1709633182000 | 0 | None | None | Buildings | Construction of physically challenged handicap toilet building and library building at Hagribommanahalli town limits | 5276729.4 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2920238 | 96192 | None | HBH001 | Earth work in surface excavation for stripping, seating of bund, Road way by manual means for lowering and levelling the ground for all works other than foundation and depth in Ordinary rock and soft rock upto 300mm depth as per drawing and technical specifications, including setting out, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting and stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5m including cost of labour, tools, usageand other appurtenances required to complete the work.(PWD SR 2023-24, VOLUME-1, Page No. 5, SI No. 1.2) | Cum | 603.75 | 603.75 | 102.0 | False | None | None | False | None | False | 61582.5 | 0 | 2920239 | 96192 | None | HBH002 | Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery and other appurtenaces required to complete the work - In all kinds of soils Depth upto 3 m (PWD SR 2023-24, VOLUME-1, Page No. 8, SI No. 1.14.1) | Cum | 107.1 | 107.1 | 221.21 | False | None | None | False | None | False | 23691.591 | 0 | 2920240 | 96192 | None | HBH003 | Providing and fixing 25mm diameter steel anchor dowel in hard rock including drilling hole of 32 mm diameter up to 0.75 mtrs depth, placing the dowel in position and effectively grouting the hole with CM 1 1 proportion etc. complete. (PWD SR 2023-24, VOLUME-3, Page No. 159, SI No. 17B. 1. | Nos | 1312.5 | 1312.5 | 24.0 | False | None | None | False | None | False | 31500.0 | 0 | 2920241 | 96192 | None | HBH004 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1 4 8 Using 40 mm nominal size graded crushed coarse aggregates (PWD SR 2023-24, VOLUME-1, Page No. 15, SI No.2.1.2) | Cum | 5947.2 | 5947.2 | 21.26 | False | None | None | False | None | False | 126437.472 | 0 | 2920242 | 96192 | None | HBH005 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1 4 8 Using 40 mm nominal size graded crushed coarse aggregates (PWD SR 2023-24, VOLUME-1, Page No. 15, SI No.2.1.2) | Cum | 6125.62 | 6125.62 | 15.12 | False | None | None | False | None | False | 92619.3744 | 0 | 2920243 | 96192 | None | HBH006 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. .Mix 1 3 6 Using 20 mm nominal size graded crushed coarse aggregates (PWD Common Sr- 2023-24. Vol-1. Page no 15,Item No 2.1.4) | Cum | 6527.85 | 6527.85 | 3.04 | False | None | None | False | None | False | 19844.664 | 0 | 2920244 | 96192 | None | HBH007 | Providing Size Stone masonry with hard stone in foundation and plinth with Cement mortar 1 6 (1 cement 6 coarse sand) (PWD SR 2023-24, VOLUME-2, Page No. 9, SI No. 5.4) | Cum | 6708.45 | 6708.45 | 15.28 | False | None | None | False | None | False | 102505.116 | 0 | 2920245 | 96192 | None | HBH008 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1 6 12 (1 cement 6 coarse sand 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1 6 (1 cement 6 coarse sand) (PWD Common Sr- 2023-24. Vol-1 . Page no 9.Item No 5.1.1) | Cum | 5891.55 | 5891.55 | 22.12 | False | None | None | False | None | False | 130321.086 | 0 | 2920246 | 96192 | None | HBH009 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.(PWD SR 2023-24, VOLUME-1, Page No. 7, SI No.1.9) | Cum | 279.3 | 279.3 | 153.9 | False | None | None | False | None | False | 42984.27 | 0 | 2920247 | 96192 | None | HBH010 | Refilling available Earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications (PWD Common Sr- 2021-22. Vol-1 . Page no 7.Item No 1.10) | Cum | 168.0 | 168.0 | 38.04 | False | None | None | False | None | False | 6390.72 | 0 | 2920248 | 96192 | None | HBH011 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (PWDSR 2023-24 Page No 7, Item No 1.11) | Cum | 454.65 | 454.65 | 72.44 | False | None | None | False | None | False | 32934.846 | 0 | 2920249 | 96192 | None | HBH012 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. .(PWD Common Sr- 2023-24. Vol-1 . Page no 15.Item No 2.2.1) | Cum | 6799.39 | 6799.39 | 7.2 | False | None | None | False | None | False | 48955.608 | 0 | 2920250 | 96192 | None | HBH013 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead and lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD SR 2023-24, VOLUME-1, Page No. 16, SI No.2.4.2) | Cum | 7170.28 | 7170.28 | 20.38 | False | None | None | False | None | False | 146130.3064 | 0 | 2920251 | 96192 | None | HBH014 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead and lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications..(PWD Common Sr- 2023-24. Vol-1 . Page no 16.Item No 2.4.3) | Cum | 11309.76 | 11309.76 | 2.08 | False | None | None | False | None | False | 23524.3008 | 0 | 2920252 | 96192 | None | HBH015 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead and lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications..(PWD Common Sr- 2023-24. Vol-1 . Page no 16.Item No 2.4.3) | Cum | 9979.2 | 9979.2 | 5.04 | False | None | None | False | None | False | 50295.168 | 0 | 2920253 | 96192 | None | HBH016 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (PWD Common Sr- 2023-24. Vol-1 . Page no 16.Item No 2.5.2) | Cum | 12214.76 | 12214.76 | 3.56 | False | None | None | False | None | False | 43484.5456 | 0 | 2920254 | 96192 | None | HBH017 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (PWD Common Sr- 2023-24. Vol-1 . Page no 16.Item No 2.5.2) | Cum | 10777.73 | 10777.73 | 1.52 | False | None | None | False | None | False | 16382.1496 | 0 | 2920255 | 96192 | None | HBH018 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (PWD Common Sr- 2023-24. Vol-1 . Page no 16.Item No 2.5.2) | Cum | 10418.47 | 10418.47 | 0.64 | False | None | None | False | None | False | 6667.8208 | 0 | 2920256 | 96192 | None | HBH019 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (PWD Common Sr- 2023-24. Vol-1 . Page no 16.Item No 2.5.2) | Cum | 11496.24 | 11496.24 | 0.76 | False | None | None | False | None | False | 8737.1424 | 0 | 2920257 | 96192 | None | HBH020 | Providing and laying in position Cement Concrete for all Super structures of building, Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD SR 2021-22, VOLUME-1, Page No. 16, SI No.2.5.1) | Cum | 11834.55 | 11834.55 | 7.63 | False | None | None | False | None | False | 90297.6165 | 0 | 2920258 | 96192 | None | HBH021 | Providing and laying in position Cement Concrete for all Super structures of building, Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD SR 2021-22, VOLUME-1, Page No. 16, SI No.2.5.1) | Cum | 10442.25 | 10442.25 | 31.33 | False | None | None | False | None | False | 327155.6925 | 0 | 2920259 | 96192 | None | HBH022 | Providing and laying in position Cement Concrete for all Super structures of building, Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD SR 2021-22, VOLUME-1, Page No. 16, SI No.2.5.1) | Cum | 11138.4 | 11138.4 | 10.54 | False | None | None | False | None | False | 117398.736 | 0 | 2920260 | 96192 | None | HBH023 | Providing and laying in position Cement Concrete for all Super structures of building, Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD SR 2021-22, VOLUME-1, Page No. 16, SI No.2.5.1) | Cum | 10094.18 | 10094.18 | 0.71 | False | None | None | False | None | False | 7166.8678 | 0 | 2920261 | 96192 | None | HBH024 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (PWD SR 2023-24, VOLUME-1, Page No. 18, SI No.2.11 a ) | Tonne | 93929.85 | 93929.85 | 7.99 | False | None | None | False | None | False | 750499.5015 | 0 | 2920262 | 96192 | None | HBH025 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1 4 as per IS 2572 2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (PWD SR 2023-24, VOLUME-2, Page No. 17, SI No.6.32) | Sqm | 1375.5 | 1375.5 | 172.88 | False | None | None | False | None | False | 237796.44 | 0 | 2920263 | 96192 | None | HBH026 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1 6 (1 cement 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work..(PWD Common Sr- 2023-24. Vol-2 . Page no 14,Item No 6.8.) | Cum | 8367.45 | 8367.45 | 31.68 | False | None | None | False | None | False | 265080.816 | 0 | 2920264 | 96192 | None | HBH027 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1 4 (1cement 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work..(PWD Common Sr- 2023-24. Vol-2 . Page no 14, Item No 6.13) | Sqm | 1024.8 | 1024.8 | 57.2 | False | None | None | False | None | False | 58618.56 | 0 | 2920265 | 96192 | None | HBH028 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Electric resistance or induction butt welded tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge(PWD Common Sr- 2023-24. Vol-2 . Page no 83, Item No 11.16.3) | Kgs | 128.1 | 128.1 | 568.48 | False | None | None | False | None | False | 72822.288 | 0 | 2920266 | 96192 | None | HBH029 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (Plus 0.05 percent) total coated thickness with zinc coating 120 g/m2 as per IS 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5 x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (PWD Common Sr- 2023-24. Vol-2 . Page no 26, Item No 7.38) | Sqm | 596.4 | 596.4 | 69.44 | False | None | None | False | None | False | 41414.016 | 0 | 2920267 | 96192 | None | HBH030 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (Plus0.05 percent) total coated thickness, Zinc coating 120 g/m2 as per IS 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete . Ridges plain (500 - 600mm) (PWD Common Sr- 2023-24. Vol-2 . Page no 26, Item No 7.39.1) | Rmtr | 473.55 | 473.55 | 12.4 | False | None | None | False | None | False | 5872.02 | 0 | 2920268 | 96192 | None | HBH031 | Providing Honne wood frames of doors, windows, clerestory windows,ventilators and other frames, wrought, framed or assembled includingmaking plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (PWD SR 2023-24, VOLUME-2, Page No. 99, SI No.12.11) | Cum | 144977.7 | 144977.7 | 0.19 | False | None | None | False | None | False | 27545.763 | 0 | 2920269 | 96192 | None | HBH032 | Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures )(PWD SR 2023-24, VOLUME-2, Page No. 100, SI No.12.17) | Sqm | 7439.25 | 7439.25 | 4.32 | False | None | None | False | None | False | 32137.56 | 0 | 2920270 | 96192 | None | HBH033 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (PWD SR 2023-24, VOLUME 2- Page No.100 , SI No. 12.13.1) | Cum | 103755.75 | 103755.75 | 0.45 | False | None | None | False | None | False | 46690.0875 | 0 | 2920271 | 96192 | None | HBH034 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-do- 30 mm thick Both side teak (PWD SR 2023-24, VOLUME 2- Page No.105 , SI No. 12.57.1) | Sqm | 4245.15 | 4245.15 | 14.4 | False | None | None | False | None | False | 61130.16 | 0 | 2920272 | 96192 | None | HBH035 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in Charge.(PWD Vol-2 Common Sr- 2023-24 .Page No 77, Item No 11.5.1) | Sqm | 4701.9 | 4701.9 | 20.16 | False | None | None | False | None | False | 94790.304 | 0 | 2920273 | 96192 | None | HBH036 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1 3 6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. (PWD SR 2023-24, VOLUME 2- Page No.104 , SI No. 12.51) | Nos | 1066.8 | 1066.8 | 7.0 | False | None | None | False | None | False | 7467.6 | 0 | 2920274 | 96192 | None | HBH037 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete (PWD SR 2023-24, VOLUME 2- Page No.105 , SI No. 12.62) | Each | 248.85 | 248.85 | 14.0 | False | None | None | False | None | False | 3483.9 | 0 | 2920275 | 96192 | None | HBH038 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete 100x10mm (PWD SR 2023-24, VOLUME 2- Page No.107 , SI No. 12.76.4) | Each | 206.85 | 206.85 | 14.0 | False | None | None | False | None | False | 2895.9 | 0 | 2920276 | 96192 | None | HBH039 | Providing and fixing IS 12817 marked stainless steel butt hinges with stainless steel screws etc. complete 100x58x1.9mm (PWD SR 2023-24, VOLUME 2- Page No.107 , SI No. 12.74.2) | Each | 95.55 | 95.55 | 28.0 | False | None | None | False | None | False | 2675.4 | 0 | 2920277 | 96192 | None | HBH040 | Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete. (PWD SR 2023-24, VOLUME 2- Page No.105 , SI No. 12.61) | Each | 1039.5 | 1039.5 | 14.0 | False | None | None | False | None | False | 14553.0 | 0 | 2920278 | 96192 | None | HBH041 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding (PWD SR 2023-24, VOLUME 2- Page No.86 , SI No. 11.34A) | Kgs | 176.4 | 176.4 | 715.56 | False | None | None | False | None | False | 126224.784 | 0 | 2920279 | 96192 | None | HBH042 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(PWD Common Sr- 2023-24. Vol-2 .Page no 84,Item No 11.26.1. ) | Kgs | 144.9 | 144.9 | 176.64 | False | None | None | False | None | False | 25595.136 | 0 | 2920280 | 96192 | None | HBH043 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions
of Engineer-in-charge. (PWD SR 2023-24, VOLUME 2- Page No.48 , SI No.8.41) | Sqm | 175.35 | 175.35 | 56.16 | False | None | None | False | None | False | 9847.656 | 0 | 2920281 | 96192 | None | HBH044 | Providing and fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardwareand single point locking system with touch lock. Wall thickness of frame and sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor TandPs shall not be made)(PWD SR 2023-24, VOLUME 2- Page No.110 , SI No.12.89) | Sqm | 6878.55 | 6878.55 | 21.6 | False | None | None | False | None | False | 148576.68 | 0 | 2920282 | 96192 | None | HBH045 | Providing and fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor TandPs shall not be made)(PWD SR 2023-24, VOLUME 2- Page No.109 , SI No.12.85) | Sqm | 6004.95 | 6004.95 | 3.36 | False | None | None | False | None | False | 20176.632 | 0 | 2920283 | 96192 | None | HBH046 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 percent and conforming to I.S. 15622, of approved make, in all colours and shade, over 12 mm thick bed of cement mortar 1 3 (1 cement 3 coarse sand), jointing with grey cement slurry at 3.3 kg/ m2 including grouting the joint with white cement and matching pigments etc. complete. Size of Tile 600x600 mm (PWD SR 2023-24, VOLUME 2- Page No.61 , SI No.9.17.2) | Sqm | 1233.75 | 1233.75 | 148.33 | False | None | None | False | None | False | 183002.1375 | 0 | 2920284 | 96192 | None | HBH047 | Providing and laying Vitrified tiles with thickness 9-10 mm in floor with different sizes with water absorption less than 0.08percent and conforming to IS 15622, of approved brand and manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm (PWD Vol-2 Common Sr-2023-2024.Page No 62.Item No 9.21.2) | Sqm | 1299.9 | 1299.9 | 72.6 | False | None | None | False | None | False | 94372.74 | 0 | 2920285 | 96192 | None | HBH048 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1 4 (1 Cement 4 Coarse sand), Jointing with grey cement slurry at 3.3 kg/m2 includ- ing pointing the joints with white cement and matching pigment etc., complete(PWD Vol-2 Common Sr-2021-2022.Page No 60.Item No 9.9) | Sqm | 1129.8 | 1129.8 | 31.68 | False | None | None | False | None | False | 35792.064 | 0 | 2920286 | 96192 | None | HBH049 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1 3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. (PWD SR 2023-24, VOLUME 2- Page No.65 , SI No.9.39) | Sqm | 1521.45 | 1521.45 | 44.73 | False | None | None | False | None | False | 68054.4585 | 0 | 2920287 | 96192 | None | HBH050 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1 6, 20 mm thick, and joints finished with cement mortar 1 3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. (PWD SR 2023-24, VOLUME 2- Page No.64 , SI No.9.30) | Sqm | 5594.4 | 5594.4 | 6.83 | False | None | None | False | None | False | 38209.752 | 0 | 2920288 | 96192 | None | HBH051 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1 4 (1 cement 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.(PWD SR 2023-24, VOLUME 2- Page No.69 , SI No.10.1.1) | Sqm | 4206.3 | 4206.3 | 7.2 | False | None | None | False | None | False | 30285.36 | 0 | 2920289 | 96192 | None | HBH052 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1 5 (1 cement 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1 6 (1 cement 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(PWD SR 2023-24, VOLUME 2- Page No.42 ,SI 8.8 ) | Sqm | 389.55 | 389.55 | 262.39 | False | None | None | False | None | False | 102214.0245 | 0 | 2920290 | 96192 | None | HBH053 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1 4 (1 cement 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR 2023-24, VOLUME 2- Page No.41 ,SI 8.2.1) | Sqm | 309.75 | 309.75 | 486.4 | False | None | None | False | None | False | 150662.4 | 0 | 2920291 | 96192 | None | HBH054 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1 6 (1 cement 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(PWD Common Sr- 2023-24. Vol-2 .Page no 41,Item No 8.2.2.) | Sqm | 292.95 | 292.95 | 471.92 | False | None | None | False | None | False | 138248.964 | 0 | 2920292 | 96192 | None | HBH055 | Finishing walls with Acrylic Smooth exterior paint of required shade New work (Two coat applied at 1.67 ltr/10 m² over and including priming coat of exterior primer applied at 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(PWD SR 2023-24, VOLUME 2- Page No.46 ,SI 8.30) | Sqm | 182.7 | 182.7 | 262.39 | False | None | None | False | None | False | 47938.653 | 0 | 2920293 | 96192 | None | HBH056 | Finishing walls with water proofing cement paint of required shade New work (Two coats applied at 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge(PWD Common Sr- 2023-24. Vol-2 . Page no 45,Item No 8.28) | Sqm | 93.45 | 93.45 | 440.24 | False | None | None | False | None | False | 41140.428 | 0 | 2920294 | 96192 | None | HBH057 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(PWD SR 2023-24, VOLUME 2- Page No.48 ,SI 8.39) | Sqm | 133.35 | 133.35 | 580.88 | False | None | None | False | None | False | 77460.348 | 0 | 2920295 | 96192 | None | HBH058 | Painting Steel work Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(PWD Common Sr- 2023-24. Vol-2 .Page no 48,Item No 8.40. ) | Sqm | 120.75 | 120.75 | 57.72 | False | None | None | False | None | False | 6969.69 | 0 | 2920296 | 96192 | None | HBH059 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3.On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.
4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry
surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and
melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) (PWD SR 2023-24, VOLUME 2- Page No.54-55 ,SI 8.82) | Sqm | 710.85 | 710.85 | 10.8 | False | None | None | False | None | False | 7677.18 | 0 | 2920297 | 96192 | None | HBH060 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied at 0.90 ltr/10 m² over an under coat of primer applied at0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(PWD SR 2021-22, VOLUME 2- Page No.46 ,SI 8.33.2) | Sqm | 144.9 | 144.9 | 36.0 | False | None | None | False | None | False | 5216.4 | 0 | 2920298 | 96192 | None | HBH061 | Finishing walls with textured exterior paint of required shade New work (Two coats applied at 3.28 ltr/10 m²) over and including priming coat of exterior primer applied at 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(PWD SR 2023-24, VOLUME 2- Page No.45-46 , SI No.8.29) | Sqm | 371.44 | 371.44 | 113.64 | False | None | None | False | None | False | 42210.4416 | 0 | 2920299 | 96192 | None | HBH062 | Supplying heavy gauge PVC conduit pipe mm dia mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2 mm thick 1.2.1 | Rmtr | 69.3 | 69.3 | 290.0 | False | None | None | False | None | False | 20097.0 | 0 | 2920300 | 96192 | None | HBH063 | Supplying heavy gauge PVC conduit pipe mm dia mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25 mm dia 2 mm thick 1.2.2 | Rmtr | 81.9 | 81.9 | 140.0 | False | None | None | False | None | False | 11466.0 | 0 | 2920301 | 96192 | None | HBH064 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 75 x 75 x 65 mm 1.4.1 | Each | 106.0 | 106.0 | 26.0 | False | None | None | False | None | False | 2756.0 | 0 | 2920302 | 96192 | None | HBH065 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 100 x 75 x 65 mm 1.4.2 | Each | 118.0 | 118.0 | 18.0 | False | None | None | False | None | False | 2124.0 | 0 | 2920303 | 96192 | None | HBH066 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 180 x 90 x 65 mm 1.4.4 | Each | 161.0 | 161.0 | 18.0 | False | None | None | False | None | False | 2898.0 | 0 | 2920304 | 96192 | None | HBH067 | Supplying and fixing PVC/metal conduit Deep junction box 19/20 mm deep Junction box 1.5.1 | Each | 49.0 | 49.0 | 22.0 | False | None | None | False | None | False | 1078.0 | 0 | 2920305 | 96192 | None | HBH068 | Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction box 1.5.2 | Each | 56.0 | 56.0 | 12.0 | False | None | None | False | None | False | 672.0 | 0 | 2920306 | 96192 | None | HBH069 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. upto 50 mm conduit in brick wall 1.7.1 | Rmtr | 29.0 | 29.0 | 146.0 | False | None | None | False | None | False | 4234.0 | 0 | 2920307 | 96192 | None | HBH070 | Supplying And Fixing Metal Fan Box with Round Hook 1.13 | Each | 117.0 | 117.0 | 15.0 | False | None | None | False | None | False | 1755.0 | 0 | 2920308 | 96192 | None | HBH071 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase and Neutral) and 1x1.0 mm 2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694 and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3m from tapping point to out let via switch box 2.2.1 | Each | 269.0 | 269.0 | 68.0 | False | None | None | False | None | False | 18292.0 | 0 | 2920309 | 96192 | None | HBH072 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase and Neutral) and 1x1.0 mm 2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694 and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3m upto 6m from tapping point to out let via switch box 2.2.2 | Each | 379.0 | 379.0 | 38.0 | False | None | None | False | None | False | 14402.0 | 0 | 2920310 | 96192 | None | HBH073 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694 confirming to latest amendments 1.5 mm2 2.3.2 | Rmtr | 26.0 | 26.0 | 620.0 | False | None | None | False | None | False | 16120.0 | 0 | 2920311 | 96192 | None | HBH074 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694 confirming to latest amendments 2.5 mm2 2.3.3 | Rmtr | 42.0 | 42.0 | 420.0 | False | None | None | False | None | False | 17640.0 | 0 | 2920312 | 96192 | None | HBH075 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 1 to 3 Module 3.5.1 | Each | 137.0 | 137.0 | 15.0 | False | None | None | False | None | False | 2055.0 | 0 | 2920313 | 96192 | None | HBH076 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 3Module 3.5.2 | Each | 161.0 | 161.0 | 8.0 | False | None | None | False | None | False | 1288.0 | 0 | 2920314 | 96192 | None | HBH077 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 4 Module 3.5.3 | Each | 175.0 | 175.0 | 15.0 | False | None | None | False | None | False | 2625.0 | 0 | 2920315 | 96192 | None | HBH078 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 6 Module 3.5.4 | Each | 234.0 | 234.0 | 15.0 | False | None | None | False | None | False | 3510.0 | 0 | 2920316 | 96192 | None | HBH079 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 8 Module 3.5.5 | Each | 284.0 | 284.0 | 8.0 | False | None | None | False | None | False | 2272.0 | 0 | 2920317 | 96192 | None | HBH080 | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch 3.6.1 | Each | 102.0 | 102.0 | 46.0 | False | None | None | False | None | False | 4692.0 | 0 | 2920318 | 96192 | None | HBH081 | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two Module 3.6.4 | Each | 357.0 | 357.0 | 30.0 | False | None | None | False | None | False | 10710.0 | 0 | 2920319 | 96192 | None | HBH082 | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16A One Way Switch 3.6.7 | Each | 180.0 | 180.0 | 34.0 | False | None | None | False | None | False | 6120.0 | 0 | 2920320 | 96192 | None | HBH083 | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16A Universal Socket 3.6.10 | Each | 236.0 | 236.0 | 44.0 | False | None | None | False | None | False | 10384.0 | 0 | 2920321 | 96192 | None | HBH084 | Supplying and fixing 32A security and energy saving DP switch with key tag suitable to operate on 230 V, 50Hz AC supply and completely wired on existing box 3.7 | Each | 646.0 | 646.0 | 8.0 | False | None | None | False | None | False | 5168.0 | 0 | 2920322 | 96192 | None | HBH085 | Supplying and fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers 32 A 5.7.2 | Each | 241.0 | 241.0 | 24.0 | False | None | None | False | None | False | 5784.0 | 0 | 2920323 | 96192 | None | HBH086 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP 5.18.1 | Each | 415.0 | 415.0 | 12.0 | False | None | None | False | None | False | 4980.0 | 0 | 2920324 | 96192 | None | HBH087 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. II - Double Door 8 Way SP and N 5.19.8 | Each | 1854.0 | 1854.0 | 8.0 | False | None | None | False | None | False | 14832.0 | 0 | 2920325 | 96192 | None | HBH088 | Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 A three phase 4 wire whole current class-1 Accuracy Energy Meter 5.35 | Each | 5705.0 | 5705.0 | 1.0 | False | None | None | False | None | False | 5705.0 | 0 | 2920326 | 96192 | None | HBH089 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia 12.57 | Job | 4256.0 | 4256.0 | 5.0 | False | None | None | False | None | False | 21280.0 | 0 | 2920327 | 96192 | None | HBH090 | Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete 12" Sweep (300 mm) 6.2.1 | Each | 2969.0 | 2969.0 | 2.0 | False | None | None | False | None | False | 5938.0 | 0 | 2920328 | 96192 | None | HBH091 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts,50 cycles. Single phase AC supply conforming to ISS-3741979 and with double ball bearing system. 48" Sweep (1200mm) Regular model 6.4.1 | Each | 2984.0 | 2984.0 | 14.0 | False | None | None | False | None | False | 41776.0 | 0 | 2920329 | 96192 | None | HBH092 | Supplying of feet -PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours and 70percent lumen maintenance with CRI greater than 80. Power Input 220-240Vat 50/60Hz and Power factor greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 W 11.3.1 | Each | 551.0 | 551.0 | 20.0 | False | None | None | False | None | False | 11020.0 | 0 | 2920330 | 96192 | None | HBH093 | Supplying of feet -PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours and 70percent lumen maintenance with CRI greater than 80. Power Input 220-240Vat 50/60Hz and Power factor greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 W 11.3.2 | Each | 690.0 | 690.0 | 16.0 | False | None | None | False | None | False | 11040.0 | 0 | 2920331 | 96192 | None | HBH094 | Supplying and fixing of 5'-80 W of T8 Fluorescent Tube with 54W power consumption with low 3mg Mercury content less phosphor coating Operating voltage range from 180V to 265V, 50Hz AC power Supply12.21 | Each | 520.0 | 520.0 | 10.0 | False | None | None | False | None | False | 5200.0 | 0 | 2920332 | 96192 | None | HBH095 | Supplying and Fixing of 70-150 W lamp holder 2 Pin 12.47 | Each | 148.0 | 148.0 | 20.0 | False | None | None | False | None | False | 2960.0 | 0 | 2920333 | 96192 | None | HBH096 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. On wall/ ceiling / Rafter / Girders 13.7.1 | Each | 122.0 | 122.0 | 64.0 | False | None | None | False | None | False | 7808.0 | 0 | 2920334 | 96192 | None | HBH097 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS 8931 13.12 | Each | 666.75 | 666.75 | 20.0 | False | None | None | False | None | False | 13335.0 | 0 | 2920335 | 96192 | None | HBH098 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS 893 13.15 | Each | 761.25 | 761.25 | 10.0 | False | None | None | False | None | False | 7612.5 | 0 | 2920336 | 96192 | None | HBH099 | Providing and fixing brass bib cock of approved quality 20mm nominal bore 13.2.2 | Each | 320.25 | 320.25 | 8.0 | False | None | None | False | None | False | 2562.0 | 0 | 2920337 | 96192 | None | HBH100 | Providing and fixing in position brass PUSH cock of approved quality 20mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. (In Hand Wash) DR | Each | 310.8 | 310.8 | 8.0 | False | None | None | False | None | False | 2486.4 | 0 | 2920338 | 96192 | None | HBH101 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 15 mm nominal bore 13.5.1 | Each | 310.8 | 310.8 | 10.0 | False | None | None | False | None | False | 3108.0 | 0 | 2920339 | 96192 | None | HBH102 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 25 mm nominal bore 13.4.1 | Each | 576.45 | 576.45 | 5.0 | False | None | None | False | None | False | 2882.25 | 0 | 2920340 | 96192 | None | HBH103 | Providing and fixing unplasticised PVC connection pipe with brass unions 15mm nominal bore 13.8.1.1 | Each | 87.15 | 87.15 | 8.0 | False | None | None | False | None | False | 697.2 | 0 | 2920341 | 96192 | None | HBH104 | Providing and fixing unplasticised PVC connection pipe with brass unions 20 mm nominal bore 13.8.1.2 | Each | 95.55 | 95.55 | 5.0 | False | None | None | False | None | False | 477.75 | 0 | 2920342 | 96192 | None | HBH105 | Providing and fixing chorinated poly veny chloride (CPVC) pipes, having therminal stability for hot and cold water supply, including all cPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 m C/C spacing. This includes jointing of pipe and fittings with one step Cpvc solvent cement and testing of joints complete as per direction of engineer in charge.(Internal work exposed on walls) 20mm OD Pipe 13.31.2 | Each | 254.1 | 254.1 | 75.0 | False | None | None | False | None | False | 19057.5 | 0 | 2920343 | 96192 | None | HBH106 | Providing and fixing chorinated poly veny chloride (CPVC) pipes, having therminal stability for hot and cold water supply, including all cPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 m C/C spacing. This includes jointing of pipe and fittings with one step Cpvc solvent cement and testing of joints complete as per direction of engineer in charge.(Internal work exposed on walls) 25mm OD Pipe 13.31.3 | Each | 333.9 | 333.9 | 75.0 | False | None | None | False | None | False | 25042.5 | 0 | 2920344 | 96192 | None | HBH107 | Providing and fixing chorinated poly veny chloride (CPVC) pipes, having therminal stability for hot and cold water supply, including all cPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 m C/C spacing. This includes jointing of pipe and fittings with one step Cpvc solvent cement and testing of joints complete as per direction of engineer in charge.(Internal work exposed on walls) 20mm OD Pipe 13.32.2 | Each | 397.95 | 397.95 | 40.0 | False | None | None | False | None | False | 15918.0 | 0 | 2920345 | 96192 | None | HBH108 | Providing and fixing chorinated poly veny chloride (CPVC) pipes, having therminal stability for hot and cold water supply, including all cPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 m C/C spacing. This includes jointing of pipe and fittings with one step Cpvc solvent cement and testing of joints complete as per direction of engineer in charge.(Internal work exposed on walls) 25mm OD Pipe 13.32.3 | Each | 500.85 | 500.85 | 32.0 | False | None | None | False | None | False | 16027.2 | 0 | 2920346 | 96192 | None | HBH109 | Providing and fixing chorinated poly veny chloride (CPVC) pipes, having therminal stability for hot and cold water supply, including all cPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 m C/C spacing. This includes jointing of pipe and fittings with one step Cpvc solvent cement and testing of joints complete as per direction of engineer in charge.(Internal work exposed on walls) 25mm OD Pipe 13.33.3 | Each | 310.8 | 310.8 | 40.0 | False | None | None | False | None | False | 12432.0 | 0 | 2920347 | 96192 | None | HBH110 | Providing and fixing chorinated poly veny chloride (CPVC) pipes, having therminal stability for hot and cold water supply, including all cPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 m C/C spacing. This includes jointing of pipe and fittings with one step Cpvc solvent cement and testing of joints complete as per direction of engineer in charge.(Internal work exposed on walls) 32mm OD Pipe 13.32.4 | Each | 390.6 | 390.6 | 40.0 | False | None | None | False | None | False | 15624.0 | 0 | 2920348 | 96192 | None | HBH111 | Providing and placing on terrace, polyethylene water storage tanks, IS 12701 marked, with cover and suitable locking arrangements, making necessary holes for inlet, outlet and over flow pipes but without fittings and the base support for tank 13.34 | Ltr | 9.45 | 9.45 | 3000.0 | False | None | None | False | None | False | 28350.0 | 0 | 2920349 | 96192 | None | HBH112 | Providing and fixing vitreous china dual purpose closet suitable for use as squatting pan or European type water closet (Anglo Indian W.C pan) with seat and lid fixed with C.P. brass hinges and rubber buffers, 10 litre low level flushing cistern with fitting and brackets, 40 mm flush bend, 20 mm over flow pipe, with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required White vitreous china dual purpose WC pan with white solid plastic seat and lid with white vitreous china flushing cistern and C.P. flush bend. 14.35.1 | Each | 9063.6 | 9063.6 | 2.0 | False | None | None | False | None | False | 18127.2 | 0 | 2920350 | 96192 | None | HBH113 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern and C.P. flush bend with fittings and C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required W.C. pan with ISI marked black solid plastic seat and lid 14.2.2 | Each | 5076.75 | 5076.75 | 8.0 | False | None | None | False | None | False | 40614.0 | 0 | 2920351 | 96192 | None | HBH114 | White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps 14.7.1 | Each | 3236.1 | 3236.1 | 2.0 | False | None | None | False | None | False | 6472.2 | 0 | 2920352 | 96192 | None | HBH115 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require White Vitreous China Flat back wash basin size 450x 300 mm with single 15mm C.P. brass pillar tap 14.7.7 | Each | 2203.95 | 2203.95 | 8.0 | False | None | None | False | None | False | 17631.6 | 0 | 2920353 | 96192 | None | HBH116 | Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. 2 HP, Size 65x50 Head 13M, Discharge 462 LPM V-5
13.14.1 | Each | 16390.5 | 16390.5 | 1.0 | False | None | None | False | None | False | 16390.5 | 0 | 2920354 | 96192 | None | HBH117 | Supplying and erection of RCC rings for well steining of 0.3 Mtr Depth using M-20 grade concrete using clean graded granite or trap or jelly of approved quality 20mm and down size well compacted including centering, from work and plastering for both faces with C.M 1 3 proportion as per design using 6.50mm M.S. coil at the rate of 10 Kgs/ring including cost of steel and fabrication, bailing out of water, errection etc., complete iii) For 1.20 M dia (clear) rings of steining thickness 0.075 M upto 18 M depth RWS SR 2019-20 Zone-B | Each | 1097.25 | 1097.25 | 20.0 | False | None | None | False | None | False | 21945.0 | 0 | 2920355 | 96192 | None | HBH118 | Providing and laying 100mm thick pre-cast cover slabs over drains and Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel at 2.00 kg/m2, slabs jointed in CM 1 3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Vol. II/ 17.12 | Sqm | 974.4 | 974.4 | 7.08 | False | None | None | False | None | False | 6898.752 | 0 |
|