739 | 0 |
3122005 | 107231 | None | code101 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. | Sqm | 2937.56 | 2937.56 | 109.28 | False | None | None | False | None | False | 321016.5568 | 0 |
3122006 | 107231 | None | code102 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. | Sqm | 2937.56 | 2937.56 | 184.31 | False | None | None | False | None | False | 541421.6836 | 0 |
3122007 | 107231 | None | code103 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. | Sqm | 2966.94 | 2966.94 | 117.88 | False | None | None | False | None | False | 349742.8872 | 0 |
3122008 | 107231 | None | code104 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. | Sqm | 915.67 | 915.67 | 32.85 | False | None | None | False | None | False | 30079.7595 | 0 |
3122009 | 107231 | None | code105 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. | Sqm | 924.83 | 924.83 | 10.2 | False | None | None | False | None | False | 9433.266 | 0 |
3122010 | 107231 | None | code106 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. | Sqm | 1492.47 | 1492.47 | 227.28 | False | None | None | False | None | False | 339208.5816 | 0 |
3122011 | 107231 | None | code107 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. | Sqm | 1507.39 | 1507.39 | 157.44 | False | None | None | False | None | False | 237323.4816 | 0 |
3122012 | 107231 | None | code108 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kg | 173.04 | 173.04 | 37.8 | False | None | None | False | None | False | 6540.912 | 0 |
3122013 | 107231 | None | code109 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kg | 173.04 | 173.04 | 975.24 | False | None | None | False | None | False | 168755.5296 | 0 |
3122014 | 107231 | None | code110 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kg | 174.77 | 174.77 | 873.18 | False | None | None | False | None | False | 152605.6686 | 0 |
3122015 | 107231 | None | code111 | Providing and laying in position Reinforced cement concrete for all
Sub structures of building, Irrigation works, Sub structure works of
bridges, Drain works & other parallel works from 0.50m to 3.50 m
height. The granite/trap/basalt crushed graded coarse aggregates and
fine aggregates as per relevant IS Codes machine mixed with super
plasticisers, laid in layers, well compacted using needle vibrators,
providing weep holes wherever necesary, including all lead & lifts, cost
of all materials of quality, confirming to the requirements of relevant
IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical
specifications. (The cost of steel reinforcement & formwork to be paid
separately) | Cum | 6596.12 | 6596.12 | 0.5 | False | None | None | False | None | False | 3298.06 | 0 |
3122016 | 107231 | None | code112 | Providing and laying in position Reinforced cement concrete for all
Sub structures of building, Irrigation works, Sub structure works of
bridges, Drain works & other parallel works from 0.50m to 3.50 m
height. The granite/trap/basalt crushed graded coarse aggregates and
fine aggregates as per relevant IS Codes machine mixed with super
plasticisers, laid in layers, well compacted using needle vibrators,
providing weep holes wherever necesary, including all lead & lifts, cost
of all materials of quality, confirming to the requirements of relevant
IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical
specifications. (The cost of steel reinforcement & formwork to be paid
separately) | Cum | 6596.12 | 6596.12 | 24.25 | False | None | None | False | None | False | 159955.91 | 0 |
3122017 | 107231 | None | code113 | Providing and laying in position Reinforced cement concrete for all
Sub structures of building, Irrigation works, Sub structure works of
bridges, Drain works & other parallel works from 0.50m to 3.50 m
height. The granite/trap/basalt crushed graded coarse aggregates and
fine aggregates as per relevant IS Codes machine mixed with super
plasticisers, laid in layers, well compacted using needle vibrators,
providing weep holes wherever necesary, including all lead & lifts, cost
of all materials of quality, confirming to the requirements of relevant
IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical
specifications. (The cost of steel reinforcement & formwork to be paid
separately) | Cum | 6662.08 | 6662.08 | 5.16 | False | None | None | False | None | False | 34376.3328 | 0 |
3122018 | 107231 | None | code114 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 581.95 | 581.95 | 200.0 | False | None | None | False | None | False | 116390.0 | 0 |
3122019 | 107231 | None | code115 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 581.95 | 581.95 | 560.0 | False | None | None | False | None | False | 325892.0 | 0 |
3122020 | 107231 | None | code116 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 587.77 | 587.77 | 200.0 | False | None | None | False | None | False | 117554.0 | 0 |
3122021 | 107231 | None | code117 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 841.51 | 841.51 | 27.45 | False | None | None | False | None | False | 23099.4495 | 0 |
3122022 | 107231 | None | code118 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 849.93 | 849.93 | 10.2 | False | None | None | False | None | False | 8669.286 | 0 |
3122023 | 107231 | None | code119 | Providing and laying 52 mm thick cement concrete flooring with concrete
hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1
cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal
size) and top layer 12 mm thick cement hardener consisting of mix 1:2
(1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size)
by volume, hardening compound mixed @ 2 litre per 50 kg of cement
or as per direction of Engineer incharge. | Sqm | 824.0 | 824.0 | 444.8 | False | None | None | False | None | False | 366515.2 | 0 |
3122024 | 107231 | None | code120 | Providing and laying 52 mm thick cement concrete flooring with concrete
hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1
cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal
size) and top layer 12 mm thick cement hardener consisting of mix 1:2
(1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size)
by volume, hardening compound mixed @ 2 litre per 50 kg of cement
or as per direction of Engineer incharge. | Sqm | 824.0 | 824.0 | 73.5 | False | None | None | False | None | False | 60564.0 | 0 |
3122025 | 107231 | None | code121 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15
cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs,
laid to slope compacting, including cost of materials, labour, curing
complete as per specifications. | Cum | 2077.51 | 2077.51 | 4.12 | False | None | None | False | None | False | 8559.3412 | 0 |
3122026 | 107231 | None | code122 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15
cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs,
laid to slope compacting, including cost of materials, labour, curing
complete as per specifications. | Cum | 2098.29 | 2098.29 | 1.53 | False | None | None | False | None | False | 3210.3837 | 0 |
3122027 | 107231 | None | code123 | Providing and supplying crystalline integral concrete waterproofing
admixture that waterproofs concrete by forming crystals deep in
the pores, capillaries and microcracks of the concrete, self-seal
waterproofing compound to bridge shrinkage cracks upto 0.5mm in
width & resist hydro-static pressure upto 16bar for both positive &
negative pressure confirming to DIN 1048 part 5 for 56% reduction in
depth of penetration against control, resistance to chloride penetration
confirming to ASTM C 1202 with 64% improvement against control &
protecting steel re-inforcement against corrosion mixed @ 1% by weight
of cementitious content in concrete. ie., integral crystaline waterproofing
admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of
Cement for M-20 grade of Concrete is considered in the analysis) | Sqm | 633.45 | 633.45 | 288.0 | False | None | None | False | None | False | 182433.6 | 0 |
3122028 | 107231 | None | code124 | INTERNAL WATER SUPPLY & SANITORY WORK Earth work excavation for Foundation by manual means for all Buildings,
Bridges, Retaining walls, Abutment Piers and such similar works
as per drawing and technical Specifications, including setting out, providing
shoring & strutting,barricading, caution lights, removal of stumps
and other deleterious matter, including dressing of excavated surfaces,
disposing off or levelling the excavated earth or sorting & stacking the
selected earth for reuse in a radius of 50 m and lift upto 1.5 m including
cost of labour, tools, usage& other appurtenances required to complete
the work.
Depth exceeding 1.5m, but not exceeding 3 m | Cum | 498.52 | 498.52 | 15.0 | False | None | None | False | None | False | 7477.8 | 0 |
3122029 | 107231 | None | code125 | Filling available excavated earth (excluding rock) in trenches, plinth,
sides of foundations and other similar works etc. in layers not exceeding
20cm in depth, consolidating each deposited layer by ramming and
watering, lead up to 50 m and lift upto 1.5 m. | Cum | 273.98 | 273.98 | 15.0 | False | None | None | False | None | False | 4109.7 | 0 |
3122030 | 107231 | None | code126 | Providing and fixing 3 layer PP-R (Poly Propylene Random Copolymer)
pipes confirming to IS.15801: 2008 OR WRAS, NSF certificates which is
UV stabilized and anti-microbial fusion welded, having thermal stability
for hot and cold water supply, including all PP-R plain and brass threaded
polypropylene random fittings, including fixing the pipe with clamps at
1.00 m spacing. This includes Lot wise test report as per the relevant IS/
ISO/DIN/BIS codes and also testing of joints complete as per direction
of Engineer-In- Charge.etc. complete PN - 16 Pipe, SDR 7.4 -16 mm OD | m | 195.7 | 195.7 | 130.0 | False | None | None | False | None | False | 25441.0 | 0 |
3122031 | 107231 | None | code127 | Providing and fixing 3 layer PP-R (Poly Propylene Random Copolymer)
pipes confirming to IS.15801: 2008 OR WRAS, NSF certificates which is
UV stabilized and anti-microbial fusion welded, having thermal stability
for hot and cold water supply, including all PP-R plain and brass threaded
polypropylene random fittings, including fixing the pipe with clamps at
1.00 m spacing. This includes Lot wise test report as per the relevant IS/
ISO/DIN/BIS codes and also testing of joints complete as per direction
of Engineer-In- Charge.etc. complete PN - 16 Pipe, SDR 7.4 -20 mm OD | m | 211.15 | 211.15 | 120.0 | False | None | None | False | None | False | 25338.0 | 0 |
3122032 | 107231 | None | code128 | Providing and fixing 3 layer PP-R (Poly Propylene Random Copolymer)
pipes confirming to IS.15801: 2008 OR WRAS, NSF certificates which is
UV stabilized and anti-microbial fusion welded, having thermal stability
for hot and cold water supply, including all PP-R plain and brass threaded
polypropylene random fittings, including fixing the pipe with clamps at
1.00 m spacing. This includes Lot wise test report as per the relevant IS/
ISO/DIN/BIS codes and also testing of joints complete as per direction
of Engineer-In- Charge.etc. complete PN - 16 Pipe, SDR 7.4-25 mm OD | m | 261.62 | 261.62 | 102.0 | False | None | None | False | None | False | 26685.24 | 0 |
3122033 | 107231 | None | code129 | Providing and fixing 3 layer PP-R (Poly Propylene Random Copolymer)
pipes confirming to IS.15801: 2008 OR WRAS, NSF certificates which is
UV stabilized and anti-microbial fusion welded, having thermal stability
for hot and cold water supply, including all PP-R plain and brass threaded
polypropylene random fittings, including fixing the pipe with clamps at
1.00 m spacing. This includes Lot wise test report as per the relevant IS/
ISO/DIN/BIS codes and also testing of joints complete as per direction
of Engineer-In- Charge.etc. complete PN - 16 Pipe,SDR 7.4- 32 mm OD | m | 355.35 | 355.35 | 140.0 | False | None | None | False | None | False | 49749.0 | 0 |
3122034 | 107231 | None | code130 | Providing and fixing water closet squatting pan (Indian type W.C. pan )
with 100 mm sand cast Iron P or S trap, 10 litre low level white
P.V.C. flushing cistern, including flush pipe, with manually controlled
device (handle lever) conforming to IS : 7231, with all fittings and
fixtures complete, including cutting and making good the walls and
floors wherever required: | Each | 5030.52 | 5030.52 | 9.0 | False | None | None | False | None | False | 45274.68 | 0 |
3122035 | 107231 | None | code131 | Providing and fixing PTMT towel rail complete with brackets fixed to
wooden cleats with CP brass screws with concealed fittings arrangement
of approved quality and colour.
600 mm long towel rail with total length of 645 mm, width 78 mm and
effective height of 88 mm, weighing not less than 190 g. | Unit | 510.88 | 510.88 | 10.0 | False | None | None | False | None | False | 5108.8 | 0 |
3122036 | 107231 | None | code132 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : | Each | 4587.62 | 4587.62 | 2.0 | False | None | None | False | None | False | 9175.24 | 0 |
3122037 | 107231 | None | code133 | Providing and fixing brass bib cock of approved quality : 15 mm nominal bore | Nos | 294.58 | 294.58 | 21.0 | False | None | None | False | None | False | 6186.18 | 0 |
3122038 | 107231 | None | code134 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass
single hole basin mixer of approved quality and make, including painting
of fittings and brackets, cutting and making good the walls wherever
required: using White Vitreous China Wash basin size 550x400 mm
with a 15 mm CP Brass single hole basin mixer | Each | 2951.98 | 2951.98 | 8.0 | False | None | None | False | None | False | 23615.84 | 0 |
3122039 | 107231 | None | code135 | Providing and fixing Brass full way valve gate with C.I. wheel of
approved quality (screwed end) : 25 mm nominal bore | Each | 565.47 | 565.47 | 4.0 | False | None | None | False | None | False | 2261.88 | 0 |
3122040 | 107231 | None | code136 | Providing and fixing Brass full way valve gate with C.I. wheel of
approved quality (screwed end) : 32 mm nominal bore | Each | 615.94 | 615.94 | 3.0 | False | None | None | False | None | False | 1847.82 | 0 |
3122041 | 107231 | None | code137 | Providing and fixing Brass full way valve gate with C.I. wheel of
approved quality (screwed end) : 40 mm nominal bore | Each | 723.06 | 723.06 | 4.0 | False | None | None | False | None | False | 2892.24 | 0 |
3122042 | 107231 | None | code138 | Constructing brick masonry chamber for underground C.I. inspection
chamber and bends with bricks in cement mortar 1:4 (1 cement : 4
coarse sand) C.I. cover with frame (light duty) 455x610 mm internal
dimensions, total weight of cover with frame to be not less than 38
kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab
with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20
mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand
: 10 graded stone aggregate 40 mm nominal size), inside plastering 12
mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished
smooth with a floating coat of neat cement on walls and bed concrete etc.
