tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1710501217000 | 0 | None | None | Buildings | Civil and other works | 996400546.08 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3090840 | 106300 | None | code01 | Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 16SWG(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sq CM | 0.56 | 0.56 | 60000.0 | False | None | None | False | None | False | 33600.0 | 0 | 3090841 | 106300 | None | code02 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Rmtr | 4.53 | 4.53 | 860.8 | False | None | None | False | None | False | 3899.424 | 0 | 3090842 | 106300 | None | code03 | Making 50 mm x 50 mm furrows, 25mm/ 50mm deep, 45 degrees to the center line of the road and at one metre interval in the existing thin bituminous wearing coarse including sweeping and disposal of excavated material.25 mm deep furrow cutting(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 10.38 | 10.38 | 4506.0 | False | None | None | False | None | False | 46772.28 | 0 | 3090843 | 106300 | None | code04 | Upto 8000.0 Sqm (2.0 Acres)---WORK TO BE UNDER TAKEN DURING MAINTENANCE:-Watering : The plants and lawns in the garden should be watered frequently as required looking to the climate, soil and plant conditions: If sprinklers are made available, it can be used other wise hose pipe can be used for watering, problems regarding pipe line damage during watering/maintenance should be repaired and taken care.
Weeding : Weeding has to be done regularly in the entire garden area including extra weed growth in the pathways and other remaining areas in the park. Weeding should be done regularly once in a fortnight and the weeds collected should be used for preparing manure or it should be disposed from the garden appropriately.
Sweeping : Sweeping of the garden area has to be done daily. The pathways, entire garden area should be swept and kept free of fallen leanves, branches, flowers, dust etc., and should be made use for the public. Dust bins in the garden area should be emptied and disposed properly and regularly. Any dead rodent, pets or animals are founds should be removed immediately and the garden spaces should be free from foul smell. Gazeboo, Chairs and Other Adomments should be cleaned daily.
Maintenance of Shrubs, Edges, Ground cover and other area by regular pruning, digging so as to maintain the garden aesthetically.Lawn moving shloud be done regularly every fortnight.Digging of soil around plants in the garden, should be carried out. Soil basins should be prepared around the hedges/ edges/ trees/ shrubs/ ground covers by digging the soil so as to maintain retention of water. This should be done before and after monsoon.
Pruning of plants in the garden, such as the Hedges, Trees, Shrubs, Ground cover plants, Topiary plants, Rose plants etc., should be carried out as and when required and as per the directions of officer in-charge of work.
Transportation of plastic and other materials should be removed from the garden, must be taken care. The swept leaf materials only should be used for preparation of compost manure in the garden itself and the compost manure should be used in the garden. All dead plants, branches and other waste matirials should be removed regularly and transported outside the garden. in the garden area dried leaves and other waste materials should be regularly removed from the garden at the risk of contractors.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 11.68 | 11.68 | 6069.0 | False | None | None | False | None | False | 70885.92 | 0 | 3090844 | 106300 | None | code05 | Providing & Fixing of corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Rmtr | 15.0 | 15.0 | 712.2 | False | None | None | False | None | False | 10683.0 | 0 | 3090845 | 106300 | None | code06 | Providing and applying tack coat with RS1 Bituminous Emulsion using emulsion pressure distributor at the rate of 0.20 Kg/Sqm on the prepared bituminous surface cleaned with mechanical broom(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 15.58 | 15.58 | 4506.0 | False | None | None | False | None | False | 70203.48 | 0 | 3090846 | 106300 | None | code07 | Supply of Fertiliser--Super Phosphate -50 gram, Neem oilcake -250gram, Bone meal-250gram, Potash-50gram,Furadan-25gram,Ammonium Sulphate-100gram,Chlorophyriphos-0.05 mili ltr.(Total 750 Gram) per Kg 22 rs/-(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 22.07 | 22.07 | 6559.0 | False | None | None | False | None | False | 144757.13 | 0 | 3090847 | 106300 | None | code08 | Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 33.75 | 33.75 | 1918.1 | False | None | None | False | None | False | 64735.875 | 0 | 3090848 | 106300 | None | code09 | Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Rmtr | 38.94 | 38.94 | 1233.6 | False | None | None | False | None | False | 48036.384 | 0 | 3090849 | 106300 | None | code10 | 2NDDIGGING:-Diggingofsoilbyremovinggrassetcifanyandlevellingofthesoiletc .. (1x1x0.45mt)(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 49.31 | 49.31 | 2951.55 | False | None | None | False | None | False | 145540.9305 | 0 | 3090850 | 106300 | None | code11 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Rmtr | 49.32 | 49.32 | 17594.3 | False | None | None | False | None | False | 867750.876 | 0 | 3090851 | 106300 | None | code12 | Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Job | 51.92 | 51.92 | 200.0 | False | None | None | False | None | False | 10384.0 | 0 | 3090852 | 106300 | None | code13 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Rmtr | 51.92 | 51.92 | 712.36 | False | None | None | False | None | False | 36985.7312 | 0 | 3090853 | 106300 | None | code14 | Providing and applying primer coat with SS1 grade Bitumen Emulsion on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70 Kg/Sqm using mechanical means.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 53.22 | 53.22 | 4506.0 | False | None | None | False | None | False | 239809.32 | 0 | 3090854 | 106300 | None | code15 | SCRAPPINGANDREMOVINGTOPSOIL:-Scrappingtheareabyremoving0.15msoilandremovingofunwantedplants,grassalongwithroots.25kminitialtransport,including lead, lift loading and unloading charges. (1x1x0.15mt)(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 55.45 | 55.45 | 983.85 | False | None | None | False | None | False | 54554.4825 | 0 | 3090855 | 106300 | None | code16 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 64.9 | 64.9 | 443.82 | False | None | None | False | None | False | 28803.918 | 0 | 3090856 | 106300 | None | code17 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Rmtr | 67.5 | 67.5 | 3818.8 | False | None | None | False | None | False | 257769.0 | 0 | 3090857 | 106300 | None | code18 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 68.79 | 68.79 | 895.1 | False | None | None | False | None | False | 61573.929 | 0 | 3090858 | 106300 | None | code19 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material to the appropriate disposal area as per direction of Engineer-in-charge. 100 mm dia pipe(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | m | 68.79 | 68.79 | 350.0 | False | None | None | False | None | False | 24076.5 | 0 | 3090859 | 106300 | None | code20 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Nos | 77.88 | 77.88 | 696.0 | False | None | None | False | None | False | 54204.48 | 0 | 3090860 | 106300 | None | code21 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 84.37 | 84.37 | 135.0 | False | None | None | False | None | False | 11389.95 | 0 | 3090861 | 106300 | None | code22 | Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. BASEMENT FLOOR (Qty as per drip moulding)(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Rmtr | 86.14 | 86.14 | 1252.8 | False | None | None | False | None | False | 107916.192 | 0 | 3090862 | 106300 | None | code23 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | No | 90.86 | 90.86 | 412.0 | False | None | None | False | None | False | 37434.32 | 0 | 3090863 | 106300 | None | code24 | procurement of quality red earth/soil and heap around pit (1x1x0.15mt)(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 93.96 | 93.96 | 983.85 | False | None | None | False | None | False | 92442.546 | 0 | 3090864 | 106300 | None | code25 | 1STDIGGING:-Diggingoftheareafordevelopinglawnincludingremovingweeds,debris if any and breaking of clumps, watering etc. (1x1x0.45mt)(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 98.62 | 98.62 | 2951.55 | False | None | None | False | None | False | 291081.861 | 0 | 3090865 | 106300 | None | code26 | Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 110.33 | 110.33 | 450.6 | False | None | None | False | None | False | 49714.698 | 0 | 3090866 | 106300 | None | code27 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 Kg/10 Sqm) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 115.52 | 115.52 | 1918.91 | False | None | None | False | None | False | 221672.4832 | 0 | 3090867 | 106300 | None | code28 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking to the appropriate disposal area as per direction of Engineer-in-charge.Of area 3 Sqm and below(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 122.01 | 122.01 | 480.0 | False | None | None | False | None | False | 58564.8 | 0 | 3090868 | 106300 | None | code29 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 123.31 | 123.31 | 4964.55 | False | None | None | False | None | False | 612178.6605 | 0 | 3090869 | 106300 | None | code30 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 123.31 | 123.31 | 164.86 | False | None | None | False | None | False | 20328.8866 | 0 | 3090870 | 106300 | None | code31 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | No | 129.8 | 129.8 | 116.0 | False | None | None | False | None | False | 15056.8 | 0 | 3090871 | 106300 | None | code32 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 129.8 | 129.8 | 23398.67 | False | None | None | False | None | False | 3037147.366 | 0 | 3090872 | 106300 | None | code33 | Procurement of quality lawn grass Bermuda Grass(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 129.8 | 129.8 | 1280.0 | False | None | None | False | None | False | 166144.0 | 0 | 3090873 | 106300 | None | code34 | Procurement of quality lawn grass Ooty kiku Grass(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 129.8 | 129.8 | 1050.0 | False | None | None | False | None | False | 136290.0 | 0 | 3090874 | 106300 | None | code35 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 132.4 | 132.4 | 18400.26 | False | None | None | False | None | False | 2436194.424 | 0 | 3090875 | 106300 | None | code36 | Compacting original ground supporting embankment-Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 136.29 | 136.29 | 836.4 | False | None | None | False | None | False | 113992.956 | 0 | 3090876 | 106300 | None | code37 | Supplyofinputssuchassand,FYM,Redearthin1:3:6ratio.mixingandspreadingthe mixture to 7.50cm thickness wherever required.* Red soil-0.0075cum, *Farm Yard manure-0.0225cum, * Sand-0.045cum(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 141.35 | 141.35 | 491.93 | False | None | None | False | None | False | 69534.3055 | 0 | 3090877 | 106300 | None | code38 | Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 141.48 | 141.48 | 1051.4 | False | None | None | False | None | False | 148752.072 | 0 | 3090878 | 106300 | None | code39 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 149.27 | 149.27 | 475.02 | False | None | None | False | None | False | 70906.2354 | 0 | 3090879 | 106300 | None | code40 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 153.16 | 153.16 | 4339.2 | False | None | None | False | None | False | 664591.872 | 0 | 3090880 | 106300 | None | code41 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 164.85 | 164.85 | 23398.66 | False | None | None | False | None | False | 3857269.101 | 0 | 3090881 | 106300 | None | code42 | Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 175.23 | 175.23 | 19424.35 | False | None | None | False | None | False | 3403728.8505 | 0 | 3090882 | 106300 | None | code43 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Kg | 176.53 | 176.53 | 10041.6 | False | None | None | False | None | False | 1772643.648 | 0 | 3090883 | 106300 | None | code44 | Procurement of quality lawn grass Phasphalam Grass(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 194.7 | 194.7 | 1050.0 | False | None | None | False | None | False | 204435.0 | 0 | 3090884 | 106300 | None | code45 | Providing and fixing MS casing collars per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thic ness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Nos | 194.7 | 194.7 | 2.0 | False | None | None | False | None | False | 389.4 | 0 | 3090885 | 106300 | None | code46 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | No | 194.7 | 194.7 | 216.0 | False | None | None | False | None | False | 42055.2 | 0 | 3090886 | 106300 | None | code47 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 Sqm. Over and including priming coat of exterior primer applied @ 0.90 L/10 Sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 202.49 | 202.49 | 4100.79 | False | None | None | False | None | False | 830368.9671 | 0 | 3090887 | 106300 | None | code48 | Providing and laying at site of wor MS asing caps as per IS 1239 (part- II) 1982 with all latest amendm nts if any for any dia. The thickness of plate used for covering one e shall be 3mm (minimum). The dimensions of caps and olars shall be strictly as per IS 1239 (Part-II) 1982 with all mendments including cost of material and labour charges for fixing, if a y etc. complete with all lead and lifts and as directed by the Engineer in charge.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Nos | 212.87 | 212.87 | 2.0 | False | None | None | False | None | False | 425.74 | 0 | 3090888 | 106300 | None | code49 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.3C x 4 mm2(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | m | 218.06 | 218.06 | 550.0 | False | None | None | False | None | False | 119933.0 | 0 | 3090889 | 106300 | None | code50 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Kg | 218.06 | 218.06 | 8866.71 | False | None | None | False | None | False | 1933474.7826 | 0 | 3090890 | 106300 | None | code51 | Procurement of quality lawn grass Mexican Grass(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 259.6 | 259.6 | 1280.0 | False | None | None | False | None | False | 332288.0 | 0 | 3090891 | 106300 | None | code52 | Procurement of quality lawn grass Korean Grass(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 259.6 | 259.6 | 1050.0 | False | None | None | False | None | False | 272580.0 | 0 | 3090892 | 106300 | None | code53 | Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete)(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Nos | 272.58 | 272.58 | 2.0 | False | None | None | False | None | False | 545.16 | 0 | 3090893 | 106300 | None | code54 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 273.88 | 273.88 | 11602.71 | False | None | None | False | None | False | 3177750.2148 | 0 | 3090894 | 106300 | None | code55 | Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 283.2 | 283.2 | 410.0 | False | None | None | False | None | False | 116112.0 | 0 | 3090895 | 106300 | None | code56 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 314.12 | 314.12 | 898.53 | False | None | None | False | None | False | 282246.2436 | 0 | 3090896 | 106300 | None | code57 | Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra)600 x 200 x 100 mm Kerb Stone(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | m | 324.5 | 324.5 | 1502.0 | False | None | None | False | None | False | 487399.0 | 0 | 3090897 | 106300 | None | code58 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 336.18 | 336.18 | 33.93 | False | None | None | False | None | False | 11406.5874 | 0 | 3090898 | 106300 | None | code59 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 345.27 | 345.27 | 10540.74 | False | None | None | False | None | False | 3639401.2998 | 0 | 3090899 | 106300 | None | code60 | Fixing of ..... A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling..15A to 63A TPST(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Each | 360.84 | 360.84 | 2.0 | False | None | None | False | None | False | 721.68 | 0 | 3090900 | 106300 | None | code61 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 382.91 | 382.91 | 3327.03 | False | None | None | False | None | False | 1273953.0573 | 0 | 3090901 | 106300 | None | code62 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside)(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 404.98 | 404.98 | 11795.95 | False | None | None | False | None | False | 4777123.831 | 0 | 3090902 | 106300 | None | code63 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws.20 x 20 x 2.5(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Each | 423.32 | 423.32 | 2.0 | False | None | None | False | None | False | 846.64 | 0 | 3090903 | 106300 | None | code64 | Planting of trees Digging pits of size 0.75 x 0.75x 0.75m, filling 50% of the pit with top soil and remaining 50% of pit with 1:2:3 proportion ofsand (0.035cum) FYM (0.070cum) Red earth (0.105 cum) and planting of well grown tree saplings (excluding cost of plants)(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | No | 428.34 | 428.34 | 620.0 | False | None | None | False | None | False | 265570.8 | 0 | 3090904 | 106300 | None | code65 | Removal of telephone / Electric poles including excavation and dismantling of foundation concrete and lines under the supervision of concerned department, disposal with all lifts and lead and stacking the serviceable and unserviceable material separately(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Nos | 440.02 | 440.02 | 30.0 | False | None | None | False | None | False | 13200.6 | 0 | 3090905 | 106300 | None | code66 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside)(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 453.0 | 453.0 | 4100.79 | False | None | None | False | None | False | 1857657.87 | 0 | 3090906 | 106300 | None | code67 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 459.49 | 459.49 | 416.8 | False | None | None | False | None | False | 191515.432 | 0 | 3090907 | 106300 | None | code68 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 471.17 | 471.17 | 4079.87 | False | None | None | False | None | False | 1922312.3479 | 0 | 3090908 | 106300 | None | code69 | Construction of Median and Island above road level with approved material deposited at site from roadway cutting and excavation for drain and foundation of other structures, spread, graded and compacted as per clause 408(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 476.37 | 476.37 | 202.77 | False | None | None | False | None | False | 96593.5449 | 0 | 3090909 | 106300 | None | code70 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)Borewell depth of 0 to 50 Mtr(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Rmtr | 480.26 | 480.26 | 100.0 | False | None | None | False | None | False | 48026.0 | 0 | 3090910 | 106300 | None | code71 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 481.56 | 481.56 | 2184.86 | False | None | None | False | None | False | 1052141.1816 | 0 | 3090911 | 106300 | None | code72 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | No | 486.75 | 486.75 | 116.0 | False | None | None | False | None | False | 56463.0 | 0 | 3090912 | 106300 | None | code73 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer In area of light jungle(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 510.11 | 510.11 | 152.61 | False | None | None | False | None | False | 77847.8871 | 0 | 3090913 | 106300 | None | code74 | Providing and supplying aluminium extruded tubular and other alu- minium sections as per the architectural drawings and approved draw- ings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Kg | 528.29 | 528.29 | 9258.6 | False | None | None | False | None | False | 4891225.794 | 0 | 3090914 | 106300 | None | code75 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 Kg/sqcm & class 3(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | m | 533.48 | 533.48 | 108.0 | False | None | None | False | None | False | 57615.84 | 0 | 3090915 | 106300 | None | code76 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A SP (BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Each | 538.67 | 538.67 | 2.0 | False | None | None | False | None | False | 1077.34 | 0 | 3090916 | 106300 | None | code77 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Depth exceeding 1.5 m, but not exceeding 3 m(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 551.65 | 551.65 | 484.49 | False | None | None | False | None | False | 267268.9085 | 0 | 3090917 | 106300 | None | code78 | Providing and laying Cement concrete flooring 40 mm thick with 20 mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 585.4 | 585.4 | 1283.4 | False | None | None | False | None | False | 751302.36 | 0 | 3090918 | 106300 | None | code79 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in- charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials, labour, usage charges of machinery complete as per specifications.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Kg | 586.7 | 586.7 | 1080.0 | False | None | None | False | None | False | 633636.0 | 0 | 3090919 | 106300 | None | code80 | Supply of Palm trees/accent trees such as-Areca Leutescens 1.5 Mtr ht(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | No | 590.0 | 590.0 | 50.0 | False | None | None | False | None | False | 29500.0 | 0 | 3090920 | 106300 | None | code81 | Borewell depth of 50 to 100 Mtr(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Rmtr | 602.27 | 602.27 | 100.0 | False | None | None | False | None | False | 60227.0 | 0 | 3090921 | 106300 | None | code82 | Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 615.25 | 615.25 | 18002.07 | False | None | None | False | None | False | 11075773.5675 | 0 | 3090922 | 106300 | None | code83 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motor.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Kvar | 623.04 | 623.04 | 2.0 | False | None | None | False | None | False | 1246.08 | 0 | 3090923 | 106300 | None | code84 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 625.64 | 625.64 | 2306.9 | False | None | None | False | None | False | 1443288.916 | 0 | 3090924 | 106300 | None | code85 | Labour Charges mixingInputsasperprescribedproportionandquantityandspreading,applyingfertilizers,digging,levelling,anddibblingwithlawngrassataspacingof5cmx5cm& as per the direction of the Officer in charge of the work.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 629.53 | 629.53 | 1280.0 | False | None | None | False | None | False | 805798.4 | 0 | 3090925 | 106300 | None | code86 | Borewell depth of 100 to 150 Mtr(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Rmtr | 639.91 | 639.91 | 100.0 | False | None | None | False | None | False | 63991.0 | 0 | 3090926 | 106300 | None | code87 | Labour Charges mixingInputsasperprescribedproportionandquantityandspreading,applyingfertilizers,digging,levelling,anddibblingwithlawngrassataspacingof5cmx5cm& as per the direction of the Officer in charge of the work.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 649.0 | 649.0 | 1050.0 | False | None | None | False | None | False | 681450.0 | 0 | 3090927 | 106300 | None | code88 | Supply of Palm trees/accent trees such as-Polyatia Ashoka 1.5 Mtr(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | No | 708.0 | 708.0 | 50.0 | False | None | None | False | None | False | 35400.0 | 0 | 3090928 | 106300 | None | code89 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | No | 713.9 | 713.9 | 8.0 | False | None | None | False | None | False | 5711.2 | 0 | 3090929 | 106300 | None | code90 | Labour Charges mixingInputsasperprescribedproportionandquantityandspreading,applyingfertilizers,digging,levelling,anddibblingwithlawngrassataspacingof5cmx5cm& as per the direction of the Officer in charge of the work.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 713.9 | 713.9 | 1050.0 | False | None | None | False | None | False | 749595.0 | 0 | 3090930 | 106300 | None | code91 | Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Rmtr | 713.9 | 713.9 | 400.0 | False | None | None | False | None | False | 285560.0 | 0 | 3090931 | 106300 | None | code92 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Handles 300mm(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | No | 713.9 | 713.9 | 224.0 | False | None | None | False | None | False | 159913.6 | 0 | 3090932 | 106300 | None | code93 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Kg | 733.37 | 733.37 | 4407.06 | False | None | None | False | None | False | 3232005.5922 | 0 | 3090933 | 106300 | None | code94 | Borewell depth of 150 to 200 Mtr(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Rmtr | 742.46 | 742.46 | 100.0 | False | None | None | False | None | False | 74246.0 | 0 | 3090934 | 106300 | None | code95 | Labour Charges mixing Input sas perprescribe dproportion and quantity and spreading, applying fertilizers, digging, levelling, and dibbling with lawn grassata spacing of5cmx5cm & as per the direction of the Officer in charge of the work. (BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 759.33 | 759.33 | 2330.0 | False | None | None | False | None | False | 1769238.9 | 0 | 3090935 | 106300 | None | code96 | Supply of decorative Trees such as Pongamia, Ceasalpinia, Lagerstromia, Bauhunia, Golden melauluca, Tabebuia Rosea, Jacaranda etc (BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | No | 767.0 | 767.0 | 150.0 | False | None | None | False | None | False | 115050.0 | 0 | 3090936 | 106300 | None | code97 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 Kg/bag of cement. (For calculation purpose 320 Kg of Cement for M-20 grade of Concrete is considered in the analysis)(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 798.27 | 798.27 | 653.37 | False | None | None | False | None | False | 521565.6699 | 0 | 3090937 | 106300 | None | code98 | Borewell depth of 200 to 250 Mtr(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Rmtr | 870.96 | 870.96 | 100.0 | False | None | None | False | None | False | 87096.0 | 0 | 3090938 | 106300 | None | code99 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.
3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.)(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 878.75 | 878.75 | 895.11 | False | None | None | False | None | False | 786577.9125 | 0 | 3090939 | 106300 | None | code100 | Supply of Palm trees/accent trees such as-Ficus Blakeana/Benjamina 1.0 Mtr(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | No | 885.0 | 885.0 | 50.0 | False | None | None | False | None | False | 44250.0 | 0 | 3090940 | 106300 | None | code101 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 Kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately)Size 62 x 100mm(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | m | 911.2 | 911.2 | 373.8 | False | None | None | False | None | False | 340606.56 | 0 | 3090941 | 106300 | None | code102 | Borewell depth of 250 to 300 Mtr(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Rmtr | 960.52 | 960.52 | 100.0 | False | None | None | False | None | False | 96052.0 | 0 | 3090942 | 106300 | None | code103 | Dismantling of cement concrete platform along with curtain walls and base concrete etc. including stacking of useful materials near the site and disposal of unserviceable materials to the appropriate disposal area as per direction of Engineer-in-charge. 120 x 120 cm (outside to outside)(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 981.29 | 981.29 | 442.58 | False | None | None | False | None | False | 434299.3282 | 0 | 3090943 | 106300 | None | code104 | Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 1038.4 | 1038.4 | 535.0 | False | None | None | False | None | False | 555544.0 | 0 | 3090944 | 106300 | None | code105 | Supply of Palm trees/accent trees such as-Raphis Excelsa 0.9 Mtr (BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | No | 1121.0 | 1121.0 | 50.0 | False | None | None | False | None | False | 56050.0 | 0 | 3090945 | 106300 | None | code106 | Borewell depth of 300 to 350 Mtr(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Rmtr | 1126.66 | 1126.66 | 100.0 | False | None | None | False | None | False | 112666.0 | 0 | 3090946 | 106300 | None | code107 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 Kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 1153.92 | 1153.92 | 296.11 | False | None | None | False | None | False | 341687.2512 | 0 | 3090947 | 106300 | None | code108 | Providing and laying 100mm thick pre-cast cover slabs over drains & Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00 Kg/Sqm, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 1204.54 | 1204.54 | 1284.3 | False | None | None | False | None | False | 1546990.722 | 0 | 3090948 | 106300 | None | code109 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10Kg/ Sqm) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 1282.42 | 1282.42 | 108.0 | False | None | None | False | None | False | 138501.36 | 0 | 3090949 | 106300 | None | code110 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 1300.6 | 1300.6 | 5.66 | False | None | None | False | None | False | 7361.396 | 0 | 3090950 | 106300 | None | code111 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Nos | 1318.77 | 1318.77 | 116.0 | False | None | None | False | None | False | 152977.32 | 0 | 3090951 | 106300 | None | code112 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | No | 1365.5 | 1365.5 | 116.0 | False | None | None | False | None | False | 158398.0 | 0 | 3090952 | 106300 | None | code113 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800Kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 1432.99 | 1432.99 | 669.6 | False | None | None | False | None | False | 959530.104 | 0 | 3090953 | 106300 | None | code114 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 Kg and door width upto 700 mm), with necessary accessories and screws etc. complete.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | No | 1445.97 | 1445.97 | 175.0 | False | None | None | False | None | False | 253044.75 | 0 | 3090954 | 106300 | None | code115 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional
T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Each | 1457.65 | 1457.65 | 140.0 | False | None | None | False | None | False | 204071.0 | 0 | 3090955 | 106300 | None | code116 | Providing and laying 80mm thick factory made precast M -30 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Commercial Traffic Axle load repetitions upto 10MSA & for Residential Streets of approved shape and colour, laid in required pattern and including over 40mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (WMM/WBM Base to be paid separately as per relevant technical specification)(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 1506.98 | 1506.98 | 606.0 | False | None | None | False | None | False | 913229.88 | 0 | 3090956 | 106300 | None | code117 | Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6Kg/Sqm, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 1518.66 | 1518.66 | 20.0 | False | None | None | False | None | False | 30373.2 | 0 | 3090957 | 106300 | None | code118 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 Kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 1525.15 | 1525.15 | 4610.45 | False | None | None | False | None | False | 7031627.8175 | 0 | 3090958 | 106300 | None | code119 | Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 1539.43 | 1539.43 | 2.83 | False | None | None | False | None | False | 4356.5869 | 0 | 3090959 | 106300 | None | code120 | Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge (Dash fastener to bepaid for separately).(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | m | 1541.11 | 1541.11 | 1238.4 | False | None | None | False | None | False | 1908510.624 | 0 | 3090960 | 106300 | None | code121 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 1547.22 | 1547.22 | 2.83 | False | None | None | False | None | False | 4378.6326 | 0 | 3090961 | 106300 | None | code122 | Roof Water Proofing. Surface Preparation: remove all surface laitance and contamination free from loose aggregate or other sharp protrusions with fairly smooth finish by wire brush and grinding method and surface shall be DRY for application of single component pitch modified polyurethane cures by reaction with atmospheric moisture to given a tough elastomeric waterproof membrane.
System : Provide and applying 1.2 mm thick roller applied single component bitumen modified polyurathene coating NITPROOF 600 or equivalent, having elongation capacity of 450 % as per ASTM D412, having Tensile strength 1.5 n/mm2 as per ASTM D 412, Tear resistance of 15 N as per ASTM D 624 and having shore A Hardness 50 as per ASTM D 2240. Waterproofing treatment to be provided after proper surface preparation as per Manufacture Specification.
Protection of waterproofing system with minimum 50 mm thick screed and providing construction joints and sealing the same with PU sealant.GROUND FLOOR
(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 1593.0 | 1593.0 | 1035.3 | False | None | None | False | None | False | 1649232.9 | 0 | 3090962 | 106300 | None | code123 | Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 1606.92 | 1606.92 | 80.2 | False | None | None | False | None | False | 128874.984 | 0 | 3090963 | 106300 | None | code124 | Providing and fixing in position 12mm thick plaster of paris (Gypsum anhydrous) for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 1653.65 | 1653.65 | 1740.6 | False | None | None | False | None | False | 2878343.19 | 0 | 3090964 | 106300 | None | code125 | Providing and fixing Green 50 Liter Industrial Dustbin, Size: L 42 X W 47 X H 65 Cm of approved make including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. (BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | No | 1681.5 | 1681.5 | 38.0 | False | None | None | False | None | False | 63897.0 | 0 | 3090965 | 106300 | None | code126 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800Kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 1700.38 | 1700.38 | 9066.24 | False | None | None | False | None | False | 15416053.1712 | 0 | 3090966 | 106300 | None | code127 | Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 1721.15 | 1721.15 | 1710.66 | False | None | None | False | None | False | 2944302.459 | 0 | 3090967 | 106300 | None | code128 | Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 1738.02 | 1738.02 | 2.83 | False | None | None | False | None | False | 4918.5966 | 0 | 3090968 | 106300 | None | code129 | Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Job | 1752.3 | 1752.3 | 2.0 | False | None | None | False | None | False | 3504.6 | 0 | 3090969 | 106300 | None | code130 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 1880.8 | 1880.8 | 1142.64 | False | None | None | False | None | False | 2149077.312 | 0 | 3090970 | 106300 | None | code131 | Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Set | 2011.9 | 2011.9 | 2.0 | False | None | None | False | None | False | 4023.8 | 0 | 3090971 | 106300 | None | code132 | UGT/OHT (inside) waterproofing with Anti-microbial Coating Providing and Applying two component, water-based food grade epoxy resin coating on inside surface of Potable water tank having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 300 of US FDA, having mixing Ratio (Base: Hardener: Water) 1:1:1 to be applied @ 0.35 Kg/Sqm in 2 coats. Ensure that this coating is applied over the protective plaster, and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 2171.55 | 2171.55 | 2261.0 | False | None | None | False | None | False | 4909874.55 | 0 | 3090972 | 106300 | None | code133 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer- in-charge. In cement mortar(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 2185.83 | 2185.83 | 2699.23 | False | None | None | False | None | False | 5900057.9109 | 0 | 3090973 | 106300 | None | code134 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per m2 including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 2197.51 | 2197.51 | 2610.9 | False | None | None | False | None | False | 5737478.859 | 0 | 3090974 | 106300 | None | code135 | Supply of Palm trees/accent trees such as-Wodyetia Bifurcata 2.5 Mtr ht(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | No | 2360.0 | 2360.0 | 120.0 | False | None | None | False | None | False | 283200.0 | 0 | 3090975 | 106300 | None | code136 | Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 nd latest ammendments, electrical resistance welded steel tubes, terial and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixe with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10Kg/m.prices include Collar-Medium duty.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | m | 2509.03 | 2509.03 | 70.0 | False | None | None | False | None | False | 175632.1 | 0 | 3090976 | 106300 | None | code137 | Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38Kgs (weight of cover 23 Kgs and weight of frame 15 Kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Nos | 2546.68 | 2546.68 | 24.0 | False | None | None | False | None | False | 61120.32 | 0 | 3090977 | 106300 | None | code138 | Providing and fixing aluminium coated and polyester based netted curtains complete. The work includes cost of all materials, labour charges, lead and lift, etc., complete.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Rmtr | 2596.0 | 2596.0 | 440.0 | False | None | None | False | None | False | 1142240.0 | 0 | 3090978 | 106300 | None | code139 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 2618.07 | 2618.07 | 53.51 | False | None | None | False | None | False | 140092.9257 | 0 | 3090979 | 106300 | None | code140 | Supply of Palm trees/accent trees such as-Plumeria Alba 1.8 Mtr(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | No | 2950.0 | 2950.0 | 100.0 | False | None | None | False | None | False | 295000.0 | 0 | 3090980 | 106300 | None | code141 | Supply of Palm trees/accent trees such as-Topiary Ficus trees 1.0 Mtr bushy(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | No | 2950.0 | 2950.0 | 50.0 | False | None | None | False | None | False | 147500.0 | 0 | 3090981 | 106300 | None | code142 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. (BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 3107.41 | 3107.41 | 496.5 | False | None | None | False | None | False | 1542829.065 | 0 | 3090982 | 106300 | None | code143 | Demolishing R.C.C. work manually/ by mechanical means including stack- ing of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 3148.95 | 3148.95 | 3117.1 | False | None | None | False | None | False | 9815592.045 | 0 | 3090983 | 106300 | None | code144 | Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 .For Grading -V Material(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 3228.13 | 3228.13 | 450.6 | False | None | None | False | None | False | 1454595.378 | 0 | 3090984 | 106300 | None | code145 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface andcompactingwithvibratoryrollertoachievethedesireddensity. (BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 3321.58 | 3321.58 | 45.0 | False | None | None | False | None | False | 149471.1 | 0 | 3090985 | 106300 | None | code146 | Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 3351.44 | 3351.44 | 677.28 | False | None | None | False | None | False | 2269863.2832 | 0 | 3090986 | 106300 | None | code147 | Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:(a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sbimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.(c)Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved s etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge.Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the cur- tain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in m2 . up to two decimal places.Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 m2 from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science
& Technologies, India. Cost of testing is payable separately.The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or by any other accreditation body which operates in accordance with ISO / IEC 17011 and accredits labs as per ISO/ IEC 17025.1. Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa)
& (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr. 2. Static Water Penetration Test. (50pa to 1500p) as per ASTME- 331-09 testing method for a range up to 2000 ml.3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml4. Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm,..5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test, Tests to be conducted on site.6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 3485.13 | 3485.13 | 36.0 | False | None | None | False | None | False | 125464.68 | 0 | 3090987 | 106300 | None | code148 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2)For payment, only the actual area of glass on face 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/ m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 3949.81 | 3949.81 | 1050.0 | False | None | None | False | None | False | 4147300.5 | 0 | 3090988 | 106300 | None | code149 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-do- 35 mm thick both side Commercial(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 4311.96 | 4311.96 | 366.48 | False | None | None | False | None | False | 1580247.1008 | 0 | 3090989 | 106300 | None | code150 | Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1101.6.600mm dia(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Rmtr | 4328.83 | 4328.83 | 60.0 | False | None | None | False | None | False | 259729.8 | 0 | 3090990 | 106300 | None | code151 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 Kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 4523.53 | 4523.53 | 117.99 | False | None | None | False | None | False | 533731.3047 | 0 | 3090991 | 106300 | None | code152 | Providing and fixing of expansion joint system related with wall joint (internal/external) location as per drawings and direction of Engineer-In Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063) Wall Joint of 100 mm gap(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | m | 4835.5 | 4835.5 | 220.0 | False | None | None | False | None | False | 1063810.0 | 0 | 3090992 | 106300 | None | code153 | Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resist- ance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sand- wiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete For Straight Portion(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 5177.72 | 5177.72 | 1996.0 | False | None | None | False | None | False | 10334729.12 | 0 | 3090993 | 106300 | None | code154 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 5199.79 | 5199.79 | 315.81 | False | None | None | False | None | False | 1642145.6799 | 0 | 3090994 | 106300 | None | code155 | Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 5397.08 | 5397.08 | 405.6 | False | None | None | False | None | False | 2189055.648 | 0 | 3090995 | 106300 | None | code156 | Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates asper ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed toaccommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint
System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063). Roof Joint of 100 mm gap(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | m | 5424.2 | 5424.2 | 346.0 | False | None | None | False | None | False | 1876773.2 | 0 | 3090996 | 106300 | None | code157 | Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universalaluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer in Charge. (Material shall confirm to ASTM 6063). Floor Joint of 100 mm gap(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | m | 5800.15 | 5800.15 | 220.0 | False | None | None | False | None | False | 1276033.0 | 0 | 3090997 | 106300 | None | code158 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 5812.44 | 5812.44 | 38.4 | False | None | None | False | None | False | 223197.696 | 0 | 3090998 | 106300 | None | code159 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc. to be paid separately) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 6129.16 | 6129.16 | 24.0 | False | None | None | False | None | False | 147099.84 | 0 | 3090999 | 106300 | None | code160 | Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-in-charge (panneling to be paid for separately).(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 6790.22 | 6790.22 | 392.76 | False | None | None | False | None | False | 2666926.8072 | 0 | 3091000 | 106300 | None | code161 | Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indic ting the location of the site, recommended depth of casing pipe required seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casin pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging techn al personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above M and upto 30 M - 15%,
b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of R . 100/- is to be deducted for Dry Borewell towards yield test. tc. complete.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Each | 6863.82 | 6863.82 | 2.0 | False | None | None | False | None | False | 13727.64 | 0 | 3091001 | 106300 | None | code162 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 6915.74 | 6915.74 | 1278.0 | False | None | None | False | None | False | 8838315.72 | 0 | 3091002 | 106300 | None | code163 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 7423.26 | 7423.26 | 80.07 | False | None | None | False | None | False | 594380.4282 | 0 | 3091003 | 106300 | None | code164 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates. Including FormWork(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 7773.72 | 7773.72 | 1324.22 | False | None | None | False | None | False | 10294115.4984 | 0 | 3091004 | 106300 | None | code165 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 8292.92 | 8292.92 | 83.62 | False | None | None | False | None | False | 693453.9704 | 0 | 3091005 | 106300 | None | code166 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Job | 8437.0 | 8437.0 | 2.0 | False | None | None | False | None | False | 16874.0 | 0 | 3091006 | 106300 | None | code167 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.CULVERT/DRAIN BASE SLAB(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 8461.01 | 8461.01 | 8.4 | False | None | None | False | None | False | 71072.484 | 0 | 3091007 | 106300 | None | code168 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including FormWork.GRADE SLAB(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 8470.85 | 8470.85 | 493.65 | False | None | None | False | None | False | 4181635.1025 | 0 | 3091008 | 106300 | None | code169 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall
be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 8740.73 | 8740.73 | 342.15 | False | None | None | False | None | False | 2990640.7695 | 0 | 3091009 | 106300 | None | code170 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including FormWork.Security CabinFOOTINGS(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 8813.37 | 8813.37 | 9.85 | False | None | None | False | None | False | 86811.6945 | 0 | 3091010 | 106300 | None | code171 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.CULVERT DECK SLAB(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 8826.66 | 8826.66 | 11.77 | False | None | None | False | None | False | 103889.7882 | 0 | 3091011 | 106300 | None | code172 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.DRAIN BASE SLAB(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 8863.91 | 8863.91 | 128.43 | False | None | None | False | None | False | 1138391.9613 | 0 | 3091012 | 106300 | None | code173 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including FormWork. FOOTINGS(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 8882.06 | 8882.06 | 3005.49 | False | None | None | False | None | False | 26694942.5094 | 0 | 3091013 | 106300 | None | code174 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including FormWork.Security Cabin, Pedestal(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 8976.58 | 8976.58 | 5.42 | False | None | None | False | None | False | 48653.0636 | 0 | 3091014 | 106300 | None | code175 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including FormWork. PEDESTALS(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 9046.54 | 9046.54 | 79.73 | False | None | None | False | None | False | 721280.6342 | 0 | 3091015 | 106300 | None | code176 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.RAFT(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 9148.68 | 9148.68 | 102.61 | False | None | None | False | None | False | 938746.0548 | 0 | 3091016 | 106300 | None | code177 | Providing & fixing in position Outdoor WPC Wall Cladding at all height with planks of sizes 26mm thick, 610mm minimum length and 305 mm nminimum width each work made out of Eco friendly or equivalent brand with necessary profiled edges; placed on walls. WPC panels and frame all held in place as per manufacturers design details and finished to smooth as complete wall cladding as per direction of Engineer in-charge.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Sqm | 9392.8 | 9392.8 | 712.0 | False | None | None | False | None | False | 6687673.6 | 0 | 3091017 | 106300 | None | code178 | Providing and laying Bituminous Macadam with 120 TPH capacity hot mix plant batch type using crushed aggregates of specified grading premixed with bituminous binder VG- 40 @ 3.3% by weight of mix, transported to site, laid over a previously prepared surface with mechanical paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 10069.88 | 10069.88 | 587.95 | False | None | None | False | None | False | 5920585.946 | 0 | 3091018 | 106300 | None | code179 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.DRAIN SIDE WALL(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 11617.75 | 11617.75 | 171.24 | False | None | None | False | None | False | 1989423.51 | 0 | 3091019 | 106300 | None | code180 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protectionsuitable for thepumpdescribedabove 1 no Indoor type NOTE: 1) DOL- Direct Online Starter
2) S-D- Star Delta Starter etc. complete.3 to 6 HP pumps(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Each | 12395.9 | 12395.9 | 2.0 | False | None | None | False | None | False | 24791.8 | 0 | 3091020 | 106300 | None | code181 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.CILL/CHEJJA(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 12478.32 | 12478.32 | 60.62 | False | None | None | False | None | False | 756435.7584 | 0 | 3091021 | 106300 | None | code182 | Providing and laying Semi Dense Bituminous Concrete with 40/60 TPH capacity hot mix plant batch type using crushed aggregates of specified grading premixed with bituminous binder VG-30 @ 5% by weight of mix and filler, transported to site, laid over a previously prepared surface with mechanical paver finisher to the required grade, level and alignment and rolled as per MoRTH V revision.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 13177.3 | 13177.3 | 232.65 | False | None | None | False | None | False | 3065698.845 | 0 | 3091022 | 106300 | None | code183 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.PLINTHBEAM,ROOF SLAB,STAIRCASE(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 13323.32 | 13323.32 | 1534.72 | False | None | None | False | None | False | 20447565.6704 | 0 | 3091023 | 106300 | None | code184 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. ROOF BEAM,LINTEL(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 14211.54 | 14211.54 | 732.77 | False | None | None | False | None | False | 10413790.1658 | 0 | 3091024 | 106300 | None | code185 | Providing Brick work with common burnt clay machine moulded perforated bricks of class designation 5.0 conforming to IS: 2222 in superstructure above plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) With Non modular bricks including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 14248.15 | 14248.15 | 172.22 | False | None | None | False | None | False | 2453816.393 | 0 | 3091025 | 106300 | None | code186 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.CULVERT/DRAIN SIDE WALL(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 14258.15 | 14258.15 | 25.2 | False | None | None | False | None | False | 359305.38 | 0 | 3091026 | 106300 | None | code187 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. COLUMN,LIFT CORE WALL,SUMP WALL(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 15099.76 | 15099.76 | 1402.75 | False | None | None | False | None | False | 21181188.34 | 0 | 3091027 | 106300 | None | code188 | Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 600mmx600mmx170mm.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Each | 18846.96 | 18846.96 | 2.0 | False | None | None | False | None | False | 37693.92 | 0 | 3091028 | 106300 | None | code189 | Providing and fixing Outdoor Stone Garden Bench BENCHES (5'*2') of approved make including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. (BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | No | 37170.0 | 37170.0 | 17.0 | False | None | None | False | None | False | 631890.0 | 0 | 3091029 | 106300 | None | code190 | Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For HP etc Complete.5.00 HP - 90 LPM @ 110 m = 15 STG Outlet Dia - 2.00 (BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Each | 41713.83 | 41713.83 | 2.0 | False | None | None | False | None | False | 83427.66 | 0 | 3091030 | 106300 | None | code191 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.All other type of structures(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Tonne | 102556.28 | 102556.28 | 96.16 | False | None | None | False | None | False | 9861811.8848 | 0 | 3091031 | 106300 | None | code192 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Tonne | 116115.19 | 116115.19 | 758.01 | False | None | None | False | None | False | 88016475.1719 | 0 | 3091032 | 106300 | None | code193 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.(BASEMENT FLOOR & GROUND FLOOR & DEVELOPMENT WORKS) ---- etc., complete with all lead | Cum | 128261.87 | 128261.87 | 10.8 | False | None | None | False | None | False | 1385228.196 | 0 | 3091033 | 106300 | None | code194 | Providing & Fixing of corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications.(FIRST FLOOR) ---- etc., complete with all lead | Rmtr | 15.0 | 15.0 | 329.6 | False | None | None | False | None | False | 4944.0 | 0 | 3091034 | 106300 | None | code195 | Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications.(FIRST FLOOR) ---- etc., complete with all lead | Rmtr | 38.94 | 38.94 | 523.4 | False | None | None | False | None | False | 20381.196 | 0 | 3091035 | 106300 | None | code196 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide(FIRST FLOOR) ---- etc., complete with all lead | Rmtr | 49.82 | 49.82 | 9260.8 | False | None | None | False | None | False | 461373.056 | 0 | 3091036 | 106300 | None | code197 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(FIRST FLOOR) ---- etc., complete with all lead | Sqm | 65.55 | 65.55 | 242.1 | False | None | None | False | None | False | 15869.655 | 0 | 3091037 | 106300 | None | code198 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.(FIRST FLOOR) ---- etc., complete with all lead | Rmtr | 68.17 | 68.17 | 1964.9 | False | None | None | False | None | False | 133947.233 | 0 | 3091038 | 106300 | None | code199 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(FIRST FLOOR) ---- etc., complete with all lead | Sqm | 69.48 | 69.48 | 405.5 | False | None | None | False | None | False | 28174.14 | 0 | 3091039 | 106300 | None | code200 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm(FIRST FLOOR) ---- etc., complete with all lead | Nos | 78.66 | 78.66 | 324.0 | False | None | None | False | None | False | 25485.84 | 0 | 3091040 | 106300 | None | code201 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm(FIRST FLOOR) ---- etc., complete with all lead | No | 85.93 | 85.93 | 32.0 | False | None | None | False | None | False | 2749.76 | 0 | 3091041 | 106300 | None | code202 | Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge.(FIRST FLOOR) ---- etc., complete with all lead | Rmtr | 86.14 | 86.14 | 523.4 | False | None | None | False | None | False | 45085.676 | 0 | 3091042 | 106300 | None | code203 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm(FIRST FLOOR) ---- etc., complete with all lead | No | 91.77 | 91.77 | 154.0 | False | None | None | False | None | False | 14132.58 | 0 | 3091043 | 106300 | None | code204 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm(FIRST FLOOR) ---- etc., complete with all lead | No | 122.76 | 122.76 | 54.0 | False | None | None | False | None | False | 6629.04 | 0 | 3091044 | 106300 | None | code205 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(FIRST FLOOR) ---- etc., complete with all lead | Sqm | 131.1 | 131.1 | 11228.7 | False | None | None | False | None | False | 1472082.57 | 0 | 3091045 | 106300 | None | code206 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(FIRST FLOOR) ---- etc., complete with all lead | Sqm | 150.76 | 150.76 | 242.1 | False | None | None | False | None | False | 36498.996 | 0 | 3091046 | 106300 | None | code207 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(FIRST FLOOR) ---- etc., complete with all lead | Sqm | 166.49 | 166.49 | 11228.71 | False | None | None | False | None | False | 1869467.9279 | 0 | 3091047 | 106300 | None | code208 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm(FIRST FLOOR) ---- etc., complete with all lead | No | 184.13 | 184.13 | 94.0 | False | None | None | False | None | False | 17308.22 | 0 | 3091048 | 106300 | None | code209 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 Sqm. Over and including priming coat of exterior primer applied @ 0.90 L/10 Sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(FIRST FLOOR) ---- etc., complete with all lead | Sqm | 204.51 | 204.51 | 1541.71 | False | None | None | False | None | False | 315295.1121 | 0 | 3091049 | 106300 | None | code210 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding(FIRST FLOOR) ---- etc., complete with all lead | Kg | 220.24 | 220.24 | 5084.1 | False | None | None | False | None | False | 1119722.184 | 0 | 3091050 | 106300 | None | code211 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(FIRST FLOOR) ---- etc., complete with all lead | Sqm | 276.62 | 276.62 | 5107.24 | False | None | None | False | None | False | 1412764.7288 | 0 | 3091051 | 106300 | None | code212 | Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer.(FIRST FLOOR) ---- etc., complete with all lead | Sqm | 283.2 | 283.2 | 150.0 | False | None | None | False | None | False | 42480.0 | 0 | 3091052 | 106300 | None | code213 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(FIRST FLOOR) ---- etc., complete with all lead | Sqm | 386.74 | 386.74 | 1930.55 | False | None | None | False | None | False | 746620.907 | 0 | 3091053 | 106300 | None | code214 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside)(FIRST FLOOR) ---- etc., complete with all lead | Sqm | 409.03 | 409.03 | 6121.47 | False | None | None | False | None | False | 2503864.8741 | 0 | 3091054 | 106300 | None | code215 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside)(FIRST FLOOR) ---- etc., complete with all lead | Sqm | 457.53 | 457.53 | 1541.71 | False | None | None | False | None | False | 705378.5763 | 0 | 3091055 | 106300 | None | code216 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge.(FIRST FLOOR) ---- etc., complete with all lead | Sqm | 464.09 | 464.09 | 215.18 | False | None | None | False | None | False | 99862.8862 | 0 | 3091056 | 106300 | None | code217 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm(FIRST FLOOR) ---- etc., complete with all lead | No | 491.62 | 491.62 | 54.0 | False | None | None | False | None | False | 26547.48 | 0 | 3091057 | 106300 | None | code218 | Providing and supplying aluminium extruded tubular and other alu- minium sections as per the architectural drawings and approved draw- ings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment.(FIRST FLOOR) ---- etc., complete with all lead | Kg | 533.57 | 533.57 | 5709.6 | False | None | None | False | None | False | 3046471.272 | 0 | 3091058 | 106300 | None | code219 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in- charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials, labour, usage charges of machinery complete as per specifications.(FIRST FLOOR) ---- etc., complete with all lead | Kg | 592.56 | 592.56 | 720.0 | False | None | None | False | None | False | 426643.2 | 0 | 3091059 | 106300 | None | code220 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Handles 300mm(FIRST FLOOR) ---- etc., complete with all lead | No | 721.04 | 721.04 | 108.0 | False | None | None | False | None | False | 77872.32 | 0 | 3091060 | 106300 | None | code221 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(FIRST FLOOR) ---- etc., complete with all lead | Kg | 740.7 | 740.7 | 1599.36 | False | None | None | False | None | False | 1184645.952 | 0 | 3091061 | 106300 | None | code222 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 Kg/bag of cement. (For calculation purpose 320 Kg of Cement for M-20 grade of Concrete is considered in the analysis)(FIRST FLOOR) ---- etc., complete with all lead | Sqm | 806.25 | 806.25 | 379.05 | False | None | None | False | None | False | 305609.0625 | 0 | 3091062 | 106300 | None | code223 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.
3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.)(FIRST FLOOR) ---- etc., complete with all lead | Sqm | 887.53 | 887.53 | 405.5 | False | None | None | False | None | False | 359893.415 | 0 | 3091063 | 106300 | None | code224 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 Kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately)Size 62 x 100mm(FIRST FLOOR) ---- etc., complete with all lead | m | 920.31 | 920.31 | 273.0 | False | None | None | False | None | False | 251244.63 | 0 | 3091064 | 106300 | None | code225 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 Kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.(FIRST FLOOR) ---- etc., complete with all lead | Sqm | 1165.46 | 1165.46 | 248.56 | False | None | None | False | None | False | 289686.7376 | 0 | 3091065 | 106300 | None | code226 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10Kg/ Sqm) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(FIRST FLOOR) ---- etc., complete with all lead | Sqm | 1295.25 | 1295.25 | 72.0 | False | None | None | False | None | False | 93258.0 | 0 | 3091066 | 106300 | None | code227 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.(FIRST FLOOR) ---- etc., complete with all lead | Nos | 1331.96 | 1331.96 | 54.0 | False | None | None | False | None | False | 71925.84 | 0 | 3091067 | 106300 | None | code228 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.(FIRST FLOOR) ---- etc., complete with all lead | No | 1379.15 | 1379.15 | 54.0 | False | None | None | False | None | False | 74474.1 | 0 | 3091068 | 106300 | None | code229 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800Kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(FIRST FLOOR) ---- etc., complete with all lead | Sqm | 1447.32 | 1447.32 | 425.34 | False | None | None | False | None | False | 615603.0888 | 0 | 3091069 | 106300 | None | code230 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 Kg and door width upto 700 mm), with necessary accessories and screws etc. complete.(FIRST FLOOR) ---- etc., complete with all lead | Nos | 1460.43 | 1460.43 | 79.0 | False | None | None | False | None | False | 115373.97 | 0 | 3091070 | 106300 | None | code231 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 Kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm(FIRST FLOOR) ---- etc., complete with all lead | Sqm | 1540.4 | 1540.4 | 2623.73 | False | None | None | False | None | False | 4041593.692 | 0 | 3091071 | 106300 | None | code232 | Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications.(FIRST FLOOR) ---- etc., complete with all lead | Sqm | 1622.99 | 1622.99 | 12.5 | False | None | None | False | None | False | 20287.375 | 0 | 3091072 | 106300 | None | code233 | Providing and fixing in position 12mm thick plaster of paris (Gypsum anhydrous) for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications.(FIRST FLOOR) ---- etc., complete with all lead | Sqm | 1670.19 | 1670.19 | 1001.2 | False | None | None | False | None | False | 1672194.228 | 0 | 3091073 | 106300 | None | code234 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800Kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(FIRST FLOOR) ---- etc., complete with all lead | Sqm | 1717.38 | 1717.38 | 4417.15 | False | None | None | False | None | False | 7585925.067 | 0 | 3091074 | 106300 | None | code235 | Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm(FIRST FLOOR) ---- etc., complete with all lead | Sqm | 1738.36 | 1738.36 | 980.61 | False | None | None | False | None | False | 1704653.1996 | 0 | 3091075 | 106300 | None | code236 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.(FIRST FLOOR) ---- etc., complete with all lead | Sqm | 1899.61 | 1899.61 | 949.94 | False | None | None | False | None | False | 1804515.5234 | 0 | 3091076 | 106300 | None | code237 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per m2 including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge.(FIRST FLOOR) ---- etc., complete with all lead | Sqm | 2219.49 | 2219.49 | 1501.8 | False | None | None | False | None | False | 3333230.082 | 0 | 3091077 | 106300 | None | code238 | Providing and fixing aluminium coated and polyester based netted curtains complete. The work includes cost of all materials, labour charges, lead and lift, etc., complete.(FIRST FLOOR) ---- etc., complete with all lead | Rmtr | 2596.0 | 2596.0 | 270.0 | False | None | None | False | None | False | 700920.0 | 0 | 3091078 | 106300 | None | code239 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.(FIRST FLOOR) ---- etc., complete with all lead | Cum | 2644.25 | 2644.25 | 68.7 | False | None | None | False | None | False | 181659.975 | 0 | 3091079 | 106300 | None | code240 | Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:(a) Structural analysis & design and preparation d fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.(e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete.This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge.Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the cur- tain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in m2 . up to two decimal places.Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 m2 from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science
& Technologies, India. Cost of testing is payable separately.The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or by any other accreditation body which operates in accordance with ISO / IEC 17011 and accredits labs as per ISO/ IEC 17025.1. Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa)
& (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr. 2. Static Water Penetration Test. (50pa to 1500p) as per ASTME- 331-09 testing method for a range up to 2000 ml.3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml4. Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm,..5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test, Tests to be conducted on site.6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml(FIRST FLOOR) ---- etc., complete with all lead | Sqm | 3519.98 | 3519.98 | 36.0 | False | None | None | False | None | False | 126719.28 | 0 | 3091080 | 106300 | None | code241 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2)For payment, only the actual area of glass on face 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/ m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.(FIRST FLOOR) ---- etc., complete with all lead | Sqm | 3989.31 | 3989.31 | 660.0 | False | None | None | False | None | False | 2632944.6 | 0 | 3091081 | 106300 | None | code242 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-do- 35 mm thick both side Commercial(FIRST FLOOR) ---- etc., complete with all lead | Sqm | 4355.08 | 4355.08 | 168.96 | False | None | None | False | None | False | 735834.3168 | 0 | 3091082 | 106300 | None | code243 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 Kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness(FIRST FLOOR) ---- etc., complete with all lead | Sqm | 4568.77 | 4568.77 | 86.4 | False | None | None | False | None | False | 394741.728 | 0 | 3091083 | 106300 | None | code244 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2(FIRST FLOOR) ---- etc., complete with all lead | Sqm | 5251.79 | 5251.79 | 145.88 | False | None | None | False | None | False | 766131.1252 | 0 | 3091084 | 106300 | None | code245 | Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge.(FIRST FLOOR) ---- etc., complete with all lead | Sqm | 5451.05 | 5451.05 | 249.6 | False | None | None | False | None | False | 1360582.08 | 0 | 3091085 | 106300 | None | code246 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.(FIRST FLOOR) ---- etc., complete with all lead | Sqm | 6984.9 | 6984.9 | 470.23 | False | None | None | False | None | False | 3284509.527 | 0 | 3091086 | 106300 | None | code247 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (FIRST FLOOR) ---- etc., complete with all lead | Sqm | 7497.49 | 7497.49 | 44.28 | False | None | None | False | None | False | 331988.8572 | 0 | 3091087 | 106300 | None | code248 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall
be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)(FIRST FLOOR) ---- etc., complete with all lead | Sqm | 8828.14 | 8828.14 | 197.82 | False | None | None | False | None | False | 1746382.6548 | 0 | 3091088 | 106300 | None | code249 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. CILL/CHEJJA(FIRST FLOOR) ---- etc., complete with all lead | Cum | 12603.11 | 12603.11 | 25.93 | False | None | None | False | None | False | 326798.6423 | 0 | 3091089 | 106300 | None | code250 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. RCC SLAB,STAIRCASE(FIRST FLOOR) ---- etc., complete with all lead | Cum | 13456.55 | 13456.55 | 500.32 | False | None | None | False | None | False | 6732581.096 | 0 | 3091090 | 106300 | None | code251 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. RCC BEAMS,LINTEL(FIRST FLOOR) ---- etc., complete with all lead | Cum | 14353.66 | 14353.66 | 314.14 | False | None | None | False | None | False | 4509058.7524 | 0 | 3091091 | 106300 | None | code252 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. COLUMNS,LIFT CORE WALL(FIRST FLOOR) ---- etc., complete with all lead | Cum | 15250.76 | 15250.76 | 261.98 | False | None | None | False | None | False | 3995394.1048 | 0 | 3091092 | 106300 | None | code253 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.(FIRST FLOOR) ---- etc., complete with all lead | Tonne | 117276.34 | 117276.34 | 163.68 | False | None | None | False | None | False | 19195791.3312 | 0 | 3091093 | 106300 | None | code254 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.(FIRST FLOOR) ---- etc., complete with all lead | Cum | 129544.49 | 129544.49 | 5.21 | False | None | None | False | None | False | 674926.7929 | 0 | 3091094 | 106300 | None | code255 | Providing & Fixing of corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications. (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Rmtr | 15.0 | 15.0 | 303.5 | False | None | None | False | None | False | 4552.5 | 0 | 3091095 | 106300 | None | code256 | Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Rmtr | 38.94 | 38.94 | 477.5 | False | None | None | False | None | False | 18593.85 | 0 | 3091096 | 106300 | None | code257 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Rmtr | 50.31 | 50.31 | 8400.0 | False | None | None | False | None | False | 422604.0 | 0 | 3091097 | 106300 | None | code258 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 66.2 | 66.2 | 214.74 | False | None | None | False | None | False | 14215.788 | 0 | 3091098 | 106300 | None | code259 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Rmtr | 68.85 | 68.85 | 1661.6 | False | None | None | False | None | False | 114401.16 | 0 | 3091099 | 106300 | None | code260 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 70.17 | 70.17 | 393.41 | False | None | None | False | None | False | 27605.5797 | 0 | 3091100 | 106300 | None | code261 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Nos | 79.44 | 79.44 | 294.0 | False | None | None | False | None | False | 23355.36 | 0 | 3091101 | 106300 | None | code262 | Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Rmtr | 86.14 | 86.14 | 539.7 | False | None | None | False | None | False | 46489.758 | 0 | 3091102 | 106300 | None | code263 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | No | 92.68 | 92.68 | 170.0 | False | None | None | False | None | False | 15755.6 | 0 | 3091103 | 106300 | None | code264 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | No | 132.4 | 132.4 | 49.0 | False | None | None | False | None | False | 6487.6 | 0 | 3091104 | 106300 | None | code265 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 132.4 | 132.4 | 9965.57 | False | None | None | False | None | False | 1319441.468 | 0 | 3091105 | 106300 | None | code266 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 152.26 | 152.26 | 214.74 | False | None | None | False | None | False | 32696.3124 | 0 | 3091106 | 106300 | None | code267 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 168.14 | 168.14 | 9965.53 | False | None | None | False | None | False | 1675604.2142 | 0 | 3091107 | 106300 | None | code268 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | No | 198.59 | 198.59 | 81.0 | False | None | None | False | None | False | 16085.79 | 0 | 3091108 | 106300 | None | code269 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 Sqm. Over and including priming coat of exterior primer applied @ 0.90 L/10 Sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 206.54 | 206.54 | 1516.43 | False | None | None | False | None | False | 313203.4522 | 0 | 3091109 | 106300 | None | code270 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Kg | 222.43 | 222.43 | 4449.06 | False | None | None | False | None | False | 989604.4158 | 0 | 3091110 | 106300 | None | code271 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 279.36 | 279.36 | 4723.7 | False | None | None | False | None | False | 1319612.832 | 0 | 3091111 | 106300 | None | code272 | Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 283.2 | 283.2 | 100.0 | False | None | None | False | None | False | 28320.0 | 0 | 3091112 | 106300 | None | code273 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 390.57 | 390.57 | 1702.21 | False | None | None | False | None | False | 664832.1597 | 0 | 3091113 | 106300 | None | code274 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 413.08 | 413.08 | 5241.83 | False | None | None | False | None | False | 2165295.1364 | 0 | 3091114 | 106300 | None | code275 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 462.06 | 462.06 | 1516.43 | False | None | None | False | None | False | 700681.6458 | 0 | 3091115 | 106300 | None | code276 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge. (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 468.68 | 468.68 | 192.52 | False | None | None | False | None | False | 90230.2736 | 0 | 3091116 | 106300 | None | code277 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | No | 496.49 | 496.49 | 49.0 | False | None | None | False | None | False | 24328.01 | 0 | 3091117 | 106300 | None | code278 | Providing and supplying aluminium extruded tubular and other alu- minium sections as per the architectural drawings and approved draw- ings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment. (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Kg | 538.85 | 538.85 | 5475.6 | False | None | None | False | None | False | 2950527.06 | 0 | 3091118 | 106300 | None | code279 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 Kg/sqcm & class 3 (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Rmtr | 544.15 | 544.15 | 90.0 | False | None | None | False | None | False | 48973.5 | 0 | 3091119 | 106300 | None | code280 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in- charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials, labour, usage charges of machinery complete as per specifications. (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Kg | 598.43 | 598.43 | 720.0 | False | None | None | False | None | False | 430869.6 | 0 | 3091120 | 106300 | None | code281 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Handles 300mm (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | No | 728.18 | 728.18 | 98.0 | False | None | None | False | None | False | 71361.64 | 0 | 3091121 | 106300 | None | code282 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Kg | 748.04 | 748.04 | 1455.3 | False | None | None | False | None | False | 1088622.612 | 0 | 3091122 | 106300 | None | code283 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 Kg/bag of cement. (For calculation purpose 320 Kg of Cement for M-20 grade of Concrete is considered in the analysis) (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 814.24 | 814.24 | 334.05 | False | None | None | False | None | False | 271996.872 | 0 | 3091123 | 106300 | None | code284 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.
3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 896.32 | 896.32 | 393.41 | False | None | None | False | None | False | 352621.2512 | 0 | 3091124 | 106300 | None | code285 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 Kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately)Size 62 x 100mm (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | m | 929.42 | 929.42 | 180.0 | False | None | None | False | None | False | 167295.6 | 0 | 3091125 | 106300 | None | code286 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 Kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 1177.0 | 1177.0 | 220.6 | False | None | None | False | None | False | 259646.2 | 0 | 3091126 | 106300 | None | code287 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10Kg/ Sqm) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 1308.07 | 1308.07 | 72.0 | False | None | None | False | None | False | 94181.04 | 0 | 3091127 | 106300 | None | code288 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Nos | 1345.14 | 1345.14 | 49.0 | False | None | None | False | None | False | 65911.86 | 0 | 3091128 | 106300 | None | code289 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | No | 1392.81 | 1392.81 | 49.0 | False | None | None | False | None | False | 68247.69 | 0 | 3091129 | 106300 | None | code290 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800Kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 1461.65 | 1461.65 | 347.58 | False | None | None | False | None | False | 508040.307 | 0 | 3091130 | 106300 | None | code291 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 Kg and door width upto 700 mm), with necessary accessories and screws etc. complete. (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Nos | 1474.89 | 1474.89 | 69.0 | False | None | None | False | None | False | 101767.41 | 0 | 3091131 | 106300 | None | code292 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 Kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 1555.65 | 1555.65 | 2455.14 | False | None | None | False | None | False | 3819338.541 | 0 | 3091132 | 106300 | None | code293 | Roof Water Proofing. Surface Preparation: remove all surface laitance and contamination free from loose aggregate or other sharp protrusions with fairly smooth finish by wire brush and grinding method and surface shall be DRY for application of single component pitch modified polyurethane cures by reaction with atmospheric moisture to given a tough elastomeric waterproof membrane.
System : Provide and applying 1.2 mm thick roller applied single component bitumen modified polyurathene coating NITPROOF 600 or equivalent, having elongation capacity of 450 % as per ASTM D412, having Tensile strength 1.5 n/mm2 as per ASTM D 412, Tear resistance of 15 N as per ASTM D 624 and having shore A Hardness 50 as per ASTM D 2240. Waterproofing treatment to be provided after proper surface preparation as per Manufacture Specification.
Protection of waterproofing system with minimum 50 mm thick screed and providing construction joints and sealing the same with PU sealant.TERRACE FLOOR
(SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 1593.0 | 1593.0 | 354.0 | False | None | None | False | None | False | 563922.0 | 0 | 3091133 | 106300 | None | code294 | Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications. (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 1639.06 | 1639.06 | 12.5 | False | None | None | False | None | False | 20488.25 | 0 | 3091134 | 106300 | None | code295 | Providing and fixing in position 12mm thick plaster of paris (Gypsum anhydrous) for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications. (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 1686.73 | 1686.73 | 982.1 | False | None | None | False | None | False | 1656537.533 | 0 | 3091135 | 106300 | None | code296 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800Kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 1734.39 | 1734.39 | 3912.24 | False | None | None | False | None | False | 6785349.9336 | 0 | 3091136 | 106300 | None | code297 | Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 1755.57 | 1755.57 | 851.28 | False | None | None | False | None | False | 1494481.6296 | 0 | 3091137 | 106300 | None | code298 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 1918.42 | 1918.42 | 850.93 | False | None | None | False | None | False | 1632441.1306 | 0 | 3091138 | 106300 | None | code299 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per m2 including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 2241.46 | 2241.46 | 1473.1 | False | None | None | False | None | False | 3301894.726 | 0 | 3091139 | 106300 | None | code300 | Providing and fixing aluminium coated and polyester based netted curtains complete. The work includes cost of all materials, labour charges, lead and lift, etc., complete. (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Rmtr | 2596.0 | 2596.0 | 250.0 | False | None | None | False | None | False | 649000.0 | 0 | 3091140 | 106300 | None | code301 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Cum | 2670.43 | 2670.43 | 66.18 | False | None | None | False | None | False | 176729.0574 | 0 | 3091141 | 106300 | None | code302 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2)For payment, only the actual area of glass on face 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face , + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/ m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 4028.81 | 4028.81 | 624.0 | False | None | None | False | None | False | 2513977.44 | 0 | 3091142 | 106300 | None | code303 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-do- 35 mm thick both side Commercial (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 4398.2 | 4398.2 | 163.92 | False | None | None | False | None | False | 720952.944 | 0 | 3091143 | 106300 | None | code304 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 Kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 4614.0 | 4614.0 | 56.7 | False | None | None | False | None | False | 261613.8 | 0 | 3091144 | 106300 | None | code305 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2 (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 5303.78 | 5303.78 | 134.66 | False | None | None | False | None | False | 714207.0148 | 0 | 3091145 | 106300 | None | code306 | Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge. (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 5505.03 | 5505.03 | 249.6 | False | None | None | False | None | False | 1374055.488 | 0 | 3091146 | 106300 | None | code307 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 5928.69 | 5928.69 | 2.88 | False | None | None | False | None | False | 17074.6272 | 0 | 3091147 | 106300 | None | code308 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 7054.06 | 7054.06 | 441.89 | False | None | None | False | None | False | 3117118.5734 | 0 | 3091148 | 106300 | None | code309 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 7571.73 | 7571.73 | 39.96 | False | None | None | False | None | False | 302566.3308 | 0 | 3091149 | 106300 | None | code310 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall
be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 8915.55 | 8915.55 | 171.9 | False | None | None | False | None | False | 1532583.045 | 0 | 3091150 | 106300 | None | code311 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. CILL/CHEJJA (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Cum | 12727.89 | 12727.89 | 24.01 | False | None | None | False | None | False | 305596.6389 | 0 | 3091151 | 106300 | None | code312 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. .RCC SLAB,STAIRCASE (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Cum | 13589.79 | 13589.79 | 476.62 | False | None | None | False | None | False | 6477165.7098 | 0 | 3091152 | 106300 | None | code313 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. .RCC BEAMS,LINTEL (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Cum | 14495.77 | 14495.77 | 293.47 | False | None | None | False | None | False | 4254073.6219 | 0 | 3091153 | 106300 | None | code314 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. .COLUMNS,LIFT CORE WALL (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Cum | 15401.76 | 15401.76 | 253.91 | False | None | None | False | None | False | 3910660.8816 | 0 | 3091154 | 106300 | None | code315 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Tonne | 118437.49 | 118437.49 | 157.66 | False | None | None | False | None | False | 18672854.6734 | 0 | 3091155 | 106300 | None | code316 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (SECOND FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Cum | 130827.11 | 130827.11 | 5.59 | False | None | None | False | None | False | 731323.5449 | 0 | 3091156 | 106300 | None | code317 | Providing & Fixing of corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications. (THIRD FLOOR) ---- etc., complete with all lead | Rmtr | 15.0 | 15.0 | 304.1 | False | None | None | False | None | False | 4561.5 | 0 | 3091157 | 106300 | None | code318 | Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. (THIRD FLOOR) ---- etc., complete with all lead | Rmtr | 38.94 | 38.94 | 492.0 | False | None | None | False | None | False | 19158.48 | 0 | 3091158 | 106300 | None | code319 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide (THIRD FLOOR) ---- etc., complete with all lead | Rmtr | 50.8 | 50.8 | 8400.0 | False | None | None | False | None | False | 426720.0 | 0 | 3091159 | 106300 | None | code320 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (THIRD FLOOR) ---- etc., complete with all lead | Sqm | 66.85 | 66.85 | 219.18 | False | None | None | False | None | False | 14652.183 | 0 | 3091160 | 106300 | None | code321 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. (THIRD FLOOR) ---- etc., complete with all lead | Rmtr | 69.52 | 69.52 | 1661.9 | False | None | None | False | None | False | 115535.288 | 0 | 3091161 | 106300 | None | code322 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (THIRD FLOOR) ---- etc., complete with all lead | Sqm | 70.86 | 70.86 | 396.86 | False | None | None | False | None | False | 28121.4996 | 0 | 3091162 | 106300 | None | code323 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm (THIRD FLOOR) ---- etc., complete with all lead | Nos | 80.22 | 80.22 | 294.0 | False | None | None | False | None | False | 23584.68 | 0 | 3091163 | 106300 | None | code324 | Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. (THIRD FLOOR) ---- etc., complete with all lead | Rmtr | 86.14 | 86.14 | 492.0 | False | None | None | False | None | False | 42380.88 | 0 | 3091164 | 106300 | None | code325 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm (THIRD FLOOR) ---- etc., complete with all lead | No | 93.59 | 93.59 | 172.0 | False | None | None | False | None | False | 16097.48 | 0 | 3091165 | 106300 | None | code326 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm (THIRD FLOOR) ---- etc., complete with all lead | No | 133.69 | 133.69 | 49.0 | False | None | None | False | None | False | 6550.81 | 0 | 3091166 | 106300 | None | code327 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (THIRD FLOOR) ---- etc., complete with all lead | Sqm | 133.69 | 133.69 | 10146.5 | False | None | None | False | None | False | 1356485.585 | 0 | 3091167 | 106300 | None | code328 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (THIRD FLOOR) ---- etc., complete with all lead | Sqm | 153.75 | 153.75 | 219.18 | False | None | None | False | None | False | 33698.925 | 0 | 3091168 | 106300 | None | code329 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (THIRD FLOOR) ---- etc., complete with all lead | Sqm | 169.79 | 169.79 | 10146.53 | False | None | None | False | None | False | 1722779.3287 | 0 | 3091169 | 106300 | None | code330 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm (THIRD FLOOR) ---- etc., complete with all lead | No | 200.54 | 200.54 | 81.0 | False | None | None | False | None | False | 16243.74 | 0 | 3091170 | 106300 | None | code331 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 Sqm. Over and including priming coat of exterior primer applied @ 0.90 L/10 Sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (THIRD FLOOR) ---- etc., complete with all lead | Sqm | 208.56 | 208.56 | 1234.17 | False | None | None | False | None | False | 257398.4952 | 0 | 3091171 | 106300 | None | code332 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding (THIRD FLOOR) ---- etc., complete with all lead | Kg | 224.61 | 224.61 | 4602.78 | False | None | None | False | None | False | 1033830.4158 | 0 | 3091172 | 106300 | None | code333 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (THIRD FLOOR) ---- etc., complete with all lead | Sqm | 282.09 | 282.09 | 5057.26 | False | None | None | False | None | False | 1426602.4734 | 0 | 3091173 | 106300 | None | code334 | Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. (THIRD FLOOR) ---- etc., complete with all lead | Sqm | 283.2 | 283.2 | 100.0 | False | None | None | False | None | False | 28320.0 | 0 | 3091174 | 106300 | None | code335 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (THIRD FLOOR) ---- etc., complete with all lead | Sqm | 394.4 | 394.4 | 1665.37 | False | None | None | False | None | False | 656821.928 | 0 | 3091175 | 106300 | None | code336 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) (THIRD FLOOR) ---- etc., complete with all lead | Sqm | 417.13 | 417.13 | 5089.27 | False | None | None | False | None | False | 2122887.1951 | 0 | 3091176 | 106300 | None | code337 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) (THIRD FLOOR) ---- etc., complete with all lead | Sqm | 466.59 | 466.59 | 1234.17 | False | None | None | False | None | False | 575851.3803 | 0 | 3091177 | 106300 | None | code338 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge. (THIRD FLOOR) ---- etc., complete with all lead | Sqm | 473.28 | 473.28 | 192.52 | False | None | None | False | None | False | 91115.8656 | 0 | 3091178 | 106300 | None | code339 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm (THIRD FLOOR) ---- etc., complete with all lead | No | 501.35 | 501.35 | 49.0 | False | None | None | False | None | False | 24566.15 | 0 | 3091179 | 106300 | None | code340 | Providing and supplying aluminium extruded tubular and other alu- minium sections as per the architectural drawings and approved draw- ings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment. (THIRD FLOOR) ---- etc., complete with all lead | Kg | 544.13 | 544.13 | 5475.6 | False | None | None | False | None | False | 2979438.228 | 0 | 3091180 | 106300 | None | code341 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in- charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials, labour, usage charges of machinery complete as per specifications. (THIRD FLOOR) ---- etc., complete with all lead | Kg | 604.3 | 604.3 | 720.0 | False | None | None | False | None | False | 435096.0 | 0 | 3091181 | 106300 | None | code342 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Handles 300mm (THIRD FLOOR) ---- etc., complete with all lead | No | 735.32 | 735.32 | 98.0 | False | None | None | False | None | False | 72061.36 | 0 | 3091182 | 106300 | None | code343 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (THIRD FLOOR) ---- etc., complete with all lead | Kg | 755.37 | 755.37 | 1455.3 | False | None | None | False | None | False | 1099289.961 | 0 | 3091183 | 106300 | None | code344 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 Kg/bag of cement. (For calculation purpose 320 Kg of Cement for M-20 grade of Concrete is considered in the analysis) (THIRD FLOOR) ---- etc., complete with all lead | Sqm | 822.22 | 822.22 | 317.82 | False | None | None | False | None | False | 261317.9604 | 0 | 3091184 | 106300 | None | code345 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.
