1710325967000 | 1 | None | None | Buildings | Construction of Anganwadi Center-1 at Malgatti Village in Kalaburagi Taluka under KKRDB for the year 2022-23 | 1270579.5 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3039495 | 102644 | None | 001 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) for Column Footing | Cum | 6676.56 | 6676.56 | 3.28 | False | None | None | False | None | False | 21899.1168 | 0 | 3039496 | 102644 | None | 002 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) for Columns | Cum | 10818.5 | 10818.5 | 3.54 | False | None | None | False | None | False | 38297.49 | 0 | 3039497 | 102644 | None | 003 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) for Chajja | Cum | 9273.0 | 9273.0 | 0.53 | False | None | None | False | None | False | 4914.69 | 0 | 3039498 | 102644 | None | 004 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) for Plinth beam | Cum | 9582.1 | 9582.1 | 2.97 | False | None | None | False | None | False | 28458.837 | 0 | 3039499 | 102644 | None | 005 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) for Roof Beam | Cum | 10200.3 | 10200.3 | 5.24 | False | None | None | False | None | False | 53449.572 | 0 | 3039500 | 102644 | None | 006 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) for Slab | Cum | 9582.1 | 9582.1 | 24.56 | False | None | None | False | None | False | 235336.376 | 0 | 3039501 | 102644 | None | 007 | Providing Thermo-Mechanically Treated Bars Of Grade Fe-500d Or More Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position, Binding And Anchoring To Adjacent Members Whereever Necessary Complete As Per Design Including Cost Of Material, Labour, Usage Charges Complete As Per Specifications. (The Laps And Wastages Shall Not Be Measured Separately) | Kgs | 87.15 | 87.15 | 3683.74 | False | None | None | False | None | False | 321037.941 | 0 | 3039502 | 102644 | None | 008 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work | Cum | 7024.5 | 7024.5 | 30.15 | False | None | None | False | None | False | 211788.675 | 0 | 3039503 | 102644 | None | 009 | Providing 12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 223.65 | 223.65 | 339.42 | False | None | None | False | None | False | 75911.283 | 0 | 3039504 | 102644 | None | 010 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kgs | 154.35 | 154.35 | 223.02 | False | None | None | False | None | False | 34423.137 | 0 | 3039505 | 102644 | None | 011 | Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. | Sqm | 1022.7 | 1022.7 | 23.43 | False | None | None | False | None | False | 23961.861 | 0 | 3039506 | 102644 | None | 012 | Flooring with 25mm thick polished shahabad slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. | Sqm | 1377.6 | 1377.6 | 45.32 | False | None | None | False | None | False | 62432.832 | 0 | 3039507 | 102644 | None | 013 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 110.25 | 110.25 | 162.03 | False | None | None | False | None | False | 17863.8075 | 0 | 3039508 | 102644 | None | 014 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 69.3 | 69.3 | 109.69 | False | None | None | False | None | False | 7601.517 | 0 | 3039509 | 102644 | None | 015 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 43.05 | 43.05 | 45.36 | False | None | None | False | None | False | 1952.748 | 0 | 3039510 | 102644 | None | 016 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m over an under coat of primer applied @0.75 ltr/10 m of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 110.25 | 110.25 | 45.36 | False | None | None | False | None | False | 5000.94 | 0 | 3039511 | 102644 | None | 017 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 38.85 | 38.85 | 22.68 | False | None | None | False | None | False | 881.118 | 0 | 3039512 | 102644 | None | 018 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 94.5 | 94.5 | 22.68 | False | None | None | False | None | False | 2143.26 | 0 | 3039513 | 102644 | None | 019 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. | Sqm | 498.75 | 498.75 | 11.4 | False | None | None | False | None | False | 5685.75 | 0 | 3039514 | 102644 | None | 020 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. | Sqm | 2998.8 | 2998.8 | 3.15 | False | None | None | False | None | False | 9446.22 | 0 | 3039515 | 102644 | None | 021 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2 including pointing in white cement mixed with pigment of matching shade complete. | Sqm | 660.45 | 660.45 | 2.22 | False | None | None | False | None | False | 1466.199 | 0 | 3039516 | 102644 | None | 022 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. | Ltr | 8.4 | 8.4 | 500.0 | False | None | None | False | None | False | 4200.0 | 0 | 3039517 | 102644 | None | 023 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/e fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge Concealed work, including cutting chases and making good the walls etc. | Mtr | 321.3 | 321.3 | 10.0 | False | None | None | False | None | False | 3213.0 | 0 | 3039518 | 102644 | None | 024 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/e fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge Concealed work, including cutting chases and making good the walls etc. | Mtr | 391.65 | 391.65 | 10.0 | False | None | None | False | None | False | 3916.5 | 0 | 3039519 | 102644 | None | 025 | Providing and fixing brass bib cock of approved quality with all lead, lifts, loading & unloading charges, Transportation Charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Nos | 362.25 | 362.25 | 3.0 | False | None | None | False | None | False | 1086.75 | 0 | 3039520 | 102644 | None | 026 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) | Each | 554.4 | 554.4 | 1.0 | False | None | None | False | None | False | 554.4 | 0 | 3039521 | 102644 | None | 027 | Providing and fixing white vitreous china water closet squatting pan (Indian type) : Long Pattern W.C. Pan of size 580mm | Nos | 1210.65 | 1210.65 | 1.0 | False | None | None | False | None | False | 1210.65 | 0 | 3039522 | 102644 | None | 028 | Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67:2012 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick or Aluminium composite material sheet with overall thickness of 4mm with area not exceeding 0.9 m2 fixed over back support frame of min 35 x 35 x 3mm angle mounted on a mild steel circular pipe 65 NB, firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing | Sqm | 8471.4 | 8471.4 | 0.81 | False | None | None | False | None | False | 6861.834 | 0 | 3039523 | 102644 | None | 029 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and runningbefore concreting the slab. The conduit should be tied to thereinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered usingPVC end enclosures, run with 18SWG GI fish wire wherever necessary 25mm dia 2mm thick | Mtr | 61.0 | 61.0 | 120.0 | False | None | None | False | None | False | 7320.0 | 0 | 3039524 | 102644 | None | 030 | Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25mm dia 2mm thick | Mtr | 80.0 | 80.0 | 120.0 | False | None | None | False | None | False | 9600.0 | 0 | 3039525 | 102644 | None | 031 | Supplying and fixing PVC/metal conduit Deep junction box 25mm deep junction box | Mtr | 51.0 | 51.0 | 4.0 | False | None | None | False | None | False | 204.0 | 0 | 3039526 | 102644 | None | 032 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete 10"x7"x3" (254x178x76mm) with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Nos | 77.0 | 77.0 | 5.0 | False | None | None | False | None | False | 385.0 | 0 | 3039527 | 102644 | None | 033 | Supplying And Fixing Metal Fan Box with Round Hook. with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Nos | 163.0 | 163.0 | 2.0 | False | None | None | False | None | False | 326.0 | 0 | 3039528 | 102644 | None | 034 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3Mtr from tapping point to out let via switch with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Nos | 276.0 | 276.0 | 4.0 | False | None | None | False | None | False | 1104.0 | 0 | 3039529 | 102644 | None | 035 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Nos | 386.0 | 386.0 | 6.0 | False | None | None | False | None | False | 2316.0 | 0 | 3039530 | 102644 | None | 036 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Long point above 6Mtr upto 10Mtr from tapping point to out let via switch with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Nos | 567.0 | 567.0 | 6.0 | False | None | None | False | None | False | 3402.0 | 0 | 3039531 | 102644 | None | 037 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS:8130-1984 and (Virgin) PVC insulation sheathed suitabl 3C X 1.5Sq.mm with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Mtr | 69.0 | 69.0 | 120.0 | False | None | None | False | None | False | 8280.0 | 0 | 3039532 | 102644 | None | 038 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS:8130-1984 and (Virgin) PVC insulation sheathed suitabl 4C X 1.5Sq.mm with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Mtr | 88.0 | 88.0 | 120.0 | False | None | None | False | None | False | 10560.0 | 0 | 3039533 | 102644 | None | 039 | Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6Amps 2 Way with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Each | 121.0 | 121.0 | 4.0 | False | None | None | False | None | False | 484.0 | 0 | 3039534 | 102644 | None | 040 | Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board.6Amps 2way Switch with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Nos | 59.0 | 59.0 | 4.0 | False | None | None | False | None | False | 236.0 | 0 | 3039535 | 102644 | None | 041 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.1 to 3 Module with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Each | 152.0 | 152.0 | 20.0 | False | None | None | False | None | False | 3040.0 | 0 | 3039536 | 102644 | None | 042 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.6 Module with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Each | 244.0 | 244.0 | 10.0 | False | None | None | False | None | False | 2440.0 | 0 | 3039537 | 102644 | None | 043 | Supplying and fixing hylum plastic sheet 3mm thick with necessary nitches for fixing switches, regulators etc., and fixing on existing wood or metal box using N.F. screws. with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Sq CM | 0.29 | 0.29 | 70000.0 | False | None | None | False | None | False | 20300.0 | 0 | 3039538 | 102644 | None | 044 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Each | 2170.0 | 2170.0 | 2.0 | False | None | None | False | None | False | 4340.0 | 0 | 3039539 | 102644 | None | 045 | Fixing all types and all capacities of fluorescent / false ceiling/ spot light / CFL / LED fittings indoor on the wall / ceiling /rafters / girders using 23/0.0076” twin twisted PVC insulatedwires, required Nos of round blocks and clamps. with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Each | 119.0 | 119.0 | 6.0 | False | None | None | False | None | False | 714.0 | 0 | 3039540 | 102644 | None | 046 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Each | 162.0 | 162.0 | 2.0 | False | None | None | False | None | False | 324.0 | 0 | 3039541 | 102644 | None | 047 | Supplying and fixing regular MCB distribution boards on wall/ wood board / flush mounting using required clamps, bolts,nuts etc., with provision for fixing suitable type capacityMCB's single phase / 3 phase / single door with powdercoated painting. Made out of 14 SWG MS enclosure. with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Each | 3735.0 | 3735.0 | 2.0 | False | None | None | False | None | False | 7470.0 | 0 | 3039542 | 102644 | None | 048 | Supplying and fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materialsand 'C' Type curve, indicator ON/OFF, energy cross-3 withShort circuit breaking capacity of 10K and complete wiringas required confirming to IEC 60898. with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Each | 532.0 | 532.0 | 1.0 | False | None | None | False | None | False | 532.0 | 0 | 3039543 | 102644 | None | 049 | Supplying and fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materialsand 'C' Type curve, indicator ON/OFF, energy cross-3 withShort circuit breaking capacity of 10K and complete wiringas required confirming to IEC 60898. with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Each | 1103.0 | 1103.0 | 2.0 | False | None | None | False | None | False | 2206.0 | 0 |
|