createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1710129625464
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee2130.00
emd119000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose21-03-2024 15:00:00
tenderQueryClose16-03-2024 15:00:00
technicalBidOpen23-03-2024 15:00:00
publishedDate11-03-2024 14:06:47
publishedByPostDUDC_EE_KLR
publishedByUserKPE11980 - SRINIVAS D
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonAjith Kumar case worker
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9731262015
tenderSupplierListNone
tenderSchedule
createdTs1710129625504
version5
createdDateNone
modifiedDateNone
tenderNumberDMA/2023-24/BD/WORK_INDENT17134
titleConstruction of Primary health center for physically challenged at old slaughter house site in Bamboo bazar road kolar & Construction of Environment friendly toilet for Physically handicap in CMC office premises Kolar
descriptionConstruction of Primary health center for physically challenged at old slaughter house site in Bamboo bazar road kolar & Construction of Environment friendly toilet for Physically handicap in CMC office premises Kolar
categoryWORKS
categoryTextWorks
ecv8500000.01
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2195
locationNameDMA District Urban Development Cell Kolar
provisionalAmount8500000.0
groupOverheadTotal2571716.96
fileNumberCMC/TECH/CR/2023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17101296260001NoneNoneBuildingsConstruction of Primary health center for physically challenged at old slaughter house site in Bamboo bazar road kolar & Construction of Environment friendly toilet for Physically handicap in CMC office premises Kolar5928283.05
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
298233998903Nonecode01Earth work excavation by manual means for drains,canals, waste weir,draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading,caution lights, removal of stumps and other deleterious matter,excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.In all kinds of soils Depth upto 1.5 m.(PWD SR 2023-24 Vol-1 P-05/It no-1.4.1)Cum249.26249.26112.19FalseNoneNoneFalseNoneFalse27964.47940
298234098903Nonecode02Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately).Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates (PWD SR 2023-24 Vol-1 P-15/It no-2.1.3)Cum6168.676168.6715.92FalseNoneNoneFalseNoneFalse98205.22640
298234198903Nonecode03Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :5.1.1 Cement mortar 1:6 (1 cement : 6 coarse sand).(PWD SR 2023-24 Vol-2 P-09/It no-5.1.1)Cum5779.335779.3326.99FalseNoneNoneFalseNoneFalse155984.11670
298234298903Nonecode04Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand). (PWD SR 2023-24Vol-2 P-09/It no-5.2)Cum6816.546816.5418.6FalseNoneNoneFalseNoneFalse126787.6440
298234398903Nonecode05Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates (PWD SR 2023-24 Vol-1 P-15/It noCum6430.296430.299.14FalseNoneNoneFalseNoneFalse58772.85060
298234498903Nonecode06Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.(PWD SR 2023-24 Vol-1 P-15/It no-2.2.3)Cum6526.086526.0812.2FalseNoneNoneFalseNoneFalse79618.1760
298234598903Nonecode07Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).(PWD SR 2023-24 Vol-1 P-15/It no-2.5.2)Cum8457.958457.9546.42FalseNoneNoneFalseNoneFalse392618.0390
298234698903Nonecode08Providing and constructing load bearing wall with Solid Concrete blocksof size 400x200x200mm having block density more than 1800kg/m3and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications (P.17/I-6.32)Cum1349.31349.3346.32FalseNoneNoneFalseNoneFalse467289.5760
298234798903Nonecode09Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per spec(P.17/I-6.33)Cum1267.931267.93134.69FalseNoneNoneFalseNoneFalse170777.49170
298234898903Nonecode10Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(PWD SR 2023-24 P-41/I-8.2.1 vol 2)Sqm379.81379.811021.0FalseNoneNoneFalseNoneFalse387786.010
