createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1710142279360
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee940.00
emd75000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose27-03-2024 16:00:00
tenderQueryClose25-03-2024 16:00:00
technicalBidOpen28-03-2024 17:00:00
publishedDate11-03-2024 17:27:15
publishedByPostIDD_EE_DIV_KWR
publishedByUserKPE12286 - M V PRASAD
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonThippeswamy M R
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08382229672
mobileNumberNone
tenderSupplierListNone
tenderSchedule
createdTs1710142279387
version5
createdDateNone
modifiedDateNone
tenderNumberIDD/2023-24/BD/WORK_INDENT45
titleConstruction of Fish Auction Hall at Belekeri fishery harbour in Ankola Taluka of Uttar Kannada district
descriptionConstruction of Fish Auction Hall at Belekeri fishery harbour in Ankola Taluka of Uttar Kannada district
categoryWORKS
categoryTextWorks
ecv3739679.92
deptNameInfrastructure Development Ports And Inland Water Transport Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location5468
locationNameExecutive engineer Karwar
provisionalAmount5000000.0
groupOverheadTotal0.0
fileNumber03-AEE/PSDK/TECH/KMB/BELKERI/AH/EST/2023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17101422790001NoneNoneBuildingsConstruction of Fish Auction Hall at Belekeri Ankola3739679.92
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
298497599020None19.27.2Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material to the appropriate disposal area as per direction of Engineer-in-charge. Asbestos cement sheet ( UNI SoR 2023-24, Vol 2, Pg No 165, Sl. No 19.27.2) Sqm57.1257.12161.28FalseNoneNoneFalseNoneFalse9212.31360
298497699020None19.16.1Extra for dismantling trusses, rafters, purlins etc. of wood work for every additional height of one metre or part thereof beyond 5 m Of sectional area 40 cm² and above ( UNI SoR 2023-24, Vol 2, Pg No 188, Sl. No 19.16.1) Sqm609.28609.28161.28FalseNoneNoneFalseNoneFalse98264.67840
298497799020None19.10.2Dismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually/ by mechanical means including stacking of serviceable and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. In cement mortar ( UNI SoR 2023-24, Vol 2, Pg No 188, Sl. No 19.10.2) Cum1121.121121.1247.39FalseNoneNoneFalseNoneFalse53129.87680
298497899020None19.2.1Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-charge. ( UNI SoR 2023-24, Vol 2, Pg No 187, Sl. No 19.2.1) Cum1862.561862.5643.1FalseNoneNoneFalseNoneFalse80276.3360
298497999020None1.4Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. ( UNI SoR 2023-24, Vol 1, Sl No 1.4, Pg No 5) Cum271.04271.0465.93FalseNoneNoneFalseNoneFalse17869.66720
298498099020None1.23Providing and filling in foundation with granite / trap broken metal 100mm and down size & with approved sand including hand packing, ramming, watering including cost of all materials and labour with all lead and lift complete as per specifications. ( UNI SoR 2023-24, Vol 1, Pg No 11, Sl. No 1.23) Cum3003.843003.8423.98FalseNoneNoneFalseNoneFalse72032.08320
298498199020None2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) using 40mm nominal size graded crushed coarse aggregates (UNI SoR 2023-24, Vol 1, Sl No 2.1.3, Pg No 15) Cum6707.686707.6817.92FalseNoneNoneFalseNoneFalse120201.62560
298498299020None2.2.5Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ( UNI SoR 2023-24, Vol 1, Sl No 2.2.5, Pg No 15) Cum7861.197861.197.36FalseNoneNoneFalseNoneFalse57858.35840
298498399020None2.3.3Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ( UNI SoR 2023-24, Vol 1, Sl No 2.3.3, Pg No 16) Cum11096.411096.45.39FalseNoneNoneFalseNoneFalse59809.5960
298498499020None2.4.4Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ( UNI SoR 2023-24, Vol 1, Sl No 2.4.4, Pg No 16) Cum12081.6612081.666.9FalseNoneNoneFalseNoneFalse83363.4540
