3116397 | 107094 | None | code01 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.
(ii) -a) By Mechanical means using dozer
In area of light jungle | Sqm | 412.65 | 412.65 | 11.19 | False | None | None | False | None | False | 4617.5535 | 0 |
3116398 | 107094 | None | code02 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth | Cum | 99.75 | 99.75 | 4370.824 | False | None | None | False | None | False | 435989.694 | 0 |
3116399 | 107094 | None | code03 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 497.7 | 497.7 | 626.64 | False | None | None | False | None | False | 311878.728 | 0 |
3116400 | 107094 | None | code04 | Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2 | Cum | 517.65 | 517.65 | 2139.78 | False | None | None | False | None | False | 1107657.117 | 0 |
3116401 | 107094 | None | code05 | Construction of Granular Sub-Base of required grading as per design mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401
For Grading -V Material | Cum | 2611.35 | 2611.35 | 1215.98 | False | None | None | False | None | False | 3175349.373 | 0 |
3116402 | 107094 | None | code06 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory rollerto achieve the desireddensity. | Cum | 2686.95 | 2686.95 | 960.85 | False | None | None | False | None | False | 2581755.9075 | 0 |
3116403 | 107094 | None | code07 | Providing and laying Bituminous Macadam with 40/60 TPH capacity hot mix plant using crushed aggregates of specified grading premixed with bituminous binder VG-30 @ 3.4% by weight of mix, transported to site, laid over a previously prepared surface with mechanical paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction | Cum | 8044.05 | 8044.05 | 208.88 | False | None | None | False | None | False | 1680241.164 | 0 |
3116404 | 107094 | None | code08 | Providing and applying primer coat with SS1 grade Bitumen Emulsion on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70 kg/m2 using mechanical means. | Sqm | 43.05 | 43.05 | 4177.6 | False | None | None | False | None | False | 179845.68 | 0 |
3116405 | 107094 | None | code09 | KSRRB M500-10. Providing and applying tack coat using 80/100 grade bitumen(VG10) in boiler fitted with spray set distributor at the rate of 0.20 kg per sqm on the existing prepared bituminous surface cleaned with mchancial broom. complete as per specifications. - using bitumen 80/100 on primed surfaces | Sqm | 12.6 | 12.6 | 4177.6 | False | None | None | False | None | False | 52637.76 | 0 |
3116406 | 107094 | None | code10 | Providing and laying Semi Dense Bituminous Concrete with 40/60 TPH capacity hot mix plant batch type using crushed aggregates of specified grading premixed with bituminous binder VG-30 @ 5% by weight of mix and filler, transported to site, laid over a previously prepared surface with mechanical paver finisher to the required grade, level and alignment and rolled as per MoRTH V revision. | Cum | 10659.6 | 10659.6 | 104.44 | False | None | None | False | None | False | 1113288.624 | 0 |
3116407 | 107094 | None | code11 | Providing and erecting direction and place identification retro- reflectorised sign as per IRC:67:2022 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick or Aluminium composite material sheet with overall thickness of 4mm with area not exceeding 0.9 m2 fixed over back support frame of min 35 x 35 x 3mm angle mounted on a mild steel circular pipe 65 NB, firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing | Sqm | 9460.5 | 9460.5 | 8.0 | False | None | None | False | None | False | 75684.0 | 0 |
3116408 | 107094 | None | code12 | Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC:67:2022 made of Class C Type XI retro reflective sheeting fixed over 2 mm thick aluminium sheeting vide clause 801.3, 3mm/4mm thick Aluminium composite material sheet depending on the size of the sign fixed over the back support frame of min 25 x 25 x 3mm angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing.The sign shall be maintained as per section 12 of IRC:67:2022.
60 cm equilateral triangle | Each | 3784.2 | 3784.2 | 9.96 | False | None | None | False | None | False | 37690.632 | 0 |
3116409 | 107094 | None | code13 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)
Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6288.45 | 6288.45 | 6.9937 | False | None | None | False | None | False | 43979.532765 | 0 |
3116410 | 107094 | None | code14 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)
Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6724.2 | 6724.2 | 29.84 | False | None | None | False | None | False | 200650.128 | 0 |
3116411 | 107094 | None | code15 | Addtionalities for Providing shuttering ,centering , Scaffolding | Cum | 512.32 | 512.32 | 29.84 | False | None | None | False | None | False | 15287.6288 | 0 |
3116412 | 107094 | None | code16 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. | Tonne | 90754.65 | 90754.65 | 2.597 | False | None | None | False | None | False | 235689.82605 | 0 |
3116413 | 107094 | None | code17 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. | Cum | 6601.35 | 6601.35 | 2.592 | False | None | None | False | None | False | 17110.6992 | 0 |
3116414 | 107094 | None | code18 | Supplying of Solar Raised Pavement Markers made of polycarbonate molded body with circular shape, solar powered, LED self illumination in active mode, 360 degree illumination and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face in passive mode. The marker shall support a load of 20000 kg tested in accordance to ASTM D 4280. The marker should be resistant to dust and water ingress according to IP 65 standards and should withstand tempertures in the range of 0 C to 70 C. Color of lighting could be provided in red or yellow (amber) as per requirement and typicl frequency of blinking is 1 Hz. There should be current losses of less than 20 microamperes at 2.4 V in sleepcharging mode to enhance the life of the marker and a full charge should provide for a minimum autonomy of 50 hours. The height, width and length of the marker shall not be less than 10 mm x 100 mm x 100 mm. Also, the surface diameter of the marker shall not be less than 100 mm respectively. The weight of the marker shall not exceed 0.5 kg. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive and complete as directed by the engineer | Each | 350.0 | 350.0 | 2984.0 | False | None | None | False | None | False | 1044400.0 | 0 |
3116415 | 107094 | None | code19 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work | Cum | 107.1 | 107.1 | 4374.0 | False | None | None | False | None | False | 468455.4 | 0 |
3116416 | 107094 | None | code20 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)
Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6288.45 | 6288.45 | 364.5 | False | None | None | False | None | False | 2292140.025 | 0 |
3116417 | 107094 | None | code21 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)
Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6724.2 | 6724.2 | 1188.0 | False | None | None | False | None | False | 7988349.6 | 0 |
3116418 | 107094 | None | code22 | Addtionalities for Providing shuttering , centering , Scaffolding | Cum | 512.32 | 512.32 | 1188.0 | False | None | None | False | None | False | 608636.16 | 0 |
3116419 | 107094 | None | code23 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. | Tonne | 90754.65 | 90754.65 | 53.12 | False | None | None | False | None | False | 4820887.008 | 0 |
3116420 | 107094 | None | code24 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work | Cum | 107.1 | 107.1 | 52.72 | False | None | None | False | None | False | 5646.312 | 0 |
3116421 | 107094 | None | code25 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)
Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6288.45 | 6288.45 | 14.16 | False | None | None | False | None | False | 89044.452 | 0 |
3116422 | 107094 | None | code26 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)
M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6639.15 | 6639.15 | 59.16 | False | None | None | False | None | False | 392772.114 | 0 |
3116423 | 107094 | None | code27 | Addtionalities for Providing shuttering , centering , Scaffolding | Cum | 505.84 | 505.84 | 59.16 | False | None | None | False | None | False | 29925.4944 | 0 |
3116424 | 107094 | None | code28 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. | Tonne | 90754.65 | 90754.65 | 4.44 | False | None | None | False | None | False | 402950.646 | 0 |
