1710329052000 | 1 | None | None | Water supply/sewage lines | A)Drilling of bore well and Cistern Construction at Netaji Nagar In Ward No 15 B do do at Kotta Pet Area, Timmapur Pet Area in Ward No 16 C do do at Jawahar Nagar, Tayi Nagar in Ward No 17 D do do at Manik Nagar, Kadargunda area in Ward No 18 E do do at Iqbal Nagar, Nawab Gadda area in Ward No 19 F)do do at Harijan Wada Area in Ward No 20 G do do at Devi Nagar, NGO Colony and Krishna Devaraya Colony in Ward No-21 Raichur City | 3509001.16 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3042316 | 102799 | None | code01 | Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test . | Each | 5552.4 | 5552.4 | 21.0 | False | None | None | False | None | False | 116600.4 | 0 | 3042317 | 102799 | None | code02 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) 0.00 To 50.00 Mtr | Mtr | 388.5 | 388.5 | 1050.0 | False | None | None | False | None | False | 407925.0 | 0 | 3042318 | 102799 | None | code03 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) 51.00 To 100.00 Mtr | Mtr | 487.2 | 487.2 | 1050.0 | False | None | None | False | None | False | 511560.0 | 0 | 3042319 | 102799 | None | code04 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) 100.00 To 150.00 Mtr | Mtr | 487.2 | 487.2 | 210.0 | False | None | None | False | None | False | 102312.0 | 0 | 3042320 | 102799 | None | code05 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for 160mm PVC Casing Pipe | Mtr | 648.9 | 648.9 | 252.0 | False | None | None | False | None | False | 163522.8 | 0 | 3042321 | 102799 | None | code06 | Providing, supplying to work site,Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications,with testing of as per instructions of engineer incharge of work and latest amendments 1.50 HP/1.1KW 26 STG | Each | 20380.5 | 20380.5 | 21.0 | False | None | None | False | None | False | 427990.5 | 0 | 3042322 | 102799 | None | code07 | Supply and delivery at site Brand new best make PVC insulated cable of
Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990
with ISI Mark and as per its latest amendments | Mtr | 194.25 | 194.25 | 630.0 | False | None | None | False | None | False | 122377.5 | 0 | 3042323 | 102799 | None | code08 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL Direct Online Starter 2) S-D- Star Delta Starter | Each | 7875.0 | 7875.0 | 21.0 | False | None | None | False | None | False | 165375.0 | 0 | 3042324 | 102799 | None | code09 | Labour charges for providing connection using insulated sheathed steel wire cable as per IS 1554 1988 with latest amendments from KPTCL pole to meter board unit, with all necessary materials ,tools and equipments,as per specificationswith testing of as per instructions of engineer incharge of work.3 6 sqmm | Rmtr | 168.0 | 168.0 | 210.0 | False | None | None | False | None | False | 35280.0 | 0 | 3042325 | 102799 | None | code10 | Supply and delivery at site brand new best make pressure guage suitable
for centrifugal pump confirming to latest IS standards. pressure guage 80MM | Each | 626.85 | 626.85 | 21.0 | False | None | None | False | None | False | 13163.85 | 0 | 3042326 | 102799 | None | code11 | Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPTCL authorities and erection, electrification and commissioning of the same at the location of respective pump sets | Kvar | 577.5 | 577.5 | 21.0 | False | None | None | False | None | False | 12127.5 | 0 | 3042327 | 102799 | None | code12 | Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC
Column pipes with heavy duty collars,rubber profile ring,vibration
control profile ring,freezing and turbulence free leak proof EPDM ring
with ISI mark with its latest amendments | Mtr | 577.5 | 577.5 | 735.0 | False | None | None | False | None | False | 424462.5 | 0 | 3042328 | 102799 | None | code13 | Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments 50mm dia | No | 1312.5 | 1312.5 | 21.0 | False | None | None | False | None | False | 27562.5 | 0 | 3042329 | 102799 | None | code14 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work | Job | 6825.0 | 6825.0 | 21.0 | False | None | None | False | None | False | 143325.0 | 0 | 3042330 | 102799 | None | code15 | Labour charges for erection of outdoor type panel board and meter board units with all necessary materials and labour, tools and equipments including providing cement concrete foundation bed etc., complete as per specification, with testing of as per instructions of engineer incharge of work | Each | 1522.5 | 1522.5 | 21.0 | False | None | None | False | None | False | 31972.5 | 0 | 3042331 | 102799 | None | code16 | RCC hume pipe Circular pump house: Providing precast RCC Circular
Hume pipe pump house with M.S door and RCC conical roof as per
specification and drawings - Internal dia Mtr. 1200 mm & height of 2.5
Mtr. With Wall thickness 65mm etc. complete. | Each | 17221.05 | 17221.05 | 21.0 | False | None | None | False | None | False | 361642.05 | 0 | 3042332 | 102799 | None | code17 | Erection and positioning of RCC Hume pipe pump house/Cistern on
size stone masory platform including transportation charges and
handling,finishing with all necessary tools ,plants and materials
etc.,complete as directed by the Engineer in charge of work | Each | 1976.1 | 1976.1 | 21.0 | False | None | None | False | None | False | 41498.1 | 0 | 3042333 | 102799 | None | code18 | Earth work excavation by manual means for drains, canals, waste weir, draft,
approach channels, key trenches, foundation of Buildings & bridges and such
simillar works in all kinds of soils, as per drawing and technical specifications,
including setting out, shoring, strutting, barricading, caution lights, removal
of stumps and other deleterious matter, excavated surface leveled and sides
neatly dressed disposing off the excavated stuff or sorting & stacking the
selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of
labour, tools & other appurtenaces required to complete the work. | Cum | 254.1 | 254.1 | 23.66 | False | None | None | False | None | False | 6012.006 | 0 | 3042334 | 102799 | None | code19 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of
machinery, curing, and all the other appurtenances required to complete the
work as per technical specifications | Cum | 6288.45 | 6288.45 | 4.76 | False | None | None | False | None | False | 29933.022 | 0 | 3042335 | 102799 | None | code20 | Providing Random rubble masonry with hard stone in foundation and
plinth including levelling up with cement concrete 1:6:12 (1 cement : 6
coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth
level with :Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5891.55 | 5891.55 | 14.21 | False | None | None | False | None | False | 83718.9255 | 0 | 3042336 | 102799 | None | code21 | Providing Size Stone masonry with hard stone in foundation & plinth with
Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 23.201 | False | None | None | False | None | False | 155642.74845 | 0 | 3042337 | 102799 | None | code22 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of
machinery, curing, and all the other appurtenances required to complete the
work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6555.15 | 6555.15 | 7.07 | False | None | None | False | None | False | 46344.9105 | 0 | 3042338 | 102799 | None | code23 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to
brick/stone masonry including rounding off corners wherever required
smooth rendering, providing and removing scaffolding, including cost of
materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 349.65 | 349.65 | 63.0 | False | None | None | False | None | False | 22027.95 | 0 | 3042339 | 102799 | None | code24 | Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990
with latest amendments complete with GI fittings (excluding the cost
of fittings) with cuts and threads wherever necessary, including testing
for water tightness, with all lead and commissioning. (contractor will
make his own arrangements for procuring water for testing) For:Heavy
Duty GI Pipe etc. complete Heavy Duty GI pipe of 32mm dia | Mtr | 449.4 | 449.4 | 126.0 | False | None | None | False | None | False | 56624.4 | 0 |
|