complete as per standard design: Inside dimensions 455x610 mm and
45 cm deep for single pipe line : With common burnt clay | Nos | 5811.26 | 5811.26 | 8.0 | False | None | None | False | None | False | 46490.08 | 0 |
3122043 | 107231 | None | code139 | Providing and fixing square mouth SW gully trap class sp 1 complete with ci gratings brick masonery chamber 100 x 100 mm size p type with non modular common burnt brick of designation 3.5 & water tight ci cover with frame of 300 x 300mm size (inside) the weight of cover to be not less than 4.5kg and frame to be not less than 2.7 kg as per standard design | Each | 2607.96 | 2607.96 | 12.0 | False | None | None | False | None | False | 31295.52 | 0 |
3122044 | 107231 | None | code140 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per
IS:13983 with C.I. brackets and stainless steel plug 40 mm, including
painting of fittings and brackets, cutting and making good the walls
wherever required : 510x1040 mm bowl depth 250 mm | Each | 5786.54 | 5786.54 | 2.0 | False | None | None | False | None | False | 11573.08 | 0 |
3122045 | 107231 | None | code141 | Providing and fixing granite stone slab with table rubbed, edges rounded
and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal
partitions by cutting a chase of appropriate width with chase cutter and
embedding the stone in the chase with epoxy grout or with cement
concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6
mm nominal size) as per direction of Engineer-in- charge and finished
smooth. | Sqm | 2872.67 | 2872.67 | 2.1 | False | None | None | False | None | False | 6032.607 | 0 |
3122046 | 107231 | None | code142 | Providing and fixing trap of self cleaning design with screwed down or hinged grating with or without vent arm complete , including cost of cutting and making good for walls and floors 100mm inlet and 100mm out let | Each | 687.01 | 687.01 | 21.0 | False | None | None | False | None | False | 14427.21 | 0 |
3122047 | 107231 | None | code143 | Providing and fixing C.P. brass long nose bib cock of approved quality
conforming to IS standards and weighing not less than 810 g. | Each | 871.38 | 871.38 | 8.0 | False | None | None | False | None | False | 6971.04 | 0 |
3122048 | 107231 | None | code144 | Providing and fixing C.P. brass stop cock (concealed) of standard design
and of approved make conforming to IS:8931. | Each | 746.75 | 746.75 | 4.0 | False | None | None | False | None | False | 2987.0 | 0 |
3122049 | 107231 | None | code145 | Providing and fixing 3 layer PP-R (Poly Propylene Random Copolymer) pipes confirming to IS.15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply, including all PP-R plain and brass threaded polypropylene random fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer-In- Charge. PN - 16 Pipe,SDR 7.4-40 mm OD | m | 517.06 | 517.06 | 120.0 | False | None | None | False | None | False | 62047.2 | 0 |
3122050 | 107231 | None | code146 | Providing and fixing 3 layer PP-R (Poly Propylene Random Copolymer) pipes confirming to IS.15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply, including all PP-R plain and brass threaded polypropylene random fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer-In- Charge. PN - 16 Pipe,SDR 7.4- 32 mm OD | m | 355.35 | 355.35 | 110.0 | False | None | None | False | None | False | 39088.5 | 0 |
3122051 | 107231 | None | code147 | Providing and fixing 3 layer PP-R (Poly Propylene Random Copolymer) pipes confirming to IS.15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply, including all PP-R plain and brass threaded polypropylene random fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer-In- Charge. PN - 16 Pipe,SDR 7.4-63 mm OD | m | 972.32 | 972.32 | 140.0 | False | None | None | False | None | False | 136124.8 | 0 |
3122052 | 107231 | None | code148 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 140mm dia., 6 kg/sqcm & class 3 | m | 601.52 | 601.52 | 130.0 | False | None | None | False | None | False | 78197.6 | 0 |
3122053 | 107231 | None | code149 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 | m | 423.33 | 423.33 | 180.0 | False | None | None | False | None | False | 76199.4 | 0 |
3122054 | 107231 | None | code150 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 75mm dia., 6 kg/sqcm & class 3 | m | 226.6 | 226.6 | 120.0 | False | None | None | False | None | False | 27192.0 | 0 |
3122055 | 107231 | None | code151 | Providing and placing on terrace polyethylene water storage tanks as per IS : 12701 : 1996 with manhole lid and suitable locking arrangements, aking holes of suitable diameter for inlet, outlet and overflow pipes, includng cost of all materilas, labour, transporation charges HOM of Equipmnts and testing complete as per specificatiosns | Ltr | 8.24 | 8.24 | 6000.0 | False | None | None | False | None | False | 49440.0 | 0 |
3122056 | 107231 | None | code152 | EXTERNAL WATER SUPPLY & SANITORY WORK Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 50mm dia., 6 kg/sqcm & class 5 | m | 104.03 | 104.03 | 110.0 | False | None | None | False | None | False | 11443.3 | 0 |
3122057 | 107231 | None | code153 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 FOR RAIN WATER PIPE | m | 423.33 | 423.33 | 110.0 | False | None | None | False | None | False | 46566.3 | 0 |
3122058 | 107231 | None | code154 | Providing and fixing Brass full way valve gate with C.I. wheel of
approved quality (screwed end) : 50 mm nominal bore | No | 880.65 | 880.65 | 4.0 | False | None | None | False | None | False | 3522.6 | 0 |
3122059 | 107231 | None | code155 | Providing and fixing Brass full way valve gate with C.I. wheel of
approved quality (screwed end) : 65 mm nominal bore | No | 1453.33 | 1453.33 | 6.0 | False | None | None | False | None | False | 8719.98 | 0 |
3122060 | 107231 | None | code156 | Constructing brick masonry chamber for underground C.I. inspection
chamber and bends with bricks in cement mortar 1:4 (1 cement : 4
coarse sand) C.I. cover with frame (light duty) 455x610 mm internal
dimensions, total weight of cover with frame to be not less than 38
kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab
with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20
mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand
: 10 graded stone aggregate 40 mm nominal size), inside plastering 12
mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished
smooth with a floating coat of neat cement on walls and bed concrete etc.
complete as per standard design: Inside dimensions 455x610 mm and
45 cm deep for single pipe line : With common burnt clay | Nos | 5811.26 | 5811.26 | 4.0 | False | None | None | False | None | False | 23245.04 | 0 |
3122061 | 107231 | None | code157 | Earth work excavation for Foundation by manual means for all Buildings,
Bridges, Retaining walls, Abutment Piers and such similar works
as per drawing and technical Specifications, including setting out, providing
shoring & strutting,barricading, caution lights, removal of stumps
and other deleterious matter, including dressing of excavated surfaces,
disposing off or levelling the excavated earth or sorting & stacking the
selected earth for reuse in a radius of 50 m and lift upto 1.5 m including
cost of labour, tools, usage& other appurtenances required to complete
the work.
Depth exceeding 1.5m, but not exceeding 3 m | Cum | 498.52 | 498.52 | 12.0 | False | None | None | False | None | False | 5982.24 | 0 |
3122062 | 107231 | None | code158 | Filling available excavated earth (excluding rock) in trenches, plinth,
sides of foundations and other similar works etc. in layers not exceeding
20cm in depth, consolidating each deposited layer by ramming and
watering, lead up to 50 m and lift upto 1.5 m. | Cum | 273.98 | 273.98 | 12.0 | False | None | None | False | None | False | 3287.76 | 0 |
3122063 | 107231 | None | code159 | Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-20003Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 3 HP 3.00 HP - 300 LPM at 26 m 5 STG Outlet Dia 2.50 | Each | 23863.04 | 23863.04 | 2.0 | False | None | None | False | None | False | 47726.08 | 0 |
3122064 | 107231 | None | code160 | borewell 1 numbers Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. | Each | 5295.23 | 5295.23 | 1.0 | False | None | None | False | None | False | 5295.23 | 0 |
3122065 | 107231 | None | code161 | Sinking of borewell of 165 mm dia clear using fast rig in all strata including over burden upto 30 M fixing of casing pipes, collars and cap with necessary cutting & threading including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes Upto 50 Mtrs | m | 357.41 | 357.41 | 50.0 | False | None | None | False | None | False | 17870.5 | 0 |
3122066 | 107231 | None | code162 | Sinking of borewell of 165 mm dia clear using fast rig in all strata including over burden upto 30 M fixing of casing pipes, collars and cap with necessary cutting & threading including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes Above 50 Mtrs and upto 100 Mtr. | m | 455.26 | 455.26 | 50.0 | False | None | None | False | None | False | 22763.0 | 0 |
3122067 | 107231 | None | code163 | Sinking of borewell of 165 mm dia clear using fast rig in all strata including over burden upto 30 M fixing of casing pipes, collars and cap with necessary cutting & threading including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes Above100 Mtrs. and upto 150 Mtr. | m | 469.68 | 469.68 | 50.0 | False | None | None | False | None | False | 23484.0 | 0 |
3122068 | 107231 | None | code164 | Sinking of borewell of 165 mm dia clear using fast rig in all strata including over burden upto 30 M fixing of casing pipes, collars and cap with necessary cutting & threading including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes Above150 Mtrs. and upto 200 Mtr. | m | 552.08 | 552.08 | 50.0 | False | None | None | False | None | False | 27604.0 | 0 |
3122069 | 107231 | None | code165 | Sinking of borewell of 165 mm dia clear using fast rig in all strata including over burden upto 30 M fixing of casing pipes, collars and cap with necessary cutting & threading including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes Above200 Mtrs. and upto 250 Mtr. | m | 653.02 | 653.02 | 50.0 | False | None | None | False | None | False | 32651.0 | 0 |
3122070 | 107231 | None | code166 | Sinking of borewell of 165 mm dia clear using fast rig in all strata including over burden upto 30 M fixing of casing pipes, collars and cap with necessary cutting & threading including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes Above200 Mtrs. and upto 300Mtr. | m | 721.0 | 721.0 | 50.0 | False | None | None | False | None | False | 36050.0 | 0 |
3122071 | 107231 | None | code167 | Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. | m | 1990.99 | 1990.99 | 35.0 | False | None | None | False | None | False | 69684.65 | 0 |
3122072 | 107231 | None | code168 | Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. Note: Upto 110mm dia Coil shall be used. For Grade PE80 PN6.0 : 63 mm dia | m | 197.37 | 197.37 | 300.0 | False | None | None | False | None | False | 59211.0 | 0 |
3122073 | 107231 | None | code169 | Supplying and deleviring at site submersible pumpset for 150 mm borewell and having the cleared duty conditions as detailed and satisfying the performance charecterstics for pump and motor as declared to the beureau of indian standards . The pumpset should bear the IS certificate mark ISI 8034 -1989 with amendment no.1 (with latest ammendment if any) etc., complete as per the direction of Engineer in charge 10.00 HP - 155 LPM @ 140 m = 10 STG Outlet Dia - 2.00” | Nos | 49705.74 | 49705.74 | 1.0 | False | None | None | False | None | False | 49705.74 | 0 |
3122074 | 107231 | None | code170 | Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments | Nos | 154.5 | 154.5 | 1.0 | False | None | None | False | None | False | 154.5 | 0 |
3122075 | 107231 | None | code171 | Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge | Nos | 168.92 | 168.92 | 1.0 | False | None | None | False | None | False | 168.92 | 0 |
3122076 | 107231 | None | code172 | Providing np cp 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) | Nos | 221.45 | 221.45 | 1.0 | False | None | None | False | None | False | 221.45 | 0 |
3122077 | 107231 | None | code173 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirmining to table 3 class 5 of IS8130 1984 and virgin grade PVC insulation and sheathed suitable for working voltage upto 1100Volts as per IS 6941990 & confirming to GTP of GROUP A 122.10 | Mtr | 172.01 | 172.01 | 163.92 | False | None | None | False | None | False | 28195.8792 | 0 |
3122078 | 107231 | None | code174 | Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete (49/6.40) 16SWG | Sq CM | 0.39 | 0.39 | 30000.0 | False | None | None | False | None | False | 11700.0 | 0 |
3122079 | 107231 | None | code175 | Supply and Installation I Fixing I Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase I Three Phase Energy Meter in suitable base plate and having a provision for Fuse I MCB cutout with suitable transparent hinged flap opening for operating MCB along with 10 complete tamper proof SEALING facility. (50/6.42) 600mmx600mmx170mm. | Each | 134.38 | 134.38 | 1.0 | False | None | None | False | None | False | 134.38 | 0 |
3122080 | 107231 | None | code176 | Supplying and fixing polished wood board made of not less than 15mm thick plank on both sides with planks made out of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws etc. - 500 x 500 x 65 mm (20" x 20" x 2.5") etc., complete as per directions of the Engineer-in-charge | Each | 324.45 | 324.45 | 1.0 | False | None | None | False | None | False | 324.45 | 0 |
3122081 | 107231 | None | code177 | Supplying and fixing miniature circuit breakers/Isolators on existing MCB distribution boards using necessary fixing materials and wiring complete as directed by the Engineer-in-charge - 5 to 30 Amps Triple and Neutral | Each | 1593.41 | 1593.41 | 1.0 | False | None | None | False | None | False | 1593.41 | 0 |
3122082 | 107231 | None | code178 | Supplying and fixing TPST with neutral link switches rewirable fuse type - Havels / Standard / Indo-Asian Crescent - 30 to 35 Amps, etc., complete as per directions of the Engineer-in-charge | Each | 2002.32 | 2002.32 | 1.0 | False | None | None | False | None | False | 2002.32 | 0 |
3122083 | 107231 | None | code179 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery (48/6.35) | Each | 444.96 | 444.96 | 1.0 | False | None | None | False | None | False | 444.96 | 0 |
3122084 | 107231 | None | code180 | SUMP TANK Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m consider hard soil 70% of total excavation qty | Cum | 105.06 | 105.06 | 22.3 | False | None | None | False | None | False | 2342.838 | 0 |
3122085 | 107231 | None | code181 | In ordinary/soft rock without blasting, Depth exceeding 1.5 m, but not exceeding 3 m consider 20% of total excavation qty | Cum | 373.89 | 373.89 | 6.37 | False | None | None | False | None | False | 2381.6793 | 0 |
3122086 | 107231 | None | code182 | Earth work excavation for FOUNDATION by Mechanical means depth
upto 1.50m, as per drawing and technical specifications, including
setting out, shoring, strutting, barricading, caution lights, including cost
of explosives, dressing of excavated surfaces, disposing off or levelling
the excavated stuff or sorting & stacking the selected stuff for reuse
in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting
materials, tools, usage of Machinery & all other appurtenaces required
to complete the work consider 10% of total excavation qty | Cum | 570.62 | 570.62 | 3.19 | False | None | None | False | None | False | 1820.2778 | 0 |
3122087 | 107231 | None | code183 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 273.98 | 273.98 | 8.78 | False | None | None | False | None | False | 2405.5444 | 0 |
3122088 | 107231 | None | code184 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 121.54 | 121.54 | 12.25 | False | None | None | False | None | False | 1488.865 | 0 |
3122089 | 107231 | None | code185 | Providing and laying in position plain cement concrete for levelling
course for all works in foundation. The granite/trap/basalt crushed
graded coarse aggregates and fine aggregates as per relevant IS
Codes machine mixed, laid in layers not exceeding 150 mm thickness,
well compacted using plate vibrators, including all lead & lifts, cost of
all materials of quality, labour, Usage charges of machineries, curing,
and all the other appurtenances required to complete the work as per
technical specifications. (The cost of steel reinforcement & formwork
shall be paid separately)
Mix 1:3:6 (M10) Using 40 mm and down size graded crushed coarse
aggregates | Cum | 6168.67 | 6168.67 | 1.73 | False | None | None | False | None | False | 10671.7991 | 0 |
3122090 | 107231 | None | code186 | Providing and laying in position Reinforced cement concrete for all
Foundation works. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine
mixed with super plasticizers laid in finished layers, well compacted
using needle vibrators, including all lead & lifts, cost of all materials,
quality confirming to the requirements of relevant IS codes , labour,
Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications. (The cost
of steel reinforcement & formwork to be paid separately)
M25 Design Mix Using 20 mm and down size graded crushed coarse
aggregates consider 8% of finished rate of concrete for foundation upto plitnth shuttering | Cum | 7048.17 | 7048.17 | 13.92 | False | None | None | False | None | False | 98110.5264 | 0 |
3122091 | 107231 | None | code187 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | t | 92140.71 | 92140.71 | 2.68 | False | None | None | False | None | False | 246937.1028 | 0 |
3122092 | 107231 | None | code188 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3
coarse sand) finished with a floating coat of neat cement on the rough
side of single or half brick wall including rounding off corners wherever
required smooth rendering, providing and removing scaffolding,
including cost of materials, labour, curing complete as per specifications
and as per directions of Engineer-in-charge. | Sqm | 376.98 | 376.98 | 111.6 | False | None | None | False | None | False | 42070.968 | 0 |
3122093 | 107231 | None | code189 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 841.51 | 841.51 | 77.58 | False | None | None | False | None | False | 65284.3458 | 0 |
3122094 | 107231 | None | code190 | ELEVATION WORKS Providing and fixing of Aluminium composite panel of approved make
and colour for wall cladding for Brick/Rcc/stone walls & coloumns/
beams with necessary aluminium frame works at required level made
out of 50x25x4mm C section or equivalent. The panel should consist
of 3mm thick non-halogenated FR grade mineral based polymer ( 2
hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per
ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet
making a total panel thickness of 4mm. The surfaces will be finished
with PVDF based coating on topsides and service coating on reverse
sides would be in polyester paint. The system shall be fixed using GI
brackets, aluminium L cleats and stainless steel bolts and nuts complete
with spring washer and cap nuts and all other necessary accessories,
sealing shall be done with necessary rods etc., complete acp | Sqm | 4108.67 | 4108.67 | 60.0 | False | None | None | False | None | False | 246520.2 | 0 |
3122095 | 107231 | None | code191 | ELEVATION WORKS Providing and fixing of Aluminium composite panel of approved make
and colour for wall cladding for Brick/Rcc/stone walls & coloumns/
beams with necessary aluminium frame works at required level made
out of 50x25x4mm C section or equivalent. The panel should consist
of 3mm thick non-halogenated FR grade mineral based polymer ( 2
hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per
ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet
making a total panel thickness of 4mm. The surfaces will be finished
with PVDF based coating on topsides and service coating on reverse
sides would be in polyester paint. The system shall be fixed using GI
brackets, aluminium L cleats and stainless steel bolts and nuts complete
with spring washer and cap nuts and all other necessary accessories,
sealing shall be done with necessary rods etc., complete acp | Sqm | 4149.76 | 4149.76 | 60.0 | False | None | None | False | None | False | 248985.6 | 0 |
3122096 | 107231 | None | code192 | Providing and fixing 20mm thick gang saw water cut Lakared granite
for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a
coat of rough plastering using CM 1:4 (1 cement : 4 fine sand), cut to
required shape, pattern with paper joints, finished with cement mortar
using white cement and colour pigments to match the colour of slab
making through jointing with sealant, grooves in joints including cost of
curing etc., complete including cost and conveyance of all materials,
mortar, labour for all items of work, usage charges of machinery etc.,
complete as per specification. granite cladding | Sqm | 3715.21 | 3715.21 | 67.5 | False | None | None | False | None | False | 250776.675 | 0 |
3122097 | 107231 | None | code193 | Providing and fixing 20mm thick gang saw water cut Lakared granite
for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a
coat of rough plastering using CM 1:4 (1 cement : 4 fine sand), cut to
required shape, pattern with paper joints, finished with cement mortar
using white cement and colour pigments to match the colour of slab
making through jointing with sealant, grooves in joints including cost of
curing etc., complete including cost and conveyance of all materials,
mortar, labour for all items of work, usage charges of machinery etc.,
complete as per specification. granite cladding | Sqm | 3752.36 | 3752.36 | 67.5 | False | None | None | False | None | False | 253284.3 | 0 |
3122098 | 107231 | None | code194 | Providing and fixing of Laterite cladding tiles of size 230x75x10mm thick
on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) & jointed
with Adhesive over rough plaster surface excluding cost of rough plastered
surface. The work includes cost of all materials, labour charges
for all items of work, usage charges for equipment, etc., complete as
per specification. granite cladding | Sqm | 2243.34 | 2243.34 | 60.0 | False | None | None | False | None | False | 134600.4 | 0 |
3122099 | 107231 | None | code195 | Providing and fixing of Laterite cladding tiles of size 230x75x10mm thick
on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) & jointed
with Adhesive over rough plaster surface excluding cost of rough plastered
surface. The work includes cost of all materials, labour charges
for all items of work, usage charges for equipment, etc., complete as
per specification. granite cladding | Sqm | 2265.77 | 2265.77 | 60.0 | False | None | None | False | None | False | 135946.2 | 0 |
3122100 | 107231 | None | code196 | NON SR ITEMS : Providing and fixing Alluminium fixtures like 1 no of Aldrops of size 300 x 16 mm, 2 no's of Tower bolts of size 200 x 12 mm, 100 mm length ss Hinges, 2nos of Handles of size 200 mm, 1 no of Door Stopper & 1 no of Door Bush of approved make and quality including cost and conveyance of all materials and as per the direction of EIC of work with all lead and lift and as directed by the Engineer in charge of works. | Nos | 807.7 | 807.7 | 25.0 | False | None | None | False | None | False | 20192.5 | 0 |
3122101 | 107231 | None | code197 | Forming horizontal or vertical grooves on uniform size 10 mm wide and 7 mm deep at junction of wall and column / beam and finishing the grooves to elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. | m | 25.42 | 25.42 | 1820.0 | False | None | None | False | None | False | 46264.4 | 0 |
3122102 | 107231 | None | code198 | Supplying, fixing, testing and commissioning of 15mm dia CP Long body Bib Cock (wall mounted model) for wash area with CP wall flange etc. | Nos | 738.0 | 738.0 | 12.0 | False | None | None | False | None | False | 8856.0 | 0 |
3122103 | 107231 | None | code199 | Supplying and fixing of Robe hook Fixed on the toilet Door as directed by the Engineer in charge. | Nos | 525.62 | 525.62 | 20.0 | False | None | None | False | None | False | 10512.4 | 0 |
3122104 | 107231 | None | code200 | Providing, fixing, testing and commissioning of PVC gullytrap of 150 x 150 mm size with 100 mm dia outlet making excavation pit in all kinds of soil and laying of 100 mm thick 1:4:8 mix cement concrete bed and constructing chamber with internal clear dimension of 300 x 300 mm using table moulded wire cut bricks in brick work 115 mm thick in cement mortar 1:4 up to a height of 300 mm above gully trap or up to 100 mm above paving level, plastering internal and external surface with cement mortar 1:4 to 15m thick finishing to smooth inside surface with necessary benching and channelling providing 150 x 150 mm size cast iron grating, including 40 mm thick precast RCC cover slab, clearing the surplus material, earth etc. complete as per drawing. 150mm x 150mm size 'P/S' trap | Nos | 3690.0 | 3690.0 | 12.0 | False | None | None | False | None | False | 44280.0 | 0 |
3122105 | 107231 | None | code201 | Providing & fixing of CP waste coupling 32mm Size full thread for Truf | Each | 369.0 | 369.0 | 14.0 | False | None | None | False | None | False | 5166.0 | 0 |
3122106 | 107231 | None | code202 | Providing, fixing, testing and commissioning of deep seal PVC multi inlet floor trap of self cleansing design moulded or fabricated with CP grating, rubber ring / solvent cement followed by application of leak proof adhesive like FRP paste including making good the floors etc., complete as directed by the Engineer in charge. | Each | 258.3 | 258.3 | 12.0 | False | None | None | False | None | False | 3099.6 | 0 |
3122107 | 107231 | None | code203 | Supplying , installing, testing and commissioning of brass body nickel plated automatic air release valves with brass splindle, NBR and joinfraniteelastomer,staniless steel spring polypropylenic float at the top most points of watersupply distribution ringmain. | Each | 1125.04 | 1125.04 | 25.0 | False | None | None | False | None | False | 28126.0 | 0 |
3122108 | 107231 | None | code204 | Construction of percolation well / rain water harvest pit of 2 m dia and 3m deep with precast RCC rings, covering the top with RCC slab including supply and fixing 600 x 600 RCC MH cover CI / MS rungs etc. The quoted rate shall include earth work excavation, back filling, removing excess earth and making good the floor. The percolation well harvest pit shall be constructed as per the detail drawings and specification shall consists of: Alternate layers of brick bats, activated charcoal, gravel, pebbles and toped with fine sand for good infiltration. 3 Nos. bore holes of 160 mm dia from the bottom of percolation pit for a depth of 6m, drilled by using auger manually. Bore hole to be filled with medium sized pebbles to provide mechanical strength to the holes and enhance infiltration.Rate quoted shall be inclusive of earth work excavation, back filling, removing of excess earth as per the instructions of engineer - in charge. | Each | 22960.0 | 22960.0 | 1.0 | False | None | None | False | None | False | 22960.0 | 0 |
3122109 | 107231 | None | code205 | FURNITURE MEETING HALL TABLEDimension: (7200mm x 800mm x 750mm) + (7200mm x 800m x 750mm) (U-Shaped)Providing and FabricFURNITURE WORKS ating U-Shaped Board room Table with 19mm ply Finished with 4mm thk Approved Veneer Melamine finished. Table top: 40mm thick table top to be formed out 2 layers of 19mm tk ply and to be finished with 4mm thk approved Veneer and melamine polished. The edge of the table to be provided with approved timber beading to form 50mm thick fascia formed to shape finished with approved Melamine polish to match the veneer. The top to house cable trough / cable pop up box for cable management with 19mm thk ply openable as per details, complete as per detail dwg.Base: The base of the table shall consist of 19mm commercial ply finished with 4mm thk veneer of approved make & shade. Cost to include providing & fixing 6x6mm thk Aluminium beading, complete as per the drawing and instructions of the Engineer-in-charge. | Nos | 198615.48 | 198615.48 | 1.0 | False | None | None | False | None | False | 198615.48 | 0 |
3122110 | 107231 | None | code206 | STORAGE: Providing and fixing storage unit of 0.45m depth made out of 19mm thick commercial ply vertical support finished in approved 1.5mm laminate with 12mm thick ply backing internally finished with enamel paint of approved colour and shade shelves shall be formed out of 19mm ply finished with enamel paint of approved shade and colour and 19mm thick shutters formed out of 19mm thick ply finished with 1.5mm thick laminate of approved shade and colour etc., complete the rate includes cost of all materials, labour charges, complete as per specifications & instructions of the Engineer-in-charge.Mode of measurement : Length & height of the storage shall be measured for payment. | Nos | 7482.5 | 7482.5 | 12.0 | False | None | None | False | None | False | 89790.0 | 0 |
3122111 | 107231 | None | code207 | RECEPTION TABLE:Table Dimension: (3000 x 600 x 750mm) + Transaction counter (1500mm x 250mm x 1050mm):
Providing and Fabricating Reception Table with storage, formed with 19mm ply Finished with 4mm thk Approved Veneer Melamine finished. Table top: 40mm thick table top to be formed out 2 layers of 19mm tk ply and to be finished with 4mm thk approved Veneer and melamine polished. The edge of the table to be provided with approved timber beading to form 50mm thick fascia formed to shape Finished with approved Melamine polish to match the veneer. The top to house cable trough / cable pop up box for cable management with 19mm thk ply openable as per details, complete as per detail dwg. Base: The base of the table shall consist of 19mm commercial ply boxing finished with 4mm thk veneer of approved make & shade. Cost to include providing & fixing 6x6mm thk Aluminium beading, complete as per the drawing & instructions of the Engineer-in-charge.