298234998903Nonecode11Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(PWD SR 2023-24, V-2, P-46/I-8.33.1).Sqm162.74162.74707.53FalseNoneNoneFalseNoneFalse115143.43220
298235098903Nonecode12Supplying, Fitting and Placing TMT Fe 500 & above Reinforcement in Foundation / Substructure /Superstructure complete as per Drawing and Technical Specifications. (PWD SR 2023-24, V-I Page no.18, I.No.2.1.1) a) Buildings At 120 kg/CumTonne92140.7192140.717.85FalseNoneNoneFalseNoneFalse723304.57350
298235198903Nonecode13Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. (PWD SR 2023-24, Vol-2 Page no.86, I.No.11.34A)Sqm173.04173.04409.0False0.00.0FalseNoneFalse70773.360
298235298903Nonecode14Providing & fixing of 2-trackx2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2 (Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm widthx40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mmx53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing beafor fixing of glass shall be of size 9.5mmx21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mmx1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made).(PWD SR 2023-24, V-2 Page no.108, I.No.12.84)Sqm5173.695173.6935.68FalseNoneNoneFalseNoneFalse184597.25920
298235398903Nonecode15Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.(PWD SR 2023-24, Vol 2 pg no 99 It no. 12.11)Cum142216.22142216.220.59FalseNoneNoneFalseNoneFalse83907.56980
298235498903Nonecode16Providing and fixing in position fully panelled Honne wood shutters for doors with , stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures)(PWD SR 2023-24Vol2 pg no 100 It no. 12.17)Sqm7297.557297.5523.93FalseNoneNoneFalseNoneFalse174630.37150
298235598903Nonecode17Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08 and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. (PWD SR 2023-24, V-2 Page no.60, I.No.9.12.2) Size of Tile 600x600 mmSqm1179.351179.35110.18FalseNoneNoneFalseNoneFalse129940.7830
298235698903Nonecode18Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid. (PWD SR 2023-24, V-2 Page no.131, I.No. 14.2.1)Each4983.144983.143.0FalseNoneNoneFalseNoneFalse14949.420
298235798903Nonecode19Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps (PWD SR 2023-24, V-2 Page no.132, I.No. 14.7.1)Each3174.463174.466.0FalseNoneNoneFalseNoneFalse19046.760
298235898903Nonecode20Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings.I.e, fixing the pipe with clamps at 1.00 m spacing, This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Exposed on wall. 20mm dia nominal pipes.(PWD SR 2023-24,Pg No:- 122 I-13.31.2 vol 2)Mtr249.26249.26100.0FalseNoneNoneFalseNoneFalse24926.00
298235998903Nonecode21Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings.I.e, fixing the pipe with clamps at 1.00 m spacing, This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Exposed on wall. 15mm dia nominal pipes.(PWD SR 2023-24, Pg No: 122 I-13.31.2 vol 2)Mtr187.46187.4690.0FalseNoneNoneFalseNoneFalse16871.40
298236098903Nonecode22Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary ydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: For pipes SN4, 125mm dia.(BWSSB 2023-24 It no10.2.3 Pg 113)Mtr396.55396.5590.0FalseNoneNoneFalseNoneFalse35689.50
298236198903Nonecode23Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required :Size 600x450x200 mm (PWD SR 2023-24, Pg No:- 134 I-14.11.1 vol 2)Each5234.465234.464.0FalseNoneNoneFalseNoneFalse20937.840
298236298903Nonecode24Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (PWD SR 2023-24 I-8.5.1,Pg no:50,vol 2)Sqm103.0103.0597.58FalseNoneNoneFalseNoneFalse61550.740
298236398903Nonecode25Providing and placing on terrace(at all Floor levels) popyethylence water storage tank IS:12701 marked, with cover and suitable locjing arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (approved rate)(PWD SR 2023-24, V-02pg No- 13.item 13.34)Ltr9.279.274000.0FalseNoneNoneFalseNoneFalse37080.00
298236498903Nonecode26Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2 mm thick (PWD ELE SR 2023-24 , Pg No:- 02 I-1.2.1)Mtr67.9867.98195.0FalseNoneNoneFalseNoneFalse13256.10
298236598903Nonecode27Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2 mm thick (PWD ELE SR 2023-24 , Pg No:- 02 I-1.2.1) 25 mm dia 2 mm thick (PWD ELE SR 2023-24 I-1.2.2)Mtr80.3480.34185.0FalseNoneNoneFalseNoneFalse14862.90
298236698903Nonecode28Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2 mm thick (PWD ELE SR 2023-24 , Pg No:- 02 I-1.2.1) 32 mm dia 2.5 mm thick (PWD ELE SR 2023-24 I-1.2.3)Mtr106.09106.09175.0FalseNoneNoneFalseNoneFalse18565.750
298236798903Nonecode29Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2 mm thick (PWD ELE SR 2023-24 , Pg No:- 02 I-1.2.1)40 mm dia 2.5 mm thick (PWD ELE SR 2023-24 I-1.2.4)Mtr151.41151.41170.0FalseNoneNoneFalseNoneFalse25739.70
298236898903Nonecode30Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry asrequired with one coat of primer of approved make etc. (PWD ELE SR 2023-24, Pg No:- 02, I-1.4.2) 100 x 75 x 65 mmEach121.54121.5434.0FalseNoneNoneFalseNoneFalse4132.360
298236998903Nonecode31Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry asrequired with one coat of primer of approved make etc. (PWD ELE SR2023-24, Pg No:- 02 I-1.4.4) 180 x 90 x 65 mmEach165.83165.8317.0FalseNoneNoneFalseNoneFalse2819.110
298237098903Nonecode32Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. (PWD ELE SR 2023-24 I-1.7.1) upto 50 mm conduit in brick wallMtr29.8729.87118.0FalseNoneNoneFalseNoneFalse3524.660
298237198903Nonecode33Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. (PWD ELE SR 2023-24 I-1.7.1) upto 50 mm conduit CC floor (PWD ELE SR 2023-24 I-1.7.2)Mtr71.0771.0745.0FalseNoneNoneFalseNoneFalse3198.150
298237298903Nonecode34Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm .... etc. as required. (PWD ELE SR 2023-24 Pg No:- I-1.8.1) 20mmMtr28.8428.84145.0FalseNoneNoneFalseNoneFalse4181.80
298237398903Nonecode35Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm .... etc. as required. (PWD ELE SR 2023-24 Pg No:- I-1.8.1) (PWD ELE SR 2023-24 I-1.8.3) 30mmMtr44.2944.2960.0FalseNoneNoneFalseNoneFalse2657.40
298237498903Nonecode36Supplying And Fixing S Hook made out of 14 mm dia M.S. Rod. (PWD ELE SR 2023-24 I-1.11)Nos53.5653.5640.0FalseNoneNoneFalseNoneFalse2142.40
298237598903Nonecode37Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. (PWD ELE SR 2023-24 I-2.3.3) 2.5 mm2Mtr43.2643.261580.0FalseNoneNoneFalseNoneFalse68350.80
298237698903Nonecode38Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. (PWD ELE SR 2023-24 I-2.3.3) (PWD ELE SR 2023-24 I-2.3.5) 6.0 mm2Mtr94.7694.76680.0FalseNoneNoneFalseNoneFalse64436.80
298237798903Nonecode39Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654. (PWD ELE SR 2023-24 , Pg No :08 I-3.1.2) 6A 3/5 WayEach151.41151.4127.0FalseNoneNoneFalseNoneFalse4088.070
298237898903Nonecode40Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. (PWD ELE SR 2023-24, Pg No:- 08 I-3.3.3 ) 4-5 WayEach141.11141.1127.0FalseNoneNoneFalseNoneFalse3809.970
298237998903Nonecode41Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. (PWD ELE SR 2023-24, I-2.2.1) Short point upto 3m from tapping point to out let via switch boxPoint293.55293.55470.0FalseNoneNoneFalseNoneFalse137968.50
298238098903Nonecode42Medium point above 3m upto 6m from tapping point to out let via switch box (PWD ELE SR 2023-24 I-2.2.2)Point405.82405.82190.0FalseNoneNoneFalseNoneFalse77105.80
298238198903Nonecode43Long point above 6m upto 10m from tapping point to out let via switch box (PWD ELE SR 2023-24 I-2.2.3)Point587.1587.1180.0FalseNoneNoneFalseNoneFalse105678.00
298238298903Nonecode44Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. (PWD ELE SR 2023-24 I-3.3.2) 1-3 WayEach127.72127.7265.0FalseNoneNoneFalseNoneFalse8301.80
