2985488 | 99054 | None | 1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m PWD CSR 2023-24, Vol-I, P. No. 8, I. No. 1.14.1 | Cum | 107.1 | 107.1 | 29.23 | False | None | None | False | None | False | 3130.533 | 0 |
2985489 | 99054 | None | 2.1.2 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications - Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6288.45 | 6288.45 | 2.66 | False | None | None | False | None | False | 16727.277 | 0 |
2985490 | 99054 | None | 5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 15.37 | False | None | None | False | None | False | 103108.8765 | 0 |
2985491 | 99054 | None | 1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 279.3 | 279.3 | 2.76 | False | None | None | False | None | False | 770.868 | 0 |
2985492 | 99054 | None | 1.11 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 454.65 | 454.65 | 2.76 | False | None | None | False | None | False | 1254.834 | 0 |
2985493 | 99054 | None | 2.4.2 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6639.15 | 6639.15 | 2.61 | False | None | None | False | None | False | 17328.1815 | 0 |
2985494 | 99054 | None | A(7) | Formwork shall be added on percentage basis to the finished concrete item rate for formwork shall be considerd as 50% | Cum | 3161.5 | 3161.5 | 2.61 | False | None | None | False | None | False | 8251.515 | 0 |
2985495 | 99054 | None | 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6961.5 | 6961.5 | 1.59 | False | None | None | False | None | False | 11068.785 | 0 |
2985496 | 99054 | None | A(7) | Formwork shall be added on percentage basis to the finished concrete item rate for formwork shall be considerd as 60% | Cum | 3978.0 | 3978.0 | 1.59 | False | None | None | False | None | False | 6325.02 | 0 |
2985497 | 99054 | None | 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6961.5 | 6961.5 | 3.08 | False | None | None | False | None | False | 21441.42 | 0 |
2985498 | 99054 | None | A(7) | Formwork shall be added on percentage basis to the finished concrete item rate for formwork shall be considerd as 60% | Cum | 3978.0 | 3978.0 | 3.08 | False | None | None | False | None | False | 12252.24 | 0 |
2985499 | 99054 | None | 2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/ welding joints, tying with binding wire /soft annealed steel wire and other ancilary operations complete as per drawing and technical specification - For Buildings | t | 93929.85 | 93929.85 | 0.64 | False | None | None | False | None | False | 60115.104 | 0 |
2985500 | 99054 | None | 6.33 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1292.55 | 1292.55 | 38.36 | False | None | None | False | None | False | 49582.218 | 0 |
2985501 | 99054 | None | 6.29 | Half brick masonry with Non Modular fly ash bricks of class designation 5.0, conforming to IS :12894, in super structure above plinth and upto floor I level cement mortar 1 : 3 (1 cement : 3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work | Sqm | 1037.4 | 1037.4 | 9.84 | False | None | None | False | None | False | 10208.016 | 0 |
2985502 | 99054 | None | 8.4.2 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 327.6 | 327.6 | 172.9 | False | None | None | False | None | False | 56642.04 | 0 |
2985503 | 99054 | None | 8.33.1 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life) | Sqm | 165.9 | 165.9 | 276.63 | False | None | None | False | None | False | 45892.917 | 0 |
2985504 | 99054 | None | 9.10 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2 including pointing in white cement mixed with pigment of matching shade complete. | Sqm | 1161.3 | 1161.3 | 2.88 | False | None | None | False | None | False | 3344.544 | 0 |
2985505 | 99054 | None | 10.14 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg/m2, including pointing in white cement mixed with pigment of matching shade complete. | Sqm | 1161.3 | 1161.3 | 19.5 | False | None | None | False | None | False | 22645.35 | 0 |
2985506 | 99054 | None | 11.34B | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc | Kgs | 192.15 | 192.15 | 56.7 | False | None | None | False | None | False | 10894.905 | 0 |
2985507 | 99054 | None | 12.83.2 | Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance 1mm), with wall thickness 2.0 mm ( 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm ( 0.1 mm) wall thickness and 3 nos.stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer- in-charge 42x50 mm PVC Extruded section | m | 250.95 | 250.95 | 20.4 | False | None | None | False | None | False | 5119.38 | 0 |
2985508 | 99054 | None | 12.92 | Providing and fixing of Openable door made out of multi chambered UPVC(Matching to RAL 9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV Thermo Plastic Vulcanized and lead free with gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D 3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm 2.5mm. Maximum possible size 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T and P s shall not be made) | Sqm | 6557.25 | 6557.25 | 5.4 | False | None | None | False | None | False | 35409.15 | 0 |
2985509 | 99054 | None | 12.84 | Providing & fixing of 2track x 2panel sliding windows made out of multi chambered UPVC(Matching to RAL 9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets grey color having isolated drainage and reinforced with Galvanized Iron profile through out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&P s shall not be made) | Sqm | 5274.15 | 5274.15 | 2.16 | False | None | None | False | None | False | 11392.164 | 0 |
2985510 | 99054 | None | 12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL 9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 6004.95 | 6004.95 | 0.54 | False | None | None | False | None | False | 3242.673 | 0 |
2985511 | 99054 | None | 2.16 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications | Sqm | 6555.15 | 6555.15 | 1.88 | False | None | None | False | None | False | 12323.682 | 0 |
2985512 | 99054 | None | 1028 | Water proofing materials | Kg | 46.2 | 46.2 | 50.0 | False | None | None | False | None | False | 2310.0 | 0 |
2985513 | 99054 | None | 13.8.2.2 | Providing and fixing unplasticised PVC connection pipe with brass unions :45 cm length, 20mm NB | No | 115.5 | 115.5 | 4.0 | False | None | None | False | None | False | 462.0 | 0 |
2985514 | 99054 | None | 13.32 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipes | m | 500.85 | 500.85 | 1.0 | False | None | None | False | None | False | 500.85 | 0 |
2985515 | 99054 | None | 13.33.4 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work32 mm nominal dia Pipes | m | 390.6 | 390.6 | 30.0 | False | None | None | False | None | False | 11718.0 | 0 |
2985516 | 99054 | None | 13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. | l | 9.45 | 9.45 | 1000.0 | False | None | None | False | None | False | 9450.0 | 0 |
2985517 | 99054 | None | 13.48 | Providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS 13592 type A, including jointing with seal ring conforming to IS 5382, leaving 10mm gap for thermal expansion, (i) single socketed pipes 100 mm diameter | m | 305.55 | 305.55 | 25.0 | False | None | None | False | None | False | 7638.75 | 0 |
2985518 | 99054 | None | 13.59 | Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete | No | 231.0 | 231.0 | 4.0 | False | None | None | False | None | False | 924.0 | 0 |
2985519 | 99054 | None | 20.44.2 | Providing & fixing White vitreous china water closet squatting pan (Indian type) along with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge Orissa pattern W.C Pan of size 580x440 mm | Each | 3724.35 | 3724.35 | 4.0 | False | None | None | False | None | False | 14897.4 | 0 |
2985520 | 99054 | None | 14.55A | Providing and fixing Bib cock with wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete Economy Class | No | 1172.85 | 1172.85 | 4.0 | False | None | None | False | None | False | 4691.4 | 0 |
2985521 | 99054 | None | 14.7.1 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps | Each | 3236.1 | 3236.1 | 2.0 | False | None | None | False | None | False | 6472.2 | 0 |
2985522 | 99054 | None | 10.14.14 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof includingjointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from theexcavationetc. complete. 6 Kg/m2 200mm(weight of pipe 6.233 kg) (p.no.120. it.no 10.14.14) | m | 1015.35 | 1015.35 | 25.0 | False | None | None | False | None | False | 25383.75 | 0 |
2985523 | 99054 | None | 1.1.1 | Concealed PVC Conduit System Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19 or 20 mm dia 2mm thick | m | 72.45 | 72.45 | 65.0 | False | None | None | False | None | False | 4709.25 | 0 |
2985524 | 99054 | None | 1.5 | PVC/metal conduit Deep Junction Box Supplying and fixing PVC/metal conduit Deep junction box 19/20mm Deep Junction Box | Each | 51.45 | 51.45 | 4.0 | False | None | None | False | None | False | 205.8 | 0 |
2985525 | 99054 | None | 1.6.4 | Flush Mounting Wooden Box Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete. 8" x 6" x 3" (203 x 152 x 76 mm) | Each | 90.3 | 90.3 | 4.0 | False | None | None | False | None | False | 361.2 | 0 |
2985526 | 99054 | None | 1.6.6 | Flush Mounting Wooden Box Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete. 4" x 4" x 3" ( 101 x 101 x 76 mm) | Each | 77.7 | 77.7 | 6.0 | False | None | None | False | None | False | 466.2 | 0 |
2985527 | 99054 | None | 2.3.2 | Wiring for Lightings/Power Circuit Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.1.5 Sqmm | m | 27.3 | 27.3 | 100.0 | False | None | None | False | None | False | 2730.0 | 0 |
2985528 | 99054 | None | 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.5 Sqmm | m | 44.1 | 44.1 | 100.0 | False | None | None | False | None | False | 4410.0 | 0 |
2985529 | 99054 | None | 2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.4 Sqmm | m | 66.15 | 66.15 | 80.0 | False | None | None | False | None | False | 5292.0 | 0 |
2985530 | 99054 | None | 3.6.1 | Modular Switches/Sockets/Regulators etc Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps one way | Each | 107.1 | 107.1 | 4.0 | False | None | None | False | None | False | 428.4 | 0 |
2985531 | 99054 | None | 3.6.2 | Modular Switches/Sockets/Regulators etc Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps two way | Each | 174.3 | 174.3 | 2.0 | False | None | None | False | None | False | 348.6 | 0 |
2985532 | 99054 | None | 3.6.7 | Modular Switches/Sockets/Regulators etc Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 16Amps one way switch | Each | 189.0 | 189.0 | 3.0 | False | None | None | False | None | False | 567.0 | 0 |
2985533 | 99054 | None | 3.6.9 | Modular Switches/Sockets/Regulators etc Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 32Amps DP switch | Each | 342.3 | 342.3 | 1.0 | False | None | None | False | None | False | 342.3 | 0 |
2985534 | 99054 | None | 3.8 | 4mm Thick Plastic Sheets Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screws. | Sq CM | 0.43 | 0.43 | 2000.0 | False | None | None | False | None | False | 860.0 | 0 |
2985535 | 99054 | None | 5.7.2 | Porcelain Fuse Channel Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 32Amps | Each | 253.05 | 253.05 | 4.0 | False | None | None | False | None | False | 1012.2 | 0 |
2985536 | 99054 | None | 5.18 | Miniature Circuit Breakers Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 Amps SP | Each | 435.75 | 435.75 | 4.0 | False | None | None | False | None | False | 1743.0 | 0 |
2985537 | 99054 | None | 5.18.4 | Miniature Circuit Breakers Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 Amps DP | Each | 775.95 | 775.95 | 2.0 | False | None | None | False | None | False | 1551.9 | 0 |
2985538 | 99054 | None | 5.19.3 | MCB Distribution Boards Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.I - Single Door 8 Way SP & N | Each | 1566.6 | 1566.6 | 2.0 | False | None | None | False | None | False | 3133.2 | 0 |
2985539 | 99054 | None | 11.32 | PVC Batten with LED Tubes Supplying of .feet PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70 lumen maintenance with CRI 80. Power Input: 220-240V 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fighting 1 x4 20/22 w | Each | 724.5 | 724.5 | 4.0 | False | None | None | False | None | False | 2898.0 | 0 |
2985540 | 99054 | None | 13.7.1 | Fixing all type of Luminaries Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders | Each | 128.1 | 128.1 | 4.0 | False | None | None | False | None | False | 512.4 | 0 |
2985541 | 99054 | None | 13.19 | Fixing of LED Lights Fixing all types and all capacities of 1'x4' / 2'x2' LED Light fittings indoor on the wall / ceiling / rafters / girders with necessary supporting frame, using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps | Each | 514.5 | 514.5 | 4.0 | False | None | None | False | None | False | 2058.0 | 0 |
2985542 | 99054 | None | 6.1 | Supplyingexhaustfanof1440RPMof300mm(12")sizewithbracketbladescompleteforlightdutysuitabletooperateon230V50Hz, AC Supply | Each | 1566.6 | 1566.6 | 2.0 | False | None | None | False | None | False | 3133.2 | 0 |
2985543 | 99054 | None | 5.35 | Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5to32/63 A three phase 4wire whole current lass-1Accuracy Energy Meter | Cum | 5990.25 | 5990.25 | 1.0 | False | None | None | False | None | False | 5990.25 | 0 |