createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1710490070259
version2
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee820.00
emd50000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose05-04-2024 16:30:00
tenderQueryClose04-04-2024 16:30:00
technicalBidOpen06-04-2024 17:00:00
publishedDate15-03-2024 16:13:04
publishedByPostTP_CO_KDG
publishedByUserKPE14508 - FEROZ KHAN
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonFerozKhan
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08391220049
mobileNumber9902857458
tenderSupplierListNone
tenderSchedule
createdTs1710490070290
version5
createdDateNone
modifiedDateNone
tenderNumberDMA/2023-24/BD/WORK_INDENT17650
titleConstruction of Proposed 4 TPD MRF Centre (Material Recovery Facility) of PEB Structure (PRIMARY & SECONDARY SHED) at SWM Site Town Panchayath Kudligi Limit.
descriptionConstruction of Proposed 4 TPD MRF Centre (Material Recovery Facility) of PEB Structure (PRIMARY & SECONDARY SHED) at SWM Site Town Panchayath Kudligi Limit.
categoryWORKS
categoryTextWorks
ecv3247294.67
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2482
locationNameDMA Town Panchayat Kudligi
provisionalAmount4000000.0
groupOverheadTotalNone
fileNumberTPKDL/MRF/2023-24/001
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17104900700001NoneNoneBuildingsConstruction of Proposed 4 TPD MRF Centre (Material Recovery Facility) of PEB Structure (PRIMARY & SECONDARY SHED) at SWM Site Town Panchayath Kudligi Limit.3247294.67
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3086825106040Noneitem_code1KSRB 1-1.14.1: Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. (Item No. 1.14.1 Page No. 8 Vol.1 PWD SR 2023-24)Cum105.06105.0636.64FalseNoneNoneFalseNoneFalse3849.39840
3086826106040Noneitem_code2KSRB 2-2.1.2: Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement & formwork shall be paid separately. Specification No. KBS 2.1, (Item No. 2.1.2 Page No. 15 Vol.1 PWD SR 2023-24)Cum5833.925833.9236.18FalseNoneNoneFalseNoneFalse211071.22560
3086827106040Noneitem_code3KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & 2023-24 Appendix I page No.115) For footingCum7192.87192.89.04FalseNoneNoneFalseNoneFalse65022.9120
3086828106040Noneitem_code4KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & 2023-24 Appendix I page No.115) For column baseCum11210.411210.41.94FalseNoneNoneFalseNoneFalse21748.1760
3086829106040Noneitem_code5KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & 2023-24 Appendix I page No.115) For hall grade slabCum7192.87192.840.7FalseNoneNoneFalseNoneFalse292746.960
3086830106040Noneitem_code6KSRB 2-2.2.3.1 :Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No. 2.2.3 Page No. 15 Vol.1 PWD SR 2023-24 & Appendix I page No.115) for plinth beamCum9694.089694.085.98FalseNoneNoneFalseNoneFalse57970.59840
3086831106040Noneitem_code7KSRB 2.11 Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (Item No. 2.11 Page No. 18 Vol.1 PWD SR 2023-24)Tonne92140.7192140.713.71FalseNoneNoneFalseNoneFalse341842.03410
3086832106040Noneitem_code8KSRB 5-5.4: Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) . (Item No. 5.4 Page No. 9 Vol.2 PWD SR 2023-24)Cum6580.676580.6717.43FalseNoneNoneFalseNoneFalse114701.07810
3086833106040Noneitem_code9KSRB 1-1.8: Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work (Item No. 1.8 Page No. 7 Vol.1 PWD SR 2023-24)Cum474.0474.0183.14FalseNoneNoneFalseNoneFalse86808.360
3086834106040Noneitem_code10KSRB 6-6.33: Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Item No. 6.33 Page No. 17 Vol.2 PWD SR 2023-24)Sqm1267.961267.96106.06FalseNoneNoneFalseNoneFalse134479.83760
3086835106040Noneitem_code11KSRB 8-8.3.1: Providing 15mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Item No. 8.2.1, Page No. 41, Vol.2 2023-24)Sqm303.85303.85225.61FalseNoneNoneFalseNoneFalse68551.59850
3086836106040Noneitem_code12Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. (Item No. 11.2, Page No. 77, Vol.2 2023-24)Kgs116.39116.398380.0FalseNoneNoneFalseNoneFalse975348.20
3086837106040Noneitem_code13Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Item No. 7.38, Page No. 26, Vol.2 2023-24)Sqm585.04585.04590.76FalseNoneNoneFalseNoneFalse345618.23040
3086838106040Noneitem_code14KSRB 8-8.51 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(Item No. 8.51, Page No. 50, Vol.2 2023-24)Sqm103.0103.0225.61FalseNoneNoneFalseNoneFalse23237.830
3086839106040Noneitem_code15KSRB 8-8.54.1 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.(Item No. 8.54.1, Page No. 50, Vol.2 2023-24)Sqm75.1975.19106.06FalseNoneNoneFalseNoneFalse7974.65140
3086840106040Noneitem_code16KSRB 8-8.75.2 : Finishing walls with Premium Acrylic Smooth exterior paint of required shade : Old work (one coats applied @ 0.83 l/10 m²) including preparing the surface after thoroughly cleaning the surface to remove all dirt,dust and foreign matter , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(Item No. 8.75.2, Page No. 53, Vol.2 2023-24)Sqm75.1975.19106.06FalseNoneNoneFalseNoneFalse7974.65140
3086841106040Noneitem_code17KSRB 11-11.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Item No. 11.6.1, Page No. 76, Vol.2 2023-24)Sqm2711.992711.9922.5FalseNoneNoneFalseNoneFalse61019.7750
3086842106040Noneitem_code18KSRB 11-11.8.4:Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Item No. 11.8.4, Page No. 77, Vol.2 2023-24)Each25426.5825426.582.0FalseNoneNoneFalseNoneFalse50853.160
3086843106040Noneitem_code19KSRB 11-11.35.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications..(Item No. 11.35.1.1, Page No. 87, Vol.2 2023-24)Kgs465.56465.56240.0FalseNoneNoneFalseNoneFalse111734.40
3086844106040Noneitem_code20LT Control Panel for PHE Equipments, like raw water, treated water, sump water lift pumps including starter control operating system.Completely made by CRCA fabricated, powder coated paint finished front openable compartment for all feeders requirement with IP-54. Main panel Incomer : MCCB TPN 63A with CBCT ELR & Ph indicators, meter section with all parameters as required 100A 4 Wire 25kA 415V Aluminium busbars compartment. Outgoings: 63A MCCB feeder- 01No. Outgoings: 16A MPCB feeder - 01Nos Outgoings: 16A MPCB feeder - 02Nos Outgoings: 63/40A MCB feeder- 08NosNo65000.065000.01.0FalseNoneNoneFalseNoneFalse65000.00
3086845106040Noneitem_code21LT Control Panel for PHE Equipments, like raw water, treated water, sump water lift pumps including starter control operating system.Completely made by CRCA fabricated, powder coated paint finished front openable compartment for all feeders requirement with IP-54. For Sub panel Incomer : MCB TPN 63A with CBCT ELR & Ph indicators, section with all parameters as required Outgoings: 40/63A 4P MCB feeder- 10No. Outgoings: 32A Industrial socket-02Nos. Outgoings: 16A Industrial socket-02Nos.No35000.035000.01.0FalseNoneNoneFalseNoneFalse35000.00
3086846106040Noneitem_code22LT Cables Supply & laying 1.1kV LT UG cable XLPE / heat resistant PVC insulated, PVC extruded inner sheath armoured as per IS:1554 part-1 or IS:7098 part-1, Armouring thickness +5% and resistivity 14 Ohms /Kms Max as per IS: 3975. Glands & Lugs not included. 3.5Cx50 Sqmm Al Ar cableMtr300.0300.030.0FalseNoneNoneFalseNoneFalse9000.00
3086847106040Noneitem_code23LT Cables Supply & laying 1.1kV LT UG cable XLPE / heat resistant PVC insulated, PVC extruded inner sheath armoured as per IS:1554 part-1 or IS:7098 part-1, Armouring thickness +5% and resistivity 14 Ohms /Kms Max as per IS: 3975. Glands & Lugs not included. 4Cx25 Sqmm Al Ar cableMtr180.0180.020.0FalseNoneNoneFalseNoneFalse3600.00
3086848106040Noneitem_code24LT Cables Supply & laying 1.1kV LT UG cable XLPE / heat resistant PVC insulated, PVC extruded inner sheath armoured as per IS:1554 part-1 or IS:7098 part-1, Armouring thickness +5% and resistivity 14 Ohms /Kms Max as per IS: 3975. Glands & Lugs not included. 4Cx16 Sqmm Al Ar cableMtr120.0120.020.0FalseNoneNoneFalseNoneFalse2400.00
3086849106040Noneitem_code25LT Cables Supply & laying 1.1kV LT UG cable XLPE / heat resistant PVC insulated, PVC extruded inner sheath armoured as per IS:1554 part-1 or IS:7098 part-1, Armouring thickness +5% and resistivity 14 Ohms /Kms Max as per IS: 3975. Glands & Lugs not included. 4Cx10 Sqmm Cu Ar cableMtr332.0332.01.0FalseNoneNoneFalseNoneFalse332.00
3086850106040Noneitem_code26LT Cables Supply & laying 1.1kV LT UG cable XLPE / heat resistant PVC insulated, PVC extruded inner sheath armoured as per IS:1554 part-1 or IS:7098 part-1, Armouring thickness +5% and resistivity 14 Ohms /Kms Max as per IS: 3975. Glands & Lugs not included. 4Cx6 Sqmm Cu Ar cableMtr256.0256.01.0FalseNoneNoneFalseNoneFalse256.00
3086851106040Noneitem_code27LT Cables Supply & laying 1.1kV LT UG cable XLPE / heat resistant PVC insulated, PVC extruded inner sheath armoured as per IS:1554 part-1 or IS:7098 part-1, Armouring thickness +5% and resistivity 14 Ohms /Kms Max as per IS: 3975. Glands & Lugs not included. 3Cx6 Sqmm Cu Ar cableMtr316.0316.01.0FalseNoneNoneFalseNoneFalse316.00
3086852106040Noneitem_code28LT Cables Supply & laying 1.1kV LT UG cable XLPE / heat resistant PVC insulated, PVC extruded inner sheath armoured as per IS:1554 part-1 or IS:7098 part-1, Armouring thickness +5% and resistivity 14 Ohms /Kms Max as per IS: 3975. Glands & Lugs not included. 3Cx4 Sqmm Cu Ar cableMtr300.0300.01.0FalseNoneNoneFalseNoneFalse300.00
3086853106040Noneitem_code29Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class. 3.5Cx50 Sqmm Al Ar cableSet200.0200.02.0FalseNoneNoneFalseNoneFalse400.00
3086854106040Noneitem_code30Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class. 4Cx25 Sqmm Al Ar cableSet67.267.22.0FalseNoneNoneFalseNoneFalse134.40
3086855106040Noneitem_code31Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class. 4Cx16 Sqmm Al Ar cableSet67.267.22.0FalseNoneNoneFalseNoneFalse134.40
3086856106040Noneitem_code32Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class. 4Cx10 Sqmm Al Ar cableSet54.454.42.0FalseNoneNoneFalseNoneFalse108.80
3086857106040Noneitem_code33Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class. 4Cx6 Sqmm Al Ar cableSet54.454.42.0FalseNoneNoneFalseNoneFalse108.80
3086858106040Noneitem_code34Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class. 3Cx6 Sqmm Al Ar cableSet54.454.42.0FalseNoneNoneFalseNoneFalse108.80
3086859106040Noneitem_code35Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class. 3Cx4 Sqmm Al Ar cableSet54.454.42.0FalseNoneNoneFalseNoneFalse108.80
3086860106040Noneitem_code36Supply & installation of Tinned Copper lugs crimping & wiring to terminal point. 70 Sqmm Al Ar cable (tinned copper lug)Set250.0250.02.0FalseNoneNoneFalseNoneFalse500.00
3086861106040Noneitem_code37Supply & installation of Tinned Copper lugs crimping & wiring to terminal point. 25 Sqmm Al Ar cable (tinned copper lug)Set16.016.02.0FalseNoneNoneFalseNoneFalse32.00
3086862106040Noneitem_code38Supply & installation of Tinned Copper lugs crimping & wiring to terminal point. 16 Sqmm Al Ar cable (tinned copper lug)Set9.959.952.0FalseNoneNoneFalseNoneFalse19.90
3086863106040Noneitem_code39Supply & installation of Tinned Copper lugs crimping & wiring to terminal point. 10 Sqmm Cu Al Ar cable (tinned copper lug)Set6.46.41.0FalseNoneNoneFalseNoneFalse6.40
3086864106040Noneitem_code40Supply & installation of Tinned Copper lugs crimping & wiring to terminal point. 6 Sqmm cu Al Ar cable (tinned copper lug)Set5.65.61.0FalseNoneNoneFalseNoneFalse5.60
3086865106040Noneitem_code41Supply & installation of Tinned Copper lugs crimping & wiring to terminal point. 6 Sqmm cu Al Ar cable (tinned copper lug)Set5.65.61.0FalseNoneNoneFalseNoneFalse5.60
3086866106040Noneitem_code42Supply & installation of Tinned Copper lugs crimping & wiring to terminal point. 4 Sqmm cu Al Ar cable (tinned copper lug)Set5.65.61.0FalseNoneNoneFalseNoneFalse5.60
3086867106040Noneitem_code43PVC conduits & Accessories Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws 19/20mm dia PVC 2mm thick conduitMtr71.0771.0710.0FalseNoneNoneFalseNoneFalse710.70
3086868106040Noneitem_code44PVC conduits & Accessories Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws 25 mm dia PVC 2mm thick conduitMtr83.4383.4310.0FalseNoneNoneFalseNoneFalse834.30
3086869106040Noneitem_code45PVC conduits & Accessories Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws 32 mm dia PVC 2.5 mm thick conduitMtr109.18109.1810.0FalseNoneNoneFalseNoneFalse1091.80
3086870106040Noneitem_code46PVC conduits & Accessories Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws 40 mm dia PVC 2.5 mm thick conduitMtr153.47153.4710.0FalseNoneNoneFalseNoneFalse1534.70
3086871106040Noneitem_code47Point wiring using Copper wire with switch Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit. 1 Light point upto 3Mtr from switch boardNos293.55293.551.0FalseNoneNoneFalseNoneFalse293.550
3086872106040Noneitem_code48Point wiring using Copper wire with switch Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit. 1 Light point above 3M upto 6Mtr from switch boardNos405.82405.821.0FalseNoneNoneFalseNoneFalse405.820
3086873106040Noneitem_code49Point wiring using Copper wire with switch Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit. 1 Light point above 6M upto 10Mtr from switch boardNos587.1587.11.0FalseNoneNoneFalseNoneFalse587.10
3086874106040Noneitem_code50Point wiring using Copper wire with switch Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit. 2 Light point above 3Mtr upto 6Mtr from switch boardNos729.24729.241.0FalseNoneNoneFalseNoneFalse729.240
3086875106040Noneitem_code51Point wiring using Copper wire with switch Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit. 2 Light point above 6 Mtr upto 10 Mtr from switch boardNos729.24729.241.0FalseNoneNoneFalseNoneFalse729.240
3086876106040Noneitem_code52Point wiring using Copper wire with switch Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit. 3 Light point above 6 Mtr upto 10 Mtr from switch boardNos1085.621085.623.0FalseNoneNoneFalseNoneFalse3256.860
3086877106040Noneitem_code53Circuit main wiring Supply & wiring from distribution board to looping switch boards. Laid wire size 2x2.5 Sqmm Ph-N & 1x1.5Sqmm for E for Lighting circuit wiring laid in existing conduit. 1.0 Sqmm Cu FRLS wireMtr19.5719.57300.0FalseNoneNoneFalseNoneFalse5871.00
3086878106040Noneitem_code54Circuit main wiring Supply & wiring from distribution board to looping switch boards. Laid wire size 2x2.5 Sqmm Ph-N & 1x1.5Sqmm for E for Lighting circuit wiring laid in existing conduit. 1.50 Sqmm Cu FRLS wireMtr26.7826.78300.0FalseNoneNoneFalseNoneFalse8034.00
3086879106040Noneitem_code55Circuit main wiring Supply & wiring from distribution board to looping switch boards. Laid wire size 2x2.5 Sqmm Ph-N & 1x1.5Sqmm for E for Lighting circuit wiring laid in existing conduit. 2.50 Sqmm Cu FRLS wireMtr43.2643.26300.0FalseNoneNoneFalseNoneFalse12978.00
3086880106040Noneitem_code56Circuit main wiring Supply & wiring from distribution board to looping switch boards. Laid wire size 2x2.5 Sqmm Ph-N & 1x1.5Sqmm for E for Lighting circuit wiring laid in existing conduit. 4.0 Sqmm Cu FRLS wireMtr64.8964.8950.0FalseNoneNoneFalseNoneFalse3244.50
3086881106040Noneitem_code57Circuit main wiring Supply & wiring from distribution board to looping switch boards. Laid wire size 2x2.5 Sqmm Ph-N & 1x1.5Sqmm for E for Lighting circuit wiring laid in existing conduit. 6.0 Sqmm Cu FRLS wireMtr94.7694.7650.0FalseNoneNoneFalseNoneFalse4738.00
3086882106040Noneitem_code58Switches & sockets outlets in Existing modular box 6A one way switchNos105.06105.064.0FalseNoneNoneFalseNoneFalse420.240
3086883106040Noneitem_code59Switches & sockets outlets in Existing modular box 6A 5Pin socketNos176.13176.132.0FalseNoneNoneFalseNoneFalse352.260
3086884106040Noneitem_code60Switches & sockets outlets in Existing modular box Stepped fan regulatorNos367.71367.712.0FalseNoneNoneFalseNoneFalse735.420
3086885106040Noneitem_code61Switches & sockets outlets in Existing modular box 6/16A Universal socketNos160.68160.682.0FalseNoneNoneFalseNoneFalse321.360
3086886106040Noneitem_code62Light fixture Supply & fixing of 70W LED light fixture IP 65, included screws accessoris Etc..Considered outdoor type light fitting for equivalent.Nos6971.046971.0410.0FalseNoneNoneFalseNoneFalse69710.40
3086887106040Noneitem_code63Earthing 25x6mm GI Earth StripMtr92.092.060.0FalseNoneNoneFalseNoneFalse5520.00
3086888106040Noneitem_code64Earthing 8.0 SWG GI bare wireMtr15.215.250.0FalseNoneNoneFalseNoneFalse760.00
3086889106040Noneitem_code65Supply & installation of Cable Trays fixed with MS angles, hitech & anchor fastner supports at interval 0.9M interval shall be included complete run below ceiling/wall. Supply & installation of GI Ladder type cable tray 300x50mmMtr400.0400.020.0FalseNoneNoneFalseNoneFalse8000.00
3086890106040Noneitem_code66Pipe earthing Supply & installation of GI PIPE Earthing as per IS:3043 with all installation detailsNos8000.08000.02.0FalseNoneNoneFalseNoneFalse16000.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17104900740000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17104900740000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17104900740001NoneNoneELIGIBILITYNOT APPLICABLENone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneTo qualify for award of this contract each tenderer in its name should have in the last five years in any one year Satisfactorily completed as prime contractor at least one similar work such as of value not less than Rs 20.00LakhsPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneValid GST Registration CertificateCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneValid PWD Contractor Registration CertificateCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneLiquid assets and or availability of credit facilities of no less than Rs 12.00 Lakhs Credit lines/ letters of credit/ certificates from banks for meeting the fund requirement etc. (Banker Certificate is in prescribed format provided in bid document)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneTo qualify for award of this contract each tenderer in its name should have in the last five years i.e.,2018-19 to 2022-23 achieved in at least two financial years a average minimum financial turnover of Rs 40.00 LakhsFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneNOT APPLICABLEOthersNOT APPLICABLE
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- NOT APPLICABLE
NoneNoneNoneNoneNOT APPLICABLEOthersNOT APPLICABLE
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- NOT APPLICABLE
NoneNoneNoneNoneNOT APPLICABLEOthersNOT APPLICABLE
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- NOT APPLICABLE
NoneNoneNoneNoneNOT APPLICABLEOthersNOT APPLICABLE
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- NOT APPLICABLE
NoneNoneNoneNoneNOT APPLICABLEOthersNOT APPLICABLE
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- NOT APPLICABLE
NoneNoneNoneNoneNOT APPLICABLEOthersNOT APPLICABLE
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- NOT APPLICABLE
NoneNoneNoneNoneUpload all other documents as per Bid Document and Eportal conditionsOthersUpload all other documents as per Bid Document and Eportal conditions
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Upload all other documents as per Bid Document and Eportal conditions
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Up Load All Documents As Per Technical Qualification Criteria And Bid DocumentTrueTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
BuildingsVijayanagaraKudligiBellaryKUDLIGIAT SWM Site NearNoneNoneNoneNoneNoneNone
tenderAddressNone
tenderRecallDTONone