createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1710328253814
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee1640.00
emd159000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose30-03-2024 16:30:00
tenderQueryClose28-03-2024 16:30:00
technicalBidOpen01-04-2024 16:30:00
publishedDate13-03-2024 19:49:09
publishedByPostTMC_CO_SND
publishedByUserKPE15605 - K JAYANNA
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonArun patil
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber8105972226
tenderSupplierListNone
tenderSchedule
createdTs1710328253846
version4
createdDateNone
modifiedDateNone
tenderNumberDMA/2023-24/DA/WORK_INDENT15734
titleConstruction of Proposed 5TPD MRF Centre (Material Recovery Facility) of PEB Structure (PRIMARY & SECONDARY SHED) in Sandur TMC Limit
descriptionConstruction of Proposed 5TPD MRF Centre (Material Recovery Facility) of PEB Structure (PRIMARY & SECONDARY SHED) in Sandur TMC Limit
categoryWORKS
categoryTextWorks
ecv6546356.77
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location2233
locationNameDMA Town Municipal Council Sanduru
provisionalAmount7950000.0
groupOverheadTotal0.0
fileNumbertmcsdr/MRFcivil/2023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17103282540000NoneNoneDam and Allied worksConstructionn of Proposed 5TPD MRF Centre (Material Recovery Facility) of PEB Structure (PRIMARY & SECONDARY SHED) in Sandur TMC Limit6546356.77
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3041236102757Nonecode01KSRB 1-1.14.1: Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. (Item No. 1.14.1 Page No. 8 Vol.1 PWD SR)Cum107.1107.180.53FalseNoneNoneFalseNoneFalse8624.7630
3041237102757Nonecode02KSRB 2-2.1.2: Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement & formwork shall be paid separately. Specification No. KBS 2.1, (Item No. 2.1.2 Page No. 15 Vol.1 PWD SR)Cum5947.25947.261.08FalseNoneNoneFalseNoneFalse363254.9760
3041238102757Nonecode03KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115)Cum6804.06804.0100.57FalseNoneNoneFalseNoneFalse684278.280
3041239102757Nonecode04Rates of Formwork Shall be Added on percentage basis to finished concrete Item rate ForVarious Work Addendum I Percentage Additionalities for Formwork,Centering & Scaffolding For FootingCum544.32544.3225.98FalseNoneNoneFalseNoneFalse14141.43360
3041240102757Nonecode05Rates of Formwork Shall be Added on percentage basis to finished concrete Item rate ForVarious Work Addendum I Percentage Additionalities for Formwork,Centering & Scaffolding For ColumnCum4762.84762.88.89FalseNoneNoneFalseNoneFalse42341.2920
3041241102757Nonecode06Rates of Formwork Shall be Added on percentage basis to finished concrete Item rate ForVarious Work Addendum I Percentage Additionalities for Formwork,Centering & Scaffolding For Hall Grade slabCum544.32544.3265.7FalseNoneNoneFalseNoneFalse35761.8240
3041242102757Nonecode07KSRB 2-2.2.3.1 :Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No. 2.2.3 Page No. 15 Vol.1 PWD SR & Appendix I page No.115)Cum6652.86652.88.2FalseNoneNoneFalseNoneFalse54552.960
3041243102757Nonecode08Rates of Formwork Shall be Added on percentage basis to finished concrete Item rate ForVarious Work Addendum I Percentage Additionalities for Formwork,Centering & Scaffolding For FootingCum3326.43326.48.2FalseNoneNoneFalseNoneFalse27276.480
3041244102757Nonecode09KSRB 2.11 Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (Item No. 2.11 Page No. 18 Vol.1 PWD SR)t93929.8593929.859.03FalseNoneNoneFalseNoneFalse848186.54550