298498599020None2.4.4Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ( UNI SoR 2023-24, Vol 1, Sl No 2.4.4, Pg No 16) Cum12836.7712836.779.36FalseNoneNoneFalseNoneFalse120152.16720
298498699020None2.5.3Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ( UNI SoR 2023-24, Vol 1, Sl No 2.5.3, Pg No 16) Cum11771.7611771.767.65FalseNoneNoneFalseNoneFalse90053.9640
298498799020None2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (The laps and wastages shall not be measured separately) ( UNI SoR 2023-24, Vol 2, Sl No 2.11a, Pg No 18) t100191.84100191.843.85FalseNoneNoneFalseNoneFalse385738.5840
298498899020None5.11Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement 1: 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) ( UNI SoR 2023-24, Vol 2, Sl No 5.1.1, Pg No 9) Cum6284.326284.3230.11FalseNoneNoneFalseNoneFalse189220.87520
298498999020None1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ( UNI SoR 2023-24, Vol 1, Sl No 1.9, Pg No 7) Cum297.92297.9254.96FalseNoneNoneFalseNoneFalse16373.68320
298499099020None5.7Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specifications I.S 3620/1979 having compressive strength not less than 3.5N/sq mm for saturated dry samples - for super structure in CM 1:6. ( UNI SoR 2023-24, Vol 2, Sl No 5.7, Pg No 9) Cum7565.67565.634.61FalseNoneNoneFalseNoneFalse261845.4160
298499199020None7.38Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer- in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (UNI SOR 2023-24, Vol-2, Item No. No 7.38 Page 26 )Sqm636.16636.16139.5FalseNoneNoneFalseNoneFalse88744.320
298499299020None7.39.1Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm) (UNI SOR 2023-24, Vol-2, Item No. No 7.39.1 Page 26 )m505.12505.1215.5FalseNoneNoneFalseNoneFalse7829.360
298499399020None11.16.2Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ( UNI SoR 2023-24, Vol 2, Pg No 82, Sl. No 11.16.2) Kg164.64164.645760.0FalseNoneNoneFalseNoneFalse948326.40
298499499020None12.12Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. ( UNI SoR 2023-24, Vol 2, Pg No 99, Sl. No 12.12) Cum139106.24139106.240.2484FalseNoneNoneFalseNoneFalse34553.9900160
298499599020None12.15Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ) (UNI SoR 2023-24, Vol 2, Pg No 100, Sl. No 12.15) Sqm8337.288337.283.28FalseNoneNoneFalseNoneFalse27346.27840
298499699020None11.34BProviding and fixing M.S. grills of required pattern in frames of win- dows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. ( UNI SoR 2023-24, Vol 2, Pg No 86, Sl. No 11.34B) Kg204.96204.96207.9FalseNoneNoneFalseNoneFalse42611.1840
298499799020None8.3.1Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( UNI SoR 2023-24, Vol 2, Pg No 41, Sl. No 8.3.1) Sqm396.48396.48438.42FalseNoneNoneFalseNoneFalse173824.76160
298499899020None8.27Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ( UNI SoR 2023-24, Vol 2, Pg No 45, Sl. No 8.27) Sqm59.3659.36250.97FalseNoneNoneFalseNoneFalse14897.57920
298499999020None8.28Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ( UNI SoR 2023-24, Vol 2, Pg No 45, Sl. No 8.28) Sqm99.6899.68250.97FalseNoneNoneFalseNoneFalse25016.68960
298500099020None8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (UNI SoR 2023-24, Vol 2, Pg No 46, Sl. No 8.32) Sqm174.72174.72187.45FalseNoneNoneFalseNoneFalse32751.2640
298500199020None8.33.2Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ( UNI SoR 2023-24, Vol 2, Pg No 46, Sl. No 8.33.2) Sqm154.56154.567.94FalseNoneNoneFalseNoneFalse1227.20640
298500299020None8.33.3Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ( UNI SoR 2023-24, Vol 2, Pg No 47, Sl. No 8.33.3) Sqm155.68155.6857.9FalseNoneNoneFalseNoneFalse9013.8720
