3095829 | 106455 | None | code01 | Construction of two class rooms to GHPS @ Thondehalu village:-Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-charge | Cum | 605.35 | 605.35 | 20.475 | False | None | None | False | None | False | 12394.54125 | 0 |
3095830 | 106455 | None | code02 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineerin-charge | Cum | 1723.45 | 1723.45 | 25.45 | False | None | None | False | None | False | 43861.8025 | 0 |
3095831 | 106455 | None | code03 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. | Cum | 254.1 | 254.1 | 61.52 | False | None | None | False | None | False | 15632.232 | 0 |
3095832 | 106455 | None | code04 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. | Cum | 271.95 | 271.95 | 18.25 | False | None | None | False | None | False | 4963.0875 | 0 |
3095833 | 106455 | None | code05 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6288.45 | 6288.45 | 9.2 | False | None | None | False | None | False | 57853.74 | 0 |
3095834 | 106455 | None | code06 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6852.38 | 6852.38 | 12.82 | False | None | None | False | None | False | 87847.5116 | 0 |
3095835 | 106455 | None | code07 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11309.76 | 11309.76 | 1.48 | False | None | None | False | None | False | 16738.4448 | 0 |
3095836 | 106455 | None | code08 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 12214.76 | 12214.76 | 4.05 | False | None | None | False | None | False | 49469.778 | 0 |
3095837 | 106455 | None | code09 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10777.73 | 10777.73 | 14.96 | False | None | None | False | None | False | 161234.8408 | 0 |
3095838 | 106455 | None | code10 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11496.24 | 11496.24 | 8.23 | False | None | None | False | None | False | 94614.0552 | 0 |
3095839 | 106455 | None | code11 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10418.47 | 10418.47 | 0.28 | False | None | None | False | None | False | 2917.1716 | 0 |
3095840 | 106455 | None | code12 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10777.73 | 10777.73 | 17.55 | False | None | None | False | None | False | 189149.1615 | 0 |
3095841 | 106455 | None | code13 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Buildings | Tonne | 93929.85 | 93929.85 | 5.8 | False | None | None | False | None | False | 544793.13 | 0 |
3095842 | 106455 | None | code14 | Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 9094.05 | 9094.05 | 9.7 | False | None | None | False | None | False | 88212.285 | 0 |
3095843 | 106455 | None | code15 | Providing Brick work with common burnt clay Non Modular bricks of
class designation 3.5 in superstructure above plinth level in all shapes and
sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of
all materials, labour, scaffolding and usage charges of machinery & other
incidental charges complete as per the direction of engineer incharge of
work. | Cum | 8367.45 | 8367.45 | 25.75 | False | None | None | False | None | False | 215461.8375 | 0 |
3095844 | 106455 | None | code16 | Providing Half brick masonry with common burnt clay Non Modular
bricks of class designation 3.5 in superstructure above plinth level up
to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including
cost of all materials, labour, scaffolding and usage charges of machinery
& other incidental charges complete as per the direction of engineer
incharge of work. | Sqm | 1113.0 | 1113.0 | 35.26 | False | None | None | False | None | False | 39244.38 | 0 |
3095845 | 106455 | None | code17 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 279.3 | 279.3 | 37.83 | False | None | None | False | None | False | 10565.919 | 0 |
3095846 | 106455 | None | code18 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 497.7 | 497.7 | 119.62 | False | None | None | False | None | False | 59534.874 | 0 |
3095847 | 106455 | None | code19 | Providing and fixing 1mm thick M.S. sheet door with frame of
40x40x6 mm angle iron and 3 mm M.S. gusset plates at the
junctions and corners, all necessary fittings complete, including
applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as p | Sqm | 4454.1 | 4454.1 | 18.0 | False | None | None | False | None | False | 80173.8 | 0 |
3095848 | 106455 | None | code20 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding14.3 | Kgs | 176.4 | 176.4 | 396.9 | False | None | None | False | None | False | 70013.16 | 0 |
3095849 | 106455 | None | code21 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:2:4 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6463.8 | 6463.8 | 19.34 | False | None | None | False | None | False | 125009.892 | 0 |
3095850 | 106455 | None | code22 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. | Sqm | 2994.6 | 2994.6 | 116.42 | False | None | None | False | None | False | 348631.332 | 0 |
3095851 | 106455 | None | code23 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 292.95 | 292.95 | 132.22 | False | None | None | False | None | False | 38733.849 | 0 |
3095852 | 106455 | None | code24 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Cum | 349.65 | 349.65 | 304.64 | False | None | None | False | None | False | 106517.376 | 0 |
3095853 | 106455 | None | code25 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 87.15 | 87.15 | 238.08 | False | None | None | False | None | False | 20748.672 | 0 |
3095854 | 106455 | None | code26 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 133.35 | 133.35 | 542.72 | False | None | None | False | None | False | 72371.712 | 0 |
3095855 | 106455 | None | code27 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kgs | 136.5 | 136.5 | 75.6 | False | None | None | False | None | False | 10319.4 | 0 |
3095856 | 106455 | None | code28 | Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | cm | 4.2 | 4.2 | 5000.0 | False | None | None | False | None | False | 21000.0 | 0 |
3095857 | 106455 | None | code29 | Providing and laying 60mm thick factory made cement concrete paver
block of approved shape and colour of M -30 grade made of C&D waste
by block making machine with vibratory compaction laid in required
pattern and including over 50mm thick compacted bed of coarse sand,
filling the joints with fine sand etc. all complete as per the direction of
Engineer-in-charge. | Cum | 840.0 | 840.0 | 60.0 | False | None | None | False | None | False | 50400.0 | 0 |
3095858 | 106455 | None | code30 | Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2mm thick | m | 66.0 | 66.0 | 120.0 | False | None | None | False | None | False | 7920.0 | 0 |
3095859 | 106455 | None | code31 | Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25mm dia 2mm thick | m | 78.0 | 78.0 | 40.0 | False | None | None | False | None | False | 3120.0 | 0 |
3095860 | 106455 | None | code32 | Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 75x75x65mm | Each | 106.0 | 106.0 | 1.0 | False | None | None | False | None | False | 106.0 | 0 |
3095861 | 106455 | None | code33 | Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.200x90x65mm | Each | 179.0 | 179.0 | 3.0 | False | None | None | False | None | False | 537.0 | 0 |
3095862 | 106455 | None | code34 | Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 180X90X65mm | Each | 161.0 | 161.0 | 1.0 | False | None | None | False | None | False | 161.0 | 0 |
3095863 | 106455 | None | code35 | Supplying and fixing PVC/metal conduit Deep junction box 19/20mm Deep Junction Box | Each | 49.0 | 49.0 | 5.0 | False | None | None | False | None | False | 245.0 | 0 |
3095864 | 106455 | None | code36 | Supplying and fixing PVC/metal conduit Deep junction box 25mm Deep Junction Box | Each | 56.0 | 56.0 | 1.0 | False | None | None | False | None | False | 56.0 | 0 |
3095865 | 106455 | None | code37 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. | m | 29.0 | 29.0 | 30.0 | False | None | None | False | None | False | 870.0 | 0 |
3095866 | 106455 | None | code38 | Supplying And Fixing Metal Fan Box with Round Hook. | Nos | 160.0 | 160.0 | 4.0 | False | None | None | False | None | False | 640.0 | 0 |
3095867 | 106455 | None | code39 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. A Short piont up to 3 m from tapping piont out let via switch. | Point | 285.0 | 285.0 | 8.0 | False | None | None | False | None | False | 2280.0 | 0 |
3095868 | 106455 | None | code40 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. A medium piont above 3m to 6 m from tapping piont out let via switch. | Point | 394.0 | 394.0 | 6.0 | False | None | None | False | None | False | 2364.0 | 0 |
3095869 | 106455 | None | code41 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.A Long point above 6m upto 10m from tapping point to out let via switch | Point | 570.0 | 570.0 | 2.0 | False | None | None | False | None | False | 1140.0 | 0 |
3095870 | 106455 | None | code42 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.1.5 Sqmm | m | 26.0 | 26.0 | 140.0 | False | None | None | False | None | False | 3640.0 | 0 |
3095871 | 106455 | None | code43 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.5 Sqmm | m | 42.0 | 42.0 | 10.0 | False | None | None | False | None | False | 420.0 | 0 |
3095872 | 106455 | None | code44 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.4 Sqmm | m | 63.0 | 63.0 | 8.0 | False | None | None | False | None | False | 504.0 | 0 |
3095873 | 106455 | None | code45 | Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box.1 to 3 Module | Each | 137.0 | 137.0 | 2.0 | False | None | None | False | None | False | 274.0 | 0 |
3095874 | 106455 | None | code46 | Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box.4 Module | Each | 175.0 | 175.0 | 4.0 | False | None | None | False | None | False | 700.0 | 0 |
