1710504241000 | 0 | None | None | Other Works | REMOVING OF JUNGAL,LEVELING OF LAND, MARKING OF SITE, FOR APPROVED LAY-OUT, CONSTRUCTION OF ESSENTIAL ROAD, DRAIN, PROVIDING ELECTRIC POLE AND STREET LIGHT AT HAMALA HOUSE LAYOUT OFBORAGONDANAHALLI VILLAGE H GIRIYAPURA SYR. NO. 6/1 OF APMC DAVANAGERE LIMITS UNDER UNDER ANNUAL ACTION PLAN 2024-25 | 17457653.28 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3095288 | 106419 | None | code01 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil complete the work with all leads & lift complete as per specification and as directed by the engineer of the work. | Sqm | 393.0 | 393.0 | 219.79 | False | None | None | False | None | False | 86377.47 | 0 | 3095289 | 106419 | None | code02 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work with all leads & lift complete as per specification and as directed by the engineer of the work. | Cum | 102.0 | 102.0 | 13582.04 | False | None | None | False | None | False | 1385368.08 | 0 | 3095290 | 106419 | None | code03 | Construction of Embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded with desired compaction. complete the work with all leads & lift complete as per specification and as directed by the engineer of the work. | Cum | 119.0 | 119.0 | 13086.0 | False | None | None | False | None | False | 1557234.0 | 0 | 3095291 | 106419 | None | code04 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of our,rolling,water,all materials,usage& all other appurtenaces required to complete the work with all leads & lift complete as per specification and as directed by the engineer of the work. | Cum | 474.0 | 474.0 | 7155.78 | False | None | None | False | None | False | 3391839.72 | 0 | 3095292 | 106419 | None | code05 | Reinforced cement concrete M15 grade boundary pillars of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting complete the work with all leads & lift complete as per specification and as directed by the engineer of the work. | Nos | 748.0 | 748.0 | 750.0 | False | None | None | False | None | False | 561000.0 | 0 | 3095293 | 106419 | None | code06 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete the work with all leads & lift complete as per specification and as directed by the engineer of the work. | Sqm | 115.0 | 115.0 | 300.0 | False | None | None | False | None | False | 34500.0 | 0 | 3095294 | 106419 | None | code07 | Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete the work with all leads & lift complete as per specification and as directed by the engineer of the work. | cm | 4.0 | 4.0 | 5990.0 | False | None | None | False | None | False | 23960.0 | 0 | 3095295 | 106419 | None | code08 | Loosening , leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment , scarified to a depth of 150 mm , mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction complete the work with all leads & lift complete as per specification and as directed by the engineer of the work.. | Cum | 105.0 | 105.0 | 1158.26 | False | None | None | False | None | False | 121617.3 | 0 | 3095296 | 106419 | None | code09 | Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2 complete the work with all leads & lift complete as per specification and as directed by the engineer of the work. | Cum | 493.0 | 493.0 | 435.82 | False | None | None | False | None | False | 214859.26 | 0 | 3095297 | 106419 | None | code10 | Construction of Granular Sub-BaseFor Grading -V Material of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 complete the work with all leads & lift complete as per specification and as directed by the engineer of the work. | Cum | 2359.0 | 2359.0 | 76.73 | False | None | None | False | None | False | 181006.07 | 0 | 3095298 | 106419 | None | code11 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in m3 2,394.00uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density | Cum | 2559.0 | 2559.0 | 378.55 | False | None | None | False | None | False | 968709.45 | 0 | 3095299 | 106419 | None | code12 | Providing and applying primer coat with SS1 grade Bitumen Emulsion on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70 kg/m2 using mechanical means complete the work with all leads & lift complete as per specification and as directed by the engineer of the work. | Sqm | 41.0 | 41.0 | 3274.03 | False | None | None | False | None | False | 134235.23 | 0 | 3095300 | 106419 | None | code13 | Providing and laying Dense Graded Bituminous Macadam with 100 TPH capacity hot mix plant batch type using crushed aggregates of specified grading, premixed with bituminous binder VG-30, @ 4.0 per cent by weight of total mix and filler, transporting the hot mix to work site, laying with mechanical paver finisher to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH specification clause No. 505 complete the work with all leads & lift complete as per specification and as directed by the engineer of the work. | Cum | 8692.0 | 8692.0 | 163.7 | False | None | None | False | None | False | 1422880.4 | 0 | 3095301 | 106419 | None | code14 | Providing and applying tack coat with RS1 Bituminous Emulsion using emulsion pressure distributor at the rate of 0.20 kg/m2 on the prepared bituminous surface cleaned with mechanical broom | Sqm | 12.0 | 12.0 | 3274.03 | False | None | None | False | None | False | 39288.36 | 0 | 3095302 | 106419 | None | code15 | Providing and laying Semi Dense Bituminous Concrete with 40/60 TPH capacity hot mix plant batch type using crushed aggregates of specified grading premixed with bituminous binder VG-30 @ 5% by weight of mix and filler, transported to site, laid over a previously prepared surface with mechanical paver finisher to the required grade, level and alignment and rolled as per MoRTH V revision. complete the work with all leads & lift complete as per specification and as directed by the engineer of the work. | Cum | 10152.0 | 10152.0 | 81.85 | False | None | None | False | None | False | 830941.2 | 0 | 3095303 | 106419 | None | code16 | Providing and laying in position Cement Concrete Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work with all leads & lift complete as per specification and as directed by the engineer of the work. | Cum | 5664.0 | 5664.0 | 83.32 | False | None | None | False | None | False | 471924.48 | 0 | 3095304 | 106419 | None | code17 | Providing and laying in position Cement Concrete M25 Design Mix Using 25 mm nominal size graded crushed coarse aggregates for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work with all leads & lift complete as per specification and as directed by the engineer of the work. | Cum | 6652.8 | 6652.8 | 46.09 | False | None | None | False | None | False | 306627.552 | 0 | 3095305 | 106419 | None | code18 | Providing and laying in position Cement Concrete M25 Design Mix Using 25 mm nominal size graded crushed coarse aggregates for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. | Cum | 8553.6 | 8553.6 | 82.88 | False | None | None | False | None | False | 708922.368 | 0 | 3095306 | 106419 | None | code19 | Providing and laying in position Reinforced cement concrete M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other complete the work with all leads & lift complete as per specification and as directed by the engineer of the work. | Cum | 6652.8 | 6652.8 | 53.77 | False | None | None | False | None | False | 357721.056 | 0 | 3095307 | 106419 | None | code20 | Providing and laying in position Reinforced cement concrete M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other complete the work with all leads & lift complete as per specification and as directed by the engineer of the work. | Cum | 7603.2 | 7603.2 | 25.62 | False | None | None | False | None | False | 194793.984 | 0 | 3095308 | 106419 | None | code21 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. | MT | 79011.0 | 79011.0 | 24.85 | False | None | None | False | None | False | 1963423.35 | 0 | 3095309 | 106419 | None | code22 | Fabricating, supplying and erection of 10 m - Top 70 mm and Bottom 175 mm dia long hot dip Galvanized Octagonal hot dip Pole with BSEN 10025 grade S355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for 10mtr Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom 175 mm , top 70mm with 3 mm thick, suitable base plate and 4Nos of ..... long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc., (excluding foundation) as per drawing appended. complete the work with all leads & lift complete as per specification and as directed by the engineer of the work. | Each | 21500.0 | 21500.0 | 46.0 | False | None | None | False | None | False | 989000.0 | 0 | 3095310 | 106419 | None | code23 | Supplying, and fixing of Hot dip Galvanized M.S.Bracket suitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. Single Arm Bracket with 1500 mm Standard 40/50 mm dia. complete the work with all leads & lift complete as per specification and as directed by the engineer of the work. | Each | 2100.0 | 2100.0 | 46.0 | False | None | None | False | None | False | 96600.0 | 0 | 3095311 | 106419 | None | code24 | Supply of 90 Watts LED streetlight with pressure die cast aluminum housing body with optimal heat sink for better thermal dissipation. Diffuser with injection moulded & is made of polycarbonate material with high transmission indes delivering superior light output . Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70% CCT 5500K, IP 66 optical and electrical compartment & impact rsistance of complete luminare IK08. power Factor 0.9 with mains current should not be greater than 0.1A to 0.7A & Surge Protection-Min 4KV along with over voltage /Overload, short circuit/miswiring protection. Compatible for pole mounting with outer dia of 40 mm to 50 mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60 Hz application. Over load & short circuit protection ensures reliable operation in spite of problem in output side. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL aproved MCPCB Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools . LED Light fixture with 65 W System power consumption. LED Efficiency 130lm/w at 1W & Fixture Efficiency 80lm with nominal CRI 75. Luminaire manufacturer should have in house facility accredited by NABL/CPRI & any Government ISO 9001:2008. Housing with supplier word mark/name shall be Engraved/Embossing on the die cast housing/Body part. Warrantly of 2 years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED source manufacture & Cree/Nichia/ Lumileds/Osram make LED Source. complete the work with all leads & lift complete as per specification and as directed by the engineer of the work. | Each | 8860.0 | 8860.0 | 46.0 | False | None | None | False | None | False | 407560.0 | 0 | 3095312 | 106419 | None | code25 | Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires. complete the work with all leads & lift complete as per specification and as directed by the engineer of the work. | Each | 162.0 | 162.0 | 46.0 | False | None | None | False | None | False | 7452.0 | 0 | 3095313 | 106419 | None | code26 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including etting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m. complete the work with all leads & lift complete as per specification and as directed by the engineer of the work. | cm | 102.0 | 102.0 | 16.56 | False | None | None | False | None | False | 1689.12 | 0 | 3095314 | 106419 | None | code27 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates. complete the work with all leads & lift complete as per specification and as directed by the engineer of the work. | cm | 5664.0 | 5664.0 | 1.66 | False | None | None | False | None | False | 9402.24 | 0 | 3095315 | 106419 | None | code28 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. complete the work with all leads & lift complete as per specification and as directed by the engineer of the work. | cm | 6287.0 | 6287.0 | 19.87 | False | None | None | False | None | False | 124922.69 | 0 | 3095316 | 106419 | None | code29 | Supplying and drawing of 2C x 4Sqmm Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS:8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100Volts as per IS-694:1990. complete the work with all leads & lift complete as per specification and as directed by the engineer of the work. | Mtr | 123.0 | 123.0 | 600.0 | False | None | None | False | None | False | 73800.0 | 0 | 3095317 | 106419 | None | code30 | Fabricating,supplying,and mounting of MS automatic street light control box of size 22,000 sqcm MS Box with following component, 9000 sqcm hylum sheet, 4 mtrs of angle iron, 1 no' Single phase Energy Meter, 1mtr 100 Amps Bus Bar, 2 No' of 6-32Amps DP , 1 no' 6-32Amps SP MCB, 1 no's of 32Amps Fuse Channel,1 no' Microprocessor based Electronic timer, 1 no' of 4 pole 32Amps NO/NC Contactor and etc. Annexure - 3 | No | 30642.0 | 30642.0 | 2.0 | False | None | None | False | None | False | 61284.0 | 0 | 3095318 | 106419 | None | code31 | 1.1 kV, 25 Sqmm, 3.5 Core, (12 GI Strips 4 x 0.8 mm) XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. (To Link Streetlight Poles) complete the work with all leads & lift complete as per specification and as directed by the engineer of the work | Km | 139549.0 | 139549.0 | 2.0 | False | None | None | False | None | False | 279098.0 | 0 | 3095319 | 106419 | None | code32 | Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. All kinds of soils. Depth upto 1.50 m(1800mtrs length x 0.5Mtr width x 0.7Mtr depth = 700Cmt). complete the work with all leads & lift complete as per specification and as directed by the engineer of the work. | cm | 262.0 | 262.0 | 630.0 | False | None | None | False | None | False | 165060.0 | 0 | 3095320 | 106419 | None | code33 | Laying of 2.5 to 25 Sqmm LT UG cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. complete the work with all leads & lift complete as per specification and as directed by the engineer of the work. | Km | 20886.0 | 20886.0 | 2.0 | False | None | None | False | None | False | 41772.0 | 0 | 3095321 | 106419 | None | code34 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications. (1800mtrs length x 0.5Mtr width x 0.7Mtr depth = 15Cmt). complete the work with all leads & lift complete as per specification and as directed by the engineer of the work. | cm | 160.0 | 160.0 | 630.0 | False | None | None | False | None | False | 100800.0 | 0 | 3095322 | 106419 | None | code35 | Straight Through Jointing Kit Suitable for 1.1 kV Class 70 Sqmm, 3.5/4 Core LTUG Cable as per IS-13573. complete the work with all leads & lift complete as per specification and as directed by the engineer of the work. | Set | 1055.0 | 1055.0 | 4.0 | False | None | None | False | None | False | 4220.0 | 0 | 3095323 | 106419 | None | code36 | Straight Through Jointing Kit Suitable for 1.1 kV Class 25 Sqmm, 4 Core LTUG Cable as per IS-13573. complete the work with all leads & lift complete as per specification and as directed by the engineer of the work. | Set | 750.0 | 750.0 | 30.0 | False | None | None | False | None | False | 22500.0 | 0 | 3095324 | 106419 | None | code37 | HDPE/PLB Pipe 50/42 mm. complete the work with all leads & lift complete as per specification and as directed by the engineer of the work. | Km | 85014.0 | 85014.0 | 1.35 | False | None | None | False | None | False | 114768.9 | 0 | 3095325 | 106419 | None | code38 | Aluminium End Terminal (Lug) 25 Sqmm. complete the work with all leads & lift complete as per specification and as directed by the engineer of the work. | No | 3.0 | 3.0 | 165.0 | False | None | None | False | None | False | 495.0 | 0 |
|