3116425 | 107094 | None | code29 | Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates a(P.No-17, I.No-2.5.1 Uni SR Vo-1 2023-24) | Cum | 6961.5 | 6961.5 | 3.12 | False | None | None | False | None | False | 21719.88 | 0 |
3116426 | 107094 | None | code30 | Addtionalities for Providing shuttering , centering , Scaffolding | Cum | 530.4 | 530.4 | 3.12 | False | None | None | False | None | False | 1654.848 | 0 |
3116427 | 107094 | None | code31 | Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates a | Cum | 7185.15 | 7185.15 | 15.0 | False | None | None | False | None | False | 107777.25 | 0 |
3116428 | 107094 | None | code32 | Addtionalities for Providing shuttering , centering , Scaffolding | Cum | 547.44 | 547.44 | 15.0 | False | None | None | False | None | False | 8211.6 | 0 |
3116429 | 107094 | None | code33 | Supplying fitting & placing TMT bar reinforcement to super structure complete as per Specifications | Tonne | 108693.9 | 108693.9 | 1.48 | False | None | None | False | None | False | 160866.972 | 0 |
3116430 | 107094 | None | code34 | Decorative light poles Fabricating. supplying and erection of 1 Mtrs long hot dip Gialvanized Conical pole with BSEN 10025 grade S 355 JO steel plate for shaft, 1IS 2062 for base plate with door openingarrangements, including suitable boards, Bakelite sheet for MCBs as per IS specifications suitable to withstand the wind specd of 47 m sec for 11 Mirs pole in double single section and single joint welded per IS 9505 18s 1o178AWS having dimensions bottom 200nmm, top 70 mm with 3mm thick, 2no sof pole The poles should be painted acsthetically using good quality PU auto coat paint. The centre pole should be 3mtr hevght 16smm dia 3mm thick hav ing Imtr perforation from 1 Smtr to 2.Smtr height the poy carbonate pipe housed inside the perforation along with color changing LED visible from all side. The foundation plate should be suitable to fix 2nos of 11 mtr bent at side of this pole. The suitable aluminum head placed at top including PC cover having 7watt LELD Bulb inside suitable base plate and no s ot M 4m longBolts along wth template and necessary arrangements. The pole shallbe Hot dip galvanized in singie dipping with not less than 65 micron as per ASTM-A 123 and 153 etc EOl approved rate. The pole should be as shown in attached picture. | Each | 86578.0 | 86578.0 | 12.0 | False | None | None | False | None | False | 1038936.0 | 0 |
3116431 | 107094 | None | code35 | HDPE/PLB Pipe 50/42 mm CSR(2023-24) I.No. 66.04 (11KV SYSTEM MATERIAL) | Km | 85014.0 | 85014.0 | 0.36 | False | None | None | False | None | False | 30605.04 | 0 |
3116432 | 107094 | None | code36 | Mechanical Means: -In all kinds of soils Depth upto 3m Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. 'PWD Schedule of Rates 2023-2024 Vol No.1, Page No:8, Item No: 1.14.1 | Cum | 102.0 | 102.0 | 27.0 | False | None | None | False | None | False | 2754.0 | 0 |
3116433 | 107094 | None | code37 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates. 'PWD Schedule of Rates 2023-2024 Vol No.1, Page No:17, Item No:2.4.1 | Cum | 6404.0 | 6404.0 | 4.05 | False | None | None | False | None | False | 25936.2 | 0 |
3116434 | 107094 | None | code38 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. 'PWD Schedule of Rates 2023-2024 Vol No.1, Page No:15, Item No:2.2.1 | Cum | 6287.0 | 6287.0 | 9.945 | False | None | None | False | None | False | 62524.215 | 0 |
3116435 | 107094 | None | code39 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. 'PWD Schedule of Rates 2023-2024 Vol No.1, Page No:18, Item No:2.11 | Tonne | 86433.0 | 86433.0 | 0.9945 | False | None | None | False | None | False | 85957.6185 | 0 |
3116436 | 107094 | None | code40 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 a) 4 core 16sqmm
CSR(2023-24) I.No.32.05(11KV SYSTEM MATERIAL) | Km | 141842.0 | 141842.0 | 0.6 | False | None | None | False | None | False | 85105.2 | 0 |
3116437 | 107094 | None | code41 | b) 3.5 core 25sqmm
CSR(2023-24) I.No.32.07(11KV SYSTEM MATERIAL) | Km | 139549.0 | 139549.0 | 0.25 | False | None | None | False | None | False | 34887.25 | 0 |
3116438 | 107094 | None | code42 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as
directed by the departmental staff a) 2.5 to 25 Sqmm
CSR(2021-22) I.No.31.05 (11kv labour ) | Km | 11.88 | 11.88 | 3.25 | False | None | None | False | None | False | 38.61 | 0 |
3116439 | 107094 | None | code43 | b)2.5 to 25 Sqmm
CSR(2021-22) I.No.31.05 (11kv labour ) | Km | 15.5 | 15.5 | 0.25 | False | None | None | False | None | False | 3.875 | 0 |
3116440 | 107094 | None | code44 | Digging of trench of 0.6 m deepx 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete. As per civil SR KSRB 1-2 p-7 a) In ordinary soil
PWDSR(2019-20) page No-41 I.No.6.6.1 | Mtr | 76.0 | 76.0 | 600.0 | False | None | None | False | None | False | 45600.0 | 0 |
3116441 | 107094 | None | code45 | b) Asphalt cutting
PWDSR(2019-20) page No-41 I.No.6.6.4 | Mtr | 113.0 | 113.0 | 50.0 | False | None | None | False | None | False | 5650.0 | 0 |
3116442 | 107094 | None | code46 | c) C.C cutting
PWDSR(2019-20) page No-41 I.No.6.6.5 | Mtr | 205.0 | 205.0 | 50.0 | False | None | None | False | None | False | 10250.0 | 0 |
3116443 | 107094 | None | code47 | Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable. PWDSR(2019-20) page No-41 I.No.6.7 | Mtr | 100.0 | 100.0 | 750.0 | False | None | None | False | None | False | 75000.0 | 0 |
3116444 | 107094 | None | code48 | GI Pipe B - Class as per IS-1239 a) 40mm
CSR(2021-22) I.No.49.04 | Mtr | 295.0 | 295.0 | 100.0 | False | None | None | False | None | False | 29500.0 | 0 |
3116445 | 107094 | None | code49 | b) 65mm
CSR(2021-22) I.No.49.07 | Mtr | 547.0 | 547.0 | 30.0 | False | None | None | False | None | False | 16410.0 | 0 |
3116446 | 107094 | None | code50 | Brass Cable Gland a) 25mm dia
PWDSR(2019-20) page No-42 I.No70.01 | Each | 77.0 | 77.0 | 50.0 | False | None | None | False | None | False | 3850.0 | 0 |
3116447 | 107094 | None | code51 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the follwing sizes a) 16sqmm CSR (2021-22) I.no.64.02 | Each | 3.0 | 3.0 | 625.0 | False | None | None | False | None | False | 1875.0 | 0 |
3116448 | 107094 | None | code52 | b) 25sqmmlong barrel CSR (2021-22) I.no.64.03 | Each | 4.0 | 4.0 | 100.0 | False | None | None | False | None | False | 400.0 | 0 |
3116449 | 107094 | None | code53 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip. PWD SR(2019-20) P.no.40 I.no. 6.3.1 | Mtr | 75.0 | 75.0 | 600.0 | False | None | None | False | None | False | 45000.0 | 0 |
3116450 | 107094 | None | code54 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted
wooden plugs screws 20" x 20" x 2.5" CSR(2021-22) I.no.5.6.6 | Each | 315.0 | 315.0 | 3.75 | False | None | None | False | None | False | 1181.25 | 0 |
3116451 | 107094 | None | code55 | Supplying and fixing hylum plastic sheet 3mm thick with necessary nitches for fixing switches, regulators etc., and fixing on existing wood or metal box using N.F. screws. PWD SR(2021-22) I.no. 3.9 | Sqm | 0.26 | 0.26 | 10000.0 | False | None | None | False | None | False | 2600.0 | 0 |
3116452 | 107094 | None | code56 | Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.14SWG CSR(2021-22) I.No.5.42.1 | Sqm | 0.43 | 0.43 | 100000.0 | False | None | None | False | None | False | 43000.0 | 0 |
3116453 | 107094 | None | code57 | Supplying and fixing of 4 pole power contractor with NO/NC contacts on existing wood /panel board using necessary bolts,nuts,washers and wiring etc., complete with AC 3 rating and as per IS-13947 60-70Amps
CSR(2021-22) I.No.5.13.3 | Each | 4926.0 | 4926.0 | 3.0 | False | None | None | False | None | False | 14778.0 | 0 |
3116454 | 107094 | None | code58 | Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 Amps three phase 4 wire whole current class-1 Accuracy Energy Meter.CSR(2021-22) I.No.5.35 | Each | 5125.0 | 5125.0 | 3.0 | False | None | None | False | None | False | 15375.0 | 0 |
3116455 | 107094 | None | code59 | Supplying and fixing microprocessor based electronic timer(without contact ,Din mounting using necessary bolts,nuts and washers etc.,)3-120sec
CSR(2021-22 I.No.5.47 | Each | 2079.0 | 2079.0 | 3.0 | False | None | None | False | None | False | 6237.0 | 0 |
3116456 | 107094 | None | code60 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. a) 6-32 Amps SP
CSR(2021-22) I.No.5.17.1 | Each | 523.0 | 523.0 | 24.0 | False | None | None | False | None | False | 12552.0 | 0 |
3116457 | 107094 | None | code61 | b) 50-63Amps TPN
CSR(2021-22) I.No.5.17.9 | Each | 2399.0 | 2399.0 | 3.0 | False | None | None | False | None | False | 7197.0 | 0 |
3116458 | 107094 | None | code62 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V up to 300mA sensitivity on existing wood/panel board.63amps 4 pole CSR(2021-22) I.No.5.20.4 | Each | 3058.0 | 3058.0 | 3.0 | False | None | None | False | None | False | 9174.0 | 0 |
3116459 | 107094 | None | code63 | Supplying and fixing angle iron frame work fabricated out of M.S angle iron and M.S flat with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm
CSR(2021-22) I.No.5.41.1 | Mtr | 275.0 | 275.0 | 30.0 | False | None | None | False | None | False | 8250.0 | 0 |
3116460 | 107094 | None | code64 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS:8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100Volts as per IS-694:1990. 2C x 2.5sq.mm CSR(2021-22) I.No.2.5.7 | Mtr | 79.0 | 79.0 | 300.0 | False | None | None | False | None | False | 23700.0 | 0 |
3116461 | 107094 | None | code65 | Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 32mm dia 2.5mm thick CSR(2021-22) item no 1.3.3 | Mtr | 105.0 | 105.0 | 10.0 | False | None | None | False | None | False | 1050.0 | 0 |
3116462 | 107094 | None | code66 | Supplying , fixing, wiring, earth electrode for grounding conduits, I.C cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit…. The pit should be filled with equal proportion of salt and hcarcoal 150 mm all round the pipe to complete depth. the connection from the pipe to the conduit etc., is to be established through GI pipe of sizw as per ISI specification 7.3.3 of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia. PWDSR(2019-20) page No-40 I.No.6.1 | No | 2999.7 | 2999.7 | 4.0 | False | None | None | False | None | False | 11998.8 | 0 |
3116463 | 107094 | None | code67 | Supplying and fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts,bolts and washers 100Amps
CSR(2021-22) I.No.5.7.4 | No | 650.0 | 650.0 | 6.0 | False | None | None | False | None | False | 3900.0 | 0 |
3116464 | 107094 | None | code68 | Supplying of switch disconnector fuse unit (TPN) HRC type (but without HRC fuses). With AC-23A duty and as per IS-13947 125 Amps CSR(2021-220) I.No5.8.3 | Each | 5292.0 | 5292.0 | 3.0 | False | None | None | False | None | False | 15876.0 | 0 |
3116465 | 107094 | None | code69 | Supplying and fixing LED type panel board indicating lamp with required colour suitable for 220v A.C 50 Hz 12/24v D.C CSR(2021-220) I.No.5.38 | No | 464.0 | 464.0 | 6.0 | False | None | None | False | None | False | 2784.0 | 0 |
3116466 | 107094 | None | code70 | Supplying ,fixing and wiring 0 to 100 amps direct reading AC analog type Ammeter
CSR(2021-22) I.No.5.25 | Each | 472.0 | 472.0 | 6.0 | False | None | None | False | None | False | 2832.0 | 0 |
3116467 | 107094 | None | code71 | Supplying PVC/GI flexible conduit pipe 25 mm dia fixing on furface over inverted taperd wooden plugs or phill plugs or rawl plugs and clamped using heavy guage saddles at an interval of 300mm using NF screws and on either and of the pipe terminated completely.25mm CSR(2021-22) item no 1.9.2 | Mtr | 31.0 | 31.0 | 3.0 | False | None | None | False | None | False | 93.0 | 0 |
3116468 | 107094 | None | code72 | Supplying fixing and wiring 0 to 600 volts 96x96mm AC voltmeter on existing panel/wood board.
CSR(2021-22) I.No.5.22 | Each | 407.0 | 407.0 | 3.0 | False | None | None | False | None | False | 1221.0 | 0 |
3116469 | 107094 | None | code73 | Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 100Amps 4x30x6mm Aluminium Strips CSR(2021-22) I.No.5.40.1 | Mtr | 2214.0 | 2214.0 | 3.7 | False | None | None | False | None | False | 8191.8 | 0 |
3116470 | 107094 | None | code74 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws,bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics) FOUR POLE 100Amps 25kA.CSR(2021-22) I.No.5.14.7 | Each | 8265.0 | 8265.0 | 3.0 | False | None | None | False | None | False | 24795.0 | 0 |
3116471 | 107094 | None | code75 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm
CSR(2021-22) I.No. 2.3.3 | Mtr | 40.0 | 40.0 | 625.0 | False | None | None | False | None | False | 25000.0 | 0 |
3116472 | 107094 | None | code76 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70 maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K IP66 optical and electrical compartment impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection Min 5KV along with Over voltage Overload, short circuit miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50 60Hz application. Compliance to IS 10322IEC 60598, LM 79 LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiency 1301m w, nominal CRI 75. Luminaire manufacturer should have in house facility accredited by NABL CPRI any Government certified agency Design & Development facility certified by ISO 9001 2008. Housing with supplier word mark name shall be Engraved Embossing on the die cast housing Body part. Warranty of 2 Years against any manufacturing defect LED Streetlight 150 W 14705.00 CSR 2021-22 I.No. 11.8.6 | No | 5955.0 | 5955.0 | 66.0 | False | None | None | False | None | False | 393030.0 | 0 |