3088333 | 106179 | None | code01 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 313.95 | 313.95 | 197.37 | False | None | None | False | None | False | 61964.3115 | 0 |
3088334 | 106179 | None | code02 | Providing and Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications. | Cum | 2816.1 | 2816.1 | 19.94 | False | None | None | False | None | False | 56153.034 | 0 |
3088335 | 106179 | None | code03 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6288.45 | 6288.45 | 35.07 | False | None | None | False | None | False | 220535.9415 | 0 |
3088336 | 106179 | None | code04 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 55.16 | False | None | None | False | None | False | 370038.102 | 0 |
3088337 | 106179 | None | code05 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7129.46 | 7129.46 | 23.33 | False | None | None | False | None | False | 166330.3018 | 0 |
3088338 | 106179 | None | code06 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11025.63 | 11025.63 | 4.98 | False | None | None | False | None | False | 54907.6374 | 0 |
3088339 | 106179 | None | code07 | RCC wworks M-20 (For Plinth beams) Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 9772.35 | 9772.35 | 7.66 | False | None | None | False | None | False | 74856.201 | 0 |
3088340 | 106179 | None | code08 | For Columns above plinth: Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11505.27 | 11505.27 | 6.89 | False | None | None | False | None | False | 79271.3103 | 0 |
3088341 | 106179 | None | code09 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 279.3 | 279.3 | 121.11 | False | None | None | False | None | False | 33826.023 | 0 |
3088342 | 106179 | None | code10 | Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 497.7 | 497.7 | 158.33 | False | None | None | False | None | False | 78800.841 | 0 |
3088343 | 106179 | None | code11 | For Lintel, Roof bema, Roof slab and Staircase: Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10385.76 | 10385.76 | 12.44 | False | None | None | False | None | False | 129198.8544 | 0 |
3088344 | 106179 | None | code12 | Additionalities for Formwork, Centering and scaffolding 50% for Roof | Cum | 10207.05 | 10207.05 | 22.47 | False | None | None | False | None | False | 229352.4135 | 0 |
3088345 | 106179 | None | code13 | For Chejjas: Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10094.18 | 10094.18 | 1.22 | False | None | None | False | None | False | 12314.8996 | 0 |
3088346 | 106179 | None | code14 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6527.85 | 6527.85 | 1.15 | False | None | None | False | None | False | 7507.0275 | 0 |
3088347 | 106179 | None | code15 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | Kgs | 100.8 | 100.8 | 6385.6 | False | None | None | False | None | False | 643668.48 | 0 |
3088348 | 106179 | None | code16 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8367.45 | 8367.45 | 86.51 | False | None | None | False | None | False | 723868.0995 | 0 |
3088349 | 106179 | None | code17 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kgs | 176.4 | 176.4 | 519.75 | False | None | None | False | None | False | 91683.9 | 0 |
3088350 | 106179 | None | code18 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 309.75 | 309.75 | 442.38 | False | None | None | False | None | False | 137027.205 | 0 |
3088351 | 106179 | None | code19 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge. | Sqm | 349.65 | 349.65 | 501.31 | False | None | None | False | None | False | 175283.0415 | 0 |
3088352 | 106179 | None | code20 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 105.0 | 105.0 | 622.13 | False | None | None | False | None | False | 65323.65 | 0 |
3088353 | 106179 | None | code21 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 133.35 | 133.35 | 622.13 | False | None | None | False | None | False | 82961.0355 | 0 |
3088354 | 106179 | None | code22 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 182.7 | 182.7 | 335.88 | False | None | None | False | None | False | 61365.276 | 0 |
3088355 | 106179 | None | code23 | Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm | Sqm | 1202.25 | 1202.25 | 154.02 | False | None | None | False | None | False | 185170.545 | 0 |
3088356 | 106179 | None | code24 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. | Sqm | 1129.8 | 1129.8 | 19.76 | False | None | None | False | None | False | 22324.848 | 0 |
3088357 | 106179 | None | code25 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg/m2, including pointing in white cement mixed with pigment of matching shade complete. | Sqm | 1161.3 | 1161.3 | 60.82 | False | None | None | False | None | False | 70630.266 | 0 |
3088358 | 106179 | None | code26 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 130412.1 | 130412.1 | 0.41 | False | None | None | False | None | False | 53468.961 | 0 |
3088359 | 106179 | None | code27 | Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ) | Sqm | 7241.85 | 7241.85 | 6.3 | False | None | None | False | None | False | 45623.655 | 0 |
3088360 | 106179 | None | code28 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size-1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 5274.15 | 5274.15 | 23.4 | False | None | None | False | None | False | 123415.11 | 0 |
3088361 | 106179 | None | code29 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. | Sqm | 333.9 | 333.9 | 11.4 | False | None | None | False | None | False | 3806.46 | 0 |
3088362 | 106179 | None | code30 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. with both side prelam | Sqm | 2484.3 | 2484.3 | 3.15 | False | None | None | False | None | False | 7825.545 | 0 |
3088363 | 106179 | None | code31 | Electrical: Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19/20 mm dia 2 mm thick | Mtr | 61.0 | 61.0 | 200.0 | False | None | None | False | None | False | 12200.0 | 0 |
3088364 | 106179 | None | code32 | Supplying heavy gauge PVC conduit pipe ....... dia mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25 mm dia 2 mm thick | Mtr | 70.0 | 70.0 | 120.0 | False | None | None | False | None | False | 8400.0 | 0 |
3088365 | 106179 | None | code33 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 100 x 75 x 65 mm | Each | 112.0 | 112.0 | 8.0 | False | None | None | False | None | False | 896.0 | 0 |
3088366 | 106179 | None | code34 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 180 x 90 x 65 mm | Each | 155.0 | 155.0 | 8.0 | False | None | None | False | None | False | 1240.0 | 0 |
3088367 | 106179 | None | code35 | Supplying and fixing PVC/metal conduit Deep junction box 19/20 mm deep Junction box | Each | 49.0 | 49.0 | 12.0 | False | None | None | False | None | False | 588.0 | 0 |
3088368 | 106179 | None | code36 | Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction box | Each | 51.0 | 51.0 | 6.0 | False | None | None | False | None | False | 306.0 | 0 |
3088369 | 106179 | None | code37 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. upto 50 mm conduit in brick wall | Mtr | 21.0 | 21.0 | 60.0 | False | None | None | False | None | False | 1260.0 | 0 |
3088370 | 106179 | None | code38 | Supplying and fixing metal fan box with round Honk. | Nos | 85.0 | 85.0 | 16.0 | False | None | None | False | None | False | 1360.0 | 0 |
3088371 | 106179 | None | code39 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3m from tapping point to out let via switch | Point | 251.0 | 251.0 | 12.0 | False | None | None | False | None | False | 3012.0 | 0 |
3088372 | 106179 | None | code40 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 6m from tapping point to out let via switch | Point | 361.0 | 361.0 | 6.0 | False | None | None | False | None | False | 2166.0 | 0 |
3088373 | 106179 | None | code41 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm | Mtr | 26.0 | 26.0 | 300.0 | False | None | None | False | None | False | 7800.0 | 0 |
3088374 | 106179 | None | code42 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5sqmm | Mtr | 40.0 | 40.0 | 200.0 | False | None | None | False | None | False | 8000.0 | 0 |
3088375 | 106179 | None | code43 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module | Each | 125.0 | 125.0 | 10.0 | False | None | None | False | None | False | 1250.0 | 0 |
3088376 | 106179 | None | code44 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module | Each | 200.0 | 200.0 | 10.0 | False | None | None | False | None | False | 2000.0 | 0 |
3088377 | 106179 | None | code45 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch | Each | 88.0 | 88.0 | 20.0 | False | None | None | False | None | False | 1760.0 | 0 |
3088378 | 106179 | None | code46 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator | Each | 313.0 | 313.0 | 16.0 | False | None | None | False | None | False | 5008.0 | 0 |
3088379 | 106179 | None | code47 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16A One Way Switch | Each | 249.0 | 249.0 | 8.0 | False | None | None | False | None | False | 1992.0 | 0 |
3088380 | 106179 | None | code48 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16A Universal Socket | Each | 249.0 | 249.0 | 8.0 | False | None | None | False | None | False | 1992.0 | 0 |
3088381 | 106179 | None | code49 | Supplying and fixing 32A security and energy saving DP switch with key tag suitable to operate on 230 V, 50Hz AC
supply & completely wired on existing box. | Each | 747.0 | 747.0 | 1.0 | False | None | None | False | None | False | 747.0 | 0 |
3088382 | 106179 | None | code50 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 32 A | Each | 200.0 | 200.0 | 2.0 | False | None | None | False | None | False | 400.0 | 0 |
3088383 | 106179 | None | code51 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP | Each | 523.0 | 523.0 | 2.0 | False | None | None | False | None | False | 1046.0 | 0 |
3088384 | 106179 | None | code52 | Supplying and fixing regular MCB distribution boards on wall/wood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. II - Double Door 8 Way SP & N | Each | 1695.0 | 1695.0 | 2.0 | False | None | None | False | None | False | 3390.0 | 0 |
3088385 | 106179 | None | code53 | Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4 x 30 x 10 mm Aluminium Strips | Each | 3078.0 | 3078.0 | 2.0 | False | None | None | False | None | False | 6156.0 | 0 |
3088386 | 106179 | None | code54 | Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 A three phase 4 wire whole current class-1 Accuracy Energy Meter. | Each | 5125.0 | 5125.0 | 1.0 | False | None | None | False | None | False | 5125.0 | 0 |
3088387 | 106179 | None | code55 | Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. | Each | 3750.0 | 3750.0 | 1.0 | False | None | None | False | None | False | 3750.0 | 0 |
3088388 | 106179 | None | code56 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with
double ball bearing system. 48" Sweep (1200 mm) Regular model | Each | 2085.0 | 2085.0 | 12.0 | False | None | None | False | None | False | 25020.0 | 0 |
3088389 | 106179 | None | code57 | Supplying of .....feet -PVC Batten with integrated LED tube ....
W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI less than 80. Power Input: 220-240V@ 50/60Hz & Power factor less than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 W | Each | 740.0 | 740.0 | 16.0 | False | None | None | False | None | False | 11840.0 | 0 |
3088390 | 106179 | None | code58 | Supplying and fixing of 5'-80 W of T8 Fluorescent Tube with 54W power consumption with low 3mg Mercury content less phosphor coating Operating voltage range from 180V to 265V,
50Hz AC power Supply | Nos | 510.0 | 510.0 | 6.0 | False | None | None | False | None | False | 3060.0 | 0 |
3088391 | 106179 | None | code59 | Supplying of patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired with HF Electronic Ballast, Operating voltage range from 180V to 265V, 50Hz AC power supply excluding Tube. 1 x 4' Tube light fitting. | Each | 310.0 | 310.0 | 6.0 | False | None | None | False | None | False | 1860.0 | 0 |
3088392 | 106179 | None | code60 | Supplying & Fixing of 70-150 W lamp holder 2 Pin | Nos | 118.0 | 118.0 | 10.0 | False | None | None | False | None | False | 1180.0 | 0 |
3088393 | 106179 | None | code61 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. On wall/ ceiling / Rafter / Girders | Each | 119.0 | 119.0 | 22.0 | False | None | None | False | None | False | 2618.0 | 0 |
3088394 | 106179 | None | code62 | Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clA and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden
board and wired. | Each | 281.0 | 281.0 | 12.0 | False | None | None | False | None | False | 3372.0 | 0 |