1709631853000 | 0 | None | None | Other Works | Continuation construction work of Trommel screening machine she in SWM site | 367047.25 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2919930 | 96159 | None | code01 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications (Pg.No:17, I.No:6.32 VOL-2 of PWD SR 2023-24) | Sqm | 1349.3 | 1349.3 | 48.55 | False | None | None | False | None | False | 65508.515 | 0 | 2919931 | 96159 | None | code02 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc tions of Engineer-in-charge.. (I. No 8.3.2 P. No-41 of PWD & IWTD, Vol-2 SR 2023-24) | Sqm | 342.99 | 342.99 | 48.55 | False | None | None | False | None | False | 16652.1645 | 0 | 2919932 | 96159 | None | code03 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge (I. No 8.5.2.1 P. No-42 of PWD & IWTD, Vol-2 SR 2023-24) | Sqm | 359.47 | 359.47 | 48.55 | False | None | None | False | None | False | 17452.2685 | 0 | 2919933 | 96159 | None | code04 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery
complete as per specifications and as per directions of the Engineer-in Charg (I. No 11.25.2 P. No-84 of PWD & IWTD, Vol-2 SR 2023-24) | Kgs | 140.08 | 140.08 | 1175.0 | False | None | None | False | None | False | 164594.0 | 0 | 2919934 | 96159 | None | code05 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and
should be supplied in single length upto 12 m or as desired by Engineer in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required (I. No 7.38 P. No-26 of PWD & IWTD, Vol-2 SR 2023-24) | Sqm | 585.04 | 585.04 | 20.5 | False | None | None | False | None | False | 11993.32 | 0 | 2919935 | 96159 | None | code06 | Providing & fixing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame Flat surface (I. No 7.28.1 P. No-24 of PWD & IWTD, Vol-2 SR 2023-24) | Sqm | 1312.22 | 1312.22 | 17.5 | False | None | None | False | None | False | 22963.85 | 0 | 2919936 | 96159 | None | code07 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. (I. No 9.17.2 P. No-61 of PWD & IWTD, Vol-2 SR 2023-24) | Sqm | 1210.25 | 1210.25 | 17.5 | False | None | None | False | None | False | 21179.375 | 0 | 2919937 | 96159 | None | code08 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials,labour,usage charges of machinery complete as per specifications. (I. No 11.35.2.1 P. No88 of PWD & IWTD, Vol-2 SR 2023-24) | Kgs | 550.02 | 550.02 | 45.0 | False | None | None | False | None | False | 24750.9 | 0 | 2919938 | 96159 | None | code09 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge.(I. No 8.29 P. No.45 of PWD & IWTD, Vol-2 SR 2023-24) | Sqm | 291.49 | 291.49 | 48.55 | False | None | None | False | None | False | 14151.8395 | 0 | 2919939 | 96159 | None | code10 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (I. No 8.32 P. No.46 of PWD & IWTD, Vol-2 SR 2023-24) | Sqm | 160.68 | 160.68 | 48.55 | False | None | None | False | None | False | 7801.014 | 0 |
|