3096756 | 106479 | None | code01 | Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. 3.00 HP - 90 LPM at 66 m = 10 STG Outlet Dia - 2.00" | Nos | 29518.65 | 29518.65 | 1.0 | False | None | None | False | None | False | 29518.65 | 0 |
3096757 | 106479 | None | code02 | Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete.. Heavy Duty GI pipe of 32mm dia | Mtr | 449.4 | 449.4 | 12.0 | False | None | None | False | None | False | 5392.8 | 0 |
3096758 | 106479 | None | code03 | Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x2.5 Sqm | Mtr | 89.25 | 89.25 | 90.0 | False | None | None | False | None | False | 8032.5 | 0 |
3096759 | 106479 | None | code04 | Cutting and threading G.I. pipes for pump fitting, public fountains with appurtenances., where the length of pipe laid is less than 6 metres Pipes of dia 32mm to 80mm | Nos | 338.1 | 338.1 | 4.0 | False | None | None | False | None | False | 1352.4 | 0 |
3096760 | 106479 | None | code05 | Clamps & M.S stay incl. b&n for 50mm | Each | 32.55 | 32.55 | 8.0 | False | None | None | False | None | False | 260.4 | 0 |
3096761 | 106479 | None | code06 | Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments. Size 50 mm | Nos | 1312.5 | 1312.5 | 1.0 | False | None | None | False | None | False | 1312.5 | 0 |
3096762 | 106479 | None | code07 | Supply and delivery at site wrought middle steel (galvanized) GI plugs confirming to IS 1239-II, 1991 with latest amendments if any For 50 mm dia GI Union | Nos | 280.35 | 280.35 | 1.0 | False | None | None | False | None | False | 280.35 | 0 |
3096763 | 106479 | None | code08 | Supply and delivery at site wrought middle steel (galvanized) GI plugs confirming to IS 1239-II, 1991 with latest amendments if any. For 50 mm dia GI Plugs | Nos | 208.95 | 208.95 | 1.0 | False | None | None | False | None | False | 208.95 | 0 |
3096764 | 106479 | None | code09 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. | Job | 6825.0 | 6825.0 | 1.0 | False | None | None | False | None | False | 6825.0 | 0 |
3096765 | 106479 | None | code10 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m | Cum | 254.1 | 254.1 | 0.3375 | False | None | None | False | None | False | 85.75875 | 0 |
3096766 | 106479 | None | code11 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap /basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6788.96 | 6788.96 | 0.0675 | False | None | None | False | None | False | 458.2548 | 0 |
3096767 | 106479 | None | code12 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. . B74 | Cum | 8631.0 | 8631.0 | 0.483 | False | None | None | False | None | False | 4168.773 | 0 |
3096768 | 106479 | None | code13 | Providing Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement :3 coarse sand), finished with a floating coat of neat cement.18mm thick | Sqm | 506.1 | 506.1 | 6.99 | False | None | None | False | None | False | 3537.639 | 0 |
3096769 | 106479 | None | code14 | Supply and fixing iron frame work fabricated out of MS angle iron and MS flat with bolt and nuts washers etc and painted with two coat of red oxide and the two coats of appprovd paint | Nos | 240.0 | 240.0 | 4.0 | False | None | None | False | None | False | 960.0 | 0 |
3096770 | 106479 | None | code15 | Fabricating supplying and mounting MS box made out SWG suitable for floor/wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable sizecl amps wthnecessary cable entry pipe with gland and box should be finished with 7tank streatment with powder coated paint and finally finished with approved colour etc., complete. 16 SWG | Sq CM | 0.45 | 0.45 | 25000.0 | False | None | None | False | None | False | 11250.0 | 0 |
3096771 | 106479 | None | code16 | Supplying and fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers etc., complete., 63 Amps | Nos | 421.05 | 421.05 | 3.0 | False | None | None | False | None | False | 1263.15 | 0 |
3096772 | 106479 | None | code17 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing aterials and C type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10 K and complete wiring as requried. 50 : 63 Amps TPN | Nos | 3242.4 | 3242.4 | 1.0 | False | None | None | False | None | False | 3242.4 | 0 |
3096773 | 106479 | None | code18 | Supplying, fixing and wiring Earth Leakage Miniature circuit breaker (ELMCB) 240/450V upto 300mA sensitivity on existing wood/panel board. 50 : 32 : 40 Amps 4 pole | Nos | 2800.0 | 2800.0 | 1.0 | False | None | None | False | None | False | 2800.0 | 0 |
3096774 | 106479 | None | code19 | Supplying, fixing and wiring heavy duty low voltage capacitors confirming to IS 2834, 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery.Cost per KVAR | Kvar | 504.0 | 504.0 | 2.0 | False | None | None | False | None | False | 1008.0 | 0 |
3096775 | 106479 | None | code20 | Supplying fully automatic star-delta starter unit push button type with suitable wires 3 contactors, one adjustable thermal timer mounted on a common base plate held in steel enclosure for use on 400/440 volts 3 phase and wired after fixing to the wooden board for motor. upto 12.5 HP | Each | 7827.75 | 7827.75 | 1.0 | False | None | None | False | None | False | 7827.75 | 0 |
3096776 | 106479 | None | code21 | Supplying and fixing single phase preventer using necessary wires over an existing panel board suitable for motor upto 20 HP capacities. | Each | 949.22 | 949.22 | 1.0 | False | None | None | False | None | False | 949.22 | 0 |
3096777 | 106479 | None | code22 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc., using 40mm dia 2.9mm thick 2.5 mtr. Long GI Pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm alround with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. | Nos | 4468.8 | 4468.8 | 2.0 | False | None | None | False | None | False | 8937.6 | 0 |
3096778 | 106479 | None | code23 | Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. In Ordinary Soil | Mtr | 273.0 | 273.0 | 26.0 | False | None | None | False | None | False | 7098.0 | 0 |
3096779 | 106479 | None | code24 | Supplying of 1.1 KV LT UG Cable XLPE or heat resistant PVC Insulated, PVC extruded, inner sheath armoured, UG LT cable as per IS - 1554 (part-1) or IS - 7098 part-1, Armouring strip thickness in average + 5 percentage and resistivity 14 Ohms/kms (max) as per IS-3975. 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) | Mtr | 148.93 | 148.93 | 30.0 | False | None | None | False | None | False | 4467.9 | 0 |
3096780 | 106479 | None | code25 | Labour charges for Laying of 1.1 KV class UG cable in existing trench GI pipe/ store ware pipe, on wall/ on pole as required.6 sqmm to 16 sqmm. | Mtr | 11.88 | 11.88 | 30.0 | False | None | None | False | None | False | 356.4 | 0 |
3096781 | 106479 | None | code26 | Providing and filling sand in excavated trench to cover already laid UG to a depth of 150 mm all-round the cable. | Mtr | 100.0 | 100.0 | 18.0 | False | None | None | False | None | False | 1800.0 | 0 |
3096782 | 106479 | None | code27 | Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete. Medium Duty GI pipe of 40mm dia | Mtr | 512.4 | 512.4 | 2.0 | False | None | None | False | None | False | 1024.8 | 0 |
3096783 | 106479 | None | code28 | Supplying and fixing LT cast iron pot heads suitable for 1.1 KV class UG cable filled with necessary bitumen/ insulating compound complete with terminals, clamps, bolts,nuts and washers etc., 16 sqmm | Nos | 270.0 | 270.0 | 1.0 | False | None | None | False | None | False | 270.0 | 0 |
3096784 | 106479 | None | code29 | Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63A three phase 4 wire whole current class-1 Accuracy Energy Meter | Each | 5990.25 | 5990.25 | 4.0 | False | None | None | False | None | False | 23961.0 | 0 |
3096785 | 106479 | None | code30 | Fixing of Energy Meter to IP Set, (where there is no pumphouse) where power supply is availed directly from the Pole to the IP set and weather proof meter housing box is required (including cost of WP box). | Each | 4784.85 | 4784.85 | 1.0 | False | None | None | False | None | False | 4784.85 | 0 |
3096786 | 106479 | None | code31 | Cutting asphalt Road surface by Machine cutting to demarcate the trench width of the surface. | Cum | 935.55 | 935.55 | 16.8 | False | None | None | False | None | False | 15717.24 | 0 |
3096787 | 106479 | None | code32 | Cutting road surfaces for pipeline trenches and disposing of the excavated stuff as directed including barricading, danger lighting etc. in the classifications for:Macadam Road. | Cum | 856.8 | 856.8 | 25.2 | False | None | None | False | None | False | 21591.36 | 0 |
3096788 | 106479 | None | code33 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m. | Cum | 508.2 | 508.2 | 201.6 | False | None | None | False | None | False | 102453.12 | 0 |
3096789 | 106479 | None | code34 | Providing, laying and jointing HDPE pipes of specified grade andconforming to IS 4984-2016 with latest ammendments and conveyingto work site including loading and unloading at both destinations androlling and lowering into trenches, laying true to line and jointing ofpipes and specials with electrofusion welding, giving hydraulic testas per relevant ISS with all lead and lifts including encasing the pipealround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. Therate is exclusive of required specials and fittings wherever necessarylike saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete(Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0 HDPE Grade PE80-PN6.0, 63mm dia | Mtr | 198.45 | 198.45 | 280.0 | False | None | None | False | None | False | 55566.0 | 0 |
3096790 | 106479 | None | code35 | Providing and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of Ductile Iron (DI) conforming ti IS-1865 with the latest amendments and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 with the latest amendments only. The stem sealing should be with toroidal sealing rings (minimum 2 " O " rings). Body and bonnet should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. For PN-10: (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) etc. complete For Suilce Valve of PN10.0 and 80mm | Each | 10912.65 | 10912.65 | 2.0 | False | None | None | False | None | False | 21825.3 | 0 |
3096791 | 106479 | None | code36 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications | Cum | 168.0 | 168.0 | 201.6 | False | None | None | False | None | False | 33868.8 | 0 |