createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1710507016001
version2
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeONE_COVER
evaluationTypeTextOne Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee750.00
emd70000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose01-04-2024 16:25:00
tenderQueryClose01-04-2024 16:20:00
technicalBidOpenNone
publishedDate15-03-2024 18:32:48
publishedByPostDMA_EE6_CC_MYS
publishedByUserKPE13419 - B NAGARAJ
bidValidityPeriod180
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonManjunath B
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9480382135
tenderSupplierListNone
tenderSchedule
createdTs1710507016032
version4
createdDateNone
modifiedDateNone
tenderNumberDMA/2023-24/BD/WORK_INDENT17718
titleConstruction of Public toilet at New DC Office Premises, Bannur road, mysore.
descriptionConstruction of Public toilet at New DC Office Premises, Bannur road, mysore.
categoryWORKS
categoryTextWorks
ecv2965888.72
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location2163
locationNameDMA City Corporation Mysuru
provisionalAmount3500000.0
groupOverheadTotalNone
fileNumberMCCEEWSUGD0415032024
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17105070160000NoneNoneBuildingsConstruction of Public toilet at New DC Office Premises, Bannur road, mysore.2965888.72
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3096904106488Nonecode01Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth.Cum313.95313.9555.16FalseNoneNoneFalseNoneFalse17317.4820
3096905106488Nonecode02Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 40 mm nominal size graded crushed coarse aggregatesCum6463.86463.815.27FalseNoneNoneFalseNoneFalse98702.2260
3096906106488Nonecode03Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Foundation in CM 1:6.Cum6692.76692.730.21FalseNoneNoneFalseNoneFalse202186.4670
3096907106488Nonecode04Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Basement in CM 1:6.Cum6770.46770.413.22FalseNoneNoneFalseNoneFalse89504.6880
3096908106488Nonecode05Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates.Cum7866.187866.1810.24FalseNoneNoneFalseNoneFalse80549.68320
3096909106488Nonecode06Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.356.73FalseNoneNoneFalseNoneFalse15844.6890
3096910106488Nonecode07Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1375.51375.5110.18FalseNoneNoneFalseNoneFalse151552.590
3096911106488Nonecode08Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1292.551292.55116.88FalseNoneNoneFalseNoneFalse151073.2440
3096912106488Nonecode09Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Cum10442.2510442.2522.25FalseNoneNoneFalseNoneFalse232340.06250
3096913106488Nonecode10Steel Fabrication-Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Tonne93929.8593929.852.67FalseNoneNoneFalseNoneFalse250792.69950
3096914106488Nonecode11Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge.Sqm4701.94701.96.3FalseNoneNoneFalseNoneFalse29621.970
3096915106488Nonecode12Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm339.15339.1593.83FalseNoneNoneFalseNoneFalse31822.44450
3096916106488Nonecode13Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:3 (1 cement: 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm384.3384.3333.5FalseNoneNoneFalseNoneFalse128164.050
3096917106488Nonecode14Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm404.25404.25250.21FalseNoneNoneFalseNoneFalse101147.39250
3096918106488Nonecode15Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 L per 50 kg of cement or as per direction of Engineer incharge.Sqm840.0840.026.46FalseNoneNoneFalseNoneFalse22226.40
3096919106488Nonecode16Providing and laying Cement concrete pavement with 1:2:4 for commercial & residential building floors, hardpaths, footpaths using 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size, including finishing complete as per Engineer incharge.Cum6999.36999.31.89FalseNoneNoneFalseNoneFalse13228.6770
3096920106488Nonecode17Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2 including pointing in white cement mixed with pigment of matching shade complete.Sqm1161.31161.385.71FalseNoneNoneFalseNoneFalse99535.0230
3096921106488Nonecode18Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.Sqm1461.61461.6303.56FalseNoneNoneFalseNoneFalse443683.2960
3096922106488Nonecode19Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-do- 40 mm thick both side Teak.Sqm5208.05208.021.0FalseNoneNoneFalseNoneFalse109368.00