3041245102757Nonecode10KSRB 5-5.4: Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) . (Item No. 5.4 Page No. 9 Vol.2 PWD SR)Cum6708.456708.4532.75FalseNoneNoneFalseNoneFalse219701.73750
3041246102757Nonecode11KSRB 1-1.8: Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work (Item No. 1.8 Page No. 7 Vol.1 PWD SR)Cum488.22488.22360.89FalseNoneNoneFalseNoneFalse176193.71580
3041247102757Nonecode12KSRB 6-6.33: Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Item No. 6.33 Page No. 17 Vol.2 PWD SR)Sqm1292.551292.55134.64FalseNoneNoneFalseNoneFalse174028.9320
3041248102757Nonecode13KSRB 8-8.3.1: Providing 15mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Item No. 8.3.1, Page No. 41, Vol.2)Sqm309.75309.75293.04FalseNoneNoneFalseNoneFalse90769.140
3041249102757Nonecode14Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. (Item No. 11.2, Page No. 77, Vol.2)Kg118.65118.6521800.0FalseNoneNoneFalseNoneFalse2586570.00
3041250102757Nonecode15Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Item No. 7.38, Page No. 26, Vol.2)Sqm585.04585.041159.38FalseNoneNoneFalseNoneFalse678283.67520
3041251102757Nonecode16KSRB 8-8.51 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(Item No. 8.51, Page No. 50, Vol.2)Sqm105.0105.0293.04FalseNoneNoneFalseNoneFalse30769.20
3041252102757Nonecode17KSRB 8-8.54.1 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.(Item No. 8.54.1, Page No. 50, Vol.2)Sqm76.6576.65269.28FalseNoneNoneFalseNoneFalse20640.3120
3041253102757Nonecode18KSRB 11-11.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Item No. 11.6.1, Page No. 76, Vol.2)Sqm2764.652764.6529.25FalseNoneNoneFalseNoneFalse80866.01250
3041254102757Nonecode19KSRB 11-11.8.4:Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Item No. 11.8.4, Page No. 77, Vol.2)No25920.325920.32.0FalseNoneNoneFalseNoneFalse51840.60
3041255102757Nonecode20KSRB 11-11.35.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications..(Item No. 11.35.1.1, Page No. 87, Vol.2)Kg474.6474.6300.0FalseNoneNoneFalseNoneFalse142380.00
3041256102757Nonecode01Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fullyweather proofwith provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof lockingarrangements, with suitable size clamps with necessarycable entry pipe with gland and box should be finishedwith7tanks treatment withpowder coatedpaint and finally finished with approved colour etc., complete. PWD Ele SR 2-23-24 Page No 20 I No 5.42.2 16 SWGSq CM0.450.4543000.0FalseNoneNoneFalseNoneFalse19350.00
3041257102757Nonecode02SupplyingandfixingMouldedCaseCircuitBreaker(MCCB)overthe existing wood/panel board screws,bolts,nuts,necessaryphaseseparators,handleandwiringcomplete.ProtectionofOverloadandShort circuitwithadjustable the rmalmagneticrelease Microprocessorreleaseshallhave EarthFaultasperIS/IEC60947-2.(Icu=100%lcs). In4PMCCB, all Poles shouldhaveprotection forShort-Cicrcuit/OverLoad. ForMicroprocessorMCCBS Facility for segregatingPriorityandNon-Priorityloadsmust beavailable in theMCCB.MCCBshall beprovidedwithdouble insulation (insulationbetweenfrontcoverandinternalpowercircuitstoavoidanyaccidentalcontactwith live current carryingpathwith the front cover open) Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. PWD ELE SR 2023-24 Page No 17 I No 5.15.9 100 A 25 kA Four PoleEach8911.358911.351.0FalseNoneNoneFalseNoneFalse8911.350
3041258102757Nonecode03Aluminium Busbar/Wire Pieces. ESCOM SR 2023-24 Page No 33 I No 69.04Kg142.8142.80.5FalseNoneNoneFalseNoneFalse71.40
