createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1709810026697
version12
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee7500.00
emd6024000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose05-04-2024 15:00:00
tenderQueryClose07-03-2024 17:22:00
technicalBidOpen06-04-2024 16:00:00
publishedDate07-03-2024 17:20:19
publishedByPostKPTCL_SE2_TP_BNG
publishedByUserKPE11138 - KRISHNAREDDY G T
bidValidityPeriod180
noOfCalls1
preBidMeetingDate07-03-2024 17:06:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonKrishnareddy GT
splitEmdRequiredYnTrue
emdBankGuarantee5024000.00
emdCash1000000.00
bgValidityPeriod225
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber0802274744
mobileNumber9448365178
tenderSupplierListNone
tenderSchedule
createdTs1709810026698
version20
createdDateNone
modifiedDateNone
tenderNumberKPTCL/2023-24/TL/WORK_INDENT697
titleConversion of existing 220kV Hiriyur-Madhugiri SC Line having Drake Conductor on SC Tower to 220kV DC Line on DC towers with Drake Conductor between 220kV Hiriyur Sub-Station and tapping point of Antharasanahalli-Madhugiri 220kV Line near Thonachagondanagalli (Madhugiri Taluk) for a distance of 69.914km in the existing corridor with Construction of 220kV Terminal Bays along with associated Dismantling work on Total Turnkey Basis
description1Conversion of existing 220kV Hiriyur Madhugiri SC line having Drake Conductor on SC tower to 220kV DC line on DC towers with Drake Conductor between 220kV Hiriyur Sub station and tapping point of Antharasanahalli Madhugiri 220kV line near Thonachagondanagalli (Madhugiri Taluk) for a distance of 69.914km in the existing corridor(2)Construction of 220kV Terminal Bay at 220/66/11kV Hiriyur Sub station in Hiriyur Taluk, Chitradurga District,3.Construction of 220kV Terminal Bay at 220/66/11kV Madhugiri Sub station in Madhugiri Taluk, Tumakuru District,4. Dismantling Portion for the work of Conversion of existing 220kV Hiriyur Madhugiri SC line having Drake Conductor on SC tower to 220kV DC line on DC towers with Drake Conductor between 220kV Hiriyur Sub-station and tapping point of Antharasanahalli Madhugiri 220kV line near Thonacahondanahalli (Madhugiri Taluk) for a distance of 69.914km in the existing corridor,on Total Turnkey Basis including Supply of all matching Materials/Equipments and Erection (including Civil Works) of all Materials/ Equipments,Testing and Commissioning
categoryWORKS
categoryTextWorks
ecv602443885.96
deptNameKarnataka Power Transmission Corporation Limited
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location4550
locationNameKPTCL CEE Corporate Office Tendering and Procurement Bengaluru
provisionalAmount602443889.85
groupOverheadTotalNone
fileNumberKPTCL/CEE/TP/220KV/HIRIYUR-MADHUGIRI/TTK/TLTB-1551
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17098100270000NoneNoneTransmission LineStation supply29814200.96
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
296278197942NoneSS1CIRCUIT BREAKER : SF-6 circuit breakers with rigid, bi-metallic terminal connector suitable for Drake ACSR with spring/semi pneumatic/pneumatic type operating mechanism including mounting arrangements complete as per technical specifications. 220kV, 1250A, 50kA SF6 CB for 220kV line.No1980358.61980358.62.0FalseNoneNoneFalseNoneFalse3960717.20
296278297942NoneSS2ISOLATORS : Isolators including marshalling box,Rigid type terminal connectors with solid core cylindrical post insulators as per technical specifications. 220kV, 1250 A, 40 kA class double break Electrically cum manually operated isolator with solid core insulators 1) Upright mounting type with manually operated Earth Switch LPH 5750 mmSet668210.4668210.42.0FalseNoneNoneFalseNoneFalse1336420.80
296278397942NoneSS32) Upright mounting type without Earth switch LPH 8250 mm.Set566836.6566836.64.0FalseNoneNoneFalseNoneFalse2267346.40
296278497942NoneSS43)Upright mounting type without Earth switch LPH 5750 mm.Set559697.6559697.62.0FalseNoneNoneFalseNoneFalse1119395.20
296278597942NoneSS54)Underhung mounting type without earth switch Note: Terminal connectors for Isolators : Rigid type suitable for Drake ACSR- 24(Hiriyur) +24(Madhugiri)=48 Nos Flexible type suitable for 63mm Al.pipe -6(Hiriyur) +6(Madhugiri) =12NosSet585398.0585398.02.0FalseNoneNoneFalseNoneFalse1170796.00
296278697942NoneSS6CURRENT TRANSFORMER : Current transformer Single phase, oil filled outdoor type with rigid bimetallic terminal connectors suitable for Drake ACSR with marshalling KIOSK complete as per technical specifications. 220kV class, 40 KA, CT of ratio 1200-800-600-300/1-1-1-1A with additional 2 cores of 1200/1A Type-1(1no. of main CTs are used as NCTs) For Metering : Accuracy 0.2s, Burden 10 VA For Differential /Distance protection PS class , Knee Point Voltage = 1200 V at 1200/1 A RCt 12ohms & 400V at 300/1A Rct 3 ohms For Bus bar protection : PS class, Knee Point Voltage = 1200 V at 1200/1 A RCt 12 ohms Note: i) All the CTs in each kV class shall be of one and the same make for inter-changeability & reliability of performance. ii) The make and characteristics of 11kV NCT should be the same as that of the incomer CT of 11kV Switchgear.No419773.2419773.26.0FalseNoneNoneFalseNoneFalse2518639.20
296278797942NoneSS7CAPACITIVE VOLTAGE TRANSFORMER: Single phase, oil filled outdoor type with rigid bimetallic terminal connectors suitable for Drake ACSR as per technical specifications. 220kV class, 4400 PF CVTs of ratio 220kV/sqrt3/110V/sqrt3-110V/sqrt3. Protection Core - 1 & 2 :150 VA, class 3PNo191325.2191325.26.0FalseNoneNoneFalseNoneFalse1147951.20
296278897942NoneSS8SURGE ARRESTOR : (Procelain housing) Metal Oxide Gapless type with rigid bimetallic terminal connectors suitable for Drake ACSR as per technical specifications.. 198kV, 10KA, Discharge Class 3. Note: 198kV Surge arrestors are provided with surge monitors & insulating baseNo69962.269962.26.0FalseNoneNoneFalseNoneFalse419773.20
296278997942NoneSS9A.Control and Relay panel Complete SAS Compatible : 220 kV Line panel Type 2L( as per Annexure RPP1-SAS) Note : 1)The Accuracy class of metering core of CTs and also Electronic trivector meter (with ABT & DLMS features) of control & relay panels shall be 0.2S class and CVTs shall be 0.2 class instead of that specified elsewhere in the respective clauses of Technical specification of bidding documents. 2)All numerical relays shall confirm to IEC 61850 protocal and panel shall be provided with BCU. 3) As there is no SAS in existing Hiriyur station,C&R panel shall be provided with Annunciator & Breaker/Isolator control switch etc. 4)Proposed C&R Panel shall be interfaced with existing Bus-bar protection at Hiriyur Station.No1867562.41867562.41.0FalseNoneNoneFalseNoneFalse1867562.40
296279097942NoneSS10B. Control and Relay panel Complete SCADA Compatible : 220 kV Line panel Type 2L-Duplex type (as per specification) SCADA compatible Note : 1) The Accuracy class of Metering core of CTs and also Electronic trivector meter (with ABT & DLMS features) of control & relay panels shall be 0.2S class and CVTs shall be 0.2 class instead of that specified elsewhere in the respective clauses of Technical specification of bidding documents). 2) The proposed C&R Panel shall be interfaced with existing bus bar protection and SCADA system at Madhugiri station. 3) The C&R panel and associated panels shall match with existing panels in respect of dimension,mimic, etc.,No2227368.02227368.01.0FalseNoneNoneFalseNoneFalse2227368.00
296279197942NoneSS14ii. Earth wire 7/3.15mmMtr103.84103.84200.0FalseNoneNoneFalseNoneFalse20768.00
296279297942NoneSS15RIGID BUS WITH TAPS & CLAMPS : Aluminium Tube conforming to 6340 WP of IS-5082 /1969 (BS 1600-Sch.40) of follwing sizes i. 75 mm size - 220 kV sideMtr1871.481871.4890.0FalseNoneNoneFalseNoneFalse168433.20
296279397942NoneSS16ii.63 mm size for connecting isolator to vertical tap - 220 kV sideMtr1713.361713.36108.0FalseNoneNoneFalseNoneFalse185042.880
296279497942NoneSS17iii.Inverted 'V' taps made of 63 mm Aluminium Tube (BS - 1600) of 2500mm vertical height for vertical portion and cross bus on 220 kV Side with rounded off End.No5370.185370.1812.0FalseNoneNoneFalseNoneFalse64442.160
296279597942NoneSS18Post insulator clamps suitable for 75 mm Aluminium pipe and post insulator Solid core type 1. 220 kV Side a) Rigid typeNo2204.242204.246.0FalseNoneNoneFalseNoneFalse13225.440
296279697942NoneSS19b) Expansion typeNo6279.966279.966.0FalseNoneNoneFalseNoneFalse37679.760
296279797942NoneSS20c) Corona Bell suitable for 75 mm Aluminium Pipe of SizeNo801.22801.226.0FalseNoneNoneFalseNoneFalse4807.320
296279897942NoneSS21d) End cap suitable for 63mm Aluminium pipe on 220kV sideNo728.06728.0612.0FalseNoneNoneFalseNoneFalse8736.720
296279997942NoneSS22INSULATORS: Cylindrical Solid core post Insulator as per IS :5350,Part-II & III & as per technical specification: 1. For 220kV side -2 units/stackStack32336.7232336.7212.0FalseNoneNoneFalseNoneFalse388040.640
296280097942NoneSS232.11kV,120 KN Disc Insulators suitable for Drake ACSR: 220kV side-Single Tension string of 16 units each- 6 strings(16*6=96nos)No946.36946.36192.0FalseNoneNoneFalseNoneFalse181701.120
296280197942NoneSS243.11kV,90 KN,Disc Insulator suitable for Drake ACSR 220kV side- Single Suspension string of 14 units each- 3strings (14*3=42nos) No699.74699.7484.0FalseNoneNoneFalseNoneFalse58778.160
296280297942NoneSS25INSULATOR HARDWARE & CLAMPS as per technical specification: 1. Bolted type Single Tension clamp with hardware suitable for DRAKE ACSR 120KN,20mm -220 kV sideNo2957.082957.0812.0FalseNoneNoneFalseNoneFalse35484.960
296280397942NoneSS262. Bolted type Single Suspension clamp with hardware suitable for Drake ACSR 90KN,16mm -220 kV sideNo1797.141797.146.0FalseNoneNoneFalseNoneFalse10782.840
296280497942NoneSS273.C type Wedge connectors: i. C type Wedge connectors(T-Type) suitable for Drake to Drake ACSR - 220 kV sideNo2719.92719.942.0FalseNoneNoneFalseNoneFalse114235.80
296280597942NoneSS28AC Distribution box (Out door ): AC Distribution box Single front type( outdoor), 6 terminals 750 x1350 x300 mm, one I/C of 100A, MCCB 20KA+ 6 O/G 16A MCB + 1 O/G of 100A HRC Fuse complete as per technical specifications.No51400.851400.82.0FalseNoneNoneFalseNoneFalse102801.60
296280697942NoneSS29LT Power Cable: PVC insulated Alluminium power cable(AC supply for lighting & DFDB/ SFDB etc,.) 1.1kV class 4 X 70 Sq mm LT cable with glands/lugs/ferrulesMtr639.56639.56300.0FalseNoneNoneFalseNoneFalse191868.00
296280797942NoneSS30PVC insulated Copper Control Cable with Lugs / Ferrules. 1.1 KV class, Size of cable: i) 19 Core 2.5 Sq.mm. Copper Control CablesKm619500.0619500.06.0FalseNoneNoneFalseNoneFalse3717000.00
296280897942NoneSS31ii) 10 Core 2.5 Sq.mm. Copper Control CablesKm369340.0369340.03.0FalseNoneNoneFalseNoneFalse1108020.00
296280997942NoneSS32iii) 4 Core 6.0 Sq.mm. Copper Control CablesKm291460.0291460.06.0FalseNoneNoneFalseNoneFalse1748760.00
296281097942NoneSS33iv) 4 Core 2.5 Sq.mm. Copper Control CablesKm167560.0167560.03.0FalseNoneNoneFalseNoneFalse502680.00
296281197942NoneSS34v) 4 Core 4 Sq.mm. Copper Control Cables Note: SS39 Current cable- Copper core with 4.0sqmm cross section multistranded 4 core for CT termination-0.2km for SCADA Integratioon is included.Km208860.0208860.02.2FalseNoneNoneFalseNoneFalse459492.00
296281297942NoneSS35PLCC equipments: 1. PLCC Terminal Single channel (40 W Carrier cabinet )Set858107.8858107.82.0FalseNoneNoneFalseNoneFalse1716215.60
296281397942NoneSS362. Protection coupler-4 command version Note: The existing wave traps in R & B phase of 220kV Hiriyur- Madhugiri SC line. Y phase to be provided to DC line.Set416917.6416917.62.0FalseNoneNoneFalseNoneFalse833835.20
296281497942NoneSS37Materials for New Bay Integration to existing SCADA Panel. i) Multi Functional Transducer (MFT) 0.2S classNo5752.55752.52.0FalseNoneNoneFalseNoneFalse11505.00
296281597942NoneSS38ii) Opto Coupler (220 or 110V DC)No1548.161548.162.0FalseNoneNoneFalseNoneFalse3096.320
296281697942NoneSS40iv) Voltage cables-Copper core with 2.5sqmm cross section multistranded 4 core for PT terminationMtr167.56167.56100.0FalseNoneNoneFalseNoneFalse16756.00
296281797942NoneSS41v) Signal/Communication cables-Armoured Copper core with 0.5sqmm cross section multistranded 10coreMtr168.74168.74100.0FalseNoneNoneFalseNoneFalse16874.00
296281897942NoneSS42vi) Control Cables-Copper core with 1.5sqmm cross section multistrand 10coreMtr182.9182.9100.0FalseNoneNoneFalseNoneFalse18290.00
296281997942NoneSS43vii) RJ-45 cable/CAT Cable for energy meter integration to DCUMtr263.14263.14100.0FalseNoneNoneFalseNoneFalse26314.00
296282097942NoneSS44MISCELLANEOUS ITEMS : 1) Rubber mats 2000 mm x 1000 mm x 12 mm size suitable for 1.1 kV class.No2950.02950.04.0FalseNoneNoneFalseNoneFalse11800.00
296282197942NoneSS452) Fixing of Danger boards/ equipment and earthing name plate.No63.7263.7212.0FalseNoneNoneFalseNoneFalse764.640
17098100270001NoneNoneTransmission LineLine supply501213273.79
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
296282297943NoneLS1Total weight of the Towers (High Tensile Steel) excluding Bolt & Nuts. Note: For detail breakup refer technocommercial sheett175619.4175619.4502.583FalseNoneNoneFalseNoneFalse88263324.91020
296282397943NoneLS2Total weight of the Towers (Mild Steel) excluding Bolt & Nuts Note: (i)Station supply Item No. SS11 - Total Weight of Station structures & Mounting Structures (excluding Bolts & nuts)-20.863t is included.(ii)For detail breakup refer technocommercial sheett159913.6159913.6949.255FalseNoneNoneFalseNoneFalse151798784.3680
296282497943NoneLS3Total weight of the Bolts and Nuts. Note:(i)Station supply Item No. SS12 - Total Weight of Bolts & nuts of Station structures & Mounting Structures is included-0. 918t(ii) For detail breakup refer technocommercial sheett168480.4168480.471.59FalseNoneNoneFalseNoneFalse12061511.8360
296282597943NoneLS6Tower Accessories a) Number Plates (+5 for retained towers)No375.24375.24277.0FalseNoneNoneFalseNoneFalse103941.480
296282697943NoneLS7b) Danger Board (1 No. per tower)No375.24375.24277.0FalseNoneNoneFalseNoneFalse103941.480
296282797943NoneLS8c) Circuit Plates (1 No. per circuit)No375.24375.24554.0FalseNoneNoneFalseNoneFalse207882.960
296282897943NoneLS9d) Phase Plates (Set of 3 Nos.)Set311.52311.52554.0FalseNoneNoneFalseNoneFalse172582.080
296282997943NoneLS10e) Earth Bonds 300mm long (+3 for retained towers)No553.42553.42176.0FalseNoneNoneFalseNoneFalse97401.920
296283097943NoneLS11f) Earth Bonds 450mm long (+2 for retained towers)No634.84634.84101.0FalseNoneNoneFalseNoneFalse64118.840
296283197943NoneLS13Drake ACSR Conductor. Note: Item No SS13 of station supply - Drake ACSR 220kV side-700Mtr is includedKm456660.0456660.0426.476FalseNoneNoneFalseNoneFalse194754530.160
296283297943NoneLS14Insulators strings suitable for DRAKE ACSR CONDUCTOR i. Single Tension insulator strings consisting of any one of the following: a. Insulator string consisting of 1X16nos. of 120kN Disc insulators Or b. Porcelain long rod insulator string equivalent to 1X16nos.of 120kN Disc insulators Or c. Silicon rubber composite insulator equivalent to 1X16nos. of 120kN Disc insulatorsStrings15141.7615141.761332.0FalseNoneNoneFalseNoneFalse20168824.320
296283397943NoneLS15iii. Single Suspension insulator strings consisting of any one of the following: a. Insulator string consisting of 1X14nos. of 90kN Disc insulators Or b. Porcelain long rod insulator string equivalent to 1X14nos. of 90kN Disc insulators Or c. Silicon rubber composite insulator equivalent to 1X14nos. of 90kN Disc insulatorsStrings9796.369796.361242.0FalseNoneNoneFalseNoneFalse12167079.120
296283497943NoneLS16Insulator Hardwares for DRAKE ACSR CONDUCTOR: i. Compression type Single Tension clamp (excluding Disc Insulators) with hardwares & arcing horns suitable for 1X16 units of 120kN Disc insulators to suit DRAKE ACSR conductorSet4434.444434.441116.0FalseNoneNoneFalseNoneFalse4948835.040
296283597943NoneLS17ii. Compression type Double Tension clamp (excluding Disc Insulators) with hardwares & arcing horns suitable for 2X16 units of 120kN Disc insulators to suit DRAKE ACSR conductorSet7898.927898.92108.0FalseNoneNoneFalseNoneFalse853083.360
296283697943NoneLS18iii. Compression type Single Suspension clamp (excluding Disc Insulators) with hardwares & arcing horns suitable for: a. 1X14 units of 90kN Disc insulators to suit DRAKE ACSR conductorSet2769.462769.46870.0FalseNoneNoneFalseNoneFalse2409430.20
296283797943NoneLS19iv. Compression type Double Suspension clamp (excluding Disc Insulators) with hardwares & arcing horns suitable for 2X14 units of 90kN Disc insulators to suit DRAKE ACSR conductorSet5258.085258.08186.0FalseNoneNoneFalseNoneFalse978002.880
296283897943NoneLS20Accessories for Drake ACSR Conductor: a) Mid Span Compression JointsNo1357.01357.0142.0FalseNoneNoneFalseNoneFalse192694.00
296283997943NoneLS21b) Pre formed armour rodsNo3945.923945.921056.0FalseNoneNoneFalseNoneFalse4166891.520
296284097943NoneLS22c) Repair sleevesNo1044.31044.350.0FalseNoneNoneFalseNoneFalse52215.00
296284197943NoneLS23d) Pad clamp compression typeNo1316.881316.881212.0FalseNoneNoneFalseNoneFalse1596058.560
296284297943NoneLS24e) Vibration dampersNo1820.741820.743324.0FalseNoneNoneFalseNoneFalse6052139.760
17098100270000NoneNoneTransmission LineStation Erection1900241.74
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
296284397944NoneSE1CIRCUIT BREAKER : SF-6 circuit breakers with rigid, bi-metallic terminal connector suitable for Drake ACSR with spring/semi pneumatic/pneumatic type operating mechanism including mounting arrangements complete as per technical specifications. 220kV, 1250A, 50kA SF6 CB for 220kV line.No84774.7484774.742.0FalseNoneNoneFalseNoneFalse169549.480
296284497944NoneSE2ISOLATORS : Isolators including marshalling box,Rigid type terminal connectors with solid core cylindrical post insulators as per technical specifications. 220kV, 1250 A, 40 kA class double break Electrically cum manually operated isolator with solid core insulators 1) Upright mounting type with manually operated Earth Switch LPH 5750 mm -2 set 2) Upright mounting type without Earth switch LPH 8250 mm - 4 set 3)Upright mounting type without Earth switch LPH 5750 mm-2 SetSet10152.7210152.728.0FalseNoneNoneFalseNoneFalse81221.760
296284597944NoneSE34)Underhung mounting type without earth switch Note:Terminal connectors for Isolators : Rigid type suitable for Drake ACSR- 24(Hiriyur) +24(Madhugiri) = 48 Nos Flexible type suitable for 63mm Al.pipe -6(Hiriyur) +6(Madhugiri) = 12NosSet14466.814466.82.0FalseNoneNoneFalseNoneFalse28933.60
296284697944NoneSE4CURRENT TRANSFORMER : Current transformer Single phase, oil filled outdoor type with rigid bimetallic terminal connectors suitable for Drake ACSR with marshalling KIOSK complete as per technical specifications. 220kV class, 3.15 KA, CT of ratio 1200-800-600-300/1-1-1-1A with additional 2 cores of 1200/1A Type-1(1no. of main CTs are used as NCTs) For Metering : Accuracy 0.2s, Burden 10 VA For Differential /Distance protection PS class , Knee Point Voltage = 1200 V at 1200/1 A RCt 12ohms & 400V at 300/1A Rct 3 ohms For Bus bar protection : PS class, Knee Point Voltage = 1200 V at 1200/1 A RCt 12 ohms Note: i) All the CTs in each kV class shall be of one and the same make for inter-changeability & reliability of performance. ii) The make and characteristics of 11kV NCT should be the same as that of the incomer CT of 11kV Switchgear.No15134.2915134.296.0FalseNoneNoneFalseNoneFalse90805.740
296284797944NoneSE5CAPACITIVE VOLTAGE TRANSFORMER :Single phase, oil filled outdoor type with rigid bimetallic terminal connectors suitable for Drake ACSR as per technical specifications. 220kV class,CVTs 4400 PF, 220kV/sqrt3/110V/sqrt3-110V/sqrt3. Protection Core - 1 & 2 :150 VA, class 3PNo9397.919397.916.0FalseNoneNoneFalseNoneFalse56387.460
296284897944NoneSE6SURGE ARRESTOR : (Procelain housing) metal oxide gapless type with rigid bimetallic terminal connectors as per technical specifications.. 198kV, 10KA, Discharge Class 3. Note: Surge arrestors are provided with surge monitors & insulating base.No668.67668.676.0FalseNoneNoneFalseNoneFalse4012.020
296284997944NoneSE7A.Control and Relay panel Complete SAS Compatible : 220 kV Line panel Type 2L( as per Annexure RPP1-SAS) Note : 1)The Accuracy class of metering core of CTs and also electronic trivector meter (with ABT & DLMS features) of control & relay panels shall be 0.2S class and CVTs shall be 0.2 class instead of that specified elsewhere in the respective clauses of Technical specification of bidding documents. 2)All numerical relays shall confirm to IEC 61850 protocal and panel shall be provided with BCU. 3) As there is no SAS in existing Hiriyur station,C&R panel shall be provided with Annunciator & Breaker/Isolator control switch etc. 4)Proposed C&R Panel shall be interfaced with existing Bus-bar protection at Hiriyur Station.No93785.2293785.221.0FalseNoneNoneFalseNoneFalse93785.220
296285097944NoneSE8B. Control and Relay panel Complete SCADA Compatible : 220 kV Line panel Type 2L-Duplex type (as per specification) SCADA compatible Note : 1) The Accuracy class of Metering core of CTs and also Electronic trivector meter (with ABT & DLMS features) of control & relay panels shall be 0.2S class and CVTs shall be 0.2 class instead of that specified elsewhere in the respective clauses of Technical specification of bidding documents). 2) The proposed C&R Panel shall be interfaced with existing bus bar protection and SCADA system at Madhugiri station. 3) The C&R panel and associated panels shall match with existing panels in respect of dimension,mimic, etc.,No74239.774239.71.0FalseNoneNoneFalseNoneFalse74239.70
296285197944NoneSE9Total Weight of Station structures & Mounting structures including Bolts & nutst6753.146753.1421.781FalseNoneNoneFalseNoneFalse147090.142340
296285297944NoneSE10Formation of Main/Cross bus with Double Drake ACSR 220kV sideNo23112.6623112.662.0FalseNoneNoneFalseNoneFalse46225.320
296285397944NoneSE11INSULATORS: Cylindrical Solid core post Insulator as per IS :5350,Part-II & III & as per technical specification: For 220kV side -2 units/stackStack667.88667.8812.0FalseNoneNoneFalseNoneFalse8014.560
296285497944NoneSE12AC Distribution box (Out door ): AC Distribution box Single front type( outdoor), 6 terminals 750 x1350 x300 mm, one I/C of 100A, MCCB 20KA+ 6 O/G 16A MCB + 1 O/G of 100A HRC Fuse complete as per technical specifications.No2909.882909.882.0FalseNoneNoneFalseNoneFalse5819.760
296285597944NoneSE13LT Power Cable: 1.1 kV class PVC insulated Alluminium power cable(AC supply for lighting etc,.) 4x 70 Sq mm with glands/lugs/ferrulesMtr36.7436.74300.0FalseNoneNoneFalseNoneFalse11022.00
296285697944NoneSE14Laying of PVC insulated Copper Control Cables 1.1kV Class of sl.no i) to x) of total above. i) 19 Core 2.5 Sq.mm. Copper Control Cables-6 km ii) 10 Core 2.5 Sq.mm. Copper Control Cables-3 km iii) 4 Core 6.0 Sq.mm. Copper Control Cables-6 km iv) 4 Core 2.5 Sq.mm. Copper Control Cables-3 km v) 4 Core 4 Sq.mm. Copper Control Cables-2 km vi) Current cable- Current cable- Copper core with 4.0sqmm cross section multistranded 4 core for CT termination(2 Runs)-0.2 km vii) Voltage cables-Copper core with 2.5sqmm cross section multistranded 4 core for PT termination-0.10 km viii) Signal/Communication cables-Armoured Copper core with 0.5sqmm cross section multistranded 10core- 0.10 km ix) Control Cables-Copper core with 1.5sqmm cross section multistrand 10core-0.10 km x) RJ-45 cable/CAT Cable for energy meter integration to DCU -0.10kmKm17700.017700.020.6FalseNoneNoneFalseNoneFalse364620.00
296285797944NoneSE15PLCC equipments: 1. PLCC Terminal Single channel (40 W Carrier cabinet )Set11165.1611165.162.0FalseNoneNoneFalseNoneFalse22330.320
296285897944NoneSE162. Protection coupler-4 command version Note: The existing wave traps in R & B phase of 220kV Hiriyur- Madhugiri SC line. Y phase to be provided to DC line.Set8865.348865.342.0FalseNoneNoneFalseNoneFalse17730.680
296285997944NoneSE17Earth Mat formation : i. Supplying and laying MS Flat 50 x 8 mm flat welding and applying ACB paint to welded portion without sodium bentoniteas per the drawing/standard specification and consolidationMtr265.5265.5240.0FalseNoneNoneFalseNoneFalse63720.00
296286097944NoneSE18ii. Supplying and Grounding of Equipment and connecting Equipment to the earth mat/ground pit. Each point of earthing with all formation works like bending, twisting, drilling of holes and connecting by welding (inclusive of T&P and consumables) to the earthmat/Groundpit/point of earth connection. G.I.Flat 50x8mmMtr442.5442.5385.0FalseNoneNoneFalseNoneFalse170362.50
296286197944NoneSE19iii. Supplying and Grounding of Equipment and connecting Equipment to the earth mat/ground pit. Each point of earthing with all formation works like bending, twisting, drilling of holes and connecting by welding (inclusive of T&P and consumables) to the earthmat/Groundpit/point of earth connection. G.I.Flat 50x6mmMtr395.3395.3475.0FalseNoneNoneFalseNoneFalse187767.50
296286297944NoneSE20iv) Supplying and Providing 25mm dia M.S.Rod 1.05m long earthmat spikes including heating, bending top 50mm overlap flattening and making spike edge at the ground level and welding the rod with ground mat flat with necessary earth work.No534.54534.549.0FalseNoneNoneFalseNoneFalse4810.860
296286397944NoneSE21v) Grounding of equipment by providing cast iron pipe of 100 mm ID 13 mm thickness, 2.75 metre long with 2 part clamp out of G.I. Flat 50 X 6 mm continuously welded alround the pipe using cast iron welding electrodes as per drawing including the cost of excavation (All materials to be supplied by the contractor)No19213.9419213.9412.0FalseNoneNoneFalseNoneFalse230567.280
296286497944NoneSE22Supplying & providing 450 mm dia 450 mm height 1.5" to 2" thick hume pipe collar (nonpressure type) for earth pits including all lead and lifts etc.,No1768.821768.8212.0FalseNoneNoneFalseNoneFalse21225.840
17098100270000NoneNoneTransmission LineCivil station and line34085967.77
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
296286597945NoneCVL1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 mCum120.36120.366759.73FalseNoneNoneFalseNoneFalse813601.10280
296286697945NoneCVL2Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depthCum428.34428.341892.72FalseNoneNoneFalseNoneFalse810727.68480
296286797945NoneCVL3Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In ordinary/soft rock without blasting Depth exceeding 1.5 m but not exceeding 3 m depthCum501.5501.54191.04FalseNoneNoneFalseNoneFalse2101806.560
296286897945NoneCVL4Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work. In Hard Rock ( requiring blasting) Depth exceeding 1.5 m, but not exceeding 3 mCum735.14735.14675.97FalseNoneNoneFalseNoneFalse496932.58580
296286997945NoneCVL5Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregatesCum7336.067336.06251.36FalseNoneNoneFalseNoneFalse1843992.04160
296287097945NoneCVL6Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, form work, centering & scaffolding and all the other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For foundationsCum7641.217641.211780.2699FalseNoneNoneFalseNoneFalse13603416.1625790
296287197945NoneCVL7Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. All other type of structuresKg93.2393.2395003.65FalseNoneNoneFalseNoneFalse8857190.28950
296287297945NoneCVL8Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum313.88313.8811850.77FalseNoneNoneFalseNoneFalse3719719.68760
296287397945NoneCVL9Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum285.56285.56526.39FalseNoneNoneFalseNoneFalse150315.92840
296287497945NoneCVL10Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work In ordinary/soft rock without blasting Depth exceeding 1.5m, but not exceeding 3 mCum525.1525.174.14FalseNoneNoneFalseNoneFalse38930.9140
296287597945NoneCVL11Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum6683.526683.5224.59FalseNoneNoneFalseNoneFalse164347.75680
296287697945NoneCVL12Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, form work, centering & scaffolding and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For cable ductCum8160.528160.5235.0FalseNoneNoneFalseNoneFalse285618.20
296287797945NoneCVL13Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg133.34133.343699.0FalseNoneNoneFalseNoneFalse493224.660
296287897945NoneCVL14Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 160mm dia., 6 kg/sqcm & class 3 for cable duct E & F typem729.24729.24180.0FalseNoneNoneFalseNoneFalse131263.20
296287997945NoneCVL15Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. And Providing & fixing cast iron cover with frame and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge.Each8750.888750.8810.0FalseNoneNoneFalseNoneFalse87508.80
296288097945NoneCVL16Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. And Providing & fixing cast iron cover with frame and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge.Each7313.647313.6410.0FalseNoneNoneFalseNoneFalse73136.40
296288197945NoneCVL17Jelly Spreading (20-25 mm) : Supplying and providing jelly in the station yard of uniform thickness of 100 mm including the cost of materials, labour charges, required tools and plants etc., complete. Work shall be carried out as per the instructions of Engineer in-charge of works as per the standard procedure.Sqm209.21209.211980.0FalseNoneNoneFalseNoneFalse414235.80
17098100270000NoneNoneTransmission LineLine Erection35430201.7
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
296288297946NoneLE1Check Survey and Towers Spotting Towers : a) Survey using their own equipment including Note: As per UNI SR 2023-24, Volume-VI & Tender DocumentKm3569.53569.569.914FalseNoneNoneFalseNoneFalse249558.0230
296288397946NoneLE2b. Installing insulator strings complete with necessary Hardwares, Installing and stringing of conductor without allowing the conductor to touch the ground and without damaging the conductor including fixing of conductor accessories, etc., (including all the conductors in each phase of all the circuits) - DRAKE ACSR for 220kV LineKm15340.015340.0425.776FalseNoneNoneFalseNoneFalse6531403.840
296288497946NoneLE3Erection of Transmission Line Towers (including tower accessoriesetc., except GI angle with Barbed wire & Grounding materials) Note : 1) The tenderers are required to quote the rates taking in to consideration the charges for sorting of towers parts, loading, unloading, stub seting, fixing of tower accessories,vibration dampers ,aligning, dismantling & transportation of templates from one location to another and tack welding etc., 2) The rates shall be on MT basis.t8881.068881.061501.647FalseNoneNoneFalseNoneFalse13336217.105820
296288597946NoneLE4Grounding of tower including cost of 40mm dia, 2.5mm thick, class 'C' GI pipe of 3mtrs length as per specifications with 50 x 6mm GI flats 3mtrs long, salt, charcoal including excavation charges.Set8655.38655.3272.0FalseNoneNoneFalseNoneFalse2354241.60
296288697946NoneLE5Tower accessories: Supplying and fixing GI angle 45 x 45 X 5mm, 1Mtr length with cleats, bolts nuts as per specification and fixing above 0.5mtr length each at inner and outer surface of tower to facilitate running of barbed wireSet4862.784862.78272.0FalseNoneNoneFalseNoneFalse1322676.160
296288797946NoneLE6Supplying and fixing Barbed wirem89.6889.6842203.22FalseNoneNoneFalseNoneFalse3784784.76960
296288897946NoneLE7Dismantling of existing Transmission Towers with insulators including loading ,unloading and transportation from site to store under shutdown condition. A.Dismantling of existing 220kV Towers : a) 220kV A type towers -185Nos (2.108MT per tower) b) 220kV AP type towers -56Nos (2.89MT per tower)t6753.136753.13551.82FalseNoneNoneFalseNoneFalse3726512.19660
296288997946NoneLE8B. Releasing of existing Drake & Ground wire for 220kV line i. Releasing of existing Drake conductorKm15340.015340.0209.736FalseNoneNoneFalseNoneFalse3217350.240
296289097946NoneLE9ii. Releasing of existing ground wires Note: a)Payment will be made only for the actual weight of towers/conductor length/earth wire length which are dismantled. b) Released/dismantled charges shall include loading/unloading and transportation charges. c) Released/Dismantled materials shall be transported to nearest KPTCL MW storesKm12980.012980.069.912FalseNoneNoneFalseNoneFalse907457.760
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17098100270000NoneNoneELIGIBILITYTenders from Consortium (Limited to maximum of Two(2) constituents including Prime/Lead Bidder) are also acceptableNone
17098100270000NoneNoneELIGIBILITYTenderers shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by any State Government / Government of India / Union Territory.None
17098100270000NoneNoneELIGIBILITYThe Tenderer is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of e-Procurement portal due to internet connectivity issues and technical glitches.None
17098100270000NoneNoneELIGIBILITYThe Tenderer is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of e-Procurement portal due to internet connectivity issues and technical glitches.None
17098100270000NoneNoneELIGIBILITYBank Guarantee towards EMD over and above Rs.10.00Lakh as per Annexure-II of Section-4 shall be sent in original to Chief Engineer Electy., (T&P), KPTCL, Bengaluru so as to reach this office after the last date of submission of bid and on or before the date & time notified for opening of Techno Commercial Bids, in a sealed cover, failing which their bid will not be opened.None
17098100270000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17098100270000NoneNoneELIGIBILITYTenderer shall upload the legible documents only.None
17098100270000NoneNoneELIGIBILITYBidder shall not take any deviations on the clauses listed in the No Deviation Certificate(Annexure-I)None
17098100270000NoneNoneELIGIBILITYAll other terms and conditions as per Tender documentsNone
17098100270000NoneNoneELIGIBILITYPlease note that the Filled in Techno commercial sheet shall be uploaded along with all other QR documents. Offers shall be quoted in the item-wise bid Financial offer, provisioned in the e-procurement portal. In case the Prices are uploaded in/along the Techno commercial Bid, then Bid will be summarily rejected. The Techno-commercial sheets shall be uploaded in KPTCL excel formats onlyNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneDocumentary proof for Clause No. 3.2(b)(i) of ITT such as P.O, LOI/LOA, DWA, Work done Certificates, Performance Certificates issued by the end users not below the rank of Executive/Divisional EngineerPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Others -- Performance certificates, Work Done Certificates, P.O. (Purchase Order) etc
NoneNoneNoneNoneDocumentary proof for Clause No. 3.2(b)(ii) of ITT such as P.O, LOI/LOA, DWA, Work done Certificates, Performance Certificates issued by the end users not below the rank of Executive/Divisional EngineerPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Others -- Performance certificates, Work Done Certificates, P.O. (Purchase Order) etc
NoneNoneNoneNoneThe Tenderer shall upload Bankers Certificate duly signed by authorized person in the prescribed format as at Annexure XVIII of Section-4 and as per the clause no.3.3 (b) of ITT (Liquid Assets and /or availability of credit facilities).Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Others - Relevant Document
NoneNoneNoneNoneAudited financial statements including Balance sheets, Profit and Loss statements, Turnover Certificate, Auditors Reports of the last five years preceding the date of bid submission of the Bidder & Consortium member(In case of Consortium)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Balance sheets, Profit and Loss statements, Turnover Certificate, Auditors Reports
NoneNoneNoneNoneDocumentary proof for Clause No: 3.6 of ITT: Assessed available tender capacity such as, Statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent or verified and certified by Chartered Accountant/Cost Auditor as sought in Note of the said clause in the prescribed format as in clause No: 1.5 of Qualification InformationFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant documents
NoneNoneNoneNoneThe Tenderer shall upload the scanned copy of the Bank Guarantee towards EMD as per Clause No.13.1 of ITTOthersRelevant documents
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant documents
NoneNoneNoneNoneself-declaration as sought in Clause No. 3.6 Note (ii) of ITT by the Lead Bidder & Consortium partner(in case of Consortium) stating that the information with regard to assessed available tender capacity (Works on Hand) furnished are correctOthersRelevant documents
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant documents
NoneNoneNoneNoneSelf-declarations of Lead Bidder & Consortium partner (In case of Consortium) in respect of Litigation, dis-qualification due to non-performance, Risk & cost clause and Restriction on border sharing as specified in Annexure- XVII& Annexure-XVIII as per Clause No.2.4of ITTOthersRelevant documents
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant documents
NoneNoneNoneNoneConsortium Agreement(if applicable).OthersRelevant documents
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant documents
NoneNoneNoneNonePower of Attorney in favour of all the persons signing the documents, Power of Attorney for Consortium, combined power of attorney signed by the signatories of all the members of consortium as an evidence of authorization for nominating leader (Prime Bidder) of consortiumOthersRelevant documents
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant documents
NoneNoneNoneNoneValid Super Grade Electrical Contractors License of both Lead Bidder & Consortium partner (in case of Consortium) issued by the Govt. of KarnatakaOthersRelevant documents
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant documents
NoneNoneNoneNoneCertificate of Incorporation of the Individual/Consortium or any relevant document in respect of Partnership/Proprietorship firms as per the tender documentOthersRelevant documents
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant documents
NoneNoneNoneNoneThe bidder and Consortium Partner (In case of Consortium) should have valid GST registration with GSTIN number, PAN Card and ISO CertificatesOthersRelevant documents
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant documents
NoneNoneNoneNoneNo Deviation Certificate.OthersRelevant documents
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant documents
NoneNoneNoneNoneLetter of Undertaking as in AnnexureOthersRelevant documents
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant documents
NoneNoneNoneNoneThe Qualification and experience of key Personnel proposed for carrying out the WorkOthersRelevant documents
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant documents
NoneNoneNoneNoneDescription of the Tools & Plant available with them for execution of the WorkOthersRelevant documents
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant documents
NoneNoneNoneNoneundertaking to source the supply of equipment/material from KPTCL approved Vendors only as per the QR for Vendor registration, available in the KPTCL website i.e., https://kptcl.karnataka.gov.in, Link Tender and Procurement - application for Vendor registration etcOthersUndertakings
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Undertakings
NoneNoneNoneNoneundertaking to source the supply of equipment/material from Vendors who meet the eligibility clauses regarding restriction on procurement from a country which shares land border with India as specified in Annexure- XVIIOthersUndertakings
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Undertakings
NoneNoneNoneNoneDetails of Works on hand and Ongoing contractual commitmentsOthersRelevant documents
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant documents
NoneNoneNoneNoneUpload all relevant documents as per Section-3 Qualifying information, NIT, Terms & conditions as stipulated in the Tender DocumentOthersRelevant documents
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant documents
NoneNoneNoneNoneCopies of original documents defining the Constitution or Legal Status, place of Registration and Principal place of Business of the Bidder (Lead Bidder & Consortium Partner) , written Power of Attorney to the Signatory of the Bid to commit the Bidder (Lead Bidder & Consortium Partner) to the Contract along with the resolution passed in this regard by the Board of Directors all the Partners of the FirmOthersRelevant documents
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant documents
NoneNoneNoneNoneTenderer shall upload Duly filled in Techno Commercial Sheets.OthersRelevant documents
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant documents
NoneNoneNoneNoneAny other relevant documentsOthersRelevant documents
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant documents
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Techno commercial sheetTrueTechnical Bid
Company Registration CertificateTrueTechnical Bid
Other documents if anyTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1709811296000
version0
createdDateNone
modifiedDateNone
blockNumberKaveriBhavan
streetNone
cityBengaluru
stateKarnataka
pin560009
tenderRecallDTONone