1710505950000 | 0 | None | None | Water supply/sewage lines | Construction of Concrete Guttur Beam and Providing Electricity Connection to tank no.01 at German press premises, Mysuru | 1035200.27 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3096345 | 106470 | None | code01 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6823.95 | 6823.95 | 49.25 | False | None | None | False | None | False | 336079.5375 | 0 | 3096346 | 106470 | None | code02 | Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding RCC Beams, Lintels & Troughs of Aqueducts | Cum | 4094.37 | 4094.37 | 49.25 | False | None | None | False | None | False | 201647.7225 | 0 | 3096347 | 106470 | None | code03 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 339.15 | 339.15 | 294.98 | False | None | None | False | None | False | 100042.467 | 0 | 3096348 | 106470 | None | code04 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per irections of Engineer-in-charge | Sqm | 297.15 | 297.15 | 541.01 | False | None | None | False | None | False | 160761.1215 | 0 | 3096349 | 106470 | None | code05 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 182.7 | 182.7 | 444.89 | False | None | None | False | None | False | 81281.403 | 0 | 3096350 | 106470 | None | code06 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in
depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. (30*.5*.6) | Cum | 508.2 | 508.2 | 9.0 | False | None | None | False | None | False | 4573.8 | 0 | 3096351 | 106470 | None | code07 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 16 Sqmm, 4 Core, (13 GI Strips - 4 x 0.8 mm) | Km | 204078.0 | 204078.0 | 0.06 | False | None | None | False | None | False | 12244.68 | 0 | 3096352 | 106470 | None | code08 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 to 25 Sqmm | Km | 16159.0 | 16159.0 | 0.06 | False | None | None | False | None | False | 969.54 | 0 | 3096353 | 106470 | None | code09 | Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Meadium Duty GI Pipe etc. complete.GI pipe of 40mm dia | Mtr | 250.0 | 250.0 | 8.0 | False | None | None | False | None | False | 2000.0 | 0 | 3096354 | 106470 | None | code10 | PVC pipes 50mm dia., 6 kg/sqcm & class 5 for Road crossing | Mtr | 88.0 | 88.0 | 30.0 | False | None | None | False | None | False | 2640.0 | 0 | 3096355 | 106470 | None | code11 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 mm2 | Mtr | 59.0 | 59.0 | 60.0 | False | None | None | False | None | False | 3540.0 | 0 | 3096356 | 106470 | None | code12 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2 | Mtr | 40.0 | 40.0 | 30.0 | False | None | None | False | None | False | 1200.0 | 0 | 3096357 | 106470 | None | code13 | Supplying heavy gauge PVC conduit pipe 19/20 mm dia2 mm thick confirming to IS2509 withsuitable size bends, junction boxes,adhesive paste etc,and fixing usingin verted wood plugs in case of RCC ceiling and RCCwall/stone structure or rawl plug s in case of brick walls | Mtr | 68.0 | 68.0 | 36.0 | False | None | None | False | None | False | 2448.0 | 0 | 3096358 | 106470 | None | code14 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70percentage, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection Min 5KV along with Over voltage/ Overload, short circuit/ miss wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiency greater than 1301m/w, nominal CRI greater than 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency and Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect LED Streetlight 90 W | No | 7777.0 | 7777.0 | 10.0 | False | None | None | False | None | False | 77770.0 | 0 | 3096359 | 106470 | None | code15 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70percentage, CCT greater than 5500K, IP 66 optical and electrical compartment and impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiency greater than 1301m/w, nominal CRI greater than 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency and Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ LED Floodlight 100W | No | 8172.0 | 8172.0 | 3.0 | False | None | None | False | None | False | 24516.0 | 0 | 3096360 | 106470 | None | code16 | Supplying and Fixing mm dia clamp AGI pipe bracket up to 2.7meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mml ength is fixed for fixing MV/SV/MH/FTL streetligh tfitting of all capacities on rail/RCC/wall/tubularpole,Using 32mm dia G.I.Pipe | No | 1136.0 | 1136.0 | 10.0 | False | None | None | False | None | False | 11360.0 | 0 | 3096361 | 106470 | None | code17 | Point wiring using Copper wire without switch. Long point above 3Mtr upto 6Mtr from tapping point to outlet via switch box | Point | 379.0 | 379.0 | 10.0 | False | None | None | False | None | False | 3790.0 | 0 | 3096362 | 106470 | None | code18 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groovecuttingin Brick/C.C wall,including necessary rawlplugs,Machine/NF screws etc., complete. 10-12way | Each | 277.0 | 277.0 | 1.0 | False | None | None | False | None | False | 277.0 | 0 | 3096363 | 106470 | None | code19 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos.of machine screws,bolts nutsetc.,complete on the existing metal/PVC box.10-12 module | Each | 363.0 | 363.0 | 1.0 | False | None | None | False | None | False | 363.0 | 0 | 3096364 | 106470 | None | code20 | 6A One Way Switch | Each | 88.0 | 88.0 | 10.0 | False | None | None | False | None | False | 880.0 | 0 | 3096365 | 106470 | None | code21 | 6A Three Way socket | Each | 162.0 | 162.0 | 2.0 | False | None | None | False | None | False | 324.0 | 0 | 3096366 | 106470 | None | code22 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards 6-32 A DP | Each | 1103.0 | 1103.0 | 2.0 | False | None | None | False | None | False | 2206.0 | 0 | 3096367 | 106470 | None | code23 | Supplying and fixing regular MCB distribution boards 8 Way SP & N | Each | 1302.0 | 1302.0 | 1.0 | False | None | None | False | None | False | 1302.0 | 0 | 3096368 | 106470 | None | code24 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200 mm) Regular model | Each | 2984.0 | 2984.0 | 1.0 | False | None | None | False | None | False | 2984.0 | 0 |
|