3095875 | 106455 | None | code47 | Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box.8 Module | Each | 234.0 | 234.0 | 1.0 | False | None | None | False | None | False | 234.0 | 0 |
3095876 | 106455 | None | code48 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps one way | Each | 102.0 | 102.0 | 2.0 | False | None | None | False | None | False | 204.0 | 0 |
3095877 | 106455 | None | code49 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.16Amps one way switch | Each | 177.0 | 177.0 | 2.0 | False | None | None | False | None | False | 354.0 | 0 |
3095878 | 106455 | None | code50 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6/16Amps universal socket | Each | 156.0 | 156.0 | 4.0 | False | None | None | False | None | False | 624.0 | 0 |
3095879 | 106455 | None | code51 | Supplying and fixing 32A security and energy saving DPswitch with key tag suitable to operate on 230 V, 50Hz AC supply & completely wired on existing box. | Each | 646.0 | 646.0 | 1.0 | False | None | None | False | None | False | 646.0 | 0 |
3095880 | 106455 | None | code52 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 .6-32 Amps SP | Each | 415.0 | 415.0 | 1.0 | False | None | None | False | None | False | 415.0 | 0 |
3095881 | 106455 | None | code53 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 .6-32 Amps DP | Each | 739.0 | 739.0 | 1.0 | False | None | None | False | None | False | 739.0 | 0 |
3095882 | 106455 | None | code54 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.12 Way SP & N | Each | 3088.0 | 3088.0 | 1.0 | False | None | None | False | None | False | 3088.0 | 0 |
3095883 | 106455 | None | code55 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. | Each | 9255.0 | 9255.0 | 1.0 | False | None | None | False | None | False | 9255.0 | 0 |
3095884 | 106455 | None | code56 | Supplying and fixing Electronic Trivector Meter (ETV) suitable for operation LT operation and -CT operated meter in polycarbonate body in class 0.5 accuracy as per IS 14697 and completely wired. | Each | 4390.0 | 4390.0 | 1.0 | False | None | None | False | None | False | 4390.0 | 0 |
3095885 | 106455 | None | code57 | Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.250Amps 4x30x10mm Aluminium Strips | m | 3435.0 | 3435.0 | 1.0 | False | None | None | False | None | False | 3435.0 | 0 |
3095886 | 106455 | None | code58 | Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fighting 1 x4'- 20/22 w | Each | 690.0 | 690.0 | 8.0 | False | None | None | False | None | False | 5520.0 | 0 |
3095887 | 106455 | None | code59 | Supplying & Fixing of 70-150 Watts lamp holder 2 Pin | Nos | 63.0 | 63.0 | 8.0 | False | None | None | False | None | False | 504.0 | 0 |
3095888 | 106455 | None | code60 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. | Each | 122.0 | 122.0 | 8.0 | False | None | None | False | None | False | 976.0 | 0 |
3095889 | 106455 | None | code61 | Fixing all types and all capacities of 1'x4' / 2'x2' LED Light fittings indoor on the wall/ceiling/rafters / girders with necessary supporting frame, using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. | Each | 490.0 | 490.0 | 8.0 | False | None | None | False | None | False | 3920.0 | 0 |
3095890 | 106455 | None | code62 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts,50 cycles. Single phase AC supply conforming to ISS-3741979 and with double ball bearing system. | Each | 2984.0 | 2984.0 | 4.0 | False | None | None | False | None | False | 11936.0 | 0 |
3095891 | 106455 | None | code63 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts,50 cycles. Single phase AC supply conforming to ISS-3741979 and with double ball bearing system.48" Sweep (1200mm) Regular model | Each | 315.0 | 315.0 | 4.0 | False | None | None | False | None | False | 1260.0 | 0 |
3095892 | 106455 | None | code64 | Providing and Installation of Multimedia Projector with having resolution of XGA 1024 X 768 or Higher, Brightness of 3700 Lumens or higher, Lamp life upto 10,000 hours , Contrast Ratio 16,000:1 or More, Video Capability NTSc,PAL with HDMI 720p,576p,576i,4809,480i,1080i,1080p Audio Out Connector with 16watt Audio Output or higher Aspect Ratio of 4:3 and 16:9 Display Input VGA x 2, HDMI x 2, USB, Composite A/V, MHL, WiFi, Connectivity of HDMI/VGA,MHL,WiFi with 3 Years Comprehensive on Site Warranty,3000 Hours on light Source, with Accessories of Power Cord, Mouse Control Accesorry for Computer. HDMI,VGA,Audio cables-4M Length, with Full Function Remote with Auto Shutoff Functionality to Save Lamp life When Projectors control are Not Operated after a Certain Period of Tim | Each | 41948.0 | 41948.0 | 1.0 | False | None | None | False | None | False | 41948.0 | 0 |
3095893 | 106455 | None | code65 | Providing Remote controlled Projector Screen of Size 120 Inches Diagonally | Each | 24998.0 | 24998.0 | 1.0 | False | None | None | False | None | False | 24998.0 | 0 |