298500399020None9.1Providing and laying Cement concrete flooring 40 mm thick with 20 mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete. ( UNI SoR 2023-24, Vol 2, Pg No 59, Sl. No 9.1) Sqm505.12505.1293.22FalseNoneNoneFalseNoneFalse47087.28640
298500499020None13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (For 1000 litre capacity) ( UNI SoR 2023-24, Vol 2, Pg No 123, Sl. No 13.34)Ltr10.0810.082000.0FalseNoneNoneFalseNoneFalse20160.00
298500599020None13.31.3Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete. (internal work exposed on wall) - 25mm nominal OD pipes ( UNI SoR 20236-24, Vol 2, Pg No 122, Sl. No 13.31.3) Rmtr356.16356.1645.0FalseNoneNoneFalseNoneFalse16027.20
298500699020None13.31.1Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete. (internal work exposed on wall) - 15mm nominal OD pipes ( UNI SoR 2023-24, Vol 2, Pg No 122, Sl. No 13.31.1) Rmtr203.84203.8460.0FalseNoneNoneFalseNoneFalse12230.40
298500799020None13.2.1Providing and fixing brass bib cock of approved quality : 15 mm nominal bore ( UNI SoR 2023-24, Vol 2, Pg No 117, Sl. No 13.2.1) Nos320.32320.324.0FalseNoneNoneFalseNoneFalse1281.280
298500899020None14.25.1Providing and fixing white vitreous china wash basin including making all connections but including the cost of fittings : Flat back wash basin of size 630x450 mm ( UNI SoR 2023-24, Vol 2, Pg No 135, Sl. No 14.25.1) Each1104.321104.321.0FalseNoneNoneFalseNoneFalse1104.320
298500999020None14.32.2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm ( UNI SoR 2023-24, Vol 2, Pg No 136, Sl. No 14.32.2) Each1140.161140.161.0FalseNoneNoneFalseNoneFalse1140.160
298501099020None9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm ( UNI SoR 2022-23, Vol 2, Pg No 60, Sl. No 9.12.2) Sqm1282.41282.428.91FalseNoneNoneFalseNoneFalse37074.1840
298501199020None11.35.2.2Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. ( UNI SoR 2023-24, Vol 2, Pg No 88, Sl. No 11.35.2.2) Kg639.52639.5251.84FalseNoneNoneFalseNoneFalse33152.71680
298501299020None11.37.2Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m²) including cost of materials, labour, usage charges of machinery complete as per specifications. (UNI SoR 2023-24, Vol 2, Pg No 89, Sl. No 11.37.2) Sqm1311.521311.526.48FalseNoneNoneFalseNoneFalse8498.64960
298501399020None12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)(UNI SOR 2023-24 Vol-5, page No.139 sl.No.12.1)Borewell depth of 50 to 100 Mtrsm519.68519.6820.0FalseNoneNoneFalseNoneFalse10393.60
298501499020None13.8.5Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments)(UNI SOR 2023-24 Vol-5, page No.150 sl.No.13.8.5)2.00 HP/1.5KW 15 STGEach20404.1620404.161.0FalseNoneNoneFalseNoneFalse20404.160
298501599020None13.23.1Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete.(UNI SOR 2023-24 Vol-5, page No.155 sl.No.13.23.1)Upto 3 HP pumpsEach7280.07280.01.0FalseNoneNoneFalseNoneFalse7280.00
298501699020None14.7Supply and laying of LG UT cable having aluminium conductor PVC insulated, sheathed, galvanized steel wire / steel tap armored cable with PVC over sheathing.(UNI SOR 2023-24 Vol-5, page No.176 sl.No.14.7)Rmtr89.689.630.0FalseNoneNoneFalseNoneFalse2688.00
298501799020None990Unplasticised P.V.C.connection pipe with brass union 45 cm long20 mm bore uPVC Pipes 100 mm nominal dia.(UNI SOR 2023-24 Vol-2, page No.A42 sl.No.990)Rmtr530.88530.8830.0FalseNoneNoneFalseNoneFalse15926.40
298501899020None13.31.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 50 mm nominal dia Pipes .(UNI SOR 2023-24 Vol-2, page No.122 sl.No.13.31.6)m874.72874.7230.0FalseNoneNoneFalseNoneFalse26241.60
298501999020None1.1.2Open Conduit System Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.25 mm dia 2 mm thick (UNI SR Vol-6, PWD Elec, 2023-24, Pg No. 2, Item No. 1.1.2)m90.7290.72180.0FalseNoneNoneFalseNoneFalse16329.60