298238398903Nonecode45Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. (PWD ELE SR 2023-24 I-3.3.2) (PWD ELE SR 2023-24 I-3.3.3) 4-5 WayEach141.11141.1140.0FalseNoneNoneFalseNoneFalse5644.40
298238498903Nonecode46Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.(PWD ELE SR 2023-24 I-3.5.2) 1 to 3 ModuleEach165.83165.8385.0FalseNoneNoneFalseNoneFalse14095.550
298238598903Nonecode47Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. (PWD ELE SR 2023-24 I-3.5.3) 4 ModuleEach180.25180.2555.0FalseNoneNoneFalseNoneFalse9913.750
298238698903Nonecode48Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. (PWD ELE SR 2023-24 I-3.5.4) 6 ModuleEach241.02241.0245.0FalseNoneNoneFalseNoneFalse10845.90
298238798903Nonecode49Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (PWD ELE SR 2023-24 I-3.6.1) 6A One Way SwitchEach105.06105.06325.0FalseNoneNoneFalseNoneFalse34144.50
298238898903Nonecode50Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (PWD ELE SR 2023-24 I-3.6.1) 6A Two Way Switch (PWD ELE SR 2023-24 I-3.6.2)Each170.98170.98118.0FalseNoneNoneFalseNoneFalse20175.640
298238998903Nonecode51Stepped Fan Regulator Two Module (PWD ELE SR 2023-24 I-3.6.4)Each367.71367.7144.0FalseNoneNoneFalseNoneFalse16179.240
298239098903Nonecode5232A DP Switch (PWD ELE SR 2023-24 I-3.6.9)Each335.78335.78104.0FalseNoneNoneFalseNoneFalse34921.120
298239198903Nonecode53Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu100 lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. (PWD ELE SR 2023-24I-5.14.10) THREE Pole 200 A 35 kAEach14971.0514971.053.0FalseNoneNoneFalseNoneFalse44913.150
298239298903Nonecode54Supplying and fixing of Shunt trip suitable for MCCB.CBCT (PWD ELE SR 2023-24 I-5.15)Each1754.091754.095.0FalseNoneNoneFalseNoneFalse8770.450
298239398903Nonecode55Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCBs as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCBs as outgoings confirming to IS/IEC 60898 - 2. (PWD ELE SR 2023-24 I-5.16.2) 8 WayEach12983.1512983.153.0FalseNoneNoneFalseNoneFalse38949.450
298239498903Nonecode56Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCBs single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. (PWD ELE SR 2023-24 I-5.18.10) II - Double Door 16 Way SP & NEach2995.242995.243.0FalseNoneNoneFalseNoneFalse8985.720
298239598903Nonecode57Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA. (PWD ELE SR 2023-24 I-5.46.3) 63 A SPEach387.28387.289.0FalseNoneNoneFalseNoneFalse3485.520
298239698903Nonecode58Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. (PWD ELE SR 2023-24 I-6.2.2) 15 Sweep (450 mm)Each4579.384579.386.0FalseNoneNoneFalseNoneFalse27476.280
298239798903Nonecode59Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. (PWD ELE SR 2023-24 I-6.3.2) 56 Sweep (1400 mm) Regular modelEach3121.933121.9324.0FalseNoneNoneFalseNoneFalse74926.320
298239898903Nonecode60Supplying wall mounting fan suitable to operate at singlephase 230v AC. supply.(PWD ELE SR 2023-24Each3308.363308.3620.0FalseNoneNoneFalseNoneFalse66167.20
298239998903Nonecode61Supplying.....litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate. 2kW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting. (PWD ELE SR2023-24 I-7.1.3) 25 LEach10549.2610549.262.0FalseNoneNoneFalseNoneFalse21098.520
298240098903Nonecode62Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70 lumen maintenance with CRI Greaterthan 80. Power Input: 220-240V@ 50/60Hz & Power factor Greaterthan0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. (PWD ELE SR 2023-24 I-11.3.2) LED light fitting 1 x 4 - 20/22 WEach710.7710.720.0FalseNoneNoneFalseNoneFalse14214.00