3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) (THIRD FLOOR) ---- etc., complete with all lead | Sqm | 905.11 | 905.11 | 396.86 | False | None | None | False | None | False | 359201.9546 | 0 | 3091185 | 106300 | None | code346 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 Kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately)Size 62 x 100mm (THIRD FLOOR) ---- etc., complete with all lead | m | 938.53 | 938.53 | 156.0 | False | None | None | False | None | False | 146410.68 | 0 | 3091186 | 106300 | None | code347 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 Kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. (THIRD FLOOR) ---- etc., complete with all lead | Sqm | 1188.54 | 1188.54 | 209.92 | False | None | None | False | None | False | 249498.3168 | 0 | 3091187 | 106300 | None | code348 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10Kg/ Sqm) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (THIRD FLOOR) ---- etc., complete with all lead | Sqm | 1320.9 | 1320.9 | 72.0 | False | None | None | False | None | False | 95104.8 | 0 | 3091188 | 106300 | None | code349 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. (THIRD FLOOR) ---- etc., complete with all lead | Nos | 1358.33 | 1358.33 | 49.0 | False | None | None | False | None | False | 66558.17 | 0 | 3091189 | 106300 | None | code350 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. (THIRD FLOOR) ---- etc., complete with all lead | No | 1406.46 | 1406.46 | 49.0 | False | None | None | False | None | False | 68916.54 | 0 | 3091190 | 106300 | None | code351 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800Kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (THIRD FLOOR) ---- etc., complete with all lead | Sqm | 1475.98 | 1475.98 | 355.14 | False | None | None | False | None | False | 524179.5372 | 0 | 3091191 | 106300 | None | code352 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 Kg and door width upto 700 mm), with necessary accessories and screws etc. complete. (THIRD FLOOR) ---- etc., complete with all lead | Nos | 1489.35 | 1489.35 | 69.0 | False | None | None | False | None | False | 102765.15 | 0 | 3091192 | 106300 | None | code353 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 Kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm (THIRD FLOOR) ---- etc., complete with all lead | Sqm | 1570.9 | 1570.9 | 2408.1 | False | None | None | False | None | False | 3782884.29 | 0 | 3091193 | 106300 | None | code354 | Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications. (THIRD FLOOR) ---- etc., complete with all lead | Sqm | 1655.13 | 1655.13 | 12.5 | False | None | None | False | None | False | 20689.125 | 0 | 3091194 | 106300 | None | code355 | Providing and fixing in position 12mm thick plaster of paris (Gypsum anhydrous) for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications. (THIRD FLOOR) ---- etc., complete with all lead | Sqm | 1703.26 | 1703.26 | 963.2 | False | None | None | False | None | False | 1640580.032 | 0 | 3091195 | 106300 | None | code356 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800Kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (THIRD FLOOR) ---- etc., complete with all lead | Sqm | 1751.39 | 1751.39 | 3782.65 | False | None | None | False | None | False | 6624895.3835 | 0 | 3091196 | 106300 | None | code357 | Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm (THIRD FLOOR) ---- etc., complete with all lead | Sqm | 1772.78 | 1772.78 | 851.28 | False | None | None | False | None | False | 1509132.1584 | 0 | 3091197 | 106300 | None | code358 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. (THIRD FLOOR) ---- etc., complete with all lead | Sqm | 1937.23 | 1937.23 | 814.09 | False | None | None | False | None | False | 1577079.5707 | 0 | 3091198 | 106300 | None | code359 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per m2 including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. (THIRD FLOOR) ---- etc., complete with all lead | Sqm | 2263.44 | 2263.44 | 1444.9 | False | None | None | False | None | False | 3270444.456 | 0 | 3091199 | 106300 | None | code360 | Providing and fixing aluminium coated and polyester based netted curtains complete. The work includes cost of all materials, labour charges, lead and lift, etc., complete. (THIRD FLOOR) ---- etc., complete with all lead | Rmtr | 2596.0 | 2596.0 | 250.0 | False | None | None | False | None | False | 649000.0 | 0 | 3091200 | 106300 | None | code361 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. (THIRD FLOOR) ---- etc., complete with all lead | Cum | 2696.61 | 2696.61 | 62.97 | False | None | None | False | None | False | 169805.5317 | 0 | 3091201 | 106300 | None | code362 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2)For payment, only the actual area of glass on face 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/ m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. (THIRD FLOOR) ---- etc., complete with all lead | Sqm | 4068.31 | 4068.31 | 624.0 | False | None | None | False | None | False | 2538625.44 | 0 | 3091202 | 106300 | None | code363 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-do- 35 mm thick both side Commercial (THIRD FLOOR) ---- etc., complete with all lead | Sqm | 4441.31 | 4441.31 | 165.36 | False | None | None | False | None | False | 734415.0216 | 0 | 3091203 | 106300 | None | code364 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 Kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness (THIRD FLOOR) ---- etc., complete with all lead | Sqm | 4659.24 | 4659.24 | 49.14 | False | None | None | False | None | False | 228955.0536 | 0 | 3091204 | 106300 | None | code365 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2 (THIRD FLOOR) ---- etc., complete with all lead | Sqm | 5355.78 | 5355.78 | 134.66 | False | None | None | False | None | False | 721209.3348 | 0 | 3091205 | 106300 | None | code366 | Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge. (THIRD FLOOR) ---- etc., complete with all lead | Sqm | 5559.0 | 5559.0 | 249.6 | False | None | None | False | None | False | 1387526.4 | 0 | 3091206 | 106300 | None | code367 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. (THIRD FLOOR) ---- etc., complete with all lead | Sqm | 7123.22 | 7123.22 | 446.69 | False | None | None | False | None | False | 3181871.1418 | 0 | 3091207 | 106300 | None | code368 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (THIRD FLOOR) ---- etc., complete with all lead | Sqm | 7645.96 | 7645.96 | 40.68 | False | None | None | False | None | False | 311037.6528 | 0 | 3091208 | 106300 | None | code369 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall
be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (THIRD FLOOR) ---- etc., complete with all lead | Sqm | 9002.95 | 9002.95 | 178.5 | False | None | None | False | None | False | 1607026.575 | 0 | 3091209 | 106300 | None | code370 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. CILL/CHEJJA (THIRD FLOOR) ---- etc., complete with all lead | Cum | 12852.67 | 12852.67 | 24.79 | False | None | None | False | None | False | 318617.6893 | 0 | 3091210 | 106300 | None | code371 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. RCC SLAB,STAIRCASE. (THIRD FLOOR) ---- etc., complete with all lead | Cum | 13723.02 | 13723.02 | 452.3 | False | None | None | False | None | False | 6206921.946 | 0 | 3091211 | 106300 | None | code372 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. RCC BEAMS,LINTEL (THIRD FLOOR) ---- etc., complete with all lead | Cum | 14637.89 | 14637.89 | 338.81 | False | None | None | False | None | False | 4959463.5109 | 0 | 3091212 | 106300 | None | code373 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. COLUMNS,LIFT CORE WALL (THIRD FLOOR) ---- etc., complete with all lead | Cum | 15552.76 | 15552.76 | 248.35 | False | None | None | False | None | False | 3862527.946 | 0 | 3091213 | 106300 | None | code374 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (THIRD FLOOR) ---- etc., complete with all lead | Tonne | 119598.64 | 119598.64 | 159.22 | False | None | None | False | None | False | 19042495.4608 | 0 | 3091214 | 106300 | None | code375 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (THIRD FLOOR) ---- etc., complete with all lead | Cum | 132109.73 | 132109.73 | 5.6 | False | None | None | False | None | False | 739814.488 | 0 | 3091215 | 106300 | None | code376 | Providing & Fixing of corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications.(FOURTH FLOOR) ---- etc., complete with all lead | Rmtr | 15.0 | 15.0 | 457.3 | False | None | None | False | None | False | 6859.5 | 0 | 3091216 | 106300 | None | code377 | Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications.(FOURTH FLOOR) ---- etc., complete with all lead | Rmtr | 38.94 | 38.94 | 407.8 | False | None | None | False | None | False | 15879.732 | 0 | 3091217 | 106300 | None | code378 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide(FOURTH FLOOR) ---- etc., complete with all lead | Rmtr | 51.3 | 51.3 | 8400.0 | False | None | None | False | None | False | 430920.0 | 0 | 3091218 | 106300 | None | code379 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(FOURTH FLOOR) ---- etc., complete with all lead | Sqm | 67.5 | 67.5 | 178.08 | False | None | None | False | None | False | 12020.4 | 0 | 3091219 | 106300 | None | code380 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.(FOURTH FLOOR) ---- etc., complete with all lead | Rmtr | 70.2 | 70.2 | 1661.6 | False | None | None | False | None | False | 116644.32 | 0 | 3091220 | 106300 | None | code381 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(FOURTH FLOOR) ---- etc., complete with all lead | Sqm | 71.55 | 71.55 | 615.74 | False | None | None | False | None | False | 44056.197 | 0 | 3091221 | 106300 | None | code382 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm(FOURTH FLOOR) ---- etc., complete with all lead | Nos | 81.0 | 81.0 | 438.0 | False | None | None | False | None | False | 35478.0 | 0 | 3091222 | 106300 | None | code383 | Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge.(FOURTH FLOOR) ---- etc., complete with all lead | Rmtr | 86.14 | 86.14 | 407.8 | False | None | None | False | None | False | 35127.892 | 0 | 3091223 | 106300 | None | code384 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm(FOURTH FLOOR) ---- etc., complete with all lead | No | 94.49 | 94.49 | 258.0 | False | None | None | False | None | False | 24378.42 | 0 | 3091224 | 106300 | None | code385 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm(FOURTH FLOOR) ---- etc., complete with all lead | No | 134.99 | 134.99 | 50.0 | False | None | None | False | None | False | 6749.5 | 0 | 3091225 | 106300 | None | code386 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(FOURTH FLOOR) ---- etc., complete with all lead | Sqm | 134.99 | 134.99 | 11183.5 | False | None | None | False | None | False | 1509660.665 | 0 | 3091226 | 106300 | None | code387 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(FOURTH FLOOR) ---- etc., complete with all lead | Sqm | 155.24 | 155.24 | 178.08 | False | None | None | False | None | False | 27645.1392 | 0 | 3091227 | 106300 | None | code388 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(FOURTH FLOOR) ---- etc., complete with all lead | Sqm | 171.44 | 171.44 | 11183.52 | False | None | None | False | None | False | 1917302.6688 | 0 | 3091228 | 106300 | None | code389 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm(FOURTH FLOOR) ---- etc., complete with all lead | No | 202.49 | 202.49 | 123.0 | False | None | None | False | None | False | 24906.27 | 0 | 3091229 | 106300 | None | code390 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 Sqm. Over and including priming coat of exterior primer applied @ 0.90 L/10 Sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(FOURTH FLOOR) ---- etc., complete with all lead | Sqm | 210.59 | 210.59 | 1271.85 | False | None | None | False | None | False | 267838.8915 | 0 | 3091230 | 106300 | None | code391 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding(FOURTH FLOOR) ---- etc., complete with all lead | Kg | 226.79 | 226.79 | 3739.68 | False | None | None | False | None | False | 848122.0272 | 0 | 3091231 | 106300 | None | code392 | Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer.(FOURTH FLOOR) ---- etc., complete with all lead | Sqm | 283.2 | 283.2 | 100.0 | False | None | None | False | None | False | 28320.0 | 0 | 3091232 | 106300 | None | code393 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(FOURTH FLOOR) ---- etc., complete with all lead | Sqm | 284.83 | 284.83 | 4862.9 | False | None | None | False | None | False | 1385099.807 | 0 | 3091233 | 106300 | None | code394 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(FOURTH FLOOR) ---- etc., complete with all lead | Sqm | 398.23 | 398.23 | 1976.26 | False | None | None | False | None | False | 787006.0198 | 0 | 3091234 | 106300 | None | code395 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside)(FOURTH FLOOR) ---- etc., complete with all lead | Sqm | 421.18 | 421.18 | 6320.63 | False | None | None | False | None | False | 2662122.9434 | 0 | 3091235 | 106300 | None | code396 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside)(FOURTH FLOOR) ---- etc., complete with all lead | Sqm | 471.12 | 471.12 | 1271.85 | False | None | None | False | None | False | 599193.972 | 0 | 3091236 | 106300 | None | code397 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge.(FOURTH FLOOR) ---- etc., complete with all lead | Sqm | 477.87 | 477.87 | 192.52 | False | None | None | False | None | False | 91999.5324 | 0 | 3091237 | 106300 | None | code398 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm(FOURTH FLOOR) ---- etc., complete with all lead | No | 506.22 | 506.22 | 73.0 | False | None | None | False | None | False | 36954.06 | 0 | 3091238 | 106300 | None | code399 | Providing and supplying aluminium extruded tubular and other alu- minium sections as per the architectural drawings and approved draw- ings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment.(FOURTH FLOOR) ---- etc., complete with all lead | Kg | 549.42 | 549.42 | 5475.6 | False | None | None | False | None | False | 3008404.152 | 0 | 3091239 | 106300 | None | code400 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in- charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials, labour, usage charges of machinery complete as per specifications.(FOURTH FLOOR) ---- etc., complete with all lead | Kg | 610.16 | 610.16 | 720.0 | False | None | None | False | None | False | 439315.2 | 0 | 3091240 | 106300 | None | code401 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Handles 300mm(FOURTH FLOOR) ---- etc., complete with all lead | No | 742.46 | 742.46 | 146.0 | False | None | None | False | None | False | 108399.16 | 0 | 3091241 | 106300 | None | code402 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(FOURTH FLOOR) ---- etc., complete with all lead | Kg | 762.7 | 762.7 | 1455.3 | False | None | None | False | None | False | 1109957.31 | 0 | 3091242 | 106300 | None | code403 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 Kg/bag of cement. (For calculation purpose 320 Kg of Cement for M-20 grade of Concrete is considered in the analysis)(FOURTH FLOOR) ---- etc., complete with all lead | Sqm | 830.2 | 830.2 | 508.5 | False | None | None | False | None | False | 422156.7 | 0 | 3091243 | 106300 | None | code404 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.
3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.)(FOURTH FLOOR) ---- etc., complete with all lead | Sqm | 913.9 | 913.9 | 615.74 | False | None | None | False | None | False | 562724.786 | 0 | 3091244 | 106300 | None | code405 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 Kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately)Size 62 x 100mm(FOURTH FLOOR) ---- etc., complete with all lead | m | 947.64 | 947.64 | 264.0 | False | None | None | False | None | False | 250176.96 | 0 | 3091245 | 106300 | None | code406 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 Kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.(FOURTH FLOOR) ---- etc., complete with all lead | Sqm | 1200.08 | 1200.08 | 340.39 | False | None | None | False | None | False | 408495.2312 | 0 | 3091246 | 106300 | None | code407 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10Kg/ Sqm) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(FOURTH FLOOR) ---- etc., complete with all lead | Sqm | 1333.72 | 1333.72 | 72.0 | False | None | None | False | None | False | 96027.84 | 0 | 3091247 | 106300 | None | code408 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.(FOURTH FLOOR) ---- etc., complete with all lead | Nos | 1371.52 | 1371.52 | 73.0 | False | None | None | False | None | False | 100120.96 | 0 | 3091248 | 106300 | None | code409 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.(FOURTH FLOOR) ---- etc., complete with all lead | No | 1420.12 | 1420.12 | 73.0 | False | None | None | False | None | False | 103668.76 | 0 | 3091249 | 106300 | None | code410 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800Kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(FOURTH FLOOR) ---- etc., complete with all lead | Sqm | 1490.31 | 1490.31 | 362.52 | False | None | None | False | None | False | 540267.1812 | 0 | 3091250 | 106300 | None | code411 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 Kg and door width upto 700 mm), with necessary accessories and screws etc. complete.(FOURTH FLOOR) ---- etc., complete with all lead | Nos | 1503.81 | 1503.81 | 93.0 | False | None | None | False | None | False | 139854.33 | 0 | 3091251 | 106300 | None | code412 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 Kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm(FOURTH FLOOR) ---- etc., complete with all lead | Sqm | 1586.16 | 1586.16 | 2238.62 | False | None | None | False | None | False | 3550809.4992 | 0 | 3091252 | 106300 | None | code413 | Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications.(FOURTH FLOOR) ---- etc., complete with all lead | Sqm | 1671.2 | 1671.2 | 12.5 | False | None | None | False | None | False | 20890.0 | 0 | 3091253 | 106300 | None | code414 | Providing and fixing in position 12mm thick plaster of paris (Gypsum anhydrous) for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications.(FOURTH FLOOR) ---- etc., complete with all lead | Sqm | 1719.8 | 1719.8 | 895.4 | False | None | None | False | None | False | 1539908.92 | 0 | 3091254 | 106300 | None | code415 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800Kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(FOURTH FLOOR) ---- etc., complete with all lead | Sqm | 1768.4 | 1768.4 | 4526.45 | False | None | None | False | None | False | 8004574.18 | 0 | 3091255 | 106300 | None | code416 | Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm(FOURTH FLOOR) ---- etc., complete with all lead | Sqm | 1789.99 | 1789.99 | 985.75 | False | None | None | False | None | False | 1764482.6425 | 0 | 3091256 | 106300 | None | code417 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.(FOURTH FLOOR) ---- etc., complete with all lead | Sqm | 1956.03 | 1956.03 | 990.5 | False | None | None | False | None | False | 1937447.715 | 0 | 3091257 | 106300 | None | code418 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per m2 including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge.(FOURTH FLOOR) ---- etc., complete with all lead | Sqm | 2285.41 | 2285.41 | 1343.2 | False | None | None | False | None | False | 3069762.712 | 0 | 3091258 | 106300 | None | code419 | Providing and fixing aluminium coated and polyester based netted curtains complete. The work includes cost of all materials, labour charges, lead and lift, etc., complete.(FOURTH FLOOR) ---- etc., complete with all lead | Rmtr | 2596.0 | 2596.0 | 250.0 | False | None | None | False | None | False | 649000.0 | 0 | 3091259 | 106300 | None | code420 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.(FOURTH FLOOR) ---- etc., complete with all lead | Cum | 2722.79 | 2722.79 | 102.12 | False | None | None | False | None | False | 278051.3148 | 0 | 3091260 | 106300 | None | code421 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2)For payment, only the actual area of glass on face 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/ m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.(FOURTH FLOOR) ---- etc., complete with all lead | Sqm | 4107.81 | 4107.81 | 624.0 | False | None | None | False | None | False | 2563273.44 | 0 | 3091261 | 106300 | None | code422 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-do- 35 mm thick both side Commercial(FOURTH FLOOR) ---- etc., complete with all lead | Sqm | 4484.43 | 4484.43 | 256.56 | False | None | None | False | None | False | 1150525.3608 | 0 | 3091262 | 106300 | None | code423 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 Kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness(FOURTH FLOOR) ---- etc., complete with all lead | Sqm | 4704.47 | 4704.47 | 83.16 | False | None | None | False | None | False | 391223.7252 | 0 | 3091263 | 106300 | None | code424 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2(FOURTH FLOOR) ---- etc., complete with all lead | Sqm | 5407.78 | 5407.78 | 134.66 | False | None | None | False | None | False | 728211.6548 | 0 | 3091264 | 106300 | None | code425 | Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge.(FOURTH FLOOR) ---- etc., complete with all lead | Sqm | 5612.97 | 5612.97 | 249.6 | False | None | None | False | None | False | 1400997.312 | 0 | 3091265 | 106300 | None | code426 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.(FOURTH FLOOR) ---- etc., complete with all lead | Sqm | 7192.37 | 7192.37 | 441.89 | False | None | None | False | None | False | 3178236.3793 | 0 | 3091266 | 106300 | None | code427 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (FOURTH FLOOR) ---- etc., complete with all lead | Sqm | 7720.19 | 7720.19 | 38.34 | False | None | None | False | None | False | 295992.0846 | 0 | 3091267 | 106300 | None | code428 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall
be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)(FOURTH FLOOR) ---- etc., complete with all lead | Sqm | 9090.36 | 9090.36 | 139.74 | False | None | None | False | None | False | 1270286.9064 | 0 | 3091268 | 106300 | None | code429 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. CILL/CHEJJA(FOURTH FLOOR) ---- etc., complete with all lead | Cum | 12977.46 | 12977.46 | 19.52 | False | None | None | False | None | False | 253320.0192 | 0 | 3091269 | 106300 | None | code430 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. RCC SLAB,STAIRCASE.(FOURTH FLOOR) ---- etc., complete with all lead | Cum | 13856.25 | 13856.25 | 475.73 | False | None | None | False | None | False | 6591833.8125 | 0 | 3091270 | 106300 | None | code431 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. RCC BEAMS,LINTEL(FOURTH FLOOR) ---- etc., complete with all lead | Cum | 14780.0 | 14780.0 | 300.15 | False | None | None | False | None | False | 4436217.0 | 0 | 3091271 | 106300 | None | code432 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. COLUMNS,LIFT CORE WALL(FOURTH FLOOR) ---- etc., complete with all lead | Cum | 15703.75 | 15703.75 | 248.73 | False | None | None | False | None | False | 3905993.7375 | 0 | 3091272 | 106300 | None | code433 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.(FOURTH FLOOR) ---- etc., complete with all lead | Tonne | 120759.79 | 120759.79 | 152.65 | False | None | None | False | None | False | 18433981.9435 | 0 | 3091273 | 106300 | None | code434 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.(FOURTH FLOOR) ---- etc., complete with all lead | Cum | 133392.34 | 133392.34 | 8.36 | False | None | None | False | None | False | 1115159.9624 | 0 | 3091274 | 106300 | None | code435 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.COLUMNS(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Cum | 15854.75 | 15854.75 | 109.91 | False | None | None | False | None | False | 1742595.5725 | 0 | 3091275 | 106300 | None | code436 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.RCC BEAMS(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Cum | 14922.12 | 14922.12 | 137.48 | False | None | None | False | None | False | 2051493.0576 | 0 | 3091276 | 106300 | None | code437 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.RCC SLAB(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Cum | 13989.49 | 13989.49 | 246.57 | False | None | None | False | None | False | 3449388.5493 | 0 | 3091277 | 106300 | None | code438 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.CILL/CHEJJA(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Cum | 13102.24 | 13102.24 | 9.94 | False | None | None | False | None | False | 130236.2656 | 0 | 3091278 | 106300 | None | code439 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Tonne | 121920.95 | 121920.95 | 69.54 | False | None | None | False | None | False | 8478382.863 | 0 | 3091279 | 106300 | None | code440 | Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications.(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Rmtr | 38.94 | 38.94 | 201.7 | False | None | None | False | None | False | 7854.198 | 0 | 3091280 | 106300 | None | code441 | Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge.(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Rmtr | 86.14 | 86.14 | 440.7 | False | None | None | False | None | False | 37961.898 | 0 | 3091281 | 106300 | None | code442 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800Kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 1785.4 | 1785.4 | 1046.16 | False | None | None | False | None | False | 1867814.064 | 0 | 3091282 | 106300 | None | code443 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800Kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 1504.64 | 1504.64 | 285.12 | False | None | None | False | None | False | 429002.9568 | 0 | 3091283 | 106300 | None | code444 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-do- 35 mm thick both side Commercial(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 4527.55 | 4527.55 | 54.72 | False | None | None | False | None | False | 247747.536 | 0 | 3091284 | 106300 | None | code445 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Cum | 134674.96 | 134674.96 | 1.58 | False | None | None | False | None | False | 212786.4368 | 0 | 3091285 | 106300 | None | code446 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | No | 1384.71 | 1384.71 | 15.0 | False | None | None | False | None | False | 20770.65 | 0 | 3091286 | 106300 | None | code447 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Handles 300mm(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | No | 749.6 | 749.6 | 30.0 | False | None | None | False | None | False | 22488.0 | 0 | 3091287 | 106300 | None | code448 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | No | 511.09 | 511.09 | 15.0 | False | None | None | False | None | False | 7666.35 | 0 | 3091288 | 106300 | None | code449 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | No | 204.44 | 204.44 | 27.0 | False | None | None | False | None | False | 5519.88 | 0 | 3091289 | 106300 | None | code450 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | No | 95.4 | 95.4 | 49.0 | False | None | None | False | None | False | 4674.6 | 0 | 3091290 | 106300 | None | code451 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | No | 136.29 | 136.29 | 15.0 | False | None | None | False | None | False | 2044.35 | 0 | 3091291 | 106300 | None | code452 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | No | 1433.77 | 1433.77 | 15.0 | False | None | None | False | None | False | 21506.55 | 0 | 3091292 | 106300 | None | code453 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | No | 81.77 | 81.77 | 90.0 | False | None | None | False | None | False | 7359.3 | 0 | 3091293 | 106300 | None | code454 | Providing & Fixing of corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications.(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Rmtr | 15.0 | 15.0 | 94.8 | False | None | None | False | None | False | 1422.0 | 0 | 3091294 | 106300 | None | code455 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall
be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 9177.77 | 9177.77 | 89.4 | False | None | None | False | None | False | 820492.638 | 0 | 3091295 | 106300 | None | code456 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 7794.43 | 7794.43 | 9.54 | False | None | None | False | None | False | 74358.8622 | 0 | 3091296 | 106300 | None | code457 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Kg | 228.97 | 228.97 | 4062.24 | False | None | None | False | None | False | 930131.0928 | 0 | 3091297 | 106300 | None | code458 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 Kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately)Size 62 x 100mm(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | m | 956.76 | 956.76 | 132.0 | False | None | None | False | None | False | 126292.32 | 0 | 3091298 | 106300 | None | code459 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 Kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 4749.71 | 4749.71 | 41.58 | False | None | None | False | None | False | 197492.9418 | 0 | 3091299 | 106300 | None | code460 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 Kg and door width upto 700 mm), with necessary accessories and screws etc. complete.(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | No | 1518.27 | 1518.27 | 25.0 | False | None | None | False | None | False | 37956.75 | 0 | 3091300 | 106300 | None | code461 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside)(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 425.22 | 425.22 | 2278.45 | False | None | None | False | None | False | 968842.509 | 0 | 3091301 | 106300 | None | code462 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 287.57 | 287.57 | 2450.47 | False | None | None | False | None | False | 704681.6579 | 0 | 3091302 | 106300 | None | code463 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 136.29 | 136.29 | 4728.9 | False | None | None | False | None | False | 644501.781 | 0 | 3091303 | 106300 | None | code464 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside)(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 475.65 | 475.65 | 1403.55 | False | None | None | False | None | False | 667598.5575 | 0 | 3091304 | 106300 | None | code465 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge.(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 482.47 | 482.47 | 94.85 | False | None | None | False | None | False | 45762.2795 | 0 | 3091305 | 106300 | None | code466 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Rmtr | 51.79 | 51.79 | 4200.0 | False | None | None | False | None | False | 217518.0 | 0 | 3091306 | 106300 | None | code467 | Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer.(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 283.2 | 283.2 | 50.0 | False | None | None | False | None | False | 14160.0 | 0 | 3091307 | 106300 | None | code468 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Rmtr | 70.87 | 70.87 | 719.8 | False | None | None | False | None | False | 51012.226 | 0 | 3091308 | 106300 | None | code469 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 Kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 1601.41 | 1601.41 | 816.68 | False | None | None | False | None | False | 1307839.5188 | 0 | 3091309 | 106300 | None | code470 | Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 1807.21 | 1807.21 | 281.28 | False | None | None | False | None | False | 508332.0288 | 0 | 3091310 | 106300 | None | code471 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 7261.53 | 7261.53 | 163.75 | False | None | None | False | None | False | 1189075.5375 | 0 | 3091311 | 106300 | None | code472 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 402.06 | 402.06 | 664.5 | False | None | None | False | None | False | 267168.87 | 0 | 3091312 | 106300 | None | code473 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 Kg/bag of cement. (For calculation purpose 320 Kg of Cement for M-20 grade of Concrete is considered in the analysis)(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 838.18 | 838.18 | 136.88 | False | None | None | False | None | False | 114730.0784 | 0 | 3091313 | 106300 | None | code474 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Cum | 2748.97 | 2748.97 | 25.13 | False | None | None | False | None | False | 69081.6161 | 0 | 3091314 | 106300 | None | code475 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 Kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 1211.62 | 1211.62 | 83.78 | False | None | None | False | None | False | 101509.5236 | 0 | 3091315 | 106300 | None | code476 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 1974.84 | 1974.84 | 383.22 | False | None | None | False | None | False | 756798.1848 | 0 | 3091316 | 106300 | None | code477 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Kg | 770.04 | 770.04 | 352.8 | False | None | None | False | None | False | 271670.112 | 0 | 3091317 | 106300 | None | code478 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 173.09 | 173.09 | 4728.92 | False | None | None | False | None | False | 818528.7628 | 0 | 3091318 | 106300 | None | code479 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 Sqm. Over and including priming coat of exterior primer applied @ 0.90 L/10 Sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 212.61 | 212.61 | 1403.55 | False | None | None | False | None | False | 298408.7655 | 0 | 3091319 | 106300 | None | code480 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 68.15 | 68.15 | 103.35 | False | None | None | False | None | False | 7043.3025 | 0 | 3091320 | 106300 | None | code481 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 156.73 | 156.73 | 103.35 | False | None | None | False | None | False | 16198.0455 | 0 | 3091321 | 106300 | None | code482 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 72.23 | 72.23 | 131.33 | False | None | None | False | None | False | 9485.9659 | 0 | 3091322 | 106300 | None | code483 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.
3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.)(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 922.68 | 922.68 | 131.33 | False | None | None | False | None | False | 121175.5644 | 0 | 3091323 | 106300 | None | code484 | Providing and supplying aluminium extruded tubular and other alu- minium sections as per the architectural drawings and approved draw- ings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment.(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Kg | 554.7 | 554.7 | 2053.35 | False | None | None | False | None | False | 1138993.245 | 0 | 3091324 | 106300 | None | code485 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2)For payment, only the actual area of glass on face 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/ m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 4147.3 | 4147.3 | 234.0 | False | None | None | False | None | False | 970468.2 | 0 | 3091325 | 106300 | None | code486 | Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge.(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 5666.94 | 5666.94 | 93.6 | False | None | None | False | None | False | 530425.584 | 0 | 3091326 | 106300 | None | code487 | Providing and fixing in position 12mm thick plaster of paris (Gypsum anhydrous) for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications.(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 1736.33 | 1736.33 | 326.67 | False | None | None | False | None | False | 567206.9211 | 0 | 3091327 | 106300 | None | code488 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per m2 including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge.(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 2307.39 | 2307.39 | 490.01 | False | None | None | False | None | False | 1130644.1739 | 0 | 3091328 | 106300 | None | code489 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 5459.78 | 5459.78 | 180.29 | False | None | None | False | None | False | 984343.7362 | 0 | 3091329 | 106300 | None | code490 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in- charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials, labour, usage charges of machinery complete as per specifications.(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Kg | 616.03 | 616.03 | 360.0 | False | None | None | False | None | False | 221770.8 | 0 | 3091330 | 106300 | None | code491 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10Kg/ Sqm) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 1346.55 | 1346.55 | 36.0 | False | None | None | False | None | False | 48475.8 | 0 | 3091331 | 106300 | None | code492 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800Kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 1630.03 | 1630.03 | 617.27 | False | None | None | False | None | False | 1006168.6181 | 0 | 3091332 | 106300 | None | code493 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge.(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 6103.07 | 6103.07 | 4.41 | False | None | None | False | None | False | 26914.5387 | 0 | 3091333 | 106300 | None | code494 | Roof Water Proofing. Surface Preparation: remove all surface laitance and contamination free from loose aggregate or other sharp protrusions with fairly smooth finish by wire brush and grinding method and surface shall be DRY for application of single component pitch modified polyurethane cures by reaction with atmospheric moisture to given a tough elastomeric waterproof membrane.
System : Provide and applying 1.2 mm thick roller applied single component bitumen modified polyurathene coating NITPROOF 600 or equivalent, having elongation capacity of 450 % as per ASTM D412, having Tensile strength 1.5 n/mm2 as per ASTM D 412, Tear resistance of 15 N as per ASTM D 624 and having shore A Hardness 50 as per ASTM D 2240. Waterproofing treatment to be provided after proper surface preparation as per Manufacture Specification.
Protection of waterproofing system with minimum 50 mm thick screed and providing construction joints and sealing the same with PU sealant.TERRACE FLOOR
(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 1593.0 | 1593.0 | 2161.0 | False | None | None | False | None | False | 3442473.0 | 0 | 3091334 | 106300 | None | code495 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 Kg/sqcm & class 3(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | m | 560.15 | 560.15 | 240.0 | False | None | None | False | None | False | 134436.0 | 0 | 3091335 | 106300 | None | code496 | supports of same angle iron etc. as directed, including hand railing on both sides with 25mm dia. GI pipes with angle iron props at 2 Mtr. intervals and 0.5M heigh, including fixing in ground with CC 1:2:4 and two coats of anticorrosive bituminous paint etc. with all lead and lifts etc. complete with:: MS angle of 65 x 65 x 10mm(FIFTH FLOOR & TERRACE FLOOR) ---- etc., complete with all lead | m | 6543.28 | 6543.28 | 13.2 | False | None | None | False | None | False | 86371.296 | 0 | 3091336 | 106300 | None | code497 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.COLUMNS(TERRACE FLOOR) ---- etc., complete with all lead | Cum | 16005.75 | 16005.75 | 34.7 | False | None | None | False | None | False | 555399.525 | 0 | 3091337 | 106300 | None | code498 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork-LIFT CORE WALL(TERRACE FLOOR) ---- etc., complete with all lead | Cum | 16005.75 | 16005.75 | 7.2 | False | None | None | False | None | False | 115241.4 | 0 | 3091338 | 106300 | None | code499 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork-ROOF BEAM. (TERRACE FLOOR) ---- etc., complete with all lead | Cum | 15064.23 | 15064.23 | 37.38 | False | None | None | False | None | False | 563100.9174 | 0 | 3091339 | 106300 | None | code500 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. RCC SLAB(TERRACE FLOOR) ---- etc., complete with all lead | Cum | 14122.72 | 14122.72 | 48.45 | False | None | None | False | None | False | 684245.784 | 0 | 3091340 | 106300 | None | code501 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.RCC STAIRCASE(TERRACE FLOOR) ---- etc., complete with all lead | Cum | 13651.96 | 13651.96 | 8.34 | False | None | None | False | None | False | 113857.3464 | 0 | 3091341 | 106300 | None | code502 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.LINTELS(TERRACE FLOOR) ---- etc., complete with all lead | Cum | 15064.23 | 15064.23 | 2.58 | False | None | None | False | None | False | 38865.7134 | 0 | 3091342 | 106300 | None | code503 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork- CILL/CHEJJA(TERRACE FLOOR) ---- etc., complete with all lead | Cum | 13227.02 | 13227.02 | 4.01 | False | None | None | False | None | False | 53040.3502 | 0 | 3091343 | 106300 | None | code504 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.(TERRACE FLOOR) ---- etc., complete with all lead | Tonne | 123082.1 | 123082.1 | 24.27 | False | None | None | False | None | False | 2987202.567 | 0 | 3091344 | 106300 | None | code505 | Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications.(TERRACE FLOOR) ---- etc., complete with all lead | Rmtr | 38.94 | 38.94 | 89.6 | False | None | None | False | None | False | 3489.024 | 0 | 3091345 | 106300 | None | code506 | Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge.(TERRACE FLOOR) ---- etc., complete with all lead | Rmtr | 86.14 | 86.14 | 89.6 | False | None | None | False | None | False | 7718.144 | 0 | 3091346 | 106300 | None | code507 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800Kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 1802.4 | 1802.4 | 570.03 | False | None | None | False | None | False | 1027422.072 | 0 | 3091347 | 106300 | None | code508 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800Kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 1518.97 | 1518.97 | 99.84 | False | None | None | False | None | False | 151653.9648 | 0 | 3091348 | 106300 | None | code509 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-do- 35 mm thick both side Commercial(TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 4570.67 | 4570.67 | 20.16 | False | None | None | False | None | False | 92144.7072 | 0 | 3091349 | 106300 | None | code510 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.(TERRACE FLOOR) ---- etc., complete with all lead | Cum | 135957.58 | 135957.58 | 0.75 | False | None | None | False | None | False | 101968.185 | 0 | 3091350 | 106300 | None | code511 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.(TERRACE FLOOR) ---- etc., complete with all lead | No | 1397.89 | 1397.89 | 5.0 | False | None | None | False | None | False | 6989.45 | 0 | 3091351 | 106300 | None | code512 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Handles 300mm(TERRACE FLOOR) ---- etc., complete with all lead | No | 756.73 | 756.73 | 10.0 | False | None | None | False | None | False | 7567.3 | 0 | 3091352 | 106300 | None | code513 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm(TERRACE FLOOR) ---- etc., complete with all lead | No | 515.96 | 515.96 | 5.0 | False | None | None | False | None | False | 2579.8 | 0 | 3091353 | 106300 | None | code514 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm(TERRACE FLOOR) ---- etc., complete with all lead | No | 206.38 | 206.38 | 9.0 | False | None | None | False | None | False | 1857.42 | 0 | 3091354 | 106300 | None | code515 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm(TERRACE FLOOR) ---- etc., complete with all lead | No | 96.31 | 96.31 | 15.0 | False | None | None | False | None | False | 1444.65 | 0 | 3091355 | 106300 | None | code516 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm(TERRACE FLOOR) ---- etc., complete with all lead | No | 137.59 | 137.59 | 4.0 | False | None | None | False | None | False | 550.36 | 0 | 3091356 | 106300 | None | code517 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.(TERRACE FLOOR) ---- etc., complete with all lead | No | 1447.43 | 1447.43 | 5.0 | False | None | None | False | None | False | 7237.15 | 0 | 3091357 | 106300 | None | code518 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm(TERRACE FLOOR) ---- etc., complete with all lead | No | 82.55 | 82.55 | 30.0 | False | None | None | False | None | False | 2476.5 | 0 | 3091358 | 106300 | None | code519 | Providing & Fixing of corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications.(TERRACE FLOOR) ---- etc., complete with all lead | Rmtr | 15.0 | 15.0 | 32.4 | False | None | None | False | None | False | 486.0 | 0 | 3091359 | 106300 | None | code520 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall
be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)(TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 9265.18 | 9265.18 | 53.4 | False | None | None | False | None | False | 494760.612 | 0 | 3091360 | 106300 | None | code521 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 7868.66 | 7868.66 | 3.6 | False | None | None | False | None | False | 28327.176 | 0 | 3091361 | 106300 | None | code522 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding(TERRACE FLOOR) ---- etc., complete with all lead | Kg | 231.15 | 231.15 | 1197.0 | False | None | None | False | None | False | 276686.55 | 0 | 3091362 | 106300 | None | code523 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 Kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately)Size 62 x 100mm(TERRACE FLOOR) ---- etc., complete with all lead | m | 965.87 | 965.87 | 24.0 | False | None | None | False | None | False | 23180.88 | 0 | 3091363 | 106300 | None | code524 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 Kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness(TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 4794.94 | 4794.94 | 7.56 | False | None | None | False | None | False | 36249.7464 | 0 | 3091364 | 106300 | None | code525 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 Kg and door width upto 700 mm), with necessary accessories and screws etc. complete.(TERRACE FLOOR) ---- etc., complete with all lead | No | 1532.73 | 1532.73 | 15.0 | False | None | None | False | None | False | 22990.95 | 0 | 3091365 | 106300 | None | code526 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside)(TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 429.27 | 429.27 | 528.42 | False | None | None | False | None | False | 226834.8534 | 0 | 3091366 | 106300 | None | code527 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 290.31 | 290.31 | 651.26 | False | None | None | False | None | False | 189067.2906 | 0 | 3091367 | 106300 | None | code528 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 137.59 | 137.59 | 1179.68 | False | None | None | False | None | False | 162312.1712 | 0 | 3091368 | 106300 | None | code529 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside)(TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 480.18 | 480.18 | 477.6 | False | None | None | False | None | False | 229333.968 | 0 | 3091369 | 106300 | None | code530 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge.(TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 487.06 | 487.06 | 46.8 | False | None | None | False | None | False | 22794.408 | 0 | 3091370 | 106300 | None | code531 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide(TERRACE FLOOR) ---- etc., complete with all lead | Rmtr | 52.28 | 52.28 | 4200.0 | False | None | None | False | None | False | 219576.0 | 0 | 3091371 | 106300 | None | code532 | Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer.(TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 283.2 | 283.2 | 50.0 | False | None | None | False | None | False | 14160.0 | 0 | 3091372 | 106300 | None | code533 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.(TERRACE FLOOR) ---- etc., complete with all lead | Rmtr | 71.55 | 71.55 | 578.8 | False | None | None | False | None | False | 41413.14 | 0 | 3091373 | 106300 | None | code534 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 Kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm(TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 1616.66 | 1616.66 | 104.6 | False | None | None | False | None | False | 169102.636 | 0 | 3091374 | 106300 | None | code535 | Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm(TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 1824.42 | 1824.42 | 147.6 | False | None | None | False | None | False | 269284.392 | 0 | 3091375 | 106300 | None | code536 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.(TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 7330.69 | 7330.69 | 79.85 | False | None | None | False | None | False | 585355.5965 | 0 | 3091376 | 106300 | None | code537 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 405.88 | 405.88 | 244.68 | False | None | None | False | None | False | 99310.7184 | 0 | 3091377 | 106300 | None | code538 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 Kg/bag of cement. (For calculation purpose 320 Kg of Cement for M-20 grade of Concrete is considered in the analysis)(TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 846.17 | 846.17 | 37.24 | False | None | None | False | None | False | 31511.3708 | 0 | 3091378 | 106300 | None | code539 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.(TERRACE FLOOR) ---- etc., complete with all lead | Cum | 2775.15 | 2775.15 | 7.25 | False | None | None | False | None | False | 20119.8375 | 0 | 3091379 | 106300 | None | code540 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 Kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.(TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 1223.16 | 1223.16 | 24.16 | False | None | None | False | None | False | 29551.5456 | 0 | 3091380 | 106300 | None | code541 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.(TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 1993.65 | 1993.65 | 97.08 | False | None | None | False | None | False | 193543.542 | 0 | 3091381 | 106300 | None | code542 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(TERRACE FLOOR) ---- etc., complete with all lead | Kg | 777.37 | 777.37 | 176.4 | False | None | None | False | None | False | 137128.068 | 0 | 3091382 | 106300 | None | code543 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 174.74 | 174.74 | 1179.68 | False | None | None | False | None | False | 206137.2832 | 0 | 3091383 | 106300 | None | code544 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 Sqm. Over and including priming coat of exterior primer applied @ 0.90 L/10 Sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 214.64 | 214.64 | 477.6 | False | None | None | False | None | False | 102512.064 | 0 | 3091384 | 106300 | None | code545 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 68.79 | 68.79 | 57.0 | False | None | None | False | None | False | 3921.03 | 0 | 3091385 | 106300 | None | code546 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 158.23 | 158.23 | 57.0 | False | None | None | False | None | False | 9019.11 | 0 | 3091386 | 106300 | None | code547 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 72.92 | 72.92 | 48.38 | False | None | None | False | None | False | 3527.8696 | 0 | 3091387 | 106300 | None | code548 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.
3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.)(TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 931.47 | 931.47 | 48.38 | False | None | None | False | None | False | 45064.5186 | 0 | 3091388 | 106300 | None | code549 | Providing and supplying aluminium extruded tubular and other alu- minium sections as per the architectural drawings and approved draw- ings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment.(TERRACE FLOOR) ---- etc., complete with all lead | Kg | 559.98 | 559.98 | 780.0 | False | None | None | False | None | False | 436784.4 | 0 | 3091389 | 106300 | None | code550 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2)For payment, only the actual area of glass on face 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/ m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.(TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 4186.8 | 4186.8 | 120.0 | False | None | None | False | None | False | 502416.0 | 0 | 3091390 | 106300 | None | code551 | Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge.(TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 5720.91 | 5720.91 | 48.0 | False | None | None | False | None | False | 274603.68 | 0 | 3091391 | 106300 | None | code552 | Providing and fixing in position 12mm thick plaster of paris (Gypsum anhydrous) for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications.(TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 1752.87 | 1752.87 | 41.84 | False | None | None | False | None | False | 73340.0808 | 0 | 3091392 | 106300 | None | code553 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per m2 including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge.(TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 2329.36 | 2329.36 | 62.76 | False | None | None | False | None | False | 146190.6336 | 0 | 3091393 | 106300 | None | code554 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2(TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 5511.78 | 5511.78 | 166.78 | False | None | None | False | None | False | 919254.6684 | 0 | 3091394 | 106300 | None | code555 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 Kg/sqcm & class 3(TERRACE FLOOR) ---- etc., complete with all lead | m | 565.49 | 565.49 | 180.0 | False | None | None | False | None | False | 101788.2 | 0 | 3091395 | 106300 | None | code556 | supports of same angle iron etc. as directed, including hand railing on both sides with 25mm dia. GI pipes with angle iron props at 2 Mtr. intervals and 0.5M heigh, including fixing in ground with CC 1:2:4 and two coats of anticorrosive bituminous paint etc. with all lead and lifts etc. complete with:: MS angle of 65 x 65 x 10mm(TERRACE FLOOR) ---- etc., complete with all lead | m | 6605.6 | 6605.6 | 13.2 | False | None | None | False | None | False | 87193.92 | 0 | 3091396 | 106300 | None | code557 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(TERRACE FLOOR) ---- etc., complete with all lead | Kg | 202.25 | 202.25 | 22400.0 | False | None | None | False | None | False | 4530400.0 | 0 | 3091397 | 106300 | None | code558 | Providing,fabricating and fixing Profiled Poly Urethane insulated Roof(PUF Sheet) having modular density 40Kg/Sqm and size 1.06m width and 7.60m length sheets roof having external sheet of 0.5mm steel, bottom sheet of 0.40mm steel with powder coated finish. The precoated sheet shall be of minimum 240MPa steel conforming to IS 14246 : 1995 and shal have zinc coating with minimum 120gsm as per IS 277:1992,.The roofing system shall have suitable water proof over lapping arrangments and GRIHA ceritifed.The fasting shall be of self tapping screws of required length with PVC head along with washer pre-painted aluminium cap unit with build in seal arrangments. The entire roof shall be firmly fastened to the existng frame including all lead and lifts, loading & unloading ,usage charges of machinery and equipments, transportation charges,labour charges and all other incidental charges etc.,complete as per standard technical detailed specifications and as directed by the Engineer in charge of the work.30 mm thickness(TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 3024.18 | 3024.18 | 640.0 | False | None | None | False | None | False | 1935475.2 | 0 | 3091398 | 106300 | None | code559 | Roof Water Proofing. Surface Preparation: remove all surface laitance and contamination free from loose aggregate or other sharp protrusions with fairly smooth finish by wire brush and grinding method and surface shall be DRY for application of single component pitch modified polyurethane cures by reaction with atmospheric moisture to given a tough elastomeric waterproof membrane.
System : Provide and applying 1.2 mm thick roller applied single component bitumen modified polyurathene coating NITPROOF 600 or equivalent, having elongation capacity of 450 % as per ASTM D412, having Tensile strength 1.5 n/mm2 as per ASTM D 412, Tear resistance of 15 N as per ASTM D 624 and having shore A Hardness 50 as per ASTM D 2240. Waterproofing treatment to be provided after proper surface preparation as per Manufacture Specification.
Protection of waterproofing system with minimum 50 mm thick screed and providing construction joints and sealing the same with PU sealant.TERRACE FLOOR
(TERRACE FLOOR) ---- etc., complete with all lead | Sqm | 1593.0 | 1593.0 | 594.0 | False | None | None | False | None | False | 946242.0 | 0 | 3091399 | 106300 | None | code560 | OXYGEN MAIN MANIFOLD SYSTEM : 40 cylinder (20+20) Oxygen Manifold should be suitable to withstand a pressure of 140 Kg/Sq Cmand above along with high pressure copper annealed tail pipes with end Brass adapter suitable for Oxygen Cylinders and manifold. Top frame comprising high pressure copper pipes of size 12mm I.D x 1.5mm wall thick, with high pressure brass fittings made of high tensile brass and connections through non-return values; high pressure copper tail pipes, made of high pressure copper pipe of size 7mm I.D x 1.5mm wall thick. The design of middle and bottom frames should be provided to fit both round and flat bottom cylinders safely. The manifold should be tested (hydraulically) at 3500 psig. ---- etc., complete with all lead | Set | 224554.0 | 224554.0 | 1.0 | False | None | None | False | None | False | 224554.0 | 0 | 3091400 | 106300 | None | code561 | Micro process based Automatic High flow Upto 2200 ltrs/min Oxygen Control Panel. Fully automatic changeover panel 3 SOURCE FULLY AUTOMATIC OXYGEN CONTROL PANEL Working Pressure from the oxygen concentrator plant 4.1 Kg/Sq Cm (Future Provision). Working Pressure from fully automatic control panel. 4.1 Kg/Sq Cm. Working Pressure from Emergency manifold system 4.1 Kg/Sq Cm. Changeover unit of all 3 sources should be at the pressure from oxygen concentrator plant Below 4.1Kg/Sq Cm. Changeover unit of all 3 sources should be at the pressure from main Manifold system Below 4.1Kg/Sq Cm.Changeover
unit of all 3 sources should be at the pressure from Emergency manifold system Below 4.1Kg/Sq Cm. The Control panel shall be of fully integrated type with all safety features inbuilt for high pressure and high flow Upto 2200 ltrs / min Oxygen system. All the electrical circuits should be operated at 12 volts & 24 volts with provision of inbuilt power conversion equipment. The Panel shall have the necessary instruments, gauges, LED Indicators etc. complete with separate indicators far from separate 3 sources. Pressure from oxygen concentrator plant Green signal for Normal pressure & Red signal for Low pressure. Pressure for manifold system Green signal for Normal Pressure & Red signal for low pressure.Left bank Green signal for Normal Pressure & Red for Low pressure. In Right bank Green signal for Normal Pressure & Red for Low pressure.
In Emergency manifold Green signal for Normal Pressure & Red for Low pressure. Main Line Green signal for Normal Pressure & Red for Low pressure ---- etc., complete with all lead | Nos | 217120.0 | 217120.0 | 1.0 | False | None | None | False | None | False | 217120.0 | 0 | 3091401 | 106300 | None | code562 | OXYGEN MANIFOLD SYSTEM EMERGENY The Control pannel shall be of fully integrated type with all saftety futures inbuilt for high pressure and high flow upto 2200 ltrs / min Oxygen system. 4+4 Cylinder Oxygen Manifold Should be suitable be withstand a pressure of 140 Kg/Sq Cmand above, along with high pressure copper annealed tail pipes with end Brass adapter suitable for Oxygen Cylinders and manifold. Top frame comprising of high pressure copper pipes of size 12mmI.D x 1.5mm wall thick, with high pressure brass fittings made of high tensile brass and connections through non return values high pressure copper tail pipes, made of high pressure copper pipe of size 7mm I.D x 1.5mm wall thick and a single state high pressure high flow regulator connected to a high pressure brass block. The design of middle and bottom frames should be provided to fit both round and flat bottom cylinders safely. The manifold should be tested (hydraulically) at 3500 psig and necessary test certificates should accompany along with the supply. SEMI AUTOMATIC EMERGENCY OXYGEN MANIFOLD CONTROL PANEL Semi automatic control panels designed for various control functions required during supply of oxygen through the manifold unit. Enclosed in a metal cabinet. This semi automatic control panel is highly efficient in triggering the signal for the Reserve system to go operational in case primary and secondary system fails in emergency. This panel is normally connected in a permanent mode and change over is semi automatic. Some of the features of this pannels are as follows Control panel shall be made of M.S.duly powder coated. Easy maintenance. Highly reliable. Designed for safety and continuity of flow supply at a constant pressure. ---- etc., complete with all lead | Set | 155760.0 | 155760.0 | 1.0 | False | None | None | False | None | False | 155760.0 | 0 | 3091402 | 106300 | None | code563 | OXYGEN MAIN MANIFOLD SYSTEM : 20 cylinder (10+10) Oxygen Manifold should be suitable to withstand a pressure of 140 Kg/Sq Cmand above along with high pressure copper annealed tail pipes with end Brass adapter suitable for Oxygen Cylinders and manifold. Top frame comprising high pressure copper pipes of size 12mm I.D x 1.5mm wall thick, with high pressure brass fittings made of high tensile brass and connections through non-return values; high pressure copper tail pipes, made of high pressure copper pipe of size 7mm I.D x 1.5mm wall thick. The design of middle and bottom frames should be provided to fit both round and flat bottom cylinders safely. The manifold should be tested (hydraulically) at 3500 psig. ---- etc., complete with all lead | Set | 128915.0 | 128915.0 | 1.0 | False | None | None | False | None | False | 128915.0 | 0 | 3091403 | 106300 | None | code564 | FULLY AUTOMATIC OXYGEN MANIFOLD CONTROL PANEL Supply, Installation, Testing and commissioning of Fully Automatic O2 Control Panel (1800-2000) lpm deliver capacity manifold control panel, control panel should have all necessary controls and safety fittings. complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead | Nos | 218300.0 | 218300.0 | 1.0 | False | None | None | False | None | False | 218300.0 | 0 | 3091404 | 106300 | None | code565 | NITROUS OXIDE MAIN MANIFOLD SYSTEM Supply, Installation, Testing and commissioning of 4 cylinder (2 + 2) Nitrous Oxide manifold supply with all necessary controls and safety fittings. Make of AKTIV or Equilaent Make complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.SEMI AUTOMATIC NITROUS OXIDE MAIN MANIFOLD CONTROL PANEL Supply, Installation, Testing and commissioning of 500 lpm deliver capacity manifold control panel, control panel should have all necessary controls and safety fittings. with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. Nitrous Oxide System ---- etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead | Set | 106790.0 | 106790.0 | 1.0 | False | None | None | False | None | False | 106790.0 | 0 | 3091405 | 106300 | None | code566 | NITROUS OXIDE EMERGENCY MANIFOLD SYSTEM Supply, Installation, Testing and commissioning of 2 cylinders Nitrous Oxide manifold supply with all necessary controls and safety fittings and 0 To 10 Kg/Sq Cm High Presuure Regulator complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead | Set | 69030.0 | 69030.0 | 1.0 | False | None | None | False | None | False | 69030.0 | 0 | 3091406 | 106300 | None | code567 | MEDICAL AND SURGICAL AIR SYSTEM.Compressed Air System: System For Medical use.Capacity of Piston Displacement : 52.7 cfm 1620 Lpm.Drive : Belt driven.No. of Air Compressors : 2 Nos. (1W + 1S by)Motor Capacity : 15 HP as requiredReceiver Capacity : 2000 liters water capacity After Reservoir shall have oil seperator and Moisture Receiver type : Automatic Vertical type with inlet, outlet & drain provisions ---- etc., complete with all lead | Set | 1770000.0 | 1770000.0 | 2.0 | False | None | None | False | None | False | 3540000.0 | 0 | 3091407 | 106300 | None | code568 | Duplex Medical Air Dryer System ( Breathing Air System) (2 Nos of 1 set) 100 CFM -Air Dryer Min Working Pressure should be 4 bar,Rated Inlet Pressure should be 7 bar Max Working Pressure should be 16 bar,Supply Voltage Should be 100-240 VAC, 50/60 Hz, 1 Ph.Rated Inlet temperature should be 38 deg C,Dryer capable to give should be 40 PDP,Purge Loss 15% Air quality As per NFPA 99,Dual System,Three stage filter (Dessicated drier),CO & Dew point level as per NFPA 99,Bacterial Penetration 0.00001%,Failure Indication,Purge Saving control Manual,No refrigerant used,Energy saving Dew point based dryer cycling. ---- etc., complete with all lead | Set | 118000.0 | 118000.0 | 1.0 | False | None | None | False | None | False | 118000.0 | 0 | 3091408 | 106300 | None | code569 | DUPLEX COMPRESSED AIR BREATHING FILTERATION SYSTEM-3 STAGE-The filters Shouldhave maximum contaminant removal efficiency with minimum pressure drop. The filtration system should conform to breathing air filtration as per ISO 8573 Ch I Standard. Total 3-stages of filters Shouldbe used as mentioned below:Stage 1: Oil aerosol contents removal up to 0.5 mg/cum. Stage 2: Oil aerosol contents removal up to 0.01 mg/cum.Stage 3: Oil content removal up to 0.003 mg/cum along with removal of oil vapor and hydrocarbon odor as per ISO 8573 Ch-I Standard. ---- etc., complete with all lead | Set | 70800.0 | 70800.0 | 1.0 | False | None | None | False | None | False | 70800.0 | 0 | 3091409 | 106300 | None | code570 | Air Cooler : Supply, Installation, Testing and Commissioning of 80 CFM Air cooler system, with 3 phase fan (High RPM Fan) suitable for 415 V, 3Phs 50 Hz ---- etc., complete with all lead | Set | 70800.0 | 70800.0 | 1.0 | False | None | None | False | None | False | 70800.0 | 0 | 3091410 | 106300 | None | code571 | VACCUM SUPPLY SYSTEM
The pump installation shall be Duplex system consisting of 2 Nos (1W+1S BY) identical Rotary Vane Type Pumps each of which shall be capable of independently producing designed systems flow rate.
The pump shall be clearly marked with its performance, both its free air displacement and its volumetric throughput. Each pump should have capacity of minimum 4928LPM (300m3/h) i.e., 176 CFM. Pump should be capable of providing a vacuum of not less than 650 mm Hg (87 kPa).
The driving motor shall directly drive the pump unit and it shall be manufactured in accordance with HTM 2022/HTM 02-01 / conforms to IEC Standards. Recommendations suitable for 415 voltes, 3 phase, 50 Hz power supply.Each pump shall have a built in non-return valve and pressure switch such that inadvertent reversal of the motor Should not pressurize the Reservoir or the distribution system protection.The control panel shall consist of three separate , The system should include vacuum storage reservoir tank, Rated for full vacuum services with the storage capacity of approx 3000Ltr (2Nos Receiver Tank) as per standard recommendation. It should be equipped with an vacuum gauge and provision for manual draining by pass valve. The inside of the tank should be coated with a two-component coating to provide a hard, durable lining for rust Compartments, two compartments shall hold the motor starters, MCBS ammeters, and hour’s run-meters, for each pump. The remaining compartment shall house the vacuum switches, status monitoring equipment, delay timer and necessary interlock, selector switch with automatic change over, etc., complete with internal wiring using copper conductors. Control Panel system should be front operable. ---- etc., complete with all lead | Set | 1593000.0 | 1593000.0 | 2.0 | False | None | None | False | None | False | 3186000.0 | 0 | 3091411 | 106300 | None | code572 | VACUUM BACTERIAL FILTERATION,
Suitable Medical Vacuum filters are used for removal of bacteria & other contamination from the suction side of vacuum pumps, preventing infection of pump and the atmosphere.
These elements shall be of pleated construction giving a high surface area and long operational life. The efficiency to exceed the 0.005% penetration specified in HTM2022 for infectious disease unit.- i.e. complete bacterial removal. Elements shall be fitted in an aluminum housing suitable for various capacities. These are to be internally protected against corrosion by an alocrom treatment. The inner & outer surfaces of the housing are epoxy coated. Complete assembly shall be fitted with a sterilisable drain flask with isolation valve for removal of liquid if any. Differential pressure indicators are to be provided to monitor the status of element. Basics Specifications are as given below. ---- etc., complete with all lead | Set | 165200.0 | 165200.0 | 2.0 | False | None | None | False | None | False | 330400.0 | 0 | 3091412 | 106300 | None | code573 | Copper Pipe 76mm. ODx1.5 mm.thick.PIPELINE DISTRIBUTION SYSTEMSupply, Installation, Testing and commissioning of copper pipe for medical gas services. Pipes shall be priced for all necessary supports, standard fittings. Make of MEX FLOW or Equilaent Make complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead | Mtr | 8189.2 | 8189.2 | 70.0 | False | None | None | False | None | False | 573244.0 | 0 | 3091413 | 106300 | None | code574 | Copper Pipe 54mm. ODx1.2 mm.thick.PIPELINE DISTRIBUTION SYSTEMSupply, Installation, Testing and commissioning of copper pipe for medical gas services. Pipes shall be priced for all necessary supports, standard fittings. Make of MEX FLOW or Equilaent Make complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead | Mtr | 4854.52 | 4854.52 | 100.0 | False | None | None | False | None | False | 485452.0 | 0 | 3091414 | 106300 | None | code575 | Copper Pipe 42mm. ODx1.2 mm.thick.PIPELINE DISTRIBUTION SYSTEMSupply, Installation, Testing and commissioning of copper pipe for medical gas services. Pipes shall be priced for all necessary supports, standard fittings. Make of MEX FLOW or Equilaent Make complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead | Mtr | 3608.44 | 3608.44 | 270.0 | False | None | None | False | None | False | 974278.8 | 0 | 3091415 | 106300 | None | code576 | Copper Pipe 35mm. ODx1.2 mm.thick.PIPELINE DISTRIBUTION SYSTEMSupply, Installation, Testing and commissioning of copper pipe for medical gas services. Pipes shall be priced for all necessary supports, standard fittings. Make of MEX FLOW or Equilaent Make complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead | Mtr | 2570.04 | 2570.04 | 460.0 | False | None | None | False | None | False | 1182218.4 | 0 | 3091416 | 106300 | None | code577 | Copper Pipe 28mm. ODx0.9 mm.thick.PIPELINE DISTRIBUTION SYSTEMSupply, Installation, Testing and commissioning of copper pipe for medical gas services. Pipes shall be priced for all necessary supports, standard fittings. Make of MEX FLOW or Equilaent Make complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead | Mtr | 1492.7 | 1492.7 | 790.0 | False | None | None | False | None | False | 1179233.0 | 0 | 3091417 | 106300 | None | code578 | Copper Pipe 22mm. ODx0.9 mm.thick.PIPELINE DISTRIBUTION SYSTEMSupply, Installation, Testing and commissioning of copper pipe for medical gas services. Pipes shall be priced for all necessary supports, standard fittings. Make of MEX FLOW or Equilaent Make complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead | Mtr | 1156.4 | 1156.4 | 2490.0 | False | None | None | False | None | False | 2879436.0 | 0 | 3091418 | 106300 | None | code579 | Copper Pipe 15mm. ODx0.9 mm.thick.PIPELINE DISTRIBUTION SYSTEMSupply, Installation, Testing and commissioning of copper pipe for medical gas services. Pipes shall be priced for all necessary supports, standard fittings. Make of MEX FLOW or Equilaent Make complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead | Mtr | 949.9 | 949.9 | 4180.0 | False | None | None | False | None | False | 3970582.0 | 0 | 3091419 | 106300 | None | code580 | Copper Pipe 12mm. ODx0.7 mm.thick.PIPELINE DISTRIBUTION SYSTEMSupply, Installation, Testing and commissioning of copper pipe for medical gas services. Pipes shall be priced for all necessary supports, standard fittings. Make of MEX FLOW or Equilaent Make complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead | Mtr | 651.36 | 651.36 | 1540.0 | False | None | None | False | None | False | 1003094.4 | 0 | 3091420 | 106300 | None | code581 | Oxygen Outlets - drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes) ---- etc., complete with all lead | Nos | 3392.5 | 3392.5 | 394.0 | False | None | None | False | None | False | 1336645.0 | 0 | 3091421 | 106300 | None | code582 | Vacuum Outlets - drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes) ---- etc., complete with all lead | Nos | 3392.5 | 3392.5 | 286.0 | False | None | None | False | None | False | 970255.0 | 0 | 3091422 | 106300 | None | code583 | Compressed Air Outlets 4 Bar - drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes) ---- etc., complete with all lead | Nos | 3392.5 | 3392.5 | 286.0 | False | None | None | False | None | False | 970255.0 | 0 | 3091423 | 106300 | None | code584 | Compressed Air Outlets 7 Bar- drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes) ---- etc., complete with all lead | Nos | 3392.5 | 3392.5 | 13.0 | False | None | None | False | None | False | 44102.5 | 0 | 3091424 | 106300 | None | code585 | Nitrous Oxide Outlets - drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes) ---- etc., complete with all lead | Nos | 3392.5 | 3392.5 | 13.0 | False | None | None | False | None | False | 44102.5 | 0 | 3091425 | 106300 | None | code586 | ACCESSORIES ALONG WITH CALIBRATION CERTIFICATES. Oxygen Flow meter with Humidifier Bottle, Flow meter should be Backpressure Compensated, Flow meter should be accurate gas flow measurement and control within a range of 0-15 liters per minute, It should meet strict precision and durability standards, Flow meter body should be made of brass material, Flow tube and shroud components should be made of clear, impact resistant polycarbonate, The humidifier bottle should be unbreakable polycarbonate material and autoclavable at 134 degrees centigrade.The humidifier should have built in safety valve.With Calibration Certificates ---- etc., complete with all lead | Nos | 2849.7 | 2849.7 | 285.0 | False | None | None | False | None | False | 812164.5 | 0 | 3091426 | 106300 | None | code587 | Single piece wall mounted suction collection & regulation unit. With jar capacity of 600ml each shall be provided at each of the bed side. Jars are should be made of autoclavable materials. The units shall be clamped to the wall using suitable clamps.With Calibration Certificate’s. ---- etc., complete with all lead | Nos | 3528.2 | 3528.2 | 273.0 | False | None | None | False | None | False | 963198.6 | 0 | 3091427 | 106300 | None | code588 | Theatre Vacuum Unit, The unit should comprise of two reusable 2000 ml shatter resistant bottle, each made up of poly carbonate material and fully auto cleavable at 134 degree centigrade. Should have a vacuum regulator with instant ON / OFF switch a three way selector switch with an option to operate either.- Left, Right or BothAll the above items Should be mounted on a Trolley having a free moving castor wheels. ---- etc., complete with all lead | Nos | 14750.0 | 14750.0 | 6.0 | False | None | None | False | None | False | 88500.0 | 0 | 3091428 | 106300 | None | code589 | Isolation Valves 76 mm .ISOLATION VALVES:-Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction ---- etc., complete with all lead | Nos | 11540.4 | 11540.4 | 2.0 | False | None | None | False | None | False | 23080.8 | 0 | 3091429 | 106300 | None | code590 | Isolation Valves 54 mm.ISOLATION VALVES:-Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction ---- etc., complete with all lead | Nos | 8826.4 | 8826.4 | 5.0 | False | None | None | False | None | False | 44132.0 | 0 | 3091430 | 106300 | None | code591 | Isolation Valves 42 mm.ISOLATION VALVES:-Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction ---- etc., complete with all lead | Nos | 8142.0 | 8142.0 | 10.0 | False | None | None | False | None | False | 81420.0 | 0 | 3091431 | 106300 | None | code592 | Isolation Valves 35 mm .ISOLATION VALVES:-Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction ---- etc., complete with all lead | Nos | 5428.0 | 5428.0 | 11.0 | False | None | None | False | None | False | 59708.0 | 0 | 3091432 | 106300 | None | code593 | Isolation Valves 28 mm .ISOLATION VALVES:-Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction ---- etc., complete with all lead | Nos | 4071.0 | 4071.0 | 15.0 | False | None | None | False | None | False | 61065.0 | 0 | 3091433 | 106300 | None | code594 | Isolation Valves 22 mm .ISOLATION VALVES:-Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction ---- etc., complete with all lead | Nos | 3392.5 | 3392.5 | 20.0 | False | None | None | False | None | False | 67850.0 | 0 | 3091434 | 106300 | None | code595 | Isolation Valves 15 mm .ISOLATION VALVES:-Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction ---- etc., complete with all lead | Nos | 2714.0 | 2714.0 | 118.0 | False | None | None | False | None | False | 320252.0 | 0 | 3091435 | 106300 | None | code596 | Zonal Valve box five Gas services An Zonal area valve box should have bellow spec. Wall mounted M.S. box with powder coated & lockable, Front glass mounting easily visible & using imported brass body quarter turn ball valves using for opening & closing position.The valve box door cannot be close during valve close position. ---- etc., complete with all lead | Nos | 23364.0 | 23364.0 | 6.0 | False | None | None | False | None | False | 140184.0 | 0 | 3091436 | 106300 | None | code597 | Zonal Valve box three Gas services An Zonal area valve box should have bellow spec. Wall mounted M.S. box with powder coated & lockable, Front glass mounting easily visible & using imported brass body quarter turn ball valves using for opening & closing position.The valve box door cannot be close during valve close position. ---- etc., complete with all lead | Nos | 18319.5 | 18319.5 | 18.0 | False | None | None | False | None | False | 329751.0 | 0 | 3091437 | 106300 | None | code598 | Digital Area Alarm for five Gas Systems.Micro processor controlled Area Gas alarm panel five Lines, Should audio- visual alarms for each gas used on the floor and come fitted with test and mute button. Running on electricity 220V, these units are suggested to be fitted on each floor as well as areas of heavy usage. It should be fitted with a digital pressure gauge. It indicates low, medium & high pressure sensors. ---- etc., complete with all lead | Nos | 41300.0 | 41300.0 | 6.0 | False | None | None | False | None | False | 247800.0 | 0 | 3091438 | 106300 | None | code599 | Digital Area Alarm for Three Gas Systems.Micro processor controlled Area Gas alarm panel five Lines, Should audio- visual alarms for each gas used on the floor and come fitted with test and mute button. Running on electricity 220V, these units are suggested to be fitted on each floor as well as areas of heavy usage. It should be fitted with a digital pressure gauge. It indicates low, medium & high pressure sensors. ---- etc., complete with all lead | Nos | 34220.0 | 34220.0 | 18.0 | False | None | None | False | None | False | 615960.0 | 0 | 3091439 | 106300 | None | code600 | Bed Head Panel and Railing. 1.5meter
Double railing Bed headed panels should have below Specifications.
Accessories 1. IV Stand extendable type with aluminium slider. 2. Monitor stand wall panel mounted. 3. Ward vaccum unit slider. 4. 3/6W LED light fixture. 5. Two duplex 230 V,6/16 Amp 6 nos of 6 amps sockets with control switches Electrical Sockets.
Provision Medical Gas Terminal Units as follows. 2.1 Two oxygen outlet.
2.2 One Vacuum outlet. 2.3 One compressed Air outlet 4 Bar. ---- etc., complete with all lead | Nos | 31860.0 | 31860.0 | 96.0 | False | None | None | False | None | False | 3058560.0 | 0 | 3091440 | 106300 | None | code601 | Surgeon Single Arm Pendant: The material of the Pendent should be Single-armed rotary ceiling mounted surgical Pendent High-strength aluminum alloy. Extension arm 700mm.Loading capacity: 70-150Kg.Level degrees rotation:340n.w.:158Kg.Should be provision for Gas outlets Oxygen 02 nos, Vaccum 02 nos,Air 4 Bar 01 nos,Air 7 Bar 01 nos, Nitrous Oxide01 nos,Power socket 08 nos,Grounding terminal 01 nos,Platform 03 nos, IV pole 01 nos,Drawer 01 nos. ---- etc., complete with all lead | Nos | 230100.0 | 230100.0 | 6.0 | False | None | None | False | None | False | 1380600.0 | 0 | 3091441 | 106300 | None | code602 | Anaesthesia Single Arm Pendant: The material of the Pendent should be Single-armed rotary ceiling mounted surgical Pendent High-strength aluminum alloy. Extension arm 700mm.Loading capacity: 70-150Kg.Level degrees rotation:340n.w.:158Kg.Should be provision for Gas outlets Oxygen 02 nos, Vaccum 02 nos,Air 4 Bar 01 nos,Air 7 Bar 01 nos, Nitrous Oxide01 nos,Power socket 08 nos,Grounding terminal 01 nos,Platform 03 nos, IV pole 01 nos,Drawer 01 nos. ---- etc., complete with all lead | Nos | 230100.0 | 230100.0 | 6.0 | False | None | None | False | None | False | 1380600.0 | 0 | 3091442 | 106300 | None | code603 | Conversion Kit for Anesthesia for Oxygen. Should have high pressure antistatic tubing which is color coded. ---- etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead | Nos | 1652.0 | 1652.0 | 6.0 | False | None | None | False | None | False | 9912.0 | 0 | 3091443 | 106300 | None | code604 | Conversion Kit for Anesthesia for Nitrous Oxide. Should have high pressure antistatic tubing which is color coded. ---- etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead | Nos | 1652.0 | 1652.0 | 6.0 | False | None | None | False | None | False | 9912.0 | 0 | 3091444 | 106300 | None | code605 | WALL PANELING : shall be made up of 19mm thick BWR boarer free ISI marked ply frame work. The framing shall be fixed at intervals of 2 0 c/c. the framing shall be fixed with 12mm thick ply and 6mm ply as to form grooves finished 1mm thick laminate of approved color with 1mm groove forming 1 6 -2 panels, 1/2 x 1/2 teak/beech wood beading shall be fixed on all the corners as to form a design and shall be polished. (GROUND + 1ST + 2ND + 3RD + 4TH + 5TH FLOOR) ---- etc., complete with all lead | Sqm | 3033.78 | 3033.78 | 727.6 | False | None | None | False | None | False | 2207378.328 | 0 | 3091445 | 106300 | None | code606 | CHAIRS : Supplying Medium BACK Chair Blue mango with contact crome flex back chair with co-active synchro, gas lift, revolving, tilting, and height adjustable fully cushioned medium back chairs and two way adjustable arms. prior confirmation shall be obtain from the officer / Architect for approval. (GROUND + 1ST + 2ND + 3RD + 4TH + 5TH FLOOR) ---- etc., complete with all lead | No | 5310.0 | 5310.0 | 70.0 | False | None | None | False | None | False | 371700.0 | 0 | 3091446 | 106300 | None | code607 | STAFF CHAIRS : Supplying HIGH BACK Chair Blue mango with contact crome flex back chair with co-active synchro, gas lift, revolving, tilting, and height adjustable fully cushioned medium back chairs and two way adjustable arms. prior confirmation shall be obtain from the officer / Architect for approval. (GROUND + 1ST + 2ND + 3RD + 4TH + 5TH FLOOR) ---- etc., complete with all lead | No | 7469.4 | 7469.4 | 78.0 | False | None | None | False | None | False | 582613.2 | 0 | 3091447 | 106300 | None | code608 | VISTIORS CHAIRS etc, including with all lead & lift, loading & unloading, tools, plants, cost of materials, labour and other incidental charges etc., complete as per specification and as per the directions by the Engineer in charge of the work. (GROUND + 1ST + 2ND + 3RD + 4TH + 5TH FLOOR) ---- etc., complete with all lead | No | 10738.0 | 10738.0 | 110.0 | False | None | None | False | None | False | 1181180.0 | 0 | 3091448 | 106300 | None | code609 | Providing and fixing Centre Teapoy of size of 900 x 600 x 750 mm oval shape as per principal chief architecht dwg no 120816/16 made out of good quality Burma Teak wood legs of cross section 50 x 10 mm and side bars of 50 x 60mm with 12mm thick modi guard glass top wtih edge grainding on polishing of oval shape of 900 x 600mm as per dwg. Polished with melamine finish in spray with necessary compressor Complete with all materials, labour, leads lifts etc and directed by Engineer in charge. Type : Loose Furniture Table Top : 25mm thick E1 grade pre-laminated particle board table top with matching edgebanding and Alluminium Flipup Provision Of Size : 500mm(W) x 135mm(H) is Anodized Finish Considered. Understructure : Aluminium powder coated SOLE Legs (98 degree slant or 90 degree stright Legs) with die cast brackets and MS Powder coated 40x30mm beams are considered to support table top. Modesty : MS powder coated metal modesty is considered in main spine at below table top. Wire Management : MS-Powder coated wiretray with switch plate 150D/300D*120H and vertical cable risers are considered for wire management. (GROUND + 1ST + 2ND + 3RD + 4TH + 5TH FLOOR) ---- etc., complete with all lead | No | 11399.98 | 11399.98 | 59.0 | False | None | None | False | None | False | 672598.82 | 0 | 3091449 | 106300 | None | code610 | Providing and fixing of (Middle back with Plastic Arms + Dsklt With Custamised) etc, including with all lead & lift, loading & unloading, tools, plants, cost of materials, labour and other incidental charges etc., complete as per specification and as per the directions by the Engineer in charge of the work. (GROUND + 1ST + 2ND + 3RD + 4TH + 5TH FLOOR) ---- etc., complete with all lead | Nos | 12649.6 | 12649.6 | 60.0 | False | None | None | False | None | False | 758976.0 | 0 | 3091450 | 106300 | None | code611 | Providing and fixing storage unit of 0.75m width made out of 19mm thick commercial ply vertical support finished in approved 1.5mm laminate with 12mm thick ply packing internally & Externally finish, shelves shall be formed out of 19mm ply finished with 1.5mm laminate of approved shade and colour and 19mm thick shutters formed out of 19mm thick ply finished with 1.5mm thick laminate of approved shade and colour etc., complete the rate includes cost of all materials, labour charges, complete as per specification.Type : Loose Furniture Specifications : Top - Made of 25mm thick E1 grade pre-laminated particle board . & Body - Made of 18mm thick pre-laminated particle board with openable shutters and Aluminium Finish C- handles + lock and keys. Size : 1200mm(W) x 600mm(D) x 2100mm(H) (GROUND + 1ST + 2ND + 3RD + 4TH + 5TH FLOOR) ---- etc., complete with all lead | Sqm | 15238.52 | 15238.52 | 1111.27 | False | None | None | False | None | False | 16934110.1204 | 0 | 3091451 | 106300 | None | code612 | Optima Chairs with High Back with mesh and lumber support SEAT/BACK ASSEMBLY: The Cushioned seat assembly consists of seat outer (material-30% Glass Fiber Filled Nylon)& upholstered Seat inner (material- Poly Propylene) with moulded Polyurethane foam & polyester fabric. The Net Back is made up of Back outer (material-Glass Fiber Filled Nylon)& Back inner (material- PP) upholstered with polyester Mesh fabric. FULL BACK SIZE: 46.5 cm. (W) x 60.0 cm. (H) SEAT SIZE : 51.0 cm. (W) x 49.0 cm. (D) POLYURETHANE FOAM: The Polyurethane foam is moulded with density = 45 +/- 2 Kg/m , ) ARMRESTS : The armrest is having two adjustment, Height and Depth. Height adjustment is provided in Aluminum structure of armrest which is connected to Aluminum Back spine And is operated by button. The depth adjustment is provided in pad which is fixed to armrest structure. Armrest Top is made up of PU molded over plastic inner. LUMBAR SUPPORT ASSEMBLY: The Lumbar suport assembly consists of lumbar spine (material-Glass Fiber Filled Nylon) which is fixed to Aluminum Back spine. The Lumbar pad (material- Poly Propylene) is fixed to lumbar spine through lumbar Pad support. Lumbar Support Assembly has height adjustment of 50mm. Neck-rest ASSEMBLY: The Neck-rest assembly consists of upholstered Neck-rest inner (material- Poly Propylene) etc., complete as per the direction of Engineer in charge of the work. (GROUND + 1ST + 2ND + 3RD + 4TH + 5TH FLOOR) ---- etc., complete with all lead | No | 17110.0 | 17110.0 | 95.0 | False | None | None | False | None | False | 1625450.0 | 0 | 3091452 | 106300 | None | code613 | Providing, fabricating and fixing partition frame work consisting of 50mm x 50mm sal wood frame work at spacing not exceeding 600mm c/c fixed to the bottom and ceiling, the partition shall be skinned on both sides using 12mm thick commercial plywood of approved brand termite and water resistance, and top covered with 4mm thick approved quality veneer finished with melamine polish, complete including cost and conveyance of all materials, labour for all items of work, HOM of equipment as per specification. (GROUND + 1ST + 2ND + 3RD + 4TH + 5TH FLOOR) ---- etc., complete with all lead | Sqm | 18188.52 | 18188.52 | 120.0 | False | None | None | False | None | False | 2182622.4 | 0 | 3091453 | 106300 | None | code614 | Supply of High Back Executive Chairs SEAT/BACK ASSEMBLY: The seat is made up of 1.2 cm. thick hot pressed plywood upholsteredwith fabric and moulded Polyurethane Foam. The back is made up 1.2 cm. thick hot pressed plywood upholstered with replaceable fabric upholstery covers and moulded polyurethane foam. The back ply and foam is designed with contoured lumber support for comfortable seating posture. 48cm.(W) X 76.0cm.(H) . POLYURETHANE FOAM: The polyurethane foam for seat and back is mo ulded with density = 45 , ARMRESTS (FIXED):The armrest top is made of moulded polyurethane (P.U) and mounted on to a fixed type M.S. tubular armrest support chrome plated. The arm support has static vertical adjustment of +/-1.5cm.PEDESTAL ASSEMBLY (for PCH-9P01TC/9P02TC): The pedestal is fabricated from steel,chrome plated and assembled with injection moulded black polypropylene hub cap and 5 nos. twin wheel castors (castor wheel dia. 5.0 cm). The pedestal is 66.0cm. Pitch-center dia. (76.0 cm with castors). etc., complete as per the direction of Engineer in charge of the work. (GROUND + 1ST + 2ND + 3RD + 4TH + 5TH FLOOR) ---- etc., complete with all lead | No | 24780.0 | 24780.0 | 55.0 | False | None | None | False | None | False | 1362900.0 | 0 | 3091454 | 106300 | None | code615 | Providing and fixing Main table 1500x750x735mm, table top 25mm thick PLPB 1000x450x735mm, 25 MM THICK PLAIN PARTICLE BOARD (PPB) CLAD WITH 0.6MMTHICK POST FORMED LAMINATE AND 1MM THICK Main and Side tables BACKINGLAMINATE (BDL). FLAT EDGE DULY SEALED WITH 2MM THICKPVC BEADING.18MM THICK PLAIN PARTICLE BOARD (PPB)CLAD WITH 1.0MM THICK DECORATIVE LAMINATE (DL) ON BOTH SIDES. EDGE SEALED WITH 2MM THICK PVC BEADING 25 MM THICK PLAIN PARTICLE BOARD (PPB) CLAD WITH 0.6MMTHICK POST FORMED LAMINATE AND 1MM THICK BACKINGLAMINATE (BDL). FLAT EDGE DULY SEALED WITH 2MM THICKPVC BEADING.18MM THICK PLAIN PARTICLE BOARD (PPB)CLAD WITH 1.0MM THICK DECORATIVE LAMINATE (DL) ON BOTHSIDES. EDGE SEALED WITH 2MM THICK PVC BEADING. etc. as per approved drawing and directed by the engineer in charge. (GROUND + 1ST + 2ND + 3RD + 4TH + 5TH FLOOR) ---- etc., complete with all lead | Set | 27730.0 | 27730.0 | 3.0 | False | None | None | False | None | False | 83190.0 | 0 | 3091455 | 106300 | None | code616 | Providing and fixing of DINING TABLES WITH CHAIRS etc, including with all lead & lift, loading & unloading, tools, plants, cost of materials, labour and other incidental charges etc., complete as per specification and as per the directions by the Engineer in charge of the work. (GROUND + 1ST + 2ND + 3RD + 4TH + 5TH FLOOR) ---- etc., complete with all lead | No | 28786.1 | 28786.1 | 10.0 | False | None | None | False | None | False | 287861.0 | 0 | 3091456 | 106300 | None | code617 | PROVIDING ALL SAFE OFFICE LOCKER STEEL ALMIRAH (900X1800X600). depth with 5 shelves of 14 gauge powder coated the rate including one locker (GROUND + 1ST + 2ND + 3RD + 4TH + 5TH FLOOR) ---- etc., complete with all lead | No | 30066.53 | 30066.53 | 35.0 | False | None | None | False | None | False | 1052328.55 | 0 | 3091457 | 106300 | None | code618 | DRINKING WATER COOLER : Providing and installing water cooler ss body and ss tank with specification Storage Capacity 80 Ltr, Normal cooling capacity 40Ltr, No of Faucets 2nos, Dimensions (MM) 665W x 480 D x 1210H, weight 47Kg, Glasses Per hr 200Ltr, Refrigerant R-134a, current (amps)2.50, water over flow 1/2BSP, Typer of Compresser REIP. Including UV Corbon & Sediment filter of 250L PH water Purifier Fixing Seperatly duly connect. The rate to includ of water piping From OHT To Necessary drainage system for out let, angle cock system for as per specification. (GROUND FLOOR) (GROUND + 1ST + 2ND + 3RD + 4TH + 5TH FLOOR) ---- etc., complete with all lead | No | 35352.8 | 35352.8 | 12.0 | False | None | None | False | None | False | 424233.6 | 0 | 3091458 | 106300 | None | code619 | Providing and fixing of Three Seater Stainless Steel Waiting Chair complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. (Hassan Approved Rate) (GROUND + 1ST + 2ND + 3RD + 4TH + 5TH FLOOR) ---- etc., complete with all lead | No | 42480.0 | 42480.0 | 141.0 | False | None | None | False | None | False | 5989680.0 | 0 | 3091459 | 106300 | None | code620 | Single seater sofa Teakwood Sofa Chair Size : 900 x 750 x 800 Providing and supplying fully upholstered single seater sofa with arm rest. Structure to be made of teakwood arm rest of size 100x38x750mm and silverwood frame of 100mmx38mm and 75mm x 38mm size along with 6mm MDF for necessary covering to back and arm rest sides. Provision of 100mm thick foam rubber of ISI grade reputed make for seat fixed on elastic springs / navar and 75mm thick foam rubber for back rest with 25mm foam rubber for arm rest. With 12mm foam rubber slab for edge binding. Fixing 25mm thick PU foam to seat and back for additional padding. Covering of gray cloth ( thick quality) on entire sofa seat, back, arm rest. Fixing good quality tapestry as per approved shade and design of basic price not less than Rs. 454/- per meter (including VAT) Complete with including , materials, labours, taxes, leads lifts and as per directed by Engineer-In-Charge. Name:ATLANTE Type: Single seater Sofa Size: 720mm(W) x 720mm(D) x 730mm(H) Top: Upholstery with Fabric Finish Specifications:The sofas are made of solid wood base, reinforced with supportive addendum in the seat.Engineered wood panels form/support the overall design structure, They synergise with the solid wood to offer unparalleled life to the product.Foam padding of multidensity and varying thicknesses provide cushion for the sofa. PU foam used is made Hennecke foam plants using German Technology capable of producing the high quality flexible polyurethane foam. It provides unparalleled comfort, ease of use and durability. The foam used is 32 Density for seating areas and 28 Density for backrest. The supersoft foam used is in seating areas in 32-35 Density High-resilience (HR) foam which is unique and rarely used by manufacturers.
Webbing: Interwoven high tensile elastic bands for optimum comfort and endurance.
Understructure:Base With Solid Wooden Finish Legs (GROUND + 1ST + 2ND + 3RD + 4TH + 5TH FLOOR) ---- etc., complete with all lead | Each | 44541.49 | 44541.49 | 10.0 | False | None | None | False | None | False | 445414.9 | 0 | 3091460 | 106300 | None | code621 | WORKSTATION of size 1500x1350x 1200mm Ht . Frames /Partition thickness is 50mm for stability and with the inside gap between two tile is approximately 50mm for higher wire carrying capacity. Frame verticals are made of Aluminium Extrusions of 1.2mm thick and Horizontals are made of 1mm thick C RCAsheets. All the frames duly powder coated based on the choice of the Powder Coat colour as per Customers choice which includes Top trims & end trims All the frames are fastened together by means of M6 NUTS & BOLTS . They can be attached to form a 2-way, 3-way or a 4-way configuration. All the Caps viz end, inline & universal & raceway caps are made out of Die-cast Aluminum. These caps also are finished in an epoxy powder coating finish in the same color. All the frames are fitted with M10 leveling bolts. Raceway :-The raceways are made out of 0.8mm thick CRCA & powder coated. The electrical raceway can be provided below worktop or above worktop, these are hookon type which will be mounted on the verticals. The skirting/data raceway is hollow and will be mounted on the raceway channels. Tiles: Fabric Tile: Constructed out of 4mm thick Medium Density Fiber Board (MDF) and covered with Fabric of choice. Bottom Row of Metal Tiles,made of 0.8mm CRCA sheet and finished in epoxy powder coating. Can be given with plain / perforations / embossed finishes. Magnetic tile: Constructed out of 0.8mm Galvanized sheet and covered with fabric of choice. Whiteboard marker tiles: Made out of 4mm MDF with 1mm glossy highly wear resistant face laminate with a balancing laminate on the back. Total thickness is 5mm. Table tops and Gable ends are of 25mm thk Pre-laminated particleboards conforming to IS : 12823 Interior Grade. Specially designed powder coated M.S. brackets fixed to the partition frame support the tabletops. Gable ends are of 25mm thk. both side laminate (BSL) with 2mm PVC imported edge banding on front side. Sealed edge in table top and gable ends are with 0.8mm PVC imported edge banding. PVC edge banding . One no of 3 Drawer prealmimnated pedestal unit wiht 2 box and 1 file drawer of size 400x470x670mm Ht -Open office workstation 1500x1350mm ---- etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. Type : Loose Furniture Table Top : 25mm thick E1 grade pre-laminated particle board table top with matching edgebanding and Alluminium Flipup Provision Of Size : 500mm(W) x 135mm(H) is Anodized Finish Considered. Understructure : Aluminium powder coated SOLE Legs (98 degree slant or 90 degree stright Legs) with die cast brackets and MS Powder coated 40x30mm beams are considered to support table top. Modesty : MS powder coated metal modesty is considered in main spine at below table top. Wire Management : MS-Powder coated wiretray with switch plate 150D/300D*120H and vertical cable risers are considered for wire management. (GROUND + 1ST + 2ND + 3RD + 4TH + 5TH FLOOR) ---- etc., complete with all lead | Nos | 44840.0 | 44840.0 | 20.0 | False | None | None | False | None | False | 896800.0 | 0 | 3091461 | 106300 | None | code622 | Providing and fixing meeting table consisting of 25 mm thick PLPB table top edge bounded, 25 mm thick PLPB with edge bonded End table, 18 mm thick PLPB with edge bonded Modesty, Hardware-Minifix assembly and screw leg, as per specifications, drawings and as directed by Engineer in charge. 2400 mm Dia x 1200 mm D x 750 mm Ht (12 seater)Type : Loose Furniture Table Top : 25mm thick E1 grade pre-laminated particle board table top with matching edgebanding and Alluminium Flipup Provision Of Size : 500mm(W) x 135mm(H) is Anodized Finish Considered. Understructure : Aluminium powder coated SOLE Legs (98 degree slant or 90 degree stright Legs) with die cast brackets and MS Powder coated 40x30mm beams are considered to support table top. Wire Management : MS-Powder coated wiretray with switch plate 150D/300D*120H and vertical cable risers are considered for wire management. (GROUND + 1ST + 2ND + 3RD + 4TH + 5TH FLOOR) ---- etc., complete with all lead | No | 44930.25 | 44930.25 | 5.0 | False | None | None | False | None | False | 224651.25 | 0 | 3091462 | 106300 | None | code623 | Providing and fixing Library Storage unit BOOK CASE 4 Door etc, including with all lead & lift, loading & unloading, tools, plants, cost of materials, labour and other incidental charges etc., complete as per specification and as per the directions by the Engineer in charge of the work. Type :Loose Furniture Specifications : Top - Made of 25mm thick E1 grade pre-laminated particle board . & Body - Made of 18mm thick pre-laminated particle board with openable shutters and Aluminium Finish C- handles + lock and keys. (GROUND + 1ST + 2ND + 3RD + 4TH + 5TH FLOOR) ---- etc., complete with all lead | No | 46217.11 | 46217.11 | 8.0 | False | None | None | False | None | False | 369736.88 | 0 | 3091463 | 106300 | None | code624 | DRINKING WATER COOLER : Providing and installing water cooler ss body and ss tank with specification Storage Capacity 80 Ltr, Normal cooling capacity 40Ltr, No of Faucets 2nos, Dimensions (MM) 665W x 480 D x 1210H, weight 47Kg, Glasses Per hr 200Ltr, Refrigerant R-134a, current (amps)2.50, water over flow 1/2BSP, Typer of Compresser REIP. Including UV Corbon & Sediment filter of 250L PH water Purifier Fixing Seperatly duly connect. The rate to includ of water piping From OHT To Necessary drainage system for out let, angle cock system for as per specification. (GROUND FLOOR) (GROUND + 1ST + 2ND + 3RD + 4TH + 5TH FLOOR) ---- etc., complete with all lead | No | 47200.0 | 47200.0 | 1.0 | False | None | None | False | None | False | 47200.0 | 0 | 3091464 | 106300 | None | code625 | Table : Providing and fixing Executive tables of different sizes with 19 mm waterproof plywood frame work laminated on all the exposed surface with 1 mm thick laminate and a key board tray is provided and all edges of the plywood is lipped with 19mm x 6mm teak/beach wood lipping and the edge of the table top is lipped with 32 mm x 19 mm teak/beach wood lipping. The item to include a side cabinet with 19 mm thick waterproof plywood framework, shelves and shutters laminated on all the exposed surface with 1mm thick laminate and inside surface is also laminate with 0.8 mm laminate. The item to include all hardware like stainless steel hinges, drawer sliders, Euro multipurpose locks, brush steel handles, magnetic catch, all hardware complete and all the teak/beach wood beading is polished. Type : Loose Furniture Table Top : 25mm thick E1 grade pre laminated particle board table top with matching edgebanding and Aluminum flip up provision of Size:- 500mm(W) x135mm(D) Anodized finish. Understructure : Aluminium powder coated SOLE Legs (98 degree slant or 90 degree stright Legs) with die cast brackets and MS Powder coated 40x30mm beams are considered to support table top. Metal Modesty : MS powder coated metal modesty is considered in main spine at below table top. Wire Management : MS-Powder coated wiretray with switch plate 150D/300D 120H and vertical cable risers are considered for wire management. Side Storage Specifications : 400mm width drawer unit + 700mm width open shelfs. Top, Made of 25mm thick E1 grade pre-laminated particle board. Body, Made of 18mm thick pre-laminated particle board with openable shutters and aluminum finish C- handles + lock and keys. Table 2100 mm x 750 mm x 750 mm ht, Side Table 1100 mm x 450 mm x 750 mm ht. (GROUND + 1ST + 2ND + 3RD + 4TH + 5TH FLOOR) ---- etc., complete with all lead | Set | 48397.43 | 48397.43 | 35.0 | False | None | None | False | None | False | 1693910.05 | 0 | 3091465 | 106300 | None | code626 | Two Seater Teakwood Sofa 1350 x 650 x 800 Providing and supplying fully upholstered Two seater sofa with arm rest. Structure to be made of teakwood arm rest of size 100x38x750mm and silverwood frame of 100mmx38mm and 75mm x 38mm size along with 6mm MDF for necessary covering to back and arm rest sides. Provision of 100mm thick foam rubber of ISI grade reputed make for seat fixed on elastic springs / navar and 75mm thick foam rubber for back rest with 25mm foam rubber for arm rest. With 12mm foam rubber slab for edge binding. Fixing 25mm thick PU foam to seat and back for additional padding. Covering of gray cloth ( thick quality on entire sofa seat, back, arm rest. Fixing good quality tapestry as per approved shade and design of basic price not less than Rs.454/- per meter (including VAT) Complete with including , materials, labours, taxes, leads lifts and as per directed by Engineer-In-Charge.Name:ATLANTE Type: 2 seater Sofa Size: 1250mm(W) x 720mm(D) x 730mm (H)
Top: Upholstery with Fabric Finish Specifications:The sofas are made of solid wood base, reinforced with supportive addendum in the seat.Engineered wood panels form/support the overall design structure, They synergise with the solid wood to offer unparalleled life to the product.Foam padding of multidensity and varying thicknesses provide cushion for the sofa. PU foam used is made Hennecke foam plants using German Technology capable of producing the high quality flexible polyurethane foam. It provides unparalleled comfort, ease of use and durability. The foam used is 32 Density for seating areas and 28 Density for backrest. The supersoft foam used is in seating areas in 32-35 Density High-resilience (HR) foam which is unique and rarely used by manufacturers.
Webbing: Interwoven high tensile elastic bands for optimum comfort and endurance.
Understructure:Base With Solid Wooden Finish Legs (GROUND + 1ST + 2ND + 3RD + 4TH + 5TH FLOOR) ---- etc., complete with all lead | Each | 54132.61 | 54132.61 | 10.0 | False | None | None | False | None | False | 541326.1 | 0 | 3091466 | 106300 | None | code627 | WORKSTATION of size 2400x1350x 1200mm Ht , Frames / Partition thickness is 60mm for stability and with the inside gap between two tile is approximately 50mm for higher wire carrying capacity. Frame verticals are made of Aluminium Extrusions of 1.2mm thick and Horizontals are made of 1mm thick C RCAsheets. All the frames duly powder coated based on the choice of the Powder Coat colour as per Customers choice which includes Top trims & end trims All the frames are fastened together by means of M6 NUTS & BOLTS . They can be attached to form a 2-way, 3-way or a 4-way configuration. All the Caps viz end, inline & universal & raceway caps are made out of Die-cast Aluminum. These caps also are finished in an epoxy powder coating finish in the same color. All the frames are fitted with M10 leveling bolts. Raceway :-The raceways are made out of 0.8mm thick CRCA & powder coated. The electrical raceway can be provided below worktop or above worktop, these are hookon type which will be mounted on the verticals. The skirting/data raceway is hollow and will be mounted on the raceway channels. Tiles: Fabric Tile: Constructed out of 4mm thick Medium Density Fiber Board (MDF) and covered with Fabric of choice. Bottom Row of Metal Tiles,made of 0.8mm CRCA sheet and finished in epoxy powder coating. Can be given with plain / perforations / embossed finishes. Magnetic tile: Constructed out of 0.8mm Galvanized sheet and covered with fabric of choice. Whiteboard marker tiles: Made out of 4mm MDF with 1mm glossy highly wear resistant face laminate with a balancing laminate on the back. Total thickness is 5mm. Table tops and Gable ends are of 25mm thk Pre-laminated particleboards conforming to IS : 12823 Interior Grade. Specially designed powder coated M.S. brackets fixed to the partition frame support the tabletops. Gable ends are of 25mm thk. both side laminate (BSL) with 2mm PVC imported edge banding on front side. Sealed edge in table top and gable ends are with 0.8mm PVC imported edge banding. PVC edge banding are imported. One no of 3 Drawer prealmimnated pedestal unit wiht 2 box and 1 file drawer of size400x470x670mm Ht Open office workstation 2400x1350mm ---- etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. Type : Loose Furniture Table Top : 25mm thick E1 grade pre-laminated particle board table top with matching edgebanding and Alluminium Flipup Provision Of Size : 500mm(W) x 135mm(H) is Anodized Finish Considered. Understructure : Aluminium powder coated SOLE Legs (98 degree slant or 90 degree stright Legs) with die cast brackets and MS Powder coated 40x30mm beams are considered to support table top. Modesty : MS powder coated metal modesty is considered in main spine at below table top. Wire Management : MS-Powder coated wiretray with switch plate 150D/300D*120H and vertical cable risers are considered for wire management. (GROUND + 1ST + 2ND + 3RD + 4TH + 5TH FLOOR) ---- etc., complete with all lead | No | 56050.0 | 56050.0 | 14.0 | False | None | None | False | None | False | 784700.0 | 0 | 3091467 | 106300 | None | code628 | Providing and fixing Main table 1500x750x735mm, table top 25mm thick PLPB 1000x450x735mm, 25 MM THICK PLAIN PARTICLE BOARD (PPB) CLAD WITH 0.6MMTHICK POST FORMED LAMINATE AND 1MM THICK Main and Side tables BACKINGLAMINATE (BDL). FLAT EDGE DULY SEALED WITH 2MM THICKPVC BEADING.18MM THICK PLAIN PARTICLE BOARD (PPB)CLAD WITH 1.0MM THICK DECORATIVE LAMINATE (DL) ON BOTH SIDES. EDGE SEALED WITH 2MM THICK PVC BEADING 25 MM THICK PLAIN PARTICLE BOARD (PPB) CLAD WITH 0.6MMTHICK POST FORMED LAMINATE AND 1MM THICK BACKINGLAMINATE (BDL). FLAT EDGE DULY SEALED WITH 2MM THICKPVC BEADING.18MM THICK PLAIN PARTICLE BOARD (PPB)CLAD WITH 1.0MM THICK DECORATIVE LAMINATE (DL) ON BOTHSIDES. EDGE SEALED WITH 2MM THICK PVC BEADING. etc. as per approved drawing and directed by the engineer in charge. Type : Loose Furniture Table Top : 25mm thick E1 grade pre-laminated particle board table top with matching edgebanding and Aluminum flip up provision of Size:- 500mm(W) x135mm(D) Anodized finish. Understructure : Aluminium powder coated SOLE Legs (98 degree slant or 90 degree stright Legs) with die cast brackets and MS Powder coated 40x30mm beams are considered to support table top. Metal Modesty : MS powder coated metal modesty is considered in main spine at below table top. Wire Management : MS-Powder coated wiretray with switch plate 150D/300D*120H and vertical cable risers are considered for wire management. Side Storage Specifications : 400mm width drawer unit + 600mm width open shelfs. Top:- Made of 25mm thick E1 grade pre-laminated particle board. Body:- Made of 18mm thick pre-laminated particle board with openable shutters and aluminum finish C- handles + lock and keys. (GROUND + 1ST + 2ND + 3RD + 4TH + 5TH FLOOR) ---- etc., complete with all lead | No | 59590.0 | 59590.0 | 5.0 | False | None | None | False | None | False | 297950.0 | 0 | 3091468 | 106300 | None | code629 | SOFA - 3 SEATER Teakwood Sofa Providing and supplying and placing Three Seater sofa of over all size 1800 x 750 x 750 Structure to be made of teakwood arm rest of size 100x38x750mm and silverwood frame of 100mmx38mm and 75mm x 38mm size along with 6mm MDF of requisite manufacturer for necessary covering from back and arm rests. The seat shall be 125mm and back shall be of 100mm thick duly covered with tepastory fabric of Rs. 454/- ( Including tax ) per meter including necessary Hardware, Navar, Jute cloth, casement, springs etc. including all leads, lifts, taxes and HOM machineries etc complete as per Architect design and as directed by Engineer-In-charge Name:ATLANTE Type:3 seater Sofa Size: 1800mm(W) x 720mm(D) x 730mm (H) Top: Upholstery with Fabric Finish Specifications:The sofas are made of solid wood base, reinforced with supportive addendum in the seat.Engineered wood panels form/support the overall design structure, They synergise with the solid wood to offer unparalleled life to the product.Foam padding of multidensity and varying thicknesses provide cushion for the sofa. PU foam used is made Hennecke foam plants using German Technology capable of producing the high quality flexible polyurethane foam. It provides unparalleled comfort, ease of use and durability. The foam used is 32 Density for seating areas and 28 Density for backrest. The supersoft foam used is in seating areas in 32-35 Density High-resilience (HR) foam which is unique and rarely used by manufacturers.
Webbing: Interwoven high tensile elastic bands for optimum comfort and endurance.
Understructure:Base With Solid Wooden Finish Legs (GROUND + 1ST + 2ND + 3RD + 4TH + 5TH FLOOR) ---- etc., complete with all lead | Each | 62730.74 | 62730.74 | 10.0 | False | None | None | False | None | False | 627307.4 | 0 | 3091469 | 106300 | None | code630 | Table : Providing and fixing Executive tables of different sizes with 19 mm waterproof plywood frame work laminated on all the exposed surface with 1 mm thick laminate and a key board tray is provided and all edges of the plywood is lipped with 19mm x 6mm teak/beach wood lipping and the edge of the table top is lipped with 32 mm x 19 mm teak/beach wood lipping. The item to include a side cabinet with 19 mm thick waterproof plywood framework, shelves and shutters laminated on all the exposed surface with 1mm thick laminate and inside surface is also laminate with 0.8 mm laminate. The item to include all hardware like stainless steel hinges, drawer sliders, Euro multipurpose locks, brush steel handles, magnetic catch, all hardware complete and all the teak/beach wood beading is polished. Table 2400 mm x 900 mm x 750 mm ht, Side Table 1100 mm x 450 mm x 750 mm ht. (GROUND + 1ST + 2ND + 3RD + 4TH + 5TH FLOOR) ---- etc., complete with all lead | Set | 96288.35 | 96288.35 | 58.0 | False | None | None | False | None | False | 5584724.3 | 0 | 3091470 | 106300 | None | code631 | MODULAR KITCHEN:
1)WORK TABLE WITH UNDER SHELF,SIZE:24 X 24 X 24+6 2 Nos, 2) FRYER TABLE TOP TWIN TANK(16 LTR CAPACITY) 01 No, 3) WORK TABLE WITH UP STAND,SIZE:48 X 24 X 34+6 01 No 4) BATTER TABLE,SIZE:24 X 24 X 34 01 No 5) IDLY STEAMER(120 IDLY CAPACITY) 01 No 6) DOUBLE JACKET VESSEL(75 LTR CAPACITY) 01 No 7) SINGLE JACKET VESSEL(75 LTR CAPACITY) 01 No 8) STEAM GENERATOR(18 KW) 01 No 9) WORK TABLE WITH UNDER SHELF,SIZE:24 X 24 X 34+6 01 No 10) CORNER STORAGE UNIT TABLE WITH 3 COVERING,SIZE:84 X 24 X 34+6 01 No 11) 1 SET OF SINGLE BURNER WITH TWO BURNER RANGE WITH LANDING TABLE SIZE:68 X 24 X 34 01 No 12) STOCK POT STOVE,SIZE:24 X 24 X 24 02 No’s 13) CORNER STORAGE UNIT WITH TABLE 3 COVERING,SIZE:84 X 24 X 34+6 01 No 14) WET GRINDER & MIXER MACHINE COMMERCIAL TYPE UP TO 20 KgS 01 No 15) CHAPATHI KNEADER(10-15 Kg CAPACITY) 01 No 16) MILK BOILER(15 LTR CAPACITY) 01 No 17) DOUBLE DECK OVEN(PIZZA OWEN WITH DOUBLE DECK) 01 No 18) UTENSEL STORAGE RACK WITH 3 SHELF,SIZE:60 X 24 X 72 01 No 19) POT WASHING,SIZE:36 X 24 X 34+6 01 No 20) CHAPATI PLATE PUFFER,SIZE:60 X 24 X 34+6 01 No 21) PREPARATION TABLE WITH 2 U/S-WORK TABLE WITH OHS SIZE:60 X 24 X 34+18+6 01 No 22) SINK WORK TABLE WITH OHS,SIZE:48 X 24 X 34+6 01 No 23) MOVABLE CHOPPING SPIDER TABLE,SIZE:48 X 24 34+6 01 No 24) POT RACK,SIZE:48 X 20 X 72 01 No 25) PLATE RACK-150 PLATES,SIZE:48 X 12 X 44 01 No 26) SS 4 DOOR VERTICAL REFRIGERAYOR(SS COMMERCIAL WITH SINGLE PHASE) 01 No 27) STORAGE RACK WITH SHELVES FOR GROCERY STORAGE with adjustable nylon bullet fit (44X24X76) 01 No 28) STORAGE RACK WITH SHELVES FOR GROCERY STORAGE with adjustable nylon bullet fit (62X24X76) 01 No 29) STORAGE RACK WITH SHELVES FOR GROCERY STORAGE with adjustable nylon bullet fit (36X24X76) 01 No 30) MOBILE GARBAGE BIN(WITH WHEEL STAND) 03 No 31) DEEP FREEZERS (chiller 1 9 degree of cooling capacity) 01 No 32) HOT FOOD SERVICE TROLLEY,SIZE:48 X 24 34 01 No 33) 2 TIER TROLLEY,SIZE:48 X 24 X 30 02 No’s 34) GAS LINE (ms 20 mm pipe) 65 No 35) STEAM LINE (SS pipe) 38 No’s 36) SS EXHAUST WITH BLOWER (SS Exhaust with include of suction hood, suction filter, suction canvas exhaust duct and centrifugal blower with 0.8 sheet of with filter) 18 No’s 37) GI DUCTING FOR EXHAUST (Inclusive of GI ducting, round bend section) 90 SFT 38) FRESH AIR BLOWER (5 HP motor for air blower , air capacity 1100 m3/hr air suction capacity 1800 CFM with GI Sheet ) 01 SET 39) GI DUCTING FOR FRESH AIR DUCTING (Rates are inclusive of GI ducting, round bend section) 45 SFTcomplete as per specifications as per the directions and instructions of the engineer- in charge of the work. ---- etc., complete with all lead | No | 4704196.43 | 4704196.43 | 2.0 | False | None | None | False | None | False | 9408392.86 | 0 | 3091471 | 106300 | None | code632 | Laundry Equipments--Supply,Installation,Testing&Commisioining Washer Extractor Make: IFB/ Stefab,Model: RVWE 60,Capapcity : 60 Kgs,Heating: Electrical,HSN Code: 84514099 ---- etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead | Each | 2356356.75 | 2356356.75 | 1.0 | False | None | None | False | None | False | 2356356.75 | 0 | 3091472 | 106300 | None | code633 | Supply,Installation,Testing&Commisioining Washer Extractor,Make: IFB/ Stefab,Model: RVWE 30,Capapcity : 30 Kgs,Heating: Electrical,HSN Code: 84514099---- etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead | Each | 1383175.84 | 1383175.84 | 1.0 | False | None | None | False | None | False | 1383175.84 | 0 | 3091473 | 106300 | None | code634 | Supply,Installation,Testing & Commisioining Washer Extractor,Make: IFB/ Stefab,Model: IWE 108,Capapcity : 10 Kgs,Heating: Electrical,HSN Code: 84514099---- etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead | Each | 518064.25 | 518064.25 | 1.0 | False | None | None | False | None | False | 518064.25 | 0 | 3091474 | 106300 | None | code635 | Supply,Installation,Testing & Commisioining Tumble Drier,Make: IFB/ Stefab,Model: RTD 60,Capapcity : 60 Kgs,Heating: Electrical,HSN Code: 84512900---- etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead | Each | 974852.08 | 974852.08 | 2.0 | False | None | None | False | None | False | 1949704.16 | 0 | 3091475 | 106300 | None | code636 | Supply,Installation,Testing & Commisioining Flat work ironer,Make: IFB/ Stefab,Model: RFWI 0420E,Size: 2000 *400mm,Heating: Electrical,HSN Code: 84513090---- etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead | Each | 1392645.83 | 1392645.83 | 1.0 | False | None | None | False | None | False | 1392645.83 | 0 | 3091476 | 106300 | None | code637 | Supply,Installation,Testing & Commisioining Flat bed press,Make: IFB/ Stefab,Model: RFBP,Size: 1500 *750mm,Heating: Electrical,HSN Code: 84513090---- etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead | Each | 780160.2 | 780160.2 | 1.0 | False | None | None | False | None | False | 780160.2 | 0 | 3091477 | 106300 | None | code638 | Supply,Installation,Testing & Commisioining SS Mobile table trollery,Make: VE,Dimention: 80*30*30,HSN Code: 94032010---- etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead | Each | 96092.56 | 96092.56 | 1.0 | False | None | None | False | None | False | 96092.56 | 0 | 3091478 | 106300 | None | code639 | Supply,Installation,Testing & Commisioining SS Mobile trollery,Make: VE,Dimention: 48*36*30,HSN Code: 94032010, complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead | Each | 70189.35 | 70189.35 | 4.0 | False | None | None | False | None | False | 280757.4 | 0 | 3091479 | 106300 | None | code640 | Supply,Installation,Testing & Commisioining Water Harmonizer(50mm) to reduce hardness in water complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead | Each | 501352.5 | 501352.5 | 1.0 | False | None | None | False | None | False | 501352.5 | 0 | 3091480 | 106300 | None | code641 | Supply,Installation,Testing & Commisioining Utility Electrical Control Panel,With MCCB 400A 36KA FP Ics=100%Icu - ABB,with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead | Each | 512493.67 | 512493.67 | 1.0 | False | None | None | False | None | False | 512493.67 | 0 | 3091481 | 106300 | None | code642 | Supply,Installation,Testing & Commisioining Electrical Material & Labour work (25Mtr from our control panel)with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead | Set | 713591.73 | 713591.73 | 1.0 | False | None | None | False | None | False | 713591.73 | 0 | 3091482 | 106300 | None | code643 | Supply,Installation,Testing & Commisioining Plumbing Material & Labour work (100 ft length) with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead | Set | 442861.38 | 442861.38 | 1.0 | False | None | None | False | None | False | 442861.38 | 0 | 3091483 | 106300 | None | code644 | Supply,Installation,Testing & Commisioining Chemicals,Liquid detergent (Deo Rose E )200 ltrs, Sodium Hypochlorite 100 ltrs,Hydrogen peroxide 100 ltrs..with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead | Set | 370443.79 | 370443.79 | 1.0 | False | None | None | False | None | False | 370443.79 | 0 | 3091484 | 106300 | None | code645 | Supply,Installation of Name boards.....with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead | Set | 129124.45 | 129124.45 | 1.0 | False | None | None | False | None | False | 129124.45 | 0 | 3091485 | 106300 | None | code646 | Supplying Installation Testing and Commissioning of Main Control , 3.4GHz/8GB RAM, 1 TB HDD, RS232 Ports, USB Ports, PCI Slot for ISDN/Modem Card, Data Port, Ethernet 100/1000 LAN Card, Standard Keyboard, Standard Optical mouse, 19-22 flat LCD/LED Monitor, Standard Mono laser A4 printer etc. complete as required. NOTE: LINUX based system with matching hardware details satisfying the performance parameters of the PTTS shall also be acceptable Included
*Main Control Unit Hardware (Viz: CPU, Monitor Keyboard, Mouse, UPS)
*Power Supply Unit with components.Complete with all lead & lift and work to be executed as per specification and Engineer Incharge of the work.a)Supply ---- etc., complete with all lead | No | 731446.6 | 731446.6 | 2.0 | False | None | None | False | None | False | 1462893.2 | 0 | 3091486 | 106300 | None | code647 | Supplying Installation Testing and Commissioning of Main Control , 3.4GHz/8GB RAM, 1 TB HDD, RS232 Ports, USB Ports, PCI Slot for ISDN/Modem Card, Data Port, Ethernet 100/1000 LAN Card, Standard Keyboard, Standard Optical mouse, 19-22 flat LCD/LED Monitor, Standard Mono laser A4 printer etc. complete as required. NOTE: LINUX based system with matching hardware details satisfying the performance parameters of the PTTS shall also be acceptable Included
*Main Control Unit Hardware (Viz: CPU, Monitor Keyboard, Mouse, UPS)
*Power Supply Unit with components.Complete with all lead & lift and work to be executed as per specification and Engineer Incharge of the work.b)Installation ---- etc., complete with all lead | No | 52918.28 | 52918.28 | 2.0 | False | None | None | False | None | False | 105836.56 | 0 | 3091487 | 106300 | None | code648 | Supplying Installation Testing and Commissioning of Control software (pre-loaded on Control PC) with Network viewing; System access and controls for each device on the network; Traffic flow analysis; Delay analysis; Logging of each transaction and error; with transcation ID, Carrier ID send station ID, Receive Station ID, start time and End/Receive time with dates including, Inventory controls;Location of carriers, Password controls, Carrier re-distribution; Pro-remote accessibility; Automatic Return feature of carriers to origin or to station with highest deficit programmable timetable for recurring functions etc complete as required.
* Software package for Central Controller-
*Software for one Line
*Extension Software for Further Lines
*Editor Software
*Software for Code-Tag System
*Linux based system for improved security
Complete with all lead & lift and work to be executed as per specification and Engineer Incharge of the work.a)Supply ---- etc., complete with all lead | No | 548832.16 | 548832.16 | 2.0 | False | None | None | False | None | False | 1097664.32 | 0 | 3091488 | 106300 | None | code649 | Supplying Installation Testing and Commissioning of Control software (pre-loaded on Control PC) with Network viewing; System access and controls for each device on the network; Traffic flow analysis; Delay analysis; Logging of each transaction and error; with transcation ID, Carrier ID send station ID, Receive Station ID, start time and End/Receive time with dates including, Inventory controls;Location of carriers, Password controls, Carrier re-distribution; Pro-remote accessibility; Automatic Return feature of carriers to origin or to station with highest deficit programmable timetable for recurring functions etc complete as required.
* Software package for Central Controller-
*Software for one Line
*Extension Software for Further Lines
*Editor Software
*Software for Code-Tag System
*Linux based system for improved security
Complete with all lead & lift and work to be executed as per specification and Engineer Incharge of the work.b)Installation ---- etc., complete with all lead | No | 43720.18 | 43720.18 | 2.0 | False | None | None | False | None | False | 87440.36 | 0 | 3091489 | 106300 | None | code650 | Supplying Installation Testing and Commissioning of Side Channel Blowers with VFD conforming to EC machines directives 98/37/EC and low voltage director 73/23/EEC; DIN EN292 for safety of machines; EN60034-1 DIN VDE 0530 Part 1 for rotating electrical machines; EN 60034-5 / DIN VDE 0530-5 classification of degree of protection DIN EN 60204 for safety of machine electrical equipment of machine etc. complete as required. Blowers maximum 5.5 kW, 3 phase 400v/50Hz, minimum 3100 rpm with minimum 200 mbar pressure, with low noise, unidirectional rotation with electronic air switch to switch between compressed air and vacuum. Each blower should be provided with Frequency Converter or VFD for Control of slow speed for sensitive laboratory samples by frequency control of Compressor. The blower should be set go up to 75Hz with the help of Frequency Converter.Complete with all lead & lift and work to be executed as per specification and Engineer Incharge of the work.a) Supply 5.5kw ---- etc., complete with all lead | No | 581904.02 | 581904.02 | 2.0 | False | None | None | False | None | False | 1163808.04 | 0 | 3091490 | 106300 | None | code651 | Supplying Installation Testing and Commissioning of Side Channel Blowers with VFD conforming to EC machines directives 98/37/EC and low voltage director 73/23/EEC; DIN EN292 for safety of machines; EN60034-1 DIN VDE 0530 Part 1 for rotating electrical machines; EN 60034-5 / DIN VDE 0530-5 classification of degree of protection DIN EN 60204 for safety of machine electrical equipment of machine etc. complete as required. Blowers maximum 5.5 kW, 3 phase 400v/50Hz, minimum 3100 rpm with minimum 200 mbar pressure, with low noise, unidirectional rotation with electronic air switch to switch between compressed air and vacuum. Each blower should be provided with Frequency Converter or VFD for Control of slow speed for sensitive laboratory samples by frequency control of Compressor. The blower should be set go up to 75Hz with the help of Frequency Converter.Complete with all lead & lift and work to be executed as per specification and Engineer Incharge of the work.b) Installation ---- etc., complete with all lead | No | 55660.6 | 55660.6 | 2.0 | False | None | None | False | None | False | 111321.2 | 0 | 3091491 | 106300 | None | code652 | Supplying, installation, testing & commissioning of Top load Standard or Compact Stations conforming to EU Director for Electromagnetic tolerance 2004/108/EC; EEC directive for low voltage devices 93/68/EEC; EEC machines directors 98/37/EEC. Stations are equipped with RFID readers for various functions such as Carrier ID and inventory, Carrier ID with properties, permitted addresses or groups, automatic destination, reject items not identifiable etc. complete as required.
* The container loaded on the top/ front side of the Pneumatic Station.
*The Pneumatic Station have Air cushioned soft landing facility for arriving container to protect samples. Provided with container rack and receiving basket with cushion.
* All the stations Delivered with RF ID reader and Antenna ,this helps in proper management of Carriers with the help of return of empty carrier. It also does not allow anything else to go in the system, but the carrier. All stations should have RFID reader Cards for the carrier, duly installed in the dispatch magazine.Complete with all lead & lift and work to be executed as per specification and Engineer Incharge of the work.a)Supply ---- etc., complete with all lead | No | 245111.96 | 245111.96 | 10.0 | False | None | None | False | None | False | 2451119.6 | 0 | 3091492 | 106300 | None | code653 | Supplying, installation, testing & commissioning of Top load Standard or Compact Stations conforming to EU Director for Electromagnetic tolerance 2004/108/EC; EEC directive for low voltage devices 93/68/EEC; EEC machines directors 98/37/EEC. Stations are equipped with RFID readers for various functions such as Carrier ID and inventory, Carrier ID with properties, permitted addresses or groups, automatic destination, reject items not identifiable etc. complete as required.
* The container loaded on the top/ front side of the Pneumatic Station.
*The Pneumatic Station have Air cushioned soft landing facility for arriving container to protect samples. Provided with container rack and receiving basket with cushion.
* All the stations Delivered with RF ID reader and Antenna ,this helps in proper management of Carriers with the help of return of empty carrier. It also does not allow anything else to go in the system, but the carrier. All stations should have RFID reader Cards for the carrier, duly installed in the dispatch magazine.Complete with all lead & lift and work to be executed as per specification and Engineer Incharge of the work.b)Installation ---- etc., complete with all lead | No | 23411.2 | 23411.2 | 10.0 | False | None | None | False | None | False | 234112.0 | 0 | 3091493 | 106300 | None | code654 | Supplying, installation, testing & commissioning of Lab Stations conforming to EU Director for Electromagnetic tolerance 2004/108/EC; EEC directive for low voltage devices 93/68/EEC; EEC machines directors 98/37/EEC. Stations are equipped with RFID readers for various functions such as Carrier ID and inventory, Carrier ID with properties, permitted addresses or groups, automatic destination, reject items not identifiable etc. complete as required.
* The container loaded on the top/ front side of the Pneumatic Station with multy receiving bow-SS (1 send & 1 receiving Lab station)
*The Pneumatic Station have Air cushioned soft landing facility for arriving container to protect samples. Provided with container rack and receiving basket with cushion.
* All the stations Delivered with RF ID reader and Antenna ,this helps in proper management of Carriers with the help of return of empty carrier. It also does not allow anything else to go in the system, but the carrier. All stations should have RFID reader Cards for the carrier, duly installed in the dispatch magazine.Complete with all lead & lift and work to be executed as per specification and Engineer Incharge of the work.a)Supply ---- etc., complete with all lead | No | 424800.0 | 424800.0 | 1.0 | False | None | None | False | None | False | 424800.0 | 0 | 3091494 | 106300 | None | code655 | Supplying, installation, testing & commissioning of Lab Stations conforming to EU Director for Electromagnetic tolerance 2004/108/EC; EEC directive for low voltage devices 93/68/EEC; EEC machines directors 98/37/EEC. Stations are equipped with RFID readers for various functions such as Carrier ID and inventory, Carrier ID with properties, permitted addresses or groups, automatic destination, reject items not identifiable etc. complete as required.
* The container loaded on the top/ front side of the Pneumatic Station with multy receiving bow-SS (1 send & 1 receiving Lab station)
*The Pneumatic Station have Air cushioned soft landing facility for arriving container to protect samples. Provided with container rack and receiving basket with cushion.
* All the stations Delivered with RF ID reader and Antenna ,this helps in proper management of Carriers with the help of return of empty carrier. It also does not allow anything else to go in the system, but the carrier. All stations should have RFID reader Cards for the carrier, duly installed in the dispatch magazine.Complete with all lead & lift and work to be executed as per specification and Engineer Incharge of the work.b)Installation ---- etc., complete with all lead | No | 26980.7 | 26980.7 | 1.0 | False | None | None | False | None | False | 26980.7 | 0 | 3091495 | 106300 | None | code656 | Supplying, installation, testing & commissioning of Diverter Units conforming to EU Director for Electromagnetic tolerance 2004/108/EC; EEC directive for low voltage devices 93/68/EEC; EEC MACHINES directors 98/37/EEC. And fitted with optical sensor to detect passage of the carrier with moveable tube that gently guides the carrier through the divertor in pre and auto-selected direction and electromagnetic radio-frequency interference for LVDC 36Vusing RS232 to RS485 platform using unicore cable based on RS485 connectivity which provides composite LV power supply and communication etc. as required.
*NW diverter 3 way type, air tight with touch free position and tube switches, steel housing complete with Rohr Bahn optical sensors complete as required.Complete with all lead & lift and work to be executed as per specification and Engineer Incharge of the work.a)Supply ---- etc., complete with all lead | No | 194985.56 | 194985.56 | 5.0 | False | None | None | False | None | False | 974927.8 | 0 | 3091496 | 106300 | None | code657 | Supplying, installation, testing & commissioning of Diverter Units conforming to EU Director for Electromagnetic tolerance 2004/108/EC; EEC directive for low voltage devices 93/68/EEC; EEC MACHINES directors 98/37/EEC. And fitted with optical sensor to detect passage of the carrier with moveable tube that gently guides the carrier through the divertor in pre and auto-selected direction and electromagnetic radio-frequency interference for LVDC 36Vusing RS232 to RS485 platform using unicore cable based on RS485 connectivity which provides composite LV power supply and communication etc. as required.
*NW diverter 3 way type, air tight with touch free position and tube switches, steel housing complete with Rohr Bahn optical sensors complete as required.Complete with all lead & lift and work to be executed as per specification and Engineer Incharge of the work.b)Installation ---- etc., complete with all lead | No | 37403.64 | 37403.64 | 5.0 | False | None | None | False | None | False | 187018.2 | 0 | 3091497 | 106300 | None | code658 | Supplying, installation, testing & commissioning of System Tube Network which should be of special Imported tubes and U-PVC forwarding bends conforming to DIN6660. Tubes and bends should be smoothly connected with PVC sleeves welded together with special PVC welding glue after cleaning with PVC cleaner. The tubes and bends should be mounted at site using thread rods & tube clips at every 2 to 3 meter distance and should be touch with low elastic distortion , high abrasive resistance difficult to inflame in accordance to DIN4102 - should only burn when it is decomposed by very high temperatures constantly of more than 180 degrees celsius - once removed from source of fire the polyvinylchloride extinguishes again complete as required.
*Tube made of PVC of 160 mm OD x 153.6 mm ID. Good Physical tensile strength, general medium density, absorption of water, combustibility self-extinguishing. Colour RAL 7000. Weight per 5 mtr: 10.9 Kgs (approx).Complete with all lead & lift and work to be executed as per specification and Engineer Incharge of the work.a)Supply ---- etc., complete with all lead | m | 3121.1 | 3121.1 | 320.0 | False | None | None | False | None | False | 998752.0 | 0 | 3091498 | 106300 | None | code659 | Supplying, installation, testing & commissioning of System Tube Network which should be of special Imported tubes and U-PVC forwarding bends conforming to DIN6660. Tubes and bends should be smoothly connected with PVC sleeves welded together with special PVC welding glue after cleaning with PVC cleaner. The tubes and bends should be mounted at site using thread rods & tube clips at every 2 to 3 meter distance and should be touch with low elastic distortion , high abrasive resistance difficult to inflame in accordance to DIN4102 - should only burn when it is decomposed by very high temperatures constantly of more than 180 degrees celsius - once removed from source of fire the polyvinylchloride extinguishes again complete as required.
*Tube made of PVC of 160 mm OD x 153.6 mm ID. Good Physical tensile strength, general medium density, absorption of water, combustibility self-extinguishing. Colour RAL 7000. Weight per 5 mtr: 10.9 Kgs (approx).Complete with all lead & lift and work to be executed as per specification and Engineer Incharge of the work.b)Installation ---- etc., complete with all lead | m | 489.7 | 489.7 | 320.0 | False | None | None | False | None | False | 156704.0 | 0 | 3091499 | 106300 | None | code660 | Supplying, installation, testing & commissioning of System Forwarding bends of Wall thickness 3.2mm, Radius 800mm. Special Imported U-PVC forwarding bends conforming to DIN6660 along with necessary accessories like Tube clips, tube clamps, special Glue, Special Cleaner, Pvc sleeves. etc. as required.
* Bend radius 800 mm (centre) with length approx. 1.5 Mtr, for optimal space utilization, grey color. The material should be made up of Polyvinylchloride PVC. Weight : 3.3Kg (approx).Complete with all lead & lift and work to be executed as per specification and Engineer Incharge of the work.a)Supply ---- etc., complete with all lead | m | 17081.68 | 17081.68 | 90.0 | False | None | None | False | None | False | 1537351.2 | 0 | 3091500 | 106300 | None | code661 | Supplying, installation, testing & commissioning of System Forwarding bends of Wall thickness 3.2mm, Radius 800mm. Special Imported U-PVC forwarding bends conforming to DIN6660 along with necessary accessories like Tube clips, tube clamps, special Glue, Special Cleaner, Pvc sleeves. etc. as required.
* Bend radius 800 mm (centre) with length approx. 1.5 Mtr, for optimal space utilization, grey color. The material should be made up of Polyvinylchloride PVC. Weight : 3.3Kg (approx).Complete with all lead & lift and work to be executed as per specification and Engineer Incharge of the work.b)Installation ---- etc., complete with all lead | m | 735.14 | 735.14 | 90.0 | False | None | None | False | None | False | 66162.6 | 0 | 3091501 | 106300 | None | code662 | Supplying, installation, testing & commissioning of System Control Cable of high grade composite with grounding, power and data combined all three in one and should be fully screened and use grounded system concept to minimize electromagnetic and radio-frequency interference complete as required. System cable Supply wire-PVC, compound type YI2 acc. to DIN VDE 207/part 4, Shore A75+/-5 acc. to DIN53 505. Signal wire-PVC, compound type YI3 acc. to DIN VDE 207/part 4 Shore A95 +/- acc. to DIN53 505.
Complete with all lead & lift and work to be executed as per specification and Engineer Incharge of the work.a)Supply ---- etc., complete with all lead | m | 619.5 | 619.5 | 540.0 | False | None | None | False | None | False | 334530.0 | 0 | 3091502 | 106300 | None | code663 | Supplying, installation, testing & commissioning of System Control Cable of high grade composite with grounding, power and data combined all three in one and should be fully screened and use grounded system concept to minimize electromagnetic and radio-frequency interference complete as required. System cable Supply wire-PVC, compound type YI2 acc. to DIN VDE 207/part 4, Shore A75+/-5 acc. to DIN53 505. Signal wire-PVC, compound type YI3 acc. to DIN VDE 207/part 4 Shore A95 +/- acc. to DIN53 505.
Complete with all lead & lift and work to be executed as per specification and Engineer Incharge of the work.b)Installation ---- etc., complete with all lead | m | 29.5 | 29.5 | 540.0 | False | None | None | False | None | False | 15930.0 | 0 | 3091503 | 106300 | None | code664 | Supply & Installation of Transparent PVC PIPE
Transparent PVC tube and bend to PTS be used in technical rooms for
easier technical service and PTS function understanding.
160mm system:
Tube: - Outside diameter 160 mm, thickness 3.2 mm, length 5000mm,
weight 2.21Kg/m to 3.20 Kg/m
Material: - PVC RAL 7011,
Joints are made with glued PVC sleeves. As an option stainless steel band hose clamps can be used.Complete with all lead & lift and work to be executed as per specification and Engineer Incharge of the work.a)Supply Pipe ---- etc., complete with all lead | m | 10759.24 | 10759.24 | 15.0 | False | None | None | False | None | False | 161388.6 | 0 | 3091504 | 106300 | None | code665 | Supply & Installation of Transparent PVC PIPE
Transparent PVC tube and bend to PTS be used in technical rooms for
easier technical service and PTS function understanding.
160mm system:
Tube: - Outside diameter 160 mm, thickness 3.2 mm, length 5000mm,
weight 2.21Kg/m to 3.20 Kg/m
Material: - PVC RAL 7011,
Joints are made with glued PVC sleeves. As an option stainless steel band hose clamps can be used.Complete with all lead & lift and work to be executed as per specification and Engineer Incharge of the work.b)Installation ---- etc., complete with all lead | m | 489.7 | 489.7 | 15.0 | False | None | None | False | None | False | 7345.5 | 0 | 3091505 | 106300 | None | code666 | Supply & Installation of Transparent PVC PIPE BEND
Transparent PVC tube and bend to PTS be used in technical rooms for
easier technical service and PTS function understanding.
160mm system:
Tube: - Outside diameter 160 mm, thickness 3.2 mm, length 5000mm,
weight 2.21Kg/m to 3.20Kg/m
Bend: - Radius 800mm, size 160mmx3.2mm, weight 3.2Kg/m.
Material: - PVC RAL 7011,
Joints are made with glued PVC sleeves. As an option stainless steel band hose clamps can be used.Complete with all lead & lift and work to be executed as per specification and Engineer Incharge of the work.a)Supply Bend ---- etc., complete with all lead | m | 31504.82 | 31504.82 | 10.0 | False | None | None | False | None | False | 315048.2 | 0 | 3091506 | 106300 | None | code667 | Supply & Installation of Transparent PVC PIPE BEND
Transparent PVC tube and bend to PTS be used in technical rooms for
easier technical service and PTS function understanding.
160mm system:
Tube: - Outside diameter 160 mm, thickness 3.2 mm, length 5000mm,
weight 2.21Kg/m to 3.20Kg/m
Bend: - Radius 800mm, size 160mmx3.2mm, weight 3.2Kg/m.
Material: - PVC RAL 7011,
Joints are made with glued PVC sleeves. As an option stainless steel band hose clamps can be used.Complete with all lead & lift and work to be executed as per specification and Engineer Incharge of the work.b)Installation ---- etc., complete with all lead | m | 735.14 | 735.14 | 10.0 | False | None | None | False | None | False | 7351.4 | 0 | 3091507 | 106300 | None | code668 | Supplying, installation, testing & commissioning of Carriers or Capsules for secure use; payload up to 3Kg; Impact resistant and crystal-clear polycarbonate middle body; With Loading Dimensions of 330mmH x 120mm ID /as per OEM; with Swivel caps for secure use; Metal-free design through rotation welding procedure etc. complete as required.
*Inside-loading-dimension for Container 160mm swivel top 115 x 400mm approx. Outer-dimension for Container 160mm swivel top 150 x 420mm approx.
*All the carriers should have RFID programmable chips on both sides of the carrier (2 per carrier).Complete with all lead & lift and work to be executed as per specification and Engineer Incharge of the work.a)Supply ---- etc., complete with all lead | No | 24027.16 | 24027.16 | 30.0 | False | None | None | False | None | False | 720814.8 | 0 | 3091508 | 106300 | None | code669 | Supplying, installation, testing & commissioning of Carriers or Capsules for secure use; payload up to 3Kg; Impact resistant and crystal-clear polycarbonate middle body; With Loading Dimensions of 330mmH x 120mm ID /as per OEM; with Swivel caps for secure use; Metal-free design through rotation welding procedure etc. complete as required.
*Inside-loading-dimension for Container 160mm swivel top 115 x 400mm approx. Outer-dimension for Container 160mm swivel top 150 x 420mm approx.
*All the carriers should have RFID programmable chips on both sides of the carrier (2 per carrier).Complete with all lead & lift and work to be executed as per specification and Engineer Incharge of the work.b)Installation ---- etc., complete with all lead | No | 182.9 | 182.9 | 30.0 | False | None | None | False | None | False | 5487.0 | 0 | 3091509 | 106300 | None | code670 | Providing Core cutting up to 250 mm dia including packing after installation of suitable pipe in concrete/brick masonry surface.Complete with all lead & lift and work to be executed as per specification and Engineer Incharge of the work ---- etc., complete with all lead | Job | 2360.0 | 2360.0 | 15.0 | False | None | None | False | None | False | 35400.0 | 0 | 3091510 | 106300 | None | code671 | Providing Core cutting up to 250 mm dia including packing after installation of suitable pipe in concrete/brick masonry surface.Complete with all lead & lift and work to be executed as per specification and Engineer Incharge of the work ---- etc., complete with all lead | Job | 3844.44 | 3844.44 | 15.0 | False | None | None | False | None | False | 57666.6 | 0 | 3091511 | 106300 | None | code672 | DESIGN,SUPPLY ERECTION TESTING & COMISSIONING OF CLEAN ROOM SYSTEM -Providing and fixing 50 mm thick prefabricated walkable stainless steel panels ceiling The panel should have a composite construction of two skins, one side stainless steel 304 grade 0.8 mm thick and other side sheet is PPGI sheet of 0.6 mm thick. And these two sheets are held together with aluminum ‘w’ section of 48mm x 10.2mm for frame work & inner space between two sheets is filled with Puff insulation with density of 40Kg per Cubic meter. The panel size should be 1.20Mts x 3.00 Mtr. The stainless steel surface should be brush / MAT finish with antiglare property. The false ceiling panels are designed in such way that to fit within each other. There shall be minimum joints. If joints are necessary the panels will be jointed each other by using aluminum ‘H ‘ section 29 mm x 42 mm for interlock system. And all panel joints will be sealed by using compressible food grade silicon sealent to ensure air tight vapor tight construction. The false ceiling shall be walkable with provision of service panel. The false ceiling should be fixed to the concrete slab by using 8mm treaded tension bars with adjustable turn buckles, fastener, nuts, bolts etc., complete to the concrete slab.
Coving: Providing corner joint coving for wall to wall used to provide smooth and seamless corner coving buffed aluminium extruded profile R75 ‘C’ cap, L section profile, ‘Z’ section profile.
The required size cut outs for fixing of lights & also for any other services shall be made. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift and etc., complete. The works shall be carried out as per the directions of the Engineer in charge.
( Note: The panel should be free from scratches & dents )
MODULAR OT area -8 mtr X6 mtr apprxt.
Say 50.00 Sqm ---- etc., complete with all lead | Sqm | 10354.5 | 10354.5 | 200.0 | False | None | None | False | None | False | 2070900.0 | 0 | 3091512 | 106300 | None | code673 | Providing and fixing 50 mm thick prefabricated stainless steel wall panels. The panel should have a composite construction of two skins, one side stainless steel 304 grade 0.8 mm thick and other side sheet is PPGI sheet of 0.6 mm thick and these two sheets are held together with aluminum W section size 48mm x 10.2mm for frame work and inner space between two sheets is filled with Puff insulation with density of 40Kg per Cubic meter. The panel size should be 1.20Mts x 3.00 Mtr. The stainless steel surface should be brush / MAT finish with antiglare property. The wall panels are designed in such way that to fit within each other. There shall be minimum joints. If joints are necessary the panels will be jointed each other by using aluminum H section 29 mm x 42 mm for interlock system. And all panel joints will be sealed by using compressible food grade silicon to ensure air tight vapour tight construction. Coving:Providing corner joint coving used to provide smooth and seamless corner coving buffed Aluminium extruded profile R75 ‘C’ cap, L section profile, ‘Z’ section profile. The covings shall be provided wall to wall, wall to ceiling, wall to floor. The required size cut outs for fixing of control panel and switch plate shall be made. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge.
( Note: The panel should be free from scratches & dents )
6 mtr X 3 mtr X2 Nos. =36 Sqmtr
8 mtr X 3 mtr X2 Nos. =48 Sqmtr
Say 84.00 Sqm
( Door area will be detected form wall panel) ---- etc., complete with all lead | Sqm | 10354.5 | 10354.5 | 336.0 | False | None | None | False | None | False | 3479112.0 | 0 | 3091513 | 106300 | None | code674 | Supplying and Fixing STAINLESS STEEL DOOR Providing, fabrication and fixing of Stainless steel door with openable shutter of suitable size. The Door frame section of 50mm x 100mm size is made out of 1.2mm thick Stainless steel sheet of 304 grade. The door shutter of 42 - 45 mm thick by using 0.8mm thick stainless sheet of 304 grade for both sides and the surface of the steel should be MAT finish with antiglare property and having composite construction & the space b/w two sheets is filled with Puff insulation with 40 Kg/cum density shall be used to ensure air tight & vapour tight construction. Door shall be provided with automatic drop seal at bottom of door, sealed with high quality neoprene sealing gasket in all edges. The doors are provided with vision panel in double toughened glass size 300mm x 300mm,(6mm thick). All accessories including heavy duty SS ball bearing butt door hinges, SS 304 grade handles- 02 sets, heavy duty door closure, SS concealed Tower Bolt, etc are all approved make. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge.
Srub Door /Dirty utility Door (single leaf)
1 mtr X 2.10 mtr
Say 2.10 Sqmtr ---- etc., complete with all lead | Sqm | 53843.4 | 53843.4 | 8.4 | False | None | None | False | None | False | 452284.56 | 0 | 3091514 | 106300 | None | code675 | Supplying and Fixing HERMATICALLY SEALED STAINLESS STEEL SLIDING DOOR Providing, fabrication and fixing of manually operated hermetically sealed stainless steel sliding door of size1500 x 2100mm. The door shutter of 42 - 45 mm thick by using 0.8mm thick stainless sheet of 304 grade for both sides and the surface of the steel should be MAT finish with antiglare property and having composite construction & the space b/w two sheets is filled with Puff insulation with 40 Kg/cum density shall be used to ensure air tight & vapour tight construction. The sliding Door runs on Nylon wheel within an Aluminium extrusion high quality rail complete with required accessories. The door track is constructed from an aluminium extrusion, fixed firmly to the wall. Door shall be provided with automatic drop seal at bottom of door, sealed with high quality neoprene sealing gasket in all edges.
The doors are provided with vision panel in double toughened glass size 300mm x 300mm,(6mm thick). All accessories including SS 304 grade handles- 02 sets, SS concealed Tower Bolt, etc., Complete are all approved make. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge. ---- etc., complete with all lead | Sqm | 96585.36 | 96585.36 | 14.0 | False | None | None | False | None | False | 1352195.04 | 0 | 3091515 | 106300 | None | code676 | Antistatic Epoxy Flooring : Providing and laying 4mm thick anti-static, anti-fungal and anti-bacterial epoxy flooring after preparing the floor surface by removing all loose particles, dirt by using coir brush and vacuum cleaner. Applying one coat of Moisture barrier primer and then applying self-leveling 2mm thick moisture barrier layer to capture the moisture of the existing flooring. Then the anti static grid is laid with conductive granules and copper strips. Then apply one coat of epoxy based primer and allow for dry 6- 8 hours. Then apply epoxy putty and allow for dry 6 to 8 hours. And then apply 2 mm thick self-leveling epoxy flooring of approved make, colour and shade. The Epoxy flooring should be impact resistance, chemical resistance including abrasion and fumigation with R75mm coving wall to wall, wall to flooring etc., The cost includes cost of material, labour, transportation etc., complete. The works shall be carried out as per the directions of the Engineer in charge. ---- etc., complete with all lead | Sqm | 3835.0 | 3835.0 | 216.0 | False | None | None | False | None | False | 828360.0 | 0 | 3091516 | 106300 | None | code677 | Supplying and Fixingof 2'x2' LED recessed luminarie with…. Watts system wattage. Housing shall be with pressure die cast aluminium alloy with corrosion proof resistant polyester powder coated. Driver operates with voltage range from 100v to 270V 50/60 Hz with short circuit, overload & mis-wring protection. Lumen maintenance of 70% at 50000 Hrs. injection moulded poly carbonate diffuser for better mechanical stability, light transmission & avoid pot hole effect. Junction temperature shall be 70 degree Celsius. Driver is on constant current driver @ 0.06A with PF 0.9, line voltage @ 50Hz, driver efficiency 85% & THD15%. LED Efficiency 130 Im/W & Fixture Efficiency 75lm/w with CRI 75 with injection moulded Polycarbonate lens with 8mm depth. 5 years Warranty against any manufacturing defect working under standard electrical condition.] ---- etc., complete with all lead | Each | 9725.56 | 9725.56 | 32.0 | False | None | None | False | None | False | 311217.92 | 0 | 3091517 | 106300 | None | code678 | Supplying and Fixing LED - X-Ray Viewing Screen :X-RAY VIEWING SCREEN: - Two Plate X-Ray View Screen with flicker free illumination having imported LED system for uniform illumination and operated by X-ray film. The system having electrical safety codes for high & Low voltage system. The X ray viewing screen shall be concealed with wall panel. ---- etc., complete with all lead | Each | 33040.0 | 33040.0 | 4.0 | False | None | None | False | None | False | 132160.0 | 0 | 3091518 | 106300 | None | code679 | Supplying and Fixing Magnetic Writing List Board:Magnetic Writing Board of size 940 x 640 x 50 mm comprises of a flush mounted, 1.50 mm thick, white laminate board, bonded to a 10 mm high density fibre board sheet for additional rigidity. Magnetic Writing List Board shall be concealed with wall panel. ---- etc., complete with all lead | Each | 6903.0 | 6903.0 | 4.0 | False | None | None | False | None | False | 27612.0 | 0 | 3091519 | 106300 | None | code680 | Supply and installation of Stainless steel 304 grade Plenum LAMINAR FLOW- Plan air Ceiling mounted system with unidirectional airflow,(Air flow velocity of 25 to 35 FPM) Plenum unit, Holding structure & Top plenum are conforming to DIN 4799 / EU14 (Mini pleate HEPA filter) standards for the air distribution system complete with provision for 6 Nos. (Size 1220mmX610mmX90mm thick) HEPA Filters (efficiency 99.97% down to 0.3 micron ), 4000 cfm. The Plenum size is 1800 x 2400mm. The Diffuser is made out of SS 304 Grade material for laminar of filtered air. The complete unit will have factory prepared fine sealing system. It will be perfectly seamless. It will be made out of SS 304 Sheet of required thickness With perforated SS 304 sheet with etc., complete. ---- etc., complete with all lead | Each | 312700.0 | 312700.0 | 4.0 | False | None | None | False | None | False | 1250800.0 | 0 | 3091520 | 106300 | None | code681 | Supplying and Fixing STAINLESS STEEL STORAGE UNIT:Providing and supplying Storage Unit of size 800x1900x350 mm has made of 0.8.mm thick SS304 grade sheet. The exterior openable glass doors shall be made by using 6mm thick toughened glass with lockable & magnetic push-button for easy opening. Removable toughened glass shelves of thickness 6 mm will be provided with the storage units. ---- etc., complete with all lead | Each | 70800.0 | 70800.0 | 4.0 | False | None | None | False | None | False | 283200.0 | 0 | 3091521 | 106300 | None | code682 | Supplying and Fixing PASS/HATCH BOX:Providing and fixing Hatch box for modular OT in stainless steel SS 304, SS Handles, SS Hinges, View window, Door close/open indication, Electromagnetic door interlocking system based on Microcontroller electronic system for disposal of dirty linen/waste to non-sterile store.(Size 600mm x 600mm x 600mm) with double door inter lock and consisiting of UV lamp, UV lamp on for both door closed, UV lamp off for any door open, CF lamp on any door is open CF lamp off both door closed including cost of conceted accessories. ---- etc., complete with all lead | Each | 76700.0 | 76700.0 | 4.0 | False | None | None | False | None | False | 306800.0 | 0 | 3091522 | 106300 | None | code683 | Supplying and Fixing OT control Panel 6 Tile : Supply and installation of 6 tile OT control panel with distribution box, control panel will be mounted flush in the theatre wall, comprising of the following1. Medical gas card.2. Laminar Air flow controls Temperature & humidity indicators, filter status, temperature & humidity control..3. Digital elapsed timer.4. Hand free phone.5. Digital day timer clock.6. Lighting control panel. ---- etc., complete with all lead | Each | 129800.0 | 129800.0 | 4.0 | False | None | None | False | None | False | 519200.0 | 0 | 3091523 | 106300 | None | code684 | Providing & fixing SS304 grade return air grill. The cut out for return air grill size in panel is 600mmX450mm. The cost includes cost of material, labour charges for fixing etc complete. ---- etc., complete with all lead | Each | 4130.0 | 4130.0 | 16.0 | False | None | None | False | None | False | 66080.0 | 0 | 3091524 | 106300 | None | code685 | SUPPLY ERECTION TESTING & COMISSIONING of Return air riser made out of SS 304 grade with 18 SWG in the clean room area of 1000 CFM and provision for return air collar damper anf grill with all concted accessories. ---- etc., complete with all lead | Each | 21240.0 | 21240.0 | 16.0 | False | None | None | False | None | False | 339840.0 | 0 | 3091525 | 106300 | None | code686 | Supplying and Fixing Providing and making trap door of size 600 x 600mm in the ceiling panel by cutting. The required frame work shall be made by using Aluminium sections. The cost includes cost of material, labour charges for fixing etc complete. ---- etc., complete with all lead | Each | 7375.0 | 7375.0 | 4.0 | False | None | None | False | None | False | 29500.0 | 0 | 3091526 | 106300 | None | code687 | AHU's RECYCLE SYSTEM FOR OT AREA AS PER NABH NORMS -SUPPLY ERECTION TESTING & COMISSIONING Air handling units of GSS powder coated sheet metal cabinet type Double skin Recirculatory type 40-45 mm thick,Thermal break,modular construction.Air handling units shall be complete with Backward curved blower having capacity of 3500 t0 4000 cfm (Minimum 25 to 35 ACPH ) with 125 mm capacity, 3.75kw TEFC motor,fan motor drive filter section with 10 microns pre filter,3 microns fine filters, DX coil 6 row section of copper coil with aluminium fins,Mist eleminator, inlet and outlet volume control dampers and bypass dampers with access doors and accessories including 10% Fresh air with module with console type and grill, 20 Microns Fresh air filter. 10% Bleed module with hepa filter,damper and grille, View glass, View lamp, limit switch for door & Pressure port for filter sections & provision to fix pressure port to measure the pressure drop across the filter, ( EFF1 Motor ) coil should be 5. 5 TR x 2 circute with all concted accessories. ---- etc., complete with all lead | No | 597788.0 | 597788.0 | 4.0 | False | None | None | False | None | False | 2391152.0 | 0 | 3091527 | 106300 | None | code688 | AIR COOLED CONDENSER UNIT & COPPER PIPING-SUPPLY ERECTION TESTING & COMISSIONING 5.5 TR Air cooled out door condensing units comprising of semi -hermetic / hermetic reciprocating/scrool compressors with matching air cooled condenser suitable for 3500 to 4000 CFM AHU) provided with necessary controls.like Thermostart , Draier with MS painted stand ---- etc., complete with all lead | No | 146320.0 | 146320.0 | 8.0 | False | None | None | False | None | False | 1170560.0 | 0 | 3091528 | 106300 | None | code689 | GRILLE & DAMPER-SUPPLY ERECTION TESTING & COMISSIONING Collar damper made out of Al. with powder coated as per return air openinig size ---- etc., complete with all lead | Sqm | 10384.0 | 10384.0 | 8.0 | False | None | None | False | None | False | 83072.0 | 0 | 3091529 | 106300 | None | code690 | SUPPLY ERECTION TESTING & COMISSIONING Aluminium Volume control dampers manual operated, Only for hepa module, unit mouth & branch Ducts ---- etc., complete with all lead | Sqm | 13924.0 | 13924.0 | 8.0 | False | None | None | False | None | False | 111392.0 | 0 | 3091530 | 106300 | None | code691 | SUPPLY ERECTION TESTING & COMISSIONING Fire Dampers with Fusible Links rated for 72 C for AHU mouth, with fire damper actuator with inter link with AHU controll panel in case of fire AHU motor should stop. ---- etc., complete with all lead | No | 6254.0 | 6254.0 | 4.0 | False | None | None | False | None | False | 25016.0 | 0 | 3091531 | 106300 | None | code692 | SUPPLY ERECTION TESTING & COMISSIONING Fire retardant flexible connections for AHU supply & return air mouth ---- etc., complete with all lead | No | 5546.0 | 5546.0 | 8.0 | False | None | None | False | None | False | 44368.0 | 0 | 3091532 | 106300 | None | code693 | DUCTING & INSULATION-SUPPLY ERECTION TESTING & COMISSIONING Al. ducting including the supports,selicon sealent with painted MS angle flanges.22 guage ---- etc., complete with all lead | Sqm | 2006.0 | 2006.0 | 640.0 | False | None | None | False | None | False | 1283840.0 | 0 | 3091533 | 106300 | None | code694 | SUPPLY ERECTION TESTING & COMISSIONING Supply & return air duct Insulation with factory laminated Al. foil class 'O' grade.13 mm thk for return air duct ---- etc., complete with all lead | Sqm | 920.4 | 920.4 | 320.0 | False | None | None | False | None | False | 294528.0 | 0 | 3091534 | 106300 | None | code695 | SUPPLY ERECTION TESTING & COMISSIONING Supply & return air duct Insulation with factory laminated Al. foil class 'O' grade.19 mm thk for supply air duct ---- etc., complete with all lead | Sqm | 1097.4 | 1097.4 | 360.0 | False | None | None | False | None | False | 395064.0 | 0 | 3091535 | 106300 | None | code696 | Polishield covering with two coats paint for exposed duct ---- etc., complete with all lead | Sqm | 1038.4 | 1038.4 | 280.0 | False | None | None | False | None | False | 290752.0 | 0 | 3091536 | 106300 | None | code697 | SUPPLY & Fixing 300 dia Insulated flexible connection for grille module & return air raiser ---- etc., complete with all lead | Rmtr | 979.4 | 979.4 | 80.0 | False | None | None | False | None | False | 78352.0 | 0 | 3091537 | 106300 | None | code698 | 25 mm PVC dia drain piping with supports for AHUs ---- etc., complete with all lead | Rmtr | 625.4 | 625.4 | 200.0 | False | None | None | False | None | False | 125080.0 | 0 | 3091538 | 106300 | None | code699 | SUPPLY ERECTION TESTING & COMISSIONING Ele.controll panel inter lock with AHUs and 5.5 TR 2 nos condenser unit with TEMP. & RH Controller
For AHU ---- etc., complete with all lead | Set | 12272.0 | 12272.0 | 4.0 | False | None | None | False | None | False | 49088.0 | 0 | 3091539 | 106300 | None | code700 | SUPPLY ERECTION TESTING & COMISSIONING 4 Kw Ele. Heater with RH controller to controll humidity of 50 to 60% ---- etc., complete with all lead | Set | 66788.0 | 66788.0 | 4.0 | False | None | None | False | None | False | 267152.0 | 0 | 3091540 | 106300 | None | code701 | 4C X 6 Sqmm .Supplying and drawing flexble multicore cable manufactured with electroytic grade copper with flexible copper conductor confirming to table 3 class 5 of IS:8130-1984 and PVC insulation and sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 & confirming to GTP ---- etc., complete with all lead | m | 218.3 | 218.3 | 240.0 | False | None | None | False | None | False | 52392.0 | 0 | 3091541 | 106300 | None | code702 | 4C X 4 Sqmm .Supplying and drawing flexble multicore cable manufactured with electroytic grade copper with flexible copper conductor confirming to table 3 class 5 of IS:8130-1984 and PVC insulation and sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 & confirming to GTP ---- etc., complete with all lead | m | 177.0 | 177.0 | 240.0 | False | None | None | False | None | False | 42480.0 | 0 | 3091542 | 106300 | None | code703 | 4C X 2.5 Sqmm .Supplying and drawing flexble multicore cable manufactured with electroytic grade copper with flexible copper conductor confirming to table 3 class 5 of IS:8130-1984 and PVC insulation and sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 & confirming to GTP ---- etc., complete with all lead | m | 123.9 | 123.9 | 120.0 | False | None | None | False | None | False | 14868.0 | 0 | 3091543 | 106300 | None | code704 | 8C X 2.5 Sqmm S.R. .Supplying and drawing flexble multicore cable manufactured with electroytic grade copper with flexible copper conductor confirming to table 3 class 5 of IS:8130-1984 and PVC insulation and sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 & confirming to GTP ---- etc., complete with all lead | m | 348.1 | 348.1 | 120.0 | False | None | None | False | None | False | 41772.0 | 0 | 3091544 | 106300 | None | code705 | 4C X 10 Sqmm .Supplying and drawing flexble multicore cable manufactured with electroytic grade copper with flexible copper conductor confirming to table 3 class 5 of IS:8130-1984 and PVC insulation and sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 & confirming to GTP ---- etc., complete with all lead | m | 348.1 | 348.1 | 120.0 | False | None | None | False | None | False | 41772.0 | 0 | 3091545 | 106300 | None | code706 | SUPPLY & Fixing Cable trey-300 width x 50 ht perforated P. No.63 Item No.7.19.2 ---- etc., complete with all lead | Rmtr | 645.46 | 645.46 | 120.0 | False | None | None | False | None | False | 77455.2 | 0 | 3091546 | 106300 | None | code707 | Plate COpper Earthing strip 24 x 3 mm connected to existing earthing P.55 Item No.7.3.6 ---- etc., complete with all lead | Rmtr | 617.14 | 617.14 | 200.0 | False | None | None | False | None | False | 123428.0 | 0 | 3091547 | 106300 | None | code708 | SUPPLY & FIXING DP Gauge range 0 to 6 mm wg for OT room to monitoring positive pressure ---- etc., complete with all lead | Nos | 10089.0 | 10089.0 | 4.0 | False | None | None | False | None | False | 40356.0 | 0 | 3091548 | 106300 | None | code709 | DSUPPLY & FIXING DP Gauge range 0 to 50 mm wg for AHU & EAU pre & fine filter section to monitoring pressure drop in the filters ---- etc., complete with all lead | Nos | 9735.0 | 9735.0 | 8.0 | False | None | None | False | None | False | 77880.0 | 0 | 3091549 | 106300 | None | code710 | Supplying & Fixing Single Arm Rotating OT Pendant: Single ARM 320 Deg Rotating Anesthesia Pendant Complete with Electrical Outlets (8 Nos), Data Points (1 Nos) and Medical Gas Outlets (7 Nos), 1 Monitor Tray, 2 Nos. Shelfs, 2 Nos I V Stand ---- etc., complete with all lead | Nos | 194700.0 | 194700.0 | 4.0 | False | None | None | False | None | False | 778800.0 | 0 | 3091550 | 106300 | None | code711 | Supply , installation, testing and commissioning Double arm moveable pendant for surgeon with connected accessories.
The Pendants shall comply with NFPA 99C/HTM 02-01/DIN/EN/ISO 7396-1 as amended up to the last date of receipt of tenders. The support arms shall be extremely robust and revolve on high quality bearings, so that the pendant head glides smoothly and quickly to any desired position.
Double moveable arms (any combination) with total coverage of min 1800 mm and minimum 330 Each arm shall have ability of horizontal movement. Vertical movement shall be motorized and the arm height shall remain at a height greater than 6.5 feet above floor level.
Weight carrying capacity of the arm shall not be less than 180 Kg. It shall have electromagnetic/pneumatic brakes.
Each arm shall be capable of minimum 330 of rotation, which can be easily adjusted to suit the desired mode of operation.
The pendant shall be European CE Certified with 4 digit notified body number/US FDA/ETL/UL/BIS certified/listed under medical devices directive.
The Pendant Service Heads shall be modular with minimum 800mm head.The heads shall be capable of accepting a range of shelves, infusion poles, electrical switch/sockers, gas outlets and other required accessories. The Pendant Heads shall support the range of Physiological Monitor Mounting Solutions.
The Pendant Service Heads shall be supplied with medical gas terminal units and 5A/15A or 6A/16 A hybrid sockets.
Pendant shall be supplied with outlets and probes as mentioned below.
Oxygen Outlets -2 nos , Medical Air Outlets 4 bar -1 no,Vacuum Outlets -2 nos
,Air(7bar) outlets-01 no, CO2 outlets-01 nos, Electrical Sockets-10 no, Adjustable shelf with two rails one on each side -3 no, Data socket RJ-45 -2 nos, IV Fluid Pole with 2 hooks -1 no, (Pole shall be capable of stacking 4 syringe pumps), Nitrous oxide outlets-1 no.
Pendent shall provide cut-outs for patch panel in integrated OTs (only for integrated OTs.)
Surgeon pendant shall have NIST connection for all gases to conncet the MGPLS system. ---- etc., complete with all lead | Nos | 430700.0 | 430700.0 | 4.0 | False | None | None | False | None | False | 1722800.0 | 0 | 3091551 | 106300 | None | code712 | Scrub Station
MOT SCRUB STATION (minimum size 1500 mm)
supply , installation and commissioning of compact surgical scrub sink shall be designed for use in OT area for pre-procedural scrub. Double sink combination shall be provided. Fabricated from heavy gauge type 304 stainless steel (minimum thicknes 1.5 mm) and shall be of seamless welded construction, polished to a satin finish.With a front access panel which shall be easily removable for access to the water controlled valve, waste connections, stoppers and strainers. Hands free operation shall include infra-red sensors with programmable adjustment. .Thermostatic mixing, valve control shall be located behind the access panel and it shall maintain constant water temperature.Timing shall be adjustable to meet individual application requiements.(built in with timer setting from 1 to 10 mic)It shall be provided with infrared sensors, thermostatic control taps with fail safe temprerature controls. All units shall have reduced anti-splash fronts.Knee/foot operated switch shall be provided additionally with all connected accessories. ---- etc., complete with all lead | Nos | 278480.0 | 278480.0 | 4.0 | False | None | None | False | None | False | 1113920.0 | 0 | 3091552 | 106300 | None | code713 | Supply , installation, testing and commissioning OT surgical Lighting system with connected accessroies
MOT surgical lighting system shall provide an ideal combination of brightness, manoeuvrability and shadow resolution without sacrificing colour and accuracy through a consistent LED technology.
Such lighting system shall have the following technical specifications:
a) Number of light heads : Two
b) Rotation system : 360
c) Colour temperature range : 3800 K to 5000 K (10%)-variable colour temperature.
d) +/-CRI : 93 Ra.
e) LED's : Low temp . 3 Colours combination.
f) LED bulb life : 50,000 hrs.
g) Field size diameter : 20 to 28 cm (+/-10%)
h) Working range : 750 to 1100 mm (+/-10%)
i) Focus : Adjustable 100mm-250mm.
j) Illumination leve l: minimum 160,000 lux (both for major dome and minor dome separately).
k) Controls : control panel ( two:one on the wall and other on dome/ digital with wireless remote).
l) Power supply : 220 V/ 50Hz AC. ---- etc., complete with all lead | Nos | 413118.0 | 413118.0 | 4.0 | False | None | None | False | None | False | 1652472.0 | 0 | 3091553 | 106300 | None | code714 | CSSD-Steri- MacA-80 Fully Automated ETO machine ---- etc., complete with all lead | Nos | 2999619.0 | 2999619.0 | 2.0 | False | None | None | False | None | False | 5999238.0 | 0 | 3091554 | 106300 | None | code715 | CSSD-1’ X 1’ X 3’ (ft.) internal Size ---- etc., complete with all lead | Nos | 1162890.0 | 1162890.0 | 1.0 | False | None | None | False | None | False | 1162890.0 | 0 | 3091555 | 106300 | None | code716 | CSSD-Medical Ultrasonic Cleaner 50 ltrs ---- etc., complete with all lead | Nos | 375470.1 | 375470.1 | 1.0 | False | None | None | False | None | False | 375470.1 | 0 | 3091556 | 106300 | None | code717 | CSSD-Drying Cabinet 100 Liters ---- etc., complete with all lead | Nos | 342495.0 | 342495.0 | 1.0 | False | None | None | False | None | False | 342495.0 | 0 | 3091557 | 106300 | None | code718 | CSSD-Rinsing Cabinet 100ltrs ---- etc., complete with all lead | Nos | 342495.0 | 342495.0 | 1.0 | False | None | None | False | None | False | 342495.0 | 0 | 3091558 | 106300 | None | code719 | CSSD-Sealer ---- etc., complete with all lead | Nos | 50976.0 | 50976.0 | 2.0 | False | None | None | False | None | False | 101952.0 | 0 | 3091559 | 106300 | None | code720 | CSSD-Air Gun + Water Gun ---- etc., complete with all lead | Nos | 7965.0 | 7965.0 | 6.0 | False | None | None | False | None | False | 47790.0 | 0 | 3091560 | 106300 | None | code721 | CSSD-Flash Sterilizer 35ltrs ---- etc., complete with all lead | Nos | 1911600.0 | 1911600.0 | 1.0 | False | None | None | False | None | False | 1911600.0 | 0 | 3091561 | 106300 | None | code722 | CSSD Furnitures - Tables 4, Storage racks 4 ---- etc., complete with all lead | Nos | 1223424.0 | 1223424.0 | 1.0 | False | None | None | False | None | False | 1223424.0 | 0 | 3091562 | 106300 | None | code723 | Aluminum Modular Signage using Aluminum alloy 6063 extrusion with Anodizing (thickness typically to be 30 microns. The integrity to meet international specifications ISO 2143-1981) with life time warranty in normal working conditions. Clear Cover : Clear UV protected 1mm thick Poly carbonate sheet with non Glare/glossy finish. Size - 210 X 700. Driveway ---- etc., complete with all lead | No | 4484.0 | 4484.0 | 10.0 | False | None | None | False | None | False | 44840.0 | 0 | 3091563 | 106300 | None | code724 | Acrylic Signage ---- etc., complete with all lead | No | 472.0 | 472.0 | 439.0 | False | None | None | False | None | False | 207208.0 | 0 | 3091564 | 106300 | None | code725 | 5mm Sunboard with UV Printing fixed with double sided tape and mirror screws ---- etc., complete with all lead | No | 826.0 | 826.0 | 30.0 | False | None | None | False | None | False | 24780.0 | 0 | 3091565 | 106300 | None | code726 | SS Acid etching ---- etc., complete with all lead | No | 1321.6 | 1321.6 | 502.0 | False | None | None | False | None | False | 663443.2 | 0 | 3091566 | 106300 | None | code727 | Aluminum Modular Signage using Aluminum alloy 6063 extrusion with Anodizing (thickness typically to be 30 microns. The integrity to meet international specifications ISO 2143-1981) with life time warranty in normal working conditions. Clear Cover : Clear UV protected 1mm thick Poly carbonate sheet with non Glare/glossy finish. Size - 50 X 200. Driveway ---- etc., complete with all lead | No | 1770.0 | 1770.0 | 60.0 | False | None | None | False | None | False | 106200.0 | 0 | 3091567 | 106300 | None | code728 | 5MM Sunboard with vinyl ---- etc., complete with all lead | No | 1770.0 | 1770.0 | 258.0 | False | None | None | False | None | False | 456660.0 | 0 | 3091568 | 106300 | None | code729 | Stencil Painting enamel with double coat of primer and putty - 900 X 900. Column Top ---- etc., complete with all lead | No | 2124.0 | 2124.0 | 80.0 | False | None | None | False | None | False | 169920.0 | 0 | 3091569 | 106300 | None | code730 | SS Acid etching stuck on Acrylic ---- etc., complete with all lead | No | 2242.0 | 2242.0 | 383.0 | False | None | None | False | None | False | 858686.0 | 0 | 3091570 | 106300 | None | code731 | Acrylic Signage ---- etc., complete with all lead | No | 2950.0 | 2950.0 | 44.0 | False | None | None | False | None | False | 129800.0 | 0 | 3091571 | 106300 | None | code732 | 5MM Sunboard with vinyl ---- etc., complete with all lead | No | 2950.0 | 2950.0 | 40.0 | False | None | None | False | None | False | 118000.0 | 0 | 3091572 | 106300 | None | code733 | Acrylic A4 size inserts ---- etc., complete with all lead | No | 2950.0 | 2950.0 | 24.0 | False | None | None | False | None | False | 70800.0 | 0 | 3091573 | 106300 | None | code734 | 50mm Square Aluminium with reflective tapes and painted red and black. Dimensions as per site conditions ---- etc., complete with all lead | No | 4130.0 | 4130.0 | 2.0 | False | None | None | False | None | False | 8260.0 | 0 | 3091574 | 106300 | None | code735 | Aluminum Modular Signage using Aluminum alloy 6063 extrusion with Anodizing (thickness typically to be 30 microns. The integrity to meet international specifications ISO 2143-1981) with life time warranty in normal working conditions. Clear Cover : Clear UV protected 1mm thick Poly carbonate sheet with non Glare/glossy finish. Size - 210 X 700 ---- etc., complete with all lead | No | 4484.0 | 4484.0 | 124.0 | False | None | None | False | None | False | 556016.0 | 0 | 3091575 | 106300 | None | code736 | SS Acid etching ---- etc., complete with all lead | No | 8850.0 | 8850.0 | 16.0 | False | None | None | False | None | False | 141600.0 | 0 | 3091576 | 106300 | None | code737 | 3D Aluminium Channel Letter ---- etc., complete with all lead | No | 9145.0 | 9145.0 | 36.0 | False | None | None | False | None | False | 329220.0 | 0 | 3091577 | 106300 | None | code738 | SS Acid etching ---- etc., complete with all lead | No | 9145.0 | 9145.0 | 30.0 | False | None | None | False | None | False | 274350.0 | 0 | 3091578 | 106300 | None | code739 | Acid Etching on SS fixed on Acrylic ---- etc., complete with all lead | No | 10030.0 | 10030.0 | 24.0 | False | None | None | False | None | False | 240720.0 | 0 | 3091579 | 106300 | None | code740 | Aluminum Modular Signage using Aluminum alloy 6063 extrusion with Anodizing (thickness typically to be 30 microns. The integrity to meet international specifications ISO 2143-1981) with life time warranty in normal working conditions. Clear Cover : Clear UV protected 1mm thick Poly carbonate sheet with non Glare/glossy finish. Size - 600 X 900. Entry / Exit Points ---- etc., complete with all lead | No | 14750.0 | 14750.0 | 4.0 | False | None | None | False | None | False | 59000.0 | 0 | 3091580 | 106300 | None | code741 | Acid Etching on SS fixed on Acrylic ---- etc., complete with all lead | No | 15104.0 | 15104.0 | 22.0 | False | None | None | False | None | False | 332288.0 | 0 | 3091581 | 106300 | None | code742 | 3D 40mm SS Mirror Finish channel letters - Non Lit ---- etc., complete with all lead | No | 26550.0 | 26550.0 | 76.0 | False | None | None | False | None | False | 2017800.0 | 0 | 3091582 | 106300 | None | code743 | Aluminum Modular Signage using Aluminum alloy 6063 extrusion with Anodizing (thickness typically to be 30 microns. The integrity to meet international specifications ISO 2143-1981) with life time warranty in normal working conditions. Clear Cover : Clear UV protected 1mm thick Poly carbonate sheet with non Glare/glossy finish. Size - 600 X 1800. Entry and Exit ---- etc., complete with all lead | No | 41890.0 | 41890.0 | 2.0 | False | None | None | False | None | False | 83780.0 | 0 | 3091583 | 106300 | None | code744 | Aluminum Modular Signage using Aluminum alloy 6063 extrusion with Anodizing (thickness typically to be 30 microns. The integrity to meet international specifications ISO 2143-1981) with life time warranty in normal working conditions. Clear Cover : Clear UV protected 1mm thick Poly carbonate sheet with non Glare/glossy finish. Size - 900 X 2400. Drop off Points ---- etc., complete with all lead | No | 61950.0 | 61950.0 | 4.0 | False | None | None | False | None | False | 247800.0 | 0 | 3091584 | 106300 | None | code745 | 3D Acrylic Channel letters - 100mm thick - internally lit with LEDs ---- etc., complete with all lead | No | 65372.0 | 65372.0 | 2.0 | False | None | None | False | None | False | 130744.0 | 0 | 3091585 | 106300 | None | code746 | Aluminum Modular Signage using Aluminum alloy 6063 extrusion with Anodizing (thickness typically to be 30 microns. The integrity to meet international specifications ISO 2143-1981) with life time warranty in normal working conditions. Clear Cover : Clear UV protected 1mm thick Poly carbonate sheet with non Glare/glossy finish. Size - 1200 X 3600. IN THE CAMPUS ---- etc., complete with all lead | No | 112572.0 | 112572.0 | 2.0 | False | None | None | False | None | False | 225144.0 | 0 | 3091586 | 106300 | None | code747 | 3D Acrylic Channel letters - 100mm thick - internally lit with LEDs ---- etc., complete with all lead | No | 147972.0 | 147972.0 | 2.0 | False | None | None | False | None | False | 295944.0 | 0 | 3091587 | 106300 | None | code748 | 3D 40mm SS Mirror Finish channel letters - Non Lit ---- etc., complete with all lead | No | 187030.0 | 187030.0 | 5.0 | False | None | None | False | None | False | 935150.0 | 0 | 3091588 | 106300 | None | code749 | Aluminum Modular Signage using Aluminum alloy 6063 extrusion with Anodizing (thickness typically to be 30 microns. The integrity to meet international specifications ISO 2143-1981) with life time warranty in normal working conditions. Clear Cover : Clear UV protected 1mm thick Poly carbonate sheet with non Glare/glossy finish. Size - 12' X 18' ---- etc., complete with all lead | No | 218713.0 | 218713.0 | 4.0 | False | None | None | False | None | False | 874852.0 | 0 | 3091589 | 106300 | None | code750 | 3D 90mm Thick SS Mirror finish gold channel letters internally illuminated with LEDs and fixed directly on the surface- Dimensions as per site conditions ---- etc., complete with all lead | No | 265972.0 | 265972.0 | 3.0 | False | None | None | False | None | False | 797916.0 | 0 | 3091590 | 106300 | None | code751 | Aluminum Modular Signage using Aluminum alloy 6063 extrusion with Anodizing (thickness typically to be 30 microns. The integrity to meet international specifications ISO 2143-1981) with life time warranty in normal working conditions. Clear Cover : Clear UV protected 1mm thick Poly carbonate sheet with non Glare/glossy finish. Size - 210 X 700. ON THE BUILDING ---- etc., complete with all lead | No | 419726.0 | 419726.0 | 3.0 | False | None | None | False | None | False | 1259178.0 | 0 | 3091591 | 106300 | None | code752 | BAR SCREEN :
MS FRP Bar Screen made up of Mild steel coated with Enamel, Bar Screen Diemesion:1000x1000 - Length :1000 mm, Width :1000 mm, Mild steel sheet Thickness: 3mm, inlet nozzel Dia :6 , out let nozzel Dia: 6 Bar Screen Size : 10mm,screen MOC : Mild Steel, Screen coating :Enamel , Make : ORION ---- etc., complete with all lead | Set | 64900.0 | 64900.0 | 1.0 | False | None | None | False | None | False | 64900.0 | 0 | 3091592 | 106300 | None | code753 | RAW SEWAGE TRANSFER PUMP
Raw Sewage transfer pump capable of handling, sewage transfer from collection tank to RBC STP Tank ,The type of the pump : Centrifugal monoblock, Impeller :open, motor HP: 3HP and RPM:2870 , Flow Rate: 27 m3/hr, Head:15,Moc : Cl, solid Particle Size Handling: 7 mm
A).Valve : Suction : 2 nos,Delivery : 2 nos,Suction Size :50 mm, Delivery Size : 50 mm ,Moc : CI
B).Type : Ball /Butterfly, Non Return Valve, Delivery : 2 nos, Suction Size :50 mm, Delivery Size : 50 mm , Moc : CI
Make : Kriloskar / CRI, Pump (1 w + 1S) 2nos of pump = 1 set. ---- etc., complete with all lead | Set | 177000.0 | 177000.0 | 1.0 | False | None | None | False | None | False | 177000.0 | 0 | 3091593 | 106300 | None | code754 | STP Rectangular Tank Size and dimension: Length :14350 mm, Width : 1900 mm, Over Height including Top Cover : 3300 mm, MOC of rectangular Tank : Mild Steel - FRP, Shell Thickness: 5mm, FRP lining, Internal Lining : 3 mm, External Lining : 3 mm, Pipe inlet Dia: 80 mm, Pipe Outlet Dia: 150 mm, Drain Header pipe Dia: 80 mm No of Tank : 2 Nos, Make: ORION. ---- etc., complete with all lead | Set | 2900253.56 | 2900253.56 | 1.0 | False | None | None | False | None | False | 2900253.56 | 0 | 3091594 | 106300 | None | code755 | Primary clarifier : Type : Lamella, No of Plates: 40, Lamella plate MOC: FRP, Lemella Plate Thickness: 1 mm ,Make: ORION. ---- etc., complete with all lead | Set | 1077340.0 | 1077340.0 | 1.0 | False | None | None | False | None | False | 1077340.0 | 0 | 3091595 | 106300 | None | code756 | Secondary clarifier: Type : Lamella, No of Plates: 40, Lamella plate MOC: FRP, Lemella Plate Thickness: 1 mm Make: ORION. ---- etc., complete with all lead | Set | 1077340.0 | 1077340.0 | 1.0 | False | None | None | False | None | False | 1077340.0 | 0 | 3091596 | 106300 | None | code757 | ROTOR: No of Rotors: 6 per tank , Moc: FRP, Diameter of Rotor : 1250mm, Connected with , Shaft : 80 Rod, Driven by : pillar Block, No of pillar block: 24 Make: ORION ---- etc., complete with all lead | Set | 985300.0 | 985300.0 | 1.0 | False | None | None | False | None | False | 985300.0 | 0 | 3091597 | 106300 | None | code758 | Bio Zone (Rotor Placement Boat) No. of Biozone : 2 No, No. of Partisian inside Bio-zone : 8 Nos, MOC : MSFRP, Boat curvature Diameter : 1500mm, Bio Zone supporting with 150mm, Beam 2 Nos & 4 Nos. Legs., Make: ORION. ---- etc., complete with all lead | Set | 1087960.0 | 1087960.0 | 1.0 | False | None | None | False | None | False | 1087960.0 | 0 | 3091598 | 106300 | None | code759 | Gear Box : Type: Helical, No of Gear Box: 1 no, Make : Bonfigoli (Germany), Gear Box Motor HP: 5, Gear Box motor Make : ABB./eqv ---- etc., complete with all lead | Set | 177000.0 | 177000.0 | 1.0 | False | None | None | False | None | False | 177000.0 | 0 | 3091599 | 106300 | None | code760 | Internal Piping & Base Works : 1) Inter connecting pipe works with FRP lining inside process tank, Recirculion& drain system. 2)Base Plate works for Gear box arrangement,Rotor Fixing arrangement,Biozone leg placement arrangement. RBC STP Make : ORION. ---- etc., complete with all lead | Set | 338660.0 | 338660.0 | 1.0 | False | None | None | False | None | False | 338660.0 | 0 | 3091600 | 106300 | None | code761 | FILTER FEED PUMP: Filter feed pump capable of handling to transfer clarifed to filtration plant maximum solid handling size upto 7 mm, The type of the pump: Centrifugal monoblock, Impeller : Closed motor HP:7.5Hp and RPM: 2900, Flow Rate: 81.25 m3/hr, Head:30, Moc : solid Particle Size Handling: 7mm Valve , Suction : 2 nos, Delivery : 2 nos, Suction Size :100mm, Delivery Size : 100 mm, Moc : CI, Type : Ball /Butterfly, Non Return Valve, Delivery : 2 nos, Suction Size :100 mm, Delivery Size : 100 mm, Moc : CI, Make : Kriloskar / CRI, Pump (1 w + 1S) 2nos of pump = 1 set . ---- etc., complete with all lead | Set | 79060.0 | 79060.0 | 1.0 | False | None | None | False | None | False | 79060.0 | 0 | 3091601 | 106300 | None | code762 | SAND FILTER : Diameter: 1800 mm, Height On Straight: 1900 mm, Shell hickness: 5mm, Dish end Thickness: 5mm, Frontal Pipeline: 80NB, MOC: Mild Steel, External Coating : Red Oxide and Enamel paint, Internal Coating: Black Bitumus, Filter Media: Fine Sand, Gravel sand, pebbles, silex, Media in Kg: 4000, Media Depth : 915 mm, Type : Cylindrical, Vertical. Make: ORION. ---- etc., complete with all lead | Set | 443680.0 | 443680.0 | 1.0 | False | None | None | False | None | False | 443680.0 | 0 | 3091602 | 106300 | None | code763 | ACTIVATED CARBON FILTER: Diameter: 1800 mm,Height On Straight: 1900 mm, Shell hickness: 5mm,Dish end Thickness : 5 mm, Frontal Pipeline: 80NB, MOC: Mild Steel, External Coating :Red Oxide and Enamel paint,Internal Coating: Black Bitumus,Filter Media: Activated Carbon Media in Kg: 1400, Media Depth : 1000 mm,Type : Cylindrical, Vertical. Make: ORION. ---- etc., complete with all lead | Set | 443680.0 | 443680.0 | 1.0 | False | None | None | False | None | False | 443680.0 | 0 | 3091603 | 106300 | None | code764 | CHLORINE DOSING SYSTEM, Pump type : ElectonicDiaphram
Capacity : 0- 10LPH, Nominal Back pressure : 5 Kg/Sq Cm, Maximum Back pressure: 3.5 Kg/Sq Cm
KW: 0.24 watt, Tank Capacity : 200 Liters, MOC: PP, Make : Milton Roy/ Eqv ---- etc., complete with all lead | Set | 41300.0 | 41300.0 | 1.0 | False | None | None | False | None | False | 41300.0 | 0 | 3091604 | 106300 | None | code765 | INTERCONNECTING PIPE WORK All necessary pipe work from Bar Screen chamber to collection tank, collection tank to Raw sewage transfer pump, Raw sewage transfer pump to RBC STP, RBC STP to Filter feed pump, Filter feed pump to Filtration plant and filtration plant to treated water tank The scope shall be UPVC pipes with all necessary valves, NRV and drain Header. ---- etc., complete with all lead | Set | 404740.0 | 404740.0 | 1.0 | False | None | None | False | None | False | 404740.0 | 0 | 3091605 | 106300 | None | code766 | CONTROL PANEL: Installation, testing and commissioning of Electrical Panel suitable for 415V, 3 phase, 4 wire, 50Hz distribution system. The panel shall be Wall Mounting type, sheet metal enclosed, flush front with aluminium busbars, separate earth bus shall be provided throughout the length of the panel. The incoming and the outgoing feeder breakers, switch fuse units, change over switches, indicating lamps, meters etc. shall be accommodated in a modular multi-tier arrangement. The painting shall be done in conformity with IS code. Adequate size cable alley shall be provided all around the panel and at the back for easy bending and terminations. The outgoing feeders inside the panel shall be connected through solid busbars. Busbars shall be provided with UPVC heat shrinkable sleeves or heat resistant insulated paint. The panels shall be suitable for cable entry from top / bottom. ---- etc., complete with all lead | Set | 295000.0 | 295000.0 | 1.0 | False | None | None | False | None | False | 295000.0 | 0 | 3091606 | 106300 | None | code767 | FREIGHT LOADING AND UNLOADING : All the equipment shall be loaded ,transported and unloaded at site. Including the necessary Cranes required to erect and position the system ---- etc., complete with all lead | Set | 177000.0 | 177000.0 | 1.0 | False | None | None | False | None | False | 177000.0 | 0 | 3091607 | 106300 | None | code768 | INSTALLATION, ERECTION, COMMISSIONING, TESTING AND HANDING OVER AT SITE. From the Inlet of the Bar Screen chamber to the output of Carbon filter ---- etc., complete with all lead | Set | 235742.76 | 235742.76 | 1.0 | False | None | None | False | None | False | 235742.76 | 0 | 3091608 | 106300 | None | code769 | Bar Screen with 20 mm spacing ,MOC: MSEP,Make: Hydrodrops ---- etc., complete with all lead | Nos | 8260.0 | 8260.0 | 1.0 | False | None | None | False | None | False | 8260.0 | 0 | 3091609 | 106300 | None | code770 | Raw Effluent Transfer pumps,Duty:5cum/hr @ 10 m head,Type :Horizontal , centrifugal,MOC:PP,Make: Anala/Equiv ---- etc., complete with all lead | Nos | 41300.0 | 41300.0 | 2.0 | False | None | None | False | None | False | 82600.0 | 0 | 3091610 | 106300 | None | code771 | Sludge Transfer pumps ,Duty:5cum/hr @ 10 m head.Type :Horizontal , centrifugal,MOC:PP,Make: Anala/Equiv ---- etc., complete with all lead | No | 29500.0 | 29500.0 | 1.0 | False | None | None | False | None | False | 29500.0 | 0 | 3091611 | 106300 | None | code772 | SS Agitator,SS Agiatator with gearbox and motor as requried for flocculation ---- etc., complete with all lead | No | 112100.0 | 112100.0 | 1.0 | False | None | None | False | None | False | 112100.0 | 0 | 3091612 | 106300 | None | code773 | Dosing pumps for chemical dosing,Capacity: 0-6 lph,MOC: PP ,Make: Positive/Ant/Equiv ---- etc., complete with all lead | No | 20650.0 | 20650.0 | 3.0 | False | None | None | False | None | False | 61950.0 | 0 | 3091613 | 106300 | None | code774 | Inter unit piping ---- etc., complete with all lead | No | 53100.0 | 53100.0 | 1.0 | False | None | None | False | None | False | 53100.0 | 0 | 3091614 | 106300 | None | code775 | Electrical panel and cabling works ---- etc., complete with all lead | Lot | 53100.0 | 53100.0 | 1.0 | False | None | None | False | None | False | 53100.0 | 0 | 3091615 | 106300 | None | code776 | Treated Water Disposal pumps ,Duty:5cum/hr @ 10 m head ,Type :Horizontal , centrifugal,MOC:PP,Make: Anala/Equiv ---- etc., complete with all lead | Nos | 29500.0 | 29500.0 | 2.0 | False | None | None | False | None | False | 59000.0 | 0 | 3091616 | 106300 | None | code777 | Erection & Commissioning of STP of 500 KLD ---- etc., complete with all lead | LS | 88500.0 | 88500.0 | 1.0 | False | None | None | False | None | False | 88500.0 | 0 | 3091617 | 106300 | None | code779 | Preparation of Structural design and drawings as per I.S Codes including proof checking by reputed Government/Semi Government/IISC as decided by the Department and the same has to be furnished to the Department for approval and also Preparation of Architectural designs, Drawings and Elevations floor wise, preparation of internal and external Electrical works schematic drawings and working drawings ,public health engineering ,fire fighting, HVAC, MGPS, Furnishing ,CCTV, network system, UPS system, Nurse call system, Public address, TV System, bio medical waste system, roads drains acoustic treatment, landscaping, rain water harvesting, sewage treatment plant working drawings etc. and any other drawings related to this project. (6 sets of as built drawings shall be submitted to the employer) Note - All required service GFC drawings required for completion of projects. ---- -- ---- etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead | Job | 14500000.0 | 14500000.0 | 1.0 | False | None | None | False | None | False | 14500000.0 | 0 | 3091618 | 106300 | None | code780 | Construction of platforms as per design including earth work excavation, PCC, RCC, steel reinforcement & finishing works for installing the container ICU's, Shifting of Container ICU by crane & lifts, including transportation, installation, labours, materials machineries & providing all utilities like electrification, water supply & sanitary, MGPLS, oxygen lines , HVAC, & other allied works as per the direction of engineer incharge of the works to complete the shifting & running condition of container ICU's. ---- etc., complete with all lead | Unit | 1056100.0 | 1056100.0 | 10.0 | False | None | None | False | None | False | 10561000.0 | 0 |
| 1710501218000 | 0 | None | None | Buildings | Electrical Works | 179544873.74 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3091619 | 106301 | None | code01 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet. Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete with all lead | Point | 349.16 | 349.16 | 479.0 | False | None | None | False | None | False | 167247.64 | 0 | 3091620 | 106301 | None | code02 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete with all lead | Point | 491.94 | 491.94 | 896.0 | False | None | None | False | None | False | 440778.24 | 0 | 3091621 | 106301 | None | code03 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete with all lead | Point | 720.39 | 720.39 | 1822.0 | False | None | None | False | None | False | 1312550.58 | 0 | 3091622 | 106301 | None | code04 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches ---- etc., complete with all lead | Point | 878.75 | 878.75 | 286.0 | False | None | None | False | None | False | 251322.5 | 0 | 3091623 | 106301 | None | code05 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet. Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switches ---- etc., complete with all lead | Point | 1283.72 | 1283.72 | 154.0 | False | None | None | False | None | False | 197692.88 | 0 | 3091624 | 106301 | None | code06 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2Way ---- etc., complete with all lead | Each | 179.12 | 179.12 | 1876.0 | False | None | None | False | None | False | 336029.12 | 0 | 3091625 | 106301 | None | code07 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3Way ---- etc., complete with all lead | Each | 206.38 | 206.38 | 2099.0 | False | None | None | False | None | False | 433191.62 | 0 | 3091626 | 106301 | None | code08 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way ---- etc., complete with all lead | Each | 229.75 | 229.75 | 470.0 | False | None | None | False | None | False | 107982.5 | 0 | 3091627 | 106301 | None | code09 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way ---- etc., complete with all lead | Each | 285.56 | 285.56 | 639.0 | False | None | None | False | None | False | 182472.84 | 0 | 3091628 | 106301 | None | code10 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way ---- etc., complete with all lead | Each | 338.78 | 338.78 | 335.0 | False | None | None | False | None | False | 113491.3 | 0 | 3091629 | 106301 | None | code11 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete with all lead | Each | 414.06 | 414.06 | 225.0 | False | None | None | False | None | False | 93163.5 | 0 | 3091630 | 106301 | None | code12 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module ---- etc., complete with all lead | Each | 177.83 | 177.83 | 1811.0 | False | None | None | False | None | False | 322050.13 | 0 | 3091631 | 106301 | None | code13 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 Module ---- etc., complete with all lead | Each | 208.98 | 208.98 | 2099.0 | False | None | None | False | None | False | 438649.02 | 0 | 3091632 | 106301 | None | code14 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module ---- etc., complete with all lead | Each | 227.15 | 227.15 | 515.0 | False | None | None | False | None | False | 116982.25 | 0 | 3091633 | 106301 | None | code15 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module ---- etc., complete with all lead | Each | 303.73 | 303.73 | 660.0 | False | None | None | False | None | False | 200461.8 | 0 | 3091634 | 106301 | None | code16 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- etc., complete with all lead | Each | 368.63 | 368.63 | 365.0 | False | None | None | False | None | False | 134549.95 | 0 | 3091635 | 106301 | None | code17 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module ---- etc., complete with all lead | Each | 446.51 | 446.51 | 297.0 | False | None | None | False | None | False | 132613.47 | 0 | 3091636 | 106301 | None | code18 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc., complete with all lead | Each | 132.4 | 132.4 | 5074.0 | False | None | None | False | None | False | 671797.6 | 0 | 3091637 | 106301 | None | code19 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch ---- etc., complete with all lead | Each | 215.47 | 215.47 | 67.0 | False | None | None | False | None | False | 14436.49 | 0 | 3091638 | 106301 | None | code20 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- etc., complete with all lead | Each | 221.96 | 221.96 | 1768.0 | False | None | None | False | None | False | 392425.28 | 0 | 3091639 | 106301 | None | code21 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. ---- etc., complete with all lead | Each | 463.39 | 463.39 | 598.0 | False | None | None | False | None | False | 277107.22 | 0 | 3091640 | 106301 | None | code22 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc., complete with all lead | Each | 423.15 | 423.15 | 149.0 | False | None | None | False | None | False | 63049.35 | 0 | 3091641 | 106301 | None | code23 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- etc., complete with all lead | Each | 306.33 | 306.33 | 1395.0 | False | None | None | False | None | False | 427330.35 | 0 | 3091642 | 106301 | None | code24 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch ---- etc., complete with all lead | Each | 233.64 | 233.64 | 1973.0 | False | None | None | False | None | False | 460971.72 | 0 | 3091643 | 106301 | None | code25 | Supplyin and Fixing Metal Fan Box with Round Hook. ---- etc., complete with all lead | No | 151.87 | 151.87 | 468.0 | False | None | None | False | None | False | 71075.16 | 0 | 3091644 | 106301 | None | code26 | Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB).The entire plug and socket shall be mounted in a thermoplastic I powder coated metal box & wired Completely. SP & N 20Amps ---- etc., complete with all lead | Each | 1260.36 | 1260.36 | 70.0 | False | None | None | False | None | False | 88225.2 | 0 | 3091645 | 106301 | None | code27 | Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB).The entire plug and socket shall be mounted in a thermoplastic I powder coated metal box & wired Completely. TP & N 30Amps ---- etc., complete with all lead | Each | 2206.6 | 2206.6 | 92.0 | False | None | None | False | None | False | 203007.2 | 0 | 3091646 | 106301 | None | code28 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 19/20mm dia 2mm thick ---- etc., complete with all lead | Mtr | 85.67 | 85.67 | 23800.0 | False | None | None | False | None | False | 2038946.0 | 0 | 3091647 | 106301 | None | code29 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick ---- etc., complete with all lead | Mtr | 101.24 | 101.24 | 53345.0 | False | None | None | False | None | False | 5400647.8 | 0 | 3091648 | 106301 | None | code30 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 32mm dia 2.5mm thick ---- etc., complete with all lead | Mtr | 133.69 | 133.69 | 2725.0 | False | None | None | False | None | False | 364305.25 | 0 | 3091649 | 106301 | None | code31 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick ---- etc., complete with all lead | Mtr | 88.26 | 88.26 | 6265.0 | False | None | None | False | None | False | 552948.9 | 0 | 3091650 | 106301 | None | code32 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thick ---- etc., complete with all lead | Mtr | 102.54 | 102.54 | 11764.0 | False | None | None | False | None | False | 1206280.56 | 0 | 3091651 | 106301 | None | code33 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick ---- etc., complete with all lead | Mtr | 128.5 | 128.5 | 988.0 | False | None | None | False | None | False | 126958.0 | 0 | 3091652 | 106301 | None | code34 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 1.5 sqmm ---- etc., complete with all lead | Mtr | 33.75 | 33.75 | 19040.0 | False | None | None | False | None | False | 642600.0 | 0 | 3091653 | 106301 | None | code35 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 2.5 sqmm ---- etc., complete with all lead | Mtr | 54.52 | 54.52 | 50925.0 | False | None | None | False | None | False | 2776431.0 | 0 | 3091654 | 106301 | None | code36 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 4 sqmm ---- etc., complete with all lead | Mtr | 81.77 | 81.77 | 53500.0 | False | None | None | False | None | False | 4374695.0 | 0 | 3091655 | 106301 | None | code37 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 6 sqmm ---- etc., complete with all lead | Mtr | 119.42 | 119.42 | 6025.0 | False | None | None | False | None | False | 719505.5 | 0 | 3091656 | 106301 | None | code38 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 10 sqmm ---- etc., complete with all lead | Mtr | 216.77 | 216.77 | 6150.0 | False | None | None | False | None | False | 1333135.5 | 0 | 3091657 | 106301 | None | code39 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCBs single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 4 Way TP & N ---- etc., complete with all lead | Each | 5241.32 | 5241.32 | 39.0 | False | None | None | False | None | False | 204411.48 | 0 | 3091658 | 106301 | None | code40 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCBs single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & N ---- etc., complete with all lead | Each | 6412.12 | 6412.12 | 51.0 | False | None | None | False | None | False | 327018.12 | 0 | 3091659 | 106301 | None | code41 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCBs single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 12 Way SP & N ---- etc., complete with all lead | Each | 3023.04 | 3023.04 | 14.0 | False | None | None | False | None | False | 42322.56 | 0 | 3091660 | 106301 | None | code42 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP ---- etc., complete with all lead | Each | 538.67 | 538.67 | 2079.0 | False | None | None | False | None | False | 1119894.93 | 0 | 3091661 | 106301 | None | code43 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40Amps TPN ---- etc., complete with all lead | Each | 3951.11 | 3951.11 | 64.0 | False | None | None | False | None | False | 252871.04 | 0 | 3091662 | 106301 | None | code44 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., complete with all lead | Each | 4008.22 | 4008.22 | 290.0 | False | None | None | False | None | False | 1162383.8 | 0 | 3091663 | 106301 | None | code45 | Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 32-40 Amps 4 pole ---- etc., complete with all lead | Each | 6680.81 | 6680.81 | 193.0 | False | None | None | False | None | False | 1289396.33 | 0 | 3091664 | 106301 | None | code46 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 16-25 Amps 2 pole ---- etc., complete with all lead | Each | 5551.55 | 5551.55 | 36.0 | False | None | None | False | None | False | 199855.8 | 0 | 3091665 | 106301 | None | code47 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 16 sqmm ---- etc., complete with all lead | Km | 114766.56 | 114766.56 | 2.4 | False | None | None | False | None | False | 275439.744 | 0 | 3091666 | 106301 | None | code48 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 25 sqmm ---- etc., complete with all lead | Km | 181134.6 | 181134.6 | 1.9 | False | None | None | False | None | False | 344155.74 | 0 | 3091667 | 106301 | None | code49 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 35 sqmm ---- etc., complete with all lead | Km | 199972.48 | 199972.48 | 1.48 | False | None | None | False | None | False | 295959.2704 | 0 | 3091668 | 106301 | None | code50 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 50 sqmm ---- etc., complete with all lead | Km | 232306.95 | 232306.95 | 1.4 | False | None | None | False | None | False | 325229.73 | 0 | 3091669 | 106301 | None | code51 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 70 sqmm ---- etc., complete with all lead | Km | 412649.78 | 412649.78 | 0.62 | False | None | None | False | None | False | 255842.8636 | 0 | 3091670 | 106301 | None | code52 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 95 sqmm ---- etc., complete with all lead | Km | 484433.07 | 484433.07 | 1.55 | False | None | None | False | None | False | 750871.2585 | 0 | 3091671 | 106301 | None | code53 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 120 sqmm ---- etc., complete with all lead | Km | 593041.92 | 593041.92 | 1.5 | False | None | None | False | None | False | 889562.88 | 0 | 3091672 | 106301 | None | code54 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 185 sqmm ---- etc., complete with all lead | Km | 897200.96 | 897200.96 | 1.15 | False | None | None | False | None | False | 1031781.104 | 0 | 3091673 | 106301 | None | code55 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 240 sqmm ---- etc., complete with all lead | Km | 1119740.47 | 1119740.47 | 1.89 | False | None | None | False | None | False | 2116309.4883 | 0 | 3091674 | 106301 | None | code56 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 300 sqmm ---- etc., complete with all lead | Km | 1383686.17 | 1383686.17 | 0.75 | False | None | None | False | None | False | 1037764.6275 | 0 | 3091675 | 106301 | None | code57 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 400 sqmm ---- etc., complete with all lead | Km | 1886602.76 | 1886602.76 | 0.6 | False | None | None | False | None | False | 1131961.656 | 0 | 3091676 | 106301 | None | code58 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete with all lead | Km | 27110.03 | 27110.03 | 4.05 | False | None | None | False | None | False | 109795.6215 | 0 | 3091677 | 106301 | None | code59 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 sqmm to 95 sqmm ---- etc., complete with all lead | Km | 40418.42 | 40418.42 | 5.0 | False | None | None | False | None | False | 202092.1 | 0 | 3091678 | 106301 | None | code60 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 120 sqmm to 300 sqmm ---- etc., complete with all lead | Km | 41896.84 | 41896.84 | 4.99 | False | None | None | False | None | False | 209065.2316 | 0 | 3091679 | 106301 | None | code61 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 300 to 400 Sqmm ---- etc., complete with all lead | Km | 44360.45 | 44360.45 | 0.5 | False | None | None | False | None | False | 22180.225 | 0 | 3091680 | 106301 | None | code62 | Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia ---- etc., complete with all lead | Each | 151.87 | 151.87 | 61.0 | False | None | None | False | None | False | 9264.07 | 0 | 3091681 | 106301 | None | code63 | Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 63mm dia ---- etc., complete with all lead | Each | 503.62 | 503.62 | 55.0 | False | None | None | False | None | False | 27699.1 | 0 | 3091682 | 106301 | None | code64 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sqmm ---- etc., complete with all lead | Each | 16.15 | 16.15 | 99.0 | False | None | None | False | None | False | 1598.85 | 0 | 3091683 | 106301 | None | code65 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 35 sqmm Long Barrel ---- etc., complete with all lead | Each | 41.54 | 41.54 | 85.0 | False | None | None | False | None | False | 3530.9 | 0 | 3091684 | 106301 | None | code66 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 50 sqmm Long Barrel ---- etc., complete with all lead | Each | 77.88 | 77.88 | 60.0 | False | None | None | False | None | False | 4672.8 | 0 | 3091685 | 106301 | None | code67 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 70 sqmm Long Barrel ---- etc., complete with all lead | Each | 155.76 | 155.76 | 50.0 | False | None | None | False | None | False | 7788.0 | 0 | 3091686 | 106301 | None | code68 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 95 sqmm Long Barrel ---- etc., complete with all lead | Each | 194.7 | 194.7 | 70.0 | False | None | None | False | None | False | 13629.0 | 0 | 3091687 | 106301 | None | code69 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 120 sqmm Long Barrel ---- etc., complete with all lead | Each | 246.62 | 246.62 | 50.0 | False | None | None | False | None | False | 12331.0 | 0 | 3091688 | 106301 | None | code70 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 185 sqmm Long Barrel ---- etc., complete with all lead | Each | 424.45 | 424.45 | 40.0 | False | None | None | False | None | False | 16978.0 | 0 | 3091689 | 106301 | None | code71 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 240 sqmm Long Barrel ---- etc., complete with all lead | Each | 600.97 | 600.97 | 38.0 | False | None | None | False | None | False | 22836.86 | 0 | 3091690 | 106301 | None | code72 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 300 sqmm Long Barrel ---- etc., complete with all lead | Each | 813.85 | 813.85 | 90.0 | False | None | None | False | None | False | 73246.5 | 0 | 3091691 | 106301 | None | code73 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 400 sqmm Long Barrel ---- etc., complete with all lead | Each | 1229.21 | 1229.21 | 40.0 | False | None | None | False | None | False | 49168.4 | 0 | 3091692 | 106301 | None | code74 | Sandwitch raising mains with aluminum bus bar, 800A, Iscm 50 KA for 1 sec ---- etc., complete with all lead | Mtr | 20560.32 | 20560.32 | 101.0 | False | None | None | False | None | False | 2076592.32 | 0 | 3091693 | 106301 | None | code75 | 800A, TPN based end feed unit for compact rising mains including all accessories. ---- etc., complete with all lead | Each | 17211.48 | 17211.48 | 3.0 | False | None | None | False | None | False | 51634.44 | 0 | 3091694 | 106301 | None | code76 | 200A, TPN, TAP OFF Box for compact rising mains including all accessories. ---- etc., complete with all lead | Each | 8307.2 | 8307.2 | 42.0 | False | None | None | False | None | False | 348902.4 | 0 | 3091695 | 106301 | None | code77 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipments on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia ---- etc., complete with all lead | No | 4555.98 | 4555.98 | 166.0 | False | None | None | False | None | False | 756292.68 | 0 | 3091696 | 106301 | None | code78 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip ---- etc., complete with all lead | Mtr | 106.44 | 106.44 | 1875.0 | False | None | None | False | None | False | 199575.0 | 0 | 3091697 | 106301 | None | code79 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm Copper strip ---- etc., complete with all lead | Mtr | 739.86 | 739.86 | 650.0 | False | None | None | False | None | False | 480909.0 | 0 | 3091698 | 106301 | None | code80 | Supply of round/square recess/surface mounted rolling type LED Down light with W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12W ---- etc., complete with all lead | Each | 1148.73 | 1148.73 | 660.0 | False | None | None | False | None | False | 758161.8 | 0 | 3091699 | 106301 | None | code81 | Supply of round/square recess/surface mounted rolling type LED Down light with W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W ---- etc., complete with all lead | Each | 1718.55 | 1718.55 | 1206.0 | False | None | None | False | None | False | 2072571.3 | 0 | 3091700 | 106301 | None | code82 | Supplying of feet - PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4- 20/22 w ---- etc., complete with all lead | Each | 895.62 | 895.62 | 784.0 | False | None | None | False | None | False | 702166.08 | 0 | 3091701 | 106301 | None | code83 | Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete with all lead | Each | 193.4 | 193.4 | 142.0 | False | None | None | False | None | False | 27462.8 | 0 | 3091702 | 106301 | None | code84 | Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K ---- etc., complete with all lead | Each | 349.16 | 349.16 | 79.0 | False | None | None | False | None | False | 27583.64 | 0 | 3091703 | 106301 | None | code85 | Supplying of recess mounting non integral type ........LED ...... W luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded fase ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, , THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2x2 - 34 -36watt ---- etc., complete with all lead | Each | 5909.79 | 5909.79 | 892.0 | False | None | None | False | None | False | 5271532.68 | 0 | 3091704 | 106301 | None | code86 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40watts ---- etc., complete with all lead | No | 5223.15 | 5223.15 | 40.0 | False | None | None | False | None | False | 208926.0 | 0 | 3091705 | 106301 | None | code87 | Supplying exhaust fan of 1440 RPM of 300mm (12) size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete with all lead | Each | 1936.62 | 1936.62 | 195.0 | False | None | None | False | None | False | 377640.9 | 0 | 3091706 | 106301 | None | code88 | Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 15 Sweep (450mm) ---- etc., complete with all lead | Each | 5355.55 | 5355.55 | 30.0 | False | None | None | False | None | False | 160666.5 | 0 | 3091707 | 106301 | None | code89 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48 Sweep 5 Star (1200 mm) ---- etc., complete with all lead | Each | 5585.29 | 5585.29 | 488.0 | False | None | None | False | None | False | 2725621.52 | 0 | 3091708 | 106301 | None | code90 | Supplying wall mounting fan suitable to operate at singlephase 230v A.C. supply. 300mm Sweep ---- etc., complete with all lead | Each | 3234.62 | 3234.62 | 67.0 | False | None | None | False | None | False | 216719.54 | 0 | 3091709 | 106301 | None | code91 | Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- etc., complete with all lead | Each | 81.77 | 81.77 | 174.0 | False | None | None | False | None | False | 14227.98 | 0 | 3091710 | 106301 | None | code92 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete with all lead | Each | 158.36 | 158.36 | 3721.0 | False | None | None | False | None | False | 589257.56 | 0 | 3091711 | 106301 | None | code93 | Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and S hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size
wooden board and wired. ---- etc., complete with all lead | Each | 408.87 | 408.87 | 683.0 | False | None | None | False | None | False | 279258.21 | 0 | 3091712 | 106301 | None | code94 | Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete with all lead | Each | 917.69 | 917.69 | 225.0 | False | None | None | False | None | False | 206480.25 | 0 | 3091713 | 106301 | None | code95 | Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr Length ---- etc., complete with all lead | Each | 1896.38 | 1896.38 | 96.0 | False | None | None | False | None | False | 182052.48 | 0 | 3091714 | 106301 | None | code96 | Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete with all lead | Each | 210.28 | 210.28 | 91.0 | False | None | None | False | None | False | 19135.48 | 0 | 3091715 | 106301 | None | code97 | Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 14SWG ---- etc., complete with all lead | Sq CM | 0.64 | 0.64 | 5140000.0 | False | None | None | False | None | False | 3289600.0 | 0 | 3091716 | 106301 | None | code98 | Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 1000 A double run of 4 x 60 x 10 mm Aluminium Strips ---- etc., complete with all lead | Mtr | 13732.84 | 13732.84 | 136.0 | False | None | None | False | None | False | 1867666.24 | 0 | 3091717 | 106301 | None | code99 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75x75x6mm ---- etc., complete with all lead | Mtr | 720.39 | 720.39 | 209.0 | False | None | None | False | None | False | 150561.51 | 0 | 3091718 | 106301 | None | code100 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75x150x75x6mm C channel ---- etc., complete with all lead | Mtr | 1201.95 | 1201.95 | 209.0 | False | None | None | False | None | False | 251207.55 | 0 | 3091719 | 106301 | None | code101 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE100Amps 25kA ---- etc., complete with all lead | Each | 11016.13 | 11016.13 | 149.0 | False | None | None | False | None | False | 1641403.37 | 0 | 3091720 | 106301 | None | code102 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE100Amps 25kA125Amps 25kA ---- etc., complete with all lead | Each | 13422.62 | 13422.62 | 29.0 | False | None | None | False | None | False | 389255.98 | 0 | 3091721 | 106301 | None | code103 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE100Amps 25kA 160Amps 25kA ---- etc., complete with all lead | Each | 17454.21 | 17454.21 | 37.0 | False | None | None | False | None | False | 645805.77 | 0 | 3091722 | 106301 | None | code104 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE100Amps 25kA 250Amps 35kA ---- etc., complete with all lead | Each | 27765.52 | 27765.52 | 10.0 | False | None | None | False | None | False | 277655.2 | 0 | 3091723 | 106301 | None | code105 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Therm IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE320-400Amps 50kA ---- etc., complete with all lead | Each | 39084.08 | 39084.08 | 9.0 | False | None | None | False | None | False | 351756.72 | 0 | 3091724 | 106301 | None | code106 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Therm IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 700-800 A 50 kA ---- etc., complete with all lead | Each | 64770.2 | 64770.2 | 5.0 | False | None | None | False | None | False | 323851.0 | 0 | 3091725 | 106301 | None | code107 | Supply and fixing of fully Enclosed 250A Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,.Adjustable Time Delay(0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 Volts ---- etc., complete with all lead | Each | 136082.32 | 136082.32 | 3.0 | False | None | None | False | None | False | 408246.96 | 0 | 3091726 | 106301 | None | code108 | Supplying and fixing of 800A, FP, 50kA, microprocessor based Motorised ACB electrical drawout type.over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) ---- etc., complete with all lead | Each | 177000.0 | 177000.0 | 9.0 | False | None | None | False | None | False | 1593000.0 | 0 | 3091727 | 106301 | None | code109 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board ---- etc., complete with all lead | Each | 12012.99 | 12012.99 | 8.0 | False | None | None | False | None | False | 96103.92 | 0 | 3091728 | 106301 | None | code110 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete with all lead | Each | 12090.87 | 12090.87 | 62.0 | False | None | None | False | None | False | 749633.94 | 0 | 3091729 | 106301 | None | code111 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete with all lead | Each | 668.47 | 668.47 | 171.0 | False | None | None | False | None | False | 114308.37 | 0 | 3091730 | 106301 | None | code112 | Supplying, fixing and wiring 50/5 to 400/5Amps 15VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., complete with all lead | Each | 729.48 | 729.48 | 164.0 | False | None | None | False | None | False | 119634.72 | 0 | 3091731 | 106301 | None | code113 | Suppiying and fixing of Shunt trip suitable for MCCB.CBCT ---- etc., complete with all lead | Each | 2210.49 | 2210.49 | 6.0 | False | None | None | False | None | False | 13262.94 | 0 | 3091732 | 106301 | None | code114 | Supplying,fixing and wiring 1000/5A to 1600/5A 15VA Burden class 1 Current Transformer ---- etc., complete with all lead | Each | 1090.32 | 1090.32 | 6.0 | False | None | None | False | None | False | 6541.92 | 0 | 3091733 | 106301 | None | code115 | Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete with all lead | Sq CM | 0.56 | 0.56 | 13563000.0 | False | None | None | False | None | False | 7595280.0 | 0 | 3091734 | 106301 | None | code116 | Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 400Amps 4x50x10mm Aluminum Strips ---- etc., complete with all lead | Mtr | 5769.61 | 5769.61 | 50.0 | False | None | None | False | None | False | 288480.5 | 0 | 3091735 | 106301 | None | code117 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x50x6mm ---- etc., complete with all lead | Mtr | 512.71 | 512.71 | 60.0 | False | None | None | False | None | False | 30762.6 | 0 | 3091736 | 106301 | None | code118 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete with all lead | Mtr | 981.29 | 981.29 | 610.0 | False | None | None | False | None | False | 598586.9 | 0 | 3091737 | 106301 | None | code119 | Supplying, fixing and wiring Automatic Power Factor controller fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three place LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect I disconnect banks, with automatic recognition or with standard programs. ---- etc., complete with all lead | Each | 28088.72 | 28088.72 | 5.0 | False | None | None | False | None | False | 140443.6 | 0 | 3091738 | 106301 | None | code120 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery ---- etc., complete with all lead | Kvar | 623.04 | 623.04 | 600.0 | False | None | None | False | None | False | 373824.0 | 0 | 3091739 | 106301 | None | code121 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 Amps ---- etc., complete with all lead | Each | 1674.42 | 1674.42 | 25.0 | False | None | None | False | None | False | 41860.5 | 0 | 3091740 | 106301 | None | code122 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 40 Amps ---- etc., complete with all lead | Each | 2930.88 | 2930.88 | 30.0 | False | None | None | False | None | False | 87926.4 | 0 | 3091741 | 106301 | None | code123 | Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Strips ---- etc., complete with all lead | Mtr | 3199.57 | 3199.57 | 97.0 | False | None | None | False | None | False | 310358.29 | 0 | 3091742 | 106301 | None | code124 | Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete with all lead | Mtr | 4458.63 | 4458.63 | 151.0 | False | None | None | False | None | False | 673253.13 | 0 | 3091743 | 106301 | None | code125 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete with all lead | Mtr | 395.89 | 395.89 | 550.0 | False | None | None | False | None | False | 217739.5 | 0 | 3091744 | 106301 | None | code126 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps DP ---- etc., complete with all lead | Each | 959.22 | 959.22 | 93.0 | False | None | None | False | None | False | 89207.46 | 0 | 3091745 | 106301 | None | code127 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps TPN ---- etc., complete with all lead | Each | 2228.67 | 2228.67 | 104.0 | False | None | None | False | None | False | 231781.68 | 0 | 3091746 | 106301 | None | code128 | Supplying fully automatic star-delta starter unit push button type with suitable wires, 3 contactors, one adjustable thermal timer mounted on a common base plate held in steel enclosure for use on 400/440 volts 3 phase and wired ajter fixing to the existing wooden board for motor Upto 12.5 HP ---- etc., complete with all lead | Each | 9676.59 | 9676.59 | 48.0 | False | None | None | False | None | False | 464476.32 | 0 | 3091747 | 106301 | None | code129 | STREET LIGHTING PANEL-Fabricating, Supplying & Mounting M.S. Box made out of 16 SWG of size 700x750x220mm suitable for floor / wall mounting, fully weather proof with provision for better heat desipation, with two chambers & window for energy meter, provided with hinged front cover, two inside doors, with tamper proof locking arrangments, suitable size clamps with necessary cable entry pipe with gland and box should be finished with two coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete. The box should be mounted on M.S.angle iron of size 40x40x6mm (total length 4.7 mtr) with 1:2:4 concreting (0.25x0.75x0.9 mtr) including coping. provision for housing 3 phase energy meter, suitable size bus bar, 100 A cut out (3 Nos), with timer (3-120sec) & contactorc) (60-70Amps), 63 A MCB TPN (1 No), 2 Nos 32 A TPN MCB on 4mm thick hylum sheet, wiring with suitable size copper wire & lugs. The box should be earthed with pipe type earthing. (AS PER PWD SR) ---- etc., complete with all lead | Set | 59000.0 | 59000.0 | 2.0 | False | None | None | False | None | False | 118000.0 | 0 | 3091748 | 106301 | None | code130 | Fabricating, supplying and erecting swaged tubular pole of height …Mtr having three sections, and providing two coats of red oxide paint and finished with two coats of enamelled paint of approved quality and colour and M.S. base plate of suitable size welded at the bottom of the pole(as per IS) and 40mm dia GI / flexible PVC pipe of 1 mtr length fitted to the heavy gauge polycarbonate control box including 5way connector of size 167x125x82mm for 7.5M pole/200x160x98mm for remaining length of pole with front opening cover, with locking arrangements and suitable capacity MCB / DP switch, The pole shall be erected in cement concrete work (1:2:4) including excavation and refilling of planting depth of the pole to the ground level and the coping CC shall be up to 0.6M above ground level as per IS 2713 - 7. Erection of heavy duty pole on Footpath / median 9Mt (5Mt Hb,165.1mm dia 4.85mm thick x2M Hm, 139.7mm dia 4.50mm thick x 2M Ht,114.3mm dia 3.65mm thick) as per IS 410 SP 32 ---- etc., complete with all lead | Each | 20119.0 | 20119.0 | 55.0 | False | None | None | False | None | False | 1106545.0 | 0 | 3091749 | 106301 | None | code131 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 70watts ---- etc., complete with all lead | No | 7777.62 | 7777.62 | 70.0 | False | None | None | False | None | False | 544433.4 | 0 | 3091750 | 106301 | None | code132 | Supply of LED Bollard light fitting of ...W with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB, with 2 years Warranty against any manufacturing defect working under standard electrical condition. 8W 1 Mtr Height ---- etc., complete with all lead | Each | 5878.58 | 5878.58 | 50.0 | False | None | None | False | None | False | 293929.0 | 0 | 3091751 | 106301 | None | code133 | Providing and fixing of lightning conductor finial, made of 25mm dia 300 mm long GI tube, having single prong a top, with 85mm dia 6 mm thick base plate including holes etc., compelete as required ---- etc., complete with all lead | Each | 672.36 | 672.36 | 70.0 | False | None | None | False | None | False | 47065.2 | 0 | 3091752 | 106301 | None | code134 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI strip ---- etc., complete with all lead | Mtr | 166.14 | 166.14 | 2410.0 | False | None | None | False | None | False | 400397.4 | 0 | 3091753 | 106301 | None | code135 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 40x6mm Copper strip ---- etc., complete with all lead | Mtr | 2132.61 | 2132.61 | 345.0 | False | None | None | False | None | False | 735750.45 | 0 | 3091754 | 106301 | None | code136 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm Copper plate ---- etc., complete with all lead | Each | 9632.46 | 9632.46 | 136.0 | False | None | None | False | None | False | 1310014.56 | 0 | 3091755 | 106301 | None | code137 | Supply of 08 KVA Isolated Power Distribution panel for OT with Online monitoring, with fault location and with Programmable Remote Alarm Indicator :
Electrical Safety system: IEC 60364-7-710: “Electrical installation ofbuildings-Requirements for special installations for medical locations”( Group-2) and Indian NEC- SP-30- Section 4, 2011, provision P5 requires unearthed(IT) system for all critical medical locations ( O.T, I.C.U, I.C.C.U, PrematureBaby Room etc). Therefore, an Electrical Safety Alarm System shall beinstalled to ensure patient and employee safety against risk of electrical shock, fire and damage of electrical insulation used in equipment and powerdistribution circuits. The system shall provide perfect ungrounded powersupply system in OT; ensure no fire, no electrical spark, no MCB tripping evenin case of 1st insulation fault (BIS NEC-SP-30 , P5 location requirement);ensure 24X7 Insulation monitoring of entire electrical distribution system &an audio visual remote and local alarm even in case of 1st fault; never give anyspurious alarm / false alarm, fool proof against EMI/EMC effects; should havea system to identify faulty feeder / socket / equipment online without trippingthe system; a periodic self diagnostic features to identify malfunctions in thesystem itself. Insulation monitoring devices using a Active measuring principle in compliance with IEC 61557-8&IEC-60364-7-710 should be used.Insulation monitor shall have facility to monitor over current and temperature monitoring facility of the Isolation transformer.Fault Location system should be in accordance with IEC 61557-9 & IEC 60364-7-710. a.An Isolation Transformer 10KVA max as per IEC-61558-2 & IEC-60364-7-710 along with insulation monitoring device& fault location system shall be provided as mentioned above. Supplier/ Vender to quote necessary hardware to fulfill the requirement. b.A complete panel consisting of all items along with indicating lamp for (Mains On, Healthy & Faulty condition), MCBs, Exhaust Fan and air filter shall be supplied. All internal wiring should terminate in connectors with screw and clampspring connections of the Klippon type mounted, on a DIN rail and labeledwith indelible proprietary labels. Individual fuses or miniature circuitbreakers should protect all internal circuits. All internal wiring should be ofthe high temperature type and enclosed in propriety ducting or mini. Allinternal wires should be marked with plastic ferrule type cable markers, forease of identification.Bender Make or Equivalent. ---- etc., complete with all lead | Each | 1318060.0 | 1318060.0 | 5.0 | False | None | None | False | None | False | 6590300.0 | 0 | 3091756 | 106301 | None | code138 | Design, supplying, erecting testing and commissioning of - 15 Passenger/ Bed-cum-passenger hospital lift(8 stops/8 Opening) with speed of 1.5 mtr per second, variable voltage variable frequency drive, with or without machine room for the available well size, operating at 415 V 3 phase 50 cycles AC supply, powder coated / Stainless Steel car entrance doors enclosures with suitable colour vinyl flooring, LED car illumination, emergency light, intercom and fan as desired by the user, central opening / side opening door with or without attendant operation, 7 segment display buttons, call register indicator, fireman drive, SS handrails inside car, full length infrared curtain in car door, automatic rescue device with batteries, voice announcing in regional/ international languages, Braille buttons with one year warranty and maintenance with necessary scaffolding and minor civil works like fixing of guide rail, counter weight etc.,The total product and services shall adhere to IS 14665/2016 ( with latest amendments) part/section 1 to 5 with regards to general guidelines of fire safety rated doors, MRLL beams, pressure switch, manual change over for doors during emergency, ARD of 10 times with sufficient battery back up and standard dimensions of chair car and door openings for all sizes and capacities of lifts including fitness certificate and duly observing all other safety norms prescribed and adhere to CPWD specifications, PCB Norms, National Electricity Code (NEC), NBC-2016, IEC and Karnataka State Lifts, Escalators and Passengers Conveyers Act 2012 and Rules 2014. The Supplier shall be registered in Government Electrical Inspectorate in the State of Karnataka. ---- etc., complete with all lead | Each | 3308478.01 | 3308478.01 | 2.0 | False | None | None | False | None | False | 6616956.02 | 0 | 3091757 | 106301 | None | code139 | Supply, Installation Testing and commissioning of 30 KVA Double Conversion online with Inbuilt Isolation Transformer. Three Phase Input, Three Phase Output (With bi-directional Static and manual by-pass Switch).
* With IGBT for Rectifier and Inverter
* With Input current harmonics 3% (THDi)
* With Input Power Factor 0.99
* With overall efficiency 0.93%
Interconnecting cables between batteries, DC
Cables between UPS & Batteries (5 Mtrs.Max)
With Suitable Battery Stand, 30 min backup. ---- etc., complete with all lead | Each | 377600.0 | 377600.0 | 2.0 | False | None | None | False | None | False | 755200.0 | 0 | 3091758 | 106301 | None | code140 | Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 75/80 AH capacity ---- etc., complete with all lead | Each | 13203.26 | 13203.26 | 144.0 | False | None | None | False | None | False | 1901269.44 | 0 | 3091759 | 106301 | None | code141 | RJ45/ I.O. outlet Cat 6 ---- etc., complete with all lead | Each | 437.43 | 437.43 | 381.0 | False | None | None | False | None | False | 166660.83 | 0 | 3091760 | 106301 | None | code142 | Telephone socket ---- etc., complete with all lead | Each | 202.49 | 202.49 | 168.0 | False | None | None | False | None | False | 34018.32 | 0 | 3091761 | 106301 | None | code143 | Supplying and drawing UTP-CAT 6E LAN cable. ---- etc., complete with all lead | Mtr | 49.32 | 49.32 | 30450.0 | False | None | None | False | None | False | 1501794.0 | 0 | 3091762 | 106301 | None | code144 | Supplying & Fixing of I/O Socket with back box Single I/O ---- etc., complete with all lead | Each | 636.02 | 636.02 | 300.0 | False | None | None | False | None | False | 190806.0 | 0 | 3091763 | 106301 | None | code145 | Supplying & Fixing of switch mounting rack with power manager & Cable manager as per standard specification 9U with 450mm depth ---- etc., complete with all lead | Each | 11001.85 | 11001.85 | 23.0 | False | None | None | False | None | False | 253042.55 | 0 | 3091764 | 106301 | None | code146 | Supplying fixing of Network Switches. 16 port 10/100/1000 Switch ---- etc., complete with all lead | Each | 8359.12 | 8359.12 | 18.0 | False | None | None | False | None | False | 150464.16 | 0 | 3091765 | 106301 | None | code147 | Supplying & fixing of ..mtrs. Cat 6Patch Cable. 2Mtr ---- etc., complete with all lead | Each | 333.59 | 333.59 | 381.0 | False | None | None | False | None | False | 127097.79 | 0 | 3091766 | 106301 | None | code148 | Supplying & Fixing of Patch panel for Lan Cabling. 16 Port 10/100 patch panel ---- etc., complete with all lead | Each | 3958.9 | 3958.9 | 20.0 | False | None | None | False | None | False | 79178.0 | 0 | 3091767 | 106301 | None | code149 | Supplying and drawing PVC flexible 2 pair telepone unarmoured tinned copper cable. ---- etc., complete with all lead | Mtr | 27.26 | 27.26 | 7760.0 | False | None | None | False | None | False | 211537.6 | 0 | 3091768 | 106301 | None | code150 | Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination. 20 Pair ---- etc., complete with all lead | Each | 497.13 | 497.13 | 7.0 | False | None | None | False | None | False | 3479.91 | 0 | 3091769 | 106301 | None | code151 | EPABX:- Supply,Installation,Testing & Commissioning of micro-processor based, state of the Art, Telephone PBX System , IP READY,based on Linux/GRUB compliant, integrated Software for multiTasking for Hospitality Services including Billing ,comprising of items as below but not limited to them. Expanadable upto 50 Ports Providing PRI cards for Trunk lines / for tie line with reqd.software 16Analog Trunk Lines 4 Digital Extensions 20 Analogue Extensions( Expandable up to 50) In-Built Voicemail ( 4 Port & 80 Min) LAN Connectivity Embedded WELCOME MESSAGE Least Cost Routing Personal Assistant Music on Hold . ---- etc., complete with all lead | Nos | 141600.0 | 141600.0 | 2.0 | False | None | None | False | None | False | 283200.0 | 0 | 3091770 | 106301 | None | code152 | TELEPHONES Analog push button telephone with Caller ID, flash and radial ---- etc., complete with all lead | Nos | 2124.0 | 2124.0 | 115.0 | False | None | None | False | None | False | 244260.0 | 0 | 3091771 | 106301 | None | code153 | Supply, Installation, Testing and Commissioning of 6-core OFC - Armoured outdoor cable (SM) ---- etc., complete with all lead | Mtr | 115.64 | 115.64 | 600.0 | False | None | None | False | None | False | 69384.0 | 0 | 3091772 | 106301 | None | code154 | IP DOME CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8x2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),30M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets. ---- etc., complete with all lead | Each | 23836.0 | 23836.0 | 83.0 | False | None | None | False | None | False | 1978388.0 | 0 | 3091773 | 106301 | None | code155 | IP BULLET CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8x2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),60M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets. ---- etc., complete with all lead | Each | 25606.0 | 25606.0 | 23.0 | False | None | None | False | None | False | 588938.0 | 0 | 3091774 | 106301 | None | code156 | IP PTZ CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8x2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),60M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets. ---- etc., complete with all lead | Each | 177000.0 | 177000.0 | 4.0 | False | None | None | False | None | False | 708000.0 | 0 | 3091775 | 106301 | None | code157 | Supplying, installation, testing and commissioning of SITC of complete 32 channel 4K embedded network video recorder,up to 12MP(4K) resolution live view,preview,and play back,full POE Support (for up to 16 channels),internal storage supports 8HDDs expandable up to 64TB (8TB each),operating temperatures(-10 degree C) and (55 degree C),UL,CE,FCC. ---- etc., complete with all lead | Each | 271400.0 | 271400.0 | 3.0 | False | None | None | False | None | False | 814200.0 | 0 | 3091776 | 106301 | None | code158 | Supply and Installation of 4 TB Survalance Hard Disk The rate shall include all mounting accessories complete as required ---- etc., complete with all lead | Each | 17110.0 | 17110.0 | 32.0 | False | None | None | False | None | False | 547520.0 | 0 | 3091777 | 106301 | None | code159 | Supply and Installation of 16 Port L2 Managed Poe Switch The rate shall include all mounting accessories complete as required ---- etc., complete with all lead | Each | 47495.0 | 47495.0 | 8.0 | False | None | None | False | None | False | 379960.0 | 0 | 3091778 | 106301 | None | code160 | Supply and Installation of I/Os ---- etc., complete with all lead | Each | 147.5 | 147.5 | 280.0 | False | None | None | False | None | False | 41300.0 | 0 | 3091779 | 106301 | None | code161 | Supply and Installation of 2 Mtrs Patch Chord The rate shall include all mounting accessories complete as required ---- etc., complete with all lead | Each | 265.5 | 265.5 | 80.0 | False | None | None | False | None | False | 21240.0 | 0 | 3091780 | 106301 | None | code162 | Supply and Installation of Quad Face Plate Camera Side With IOS The rate shall include all mounting accessories complete as required ---- etc., complete with all lead | Each | 336.3 | 336.3 | 80.0 | False | None | None | False | None | False | 26904.0 | 0 | 3091781 | 106301 | None | code163 | Supply and Installation of 6 Core Single Mode Ofc Cable The rate shall include all mounting accessories complete as required ---- etc., complete with all lead | Mtr | 115.64 | 115.64 | 400.0 | False | None | None | False | None | False | 46256.0 | 0 | 3091782 | 106301 | None | code164 | Supply and Installation of 43LED Monitor The rate shall include all mounting accessories complete as required ---- etc., complete with all lead | Each | 70800.0 | 70800.0 | 4.0 | False | None | None | False | None | False | 283200.0 | 0 | 3091783 | 106301 | None | code165 | Supplying & Fixing of Patch panel for LAN cabling .24 Port 10/100 patch panel ---- etc., complete with all lead | Each | 5321.8 | 5321.8 | 7.0 | False | None | None | False | None | False | 37252.6 | 0 | 3091784 | 106301 | None | code166 | TV socket ---- etc., complete with all lead | Each | 202.49 | 202.49 | 18.0 | False | None | None | False | None | False | 3644.82 | 0 | 3091785 | 106301 | None | code167 | The Scope of work is Supply,istallation, Testing for T.V. System with following Items & components in Rooms & other Specific Areas. It also covers co-ordination with T.V service provider for completeness & usage of the Items /components erected by Vendor.Booster amplifier. ---- etc., complete with all lead | Each | 3540.0 | 3540.0 | 7.0 | False | None | None | False | None | False | 24780.0 | 0 | 3091786 | 106301 | None | code168 | The Scope of work is Supply,istallation, Testing for T.V. System with following Items & components in Rooms & other Specific Areas. It also covers co-ordination with T.V service provider for completeness & usage of the Items /components erected by Vendor. 3 way splitter. ---- etc., complete with all lead | Each | 236.0 | 236.0 | 14.0 | False | None | None | False | None | False | 3304.0 | 0 | 3091787 | 106301 | None | code169 | Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6. ---- etc., complete with all lead | Rmtr | 57.11 | 57.11 | 1200.0 | False | None | None | False | None | False | 68532.0 | 0 | 3091788 | 106301 | None | code170 | Supply and installation of Bedded Panel with 4 nos 6 amps sockets and 4 nos 16 amps sockets with switches and 6 watt LED light fixtures & Provision for 4Nos gas pipeline sockets. ---- etc., complete with all lead | Each | 10030.0 | 10030.0 | 193.0 | False | None | None | False | None | False | 1935790.0 | 0 | 3091789 | 106301 | None | code171 | Design, supplying, erecting testing and commissioning of - 20Passenger/ Bed-cum-passenger hospital lift(7 stops/7 Opening) with speed of 1.5 mtr per second, variable voltage variable frequency drive, with or without machine room for the available well size, operating at 415 V 3 phase 50 cycles AC supply, powder coated / Stainless Steel car entrance doors enclosures with suitable colour vinyl flooring, LED car illumination, emergency light, intercom and fan as desired by the user, central opening / side opening door with or without attendant operation, 7 segment display buttons, call register indicator, fireman drive, SS handrails inside car, full length infrared curtain in car door, automatic rescue device with batteries, voice announcing in regional/ international languages, Braille buttons with one year warranty and maintenance with necessary scaffolding and minor civil works like fixing of guide rail, counter weight etc.,The total product and services shall adhere to IS 14665/2016 ( with latest amendments) part/section 1 to 5 with regards to general guidelines of fire safety rated doors, MRLL beams, pressure switch, manual change over for doors during emergency, ARD of 10 times with sufficient battery back up and standard dimensions of chair car and door openings for all sizes and capacities of lifts including fitness certificate and duly observing all other safety norms prescribed and adhere to CPWD specifications, PCB Norms, National Electricity Code (NEC), NBC-2016, IEC and Karnataka State Lifts, Escalators and Passengers Conveyers Act 2012 and Rules 2014. The Supplier shall be registered in Government Electrical Inspectorate in the State of Karnataka. ---- etc., complete with all lead | Each | 4838625.03 | 4838625.03 | 3.0 | False | None | None | False | None | False | 14515875.09 | 0 | 3091790 | 106301 | None | code172 | 2x40kVA, 120 KVA Hot swappable Modular UPS. Digital Technology Three Phase Input, Three Phase Output (With bi-directional Static and manual by pass Switch).
With IGBT for Rectifier and Inverter
With Input current harmonics 3% (THD)
With Input Power Factor 0.99
With overall efficiency 0.93%
With Isolation Transformer Interconnecting cables between batteries, DC Cables between UPS & Batteries 5 Mtrs.Max With Suitable Battery Stand Each bank with 30min backup ---- etc., complete with all lead | Each | 1298000.0 | 1298000.0 | 1.0 | False | None | None | False | None | False | 1298000.0 | 0 | 3091791 | 106301 | None | code173 | Supply, installation, testing and commissioning of The Bedside call unit shall be mounted on the head boards where there are patient headboards or on the walls where it can be implemented within the system.The Bedside call unit shall be 2 input\output ports for RJ45 Endings for cabling in a chain with overdoor lights and other call units and eventually to one zone controller. On the standard bedside call unit front side there shall be: An End Call Button with a green tick mark symbol.Reassurance backlight in order to give visual information about call ststus.Continous backlight for easy visibility of the unit at night.Pressing on the end call button ends the call and turns the assigned overdoor light to green. IP System controller logs the event as PresencePressing the end call button for the second time ends the presence and turns off the assigned overdoor light.The Bedside Call Unit shall made from noninflammable PC-ABS-FR Materials.It can be used individually as a call button where patient handset is not needed. Other wise, its connection with the patient handset shall be easily established ny the connecting via RJ45 on its front side.A Nurse call shall be initated via the patient handset or the bedside call unit. These two buttons shall be accepted by the system as equivalent. In the event that these buttons are pressed.If the unit is ablee to transmit the call to the zone controller, the LED on the unit shall flash with 1.0 second intervals, call transmission information shall be audibly notified to the patient.If there is an error in the call transmission, a continuous red light showing error status shall only stop when the call termination button is pressed, subsequent presses of the button shall trigger an audio alert each time.Its connection shall be made with cat 6 UTP Cable RJ45 of B Standard.This device shall be powered by the Zone Controller. ---- etc., complete with all lead | Nos | 4130.0 | 4130.0 | 193.0 | False | None | None | False | None | False | 797090.0 | 0 | 3091792 | 106301 | None | code174 | Supply, installation, testing and commissioning of PATIENT HANDSET BASIC.This Handset will be used in the locations that are connected to the system by a zone controller.It Shall be ergonomically suitable to be handheld.It shall be connected to the bedside call unit with an independent cable.on its front side there shall be A start Call Button with red nurse symbol.Reassurance LED light in order to give visual information about the call status.Continues LED Light for easy visibility at night.Call Initation and error notification procedures is the same as bedside call unit except audio alerts are always issued by the bedside call unit its call initiation button and back light works in parallel with the one on the bedside call unit.It shall have an easily cleanable surface that dose not promote bacterial growth.Patient handset shall be made from non inflammable PC-ABS-FR Materials. ---- etc., complete with all lead | Nos | 5900.0 | 5900.0 | 193.0 | False | None | None | False | None | False | 1138700.0 | 0 | 3091793 | 106301 | None | code175 | Supply, installation, testing and commissioning of CODE BLIE CALL UNIT;- The Code Blue Call Unit shall be mounted on headboards where there are patient headboards or on the walls where it can be implemented within the system. The Code Blue Call Unit has 2 Input/Output ports for RJ45 endings for cabling in a chain with Over Door Lights and other call units and eventually to one Zone Controller.
On the Code Blue call unit front side there shall be; A “start code blue” button with a blue medicine symbol. Pressing the button initiates a Code Blue event, turning on the assigned Overdoor lights to Blue. An “end code blue” button with a green tick mark symbol. Pressing the Button shall cancel the Code blue alarm turning the assigned Overdoor lights. Reassurance backlight in order to give visual information about the call status. Continuous backlight for easy visibility of the unit at night. The Code Blue Call Unit shall be made from nonflammable PC-ABS-FR materials. If the unit is able to transmit the call to the zone controller, the LED on the unit shall flash with 1.0-second intervals. Call transmission information shall be audibly notified to the patient. If there is an error in call transmission, a continuous red light showing the error status shall only stop when the call termination button is pressed or room control connection is made. Subsequent presses of the button shall trigger an audio alert each time. Its connection shall be made with Cat 6 UTP cable and RJ45 of B standard. ---- etc., complete with all lead | Nos | 4071.0 | 4071.0 | 193.0 | False | None | None | False | None | False | 785703.0 | 0 | 3091794 | 106301 | None | code176 | Supply, installation, testing and commissioning of PULL-CORD CALL UNIT(WC\Bathroom)-The Pull-cord call unit has 2 input\output ports for RJ45 Ending for cabling in a chain with overdoor lights and other call units and eventually to one zone controller. on its front side there shall be A pull-code call unit with customizable length with minimum 1.5 meters to serve as a call-code.A call termination button (indicated by a green tick Mark Symbol).Its Connection shall be made with CAT6 UTP cable and RJ45 of B standard.A priority WC Emergency call shall start when the cord is pulled.This Device will be used in the locations that are connected to the system by a zone controller. ---- etc., complete with all lead | Nos | 4189.0 | 4189.0 | 25.0 | False | None | None | False | None | False | 104725.0 | 0 | 3091795 | 106301 | None | code177 | Supply, installation, testing and commissioning of Over Door Light shall use environmentally friendly LEDs.It shall consist of Red, Green, Blue, white, Pink Colored Warning Light.In Normal Condition, no light shall be lit, if the patient makes nurse call, Red Light shall be Lit with in 0.5 Seconds. After all nurse call, when the nurse presses the green presence button on the call unit, the light of the over door light will return green.In code blue, the blue light shall be lit.The outer casing of the over door light shall be made of nonflammble PC-ABS-FR Materials.Over door light shall have 2 input\output ports for RJ45 ending for cabling in a chain with call units on one of the communication lines of the zone controller. Alternativley, it connects to the RCU in private & semi private rooms.Its connection shall be made with cat 6 UTP Cable RJ45 of B Standard.This device shall be powered by the Zone Controller or black colored communication ports of RCU unit to which it is connected. It shall not require additional energy supply. ---- etc., complete with all lead | Nos | 11463.7 | 11463.7 | 25.0 | False | None | None | False | None | False | 286592.5 | 0 | 3091796 | 106301 | None | code178 | Supply, installation, testing and commissioning of IP BASED NURSE CALL SYSTEM Supply, Installation, testing and commissioning of the IP based Nurse Call System based on the following components including but not restricted to gold plated connecting leads, connectors, patch cables, jumpers, nuts, screws, bolts, mounting plates, cover plates, back boxes etc., Shall be in accordance with International guidelines and shall be in such a way that the most effective communication between Patient, Nursing Staff, Doctor & management staff can be provided in the least possible time. System Operation\Ward Nurse Station;-The ward Nurse Station Shall be used in the location that are connected to the system by a zone controller. It is placed in each multi bed ward areas at the nurse station overlooking the patent beds.The ward Nurse station Shall have a minimum 10 Inch touchscreen and include its own integrated handsfree voice communication with other Nurse control Panels.The Nurse control panel may be used to monitor the status of every assigned call points, call and alarm status.the screen will show active calls and emergency code with top to bottom priority, highest priority active calls is on top and longest awaiting calls within same call type having more priority than same type.The origin room and the bed information of all active nurse calls, code blue calls shall be shown with an audiovisual alert along with the call type.onscreen call points shall have notification of relevant icons, colors, and tones according to their call status as well as time the call started and time passed since.call shall be shown real time. Each activity will be send to IP System Controller for logging enabling later inspection and reporting.Time stamp and error logs for situations when the energy supply of the panel is cut or there is no network connection shall be recorded on the IP System controller.Emergency codeblue, Red, pink, and white shall be initiated from the touch screen. ---- etc., complete with all lead | Nos | 95138.68 | 95138.68 | 12.0 | False | None | None | False | None | False | 1141664.16 | 0 | 3091797 | 106301 | None | code179 | Supply, installation, testing and commissioning of IP ZONE CONTROLLER This is the main node device used to network the Nurse call system devices to each other for areas are not private or semi-private rooms and do not have item 3.2(RCU). It is to be used for multi bed wards areas in a single open soace with a nurse desk overlooking the assigned patient beds.Each zone controller has 2 communication ports which support chains of up to 24 calls initiation devices each,and up to as many over door lights as the number of the call initiation devices, for a total maximum support of 48 call devices.The connection shall be made with cat 6 UTP Cable and RJ45 of B Standard. Toatl cable length from the Zone Controller to the last call device Cannot be longer than 500 meters for each communication line oneach communication port.Zone controller shall have 2 power injectors to be included with the device to be used for injecting 12V power to be used on each communication line. Each power injector has 2 RJ% Ports to be connected at suitable location to prevent voltage drops on the lines.Each Power injector require 110-240 V Power.There shall not be any limits to the number of zone controllers that can be used in a nurse call system, they may be placed in the network switch, its connection shall be made with cat 6 UTP cable and RJ% of B Standard.The zone controller shall have 1 port for 110-240 V Power.The zone controller must be configurable from the IP System Controller. ---- etc., complete with all lead | Nos | 85388.34 | 85388.34 | 12.0 | False | None | None | False | None | False | 1024660.08 | 0 | 3091798 | 106301 | None | code180 | Supplying & Fixing of Patch panel for LAN cabling .24 Port 10/100 patch panel ---- etc., complete with all lead | Each | 4983.14 | 4983.14 | 6.0 | False | None | None | False | None | False | 29898.84 | 0 | 3091799 | 106301 | None | code181 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.6Way ---- etc., complete with all lead | Each | 229.75 | 229.75 | 6.0 | False | None | None | False | None | False | 1378.5 | 0 | 3091800 | 106301 | None | code182 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.8 Way ---- etc., complete with all lead | Each | 285.56 | 285.56 | 15.0 | False | None | None | False | None | False | 4283.4 | 0 | 3091801 | 106301 | None | code183 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.10-12Way ---- etc., complete with all lead | Each | 338.78 | 338.78 | 22.0 | False | None | None | False | None | False | 7453.16 | 0 | 3091802 | 106301 | None | code184 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.8 Module ---- etc., complete with all lead | Each | 368.63 | 368.63 | 15.0 | False | None | None | False | None | False | 5529.45 | 0 | 3091803 | 106301 | None | code185 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Supplyin and Fixing Metal Fan Box with Round Hook. ---- etc., complete with all lead | No | 207.68 | 207.68 | 20.0 | False | None | None | False | None | False | 4153.6 | 0 | 3091804 | 106301 | None | code186 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 32-40 A 2 pole ---- etc., complete with all lead | Each | 5917.58 | 5917.58 | 1.0 | False | None | None | False | None | False | 5917.58 | 0 | 3091805 | 106301 | None | code187 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [RCCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 63 A 4 pole ---- etc., complete with all lead | Each | 7197.41 | 7197.41 | 4.0 | False | None | None | False | None | False | 28789.64 | 0 | 3091806 | 106301 | None | code188 | Supplying and drawing 3C x 4 mm2 flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 V as per IS-694:2010 ---- etc., complete with all lead | Mtr | 218.06 | 218.06 | 200.0 | False | None | None | False | None | False | 43612.0 | 0 | 3091807 | 106301 | None | code189 | Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only)45mm dia ---- etc., complete with all lead | Each | 236.0 | 236.0 | 8.0 | False | None | None | False | None | False | 1888.0 | 0 | 3091808 | 106301 | None | code190 | Supplying and fixing of class A (medium duty) GI pipe of wall thick ness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV class. 50mm ---- etc., complete with all lead | Mtr | 493.24 | 493.24 | 10.0 | False | None | None | False | None | False | 4932.4 | 0 | 3091809 | 106301 | None | code191 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sqmm ---- etc., complete with all lead | Each | 14.68 | 14.68 | 2.0 | False | None | None | False | None | False | 29.36 | 0 | 3091810 | 106301 | None | code192 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes.35 sqmm Long Barrel ---- etc., complete with all lead | Each | 37.76 | 37.76 | 6.0 | False | None | None | False | None | False | 226.56 | 0 | 3091811 | 106301 | None | code193 | Earth work excavation for cable trench of 0.5 to 0.75 Mtr Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr,Supplying and Displaying necessary Danger Boards and Lighting, Using sightRails and Sign Boards at every 100 Mtr wherever necessary as directed In soil (hard) ---- etc., complete with all lead | cm | 504.92 | 504.92 | 25.0 | False | None | None | False | None | False | 12623.0 | 0 | 3091812 | 106301 | None | code194 | Supplying and fixing 2mm thick perforated cable tray with powder coated paint on existing MS angle support using necessary Gl bolts/nuts and washer or welding as required 150x50mm ---- etc., complete with all lead | Mtr | 501.5 | 501.5 | 50.0 | False | None | None | False | None | False | 25075.0 | 0 | 3091813 | 106301 | None | code195 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc., 8 SWG-GI Wire ---- etc., complete with all lead | Mtr | 22.42 | 22.42 | 20.0 | False | None | None | False | None | False | 448.4 | 0 | 3091814 | 106301 | None | code196 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc., 8 SWG-Cu Wire ---- etc., complete with all lead | Mtr | 123.9 | 123.9 | 50.0 | False | None | None | False | None | False | 6195.0 | 0 | 3091815 | 106301 | None | code197 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip ---- etc., complete with all lead | Mtr | 88.5 | 88.5 | 5.0 | False | None | None | False | None | False | 442.5 | 0 | 3091816 | 106301 | None | code198 | Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 15 Sweep (450 mm) ---- etc., complete with all lead | Each | 5770.91 | 5770.91 | 4.0 | False | None | None | False | None | False | 23083.64 | 0 | 3091817 | 106301 | None | code199 | Supplying of 5star 1.5 TR split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 Volts with hermetically sealed compressor with air cooled condenser, motor capacitor and start run capacitors, relay and over load protector internal unit, with one indoor and one outdoor unit. The condenser unit will be placed outside the room on the terrace to avoid noise including standard length of suitable size copper tubing covered with insulation tube.(High wall chorded/cordless) suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit. ---- etc., complete with all lead | Each | 61892.53 | 61892.53 | 4.0 | False | None | None | False | None | False | 247570.12 | 0 | 3091818 | 106301 | None | code200 | Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support up to 3.0 ton split/cassette type A/C. ---- etc., complete with all lead | Each | 4121.15 | 4121.15 | 19.0 | False | None | None | False | None | False | 78301.85 | 0 | 3091819 | 106301 | None | code201 | Supplying, erecting, testing and commissioning of voltage stabilizer suitable for 170 to 270 v in put and load variation from no load to full load, with over load protection, spike suppression, operating at 0 C to 40 C. Range etc., complete 3 KVA Capacity ---- etc., complete with all lead | Each | 5185.51 | 5185.51 | 4.0 | False | None | None | False | None | False | 20742.04 | 0 | 3091820 | 106301 | None | code202 | Design, supplying, erecting testing and commissioning of - 20 passenger/ Bed-cum-passenger hospital lift with speed of 1mtr per second, variable voltage variable frequency drive, with or without machine room for the available well size, operating at 415 V 3 phase 50 cycles AC supply, powder coated / Stainless Steel car entrance doors enclosures with suitable colour vinyl flooring, LED car illumination, emergency light, intercom and fan as desired by the user, central opening / side opening door with or without attendant operation, 7 segment display buttons, call register indicator, fireman drive, SS handrails inside car, full length infrared curtain in car door, automatic rescue device with batteries, voice announcing in regional / international languages, Braille buttons with one year warranty and maintenance with necessary scaffolding and minor civil works like fixing of guide rail, counter weight etc.,- 2 Stop/2 Openings without machine room SS finish ---- etc., complete with all lead | Set | 3620847.08 | 3620847.08 | 1.0 | False | None | None | False | None | False | 3620847.08 | 0 | 3091821 | 106301 | None | code203 | Supplying, erecting, testing & commissioning of 1 kVA ON LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. ---- etc., complete with all lead | Each | 30695.1 | 30695.1 | 1.0 | False | None | None | False | None | False | 30695.1 | 0 | 3091822 | 106301 | None | code204 | Supplying, installation, testing & commissioning of 12V DC, 75/80H batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. ---- etc., complete with all lead | Each | 13203.26 | 13203.26 | 2.0 | False | None | None | False | None | False | 26406.52 | 0 | 3091823 | 106301 | None | code205 | Supplying fixing of Network Switches. 16 Port 10/100 Switch ---- etc., complete with all lead | Each | 3180.1 | 3180.1 | 1.0 | False | None | None | False | None | False | 3180.1 | 0 | 3091824 | 106301 | None | code206 | Supplying & Fixing of Patch panel for Lan Cabling. 24 Port 10/100 /1000 Patch Panel ---- etc., complete with all lead | Each | 10254.2 | 10254.2 | 1.0 | False | None | None | False | None | False | 10254.2 | 0 | 3091825 | 106301 | None | code207 | Supplying and drawing PVC flexible 5 pair telepone unarmoured tinned copper cable. ---- etc., complete with all lead | Rmtr | 59.71 | 59.71 | 20.0 | False | None | None | False | None | False | 1194.2 | 0 | 3091826 | 106301 | None | code208 | Supplying and drawing PVC flexible 20 pair telepone unarmoured tinned copper cable. ---- etc., complete with all lead | Mtr | 194.7 | 194.7 | 100.0 | False | None | None | False | None | False | 19470.0 | 0 | 3091827 | 106301 | None | code209 | Supply and Estimation of Telephone Intercom System- 20 Port for internal connection system with all Accessories ---- etc., complete with all lead | Nos | 47200.0 | 47200.0 | 1.0 | False | None | None | False | None | False | 47200.0 | 0 | 3091828 | 106301 | None | code210 | TELEPHONES Analog push button telephone with Caller ID, flash and radial ---- etc., complete with all lead | Nos | 1770.0 | 1770.0 | 6.0 | False | None | None | False | None | False | 10620.0 | 0 | 3091829 | 106301 | None | code211 | Supply, Installation, Testing and Commissioning of Line Interface Unit-6 Port LIU with Coupler and Connector SM Type ---- etc., complete with all lead | Nos | 8850.0 | 8850.0 | 1.0 | False | None | None | False | None | False | 8850.0 | 0 | 3091830 | 106301 | None | code212 | Supplying, installation, testing and commissioning of SITC of complete 32 channel 4K embedded network video recorder,up to 12MP(4K) resolution live view,preview,and play back,full POE Support (for up to 16 channels),internal storage supports 8HDDs expandable up to 64TB (8TB each),operating temperatures(-10 degree C) and (55 degree C),UL,CE,FCC. ---- etc., complete with all lead | Each | 324500.0 | 324500.0 | 1.0 | False | None | None | False | None | False | 324500.0 | 0 | 3091831 | 106301 | None | code213 | Supply and Installation of 6TB Survalance Hard Disk The rate shall include all mounting accessories complete as required ---- etc. ---- etc., complete with all lead | Each | 25960.0 | 25960.0 | 2.0 | False | None | None | False | None | False | 51920.0 | 0 | 3091832 | 106301 | None | code214 | Supply and Installation of 24 Port L2 Managed Poe Switch The rate shall include all mounting accessories complete as required ---- etc., complete with all lead | Each | 38350.0 | 38350.0 | 1.0 | False | None | None | False | None | False | 38350.0 | 0 | 3091833 | 106301 | None | code215 | Supply and Installation of 43LED Monitor The rate shall include all mounting accessories complete as required ---- etc., complete with all lead | Each | 57230.0 | 57230.0 | 2.0 | False | None | None | False | None | False | 114460.0 | 0 | 3091834 | 106301 | None | code216 | Supply and Installation of 2 Mtrs Patch Chord The rate shall include all mounting accessories complete as required ---- etc. ---- etc., complete with all lead | Each | 295.0 | 295.0 | 1.0 | False | None | None | False | None | False | 295.0 | 0 | 3091835 | 106301 | None | code217 | Supply, intallation, testing and Commissioning of 8 Ch Hdmi Switcher ---- etc., complete with all lead | Each | 23600.0 | 23600.0 | 1.0 | False | None | None | False | None | False | 23600.0 | 0 | 3091836 | 106301 | None | code218 | Supply, intallation, testing and Commissioning of Media Converter for OFC Cable ---- etc., complete with all lead | Each | 9263.0 | 9263.0 | 1.0 | False | None | None | False | None | False | 9263.0 | 0 | 3091837 | 106301 | None | code219 | Supply and Installation of LIU For OFC Cable Termination The rate shall include all mounting accessories complete as required ---- etc ---- etc., complete with all lead | Each | 12980.0 | 12980.0 | 1.0 | False | None | None | False | None | False | 12980.0 | 0 | 3091838 | 106301 | None | code220 | Supply, Installation, Testing and Commissioning of 6-core OFC - Armoured outdoor cable (SM) ---- etc., complete with all lead | Mtr | 230.1 | 230.1 | 100.0 | False | None | None | False | None | False | 23010.0 | 0 | 3091839 | 106301 | None | code221 | Supply and Installation of Quad Face Plate Camera Side With IOS The rate shall include all mounting accessories complete as required ---- etc ---- etc., complete with all lead | Each | 295.0 | 295.0 | 12.0 | False | None | None | False | None | False | 3540.0 | 0 | 3091840 | 106301 | None | code222 | Supply and Installation of Fiber Optic Patch Chord for OFC Cable The rate shall include all mounting accessories complete as required ---- etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead | Each | 5664.0 | 5664.0 | 12.0 | False | None | None | False | None | False | 67968.0 | 0 | 3091841 | 106301 | None | code223 | Supply and Installation of Pigtiles For OFC Cable The rate shall include all mounting accessories complete as required- etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead | Each | 1180.0 | 1180.0 | 24.0 | False | None | None | False | None | False | 28320.0 | 0 | 3091842 | 106301 | None | code224 | Providing Compact RMU 11 kV Class SF6/VCB Type (1 Incomer + 3 Breaker + 1 Outgoing) DAS Specification Compact RMU (VCB/SF6 Type) as per IEC-62271 The DAS RMUs shall have the following in addition to the Standards:
DC motors, Numerical Relays, Multi- functional meters, fault passage indicator (FPI), Metering CTs, Protection CTs, Auxiliary transformers, Potential transformer, Batteries, Battery chargers (12 V & 24 V), AC power socket and light for illumination of Control panel. Control cable from each panel shall be wired and terminated to suitable 24 pin connector in the control panel. Suitable space for fixing the Remote Terminal Unit (RTU) and Radio Modem in Control panel. Suitable Clamps for fixing Antenna Pipe 5 Way RMU, 2OD + 3VL (One Incomer + Three Breakers + One Outgoing) 630 Amps with Copper Busbar ---- etc., complete with all lead | Unit | 1592121.61 | 1592121.61 | 1.0 | False | None | None | False | None | False | 1592121.61 | 0 | 3091843 | 106301 | None | code225 | Bed Concreting with CC 1:2:4 M-15 Using 20mm Nominal size graded crushed coarse
aggregates (Extracted from Item No. 2.1.6 of KPWD
SR 2023-24, Volume - 1) ---- etc., complete with all lead | cm | 8103.41 | 8103.41 | 0.44 | False | None | None | False | None | False | 3565.5004 | 0 | 3091844 | 106301 | None | code226 | Providing Reinforecement TMT Fe 550/550D (Extracted from SL No. 69 of KPWD SR 2023-24, Volume - 1) ---- etc., complete with all lead | Kg | 94.75 | 94.75 | 30.0 | False | None | None | False | None | False | 2842.5 | 0 | 3091845 | 106301 | None | code227 | Supplying of Frame of MS Channel 100x50 mm and MS angle 40x40x5 mm welding etc., complete. (Extracted from SL No. 69 of KPWD SR 2023-24, Volume - 1) ---- etc., complete with all lead | Kg | 88.26 | 88.26 | 50.0 | False | None | None | False | None | False | 4413.0 | 0 | 3091846 | 106301 | None | code228 | Rod type earthing with 40 mm Dia, 3 Mtr long MS rod as per specification & drawing including digging of pit & fixing ---- etc., complete with all lead | No | 4051.06 | 4051.06 | 2.0 | False | None | None | False | None | False | 8102.12 | 0 | 3091847 | 106301 | None | code229 | Lettering the RMU with enamel paint and also writing single line diagram of each panel, caution Board, Danger Board etc., including cost of Paint, Brush etc., ---- etc., complete with all lead | No | 1247.38 | 1247.38 | 1.0 | False | None | None | False | None | False | 1247.38 | 0 | 3091848 | 106301 | None | code230 | Earth Excavation for RMU Foundation depositing of earth on bank up to a lead of 50 Mtr and with a lift up to 1.5 Mtr ---- etc., complete with all lead | cm | 340.08 | 340.08 | 1.29 | False | None | None | False | None | False | 438.7032 | 0 | 3091849 | 106301 | None | code231 | Labour charges for Fixing foundation frame of MS channel 100x50 mm and MS angle 40x40x5 mm welding, fixing in concrete, aligning the RMU on foundation bed, assembly of units, connecting Bus Bars from panel to panel etc., complete. ---- etc., complete with all lead | No | 6199.25 | 6199.25 | 4.0 | False | None | None | False | None | False | 24797.0 | 0 | 3091850 | 106301 | None | code232 | Supply, installation, testing and commissioning of 500 kVA , 11kV/433V, 3 phase, 50 Hz, Delta star, DYn11 , outdoor, natually cooled, Oil Immersed copper double wound transformer Conforming to IS: 1180- 1180- 3 LEVEL Contained in mild steel radiator Cooled tank with first fill of oil as per IS: 335 with On load tap changer from +5% to -15% in steps of +/-1.25%, remote tap changes panel with AVR, class F insulation, Rating and Diagram Plate, Earthing Terminals - 2 Nos,Liffting Lugs,Air release hole with plug,Dehydrating Silica Gel Breather,Prismatic Oil level Guage,Oil Conservator with drain plug,Thermometer pocket,Jacking Lugs,Bottom drain cum filter valve,Top filter valve,4 Nos. Bi-Directional rollers,Pressure relief device,Marshalling Box [wherever applicable],100 mm OTI/ 150 mm OTI with alarm & trip,WTI with alarm and trip,Buchholz Relay with alarm and trip,Shut off valves for Buchholz Relay,Magnetic Oil Level guage,Radiators - Fixed / Detachable With HT & LT Cable end boxes / Provison for LV Bus Duct type, The transformer shall have suitable enclosure for providing neutral CT on earthed star point with connector for connection to REF relay provided in Main panel. All routing test as per IS shall be conducted on the transformer. The Transformer Enclosure shall have suitably designed Louvers for Air Circulation & efficient Cooling, required Danger boards, signages, lettering etc.. The enclosure shall be Epoxy Powder coated. The transformer shall be subjected to all routine tests as per IS/IEC standards. Type test certificate shall be submitted (As Per EC BC Norms) ---- etc., complete with all lead | Each | 1186085.14 | 1186085.14 | 3.0 | False | None | None | False | None | False | 3558255.42 | 0 | 3091851 | 106301 | None | code233 | Supply & Making of 11KV (E) Extruded X linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Outdoor ---- etc., complete with all lead | Set | 5278.97 | 5278.97 | 2.0 | False | None | None | False | None | False | 10557.94 | 0 | 3091852 | 106301 | None | code234 | Supply & Making of 11KV (E) Extruded X linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Indoor ---- etc., complete with all lead | Set | 4073.12 | 4073.12 | 4.0 | False | None | None | False | None | False | 16292.48 | 0 | 3091853 | 106301 | None | code235 | 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND
WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. 95 Sqmm, (54 GI Wires - 2.5 mm Dia) ---- etc., complete with all lead | Km | 1154786.47 | 1154786.47 | 0.35 | False | None | None | False | None | False | 404175.2645 | 0 | 3091854 | 106301 | None | code236 | 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND
WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. 240 Sqmm, (55 GI Wires - 3.15 mm Dia) ---- etc., complete with all lead | Km | 2149550.3 | 2149550.3 | 0.35 | False | None | None | False | None | False | 752342.605 | 0 | 3091855 | 106301 | None | code237 | 11 kV, Jointing & Cable Termination Kit as per IS-13573 Heat Shrinkable Type Transition Jointing Kit for XLPE Cable 3x240 Sqmm ---- etc., complete with all lead | Set | 16437.87 | 16437.87 | 2.0 | False | None | None | False | None | False | 32875.74 | 0 | 3091856 | 106301 | None | code238 | Heat Shrinkable Outdoor Type Cable Termination Kit for XLPE Cable 3x240 Sqmm ---- etc., complete with all lead | Set | 6902.76 | 6902.76 | 2.0 | False | None | None | False | None | False | 13805.52 | 0 | 3091857 | 106301 | None | code239 | Heat Shrinkable Indoor Type Cable Termination Kit for XLPE Cable ---- etc., complete with all lead | Set | 6088.92 | 6088.92 | 2.0 | False | None | None | False | None | False | 12177.84 | 0 | 3091858 | 106301 | None | code240 | Providing chain link fencing 50 mm size of 8 guage properly stretched between rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be welded to the Pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts, cutting, bending wherever necessary,
wastage and lapping etc., complete as per the direction of the engineer incharge for work including two coats of approved quality paint over one coat of primer paint. ---- etc., complete with all lead | Sqm | 1281.13 | 1281.13 | 325.0 | False | None | None | False | None | False | 416367.25 | 0 | 3091859 | 106301 | None | code241 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete with all lead | Each | 625.93 | 625.93 | 12.0 | False | None | None | False | None | False | 7511.16 | 0 | 3091860 | 106301 | None | code242 | Supplying, installing, testing and commissioning of 320KVA/256kw Diesel Generator,Prime duty generator set compliance to CPCB BS-IV+ Norms with alternator of similar capacity with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specificationsEngine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046, As per CPCB BS-IV+ Norms. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with Electronic governor suitable for synchronizing operations, G2 Class Governing. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Silencer specifically tuned to EATS,Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming toIS/IEC 60034-1. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have + 1.0 % Voltage regulation (max) in static conditions- IP: 23 protections with insulation class H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads, The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight. Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,- Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode. Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA @ 1mtr at 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at rated load made on special purpose CNC machines for consistency in quality and workmanship, Powder coated for long lasting service life and superior finish, With UV resistant powder coating, can withstand extreme environment,Use of special hardware for longer life, Insulation material meets exacting IS 8183 specifications for better sound attenuation, Flush styling - no projections, Fluid drains for lube oil and fuel, Fuel filling point inside the enclosure. ---- etc., complete with all lead | Set | 3744140.0 | 3744140.0 | 2.0 | False | None | None | False | None | False | 7488280.0 | 0 | 3091861 | 106301 | None | code243 | Supplying, installing, testing and commissioning of 250KVA/200kw Diesel Generator,Prime duty generator set compliance to CPCB BS-IV+ Norms with alternator of similar capacity with following specifications. Power rating as per standard reference condition specifically tuned to EATS,Dry type air cleaner, regulated through an AVR. The alternator shall have + 1.0 % Voltage regulation (max) in static conditions- IP: 23 protections with insulation class H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads, Base frame with integral fuel tank and DEF tank is provided with drain plug, air vent, inlet and outlet connection and provision for cleaning. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lamps for ‘Load On’ and ‘Set Running’, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight. Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,- Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode. Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA @ 1mtr at 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at rated load made on special purpose CNC machines for consistency in quality and workmanship, Powder coated for long lasting service life and superior finish, With UV resistant powder coating, can withstand extreme environment,Use of special hardware for longer life, Insulation material meets exacting IS 8183 specifications for better sound attenuation, Flush styling - no projections, Fluid drains for lube oil and fuel, Fuel filling point inside the enclosure. ---- etc., complete with all lead | Set | 2657360.0 | 2657360.0 | 1.0 | False | None | None | False | None | False | 2657360.0 | 0 | 3091862 | 106301 | None | code244 | Supply, Erection, testing and commissioning of AMF panel suitable for .....KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .....amps 4 pole contactor for alternator with thermal O/L relay,..... Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, ....capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Battery charger unit with inbuilt Auto/Manual and flat/Boost facility. 250 KVA ---- etc., complete with all lead | Each | 364800.3 | 364800.3 | 1.0 | False | None | None | False | None | False | 364800.3 | 0 | 3091863 | 106301 | None | code245 | Supply, Erection, testing and commissioning of AMF panel suitable for .....KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .....amps 4 pole contactor for alternator with thermal O/L relay,..... Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, ....capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Battery charger unit with inbuilt Auto/Manual and flat/Boost facility. 320 KVA to 400 KVA ---- etc., complete with all lead | Each | 406028.68 | 406028.68 | 2.0 | False | None | None | False | None | False | 812057.36 | 0 | 3091864 | 106301 | None | code246 | Supply & installation of exhaust gas piping of suitable diameter as per manufactures standard welded black MS, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti- vibration mountings, insulation of exhaust system with mineral wool / Rockwool, 50mm thick wire mesh & aluminum cladding etc. ---- etc., complete with all lead | m | 9440.0 | 9440.0 | 220.0 | False | None | None | False | None | False | 2076800.0 | 0 | 3091865 | 106301 | None | code247 | Supply and installing of DG set stack using angular structure, channel, necessary nut and bolt and all required accessories for erecting exhaust pipe from 2 nos DG set and space provision for provinding exhaust pipe for 2 more DG set in future. The design of the stack with foundation shall be got approved before fabrication. The foundation for the stack shall be measured separately. ---- etc., complete with all lead | Kg | 236.0 | 236.0 | 4000.0 | False | None | None | False | None | False | 944000.0 | 0 | 3091866 | 106301 | None | code248 | Supplying and fixing of 630A.50KA,Motorised Air Circuit Breaker (ACB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu lcs) ---- etc., complete with all lead | Each | 123900.0 | 123900.0 | 3.0 | False | None | None | False | None | False | 371700.0 | 0 | 3091867 | 106301 | None | code249 | PLC Control:-Supply, Erection, testing and commissioning of Automatic syncronisation with load sharing,RPR,REF,MDM with suitable CTs,Hardware interlocking through Aux contactor with timers , UV and OV, Annunciator, Programmable logic controller 24IP and 24OP,Battery charger,Relay board,AC and DC indicating lamp,Auto sync Relay along with control wiring. ---- etc., complete with all lead | Each | 236000.0 | 236000.0 | 1.0 | False | None | None | False | None | False | 236000.0 | 0 | 3091868 | 106301 | None | code250 | Supply and laying of 2Cx2.5SQ MM and 6CX2.5 SQ MM Sheilded Sensor and control Cables ---- etc., complete with all lead | Mtr | 236.0 | 236.0 | 500.0 | False | None | None | False | None | False | 118000.0 | 0 | 3091869 | 106301 | None | code251 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, junction boxes adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and Rcc wall/ stone structure or rawl plugs in case of brick wall and cement plastering the damaged portion using heavy guage saddles at an interval of 700mm using NF screws 32 mm dia 2 mm thick. ---- etc., complete with all lead | Mtr | 133.69 | 133.69 | 2000.0 | False | None | None | False | None | False | 267380.0 | 0 | 3091870 | 106301 | None | code252 | Supplying and drawing Flexible Multi core Cable manufactured with electrolytic grade flexible copper with low conductor confirming toIS8130-1984and(Virgin)PVC insulation sheathed suitable for working voltage upto 1100V as per IS 694:2010 3CX1.5 mm2 ---- etc., complete with all lead | Mtr | 93.46 | 93.46 | 500.0 | False | None | None | False | None | False | 46730.0 | 0 | 3091871 | 106301 | None | code253 | Supplying and drawing Flexible Multi core Cable manufactured with electrolytic grade flexible copper with low conductor confirming toIS8130-1984and(Virgin)PVC insulation sheathed suitable for working voltage upto 1100V as per IS 694:2010 3CX2.5 mm2 ---- etc., complete with all lead | Mtr | 146.67 | 146.67 | 500.0 | False | None | None | False | None | False | 73335.0 | 0 | 3091872 | 106301 | None | code254 | Supplying ...litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate .2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting.25Litres ---- etc., complete with all lead | Each | 13294.12 | 13294.12 | 10.0 | False | None | None | False | None | False | 132941.2 | 0 | 3091873 | 106301 | None | code255 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCBs single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure I - Double Door 8 Way SP & N ---- etc., complete with all lead | Each | 1936.62 | 1936.62 | 10.0 | False | None | None | False | None | False | 19366.2 | 0 | 3091874 | 106301 | None | code256 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40Amps TPN ---- etc., complete with all lead | Each | 959.22 | 959.22 | 20.0 | False | None | None | False | None | False | 19184.4 | 0 | 3091875 | 106301 | None | code257 | Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 63mm dia ---- etc., complete with all lead | Each | 251.81 | 251.81 | 16.0 | False | None | None | False | None | False | 4028.96 | 0 | 3091876 | 106301 | None | code258 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 25 sqmm Long Barrel ---- etc., complete with all lead | Each | 25.96 | 25.96 | 24.0 | False | None | None | False | None | False | 623.04 | 0 | 3091877 | 106301 | None | code259 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc., 8 SWG-GI Wire ---- etc., complete with all lead | Mtr | 24.66 | 24.66 | 1000.0 | False | None | None | False | None | False | 24660.0 | 0 | 3091878 | 106301 | None | code260 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 40x6mm Copper strip ---- etc., complete with all lead | Mtr | 1427.8 | 1427.8 | 150.0 | False | None | None | False | None | False | 214170.0 | 0 | 3091879 | 106301 | None | code261 | Supplying of…TR split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 Volts with hermetically sealed compressor with air cooled condenser, motor capacitor and start run capacitors, relay and over load protector internal unit, with one indoor and one outdoor unit. The condenser unit will be placed outside the room on the terrace to avoid noise including standard length of suitable size copper tubing covered with insulation tube.(High wall chorded/cordless) suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit. 5 Star 2 ton capacity ---- etc., complete with all lead | Each | 70154.3 | 70154.3 | 15.0 | False | None | None | False | None | False | 1052314.5 | 0 | 3091880 | 106301 | None | code262 | Supplying, erecting, testing and commissioning of voltage stabilizer suitable for 170 to 270 v in put and load variation from no load to full load, with over load protection, spike suppression, operating at 00 C to 400 C. Range etc., complete. 4 KVA Capacity ---- etc., complete with all lead | Each | 6220.02 | 6220.02 | 15.0 | False | None | None | False | None | False | 93300.3 | 0 | 3091881 | 106301 | None | code263 | Supply erection,testing,commissioning of Cassette type split
Air conditioners suitable for operation on single/three phase
AC supply,hermetically sealed compressor with aircooled
condenser motor capacitor start,capacitors run relayand
overload protection,one ceiling mounted indoor unit and
one outdoor condenser unit including standard accessories
covered with insulation tube including battery operated
cordless unit. 3.0 TR Cassette 3 Ph ---- etc., complete with all lead | Each | 136441.87 | 136441.87 | 10.0 | False | None | None | False | None | False | 1364418.7 | 0 | 3091882 | 106301 | None | code264 | Supplyingandinstallationofinsulatedrefrigerantcopper tubingof5/8and3/8withpolythenefoaminsulation3 core80standcopperwiringbetweenindoorandoutdoor unitLeaktestingoilandgaschargingforadditionalpiping length of tube. Cassette ---- etc., complete with all lead | Mtr | 2127.42 | 2127.42 | 200.0 | False | None | None | False | None | False | 425484.0 | 0 | 3091883 | 106301 | None | code265 | 2 mm thick perforated cable GI tray with on esisting Ms angle support using necessary GI bolts/nuts and washer or welding as required. 150 x 50 mm ---- etc., complete with all lead | Mtr | 600.97 | 600.97 | 1000.0 | False | None | None | False | None | False | 600970.0 | 0 | 3091884 | 106301 | None | code266 | 2 mm thick perforated cable GI tray with on esisting Ms angle support using necessary GI bolts/nuts and washer or welding as required. 1300 x 50 mm ---- etc., complete with all lead | Mtr | 761.93 | 761.93 | 500.0 | False | None | None | False | None | False | 380965.0 | 0 | 3091885 | 106301 | None | code267 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 90watts ---- etc., complete with all lead | No | 11500.28 | 11500.28 | 10.0 | False | None | None | False | None | False | 115002.8 | 0 | 3091886 | 106301 | None | code268 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48 Sweep 5 Star (1200 mm) ---- etc., complete with all lead | Each | 3474.75 | 3474.75 | 150.0 | False | None | None | False | None | False | 521212.5 | 0 | 3091887 | 106301 | None | code269 | Supplying A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.100 A 4 x 30 x 6 mm Copper Strips ---- etc., complete with all lead | Mtr | 7080.0 | 7080.0 | 35.0 | False | None | None | False | None | False | 247800.0 | 0 | 3091888 | 106301 | None | code270 | Supplying A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.250 A 4 x 30 x 10 mm Copper Strips ---- etc., complete with all lead | Mtr | 11800.0 | 11800.0 | 25.0 | False | None | None | False | None | False | 295000.0 | 0 | 3091889 | 106301 | None | code271 | Supplying A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.400 A 4 x 50 x 10 mm Copper Strips ---- etc., complete with all lead | Mtr | 15340.0 | 15340.0 | 15.0 | False | None | None | False | None | False | 230100.0 | 0 | 3091890 | 106301 | None | code272 | Supplying and fixing undrilled Adopter suitable for 100A to 250A MCCBs ---- etc., complete with all lead | Each | 23600.0 | 23600.0 | 48.0 | False | None | None | False | None | False | 1132800.0 | 0 | 3091891 | 106301 | None | code273 | Supplying and fixing undrilled Adopter suitable for 250A to 400A MCCBs ---- etc., complete with all lead | Each | 35400.0 | 35400.0 | 6.0 | False | None | None | False | None | False | 212400.0 | 0 | 3091892 | 106301 | None | code274 | Supplying and fixing undrilled bus bar suitable for 100A to 400A MCCBs(RYB) ---- etc., complete with all lead | Mtr | 9440.0 | 9440.0 | 50.0 | False | None | None | False | None | False | 472000.0 | 0 | 3091893 | 106301 | None | code275 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE 250Amps 36kA ---- etc., complete with all lead | Each | 30561.41 | 30561.41 | 4.0 | False | None | None | False | None | False | 122245.64 | 0 | 3091894 | 106301 | None | code276 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE 400 Amps 36kA ---- etc., complete with all lead | Each | 36624.37 | 36624.37 | 4.0 | False | None | None | False | None | False | 146497.48 | 0 | 3091895 | 106301 | None | code277 | Supplying and fixing of 800A.50KA,Motorised Air Circuit Breaker (ACB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu lcs) ---- etc., complete with all lead | Each | 141600.0 | 141600.0 | 4.0 | False | None | None | False | None | False | 566400.0 | 0 | 3091896 | 106301 | None | code278 | Supplying and fixing of 400A.50KA,Motorised Air Circuit Breaker (ACB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu lcs) ---- etc., complete with all lead | Each | 82600.0 | 82600.0 | 2.0 | False | None | None | False | None | False | 165200.0 | 0 | 3091897 | 106301 | None | code279 | PLC Control:-Supply, Erection, testing and commissioning of Automatic syncronisation with load sharing,RPR,REF,MDM with suitable CTs,Hardware interlocking through Aux contactor with timers , UV and OV, Annunciator, Programmable logic controller 24IP and 24OP,Battery charger,Relay board,AC and DC indicating lamp,Auto sync Relay along with control wiring. ---- etc., complete with all lead | Each | 295000.0 | 295000.0 | 1.0 | False | None | None | False | None | False | 295000.0 | 0 | 3091898 | 106301 | None | code280 | Supply of 08 KVA Isolated Power Distribution panel for OT with Online monitoring, with fault location and with Programmable Remote Alarm Indicator :
Electrical Safety system: IEC 60364-7-710: Electrical installation ofbuildings-Requirements for special installations for medical locations ( Group-2) and Indian NEC- SP-30- Section 4, 2011, provision P5 requires unearthed(IT) system for all critical medical locations ( O.T, I.C.U, I.C.C.U, PrematureBaby Room etc). Therefore, an Electrical Safety Alarm System shall beinstalled to ensure patient and employee safety against risk of electrical shock, fire and damage of electrical insulation used in equipment and powerdistribution circuits. The system shall provide perfect ungrounded powersupply system in OT; ensure no fire, no electrical spark, no MCB tripping evenin case of 1st insulation fault (BIS NEC-SP-30 , P5 location requirement);ensure 24X7 Insulation monitoring of entire electrical distribution system &an audio visual remote and local alarm even in case of 1st fault; never give anyspurious alarm / false alarm, fool proof against EMI/EMC effects; should havea system to identify faulty feeder / socket / equipment online without trippingthe system; a periodic self diagnostic features to identify malfunctions in thesystem itself. Insulation monitoring devices using a Active measuring principle in compliance with IEC 61557-8&IEC-60364-7-710 should be used.Insulation monitor shall have facility to monitor over current and temperature monitoring facility of the Isolation transformer.Fault Location system should be in accordance with IEC 61557-9 & IEC 60364-7-710. a.An Isolation Transformer 10KVA max as per IEC-61558-2 & IEC-60364-7-710 along with insulation monitoring device& fault location system shall be provided as mentioned above. Supplier/ Vender to quote necessary hardware to fulfill the requirement. b.A complete panel consisting of all items along with indicating lamp for (Mains On, Healthy & Faulty condition), MCBs, Exhaust Fan and air filter shall be supplied. All internal wiring should terminate in connectors with screw and clampspring connections of the Klippon type mounted, on a DIN rail and labeledwith indelible proprietary labels. Individual fuses or miniature circuitbreakers should protect all internal circuits. All internal wiring should be ofthe high temperature type and enclosed in propriety ducting or mini. Allinternal wires should be marked with plastic ferrule type cable markers, forease of identification.Bender Make or Equivalent. ---- etc., complete with all lead | Each | 1239000.0 | 1239000.0 | 3.0 | False | None | None | False | None | False | 3717000.0 | 0 | 3091899 | 106301 | None | code281 | Supplying and fixing Parallel Connectors for (500mm air terminal) connecting two conductors in parallel manner. Material- StSt, with clamping range- Rd / Rd 7-10 mm & Complied as per Standard EN 62561-1. ---- etc., complete with all lead | Nos | 1413.64 | 1413.64 | 16.0 | False | None | None | False | None | False | 22618.24 | 0 | 3091900 | 106301 | None | code282 | Supplying and fixing Air-termination rod having length- 3000 mm, of Material- AlMgSi, of Diameter 16 / 10 mm, chamfered on both ends & Complied as per Standard EN 62561-2. ---- etc., complete with all lead | Nos | 5607.36 | 5607.36 | 9.0 | False | None | None | False | None | False | 50466.24 | 0 | 3091901 | 106301 | None | code283 | Supplying and fixing Side Wall Clamp for air terminal, Material - StSt 304 Clamping range - 16/10 mm. ---- etc., complete with all lead | Nos | 2102.76 | 2102.76 | 12.0 | False | None | None | False | None | False | 25233.12 | 0 | 3091902 | 106301 | None | code284 | Supplying and fixing Air-termination rod clamps for connecting air-termination rods with one or two conductors. Material of clamp Al, with clamping range of air-termination rod 16 mm and Clamping range of conductor Rd 2x 8-10 mm & Complied as per Standard EN 62561-1. ---- etc., complete with all lead | Nos | 830.72 | 830.72 | 6.0 | False | None | None | False | None | False | 4984.32 | 0 | 3091903 | 106301 | None | code285 | Supplying and fixing MV clamp with hexagon screw, StSt MV clamp Multipurpose connecting clamp for universal use as a cross clamp, T clamp and parallel clamp, for round conductors ---- etc., complete with all lead | Nos | 988.84 | 988.84 | 60.0 | False | None | None | False | None | False | 59330.4 | 0 | 3091904 | 106301 | None | code286 | Supplying and fixing Connecting Sleeves for longitudinal connection of two round conductors with four screws. Material of clamp- Al, Clamping range- Rd 8 mm & Complied as per Standard EN 62561-1. ---- etc., complete with all lead | Nos | 624.22 | 624.22 | 150.0 | False | None | None | False | None | False | 93633.0 | 0 | 3091905 | 106301 | None | code287 | Supplying and fixing Roof Conductor of Diameter - 8 mm, Cross-section- 50 mm2, of Material- AlMgSi & Complied as per Standard EN 62561-2. ---- etc., complete with all lead | Mtr | 410.64 | 410.64 | 750.0 | False | None | None | False | None | False | 307980.0 | 0 | 3091906 | 106301 | None | code288 | Supplying and fixing Roof conductor holder FB2 for flat roofs with concrete block-C35/45 with double conductor holder- Rd 8 mm fixed, Dimension- 141 x 86 x 70 mm. ---- etc., complete with all lead | Nos | 440.14 | 440.14 | 35.0 | False | None | None | False | None | False | 15404.9 | 0 | 3091907 | 106301 | None | code289 | Supplying and fixing Conductor holder for Parapet wall/Side wall. Having height- 16 mm, Thread of conductor holder- M8, Material of conductor holder- plastic, Conductor leading- loose, Conductor holder support Rd- 8 mm With accessories Screw and Gitty, Material SS (M5 x 50mm) ---- etc., complete with all lead | Nos | 278.48 | 278.48 | 750.0 | False | None | None | False | None | False | 208860.0 | 0 | 3091908 | 106301 | None | code290 | Supplying and fixing Down Conductor of Diameter - 8 mm, Cross-section- 50 mm2, of Material- AlMgSi & Complied as per Standard EN 62561-2. ---- etc., complete with all lead | Mtr | 427.16 | 427.16 | 680.0 | False | None | None | False | None | False | 290468.8 | 0 | 3091909 | 106301 | None | code291 | Supplying and fixing Conductor holder for Parapet wall/Side wall. Having height- 16 mm, Thread of conductor holder- M8, Material of conductor holder- plastic, Conductor leading- loose, Conductor holder support Rd- 8 mm With accessories Screw and Gitty, Material SS (M5 x 50mm) ---- etc., complete with all lead | Nos | 311.52 | 311.52 | 680.0 | False | None | None | False | None | False | 211833.6 | 0 | 3091910 | 106301 | None | code292 | Supplying and fixing Lightning strike counter, Lightning strike counter for digitally recording impulse currents. The counter is preferably installed on the down conductors of the lightning protection system or between the equipotential bonding bar and the earth- termination system. ---- etc., complete with all lead | Nos | 63853.34 | 63853.34 | 1.0 | False | None | None | False | None | False | 63853.34 | 0 | 3091911 | 106301 | None | code293 | Supplying and fixing UNI Disconnecting Clamps with intermediate plate for round and flat conductor of Material- StSt, Material thickness- 2.5 mm, with clamping range- Rd / Fl 8-10 / 30 mm, & Complied as per Standard EN 62561-1. ---- etc., complete with all lead | Nos | 1477.36 | 1477.36 | 35.0 | False | None | None | False | None | False | 51707.6 | 0 | 3091912 | 106301 | None | code294 | Supplying and fixing GI flat (25x6mm) Strip. Having width- 25mm, Thickness- 6mm, Material- Hot dipped Galvanized Iron, Cross Section- 150 mm2 Coating thickness- Avg. 70 microns. & Complied as per IEC 62561-2. ---- etc., complete with all lead | Mtr | 640.74 | 640.74 | 170.0 | False | None | None | False | None | False | 108925.8 | 0 | 3091913 | 106301 | None | code295 | Supplying and fixing GI strip holder of material- Dow moulded compound, having height- 19mm, Slot Size- 25x6 mm. ---- etc., complete with all lead | Nos | 772.9 | 772.9 | 70.0 | False | None | None | False | None | False | 54103.0 | 0 | 3091914 | 106301 | None | code296 | Supplying and fixing Copper bonded rod with Low carbon steel, high tensile strength copper bonded rod with min 254 microns of copper plating, UL listed with company name marked on rod. Diameter- 17.2 mm, Length- 3 meters, Material- Copper Bonded, Coating thickness- 250 microns, min, Approvals- Tested acc. IEC / EN 62561-2, UL 467. ---- etc., complete with all lead | Nos | 11742.18 | 11742.18 | 70.0 | False | None | None | False | None | False | 821952.6 | 0 | 3091915 | 106301 | None | code297 | Supplying and fixing StSt 316 grade clamp to terminate the load on earth electrode. Dimension- 160x35x3 mm. ---- etc., complete with all lead | Nos | 1642.56 | 1642.56 | 35.0 | False | None | None | False | None | False | 57489.6 | 0 | 3091916 | 106301 | None | code298 | Supplying and fixing Poly plastic pit cover of material- Polymer Body & Cover, Product Code- HEP, Dimensions- 308 mm (L) x 308 mm (W) X 214 mm (H), Weight 2.5 kg (5.50 LBS). ---- etc., complete with all lead | Nos | 4106.4 | 4106.4 | 35.0 | False | None | None | False | None | False | 143724.0 | 0 | 3091917 | 106301 | None | code299 | Supply, Installation Testing and commissioning of double convertsion, DSP Based, True on line 15KVA UPS system with 415V +/- 15% V,50Hz,3Ph Input & 415V+/-1%, 50 Hz ,3Ph Output, With Output 0.9 PF, working on 16 Bit microprocessor Architecture,Isolation transformers, RS 232 ports, monitoring software , O/L, SC. protections & self diagnostic features, LCD Display Panel for Functions & all parameters, complying with IEC standards. Convertors, Invertors & Battery Charger shall utilize PWM technology with IGBT. Battery Back up time of 30 minutes back up on 15kva load with required VRLA SMF individual Battery bank System, housed in suitable Cabinet /Rack, Static ByPass, complete with Internal wiring & all accessories to be provided. The System shall have in-built P.F.correction & shall ensure THD as per latest International standards. The efficiency of UPS shall be 96% or more. ---- etc., complete with all lead | Each | 377600.0 | 377600.0 | 2.0 | False | None | None | False | None | False | 755200.0 | 0 | 3091918 | 106301 | None | code300 | Supplying & Fixing of switch mounting rack with power manager & Cable manager as per standard specification 6U with 450mm depth ---- etc., complete with all lead | Each | 9056.15 | 9056.15 | 10.0 | False | None | None | False | None | False | 90561.5 | 0 | 3091919 | 106301 | None | code301 | Supplying fixing of Network Switches. 8 port 10/100 Switch ---- etc., complete with all lead | Each | 1362.9 | 1362.9 | 4.0 | False | None | None | False | None | False | 5451.6 | 0 | 3091920 | 106301 | None | code302 | Supplying & Fixing of Patch panel for LAN cabling .24 Port 10/100 patch panel ---- etc., complete with all lead | Each | 5321.8 | 5321.8 | 2.0 | False | None | None | False | None | False | 10643.6 | 0 | 3091921 | 106301 | None | code303 | Supply and Installation of Micro controller based Indication wall Mount panel With the following facilities:-
3 Digit room display
Reset switch
Relay logic switch
Voice recording module
Mute switch
Battery management circuit
Wall mounting type enclosure
RS 485 networking chord
The rate shall include all mounting accessories complete as required ---- etc., complete with all lead | Nos | 94928.64 | 94928.64 | 3.0 | False | None | None | False | None | False | 284785.92 | 0 | 3091922 | 106301 | None | code304 | Supply and Installation of Call unit with Switches like
Membrane Type Call Switches with bell indicator
LED Indicator
Membrane Type Reset Switch
Compatible for hand held call unit
Mounted On Standard electrical 2 module plate near the Bed ---- etc., complete with all lead | Nos | 2940.56 | 2940.56 | 50.0 | False | None | None | False | None | False | 147028.0 | 0 | 3091923 | 106301 | None | code305 | Pull Cord Units for Nurse Call System with Corridor Indicator. ---- etc., complete with all lead | Nos | 5900.0 | 5900.0 | 10.0 | False | None | None | False | None | False | 59000.0 | 0 | 3091924 | 106301 | None | code306 | Call station with zone selector & all Facility with goose neck microphone for 12zones ---- etc., complete with all lead | Nos | 14160.0 | 14160.0 | 6.0 | False | None | None | False | None | False | 84960.0 | 0 | 3091925 | 106301 | None | code307 | Supply, installation, testing and commissioning of booster amplifier with power handling of 250 to 300 watt RMS 4ohms Dual and 100/70 volt output on bridge mode single channel Rack mountable Specs: frequency response: 20 htz to 20khtz ---- etc., complete with all lead | No | 33040.0 | 33040.0 | 5.0 | False | None | None | False | None | False | 165200.0 | 0 | 3091926 | 106301 | None | code308 | Supply, installation,testing and commissioning professional grade 2.5 sqmm TIN coated low loss 2 core multi strand Oxidation Free speaker cable including, lead and lifts, loading and unloading,cost of conveyance for all the materials with the accessories ---- etc., complete with all lead | Mtr | 44.84 | 44.84 | 3500.0 | False | None | None | False | None | False | 156940.0 | 0 | 3091927 | 106301 | None | code309 | Supply, installation, testing and commissioning of professional grade audio connectors for inter connection cables with in the rack and other units as well auditorium as required including charges for labour, lead and lifts, loading and unloading, cost of conveyance for all the materials with the accessories required for completion as per the detailed specifications ---- etc., complete with all lead | Set | 472.0 | 472.0 | 20.0 | False | None | None | False | None | False | 9440.0 | 0 | 3091928 | 106301 | None | code310 | Supply, installation, testing and commissioning of compact ceiling speaker with power handling up to 6 Watt RMS 0/100volt@ 1456 ohms single channel. selectable taping Specs: Power handling ---- etc., complete with all lead | No | 1121.0 | 1121.0 | 90.0 | False | None | None | False | None | False | 100890.0 | 0 | 3091929 | 106301 | None | code311 | Vedio (Lecture Hall ) SITC of Projector with Laser - Light Output: 5000 ANSI Lumens or more Native Resolution: WUXGA or better Video Input: HDMI, Composite video input, S-Video Input, VGA Audio Input:Stereo 3.5mm mini jack Control terminals: USB v2.0 or higher, RJ-45, RS 232C Lamp: 400W Lamp life: 12000 hours or more Accessories:Including but not limited to Power cables, Remote control, Dust cover, ceiling mount and other accessories etc Warranty: 10000 hrs or 3 years on the projector including the lamp/light source. Comprehensive on-site service warranty for all the parts of the projector including lamp/light source. Brightness not less than 75% of the stated value till the end of the warranty period. , complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead | Nos | 454300.0 | 454300.0 | 1.0 | False | None | None | False | None | False | 454300.0 | 0 | 3091930 | 106301 | None | code312 | SITC of (Lecture Hall )Motorised Projection Screen Remote operated Image Size: 9ft X 12ft Gain: 1 ., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead | Nos | 129800.0 | 129800.0 | 1.0 | False | None | None | False | None | False | 129800.0 | 0 | 3091931 | 106301 | None | code313 | Supply installation, testing and commissioning of Popup Boxes. ---- etc., complete with all lead | No | 11623.0 | 11623.0 | 1.0 | False | None | None | False | None | False | 11623.0 | 0 | 3091932 | 106301 | None | code314 | Supply installation, testing, Equalizaton & comissioning of HDMI Cables 10Mtr as per site condition. The unit shall be a HDMI cables v.4 certified and transmit high-definition digital audio and video signals without quality loss or distortion. The cables feature high-purity copper, gold plated connectors and tin plated conduits all securely welded and fully is a plug and play range of high definition Exceptional high-speed performance for 1080p displays, with 3D displays and 4K compatibility High definition metal plug Perfect opaque plug end as well as excellent conductivity and protection against oxidation. 1080p 36bit Deep Colour @ 60 fps Video Format Supported:VESA:640x480,800x600, \1024x768,1280x1024, 1600x1200,1920x1200DTV/HDTV:480i/576i/480p/576p/720p/1080i/1080p Output Video: HDMI v1.4 with full 3D compatibility with Frame packing/sequential (Blu-ray) and Interlaced Stereoscopic (satellite/cable broadcasts) Audio Format Supported: DTS-HD, Dolby True HD, multi-channel 5.1, 7.1, stereo - S/PDIF Audio: Dolby Digital PCM 5.1 ---- etc., complete with all lead | Lot | 17700.0 | 17700.0 | 1.0 | False | None | None | False | None | False | 17700.0 | 0 |
| 1710501218000 | 0 | None | None | Buildings | Water supply & sanitary work | 40088707.18 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3091933 | 106302 | None | code01 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 40mm dia pipes, From wash basin waste lines(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | m | 394.59 | 394.59 | 220.0 | False | None | None | False | None | False | 86809.8 | 0 | 3091934 | 106302 | None | code02 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 50mm dia pipes, From sink & urinal waste lines(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | m | 501.03 | 501.03 | 110.0 | False | None | None | False | None | False | 55113.3 | 0 | 3091935 | 106302 | None | code03 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (Internal drainage) 75mm nominal dia pipes (BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | m | 375.12 | 375.12 | 635.0 | False | None | None | False | None | False | 238201.2 | 0 | 3091936 | 106302 | None | code04 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipes (BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | m | 499.73 | 499.73 | 595.0 | False | None | None | False | None | False | 297339.35 | 0 | 3091937 | 106302 | None | code05 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | m | 255.71 | 255.71 | 290.0 | False | None | None | False | None | False | 74155.9 | 0 | 3091938 | 106302 | None | code06 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | m | 351.76 | 351.76 | 825.0 | False | None | None | False | None | False | 290202.0 | 0 | 3091939 | 106302 | None | code07 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 1583.56 | 1583.56 | 34.0 | False | None | None | False | None | False | 53841.04 | 0 | 3091940 | 106302 | None | code08 | Providing and fixing C.P. brass angle valve for basin mixer and geyser
points of approved quality conforming to IS:8931(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 804.76 | 804.76 | 90.0 | False | None | None | False | None | False | 72428.4 | 0 | 3091941 | 106302 | None | code09 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 6279.72 | 6279.72 | 35.0 | False | None | None | False | None | False | 219790.2 | 0 | 3091942 | 106302 | None | code10 | Providing and fixing CP brass toilet paper holder(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 738.96 | 738.96 | 34.0 | False | None | None | False | None | False | 25124.64 | 0 | 3091943 | 106302 | None | code11 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: One urinal basin with 5 litre white P.V.C. automatic flushing cistern(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 5781.29 | 5781.29 | 10.0 | False | None | None | False | None | False | 57812.9 | 0 | 3091944 | 106302 | None | code12 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 941.05 | 941.05 | 38.0 | False | None | None | False | None | False | 35759.9 | 0 | 3091945 | 106302 | None | code13 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 4000.44 | 4000.44 | 20.0 | False | None | None | False | None | False | 80008.8 | 0 | 3091946 | 106302 | None | code14 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge.(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 1051.38 | 1051.38 | 34.0 | False | None | None | False | None | False | 35746.92 | 0 | 3091947 | 106302 | None | code15 | Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore)(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 107.73 | 107.73 | 46.0 | False | None | None | False | None | False | 4955.58 | 0 | 3091948 | 106302 | None | code16 | Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 397.19 | 397.19 | 30.0 | False | None | None | False | None | False | 11915.7 | 0 | 3091949 | 106302 | None | code17 | Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 15 mm nominal bore, weighing not less than 32 g (BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 83.07 | 83.07 | 26.0 | False | None | None | False | None | False | 2159.82 | 0 | 3091950 | 106302 | None | code18 | Providing and fixing brass bib cock of approved quality 15 mmdia nominal bore(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 371.23 | 371.23 | 29.0 | False | None | None | False | None | False | 10765.67 | 0 | 3091951 | 106302 | None | code19 | Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 316.71 | 316.71 | 52.0 | False | None | None | False | None | False | 16468.92 | 0 | 3091952 | 106302 | None | code20 | Providing and fixing PVC (S.W.R) P Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 285.56 | 285.56 | 14.0 | False | None | None | False | None | False | 3997.84 | 0 | 3091953 | 106302 | None | code21 | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 7219.48 | 7219.48 | 6.0 | False | None | None | False | None | False | 43316.88 | 0 | 3091954 | 106302 | None | code22 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 362.14 | 362.14 | 6.0 | False | None | None | False | None | False | 2172.84 | 0 | 3091955 | 106302 | None | code23 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 644.04 | 644.04 | 6.0 | False | None | None | False | None | False | 3864.24 | 0 | 3091956 | 106302 | None | code24 | Providing and fixing Robe hook twin made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 711.3 | 711.3 | 27.0 | False | None | None | False | None | False | 19205.1 | 0 | 3091957 | 106302 | None | code25 | Providing and fixing Liquid soap dispenser made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 2266.31 | 2266.31 | 8.0 | False | None | None | False | None | False | 18130.48 | 0 | 3091958 | 106302 | None | code26 | Cutting holes up to 30x30 cm in walls including making good the same: With common burnt clay F.P.S. (non modular) bricks(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 419.25 | 419.25 | 18.0 | False | None | None | False | None | False | 7546.5 | 0 | 3091959 | 106302 | None | code27 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 406.27 | 406.27 | 18.0 | False | None | None | False | None | False | 7312.86 | 0 | 3091960 | 106302 | None | code28 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board-510x1040 mm bowl depth 178 mm(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 6271.94 | 6271.94 | 4.0 | False | None | None | False | None | False | 25087.76 | 0 | 3091961 | 106302 | None | code29 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board. Size: 610x510 mm bowl depth 200 mm(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 4705.25 | 4705.25 | 4.0 | False | None | None | False | None | False | 18821.0 | 0 | 3091962 | 106302 | None | code30 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 g(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 188.21 | 188.21 | 20.0 | False | None | None | False | None | False | 3764.2 | 0 | 3091963 | 106302 | None | code31 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 g.(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 253.11 | 253.11 | 2.0 | False | None | None | False | None | False | 506.22 | 0 | 3091964 | 106302 | None | code32 | Providing and fixing Angle cock with wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - For EWC, WB, Urinal, sink , Jonitor .Class - Economy(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 1403.14 | 1403.14 | 10.0 | False | None | None | False | None | False | 14031.4 | 0 | 3091965 | 106302 | None | code33 | Providing and fixing Bib cock with wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class - Economy(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 1449.87 | 1449.87 | 4.0 | False | None | None | False | None | False | 5799.48 | 0 | 3091966 | 106302 | None | code34 | Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3density Rock wool insulation with 22SWG Aluminium cladding. - 300 L Capacity(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 90841.83 | 90841.83 | 2.0 | False | None | None | False | None | False | 181683.66 | 0 | 3091967 | 106302 | None | code35 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipes(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | m | 401.08 | 401.08 | 85.0 | False | None | None | False | None | False | 34091.8 | 0 | 3091968 | 106302 | None | code36 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | m | 491.94 | 491.94 | 475.0 | False | None | None | False | None | False | 233671.5 | 0 | 3091969 | 106302 | None | code37 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipes(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | m | 619.15 | 619.15 | 215.0 | False | None | None | False | None | False | 133117.25 | 0 | 3091970 | 106302 | None | code38 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipes(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | m | 722.99 | 722.99 | 155.0 | False | None | None | False | None | False | 112063.45 | 0 | 3091971 | 106302 | None | code39 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 25mm DWS(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | m | 412.76 | 412.76 | 290.0 | False | None | None | False | None | False | 119700.4 | 0 | 3091972 | 106302 | None | code40 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32mm DWS(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | m | 519.2 | 519.2 | 335.0 | False | None | None | False | None | False | 173932.0 | 0 | 3091973 | 106302 | None | code41 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 40 mm nominal dia Pipes(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | m | 695.73 | 695.73 | 350.0 | False | None | None | False | None | False | 243505.5 | 0 | 3091974 | 106302 | None | code42 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 50 mm nominal dia Pipes(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | m | 1013.74 | 1013.74 | 268.0 | False | None | None | False | None | False | 271682.32 | 0 | 3091975 | 106302 | None | code43 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work Shafts & Terrace 15 mm nominal dia Pipes(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | m | 241.43 | 241.43 | 45.0 | False | None | None | False | None | False | 10864.35 | 0 | 3091976 | 106302 | None | code44 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work Shafts & Terrace 20 mm nominal dia Pipes(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | m | 482.86 | 482.86 | 120.0 | False | None | None | False | None | False | 57943.2 | 0 | 3091977 | 106302 | None | code45 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work Shafts & Terrace 25 mm nominal dia Pipes(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | m | 482.86 | 482.86 | 165.0 | False | None | None | False | None | False | 79671.9 | 0 | 3091978 | 106302 | None | code46 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work Shafts & Terrace 32 mm nominal dia Pipes(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | m | 482.86 | 482.86 | 425.0 | False | None | None | False | None | False | 205215.5 | 0 | 3091979 | 106302 | None | code47 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work Shafts & Terrace 40 mm nominal dia Pipes(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | m | 619.15 | 619.15 | 569.0 | False | None | None | False | None | False | 352296.35 | 0 | 3091980 | 106302 | None | code48 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work Shafts & Terrace 50 mm nominal dia Pipes(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | m | 935.86 | 935.86 | 660.0 | False | None | None | False | None | False | 617667.6 | 0 | 3091981 | 106302 | None | code49 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work Shafts & Terrace 65 mm nominal dia Pipes(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | m | 1817.2 | 1817.2 | 400.0 | False | None | None | False | None | False | 726880.0 | 0 | 3091982 | 106302 | None | code50 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work Shafts & Terrace 80 mm nominal dia pipes(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | m | 2327.31 | 2327.31 | 215.0 | False | None | None | False | None | False | 500371.65 | 0 | 3091983 | 106302 | None | code51 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work Shafts & Terrace 100 mm dia nomina; dia pipes(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | m | 3276.15 | 3276.15 | 235.0 | False | None | None | False | None | False | 769895.25 | 0 | 3091984 | 106302 | None | code52 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 883.94 | 883.94 | 54.0 | False | None | None | False | None | False | 47732.76 | 0 | 3091985 | 106302 | None | code53 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 712.6 | 712.6 | 47.0 | False | None | None | False | None | False | 33492.2 | 0 | 3091986 | 106302 | None | code54 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 32 mm nominal bore(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 771.01 | 771.01 | 39.0 | False | None | None | False | None | False | 30069.39 | 0 | 3091987 | 106302 | None | code55 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 40 mm nominal bore(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 911.2 | 911.2 | 36.0 | False | None | None | False | None | False | 32803.2 | 0 | 3091988 | 106302 | None | code56 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 50 mm nominal bore(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 1109.79 | 1109.79 | 29.0 | False | None | None | False | None | False | 32183.91 | 0 | 3091989 | 106302 | None | code57 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 65 mm nominal bore(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 1831.48 | 1831.48 | 21.0 | False | None | None | False | None | False | 38461.08 | 0 | 3091990 | 106302 | None | code58 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 80 mm nominal bore(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 2695.95 | 2695.95 | 14.0 | False | None | None | False | None | False | 37743.3 | 0 | 3091991 | 106302 | None | code59 | Supplying, installing, testing and commissioning of PN 16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc., complete. etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work 65mm dia CI butterfly valves(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 7139.0 | 7139.0 | 5.0 | False | None | None | False | None | False | 35695.0 | 0 | 3091992 | 106302 | None | code60 | Supplying, installing, testing and commissioning of PN 16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc., complete. etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work 50mm dia CI butterfly valves(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 5841.0 | 5841.0 | 5.0 | False | None | None | False | None | False | 29205.0 | 0 | 3091993 | 106302 | None | code61 | Supplying, installing, testing and commissioning of PN 16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc., complete. etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work 150mm dia CI butterfly valves(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 16225.0 | 16225.0 | 5.0 | False | None | None | False | None | False | 81125.0 | 0 | 3091994 | 106302 | None | code62 | Supplying, installing, testing and commissioning of PN 16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc., complete. etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work 100mm dia CI butterfly valves(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 11682.0 | 11682.0 | 8.0 | False | None | None | False | None | False | 93456.0 | 0 | 3091995 | 106302 | None | code63 | Supplying installing, testing and commissioning of PN 16 CI Non Return Valve confirming to IS 13039 with necessary bolts and nuts etc complete includes cost of all materials labour charges with all lead lift loading and unloading transportation etccomplete. etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for uccessful completion of work and as per directions of the Engineer-in-charge of the work 100 mm Dia CI Non Return Valve(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 9241.76 | 9241.76 | 3.0 | False | None | None | False | None | False | 27725.28 | 0 | 3091996 | 106302 | None | code64 | Supplying, installing, testing and commissioning of PN 16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc., complete. etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work 80 mm Dia CI Non Return Valve(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 7139.0 | 7139.0 | 8.0 | False | None | None | False | None | False | 57112.0 | 0 | 3091997 | 106302 | None | code65 | Supplying, installing, testing and commissioning of PN 16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc., complete. etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work 65 mm Dia CI Non Return Valve(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 5646.3 | 5646.3 | 12.0 | False | None | None | False | None | False | 67755.6 | 0 | 3091998 | 106302 | None | code66 | Supplying, installing, testing and commissioning of PN 16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc., complete. etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work 50 mm Dia CI Non Return Valve(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 3839.72 | 3839.72 | 12.0 | False | None | None | False | None | False | 46076.64 | 0 | 3091999 | 106302 | None | code67 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caustion lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m For Sewer allround In all kinds of soils. Depth upto 1.50m For Sewer allround For Rainwater allround For Ducts For water supply line from BW to building For Manhole Subsoil draiange works ( DNB & MCH)(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Cum | 628.23 | 628.23 | 864.0 | False | None | None | False | None | False | 542790.72 | 0 | 3092000 | 106302 | None | code68 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caustion lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.( Kitchen & Martury)(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Cum | 297.24 | 297.24 | 207.0 | False | None | None | False | None | False | 61528.68 | 0 | 3092001 | 106302 | None | code69 | Filling approved earth (excluding rock) in trenches, plinth, sides of
foundations and other similar works etc. in layers not exceeding 20cm
in depth, consolidating each deposited layer by ramming and watering,
lead up to 50 m and lift upto 1.5 m. ( DNB & MCH)(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Cum | 562.03 | 562.03 | 864.0 | False | None | None | False | None | False | 485593.92 | 0 | 3092002 | 106302 | None | code70 | Filling approved earth (excluding rock) in trenches, plinth, sides of
foundations and other similar works etc. in layers not exceeding 20cm
in depth, consolidating each deposited layer by ramming and watering,
lead up to 50 m and lift upto 1.5 m. (Kitchen & Martury)(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Cum | 297.24 | 297.24 | 207.0 | False | None | None | False | None | False | 61528.68 | 0 | 3092003 | 106302 | None | code71 | Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay (non modular) bricks of class designation 3.5(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 2214.39 | 2214.39 | 46.0 | False | None | None | False | None | False | 101861.94 | 0 | 3092004 | 106302 | None | code72 | Providing and fixing PVC (S.W.R) Gully Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 449.11 | 449.11 | 46.0 | False | None | None | False | None | False | 20659.06 | 0 | 3092005 | 106302 | None | code73 | Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover..(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 5498.33 | 5498.33 | 12.0 | False | None | None | False | None | False | 65979.96 | 0 | 3092006 | 106302 | None | code74 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(CATCH BASIN)(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 7079.29 | 7079.29 | 53.0 | False | None | None | False | None | False | 375202.37 | 0 | 3092007 | 106302 | None | code75 | Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover..(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 5498.33 | 5498.33 | 6.0 | False | None | None | False | None | False | 32989.98 | 0 | 3092008 | 106302 | None | code76 | Providing and constructing WIRE CUT BRICK MACHINEHOLE CHAMBERS using Portland/Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber. Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Providing and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Providing and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, de-watering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 1.0 M depth & SFRC cover & frame (BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 37703.01 | 37703.01 | 4.0 | False | None | None | False | None | False | 150812.04 | 0 | 3092009 | 106302 | None | code77 | Providing and constructing WIRE CUT BRICK MACHINEHOLE CHAMBERS using Portland/Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber. Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Providing and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Providing and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, de-watering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 1.2 M depth & SFRC cover & frame(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 40718.26 | 40718.26 | 5.0 | False | None | None | False | None | False | 203591.3 | 0 | 3092010 | 106302 | None | code78 | Providing and constructing WIRE CUT BRICK MACHINEHOLE CHAMBERS using Portland/Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber. Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Providing and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Providing and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, de-watering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 1.4 M depth & SFRC cover & frame(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 47422.43 | 47422.43 | 4.0 | False | None | None | False | None | False | 189689.72 | 0 | 3092011 | 106302 | None | code79 | Providing and constructing WIRE CUT BRICK MACHINEHOLE CHAMBERS using Portland/Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber. Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Providing and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Providing and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, de-watering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 1.6 M depth & SFRC cover & frame(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 53955.26 | 53955.26 | 3.0 | False | None | None | False | None | False | 161865.78 | 0 | 3092012 | 106302 | None | code80 | Providing and constructing WIRE CUT BRICK MACHINEHOLE CHAMBERS using Portland/Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber. Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Providing and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Providing and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, de-watering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 1.8 M depth & SFRC cover & frame(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 58264.62 | 58264.62 | 2.0 | False | None | None | False | None | False | 116529.24 | 0 | 3092013 | 106302 | None | code81 | Providing and constructing WIRE CUT BRICK MACHINEHOLE CHAMBERS using Portland/Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber. Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Providing and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Providing and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, de-watering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 2.0 M depth & SFRC cover & frame(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 78897.63 | 78897.63 | 1.0 | False | None | None | False | None | False | 78897.63 | 0 | 3092014 | 106302 | None | code82 | Supplying and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete . For DI/CI puddle flanges of 80mm dia.(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 2050.84 | 2050.84 | 18.0 | False | None | None | False | None | False | 36915.12 | 0 | 3092015 | 106302 | None | code83 | Supplying and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete . For DI/CI puddle flanges of For DI/CI puddle flanges of 100mm dia.(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 2415.58 | 2415.58 | 14.0 | False | None | None | False | None | False | 33818.12 | 0 | 3092016 | 106302 | None | code84 | Supplying and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete . For DI/CI puddle flanges of For DI/CI puddle flanges of 150mm dia.(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 3003.57 | 3003.57 | 8.0 | False | None | None | False | None | False | 24028.56 | 0 | 3092017 | 106302 | None | code85 | Supplying and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete . For DI/CI puddle flanges of For DI/CI puddle flanges of 200mm dia.(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 4051.06 | 4051.06 | 2.0 | False | None | None | False | None | False | 8102.12 | 0 | 3092018 | 106302 | None | code86 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 345.27 | 345.27 | 36.0 | False | None | None | False | None | False | 12429.72 | 0 | 3092019 | 106302 | None | code87 | Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with
jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete. for: - Sanitary works Pipes of SN8 Self Fit - 160mm dia.
(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | m | 800.87 | 800.87 | 320.0 | False | None | None | False | None | False | 256278.4 | 0 | 3092020 | 106302 | None | code88 | Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and
conveying to worksite, rolling and lowering into trenches, laying true to
line and level and perfect linking at joints, testing and commissioning,
including loading and unloading at both destinations and cuts of pipes
wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with
jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete. for: - Sanitary works Pipes of SN8 Self Fit - 200mm dia.(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | m | 1155.22 | 1155.22 | 260.0 | False | None | None | False | None | False | 300357.2 | 0 | 3092021 | 106302 | None | code89 | Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and
conveying to worksite, rolling and lowering into trenches, laying true to
line and level and perfect linking at joints, testing and commissioning,
including loading and unloading at both destinations and cuts of pipes
wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with
jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete. for: - Sanitary works Pipes of SN8 Self Fit - 250mm dia.(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | m | 1775.66 | 1775.66 | 85.0 | False | None | None | False | None | False | 150931.1 | 0 | 3092022 | 106302 | None | code90 | Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and
conveying to worksite, rolling and lowering into trenches, laying true to
line and level and perfect linking at joints, testing and commissioning,
including loading and unloading at both destinations and cuts of pipes
wherever necessary including jointing of UPVC pipes (with cost of elastomeric rubber rings) and specials (excluding cost of specials) with
jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for: Rain water works Pipes of SN4, 75mm dia.(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | m | 287.92 | 287.92 | 15.0 | False | None | None | False | None | False | 4318.8 | 0 | 3092023 | 106302 | None | code91 | Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and
conveying to worksite, rolling and lowering into trenches, laying true to
line and level and perfect linking at joints, testing and commissioning,
including loading and unloading at both destinations and cuts of pipes
wherever necessary including jointing of UPVC pipes (with cost of elastomeric rubber rings) and specials (excluding cost of specials) with
jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for: Rain water works Pipes of SN4, 110mm dia.(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | m | 373.82 | 373.82 | 25.0 | False | None | None | False | None | False | 9345.5 | 0 | 3092024 | 106302 | None | code92 | Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and
conveying to worksite, rolling and lowering into trenches, laying true to
line and level and perfect linking at joints, testing and commissioning,
including loading and unloading at both destinations and cuts of pipes
wherever necessary including jointing of UPVC pipes (with cost of elastomeric rubber rings) and specials (excluding cost of specials) with
jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for: Rain water works Pipes of SN4, 160mm dia.(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | m | 747.65 | 747.65 | 505.0 | False | None | None | False | None | False | 377563.25 | 0 | 3092025 | 106302 | None | code93 | Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric rubber rings) and specials (excluding cost of specials) with
jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for: Rain water works Pipes of SN4, 200mm dia.(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | m | 1078.64 | 1078.64 | 240.0 | False | None | None | False | None | False | 258873.6 | 0 | 3092026 | 106302 | None | code94 | Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and
conveying to worksite, rolling and lowering into trenches, laying true to
line and level and perfect linking at joints, testing and commissioning,
including loading and unloading at both destinations and cuts of pipes
wherever necessary including jointing of UPVC pipes (with cost of elastomeric rubber rings) and specials (excluding cost of specials) with
jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for: Rain water works Pipes of SN4, 250mm dia.(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | m | 1653.65 | 1653.65 | 155.0 | False | None | None | False | None | False | 256315.75 | 0 | 3092027 | 106302 | None | code95 | Construction of RCC Machinehole chambers of 1:1.5:3 proportion or
approved type Cast-insitu / Pre-cast RCC Machinehole chambers, constructed using form vibrators of standard type, with barricading, danger lighting and using of sight rails and boning rods wherever necessary, shoring and strutting wherever required using Ordinary Port Land Cement, using 1:1.5:3 proportion RCC with 20 mm and down graded jelly, well graded sand and steel of approved quality, 200 mm thick top concrete slab, having wall thickness and raft thickness as in approved drawings and with an offset in raft alround the chamber as in approved drawing, benching concrete with 1:6 slope towards the central drain finished smooth, including fixing and grouting of pipes, including conveying to work spot supply and fixing SFRC Machinehole cover and frame (Heavy duty) conforming to IS:12592 with latest amendments, on a bed of CC 1:2:4 supplying and fixing of minimum 3 mm thick encapsulated plastic footsteps (as per IS 10910) on 12 mm dia.
Grade Fe-500 steel bar (as per IS 1786) staggered at 300 mm apart as detailed in Technical specifications, including stone grit beding wherever required, watering, curing, engraving Machinehole number with flow direction on the inner cylindrical surface etc., complete including cost of reinforcement steel and fabrication charges and also cost and conveyance of all materials, labour with all lead and lifts. The Pre-cast RCC Machinehole are for various diamters and depths as stated below and as per detailed drawings, specifications and
direction of the Engineer. HDPE Manhole 1.2M dia 3m depth
(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 37642.0 | 37642.0 | 1.0 | False | None | None | False | None | False | 37642.0 | 0 | 3092028 | 106302 | None | code96 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 50 mm nominal bore, 206mm long, weighing not less than 690 g - 40mm dia(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 941.05 | 941.05 | 2.0 | False | None | None | False | None | False | 1882.1 | 0 | 3092029 | 106302 | None | code97 | Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments.(For neutralisation chamber-(1W+1S) and for existing UG sump- 1W) 2 HP, Size 65x50 Head 13M, Discharge 462 LPM (Martury)(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 20261.78 | 20261.78 | 2.0 | False | None | None | False | None | False | 40523.56 | 0 | 3092030 | 106302 | None | code98 | Water purification plants: Providing, Installation and Commissioning of automatic Water purification plant (RO+UF) with all accessories piping, product water tank on single phase power supply as per the enclosed detailed Technical Specifications including cost of material, loading and unloading and as directed by the Engineer in charge. (Ref- detailed specifications enclosed seperatly). Note:- 1.The above rates mentioned are only for the preparation of estimate purpose. 2. All items are to be of BSI / NFS standards,with BSI / NFS mark . 3. Tenders to be invited for procurement . 4. No direct payment should be made under any situation or condition or on any account. 5. After commissioning of plant necessary testing to be done for the satisfactory of Engineer Incharge. Note : Refer the
ANNEXURE : F for Detailed Specification of Each components (For 2000 LPH FRP : Skid Type) For MCH BLOCK(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 879524.8 | 879524.8 | 1.0 | False | None | None | False | None | False | 879524.8 | 0 | 3092031 | 106302 | None | code99 | Water purification plants: Providing, Installation and Commissioning of automatic Water purification plant (RO+UF) with all accessories piping, product water tank on single phase power supply as per the enclosed detailed Technical Specifications including cost of material, loading and unloading and as directed by the Engineer in charge. (Ref- detailed specifications enclosed seperatly). Note:- 1.The above rates mentioned are only for the preparation of estimate purpose. 2. All items are to be of BSI / NFS standards,with BSI / NFS mark . 3. Tenders to be invited for procurement . 4. No direct payment should be made under any situation or condition or on any account. 5. After commissioning of plant necessary testing to be done for the satisfactory of Engineer Incharge. Note : Refer the
ANNEXURE : F for Detailed Specification of Each components (For 500 LPH FRP : Skid Type) For DNB BLOCK(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 438334.6 | 438334.6 | 1.0 | False | None | None | False | None | False | 438334.6 | 0 | 3092032 | 106302 | None | code100 | Automatic Online Hydraulically Operated Self Cleaning Multi grade pressure Filter for the flow rate of ........................... LPH (............... M.L.D) with
16 hour pumping NOTE : For Detailed Specification of Automatic hydraulic self cleaning screen filter(400 Microns), FILTRATION & Filter Media For Pressure Filter, Anthracite, Carbon . Detailed Specification and Rates fot Separate components ( i.e.., Online Sensore, Filtration & Filder media) of 10000 LPH to 225000 LPH Refer Annexure-C (For 10000 & 15000 LPH (0.16 &0.24 M.L.D) For MCH & DNB BLOCK(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Set | 1260747.4 | 1260747.4 | 2.0 | False | None | None | False | None | False | 2521494.8 | 0 | 3092033 | 106302 | None | code101 | PUMPS: Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. (Domestic water pumps from sump OHT)(10HP, size 80x65 Head 34.5M, Discharge 840 LPM)(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 48834.65 | 48834.65 | 2.0 | False | None | None | False | None | False | 97669.3 | 0 | 3092034 | 106302 | None | code102 | Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. (Domestic water pumps from sump OHT) (7.5HP, size 65x50 Head 46.0M, Discharge 360 LPM)(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 50187.17 | 50187.17 | 4.0 | False | None | None | False | None | False | 200748.68 | 0 | 3092035 | 106302 | None | code103 | Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. (Domestic water pumps from sump OHT) (5.0HP, size 50x40 Head 46.0M, Discharge 174 LPM)(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 37718.19 | 37718.19 | 2.0 | False | None | None | False | None | False | 75436.38 | 0 | 3092036 | 106302 | None | code104 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work.(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Job | 8437.0 | 8437.0 | 8.0 | False | None | None | False | None | False | 67496.0 | 0 | 3092037 | 106302 | None | code105 | CO2 2Kg Squeeze grip
Providing 2 Kg C02 Gas Type Fire Extinugisher Squeeze grip type, used Unused Mechanism, Squeeze Grip, Gross Weight 9.1 Kg. empty Weight 7.1 Kg. Can Height 595MM Diameter 108MM, Discharge Time less than 8 Sees, Controllable discharge
mechanism, Applicable on Class 8&C Fire, 8 Rating 88, Can Construction : Hot spinning/Forging, Valve Construction : Forging & Machining, Internal Coating of Can : Not Applicable, External coating of Can : Spray Painting, Sheet metal thickness: 4.0MM lSI Approved, 1 Year Warranty.with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 5321.8 | 5321.8 | 1.0 | False | None | None | False | None | False | 5321.8 | 0 | 3092038 | 106302 | None | code106 | CO2 2Kg Squeeze grip
Providing 2 Kg C02 Gas Type Fire Extinugisher Squeeze grip type, used Unused Mechanism, Squeeze Grip, Gross Weight 9.1 Kg. empty Weight 7.1 Kg. Can Height 595MM Diameter 108MM, Discharge Time less than 8 Sees, Controllable discharge
mechanism, Applicable on Class 8&C Fire, 8 Rating 88, Can Construction : Hot spinning/Forging, Valve Construction : Forging & Machining, Internal Coating of Can : Not Applicable, External coating of Can : Spray Painting, Sheet metal thickness: 4.0MM lSI Approved, 1 Year Warranty.with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 9735.0 | 9735.0 | 1.0 | False | None | None | False | None | False | 9735.0 | 0 | 3092039 | 106302 | None | code107 | SEWAGE LIFTING PUMPS Supplying, installing, testing and commissioning approved make Submersible Pump made of C.I Construction suitable for building application. Thequoted rate shall also include for auto lvl.controller with cabling between hePumps, control panel, UGR & OHT etc.,. complete.approx. Length of cable = 80. providing necessary safety devices viz. dry run protection, over load relays etc., complete working on 230V, 50Hz, 1Ph, with starter,.(1 no. working and 1no. Standby) Sump To OHT (Sewage lifting pumps) Duty : 5 lps @ 25m head (1 no. working and 1no. Standby ) MAKE: CRI / KIRLOSKAR(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 76700.0 | 76700.0 | 2.0 | False | None | None | False | None | False | 153400.0 | 0 | 3092040 | 106302 | None | code108 | Supply of Grease separator made of polyethylene as per DIN EN 1825; proven Stability of 50 years; for below ground installation; overall dia of 1320 mm. with ventilation provision; emptying via suction line DN 65 PN 10; counter flange with fire hose quick coupling 75B and 2 1/2 blank cap and satisfy reaction to fire Class A .
Standard odour tight top cover of 600 mm dia. clear opening; frame made of concrete material and cover made of cast iron; with raising tube, load class A15 according to EN 124
Inlet and outlet dia: DN 150
Make: ACO: Model: Lipumax PD
Nominal Size: NS 7
Grease Storage: 285L, Sludge Storage: 730L, Overall Capacity: 1675L
Art No: 3207.81.00 + 3300.14.01(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 407100.0 | 407100.0 | 1.0 | False | None | None | False | None | False | 407100.0 | 0 | 3092041 | 106302 | None | code109 | HYDROPNEUMATIC SYSTEM Supply, erection, testing and commissioning of multi VFD pump variable speed Hydro system comprising of vertical multistage type fitted with standard motor impeller and other vital parts of the pump made in SS 304, high quality control panel comprising of change over dry run protection, DOL Starter, suction and discharge, manifolds, isolation valves, non-return valves, Y' strainer, pressure gauges, non-metallic pressure vessel all skid mounted etc., complete. a. Vertical, In-Line, Multisage, centrifugal pumps with SS-304 casing and impeller and SS-316 shaft, CI base & head TEFC motor (with mechanical seal) (Vendor to submit performance curves and technical catalog of the proposed model for review & information) The pump shall be selected for performance at best efficiency point. However, the pump selection shall be suitable for performance with set point @ + 20% of the rated head. b. External Pump mounted or wall mounted microprocessor PID controller and frequency inverter integrated in a single body or as separate components with pressure sensor transmitter minimum two lined LCD display, diodes to indicate pump ready, pump running and fault and capable to communicate with other controllers following MODBUS-RTU or BACNET Class-2 protocall through RS485 port. System should be capable to compensate for frictional losses at lower flows. All alarms should be displayed in the controller. System should be equiped with dry running protection - Quantity : 1 No. c. Complete (Skid mounted wall mounted / floor mounted) electrical control panel comprising of all accessories such as PLCs, pressure switches, pressure transducers, control wiring and any other necessary imports etc. (list to be provided by the vendor)d. Precharged diaphram pressure vessel with food grade membrane, charging connection, connected to outlet header with necessary flanges, gaskets, isolating valves, nuts/bolts etc complete. e. Set of accessories such as pressure switches, pressure transducers, inter connecting power and control cabling etc. complete f. Accessories like pressure gauge, MS base frame (Synthetic enamel painted over a coat of primer) g. GI suction and delivery header with flanges for inlet connection, common outlet header with flanges for outlet connections as required, and inter connecting piping with flexible connections, eccentric type reducers etc. all necessary indigenous accessories as required to complete the installation. Note: Contractor to note that the suction header is required to have inlet connection from the Puddle Flange @ water tanks and to the pump suction. Provision of delivery header is required to have outlet connection from the pumps. Suitable outlet flanges from the delivery mainfold / header shall be provided as required. MAKE: Grundfos Type: Vertical Multistage Flow rate: 5LPS Two pump system: (1 Workimng + 1 Standby) Power supply: 3Pha 50 Hz. Impellor : SS , IE 3 Cut in: 2.5 Bar Cutoff : 3.5 Bar(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Set | 1711000.0 | 1711000.0 | 1.0 | False | None | None | False | None | False | 1711000.0 | 0 | 3092042 | 106302 | None | code110 | HOT WATER SYSTEM -10,000 Litres per day - AIR TO WATER HEAT PUMP Design, Engineering, Supply and commissioning of Hot water system and Pumps as specified below. Drawings shall be submitted for approval as per site condition. Hot water temperature - 60 C Cold water INLET temperature - 25 C Rated output heating capacity - 20.34 kw Delta T 35 C ( Rise in temperature) The Heat Pump shall have the following specifications : Out put rate 1000 Ltrs / hr at 35 deg delta T Heat pump Model: As per manufacturer design / standard Heating Capacity: 17500 Kilo Calorie for each Heat Pump Noise level: 60 dB Compressor : Hermetically Sealed Scroll Compressor Unit Evaporator / cold side heat exchanger Condenser / hot side heat exchanger Flow regulation valve as required, Check valve as required Temperature Gauge - as required with Visual indication Necessary Internal controls Rated output heating capacity - 20.34kw Input power consumption-6.75 kW Input power supply - 400V/3Ph/50Hz Water connection - Inlet and outlet dia - 40 mm dia Inlet water temperature - 25 deg C Outlet water temperature - 60 deg C Minimum Co-efficient of performance - 3.5 Environmental frendly and CFC free refrigerant viz.,: R407C, R410A, RA17A & R134A Approved Make: Emerson 2NOS = (1WORKING+ 1 STD By ) - Emergency all the the four can work(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Nos | 531000.0 | 531000.0 | 2.0 | False | None | None | False | None | False | 1062000.0 | 0 | 3092043 | 106302 | None | code111 | Circulation Pumps (For Heat Pumps) Supply, Testing and commissioning of approved make circulation pumps for Hot water circulation between the Heat pump and the Mixing Tank. The pumps shall be horizontal multistage type and coupled with suitable TEFC motor of following duty points.
Discharge: 6 cum/hr @ 15 meters head.
Make : Grundfos/ wilo /xylem ( Set = 2working + 1 std by ) (BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Set | 188800.0 | 188800.0 | 2.0 | False | None | None | False | None | False | 377600.0 | 0 | 3092044 | 106302 | None | code112 | Centralised Control Panel for hot water circulation pumps (Heat pump) Supply, Testing and commissioning of Electrical panel board for Integration and automatic operation of 3 nos of circulation pumps. The panel shall have separate switch gear for two pumps able to alternate beween working Pump and Stand by Pump for consecutive cycles. The panel shall have dry run protection, over load relay & phase preventor with auto manual operation. (Individual panel for each heat pump)
Make: Aproved sample(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Nos | 62304.0 | 62304.0 | 2.0 | False | None | None | False | None | False | 124608.0 | 0 | 3092045 | 106302 | None | code113 | Mixing Tank Interconnecting , installation, testing and commissoning, of fabricated MS tank floor supported horizontal type 5000 litres storage capacity hot water mixing tanks. The tank shall have internally protected with 3mmm thick FRP lining. The tank shall be suitable for a minimum working pressure of 8 kg / sq.cm and a test pressure of 12 kg / sq.cm. The tank shall be fabricated out of 8mm thick MS plate and dish end shall be 8mmm thick. The tank shall be insulated with 100 mm thick PUF / Rockwool insulation having a density of 48 kg / cu.m with best thermal characteristics and lowest heat loss covered with chicken wire mesh including 26 gauge aluminium cladding. The inside portion of the tank shall be finished with two coats of spary galvanising of 100 microns. Tank shall include 450mm dia manhole, inlet and outlet pipe connections, drain pipe and level indicators, 1nos Pressure gauges, 1nos temperature gauge at inlet and outlet side, flow meter etc. including structural supports for mounting on concrete pedestal. Thermal sensor ports, port for thermometer, ARV, PRV, Pressure guage with needle valve, Temperature guage with needle valve Approved Make: Approved sample(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Nos | 501500.0 | 501500.0 | 1.0 | False | None | None | False | None | False | 501500.0 | 0 | 3092046 | 106302 | None | code114 | Hot Water Return Recirculation pump with Timer Panel Supply, testing and commissioning of hot water recirculation pump (From Hot water network) capacity of as mentioned below including electrical panel board for integration and automatic operation of return hot water circulation pump with necessary timer. etc complete.
Make : Grundfos pump with Panel Duty of pump : 2 cum/hr @ 20 m Head (Set= 1Pump+ 1panel )(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Set | 147500.0 | 147500.0 | 2.0 | False | None | None | False | None | False | 295000.0 | 0 | 3092047 | 106302 | None | code115 | Supply installation, 300mm wide cable tray for running cables from elecytrical control pnael to heat pumps. The scope including neceessary termination of cables.(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Rmtr | 590.0 | 590.0 | 90.0 | False | None | None | False | None | False | 53100.0 | 0 | 3092048 | 106302 | None | code116 | HOT WATER SYSTEM -6,000 Litres per day - AIR TO WATER HEAT PUMP Design, Engineering, Supply and commissioning of Hot water system and Pumps as specified below. Drawings shall be submitted for approval as per site condition. Hot water temperature - 60 C Cold water INLET temperature - 25 C Rated output heating capacity - 17.00kw Delta T 35 C ( Rise in temperature) The Heat Pump shall have the following specifications : Out put rate 500 Ltrs / hr at 35 deg delta T Heat pump Model: As per manufacturer design / standard Heating Capacity: 43750 Kilo Calorie for each Heat Pump Noise level: 60 dB Compressor : Hermetically Sealed Scroll Compressor Unit Evaporator / cold side heat exchanger Condenser / hot side heat exchanger Flow regulation valve as required, Check valve as required Temperature Gauge - as required with Visual indication Necessary Internal controls Rated output heating capacity - 17.00kw Input power consumption-5.0kW Input power supply - 400V/3Ph/50Hz Water connection - Inlet and outlet dia - 40 mm dia Inlet water temperature - 25 deg C Outlet water temperature - 60 deg C Minimum Co-efficient of performance - 3.5 Environmental frendly and CFC free refrigerant viz.,: R407C, R410A, RA17A & R134A Approved Make: Emerson 2NOS = (1WORKING+ 1 STD By ) - Emergency both can work(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Nos | 265500.0 | 265500.0 | 2.0 | False | None | None | False | None | False | 531000.0 | 0 | 3092049 | 106302 | None | code117 | Circulation Pumps (For Heat Pumps) Supply, Testing and commissioning of approved make circulation pumps for Hot water circulation between the Heat pump and the Mixing Tank. The pumps shall be horizontal multistage type and coupled with suitable TEFC motor of following duty points.
Discharge: 3.8 cum/hr @ 15 meters head.
Make : Grundfos/ wilo /xylem ( Set = 1working + 1 std by ) (BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Set | 53100.0 | 53100.0 | 2.0 | False | None | None | False | None | False | 106200.0 | 0 | 3092050 | 106302 | None | code118 | Mixing Tank Interconnecting , installation, testing and commissoning, of fabricated MS tank floor supported horizontal type 2500 litres storage capacity hot water mixing tanks. The tank shall have internally protected with 3mmm thick FRP lining. The tank shall be suitable for a minimum working pressure of 8 kg / sq.cm and a test pressure of 12 kg / sq.cm. The tank shall be fabricated out of 8mm thick MS plate and dish end shall be 8mmm thick. The tank shall be insulated with 100 mm thick PUF / Rockwool insulation having a density of 48 kg / cu.m with best thermal characteristics and lowest heat loss covered with chicken wire mesh including 26 gauge aluminium cladding. The inside portion of the tank shall be finished with two coats of spary galvanising of 100 microns. Tank shall include 450mm dia manhole, inlet and outlet pipe connections, drain pipe and level indicators, 1nos Pressure gauges, 1nos temperature gauge at inlet and outlet side, flow meter etc. including structural supports for mounting on concrete pedestal. Thermal sensor ports, port for thermometer, ARV, PRV, Pressure guage with needle valve, Temperature guage with needle valve Approved Make: Approved sample(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Nos | 295000.0 | 295000.0 | 1.0 | False | None | None | False | None | False | 295000.0 | 0 | 3092051 | 106302 | None | code119 | Providing, fixing, testing and commissioning of Air Vent Cowel 110mm(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Nos | 219.48 | 219.48 | 20.0 | False | None | None | False | None | False | 4389.6 | 0 | 3092052 | 106302 | None | code120 | Providing, fixing, testing and commissioning of Air Vent Cowel 75mm(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Nos | 189.98 | 189.98 | 28.0 | False | None | None | False | None | False | 5319.44 | 0 | 3092053 | 106302 | None | code121 | Drilling holes of 2.50 cms dia (roof/chajja/stone). -do- in slabs upto 7.50 cms thick(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Nos | 154.58 | 154.58 | 20.0 | False | None | None | False | None | False | 3091.6 | 0 | 3092054 | 106302 | None | code122 | Drilling holes of 2.50 cms dia (roof/chajja/stone). -do- in slabs upto 10 cms thick(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Nos | 185.26 | 185.26 | 20.0 | False | None | None | False | None | False | 3705.2 | 0 | 3092055 | 106302 | None | code123 | Supplying and fixing PCC Pedestal 450 x 250 x 200mm with MS sloted angle iron brackets, supports with necessary drilling holes to suit the insertion of pipe clamps deburning etc., as per detailed drawing for supporting water supply pipes with suitable MS clamps, bolts, anchor bolts, nuts and washers fixed on shaft walls / outer walls etc. The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 0.08mm thick confoMed to IS 1239 etc., complete as directed by the employer.(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Nos | 767.0 | 767.0 | 20.0 | False | None | None | False | None | False | 15340.0 | 0 | 3092056 | 106302 | None | code124 | Supplying and fixing Counter basin consisting of size: 420 x 590 x 195, Shape: oval of ISI or BIS Standards with a single 15mm C.P. 32mm dia CP waste coupling, 32mmdia heavy duty CP bottle trap. CP pillar cock with extension pipe, CP wall flanges, 1 Nos.15mm dia C.P. angle cocks, 2nos.C.P. flexible inlet connection pipes, CI brackets etc., complete including silicon sealant filling. (Jaguar make or Equalent )(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Nos | 9318.46 | 9318.46 | 116.0 | False | None | None | False | None | False | 1080941.36 | 0 | 3092057 | 106302 | None | code125 | Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. (Jaguar make or Equalent)(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Nos | 2558.24 | 2558.24 | 157.0 | False | None | None | False | None | False | 401643.68 | 0 | 3092058 | 106302 | None | code126 | Providing and fixing floor trap grating with accessories etc,. Complete.(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 177.0 | 177.0 | 5.0 | False | None | None | False | None | False | 885.0 | 0 | 3092059 | 106302 | None | code127 | Supplying, fixing, testing and commissioning of Sink Cock with Swinging Casted Spout (Wall Mounted Model): CON-CHR-347KN for pantry sink with CP wall flange etc. Standard make confirming to ISI standards,Model as per attached photo catalogue and as per instruction of engineer incharge. ( Jaguar make or Equalent )(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 1996.56 | 1996.56 | 6.0 | False | None | None | False | None | False | 11979.36 | 0 | 3092060 | 106302 | None | code128 | Providing and fixing in position Exposed Part Kit of Concealed Stop Cock with Fitting Sleeve, Operating Lever & Adjustable Wall Flange (Compatible with ALD-087FT) ( Jaguar make or Equalent ) including cost of all materials, labour and HOM of equipments with all leads complete as per specifications..(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 1147.9 | 1147.9 | 2.0 | False | None | None | False | None | False | 2295.8 | 0 | 3092061 | 106302 | None | code129 | Supplying, fixing, testing and commissioning of Sink Cock with Eco Elbow Action Pillar Cock Bib Tap Faucet (Deck Mount Installation Type)(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 2478.0 | 2478.0 | 4.0 | False | None | None | False | None | False | 9912.0 | 0 | 3092062 | 106302 | None | code130 | Supply and fixing of SS 304 trough drain as per the kitchen consultant design. The supply of floor drain shall be done by the kitchen consultant. The fixing and piping for drain will be done by the plumbing consultant. Approx sizes shall be 1200mm x300mm x300mm(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 17700.0 | 17700.0 | 8.0 | False | None | None | False | None | False | 141600.0 | 0 | 3092063 | 106302 | None | code131 | Supply and fixing of SS 034 tough drain as per the kitchen consultant design. The supply of floor drain shall be done by the kitchen consultant. The fixing and piping for drain will be done by the plumbing consultant. Approx sizes shall be 900mm x300mm x300mm(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 14160.0 | 14160.0 | 6.0 | False | None | None | False | None | False | 84960.0 | 0 | 3092064 | 106302 | None | code132 | Supply and fixing of SS 304 trough drain as per the kitchen consultant design. The supply of floor drain shall be done by the kitchen consultant. The fixing and piping for drain will be done by the plumbing consultant. Approx sizes shall be 600mm x300mm x300mm(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 10620.0 | 10620.0 | 6.0 | False | None | None | False | None | False | 63720.0 | 0 | 3092065 | 106302 | None | code133 | Supplying, installing, testing and commissioning approved make Submersible Pump made of C.I Construction suitable for building application. Thequoted rate shall also include for auto lvl.controller with cabling between hePumps, control panel, UGR & OHT etc.,. complete.approx. Length of cable = 80. Providing necessary safety devices viz. dry run protection, over load relays etc., complete working on 230V, 50Hz, 1Ph, with starter,.(1 no. working and 1no. Standby) (Sub soil drain water lifting pumps) Duty : 5 lps @ 25m head (1 no. working and 1no. Standby ) MAKE: CRI / KIRLOSKAR(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Nos | 76700.0 | 76700.0 | 4.0 | False | None | None | False | None | False | 306800.0 | 0 | 3092066 | 106302 | None | code134 | Supplying, installing, testing and commissioning approved make Submersible Pump made of C.I Construction suitable for building application. Thequoted rate shall also include for auto lvl.controller with cabling between hePumps, control panel, UGR & OHT etc.,. complete.approx. Length of cable = 80. Providing necessary safety devices viz. dry run protection, over load relays etc., complete working on 230V, 50Hz, 1Ph, with starter,.(1 no. working and 1no. Standby) (Basement & Pump room dewatering pumps) Duty : 5 lps @ 15m head (1 no. working and 1no. Standby ) MAKE: CRI / KIRLOSKAR(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Nos | 64900.0 | 64900.0 | 6.0 | False | None | None | False | None | False | 389400.0 | 0 | 3092067 | 106302 | None | code135 | SUB SOIL DRAINAGE WORKS Supply, fixing and testing of Semi perforated PVC pipes conforming to IS 13592-1992 type -B, class-3 of 6kg/sqcm pressure with solvent cement joint, inclusive of all necessary copling etc, complete laid under floor as per detailed darwing. 160mm dia(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 1416.0 | 1416.0 | 550.0 | False | None | None | False | None | False | 778800.0 | 0 | 3092068 | 106302 | None | code136 | Providing and laying M sand layer in the trenches for full width of the trench as shown in the drawing.(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Unit | 1888.0 | 1888.0 | 120.0 | False | None | None | False | None | False | 226560.0 | 0 | 3092069 | 106302 | None | code137 | Providing and laying 12mm size grade agrregate for subsoil drainage system to the specified width and depeth as indicated in the drawing. Cost shall include necessary lead lifts etc, complete.(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Cum | 1180.0 | 1180.0 | 140.0 | False | None | None | False | None | False | 165200.0 | 0 | 3092070 | 106302 | None | code138 | Providing and laying 20mm size grade agrregate for subsoil drainage system to the specified width and depeth as indicated in the drawing. Cost shall include necessary lead lifts etc, complete.(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Cum | 1416.0 | 1416.0 | 120.0 | False | None | None | False | None | False | 169920.0 | 0 | 3092071 | 106302 | None | code139 | Providing and wrapping polypropylene non woven geo filter fabric of 1.8mm thick around the drainage pipe as indicated in the drawing for smooth draiange system without any clogging.(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Sqm | 236.0 | 236.0 | 750.0 | False | None | None | False | None | False | 177000.0 | 0 | 3092072 | 106302 | None | code140 | Supply and installation of GI puddle flanges. 32mm dia (BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 944.0 | 944.0 | 8.0 | False | None | None | False | None | False | 7552.0 | 0 | 3092073 | 106302 | None | code141 | Supply and installation of GI puddle flanges. 40mm dia(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 1180.0 | 1180.0 | 8.0 | False | None | None | False | None | False | 9440.0 | 0 | 3092074 | 106302 | None | code142 | Supply and installation of GI puddle flanges. 50mm dia(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 1888.0 | 1888.0 | 16.0 | False | None | None | False | None | False | 30208.0 | 0 | 3092075 | 106302 | None | code143 | Supply and installation of GI puddle flanges. 65mm dia(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 2360.0 | 2360.0 | 12.0 | False | None | None | False | None | False | 28320.0 | 0 | 3092076 | 106302 | None | code144 | Construction of stormwater Recharge pit of size 1.2m dia clear x 5.0m depth using precast concrete rungs with perforations at regular intervals. Bottom 600mm depth of pit shall be filled with coarse sand and the balance up to the invert of the Recharge pit inlet shall be filled with brick bats of 40mm and below size. The top of the Recharge pit shall be covered with RCC slab of suitable thickness with RCC 1:2:4 with 600 x 600mm RCC manhole frame cover. PCC bed of 1:3:6 100mm thick shall be provided for the Recharge pit walls. Earthwork excavation for Recharge pit in all types of soil and backfilling with suitable earth, including interconnecting RCC hume pipes from storm water drain to recharge pit. etc., complete. The scope of work included with drilling 160mm dia bore ho;e upto a depth of 20m. borewell providing perforated pipe and geotextile wrapping etc, complete. (BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 53100.0 | 53100.0 | 12.0 | False | None | None | False | None | False | 637200.0 | 0 | 3092077 | 106302 | None | code145 | Providing & fixing of insulation for exposed hot water CPVC hot water pipes with VIDOFLEX 9 mm preformed tubings wrapped all round. All joints shall be sealed with POLYBOND V (adhesive, followed by application of self adhesive, black cotton tape PCS 2250, on both longitudinal & circumferenacial joints to give uniform apperance and finish, including cladding with heavy gauge aluminium sheet and rivetting the same. 20 mmdia(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 206.5 | 206.5 | 560.0 | False | None | None | False | None | False | 115640.0 | 0 | 3092078 | 106302 | None | code146 | Providing & fixing of insulation for exposed hot water CPVC hot water pipes with VIDOFLEX 9 mm preformed tubings wrapped all round. All joints shall be sealed with POLYBOND V (adhesive, followed by application of self adhesive, black cotton tape PCS 2250, on both longitudinal & circumferenacial joints to give uniform apperance and finish, including cladding with heavy gauge aluminium sheet and rivetting the same. 25 mm dia(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 236.0 | 236.0 | 430.0 | False | None | None | False | None | False | 101480.0 | 0 | 3092079 | 106302 | None | code147 | Providing & fixing of insulation for exposed hot water CPVC hot water pipes with VIDOFLEX 9 mm preformed tubings wrapped all round. All joints shall be sealed with POLYBOND V (adhesive, followed by application of self adhesive, black cotton tape PCS 2250, on both longitudinal & circumferenacial joints to give uniform apperance and finish, including cladding with heavy gauge aluminium sheet and rivetting the same. 32 mm dia(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 265.5 | 265.5 | 260.0 | False | None | None | False | None | False | 69030.0 | 0 | 3092080 | 106302 | None | code148 | Providing & fixing of insulation for exposed hot water CPVC hot water pipes with VIDOFLEX 9 mm preformed tubings wrapped all round. All joints shall be sealed with POLYBOND V (adhesive, followed by application of self adhesive, black cotton tape PCS 2250, on both longitudinal & circumferenacial joints to give uniform apperance and finish, including cladding with heavy gauge aluminium sheet and rivetting the same. 40 mm dia(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 295.0 | 295.0 | 225.0 | False | None | None | False | None | False | 66375.0 | 0 | 3092081 | 106302 | None | code149 | Providing & fixing of insulation for exposed hot water CPVC hot water pipes with VIDOFLEX 9 mm preformed tubings wrapped all round. All joints shall be sealed with POLYBOND V (adhesive, followed by application of self adhesive, black cotton tape PCS 2250, on both longitudinal & circumferenacial joints to give uniform apperance and finish, including cladding with heavy gauge aluminium sheet and rivetting the same. 50 mm dia(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 354.0 | 354.0 | 100.0 | False | None | None | False | None | False | 35400.0 | 0 | 3092082 | 106302 | None | code150 | Supply and instalation of GI Class C puddle flanges 32 mm dia(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 944.0 | 944.0 | 12.0 | False | None | None | False | None | False | 11328.0 | 0 | 3092083 | 106302 | None | code151 | Supply and instalation of GI Class C puddle flanges 40mm dia(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 1770.0 | 1770.0 | 12.0 | False | None | None | False | None | False | 21240.0 | 0 | 3092084 | 106302 | None | code152 | Supply and instalation of GI Class C puddle flanges 50mm dia(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 2360.0 | 2360.0 | 24.0 | False | None | None | False | None | False | 56640.0 | 0 | 3092085 | 106302 | None | code153 | Supply and instalation of GI Class C puddle flanges 65 mm dia(BASEMENT + GROUND FLOOR + EXTERNAL WORK WATER SUPPLY) ---- etc., complete with all lead | Each | 2950.0 | 2950.0 | 12.0 | False | None | None | False | None | False | 35400.0 | 0 | 3092086 | 106302 | None | code154 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittingsThis includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40mm dia pipes, From wash basin waste lines(FIRST FLOOR WATER SUPPLY) ---- etc., complete with all lead | m | 398.53 | 398.53 | 220.0 | False | None | None | False | None | False | 87676.6 | 0 | 3092087 | 106302 | None | code155 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittingsThis includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50mm dia pipes, From sink & urinal waste lines(FIRST FLOOR WATER SUPPLY) ---- etc., complete with all lead | m | 506.04 | 506.04 | 110.0 | False | None | None | False | None | False | 55664.4 | 0 | 3092088 | 106302 | None | code156 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 75mm nominal dia pipes (FIRST FLOOR WATER SUPPLY) ---- etc., complete with all lead | m | 378.87 | 378.87 | 25.0 | False | None | None | False | None | False | 9471.75 | 0 | 3092089 | 106302 | None | code157 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 110mm nominal dia pipes (FIRST FLOOR WATER SUPPLY) ---- etc., complete with all lead | m | 504.73 | 504.73 | 50.0 | False | None | None | False | None | False | 25236.5 | 0 | 3092090 | 106302 | None | code158 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.(FIRST FLOOR WATER SUPPLY) ---- etc., complete with all lead | Each | 1599.4 | 1599.4 | 55.0 | False | None | None | False | None | False | 87967.0 | 0 | 3092091 | 106302 | None | code159 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931(FIRST FLOOR WATER SUPPLY) ---- etc., complete with all lead | Each | 812.81 | 812.81 | 104.0 | False | None | None | False | None | False | 84532.24 | 0 | 3092092 | 106302 | None | code160 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid(FIRST FLOOR WATER SUPPLY) ---- etc., complete with all lead | Each | 6342.52 | 6342.52 | 34.0 | False | None | None | False | None | False | 215645.68 | 0 | 3092093 | 106302 | None | code161 | Providing and fixing CP brass toilet paper holder(FIRST FLOOR WATER SUPPLY) ---- etc., complete with all lead | Each | 797.08 | 797.08 | 34.0 | False | None | None | False | None | False | 27100.72 | 0 | 3092094 | 106302 | None | code162 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: One urinal basin with 5 litre white P.V.C. automatic flushing cistern(FIRST FLOOR WATER SUPPLY) ---- etc., complete with all lead | Each | 5839.1 | 5839.1 | 8.0 | False | None | None | False | None | False | 46712.8 | 0 | 3092095 | 106302 | None | code163 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.(FIRST FLOOR WATER SUPPLY) ---- etc., complete with all lead | Nos | 950.46 | 950.46 | 44.0 | False | None | None | False | None | False | 41820.24 | 0 | 3092096 | 106302 | None | code164 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps(FIRST FLOOR WATER SUPPLY) ---- etc., complete with all lead | Each | 4040.44 | 4040.44 | 41.0 | False | None | None | False | None | False | 165658.04 | 0 | 3092097 | 106302 | None | code165 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge.(FIRST FLOOR WATER SUPPLY) ---- etc., complete with all lead | Each | 1061.89 | 1061.89 | 53.0 | False | None | None | False | None | False | 56280.17 | 0 | 3092098 | 106302 | None | code166 | Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore)(FIRST FLOOR WATER SUPPLY) ---- etc., complete with all lead | Each | 108.81 | 108.81 | 106.0 | False | None | None | False | None | False | 11533.86 | 0 | 3092099 | 106302 | None | code167 | Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g(FIRST FLOOR WATER SUPPLY) ---- etc., complete with all lead | Each | 401.16 | 401.16 | 51.0 | False | None | None | False | None | False | 20459.16 | 0 | 3092100 | 106302 | None | code168 | Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 15 mm nominal bore, weighing not less than 32 g (FIRST FLOOR WATER SUPPLY) ---- etc., complete with all lead | Nos | 83.9 | 83.9 | 44.0 | False | None | None | False | None | False | 3691.6 | 0 | 3092101 | 106302 | None | code169 | Providing and fixing brass bib cock of approved quality 15 mm nominal bore(FIRST FLOOR WATER SUPPLY) ---- etc., complete with all lead | Nos | 374.94 | 374.94 | 33.0 | False | None | None | False | None | False | 12373.02 | 0 | 3092102 | 106302 | None | code170 | Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0
cm X 4.0 cm with all fitting arrangements & all necessary accessories
complete(FIRST FLOOR WATER SUPPLY) ---- etc., complete with all lead | Each | 319.88 | 319.88 | 60.0 | False | None | None | False | None | False | 19192.8 | 0 | 3092103 | 106302 | None | code171 | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.(FIRST FLOOR WATER SUPPLY) ---- etc., complete with all lead | Each | 7291.67 | 7291.67 | 10.0 | False | None | None | False | None | False | 72916.7 | 0 | 3092104 | 106302 | None | code172 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :(FIRST FLOOR WATER SUPPLY) ---- etc., complete with all lead | Each | 365.76 | 365.76 | 10.0 | False | None | None | False | None | False | 3657.6 | 0 | 3092105 | 106302 | None | code173 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.(FIRST FLOOR WATER SUPPLY) ---- etc., complete with all lead | Each | 650.25 | 650.25 | 10.0 | False | None | None | False | None | False | 6502.5 | 0 | 3092106 | 106302 | None | code174 | Providing and fixing Robe hook twin made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy(FIRST FLOOR WATER SUPPLY) ---- etc., complete with all lead | Each | 718.42 | 718.42 | 21.0 | False | None | None | False | None | False | 15086.82 | 0 | 3092107 | 106302 | None | code175 | Providing and fixing Liquid soap dispenser made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy(FIRST FLOOR WATER SUPPLY) ---- etc., complete with all lead | Each | 2288.97 | 2288.97 | 6.0 | False | None | None | False | None | False | 13733.82 | 0 | 3092108 | 106302 | None | code176 | Cutting holes up to 30x30 cm in walls including making good the same: With common burnt clay F.P.S. (non modular) bricks(FIRST FLOOR WATER SUPPLY) ---- etc., complete with all lead | Each | 423.45 | 423.45 | 26.0 | False | None | None | False | None | False | 11009.7 | 0 | 3092109 | 106302 | None | code177 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size), including finishing complete so as to
make it leak proof.(FIRST FLOOR WATER SUPPLY) ---- etc., complete with all lead | Each | 410.34 | 410.34 | 26.0 | False | None | None | False | None | False | 10668.84 | 0 | 3092110 | 106302 | None | code178 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board-510x1040 mm bowl depth 178 mm(FIRST FLOOR WATER SUPPLY) ---- etc., complete with all lead | Each | 6334.66 | 6334.66 | 3.0 | False | None | None | False | None | False | 19003.98 | 0 | 3092111 | 106302 | None | code179 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required: Size 600x450x200 mm(FIRST FLOOR WATER SUPPLY) ---- etc., complete with all lead | Each | 6659.78 | 6659.78 | 10.0 | False | None | None | False | None | False | 66597.8 | 0 | 3092112 | 106302 | None | code180 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15mm nominal dia Pipes(FIRST FLOOR WATER SUPPLY) ---- etc., complete with all lead | m | 405.09 | 405.09 | 90.0 | False | None | None | False | None | False | 36458.1 | 0 | 3092113 | 106302 | None | code181 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes(FIRST FLOOR WATER SUPPLY) ---- etc., complete with all lead | m | 496.86 | 496.86 | 560.0 | False | None | None | False | None | False | 278241.6 | 0 | 3092114 | 106302 | None | code182 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipes(FIRST FLOOR WATER SUPPLY) ---- etc., complete with all lead | m | 625.34 | 625.34 | 345.0 | False | None | None | False | None | False | 215742.3 | 0 | 3092115 | 106302 | None | code183 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipes(FIRST FLOOR WATER SUPPLY) ---- etc., complete with all lead | m | 730.22 | 730.22 | 300.0 | False | None | None | False | None | False | 219066.0 | 0 | 3092116 | 106302 | None | code184 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 25mm DWS(FIRST FLOOR WATER SUPPLY) ---- etc., complete with all lead | m | 416.89 | 416.89 | 205.0 | False | None | None | False | None | False | 85462.45 | 0 | 3092117 | 106302 | None | code185 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 32mm DWS(FIRST FLOOR WATER SUPPLY) ---- etc., complete with all lead | m | 524.39 | 524.39 | 235.0 | False | None | None | False | None | False | 123231.65 | 0 | 3092118 | 106302 | None | code186 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 40 mm nominal dia Pipes(FIRST FLOOR WATER SUPPLY) ---- etc., complete with all lead | m | 702.69 | 702.69 | 215.0 | False | None | None | False | None | False | 151078.35 | 0 | 3092119 | 106302 | None | code187 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 50 mm nominal dia Pipes(FIRST FLOOR WATER SUPPLY) ---- etc., complete with all lead | m | 1023.88 | 1023.88 | 190.0 | False | None | None | False | None | False | 194537.2 | 0 | 3092120 | 106302 | None | code188 | Providing and placingon terrace (at all floor levels) polyethylene water storage tank IS-12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipe but witout fittings and the base support for tank.(FIRST FLOOR WATER SUPPLY) ---- etc., complete with all lead | Ltr | 10.49 | 10.49 | 5000.0 | False | None | None | False | None | False | 52450.0 | 0 | 3092121 | 106302 | None | code189 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solventcement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40mm dia pipes, From wash basin waste lines(SECOND FLOOR) ---- etc., complete with all lead | m | 402.48 | 402.48 | 230.0 | False | None | None | False | None | False | 92570.4 | 0 | 3092122 | 106302 | None | code190 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solventcement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50mm dia pipes, From sink & urinal waste lines(SECOND FLOOR) ---- etc., complete with all lead | m | 511.05 | 511.05 | 90.0 | False | None | None | False | None | False | 45994.5 | 0 | 3092123 | 106302 | None | code191 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 75mm nominal dia pipes (SECOND FLOOR) ---- etc., complete with all lead | m | 382.62 | 382.62 | 490.0 | False | None | None | False | None | False | 187483.8 | 0 | 3092124 | 106302 | None | code192 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 110mm nominal dia pipes (SECOND FLOOR) ---- etc., complete with all lead | m | 509.72 | 509.72 | 450.0 | False | None | None | False | None | False | 229374.0 | 0 | 3092125 | 106302 | None | code193 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.(SECOND FLOOR) ---- etc., complete with all lead | Each | 1615.23 | 1615.23 | 35.0 | False | None | None | False | None | False | 56533.05 | 0 | 3092126 | 106302 | None | code194 | Providing and fixing C.P. brass angle valve for basin mixer and geyser
points of approved quality conforming to IS:8931(SECOND FLOOR) ---- etc., complete with all lead | Each | 820.86 | 820.86 | 82.0 | False | None | None | False | None | False | 67310.52 | 0 | 3092127 | 106302 | None | code195 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid(SECOND FLOOR) ---- etc., complete with all lead | Each | 6405.32 | 6405.32 | 24.0 | False | None | None | False | None | False | 153727.68 | 0 | 3092128 | 106302 | None | code196 | Providing and fixing CP brass toilet paper holder(SECOND FLOOR) ---- etc., complete with all lead | Each | 804.97 | 804.97 | 24.0 | False | None | None | False | None | False | 19319.28 | 0 | 3092129 | 106302 | None | code197 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: One urinal basin with 5 litre white P.V.C. automatic flushing cistern(SECOND FLOOR) ---- etc., complete with all lead | Each | 5896.92 | 5896.92 | 9.0 | False | None | None | False | None | False | 53072.28 | 0 | 3092130 | 106302 | None | code198 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.(SECOND FLOOR) ---- etc., complete with all lead | Each | 959.87 | 959.87 | 36.0 | False | None | None | False | None | False | 34555.32 | 0 | 3092131 | 106302 | None | code199 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps(SECOND FLOOR) ---- etc., complete with all lead | Each | 4080.44 | 4080.44 | 17.0 | False | None | None | False | None | False | 69367.48 | 0 | 3092132 | 106302 | None | code200 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge.(SECOND FLOOR) ---- etc., complete with all lead | Each | 1072.41 | 1072.41 | 41.0 | False | None | None | False | None | False | 43968.81 | 0 | 3092133 | 106302 | None | code201 | Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore)(SECOND FLOOR) ---- etc., complete with all lead | Each | 109.89 | 109.89 | 82.0 | False | None | None | False | None | False | 9010.98 | 0 | 3092134 | 106302 | None | code202 | Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g(SECOND FLOOR) ---- etc., complete with all lead | Each | 405.13 | 405.13 | 41.0 | False | None | None | False | None | False | 16610.33 | 0 | 3092135 | 106302 | None | code203 | Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 15 mm nominal bore, weighing not less than 32 g (SECOND FLOOR) ---- etc., complete with all lead | Each | 84.73 | 84.73 | 24.0 | False | None | None | False | None | False | 2033.52 | 0 | 3092136 | 106302 | None | code204 | Providing and fixing brass bib cock of approved quality 15 mm nominal bore(SECOND FLOOR) ---- etc., complete with all lead | Each | 378.65 | 378.65 | 16.0 | False | None | None | False | None | False | 6058.4 | 0 | 3092137 | 106302 | None | code205 | Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm x 7.5 cm x 5.0 cm x4.0 cm with all fitting arrangements & all necessary accessories complete(SECOND FLOOR) ---- etc., complete with all lead | Each | 323.05 | 323.05 | 50.0 | False | None | None | False | None | False | 16152.5 | 0 | 3092138 | 106302 | None | code206 | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.(SECOND FLOOR) ---- etc., complete with all lead | Each | 7363.87 | 7363.87 | 6.0 | False | None | None | False | None | False | 44183.22 | 0 | 3092139 | 106302 | None | code207 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :(SECOND FLOOR) ---- etc., complete with all lead | Each | 369.38 | 369.38 | 6.0 | False | None | None | False | None | False | 2216.28 | 0 | 3092140 | 106302 | None | code208 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.(SECOND FLOOR) ---- etc., complete with all lead | Each | 656.68 | 656.68 | 6.0 | False | None | None | False | None | False | 3940.08 | 0 | 3092141 | 106302 | None | code209 | Providing and fixing Robe hook twin made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy(SECOND FLOOR) ---- etc., complete with all lead | Each | 725.53 | 725.53 | 20.0 | False | None | None | False | None | False | 14510.6 | 0 | 3092142 | 106302 | None | code210 | Providing and fixing Liquid soap dispenser made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy(SECOND FLOOR) ---- etc., complete with all lead | Each | 2311.63 | 2311.63 | 6.0 | False | None | None | False | None | False | 13869.78 | 0 | 3092143 | 106302 | None | code211 | Cutting holes up to 30x30 cm in walls including making good the same: With common burnt clay F.P.S. (non modular) bricks(SECOND FLOOR) ---- etc., complete with all lead | Each | 427.64 | 427.64 | 26.0 | False | None | None | False | None | False | 11118.64 | 0 | 3092144 | 106302 | None | code212 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size), including finishing complete so as to