3041259102757Nonecode04Supplyingof Switchdisconnector fuse unit (TPN)HRC type (but without HRC fuses). With AC-23A duty and as per IS- 13947. PWD ELE SR PAGE NO 15 I NO : 5.8.1 63 AEach2427.62427.611.0FalseNoneNoneFalseNoneFalse26703.60
3041260102757Nonecode05Supplying and fixing HRC fuse units base on existing switch / panel board.PWD ELE SR PAGE NO 15 I NO : 5.9.2 32A TO 63 AEach642.6642.61.0FalseNoneNoneFalseNoneFalse642.60
3041261102757Nonecode06Supplying andfixingHRCfuselinkonexisting switchfusebasewith W loss as per IS-13703. PWD ELE SR PAGE NO 15 I NO : 5.10.1 upto 63 AEach305.55305.5511.0FalseNoneNoneFalseNoneFalse3361.050
3041262102757Nonecode07Supplying and fixing HRC fuse units base on existing switch / panel board.PWD ELE SR PAGE NO 15 I NO : 5.9.1 6A TO 16 AEach345.45345.4510.0FalseNoneNoneFalseNoneFalse3454.50
3041263102757Nonecode08SUB PANEL :Supplying&fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicatorON/OFF, energy cross-3 withShort circuitbreakingcapacity of 10 Kandcomplete wiring as required confirming to IEC60898 PWD ELE SR PAGE NO 17 I NO : 5.18.9 50-63 A TPNEach3242.43242.41.0FalseNoneNoneFalseNoneFalse3242.40
3041264102757Nonecode09Supplyingof Switchdisconnector fuse unit (TPN)HRC type (but without HRC fuses). With AC-23A duty and as per IS- 13947. PWD ELE SR PAGE NO 15 I NO : 5.8.1 63 AEach2427.62427.610.0FalseNoneNoneFalseNoneFalse24276.00
3041265102757Nonecode10Supplying and fixing HRC fuse units base on existing switch / panel board.PWD ELE SR PAGE NO 15 I NO : 5.9.2 32A TO 63 AEach642.6642.61.0FalseNoneNoneFalseNoneFalse642.60
3041266102757Nonecode11Supplying andfixingHRCfuselinkonexisting switchfusebasewith W loss as per IS-13703. PWD ELE SR PAGE NO 15 I NO : 5.10.1 upto 63 AEach305.55305.5510.0FalseNoneNoneFalseNoneFalse3055.50
3041267102757Nonecode12Outgoings: 32A Industrial socket-PWD ELE SR PAGE NO 9 I NO : 3.13.2Each575.48575.482.0FalseNoneNoneFalseNoneFalse1150.960
3041268102757Nonecode13Outgoings: 16A Industrial socket-PWD ELE SR PAGE NO 9 I NO : 3.13.1Each407.14407.142.0FalseNoneNoneFalseNoneFalse814.280
3041269102757Nonecode141.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 PWD Page No 13 I NO 32 50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm)Mtr187.92187.9230.0FalseNoneNoneFalseNoneFalse5637.60
3041270102757Nonecode1525 Sqmm, 4 Core, (13 GI Strips - 4 x 0.8 mm)Mtr188.83188.8320.0FalseNoneNoneFalseNoneFalse3776.60
3041271102757Nonecode1616 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm)Mtr148.93148.9320.0FalseNoneNoneFalseNoneFalse2978.60
3041272102757Nonecode1710 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm)Mtr123.9123.920.0FalseNoneNoneFalseNoneFalse2478.00
3041273102757Nonecode18Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 4Cx6.0 Sqmm Cu Ar cable ,3Cx6.0 Sqmm Cu Un Ar cable 3Cx 4.00 Sqmm ESCOM Page No 52 I NO 21.05Mtr21.9321.9350.0FalseNoneNoneFalseNoneFalse1096.50
3041274102757Nonecode19Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws. 19/20mm dia PVC 2mm thick conduit CSR Electrical SR-2023-24, ITEM NO:1.1.1 ,CH-1, PAGE NO-2Mtr72.4572.4510.0FalseNoneNoneFalseNoneFalse724.50
3041275102757Nonecode2025mm dia PVC 2mm thick conduit CSR Electrical SR-2023-24, ITEM NO:1.1.2 ,CH-1, PAGE NO-2Mtr85.0585.0510.0FalseNoneNoneFalseNoneFalse850.50
3041276102757Nonecode2132mm dia PVC 2mm thick conduit CSR Electrical SR-2023-24, ITEM NO:1.1.3 ,CH-1, PAGE NO-2Mtr111.3111.310.0FalseNoneNoneFalseNoneFalse1113.00
3041277102757Nonecode2240mm dia PVC 2mm thick conduit CSR Electrical SR-2023-24, ITEM NO:1.1.4 ,CH-1, PAGE NO-2Mtr156.45156.4510.0FalseNoneNoneFalseNoneFalse1564.50
3041278102757Nonecode23Supply & wiring from distribution board to looping switch boards. Laid wire size 2x2.5 Sqmm Ph-N & 1x1.5Sqmm for E for Lighting circuit wiring laid in existing conduit. 1.0 Sqmm Cu FRLS wire CSR Electrical SR-2023-24, ITEM NO:2.3.1 ,CH-1, PAGE NO-5Mtr19.9519.95300.0FalseNoneNoneFalseNoneFalse5985.00
3041279102757Nonecode241.5 Sqmm Cu FRLS wire CSR Electrical SR-2023-24, ITEM NO:2.3.2 ,CH-1, PAGE NO-5Mtr27.327.3300.0FalseNoneNoneFalseNoneFalse8190.00
3041280102757Nonecode252.5 Sqmm Cu FRLS wire CSR Electrical SR-2023-24, ITEM NO:2.3.3 ,CH-1, PAGE NO-5Mtr44.144.1300.0FalseNoneNoneFalseNoneFalse13230.00
3041281102757Nonecode264 Sqmm Cu FRLS wire CSR Electrical SR-2023-24, ITEM NO:2.3.4 ,CH-1, PAGE NO-5Mtr52.552.550.0FalseNoneNoneFalseNoneFalse2625.00
3041282102757Nonecode276 Sqmm Cu FRLS wire CSR Electrical SR-2023-24, ITEM NO:2.3.5 ,CH-1, PAGE NO-5Mtr52.552.51.0FalseNoneNoneFalseNoneFalse52.50
3041283102757Nonecode28Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit. 1 Light point upto 3Mtr from switch board CSR Electrical SR-2023-24, ITEM NO:2.1.1 ,CH-1, PAGE NO-5Nos299.25299.251.0FalseNoneNoneFalseNoneFalse299.250
3041284102757Nonecode291 Light point above 3M upto 6Mtr from switch board CSR Electrical SR-2023-24, ITEM NO:2.1.2 ,CH-1, PAGE NO-5Nos413.7413.71.0FalseNoneNoneFalseNoneFalse413.70
3041285102757Nonecode301 Light point above 6M upto 10Mtr from switch board CSR Electrical SR-2023-24, ITEM NO:2.1.3 ,CH-1, PAGE NO-5Nos598.5598.51.0FalseNoneNoneFalseNoneFalse598.50
3041286102757Nonecode312 Light point above 3Mtr upto 6Mtr from switch board CSR Electrical SR-2023-24, ITEM NO:2.1.4 ,CH-1, PAGE NO-5Nos743.4743.41.0FalseNoneNoneFalseNoneFalse743.40
3041287102757Nonecode322 Light point above 6Mtr upto 10Mtr from switch board CSR Electrical SR-2022-23, ITEM NO:2.1.4 ,CH-1, PAGE NO-5Nos757.05757.051.0FalseNoneNoneFalseNoneFalse757.050
3041288102757Nonecode333 Light point above 6Mtr upto 10Mtr from switch board CSR Electrical SR-2023-24, ITEM NO:2.1.5 ,CH-1, PAGE NO-5Nos1086.751086.753.0FalseNoneNoneFalseNoneFalse3260.250
3041289102757Nonecode34Switches & sockets outlets in Existing modular box 6A one way switch CSR Electrical SR-2023-24, ITEM NO:3.6.1 ,CH-3, PAGE NO-9Nos107.1107.14.0FalseNoneNoneFalseNoneFalse428.40
3041290102757Nonecode356A Three Way 5 Pin Socket CSR Electrical SR-2023-24, ITEM NO:3.14.3 ,CH-3, PAGE NO-10Nos73.573.52.0FalseNoneNoneFalseNoneFalse147.00
3041291102757Nonecode36Stepped fan regulator CSR Electrical SR-2023-24, ITEM NO:3.6.4 ,CH-3, PAGE NO-9Nos374.85374.852.0FalseNoneNoneFalseNoneFalse749.70
3041292102757Nonecode376/16A Universal socket CSR Electrical SR-2023-24, ITEM NO:3.6.11 ,CH-3, PAGE NO-5Nos247.8247.82.0FalseNoneNoneFalseNoneFalse495.60
3041293102757Nonecode38SupplyofLEDStreetlight luminairewithpressurediecastaluminium housing body for optimal thermal dissipation.Lamp compartment comprising ofanti glare clear diffuserwith Injectionmouldedpolycarbonatematerial, delivering superior light output Rated life Burning Hrs 50000 hr @Lumen Maintenanceof70%, maximumlightintensityshouldbebetween 60degrees to 70degrees. CCT greater than 5500K, IP66optical andelectrical compartment &impact resistanceof complete luminaire greater than IK08. Power Factor greater than 0.9 withmains,SurgeProtection-Min5KValongwithOver 40 W LED STREETLIGHTvoltage/Overload, short circuit/miss-wiring protection. Compatibleforpolemountingwithouterdiaof40mmto 50mm.UniversalVoltagedriver tooperatewidevoltage range from100Vto 270V50/60Hz application. Compliance to IS 10322/IEC60598,LM79& LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site locationwith minimized minimal tools. LED Light fixture with ........WSystem Power consumption. LED Efficiency greater than 1301m/w, nominal CRI greater than 75. Luminaire manufacturer should have in house facility accredited by NABL/CPRI any Government certified agency & Design & Development facility certified by ISO9001:2008. Housingwith supplierwordmark/name shallbe Engraved /Embossing on thediecast housing/Bodypart.Warrantyof2Yearsagainstanymanufacturindefectworkingunderstandardelectricalconditionsas mentioned above should be given by LEDmanufacturer &Cree/Nichia/Lumileds/Osram make LED Source CSR Electrical SR 2023 24, ITEM NO:11.8.2, PAGE NO 46Nos4225.24225.210.0FalseNoneNoneFalseNoneFalse42252.00
3041294102757Nonecode39Earthing: Providing and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. Volume - V Water supply SR 2023-24Job3937.53937.51.0FalseNoneNoneFalseNoneFalse3937.50
3041295102757Nonecode40Supplying & Laying cable trays including welding, fixing of supports Cable tray of 300 mm width (suitable for cable duct of D type) VOL-6 KPTCL PG NO 120 . I no 22Mtr791.7791.720.0FalseNoneNoneFalseNoneFalse15834.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17103282550000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17103282550000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17103282550000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneThe bidder should have executed the following quantity of items in any one continuous year the minimum quantities of work mentioned in Bid documentPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneTo qualify for award of this contract each tenderer in its name should have in the last five years (2018-19 to 2022-23) in any one year Satisfactorily completed as prime contractor at least one similar work such as of value not less than Rs 39.75 Lakhs (Certified Not less than the ranking of EE)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneTo qualify for award of this contract each tenderer in its name should have in the last five years i.e. 2018-19 to 2022-23 achieved in at least two financial years a minimum financial turnover (in all classes of civil engineering construction works only) of Rs 79.50 LakhsFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneTo qualify for award of this contract each tenderer further demonstrate Liquid assets and or availability of credit facilities of no less than Rs 23.85 Lakhs Credit lines/ letters of credit/ certificates from banks for meeting the fund requirement etcFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneGST RegistrationOthersRegistration
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneKPWD Contractor Registration CertificateOthersRegistration
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneIncome taxOthersIncome tax
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneITR Filed Copy (Mentioning PAN)
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Company Registration CertificateTrueTechnical Bid
Audited Balance sheet & Profit & Loss A/c .TrueTechnical Bid
GST Registration certificateTrueTechnical Bid
workdone certificateTrueTechnical Bid
Income Tax return filed.TrueTechnical Bid
Banker CertificateTrueTechnical Bid
qty wise workdone certificateTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone