3012898 | 100636 | None | code01 | Demolishing R.C.C. work manually by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineerincharge | Cum | 1950.9 | 1950.9 | 0.3802 | False | None | None | False | None | False | 741.73218 | 0 |
3012899 | 100636 | None | code02 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid inlayers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technicalspecifications. The cost of steel reinforcement, dowel bars & formwork to be paid separately M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6491.1 | 6491.1 | 21.8821 | False | None | None | False | None | False | 142038.89931 | 0 |
3012900 | 100636 | None | code03 | Formwork for CenteringColumns FOR RCC | Sqm | 4543.77 | 4543.77 | 4.122 | False | None | None | False | None | False | 18729.41994 | 0 |
3012901 | 100636 | None | code04 | Formwork for Centering Beams and Lintel FOR RCC | Sqm | 3894.66 | 3894.66 | 3.0098 | False | None | None | False | None | False | 11722.147668 | 0 |
3012902 | 100636 | None | code05 | Formwork for Centering for Roof FOR RCC | Sqm | 3245.55 | 3245.55 | 14.7507 | False | None | None | False | None | False | 47874.134385 | 0 |
3012903 | 100636 | None | code06 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1 6 1 cement 1 6 coarse sand including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work.It no 6.8 P no 14 v 2. | Cum | 7024.5 | 7024.5 | 25.6413 | False | None | None | False | None | False | 180117.31185 | 0 |
3012904 | 100636 | None | code07 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. ncluding priming coat with approved steel primer all complete. Fixed to steel windows by welding P NO 85, It no 11.34A | Sqm | 152.25 | 152.25 | 573.3 | False | None | None | False | None | False | 87284.925 | 0 |
3012905 | 100636 | None | code08 | Providing 12 mm cement plaster with cement mortar 1 6 1 cement 6 fine sand including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost ofmaterials, labour, curing complete as per specifications and as per directions of Engineer in charge.v 2,8.1.2 | Sqm | 207.9 | 207.9 | 211.425 | False | None | None | False | None | False | 43955.2575 | 0 |
3012906 | 100636 | None | code09 | Providing 15 mm cement plaster on External walls on the rough side of single or half brick wall of mix 16 1 cement 6 fine sand including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per
specifications and as per directions of Engineerincharge.v2,8.2.2 | Sqm | 241.5 | 241.5 | 155.26 | False | None | None | False | None | False | 37495.29 | 0 |
3012907 | 100636 | None | code10 | Supplying, Fitting and Placing TMT Fe 550 and above Reinforcement in Foundation Substructure Superstructure complete as per Drawing and Technical Specifications. It no 9.3 P no 71, V3 | Tonne | 84311.85 | 84311.85 | 1.907 | False | None | None | False | None | False | 160782.69795 | 0 |
3012908 | 100636 | None | code11 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops
and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge PWD SR VOL2 IT NO 8.39 | Sqm | 99.75 | 99.75 | 211.42 | False | None | None | False | None | False | 21089.145 | 0 |
3012909 | 100636 | None | code12 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. E.R.W. tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge.Vol2 SR 202122, It.No.11.26.2, P.No.7 | Kg | 122.85 | 122.85 | 238.14 | False | None | None | False | None | False | 29255.499 | 0 |
3012910 | 100636 | None | code13 | Supplying heavy gauge PVC conduit pipe 20mm dia 2 mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.PWD Ele SR-2021-22 [P-1 I NO-1.1.1]19/20 mm dia 2 mm thick | Mtr | 68.0 | 68.0 | 140.0 | False | None | None | False | None | False | 9520.0 | 0 |
3012911 | 100636 | None | code14 | Supplying & fixing retrofit type PL LED Lamp W LED linear source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to275 V. Tested by NABL CPRI accredited laboratory with 2 years
Warranty against any manufacturing defect working under standard electrical condition.PWD Ele SR-202122 P 1 I NO-11.2..2 18 20 W | Each | 691.0 | 691.0 | 16.0 | False | None | None | False | None | False | 11056.0 | 0 |
3012912 | 100636 | None | code15 | Wiring for lightingpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS 694 confirming to latest amendments 1.5 mm2. 2.3.2 pwd sr 2022 23 1.5 mm2 | Mtr | 26.0 | 26.0 | 140.0 | False | None | None | False | None | False | 3640.0 | 0 |
3012913 | 100636 | None | code16 | Wiring for lightingpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694 confirming to latest amendments. p, no 3 I no 2.3.3 PWD Part 1 SR 2021 22 2.5 mm2 | Mtr | 40.0 | 40.0 | 120.0 | False | None | None | False | None | False | 4800.0 | 0 |
3012914 | 100636 | None | code17 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C curve , indicator ONOFF, energy cross 3 with Short circuit breaking capacity of 10K and complete wiring as required Confirming to IEC 60898 PWD Part 1 SR 2021 22 | Each | 1103.0 | 1103.0 | 2.0 | False | None | None | False | None | False | 2206.0 | 0 |
3012915 | 100636 | None | code18 | Supplying and flush mounting powder coated galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick Stone C.C wall.PWD Ele SR 2021 22 P 5 I NO 3.4.4 8 Way | Each | 250.0 | 250.0 | 10.0 | False | None | None | False | None | False | 2500.0 | 0 |
3012916 | 100636 | None | code19 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal PVC box.PWD Ele SR 2021 22 P 5 I NO 3.5.4 8 Module | Each | 302.0 | 302.0 | 10.0 | False | None | None | False | None | False | 3020.0 | 0 |
3012917 | 100636 | None | code20A | Supplying and wiring adopting loop system in existing PVC Conduit casing capping casing capping using 2x1.5mm2 Phase and Neutral and 1x1.0 mm2 Earth wire FRLS multi strand PVC insulated copper wire confirming to IS 694 and latest amendments without control switch shall be fixed on the existing plastic sheet gang box, the other end of the wires shall be terminated with sufficient loose length in a wood PVC round block. complete for each outlet. PWD Common SR 2021 22 Page No 3 Item No 2.2.Short point upto 3m tapping point to out let via switch box page no 3 item no 2.2.1 | Point | 251.0 | 251.0 | 8.0 | False | None | None | False | None | False | 2008.0 | 0 |
3012918 | 100636 | None | code20B | Supplying and wiring adopting loop system in existing PVC Conduit casing capping casing capping using 2x1.5mm2 Phase & Neutral & 1x1.0 mm2 Earth wire FRLS multi strand PVC insulated copper wire confirming to IS 694 and latest amendments without control switch shall be fixed on the existing plastic sheet gang box, the other end of the wires shall be terminated with sufficient loose length in a woodPVC round block. complete for each outlet. PWD Common SR 2021 22 Page No 3 Item No 2.2 Short point above 3m upto 6m tapping point to out let via switch box page no 3 item no 2.2.2 | Point | 361.0 | 361.0 | 8.0 | False | None | None | False | None | False | 2888.0 | 0 |
3012919 | 100636 | None | code21A | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. PWD Common SR 2021 22 Page No 5 Item No 3.6 6A one way switch page no 5 item no 3.6.1 | Each | 88.0 | 88.0 | 8.0 | False | None | None | False | None | False | 704.0 | 0 |
3012920 | 100636 | None | code21B | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. PWD Common SR 2021 22 Page No 5 Item No 3.6 6A Three way socket page no 5 item no 3.6.3 | Each | 162.0 | 162.0 | 8.0 | False | None | None | False | None | False | 1296.0 | 0 |
3012921 | 100636 | None | code22 | Supplying wall mounting fan suitable to operate at single phase 230v A.C Supply 400mm sweep | Each | 2838.0 | 2838.0 | 8.0 | False | None | None | False | None | False | 22704.0 | 0 |