Storage: Storage partitions to be formed out of 19mm thick ply to required shape & size finished with 1.5mm thick laminate on internal surfaces. Store drawers to be provided with approved size of handles, locking arrangements etc., complete as per details drawings & instructions of the Engineer-in-charge. | Nos | 41580.56 | 41580.56 | 1.0 | False | None | None | False | None | False | 41580.56 | 0 |
3122112 | 107231 | None | code208 | CONFERENCE ROOM - PANEL TABLE Table Dimension: 5600mm x 750mm x 750mmProviding and Fabricating Conference Table with 19mm ply Finished with 4mm thk Approved Veneer Melamine finished. Table top: 40mm thick table top to be formed out 2 layers of 19mm tk ply and to be finished with 4mm thk approved Veneer and melamine polished. The edge of the table to be provided with approved timber beading to form 50mm thick fascia formed to shape finished with approved Melamine polish to match the veneer. The top to house cable trough / cable pop up box for cable management with 19mm thk ply openable as per details, complete as per detail dwg.Base: The base of the table shall consist of 19mm commercial ply finished with 4mm thk veneer of approved make & shade over sal wood-50x50mm frame work. Cost to include providing & fixing 6x6mm thk Aluminium beading, complete as per the drawing and instructions of the Engineer-in-charge. | Nos | 54334.84 | 54334.84 | 1.0 | False | None | None | False | None | False | 54334.84 | 0 |
3122113 | 107231 | None | code209 | CABIN TABLES - TYPE-1:Table Dimension: (3500 x 900 x 750mm) + (1350mm x 800mm x 750mm) L shaped : Providing and Fabricating Cabin Table with 19mm ply Finished with 4mm thk Approved Veneer Melamine finished. Table top: 40mm thick table top to be formed out 2 layers of 19mm tk ply and to be finished with 4mm thk approved Veneer and melamine polished. The edge of the table to be provided with approved timber beading to form 50mm thick fascia formed to shape Finished with approved Melamine polish to match the veneer. The top to house cable trough / cable pop up box for cable management with 19mm thk ply openable as per details, complete as per detail dwg.Base: The base of the table shall consist of 19mm commercial ply boxing finished with 4mm thk veneer of approved make & shade. Cost to include providing & fixing 6x6mm thk Aluminium beading, complete as per the drawing & instructions of the Engineer-in-charge. | Nos | 60862.86 | 60862.86 | 1.0 | False | None | None | False | None | False | 60862.86 | 0 |
3122114 | 107231 | None | code210 | CABIN TABLES - TYPE-2:Table Dimension: 1800mm x 750mm x 750mm: Providing and Fabricating Cabin Table with 19mm ply Finished with 4mmthk Approved Veneer Melamine finished.
Table top: 19mm thick table top to be formed out of 19mm tk ply and to be finished with 4mm thk approved Veneer and melamine polished. The edge of the table to be provided with approved timber beading to form 30mm thick fascia formed to shape Finished with approved Melamine polish to match the veneer. The top to house cable trough / cable pop up box for cable management with 19mm thk ply openable as per details, complete as per detail dwg. Base: The base of the table shall consist of 19mm commercial ply finished with 4mm thk veneer of approved make & shade. complete as per the drawing & instructions of the Engineer-in-charge. | Nos | 16703.4 | 16703.4 | 10.0 | False | None | None | False | None | False | 167034.0 | 0 |
3122115 | 107231 | None | code211 | BACK STORAGE (Length between 1100 to 1800mm) x 600mm depth x 750mm height: Back Storage: Providing & fabricating storage formed out of 19mm thick ply & finished with 4mm thk approved Veneer and melamine polished. The storage shall consists of shutters & shelves in 19mm thk ply & finished with 1.5mm thk approved laminate on both sides. The shutters shall be mounted over spring loaded auto closing hinges of approved make, tower bolt. The exposed edges of the storage shall be lipped using approved edge binding, complete as per detail dwg. & instructions of the Engineer-in-charge.Mode of Measurement : Length & Height of the storage shall be measure for payment. | Nos | 17494.7 | 17494.7 | 12.0 | False | None | None | False | None | False | 209936.4 | 0 |
3122116 | 107231 | None | code212 | BACK STORAGE - (Length between 5770 to 7270mm) x 600mm depth x 750mm heightBack Storage: Providing & fabricating storage formed out of 19mm thick ply & finished with 4mm thk approved Veneer and melamine polished. The storage shall consists of shutters & shelves in 19mm thk ply & finished with 1.5mm thk approved laminate on both sides. The shutters shall be mounted over spring loaded auto closing hinges of approved make, tower bolt. The exposed edges of the storage shall be lipped using approved edge binding, complete as per detail dwg. & instructions of the Engineer-in-charge.Mode of Measurement : Length & Height of the storage shall be measure for payment. | Nos | 16467.24 | 16467.24 | 1.0 | False | None | None | False | None | False | 16467.24 | 0 |
3122117 | 107231 | None | code213 | HIGH BACK CHAIR - Leatherette with head rest with castors: Supplying & placing in position High back chair with following specification. Seat: Seat to be formed out of bent ply / PVC backing with deformable pre moulded foam upholstered with approved fabric. Back rest: The high back rest in leatherette over frame. The back rest to have provision of height adjustable backrest for an optimum adjustment of the lumbar support, to be either by turning knob or push- button. upholstered with Leatherette. High back chair to have head rest. Mechanism: Synchronised knee-tilt with 2 way locking mechanism. Gas lift: synchronised gas lift. Arm rest: Adjustable arm rest to be formed out of PU foam / PVC with fixed arm. Base: Base shall consist of 5 prong formed of die cast aluminium with chrome plated finish with soft-dual wheel castors. Castors: Twin wheel high resistant polyamide castors. | Nos | 8778.92 | 8778.92 | 14.0 | False | None | None | False | None | False | 122904.88 | 0 |
3122118 | 107231 | None | code214 | MEDIUM BACK CHAIR- FABRIC without castors:
Supplying & placing in position medium back chair with following specification. Seat: Seat to be formed out of bent ply / PVC backing with deformable pre moulded foam upholstered with approved fabric. Back rest: The medium back rest in fabric over frame. The back rest to have provision of height adjustable backrest for an optimum adjustment of the lumbar support, to be either by turning knob or push- button. upholstered with Mesh fabric. Mechanism: Synchronised knee-tilt with 2 way locking mechanism. Gas lift: synchronised gas lift. Arm rest: Fixed arm rest to be formed out of PU foam / PVC with provision of height swinging adjustment, Width adjustment, height adjustments. Base: Base shall consist of 5 prong formed of Nylon legs. | Nos | 7030.68 | 7030.68 | 70.0 | False | None | None | False | None | False | 492147.6 | 0 |
3122119 | 107231 | None | code215 | DOUBLE SEATER SOFA: Providing & fabricating DOUBLE SEATER SOFA in silver wood frame work with 150mm thick foam backing for seat & back rest clad with two layers of 12mm thick foam of approved make clad with 2mm thick foam finished in approved leatherette. The sofa to be provided with 50mm ht. SS legs complete as per detail dwg & instructions of the Engineer-in-charge. | Nos | 22026.02 | 22026.02 | 1.0 | False | None | None | False | None | False | 22026.02 | 0 |
3122120 | 107231 | None | code216 | THREE SEATER SOFA: Providing & fabricating THREE SEATER SOFA in silver wood frame work with 150mm thick foam backing for seat & back rest clad with two layers of 12mm thick foam of approved make clad with 2mm thick foam finished in approved leatherette. The sofa to be provided with 50mm ht. SS legs complete as per detail dwg & instructions of the Engineer-in-charge. | Nos | 30575.34 | 30575.34 | 9.0 | False | None | None | False | None | False | 275178.06 | 0 |
3122121 | 107231 | None | code217 | SIDE TABLE: Providing & fabricating centre table of size 500mm X 500mm formed out of 19mm thick commercial ply finished in 4mm thick approved veneer with edge lipping finished in melamine polished. The base shall be formed out of 16mm dia. Brushed finish SS pipe, complete as per detail dwg & instructions of the Engineer-in-charge. | Nos | 9367.68 | 9367.68 | 5.0 | False | None | None | False | None | False | 46838.4 | 0 |
3122122 | 107231 | None | code218 | Perforated Acoustic Woodworks Wall Panel
(AP 01) : Providing & Fixing of
Woodworks Wall Panel System having Square
edge Panels with Z-Clip mounting system. The
Panels to be made of a Moisture resistant fibre board with minimum 595 Kg/M3 density
substrate. The panels shall have size of 600mm
W x 600mm L, having Round R3 perforations
having hole diameter as 3mm with laminate
shade as approved by the Architect or Engineerin-
Charge, with 0.7mm matching PVC edge
banding. Back side of the tile will have Soundtex
fleece hot pressed to achieve NRC of 0.55,
Humidity Resistance (RH) of 70%.The panels
having Z-Clips (made of Aluminum extruded
sections) fixed at the back, shall be mounted on
Z-Strips (made of Aluminum extruded sections)
in accordance to the shop drawings.
INSTALLATION: The Z-Strips shall be secured
to the walls using appropriate fasteners as per the
locations and dimensions indicated in the shop
drawings. All panels intended for Z-clips shall be
with nokerfs in any of the edges. The Panels shall
be mounted on the Z-strips such that Z-clips
shall have positive engagement with the Z-strips.
A 5mm reveal (5mm foam gasket) to be
maintained between every two panels. (Non SR)
(Auditorium Main Hall) | Sqm | 5453.0 | 5453.0 | 126.0 | False | None | None | False | None | False | 687078.0 | 0 |
3122123 | 107231 | None | code219 | CAMERAS & ACCESSORIES: Supply, erection, testing & commissioning 2 Megapixel high-performance CMOS, Analog HD output, up to 1080P resolution, True Day/Night, True WDR, up to 120dB,EXIR technology, up to 20m IR distance , IP66 weatherproof ,Max. 5W, with 4*4 Model Box for Camera and other accessories. | Nos | 4524.76 | 4524.76 | 6.0 | False | None | None | False | None | False | 27148.56 | 0 |
3122124 | 107231 | None | code220 | Supply, erection, testing & commissioning of 12/24V, 4 out put Camera Power Supply (SMPS, switched-mode power supply) Each Camera have Separate Terminal, including all Accessories. | Nos | 1256.24 | 1256.24 | 6.0 | False | None | None | False | None | False | 7537.44 | 0 |
3122125 | 107231 | None | code221 | Supply, erection, testing & commissioning of High resolution 16 channel Supply, erection, testing & commissioning of High resolution 16 channel with following configuration. High performance Triple Platform HD TVI DVR, with H.264 Compression (High Profile)
Max 1080p HD resolution supported
HD TVI, Analog and IP cameras supported; Supports ONVIF Under NVR Mode HDD 1 HDDs upto 4TB supported
Audio Input output 1 In 1 Out
Video Outputs 1 x HDMI, 1 x VGA
Network Port 1 x Gigabit (10 100 1000) adaptive network port
Multi Input modes Analog (16 x 720p HD TV 16 x 960H) Network (2 x 720P/ 960P/ 1080P), 2 TB Sata Surveillance HDD storage capacity. | Nos | 42856.48 | 42856.48 | 1.0 | False | None | None | False | None | False | 42856.48 | 0 |
3122126 | 107231 | None | code222 | Supply, Installation, Testing & Commissioning of 24inch LED Monitor with all accessories. | Nos | 14076.12 | 14076.12 | 1.0 | False | None | None | False | None | False | 14076.12 | 0 |
3122127 | 107231 | None | code223 | Supply and laying of 3+1 Camera Cable with power and co axial (Pure Copper) in Existing 25mm Dia PVC conduits with all necessary accessories. | m | 34.44 | 34.44 | 210.0 | False | None | None | False | None | False | 7232.4 | 0 |
3122128 | 107231 | None | code224 | Supply and Termination of above cable by using BNC connector and DC pin with all accessories. | m | 185.32 | 185.32 | 102.0 | False | None | None | False | None | False | 18902.64 | 0 |
3122129 | 107231 | None | code225 | Supply and fixing of Krone type tag block with lock & key enclosed in a MS. box of cable terminations.5 Pair | Nos | 401.8 | 401.8 | 8.0 | False | None | None | False | None | False | 3214.4 | 0 |
3122130 | 107231 | None | code226 | Supply and fixing of Krone type tag block with lock & key enclosed in a MS. box of cable terminations.20 Pair | Nos | 1105.36 | 1105.36 | 4.0 | False | None | None | False | None | False | 4421.44 | 0 |
3122131 | 107231 | None | code227 | Supply and Installation of EPABX for Intercom system for 1 No. Direct lines, 1No. STD Line, 24Nos. Extension Lines, with other standard specification. | Nos | 25138.74 | 25138.74 | 1.0 | False | None | None | False | None | False | 25138.74 | 0 |
3122132 | 107231 | None | code228 | PROJECTORS AND SCREEN SUITABLE:
Supplying, installation, testing, commissioning 2000 lumens, WXGA Resolution Multimedia Projector, the projectors 1920x1080 and should support all relevant WXGA variants. They should additionally support other relevant resolutions, like VGA, XGA and SXGA. The projectors should at a minimum support HDTV at 720p. It should be possible to connect a laptop with the above-mentioned video formats, and choose between various sources without having to make changes in the setup menu for the projectors. Switching between sources with 4:3 formats and widescreen formats should be automatically managed with the correct aspect ratio. If necessary, a scaler should be included in order to satisfy the above-mentioned requirements. | Nos | 183011.7 | 183011.7 | 1.0 | False | None | None | False | None | False | 183011.7 | 0 |
3122133 | 107231 | None | code229 | Supply, laying and installation of HDMI Cables including Termination and all necessary accessories. | m | 220.58 | 220.58 | 60.0 | False | None | None | False | None | False | 13234.8 | 0 |
3122134 | 107231 | None | code230 | Supply, laying and installation of RGB Cables including Termination and all necessary accessories. | m | 182.86 | 182.86 | 45.0 | False | None | None | False | None | False | 8228.7 | 0 |
3122135 | 107231 | None | code231 | Supply, laying and installation of VGA Cables including Termination and all necessary accessories. | m | 326.36 | 326.36 | 25.0 | False | None | None | False | None | False | 8159.0 | 0 |
3122136 | 107231 | None | code232 | Supply & Fixing of Table top Flip tops comprising of 1 No. Data, 1 No. Telephone outlet & 2x6A Socket controlled by 6A Switch, including all necessary accessories. | No | 7541.54 | 7541.54 | 20.0 | False | None | None | False | None | False | 150830.8 | 0 |
3122137 | 107231 | None | code233 | Internal Electrification Open Conduit System Supplying heavy gauge PVC conduit pipe……mm dia ......mm thick conforming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc.,and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 32 mm dia 2.5mm thick | Mtr | 106.0 | 106.0 | 150.0 | False | None | None | False | None | False | 15900.0 | 0 |
3122138 | 107231 | None | code234 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe……mm dia ......mm thick conforming to IS 2509 with suitable size bends,metal/PVC junction boxes,adhesive paste etc.,and running before slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18 SWG GI fish wire wherever necessary. 25 mm dia 2mm thick | Mtr | 78.0 | 78.0 | 350.0 | False | None | None | False | None | False | 27300.0 | 0 |
3122139 | 107231 | None | code235 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe……mm dia ......mm thick conforming to IS 2509 with suitable size bends,metal/PVC junction boxes,adhesive paste etc.,and running before slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18 SWG GI fish wire wherever necessary. 20 mm dia 2mm thick | Mtr | 66.0 | 66.0 | 340.0 | False | None | None | False | None | False | 22440.0 | 0 |
3122140 | 107231 | None | code236 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe……mm dia ......mm thick conforming to IS 2509 with suitable size bends,metal/PVC junction boxes,adhesive paste etc.,and running before slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18 SWG GI fish wire wherever necessary. 32 mm dia 2.5mm thick | Mtr | 103.0 | 103.0 | 150.0 | False | None | None | False | None | False | 15450.0 | 0 |
3122141 | 107231 | None | code237 | Supplying heavy gauge PVC conduit pipe……mm dia ......mm thick with suitable size bends,metal junction boxes,adhesive paste etc.,by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25 mm dia 2mm thick | Mtr | 79.0 | 79.0 | 350.0 | False | None | None | False | None | False | 27650.0 | 0 |
3122142 | 107231 | None | code238 | Supplying heavy gauge PVC conduit pipe……mm dia ......mm thick with suitable size bends,metal junction boxes,adhesive paste etc.,by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 20 mm dia 2mm thick | Mtr | 68.0 | 68.0 | 150.0 | False | None | None | False | None | False | 10200.0 | 0 |
3122143 | 107231 | None | code239 | Supplying and flush mounting powder coated / galvanised metal box suitable for mounting modular witch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/CC wall. 1-3 Way | Each | 138.0 | 138.0 | 70.0 | False | None | None | False | None | False | 9660.0 | 0 |
3122144 | 107231 | None | code240 | Supplying and flush mounting powder coated / galvanised metal box suitable for mounting modular witch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/CC wall. 4-5 Way | Each | 177.0 | 177.0 | 45.0 | False | None | None | False | None | False | 7965.0 | 0 |
3122145 | 107231 | None | code241 | Supplying and flush mounting powder coated / galvanised metal box suitable for mounting modular witch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/CC wall. 6 Way | Each | 220.0 | 220.0 | 45.0 | False | None | None | False | None | False | 9900.0 | 0 |
3122146 | 107231 | None | code242 | Supplying and flush mounting powder coated / galvanised metal box suitable for mounting modular witch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/CC wall. 8 Way | Each | 261.0 | 261.0 | 50.0 | False | None | None | False | None | False | 13050.0 | 0 |
3122147 | 107231 | None | code243 | Supplying and flush mounting powder coated / galvanised metal box suitable for mounting modular witch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/CC wall. 12 Way | Each | 319.0 | 319.0 | 20.0 | False | None | None | False | None | False | 6380.0 | 0 |
3122148 | 107231 | None | code244 | Supplying and fixing superior quality modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1-3 Way | Each | 161.0 | 161.0 | 65.0 | False | None | None | False | None | False | 10465.0 | 0 |
3122149 | 107231 | None | code245 | Supplying and fixing superior quality modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Way | Each | 175.0 | 175.0 | 65.0 | False | None | None | False | None | False | 11375.0 | 0 |
3122150 | 107231 | None | code246 | Supplying and fixing superior quality modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Way | Each | 234.0 | 234.0 | 70.0 | False | None | None | False | None | False | 16380.0 | 0 |
3122151 | 107231 | None | code247 | Supplying and fixing superior quality modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Way | Each | 284.0 | 284.0 | 30.0 | False | None | None | False | None | False | 8520.0 | 0 |
3122152 | 107231 | None | code248 | Supplying and fixing superior quality modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 12 Way | Each | 344.0 | 344.0 | 25.0 | False | None | None | False | None | False | 8600.0 | 0 |
3122153 | 107231 | None | code249 | Supplying 4 mm thick plastic sheet with necessary nitches for fixing switches regulators etc, and fixing on existing wooden / metal box using N.F screws. | Sq CM | 0.41 | 0.41 | 12000.0 | False | None | None | False | None | False | 4920.0 | 0 |
3122154 | 107231 | None | code250 | Point wiring using Copper wire without switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS
multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the
other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3 Mtr from the tapping point to outlet via switch box. | Each | 269.0 | 269.0 | 10.0 | False | None | None | False | None | False | 2690.0 | 0 |
3122155 | 107231 | None | code251 | Point wiring using Copper wire without switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS
multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the
other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3 Mtr upto 6 mtr from tapping point to outlet via switch box. | Each | 379.0 | 379.0 | 10.0 | False | None | None | False | None | False | 3790.0 | 0 |
3122156 | 107231 | None | code252 | Point wiring using Copper wire without switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS
multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the
other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6 Mtr upto 10 Mtr. tapping point from outlet via switch box. | Each | 555.0 | 555.0 | 25.0 | False | None | None | False | None | False | 13875.0 | 0 |
3122157 | 107231 | None | code253 | Point wiring using Copper wire without switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS
multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the
other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two out let in a row, above 3 meter upto 6 meter from tapping point to outlet via switch | Each | 677.0 | 677.0 | 10.0 | False | None | None | False | None | False | 6770.0 | 0 |
3122158 | 107231 | None | code254 | Point wiring using Copper wire without switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS
multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the
other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three out let in a row, above 6 meter upto 10 meter from tapping point to outlet via switch | Each | 989.0 | 989.0 | 20.0 | False | None | None | False | None | False | 19780.0 | 0 |
3122159 | 107231 | None | code255 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multi-strand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & cofirming to latest amendments. 1.5 sqmm | Mtr | 26.0 | 26.0 | 1000.0 | False | None | None | False | None | False | 26000.0 | 0 |
3122160 | 107231 | None | code256 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multi-strand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & cofirming to latest amendments. 2.5 sqmm | Mtr | 42.0 | 42.0 | 1375.0 | False | None | None | False | None | False | 57750.0 | 0 |
3122161 | 107231 | None | code257 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multi-strand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & cofirming to latest amendments. 4 sqmm | Mtr | 63.0 | 63.0 | 446.46 | False | None | None | False | None | False | 28126.98 | 0 |
3122162 | 107231 | None | code258 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multi-strand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & cofirming to latest amendments. 6 sqmm | Mtr | 92.0 | 92.0 | 80.0 | False | None | None | False | None | False | 7360.0 | 0 |
3122163 | 107231 | None | code259 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multi-strand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & cofirming to latest amendments. 10 sqmm | Mtr | 167.0 | 167.0 | 200.0 | False | None | None | False | None | False | 33400.0 | 0 |
3122164 | 107231 | None | code260 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multi-strand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & cofirming to latest amendments. 16 sqmm | Mtr | 318.0 | 318.0 | 140.0 | False | None | None | False | None | False | 44520.0 | 0 |
3122165 | 107231 | None | code261 | Modular Switches, Sockets, Fan Regulators, TV/Telephone sockets with Networking&Telecommunications Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6 Amps One Way switch | Each | 102.0 | 102.0 | 450.0 | False | None | None | False | None | False | 45900.0 | 0 |
3122166 | 107231 | None | code262 | Modular Switches, Sockets, Fan Regulators, TV/Telephone sockets with Networking&Telecommunications Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6 Amps Two Way switch | Each | 166.0 | 166.0 | 6.0 | False | None | None | False | None | False | 996.0 | 0 |
3122167 | 107231 | None | code263 | Modular Switches, Sockets, Fan Regulators, TV/Telephone sockets with Networking&Telecommunications Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6 Amps 3 Way socket | Each | 171.0 | 171.0 | 250.0 | False | None | None | False | None | False | 42750.0 | 0 |
3122168 | 107231 | None | code264 | Modular Switches, Sockets, Fan Regulators, TV/Telephone sockets with Networking&Telecommunications Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator | Each | 357.0 | 357.0 | 60.0 | False | None | None | False | None | False | 21420.0 | 0 |
3122169 | 107231 | None | code265 | Modular Switches, Sockets, Fan Regulators, TV/Telephone sockets with Networking&Telecommunications Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16 Amps One Way switch | Each | 180.0 | 180.0 | 22.0 | False | None | None | False | None | False | 3960.0 | 0 |
3122170 | 107231 | None | code266 | Modular Switches, Sockets, Fan Regulators, TV/Telephone sockets with Networking&Telecommunications Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16 Amps universel socket | Each | 236.0 | 236.0 | 18.0 | False | None | None | False | None | False | 4248.0 | 0 |
3122171 | 107231 | None | code267 | Modular Switches, Sockets, Fan Regulators, TV/Telephone sockets with Networking&Telecommunications Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Telephone Socket - RJ 11/TV Socket | Each | 156.0 | 156.0 | 6.0 | False | None | None | False | None | False | 936.0 | 0 |
3122172 | 107231 | None | code268 | Supplying and Fixing regular MCB distribution board on wall / wood board / flush mounting using required clamps, bolts, nuts, etc., with provision for fixing suitable type capacity MCB's single phase / Three phase double door with powder coated painting, made out of 14 SWG MS enclosure, complete. 4 Way TPN Distribution Board | Each | 4038.0 | 4038.0 | 1.0 | False | None | None | False | None | False | 4038.0 | 0 |
3122173 | 107231 | None | code269 | Supplying and Fixing regular MCB distribution board on wall / wood board / flush mounting using required clamps, bolts, nuts, etc., with provision for fixing suitable type capacity MCB's single phase / Three phase double door with powder coated painting, made out of 14 SWG MS enclosure, complete. 6 Way TPN Distribution Board | Each | 4940.0 | 4940.0 | 1.0 | False | None | None | False | None | False | 4940.0 | 0 |
3122174 | 107231 | None | code270 | Supplying and Fixing regular MCB distribution board on wall / wood board / flush mounting using required clamps, bolts, nuts, etc., with provision for fixing suitable type capacity MCB's single phase / Three phase double door with powder coated painting, made out of 14 SWG MS enclosure, complete. 8 Way TPN Distribution Board | Each | 6091.0 | 6091.0 | 3.0 | False | None | None | False | None | False | 18273.0 | 0 |
3122175 | 107231 | None | code271 | Supplying and Fixing regular MCB distribution board on wall / wood board / flush mounting using required clamps, bolts, nuts, etc., with provision for fixing suitable type capacity MCB's single phase / Three phase double door with powder coated painting, made out of 14 SWG MS enclosure, complete. 12Way SP & N | Each | 2329.0 | 2329.0 | 2.0 | False | None | None | False | None | False | 4658.0 | 0 |
3122176 | 107231 | None | code272 | Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10 kA and wiring complete as required confirming to IEC 60898. 6-32Amps SP | Each | 415.0 | 415.0 | 60.0 | False | None | None | False | None | False | 24900.0 | 0 |
3122177 | 107231 | None | code273 | Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10 kA and wiring complete as required confirming to IEC 60898. 40 Amps TPN | Each | 3044.0 | 3044.0 | 4.0 | False | None | None | False | None | False | 12176.0 | 0 |
3122178 | 107231 | None | code274 | Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10 kA and wiring complete as required confirming to IEC 60898. 50-63AmpsTPN | Each | 3088.0 | 3088.0 | 5.0 | False | None | None | False | None | False | 15440.0 | 0 |
3122179 | 107231 | None | code275 | Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10 kA and wiring complete as required confirming to IEC 60898. 40 Amps DP | Each | 1060.0 | 1060.0 | 3.0 | False | None | None | False | None | False | 3180.0 | 0 |
3122180 | 107231 | None | code276 | Supplying , fixing and wiring Residual Current Circuit Breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood / panel board. 63 Amps 4 Pole, 300mA | Each | 5545.0 | 5545.0 | 3.0 | False | None | None | False | None | False | 16635.0 | 0 |
3122181 | 107231 | None | code277 | TELEPHONE WORKS & DATA WORKS Supplying and drawing PVC flexible one pair telephone unarmoured tinned Copper cable of approved make. 2 Pair | Mtr | 21.0 | 21.0 | 120.0 | False | None | None | False | None | False | 2520.0 | 0 |
3122182 | 107231 | None | code278 | TELEPHONE WORKS & DATA WORKS Supplying and drawing PVC flexible one pair telephone unarmoured tinned Copper cable of approved make. 5 Pair | Mtr | 46.0 | 46.0 | 60.0 | False | None | None | False | None | False | 2760.0 | 0 |
3122183 | 107231 | None | code279 | Supplying and Drawing UTP-CAT - 6E LAN Cable | Mtr | 38.0 | 38.0 | 50.0 | False | None | None | False | None | False | 1900.0 | 0 |
3122184 | 107231 | None | code280 | Telephone Junction Box (Main Distribution Frame) - 20 Pair -2 Nos Supplying and fixing angle iron frame work fabricated out of M.S angle iron .. and M.S.flat .. with bolts , washers etc., and painted with 2 coats of red oxide and then two coats of approved paint . a) 40 x 40 x 6 mm . | Mtr | 305.0 | 305.0 | 1.0 | False | None | None | False | None | False | 305.0 | 0 |
3122185 | 107231 | None | code281 | Telephone Junction Box (Main Distribution Frame) - 20 Pair -2 Nos Supplying and fixing angle iron frame work fabricated out of M.S angle iron .. and M.S.flat .. with bolts , washers etc., and painted with 2 coats of red oxide and then two coats of approved paint . b) 50 x 50 x6 mm . | Mtr | 395.0 | 395.0 | 1.0 | False | None | None | False | None | False | 395.0 | 0 |
3122186 | 107231 | None | code282 | Fabricating supplying and mounting MS box made out …. SWG suitable for floor / wall mounting , fully weather poof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper poof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7 tank treatment with powder coated paint and finally finished with approved colour etc., complete . b) 14 SWG | Sq CM | 0.5 | 0.5 | 3000.0 | False | None | None | False | None | False | 1500.0 | 0 |
3122187 | 107231 | None | code283 | Supplying, fixing and wiring of earth electrode for grounding of lifts, Transformers DG Sets etc, using 40mm dia 2.9 mm thick 2.5 meter long GI pipe with GI nnel with mesh & suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400 X 400 X 400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrode should be covered 150 mm alround with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using bolts and nuts.(KPWD SR 2019-2020 /I.No.6.2/Pg.No.40). | No | 4150.0 | 4150.0 | 4.0 | False | None | None | False | None | False | 16600.0 | 0 |
3122188 | 107231 | None | code284 | Supply and Installation of Conventional type, 5 segment 50mm dia hollow copper spike (air termination rod) for lightning protection with copper down rod and necessary fixing hardware as per IS 2309, 1969 ( MR) | No | 5200.0 | 5200.0 | 2.0 | False | None | None | False | None | False | 10400.0 | 0 |
3122189 | 107231 | None | code285 | Supplying and running of GI/Copper stripes for grounding connections, using necessary fixing materials as required.(KPWD SR 2019-2020 /I.No.6.3.1, 6.3.2 /Pg.No.40). a) 25 X 3 mm GI strip | Mtr | 75.0 | 75.0 | 200.0 | False | None | None | False | None | False | 15000.0 | 0 |
3122190 | 107231 | None | code286 | Supplying and running of GI/Copper stripes for grounding connections, using necessary fixing materials as required.(KPWD SR 2019-2020 /I.No.6.3.1, 6.3.2 /Pg.No.40). a) 25 X 6 mm GI Strip | Mtr | 115.0 | 115.0 | 50.0 | False | None | None | False | None | False | 5750.0 | 0 |
3122191 | 107231 | None | code287 | Supplying and running GI/Copper conductor for grounding and ( along with other wires in conduit system of wiring ) using necessary suitable size clamps, Nails, gattas/Spacers etc,.(KPWD SR 2019-2020 /I.No.6.18.6, 6.18.5, 6.18.3, 6.18.2 /Pg.No.43-44). a) 8 SWG Copper wire | Mtr | 105.0 | 105.0 | 100.0 | False | None | None | False | None | False | 10500.0 | 0 |
3122192 | 107231 | None | code288 | Supplying and running GI/Copper conductor for grounding and ( along with other wires in conduit system of wiring ) using necessary suitable size clamps, Nails, gattas/Spacers etc,.(KPWD SR 2019-2020 /I.No.6.18.6, 6.18.5, 6.18.3, 6.18.2 /Pg.No.43-44). b) 10 SWG Copper wire | Mtr | 68.0 | 68.0 | 100.0 | False | None | None | False | None | False | 6800.0 | 0 |
3122193 | 107231 | None | code289 | Supplying and running GI/Copper conductor for grounding and ( along with other wires in conduit system of wiring ) using necessary suitable size clamps, Nails, gattas/Spacers etc,.(KPWD SR 2019-2020 /I.No.6.18.6, 6.18.5, 6.18.3, 6.18.2 /Pg.No.43-44). c) 8 SWG GI wire | Mtr | 19.0 | 19.0 | 20.0 | False | None | None | False | None | False | 380.0 | 0 |
3122194 | 107231 | None | code290 | Supplying and running GI/Copper conductor for grounding and ( along with other wires in conduit system of wiring ) using necessary suitable size clamps, Nails, gattas/Spacers etc,.(KPWD SR 2019-2020 /I.No.6.18.6, 6.18.5, 6.18.3, 6.18.2 /Pg.No.43-44). d) 10 SWG GI wire | Mtr | 15.0 | 15.0 | 20.0 | False | None | None | False | None | False | 300.0 | 0 |
3122195 | 107231 | None | code291 | Supplying and fixing 2mm thick perforated cable GI tray with on existing MS angle support using necessary GI bolts/nuts and washer or welding as required. a. 450 X 50 mm | Mtr | 818.0 | 818.0 | 30.0 | False | None | None | False | None | False | 24540.0 | 0 |
3122196 | 107231 | None | code292 | ELECTRICAL FIXTURES Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting. 1x2 ' - 9/10w | Each | 551.0 | 551.0 | 80.0 | False | None | None | False | None | False | 44080.0 | 0 |
3122197 | 107231 | None | code293 | ELECTRICAL FIXTURES Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting. 1x4' - 20/22 w | Each | 690.0 | 690.0 | 40.0 | False | None | None | False | None | False | 27600.0 | 0 |
3122198 | 107231 | None | code294 | ELECTRICAL FIXTURES Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting. 2x4' - 20/22 w | Each | 1269.0 | 1269.0 | 4.0 | False | None | None | False | None | False | 5076.0 | 0 |
3122199 | 107231 | None | code295 | LED Type Tube Light Fitting - Fixing Fixing all types and capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafter / griders using 23/0.0076" twin twisted PVC insulated wires, required no.s of round blocks and clamps. a) On Wall / Ceiling / Rafter / Griders | Each | 122.0 | 122.0 | 180.0 | False | None | None | False | None | False | 21960.0 | 0 |
3122200 | 107231 | None | code296 | LED Type Tube Light Fitting - Fixing Fixing all types and capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafter / griders using 23/0.0076" twin twisted PVC insulated wires, required no.s of round blocks and clamps. b) Using necessary length of G.I. Chain | Each | 263.0 | 263.0 | 60.0 | False | None | None | False | None | False | 15780.0 | 0 |
3122201 | 107231 | None | code297 | Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder
coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED Square or round down light 10-12 W | Each | 885.0 | 885.0 | 6.0 | False | None | None | False | None | False | 5310.0 | 0 |
3122202 | 107231 | None | code298 | Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder
coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED Square or round down light 15-18 W | Each | 1324.0 | 1324.0 | 25.0 | False | None | None | False | None | False | 33100.0 | 0 |
3122203 | 107231 | None | code299 | Fixing all types and capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafter / griders using 23/0.0076" twin twisted PVC insulated wires, required no.s of round blocks and clamps. a) On Wall / Ceiling / Rafter / Griders | Each | 122.0 | 122.0 | 25.0 | False | None | None | False | None | False | 3050.0 | 0 |
3122204 | 107231 | None | code300 | Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder
coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED Square or round down light 5-6 W (Mirror Light) | Each | 574.0 | 574.0 | 20.0 | False | None | None | False | None | False | 11480.0 | 0 |
3122205 | 107231 | None | code301 | Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder
coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED Square or round down light 10-12 W (Bulk head Light) | Each | 885.0 | 885.0 | 10.0 | False | None | None | False | None | False | 8850.0 | 0 |
3122206 | 107231 | None | code302 | Fixing all types and capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafter / griders using 23/0.0076" twin twisted PVC insulated wires, required no.s of round blocks and clamps. a) On Wall / Ceiling / Rafter / Griders | Each | 122.0 | 122.0 | 15.0 | False | None | None | False | None | False | 1830.0 | 0 |
3122207 | 107231 | None | code303 | a)Capacitor Type Ceiling Fan - Supply Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system 48" Sweep (1200mm) Regular model | Each | 2984.0 | 2984.0 | 40.0 | False | None | None | False | None | False | 119360.0 | 0 |
3122208 | 107231 | None | code304 | Supplying wall mounting Fan suitable to operate at single-phase 230V AC supply . 400 mm Sweep | Each | 3212.0 | 3212.0 | 40.0 | False | None | None | False | None | False | 128480.0 | 0 |
3122209 | 107231 | None | code305 | Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin
twisted wire of approved quality, mounted on a suitable size wooden board and wired. | Each | 315.0 | 315.0 | 100.0 | False | None | None | False | None | False | 31500.0 | 0 |
3122210 | 107231 | None | code306 | a)Supplying exhaust fan of 1440 RPM of 300mm (12" ) size with bracket blades complete for light duty suitable to operate on 230v 50Hz , AC Supply… | Each | 2969.0 | 2969.0 | 25.0 | False | None | None | False | None | False | 74225.0 | 0 |
3122211 | 107231 | None | code307 | Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. | Each | 707.0 | 707.0 | 25.0 | False | None | None | False | None | False | 17675.0 | 0 |
3122212 | 107231 | None | code308 | Supplying , fixing & wiring earth leakage relay with core balanced current transformer suitable for single phase 50 HZ AC with latest microcontroller based, digital readout of pecentage leakage current, programable delay / auto / maunal reset facility suitable to mount on DIN rail / flush mounting on panel board . | Each | 9255.0 | 9255.0 | 1.0 | False | None | None | False | None | False | 9255.0 | 0 |
3122213 | 107231 | None | code309 | Supplying & fixing of shunt trip suitable for MCCB.CBCT . | Each | 1703.0 | 1703.0 | 1.0 | False | None | None | False | None | False | 1703.0 | 0 |
3122214 | 107231 | None | code310 | Supplying , fixing of LED type panel board indicating lamp with required colour suitable for 230/440v AC 50Hz 12/24v DC. | Each | 515.0 | 515.0 | 6.0 | False | None | None | False | None | False | 3090.0 | 0 |
3122215 | 107231 | None | code311 | Supplying , fixing and wiring 0 to 600 Volts 96x96 mm AC Voltmeter on exising panel / woodboard . | Each | 452.0 | 452.0 | 1.0 | False | None | None | False | None | False | 452.0 | 0 |
3122216 | 107231 | None | code312 | Supplying , fixing and wiring rotary selector switch suitable for Voltmeter . | Each | 160.0 | 160.0 | 1.0 | False | None | None | False | None | False | 160.0 | 0 |
3122217 | 107231 | None | code313 | Supplying , fixing and wiring 3 Phase Digital Ammeter | Each | 1425.0 | 1425.0 | 1.0 | False | None | None | False | None | False | 1425.0 | 0 |
3122218 | 107231 | None | code314 | Supplying , fixing and wiring rotary selector switch suitable for Ammeter | Each | 200.0 | 200.0 | 1.0 | False | None | None | False | None | False | 200.0 | 0 |
3122219 | 107231 | None | code315 | Supplying , fixing and wiring 50/5 to 400/5 Amps 5 VA burden current Transformer .class 0.5 accuracy tape wound | Each | 562.0 | 562.0 | 6.0 | False | None | None | False | None | False | 3372.0 | 0 |
3122220 | 107231 | None | code316 | Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 Amps three phase 4 wire whole current class-1 Accuracy Energy Meter. | Each | 5705.0 | 5705.0 | 1.0 | False | None | None | False | None | False | 5705.0 | 0 |
3122221 | 107231 | None | code317 | Supplying & fixing Moulded Case Circuit Breaker(MCCB) over the existing wood/panel board using necessary screws, bolts, nuts and wring complete . Protection of Overload and Shortcircuit with thermal Magnetic / Microprocessed release and Earth Fault as per IS-13947 ( Icu=Ics ) a. Four POLE,160 Amps 25KA | Each | 8487.0 | 8487.0 | 1.0 | False | None | None | False | None | False | 8487.0 | 0 |
3122222 | 107231 | None | code318 | Supplying & fixing Moulded Case Circuit Breaker(MCCB) over the existing wood/panel board using necessary screws, bolts, nuts and wring complete . Protection of Overload and Shortcircuit with thermal Magnetic / Microprocessed release and Earth Fault as per IS-13947 ( Icu=Ics ) b. Three POLE,63 Amps 25KA | Each | 3088.0 | 3088.0 | 2.0 | False | None | None | False | None | False | 6176.0 | 0 |
3122223 | 107231 | None | code319 | Supplying & fixing miniature Circuit breakers on existing MCB distribution boards using necessary fixing materials and C-type curve,indicator ON/OFF energy cross-3 with short circuit brreaking capacity of 10K and complete wiring as required to IEC 60898. A) 6-32 Amps SP | Each | 415.0 | 415.0 | 3.0 | False | None | None | False | None | False | 1245.0 | 0 |
3122224 | 107231 | None | code320 | Supplying & fixing miniature Circuit breakers on existing MCB distribution boards using necessary fixing materials and C-type curve,indicator ON/OFF energy cross-3 with short circuit brreaking capacity of 10K and complete wiring as required to IEC 60898. B) 40 Amps DP | Each | 1060.0 | 1060.0 | 6.0 | False | None | None | False | None | False | 6360.0 | 0 |
3122225 | 107231 | None | code321 | Supplying & fixing miniature Circuit breakers on existing MCB distribution boards using necessary fixing materials and C-type curve,indicator ON/OFF energy cross-3 with short circuit brreaking capacity of 10K and complete wiring as required to IEC 60898. C) 50-63A,TPN,MCB | Each | 3088.0 | 3088.0 | 12.0 | False | None | None | False | None | False | 37056.0 | 0 |
3122226 | 107231 | None | code322 | Supplying PVC/GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely. 20mm | Mtr | 19.0 | 19.0 | 5.0 | False | None | None | False | None | False | 95.0 | 0 |
3122227 | 107231 | None | code323 | Supplying PVC/GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely. 25mm | Mtr | 22.0 | 22.0 | 5.0 | False | None | None | False | None | False | 110.0 | 0 |
3122228 | 107231 | None | code324 | Supplying PVC/GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely. 32mm | Mtr | 29.0 | 29.0 | 5.0 | False | None | None | False | None | False | 145.0 | 0 |
3122229 | 107231 | None | code325 | Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. a) 250 Amps 4 x 30 x 10 mm Aluminum strips . | Mtr | 3435.0 | 3435.0 | 1.6 | False | None | None | False | None | False | 5496.0 | 0 |
3122230 | 107231 | None | code326 | Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. a) 100 Amps 4 x 30 x 6 mm Aluminum strips . | Mtr | 2465.0 | 2465.0 | 0.6 | False | None | None | False | None | False | 1479.0 | 0 |
3122231 | 107231 | None | code327 | Supplying and fixing angle iron frame work fabricated out of M.S angle iron .. And M.S.flat .. With bolts , washers etc., and painted with 2 coats of red oxide and then two coats of approved paint . a) 40 x 40 x 6 mm . | Mtr | 305.0 | 305.0 | 8.0 | False | None | None | False | None | False | 2440.0 | 0 |
3122232 | 107231 | None | code328 | Supplying and fixing angle iron frame work fabricated out of M.S angle iron .. And M.S.flat .. With bolts , washers etc., and painted with 2 coats of red oxide and then two coats of approved paint . b) 50 x 50 x6 mm . | Mtr | 395.0 | 395.0 | 5.0 | False | None | None | False | None | False | 1975.0 | 0 |
3122233 | 107231 | None | code329 | Supplying and fixing angle iron frame work fabricated out of M.S angle iron .. And M.S.flat .. With bolts , washers etc., and painted with 2 coats of red oxide and then two coats of approved paint . c) 75 x75 x 6 mm . | Mtr | 555.0 | 555.0 | 5.0 | False | None | None | False | None | False | 2775.0 | 0 |
3122234 | 107231 | None | code330 | Supplying and fixing angle iron frame work fabricated out of M.S angle iron .. And M.S.flat .. With bolts , washers etc., and painted with 2 coats of red oxide and then two coats of approved paint . d ) 50 x 100 x 50 x 6 mm C channel . | Mtr | 756.0 | 756.0 | 5.0 | False | None | None | False | None | False | 3780.0 | 0 |
3122235 | 107231 | None | code331 | Fabricating supplying and mounting MS box made out …SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with
hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. a) 14 SWG | Sq CM | 0.5 | 0.5 | 39600.0 | False | None | None | False | None | False | 19800.0 | 0 |
3122236 | 107231 | None | code332 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required . 25 x 6 mm | Mtr | 160.0 | 160.0 | 3.0 | False | None | None | False | None | False | 480.0 | 0 |
3122237 | 107231 | None | code333 | Main LT Panel UG Cables, Ext. Lighting Supplying , fixing & wiring earth leakage relay with core balanced current transformer suitable for single phase 50 HZ AC with latest microcontroller based, digital readout of pecentage leakage current, programable delay / auto / maunal reset facility suitable to mount on DIN rail / flush mounting on panel board . | Each | 9255.0 | 9255.0 | 1.0 | False | None | None | False | None | False | 9255.0 | 0 |
3122238 | 107231 | None | code334 | Supplying & fixing of shunt trip suitable for MCCB.CBCT . | Each | 1703.0 | 1703.0 | 1.0 | False | None | None | False | None | False | 1703.0 | 0 |
3122239 | 107231 | None | code335 | Supplying , fixing of LED type panel board indicating lamp with required colour suitable for 230/440v AC 50Hz 12/24v DC. | Each | 515.0 | 515.0 | 4.0 | False | None | None | False | None | False | 2060.0 | 0 |
3122240 | 107231 | None | code336 | Supplying of multi function Digital meter with three line back light LCD type display for V, C, F, KW, PF, KVA , KWH, KVAR suitable for 3 phase 4 wire LT network with IP 54 degree of protection and completely wired as required with Communication port and class0.5 accuracy. | Each | 9315.0 | 9315.0 | 1.0 | False | None | None | False | None | False | 9315.0 | 0 |
3122241 | 107231 | None | code337 | Supplying , fixing and wiring 50/5 to 400/5 Amps 5 VA burden current Transformer .class 0.5 accuracy tape wound | Each | 562.0 | 562.0 | 4.0 | False | None | None | False | None | False | 2248.0 | 0 |
3122242 | 107231 | None | code338 | Supplying & fixing Moulded Case Circuit Breaker(MCCB) over the existing wood/panel board using necessary screws, bolts, nuts and wring complete . Protection of Overload and Shortcircuit with thermal Magnetic / Microprocessed release and Earth Fault as per IS-13947 ( Icu=Ics ) b. 250 Amps 35KA | Each | 23545.0 | 23545.0 | 1.0 | False | None | None | False | None | False | 23545.0 | 0 |
3122243 | 107231 | None | code339 | Supplying & fixing Moulded Case Circuit Breaker(MCCB) over the existing wood/panel board using necessary screws, bolts, nuts and wring complete . Protection of Overload and Shortcircuit with thermal Magnetic / Microprocessed release and Earth Fault as per IS-13947 ( Icu=Ics ) 160Amps 25 KA | Each | 11050.0 | 11050.0 | 1.0 | False | None | None | False | None | False | 11050.0 | 0 |
3122244 | 107231 | None | code340 | Supplying & fixing Moulded Case Circuit Breaker(MCCB) over the existing wood/panel board using necessary screws, bolts, nuts and wring complete . Protection of Overload and Shortcircuit with thermal Magnetic / Microprocessed release and Earth Fault as per IS-13947 ( Icu=Ics ) 100Amps 25 KA | Each | 6086.0 | 6086.0 | 1.0 | False | None | None | False | None | False | 6086.0 | 0 |
3122245 | 107231 | None | code341 | Supplying & fixing miniature Circuit breakers on existing MCB distribution boards using necessary fixing materials and C-type curve,indicator ON/OFF energy cross-3 with short circuit brreaking capacity of 10K and complete wiring as required to IEC 60898. A) 6-32 Amps SP | Each | 415.0 | 415.0 | 4.0 | False | None | None | False | None | False | 1660.0 | 0 |
3122246 | 107231 | None | code342 | Supplying & fixing miniature Circuit breakers on existing MCB distribution boards using necessary fixing materials and C-type curve,indicator ON/OFF energy cross-3 with short circuit brreaking capacity of 10K and complete wiring as required to IEC 60898. B) 50-63A,TPN,MCB | Each | 3088.0 | 3088.0 | 1.0 | False | None | None | False | None | False | 3088.0 | 0 |
3122247 | 107231 | None | code343 | Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 Amps three phase 4 wire whole current class-1 Accuracy Energy Meter. | Each | 5075.0 | 5075.0 | 2.0 | False | None | None | False | None | False | 10150.0 | 0 |
3122248 | 107231 | None | code344 | Supplying PVC/GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely. 20mm | Mtr | 19.0 | 19.0 | 7.0 | False | None | None | False | None | False | 133.0 | 0 |
3122249 | 107231 | None | code345 | Supplying PVC/GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely. 25mm | Mtr | 22.0 | 22.0 | 12.0 | False | None | None | False | None | False | 264.0 | 0 |
3122250 | 107231 | None | code346 | Supplying PVC/GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely. 32mm | Mtr | 29.0 | 29.0 | 7.0 | False | None | None | False | None | False | 203.0 | 0 |
3122251 | 107231 | None | code347 | Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. a) 400 Amps 4 x 50 x10 mm Aluminum strips . | Mtr | 4445.0 | 4445.0 | 1.0 | False | None | None | False | None | False | 4445.0 | 0 |
3122252 | 107231 | None | code348 | Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. b) 250 Amps 4 x 30 x 10 mm Aluminum strips . | Mtr | 3435.0 | 3435.0 | 1.0 | False | None | None | False | None | False | 3435.0 | 0 |
3122253 | 107231 | None | code349 | Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. c) 100 Amps 4 x 30 x 6 mm Aluminum strips . | Mtr | 2465.0 | 2465.0 | 1.0 | False | None | None | False | None | False | 2465.0 | 0 |
3122254 | 107231 | None | code350 | Supplying and fixing angle iron frame work fabricated out of M.S angle iron .. And M.S.flat .. With bolts , washers etc., and painted with 2 coats of red oxide and then two coats of approved paint . a) 40 x 40 x 6 mm . | Mtr | 305.0 | 305.0 | 15.0 | False | None | None | False | None | False | 4575.0 | 0 |
3122255 | 107231 | None | code351 | Supplying and fixing angle iron frame work fabricated out of M.S angle iron .. And M.S.flat .. With bolts , washers etc., and painted with 2 coats of red oxide and then two coats of approved paint . b) 50 x 50 x6 mm . | Mtr | 395.0 | 395.0 | 12.0 | False | None | None | False | None | False | 4740.0 | 0 |
3122256 | 107231 | None | code352 | Supplying and fixing angle iron frame work fabricated out of M.S angle iron .. And M.S.flat .. With bolts , washers etc., and painted with 2 coats of red oxide and then two coats of approved paint . c) 75 x75 x 6 mm . | Mtr | 555.0 | 555.0 | 12.0 | False | None | None | False | None | False | 6660.0 | 0 |
3122257 | 107231 | None | code353 | Supplying and fixing angle iron frame work fabricated out of M.S angle iron .. And M.S.flat .. With bolts , washers etc., and painted with 2 coats of red oxide and then two coats of approved paint . d ) 50 x 100 x 50 x 6 mm C channel . | Mtr | 756.0 | 756.0 | 5.0 | False | None | None | False | None | False | 3780.0 | 0 |
3122258 | 107231 | None | code354 | Fabricating supplying and mounting MS box made out …SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with
hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. a) 14 SWG | Sq CM | 0.5 | 0.5 | 30000.0 | False | None | None | False | None | False | 15000.0 | 0 |
3122259 | 107231 | None | code355 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required . 25 x 6 mm | Mtr | 115.0 | 115.0 | 3.0 | False | None | None | False | None | False | 345.0 | 0 |
3122260 | 107231 | None | code356 | Supplying , fixing & wiring earth leakage relay with core balanced current transformer suitable for single phase 50 HZ AC with latest microcontroller based, digital readout of pecentage leakage current, programable delay / auto / maunal reset facility suitable to mount on DIN rail / flush mounting on panel board . | Each | 9255.0 | 9255.0 | 1.0 | False | None | None | False | None | False | 9255.0 | 0 |
3122261 | 107231 | None | code357 | Supplying & fixing of shunt trip suitable for MCCB.CBCT . | Each | 1703.0 | 1703.0 | 1.0 | False | None | None | False | None | False | 1703.0 | 0 |
3122262 | 107231 | None | code358 | Supplying , fixing of LED type panel board indicating lamp with required colour suitable for 230/440v AC 50Hz 12/24v DC. | Each | 515.0 | 515.0 | 6.0 | False | None | None | False | None | False | 3090.0 | 0 |
3122263 | 107231 | None | code359 | Supplying , fixing and wiring 0 to 600 Volts 96x96 mm AC Voltmeter on exising panel / woodboard . | Each | 452.0 | 452.0 | 1.0 | False | None | None | False | None | False | 452.0 | 0 |
3122264 | 107231 | None | code360 | Supplying , fixing and wiring rotary selector switch suitable for Voltmeter . | Each | 160.0 | 160.0 | 1.0 | False | None | None | False | None | False | 160.0 | 0 |
3122265 | 107231 | None | code361 | Supplying , fixing and wiring 3 Phase Digital Ammeter | Each | 1425.0 | 1425.0 | 1.0 | False | None | None | False | None | False | 1425.0 | 0 |
3122266 | 107231 | None | code362 | Supplying , fixing and wiring rotary selector switch suitable for Ammeter | Each | 200.0 | 200.0 | 1.0 | False | None | None | False | None | False | 200.0 | 0 |
3122267 | 107231 | None | code363 | Supplying , fixing and wiring 50/5 to 400/5 Amps 5 VA burden current Transformer .class 0.5 accuracy tape wound | Each | 562.0 | 562.0 | 6.0 | False | None | None | False | None | False | 3372.0 | 0 |
3122268 | 107231 | None | code364 | Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 Amps three phase 4 wire whole current class-1 Accuracy Energy Meter. | Each | 5705.0 | 5705.0 | 1.0 | False | None | None | False | None | False | 5705.0 | 0 |
3122269 | 107231 | None | code365 | Supplying & fixing Moulded Case Circuit Breaker(MCCB) over the existing wood/panel board using necessary screws, bolts, nuts and wring complete . Protection of Overload and Shortcircuit with thermal Magnetic / Microprocessed release and Earth Fault as per IS-13947 ( Icu=Ics ) A) 4 POLE 100Amps 25 KA | Each | 8487.0 | 8487.0 | 1.0 | False | None | None | False | None | False | 8487.0 | 0 |
3122270 | 107231 | None | code366 | Supplying & fixing Moulded Case Circuit Breaker(MCCB) over the existing wood/panel board using necessary screws, bolts, nuts and wring complete . Protection of Overload and Shortcircuit with thermal Magnetic / Microprocessed release and Earth Fault as per IS-13947 ( Icu=Ics ) B) 3 POLE 63 Amps 25 KA | Each | 3088.0 | 3088.0 | 1.0 | False | None | None | False | None | False | 3088.0 | 0 |
3122271 | 107231 | None | code367 | Supplying & fixing miniature Circuit breakers on existing MCB distribution boards using necessary fixing materials and C-type curve,indicator ON/OFF energy cross-3 with short circuit brreaking capacity of 10K and complete wiring as required to IEC 60898. A) 6-32 Amps SP | Each | 415.0 | 415.0 | 3.0 | False | None | None | False | None | False | 1245.0 | 0 |
3122272 | 107231 | None | code368 | Supplying & fixing miniature Circuit breakers on existing MCB distribution boards using necessary fixing materials and C-type curve,indicator ON/OFF energy cross-3 with short circuit brreaking capacity of 10K and complete wiring as required to IEC 60898. B) 50-63A,TPN,MCB | Each | 3088.0 | 3088.0 | 1.0 | False | None | None | False | None | False | 3088.0 | 0 |
3122273 | 107231 | None | code369 | Supplying PVC/GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely. 20mm | Mtr | 19.0 | 19.0 | 5.0 | False | None | None | False | None | False | 95.0 | 0 |
3122274 | 107231 | None | code370 | Supplying PVC/GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely. 25mm | Mtr | 22.0 | 22.0 | 5.0 | False | None | None | False | None | False | 110.0 | 0 |
3122275 | 107231 | None | code371 | Supplying PVC/GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely. 32mm | Mtr | 29.0 | 29.0 | 2.0 | False | None | None | False | None | False | 58.0 | 0 |
3122276 | 107231 | None | code372 | Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. a) 250 Amps 4 x 30 x 10 mm Aluminum strips . | Mtr | 3435.0 | 3435.0 | 1.8 | False | None | None | False | None | False | 6183.0 | 0 |
3122277 | 107231 | None | code373 | Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. b) 100 Amps 4 x 30 x 6 mm Aluminum strips . | Mtr | 2465.0 | 2465.0 | 0.5 | False | None | None | False | None | False | 1232.5 | 0 |
3122278 | 107231 | None | code374 | Supplying and fixing angle iron frame work fabricated out of M.S angle iron .. And M.S.flat .. With bolts , washers etc., and painted with 2 coats of red oxide and then two coats of approved paint . a) 40 x 40 x 6 mm . | Mtr | 305.0 | 305.0 | 10.0 | False | None | None | False | None | False | 3050.0 | 0 |
3122279 | 107231 | None | code375 | Supplying and fixing angle iron frame work fabricated out of M.S angle iron .. And M.S.flat .. With bolts , washers etc., and painted with 2 coats of red oxide and then two coats of approved paint . b) 50 x 50 x6 mm . | Mtr | 395.0 | 395.0 | 10.0 | False | None | None | False | None | False | 3950.0 | 0 |
3122280 | 107231 | None | code376 | Supplying and fixing angle iron frame work fabricated out of M.S angle iron .. And M.S.flat .. With bolts , washers etc., and painted with 2 coats of red oxide and then two coats of approved paint . c) 75 x75 x 6 mm . | Mtr | 555.0 | 555.0 | 5.0 | False | None | None | False | None | False | 2775.0 | 0 |
3122281 | 107231 | None | code377 | Supplying and fixing angle iron frame work fabricated out of M.S angle iron .. And M.S.flat .. With bolts , washers etc., and painted with 2 coats of red oxide and then two coats of approved paint . d ) 50 x 100 x 50 x 6 mm C channel . | Mtr | 756.0 | 756.0 | 3.0 | False | None | None | False | None | False | 2268.0 | 0 |
3122282 | 107231 | None | code378 | Fabricating supplying and mounting MS box made out …SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with
hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. a) 14 SWG | Sq CM | 0.5 | 0.5 | 22000.0 | False | None | None | False | None | False | 11000.0 | 0 |
3122283 | 107231 | None | code379 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required . 25 x 6 mm | Mtr | 116.0 | 116.0 | 2.0 | False | None | None | False | None | False | 232.0 | 0 |
3122284 | 107231 | None | code380 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring
strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 3.5 Core 240 Sq. mm (2 Runs from Transformer to Academic Block Electrical Room) | Mtr | 1130.0 | 1130.0 | 560.0 | False | None | None | False | None | False | 632800.0 | 0 |
3122285 | 107231 | None | code381 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring
strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 3.5 Core 185 Sq. mm (From 125 KVA DG set to Academic Block Electrical Room) | Mtr | 895.0 | 895.0 | 10.0 | False | None | None | False | None | False | 8950.0 | 0 |
3122286 | 107231 | None | code382 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring
strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 3.5 Core 150 Sq. mm (For ACA Sub Dist. Panel, Girl's and Boy's Hostel Panels) | Mtr | 720.0 | 720.0 | 20.0 | False | None | None | False | None | False | 14400.0 | 0 |
3122287 | 107231 | None | code383 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring
strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 3.5 Core 120 Sq. mm (for Capacitor Panel) | Mtr | 600.0 | 600.0 | 20.0 | False | None | None | False | None | False | 12000.0 | 0 |
3122288 | 107231 | None | code384 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring
strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 3.5 Core 50 Sq. mm (for Dining Hall and Common Service Panel) | Mtr | 300.0 | 300.0 | 25.0 | False | None | None | False | None | False | 7500.0 | 0 |
3122289 | 107231 | None | code385 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring
strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 3.5 Core 25 Sq. mm | Mtr | 180.0 | 180.0 | 50.0 | False | None | None | False | None | False | 9000.0 | 0 |
3122290 | 107231 | None | code386 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring
strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 4 Core 16 Sq. mm | Mtr | 150.0 | 150.0 | 50.0 | False | None | None | False | None | False | 7500.0 | 0 |
3122291 | 107231 | None | code387 | Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required.
6 sqmm to 16 sqmm | Mtr | 11.88 | 11.88 | 50.0 | False | None | None | False | None | False | 594.0 | 0 |
3122292 | 107231 | None | code388 | Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required.
25 sqmm to 75 sqmm | Mtr | 15.5 | 15.5 | 110.0 | False | None | None | False | None | False | 1705.0 | 0 |
3122293 | 107231 | None | code389 | Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required.
95 sqmm to 150 sqmm | Mtr | 21.0 | 21.0 | 120.0 | False | None | None | False | None | False | 2520.0 | 0 |
3122294 | 107231 | None | code390 | Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required.
185sqmm to 240 sqmm | Mtr | 35.0 | 35.0 | 90.0 | False | None | None | False | None | False | 3150.0 | 0 |
3122295 | 107231 | None | code391 | Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7) a. in soil - (ordinary) | Mtr | 76.0 | 76.0 | 12.0 | False | None | None | False | None | False | 912.0 | 0 |
3122296 | 107231 | None | code392 | Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7) b. in soil ( hard ) | Mtr | 102.0 | 102.0 | 20.0 | False | None | None | False | None | False | 2040.0 | 0 |
3122297 | 107231 | None | code393 | Supply and fixing of heavy duty cable glands suitable for UG cables of 1.1 KV class ( metal only ) a. 19/20mm dia | Each | 68.0 | 68.0 | 30.0 | False | None | None | False | None | False | 2040.0 | 0 |
3122298 | 107231 | None | code394 | Supply and fixing of heavy duty cable glands suitable for UG cables of 1.1 KV class ( metal only ) b. 25mm dia | Each | 84.0 | 84.0 | 40.0 | False | None | None | False | None | False | 3360.0 | 0 |
3122299 | 107231 | None | code395 | Supply and fixing of heavy duty cable glands suitable for UG cables of 1.1 KV class ( metal only ) c. 32 mm dia | Each | 117.0 | 117.0 | 10.0 | False | None | None | False | None | False | 1170.0 | 0 |
3122300 | 107231 | None | code396 | Supply and fixing of heavy duty cable glands suitable for UG cables of 1.1 KV class ( metal only ) d. 45mm dia | Each | 194.0 | 194.0 | 8.0 | False | None | None | False | None | False | 1552.0 | 0 |
3122301 | 107231 | None | code397 | Supply and fixing of heavy duty cable glands suitable for UG cables of 1.1 KV class ( metal only ) e. 50 mm dia | Each | 255.0 | 255.0 | 8.0 | False | None | None | False | None | False | 2040.0 | 0 |
3122302 | 107231 | None | code398 | Supply and fixing of heavy duty cable glands suitable for UG cables of 1.1 KV class ( metal only ) f. 63 mm dia | Each | 388.0 | 388.0 | 1.0 | False | None | None | False | None | False | 388.0 | 0 |
3122303 | 107231 | None | code399 | Supply and fixing of heavy duty cable glands suitable for UG cables of 1.1 KV class ( metal only ) g. 75 mm dia | Each | 496.0 | 496.0 | 2.0 | False | None | None | False | None | False | 992.0 | 0 |
3122304 | 107231 | None | code400 | Supply and fixing of heavy duty cable glands suitable for UG cables of 1.1 KV class ( metal only ) h. 100 mm dia | Each | 965.0 | 965.0 | 2.0 | False | None | None | False | None | False | 1930.0 | 0 |
3122305 | 107231 | None | code401 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sqmm | Each | 12.44 | 12.44 | 30.0 | False | None | None | False | None | False | 373.2 | 0 |
3122306 | 107231 | None | code402 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 25 sqmm long barrel | Each | 20.0 | 20.0 | 20.0 | False | None | None | False | None | False | 400.0 | 0 |
3122307 | 107231 | None | code403 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 50 sqmm long barrel | Each | 60.0 | 60.0 | 10.0 | False | None | None | False | None | False | 600.0 | 0 |
3122308 | 107231 | None | code404 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 70 sqmm long barrel | Each | 95.0 | 95.0 | 8.0 | False | None | None | False | None | False | 760.0 | 0 |
3122309 | 107231 | None | code405 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 120 sqmm long barrel | Each | 190.0 | 190.0 | 2.0 | False | None | None | False | None | False | 380.0 | 0 |
3122310 | 107231 | None | code406 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 185 sqmm long barrel | Each | 327.0 | 327.0 | 2.0 | False | None | None | False | None | False | 654.0 | 0 |
3122311 | 107231 | None | code407 | Supplying and fixing of class A (medium duty) GI pipe of wall thickness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV.
a. 80 mm | Mtr | 688.0 | 688.0 | 10.0 | False | None | None | False | None | False | 6880.0 | 0 |
3122312 | 107231 | None | code408 | Supplying and fixing of class A (medium duty) GI pipe of wall thickness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV.
c. 65 mm | Mtr | 566.0 | 566.0 | 10.0 | False | None | None | False | None | False | 5660.0 | 0 |
3122313 | 107231 | None | code409 | aSupplying and fixing 2mm thick perforated cable GI tray with on existing MS angle support using necessary GI bolts/nuts and washer or welding as required. . 450 X 50 mm | m | 818.0 | 818.0 | 2.0 | False | None | None | False | None | False | 1636.0 | 0 |
3122314 | 107231 | None | code410 | bSupplying and fixing 2mm thick perforated cable GI tray with on existing MS angle support using necessary GI bolts/nuts and washer or welding as required. . 600 X 50 mm | m | 865.0 | 865.0 | 5.0 | False | None | None | False | None | False | 4325.0 | 0 |
3122315 | 107231 | None | code411 | Supplying, fixing and wiring of earth electrode for grounding of lifts, Transformers DG Sets etc, using 40mm dia 2.9 mm thick 2.5 meter long GI pipe with GI nnel with mesh & suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400 X 400 X 400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrode should be covered 150 mm alround with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using bolts and nuts. | Each | 4150.0 | 4150.0 | 1.0 | False | None | None | False | None | False | 4150.0 | 0 |
3122316 | 107231 | None | code412 | Supplying and running of GI/Copper stripes for grounding connections, using necessary fixing materials as required a) 25 X 3 mm GI strip | m | 75.0 | 75.0 | 12.0 | False | None | None | False | None | False | 900.0 | 0 |
3122317 | 107231 | None | code413 | bSupplying and running of GI/Copper stripes for grounding connections, using necessary fixing materials as required ) 25 X 6 mm GI Strip | m | 115.0 | 115.0 | 12.0 | False | None | None | False | None | False | 1380.0 | 0 |
3122318 | 107231 | None | code414 | cSupplying and running of GI/Copper stripes for grounding connections, using necessary fixing materials as required . 40 X 6 mm | m | 160.0 | 160.0 | 3.0 | False | None | None | False | None | False | 480.0 | 0 |
3122319 | 107231 | None | code415 | Supplying and running of GI/Copper stripes for grounding connections, using necessary fixing materials as required d. 600 x 600 x 3 mm GI plate | Each | 760.0 | 760.0 | 15.0 | False | None | None | False | None | False | 11400.0 | 0 |
3122320 | 107231 | None | code416 | Supplying and running of Copper Strip GI/Copper stripes for grounding connections, using necessary fixing materials as required a. 25 X 3 mm | m | 505.0 | 505.0 | 6.0 | False | None | None | False | None | False | 3030.0 | 0 |
3122321 | 107231 | None | code417 | Supplying and running of Copper Strip GI/Copper stripes for grounding connections, using necessary fixing materials as required a. b. 25 X 6 mm | m | 958.0 | 958.0 | 6.0 | False | None | None | False | None | False | 5748.0 | 0 |
3122322 | 107231 | None | code418 | Supplying and running of Copper Strip GI/Copper stripes for grounding connections, using necessary fixing materials as required a. c. 600 x 600 x 3 mm copper plate | Each | 6900.0 | 6900.0 | 8.0 | False | None | None | False | None | False | 55200.0 | 0 |
3122323 | 107231 | None | code419 | Design,supplying,erecting testing and commissioning of passenger / hospital lift with speed of 1.0 mtr per second,variable voltage,variable frequency drive,with or without machine room for the available well size,operating at 415v 3 phase 50 cycles AC supply,powdercoated or stainless steel car entrance door enclosures with flooring,car ilumination,emergency light,intercom and fan as desired bybthe user,central opening /side opening door or without attendeant operation,7 segment display,kids buttons,call register indicator,firmen drive,ss handrails inside car,full length infra red curain in car door,automtically rescue device,voice annouciation in regional languages,Braile buttons with one year warranty and mainatance.The worksincludes providing shaft scafolding,attending minor buiders workssuch as making nitches for fixing of brackets,guide rails,counter weights lift ruuning liecence from the competent authority. With machine room-SS finsih (8 passenger lift-4 stops) | No | 1520607.0 | 1520607.0 | 1.0 | False | None | None | False | None | False | 1520607.0 | 0 |
3122324 | 107231 | None | code420 | Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and
Excluding batteries and wiring complete.(9/9.3) 10 kVA ON LINE UPS(9/9.3.5) | No | 119023.0 | 119023.0 | 5.0 | False | None | None | False | None | False | 595115.0 | 0 |
3122325 | 107231 | None | code421 | Supplying, installation, testing & commissioning of 12V ..AH
batteries in poly propylene container for D.G. sets. Low maintenance batteries, plate type..(9/9.4) | No | 22135.0 | 22135.0 | 10.0 | False | None | None | False | None | False | 221350.0 | 0 |
3122326 | 107231 | None | code422 | Supplying,erecting,testing & commissioning of 200.kVA Diesel Generator set on existing CC platform comprising of Diesel Engine developing …BHP @ 1500RPM confirming to BS 5514.The engine should be turbocharged, Air/water cooled with 10% over load for 1hour in every 12 hours of operation coupled to suitable capacity alternator rated at 415V , 0.8PF Lag 50Hz, 3Phase , 4wire system,confirming to BS 5000/IS 4722. The alternator shall be of brushlesstype, screen protected,revolving field,mounted on suitable channel iron base frame, complete with suitable capacity fuel tank,required nos. of batteries of 12/24V as per requirement , Acoustic enclosure as per CPCB approved norms. (10/10.1) 100KVA/80KW (10/10.1.9) | Set | 900956.0 | 900956.0 | 1.0 | False | None | None | False | None | False | 900956.0 | 0 |
3122327 | 107231 | None | code423 | Supply, Erection, testing and commissioning of AMF panel suitable for .....kVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .....A 4 pole contactor for alternator with thermal O/L relay,..... A 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage,
....capacity bypass switch and frequency sensing, PCC 1301controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ kVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMF module by pass Mode, Battery charger unit with inbuilt Auto/Manual and Flat/Boost facility. The complete set shall have sufficient safety and adhere to NEC, NBC 2016, IEC, CPWD specifications, PCB norms and KSGEI Acts and Rules. 62.5KVA to 125 KVA (10.2.2) | Set | 109531.0 | 109531.0 | 1.0 | False | None | None | False | None | False | 109531.0 | 0 |