3099861 | 106626 | None | code01 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. (PWD DSR 2023-2024 IT NO. 1.12, PNO.8) | Cum | 99.75 | 99.75 | 75.0 | False | None | None | False | None | False | 7481.25 | 0 |
3099862 | 106626 | None | code02 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical pecifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work (PWD DSR 2023-2024 It. No. 1.14.1, P. No. 8 | Cum | 107.1 | 107.1 | 269.41 | False | None | None | False | None | False | 28853.811 | 0 |
3099863 | 106626 | None | code03 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting
& stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.(PWD DSR 2023-2024 IT NO.1.15.2, PNO.9) Depth exceeding 1.5m, but not exceeding 3 m | Cum | 446.25 | 446.25 | 86.34 | False | None | None | False | None | False | 38529.225 | 0 |
3099864 | 106626 | None | code04 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. Lindane 20% E.C. 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. (PWD DSR 2023-2024 It. No. 4.1, P. No. 5) | Sqm | 123.9 | 123.9 | 356.32 | False | None | None | False | None | False | 44148.048 | 0 |
3099865 | 106626 | None | code05 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates (PWD DSR 2023-2024 IT NO. 2.1.2, PNO.15) | Cum | 5947.2 | 5947.2 | 37.93 | False | None | None | False | None | False | 225577.296 | 0 |
3099866 | 106626 | None | code06 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : (PWD DSR 2023-2024 It. No. 5.1.1, P. No. 9) | Cum | 5891.55 | 5891.55 | 22.82 | False | None | None | False | None | False | 134445.171 | 0 |
3099867 | 106626 | None | code07 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregate (PWD DSR 2023-2024 IT NO. 2.1.4, PNO.15) | Cum | 6527.85 | 6527.85 | 41.3097 | False | None | None | False | None | False | 269663.525145 | 0 |
3099868 | 106626 | None | code08 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD DSR 2023-2024 IT. NO. 2.4.3, Pg.16) | Cum | 6652.8 | 6652.8 | 93.52 | False | None | None | False | None | False | 622169.856 | 0 |
3099869 | 106626 | None | code09 | Formwork for Foundation 8% of finised rate of concrete | Cum | 532.22 | 532.22 | 93.52 | False | None | None | False | None | False | 49773.2144 | 0 |
3099870 | 106626 | None | code10 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD DSR 2023-2024 IT. NO. 2.5.2, Pg.-16) Column | Cum | 7185.15 | 7185.15 | 24.0 | False | None | None | False | None | False | 172443.6 | 0 |
3099871 | 106626 | None | code11 | Column Formwork for Columns & piers 70% of finised rate of concrete | Cum | 5029.6 | 5029.6 | 24.0 | False | None | None | False | None | False | 120710.4 | 0 |
3099872 | 106626 | None | code12 | Plinth Beam | Cum | 7185.15 | 7185.15 | 15.84 | False | None | None | False | None | False | 113812.776 | 0 |
3099873 | 106626 | None | code13 | Formwork for Beams & Lintels 50% of finised rate of concrete | Cum | 3592.57 | 3592.57 | 15.84 | False | None | None | False | None | False | 56906.3088 | 0 |
3099874 | 106626 | None | code14 | Lintel | Cum | 7185.15 | 7185.15 | 4.97 | False | None | None | False | None | False | 35710.1955 | 0 |
3099875 | 106626 | None | code15 | Formwork for Beams & Lintels 60% of finised rate of concrete | Cum | 4311.09 | 4311.09 | 4.97 | False | None | None | False | None | False | 21426.1173 | 0 |
3099876 | 106626 | None | code16 | Roof Beam | Cum | 7185.15 | 7185.15 | 18.142 | False | None | None | False | None | False | 130352.9913 | 0 |
3099877 | 106626 | None | code17 | Formwork for Beams & Lintels 60% of finised rate of concrete | Cum | 4311.09 | 4311.09 | 18.142 | False | None | None | False | None | False | 78211.79478 | 0 |
3099878 | 106626 | None | code18 | Roof Slab | Cum | 7185.15 | 7185.15 | 54.26 | False | None | None | False | None | False | 389866.239 | 0 |
3099879 | 106626 | None | code19 | Formwork for Roof 50% of finised rate of concrete | Cum | 3592.57 | 3592.57 | 54.26 | False | None | None | False | None | False | 194932.8482 | 0 |
3099880 | 106626 | None | code20 | Stair | Cum | 7185.15 | 7185.15 | 4.65 | False | None | None | False | None | False | 33410.9475 | 0 |
3099881 | 106626 | None | code21 | Formwork for stair 50% of finised rate of concrete | Cum | 3592.57 | 3592.57 | 4.65 | False | None | None | False | None | False | 16705.4505 | 0 |
3099882 | 106626 | None | code22 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD DSR 2023-2024 IT. NO. 2.5.2, Pg.-16) | Cum | 7185.15 | 7185.15 | 0.2 | False | None | None | False | None | False | 1437.03 | 0 |
3099883 | 106626 | None | code23 | Formwork for chejja 45% of finised rate of concrete | Cum | 3233.31 | 3233.31 | 0.2 | False | None | None | False | None | False | 646.662 | 0 |
3099884 | 106626 | None | code24 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification (PWD DSR 2021-2022 IT NO. 2.11.A, PNO. 18) | Tonne | 93930.0 | 93930.0 | 27.5 | False | None | None | False | None | False | 2583075.0 | 0 |
3099885 | 106626 | None | code25 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m..(PWD DSR 2023-2024 IT NO. 1.9, PNO. 7) | Cum | 279.3 | 279.3 | 208.58 | False | None | None | False | None | False | 58256.394 | 0 |
3099886 | 106626 | None | code26 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m..(PWD DSR 2023-2024 IT NO. 1.11, PNO. 7) | Cum | 454.65 | 454.65 | 265.64 | False | None | None | False | None | False | 120773.226 | 0 |
3099887 | 106626 | None | code27 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. (PWD DSR 2023-2024 It. No. 6.8, P. No. 14) | Cum | 8367.45 | 8367.45 | 98.06 | False | None | None | False | None | False | 820512.147 | 0 |
3099888 | 106626 | None | code28 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.(PWD DSR 2023-2024 It. No. 6.14, P. No. 14) | Sqm | 1113.0 | 1113.0 | 54.2325 | False | None | None | False | None | False | 60360.7725 | 0 |
3099889 | 106626 | None | code29 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (PWD DSR 2023-2024 IT NO. 2.1.4, PNO.15) | Cum | 6527.85 | 6527.85 | 0.93 | False | None | None | False | None | False | 6070.9005 | 0 |
3099890 | 106626 | None | code30 | Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm (PWD DSR 2023-2024 It. no. 9.12.2, p.no. 60) | Sqm | 1202.25 | 1202.25 | 275.74 | False | None | None | False | None | False | 331508.415 | 0 |
3099891 | 106626 | None | code31 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. (PWD DSR 2023-2024 It. no. 9.24, p.no. 63) | Sqm | 2994.6 | 2994.6 | 90.35 | False | None | None | False | None | False | 270562.11 | 0 |
3099892 | 106626 | None | code32 | Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding for Bathrooms: Toilet: Chemically exposed areas and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) with Acid and alkali resistant tile (PWD DSR 2023-2024 It. No. 9.7.1., P. No. 59) | Sqm | 1308.3 | 1308.3 | 12.86 | False | None | None | False | None | False | 16824.738 | 0 |
3099893 | 106626 | None | code33 | Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding for Bathrooms: Toilet: Chemically exposed areas and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) with Acid and alkali resistant tile (PWD DSR 2023-2024 It. No. 9.7.2., P. No. 59) | Sqm | 1323.0 | 1323.0 | 59.87 | False | None | None | False | None | False | 79208.01 | 0 |
3099894 | 106626 | None | code34 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD DSR 2023-2024 ITEM NO. 8.2.1 P.NO. 41) | Sqm | 309.75 | 309.75 | 59.87 | False | None | None | False | None | False | 18544.7325 | 0 |
3099895 | 106626 | None | code35 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD DSR 2023-2024 ITEM NO. 8.10 P.NO. 43) enternal | Sqm | 221.55 | 221.55 | 419.02 | False | None | None | False | None | False | 92833.881 | 0 |
3099896 | 106626 | None | code36 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD DSR 2023-2024 ITEM NO. 8.10 P.NO. 43) external | Sqm | 221.55 | 221.55 | 65.607 | False | None | None | False | None | False | 14535.23085 | 0 |
3099897 | 106626 | None | code37 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(PWD DSR 2023-2024 ITEM NO. 8.5.2 P.NO. 42) | Sqm | 366.45 | 366.45 | 883.506 | False | None | None | False | None | False | 323760.7737 | 0 |
3099898 | 106626 | None | code38 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge..(2023-2024 ITEM NO. 8.51 P.NO. 50) | Sqm | 105.0 | 105.0 | 1302.52 | False | None | None | False | None | False | 136764.6 | 0 |
3099899 | 106626 | None | code39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge (2023-2024 ITEM NO. 8.39 P.NO. 48) | Sqm | 133.35 | 133.35 | 1302.52 | False | None | None | False | None | False | 173691.042 | 0 |
3099900 | 106626 | None | code40 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. (PWD DSR 2023-2024 It. No. 8.8, P. No.42) | Sqm | 389.55 | 389.55 | 463.156 | False | None | None | False | None | False | 180422.4198 | 0 |
3099901 | 106626 | None | code41 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(PWD DSR 2023-2024 It. No. 8.30, P. No.46) | Sqm | 182.7 | 182.7 | 528.763 | False | None | None | False | None | False | 96605.0001 | 0 |
3099902 | 106626 | None | code42 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. (PWD DSR 2023-2024 It. No. 12.12, P. No.99) | Cum | 130412.1 | 130412.1 | 0.24 | False | None | None | False | None | False | 31298.904 | 0 |
3099903 | 106626 | None | code43 | Clamps - MS (SL.NO 541) | Nos | 58.8 | 58.8 | 24.0 | False | None | None | False | None | False | 1411.2 | 0 |
3099904 | 106626 | None | code44 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.30 mm thick both side commercial (PWD DSR 2023-2024 It. No. 12.57.3, P. No.104) | Sqm | 3155.25 | 3155.25 | 11.76 | False | None | None | False | None | False | 37105.74 | 0 |
3099905 | 106626 | None | code45 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.(PWD DSR 2023-2024 It. No. 12.60, P. No.105) | Sqm | 1104.6 | 1104.6 | 4.0 | False | None | None | False | None | False | 4418.4 | 0 |
3099906 | 106626 | None | code46 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD DSR 2023-2024 It. No. 8.41, P. No.48) | Sqm | 175.35 | 175.35 | 11.76 | False | None | None | False | None | False | 2062.116 | 0 |
3099907 | 106626 | None | code47 | Providing Teak wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. (PWD DSR 2021-2022 It. No. 12.10, P. No.97) | Cum | 247431.45 | 247431.45 | 0.22 | False | None | None | False | None | False | 54434.919 | 0 |
3099908 | 106626 | None | code48 | Clamps - MS (SL.NO 541) | Nos | 58.8 | 58.8 | 6.0 | False | None | None | False | None | False | 352.8 | 0 |
3099909 | 106626 | None | code49 | Providing and fixing in position fully panelled Teak wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) (PWD DSR 2021-2022 It. No. 12.14, P. No.98) | Sqm | 9800.7 | 9800.7 | 6.0 | False | None | None | False | None | False | 58804.2 | 0 |
3099910 | 106626 | None | code50 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.(PWD DSR 2023-2024 It. No. 12.60, P. No.105) | Nos | 1104.6 | 1104.6 | 1.0 | False | None | None | False | None | False | 1104.6 | 0 |
3099911 | 106626 | None | code51 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: (PWD DSR 2023-2024 It. No. 8.82, P. No.54) | Sqm | 710.85 | 710.85 | 13.5 | False | None | None | False | None | False | 9596.475 | 0 |
3099912 | 106626 | None | code52 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 100mm (PWD DSR 2023-2024 It. No. 12.93.1, P. No.111) | Mtr | 737.1 | 737.1 | 31.4 | False | None | None | False | None | False | 23144.94 | 0 |
3099913 | 106626 | None | code53 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum (PWD DSR 2023-2024 It. No. 12.94.1, P. No.112) 30 mm thickness | Sqm | 3659.25 | 3659.25 | 10.71 | False | None | None | False | None | False | 39190.5675 | 0 |
3099914 | 106626 | None | code54 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (PWD DSR 2023-2024 It. No. 12.90, P. No.110) | Sqm | 7070.7 | 7070.7 | 42.41 | False | None | None | False | None | False | 299868.387 | 0 |
3099915 | 106626 | None | code55 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(PWD DSR 2023-2024 It. No. 11.28, P. No.85) | Kgs | 593.25 | 593.25 | 116.4 | False | None | None | False | None | False | 69054.3 | 0 |
3099916 | 106626 | None | code56 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat withapproved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. (PWD DSR 2023-2024 It. No. 11.34B, P. No.86) | Kgs | 192.15 | 192.15 | 890.81 | False | None | None | False | None | False | 171169.1415 | 0 |
3099917 | 106626 | None | code57 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover
including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (PWD DSR 2023-2024 It. No. 11.6.1, P. No.78) | Sqm | 2764.65 | 2764.65 | 16.5 | False | None | None | False | None | False | 45616.725 | 0 |
3099918 | 106626 | None | code58 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD DSR 2023-2024 It. No. 8.41, P. No.48) | Sqm | 175.35 | 175.35 | 147.29 | False | None | None | False | None | False | 25827.3015 | 0 |
3099919 | 106626 | None | code59 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. (PWD DSR 2023-2024 It. No. 10.2, P. No.69) | Mtr | 344.4 | 344.4 | 50.4 | False | None | None | False | None | False | 17357.76 | 0 |
3099920 | 106626 | None | code60 | Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (PWD DSR 2023-2024 It. No. 9.25, P. No.63) | Sqm | 840.0 | 840.0 | 9.0 | False | None | None | False | None | False | 7560.0 | 0 |
3099921 | 106626 | None | code61 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD DSR 2023-2024 IT. NO. 2.5.2, Pg.-16) Column | Cum | 7257.0 | 7257.0 | 15.55 | False | None | None | False | None | False | 112846.35 | 0 |
3099922 | 106626 | None | code62 | Formwork for Columns & piers 70% of finised rate of concrete | Cum | 5079.9 | 5079.9 | 15.55 | False | None | None | False | None | False | 78992.445 | 0 |
3099923 | 106626 | None | code63 | Lintel | Cum | 7257.0 | 7257.0 | 4.476 | False | None | None | False | None | False | 32482.332 | 0 |
3099924 | 106626 | None | code64 | Formwork for Beams & Lintels 60% of finised rate of concrete | Cum | 4354.2 | 4354.2 | 4.476 | False | None | None | False | None | False | 19489.3992 | 0 |
3099925 | 106626 | None | code65 | Roof Beam | Cum | 7257.0 | 7257.0 | 18.09 | False | None | None | False | None | False | 131279.13 | 0 |
3099926 | 106626 | None | code66 | Formwork for Beams & Lintels 60% of finised rate of concrete | Cum | 4354.2 | 4354.2 | 18.09 | False | None | None | False | None | False | 78767.478 | 0 |
3099927 | 106626 | None | code67 | Roof Slab | Cum | 7257.0 | 7257.0 | 56.412 | False | None | None | False | None | False | 409381.884 | 0 |
3099928 | 106626 | None | code68 | Formwork for Roof 50% of finised rate of concrete | Cum | 3628.5 | 3628.5 | 56.412 | False | None | None | False | None | False | 204690.942 | 0 |
3099929 | 106626 | None | code69 | Stair | Cum | 7257.0 | 7257.0 | 4.38 | False | None | None | False | None | False | 31785.66 | 0 |
3099930 | 106626 | None | code70 | Formwork for stair 50% of finised rate of concrete | Cum | 3628.5 | 3628.5 | 4.38 | False | None | None | False | None | False | 15892.83 | 0 |
3099931 | 106626 | None | code71 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD DSR 2023-2024 IT. NO. 2.5.2, Pg.-16) | Cum | 7257.0 | 7257.0 | 1.61 | False | None | None | False | None | False | 11683.77 | 0 |
3099932 | 106626 | None | code72 | Formwork for chejja 45% of finised rate of concrete | Cum | 3265.65 | 3265.65 | 1.61 | False | None | None | False | None | False | 5257.6965 | 0 |
3099933 | 106626 | None | code73 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification (PWD DSR 2021-2022 IT NO. 2.11.A, PNO. 18) | Tonne | 94869.14 | 94869.14 | 15.35 | False | None | None | False | None | False | 1456241.299 | 0 |
3099934 | 106626 | None | code74 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. (PWD DSR 2023-2024 It. No. 6.8, P. No. 14) | Cum | 8451.12 | 8451.12 | 104.07 | False | None | None | False | None | False | 879508.0584 | 0 |
3099935 | 106626 | None | code75 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.(PWD DSR 2023-2024 It. No. 6.14, P. No. 14) | Sqm | 1124.12 | 1124.12 | 34.92 | False | None | None | False | None | False | 39254.2704 | 0 |
3099936 | 106626 | None | code76 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (PWD DSR 2023-2024 IT NO. 2.1.4, PNO.15) | Cum | 6593.12 | 6593.12 | 4.46 | False | None | None | False | None | False | 29405.3152 | 0 |
3099937 | 106626 | None | code77 | Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm (PWD DSR 2023-2024 It. no. 9.12.2, p.no. 60) | Sqm | 1214.27 | 1214.27 | 293.2 | False | None | None | False | None | False | 356023.964 | 0 |
3099938 | 106626 | None | code78 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. (PWD DSR 2023-2024 It. no. 9.24, p.no. 63) | Sqm | 3024.54 | 3024.54 | 55.6 | False | None | None | False | None | False | 168164.424 | 0 |
3099939 | 106626 | None | code79 | Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding for Bathrooms: Toilet: Chemically exposed areas and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) with Acid and alkali resistant tile (PWD DSR 2023-2024 It. No. 9.7.1., P. No. 59) | Sqm | 1321.38 | 1321.38 | 10.61 | False | None | None | False | None | False | 14019.8418 | 0 |
3099940 | 106626 | None | code80 | Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding for Bathrooms: Toilet: Chemically exposed areas and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) with Acid and alkali resistant tile (PWD DSR 2023-2024 It. No. 9.7.2., P. No. 59) Rate 1% lift charge | Sqm | 1336.23 | 1336.23 | 48.06 | False | None | None | False | None | False | 64219.2138 | 0 |
3099941 | 106626 | None | code81 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD DSR 2023-2024 ITEM NO. 8.2.1 P.NO. 41) | Sqm | 312.84 | 312.84 | 48.06 | False | None | None | False | None | False | 15035.0904 | 0 |
3099942 | 106626 | None | code82 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD DSR 2023-2024 ITEM NO. 8.10 P.NO. 43) Internal | Sqm | 223.76 | 223.76 | 476.22 | False | None | None | False | None | False | 106558.9872 | 0 |
3099943 | 106626 | None | code83 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD DSR 2023-2024 ITEM NO. 8.10 P.NO. 43) external | Sqm | 223.76 | 223.76 | 45.9 | False | None | None | False | None | False | 10270.584 | 0 |
3099944 | 106626 | None | code84 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(PWD DSR 2023-2024 ITEM NO. 8.5.2 P.NO. 42) | Sqm | 370.11 | 370.11 | 839.77 | False | None | None | False | None | False | 310807.2747 | 0 |
3099945 | 106626 | None | code85 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge..(2023-2024 ITEM NO. 8.51 P.NO. 50) | Sqm | 106.05 | 106.05 | 1316.0 | False | None | None | False | None | False | 139561.8 | 0 |
3099946 | 106626 | None | code86 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge (2023-2024 ITEM NO. 8.39 P.NO. 48) | Sqm | 134.68 | 134.68 | 1316.0 | False | None | None | False | None | False | 177238.88 | 0 |
3099947 | 106626 | None | code87 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. (PWD DSR 2023-2024 It. No. 8.8, P. No.42) | Sqm | 393.44 | 393.44 | 654.5 | False | None | None | False | None | False | 257506.48 | 0 |
3099948 | 106626 | None | code88 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(PWD DSR 2023-2024 It. No. 8.30, P. No.46) | Sqm | 184.52 | 184.52 | 700.4 | False | None | None | False | None | False | 129237.808 | 0 |
3099949 | 106626 | None | code89 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. (PWD DSR 2023-2024 It. No. 12.12, P. No.99) | Cum | 131716.22 | 131716.22 | 0.24 | False | None | None | False | None | False | 31611.8928 | 0 |
3099950 | 106626 | None | code90 | Clamps - MS (SL.NO 541) | Nos | 58.8 | 58.8 | 24.0 | False | None | None | False | None | False | 1411.2 | 0 |
3099951 | 106626 | None | code91 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.30 mm thick both side commercial (PWD DSR 2023-2024 It. No. 12.57.3, P. No.104) | Sqm | 3186.8 | 3186.8 | 10.71 | False | None | None | False | None | False | 34130.628 | 0 |
3099952 | 106626 | None | code92 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.(PWD DSR 2023-2024 It. No. 12.60, P. No.105) | Nos | 1115.64 | 1115.64 | 4.0 | False | None | None | False | None | False | 4462.56 | 0 |
3099953 | 106626 | None | code93 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD DSR 2023-2024 It. No. 8.41, P. No.48) | Sqm | 177.1 | 177.1 | 10.71 | False | None | None | False | None | False | 1896.741 | 0 |
3099954 | 106626 | None | code94 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 100mm (PWD DSR 2023-2024 It. No. 12.93.1, P. No.111) | Mtr | 744.47 | 744.47 | 26.45 | False | None | None | False | None | False | 19691.2315 | 0 |
3099955 | 106626 | None | code95 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum (PWD DSR 2023-2024 It. No. 12.94.1, P. No.112) 30 mm thickness | Sqm | 3695.84 | 3695.84 | 9.13 | False | None | None | False | None | False | 33743.0192 | 0 |
3099956 | 106626 | None | code96 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (PWD DSR 2023-2024 It. No. 12.90, P. No.110) | Sqm | 7141.4 | 7141.4 | 76.41 | False | None | None | False | None | False | 545674.374 | 0 |
3099957 | 106626 | None | code97 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(PWD DSR 2023-2024 It. No. 11.28, P. No.85) | Kgs | 599.18 | 599.18 | 195.0 | False | None | None | False | None | False | 116840.1 | 0 |
3099958 | 106626 | None | code98 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat withapproved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. (PWD DSR 2023-2024 It. No. 11.34B, P. No.86) | Kgs | 194.07 | 194.07 | 1604.61 | False | None | None | False | None | False | 311406.6627 | 0 |
3099959 | 106626 | None | code99 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD DSR 2023-2024 It. No. 8.41, P. No.48) | Sqm | 177.1 | 177.1 | 191.02 | False | None | None | False | None | False | 33829.642 | 0 |
3099960 | 106626 | None | code100 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. (PWD DSR 2023-2024 It. No. 10.2, P. No.69) | Mtr | 347.84 | 347.84 | 46.8 | False | None | None | False | None | False | 16278.912 | 0 |
3099961 | 106626 | None | code101 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on Newterrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU aterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. (PWD DSR 2023-2024 It. No. 15.1., P. No. 148) | Sqm | 866.42 | 866.42 | 342.128 | False | None | None | False | None | False | 296426.54176 | 0 |
3099962 | 106626 | None | code102 | Concealed Conduit System : Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary PWD Ele. SR 2023-24, Pg. No. 2, It No. 1.2.1 19/20 mm dia 2 mm thick | Rmtr | 66.0 | 66.0 | 500.0 | False | None | None | False | None | False | 33000.0 | 0 |
3099963 | 106626 | None | code103 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.PWD Ele. SR 2023-24, Pg. No. 2, It No. 1.3.1 19/20 mm dia 2 mm thick | Rmtr | 68.0 | 68.0 | 500.0 | False | None | None | False | None | False | 34000.0 | 0 |
3099964 | 106626 | None | code104 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:confirming to latest amendments.PWD Ele. SR 2023-24, Pg. No. 6, It No. 2.3.3 2.5 Sqmm | Mtr | 42.0 | 42.0 | 1500.0 | False | None | None | False | None | False | 63000.0 | 0 |
3099965 | 106626 | None | code105 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.PWD Ele. SR 2023-24, Pg. No. 6, It No. 2.3.4
4 Sqmm | Mtr | 63.0 | 63.0 | 1000.0 | False | None | None | False | None | False | 63000.0 | 0 |
3099966 | 106626 | None | code106 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall PWD Ele. SR 2023-24, Pg. No. 9, It No. 3.4.3 4-5 way | Nos | 177.0 | 177.0 | 10.0 | False | None | None | False | None | False | 1770.0 | 0 |
3099967 | 106626 | None | code107 | 8 way | Nos | 261.0 | 261.0 | 30.0 | False | None | None | False | None | False | 7830.0 | 0 |
3099968 | 106626 | None | code108 | 10-12 way | Nos | 319.0 | 319.0 | 10.0 | False | None | None | False | None | False | 3190.0 | 0 |
3099969 | 106626 | None | code109 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.PWD Ele. SR 2023-24, Pg. No. 9, It No. 3.5.3 4 Module | Nos | 175.0 | 175.0 | 10.0 | False | None | None | False | None | False | 1750.0 | 0 |
3099970 | 106626 | None | code110 | 8 Module | Nos | 284.0 | 284.0 | 30.0 | False | None | None | False | None | False | 8520.0 | 0 |
3099971 | 106626 | None | code111 | 12Module | Nos | 344.0 | 344.0 | 10.0 | False | None | None | False | None | False | 3440.0 | 0 |
3099972 | 106626 | None | code112 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.PWD Ele. SR 2023-24, Pg. No. 10, It No. 3.6.1 (6A One Way Switch) | Nos | 102.0 | 102.0 | 100.0 | False | None | None | False | None | False | 10200.0 | 0 |
3099973 | 106626 | None | code113 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. PWD Ele. SR 2023-24, Pg. No. 10, It No. 3.6.3 (6A Three Way socket) | Nos | 171.0 | 171.0 | 25.0 | False | None | None | False | None | False | 4275.0 | 0 |
3099974 | 106626 | None | code114 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.PWD Ele. SR 2023-24, Pg. No. 10, It No. 3.6.4 (Stepped Regulator) | Nos | 357.0 | 357.0 | 35.0 | False | None | None | False | None | False | 12495.0 | 0 |
3099975 | 106626 | None | code115 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.PWD Ele. SR 2023-24, Pg. No. 10, It No. 3.6.10 (6/16A Universal Socket) | Nos | 236.0 | 236.0 | 5.0 | False | None | None | False | None | False | 1180.0 | 0 |
3099976 | 106626 | None | code116 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.PWD Ele. SR 2023-24, Pg. No. 27, It No. 5.18.1 (6-32 A SP) | Nos | 415.0 | 415.0 | 20.0 | False | None | None | False | None | False | 8300.0 | 0 |
3099977 | 106626 | None | code117 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.PWD Ele. SR 2023-24, Pg. No. 28, It No. 5.19.2 (6 Way SP & N) | Nos | 1186.0 | 1186.0 | 5.0 | False | None | None | False | None | False | 5930.0 | 0 |
3099978 | 106626 | None | code118 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat.with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.PWD Ele. SR 2023-24, Pg. No. 30, It No. 5.41.2 (50 x 50 x 6 mm) | Nos | 395.0 | 395.0 | 2.0 | False | None | None | False | None | False | 790.0 | 0 |
3099979 | 106626 | None | code119 | Fabricating supplying and mounting MS box made out.SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.PWD Ele. SR 2023-24, Pg. No. 30, It No. 5.42.2 | Sq CM | 0.43 | 0.43 | 3000.0 | False | None | None | False | None | False | 1290.0 | 0 |
3099980 | 106626 | None | code120 | Earthing : Supplying fixing wiring earth electrod for grounding conduits IC cutouts and other equipments on the meter board using 40mm dia 2.90 thick GI pipe 2.5mtrs long burried in pit. Around the pipe to the complete depth the pipe shall have 16 nos of through holes of 12 mm dia PWD Ele. SR 2023-24, Pg. No. 54, It No. 12.56 (Earthing) | Nos | 3510.0 | 3510.0 | 1.0 | False | None | None | False | None | False | 3510.0 | 0 |
3099981 | 106626 | None | code121 | Digging of trench of 0.6m deep X0.5mtr wide refilling the trench to the required ground level and consolidating etc., complete PWD Ele. SR 2023-24, Pg. No. 41, It No. 6.62 In (HARD Soil) | Mtr | 102.0 | 102.0 | 50.0 | False | None | None | False | None | False | 5100.0 | 0 |
3099982 | 106626 | None | code122 | Supplying of 1.1 Kv LT UG cable XLPE or heat resistance PVC Insulated PVC Extruded inner sheath armoured UG LT csble as per IS-1554( part-1) PWD Ele. SR 2023-24, Pg. No. 40, It No. 32.05 (4 core 16Sqmm) | Mtr | 141.84 | 141.84 | 50.0 | False | None | None | False | None | False | 7092.0 | 0 |
3099983 | 106626 | None | code123 | Labour Charges for laying 1.1 Kv class UG cable when supplied agency in existing trench GI pipe / Stoneware pipe/on wall/ on pole as required PWD Ele. SR 2023-24, Pg. No. 41, It No. 6.5.1 (Existing Trench / duct) | Mtr | 11.88 | 11.88 | 50.0 | False | None | None | False | None | False | 594.0 | 0 |
3099984 | 106626 | None | code124 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.48" Sweep (1200 mm) Regular model PWD Ele. SR 2023-24, Pg. No. 46, It No. 6.3 | Nos | 2984.0 | 2984.0 | 32.0 | False | None | None | False | None | False | 95488.0 | 0 |
3099985 | 106626 | None | code125 | Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clA and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.PWD Ele. SR 2023-24, Pg. No. 80, It No. 13.10 | Nos | 171.0 | 171.0 | 32.0 | False | None | None | False | None | False | 5472.0 | 0 |
3099986 | 106626 | None | code126 | Supplying of .feet -PVC Batten with integrated LED tube .with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition PWD Ele. SR 2023-24, Pg. No. 64, It No. 11.3.2 | Nos | 690.0 | 690.0 | 50.0 | False | None | None | False | None | False | 34500.0 | 0 |
3099987 | 106626 | None | code127 | Supplying & fixing retrofit type-P L- LEDLamp.W LED linea rsource with CCT6500 degree K, CRI 70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS10322/IEC60598, LM79 &LM80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should % of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM79. The operating input voltage should be between 130to 275V. Tested by NABL / CPR Iaccred ited laboratory with 2years Warranty against any manufacturing defect working under standard electrical condition.PWD Ele. SR 2023-24, Pg. No. 43, It No. 11.2.2 (18-20wa) | Nos | 702.0 | 702.0 | 20.0 | False | None | None | False | None | False | 14040.0 | 0 |
3099988 | 106626 | None | code128 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA.On wall/ ceiling / Rafter / Girders PWD Ele. SR 2023-24, Pg. No. 64, It No. 13.19 (On wall/ ceiling / Rafter / Girders) | Nos | 490.0 | 490.0 | 100.0 | False | None | None | False | None | False | 49000.0 | 0 |
3099989 | 106626 | None | code129 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ....... W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.LED Floodlight 70W PWD Ele. SR 2023-24, Pg. No. 46, It No. 11.9.1 (70W) | Nos | 6768.0 | 6768.0 | 2.0 | False | None | None | False | None | False | 13536.0 | 0 |
3099990 | 106626 | None | code130 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid ( Page No- 131 , Item No- 14.2.1 ) | Nos | 5079.9 | 5079.9 | 7.0 | False | None | None | False | None | False | 35559.3 | 0 |
3099991 | 106626 | None | code131 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps ( Page No- 132 , Item No- 14.7.3 ) | Nos | 3009.3 | 3009.3 | 7.0 | False | None | None | False | None | False | 21065.1 | 0 |
3099992 | 106626 | None | code132 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 32mm ( Page No- 136 , Item No- 14.28.2 ) | Nos | 96.6 | 96.6 | 7.0 | False | None | None | False | None | False | 676.2 | 0 |
3099993 | 106626 | None | code133 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. ( Page No- 136 , Item No- 14.31 ) | Nos | 1281.0 | 1281.0 | 7.0 | False | None | None | False | None | False | 8967.0 | 0 |
3099994 | 106626 | None | code134 | Providing and fixing brass bib cock 20mm nominal bore (Page No- 116, Item No- 13.2.2) | Nos | 320.25 | 320.25 | 20.0 | False | None | None | False | None | False | 6405.0 | 0 |
3099995 | 106626 | None | code135 | Providing and fixing unplasticised PVC connection pipe with brass union 20mm nominal bore 450 mm length of PVC connection including cost of all materials, labour and HOM of equipments with all leads complete as per specifications.( Page No-118 Item No-13.8.2.2) | Nos | 115.5 | 115.5 | 15.0 | False | None | None | False | None | False | 1732.5 | 0 |
3099996 | 106626 | None | code136 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of pproved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and
effective height of 88 mm, weighing not less than 190 g. ( Page No-137 Item No-14.40.2) | Nos | 520.8 | 520.8 | 7.0 | False | None | None | False | None | False | 3645.6 | 0 |
3099997 | 106626 | None | code137 | Providing and fixing in position Jaquar / Hindware / Parry ware or equivalent Health faucet complete set of approved quality 20mm nominal bore including cost of all materials( Angle stop cock with flanges , flexible tube 1mtr length , hand operated spray unit ) labour and HOM of equipments with all lead, lift, loading, unloading & HOM charges etc., complete as per specifications. and directions of the Engineer-in-charge of work. ( MR) | Nos | 1522.5 | 1522.5 | 7.0 | False | None | None | False | None | False | 10657.5 | 0 |
3099998 | 106626 | None | code138 | Providing and fixing in position brass stop cock of approved quality 15/20mm nominal bore including cost of all materials labour and HOM of equipments with all leads complete as per specifications ( Page No -117 Item No- 13.3.2 ) | Nos | 320.25 | 320.25 | 35.0 | False | None | None | False | None | False | 11208.75 | 0 |
3099999 | 106626 | None | code139 | Providing and fixing PTMT pillar cock of approved quality and colour.15 mm nominal bore, 125 mm long foam flow, weighing not less than 120 gms ( Page No -120 Item No- 13.20.2 ) | Nos | 329.7 | 329.7 | 7.0 | False | None | None | False | None | False | 2307.9 | 0 |
3100000 | 106626 | None | code140 | Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete) ( Page No- 127 , Item No- 13.59) | Nos | 231.0 | 231.0 | 20.0 | False | None | None | False | None | False | 4620.0 | 0 |
3100001 | 106626 | None | code141 | Providing and fixing PTMT grating of approved quality and colour. 100 mm nominal dia( Page No-120, Item No - 13.2.1.1) | Nos | 43.05 | 43.05 | 20.0 | False | None | None | False | None | False | 861.0 | 0 |
3100002 | 106626 | None | code142 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber 100mm x 100mm size P type with Non Modular common burnt clay bricks of designation 3.5& water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of
cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: ( Page No- 123 , Item No- 13.38) | Nos | 2658.6 | 2658.6 | 4.0 | False | None | None | False | None | False | 10634.4 | 0 |
3100003 | 106626 | None | code143 | Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.( Page No-120, Item No - 14.33) | Nos | 951.3 | 951.3 | 7.0 | False | None | None | False | None | False | 6659.1 | 0 |
3100004 | 106626 | None | code144 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC
plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints com plete as per direction of Engineer in Charge.
Internal work - Exposed on wall( Page No- 122, Item No- 13.31) 20 mm dia NB | Mtr | 191.1 | 191.1 | 100.0 | False | None | None | False | None | False | 19110.0 | 0 |
3100005 | 106626 | None | code145 | 25 mm dia NB | Mtr | 333.9 | 333.9 | 100.0 | False | None | None | False | None | False | 33390.0 | 0 |
3100006 | 106626 | None | code146 | 32 mm dia NB | Mtr | 420.0 | 420.0 | 100.0 | False | None | None | False | None | False | 42000.0 | 0 |
3100007 | 106626 | None | code147 | 40 mm nominal dia Pipes | Mtr | 562.8 | 562.8 | 50.0 | False | None | None | False | None | False | 28140.0 | 0 |
3100008 | 106626 | None | code148 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good thewalls etc.( Page No-122, Item No- 13.32) 20 mm dia NB | Mtr | 397.95 | 397.95 | 50.0 | False | None | None | False | None | False | 19897.5 | 0 |
3100009 | 106626 | None | code149 | 25 mm dia NB | Mtr | 500.85 | 500.85 | 50.0 | False | None | None | False | None | False | 25042.5 | 0 |
3100010 | 106626 | None | code150 | 32 mm dia NB | Mtr | 584.85 | 584.85 | 50.0 | False | None | None | False | None | False | 29242.5 | 0 |
3100011 | 106626 | None | code151 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : :pg-117 itm 13.4 ( - 25 mm dia nominal bore) | Each | 576.45 | 576.45 | 5.0 | False | None | None | False | None | False | 2882.25 | 0 |
3100012 | 106626 | None | code152 | 32 mm dia nominal bore | Each | 627.9 | 627.9 | 5.0 | False | None | None | False | None | False | 3139.5 | 0 |
3100013 | 106626 | None | code153 | 40 mm dia nominal bore | Each | 737.1 | 737.1 | 5.0 | False | None | None | False | None | False | 3685.5 | 0 |
3100014 | 106626 | None | code154 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (For 1000 litre capacity) Specification No. KBS 13.22( Page No- 123 Item No- 13.34 | Ltr | 9.45 | 9.45 | 3000.0 | False | None | None | False | None | False | 28350.0 | 0 |
3100015 | 106626 | None | code155 | Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with lectrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0 ( Page No- 95,Item No-9.1) 160mm dia | Mtr | 1006.95 | 1006.95 | 70.0 | False | None | None | False | None | False | 70486.5 | 0 |
3100016 | 106626 | None | code156 | 110mm dia | Mtr | 492.45 | 492.45 | 30.0 | False | None | None | False | None | False | 14773.5 | 0 |
3100017 | 106626 | None | code157 | 75mm dia | Mtr | 257.25 | 257.25 | 30.0 | False | None | None | False | None | False | 7717.5 | 0 |
3100018 | 106626 | None | code158 | Providing and fixing on wall face unplasticised Rigid PVC rain waterpipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i)Single socketed pipes 100 mm diameter( Page No-125, Item No- 13.48) | Mtr | 305.55 | 305.55 | 100.0 | False | None | None | False | None | False | 30555.0 | 0 |
3100019 | 106626 | None | code159 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifi cations, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.. (PWD DSR 2023-2024 It. No. 1.6, P. No. 6 | Mtr | 508.2 | 508.2 | 40.0 | False | None | None | False | None | False | 20328.0 | 0 |
3100020 | 106626 | None | code160 | KSRB 12-8.1: Constructing brick masonry Inspection chamber 600x600mm and 450mm depth (clear inside dimension) for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover with frame (light duty) 600x600mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23kg and weight of frame 15kg) R.C.C top slab with cement concrete M 15 with 20mm and downsize granite metal, foundation concrete M 5 with 40mm and downsize granite metal inside plastering 12mm thick with cement mortar 1:3, finish smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials, labour charges, curing complete as per specifications. specifications No. KBS( Page No - 75 Item No- 11.50.2) | Nos | 8914.5 | 8914.5 | 16.0 | False | None | None | False | None | False | 142632.0 | 0 |