298240198903Nonecode63Supplying of recess mounting non integrated type LED down light...... W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clA, LED of Power/COB with CCT 6500 degree K, CRIGreaterthan 70. efficacy Greaterthan100 lumen per W, 120degree beam spread, lifeGreaterthan 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF Greaterthan 0.95, power loss shouldLessthan 5 of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. (PWD ELE SR 2023-24 I-11.4.2) 10-12WEach1307.071307.0730.0FalseNoneNoneFalseNoneFalse39212.10
298240298903Nonecode64Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V upto 300mA sensitivity on existing wood/panel board. (PWD ELE SR 2023-24 I-5.20.3) 32-40 A 4 poleEach5301.415301.415.0FalseNoneNoneFalseNoneFalse26507.050
298240398903Nonecode65Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. (PWD ELE SR 2023-24 I-5.21)Each9532.659532.653.0FalseNoneNoneFalseNoneFalse28597.950
298240498903Nonecode66Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments 3 HP, size 50x40 Head 30M, Discharge 198 LPM(Vol5 pg no 164 Code SR P440C)Each19380.4819380.482.0FalseNoneNoneFalseNoneFalse38760.960
298240598903Nonecode67Supplying ......TR split Air conditioners suitable for operationon A/C supply single phase 50 Hz 230 V with hermeticallysealed compressor with air cooled condenser, motor capacitorand start run capacitors, relay and over load protector internalunit, with one indoor and one outdoor unit The condenser unit will be placed outside the room on the terrace to avoid noiseincluding standard length of suitable size copper tubingcovered with insulation tube. (High wall chorded/cordless)suitable capacity 3 core sheathed/ PVC copper cable and abattery operated wireless remote unit1.5 Ton capacity(PWD Electrical SR 2023-24, Page no.23, I.No. 6.7)Each49113.4949113.492.0FalseNoneNoneFalseNoneFalse98226.980
298240698903Nonecode68Supplying, installation, testing and commissioning of solar hotwater heater comprising of solar Flat Plate Collector (FPC) ofsize 2120x1040x100mm and stainless steel hot water storagetank with stainless steel heat exchanger absorber made ofcopper sheet and copper tube of following capacity aluminiumbox collector with appropriate capacity electrical back uparrangement excluding inlet and out let pipes. SS Model with100mm thick of 48Kg/M3 density Rock wool insulation with22SWG Aluminium cladding 300 L(PWD Electrical SR 2023-24, Page no.27, I.No. 7.3.3)Each72085.5872085.581.0FalseNoneNoneFalseNoneFalse72085.580
298240798903Nonecode69Supplying, erecting, testing & commissioning of OFF- LINEUPS system suitable for operation on 230V, 50Hz, A/C supply, with all accessories complete and Excluding batteriesand wiring complete 3 kVA OFF LINE UPS(PWD Electrical SR 2023-24 , Page no.2, I.No. 7.3.3)Each30016.2630016.261.0FalseNoneNoneFalseNoneFalse30016.260
298240898903Nonecode70Supplying, installation, testing & commissioning of 12V ..AHbatteries in poly propylene container for D.G. sets. Lowmaintenance batteries, plate type 75 AH capacity(PWD Electrical SR 2023-24, Page no.29, I.No. 9.2)Each17931.2717931.271.0FalseNoneNoneFalseNoneFalse17931.270
298240998903Nonecode71Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion :Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications.(PWD 2023-24 SR Pg no 86 It no 11.35.1.3)Each513.97513.9743.0FalseNoneNoneFalseNoneFalse22100.710
298241098903Nonecode72Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(PWD 2023-24 SR Pg no 86 It no 11.37.1 )Each1017.641017.646.45FalseNoneNoneFalseNoneFalse6563.7780
298241198903Nonecode73Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS:12823 Grade l Type 2, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass stainless steel screws etc. complete as per architectural drawings and directions of engineer-incharge Pre-laminated particle boardwith decorativelamination on one side and balancing lamination on other side including cost of materials, labour, usage charges of machinery complete as per specifications.(PWD 2023-24 SR Pg no 88 It no 11.36.2 vol 2)Each1012.491012.4921.5FalseNoneNoneFalseNoneFalse21768.5350
298241298903Nonecode74Finishing walls with 100 Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge..(PWD 2023-24 SR Pg no 46 It no8.32 vol 2 )Sqm160.68160.68253.27FalseNoneNoneFalseNoneFalse40695.42360
298241398903Nonecode75Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge..(PWD 2023-24 SR Pg no 48 It no8.41 vol 2 )Sqm172.01172.0112.39FalseNoneNoneFalseNoneFalse2131.20390
298241498903Nonecode76Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately).Mix 1:4:8 (M5) Using 40 mm nominal size graded crushed coarse aggregates (PWD SR 2023-24 Vol-1 P-15/It no-2.1.2)Cum5833.925833.922.67FalseNoneNoneFalseNoneFalse15576.56640
298241598903Nonecode77Distempering with oilbound washable distemper of approvedbrand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials ,labour comple teasper specification sand as per directions of Engineer-in-charge..(PWD SR 2023-24P-45/I-8.25 vol 2)Sqm141.11141.11271.84FalseNoneNoneFalseNoneFalse38359.34240
298241698903Nonecode78Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge..(PWD SR 2023-24 P-50/I-8.54.2 vol 2)Sqm113.3113.3271.84FalseNoneNoneFalseNoneFalse30799.4720
298241798903Nonecode79Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete..(PWD SR 2023-24 Vol-2,Pg-13/It no-9.17.2)Size of Tile 600x600 mmSqm1210.251210.2587.97FalseNoneNoneFalseNoneFalse106465.69250
298241898903Nonecode80Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. Thegranite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse ggregates (The cost of steelreinforcement, dowel bars & formwork to be paid separately) (PWD SR 2023-24 P-17/I-2.4.2)Cum7815.237815.2317.05FalseNoneNoneFalseNoneFalse133249.67150
298241998903Nonecode81Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :(PWD SR 2023-24 P-123/I-14.2.2 vol 2) W.C. pan with ISI marked white solid plastic seat and lidSqm2101.22101.26.3FalseNoneNoneFalseNoneFalse13237.560
298242098903Nonecode82Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S.tube of 19x19mm,19 gauge for s tiles and 15x15 mm for top & bottom rails ,covered with heat moulded Pre laminated PVC CC hannel of 5mm thick sheet &30x50mm wide to for m stiles &5mm thick&75mm wide Prelaminated PVC Sheets for top rail,lockrail &bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail,Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S.frame,Sealed to thestiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed tof rames with 3 nos of 75mm Aluminium hinges.do- with one side prelam (PWD SR 2023-24 -106/I-12.55.2 vol 2)Sqm4980.054980.052.0FalseNoneNoneFalseNoneFalse9960.10
298242198903Nonecode83Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings.I.e, fixing the pipe with clamps at 1.00 m spacing, This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.External work. 20mm dia nominal pipes.(PWD SR 2023-24 I-13.32.2 vol 2)Mtr390.37390.3740.0FalseNoneNoneFalseNoneFalse15614.80
298242298903Nonecode84Providing and fixing white vitreous china wash basin including making all connections but including the cost of fittings Flat back wash basin of size 630x450 mm:(PWD SR 2023-24 It no14.25.1 C Pg 128)Each1015.581015.582.0FalseNoneNoneFalseNoneFalse2031.160
298242398903Nonecode85Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Circular shape 450 mm dia(PWD SR 2023-24, V-2 Page no.128, I.No. 14.32.1)Each1120.641120.642.0FalseNoneNoneFalseNoneFalse2241.280
298242498903Nonecode86600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.(PWD SR 2023-24, V-2 Page no.130, I.No. 14.40.2)Each510.88510.882.0FalseNoneNoneFalseNoneFalse1021.760
298242598903Nonecode87Providing and fixing stainless steel ( Grade 304) railing made of Hollowtubes, channels, plates etc., including welding, grinding,buffing,polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge,(for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(PWD SR 2023-24 V-2 Page no.83, I.No. 11.28)Kgs581.95581.95400.0FalseNoneNoneFalseNoneFalse232780.00