298502099020None2.1.1Point wiring using Copper wire with switch.: Supplying and wiring adopting loop system in existing PVC Conduit / casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. (a) Short point upto 3m from tapping point to out let via switch (UNI SR Vol-6, PWD Elec, 2023-24, Pg No. 5, Item No. 2.1.1)Point319.2319.28.0FalseNoneNoneFalseNoneFalse2553.60
298502199020None2.1.2Point wiring using Copper wire with switch.: Supplying and wiring adopting loop system in existing PVC Conduit / casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. (b) Medium point above 3m upto 6m from tapping point to out let via switch (UNI SR Vol-6, PWD Elec, 2023-24, Pg No. 5, Item No. 2.1.2)Point441.28441.2810.0FalseNoneNoneFalseNoneFalse4412.80
298502299020None2.1.3Point wiring using Copper wire with switch.: Supplying and wiring adopting loop system in existing PVC Conduit / casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. (c)Long point above 6m upto 10m from tapping point to out let via switch (UNI SR Vol-6, PWD Elec, 2023-24, Pg No. 5, Item No. 2.1.3)Point638.4638.418.0FalseNoneNoneFalseNoneFalse11491.20
298502399020None2.1.4Point wiring using Copper wire with switch.: Supplying and wiring adopting loop system in existing PVC Conduit / casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. (d)Two outlet in a row, above 3m upto 6m from tapping point to out let via switches. (UNI SR Vol-6, PWD Elec, 2023-24, Pg No. 5, Item No. 2.1.4)Point792.96792.961.0FalseNoneNoneFalseNoneFalse792.960
298502499020None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.The following additional tests are compulsory either to be conducted at works or independent lab with witness by inspecting authority.Additional Tests for FRLS-Applicable Standard Oxygen Index -IS 694-2010, Clause 16.8 Temperature Index -IS 694-2010, Clause 16.13 Smoke Density -IS 694-2010, Clause 16.14Test for Halogen Acid Gas evaluation -IS 694-2010, Clause16.12 (a)1.5 mm2 (UNI SR Vol-6, PWD Elec, 2023-24, Pg No. 5, Item No. 2.3.2)m29.1229.12180.0FalseNoneNoneFalseNoneFalse5241.60
298502599020None2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.The following additional tests are compulsory either to be conducted at works or independent lab with witness by inspecting authority. Additional Tests for FRLS-Applicable Standard Oxygen Index -IS 694-2010, Clause 16.8 Temperature Index -IS 694-2010, Clause 16.13 Smoke Density -IS 694-2010, Clause 16.14Test for Halogen Acid Gas evaluation -IS 694-2010, Clause16.12 (b) 2.5 mm2 (UNI SR Vol-6, PWD Elec, 2023-24, Pg No. 5, Item No. 2.3.3)m47.0447.04300.0FalseNoneNoneFalseNoneFalse14112.00
298502699020None2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.The following additional tests are compulsory either to be conducted at works or independent lab with witness by inspecting authority. Additional Tests for FRLS-Applicable Standard Oxygen Index -IS 694-2010, Clause 16.8 Temperature Index -IS 694-2010, Clause 16.13 Smoke Density -IS 694-2010, Clause 16.14Test for Halogen Acid Gas evaluation -IS 694-2010, Clause16.12 (b) 4 mm2 (UNI SR Vol-6, PWD Elec, 2023-24, Pg No. 5, Item No. 2.3.4)m70.5670.56360.0FalseNoneNoneFalseNoneFalse25401.60
298502799020None3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall : 8 Way (UNI SR Vol-6, PWD Elec SR 2 - 2023-24, Pg No. 8, Item No. 3.4.5)Each292.32292.322.0FalseNoneNoneFalseNoneFalse584.640
298502899020None3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall : 10-12 Way (UNI SR Vol-6, PWD Elec SR 2 - 2023-24, Pg No. 8, Item No. 3.4.6)Each357.28357.282.0FalseNoneNoneFalseNoneFalse714.560
298502999020None3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box : 8 Module (UNI SR Vol-6, PWD Elec SR 2 - 2023-24, Pg No. 8, Item No. 3.5.5)Each318.08318.084.0FalseNoneNoneFalseNoneFalse1272.320
298503099020None3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box : 10-12 Module (UNI SR Vol-6, PWD Elec SR 2 - 2023-24, Pg No. 8, Item No. 3.5.6)Each385.28385.284.0FalseNoneNoneFalseNoneFalse1541.120
298503199020None3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (a) 6A One Way Switch (UNI SR Vol-6, PWD Elec SR 2 - 2023-24, Page No. 9,Item No.3.6.1)Each114.24114.2440.0FalseNoneNoneFalseNoneFalse4569.60
298503299020None3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (b) 6A Three Way socket (UNI SR Vol-6, PWD Elec SR 2 - 2023-24, Page No.9, Item No.3.6.3)Each191.52191.528.0FalseNoneNoneFalseNoneFalse1532.160
298503399020None3.6.6Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (c) 600W Dimmer (UNI SR Vol-6, PWD Elec SR 2 - 2023-24, Page No.5/ Item No.3.6.6)Each368.48368.482.0FalseNoneNoneFalseNoneFalse736.960
298503499020None3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (d) 6A Bell Push ( (UNI SR Vol-6, PWD Elec SR 2 - 2023-24, Page No.5/ Item No.3.6.8 /2022-23 SR)Each198.24198.241.0FalseNoneNoneFalseNoneFalse198.240
298503599020None3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (e) 32A DP Switch (UNI SR Vol-6, PWD Elec SR 2 - 2023-24, Page No.9, Item No.3.6.9)Each365.12365.121.0FalseNoneNoneFalseNoneFalse365.120
298503699020None1.5.1Supplying and fixing PVC/metal conduit Deep junction box 19/20 mm deep Junction box (UNI SR Vol-6, PWD Elec SR 2 - 2023-24 Page No. 2, Item No.1.5.1)Each54.8854.8836.0FalseNoneNoneFalseNoneFalse1975.680
298503799020None6.4.2Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC) 56" Sweep 5 Star (1400 mm) (UNI SR Vol-6, PWD Elec SR 2 - 2023-24, Pg No.30, Item No.6.4.2 )Each4204.484204.482.0FalseNoneNoneFalseNoneFalse8408.960
298503899020None13.10Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. ( UNI SR Vol-6, PWD Elec SR 2 - 2023-24 Page No.57, Item No. 13.10)Each191.52191.522.0FalseNoneNoneFalseNoneFalse383.040
298503999020None11.3.2Supplying of .feet -PVC Batten with integrated LED tube . W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 W (UNI SR Vol-6, PWD Elec SR 2 - 2023-24, Page No.43, Item No.11.3.2)Each772.8772.812.0FalseNoneNoneFalseNoneFalse9273.60
298504099020None13.11Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired (UNI SR Vol-6, PWD Elec SR 2 - 2023-24, Page No.57, Item No.13.11)Each352.8352.82.0FalseNoneNoneFalseNoneFalse705.60
298504199020None13.7.1Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps : On wall/ ceiling / Rafter / Girders (UNI SR Vol-6, PWD Elec SR 2 - 2023-24, Page No. 56 Item No.13.7.1)Each136.64136.6412.0FalseNoneNoneFalseNoneFalse1639.680
298504299020None3.14.6Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 6A Pendant Holder (UNI SR Vol-6, PWD Elec SR 2 - 2023-24, Page No 10, Item No.3.14.6)Each79.5279.5230.0FalseNoneNoneFalseNoneFalse2385.60
298504399020None5.20.10Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. : 63 A 4 pole (UNI SR Vol-6, PWD Elec SR 2 - 2023-24 Page No 18, Item No.5.20.10)Each6210.46210.42.0FalseNoneNoneFalseNoneFalse12420.80
298504499020None5.18.5Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP (UNI SR Vol-6, PWD Elec SR 2 - 2023-24, Page No 17, Item No.5.18.5)Each1187.21187.24.0FalseNoneNoneFalseNoneFalse4748.80
298504599020None3.13.6Supplying and fixing of metal clad industrial plugs and sockets. 2pole+earth 250V SOCKET 32A (UNI SR Vol-6, PWD Elec SR 2 - 2023-24, Page No 9, Item No.3.13.6)Each747.08747.082.0FalseNoneNoneFalseNoneFalse1494.160
298504699020None5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.32 A (UNI SR Vol-6, PWD Elec SR 2 - 2023-24, Page No 14, Item No.5.7.2 ) Each269.92269.923.0FalseNoneNoneFalseNoneFalse809.760
298504799020None22.10Making and Fixing pot head for UG Cable only (UNI SR Vol-6, ESCOM SR 2023-24, Page No 52, Item No.22.10)Set318.08318.081.0FalseNoneNoneFalseNoneFalse318.080
298504899020None32.111.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 (Part-1) 50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm) (UNI SR Vol-6, PWD Elec SR 2 - 2023-24, Page No 13, Item No. 32.11)m200.45200.4550.0FalseNoneNoneFalseNoneFalse10022.50
298504999020None1.6.1Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m (UNI SR Vol-I 2023-24, Page No 6, Item No. 1.6.1)m542.08542.0850.0FalseNoneNoneFalseNoneFalse27104.00
298505099020None21.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff (UNI SR Vol-6, ESCOM 2023-24, Page No 52, Item No. 21.06)m34.8834.8850.0FalseNoneNoneFalseNoneFalse1744.00
298505199020None66.04Supply and laying double walled corrugated (DWC) HDPE Pipe including all necessary connecting Sockets/ Couplings/ Tees/ Bends/ End-caps of same materials in existing trench as per IS 14930 part -II suitable for drawing underground cables. 50mm OD / 42mm ID (UNI SR Vol-6, ESCOM 2023-24, Page No 30, Item No. 536/66.04)m95.2295.2250.0FalseNoneNoneFalseNoneFalse4761.00
298505299020None12.57Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrode should be covered 150 mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. (UNI SR Vol-6, PWD Elec SR 2 - 2023-24, Page No 54, Item No. 12.57)No4766.724766.722.0FalseNoneNoneFalseNoneFalse9533.440
298505399020None11.9.4Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material,delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with LED Floodlight 150W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Floodlight 150W (UNI SR Vol-6, PWD Elec SR 2 - 2023-24, Page No 46, Item No. 11.9.4)Each13988.813988.812.0FalseNoneNoneFalseNoneFalse167865.60
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17101422920000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17101422920000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17101422920000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17101423110000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of kppp portal on or before the last date and time of bid submissionNone
17101423180000NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of kppp portal due to internet connectivity issues and technical glitches at bidders endNone
17101423250000NoneNoneELIGIBILITYTotal value of civl engineering works executed and payments received in the last five years (year-wise)None
17101423310000NoneNoneELIGIBILITYList of existing commitments and ongoing worksNone
17101423360000NoneNoneELIGIBILITYList of works for which tenders already submittedNone
17101423420000NoneNoneELIGIBILITYBanker Details for referenceNone
17101423490000NoneNoneELIGIBILITYConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNone
17101423570000NoneNoneELIGIBILITYReports on the financial standing of the tenderer, such as profit and loss statements and auditors reports for the last five yearsNone
17101423620000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17101423680000NoneNoneELIGIBILITYRegistration with Employees Provident Fund Organisation under EPF and Miscellaneous Provision Act 1952 (Should attach latest copy)None
17101423740000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidder.None
17101423790000NoneNoneELIGIBILITYConditional tenders are not accepted.None
17101423850000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costs. The Cost of the tender form shall not be refundable.None
17101423920000NoneNoneELIGIBILITYThe employer reserves the rights to reject one or all tenders without assigning any reason.None
17101423970000NoneNoneELIGIBILITYThe employer is not responsible for any delay in accessing KPPP portal.None
17101424030000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt orders.None
17101424100000NoneNoneELIGIBILITYTo qualify for award of this contract, each tenderer should give all details and documents as per bid attached to this tenderNone
17101424150000NoneNoneELIGIBILITYMaterials like bitumen, steel, cement etc., required for the work shall be procured by the tenderer themselves and should get tested by the quality control authority before used on the workNone
17101424220000NoneNoneELIGIBILITYAs per Karnataka state Government order LD/300/LET/2006 Blore dated 01.01.07 and Government letter no PW/134/BMS/2007 dated 27.07.07, a sum amounting to 1% of the bill amount will be deducted towards constructions labour welfare fundNone
17101424290000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete manner otherwise it will be rejectedNone
17101424340000NoneNoneELIGIBILITYAll scanned documents to be uploaded shall be in original and the Executive Engineer reserves the right to verify the documents before approvalNone
17101424400000NoneNoneELIGIBILITYOriginal documents/ Certificates enclosed must be produced in the office of Executive Engineer at the time of opening of bid.None
17101424450000NoneNoneELIGIBILITYAll the items in the tender are inclusive of cost of all materials, all leads lifts, loading, unloading, transportation, labour, hire chares of machinery , curing for concrete worksNone
17101424500000NoneNoneELIGIBILITYContractors should follow strictly prevailing rules of labour actNone
17101424580000NoneNoneELIGIBILITYIn case if the death of a contractor, after executing the agreement / commencement of the work, his legal heir, is an eligible registered contractor and is willing, can execute and complete the work, at the accepted tender rates, irrespective of the cost of the workNone
17101424620000NoneNoneELIGIBILITYDepartment will not supply any materialsNone
17101424680000NoneNoneELIGIBILITYThe tenderer should submit proposed methodology and programme of construction backed with equipment and material planning, & deployment duly supported with broad calculation and quality management , plan, proposed to be adopted justifying their capability of execution and completion of the work as per technical specifications and within the stipulated period of completionNone
17101424750000NoneNoneELIGIBILITYThe contractor should maintain the work for the period of 2 years (Two years) after the completion of the work at his own costNone
17101424810000NoneNoneELIGIBILITYThe intending contractors are requested to note that they should abide by the detailed instructions and conditions contained in the Standard Bid document KW 2None
17101424870000NoneNoneELIGIBILITYGST paid separately as per Government order No FWD/65/RDF/2017 Dated:11-10-2018None
17101424930000NoneNoneELIGIBILITYPeriod of contract for which the contractor alone is responsible for delay as determined by the Authority while granting the Extension of Time.None
17101425010000NoneNoneELIGIBILITYWithin 20 days of receipt of the letter of acceptance the successful tenderer shall deliver to the Employer a Additional Security Deposit for unbalance tenders accordance with clause 24.3 of ITT of the Conditions of Contract.None
17101425070000NoneNoneELIGIBILITYThe successful Tenderer shall deliver to the Employer a Security deposit in any of the forms given below for an amount equivalent to 5% of the Contract price plus additional security for unbalanced tenders in accordance with the Conditions of Contract.None
17101425130000NoneNoneELIGIBILITYBidder should quote their rate exclusive of GSTNone
17101564060000NoneNoneELIGIBILITYDefect Liability Period 730 days.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMandating Satisfactorily completion as a prime contractor for at least one similar work to an extent of 50% of the cost of the work such as Similar nature of work of value not less than Rs. 18.70 lakhsPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneC )executed in any one year the following minimum quantities of work 1. PCC/RCC-43.66 Cum 2.Steel reinforcement-3.08 tonne 3.laterite size stone masonry-27.69 Cum 4.Random rubble stone masonry-24.09 Cum 5. Cement mortar plastering-350.74 Sqm 6. providing and fixing steel work in built up tubular truss-4608.00 kg.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneQualification of the Tenderer: 3.1 To qualify for award of this contract, each tenderer in its name should have in the last five years i.e 2018-19 to 2022-23 (a) achieved in at least two financial years an average annual financial turnover (in all classes of civil engineering construction works only) of Rs. 37.40 Lakhs.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneAnnual TurnoverCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneITR Filed Copy (Mentioning PAN)
NoneNoneNoneNoneList of existing commitments and ongoing worksCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work in hand certificate
NoneNoneNoneNoneList of works for which tenders already submittedCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- On going work list
NoneNoneNoneNoneAll the necessary certificate should be submitted in the prescribed Format as given in Bid Document. Any certificates suporting to the requirements of the qualifications other than prescribed format in Bid document will not be considered and there Tender will be rejected.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Certificates to be furnished in prescribed format
NoneNoneNoneNoneMachineries 1. Concrete Mixer - 01 Nos(01 Own) 2. Crane (5 tonne capacity)-01 Nos(01 hired/ leased) 3.Needle Vibrator 02 Nos(01 Own & 01 Hire/ leased)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Purchase invoice and latest insurance copies
NoneNoneNoneNone3.4.Tenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated as under Assessed available tender capacity - (AxNx2.5 - B) Where Maximum value of civil engineering works executed in any one year during the last five years (updated to 2023-24 price level) taking into account the completed as well as works in progress N-Number of years prescribed for completion of the works for which Tenders are invited. 08 MonthS. B- Value, at 2023-24 price level, of existing commitments and on-going works to be completed during the next month 08 months (period of completion of the works for which Tenders are invited)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Workdone & Ongoing works Statement as format given in Bid document
NoneNoneNoneNoneliquid assets and /or availability of credit facilities of not less than Rs.11.22 Lakhs (Credit lines/ letter of credit/ certificates from banks for meeting the fund requirement etcFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneBanker Details for referenceOthersBANK DETAILS
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- BANK DETAILS
NoneNoneNoneNoneREGISTRATIONOthersRegistration
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Company Registration CertificateTrueTechnical Bid
Work Done Certificate Certificate issued by the Competent Authority not below the rank of Executive EngineerTrueTechnical Bid
Works on hand which are to be completed in the next 12 monthsTrueTechnical Bid
LOC/Banker Certificate as per uploaded formatTrueTechnical Bid
itemwise workdone certificate qty required as per mentioned in the bid documentTrueTechnical Bid
GST REGISTRATION CERTIFICATETrueTechnical Bid
ONGOING WORK LISTTrueTechnical Bid
Machineries & Equipments Certificate copy of RC with Ownership, hire deed or purchase invoice with Latest Insurance copiesTrueTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
BuildingsUttara KannadaAnkolaKanaraANKOLABelekeri AnkolaNoneNoneNoneNoneNoneNone
tenderAddressNone
tenderRecallDTONone