3119325 | 107176 | None | code01 | Providing fixing factory made PVC Door frame of size 50x47mm with wall thickness of 5mm made out of extruded 5mm rigid PVCfoam sheet metered cut at corners jointed 2 Nos of 150mm long brackets of 15x15mm M S Square tube the entire door frame to be reinforced with 19x19mm M S Square tube of 19 gauge The door frame to be fixed to the wall using M S Screws of 65 80mm size complete as per manufacturers specification direction of Engineer in charge SR 2023 24 Vol 02 P No 105 I No 12 54 with all lead lifts loading unloading charges including cost and conveyance of all materials labour equipments and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work | Rmtr | 333.9 | 333.9 | 25.0 | False | None | None | False | None | False | 8347.5 | 0 |
3119326 | 107176 | None | code02 | Providing and fixing in position fully panelled Teak wood shutters for doors with stiles and rails of 40mm thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials labour usage charges complete as per specifications excluding cost of fixtures Vol 02 P No 100 I No 12 14 with all lead lifts loading unloading charges including cost and conveyance of all materials labour equipments and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work | Sqm | 9800.7 | 9800.7 | 13.23 | False | None | None | False | None | False | 129663.261 | 0 |
3119327 | 107176 | None | code03 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade New work two coats over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt dust mortar drops and foreign matter including preparing the surface even and sand paper smooth cost of materials labour complete as per specifications and as per directions of Engineer in charge PWD SR 2023 24 P No 45 I No 8 25 with all lead lifts loading unloading charges including cost and conveyance of all materials labour equipments and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work | Sqm | 143.85 | 143.85 | 744.75 | False | None | None | False | None | False | 107132.2875 | 0 |
3119328 | 107176 | None | code04 | Providing & fixing White vitreous china water closet squatting pan Indian type along with S or P trap including dismantling of old WC seat and S or P trap at site complete with all operations including all necessary materials labour and disposal of dismantled material i c malba, all complete as per the direction of Engineer in charge Orissa pattern W.C Pan of size 580x440 mm Orissa pattern WC Pan of size 580x440mm SR 2023 24 Vol 02 P No 178 I with all lead lifts loading unloading charges including cost and conveyance of all materials labour equipments and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work | Pan | 3724.35 | 3724.35 | 4.0 | False | None | None | False | None | False | 14897.4 | 0 |
3119329 | 107176 | None | code05 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications Two coats applied on walls 1 25 ltr 10 m² over and including one coat of Special primer applied 0 75 ltr 10 m² with paint of approved quality to give an even shade after thoroughly brooming the surface to remove all dirt dust mortar drops and foreign matter including preparing the surface even and sand paper smooth cost of materials labour complete as per specifications and as per directions of Engineer in charge SR 2023 24 Vol 02 P No 46 I No 8 33 1 with all lead lifts loading unloading charges including cost and conveyance of all materials labour equipments and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work | Sqm | 165.9 | 165.9 | 35.28 | False | None | None | False | None | False | 5852.952 | 0 |
3119330 | 107176 | None | code06 | Varnishing with varnish of approved brand and manufacture Two coats of glue sizing with copal varnish over an under coat of flatting varnish to give an even shade and produce a smooth dry and mat surface including preparing the surface after thorougly cleaning oil grease dirt and foreign mattersand papering and knotting cost of materials labour complete as per specifications and as per directions of Engineer in charge SR 2023 24 Vol 02 P No 49 I No 8 45 1 with all lead lifts loading unloading charges including cost and conveyance of all materials labour equipments and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work | Sqm | 180.6 | 180.6 | 100.78 | False | None | None | False | None | False | 18200.868 | 0 |
3119331 | 107176 | None | code07 | Providing and fixing water closet squatting pan Indian type W C pan with 100 mm sand cast Iron P or S trap 10 litre low level white P V C flushing cistern including flush pipe with manually controlled device handle lever conforming to IS 7231 with all fittings and fixtures complete including cutting and making good the walls and floors wherever required White Vitreous china Orissa pattern W C pan of size 580x440 mm with integral type foot rests SR 2023 24 Vol 02 P No 123 I No 14 1 with all lead lifts loading unloading charges including cost and conveyance of all materials labour equipments and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work | Each | 5128.2 | 5128.2 | 1.0 | False | None | None | False | None | False | 5128.2 | 0 |
3119332 | 107176 | None | code08 | Providing and fixing white vitreous china pedestal type water closet European type W C pan with seat and lid 10 litre low level white P V C flushing cistern including flush pipe with manually controlled device handle lever conforming to IS 7231 with all fittings and fixtures complete including cutting and making good the walls and floors wherever required SR 2023 24 Vol 02 P No 129 I No 14 2 1 W C pan with ISI marked white solid plastic seat and lid with all lead lifts loading unloading charges including cost and conveyance of all materials labour equipments and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work | Pan | 5079.9 | 5079.9 | 1.0 | False | None | None | False | None | False | 5079.9 | 0 |
3119333 | 107176 | None | code09 | Providing and fixing wash basin with C I brackets 15 mm C P brass pillar taps 32mm C P brass waste of standard pattern including painting of fittings and brackets cutting and making good the walls wherever require White Vitreous China Wash basin size 630x450mm with a single 15mm C P brass pillar tap SR 2023 24 Vol 02 P No 124 I No 14 7 1 White Vitreous China Wash basin size 630x450mm with a pair of 15mm C P brass pillar taps with all lead lifts loading unloading charges including cost and conveyance of all materials labour equipments and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work | Each | 3236.1 | 3236.1 | 2.0 | False | None | None | False | None | False | 6472.2 | 0 |
3119334 | 107176 | None | code10 | Constructing brick masonry chamber for underground C I inspection chamber and bends with bricks in cement mortar 1 4 1 cement : 4 coarse sand C I cover with frame light duty 500X700 mm internal dimensions, total weight of cover with frame to be not less than 38 kg weight of cover 23 kg and weight of frame 15 kg R C C top slab with 1 1 5 3 mix 1 cement 1 5 fine sand 3 graded stone aggregate 20 mm nominal size foundation concrete 1 5 10 1 cement 5 fine sand 10 graded stone aggregate 40 mm nominal size inside plastering 12 mm thick with cement mortar 1 3 1 cement 3 coarse sand finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets :With common burnt clay non modular bricks of class designation 3.5 No KBS PWD SR 2023 24 P No 126 I No 13 54 with all lead lifts loading unloading charges including cost and conveyance of all materials labour equipments and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work | Each | 6591.9 | 6591.9 | 4.0 | False | None | None | False | None | False | 26367.6 | 0 |
3119335 | 107176 | None | code11 | Bottle trap 31mm single piece moulded with height of 270mm effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal weighing not less than 260 gms SR 2023 24 Vol 02 P No 129 I No 14 37 1 with all lead lifts loading unloading charges including cost and conveyance of all materials labour equipments and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work | Each | 321.3 | 321.3 | 4.0 | False | None | None | False | None | False | 1285.2 | 0 |
3119336 | 107176 | None | code12 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm sizes respectively with automatic flushing cistern with standard flush pipe and C P brass spreaders with brass unions and G I clamps complete including painting of fittings and brackets cutting and making good the walls and floors wherever required Vol 02 P No 123 I No 14 4 with all lead lifts loading unloading charges including cost and conveyance of all materials labour equipments and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work | Each | 4676.7 | 4676.7 | 6.0 | False | None | None | False | None | False | 28060.2 | 0 |
3119337 | 107176 | None | code13 | Providing and fixing unplasticised PVC connection pipe with brass unions One urinal basin with 5 litre white P V C automatic flushing cistern SR 2023 24 Vol 02 P No 116 I No 13 8 20 mm nominal bore with all lead lifts loading unloading charges including cost and conveyance of all materials labour equipments and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work | No | 95.55 | 95.55 | 140.0 | False | None | None | False | None | False | 13377.0 | 0 |
3119338 | 107176 | None | code14 | Providing and fixing brass bib cock of approved quality 15mm nominal bore PWD SR V 2 2023-24 P No 116 I No 13 8 1 2 with all lead lifts loading unloading charges including cost and conveyance of all materials labour equipments and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work | Each | 300.3 | 300.3 | 8.0 | False | None | None | False | None | False | 2402.4 | 0 |
3119339 | 107176 | None | code15 | Supply and delivery at site GM copper alloy gate valves confirming to Class I as per IS 778 with latest amendments 1 No screwed in bonnet inside screw rising spring spindle integral seat screwed females ends confirming to IS 554 1990 body hydraulically tested 1 5HP seat standard tested 1 HP with IS mark For 25mm dia GM Copper alloy Gate valves RWS SR 2023 24 Vol 5 P No 133 I No 11.15.3 with all lead lifts loading unloading charges including cost and conveyance of all materials labour equipments and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work | Each | 1227.45 | 1227.45 | 3.0 | False | None | None | False | None | False | 3682.35 | 0 |
3119340 | 107176 | None | code16 | Providing and placing on terrace at all floor levels polyethylene water storage tank, IS 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet outlet and overflow pipes but without fittings and the base support for tank PWD SR 23-24 No 9 123 I No 13 348 with all lead lifts loading unloading charges including cost and conveyance of all materials labour equipments and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work | Ltr | 9.45 | 9.45 | 2000.0 | False | None | None | False | None | False | 18900.0 | 0 |
3119341 | 107176 | None | code17 | Supplying laying and jointing HDPE pipes of specified grade and conforming to IS 4984 2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches laying true to line and jointing of pipes and specials with electrofusion welding giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms with soft gravel or selected earth available from the excation testing and commissioning The rate is exclusive of required specials and fittings wherever necessary like saddle Tee stub ends flanged sets bedns reducers etc complete Contractor will make his own arrangements for procuring water for testing etc Note Upto 110mm dia Coil shall be used For Grade PE80 PN6 0 HDPE Grade PE80 PN8 0 110mm dia RDWS Vol 5 P No 121 I No 1 4 with all lead lifts loading unloading charges including cost and conveyance of all materials labour equipments and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work | m | 452.45 | 452.45 | 16.0 | False | None | None | False | None | False | 7239.2 | 0 |
3119342 | 107176 | None | code18 | Providing and fixing Steel work in built up tubular round square or rectangular hollow tubes etc trusses etc including cutting hoisting fixing in position and applying a priming coat of approved steel primer including welding and bolted with special shaped washers etc complete Hot finished seamless type tubes including cost of materials labour usage charges of machinery complete as per specifications and as per directions of the Engineer in Charge PWD BGM SR I No 9 2 4 P no 121 Vol 02 with all lead lifts loading unloading charges including cost and conveyance of all materials labour equipments and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work | Kg | 154.35 | 154.35 | 38.25 | False | None | None | False | None | False | 5903.8875 | 0 |
3119343 | 107176 | None | code19 | Providing and fixing precoated galvanised iron profile sheets size shape and pitch of corrugation as approved by Engineer in charge 0 50mm 0 05 total coated thickness with zinc coating 120 grams per m2 as per IS 277 in 240 mpa steel grade 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12m or as desired by Engineer in charge The sheet shall be fixed using self drilling self tapping screws of size 55x55mm with EPDM seal complete upto any pitch in horizontal vertical or curved surfaces excluding the cost of purlins rafters and trusses and including cutting to size and shape wherever required PWD BGM SR 2023 24 P No 26 I No7 38 with all lead lifts loading unloading charges including cost and conveyance of all materials labour equipments and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work | Sqm | 596.4 | 596.4 | 17.4 | False | None | None | False | None | False | 10377.36 | 0 |
3119344 | 107176 | None | code20 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1 5 1 cement 5 coarse sand finished with a top layer 6 mm thick cement plaster with cement mortar 1 6 1 cement 6 fine sand to brick masonry including rounding off corners wherever required smooth rendering providing and removing scaffolding including cost of materials labour curing complete as per specifications and as per directions of Engineer in charge Vol 02 P No 42 I No 8 8 with all lead lifts loading unloading charges including cost and conveyance of all materials labour equipments and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work | Sqm | 404.25 | 404.25 | 18.12 | False | None | None | False | None | False | 7325.01 | 0 |
3119345 | 107176 | None | code21 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends junction box elbows screws at an interval of 300 mm etc as required 3 1 7 25mm with all lead lifts loading unloading charges including cost and conveyance of all materials labour equipments and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work | m | 36.75 | 36.75 | 200.0 | False | None | None | False | None | False | 7350.0 | 0 |
3119346 | 107176 | None | code22 | Supplying PVC GI flexible conduit pipe mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely 2 1 9 with all lead lifts loading unloading charges including cost and conveyance of all materials labour equipments and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work | m | 55.65 | 55.65 | 5.0 | False | None | None | False | None | False | 278.25 | 0 |
3119347 | 107176 | None | code23 | WIRES & CABLES Point wiring using Copper wire with switch Supplying and wiring adopting loop system in existing PVC Conduit casing capping using 2x1 5mm2 Phase & Neutral & 1x1 0 mm2 Earth wire FRLS multi strand PVC insulated copper wire confirming to IS 694 and latest amendments with a 6A flush type SP control switch shall be fixed on the existing plastic sheet gang box the other end of the wires shall be terminated with sufficient loose length in a wood PVC round block complete for each outlet Short point up to 3Mtr from tapping point to out let via switch P No.2 I No 2 7 21-22 with all lead lifts loading unloading charges including cost and conveyance of all materials labour equipments and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work | Point | 299.25 | 299.25 | 6.0 | False | None | None | False | None | False | 1795.5 | 0 |
3119348 | 107176 | None | code24 | WIRES & CABLES Point wiring using Copper wire with switch Supplying and wiring adopting loop system in existing PVC Conduit casing capping using 2x1 5mm2 Phase & Neutral & 1x1 0 mm2 Earth wire FRLS multi strand PVC insulated copper wire confirming to IS 694 and latest amendments with a 6A flush type SP control switch shall be fixed on the existing plastic sheet gang box the other end of the wires shall be terminated with sufficient loose length in a wood PVC round block complete for each outlet Medium point above 3mtr up to 6Mtr from tapping point to out let via switch P No 2 I No 2 7 21-22 with all lead lifts loading unloading charges including cost and conveyance of all materials labour equipments and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work | Point | 413.7 | 413.7 | 10.0 | False | None | None | False | None | False | 4137.0 | 0 |
3119349 | 107176 | None | code25 | WIRES & CABLES Point wiring using Copper wire with switch Supplying and wiring adopting loop system in existing PVC Conduit casing capping using 2x1 5mm2 Phase & Neutral & 1x1 0 mm2 Earth wire FRLS multi strand PVC insulated copper wire confirming to IS 694 and latest amendments with a 6A flush type SP control switch shall be fixed on the existing plastic sheet gang box the other end of the wires shall be terminated with sufficient loose length in a wood PVC round block complete for each outlet Medium point above 3mtr up to 6 Mtr from tapping point to out let via switch P No 2 I No 2 7 21-22 with all lead lifts loading unloading charges including cost and conveyance of all materials labour equipments and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work | Point | 598.5 | 598.5 | 10.0 | False | None | None | False | None | False | 5985.0 | 0 |
3119350 | 107176 | None | code26 | Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694 confirming to latest amendments 6 2 5 GTP of GROUP a 1 5 sqmm with all lead lifts loading unloading charges including cost and conveyance of all materials labour equipments and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work | m | 27.3 | 27.3 | 200.0 | False | None | None | False | None | False | 5460.0 | 0 |
3119351 | 107176 | None | code27 | Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694 confirming to latest amendments 6 2 5 GTP of GROUP a 2 5 sqmm with all lead lifts loading unloading charges including cost and conveyance of all materials labour equipments and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work | m | 44.1 | 44.1 | 200.0 | False | None | None | False | None | False | 8820.0 | 0 |
3119352 | 107176 | None | code28 | Wiring for lighting power circuit using one of pvc insulated 110v grade stranded aluminium unsheathed wire single core cable in open or concealed system of wiring as per IS 694 1990 6sq mm (P No 3 I No 2 3 21 22 with all lead lifts loading unloading charges including cost and conveyance of all materials labour equipments and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work | m | 96.6 | 96.6 | 200.0 | False | None | None | False | None | False | 19320.0 | 0 |
3119353 | 107176 | None | code29 | Supplying 6A flush type socket and 6 A flush type SP switch either surface flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 P No 5 I No 3 1 21-22 6Amps 3 5 Way with all lead lifts loading unloading charges including cost and conveyance of all materials labour equipments and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work | Each | 154.35 | 154.35 | 15.0 | False | None | None | False | None | False | 2315.25 | 0 |
3119354 | 107176 | None | code30 | Supplying and fixing a drop light using one PBBC bakelite pendent holder PVC insulated twin twisted copper wire of 10 0 3mm length upto 1000mm one of 60 100 watts lamp of 230 volts grade and one of 5 amps bakelite ceiling rose fixed on the existing wooden block of the outlet Group A with all lead lifts loading unloading charges including cost and conveyance of all materials labour equipments and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work | Each | 127.05 | 127.05 | 6.0 | False | None | None | False | None | False | 762.3 | 0 |
3119355 | 107176 | None | code31 | Supplying and fixing PBBC bakelite straight or slant batten holder and wiring with 60w 230 volts lamp Group A with all lead lifts loading unloading charges including cost and conveyance of all materials labour equipments and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work | Each | 92.4 | 92.4 | 20.0 | False | None | None | False | None | False | 1848.0 | 0 |
3119356 | 107176 | None | code32 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws a) 8 6 1 5 with all lead lifts loading unloading charges including cost and conveyance of all materials labour equipments and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work | Each | 91.35 | 91.35 | 8.0 | False | None | None | False | None | False | 730.8 | 0 |
3119357 | 107176 | None | code33 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws a) 10 8 1 5 with all lead lifts loading unloading charges including cost and conveyance of all materials labour equipments and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work | Each | 107.1 | 107.1 | 6.0 | False | None | None | False | None | False | 642.6 | 0 |
3119358 | 107176 | None | code34 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws a) 12 12 2 with all lead lifts loading unloading charges including cost and conveyance of all materials labour equipments and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work | Each | 190.05 | 190.05 | 1.0 | False | None | None | False | None | False | 190.05 | 0 |
3119359 | 107176 | None | code35 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden panel using necessary nuts bolts and washers 32Amps with all lead lifts loading unloading charges including cost and conveyance of all materials labour equipments and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work | Each | 253.05 | 253.05 | 1.0 | False | None | None | False | None | False | 253.05 | 0 |
3119360 | 107176 | None | code36 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON OFF energy cross 3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 P No 13 I No 5 17 6 32 A SP Group A with all lead lifts loading unloading charges including cost and conveyance of all materials labour equipments and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work | Each | 435.75 | 435.75 | 2.0 | False | None | None | False | None | False | 871.5 | 0 |
3119361 | 107176 | None | code37 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON OFF energy cross 3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 P No 13 I No 5 17 6 32 A SP Group A with all lead lifts loading unloading charges including cost and conveyance of all materials labour equipments and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work | Each | 775.95 | 775.95 | 1.0 | False | None | None | False | None | False | 775.95 | 0 |
3119362 | 107176 | None | code38 | Supplying and fixing regular MCB distribution boards on wall wood board flush mounting using required clA bolts nuts etc with provision for fixing suitable type capacity MCB s single phase 3 phase single door with powder coated painting Made out of 14 SWG MS enclosure P No 13 I No5.18 I Single Door a 4Way SP &N with all lead lifts loading unloading charges including cost and conveyance of all materials labour equipments and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work | Each | 1303.05 | 1303.05 | 1.0 | False | None | None | False | None | False | 1303.05 | 0 |
3119363 | 107176 | None | code39 | Supplying fixing wiring earth electrode for grounding conduits I C cutouts and other equipment s on the meter board using 40mm dia 2 90mm thick GI pipe 2 5 mtr long buried in a pit The pit should be filled with equal proportion of salt and charcoal 150mm all round the pipe to complete depth The connection from the pipe to the conduit etc is to be established through GI wire of size as per ISI specification 7 3 3 of IS 732 using 12mm dia bolts nuts washers and check nuts etc the pipe shall have 16 through holes of 12 mm dia with all lead lifts loading unloading charges including cost and conveyance of all materials labour equipments and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work | No | 3685.5 | 3685.5 | 1.0 | False | None | None | False | None | False | 3685.5 | 0 |
3119364 | 107176 | None | code40 | Supplying and Fixing of mm dia class A GI pipe bracket up to 2 Mtrs long bent at suitable angle and fixing to this bracket 1 40 2 40 watts fluorescent tube street light fitting of all capacities to GI or CI or rail or RCC pole wall using suitable clamps bolts and nuts and wiring using suitable capacity wires Using 25mm dia G I Pipe with all lead lifts loading unloading charges including cost and conveyance of all materials labour equipments and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work | Each | 1026.9 | 1026.9 | 6.0 | False | None | None | False | None | False | 6161.4 | 0 |
3119365 | 107176 | None | code41 | Fixing all types and all capacities of fluorescent false ceiling spot light CFL LED fittings indoor on the wall ceiling rafters girders using 23 0 0076 twin twisted PVC insulated wires required Nos of round blocks and clA On wall ceiling Rafter Girders with all lead lifts loading unloading charges including cost and conveyance of all materials labour equipments and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work | Each | 128.1 | 128.1 | 8.0 | False | None | None | False | None | False | 1024.8 | 0 |
3119366 | 107176 | None | code42 | Supplying of 1 1 KV LT UG cable having aluminium conductor PVC insulated extruded inner sheathed galvanised steel strip except 2Cx 10Sq mm wire armoured Confirming to IS-39751990 No of Strip indicated in GTP & extruded PVC outer sheated armoured cable with specified IS 1554 Part 1 1998 & confirming to the attached GTP of GROUP A 62 7 4 GROUP A 2 core 10 sqmm with all lead lifts loading unloading charges including cost and conveyance of all materials labour equipments and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work | m | 91.98 | 91.98 | 200.0 | False | None | None | False | None | False | 18396.0 | 0 |
3119367 | 107176 | None | code43 | Supplying capacitor type ceiling fan complete with down rod blades shackle canopies etc for operation on 230 V 50 cycles Single phase AC supply conforming to ISS 374 1979 and with double ball bearing system 56 Sweep 1400 mm Regular model with all lead lifts loading unloading charges including cost and conveyance of all materials labour equipments and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work | Each | 3182.55 | 3182.55 | 6.0 | False | None | None | False | None | False | 19095.3 | 0 |