make it leak proof.(SECOND FLOOR) ---- etc., complete with all lead | Each | 414.4 | 414.4 | 26.0 | False | None | None | False | None | False | 10774.4 | 0 | 3092145 | 106302 | None | code213 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board-510x1040 mm bowl depth 178 mm(SECOND FLOOR) ---- etc., complete with all lead | Each | 6397.37 | 6397.37 | 4.0 | False | None | None | False | None | False | 25589.48 | 0 | 3092146 | 106302 | None | code214 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipes(SECOND FLOOR) ---- etc., complete with all lead | m | 409.1 | 409.1 | 90.0 | False | None | None | False | None | False | 36819.0 | 0 | 3092147 | 106302 | None | code215 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc 20 mm nominal dia Pipes(SECOND FLOOR) ---- etc., complete with all lead | m | 501.78 | 501.78 | 510.0 | False | None | None | False | None | False | 255907.8 | 0 | 3092148 | 106302 | None | code216 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc 25 mm nominal dia pipes(SECOND FLOOR) ---- etc., complete with all lead | m | 631.53 | 631.53 | 270.0 | False | None | None | False | None | False | 170513.1 | 0 | 3092149 | 106302 | None | code217 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc 32 mm nominal dia pipes(SECOND FLOOR) ---- etc., complete with all lead | m | 737.45 | 737.45 | 200.0 | False | None | None | False | None | False | 147490.0 | 0 | 3092150 | 106302 | None | code218 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 25mm pipes(SECOND FLOOR) ---- etc., complete with all lead | m | 421.02 | 421.02 | 200.0 | False | None | None | False | None | False | 84204.0 | 0 | 3092151 | 106302 | None | code219 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 32mm pipes(SECOND FLOOR) ---- etc., complete with all lead | m | 529.58 | 529.58 | 170.0 | False | None | None | False | None | False | 90028.6 | 0 | 3092152 | 106302 | None | code220 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 40 mm nominal dia Pipes(SECOND FLOOR) ---- etc., complete with all lead | m | 709.64 | 709.64 | 115.0 | False | None | None | False | None | False | 81608.6 | 0 | 3092153 | 106302 | None | code221 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 50 mm nominal dia Pipes(SECOND FLOOR) ---- etc., complete with all lead | m | 1034.01 | 1034.01 | 120.0 | False | None | None | False | None | False | 124081.2 | 0 | 3092154 | 106302 | None | code222 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40mm dia pipes, From wash basin waste lines(THIRD FLOOR) ---- etc., complete with all lead | m | 406.43 | 406.43 | 220.0 | False | None | None | False | None | False | 89414.6 | 0 | 3092155 | 106302 | None | code223 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50mm dia pipes, From sink & urinal waste lines(THIRD FLOOR) ---- etc., complete with all lead | m | 516.06 | 516.06 | 95.0 | False | None | None | False | None | False | 49025.7 | 0 | 3092156 | 106302 | None | code224 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 75mm nominal dia pipes (THIRD FLOOR) ---- etc., complete with all lead | m | 386.38 | 386.38 | 500.0 | False | None | None | False | None | False | 193190.0 | 0 | 3092157 | 106302 | None | code225 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipes (THIRD FLOOR) ---- etc., complete with all lead | m | 514.72 | 514.72 | 470.0 | False | None | None | False | None | False | 241918.4 | 0 | 3092158 | 106302 | None | code226 | Providing and fixing 600x450 mm beveled edge mirror of superior glass(of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (THIRD FLOOR) ---- etc., complete with all lead | Each | 1631.07 | 1631.07 | 36.0 | False | None | None | False | None | False | 58718.52 | 0 | 3092159 | 106302 | None | code227 | Providing and fixing C.P. brass angle valve for basin mixer and geyser
points of approved quality conforming to IS:8931(THIRD FLOOR) ---- etc., complete with all lead | Each | 828.9 | 828.9 | 84.0 | False | None | None | False | None | False | 69627.6 | 0 | 3092160 | 106302 | None | code228 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid(THIRD FLOOR) ---- etc., complete with all lead | Each | 6468.12 | 6468.12 | 23.0 | False | None | None | False | None | False | 148766.76 | 0 | 3092161 | 106302 | None | code229 | Providing and fixing CP brass toilet paper holder(THIRD FLOOR) ---- etc., complete with all lead | Each | 812.86 | 812.86 | 23.0 | False | None | None | False | None | False | 18695.78 | 0 | 3092162 | 106302 | None | code230 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: One urinal basin with 5 litre white P.V.C. automatic flushing cistern(THIRD FLOOR) ---- etc., complete with all lead | Each | 5954.73 | 5954.73 | 8.0 | False | None | None | False | None | False | 47637.84 | 0 | 3092163 | 106302 | None | code231 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.(THIRD FLOOR) ---- etc., complete with all lead | Each | 969.28 | 969.28 | 36.0 | False | None | None | False | None | False | 34894.08 | 0 | 3092164 | 106302 | None | code232 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps(THIRD FLOOR) ---- etc., complete with all lead | Each | 4120.45 | 4120.45 | 18.0 | False | None | None | False | None | False | 74168.1 | 0 | 3092165 | 106302 | None | code233 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge.(THIRD FLOOR) ---- etc., complete with all lead | Each | 1082.92 | 1082.92 | 42.0 | False | None | None | False | None | False | 45482.64 | 0 | 3092166 | 106302 | None | code234 | Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore)(THIRD FLOOR) ---- etc., complete with all lead | Each | 110.97 | 110.97 | 82.0 | False | None | None | False | None | False | 9099.54 | 0 | 3092167 | 106302 | None | code235 | Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g(THIRD FLOOR) ---- etc., complete with all lead | Each | 409.1 | 409.1 | 42.0 | False | None | None | False | None | False | 17182.2 | 0 | 3092168 | 106302 | None | code236 | Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 15 mm nominal bore, weighing not less than 32 g (THIRD FLOOR) ---- etc., complete with all lead | Each | 85.56 | 85.56 | 23.0 | False | None | None | False | None | False | 1967.88 | 0 | 3092169 | 106302 | None | code237 | Providing and fixing brass bib cock of approved quality 15 mm nominal bore(THIRD FLOOR) ---- etc., complete with all lead | Each | 382.36 | 382.36 | 16.0 | False | None | None | False | None | False | 6117.76 | 0 | 3092170 | 106302 | None | code238 | Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm x 7.5 cm x 5.0 cm x4.0 cm with all fitting arrangements & all necessary accessories complete(THIRD FLOOR) ---- etc., complete with all lead | Each | 326.21 | 326.21 | 50.0 | False | None | None | False | None | False | 16310.5 | 0 | 3092171 | 106302 | None | code239 | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.(THIRD FLOOR) ---- etc., complete with all lead | Each | 7436.06 | 7436.06 | 13.0 | False | None | None | False | None | False | 96668.78 | 0 | 3092172 | 106302 | None | code240 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :(THIRD FLOOR) ---- etc., complete with all lead | Each | 373.01 | 373.01 | 13.0 | False | None | None | False | None | False | 4849.13 | 0 | 3092173 | 106302 | None | code241 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.(THIRD FLOOR) ---- etc., complete with all lead | Each | 663.12 | 663.12 | 13.0 | False | None | None | False | None | False | 8620.56 | 0 | 3092174 | 106302 | None | code242 | Providing and fixing Robe hook twin made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy(THIRD FLOOR) ---- etc., complete with all lead | Each | 732.64 | 732.64 | 23.0 | False | None | None | False | None | False | 16850.72 | 0 | 3092175 | 106302 | None | code243 | Providing and fixing Liquid soap dispenser made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy(THIRD FLOOR) ---- etc., complete with all lead | Each | 2334.3 | 2334.3 | 8.0 | False | None | None | False | None | False | 18674.4 | 0 | 3092176 | 106302 | None | code244 | Cutting holes up to 30x30 cm in walls including making good the same: With common burnt clay F.P.S. (non modular) bricks(THIRD FLOOR) ---- etc., complete with all lead | Each | 431.83 | 431.83 | 18.0 | False | None | None | False | None | False | 7772.94 | 0 | 3092177 | 106302 | None | code245 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size), including finishing complete so as to
make it leak proof.(THIRD FLOOR) ---- etc., complete with all lead | Each | 418.46 | 418.46 | 18.0 | False | None | None | False | None | False | 7532.28 | 0 | 3092178 | 106302 | None | code246 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board-510x1040 mm bowl depth 178 mm(THIRD FLOOR) ---- etc., complete with all lead | Each | 6460.09 | 6460.09 | 3.0 | False | None | None | False | None | False | 19380.27 | 0 | 3092179 | 106302 | None | code247 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc 15 mm nominal dia Pipes.(THIRD FLOOR) ---- etc., complete with all lead | m | 413.11 | 413.11 | 90.0 | False | None | None | False | None | False | 37179.9 | 0 | 3092180 | 106302 | None | code248 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc 20 mm nominal dia Pipes(THIRD FLOOR) ---- etc., complete with all lead | m | 506.7 | 506.7 | 510.0 | False | None | None | False | None | False | 258417.0 | 0 | 3092181 | 106302 | None | code249 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc 25 mm nominal dia pipes(THIRD FLOOR) ---- etc., complete with all lead | m | 637.72 | 637.72 | 270.0 | False | None | None | False | None | False | 172184.4 | 0 | 3092182 | 106302 | None | code250 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc 32 mm nominal dia pipes(THIRD FLOOR) ---- etc., complete with all lead | m | 744.68 | 744.68 | 200.0 | False | None | None | False | None | False | 148936.0 | 0 | 3092183 | 106302 | None | code251 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 25mm DWS(THIRD FLOOR) ---- etc., complete with all lead | m | 425.15 | 425.15 | 200.0 | False | None | None | False | None | False | 85030.0 | 0 | 3092184 | 106302 | None | code252 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 32mm DWS(THIRD FLOOR) ---- etc., complete with all lead | m | 534.78 | 534.78 | 170.0 | False | None | None | False | None | False | 90912.6 | 0 | 3092185 | 106302 | None | code253 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 40 mm nominal dia Pipes(THIRD FLOOR) ---- etc., complete with all lead | m | 716.6 | 716.6 | 110.0 | False | None | None | False | None | False | 78826.0 | 0 | 3092186 | 106302 | None | code254 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 50 mm nominal dia Pipes(THIRD FLOOR) ---- etc., complete with all lead | m | 1044.15 | 1044.15 | 90.0 | False | None | None | False | None | False | 93973.5 | 0 | 3092187 | 106302 | None | code255 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40mm dia pipes, From wash basin waste lines(FOURTH FLOOR) ---- etc., complete with all lead | m | 410.38 | 410.38 | 240.0 | False | None | None | False | None | False | 98491.2 | 0 | 3092188 | 106302 | None | code256 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50mm dia pipes, From sink & urinal waste lines(FOURTH FLOOR) ---- etc., complete with all lead | m | 521.07 | 521.07 | 110.0 | False | None | None | False | None | False | 57317.7 | 0 | 3092189 | 106302 | None | code257 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 75mm nominal dia pipes (FOURTH FLOOR) ---- etc., complete with all lead | m | 390.13 | 390.13 | 605.0 | False | None | None | False | None | False | 236028.65 | 0 | 3092190 | 106302 | None | code258 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 110mm nominal dia pipes (FOURTH FLOOR) ---- etc., complete with all lead | m | 519.72 | 519.72 | 500.0 | False | None | None | False | None | False | 259860.0 | 0 | 3092191 | 106302 | None | code259 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.(FOURTH FLOOR) ---- etc., complete with all lead | Each | 1646.9 | 1646.9 | 45.0 | False | None | None | False | None | False | 74110.5 | 0 | 3092192 | 106302 | None | code260 | Providing and fixing C.P. brass angle valve for basin mixer and geyser
points of approved quality conforming to IS:8931(FOURTH FLOOR) ---- etc., complete with all lead | Each | 836.95 | 836.95 | 90.0 | False | None | None | False | None | False | 75325.5 | 0 | 3092193 | 106302 | None | code261 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid(FOURTH FLOOR) ---- etc., complete with all lead | Each | 6530.91 | 6530.91 | 33.0 | False | None | None | False | None | False | 215520.03 | 0 | 3092194 | 106302 | None | code262 | Providing and fixing CP brass toilet paper holder(FOURTH FLOOR) ---- etc., complete with all lead | Each | 820.75 | 820.75 | 33.0 | False | None | None | False | None | False | 27084.75 | 0 | 3092195 | 106302 | None | code263 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: One urinal basin with 5 litre white P.V.C. automatic flushing cistern(FOURTH FLOOR) ---- etc., complete with all lead | Each | 6012.54 | 6012.54 | 4.0 | False | None | None | False | None | False | 24050.16 | 0 | 3092196 | 106302 | None | code264 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.(FOURTH FLOOR) ---- etc., complete with all lead | Each | 978.69 | 978.69 | 52.0 | False | None | None | False | None | False | 50891.88 | 0 | 3092197 | 106302 | None | code265 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps(FOURTH FLOOR) ---- etc., complete with all lead | Each | 4160.45 | 4160.45 | 28.0 | False | None | None | False | None | False | 116492.6 | 0 | 3092198 | 106302 | None | code266 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge.(FOURTH FLOOR) ---- etc., complete with all lead | Each | 1093.44 | 1093.44 | 45.0 | False | None | None | False | None | False | 49204.8 | 0 | 3092199 | 106302 | None | code267 | Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore)(FOURTH FLOOR) ---- etc., complete with all lead | Each | 112.04 | 112.04 | 90.0 | False | None | None | False | None | False | 10083.6 | 0 | 3092200 | 106302 | None | code268 | Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g(FOURTH FLOOR) ---- etc., complete with all lead | Each | 413.08 | 413.08 | 45.0 | False | None | None | False | None | False | 18588.6 | 0 | 3092201 | 106302 | None | code269 | Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 15 mm nominal bore, weighing not less than 32 g (FOURTH FLOOR) ---- etc., complete with all lead | Each | 86.39 | 86.39 | 33.0 | False | None | None | False | None | False | 2850.87 | 0 | 3092202 | 106302 | None | code270 | Providing and fixing brass bib cock of approved quality 15 mm nominal bore(FOURTH FLOOR) ---- etc., complete with all lead | Each | 386.08 | 386.08 | 20.0 | False | None | None | False | None | False | 7721.6 | 0 | 3092203 | 106302 | None | code271 | Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm x 7.5 cm x 5.0 cm x 4.0 cm with all fitting arrangements & all necessary accessories complete(FOURTH FLOOR) ---- etc., complete with all lead | Each | 329.38 | 329.38 | 74.0 | False | None | None | False | None | False | 24374.12 | 0 | 3092204 | 106302 | None | code272 | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.(FOURTH FLOOR) ---- etc., complete with all lead | Each | 7508.26 | 7508.26 | 30.0 | False | None | None | False | None | False | 225247.8 | 0 | 3092205 | 106302 | None | code273 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :(FOURTH FLOOR) ---- etc., complete with all lead | Each | 376.63 | 376.63 | 30.0 | False | None | None | False | None | False | 11298.9 | 0 | 3092206 | 106302 | None | code274 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.(FOURTH FLOOR) ---- etc., complete with all lead | Each | 669.56 | 669.56 | 30.0 | False | None | None | False | None | False | 20086.8 | 0 | 3092207 | 106302 | None | code275 | Providing and fixing Robe hook twin made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy(FOURTH FLOOR) ---- etc., complete with all lead | Each | 739.76 | 739.76 | 33.0 | False | None | None | False | None | False | 24412.08 | 0 | 3092208 | 106302 | None | code276 | Providing and fixing Liquid soap dispenser made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy(FOURTH FLOOR) ---- etc., complete with all lead | Each | 2356.96 | 2356.96 | 6.0 | False | None | None | False | None | False | 14141.76 | 0 | 3092209 | 106302 | None | code277 | Cutting holes up to 30x30 cm in walls including making good the same: With common burnt clay F.P.S. (non modular) bricks(FOURTH FLOOR) ---- etc., complete with all lead | Each | 436.02 | 436.02 | 18.0 | False | None | None | False | None | False | 7848.36 | 0 | 3092210 | 106302 | None | code278 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size), including finishing complete so as to
make it leak proof.(FOURTH FLOOR) ---- etc., complete with all lead | Each | 422.52 | 422.52 | 18.0 | False | None | None | False | None | False | 7605.36 | 0 | 3092211 | 106302 | None | code279 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board-510x1040 mm bowl depth 178 mm(FOURTH FLOOR) ---- etc., complete with all lead | Each | 6522.81 | 6522.81 | 7.0 | False | None | None | False | None | False | 45659.67 | 0 | 3092212 | 106302 | None | code280 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipes(FOURTH FLOOR) ---- etc., complete with all lead | m | 417.13 | 417.13 | 100.0 | False | None | None | False | None | False | 41713.0 | 0 | 3092213 | 106302 | None | code281 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes(FOURTH FLOOR) ---- etc., complete with all lead | m | 511.62 | 511.62 | 750.0 | False | None | None | False | None | False | 383715.0 | 0 | 3092214 | 106302 | None | code282 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipes(FOURTH FLOOR) ---- etc., complete with all lead | m | 643.91 | 643.91 | 350.0 | False | None | None | False | None | False | 225368.5 | 0 | 3092215 | 106302 | None | code283 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipes(FOURTH FLOOR) ---- etc., complete with all lead | m | 751.91 | 751.91 | 230.0 | False | None | None | False | None | False | 172939.3 | 0 | 3092216 | 106302 | None | code284 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 25mm DWS(FOURTH FLOOR) ---- etc., complete with all lead | m | 429.27 | 429.27 | 190.0 | False | None | None | False | None | False | 81561.3 | 0 | 3092217 | 106302 | None | code285 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 32mm DWS(FOURTH FLOOR) ---- etc., complete with all lead | m | 539.97 | 539.97 | 250.0 | False | None | None | False | None | False | 134992.5 | 0 | 3092218 | 106302 | None | code286 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 40 mm nominal dia Pipes(FOURTH FLOOR) ---- etc., complete with all lead | m | 723.56 | 723.56 | 190.0 | False | None | None | False | None | False | 137476.4 | 0 | 3092219 | 106302 | None | code287 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 50 mm nominal dia Pipes(FOURTH FLOOR) ---- etc., complete with all lead | m | 1054.29 | 1054.29 | 60.0 | False | None | None | False | None | False | 63257.4 | 0 | 3092220 | 106302 | None | code288 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40mm dia pipes, From wash basin waste lines(FIFTH FLOOR) ---- etc., complete with all lead | m | 414.32 | 414.32 | 180.0 | False | None | None | False | None | False | 74577.6 | 0 | 3092221 | 106302 | None | code289 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50mm dia pipes, From sink & urinal waste lines(FIFTH FLOOR) ---- etc., complete with all lead | m | 526.08 | 526.08 | 70.0 | False | None | None | False | None | False | 36825.6 | 0 | 3092222 | 106302 | None | code290 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 75mm nominal dia pipes (FIFTH FLOOR) ---- etc., complete with all lead | m | 393.88 | 393.88 | 480.0 | False | None | None | False | None | False | 189062.4 | 0 | 3092223 | 106302 | None | code291 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 110mm nominal dia pipes (FIFTH FLOOR) ---- etc., complete with all lead | m | 524.72 | 524.72 | 420.0 | False | None | None | False | None | False | 220382.4 | 0 | 3092224 | 106302 | None | code292 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (FIFTH FLOOR) ---- etc., complete with all lead | Each | 1662.74 | 1662.74 | 39.0 | False | None | None | False | None | False | 64846.86 | 0 | 3092225 | 106302 | None | code293 | Providing and fixing C.P. brass angle valve for basin mixer and geyser
points of approved quality conforming to IS:8931(FIFTH FLOOR) ---- etc., complete with all lead | Each | 845.0 | 845.0 | 78.0 | False | None | None | False | None | False | 65910.0 | 0 | 3092226 | 106302 | None | code294 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid(FIFTH FLOOR) ---- etc., complete with all lead | Each | 6593.71 | 6593.71 | 26.0 | False | None | None | False | None | False | 171436.46 | 0 | 3092227 | 106302 | None | code295 | Providing and fixing CP brass toilet paper holder(FIFTH FLOOR) ---- etc., complete with all lead | Each | 828.64 | 828.64 | 26.0 | False | None | None | False | None | False | 21544.64 | 0 | 3092228 | 106302 | None | code296 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: One urinal basin with 5 litre white P.V.C. automatic flushing cistern(FIFTH FLOOR) ---- etc., complete with all lead | Each | 6070.36 | 6070.36 | 4.0 | False | None | None | False | None | False | 24281.44 | 0 | 3092229 | 106302 | None | code297 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.(FIFTH FLOOR) ---- etc., complete with all lead | Each | 988.1 | 988.1 | 52.0 | False | None | None | False | None | False | 51381.2 | 0 | 3092230 | 106302 | None | code298 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps(FIFTH FLOOR) ---- etc., complete with all lead | Each | 4200.46 | 4200.46 | 31.0 | False | None | None | False | None | False | 130214.26 | 0 | 3092231 | 106302 | None | code299 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm(FIFTH FLOOR) ---- etc., complete with all lead | Each | 6926.26 | 6926.26 | 2.0 | False | None | None | False | None | False | 13852.52 | 0 | 3092232 | 106302 | None | code300 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge.(FIFTH FLOOR) ---- etc., complete with all lead | Each | 1103.95 | 1103.95 | 39.0 | False | None | None | False | None | False | 43054.05 | 0 | 3092233 | 106302 | None | code301 | Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore)(FIFTH FLOOR) ---- etc., complete with all lead | Each | 113.12 | 113.12 | 78.0 | False | None | None | False | None | False | 8823.36 | 0 | 3092234 | 106302 | None | code302 | Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g(FIFTH FLOOR) ---- etc., complete with all lead | Each | 417.05 | 417.05 | 39.0 | False | None | None | False | None | False | 16264.95 | 0 | 3092235 | 106302 | None | code303 | Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 15 mm nominal bore, weighing not less than 32 g (FIFTH FLOOR) ---- etc., complete with all lead | Each | 87.23 | 87.23 | 26.0 | False | None | None | False | None | False | 2267.98 | 0 | 3092236 | 106302 | None | code304 | Providing and fixing brass bib cock of approved quality 15 mm nominal bore(FIFTH FLOOR) ---- etc., complete with all lead | Each | 389.79 | 389.79 | 20.0 | False | None | None | False | None | False | 7795.8 | 0 | 3092237 | 106302 | None | code305 | Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm x7.5 cm x 5.0 cm x4.0 cm with all fitting arrangements & all necessary accessories complete(FIFTH FLOOR) ---- etc., complete with all lead | Each | 332.55 | 332.55 | 54.0 | False | None | None | False | None | False | 17957.7 | 0 | 3092238 | 106302 | None | code306 | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.(FIFTH FLOOR) ---- etc., complete with all lead | Each | 7580.45 | 7580.45 | 15.0 | False | None | None | False | None | False | 113706.75 | 0 | 3092239 | 106302 | None | code307 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :(FIFTH FLOOR) ---- etc., complete with all lead | Each | 380.25 | 380.25 | 15.0 | False | None | None | False | None | False | 5703.75 | 0 | 3092240 | 106302 | None | code308 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.(FIFTH FLOOR) ---- etc., complete with all lead | Each | 676.0 | 676.0 | 15.0 | False | None | None | False | None | False | 10140.0 | 0 | 3092241 | 106302 | None | code309 | Providing and fixing Robe hook twin made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy(FIFTH FLOOR) ---- etc., complete with all lead | Each | 746.87 | 746.87 | 26.0 | False | None | None | False | None | False | 19418.62 | 0 | 3092242 | 106302 | None | code310 | Providing and fixing Liquid soap dispenser made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy(FIFTH FLOOR) ---- etc., complete with all lead | Each | 2379.62 | 2379.62 | 6.0 | False | None | None | False | None | False | 14277.72 | 0 | 3092243 | 106302 | None | code311 | Cutting holes up to 30x30 cm in walls including making good the same: With common burnt clay F.P.S. (non modular) bricks(FIFTH FLOOR) ---- etc., complete with all lead | Each | 440.22 | 440.22 | 26.0 | False | None | None | False | None | False | 11445.72 | 0 | 3092244 | 106302 | None | code312 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size), including finishing complete so as to
make it leak proof.(FIFTH FLOOR) ---- etc., complete with all lead | Each | 426.59 | 426.59 | 26.0 | False | None | None | False | None | False | 11091.34 | 0 | 3092245 | 106302 | None | code313 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board-510x1040 mm bowl depth 178 mm(FIFTH FLOOR) ---- etc., complete with all lead | Each | 6585.53 | 6585.53 | 1.0 | False | None | None | False | None | False | 6585.53 | 0 | 3092246 | 106302 | None | code314 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipes(FIFTH FLOOR) ---- etc., complete with all lead | m | 421.14 | 421.14 | 80.0 | False | None | None | False | None | False | 33691.2 | 0 | 3092247 | 106302 | None | code315 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes(FIFTH FLOOR) ---- etc., complete with all lead | m | 516.54 | 516.54 | 650.0 | False | None | None | False | None | False | 335751.0 | 0 | 3092248 | 106302 | None | code316 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipes(FIFTH FLOOR) ---- etc., complete with all lead | m | 650.1 | 650.1 | 320.0 | False | None | None | False | None | False | 208032.0 | 0 | 3092249 | 106302 | None | code317 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipes(FIFTH FLOOR) ---- etc., complete with all lead | m | 759.14 | 759.14 | 215.0 | False | None | None | False | None | False | 163215.1 | 0 | 3092250 | 106302 | None | code318 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 25mm DWS(FIFTH FLOOR) ---- etc., complete with all lead | m | 433.4 | 433.4 | 175.0 | False | None | None | False | None | False | 75845.0 | 0 | 3092251 | 106302 | None | code319 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 32mm DWS(FIFTH FLOOR) ---- etc., complete with all lead | m | 545.16 | 545.16 | 230.0 | False | None | None | False | None | False | 125386.8 | 0 | 3092252 | 106302 | None | code320 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 40 mm nominal dia Pipes(FIFTH FLOOR) ---- etc., complete with all lead | m | 730.51 | 730.51 | 180.0 | False | None | None | False | None | False | 131491.8 | 0 | 3092253 | 106302 | None | code321 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 50 mm nominal dia Pipes(FIFTH FLOOR) ---- etc., complete with all lead | m | 1064.42 | 1064.42 | 60.0 | False | None | None | False | None | False | 63865.2 | 0 | 3092254 | 106302 | None | code322 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40mm dia pipes, From wash basin waste lines(TERRACE FLOOR) ---- etc., complete with all lead | m | 418.27 | 418.27 | 65.0 | False | None | None | False | None | False | 27187.55 | 0 | 3092255 | 106302 | None | code323 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50mm dia pipes, From sink & urinal waste lines(TERRACE FLOOR) ---- etc., complete with all lead | m | 531.09 | 531.09 | 45.0 | False | None | None | False | None | False | 23899.05 | 0 | 3092256 | 106302 | None | code324 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 75mm nominal dia pipes (TERRACE FLOOR) ---- etc., complete with all lead | m | 397.63 | 397.63 | 135.0 | False | None | None | False | None | False | 53680.05 | 0 | 3092257 | 106302 | None | code325 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipes (TERRACE FLOOR) ---- etc., complete with all lead | m | 529.71 | 529.71 | 125.0 | False | None | None | False | None | False | 66213.75 | 0 | 3092258 | 106302 | None | code326 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.(TERRACE FLOOR) ---- etc., complete with all lead | Each | 1678.57 | 1678.57 | 11.0 | False | None | None | False | None | False | 18464.27 | 0 | 3092259 | 106302 | None | code327 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931(TERRACE FLOOR) ---- etc., complete with all lead | Each | 853.05 | 853.05 | 11.0 | False | None | None | False | None | False | 9383.55 | 0 | 3092260 | 106302 | None | code328 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.(TERRACE FLOOR) ---- etc., complete with all lead | Each | 997.51 | 997.51 | 2.0 | False | None | None | False | None | False | 1995.02 | 0 | 3092261 | 106302 | None | code329 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge.(TERRACE FLOOR) ---- etc., complete with all lead | Each | 1114.46 | 1114.46 | 11.0 | False | None | None | False | None | False | 12259.06 | 0 | 3092262 | 106302 | None | code330 | Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore)(TERRACE FLOOR) ---- etc., complete with all lead | Each | 114.2 | 114.2 | 11.0 | False | None | None | False | None | False | 1256.2 | 0 | 3092263 | 106302 | None | code331 | Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g(TERRACE FLOOR) ---- etc., complete with all lead | Each | 421.02 | 421.02 | 1.0 | False | None | None | False | None | False | 421.02 | 0 | 3092264 | 106302 | None | code332 | Providing and fixing brass bib cock of approved quality 15 mm nominal bore(TERRACE FLOOR) ---- etc., complete with all lead | Each | 393.5 | 393.5 | 6.0 | False | None | None | False | None | False | 2361.0 | 0 | 3092265 | 106302 | None | code333 | Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm x 7.5 cm x5.0 cm x 4.0 cm with all fitting arrangements & all necessary accessories complete(TERRACE FLOOR) ---- etc., complete with all lead | Each | 335.71 | 335.71 | 10.0 | False | None | None | False | None | False | 3357.1 | 0 | 3092266 | 106302 | None | code334 | Providing and fixing Liquid soap dispenser made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy(TERRACE FLOOR) ---- etc., complete with all lead | Each | 2402.29 | 2402.29 | 2.0 | False | None | None | False | None | False | 4804.58 | 0 | 3092267 | 106302 | None | code335 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipes(TERRACE FLOOR) ---- etc., complete with all lead | m | 425.15 | 425.15 | 30.0 | False | None | None | False | None | False | 12754.5 | 0 | 3092268 | 106302 | None | code336 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes(TERRACE FLOOR) ---- etc., complete with all lead | m | 521.46 | 521.46 | 80.0 | False | None | None | False | None | False | 41716.8 | 0 | 3092269 | 106302 | None | code337 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipes(TERRACE FLOOR) ---- etc., complete with all lead | m | 656.29 | 656.29 | 80.0 | False | None | None | False | None | False | 52503.2 | 0 | 3092270 | 106302 | None | code338 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipes(TERRACE FLOOR) ---- etc., complete with all lead | m | 766.37 | 766.37 | 65.0 | False | None | None | False | None | False | 49814.05 | 0 | 3092271 | 106302 | None | code339 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Internal work - Exposed on wall 25mm nominal dia pipes(TERRACE FLOOR) ---- etc., complete with all lead | m | 437.53 | 437.53 | 95.0 | False | None | None | False | None | False | 41565.35 | 0 | 3092272 | 106302 | None | code340 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Internal work - Exposed on wall 32mm nominal dia pipes(TERRACE FLOOR) ---- etc., complete with all lead | m | 550.35 | 550.35 | 95.0 | False | None | None | False | None | False | 52283.25 | 0 | 3092273 | 106302 | None | code341 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Internal work - Exposed on wall 40 mm nominal dia Pipes(TERRACE FLOOR) ---- etc., complete with all lead | m | 737.47 | 737.47 | 75.0 | False | None | None | False | None | False | 55310.25 | 0 | 3092274 | 106302 | None | code342 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Internal work - Exposed on wall 50 mm nominal dia Pipes(TERRACE FLOOR) ---- etc., complete with all lead | m | 1074.56 | 1074.56 | 70.0 | False | None | None | False | None | False | 75219.2 | 0 | 3092275 | 106302 | None | code343 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore(TERRACE FLOOR) ---- etc., complete with all lead | Each | 755.36 | 755.36 | 6.0 | False | None | None | False | None | False | 4532.16 | 0 | 3092276 | 106302 | None | code344 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 32 mm nominal bore(TERRACE FLOOR) ---- etc., complete with all lead | Each | 817.27 | 817.27 | 4.0 | False | None | None | False | None | False | 3269.08 | 0 | 3092277 | 106302 | None | code345 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 40 mm nominal bore(TERRACE FLOOR) ---- etc., complete with all lead | Each | 965.87 | 965.87 | 2.0 | False | None | None | False | None | False | 1931.74 | 0 | 3092278 | 106302 | None | code346 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 50 mm nominal bore(TERRACE FLOOR) ---- etc., complete with all lead | Each | 1176.38 | 1176.38 | 2.0 | False | None | None | False | None | False | 2352.76 | 0 | 3092279 | 106302 | None | code347 | Providing and fixing brass bib cock of approved quality 15 mm nominal bore(TERRACE FLOOR) ---- etc., complete with all lead | Each | 393.5 | 393.5 | 6.0 | False | None | None | False | None | False | 2361.0 | 0 |
| 1710501218000 | 0 | None | None | Buildings | HVAC Works | 40015534.6 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3092280 | 106303 | None | code01 | Supplying of .. TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed inverter compressor with air cooled condenser, latest R410A / R-32 refrigerant fan motor, start & run capacitors, relay & over load protector internal unit, with one indoor & one outdoor unit The condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit.5 star
1 Ton capacity ---- etc., complete with all lead | No | 56117.26 | 56117.26 | 13.0 | False | None | None | False | None | False | 729524.38 | 0 | 3092281 | 106303 | None | code02 | Supplying of .. TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed inverter compressor with air cooled condenser, latest R410A / R-32 refrigerant fan motor, start & run capacitors, relay & over load protector internal unit, with one indoor & one outdoor unit The condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit.5 star
1.5 Ton capacity ---- etc., complete with all lead | No | 66498.9 | 66498.9 | 14.0 | False | None | None | False | None | False | 930984.6 | 0 | 3092282 | 106303 | None | code03 | Supplying of .. TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed inverter compressor with air cooled condenser, latest R410A / R-32 refrigerant fan motor, start & run capacitors, relay & over load protector internal unit, with one indoor & one outdoor unit The condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit.5 star
2 Ton capacity ---- etc., complete with all lead | No | 79530.82 | 79530.82 | 26.0 | False | None | None | False | None | False | 2067801.32 | 0 | 3092283 | 106303 | None | code04 | Supply erection, testing, commissioning of Cassette type split Air conditioners suitable for operation on single/three phase AC supply, hermetically sealed compressor with air cooled condenser motor capacitor start, capacitors run relay and over load protection, one ceiling mounted indoor unit and one outdoor condenser unit including standard accessories covered with insulation tube including battery operated cordless unit
2.0 TR Cassette 1 Ph ---- etc., complete with all lead | No | 93001.7 | 93001.7 | 11.0 | False | None | None | False | None | False | 1023018.7 | 0 | 3092284 | 106303 | None | code05 | Supply erection, testing, commissioning of Cassette type split Air conditioners suitable for operation on single/three phase AC supply, hermetically sealed compressor with air cooled condenser motor capacitor start, capacitors run relay and over load protection, one ceiling mounted indoor unit and one outdoor condenser unit including standard accessories covered with insulation tube including battery operated cordless unit
3.0 TR Cassette 3 Ph ---- etc., complete with all lead | No | 124038.06 | 124038.06 | 7.0 | False | None | None | False | None | False | 868266.42 | 0 | 3092285 | 106303 | None | code06 | Supplying, Erecting, Testing, commissioning package type Duct able type split Air-Conditioner with microprocessor control, fitted with twin scroll Compressor with R22/Latest Refrigerant The unit shall be pre-wired to operate on 415V, 50Hz AC Supply. The unit shall comprise, Evaporated condenser unit, Indoor-Outdoor Motor Fans, suitable over vent fins made up of Aluminium, Copper Refrigerant coil, Etc.,. complete and corded control unit.
5.5TR ---- etc., complete with all lead | No | 133468.62 | 133468.62 | 2.0 | False | None | None | False | None | False | 266937.24 | 0 | 3092286 | 106303 | None | code07 | Supplying, Erecting, Testing, commissioning package type Duct able type split Air-Conditioner with microprocessor control, fitted with twin scroll Compressor with R22/Latest Refrigerant The unit shall be pre-wired to operate on 415V, 50Hz AC Supply. The unit shall comprise, Evaporated condenser unit, Indoor-Outdoor Motor Fans, suitable over vent fins made up of Aluminium, Copper Refrigerant coil, Etc.,. complete and corded control unit.
8.5TR ---- etc., complete with all lead | No | 191847.94 | 191847.94 | 1.0 | False | None | None | False | None | False | 191847.94 | 0 | 3092287 | 106303 | None | code08 | Supplying, Erecting, Testing, commissioning package type Duct able type split Air-Conditioner with microprocessor control, fitted with twin scroll Compressor with R22/Latest Refrigerant The unit shall be pre-wired to operate on 415V, 50Hz AC Supply. The unit shall comprise, Evaporated condenser unit, Indoor-Outdoor Motor Fans, suitable over vent fins made up of Aluminium, Copper Refrigerant coil, Etc.,. complete and corded control unit.
11TR ---- etc., complete with all lead | No | 250296.88 | 250296.88 | 1.0 | False | None | None | False | None | False | 250296.88 | 0 | 3092288 | 106303 | None | code09 | Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A/C. ---- etc., complete with all lead | No | 3746.5 | 3746.5 | 53.0 | False | None | None | False | None | False | 198564.5 | 0 | 3092289 | 106303 | None | code10 | Supplying and installation of insulated refrigerant copper tubing of 5/8 and 3/8 with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas charging for additional piping length of tube.
Split ---- etc., complete with all lead | Rmtr | 1827.82 | 1827.82 | 546.0 | False | None | None | False | None | False | 997989.72 | 0 | 3092290 | 106303 | None | code11 | Supplying and installation of insulated refrigerant copper tubing of 5/8 and 3/8 with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas charging for additional piping length of tube.
Cassette ---- etc., complete with all lead | Rmtr | 1934.02 | 1934.02 | 288.0 | False | None | None | False | None | False | 556997.76 | 0 | 3092291 | 106303 | None | code12 | Supply, installation of 5/8 and 7/8 Hard drawn refrigerant pipe and insulation suitable for 11TR ductable split Air- Conditioner. ---- etc., complete with all lead | Rmtr | 2636.12 | 2636.12 | 61.0 | False | None | None | False | None | False | 160803.32 | 0 | 3092292 | 106303 | None | code13 | Supply, fabrication and installation of GI Ducting Along with flanges, supports & all fixing materials.
24 Gauge ---- etc., complete with all lead | Sqm | 2136.98 | 2136.98 | 2480.0 | False | None | None | False | None | False | 5299710.4 | 0 | 3092293 | 106303 | None | code14 | Supply, fabrication and installation of GI Ducting Along with flanges, supports & all fixing materials.
22Gauge ---- etc., complete with all lead | Sqm | 2502.78 | 2502.78 | 240.0 | False | None | None | False | None | False | 600667.2 | 0 | 3092294 | 106303 | None | code15 | Supply and installation of Thermal insulation using 13mm nitrile rubber for return air ducts. ---- etc., complete with all lead | Sqm | 1405.38 | 1405.38 | 2055.0 | False | None | None | False | None | False | 2888055.9 | 0 | 3092295 | 106303 | None | code16 | Supply and installation of Tarpaulin canvas between the AC duct and AC evaporator unit including accessories. ---- etc., complete with all lead | No | 5385.52 | 5385.52 | 18.0 | False | None | None | False | None | False | 96939.36 | 0 | 3092296 | 106303 | None | code17 | Supply and installation of Powder coated aluminium diffusers of size 595x595mm for supply & return air.Aluminium Diffusers ---- etc., complete with all lead | No | 5992.04 | 5992.04 | 444.0 | False | None | None | False | None | False | 2660465.76 | 0 | 3092297 | 106303 | None | code18 | Collar Dampers ---- etc., complete with all lead | No | 3096.32 | 3096.32 | 235.0 | False | None | None | False | None | False | 727635.2 | 0 | 3092298 | 106303 | None | code19 | GI Mixing Box ---- etc., complete with all lead | No | 7404.5 | 7404.5 | 110.0 | False | None | None | False | None | False | 814495.0 | 0 | 3092299 | 106303 | None | code20 | Flexible Duct Per Mtr ---- etc., complete with all lead | No | 1996.56 | 1996.56 | 180.0 | False | None | None | False | None | False | 359380.8 | 0 | 3092300 | 106303 | None | code21 | Supply and fixing of powder coated extruded aluminium grill suitable for supply/return air including all fixing hardware etc.,. Complete.
6 extruded aluminium grill with 15 deg to 30 deg louvers ---- etc., complete with all lead | Rmtr | 2008.36 | 2008.36 | 105.0 | False | None | None | False | None | False | 210877.8 | 0 | 3092301 | 106303 | None | code22 | Supplying push button operated direct online starter with anantiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overloadrelay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for230/440 V 1/3 phase motor upto 5 HP. ---- etc., complete with all lead | No | 2273.86 | 2273.86 | 15.0 | False | None | None | False | None | False | 34107.9 | 0 | 3092302 | 106303 | None | code23 | Supply, Installation, Testing and Commissioning of Customized Double Skin Horizontal Ceiling Mounted type Air Handling Units with Thermal Break profile. (Direct Expansion (DX) refrigerant-to-air evaporator coils, as applied with condensing units with necessary KIT) Sandwitched between 0.8 precoated GI (outer skin) shall be pre coated and 0.8 Plain GI (inner skin) double skin (482 mm) insulated with CFC free polyurethane +/-foam (PUF) panels of 40 Kg/cum density. AHU frame works shall be of pre cast vertical and horizontal extruded thermal break aluminium profile with three way corner frame sections. Food grade self adhesive coated neoprene gasket to be provided between panels and structure of the AHU to ensure the entire housing is airtight. DIDW centrifugal belt driven backward Aerofoil curved impeller fans (Efficiency with 75%) (AMCA Certified) to be supplied along with motor.The outlet velocity will not exceed 9.5 m/sec. Vibration isolatator to fans and motor to avoid transmission of vibration. AHRI Certified DX Cooling coils shall be of minimum 6/8 Row deep or as per computer coil selections which ever is greater. Face Velocity across the coils should not exceed 500 FPM (2.5m/s) (Note : DX Cooling Coil should be Hydrophlic blue aluminium fines.) The AHU unit shall be complete with external DX type condensing unit, complete in all respects, inclusive of complete working charge of R410a/134a Chlorofluorocarbons (CFC) environmentally free refrigerant.Drain tray for DX cooling coils shall be made of single sheet of SS 304-20G grade stainless steel sheet and should have uniform slope from all sides leading to drain connection. Drain Pan shall be insulated with 19mm thick, 55kg/cum density closed cell elastomeric insulation. Each unit filters section shall be provided with a factory assembled filter section containing washable synthetic with 50mm thick panel type Pre-Filter of MERV 8 (EU-4)- 90% down to 10 microns. (1 set of spare & 1 set of commissioning pre filters should be consider) and Fine-Filter of MERV 13 (EU-7) 97% down to 3 microns. The Motor shall be of TEFC, IP-65 protected, IE-3, Class 'F' insulation, suitable for 3 phase, 415 volts, 50hz power supply. Motor shall be VFD compatible and induction type. Costing is inclusive of Canvas connection made of self extinguishing, moisture resistant flexible fabric to be provided between AHU outlet flange and the supply duct / plenum, communication cable as specfied by manufacturer and Lifting, Shifting & Positioning with MS L angle base frame structure duly black painted with synthetic epoxy paint for all outdoor units. Wiring and earthing, vacuum cleaneing, gas charging, pressure testing and etc… are in part of HVAC Vendor scope.Safety interlock switch for fan operation to controle heater on/off to be provided by the AHU manufacturer. Note : Costing is inclusive of Necessary DX type condensing out door units to AHU interface Expansion Connecting Kit (PCB with EEV) & Control Control Panel with sensors, thermostat and etc.., Corded Remote controller for AHU's to precisely control the flow of refrigerant for temperature control.
5.5 TR / 2,200 CFM with 50 TSP - 1.5 Kw for CSU's and 1x5.5 - Condensing units with necessary KIT ---- etc., complete with all lead | No | 169212.0 | 169212.0 | 4.0 | False | None | None | False | None | False | 676848.0 | 0 | 3092303 | 106303 | None | code24 | Supply, Installation, Testing and Commissioning of Customized Double Skin Horizontal Ceiling Mounted type Air Handling Units with Thermal Break profile. (Direct Expansion (DX) refrigerant-to-air evaporator coils, as applied with condensing units with necessary KIT) Sandwitched between 0.8 precoated GI (outer skin) shall be pre coated and 0.8 Plain GI (inner skin) double skin (48+/-2 mm) insulated with CFC free polyurethane foam (PUF) panels of 40 Kg/cum density. AHU frame works shall be of pre cast vertical and horizontal extruded thermal break aluminium profile with three way corner frame sections. Food grade self adhesive coated neoprene gasket to be provided between panels and structure of the AHU to ensure the entire housing is airtight. DIDW centrifugal belt driven backward Aerofoil curved impeller fans (Efficiency with 75%) (AMCA Certified) to be supplied along with motor.The outlet velocity will not exceed 9.5 m/sec. Vibration isolatator to fans and motor to avoid transmission of vibration. AHRI Certified DX Cooling coils shall be of minimum 6/8 Row deep or as per computer coil selections which ever is greater. Face Velocity across the coils should not exceed 500 FPM (2.5m/s) (Note : DX Cooling Coil should be Hydrophlic blue aluminium fines.) The AHU unit shall be complete with external DX type condensing unit, complete in all respects, inclusive of complete working charge of R410a/134a Chlorofluorocarbons (CFC) environmentally free refrigerant.Drain tray for DX cooling coils shall be made of single sheet of SS 304-20G grade stainless steel sheet and should have uniform slope from all sides leading to drain connection. Drain Pan shall be insulated with 19mm thick, 55kg/cum density closed cell elastomeric insulation. Each unit filters section shall be provided with a factory assembled filter section containing washable synthetic with 50mm thick panel type Pre-Filter of MERV 8 (EU-4)- 90% down to 10 microns. (1 set of spare & 1 set of commissioning pre filters should be consider) and Fine-Filter of MERV 13 (EU-7) 97% down to 3 microns. The Motor shall be of TEFC, IP-65 protected, IE-3, Class 'F' insulation, suitable for 3 phase, 415 volts, 50hz power supply. Motor shall be VFD compatible and induction type. Costing is inclusive of Canvas connection made of self extinguishing, moisture resistant flexible fabric to be provided between AHU outlet flange and the supply duct / plenum, communication cable as specfied by manufacturer and Lifting, Shifting & Positioning with MS L angle base frame structure duly black painted with synthetic epoxy paint for all outdoor units. Wiring and earthing, vacuum cleaneing, gas charging, pressure testing and etc… are in part of HVAC Vendor scope.Safety interlock switch for fan operation to controle heater on/off to be provided by the AHU manufacturer. Note : Costing is inclusive of Necessary DX type condensing out door units to AHU interface Expansion Connecting Kit (PCB with EEV) & Control Control Panel with sensors, thermostat and etc.., Corded Remote controller for AHU's to precisely control the flow of refrigerant for temperature control.
8.5 TR / 3,400 CFM with 50 TSP - 1.5 Kw for CSU's and 1x8.5 - Condensing units with necessary KIT. ---- etc., complete with all lead | No | 206972.0 | 206972.0 | 5.0 | False | None | None | False | None | False | 1034860.0 | 0 | 3092304 | 106303 | None | code25 | Supply, Installation, Testing and Commissioning of Customized Double Skin Horizontal Ceiling Mounted type Air Handling Units with Thermal Break profile. (Direct Expansion (DX) refrigerant-to-air evaporator coils, as applied with condensing units with necessary KIT) Sandwitched between 0.8 precoated GI (outer skin) shall be pre coated and 0.8 Plain GI (inner skin) double skin (48+/-2 mm) insulated with CFC free polyurethane foam (PUF) panels of 40 Kg/cum density. AHU frame works shall be of pre cast vertical and horizontal extruded thermal break aluminium profile with three way corner frame sections. Food grade self adhesive coated neoprene gasket to be provided between panels and structure of the AHU to ensure the entire housing is airtight. DIDW centrifugal belt driven backward Aerofoil curved impeller fans (Efficiency with 75%) (AMCA Certified) to be supplied along with motor.The outlet velocity will not exceed 9.5 m/sec. Vibration isolatator to fans and motor to avoid transmission of vibration. AHRI Certified DX Cooling coils shall be of minimum 6/8 Row deep or as per computer coil selections which ever is greater. Face Velocity across the coils should not exceed 500 FPM (2.5m/s) (Note : DX Cooling Coil should be Hydrophlic blue aluminium fines.) The AHU unit shall be complete with external DX type condensing unit, complete in all respects, inclusive of complete working charge of R410a/134a Chlorofluorocarbons (CFC) environmentally free refrigerant.Drain tray for DX cooling coils shall be made of single sheet of SS 304-20G grade stainless steel sheet and should have uniform slope from all sides leading to drain connection. Drain Pan shall be insulated with 19mm thick, 55kg/cum density closed cell elastomeric insulation. Each unit filters section shall be provided with a factory assembled filter section containing washable synthetic with 50mm thick panel type Pre-Filter of MERV 8 (EU-4)- 90% down to 10 microns. (1 set of spare & 1 set of commissioning pre filters should be consider) and Fine-Filter of MERV 13 (EU-7) 97% down to 3 microns. The Motor shall be of TEFC, IP-65 protected, IE-3, Class 'F' insulation, suitable for 3 phase, 415 volts, 50hz power supply. Motor shall be VFD compatible and induction type. Costing is inclusive of Canvas connection made of self extinguishing, moisture resistant flexible fabric to be provided between AHU outlet flange and the supply duct / plenum, communication cable as specfied by manufacturer and Lifting, Shifting & Positioning with MS L angle base frame structure duly black painted with synthetic epoxy paint for all outdoor units. Wiring and earthing, vacuum cleaneing, gas charging, pressure testing and etc… are in part of HVAC Vendor scope.Safety interlock switch for fan operation to controle heater on/off to be provided by the AHU manufacturer. Note : Costing is inclusive of Necessary DX type condensing out door units to AHU interface Expansion Connecting Kit (PCB with EEV) & Control Control Panel with sensors, thermostat and etc.., Corded Remote controller for AHU's to precisely control the flow of refrigerant for temperature control. 11.0 TR / 4,400 CFM with 50 TSP - 2.2 Kw for CSU's and 1x11.0 - Condensing units with necessary KIT. ---- etc., complete with all lead | No | 252284.0 | 252284.0 | 2.0 | False | None | None | False | None | False | 504568.0 | 0 | 3092305 | 106303 | None | code26 | Supply, Installation, Testing and Commissioning of Double Skin Horizontal Ceiling/Floor Mounted Cabinet type Fresh air Units Sandwitched between 0.6 precoated GI (outer skin) shall be pre coated and 0.6 Plain GI (inner skin) double skin (23+/-2 mm) insulated with CFC free polyurethane foam (PUF) panels of 40 Kg/cum density. with DIDW centrifugal belt driven backward curved Aerofoil impeller fans (Efficiency with 75%) (AMCA Certified) to be supplied along with motor. Vibration isolatator to fans and motor to avoid transmission of vibration, Motor, Pulleys, Belts & Belt guard, Pre-Filter of MERV 8 (EU-4)- 90% down to 10 microns. Drive sets, base frame, spring mounts, Limit switches, Marine lamp, Inspection door and all necessary accessories.Blower Make - Nicotra / Kruger.
The unit shall be suitable for outdoor application with necessary weather hood, canopy and supports with necessary MS channels & threaded rods.
The Motor shall be of TEFC, IP-55 protected, IE-3, Class 'F' insulation, suitable for 3 phase, 415 volts, 50hz power supply.
Motor shall be VFD compatible and induction type. VFD starter panel cost quantified separately (Cost excluded for the same).Costing is inclusive of Factory fabricated non-cloth type Fire retardant flexible connection made of high quality self extinguishing, moisture resistant flexible fabric with matching angle flanges between Fresh air units outlet flange and the connected plenum or ducts.
1,000 CFM / 40 mm TSP / 1.1 kW ---- etc., complete with all lead | No | 41300.0 | 41300.0 | 2.0 | False | None | None | False | None | False | 82600.0 | 0 | 3092306 | 106303 | None | code27 | Supply, Installation, Testing and Commissioning of Double Skin Horizontal Ceiling/Floor Mounted Cabinet type Fresh air Units Sandwitched between 0.6 precoated GI (outer skin) shall be pre coated and 0.6 Plain GI (inner skin) double skin (23+/-2 mm) insulated with CFC free polyurethane foam (PUF) panels of 40 Kg/cum density. with DIDW centrifugal belt driven backward curved Aerofoil impeller fans (Efficiency with 75%) (AMCA Certified) to be supplied along with motor. Vibration isolatator to fans and motor to avoid transmission of vibration, Motor, Pulleys, Belts & Belt guard, Pre-Filter of MERV 8 (EU-4)- 90% down to 10 microns. Drive sets, base frame, spring mounts, Limit switches, Marine lamp, Inspection door and all necessary accessories.Blower Make - Nicotra / Kruger.
The unit shall be suitable for outdoor application with necessary weather hood, canopy and supports with necessary MS channels & threaded rods.
The Motor shall be of TEFC, IP-55 protected, IE-3, Class 'F' insulation, suitable for 3 phase, 415 volts, 50hz power supply.
Motor shall be VFD compatible and induction type. VFD starter panel cost quantified separately (Cost excluded for the same).Costing is inclusive of Factory fabricated non-cloth type Fire retardant flexible connection made of high quality self extinguishing, moisture resistant flexible fabric with matching angle flanges between Fresh air units outlet flange and the connected plenum or ducts.
1,500 CFM / 40 mm TSP / 1.1 kW ---- etc., complete with all lead | No | 61360.0 | 61360.0 | 2.0 | False | None | None | False | None | False | 122720.0 | 0 | 3092307 | 106303 | None | code28 | Supply, Installation, Testing and Commissioning of Double Skin Horizontal Ceiling/Floor Mounted Cabinet type Fresh air Units Sandwitched between 0.6 precoated GI (outer skin) shall be pre coated and 0.6 Plain GI (inner skin) double skin (23+/-2 mm) insulated with CFC free polyurethane foam (PUF) panels of 40 Kg/cum density. with DIDW centrifugal belt driven backward curved Aerofoil impeller fans (Efficiency with 75%) (AMCA Certified) to be supplied along with motor. Vibration isolatator to fans and motor to avoid transmission of vibration, Motor, Pulleys, Belts & Belt guard, Pre-Filter of MERV 8 (EU-4)- 90% down to 10 microns. Drive sets, base frame, spring mounts, Limit switches, Marine lamp, Inspection door and all necessary accessories.Blower Make - Nicotra / Kruger.
The unit shall be suitable for outdoor application with necessary weather hood, canopy and supports with necessary MS channels & threaded rods.
The Motor shall be of TEFC, IP-55 protected, IE-3, Class 'F' insulation, suitable for 3 phase, 415 volts, 50hz power supply.
Motor shall be VFD compatible and induction type. VFD starter panel cost quantified separately (Cost excluded for the same).Costing is inclusive of Factory fabricated non-cloth type Fire retardant flexible connection made of high quality self extinguishing, moisture resistant flexible fabric with matching angle flanges between Fresh air units outlet flange and the connected plenum or ducts.The fresh air fan is controlled from push button switch located in the kitchen.The push button switch, starter panel & controle cable (between starter panel & push button) & power cable (between starter panel & Fan) is in HVAC contractor scope of work. 12,000 CFM / 50 mm TSP (Approx) / 5.5 kW (Approx) ---- etc., complete with all lead | No | 472000.0 | 472000.0 | 1.0 | False | None | None | False | None | False | 472000.0 | 0 | 3092308 | 106303 | None | code29 | Supply, Installing, testing and commissioning of SISW Blower (AMCA Certified) made of 14 SWG , MS sheet with Backward curved impeller, Impeller will be statically & dynamically balanced . The blower casing internal will be epoxy coated. The blower externals will be painted with 2 coats of the zinc chromate primer and finished with weather proof paint of 2coats. The outlet velocity will not exceed 10 m/sec. The unit will have drain plug at the bottom for draining the oil (Motor Make : ABB / Crompton greaves / Kirloskar).Static pressure and Motor Rating : The Indicated static pressure and motor rating is only provisional. Contractor to calculate static pressure based on final approved construction shop drawing and pressure drop of finalized Equipment / Items and submit for review / approval to the consultants. The procurement shall be processed only after duly verification / approval of calculation and selection from the consultants.Note : HVAC vendors has to take approval from the Client / Architects / Consultants prior to manufacture of units. Also site visit to be done before manufacturing the units. Based on the site condition units sizes (foot print) and selection should happen. The Exhaust air fan is controlled from push button switch located in the kitchen.The push button switch, starter panel & controle cable (between starter panel & push button) & power cable (between starter panel & Fan) is in HVAC contractor scope of work. 15,000 CFM / 100 mm TSP (Approx) / 9.3 kW (Approx) ---- etc., complete with all lead | No | 590000.0 | 590000.0 | 1.0 | False | None | None | False | None | False | 590000.0 | 0 | 3092309 | 106303 | None | code30 | Supply, Installing, testing and commissioning of Electrostatic Precipitation based Dry Type Scrubber each comprising of extract air intake section, electrostatic precipitation technology, dry type air cleaner to remove oil, smoke and fumes from exhaust air.
Electrostatic section shall be made of 16 gauge galvanised sheet, high bake epoxy powder coated, washable type aluminium mesh filters, stainless steel spiked ionizers to create high voltage DC field, aluminum collector plates which should be alternatively charged positive and negative with large collecting area with 14 deep cell, to work as magnet for charged smoke and oil particles. Average efficiency of 90-95% in single pass as per ASHRAE test method. Electrostatic Precipitator should be able to charge particles from 0.01 micron to 10 microns through solid state power supply. Collector cell should be of permanent type and incorporate slide out facility for easy removal for cleaning. Power supplies shall be 100% solid state UL Listed, Module of capacity above 3000 CFM shall be equipped with Pulse width modulating (PWM).The system should be fitted with interlock switch for safety . The system should allow connection to a fan section to achieve 500 FPM velocity across the air cleaner.Motor should be acoustically treated to reduce noise level.The power supply to Dry scrubber should be from kitchen Exhaust starter panel.Necessary power and controle cable is in HVAC contractor scope of work.
Operating Voltage : 220V, 50 Hz.
Ionizing Voltage : 12.5 to 13 KVDC.
Collector Cell Voltage : 6 to 6.5 KVDC.
Power Consumption : Not more than 85W per cell.
7,500 CFM ---- etc., complete with all lead | No | 413000.0 | 413000.0 | 2.0 | False | None | None | False | None | False | 826000.0 | 0 | 3092310 | 106303 | None | code31 | Supply, Installation, Testing & Commissioning of Rectangular / Circular inline fan with variable speed regulator with suitable for installing in any position in vertical or horizontal ducts. All accessories like fan, motor, flanges, non-canvass type fire retardant flexible connections, etc., The impeller shall be of forward type. The motor should be of IP21, class 'B' insulation suitable for operating at 1phase, 230V, 50hz power supply.
Note : Rectangular / Circular inline fan shall have low sound level exceeding not more than 40 dBA at 1 meter distance.
Note: Costing is inclusive of Factory fabricated non-cloth type Fire retardant flexible connection made of high quality self extinguishing, moisture resistant flexible fabric with matching angle flanges between Fresh/Exhaut air units outlet flange and the connected plenum or ducts.
150 CFM / 20mm TSP. ---- etc., complete with all lead | No | 12980.0 | 12980.0 | 2.0 | False | None | None | False | None | False | 25960.0 | 0 | 3092311 | 106303 | None | code32 | Supply, Installation, Testing & Commissioning of Rectangular / Circular inline fan with variable speed regulator with suitable for installing in any position in vertical or horizontal ducts. All accessories like fan, motor, flanges, non-canvass type fire retardant flexible connections, etc., The impeller shall be of forward type. The motor should be of IP21, class 'B' insulation suitable for operating at 1phase, 230V, 50hz power supply.
Note : Rectangular / Circular inline fan shall have low sound level exceeding not more than 40 dBA at 1 meter distance.
Note: Costing is inclusive of Factory fabricated non-cloth type Fire retardant flexible connection made of high quality self extinguishing, moisture resistant flexible fabric with matching angle flanges between Fresh/Exhaut air units outlet flange and the connected plenum or ducts.
300 CFM / 20mm TSP. ---- etc., complete with all lead | No | 15340.0 | 15340.0 | 2.0 | False | None | None | False | None | False | 30680.0 | 0 | 3092312 | 106303 | None | code33 | Supply, Installation, Testing & Commissioning of Rectangular / Circular inline fan with variable speed regulator with suitable for installing in any position in vertical or horizontal ducts. All accessories like fan, motor, flanges, non-canvass type fire retardant flexible connections, etc., The impeller shall be of forward type. The motor should be of IP21, class 'B' insulation suitable for operating at 1phase, 230V, 50hz power supply.
Note : Rectangular / Circular inline fan shall have low sound level exceeding not more than 40 dBA at 1 meter distance.
Note: Costing is inclusive of Factory fabricated non-cloth type Fire retardant flexible connection made of high quality self extinguishing, moisture resistant flexible fabric with matching angle flanges between Fresh/Exhaut air units outlet flange and the connected plenum or ducts.
500 CFM / 20mm TSP. ---- etc., complete with all lead | No | 17700.0 | 17700.0 | 2.0 | False | None | None | False | None | False | 35400.0 | 0 | 3092313 | 106303 | None | code34 | Supply, Installation, Testing & Commissioning of Rectangular / Circular inline fan with variable speed regulator with suitable for installing in any position in vertical or horizontal ducts. All accessories like fan, motor, flanges, non-canvass type fire retardant flexible connections, etc., The impeller shall be of forward type. The motor should be of IP21, class 'B' insulation suitable for operating at 1phase, 230V, 50hz power supply.
Note : Rectangular / Circular inline fan shall have low sound level exceeding not more than 40 dBA at 1 meter distance.
Note: Costing is inclusive of Factory fabricated non-cloth type Fire retardant flexible connection made of high quality self extinguishing, moisture resistant flexible fabric with matching angle flanges between Fresh/Exhaut air units outlet flange and the connected plenum or ducts.
600 CFM / 20mm TSP. ---- etc., complete with all lead | No | 20060.0 | 20060.0 | 2.0 | False | None | None | False | None | False | 40120.0 | 0 | 3092314 | 106303 | None | code35 | Supply, Installation, Testing & Commissioning of Rectangular / Circular inline fan with variable speed regulator with suitable for installing in any position in vertical or horizontal ducts. All accessories like fan, motor, flanges, non-canvass type fire retardant flexible connections, etc., The impeller shall be of forward type. The motor should be of IP21, class 'B' insulation suitable for operating at 1phase, 230V, 50hz power supply.
Note : Rectangular / Circular inline fan shall have low sound level exceeding not more than 40 dBA at 1 meter distance.
Note: Costing is inclusive of Factory fabricated non-cloth type Fire retardant flexible connection made of high quality self extinguishing, moisture resistant flexible fabric with matching angle flanges between Fresh/Exhaut air units outlet flange and the connected plenum or ducts..
750 CFM / 20mm TSP. ---- etc., complete with all lead | No | 23600.0 | 23600.0 | 2.0 | False | None | None | False | None | False | 47200.0 | 0 | 3092315 | 106303 | None | code36 | Supply, installation, testing and commissioning of Interconnecting Soft drawn / Hard drawn Refrigerant copper Piping with insulation with UV protection coating.
Note:
a) To protect Nitrile rubber insulation of outdoor installed copper piping from degradation due to ultra violet rays and atmospheric condition.
b) UV protection coating on existing copper pipes (with insulation) shall be done with the help of starbond and 7mm cloth etc. UV protection coating shall be done on all the pipes irrespective of size of pipes work duly insulated with 13mm & 19mm thick elastomeric nitrile rubber type tubular insulation between VRV/VRF/DX Type indoor & outdoor units.
Note :
a) Costing is inclusive of necessary supports & supporting rods, saddles at 1m interval.
b) Refrigerant copper Piping quantity (Rmtr) to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.
c) Actual measurement of Refrigerant copper Piping quantity (Rmtr) should be taken as per site condition only.
1/4 (6.35 mm) X 21 Swg (0.8 mm) - Soft drawn (Insulation = 13mm thick) ---- etc., complete with all lead | Rmtr | 1357.0 | 1357.0 | 255.0 | False | None | None | False | None | False | 346035.0 | 0 | 3092316 | 106303 | None | code37 | Supply, installation, testing and commissioning of Interconnecting Soft drawn / Hard drawn Refrigerant copper Piping with insulation with UV protection coating.
Note:
a) To protect Nitrile rubber insulation of outdoor installed copper piping from degradation due to ultra violet rays and atmospheric condition.
b) UV protection coating on existing copper pipes (with insulation) shall be done with the help of starbond and 7mm cloth etc. UV protection coating shall be done on all the pipes irrespective of size of pipes work duly insulated with 13mm & 19mm thick elastomeric nitrile rubber type tubular insulation between VRV/VRF/DX Type indoor & outdoor units.
Note :
a) Costing is inclusive of necessary supports & supporting rods, saddles at 1m interval.
b) Refrigerant copper Piping quantity (Rmtr) to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.
c) Actual measurement of Refrigerant copper Piping quantity (Rmtr) should be taken as per site condition only.
1/2 (12.7 mm) X 21 Swg (0.8 mm) - Soft drawn (Insulation = 13mm thick) ---- etc., complete with all lead | Rmtr | 1534.0 | 1534.0 | 480.0 | False | None | None | False | None | False | 736320.0 | 0 | 3092317 | 106303 | None | code38 | Supply, installation, testing and commissioning of Interconnecting Soft drawn / Hard drawn Refrigerant copper Piping with insulation with UV protection coating.
Note:
a) To protect Nitrile rubber insulation of outdoor installed copper piping from degradation due to ultra violet rays and atmospheric condition.
b) UV protection coating on existing copper pipes (with insulation) shall be done with the help of starbond and 7mm cloth etc. UV protection coating shall be done on all the pipes irrespective of size of pipes work duly insulated with 13mm & 19mm thick elastomeric nitrile rubber type tubular insulation between VRV/VRF/DX Type indoor & outdoor units.
Note :
a) Costing is inclusive of necessary supports & supporting rods, saddles at 1m interval.
b) Refrigerant copper Piping quantity (Rmtr) to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.
c) Actual measurement of Refrigerant copper Piping quantity (Rmtr) should be taken as per site condition only.
7/8 ( 22.2 mm) X 19 Swg (1 mm) - Hard drawn (Insulation = 19mm thick) ---- etc., complete with all lead | Rmtr | 1976.5 | 1976.5 | 115.0 | False | None | None | False | None | False | 227297.5 | 0 | 3092318 | 106303 | None | code39 | Supply, installation, testing and commissioning of Interconnecting Soft drawn / Hard drawn Refrigerant copper Piping with insulation with UV protection coating.
Note:
a) To protect Nitrile rubber insulation of outdoor installed copper piping from degradation due to ultra violet rays and atmospheric condition.
b) UV protection coating on existing copper pipes (with insulation) shall be done with the help of starbond and 7mm cloth etc. UV protection coating shall be done on all the pipes irrespective of size of pipes work duly insulated with 13mm & 19mm thick elastomeric nitrile rubber type tubular insulation between VRV/VRF/DX Type indoor & outdoor units.
Note :
a) Costing is inclusive of necessary supports & supporting rods, saddles at 1m interval.
b) Refrigerant copper Piping quantity (Rmtr) to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.
c) Actual measurement of Refrigerant copper Piping quantity (Rmtr) should be taken as per site condition only..
1.0 (25.4 mm) X 19 Swg (1 mm) - Hard drawn (Insulation = 19mm thick) ---- etc., complete with all lead | Rmtr | 2124.0 | 2124.0 | 110.0 | False | None | None | False | None | False | 233640.0 | 0 | 3092319 | 106303 | None | code40 | Supply, Installation, Testing & Commissioning of Galvanized duct-Class VIII with zinc coating of 120 gm / Sqmt surface area as per IS-277. With TDF/TDC Flange system with factory fabricated Box section with neoprene rubber gaskets of thickness to match the dimensions of the ducts shall be used for connecting two ducts.Duct construction and installation shall be in accordance with SMACNA codes and Standards and all ducts testing pressure should be 500 Pascal. (pa).All ducting shall be of factory fabricated completely finished and transported to site in a boxed form (including the duct flange and the VAV transition pieces, grille / slot / diffusers plenum boxes, Z pieces and etc..)
The Duct shall be supported with GI steel Rods & MS angle Supports at regular minimum 2500mm intervals.
Ducts should be factory fabricated & Transportation should be in box section only to site. in site the duct needs to be stored in proper manner & covered with polythene sheets to avoid dust accumulation.
G.I. Sheet Make - Tata / Sail / Jindal / Vizag Steel.
Ducts sizes from and above 1200mm width should have Tie rods placed as per the standards with gasket and sealant to avoid the duct Bulging and Bulge out. These ducting quintettes are including of slot / diffusers plenum boxes with necessary threaded rods for supporting & anchor fasten. Vendor need to consider while quoting.All accessories like sealant, vanes, flanges, suspension rods , anchor bolts, GI bolts & nuts, canvas connections & splitter dampers etc.,. Costing is inclusive of MS angle Supports at regular intervals, threaded rod supports, angle flanges, anchor fastners, hot dipped galvanized bolts & nuts. Scaffolding arrangements to install the ducts and air terminals etc., Costing is inclusive of Scaffolding arrangements to install the ducts and air terminals.Costing is inclusive of Opening and closing for all the duct entries in civil / gypsum / any type of partition shall be under scope of HVAC vendor. Duct routing diagram can be checked in drawing prior for quoting.ressure testing of sheet metal ducts with necessary components like semi-rigid flexible ducts, fans and the measuring kit. Pressure testing shall be carried out for complete air distribution system excluding flexible ducts, diffuser box, diffusers and grilles. Pressure testing shall be carried out prior to thermal insulation and as per SMACNA standards and approval shall be obtained from PMC and consultants.
20 Gauge (1.00mm Thick - 1201mm - 2100mm) ---- etc., complete with all lead | Sqm | 1829.0 | 1829.0 | 5.0 | False | None | None | False | None | False | 9145.0 | 0 | 3092320 | 106303 | None | code41 | Supply, Installation, Testing & Commissioning of Open cell Class-1 Nitrile rubber Insulation for Duct Acoustics insulation with Ultrafresh Antimicrobial protection as per ASTM G21, ASTM G22, UL-181 and E2180 , Density 140-180Kg / m3, UL94 approved (HBF, HF 1 & HF 2) in accordance to UL 94,1996. Thermal conductivity 0.047 W / MK at 20 Deg C, Air Erosion Resistance test Confirming to ASTM Standard C 1071-05 (section 12.7).
Moisture resistant-joining tapes of 2 inches width with self adhesive to be supplied with the insulation material by the supplier.
Use Low Voc Adhesive. (Adhesive VOC level as per LEED requirement)
Note - if the adhesive is not self adhiesive type then the glue should be used with the same manufacturer.
15mm Thick. (For Duct Acoustic) ---- etc., complete with all lead | Sqm | 1298.0 | 1298.0 | 560.0 | False | None | None | False | None | False | 726880.0 | 0 | 3092321 | 106303 | None | code42 | Supply, Installation, Testing & Commissioning of Closed cell Class-O Nitrile rubber Insulation with Factroy Laminated Alu-foil for Duct thermal insulation with Ultrafresh Antimicrobial protection with both side skin/smooth surface, As per ASTM G21, ASTM G22, UL-181 and E2180. Class “O” IMO A 653 (16), FM Global, UL 94 & EPA approved,with Density 40-60kg / CUM. Temperature of -50 to 116 Deg C and As per EN12667(DIN 52612). Thermal conductivity of 0.036 W / m K @ 0 deg C. Water vapour permeability as per EN12086 (DIN 52615) , Moisture Resistance Factor = 7000. Aluminum foil tape of 75mm width should be used to seal the joints with self adhesive tape (Black Cotton Tape not acceptable).