298242698903Nonecode88Providing and laying water proofing treatment to the Roof with PU basedsingle component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PUwaterproofing membrane that is highly elastic with elongation greaterthan 400 and tensile strength greater than 2MPa as per ASTM D412.The waterproofing membrane to be applied in 2coats @ 1.6kg per m2to achieve final DFT (dry film thickness) of 1mm including prime coat ofepoxy primer @150 g per m2 and protection with 120gsm Geo-textileover the waterproofing membrane. The finished cost to include surfacepreparation, making coving at Junction, Bore Packing, treatment ofconstruction joints completely as per specification & with a 10 yearswarranty on product & work from certified manufacturers as per thedirection of the Engineer In charge. (PWD SR 2023-24 I-15.1,Pg no:133,vol 2)Sqm841.51841.5183.7FalseNoneNoneFalseNoneFalse70434.3870
298242798903Nonecode89Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (PWD SR 2023-24 I-6.34,Pg no:17,vol 2)Sqm1137.121137.1234.2FalseNoneNoneFalseNoneFalse38889.5040
298242898903Nonecode90Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete (PWD SR 2023-24 I-10.14,Pg no:71, vol2)Sqm1139.181139.1852.5FalseNoneNoneFalseNoneFalse59806.950
298242998903Nonecode91Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.19/20 mm dia 2 mm thick(PWD ELE SR 2023-24 I-1.1.1)Mtr71.0771.0780.0FalseNoneNoneFalseNoneFalse5685.60
298243098903Nonecode92Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.25 mm dia 2 mm thick (PWD ELE SR 2023-24 I-1.1.2)Mtr83.4383.4325.0FalseNoneNoneFalseNoneFalse2085.750
298243198903Nonecode93Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 32 mm dia 2.5 mm thick (PWD ELE SR 2023-24 I-1.1.3)Mtr109.18109.1825.0FalseNoneNoneFalseNoneFalse2729.50
298243298903Nonecode94Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 40 mm dia 2.5 mm thick (PWD ELE SR 2023-24 I-1.1.4)Mtr153.47153.4725.0FalseNoneNoneFalseNoneFalse3836.750
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17101296270000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17101296270000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17101296270000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17101296460000NoneNoneELIGIBILITYAs per tender documentNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneSatisfactory completed, at least one similar type of any type of Building work work of value not less than Rs.29.64 (Excluding GST) Lakhs.as primecontractor.( work done certificate should issued by Employer in charge, not below the rank of an Executive Engineer or equivalent)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneExecuted in one year the following minimum quantities of work executedPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClass III and Above P.W.D registered Civil contractorCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneAssessed available tender capacity (A x N x 2.5 - B)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Assessed available tender capacity
NoneNoneNoneNoneTo qualify for award of this contract, each tenderer in its name should have in the last five years 2018-19 to 2022-23. Achieved in at least two financial years an average annual financial turnover (in all classes of civil engineering construction works only) of Rs.118.56 lakhs.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of not less than Rs.17.78 Lakhs (Credit lines/ letter of credit/ certificates from banks for meeting the fund requirement etc. (usually 30% of amount of contract).Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Company Registration CertificateTrueTechnical Bid
Reserved Category CertificateFalseTechnical Bid
Small Scale Industries CertificateFalseTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone