createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1709468680311
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeONE_COVER
evaluationTypeTextOne Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd15275.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose21-03-2024 17:30:00
tenderQueryClose09-03-2024 17:30:00
technicalBidOpenNone
publishedDate04-03-2024 16:32:04
publishedByPostTP_CO_MLPR
publishedByUserKPE13923 - MALLAVVA S PATIL
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonM S TELI
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08332286076
mobileNumber9741493206
tenderSupplierListNone
tenderSchedule
createdTs1709468680347
version4
createdDateNone
modifiedDateNone
tenderNumberDMA/2023-24/WS/WORK_INDENT16097
titleDrilling Borewell and Installing motor and electrical pole Near gandavvagol Farm at 8 No ward 2 Drilling Borewell and installing motor and Construction of cistern near Muttepan temple 3 Constriction of Cistern near Tapakeri house at dupadal village 4 Drilling borewell and installing motor and Construction of Cistern near Ghataprabha TMC office 5 Construction of cistern near Tukkanatti house at Ghataprabha
descriptionDrilling Borewell and Installing motor and electrical pole Near gandavvagol Farm at 8 No ward 2 Drilling Borewell and installing motor and Construction of cistern near Muttepan temple 3 Constriction of Cistern near Tapakeri house at dupadal village 4 Drilling borewell and installing motor and Construction of Cistern near Ghataprabha TMC office 5 Construction of cistern near Tukkanatti house at Ghataprabha
categoryWORKS
categoryTextWorks
ecv610219.86
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location2516
locationNameDMA Town Panchayat Mallapura
provisionalAmount730000.0
groupOverheadTotalNone
fileNumberENG/TMC/GPB/MPC/2021-22/01
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17094686800000NoneNoneWater supply/sewage lines1 Drilling Borewell and Installing motor and electrical pole Near gandavvagol Farm at 8 No ward 2 Drilling Borewell and installing motor and Construction of cistern near Muttepan temple 3 Constriction of Cistern near Tapakeri house at dupadal village 4 Drilling borewell and installing motor and Construction of Cistern near Ghataprabha TMC office 5 Construction of cistern near Tukkanatti house at Ghataprabha610219.86
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
289697694973None001Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. etc. complete (KPWD W.S &S.W Vol-5 2023-24; P.No.140 ; I. No.12.4)Each5552.45552.43.0FalseNoneNoneFalseNoneFalse16657.20
289697794973None002Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: (Above 300m of drilling add 10% for every 50m depth) Borewell depth of 0 to 50 Mtrs (KPWD W.S &S.W Vol-5 2023-24; P.No.139 ; I. No.12.2.1)m324.45324.45150.0FalseNoneNoneFalseNoneFalse48667.50
289697894973None003Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: (Above 300m of drilling add 10% for every 50m depth) Borewell depth of 0 to 50 Mtrs (KPWD W.S &S.W Vol-5 2023-24; P.No.139 ; I. No.12.2.2)m406.35406.35110.0FalseNoneNoneFalseNoneFalse44698.50
289697994973None004Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty.(KPWD W.S &S.W Vol-5 2023-24; P.No.143 ; I. No.12.32)m2029.652029.6518.0FalseNoneNoneFalseNoneFalse36533.70
289698094973None005Providing and laying at site of work MS casing caps as per IS 1239 (part II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge (KPWD W.S &S.W Vol-5 2023-24; P.No.143 ; I. No.12.34)Each172.2172.23.0FalseNoneNoneFalseNoneFalse516.60
289698194973None006roviding Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For 3 HP etc.complete.(3.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00" ) (KPWD W.S &S.W Vol-5 2023-24; P.No.151 ; I. No.13.11.5)Each29518.6529518.653.0FalseNoneNoneFalseNoneFalse88555.950
289698294973None007Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete.Upto 3 HP pumps (KPWD W.S &S.W Vol-5 2023-24; P.No.155; I. No.13.23.1)Each6825.06825.03.0FalseNoneNoneFalseNoneFalse20475.00
289698394973None008SUBMERSIBLE CABLE :Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments.. 1x3x4 Sqm (KPWD W.S &S.W Vol-5 2023-24; P.No.154; I. No.13.22.3 )Each141.75141.75280.0FalseNoneNoneFalseNoneFalse39690.00
289698494973None009Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. HDPE Grade PE80-PN10.0,63mm dia (KPWD W.S &S.W Vol-5 2023-24; P.No.96; I. No.9.3.1 )m264.6264.6255.0FalseNoneNoneFalseNoneFalse67473.00
289698594973None010Supply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 50 mm (KPWD W.S &S.W Vol-5 2023-24;P.No.154; I.No.13.24.1 )Each1312.51312.53.0FalseNoneNoneFalseNoneFalse3937.50
289698694973None011Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work (KPWD W.S &S.W Vol-5 2023-24;P.No.156;I.No.13.32 )Each6825.06825.03.0FalseNoneNoneFalseNoneFalse20475.00
289698794973None012Providing main connection from pole PVC insulated sheathed steel wire cable in new trench as per IS 1554/ 1988 with latest amendments with ISI mark from KPTCL pole to meter board unit. (KPWD W.S &S.W Vol-5 2023-24;P.No.156;I.No.13.36 )m141.75141.7530.0FalseNoneNoneFalseNoneFalse4252.50
289698894973None013KEB Deposite (including Service wire and Connection )Each9000.09000.03.0FalseNoneNoneFalseNoneFalse27000.00
289698994973None014Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. co. for PVC pipes 63mm dia., 6 kg/sqcm & class 3.(KPWD Common DSR 2023-24 Volume 5 (P No: 113 I.No:10.1.4 )m169.05169.0532.0FalseNoneNoneFalseNoneFalse5409.60
289699094973None015Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.In all kinds of soils Depth upto 1.5 m .(KPWD Common DSR 2023-24 Volume 1 (P No: 5 I.No:1.4.1 )Cum254.1254.12.72FalseNoneNoneFalseNoneFalse691.1520
289699194973None016Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates. KPWD Common DSR 2023-24 Volume 1 (P No: 15 I.No:2.1.2 )Cum5947.25947.20.9FalseNoneNoneFalseNoneFalse5352.480
289699294973None017Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)(KPWD Common DSR 2023-24 Volume 2 (P No: 9 I.No:5.3 )Cum6515.256515.256.76FalseNoneNoneFalseNoneFalse44043.090
289699394973None018Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lin ing, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge. (KPWD Common DSR 2023-24 Volume 2 (P No: 44 I.No:8.19.1 )Sqm267.75267.7514.4FalseNoneNoneFalseNoneFalse3855.60
289699494973None019Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery,curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates .KPWD Common DSR 2023-24 Volume 1 (P No: 16 I.No:2.3.1)Cum6639.156639.150.79FalseNoneNoneFalseNoneFalse5244.92850
289699594973None020RCC hume pipe Circular pump house: Providing precast RCC Circular Hume pipe pump house with M.S door and RCC conical roof as per specification and drawings - Internal dia Mtr. 1200 mm & height of 2.5 Mtr. With Wall thickness 65mm etc. complete KPWD Common DSR 2023-24 Volume 5 (P No: 116 I.No:10.6)Each17221.0517221.054.0FalseNoneNoneFalseNoneFalse68884.20
289699694973None021Erection and positioning of RCC Hume pipe pump house/Cistern on size stone masory platform including transportation charges and handling,finishing with all necessary tools ,plants and materials etc.,complete as directed by the Engineer in charge of the work KPWD Common DSR 2023-24 Volume 5 (P No: 116 I.No:10.7)Each1976.11976.14.0FalseNoneNoneFalseNoneFalse7904.40
289699794973None022Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge ( KPWD Common DSR 2023-24 Volume 2 (P No: 45 I.No:8.29)Sqm297.15297.1552.12FalseNoneNoneFalseNoneFalse15487.4580
289699894973None023Providing and fixing brass bib cock of approved quality 20 mm nominal bore ( KPWD Common DSR 2023-24 Volume 2 (P No: 117 I.No:13.2.2)Each320.25320.258.0FalseNoneNoneFalseNoneFalse2562.00
289699994973None024Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) complete Medium Duty GI pipe of 20mm dia ( KPWD Common DSR 2023-24 Volume 5 (P No: 127 I.No:11.2.2)Sqm257.25257.257.6FalseNoneNoneFalseNoneFalse1955.10
289700094973None025Supply and delivery at site wrought middle steel (galvanized) GI bend confirming to IS 1239-II, 1991 with latest amendments if any. For 20 mm dia GI BEND ( KPWD Common DSR 2023-24 Volume 5 (P No: 130 I.No:11.8.2)Each128.1128.18.0FalseNoneNoneFalseNoneFalse1024.80
289700194973None026Supply and delivery at site wrought middle steel (galvanized) GI tee confirming to IS 1239-II, 1991 with latest amendments if any. For 20 mm dia GI TEE ( KPWD Common DSR 2023-24 Volume 5 (P No: 130 I.No:11.9.2)Each112.35112.3510.0FalseNoneNoneFalseNoneFalse1123.50
289700294973None027Earthing: Providing and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia (KPWD W.S &S.W Vol-5 2023-24;P.No.157 ;I.No.13.39 )Job3937.53937.51.0FalseNoneNoneFalseNoneFalse3937.50
289700394973None028PSCC Pole - 8 Mtr Long, 200 Kg WL (including Labour and GST charges )Each4650.04650.02.0FalseNoneNoneFalseNoneFalse9300.00
289700494973None029LT 4 Pin Cross Arm with clamps, bolts, nuts and washers for PSCC Pole - 8 Mtr Long, 200 Kg WL(including Labour and GST charges )Each557.0557.02.0FalseNoneNoneFalseNoneFalse1114.00
289700594973None0301.1 kV Pin Insulator with GI Pin(including Labour and GST charges )Each997.0997.02.0FalseNoneNoneFalseNoneFalse1994.00
289700694973None031No. 8 Strain Insulator(including Labour and GST charges )Each131.0131.02.0FalseNoneNoneFalseNoneFalse262.00
289700794973None032Guy Set Complete with No. 8 Strain Insulator & Concreting materials(including Labour and GST charges )Each1627.01627.02.0FalseNoneNoneFalseNoneFalse3254.00
289700894973None033Weasel ACSR Conductor (including Labour and GST charges )Km39438.039438.00.2FalseNoneNoneFalseNoneFalse7887.60
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17094686810000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17094686810000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17094686810000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17094686810000NoneNoneELIGIBILITYDepartment Registration DetailsNone
17094686810000NoneNoneELIGIBILITYTotal value of civl engineering works executed and payments received in the last five years (year-wise)None
17094686810000NoneNoneELIGIBILITYList of existing commitments and ongoing workNone
17094686810000NoneNoneELIGIBILITYList of works for which tenders already submittedNone
17094686810000NoneNoneELIGIBILITYBanker DetailsNone
preQualCriterionListNone
technicalCriterionListNone
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
License CertificateTrueTechnical Bid
Physical and Quantity work done CertificateTrueTechnical Bid
Nature of Work doneTrueTechnical Bid
Unconditional L O CTrueTechnical Bid
GST CertificateTrueTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
Water supply/sewage linesBelagaviGokakBelgaumGOKAK (ST)GhataprabhaNoneNoneNoneNoneNoneNone
tenderAddressNone
tenderRecallDTONone