Use Low Voc Adhesive. (Adhesive VOC level as per LEED requirement)
Note - if the adhesive is not self adhiesive type then the glue should be used with the same manufacturer.
19mm Thick. (For Exposed Ducting) ---- etc., complete with all lead | Sqm | 826.0 | 826.0 | 360.0 | False | None | None | False | None | False | 297360.0 | 0 | 3092322 | 106303 | None | code43 | Supply, Installing, testing and commissioning of closed cell Nitrile Rubber with IC CLADING (7 mil Fibre glass cloth) and Two Coats of protecticve coating.
Note :Used for Exposed Ventilaion ducting at out side of the building and terrace. ---- etc., complete with all lead | Sqm | 542.8 | 542.8 | 80.0 | False | None | None | False | None | False | 43424.0 | 0 | 3092323 | 106303 | None | code44 | Supply, Installation, Testing & Commissioning of Closed cell Class-O Nitrile rubber Insulation with Factroy Laminated Alu-foil with Ultrafresh Antimicrobial protection with both side skin/smooth surface, As per ASTM G21, ASTM G22, UL-181 and E2180. Class “O” IMO A 653 (16), FM Global, UL 94 & EPA approved,with Density 40-60kg / m3. Temperature of -50 to 116 Deg C and As per EN12667(DIN 52612). Thermal conductivity of 0.036 W / m K @ 0 deg C. Water vapour permeability as per EN12086 (DIN 52615) , Moisture Resistance Factor = 7000. Aluminum foil tape of 75mm width should be used to seal the joints with self adhesive tape (Black Cotton Tape not acceptable).
Use Low Voc Adhesive. (Adhesive VOC level as per LEED requirement)
Material shall be FM approved and preferred color shall be Black.
Note - if the adhesive is not self adhiesive type then the glue should be used with the same manufacturer.
Note: Costing is inclusive of necessary support like cup and washer with scaffolding arrangements to install the underdeck insulation.
25mm Thick (For Under Deck Insulation) ---- etc., complete with all lead | Sqm | 1062.0 | 1062.0 | 750.0 | False | None | None | False | None | False | 796500.0 | 0 | 3092324 | 106303 | None | code45 | Supply, Installation, Testing & Commissioning of Fire damper with opposed blade (Fusible link type). Fire damper as per UL 555, outer shell constructed with 1.6mm thick galvanized steel frame and the blade/Leaf with 1.6mm thick GSS and with necessary flanges for connection. The damper shall be of 90 min fire rating with Fusible Link & spring mechanism the damper shall be held open by a replaceable fusible link rated at 74 deg C.
(Area calculation : (L x B) ---- etc., complete with all lead | Sqm | 16520.0 | 16520.0 | 16.0 | False | None | None | False | None | False | 264320.0 | 0 | 3092325 | 106303 | None | code46 | Supply, Installation, Testing & Commissioning of Quadrant type Volume controle Damper (VCD). The volume control damper shall be of low leakage type with the outer shell constructed of 1.6mm thick galvanized steel frame and the blade/Leaf with 1.6mm thick GSS and with necessary flanges for connection etc.,
(Area calculation : (L x B) ---- etc., complete with all lead | Sqm | 10030.0 | 10030.0 | 20.0 | False | None | None | False | None | False | 200600.0 | 0 | 3092326 | 106303 | None | code47 | Supply, Installation, Testing & Commissioning of Back draft damper (BDD). The Back draft damper with the outer shell constructed of 1.6mm thick galvanized steel frame and the blade/Leaf with 1mm thick aluminum and with necessary flanges for connection and as per specifications.
(Area calculation : (L x B) ---- etc., complete with all lead | Sqm | 14160.0 | 14160.0 | 5.0 | False | None | None | False | None | False | 70800.0 | 0 | 3092327 | 106303 | None | code48 | Supply, Installation, Testing & Commissioning of Butterfly Damper GI Constructed Single Flap with round flange on one side and 10mm grove on other side for fixing of flexible duct with the help of band. 20G GI constructed self lubricated bronze Bushes and 1.6mm flange.
250 dia ---- etc., complete with all lead | No | 2596.0 | 2596.0 | 60.0 | False | None | None | False | None | False | 155760.0 | 0 | 3092328 | 106303 | None | code49 | Supply, Installation, Testing & Commissioning of Extruded Aluminum powder coated Exhaust air Disc valves/grille without volume control dampers for Pantry. a) Note: Colour shall be as per the False ceiling or Architect intent.
150 mm Dia ---- etc., complete with all lead | No | 1534.0 | 1534.0 | 60.0 | False | None | None | False | None | False | 92040.0 | 0 | 3092329 | 106303 | None | code50 | Supply, installation, testing and commissioning of Extruded Al. Powder coated Fresh air / Exhaust air louvers with slimline blade (3 mm nominal thickness) grille height 16 mm, blade pitch 12.5 mm and blade angle 0/15 degree deflection without damper and with end flanges.
Note: Colour shall be as per the False ceiling or Architect intent. ---- etc., complete with all lead | Sqm | 8850.0 | 8850.0 | 8.0 | False | None | None | False | None | False | 70800.0 | 0 | 3092330 | 106303 | None | code51 | Supply, Installation, Testing and Commissioning of Aluminium Collar Damper of opposed blade type aluminum extruded construction black anodized dampers.
(Used in supplay air) ---- etc., complete with all lead | Sqm | 7670.0 | 7670.0 | 7.0 | False | None | None | False | None | False | 53690.0 | 0 | 3092331 | 106303 | None | code52 | Supply, Installation, Testing & Commissioning of Condensate CPVC drain piping with insulated with 6mm Nitrile rubber insulation including elbows, connectors, U traps, Y-connections and flexible tubing for all indoor units to the nearest drain points / toilet drain / pantry drain / HVAC shaft available as per approved shop drawings or site conditions and as per directions of the Consultant and Architect. The quote should inclusive of all Hardware necessary to secure the pipes.
40 mm dia ---- etc., complete with all lead | Rmtr | 590.0 | 590.0 | 110.0 | False | None | None | False | None | False | 64900.0 | 0 | 3092332 | 106303 | None | code53 | Supply, Installation, Testing & Commissioning of Condensate CPVC drain piping with insulated with 6mm Nitrile rubber insulation including elbows, connectors, U traps, Y-connections and flexible tubing for all indoor units to the nearest drain points / toilet drain / pantry drain / HVAC shaft available as per approved shop drawings or site conditions and as per directions of the Consultant and Architect. The quote should inclusive of all Hardware necessary to secure the pipes.
32 mm dia ---- etc., complete with all lead | Rmtr | 531.0 | 531.0 | 80.0 | False | None | None | False | None | False | 42480.0 | 0 | 3092333 | 106303 | None | code54 | Supply, Installation, Testing & Commissioning of Condensate CPVC drain piping with insulated with 6mm Nitrile rubber insulation including elbows, connectors, U traps, Y-connections and flexible tubing for all indoor units to the nearest drain points / toilet drain / pantry drain / HVAC shaft available as per approved shop drawings or site conditions and as per directions of the Consultant and Architect. The quote should inclusive of all Hardware necessary to secure the pipes.
25 mm dia ---- etc., complete with all lead | Rmtr | 413.0 | 413.0 | 810.0 | False | None | None | False | None | False | 334530.0 | 0 | 3092334 | 106303 | None | code55 | Supply, Installation, Testing & Commissioning of Drain Pumps for CHW/VRV/VRF/DX Type Hi-Wall Units and Ceiling Mounted Units.
Mini Blanc Pumps (External) for Hi-Wall units. (Max. flow 12L/h & Head is 10Met) ---- etc., complete with all lead | No | 10030.0 | 10030.0 | 47.0 | False | None | None | False | None | False | 471410.0 | 0 | 3092335 | 106303 | None | code56 | Supply, Installation, Testing & Commissioning of Drain Pumps for CHW/VRV/VRF/DX Type Hi-Wall Units and Ceiling Mounted Units.
Mini Tank Pump (Less then 5.0 TR CSU/FCU) - (Max. flow 35L/h & Head is 15Met) ---- etc., complete with all lead | No | 11269.0 | 11269.0 | 1.0 | False | None | None | False | None | False | 11269.0 | 0 | 3092336 | 106303 | None | code57 | Supply, Installation, Testing & Commissioning of Drain Pumps for CHW/VRV/VRF/DX Type Hi-Wall Units and Ceiling Mounted Units.
Max Hi-Flow (Above 5.0 TR CSU/FCU) - (Max. flow 550L/h & Head is 5Met) ---- etc., complete with all lead | No | 14160.0 | 14160.0 | 15.0 | False | None | None | False | None | False | 212400.0 | 0 | 3092337 | 106303 | None | code58 | Supply, Installation, Testing & Commissioning of Duct type Strip heater (For Customized AHU's) with nessacery electrical wiring and connection. Incoming power supply from respactive Starter panel. (Used in Winter season to achiev the room Temp)
Heater bank & Duct befer and after the Heater bank should be panted in RED for 150mm on either side of the Heater bank.
1.5 Kw ---- etc., complete with all lead | No | 8850.0 | 8850.0 | 8.0 | False | None | None | False | None | False | 70800.0 | 0 | 3092338 | 106303 | None | code59 | Supply, Installation, Testing & Commissioning of Duct type Strip heater (For Customized AHU's) with nessacery electrical wiring and connection. Incoming power supply from respactive Starter panel. (Used in Winter season to achiev the room Temp)
Heater bank & Duct befer and after the Heater bank should be panted in RED for 150mm on either side of the Heater bank.
3.0 Kw ---- etc., complete with all lead | No | 12980.0 | 12980.0 | 28.0 | False | None | None | False | None | False | 363440.0 | 0 | 3092339 | 106303 | None | code60 | Supply, Installation, Testing & Commissioning of Magnehelic Differential Pressure Gages (IP-67 enclosure) to Indicate Positive, Negative or Differential, Accurate within 1%. Note: Pressures must be less than 35 psi.Mounting Orientation:Diaphragm in vertical position. Consult factory for other position orientations.
Costing is inclusive of with necessary fittings and Pitot Tube and etc.. AHU/CSU Filter Section ---- etc., complete with all lead | No | 10620.0 | 10620.0 | 11.0 | False | None | None | False | None | False | 116820.0 | 0 | 3092340 | 106303 | None | code61 | Supply, Installation, Testing & Commissioning of Duct Type Temperature & RH Sensors (IP-40 enclosure) (Immersion depth : 230 mm) with all mounting accessories to measure the Return Air temperatures. (Temperature range : -0C to 55C & R.H. range 10% to 90%) Note : Used for AHU's, CSU's FCU's & Cassette units. ---- etc., complete with all lead | No | 8850.0 | 8850.0 | 11.0 | False | None | None | False | None | False | 97350.0 | 0 | 3092341 | 106303 | None | code62 | Supply, Installation, Testing & Commissioning of Room Type Temperature & RH Digital Sensors (Thermostats) with all mounting accessories to measure the critical Room air temperatures. (Temperature range : -20C to 60C & R.H. range 0% to 99%) ---- etc., complete with all lead | No | 10030.0 | 10030.0 | 11.0 | False | None | None | False | None | False | 110330.0 | 0 | 3092342 | 106303 | None | code63 | STARTER FOR VENTILATION EQUIPMENT (NON VFD)
Designing, Fabrication, Supply, Installation, Testing & Commissioning of Cubical type Ventilation Equipment DOL, Star / Delta Starters without VFD Provision with minimum IP-54 rating. (Additional Enclosures not acceptable)
Alpha numeric Graphical Display with inbuilt energy meter, ammeter, voltmeter etc. and shall be capable of displaying any 5 parameters simultaneously.
Panel should have following :
1)The incomer of the starter panel should be MCCB with suitable equipment rating. 2) Interlock between - Ventilation Equipment, Fire damper, actuator... etc 3) On / Off Trip & RYB indication. 4) Auto / Manual operation with timer controle. 5) Single phase preventore for protection.
6) Selection of the compnents as per Type-2 coordination chart. 7) Starter panel with moter protection circute breaker. 8) Starter should compactable for BMS. 9) Controle & power cable should be FRLS. 10) Enclosure with CRCA 2mm Powder coated as per site condetion. 11) Ventilation Equipment Starter panel should be constructed with IP-54 rating. 12) Emmergency push button for all the starters. (EPB) 13) Starter panel with Energy meter with RS485 port provision.
Note : During Fire Emergency operation, these panels should receive the Fire Trip signal from the emergency stop push button from the different location, and should stop the respective HVAC Equipment.
5.5 kW (STAR/DELTA) ---- etc., complete with all lead | No | 53100.0 | 53100.0 | 1.0 | False | None | None | False | None | False | 53100.0 | 0 | 3092343 | 106303 | None | code64 | STARTER FOR VENTILATION EQUIPMENT (NON VFD)
Designing, Fabrication, Supply, Installation, Testing & Commissioning of Cubical type Ventilation Equipment DOL, Star / Delta Starters without VFD Provision with minimum IP-54 rating. (Additional Enclosures not acceptable)
Alpha numeric Graphical Display with inbuilt energy meter, ammeter, voltmeter etc. and shall be capable of displaying any 5 parameters simultaneously.
Panel should have following :
1)The incomer of the starter panel should be MCCB with suitable equipment rating. 2) Interlock between - Ventilation Equipment, Fire damper, actuator... etc 3) On / Off Trip & RYB indication. 4) Auto / Manual operation with timer controle. 5) Single phase preventore for protection.
6) Selection of the compnents as per Type-2 coordination chart. 7) Starter panel with moter protection circute breaker. 8) Starter should compactable for BMS. 9) Controle & power cable should be FRLS. 10) Enclosure with CRCA 2mm Powder coated as per site condetion. 11) Ventilation Equipment Starter panel should be constructed with IP-54 rating. 12) Emmergency push button for all the starters. (EPB) 13) Starter panel with Energy meter with RS485 port provision.
Note : During Fire Emergency operation, these panels should receive the Fire Trip signal from the emergency stop push button from the different location, and should stop the respective HVAC Equipment
9.3 kW (STAR/DELTA) ---- etc., complete with all lead | No | 70800.0 | 70800.0 | 1.0 | False | None | None | False | None | False | 70800.0 | 0 | 3092344 | 106303 | None | code65 | Supply, installation, testing and commissioning of Electrical Power & Controle cabling for AC units, Ventilation & Pressurization fans units.
Note :
a) Costing is inclusive of necessary supports & supporting rods, saddles at 1m interval.
b) Electrical Power cabling quantity (Rmtr) to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.
c) Actual measurement of Electrical Power cabling quantity (Rmtr) should be taken as per site condition only.
3.0 Core x 2.5 Sqmm - For AHU/CSU/Ventilation units units. (Can be used up to 3.7 Kw / 3Phase)
Flexible Cross-linked polyethylene (XLPE) insulated Armoured copper cables (FRLS) Control & Power cable to connect HVAC or Electrical starter panel to respective HVAC equipment. ---- etc., complete with all lead | Rmtr | 472.0 | 472.0 | 235.0 | False | None | None | False | None | False | 110920.0 | 0 | 3092345 | 106303 | None | code66 | Supply, installation, testing and commissioning of Electrical Power & Controle cabling for AC units, Ventilation & Pressurization fans units.
Note :
a) Costing is inclusive of necessary supports & supporting rods, saddles at 1m interval.
b) Electrical Power cabling quantity (Rmtr) to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.
c) Actual measurement of Electrical Power cabling quantity (Rmtr) should be taken as per site condition only.
3.0 Core x 4.0 Sqmm - For AHU/CSU/Ventilation units units.
(Can be used up to 7.5 Kw / 3Phase)
Flexible Cross-linked polyethylene (XLPE) insulated Armoured copper cables (FRLS) Control & Power cable to connect HVAC or Electrical starter panel to respective HVAC equipment. ---- etc., complete with all lead | Rmtr | 660.8 | 660.8 | 30.0 | False | None | None | False | None | False | 19824.0 | 0 | 3092346 | 106303 | None | code67 | Supply, installation, testing and commissioning of Electrical Power & Controle cabling for AC units, Ventilation & Pressurization fans units.
Note :
a) Costing is inclusive of necessary supports & supporting rods, saddles at 1m interval.
b) Electrical Power cabling quantity (Rmtr) to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.
c) Actual measurement of Electrical Power cabling quantity (Rmtr) should be taken as per site condition only.
3.0 Core x 6.0 Sqmm - For AHU/CSU/Ventilation units units.
(Can be used up to 11.0 Kw / 3Phase)
Flexible Cross-linked polyethylene (XLPE) insulated Armoured copper cables (FRLS) Control & Power cable to connect HVAC or Electrical starter panel to respective HVAC equipment. ---- etc., complete with all lead | Rmtr | 767.0 | 767.0 | 30.0 | False | None | None | False | None | False | 23010.0 | 0 | 3092347 | 106303 | None | code68 | AHU's RECYCLE SYSTEM FOR OT AREA AS PER NABH NORMS
Supply, installation, testing and commissioning of Floor Mounted Air Handling Units (AHU) of GSS powder coated sheet metal cabinet type Double skin Recirculatory type 40-45 mm thick,Thermal break,modular construction.Air handling units shall be complete with Backward curved blower having capacity of 3500 t0 4000 cfm (Minimum 25 to 35 ACPH ) with 125 mm capacity, 3.75kw TEFC motor,fan motor drive filter section with 10 microns pre filter,3 microns fine filters, DX coil 6 row section of copper coil with aluminium fins,Mist eleminator, inlet and outlet volume control dampers and bypass dampers with access doors and accessories including 10% Fresh air with module with console type and grill, 20 Microns Fresh air filter. 10% Bleed module with hepa filter,damper and grille, View glass, View lamp, limit switch for door & Pressure port for filter sections & provision to fix pressure port to measure the pressure drop across the filter, (EFF1 Motor) coil should be 5. 5 TR x 2 circute with all concted accessories. ---- etc., complete with all lead | No | 442500.0 | 442500.0 | 4.0 | False | None | None | False | None | False | 1770000.0 | 0 | 3092348 | 106303 | None | code69 | Supply, installation, testing and commissioning of 5.5 TR Air cooled out door condensing units comprising of semi -hermetic / hermetic reciprocating/scrool compressors with matching air cooled condenser suitable for 3500 to 4000 CFM AHU provided with necessary controls.like Thermostart , Draier with MS painted stand. ---- etc., complete with all lead | No | 177000.0 | 177000.0 | 8.0 | False | None | None | False | None | False | 1416000.0 | 0 | 3092349 | 106303 | None | code70 | Supply, installation, testing and commissioning of Stainless steel 304 grade Plenum LAMINAR FLOW - Plan air Ceiling mounted system with unidirectional airflow,(Air flow velocity of 25 to 35 FPM) Plenum unit, Holding structure & Top plenum are conforming to DIN 4799 / EU14 (Mini pleate HEPA filter) standards for the air distribution system complete with provision for 6 Nos.
(Size 1220mmX610mmX90mm thick) HEPA Filters (efficiency 99.97% down to 0.3 micron ), 4000 cfm. The Plenum size is 1800 x 2400mm. The Diffuser is made out of SS 304 Grade material for laminar of filtered air. The complete unit will have factory prepared fine sealing system. It will be perfectly seamless. It will be made out of SS 304 Sheet of required thickness With perforated SS 304 sheet with etc., complete. ---- etc., complete with all lead | No | 354000.0 | 354000.0 | 4.0 | False | None | None | False | None | False | 1416000.0 | 0 | 3092350 | 106303 | None | code71 | Supply, installation, testing and commissioning of SS 304 grade return air grill. The cut out for return air grill size in panel is 600mmX450mm. The cost includes cost of material, labour charges for fixing etc complete. ---- etc., complete with all lead | No | 3540.0 | 3540.0 | 16.0 | False | None | None | False | None | False | 56640.0 | 0 | 3092351 | 106303 | None | code72 | Supply, installation, testing and commissioning of Return air riser made out of SS 304 grade with 18 SWG in the clean room area of 1000 CFM and provision for return air collar damper anf grill with all concted accessories. ---- etc., complete with all lead | No | 14750.0 | 14750.0 | 16.0 | False | None | None | False | None | False | 236000.0 | 0 | 3092352 | 106303 | None | code73 | Supply, installation, testing and commissioning of Providing and making trap door of size 600 x 600mm in the ceiling panel by cutting. The required frame work shall be made by using Aluminium sections. The cost includes cost of material, labour charges for fixing etc complete. ---- etc., complete with all lead | No | 6254.0 | 6254.0 | 4.0 | False | None | None | False | None | False | 25016.0 | 0 | 3092353 | 106303 | None | code74 | Supply, Installation, Testing & Commissioning of Al. ducting including the supports,selicon sealent with painted MS angle flanges.
22 guage ---- etc., complete with all lead | Sqm | 1652.0 | 1652.0 | 690.0 | False | None | None | False | None | False | 1139880.0 | 0 | 3092354 | 106303 | None | code75 | Supply, installation, testing and commissioning of Polishield covering with two coats paint for exposed duct. ---- etc., complete with all lead | Sqm | 354.0 | 354.0 | 280.0 | False | None | None | False | None | False | 99120.0 | 0 | 3092355 | 106303 | None | code76 | Supply, installation, testing and commissioning of 300 dia Insulated flexible connection for grille module & return air raiser. ---- etc., complete with all lead | Sqm | 885.0 | 885.0 | 80.0 | False | None | None | False | None | False | 70800.0 | 0 | 3092356 | 106303 | None | code77 | Supply, installation, testing and commissioning of Fire retardant flexible connections for AHU supply & return air mouth. ---- etc., complete with all lead | Nos | 8260.0 | 8260.0 | 8.0 | False | None | None | False | None | False | 66080.0 | 0 | 3092357 | 106303 | None | code78 | Supply, installation, testing and commissioning of Ele.controll panel inter lock with AHUs and 5.5 TR 2 nos condenser unit with TEMP & RH Controller For OT AHU. ---- etc., complete with all lead | Set | 94400.0 | 94400.0 | 4.0 | False | None | None | False | None | False | 377600.0 | 0 | 3092358 | 106303 | None | code79 | Supply, installation, testing and commissioning of 4 Kw Ele. Heater with RH controller to controll humidity of 50 to 60%. ---- etc., complete with all lead | Set | 13570.0 | 13570.0 | 4.0 | False | None | None | False | None | False | 54280.0 | 0 | 3092359 | 106303 | None | code80 | Supply, installation, testing and commissioning of DP Gauge range 0 to 6mm wg for OT room to monitoring positive pressure. ---- etc., complete with all lead | No | 8850.0 | 8850.0 | 4.0 | False | None | None | False | None | False | 35400.0 | 0 | 3092360 | 106303 | None | code81 | Supply, Installation, Testing & Commissioning of DP Gauge range 0 to 50mm wg for AHU & EAU pre & fine filter section to monitoring pressure drop in the filters. ---- etc., complete with all lead | No | 11800.0 | 11800.0 | 8.0 | False | None | None | False | None | False | 94400.0 | 0 | 3092361 | 106303 | None | code82 | Note: 2 SET of DOCUMENTS & VALIDATION AT REST AS PER ISO-14644 and NABH standard to be Submitted.
Note: Below listed items are part of HVAC Contractor scope of works -
Design Qualification, Installation Qualification, Operational Qualification, Performance Qualification.
a) Air velocity test.
b) Air changes test.
c) Air qty.check test.
d) Temp. & RH test.
e) DOP test for Hepa filter.
f) Partical count test. (Class 100, ISO - 5in the termial)
g) Air flow pattern test.
h) Recovery test.
i) Majot materil test certificates. ---- etc., complete with all lead | Lot | 59000.0 | 59000.0 | 4.0 | False | None | None | False | None | False | 236000.0 | 0 |
| 1710501218000 | 0 | None | None | Buildings | Fire Fighting works | 44119757.29 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3092362 | 106304 | None | code01 | Supply, erection, testing & commissioning of electrical motor driven end suction back pull out centrifugal pump capable of delivering, adequate LPM at required head. when running at 2900 rpm directly coupled to TEFC electrical motor of adequate HP to operate on 400/440V 3phase, 50cycles AC supply with required foundation for pump, a terminal box suitable for reception, common bed plate with necessary antivibration pads, necessary foundation bolts and accessories, neoprine gaskets (16kg/sq.cm) Control panel is excluded. Required GA drawing for the pump/foundation shall be submitted by the contractor. 2280 lpm@70 m head ---- etc., complete with all lead | No | 369930.0 | 369930.0 | 2.0 | False | None | None | False | None | False | 739860.0 | 0 | 3092363 | 106304 | None | code02 | Supply, installation, testing & commissioning of diesel engine driven pump, horizontal mounted, Horizontal spilt case centrifugal single stage pump, capable of delivering required flow at required head when running at 1800 RPM with adequate BHP automatic diesel engine driven pump set having the residential silencer system and other accessories like fueltank, ecessary radiator cooling system, flanges, neoprene gaskets (16.0kg/sqcm), 200 litres fuel storage tank with piping, valves as per detailed specification and two separate starting mechanisms (automatic starting by battery power, electric starting motor as well as manual starting by electric start motor) common bed plate with anti vibration pads, necessary foundation, foundation bolts etc., 2280 lpm@70 m head ---- etc., complete with all lead | No | 721688.0 | 721688.0 | 2.0 | False | None | None | False | None | False | 1443376.0 | 0 | 3092364 | 106304 | None | code03 | Supply, Installation, testing and commisioning electrically driven jockey pump of capacity 180.0Lpm at required head end suction type bronze impeller pump coupled to electrical driven motor with suitable HP with all the necessary accessories, operating on 3Ph 50Hz, 400/440V AC supply including foundation, foundation bolts, antivibration pad, etc. complete. Including cost of materials, labour, usage charges of machinery complete as pers pecifications. Control panle is excluded. Required GA drawing for the pump/ foundation shall be submitted by the contractor. 180 lpm@70 m head ---- etc., complete with all lead | No | 110330.0 | 110330.0 | 2.0 | False | None | None | False | None | False | 220660.0 | 0 | 3092365 | 106304 | None | code04 | Supplying, Installing testing & commissioning approved make Centrifugal pump end suction type coupled to Electric motor of suitable HP, fitted on a commonbase frame and rated for Fire duty. The quated price shall aslo include 2 Nos. Pressure guages fitted on suction & delivery sides of the pump. The pumps shall run on 400/440V 3 ph. 50 Hz electric supply. Duty of pumps: 900 Lpm @ 35.0m Head. Control panel shall be as specified in item no, 87, including cost of materials, labour, usage charges of machinery complete as per specifications.(FOR WATER CURTAIN) ---- etc., complete with all lead | No | 109386.0 | 109386.0 | 1.0 | False | None | None | False | None | False | 109386.0 | 0 | 3092366 | 106304 | None | code05 | Supplying Installing testing and commissiong COMMON Control panel for fire fighting system consiting of electrical motor driven 60HP Main fire pump, Diesel engine driven pump 60 BHP & Jockey pump 7.5HP Supply, erection, testing and commissioning of Fire Fighting panel cubicle type made out of 14/16Swg MS CRCA sheet which is derusted, degreased, phosphated and passivated with angle iron skeleton or sheet folded construction. The panel tobe dust and vermin proof type and with powder coated paint after suitable seven tank pretreatment. The panel will have individual compartments for incoming and out going feeders made out of cold rolled sheet and doors fitted with Neoprene gaskets and fasteners. The switch boards are tobe tested as per IS 8623-1977 specifications. Bus bars are tobe of high conductivity Aluminium Alloy E91E IS 5082 specification. The panel shall have both bottom & top cable entry provisions and panel shall be mounted on Pedestal of 300 mm height. Incoming feeder for 250A TPN MCCB with 250Amps. TPN Al. Busbars with color coded heat shrinkable PVC sleeves, RYB indicating lamps with individual MCB control. Suitable Mulit Fuction meter with CTs OUTGOINGFeeder for 1Noof main pump:-1 Nos. 160A TP MCCB with 60 HP Star delta starter with overload relay, single phase preventer and indicating lamps with ON / OFF push buttons. 1 No Automanual selector switch. Feeder for 1 No of Jockey pump:-1 No 63A TP MCCB with 7.5HP star delta starter with overload relay, single phase preventer and indicating lamp swith ON / OFF push buttons. 1 No Automanual selector switch. Feeder for 1 No DIESEL ENGINE MAIN PUMP:- a) 20Amps DP MCB-4Nos. b) Battery charger with transformer with rectifier resistance DC ammeter, DC voltmeter, T Trickle / booster off selector switch- 2 Nos. c) 1 set of indicating lamps for the following: 1. phase indication 2. battery charger on 3. overload relay 4. DC supply on 5. control switch on 6. Engine fails to start 7. Pump on 8. Low oil pressure 9. High water temperature 10. Automanual selector switch d) 1 sets of push button stations for the following: 1. Engine Start 2. EngineStop 3. Engine-hooter ACK 4. Engine-fault resete) Selector switches (Engine control, mode selector)-1 No f) Auxiliary relays / contactors / timer for sequence operating for starting and stopping of the engine-1 set .g) Hooter for audio alarm (Industrial type) 1 No ---- etc., complete with all lead | Unit | 360844.0 | 360844.0 | 2.0 | False | None | None | False | None | False | 721688.0 | 0 | 3092367 | 106304 | None | code06 | Supplying, installing, testing and commissioning of PN 16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc., complete etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work. 200 mm dia CI Butterfly valaves ---- etc., complete with all lead | Nos | 20768.0 | 20768.0 | 8.0 | False | None | None | False | None | False | 166144.0 | 0 | 3092368 | 106304 | None | code07 | Supplying, installing, testing and commissioning of PN 16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc., complete etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work. 150 mm dia CI Butterfly valaves ---- etc., complete with all lead | Nos | 16225.0 | 16225.0 | 12.0 | False | None | None | False | None | False | 194700.0 | 0 | 3092369 | 106304 | None | code08 | Supplying, installing, testing and commissioning of PN 16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc., complete etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work. 100 mm dia CI Butterfly valaves ---- etc., complete with all lead | Nos | 11682.0 | 11682.0 | 10.0 | False | None | None | False | None | False | 116820.0 | 0 | 3092370 | 106304 | None | code09 | Supplying, installing, testing and commissioning of PN 16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc., complete etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work. 80 mm dia CI Butterfly valaves ---- etc., complete with all lead | Nos | 9086.0 | 9086.0 | 2.0 | False | None | None | False | None | False | 18172.0 | 0 | 3092371 | 106304 | None | code10 | Supplying installing, testing and commissioning of PN 16 CI Non Return Valve confirming to IS 13039 with necessary bolts and nuts etc,. complete includes cost of all materials labour charges with all lead lift loading and unloading transportation etc complete. etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work. 200 mm Dia CI Non return valve ---- etc., complete with all lead | Nos | 18172.0 | 18172.0 | 2.0 | False | None | None | False | None | False | 36344.0 | 0 | 3092372 | 106304 | None | code11 | Supplying installing, testing and commissioning of PN 16 CI Non Return Valve confirming to IS 13039 with necessary bolts and nuts etc,. complete includes cost of all materials labour charges with all lead lift loading and unloading transportation etc complete. etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work. 150 mm Dia CI Non return valve ---- etc., complete with all lead | Nos | 16225.0 | 16225.0 | 4.0 | False | None | None | False | None | False | 64900.0 | 0 | 3092373 | 106304 | None | code12 | Supplying installing, testing and commissioning of PN 16 CI Non Return Valve confirming to IS 13039 with necessary bolts and nuts etc,. complete includes cost of all materials labour charges with all lead lift loading and unloading transportation etc complete. etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work. 100 mm Dia CI Non return valve ---- etc., complete with all lead | Nos | 9241.76 | 9241.76 | 8.0 | False | None | None | False | None | False | 73934.08 | 0 | 3092374 | 106304 | None | code13 | Supplying installing, testing and commissioning of PN 16 CI Non Return Valve confirming to IS 13039 with necessary bolts and nuts etc,. complete includes cost of all materials labour charges with all lead lift loading and unloading transportation etc complete. etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work. 80 mm Dia CI Non return valve ---- etc., complete with all lead | Nos | 7139.0 | 7139.0 | 4.0 | False | None | None | False | None | False | 28556.0 | 0 | 3092375 | 106304 | None | code14 | supply and installing testing and commissioning of CI Y stainer confirming to IS standard with necessary bolts and nuts complete includes cost of all materials labour charges with all lead lift loading and unloading transportation etc complete.- complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work. 200 mm Dia CI Y Stariner ---- etc., complete with all lead | Nos | 31801.0 | 31801.0 | 4.0 | False | None | None | False | None | False | 127204.0 | 0 | 3092376 | 106304 | None | code15 | supply and installing testing and commissioning of CI Y stainer confirming to IS standard with necessary bolts and nuts complete includes cost of all materials labour charges with all lead lift loading and unloading transportation etc complete.- complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work. 150 mm Dia CI Y Stariner ---- etc., complete with all lead | Nos | 24077.9 | 24077.9 | 4.0 | False | None | None | False | None | False | 96311.6 | 0 | 3092377 | 106304 | None | code16 | supply and installing testing and commissioning of CI Y stainer confirming to IS standard with necessary bolts and nuts complete includes cost of all materials labour charges with all lead lift loading and unloading transportation etc complete.- complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work. 100 mm Dia CI Y Stariner ---- etc., complete with all lead | Nos | 16082.22 | 16082.22 | 4.0 | False | None | None | False | None | False | 64328.88 | 0 | 3092378 | 106304 | None | code17 | Pressure Switch including Isolation Valve and forged siphon Tube including with all accssories as per IS :Spec.etc.,complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work ---- etc., complete with all lead | Nos | 2531.1 | 2531.1 | 9.0 | False | None | None | False | None | False | 22779.9 | 0 | 3092379 | 106304 | None | code18 | Supplying and fixing air vessel made of 250 mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain
arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade
as required. ---- etc., complete with all lead | No | 38940.0 | 38940.0 | 2.0 | False | None | None | False | None | False | 77880.0 | 0 | 3092380 | 106304 | None | code19 | Pressure guage of 150mm dia including Isolation Valve and forged siphonTube including with all accssories as per IS :Spec.etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work ---- etc., complete with all lead | No | 3764.2 | 3764.2 | 6.0 | False | None | None | False | None | False | 22585.2 | 0 | 3092381 | 106304 | None | code20 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all lead | Kg | 190.81 | 190.81 | 600.0 | False | None | None | False | None | False | 114486.0 | 0 | 3092382 | 106304 | None | code21 | FIREFIGHTING ELECTRICALSupply of the Following XLPE armoured cable 1100 V Grade with ISI mark stranded / solid, aluminimum conductor complete with crimping type Lugs and Glands etc completed. 3.5 Core 95.00 Sq.mm.Main Panel Electrical Pump ---- etc., complete with all lead | Km | 667223.92 | 667223.92 | 0.18 | False | None | None | False | None | False | 120100.3056 | 0 | 3092383 | 106304 | None | code22 | FIREFIGHTING ELECTRICALSupply of the Following XLPE armoured cable 1100 V Grade with ISI mark stranded / solid, aluminimum conductor complete with crimping type Lugs and Glands etc completed. 4.0 Core 16.00 Sq.mm.Main Panel to Jockey ---- etc., complete with all lead | Km | 238107.72 | 238107.72 | 0.4 | False | None | None | False | None | False | 95243.088 | 0 | 3092384 | 106304 | None | code23 | Supply and installation of 12 Core x 2.5Sqmm For Main Panel to DG ---- etc., complete with all lead | Mtr | 472.0 | 472.0 | 100.0 | False | None | None | False | None | False | 47200.0 | 0 | 3092385 | 106304 | None | code24 | 3 Core x 1.5Sqmm for Pressure Switch ---- etc., complete with all lead | Mtr | 123.31 | 123.31 | 140.0 | False | None | None | False | None | False | 17263.4 | 0 | 3092386 | 106304 | None | code25 | Supplying, installation, testing & commissioning of 12V ..AH batteries in poly propylene container for D.G. sets. Low maintenance batteries, plate type. (150 AH capacity) ---- etc., complete with all lead | Nos | 36586.73 | 36586.73 | 2.0 | False | None | None | False | None | False | 73173.46 | 0 | 3092387 | 106304 | None | code26 | Supplying and installing following size of perforated painted with powder cating m.s. cable trays with perforation not more than 17.5% in convenient sections, joined with connectors, suspended from the ceiling with m.s. suspenders including bolts & nuts, painting suspendrrs etc as required. Size: 300mm width x50mm depth x1.6mm thickness ---- etc., complete with all lead | Mtr | 1008.55 | 1008.55 | 200.0 | False | None | None | False | None | False | 201710.0 | 0 | 3092388 | 106304 | None | code27 | GI/Copper strips for grounding connections, using necessary fixing
materials as required. (25 x 3 mm GI strip) ---- etc., complete with all lead | Mtr | 106.44 | 106.44 | 250.0 | False | None | None | False | None | False | 26610.0 | 0 | 3092389 | 106304 | None | code28 | Supply, Installation testing and commissioning of approved make heavy quantity (Class C) confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. 200 mm dia ---- etc., complete with all lead | m | 5581.4 | 5581.4 | 90.0 | False | None | None | False | None | False | 502326.0 | 0 | 3092390 | 106304 | None | code29 | Supply, Installation testing and commissioning of approved make heavy quantity (Class C) confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. 150 mm dia ---- etc., complete with all lead | m | 5062.2 | 5062.2 | 975.0 | False | None | None | False | None | False | 4935645.0 | 0 | 3092391 | 106304 | None | code30 | Supply, Installation testing and commissioning of approved make heavy quantity (Class C) confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. 100 mm dia ---- etc., complete with all lead | m | 3699.3 | 3699.3 | 940.0 | False | None | None | False | None | False | 3477342.0 | 0 | 3092392 | 106304 | None | code31 | Supply, Installation testing and commissioning of approved make heavy quantity (Class C) confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. 80 mm dia ---- etc., complete with all lead | m | 2985.4 | 2985.4 | 665.0 | False | None | None | False | None | False | 1985291.0 | 0 | 3092393 | 106304 | None | code32 | Supply, Installation testing and commissioning of approved make heavy quantity (Class C) confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. 65 mm dia ---- etc., complete with all lead | m | 2206.6 | 2206.6 | 505.0 | False | None | None | False | None | False | 1114333.0 | 0 | 3092394 | 106304 | None | code33 | Supply, Installation testing and commissioning of approved make heavy quantity (Class C) confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. 50 mm dia ---- etc., complete with all lead | m | 1687.4 | 1687.4 | 920.0 | False | None | None | False | None | False | 1552408.0 | 0 | 3092395 | 106304 | None | code34 | Supply, Installation testing and commissioning of approved make heavy quantity (Class C) confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. 40 mm dia ---- etc., complete with all lead | m | 1362.9 | 1362.9 | 855.0 | False | None | None | False | None | False | 1165279.5 | 0 | 3092396 | 106304 | None | code35 | Supply, Installation testing and commissioning of approved make heavy quantity (Class C) confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. 32 mm dia ---- etc., complete with all lead | m | 1038.4 | 1038.4 | 865.0 | False | None | None | False | None | False | 898216.0 | 0 | 3092397 | 106304 | None | code36 | Supply, Installation testing and commissioning of approved make heavy quantity (Class C) confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. 25 mm dia ---- etc., complete with all lead | m | 908.6 | 908.6 | 6845.0 | False | None | None | False | None | False | 6219367.0 | 0 | 3092398 | 106304 | None | code37 | Wraping and Galing of U/G pipe line work includes one coat of anti corrossion paint (Black) and two coats of Bituminous cloth. including cost of materials, labour, usage charges of machinery complete as per specifications. - 150 mm dia ---- etc., complete with all lead | m | 519.2 | 519.2 | 900.0 | False | None | None | False | None | False | 467280.0 | 0 | 3092399 | 106304 | None | code38 | Wraping and Galing of U/G pipe line work includes one coat of anti corrossion paint (Black) and two coats of Bituminous cloth. including cost of materials, labour, usage charges of machinery complete as per specifications. - 100 mm dia ---- etc., complete with all lead | m | 324.5 | 324.5 | 150.0 | False | None | None | False | None | False | 48675.0 | 0 | 3092400 | 106304 | None | code39 | Wraping and Galing of U/G pipe line work includes one coat of anti corrossion paint (Black) and two coats of Bituminous cloth. including cost of materials, labour, usage charges of machinery complete as per specifications. - 80 mm dia ---- etc., complete with all lead | m | 259.6 | 259.6 | 230.0 | False | None | None | False | None | False | 59708.0 | 0 | 3092401 | 106304 | None | code40 | Supplying, installing , testing and commissioning approved make CI butterfly valves of 100mm diameter confirming to IS 13039 with necessary nuts & bolts etc., complete ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work ---- etc., complete with all lead | Nos | 11682.0 | 11682.0 | 40.0 | False | None | None | False | None | False | 467280.0 | 0 | 3092402 | 106304 | None | code41 | Supplying, installing , testing and commissioning approved make CI butterfly valves of 50mm diameter confirming to IS 13039 with necessary nuts & bolts etc., complete ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work ---- etc., complete with all lead | Nos | 5841.0 | 5841.0 | 26.0 | False | None | None | False | None | False | 151866.0 | 0 | 3092403 | 106304 | None | code42 | Providing & fixing Flow Switch in following sizes M.S. pipe including connnection etc as required.100mm dia ---- etc., complete with all lead | Each | 9753.17 | 9753.17 | 15.0 | False | None | None | False | None | False | 146297.55 | 0 | 3092404 | 106304 | None | code43 | Supplying Installing, testing and commissioning of hydraulically operated sprinkler Gong Valve with water meter gong bell and trims as required, pressure gauges drain Valve, ball Valves check valve, strainer etc. including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all lead | Each | 90860.0 | 90860.0 | 2.0 | False | None | None | False | None | False | 181720.0 | 0 | 3092405 | 106304 | None | code44 | Supplying Installing, testing and commissioning of 150mm dia 4way Fire brigade inlet connection with Non retrn valve of 4nos. 63mm dia. Including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all lead | No | 49324.0 | 49324.0 | 2.0 | False | None | None | False | None | False | 98648.0 | 0 | 3092406 | 106304 | None | code45 | Supplying Installing, testing and commissioning of 100mm dia 2 way Fire brigade inlet connection of 2 nos. 63 mm dia. including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all lead | No | 42834.0 | 42834.0 | 2.0 | False | None | None | False | None | False | 85668.0 | 0 | 3092407 | 106304 | None | code46 | Stainless steel braide flexible pipe (hose) for dropping sprinklers below false ceiling, pipe shall be 16bar pressure rating and 1500mm long 25mm dia with union / reducer collar, clamps etc. as required. ---- etc., complete with all lead | No | 3245.0 | 3245.0 | 170.0 | False | None | None | False | None | False | 551650.0 | 0 | 3092408 | 106304 | None | code47 | Supplying Installing, testing and commissioning of Ceiling Mounted powder coated Surface Finishing Mild Steel Rosette Plate including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all lead | No | 142.78 | 142.78 | 275.0 | False | None | None | False | None | False | 39264.5 | 0 | 3092409 | 106304 | None | code48 | INTERNAL FIRE HYDRANT SYSTEM Supplying Installing, testing and commissioning of 63mm dia Single headed Gun mental Hydrant Valve with flanged inlet, stop valve,spindle and cast iron hand wheel. It has a female instantaneous outlet with Blank Cap and is Hydrostatically tested to 21 Kgf/cm2 pressure having a flow rate of 900 LPM at 7 Kgf/cm 2 of pressure with blank cap and wheel as per IS 5290 etc. complete including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all lead | No | 13629.0 | 13629.0 | 26.0 | False | None | None | False | None | False | 354354.0 | 0 | 3092410 | 106304 | None | code49 | Supplying Installing, testing and commissioning of Reinforced Rubber Lined 2nos .RRL Fire hose of 63mm dia 15m length as per IS 8423 binded with one set of male and Female lnstantainious Gun metal coupling as per IS 903 complete including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all lead | Each | 6490.0 | 6490.0 | 52.0 | False | None | None | False | None | False | 337480.0 | 0 | 3092411 | 106304 | None | code50 | Supplying Installing, testing and commissioning of Gun metal Branch pipe size of 63mm dia x19mm dia as per IS 903 complete including cost of materials, labour,usage charges of machinery complete as per specifications. ---- etc., complete with all lead | Each | 5841.0 | 5841.0 | 26.0 | False | None | None | False | None | False | 151866.0 | 0 | 3092412 | 106304 | None | code51 | Supplying Installing, testing and commissioning of Hose cabinet made out of 18 gauge M.S.sheet with double glass door with lacing arrangement and painted with two coats of Fire red Enamel paint at outer ise of the Box and two coats of white enamel paint at inner side of the box is to accomodated 2 Nos. of Fire hose box size
20x24x10 complete including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all lead | Each | 8437.0 | 8437.0 | 26.0 | False | None | None | False | None | False | 219362.0 | 0 | 3092413 | 106304 | None | code52 | Supplying Installing, testing and commissioning of Hose reel cabin ---- etc., complete with all lead | Each | 6619.8 | 6619.8 | 26.0 | False | None | None | False | None | False | 172114.8 | 0 | 3092414 | 106304 | None | code53 | Supplying Installing, of M.S. Pressed reel of 600mm dia swinging type motion which allows a 180swing and conforms to IS:884/85 or Aluminium fitting Single Piece Compact Type. including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all lead | Each | 6749.6 | 6749.6 | 26.0 | False | None | None | False | None | False | 175489.6 | 0 | 3092415 | 106304 | None | code54 | Supplying Installing, testing and commissioning of 19mm dia 40.0m length hose with rubber lining smooth bore, reinforced of natural/synthetic fibres, a rubber cover finish shall be smooth, fluted or fabric marked with minimum thickness of 1.50mm and to with stand a working pressure of 10Kgf/sqcm confirms & tested as per IS 444/ IS 12585 including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all lead | Each | 7788.0 | 7788.0 | 26.0 | False | None | None | False | None | False | 202488.0 | 0 | 3092416 | 106304 | None | code55 | Supplying Installing, testing and commissioning of Gun metal AIR RELEASE VALVE SIZE OF 25mm dia including cost of materials, labour, usage charges of machinery complete as per specifications. complete ---- etc., complete with all lead | Each | 1947.0 | 1947.0 | 8.0 | False | None | None | False | None | False | 15576.0 | 0 | 3092417 | 106304 | None | code56 | SITC of Gun metal BALL VALVE SIZE OF 25mm dia ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work ---- etc., complete with all lead | Nos | 1557.6 | 1557.6 | 26.0 | False | None | None | False | None | False | 40497.6 | 0 | 3092418 | 106304 | None | code57 | SITC of Gun metal BALL VALVE SIZE OF 20mm dia ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work ---- etc., complete with all lead | Nos | 1233.1 | 1233.1 | 26.0 | False | None | None | False | None | False | 32060.6 | 0 | 3092419 | 106304 | None | code58 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. ---- etc., complete with all lead | Nos | 406.27 | 406.27 | 47.0 | False | None | None | False | None | False | 19094.69 | 0 | 3092420 | 106304 | None | code59 | Supplying Installing, testing and commissioning of approved make 15mm dia sprinkler bulb pendent/upwrite type standard response standard coverage, sprinkler, ---- etc., complete with all lead | Each | 486.75 | 486.75 | 1435.0 | False | None | None | False | None | False | 698486.25 | 0 | 3092421 | 106304 | None | code60 | Supplying, installing of horizontal side wall type, standard response, standard coverage, sprinkler,K 5.6 (80), 1/2 NPT, 68 Degree C, Crome finish UL listed. ---- etc., complete with all lead | Each | 454.3 | 454.3 | 90.0 | False | None | None | False | None | False | 40887.0 | 0 | 3092422 | 106304 | None | code61 | Supplying, installing of concealed type , standard response, standard coverage, sprinkler,K 5.6 (80), 1/2 NPT, 68 Degree C, Crome finish UL listed. ---- etc., complete with all lead | Each | 1038.4 | 1038.4 | 26.0 | False | None | None | False | None | False | 26998.4 | 0 | 3092423 | 106304 | None | code62 | Supplying Installing, testing and commissioning of Ceiling Mounted powder coated Surface Finishing Mild Steel Rosette Plate including cost of materials, labour, usage charges of machinery complete as per specifications ---- etc., complete with all lead | Each | 142.78 | 142.78 | 200.0 | False | None | None | False | None | False | 28556.0 | 0 | 3092424 | 106304 | None | code63 | Stainless steel braided flexible pipe (hose) for dropping sprinklers below false ceiling, pipe shall be 16 bar pressure rating and 1500 mm long 25 mm dia with union / reducer collar, clamps etc. as required. ---- etc., complete with all lead | Each | 3245.0 | 3245.0 | 140.0 | False | None | None | False | None | False | 454300.0 | 0 | 3092425 | 106304 | None | code64 | Supply, erection, testing and commissioning of 1 GI/MS collar. ---- etc.,complete with all leads And lifts as per specifications and as directed by the Engineer-in-charge . ---- etc., complete with all lead | Nos | 142.78 | 142.78 | 2070.0 | False | None | None | False | None | False | 295554.6 | 0 | 3092426 | 106304 | None | code65 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all lead | Kg | 190.81 | 190.81 | 3700.0 | False | None | None | False | None | False | 705997.0 | 0 | 3092427 | 106304 | None | code66 | Supplying, installing, testing and commissioning of EXTERNAL yard hydrant comprising of the following, of 63mm dia single headed Gun mental Hydrant Valve with flanged inlet, stop valve,spindle and cast iron hand wheel. It has a female instantaneous outlet with Blank Cap and is Hydrostatically tested to 21 Kgf/cm2 pressure having a flow rate of 900 LPM at 7 Kgf/cm 2 of pressure with blank cap and wheel as per IS 5290 etc. complete including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all lead | No | 13629.0 | 13629.0 | 13.0 | False | None | None | False | None | False | 177177.0 | 0 | 3092428 | 106304 | None | code67 | Supplying Installing, testing and commissioning of Reinforced Rubber Lined RRL Fire hose of 63mm dia 15m length as per IS 8423 binded with one set of male and Female lnstantainious Gun metal coupling as per IS 903 complete including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all lead | Each | 6490.0 | 6490.0 | 26.0 | False | None | None | False | None | False | 168740.0 | 0 | 3092429 | 106304 | None | code68 | Supplying Installing, testing and commissioning of Gun metal Branch pipe size of 63mm dia x19mm dia as per IS 903 complete including cost of materials, labour,usage charges of machinery complete as per specifications. ---- etc., complete with all lead | Each | 5841.0 | 5841.0 | 13.0 | False | None | None | False | None | False | 75933.0 | 0 | 3092430 | 106304 | None | code69 | Supplying Installing, testing and commissioning of Hose cabinet made out of 18
gauge M.S.sheet with double glass door with lacing arrangement and painted with
two coats of Fire red Enamel paint at outer ise of the Box and two coats of white
enamel paint at inner side of the box is to accomodated 2 Nos. of Fire hose box size
20x24x10 complete including cost of materials, labour, usage charges of
machinery complete as per specifications. ---- etc., complete with all lead | Each | 8437.0 | 8437.0 | 13.0 | False | None | None | False | None | False | 109681.0 | 0 | 3092431 | 106304 | None | code70 | CO2 2Kg Squeeze grip
Providing 2 Kg C02 Gas Type Fire Extinugisher Squeeze grip type, used Unused Mechanism, Squeeze Grip, Gross Weight 9.1 Kg. empty Weight 7.1 Kg. Can Height 595MM Diameter 108MM, Discharge Time less than 8 Sees, Controllable discharge
mechanism, Applicable on Class 8&C Fire, 8 Rating 88, Can Construction : Hot spinning/Forging, Valve Construction : Forging & Machining, Internal Coating of Can : Not Applicable, External coating of Can : Spray Painting, Sheet metal thickness: 4.0MM lSI Approved, 1 Year Warranty.with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete ---- etc., complete with all lead | Each | 5321.8 | 5321.8 | 74.0 | False | None | None | False | None | False | 393813.2 | 0 | 3092432 | 106304 | None | code71 | C02 4.5Kg Squeeze grip:-Providing 4.5Kg CO2 Gas Type Fire Extinugisher, Trolley Mounted, 2 Easy Weight Management used Unused Mechanism, Squeeze Grip, Gross Weight 19.1 Kg. empty Weight 14.6 Kg. Can Height 860MM Diameter 140MM, Discharge Time less than13 Sees, Controllable discharge mechanism, Applicable on Class 8&C Fire, 8 Rating138, Can Constuctin : Hot spinning/Forging, Valve Construction : Forging & Machining, Internal Coating of Can : Not Applicable, External coating of Can : Spray Painting, Sheet metal thickness : 4.5M M lSI Approved 1Year Warranty. with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications.complete ---- etc., complete with all lead | Each | 9735.0 | 9735.0 | 66.0 | False | None | None | False | None | False | 642510.0 | 0 | 3092433 | 106304 | None | code72 | Providing Aqueous Film-Forming Foam - 9 Ltr
Providing 9 Ltr Fire Extinugisher Aqueous Film-Forming Foam Type, Stored Pressure Type, Pressure Gauge, Gross Weight 15.1Okg. empty weight 6.10kg Can Height 615 MM, Diameter 175 MM, Discharge Time less than 60 Sees, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 6
Meters, applicable on Class A,8,CARating 13A, 8 Rating 558, Can Construction;Deep drawn & CO, Mig welded, Valve Construction: Forging & Machining, Internal Coating of Can : Epoxy Powder coating, External Coating of Can : Epoxy PoIyster
Powder coating, Sheet metal thickness: 2.0MM, lSI and EN Approved, Helium Leak Detection Tested, 1 Years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete ---- etc., complete with all lead | Each | 10513.8 | 10513.8 | 10.0 | False | None | None | False | None | False | 105138.0 | 0 | 3092434 | 106304 | None | code73 | Providing ABC Powder based MAP 50, 6Kg:-Providing 6kg Fire Extinguisher Mono Ammonium Phos phate Powder 50, Stored Pressure Type, Pressure Gauge, Gross Weight 9.5 Kg, empty weight 3.5 Kg, Can Height 435MM, Diameter 160MM, Discharge Time less than 9 Sees, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 4 meters, applicable on Class A,8,C and electrically started Fire, A Rating 3A, 8 Rating 218, Can construction : Deep drawn & Co., Mig welded, valve Construciton : Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy PoIyster power coating, Sheet metal thickness: 1.60MM, 5 years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete. IS 15683 Approved, CE Marked ---- etc., complete with all lead | Each | 3699.3 | 3699.3 | 38.0 | False | None | None | False | None | False | 140573.4 | 0 | 3092435 | 106304 | None | code74 | Supplying of two bucket stand along with buckets. Complete ---- etc., complete with all lead | Each | 1427.8 | 1427.8 | 20.0 | False | None | None | False | None | False | 28556.0 | 0 | 3092436 | 106304 | None | code75 | Providing and fixing 6 lts water Mist, stored pressure type fire extinguishers consisting of welded MS cylindrical body, squeeze lever discharge valve fitted with pressure indicating gauge internal discharge tube, 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to ISI finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. ---- etc., complete with all lead | Nos | 9994.6 | 9994.6 | 26.0 | False | None | None | False | None | False | 259859.6 | 0 | 3092437 | 106304 | None | code76 | Providing and fixing 3 lts water Mist, stored pressure type fire extinguishers consisting of welded MS cylindrical body, squeeze lever discharge valve fitted with pressure indicating gauge internal discharge tube, 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to ISI finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. ---- etc., complete with all lead | Nos | 9215.8 | 9215.8 | 26.0 | False | None | None | False | None | False | 239610.8 | 0 | 3092438 | 106304 | None | code77 | Supplying of two bucket stand alongwith buckets. complete ---- etc., complete with all lead | Each | 1427.8 | 1427.8 | 8.0 | False | None | None | False | None | False | 11422.4 | 0 | 3092439 | 106304 | None | code78 | Providing and fixing in position the following type of sign boards made out of 3mm thick Opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners. Providings Escape Singage Photoluminescent rigid plastic, 2 mm thickness, Printed on High Quality glass paint with UV resistance, 5 years warranty, Material Used - Non Radiocactive, non-phosphorous, non toxic and lead free. Available in different types & sizes, Time after removing the light source (in minutes) 60 minutes, Luminescent intensity (milicandelas * per square meter - mcd/sqm) : 30 mcd/sqm.Luminescent Intensity greater than 0.32 mcd/sqm, Period of Light Decay* (In Minutes) :3100, including cost of materials, labour, usage charges of machinery complete as per specifications.(Signage with the following text IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE Size:-25cm x 30 cm) ---- etc., complete with all lead | Sq CM | 2.6 | 2.6 | 13500.0 | False | None | None | False | None | False | 35100.0 | 0 | 3092440 | 106304 | None | code79 | Providings Escape Singage Photoluminescent rigid plastic, 2 mm thickness, Printed on High Quality glass paint with UV resistance, 5 years warranty, Material Used - Non Radiocactive, non-phosphorous, non toxic and lead free. Available in different types & sizes, Time after removing the light source (in minutes) 60 minutes, Luminescent intensity (milicandelas * per square meter - mcd/sqm) : 30 mcd/sqm.Luminescent Intensity greater than 0.32 mcd/sqm, Period of Light Decay* (In Minutes) :3100, including cost of materials, labour, usage charges of machinery complete as per specifications.(Floor identification signage ( ie, GROUND FLOOR …etc.) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 7.5 cm with contrasting colour from back ground.Size shall be 15cm x 60cm.) ---- etc., complete with all lead | Sq CM | 2.6 | 2.6 | 1350.0 | False | None | None | False | None | False | 3510.0 | 0 | 3092441 | 106304 | None | code80 | Providings Escape Singage Photoluminescent rigid plastic, 2 mm thickness, Printed on High Quality glass paint with UV resistance, 5 years warranty, Material Used - Non Radiocactive, non-phosphorous, non toxic and lead free. Available in different types & sizes, Time after removing the light source (in minutes) 60 minutes, Luminescent intensity (milicandelas * per square meter - mcd/sqm) : 30 mcd/sqm.Luminescent Intensity greater than 0.32 mcd/sqm, Period of Light Decay* (In Minutes) :3100, including cost of materials, labour, usage charges of machinery complete as per specifications.(signage with text FIRE EXIT,Size shall be 15cm x 60cm.) ---- etc., complete with all lead | Sq CM | 2.6 | 2.6 | 16200.0 | False | None | None | False | None | False | 42120.0 | 0 | 3092442 | 106304 | None | code81 | Providing and fixing in position the signages FIRE ORDER it should contain the following text on 3mm thick Opaque PVC foam board of computerized cut, PVC non-reflective self adhesive vinyl painted foam board of size 3 x 4. A) ALERT THE SECURITY AT SECURITY ROOM BY ACTUATING MANUAL CALL POINT LOCATED AT STRATEGIC LOCATIONS. B) EVACUATE THE OCCUPANTS BY USING FIRE EXITS AND EMERGENCY EXITS ONLY AND ASSEMBLE AT VARIOUS ASSEMBLY POITS. C) IF POSSIBLE TRY TO EXTINGUISH THE FIRE BY USING NEAREST / SUITABLE PORTABLE EXTINGUISHER OR WATER FROM NEAREST WET RISER. D) BE CALM AND DO NOT GIVE ANY ROOM FROM PANIC, WALK, DO NOT RUN. E) IF YOU ENCOUNTER SERIOUS DIFFICULTY IN EVACUATION, LIE DOWN FLAT AND TRY TO ATTRACT ATTENTION OF RESCUE TEAM. ---- etc., complete with all lead | Each | 3245.0 | 3245.0 | 19.0 | False | None | None | False | None | False | 61655.0 | 0 | 3092443 | 106304 | None | code82 | ACTION BY SECURITY/RECEPTION UPON RECEIPT OF INFORMATION THROUGH FIRE ALARM OR FIRE DETECTORS OR BY USING PUBLIC ADDRESS SYSTEM. A) ALERT THE OCCUPANTS BY USING PUBLIC ADDRESS SYSTEM. B) INFORM FIRE CONTROL THROUGH ANY ONE OF THE FOLLOWING PHONE NUMBERS: (Current phone numbers to be provided in this location by the contractor) C) REFER EVACUATION PLAN FROM EVACUATING STANDARD PEOPLE. D) GUIDE THE FIRE FORCE, ON THEIR ARRIVAL TO THE SEAT OF FIRE. E) IN CASE OF THE CASUALTIES, CALL AMBULANCE BY DIALLING NUMBER: (Current phone numbers to be provided in this location by the contractor) F) FIRE FIGHTING AGENCY: PHONE : (Current phone numbers to be provided in this location by the contractor) FAX : (Current fax numbers to be provided in this location by the contractor) ---- etc., complete with all lead | Each | 3245.0 | 3245.0 | 19.0 | False | None | None | False | None | False | 61655.0 | 0 | 3092444 | 106304 | None | code83 | Providings Escape Singage Photoluminescent rigid plastic, 2 mm thickness, Printed on High Quality glass paint with UV resistance, 5 years warranty, Material Used - Non Radiocactive, non-phosphorous, non toxic and lead free. Available in different types & sizes, Time after removing the light source (in minutes) 60 minutes, Luminescent intensity (milicandelas * per square meter - mcd/sqm) : 30 mcd/sqm.Luminescent Intensity greater than 0.32 mcd/sqm, Period of Light Decay* (In Minutes) :3100, including cost of materials, labour, usage charges of machinery complete as per specifications.(route plan Fire Escape Route Plan A2 Size) ---- etc., complete with all lead | Each | 2.6 | 2.6 | 18000.0 | False | None | None | False | None | False | 46800.0 | 0 | 3092445 | 106304 | None | code84 | Supply installation testing commissioning of P.A System Rack made out of 18 gauge M.S. Sheet with glass door with locking arrangement and powder coating grey paint two coats at inner and outer of box, is to accomodated 1 No 250 watt amplifire, 1 No 40 zone console and 1 no Mike and in built electronic connections circuits.Size or Rack: 0.50 m hight x 0.40 m width x 0.40 m depth ---- including all lead and lift charges loading and unloading charges labour charges, curing, cost& conveyance of all materials, transportation charges, all incidental charges, hire charges of all machinery and equipment required for successful completion of work etc., complete. The work shall be executed as per standard technical specification and directions of Engineer in charge of the work ---- etc., complete with all lead | Nos | 64251.0 | 64251.0 | 2.0 | False | None | None | False | None | False | 128502.0 | 0 | 3092446 | 106304 | None | code85 | Supplying Installing, testing and commissioning of P.A.System console panel with push button with speaker and indictoron Accomdated in M.S.Cabinet with painting -do- 20 Zone cansole. Complete ---- etc., complete with all lead | Nos | 54516.0 | 54516.0 | 3.0 | False | None | None | False | None | False | 163548.0 | 0 | 3092447 | 106304 | None | code86 | P.A.System amplifier 250W RMS out put with complete wiring and controls accessable form front ---- etc., complete with all lead | Nos | 45754.5 | 45754.5 | 3.0 | False | None | None | False | None | False | 137263.5 | 0 | 3092448 | 106304 | None | code87 | Supplying Installing, testing and commissioning of MIKE ---- etc., complete with all lead | Each | 7139.0 | 7139.0 | 3.0 | False | None | None | False | None | False | 21417.0 | 0 | 3092449 | 106304 | None | code88 | Supplying Installing, testing and commissioning of Public address system (Two way comminication type) as per requirement of Fire Force authority and which Generally comprise of Supplying Installing, testing and commissioning of Approved make 5W.wall mounted speaker with talk back facility with store enamel painted M.S.Sheet hosing etc. complete including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all lead | Each | 3180.1 | 3180.1 | 28.0 | False | None | None | False | None | False | 89042.8 | 0 | 3092450 | 106304 | None | code89 | Supply & Laying of 2 X 1.5 Sqmm fire alarm armored cable,600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. ---- etc., complete with all lead | Mtr | 194.7 | 194.7 | 4925.0 | False | None | None | False | None | False | 958897.5 | 0 | 3092451 | 106304 | None | code90 | Supply, install, test and commissioning of addressable peer to peer Networkable analogue addressable type fire alarm control panel with minimum 1500 Character /240X64 Pixel / 7inch Touchscreen graphic LCD display. The panel should be equipped with sufficient numbers of loop with 20% spare capacity, with each networkable intelligent fire alarm Control Panel having SLC with capacity of min 126/240 detectors/ devices in any combination with key pad, dual flash-based microprocessor technology, inbuilt USB Port for upload and down load the configuration tools, RS232 serial port for direct PC or modem connection, inbuilt NACs, min 20 programmable Zonal LEDs and operates on 240V AC + 10% with 50Hz with built in charger. The panel shall have fire, fault relays, option of BMS
integration MODBUS/ BACKNET, graphical software for provision of TCP/ IP modules, Remote Access, Class X wiring with provision of both class A and class B wiring in the SLC circuit, user friendly with communication facility to monitor & control the FACPs from a single window. The panel shall be suitable for minimum of 5000 event record facility, event fetch from FACP facility and the single panel shall be suitable for min 2000 fire zones and 200 Panels/ Nodes in one network with all other accessories required to successfully run the system. (The System cost shall be included of all necessary cards, modules, Panel enclosure, CPU and associated accessories to complete the system design). Approval: VDS/UL/EN-54 Std. 4 Loop Panel ---- etc., complete with all lead | Each | 324500.0 | 324500.0 | 3.0 | False | None | None | False | None | False | 973500.0 | 0 | 3092452 | 106304 | None | code91 | Supply, install, test and commissioning of addressable peer to peer Networkable analogue addressable type fire alarm control panel with minimum 1500 Character /240X64 Pixel / 7inch Touchscreen graphic LCD display. The panel should be equipped with sufficient numbers of loop with 20% spare capacity, with each networkable intelligent fire alarm Control Panel having SLC with capacity of min 126/240 detectors/ devices in any combination with key pad, dual flash-based microprocessor technology, inbuilt USB Port for upload and down load the configuration tools, RS232 serial port for direct PC or modem connection, inbuilt NACs, min 20 programmable Zonal LEDs and operates on 240V AC + 10% with 50Hz with built in charger. The panel shall have fire, fault relays, option of BMS
integration MODBUS/ BACKNET, graphical software for provision of TCP/ IP modules, Remote Access, Class X wiring with provision of both class A and class B wiring in the SLC circuit, user friendly with communication facility to monitor & control the FACPs from a single window. The panel shall be suitable for minimum of 5000 event record facility, event fetch from FACP facility and the single panel shall be suitable for min 2000 fire zones and 200 Panels/ Nodes in one network with all other accessories required to successfully run the system. (The System cost shall be included of all necessary cards, modules, Panel enclosure, CPU and associated accessories to complete the system design). Approval: VDS/UL/EN-54 Std 2 Loop Panel ---- etc., complete with all lead | Each | 272580.0 | 272580.0 | 3.0 | False | None | None | False | None | False | 817740.0 | 0 | 3092453 | 106304 | None | code92 | Supply, intallation, testing and Commissioning of Graphical software for entire fire alarm panels including detector configuration, commissioning etc ---- etc., complete with all lead | Each | 260393.08 | 260393.08 | 2.0 | False | None | None | False | None | False | 520786.16 | 0 | 3092454 | 106304 | None | code93 | Supply, intallation, testing and Commissioning of Network card for fire alram panels integration ---- etc., complete with all lead | Each | 77880.0 | 77880.0 | 6.0 | False | None | None | False | None | False | 467280.0 | 0 | 3092455 | 106304 | None | code94 | Supplying Installing, testing and commissioning of Response Indicator constists of twin LED wioth electronic circutarx work on 24 DC enclose in PVC retangular. complete including cost of materials, labour, HOM complete as per specifications. ---- etc., complete with all lead | Each | 324.5 | 324.5 | 80.0 | False | None | None | False | None | False | 25960.0 | 0 | 3092456 | 106304 | None | code95 | Supply, Installation , Testing & Commissioning of Network Active Repeater Panel with 1500 Character / 240X64 Pixel / 7inch Touchscreen. The LCD shall Display all events / detectors, devices status of complete systems in the networked. Approval: UL/VDS/EN54. Make: ---- etc., complete with all lead | Each | 84370.0 | 84370.0 | 2.0 | False | None | None | False | None | False | 168740.0 | 0 | 3092457 | 106304 | None | code96 | Supply, intallation, testing and Commissioning of loop card ---- etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead | Each | 3634.4 | 3634.4 | 8.0 | False | None | None | False | None | False | 29075.2 | 0 | 3092458 | 106304 | None | code97 | Supply Installation testing & Commissioning of conventional type photo/Heat
electric smoke sensor with flashing LED capable of woking at 9V to 33 V DC .The
Optical Smoke Detector is unaffected by wind or atmosphericpressure and operates over the temperature range -20C to +60C. IP Rating at IP 23D & Approval with EN-54 -7, LPCB Approved. ---- etc., complete with all lead | Each | 2725.8 | 2725.8 | 600.0 | False | None | None | False | None | False | 1635480.0 | 0 | 3092459 | 106304 | None | code98 | SITC OF Fault isolation module:- Supply, Erection,Testing and Commissioning of UL-APPROVED Analog addressable fault isolator circuit modules of wall mounted type with mounting accessories. ---- etc., complete with all lead | Each | 7788.0 | 7788.0 | 29.0 | False | None | None | False | None | False | 225852.0 | 0 | 3092460 | 106304 | None | code99 | Supply, Installation, Testing & Commissioning of Analogue Addressable loop powered Sounder & Beacon with inbuilt isolator and having Min 15 distinct sound patterns/ multitone to indicate Exit doors and direct occupants for safe and fast evacuation and 100dB output with minimum 1Hz Frequency flash rate designed for IP65 requirements and approved to operate in 10C to +55C temperature, complies with the essential requirement of the EMC Directive to be supplied with Junction Box, Glands and other mounting accessories for proper installation. (For Detectors/Device without inbuilt isolator, Fault Isolator or Isolator base to be provided with each detector/device) Approval: VDS/UL/EN54. Make: Advanced (UK),Simplex, Notifier,Argus(Uk) ---- etc., complete with all lead | Each | 6360.2 | 6360.2 | 26.0 | False | None | None | False | None | False | 165365.2 | 0 | 3092461 | 106304 | None | code100 | Supplying Installing, testing and commissioning of Resettable type Manual Call point . works on 24V DC LED indicator with glass Fronted. Fire Symbol .The red Manual Call Point is approved to EN54-11 standard. MECHANICAL CONSTRUCTION The component parts of the call point are moulded in polycarbonate or ABS, depending on their function. ---- etc., complete with all lead | Each | 3894.0 | 3894.0 | 28.0 | False | None | None | False | None | False | 109032.0 | 0 | 3092462 | 106304 | None | code101 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.100 x 75 x 65 mm ---- etc., complete with all lead | Each | 153.16 | 153.16 | 650.0 | False | None | None | False | None | False | 99554.0 | 0 | 3092463 | 106304 | None | code102 | Supply, install, test and commissioning of Analogue addressable Monitor Cum
Control (Input/Output) module (1+1) with inbuilt relay and isolator with LED
indicator, approved to operate in 10C to +55C temperature, complies with the
essential requirement of the EMC Directive to be supplied with Junction Box, Glands and other mounting accessories for proper installation. In case of Manufacturer with single Input or Output module need to supply One quantity of each for line item.(For Detectors/Device without inbuilt isolator, Fault Isolator or Isolator base to be provided with each detector/device) Approval: EN54. ---- etc., complete with all lead | Each | 5062.2 | 5062.2 | 28.0 | False | None | None | False | None | False | 141741.6 | 0 | 3092464 | 106304 | None | code103 | Supply, intallation, testing and Commissioning of 2C 1.5 sq mm armoured FRLS cables in celing with suitable clamps and screws (RED colour) ---- etc., complete with all lead | Mtr | 194.7 | 194.7 | 7450.0 | False | None | None | False | None | False | 1450515.0 | 0 | 3092465 | 106304 | None | code104 | SITC of 7AM-12 V Battery for fire alarm system ---- etc., complete with all lead | Each | 1390.16 | 1390.16 | 12.0 | False | None | None | False | None | False | 16681.92 | 0 | 3092466 | 106304 | None | code105 | Supplying Installing, testing and commissioning of electronic Hooter, it conists of electronic circuit to give dual Fire alaram sound with works. ---- etc., complete with all lead | Each | 4543.0 | 4543.0 | 2.0 | False | None | None | False | None | False | 9086.0 | 0 |
|
|
---|