1710516467000 | 0 | None | None | Other Works | Construction Of Badminton Court at Ex-Servicemen Colony in Ward No 31 in Ballari City | 2965770.42 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3100888 | 106650 | None | code01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. Common SR 2023-24, Volume-I, Item No. 1.14.1 | Cum | 107.1 | 107.1 | 47.3607 | False | None | None | False | None | False | 5072.33097 | 0 | 3100889 | 106650 | None | code02 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates. Common SR 2023-24, Volume-I, Item No. 2.1.2 | Cum | 5947.2 | 5947.2 | 18.0386 | False | None | None | False | None | False | 107279.16192 | 0 | 3100890 | 106650 | None | code03 | Centering for Footing. Common SR 2023-24,Volume-I,Appendix,Item No. 1a, P.No.111, Rate: 8 % of Finished Item of concrete | Cum | 537.94 | 537.94 | 11.34 | False | None | None | False | None | False | 6100.2396 | 0 | 3100891 | 106650 | None | code04 | Centering for Columns. Common SR 2023-24,Volume-I, Appendix, Item No. 9, P.No.111, Rate: 70 % of Finished Item of concrete | Cum | 4706.94 | 4706.94 | 10.4 | False | None | None | False | None | False | 48952.176 | 0 | 3100892 | 106650 | None | code05 | Centering for Beams, Common SR 2023-24,Volume-I, Appendix, Item No. 2, P.No.111, Rate: 50 % of Finished Item of concrete | Cum | 3362.1 | 3362.1 | 20.6089 | False | None | None | False | None | False | 69289.18269 | 0 | 3100893 | 106650 | None | code06 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. Common SR 2023-24,Volume-I,Item No. 1.9 | Cum | 279.3 | 279.3 | 19.6 | False | None | None | False | None | False | 5474.28 | 0 | 3100894 | 106650 | None | code07 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paidseparately) Common SR 2023-24,Volume-I,Item No.2.4.1 page no 16 | Cum | 6724.2 | 6724.2 | 17.8044 | False | None | None | False | None | False | 119720.34648 | 0 | 3100895 | 106650 | None | code08 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) Common SR 2023-24,Volume-II ,Item No.5.4 P NO 9 | Cum | 6708.45 | 6708.45 | 8.1351 | False | None | None | False | None | False | 54573.911595 | 0 | 3100896 | 106650 | None | code09 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Common SR 2023-24,Volume-I,Item No.2.5.1 P NO 16 | Cum | 6961.5 | 6961.5 | 22.6168 | False | None | None | False | None | False | 157446.8532 | 0 | 3100897 | 106650 | None | code10 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Common SR 2023-24,Volume-I,Item No.2.11 P NO 18, Qty as per above item
no.8 | Tonne | 93929.85 | 93929.85 | 3.6379 | False | None | None | False | None | False | 341707.401315 | 0 | 3100898 | 106650 | None | code11 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Common SR 2023-24,Volume-II,Item No. 6.2 P NO 13 | Cum | 8376.9 | 8376.9 | 53.5564 | False | None | None | False | None | False | 448636.60716 | 0 | 3100899 | 106650 | None | code12 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer- in-charge. Common SR 2023-24,Volume-2,Item No.8.2.2 P NO 41 | Sqm | 292.95 | 292.95 | 465.7076 | False | None | None | False | None | False | 136429.04142 | 0 | 3100900 | 106650 | None | code13 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 100mm. Common SR 2023-24,Volume-2,Item No.12.93.2 | m | 802.2 | 802.2 | 28.6 | False | None | None | False | None | False | 22942.92 | 0 | 3100901 | 106650 | None | code14 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 30 mm thickness. Common SR 2023-24,Volume-2,Item No.12.94.1 | Sqm | 3659.25 | 3659.25 | 9.45 | False | None | None | False | None | False | 34579.9125 | 0 | 3100902 | 106650 | None | code15 | Providing and fixing Stainless Steel Fixtures conforming to 304graded steel as per direction of engineer in charge.PWD CSR 2023-24, Vol-II, P. No. 218, I. No. 22.15 , SS Handles 200mm I NO. 22.15.1 | No | 472.5 | 472.5 | 8.0 | False | None | None | False | None | False | 3780.0 | 0 | 3100903 | 106650 | None | code16 | Providing and fixing Stainless Steel Fixtures conforming to 304graded steel as per direction of engineer in charge.PWD CSR 2023-24, Vol-II, P. No. 218, I. No. 22.15 , SS Aldrop 16mm dia, 200mm I NO . 22.15.3 | No | 315.0 | 315.0 | 4.0 | False | None | None | False | None | False | 1260.0 | 0 | 3100904 | 106650 | None | code17 | Providing and fixing Stainless Steel Fixtures conforming to 304graded steel as per direction of engineer in charge.PWD CSR 2023-24, Vol-II, P. No. 218, I. No. 22.15 , SS Tower Bolts 200x10mm I NO. 22.15.6 | No | 157.5 | 157.5 | 4.0 | False | None | None | False | None | False | 630.0 | 0 | 3100905 | 106650 | None | code18 | Providing and fixing Stainless Steel Fixtures conforming to 304graded steel as per direction of engineer in charge.PWD CSR 2023-24, Vol-II, P. No. 218, I. No. 22.15, SS hinges 100 mm I NO. 22.15.9 | No | 73.5 | 73.5 | 12.0 | False | None | None | False | None | False | 882.0 | 0 | 3100906 | 106650 | None | code19 | Providing and fixing unplasticised PVC connection pipe with brass unions :45 cm length, 20mm NB PWD CSR 2023-24, Vol-II, P. No. 118, I. No. 13.8.2.2 | No | 115.5 | 115.5 | 2.0 | False | None | None | False | None | False | 231.0 | 0 | 3100907 | 106650 | None | code20 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. PWD CSR 2023-24, Vol-II, P. No. 122, I. No. 13.32.3 25 mm nominal dia pipes | m | 500.85 | 500.85 | 15.0 | False | None | None | False | None | False | 7512.75 | 0 | 3100908 | 106650 | None | code21 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work PWD CSR 2023-24, Vol-II, P. No. 122, I. No. 13.33.4 32 mm nominal dia | m | 390.6 | 390.6 | 5.0 | False | None | None | False | None | False | 1953.0 | 0 | 3100909 | 106650 | None | code22 | Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete PWD CSR 2023-24, Vol-II, P. No. 127, I. No. 13.59 | No | 231.0 | 231.0 | 4.0 | False | None | None | False | None | False | 924.0 | 0 | 3100910 | 106650 | None | code23 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid PWD CSR 2023-24, Vol-II, P. No. 131, I. No. 14.3.1 | Each | 6275.85 | 6275.85 | 1.0 | False | None | None | False | None | False | 6275.85 | 0 | 3100911 | 106650 | None | code24 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps PWD CSR 2023-24, Vol-II, P. No. 132, I. No. 14.7.1 | Each | 3236.1 | 3236.1 | 1.0 | False | None | None | False | None | False | 3236.1 | 0 | 3100912 | 106650 | None | code25 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 1500x450 mm (PWD CSR 2023-24, Vol-II, P. No. 136, I. No. 14.32.4, | Each | 1812.3 | 1812.3 | 1.0 | False | None | None | False | None | False | 1812.3 | 0 | 3100913 | 106650 | None | code26 | Providing and fixing Bib cock with wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete Economy Class PWD CSR 2023-24, Vol-II, P. No. 139, I. No. 14.55 a | Each | 1172.85 | 1172.85 | 2.0 | False | None | None | False | None | False | 2345.7 | 0 | 3100914 | 106650 | None | code27 | Providing and fixing brass curtain rods of wall thickness 1.25 mm withtwo brass brackets fixed with brass screws and wooden plugs etc.wherever necessarY COMPLETELY (PWD CSR 2023-24, Vol-II, P. No.199, I NO 20.22.2 ) 25 mm diameter. | m | 660.45 | 660.45 | 2.0 | False | None | None | False | None | False | 1320.9 | 0 | 3100915 | 106650 | None | code28 | Providing & fixing 100% Polyester Curtains with specification ofregular wash as per direction of Engineer in charge (PWD CSR 2023-24, Vol-II, P. No.199, I NO 22.24 ) | Sqm | 1260.0 | 1260.0 | 4.2 | False | None | None | False | None | False | 5292.0 | 0 | 3100916 | 106650 | None | code29 | Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013with latest amendments ended with integral sockets with ISI mark andconveying to worksite, rolling and lowering into trenches, laying true toline and level and perfect linking at joints, testing and commissioning,including loading and unloading at both destinations and cuts of pipeswherever necessary including jointing of UPVC pipes (with cost ofelastomeric sealing rings) and specials (excluding cost of specials) withjointing of approved type, with all labour, lead & lifts, including encasingthe pipes alround to a depth of not less than 15 cms. with soft gravelor selected earth available from the excavation etc. complete and givingnecessary hydraulic test to the required pressure as per ISS (contractorwill make his own arrangements for procuring water for testing) etc.complete for: (p.no.120. it.no10.2.10 PAGE NO 114 Pipes of SN 8, 160mm dia.) 2023-24 WATER SUPPLY AND UGD WORKS COMMON SCHEDULE OF RATES VOLUME-V | m | 731.85 | 731.85 | 1.0 | False | None | None | False | None | False | 731.85 | 0 | 3100917 | 106650 | None | code30 | Constructing brick masonry chamber of internal dimension 600x600mmand depth of 600mm (inner dimensions) with modular bricks of CD 75in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixingCI cover & frame etc. excluding the cost of CI frame and cover.. (PWD CSR 2023-24, Vol-5 , P. No. 191, I. No. 16.9) | Each | 5726.7 | 5726.7 | 1.0 | False | None | None | False | None | False | 5726.7 | 0 | 3100918 | 106650 | None | code31 | Providing and laying 100mm thick pre-cast cover slabs over Road sidedrains / utility ducts / Rain water harvesting pit of width not exceeding1000 mm using M20 concrete reinforced with TMT bars Fe 550 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Includingproviding holes in the Cover slabs wherever necessary for easy drainageof surface water including of labour, materials, scaffolding, usage ofmachinery, curing, lead and lift charges etc, Complete. (PWD CSR 2023-24, Vol-2 , P. No. 177, I. No. 17.14 ) | Sqm | 1228.5 | 1228.5 | 0.49 | False | None | None | False | None | False | 601.965 | 0 | 3100919 | 106650 | None | code32 | Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments (PWD CSR 2023-24, Vol5 , P. No. 117 , I. No. , 10.9.8 . 110 mm dia PVC Elbows | Each | 317.1 | 317.1 | 4.0 | False | None | None | False | None | False | 1268.4 | 0 | 3100920 | 106650 | None | code33 | Supply and delivery at site special moulded variety PVC tee as per IS7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments (PWD CSR 2023-24, Vol5 , P. No. 117 , I. No. , 10.10.8. 110 mm dia PVC Tee | Each | 263.55 | 263.55 | 4.0 | False | None | None | False | None | False | 1054.2 | 0 | 3100921 | 106650 | None | code34 | Supply and delivery at site special moulded variety PVC reducer as perIS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark withits latest amendments10.13.8 Each 261(PWD CSR 2023-24, Vol5 , P. No. 117 , I. No. , 10.13.8 Each, 110 mm dia PVC REDUCER | Each | 274.05 | 274.05 | 4.0 | False | None | None | False | None | False | 1096.2 | 0 | 3100922 | 106650 | None | code35 | ELECTRICAL WORKS : Concealed PVC Conduit System Supplying heavy gauge PVC Conduit Pipe 19/20 mm dia 2 mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19/20 mm dia 2mm thick (P.no.2.it.no.1.2.1) (PWD CSR for PART -III Electrical Works for the Year 2023-24) | m | 69.3 | 69.3 | 80.0 | False | None | None | False | None | False | 5544.0 | 0 | 3100923 | 106650 | None | code36 | PVC/metal conduit Deep Junction Box Supplying and fixing PVC/metal conduit Deep junction box 19/20mm Deep Junction Box (P.no.2.it.no.1.5.1 ) (PWD CSR for PART -III Electrical Works for the Year 2023-24) | Each | 51.45 | 51.45 | 18.0 | False | None | None | False | None | False | 926.1 | 0 | 3100924 | 106650 | None | code37 | Flush Mounting Wooden Box Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete. 8" x 6" x 3" (203 x 152 x 76 mm) (P.no.3.it.no.1.6.4) (PWD CSR for PART -III Electrical Works for the Year 2023-24) | Each | 90.3 | 90.3 | 6.0 | False | None | None | False | None | False | 541.8 | 0 | 3100925 | 106650 | None | code38 | Flush Mounting Wooden Box Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete. 4" x 4" x 3" ( 101 x 101 x 76 mm) (P.no.3.it.no.1.6.6) (PWD CSR for PART -III Electrical Works for the Year 2023-24) | Each | 77.7 | 77.7 | 4.0 | False | None | None | False | None | False | 310.8 | 0 | 3100926 | 106650 | None | code39 | Wiring for Lightings/Power Circuit Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.1.5 Sqmm (P.no.5.it.no.2.3.2) (PWD CSR for PART -III Electrical Works for the Year 2023-24) | m | 27.3 | 27.3 | 200.0 | False | None | None | False | None | False | 5460.0 | 0 | 3100927 | 106650 | None | code40 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.5 Sqmm (P.no.5.it.no.2.3.3) (PWD CSR for PART -III Electrical Works for the Year 2023-24) | m | 44.1 | 44.1 | 120.0 | False | None | None | False | None | False | 5292.0 | 0 | 3100928 | 106650 | None | code41 | Modular Switches/Sockets/Regulators etc Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps one way SWITCH (P.no.9.it.no.3.6.1) (PWD CSR for PART -III Electrical Works for the Year 2023-24) | Each | 107.1 | 107.1 | 20.0 | False | None | None | False | None | False | 2142.0 | 0 | 3100929 | 106650 | None | code42 | Modular Switches/Sockets/Regulators etc Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps two way SWITCH . (P.no.9.it.no.3.6.2) (PWD CSR for PART -III Electrical Works for the Year 2023-24) | Each | 174.3 | 174.3 | 20.0 | False | None | None | False | None | False | 3486.0 | 0 | 3100930 | 106650 | None | code43 | Modular Switches/Sockets/Regulators etc Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 16Amps one way switch (P.no.9.it.no.3.6.7) .(PWD CSR for Electrical Works for the Year 2023-24) | Each | 189.0 | 189.0 | 20.0 | False | None | None | False | None | False | 3780.0 | 0 | 3100931 | 106650 | None | code44 | Porcelain Fuse Channel Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 32Amps (P.no.10.it.no.5.7.2) (PWD CSR for PART -III Electrical Works for the Year 2023-24) | Each | 253.05 | 253.05 | 6.0 | False | None | None | False | None | False | 1518.3 | 0 | 3100932 | 106650 | None | code45 | Miniature Circuit Breakers Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898, (p.no.17.it.no.5.18.1 ) (PWD CSR for PART -III Electrical Works for the Year 2023-24) 6-32 Amps SP | Each | 435.75 | 435.75 | 6.0 | False | None | None | False | None | False | 2614.5 | 0 | 3100933 | 106650 | None | code46 | Miniature Circuit Breakers Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898, (p.no.17.it.no. 5.18.4 ) (PWD CSR for PART -III Electrical Works for the Year 2023-24) 6-32 A DP | Each | 775.95 | 775.95 | 6.0 | False | None | None | False | None | False | 4655.7 | 0 | 3100934 | 106650 | None | code47 | MCB Distribution Boards Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.I - Single Door 8 Way SP & N (p.no.18.it.no.5.19.3)(PWD CSR for PART -III Electrical Works for the Year 2023-24) | Each | 1566.6 | 1566.6 | 4.0 | False | None | None | False | None | False | 6266.4 | 0 | 3100935 | 106650 | None | code48 | PVC Batten with LED Tubes Supplying of 1X4 feet - PVC Batten with integrated LED tube 20/22 W with high quality diff user with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor Greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fighting 14- 20/22 w (p.no.43.it.no.11.3.2) (PWD CSR for PART -III Electrical Works for the Year 2023-24) | Each | 724.5 | 724.5 | 4.0 | False | None | None | False | None | False | 2898.0 | 0 | 3100936 | 106650 | None | code49 | LED Down Lights Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor Greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W (p.no.43.it.no.11.5.3) (PWD CSR for PART -III Electrical Works for the Year 2023-24), LED square or round down light 15-18W for false ceiling | Each | 1390.2 | 1390.2 | 20.0 | False | None | None | False | None | False | 27804.0 | 0 | 3100937 | 106650 | None | code50 | Lamp Holder Supplying & Fixing of 70-150 Watts lamp holder 2 Pin (p.no.52.it.no.12.46) (PWD CSR for PART -III Electrical Works for the Year 2023-24) | No | 66.15 | 66.15 | 10.0 | False | None | None | False | None | False | 661.5 | 0 | 3100938 | 106650 | None | code51 | Supplyingexhaustfanof1440RPMof300mm(12")sizewithbracketbladescompleteforlightdutysuitabletooperateon230V50Hz, AC Supply. (PWD CSR for Electrical Works for the Year 2023-24 , P.no.30.it.no.6.1 | Each | 1566.6 | 1566.6 | 2.0 | False | None | None | False | None | False | 3133.2 | 0 | 3100939 | 106650 | None | code52 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of antiglare clear diffuser with Injection moulded polycarbonate/ clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT Greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire Greater than IK08. Power Factor Greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer
dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range
from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598,
LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 100W System
Power consumption. LED EfficiencyGreater than1301m/w, nominal CRI Greater than75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved /Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.. (PWD CSR for Electrical Works for the Year 2023-24, i no 11.9.2 LED Floodlight 100W page no 46 | Each | 9960.3 | 9960.3 | 1.0 | False | None | None | False | None | False | 9960.3 | 0 | 3100940 | 106650 | None | code53 | Supplying,fixing,wiring,earthelectrodeforgroundingconduits,I.C.cutoutsandotherequipment'sonthemeterboardusing40mmdia2.90mmthickGIpipe2.5mlongburiedinapit.Thepitshouldbefilledwithequalproportionofsaltandcharcoal150mmall-round the pipe completdepth.Theconnectionfromthepipetotheconduitetc.,istobeestablishedthroughGIwireofsizeasperlSIspecification7.3.3.ofIS732using12mmdiabolts,nuts,washersandchecknutsetc., the pipe shall have 16 through holes of 12 mm dia . (PWD CSR for Electrical Works for the Year 2023-24 P.no.54.it.no.12.56) | No. | 3685.5 | 3685.5 | 1.0 | False | None | None | False | None | False | 3685.5 | 0 | 3100941 | 106650 | None | code54 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Common SR 2023-24,Volume-2,Item No.8.30 | Sqm | 182.7 | 182.7 | 486.6656 | False | None | None | False | None | False | 88913.80512 | 0 | 3100942 | 106650 | None | code55 | Truss Less Roof (MR) | Sqm | 2250.0 | 2250.0 | 225.055 | False | None | None | False | None | False | 506373.75 | 0 | 3100943 | 106650 | None | code56 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. Common SR 2023-24,Volume-2,Item No.7.38 | Sqm | 596.4 | 596.4 | 364.573 | False | None | None | False | None | False | 217431.3372 | 0 | 3100944 | 106650 | None | code57 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in Charge. Common SR 2023-24,Volume-2,Item No.11.25.2 | Kgs | 142.8 | 142.8 | 1958.0 | False | None | None | False | None | False | 279602.4 | 0 | 3100945 | 106650 | None | code58 | Providing and fixing RCC name board of size 1.35x0.60x0.04
m fixed in reinforced cement concrete poles of size
0.10x0.10x2.60m in cement concrete M 20 proportion using
20mm and down size graded metal machine mixed with
10mm dia main steel bars and 8mm dia stirpes as shown in
drawing. The board shall be provided with 12mm thick cement
plaster in cement mortar 1:4 on both the sides. The poles shall
be embedded in the ground for a depth of 0.5 m with cement
concrete M 10 proportion. The board shall be fixed as per the
drawing and at the place indicated by the Engineer in charge
of the work. The cost includes excavation, cost of all materials,
cost of steel, painting, centering, transportation charges &
fixing charges. Common SR 2023-24,Volume-3,Item No.8.55 p no 79 | No | 6154.05 | 6154.05 | 1.0 | False | None | None | False | None | False | 6154.05 | 0 | 3100946 | 106650 | None | code59 | Wooden Flooring ( market rate ) | Sqm | 2055.0 | 2055.0 | 81.74 | False | None | None | False | None | False | 167975.7 | 0 | 3100947 | 106650 | None | code60 | Gescom Meter Deposit Charges | Each | 2500.0 | 2500.0 | 1.0 | False | None | None | False | None | False | 2500.0 | 0 |
|