3096923106488Nonecode20Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm X 57mm with Gi reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8+-0.2 Maximum possible size 1519mm x 1519mm. The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made).Sqm5659.55659.54.5FalseNoneNoneFalseNoneFalse25467.750
3096924106488Nonecode21Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.Kg176.4176.4359.1FalseNoneNoneFalseNoneFalse63345.240
3096925106488Nonecode22Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm27.327.3167.44FalseNoneNoneFalseNoneFalse4571.1120
3096926106488Nonecode23Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life).Sqm165.9165.9167.44FalseNoneNoneFalseNoneFalse27778.2960
3096927106488Nonecode24Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm186.9186.9195.94FalseNoneNoneFalseNoneFalse36621.1860
3096928106488Nonecode25Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm175.35175.3534.7FalseNoneNoneFalseNoneFalse6084.6450
3096929106488Nonecode26Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth.Sqm2928.452928.454.8FalseNoneNoneFalseNoneFalse14056.560
3096930106488Nonecode27Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi -rigid, inorganic, non-combustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 Part 5. The insulation layer shall have facing (factory bonded on surface no 1 of the fibre glass insulation layer), of black non-woven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 g/m2,made of randomly oriented glass fibres distributed in a binder by a wet-lay process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc completeSqm2035.952035.956.9FalseNoneNoneFalseNoneFalse14048.0550
3096931106488Nonecode28Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin- ChargeSqm188.49188.4981.2FalseNoneNoneFalseNoneFalse15305.3880
3096932106488Nonecode29Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests.Each5128.25128.26.0FalseNoneNoneFalseNoneFalse30769.20
3096933106488Nonecode30Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid.Each6275.856275.854.0FalseNoneNoneFalseNoneFalse25103.40
3096934106488Nonecode31Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever requiredEach4676.74676.74.0FalseNoneNoneFalseNoneFalse18706.80
3096935106488Nonecode32Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:.White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar tapsEach3236.13236.14.0FalseNoneNoneFalseNoneFalse12944.40
3096936106488Nonecode33Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5Each5924.15924.16.0FalseNoneNoneFalseNoneFalse35544.60
3096937106488Nonecode34Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.25 mm nominal dia pipes.Mtr500.85500.85100.0FalseNoneNoneFalseNoneFalse50085.00
3096938106488Nonecode35Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work.100 mm nominal dia Pipes.Mtr976.5976.590.0FalseNoneNoneFalseNoneFalse87885.00
3096939106488Nonecode36Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter.Mtr305.55305.5518.0FalseNoneNoneFalseNoneFalse5499.90
3096940106488Nonecode37Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.Ltr9.459.451000.0FalseNoneNoneFalseNoneFalse9450.00
3096941106488Nonecode38Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :25 mm nominal boreNo605.85605.858.0FalseNoneNoneFalseNoneFalse4846.80
3096942106488Nonecode39Providing and fixing brass bib cock of approved quality : 20 mm nominal bore.No320.25320.2515.0FalseNoneNoneFalseNoneFalse4803.750
3096943106488Nonecode40Providing and fixing brass stop cock of approved quality:20 mm nominal bore.No320.25320.2515.0FalseNoneNoneFalseNoneFalse4803.750
3096944106488Nonecode41Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mmNo1068.91068.94.0FalseNoneNoneFalseNoneFalse4275.60
3096945106488Nonecode42Providing and fixing PTMT towel rail complete with brackets fixed towooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.No520.8520.84.0FalseNoneNoneFalseNoneFalse2083.20
3096946106488Nonecode43Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.No850.5850.510.0FalseNoneNoneFalseNoneFalse8505.00
3096947106488Nonecode44SConcealed Conduit System Supplying heavy PVC condiuit pipe ……mm dia .mm thick confirming to IS 2509 woth suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary 32 mm dia 2.5 mm thickMtr103.0103.0100.0FalseNoneNoneFalseNoneFalse10300.00
3096948106488Nonecode45Concealed Conduit System Supplying heavy gauge PVC Conduit Pipe….dia….mm thick with suitable size bends, metal junction boxes adhesive paste etx. by groove cutting in the wall and fixing by using U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25 mm dia 2 mm thickMtr79.079.0120.0FalseNoneNoneFalseNoneFalse9480.00
3096949106488Nonecode46Supplying and fixing PVC/metal conduit accessories.deep junction box 25mm junction boxEach56.056.030.0FalseNoneNoneFalseNoneFalse1680.00
3096950106488Nonecode47Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 10-12 WayEach261.0261.06.0FalseNoneNoneFalseNoneFalse1566.00
3096951106488Nonecode48Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12 WayEach344.0344.06.0FalseNoneNoneFalseNoneFalse2064.00
3096952106488Nonecode49Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way SwitchEach102.0102.040.0FalseNoneNoneFalseNoneFalse4080.00
3096953106488Nonecode50Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two ModuleEach357.0357.04.0FalseNoneNoneFalseNoneFalse1428.00
3096954106488Nonecode51Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32A DP SwitchEach326.0326.04.0FalseNoneNoneFalseNoneFalse1304.00
3096955106488Nonecode52Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16A Universal SocketEach236.0236.010.0FalseNoneNoneFalseNoneFalse2360.00
3096956106488Nonecode53Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3m from tapping point to out let via switch box.Point269.0269.025.0FalseNoneNoneFalseNoneFalse6725.00
3096957106488Nonecode54Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3m upto 6m from tapping point to out let via switch box.Point379.0379.025.0FalseNoneNoneFalseNoneFalse9475.00
3096958106488Nonecode55Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6m upto 10m from tapping point to out let via switch box.Point555.0555.025.0FalseNoneNoneFalseNoneFalse13875.00
3096959106488Nonecode56Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1 mm2.Mtr19.019.080.0FalseNoneNoneFalseNoneFalse1520.00
3096960106488Nonecode57Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2.Mtr26.026.0100.0FalseNoneNoneFalseNoneFalse2600.00
3096961106488Nonecode58Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2.Mtr42.042.0200.0FalseNoneNoneFalseNoneFalse8400.00
3096962106488Nonecode59Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4.0 mm2.Mtr63.063.0200.0FalseNoneNoneFalseNoneFalse12600.00
3096963106488Nonecode60Supplying of .feet -PVC Batten with integrated LED tube . W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI less than 80. Power Input: 220-240V@ 50/60Hz & Power factor less than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2 - 9/10 WEach551.0551.025.0FalseNoneNoneFalseNoneFalse13775.00
3096964106488Nonecode61Supplying PVC/GI flexible conduit pipe . mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely 25mmMtr22.022.025.0FalseNoneNoneFalseNoneFalse550.00
3096965106488Nonecode62Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' cure, indicator ON/OFF, energy cross-3 with Short circuit breaking cappacity of 10K and complete wiring as required. Confirming to IEC 60898. - 50-63Amps TNP 6-32 A SPEach415.0415.01.0FalseNoneNoneFalseNoneFalse415.00
3096966106488Nonecode63Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' cure, indicator ON/OFF, energy cross-3 with Short circuit breaking cappacity of 10K and complete wiring as required. Confirming to IEC 60898. - 50-63Amps TNP 6-32 A DPEach739.0739.01.0FalseNoneNoneFalseNoneFalse739.00
3096967106488Nonecode64Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm alround with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. 40mm dia 2.9mm thick 2.5 mtr longEach4256.04256.01.0FalseNoneNoneFalseNoneFalse4256.00
3096968106488Nonecode65Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with suitable approved colour powder coated paint.-18SWGSq CM0.380.3810000.0FalseNoneNoneFalseNoneFalse3800.00
3096969106488Nonecode66Supplying . amps rated 3phase with neutral bus bar using required capacity electrolytic alluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary botls,nuts and washers etc., complete.- 100Amps 4x30x6mm Alluminium StripsMtr2465.02465.01.0FalseNoneNoneFalseNoneFalse2465.00
3096970106488Nonecode67Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.- 63AmpsEach401.0401.02.0FalseNoneNoneFalseNoneFalse802.00
3096971106488Nonecode68Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS- 694:2010 4C x 6 mm2Each328.0328.050.0FalseNoneNoneFalseNoneFalse16400.00
3096972106488Nonecode69Providing, supplying to work site,Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications,with testing of as per instructions of engineer incharge of work and latest amendments- 0.50 HP/0.37kW - 5 STG(stage)Each10170.010170.01.0FalseNoneNoneFalseNoneFalse10170.00
3096973106488Nonecode70Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 56" Sweep (1400 mm) Regular modelEach3031.03031.04.0FalseNoneNoneFalseNoneFalse12124.00
3096974106488Nonecode71Supplyingof1440rpmheavydutyexhaustfanwithbracketbladessuitable to operate on 230V 50Hz, AC Supply complete. 12" Sweep (300 mm)Each2969.02969.010.0FalseNoneNoneFalseNoneFalse29690.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17105070170000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17105070170000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17105070170001NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of KPP Portal on or before the last date and time of bid submission.None
17105070170001NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of KPP portal due to internet connectivity issues and technical glitches at bidders end.None
17105070170001NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17105070170001NoneNoneELIGIBILITYConditional tenders will not be accepted.None
17105070170001NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of the tender and the employer will in no case be responsible and liable for those costs.None
17105070170001NoneNoneELIGIBILITYThe cost of the Tender Processing fee shall not be refundableNone
17105070170001NoneNoneELIGIBILITYThe authority reserves the rights to Reject or accept any or all the tenders without assigning any reasonsNone
17105070170001NoneNoneELIGIBILITYThe intending contractors are requested to note that they should abide by the detailed instructions and conditions contained in the respective Standard Tender documents (uploaded)None
17105070170000NoneNoneELIGIBILITYBanker Details for referenceNone
17105070170001NoneNoneELIGIBILITYTenderer in his name should have in the last five years i.e. (2018-19 to 2022-23), Achieved in at least two financial years an annual financial turnover (in all classes of civil engineering construction works only) 100% of Estimate cost.None
17105070170001NoneNoneELIGIBILITYTechnical evaluation will be done as per latest KTPP act.None
17105070170001NoneNoneELIGIBILITYThe successful Tenderer shall deliver to the Employer a Security deposit at the time of Agreement, in the name of the Executive Engineer, Ws & UGD East Division, MCC, Mysore for an amount equivalent to 5% of the Contract price plus additional security for the difference cost (below Estimate Cost) in accordance with the Conditions of Contract.None
17105070170001NoneNoneELIGIBILITYAny dispute regarding this tender appeal should be submitted through KPP PortalNone
17105071300000NoneNoneELIGIBILITYThe EMD will be released only after the Work OrderNone
17105072270000NoneNoneELIGIBILITYAny changes/modifications if any will be notified/ updated through KPP Portal only.None
17105072320000NoneNoneELIGIBILITYAs per PWD Code 251. Jurisdiction: Contractors registered under Class I and II may tender for works anywhere in the state. Contractors registered under Class III may tender for works within the districts of the Public Works Department circles where in they are registered. Contractors registered under Class IV may tender for works within the district or within the division whichever is applicable, where they are registered. These registrations are valid for all works undertaken by all the Government departments, Government undertakings in the respective jurisdictions. No separate registration is required in other Government departments and Government undertakings. This registration procedure is based on the single window concept.None
17105072560000NoneNoneELIGIBILITYPayment for the work is done under SBM grant. Bidder should accept the payment procedures as prescribed time to time by the Mysore City Corporation.None
17105072640000NoneNoneELIGIBILITYThis bid is exclusive of taxes, GST will be paid separatelyNone
17105072720000NoneNoneELIGIBILITYTenderer in his name should have in the last five years i.e. (2018-19 to 2022-23), satisfactorily completed as prime contractor, at least one similar nature of work of value not less than 50% of Estimate cost.None
preQualCriterionListNone
technicalCriterionListNone
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover Certificate with UDINTrueTechnical Bid
PWD Registration CertificateTrueTechnical Bid
Similar Nature of Work Done CertificateTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone