createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1710139292902
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee810.00
emd65000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose27-03-2024 16:00:00
tenderQueryClose25-03-2024 16:00:00
technicalBidOpen28-03-2024 17:00:00
publishedDate11-03-2024 17:37:08
publishedByPostIDD_EE_DIV_KWR
publishedByUserKPE12286 - M V PRASAD
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonThippeswamy M R
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08382229672
mobileNumberNone
tenderSupplierListNone
tenderSchedule
createdTs1710139292949
version4
createdDateNone
modifiedDateNone
tenderNumberIDD/2023-24/BD/WORK_INDENT40
titleConstruction of Toilet and Bathroom Building fot Gents and Ladies Fisherman at Belekeri fishery harbour in Ankola Taluka of Uttar Kannada district
descriptionConstruction of Toilet and Bathroom Building fot Gents and Ladies Fisherman at Belekeri fishery harbour in Ankola Taluka of Uttar Kannada district
categoryWORKS
categoryTextWorks
ecv3231241.88
deptNameInfrastructure Development Ports And Inland Water Transport Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location5468
locationNameExecutive engineer Karwar
provisionalAmount4200000.0
groupOverheadTotal0.0
fileNumber02-AEE/PSD/KWR/TCH/DOF/BELKR/BNT/EST/2023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17101392930000NoneNoneBuildingsConstruction of Toilet and Bathroom Building fot Gents and Ladies Fisherman at Belekeri fishery harbour in Ankola Talika of Uttar Kannada district3231241.88
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
298412598977None1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m (UNI SOR 2023-24 Vol-1, page. no. 5, Item no. 1.4.1)Cum271.04271.0453.97FalseNoneNoneFalseNoneFalse14628.02880
298412698977None1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (UNI SOR 2023-24 Vol-1, page no. 7, Item no. 1.9)Cum297.92297.9278.06FalseNoneNoneFalseNoneFalse23255.63520
298412798977None2.1.4Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M 10) Using 40 mm nominal size graded crushed coarse aggregates (UNI SOR 2023-24 Vol-1 page 15, sl. no. 2.1.4)Cum6963.046963.0419.52FalseNoneNoneFalseNoneFalse135918.54080
298412898977None2.2.5Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (UNI SOR 2023-24 Vol-1, page. no. 15, Item no. 2.2.5)Cum7497.257497.256.9FalseNoneNoneFalseNoneFalse51731.0250
298412998977None2.2.5Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (UNI SOR 2023-24 Vol-1, page. no. 15, Item no. 2.2.5) Cum12374.112374.10.94FalseNoneNoneFalseNoneFalse11631.6540
298413098977None2.3.3Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (UNI SOR 2023-24 Vol-1, page. no. 16, Item no. 2.3.3) Cum11096.411096.44.93FalseNoneNoneFalseNoneFalse54705.2520
298413198977None2.5.3Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (UNI SOR 2023-24 Vol-1, page. no. 16, Item no. 2.5.3)Cum12556.5412556.5419.99FalseNoneNoneFalseNoneFalse251005.23460
298413298977None2.52Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (UNI SOR 2023-24 volume-1, page no. 17, Item no.2.5.2)Cum11113.0311113.031.74FalseNoneNoneFalseNoneFalse19336.67220
298413398977None2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (The laps and wastages shall not be measured separately) (UNI SOR 2023-24 Vol-1 page.no.84, sl. no.2.11 a )t100191.84100191.842.75FalseNoneNoneFalseNoneFalse275527.560
298413498977None5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (UNI SOR 2023-24 Vol-2, page. No.9, sl. No. 5.4)Cum7155.687155.6814.25FalseNoneNoneFalseNoneFalse101968.440
298413598977None5.7Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6. (UNI SOR 2023-24 Vol-2, page no 9 sl. No. 5.7)Cum7565.67565.627.99FalseNoneNoneFalseNoneFalse211761.1440
298413698977None6.13Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. (UNI SOR 2023-24 Vol-2, page. No.14, sl. No. 6.13)Sqm1093.121093.12104.94FalseNoneNoneFalseNoneFalse114712.01280
298413798977None12.12Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications (UNI SOR 2023-24 Vol-2, page. No.99, sl. No. 12.12) Cum139106.24139106.240.76FalseNoneNoneFalseNoneFalse105720.74240
298413898977None12.15Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ) (UNI SOR 2023-24 Vol-2, page. No.100, sl. No.12.15)Sqm8337.288337.283.78FalseNoneNoneFalseNoneFalse31514.91840
298413998977None12.55.1Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. (UNI SOR 2023-24 Vol-2, page No.104, sl. No.12.55.1). Sqm2649.922649.9231.5FalseNoneNoneFalseNoneFalse83472.480
298414098977None11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding (UNI SOR 2023-24 Vol-2, page No.86, sl. No.11.34A)Kgs188.16188.16124.74FalseNoneNoneFalseNoneFalse23471.07840
298414198977None8.4.1Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (UNI SOR 2023-24 Vol-2, page No.41, sl.No.8.4.1)Sqm361.76361.7683.18FalseNoneNoneFalseNoneFalse30091.19680
298414298977None8.3.1Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (UNI SOR 2023-24 Vol-2, page No.41, sl.No.8.3.1). Sqm396.48396.48209.54FalseNoneNoneFalseNoneFalse83078.41920
298414398977None9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. (UNI SOR 2023-24 Vol-2, page No.60 sl.No.9.11).Sqm995.68995.6855.17FalseNoneNoneFalseNoneFalse54931.66560
298414498977None9.17Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.(UNI SOR 2023-24 Vol-2, page No.61 sl.No.9.17).Sqm1245.441245.44306.45FalseNoneNoneFalseNoneFalse381665.0880
298414598977None15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU wa terproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the wa terproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. (UNI SOR 2023-24 Vol-2, page No.149 sl.No.15.1)Sqm915.04915.0484.64FalseNoneNoneFalseNoneFalse77448.98560
298414698977None8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (UNI SOR 2023-24 Vol-2, page No.50 sl.No.8.51)Sqm112.0112.0393.06FalseNoneNoneFalseNoneFalse44022.720
298414798977None8.25Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(UNI SOR 2023-24 Vol-2, page No.45 sl.No.8.25)Sqm153.44153.4483.18FalseNoneNoneFalseNoneFalse12763.13920
298414898977None8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.s (UNI SOR 2023-24 Vol-2, page No.45 sl.No.8.29)Sqm316.96316.96209.54FalseNoneNoneFalseNoneFalse66415.79840
298414998977None8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (UNI SOR 2023-24 Vol-2, page No.47 sl.No.8.34.1)Sqm59.3659.3610.0FalseNoneNoneFalseNoneFalse593.60
298415098977None8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(UNI SOR 2023-24 Vol-2, page No.48 sl.No.8.41)Sqm187.04187.0421.0FalseNoneNoneFalseNoneFalse3927.840
298415198977None001Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete. (internal work exposed on wall) - 20mm nominal OD pipes.(UNI SOR 2023-24 Vol-2, page No.122 sl.No.13.31.2) m271.04271.0426.6FalseNoneNoneFalseNoneFalse7209.6640
298415298977None002Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete. (internal work exposed on wall) - 25mm nominal OD pipes.(UNI SOR 2023-24 Vol-2, page No.122 sl.No.13.31.3) m356.16356.1613.7FalseNoneNoneFalseNoneFalse4879.3920
298415398977None003Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete. (internal work exposed on wall) - 32mm nominal OD pipes.(UNI SOR 2023-24 Vol-2, page No.122 sl.No.13.31.4) m448.0448.041.46FalseNoneNoneFalseNoneFalse18574.080
298415498977None004Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) (UNI SOR 2023-24 Volume-2, page No.117 sl.No.13.3.2) Nos669.76669.7620.0FalseNoneNoneFalseNoneFalse13395.20
298415598977None005Providing and fixing brass stop cock of approved quality : (UNI SOR 2023-24 Vol-2, page No.117 sl.No.13.3.2) Nos341.6341.614.0FalseNoneNoneFalseNoneFalse4782.40
298415698977None14.40600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. each 380.0 (UNI SOR Vol-2, page No.137 sl.No.14.40.2) Each555.52555.528.0FalseNoneNoneFalseNoneFalse4444.160
298415798977None14.32.4Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing (UNI SOR 2023-24 Vol-2, page No.136 sl.No.14.32.4) Each1933.121933.124.0FalseNoneNoneFalseNoneFalse7732.480
298415898977None13.2Providing and fixing brass bib cock of approved quality 15mm (UNI SOR 2023-24 Vol-2, page No.117 sl.No.13.2) No320.32320.3216.0FalseNoneNoneFalseNoneFalse5125.120
298415998977None14.25Providing and fixing white vitreous china wash basin including making all connections but including the cost of fittings :(UNI SOR 2023-24 Vol-2, page No.129 sl.No.14.25.1) Each1104.321104.324.0FalseNoneNoneFalseNoneFalse4417.280
298416098977None13.87Providing and fixing Chlorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings this includes jointing of pipes and fittings with one steps solvent cement, trenching, refilling & testing of joints complete (external work) 100mm nominal OD Pipe (UNI SOR 2023-24 Vol-2, page No.123 sl.No.13.33.9) m2826.882826.8835.0FalseNoneNoneFalseNoneFalse98940.80
298416198977None007Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. (external work). - 150mm nominal OD pipes (UNI SOR 2023-24 Vol-2, page No.123 sl.No.13.33.10) m5942.725942.7221.0FalseNoneNoneFalseNoneFalse124797.120
298416298977None13.22.2Providing and fixing PTMT grating of approved quality and colour Rectangular type with openable circular lid.(UNI SOR 2023-24 Vol-2, page No.120 sl.No.13.22.2)Nos226.24226.2417.0FalseNoneNoneFalseNoneFalse3846.080
298416398977None14.5.1Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required Single half stall urinal with 5 litre P.V.C. automatic flushing cistern :(UNI SOR 2023-24 Vol-2, page No.123 sl.No.14.5.1) Each9679.049679.043.0FalseNoneNoneFalseNoneFalse29037.120
298416498977None14.29Providing and fixing 100 mm sand cast Iron grating for gully trap (UNI SOR 2023-24 Vol-2, page No.136 sl.No.14.29) Each52.6452.642.0FalseNoneNoneFalseNoneFalse105.280
298416598977None13.53Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 (UNI SOR 2023-24 Vol-2, page No.126 sl.No.13.53) Each Set6319.046319.043.0FalseNoneNoneFalseNoneFalse18957.120
298416698977None12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. (UNI SOR 2023-24 Volume-2, page No.104, sl.No.12.51)Each1137.921137.9217.0FalseNoneNoneFalseNoneFalse19344.640
298416798977None13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.:(UNI SOR 2023-24 Vol-2, page No.123 sl.No.13.34) l10.0810.084000.0FalseNoneNoneFalseNoneFalse40320.00
298416898977None13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter (UNI SOR 2023-24 Vol-2, page No.125 sl.No.13.48) m325.92325.9222.8FalseNoneNoneFalseNoneFalse7430.9760
298416998977None2.5.3Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (UNI SOR 2023-24 Vol-1, page. no. 16, Item no. 2.5.3) Cum13341.3313341.332.15FalseNoneNoneFalseNoneFalse28683.85950
298417098977None8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(UNI SOR 2023-24 Vol-2, page No.42, sl.No.8.5.2). Sqm390.88390.88306.45FalseNoneNoneFalseNoneFalse119785.1760
298417198977None8.27Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(UNI SOR 2023-24 Vol-2, page No.45 sl.No.8.27) Sqm59.3659.36393.06FalseNoneNoneFalseNoneFalse23332.04160
298417298977None8.28Finishing inner walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(UNI SOR 2023-24 Vol-2, page No.45 sl.No.8.28) Sqm99.6899.68308.42FalseNoneNoneFalseNoneFalse30743.30560
298417398977None12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)(UNI SOR 2023-24 Vol-5, page No.139 sl.No.12.1)Borewell depth of 50 to 100 Mtrs m519.68519.6820.0FalseNoneNoneFalseNoneFalse10393.60
298417498977None13.8.5Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments)(UNI SOR 2023-24 Vol-5, page No.150 sl.No.13.8.5)2.00 HP/1.5KW 15 STG Each20404.1620404.161.0FalseNoneNoneFalseNoneFalse20404.160
298417598977None13.23.1Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete.(UNI SOR 2023-24 Vol-5, page No.155 sl.No.13.23.1)Upto 3 HP pumps Each7280.07280.01.0FalseNoneNoneFalseNoneFalse7280.00
298417698977None14.7Supply and laying of LG UT cable having aluminium conductor PVC insulated, sheathed, galvanized steel wire / steel tap armored cable with PVC over sheathing.(UNI SOR 2023-24 Vol-5, page No.176 sl.No.14.7) m89.689.630.0FalseNoneNoneFalseNoneFalse2688.00
298417798977None990Unplasticised P.V.C.connection pipe with brass union 45 cm long20 mm bore uPVC Pipes 100 mm nominal dia.(UNI SOR 2023-24 Vol-2, page No.A42 sl.No.990) m530.88530.8830.0FalseNoneNoneFalseNoneFalse15926.40
298417898977None13.31.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 50 mm nominal dia Pipes .(UNI SOR 2023-24 Vol-2, page No.122 sl.No.13.31.6) m874.72874.7230.0FalseNoneNoneFalseNoneFalse26241.60
298417998977None1.1.2Open Conduit System Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.25 mm dia 2 mm thick (UNI SR Vol-6, PWD Elec, 2023-24, Pg No. 2, Item No. 1.1.2) m90.7290.72180.0FalseNoneNoneFalseNoneFalse16329.60
298418098977None2.1.1Point wiring using Copper wire with switch.: Supplying and wiring adopting loop system in existing PVC Conduit / casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. (a) Short point upto 3m from tapping point to out let via switch (UNI SR Vol-6, PWD Elec, 2023-24, Pg No. 5, Item No. 2.1.1) Point319.2319.28.0FalseNoneNoneFalseNoneFalse2553.60
298418198977None2.1.2Point wiring using Copper wire with switch.: Supplying and wiring adopting loop system in existing PVC Conduit / casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. (b) Medium point above 3m upto 6m from tapping point to out let via switch (UNI SR Vol-6, PWD Elec, 2023-24, Pg No. 5, Item No. 2.1.2) Point441.28441.2815.0FalseNoneNoneFalseNoneFalse6619.20
298418298977None2.1.3Point wiring using Copper wire with switch.: Supplying and wiring adopting loop system in existing PVC Conduit / casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. (c)Long point above 6m upto 10m from tapping point to out let via switch (UNI SR Vol-6, PWD Elec, 2023-24, Pg No. 5, Item No. 2.1.3) Point638.4638.418.0FalseNoneNoneFalseNoneFalse11491.20
298418398977None2.1.4Point wiring using Copper wire with switch.: Supplying and wiring adopting loop system in existing PVC Conduit / casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. (d)Two outlet in a row, above 3m upto 6m from tapping point to out let via switches. (UNI SR Vol-6, PWD Elec, 2023-24, Pg No. 5, Item No. 2.1.4) Point792.96792.961.0FalseNoneNoneFalseNoneFalse792.960
298418498977None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.The following additional tests are compulsory either to be conducted at works or independent lab with witness by inspecting authority.Additional Tests for FRLS-Applicable Standard Oxygen Index -IS 694-2010, Clause 16.8 Temperature Index -IS 694-2010, Clause 16.13 Smoke Density -IS 694-2010, Clause 16.14Test for Halogen Acid Gas evaluation -IS 694-2010, Clause16.12 (a)1.5 mm2 (UNI SR Vol-6, PWD Elec, 2023-24, Pg No. 5, Item No. 2.3.2) m29.1229.12120.0FalseNoneNoneFalseNoneFalse3494.40
298418598977None2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.The following additional tests are compulsory either to be conducted at works or independent lab with witness by inspecting authority.Additional Tests for FRLS-Applicable Standard Oxygen Index -IS 694-2010, Clause 16.8 Temperature Index -IS 694-2010, Clause 16.13 Smoke Density -IS 694-2010, Clause 16.14Test for Halogen Acid Gas evaluation -IS 694-2010, Clause16.12 (b) 2.5 mm2 (UNI SR Vol-6, PWD Elec, 2023-24, Pg No. 5, Item No. 2.3.3) m47.0447.04240.0FalseNoneNoneFalseNoneFalse11289.60
298418698977None2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694: confirming to latest amendments.The following additional tests are compulsory either to be conducted at works or independent lab with witness by inspecting authority.Additional Tests for FRLS-Applicable Standard Oxygen Index -IS 694-2010, Clause 16.8 Temperature Index -IS 694-2010, Clause 16.13 Smoke Density -IS 694-2010, Clause 16.14Test for Halogen Acid Gas evaluation -IS 694-2010, Clause16.12 (b) 4 mm2 (UNI SR Vol-6, PWD Elec, 2023-24, Pg No. 5, Item No. 2.3.4) m70.5670.56280.0FalseNoneNoneFalseNoneFalse19756.80
298418798977None3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall : 4-5Way (UNI SR Vol-6, PWD Elec SR 2 - 2023-24, Pg No. 8, Item No. 3.4.3) Each198.24198.242.0FalseNoneNoneFalseNoneFalse396.480
298418898977None3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall : 8 Way (UNI SR Vol-6, PWD Elec SR 2 - 2023-24, Pg No. 8, Item No. 3.4.5) Each292.32292.322.0FalseNoneNoneFalseNoneFalse584.640
298418998977None3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall : 10-12 Way (UNI SR Vol-6, PWD Elec SR 2 - 2023-24, Pg No. 8, Item No. 3.4.6) Each357.28357.281.0FalseNoneNoneFalseNoneFalse357.280
298419098977None3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box : 4 Module (UNI SR Vol-6, PWD Elec SR 2 - 2023-24, Pg No. 8, Item No. 3.5.3) Each196.0196.02.0FalseNoneNoneFalseNoneFalse392.00
298419198977None3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box : 8 Module (UNI SR Vol-6, PWD Elec SR 2 - 2023-24, Pg No. 8, Item No. 3.5.5) Each318.0318.02.0FalseNoneNoneFalseNoneFalse636.00
298419298977None3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box : 10-12 Module (UNI SR Vol-6, PWD Elec SR 2 - 2023-24, Pg No. 8, Item No. 3.5.6) Each385.28385.281.0FalseNoneNoneFalseNoneFalse385.280
298419398977None3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (a) 6A One Way Switch (UNI SR Vol-6, PWD Elec SR 2 - 2023-24, Page No. 9,Item No.3.6.1) Each114.42114.4242.0FalseNoneNoneFalseNoneFalse4805.640
298419498977None3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (b) 6A Three Way socket (UNI SR Vol-6, PWD Elec SR 2 - 2023-24, Page No.9, Item No.3.6.3) Each191.52191.528.0FalseNoneNoneFalseNoneFalse1532.160
298419598977None3.6.6Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (c) 600W Dimmer (UNI SR Vol-6, PWD Elec SR 2 - 2023-24, Page No.5/ Item No.3.6.6) Each368.48368.485.0FalseNoneNoneFalseNoneFalse1842.40
298419698977None3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (d) 6A Bell Push ( (UNI SR Vol-6, PWD Elec SR 2 - 2023-24, Page No.5/ Item No.3.6.8 /2022-23 SR) Each198.24198.242.0FalseNoneNoneFalseNoneFalse396.480
298419798977None3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (e) 32A DP Switch (UNI SR Vol-6, PWD Elec SR 2 - 2023-24, Page No.9, Item No.3.6.9) Each365.12365.122.0FalseNoneNoneFalseNoneFalse730.240
298419898977None1.5.1Supplying and fixing PVC/metal conduit Deep junction box 19/20 mm deep Junction box (UNI SR Vol-6, PWD Elec SR 2 - 2023-24 Page No. 2, Item No.1.5.1) Each54.8854.8860.0FalseNoneNoneFalseNoneFalse3292.80
298419998977None6.5.2Supplying wall mounting fan suitable to operate at single- phase 230v AC. supply. 400 mm Sweep (UNI SR Vol-6, PWD Elec SR 2 - 2023-24, Pg No.30, Item No.6.5.2 ) Each3597.443597.442.0FalseNoneNoneFalseNoneFalse7194.880
298420098977None6.4.2Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC) 56" Sweep 5 Star (1400 mm) (UNI SR Vol-6, PWD Elec SR 2 - 2023-24, Pg No.30, Item No.6.4.2 ) Each4204.484204.482.0FalseNoneNoneFalseNoneFalse8408.960
298420198977None13.10Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. ( UNI SR Vol-6, PWD Elec SR 2 - 2023-24 Page No.57, Item No. 13.10) Each191.52191.522.0FalseNoneNoneFalseNoneFalse383.040
298420298977None11.3.2Supplying of .feet -PVC Batten with integrated LED tube . W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 W (UNI SR Vol-6, PWD Elec SR 2 - 2023-24, Page No.43, Item No.11.3.2)Each772.8772.88.0FalseNoneNoneFalseNoneFalse6182.40
298420398977None13.11Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired (UNI SR Vol-6, PWD Elec SR 2 - 2023-24, Page No.57, Item No.13.11) Each352.8352.88.0FalseNoneNoneFalseNoneFalse2822.40
298420498977None13.7.1Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps : On wall/ ceiling / Rafter / Girders (UNI SR Vol-6, PWD Elec SR 2 - 2023-24, Page No. 56 Item No.13.7.1) Each136.64136.642.0FalseNoneNoneFalseNoneFalse273.280
298420598977None3.14.6Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 6A Pendant Holder (UNI SR Vol-6, PWD Elec SR 2 - 2023-24, Page No 10, Item No.3.14.6)"No79.5279.5233.0FalseNoneNoneFalseNoneFalse2624.160
298420698977None5.20.10Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. : 63 A 4 pole (UNI SR Vol-6, PWD Elec SR 2 - 2023-24 Page No 18, Item No.5.20.10) Each6210.46210.42.0FalseNoneNoneFalseNoneFalse12420.80
298420798977None5.18.5Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP (UNI SR Vol-6, PWD Elec SR 2 - 2023-24, Page No 17, Item No.5.18.5) Each1187.21187.22.0FalseNoneNoneFalseNoneFalse2374.40
298420898977None3.13.6Supplying and fixing of metal clad industrial plugs and sockets. 2pole+earth 250V SOCKET 32A (UNI SR Vol-6, PWD Elec SR 2 - 2023-24, Page No 9, Item No.3.13.6)" Each747.08747.082.0FalseNoneNoneFalseNoneFalse1494.160
298420998977None5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.32 A (UNI SR Vol-6, PWD Elec SR 2 - 2023-24, Page No 14, Item No.5.7.2 ) Each269.92269.923.0FalseNoneNoneFalseNoneFalse809.760
298421098977None7.2.2Supplying .litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside Fiber body outside, filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate. 2kW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting : 5 Star With Fibre body 35 L (UNI SR Vol-6, PWD Elec SR 2 - 2023-24, Page No 27 / Item No.7.2.2) Each17404.817404.84.0FalseNoneNoneFalseNoneFalse69619.20
298421198977None13.15.2Erection charges for fixing a . litres capacity wall mounting electric geysers using bolts, flat at one end nut and washers at the other end for through bolts and nuts and washers with 150x450x600mm back plate and wiring complete with 15A 3 pin top : 35 to 50 Litres (UNI SR Vol-6, PWD Elec SR 2 - 2023-24, Page No 57, Item No.13.15.2) Each781.76781.764.0FalseNoneNoneFalseNoneFalse3127.040
298421298977None22.10Making and Fixing pot head for UG Cable only (UNI SR Vol-6, ESCOM SR 2023-24, Page No 52, Item No.22.10) Set318.08318.081.0FalseNoneNoneFalseNoneFalse318.080
298421398977None6.1Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply (UNI SR Vol-6,PWD Elec SR 2 - 2023-24, Page No 30, Item No. 6.1) Each1671.041671.044.0FalseNoneNoneFalseNoneFalse6684.160
298421498977None32.111.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 (Part-1) 50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm) (UNI SR Vol-6, PWD Elec SR 2 - 2023-24, Page No 13, Item No. 32.11) 3.5 core 50 sqmm m200.45200.4575.0FalseNoneNoneFalseNoneFalse15033.750
298421598977None1.6.1Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m (UNI SR Vol-I 2023-24, Page No 6, Item No. 1.6.1) m542.08542.0850.0FalseNoneNoneFalseNoneFalse27104.00
298421698977None21.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff (UNI SR Vol-6, ESCOM 2023-24, Page No 52, Item No. 21.06) m34.8834.8860.0FalseNoneNoneFalseNoneFalse2092.80
298421798977None66.04Supply and laying double walled corrugated (DWC) HDPE Pipe including all necessary connecting Sockets/ Couplings/ Tees/ Bends/ End-caps of same materials in existing trench as per IS 14930 part -II suitable for drawing underground cables. 50mm OD / 42mm ID (UNI SR Vol-6, ESCOM 2023-24, Page No 30, Item No. 536/66.04) m95.2295.2260.0FalseNoneNoneFalseNoneFalse5713.20
298421898977None12.57Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrode should be covered 150 mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. (UNI SR Vol-6, PWD Elec SR 2 - 2023-24, Page No 54, Item No. 12.57) No4766.724766.721.0FalseNoneNoneFalseNoneFalse4766.720
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17101393090000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17101393090000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17101393090000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17101393320000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of kppp portal on or before the last date and time of bid submissionNone
17101393410000NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of kppp portal due to internet connectivity issues and technical glitches at bidders endNone
17101393470000NoneNoneELIGIBILITYTotal value of civl engineering works executed and payments received in the last five years (year-wise)None
17101393530000NoneNoneELIGIBILITYList of existing commitments and ongoing worksNone
17101393650000NoneNoneELIGIBILITYList of works for which tenders already submittedNone
17101393710000NoneNoneELIGIBILITYBanker Details for referenceNone
17101393780000NoneNoneELIGIBILITYConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNone
17101393840000NoneNoneELIGIBILITYReports on the financial standing of the tenderer, such as profit and loss statements and auditors reports for the last five yearsNone
17101393920000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17101393990000NoneNoneELIGIBILITYRegistration with Employees Provident Fund Organisation under EPF and Miscellaneous Provision Act 1952 (Should attach latest copy)None
17101394040000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidder.None
17101394090000NoneNoneELIGIBILITYConditional tenders are not accepted.None
17101394150000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costs. The Cost of the tender form shall not be refundable.None
17101394210000NoneNoneELIGIBILITYThe employer reserves the rights to reject one or all tenders without assigning any reason.None
17101394280000NoneNoneELIGIBILITYThe employer is not responsible for any delay in accessing KPPP portal.None
17101394360000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt orders.None
17101394430000NoneNoneELIGIBILITYTo qualify for award of this contract, each tenderer should give all details and documents as per bid attached to this tenderNone
17101394500000NoneNoneELIGIBILITYMaterials like bitumen, steel, cement etc., required for the work shall be procured by the tenderer themselves and should get tested by the quality control authority before used on the workNone
17101394570000NoneNoneELIGIBILITYAs per Karnataka state Government order LD/300/LET/2006 Blore dated 01.01.07 and Government letter no PW/134/BMS/2007 dated 27.07.07, a sum amounting to 1% of the bill amount will be deducted towards constructions labour welfare fundNone
17101394650000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete manner otherwise it will be rejectedNone
17101394710000NoneNoneELIGIBILITYAll scanned documents to be uploaded shall be in original and the Executive Engineer reserves the right to verify the documents before approvalNone
17101394780000NoneNoneELIGIBILITYOriginal documents/ Certificates enclosed must be produced in the office of Executive Engineer at the time of opening of bid.None
17101394860000NoneNoneELIGIBILITYAll the items in the tender are inclusive of cost of all materials, all leads lifts, loading, unloading, transportation, labour, hire chares of machinery , curing for concrete worksNone
17101394910000NoneNoneELIGIBILITYContractors should follow strictly prevailing rules of labour actNone
17101394980000NoneNoneELIGIBILITYIn case if the death of a contractor, after executing the agreement / commencement of the work, his legal heir, is an eligible registered contractor and is willing, can execute and complete the work, at the accepted tender rates, irrespective of the cost of the workNone
17101395030000NoneNoneELIGIBILITYDepartment will not supply any materialsNone
17101395100000NoneNoneELIGIBILITYThe tenderer should submit proposed methodology and programme of construction backed with equipment and material planning, & deployment duly supported with broad calculation and quality management , plan, proposed to be adopted justifying their capability of execution and completion of the work as per technical specifications and within the stipulated period of completionNone
17101395170000NoneNoneELIGIBILITYThe contractor should maintain the work for the period of 2 years (Two years) after the completion of the work at his own costNone
17101395230000NoneNoneELIGIBILITYThe intending contractors are requested to note that they should abide by the detailed instructions and conditions contained in the Standard Bid document KW 2None
17101395290000NoneNoneELIGIBILITYGST paid separately as per Government order No FWD/65/RDF/2017 Dated:11-10-2018None
17101395350000NoneNoneELIGIBILITYPeriod of contract for which the contractor alone is responsible for delay as determined by the Authority while granting the Extension of Time.None
17101395410000NoneNoneELIGIBILITYWithin 20 days of receipt of the letter of acceptance the successful tenderer shall deliver to the Employer a Additional Security Deposit for unbalance tenders accordance with clause 24.3 of ITT of the Conditions of Contract.None
17101395540000NoneNoneELIGIBILITYThe successful Tenderer shall deliver to the Employer a Security deposit in any of the forms given below for an amount equivalent to 5% of the Contract price plus additional security for unbalanced tenders in accordance with the Conditions of Contract.None
17101395610000NoneNoneELIGIBILITYBidder should quote their rate exclusive of GSTNone
17101564500000NoneNoneELIGIBILITYDefect Liability Period 730 days.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMandating Satisfactorily completion as a prime contractor for at least one similar work to an extent of 50% of the cost of the work such as Similar nature of work of value not less than Rs 16.16 LakhsPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneC )executed in any one year the following minimum quantities of work 1.Pcc/Rcc-29.32 Cum 2. Steel reinforcement-2.20 Tonne 3. Laterite size Stone masonry- 33.80 Cum 4. cement mortar plastering- 478.54 Sqm 5. ceramic glazed floor tiles/ vitrified tiles flooring- 289.30 Sqm 6.providing & fixing fully panneled honne wood shutter doors/ rigid foam prelam panneled door- 28.22 SqmPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneQualification of the Tenderer: 3.1 To qualify for award of this contract, each tenderer in its name should have in the last five years i.e 2018-19 to 2022-23 (a) achieved in at least two financial years an average annual financial turnover (in all classes of civil engineering construction works only) of Rs. 32.31 Lakhs.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneAnnual TurnoverCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneITR Filed Copy (Mentioning PAN)
NoneNoneNoneNone3.4.Tenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated as under Assessed available tender capacity - (AxNx2.5 - B) Where Maximum value of civil engineering works executed in any one year during the last five years (updated to 2023-24 price level) taking into account the completed as well as works in progress N-Number of years prescribed for completion of the works for which Tenders are invited. 08 MonthS. B- Value, at 2023-24 price level, of existing commitments and on-going works to be completed during the next month 08 months (period of completion of the works for which Tenders are invited)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Workdone & Ongoing works Statement as format given in Bid document
NoneNoneNoneNoneList of existing commitments and ongoing worksCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work in hand certificate
NoneNoneNoneNoneList of works for which tenders already submittedCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- On going work list
NoneNoneNoneNoneAll the necessary certificate should be submitted in the prescribed Format as given in Bid Document. Any certificates suporting to the requirements of the qualifications other than prescribed format in Bid document will not be considered and there Tender will be rejected.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Certificates to be furnished in prescribed format
NoneNoneNoneNoneMachineries 1. Concrete Mixer - 01 Nos(01 Own) 2. Screed Vibrator 01 Nos(01 Own) 3.Needle Vibrator 02 Nos(01 Own & 01 Hire/ leased)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Purchase invoice and latest insurance copies
NoneNoneNoneNoneBanker Details for referenceFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Bank Details
NoneNoneNoneNoneliquid assets and /or availability of credit facilities of not less than Rs. 9.70 Lakhs (Credit lines/ letter of credit/ certificates from banks for meeting the fund requirement etcFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneREGISTRATION COPYOthersRegistration
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Company Registration CertificateTrueTechnical Bid
Work Done Certificate Certificate issued by the Competent Authority not below the rank of Executive EngineerTrueTechnical Bid
Works on hand which are to be completed in the next 12 monthsTrueTechnical Bid
LOC/Banker Certificate as per uploaded formatTrueTechnical Bid
itemwise workdone certificate qty required as per mentioned in the bid documentTrueTechnical Bid
GST REGISTRATION CERTIFICATETrueTechnical Bid
ONGOING WORK LISTTrueTechnical Bid
Machineries & Equipments Certificate copy of RC with Ownership, hire deed or purchase invoice with Latest Insurance copiesTrueTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
BuildingsUttara KannadaAnkolaKanaraANKOLABelekeri AnkolaNoneNoneNoneNoneNoneNone
tenderAddressNone
tenderRecallDTONone