createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1710488954580
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee3020.00
emd200000.00
bidValueTypeLUMPSUM
bidValueTypeTextLumpsum
tenderReceiptClose08-04-2024 17:30:00
tenderQueryClose30-03-2024 16:41:19
technicalBidOpen10-04-2024 11:42:17
publishedDate15-03-2024 15:50:47
publishedByPostKPTCL_EE_WMC_CIR_MUN
publishedByUserKPE12719 - MOUNESH S PATTAR
bidValidityPeriod180
noOfCalls1
preBidMeetingDate15-03-2024 17:00:24
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonASST EXECUTIVE ENGINEER ELE
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9448998051
tenderSupplierListNone
tenderSchedule
createdTs1710488954612
version4
createdDateNone
modifiedDateNone
tenderNumberKPTCL/2023-24/TL/WORK_INDENT840
titleConstruction of 1 No. of 110KV Terminal Bay at existing 110/11KV Sub-station Ganadal for the proposed 110KV LILO Line by utilizing 110KV DC towers from the tapping point of existing 110KV Kushtagi-Kanakagiri Line for a distance of 1.62Kms in Yelburga Taluk of Koppal District on Total Turn Key Basis.
descriptionConstruction of 1 No. of 110KV Terminal Bay at existing 110/11KV Sub-station Ganadal for the proposed 110KV LILO Line by utilizing 110KV DC towers from the tapping point of existing 110KV Kushtagi-Kanakagiri Line for a distance of 1.62Kms in Yelburga Taluk of Koppal District on Total Turn Key Basis.
categoryWORKS
categoryTextWorks
ecv12047630.98
deptNameKarnataka Power Transmission Corporation Limited
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location4622
locationNameKPTCL SEE Transmission Works and Mantainance Circle Munirabad
provisionalAmount12048000.0
groupOverheadTotal2323957.88
fileNumberSEE/WMC/MRB/AEE-1/2023-24/193/13-03-2024
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17104889550000NoneNoneTransmission LineConstruction of 1 No. of 110KV Terminal Bay at existing 110/11KV Sub-station Ganadal for the proposed 110KV LILO Line by utilizing 110KV DC towers from the tapping point of existing 110KV Kushtagi-Kanakagiri Line for a distance of 1.62Kms in Yelburga Taluk of Koppal District on Total Turn Key Basis.9723673.1
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3086464106012NoneMS1Tower accessories-Circuit plateNo318.0318.07.0FalseNoneNoneFalseNoneFalse2226.00
3086465106012NoneMS2Tower accessories-Phase plate (Set of 3 No.)Set528.0528.07.0FalseNoneNoneFalseNoneFalse3696.00
3086466106012NoneMS3ACSR Lynx Conductor Plain TerrianKm946560.0946560.04.933FalseNoneNoneFalseNoneFalse4669380.480
3086467106012NoneMS4Earth wire -7-3.15mm Ground wire Plain TerrianKm2640.02640.00.03FalseNoneNoneFalseNoneFalse79.20
3086468106012NoneMS5Single Tension string of 8 units 90KN each along with hardware for Lynx ACSR and arcing horn of Stack setsNos6385.06385.015.0FalseNoneNoneFalseNoneFalse95775.00
3086469106012NoneMS6Double Tension string of 8 units 90KN each along with hard ware for Lynx ACSR and arcing horn of Stack setsNos14159.014159.03.0FalseNoneNoneFalseNoneFalse42477.00
3086470106012NoneMS7Single Suspension string of 7 units 90KN each.along with hardware for Lynx ACSR and arcing horn of Stack setsNos6144.06144.03.0FalseNoneNoneFalseNoneFalse18432.00
3086471106012NoneMS8Double Suspension String of 7 Units 90KN each along with hardware for Lynx ACSR and arcing horn of Stack setsNos12104.012104.09.0FalseNoneNoneFalseNoneFalse108936.00
3086472106012NoneMS9M S C Joints suitable for Lynx ACSRNos668.0668.02.0FalseNoneNoneFalseNoneFalse1336.00
3086473106012NoneMS10Pre formed armour rods suitable for Lynx ACSRNos1263.01263.012.0FalseNoneNoneFalseNoneFalse15156.00
3086474106012NoneMS11Repair sleeves suitable for Lynx ACSRNos592.0592.02.0FalseNoneNoneFalseNoneFalse1184.00
3086475106012NoneMS12P G Clamps suitable for LYNX ACSRNos776.0776.018.0FalseNoneNoneFalseNoneFalse13968.00
3086476106012NoneMS13Vibration dampers for LynxNos1014.01014.042.0FalseNoneNoneFalseNoneFalse42588.00
3086477106012NoneMS14P G Clamps suitable for GROUND ACSRNos403.0403.02.0FalseNoneNoneFalseNoneFalse806.00
3086478106012NoneMS15Single Tension clamps (bolted type) suitable for Ground conductorNos1234.01234.02.0FalseNoneNoneFalseNoneFalse2468.00
3086479106012NoneMS16FOR LINE-CIRCUIT BREAKER-SF-6 Gas circuit breaker with semi-pneumatic - pneumatic operated - spring type operating mechanism including mounting arrangements R bi-metallic terminal connector complete suitable for Drake ACSR and mounting structures. 110 kV, 1250 A, 31.5 KA SF6 CBNos703010.0703010.01.0FalseNoneNoneFalseNoneFalse703010.00
3086480106012NoneMS17ISOLATORS-110 kV, 1250 A, 40 KA class double break manually operated isolator with solid core insulators Upright mounting type with Earth switch.LPH 4600mmSet393250.0393250.01.0FalseNoneNoneFalseNoneFalse393250.00
3086481106012NoneMS18ISOLATORS-110 kV, 1250 A, 40 KA class double break manually operated isolator with solid core insulatorsUpright mounting type without Earth switch.LPH 4600mmSet333960.0333960.01.0FalseNoneNoneFalseNoneFalse333960.00
3086482106012NoneMS19CURRENT TRANSFORMER-Current transformer Single phase, oil filled outdoor type with R bimetallic terminal connectors suitable for drake ACSR-110 kV class, 31.5 KA, CT of ratio 400 - 200- 1-1-1A For metering- Accuracy 0.2s, Burden 10 VA For backup protection- Accuracy 5P20. Burden 30 VA For differential -Distance protection PS class (for LINES)Nos135520.0135520.03.0FalseNoneNoneFalseNoneFalse406560.00
3086483106012NoneMS20SURGE ARRESTOR (Procelain housing) metal oxide, Gapless type with R bimetallic connectors suitable for drake ACSR.96 kV, 10 KA, class - II, Heavy duty Metal oxide typeNos41140.041140.03.0FalseNoneNoneFalseNoneFalse123420.00
3086484106012NoneMS21Control and Relay Panel complete Simplex-110kV Line PanelNos640090.0640090.01.0FalseNoneNoneFalseNoneFalse640090.00
3086485106012NoneMS22STATION STRUCTURES-110 kV Station Structure fabricated out of galvanised iron. Column type 1T1 with peak. (0.956 MT per tower)Nos141931.79141931.791.0FalseNoneNoneFalseNoneFalse141931.790
3086486106012NoneMS23STATION STRUCTURES-110 kV Station Structure fabricated out of galvanised iron. Beam type 1B1(0.504 MT per tower)Nos74865.1274865.121.0FalseNoneNoneFalseNoneFalse74865.120
3086487106012NoneMS24MOUNTING STRUCTURES-110 kV Isolators. (0.76 MT per Structure)Nos112893.0112893.02.0FalseNoneNoneFalseNoneFalse225786.00
3086488106012NoneMS25MOUNTING STRUCTURES-Current transformer. 110 kV CT & 33kV NCT's, 11 kV NCT's.(0.1490 MT per Structure)Nos22133.3122133.313.0FalseNoneNoneFalseNoneFalse66399.930
3086489106012NoneMS26MOUNTING STRUCTURES-Lightening arrestors. 110 kV . (0.072 MT per Structure)Nos10697.6110697.613.0FalseNoneNoneFalseNoneFalse32092.830
3086490106012NoneMS27MOUNTING STRUCTURES-Pedestal insulators, 110 kV (0.147 MT per Structure)Nos21835.6621835.661.0FalseNoneNoneFalseNoneFalse21835.660
3086491106012NoneMS28Drake ACSR FOR BUS BAR FORMATIONMtr387.0387.0100.0FalseNoneNoneFalseNoneFalse38700.00
3086492106012NoneMS297-3.15 mm Ground wire FOR BUS BAR FORMATIONMtr88.088.050.0FalseNoneNoneFalseNoneFalse4400.00
3086493106012NoneMS30Post insulator Solid core Insulator 110 kVNos12055.012055.01.0FalseNoneNoneFalseNoneFalse12055.00
3086494106012NoneMS31Single Tension string using 8 units of each 11kV, 90 KN Disc Insulators along with Bolted Type Tension Clamp and Hardware suitalbe for LYNX ACSR (110 kV Line Side)Set6385.06385.03.0FalseNoneNoneFalseNoneFalse19155.00
3086495106012NoneMS32HARDWARES-Wedged clamp suitable for Drake-DrakeNos2336.492336.496.0FalseNoneNoneFalseNoneFalse14018.940
3086496106012NoneMS33HARDWARES-Wedged clamp suitable for Lynx -DrakeNos1946.241946.246.0FalseNoneNoneFalseNoneFalse11677.440
3086497106012NoneMS34HARDWARES-Post insulator clamp suitable for Single Drake ACSR. 127-76 mm 110 kVNos1010.01010.01.0FalseNoneNoneFalseNoneFalse1010.00
3086498106012NoneMS35PVC insulated Copper Control Cable with Lugs - Ferrules. 1.1 KV class. Size of cable 19 Core 2.5 Sq.mm. Copper Control CablesMtr525.0525.0300.0FalseNoneNoneFalseNoneFalse157500.00
3086499106012NoneMS36PVC insulated Copper Control Cable with Lugs - Ferrules. 1.1 KV class. Size of cable 2 Core 2.5 Sq.mm. Copper Control CablesMtr94.094.0500.0FalseNoneNoneFalseNoneFalse47000.00
3086500106012NoneMS37PVC insulated Copper Control Cable with Lugs - Ferrules. 1.1 KV class. Size of cable 4 Core 6.0 Sq.mm. Copper Control CablesMtr247.0247.0500.0FalseNoneNoneFalseNoneFalse123500.00
3086501106012NoneMS38PVC insulated Copper Control Cable with Lugs - Ferrules. 1.1 KV class. Size of cable 4 Core 4.0 Sq.mm. Copper Control CablesMtr177.0177.0250.0FalseNoneNoneFalseNoneFalse44250.00
3086502106012NoneMS39PVC insulated Copper Control Cable with Lugs - Ferrules. 1.1 KV class. Size of cable 4 Core 2.5 Sq.mm. Copper Control CablesMtr142.0142.0600.0FalseNoneNoneFalseNoneFalse85200.00
3086503106012NoneMS40For establishing SCADA Communication Cables-Supplying and Laying-Current Cables-Copper Core with c-s 4.0Sq.mm Multi Strand 7 CoreMtr351.14351.1450.0FalseNoneNoneFalseNoneFalse17557.00
3086504106012NoneMS41For establishing SCADA Communication Cables-Supplying and Laying-Current Cables-Copper Core with c-s 2.5Sq.mm Multi Strand 4 CoreMtr139.57139.5750.0FalseNoneNoneFalseNoneFalse6978.50
3086505106012NoneMS42For establishing SCADA Communication Cables-Supplying and Laying-Current Cables-armoured Copper Core with c-s 0.5Sq.mm Multi Strand 10 CoreMtr143.0143.050.0FalseNoneNoneFalseNoneFalse7150.00
3086506106012NoneMS43For establishing SCADA Communication Cables-Supplying and Laying-Current Cables-Copper Core with c-s 1.5 Sq.mm Multi Strand 10 CoreMtr155.0155.050.0FalseNoneNoneFalseNoneFalse7750.00
3086507106012NoneMS44For establishing SCADA Communication Cables-Supplying and Laying- One number with 8 Output points for 110kV Optocoupler mounted within the RTU panel for indication(as per market value)Nos1312.01312.01.0FalseNoneNoneFalseNoneFalse1312.00
3086508106012NoneMS45For establishing SCADA Communication Cables-Supplying and Laying- RJ-485 cable for energy meter integration (between C&R panel to RTU panel)(as per market value)Mtr30.0130.015.0FalseNoneNoneFalseNoneFalse150.050
3086509106012NoneMS46For establishing SCADA Communication Cables-Supplying and Laying- MFT for 110kV line bay(as per market value)Nos4875.04875.01.0FalseNoneNoneFalseNoneFalse4875.00
3086510106012NoneMS47For establishing SCADA Communication Cables-Supplying and Laying-Terminal Blocks(Knife Type)Nos62.5462.5460.0FalseNoneNoneFalseNoneFalse3752.40
3086511106012NoneMS48Rubber Mats 2000mm x 1000mm x 12mm size suitable for 1.1kV ClassNos3752.393752.391.0FalseNoneNoneFalseNoneFalse3752.390
3086512106012NoneMS49Equipments name plates and earthing name plates including fixing at out yardNos312.7312.76.0FalseNoneNoneFalseNoneFalse1876.20
3086513106012NoneME1Tower accessories-Circuit plateNos80.080.07.0FalseNoneNoneFalseNoneFalse560.00
3086514106012NoneME2Tower accessories-Phase plate (Set of 3 No.)Set238.0238.07.0FalseNoneNoneFalseNoneFalse1666.00
3086515106012NoneME3ACSR Lynx Conductor Plain TerrianKm8000.08000.04.933FalseNoneNoneFalseNoneFalse39464.00
3086516106012NoneME4Earth wire -7-3.15mm Ground wire Plain TerrianKm11000.011000.00.03FalseNoneNoneFalseNoneFalse330.00
3086517106012NoneME5FOR LINE-CIRCUIT BREAKER-SF-6 Gas circuit breaker with semi-pneumatic - pneumatic operated - spring type operating mechanism including mounting arrangements R bi-metallic terminal connector complete suitable for Drake ACSR and mounting structures. 110 kV, 1250 A, 31.5 KA SF6 CBNos10815.010815.01.0FalseNoneNoneFalseNoneFalse10815.00
3086518106012NoneME6ISOLATORS-110 kV, 1250 A, 40 KA class double break manually operated isolator with solid core insulators Upright mounting type with Earth switch.LPH 4600mmSet8701.08701.01.0FalseNoneNoneFalseNoneFalse8701.00
3086519106012NoneME7ISOLATORS-110 kV, 1250 A, 40 KA class double break manually operated isolator with solid core insulatorsUpright mounting type without Earth switch.LPH 4600mmSet7532.07532.01.0FalseNoneNoneFalseNoneFalse7532.00
3086520106012NoneME8CURRENT TRANSFORMER-Current transformer Single phase, oil filled outdoor type with R bimetallic terminal connectors suitable for drake ACSR-110 kV class, 31.5 KA, CT of ratio 400 - 200- 1-1-1A For metering- Accuracy 0.2s, Burden 10 VA For backup protection- Accuracy 5P20. Burden 30 VA For differential -Distance protection PS class (for LINES)Nos6394.06394.03.0FalseNoneNoneFalseNoneFalse19182.00
3086521106012NoneME9SURGE ARRESTOR (Procelain housing) metal oxide, Gapless type with R bimetallic connectors suitable for drake ACSR.96 kV, 10 KA, class - II, Heavy duty Metal oxide typeNos444.0444.03.0FalseNoneNoneFalseNoneFalse1332.00
3086522106012NoneME10Control and Relay Panel complete Simplex-110kV Line PanelNos5959.05959.01.0FalseNoneNoneFalseNoneFalse5959.00
3086523106012NoneME11STATION STRUCTURES-110 kV Station Structure fabricated out of galvanised iron. Column type 1T1 with peak. (0.956 MT per tower)Nos5723.05723.00.956FalseNoneNoneFalseNoneFalse5471.1880
3086524106012NoneME12STATION STRUCTURES-110 kV Station Structure fabricated out of galvanised iron. Beam type 1B1(0.504 MT per tower)Nos5723.05723.00.504FalseNoneNoneFalseNoneFalse2884.3920
3086525106012NoneME13MOUNTING STRUCTURES-110 kV Isolators. (0.76 MT per Structure)Nos5723.05723.01.52FalseNoneNoneFalseNoneFalse8698.960
3086526106012NoneME14MOUNTING STRUCTURES-Current transformer. 110 kV CT & 33kV NCT's, 11 kV NCT's.(0.1490 MT per Structure)Nos5723.05723.00.447FalseNoneNoneFalseNoneFalse2558.1810
3086527106012NoneME15MOUNTING STRUCTURES-Lightening arrestors. 110 kV . (0.072 MT per Structure)Nos5723.05723.00.216FalseNoneNoneFalseNoneFalse1236.1680
3086528106012NoneME16MOUNTING STRUCTURES-Pedestal insulators. 110 kV(0.147 MT per Structure)Nos5723.05723.00.147FalseNoneNoneFalseNoneFalse841.2810
3086529106012NoneME17Drake ACSR FOR BUS BAR FORMATIONMtr13.3313.33100.0FalseNoneNoneFalseNoneFalse1333.00
3086530106012NoneME187-3.15 mm Ground wire FOR BUS BAR FORMATIONMtr11.011.050.0FalseNoneNoneFalseNoneFalse550.00
3086531106012NoneME19Formation of Main-Cross bus on 110kV side with single Drake FOR BUS BAR FORMATION per bayNos12087.012087.01.0FalseNoneNoneFalseNoneFalse12087.00
3086532106012NoneME20Faraday Cage formation as per specification for 110kV FOR BUS BAR FORMATION per bayNos200.0200.01.0FalseNoneNoneFalseNoneFalse200.00
3086533106012NoneME21Post insulator Solid core Insulator 110 kVNos444.0444.01.0FalseNoneNoneFalseNoneFalse444.00
3086534106012NoneME22PVC insulated Copper Control Cable with Lugs - Ferrules. 1.1 KV class. Size of cable 19 Core 2.5 Sq.mm. Copper Control CablesMtr15.015.0300.0FalseNoneNoneFalseNoneFalse4500.00
3086535106012NoneME23PVC insulated Copper Control Cable with Lugs - Ferrules. 1.1 KV class. Size of cable 2 Core 2.5 Sq.mm. Copper Control CablesMtr15.015.0500.0FalseNoneNoneFalseNoneFalse7500.00
3086536106012NoneME24PVC insulated Copper Control Cable with Lugs - Ferrules. 1.1 KV class. Size of cable 4 Core 6.0 Sq.mm. Copper Control CablesMtr15.015.0500.0FalseNoneNoneFalseNoneFalse7500.00
3086537106012NoneME25PVC insulated Copper Control Cable with Lugs - Ferrules. 1.1 KV class. Size of cable 4 Core 4.0 Sq.mm. Copper Control CablesMtr15.015.0250.0FalseNoneNoneFalseNoneFalse3750.00
3086538106012NoneME26PVC insulated Copper Control Cable with Lugs - Ferrules. 1.1 KV class. Size of cable 4 Core 2.5 Sq.mm. Copper Control CablesMtr15.015.0600.0FalseNoneNoneFalseNoneFalse9000.00
3086539106012NoneME27For establishing SCADA Communication Cables-Supplying and Laying-Current Cables-Copper Core with c-s 4.0Sq.mm Multi Strand 7 CoreMtr15.015.050.0FalseNoneNoneFalseNoneFalse750.00
3086540106012NoneME28For establishing SCADA Communication Cables-Supplying and Laying-Current Cables-Copper Core with c-s 2.5Sq.mm Multi Strand 4 CoreMtr15.015.050.0FalseNoneNoneFalseNoneFalse750.00
3086541106012NoneME29For establishing SCADA Communication Cables-Supplying and Laying-Current Cables-armoured Copper Core with c-s 0.5Sq.mm Multi Strand 10 CoreMtr15.015.050.0FalseNoneNoneFalseNoneFalse750.00
3086542106012NoneME30For establishing SCADA Communication Cables-Supplying and Laying-Current Cables-Copper Core with c-s 1.5 Sq.mm Multi Strand 10 CoreMtr15.015.050.0FalseNoneNoneFalseNoneFalse750.00
3086543106012NoneME31For establishing SCADA Communication Cables-Supplying and Laying- One number with 8 Output points for 110kV Optocoupler mounted within the RTU panel for indication(as per market value)Nos1555.01555.01.0FalseNoneNoneFalseNoneFalse1555.00
3086544106012NoneME32For establishing SCADA Communication Cables-Supplying and Laying- RJ-485 cable for energy meter integration (between C&R panel to RTU panel)(as per market value)Mtr25.025.05.0FalseNoneNoneFalseNoneFalse125.00
3086545106012NoneME33Earth Mat formation-Grounding of equipments with 50 x 6 mm G I flat and connecting equipments to the earth mat-ground pit including all connected works with all materials supplied by the contractor.Mtr335.0335.0275.0FalseNoneNoneFalseNoneFalse92125.00
3086546106012NoneME34Excavation, formation, refilling for earth matCUBIC METER368.0368.054.0FalseNoneNoneFalseNoneFalse19872.00
3086547106012NoneME35Providing C.I. Pipe of 100mm ID 13mm thick 2.75 mtr. long with 2 part GI Flat 50x6mm clamp welded allround the pipe etc., including cost of excavation (all materials supplied by contractor)Set16283.016283.03.0FalseNoneNoneFalseNoneFalse48849.00
3086548106012NoneME36Supplying and fixing 450mm dia x 450mm height 1.5Inch to 2Inch Hume pipe collars for earth pits.Nos1499.01499.03.0FalseNoneNoneFalseNoneFalse4497.00
3086549106012NoneYT1FOR LINE-CIRCUIT BREAKER-SF-6 Gas circuit breaker with semi-pneumatic - pneumatic operated - spring type operating mechanism including mounting arrangements R bi-metallic terminal connector complete suitable for Drake ACSR and mounting structures. 110 kV, 1250 A, 31.5 KA SF6 CBNos33813.033813.01.0FalseNoneNoneFalseNoneFalse33813.00
3086550106012NoneYT2ISOLATORS-110 kV, 1250 A, 40 KA class double break manually operated isolator with solid core insulators Upright mounting type with Earth switch.LPH 4600mmSet1301.01301.01.0FalseNoneNoneFalseNoneFalse1301.00
3086551106012NoneYT3ISOLATORS-110 kV, 1250 A, 40 KA class double break manually operated isolator with solid core insulatorsUpright mounting type without Earth switch.LPH 4600mmSet1252.01252.01.0FalseNoneNoneFalseNoneFalse1252.00
3086552106012NoneYT4CURRENT TRANSFORMER-Current transformer Single phase, oil filled outdoor type with R bimetallic terminal connectors suitable for drake ACSR-110 kV class, 31.5 KA, CT of ratio 400 - 200- 1-1-1A For metering- Accuracy 0.2s, Burden 10 VA For backup protection- Accuracy 5P20. Burden 30 VA For differential -Distance protection PS class (for LINES)Nos.4260.04260.03.0FalseNoneNoneFalseNoneFalse12780.00
3086553106012NoneYT5Control and Relay Panel complete Simplex-110kV Line PanelNos.36425.036425.01.0FalseNoneNoneFalseNoneFalse36425.00
3086554106012NoneCE1110 kV Station Structure fabricated out of galvanised iron. Column type 1T1 with peak. 0.956 MT per tower)Nos.85969.085969.01.0FalseNoneNoneFalseNoneFalse85969.00
3086555106012NoneCE2Foundation- Engineering supplyof all labours, materials and construction of RCC Footings of any depth, pedestals including the cost of Excavation, Concreting, Cement, Reinforcement steel for all the works, Grouting, under pinning etc., for the following station towers and mounitng structures. for 110kV, 1250A, 40KA, SF6, CBNos.79160.079160.01.0FalseNoneNoneFalseNoneFalse79160.00
3086556106012NoneCE3Foundation- Engineering supplyof all labours, materials and construction of RCC Footings of any depth, pedestals including the cost of Excavation, Concreting, Cement, Reinforcement steel for all the works, Grouting, under pinning etc., for the following station towers and mounitng structures. for 110 kV Isolators. (0.760 MT per Structure)Nos.31604.031604.02.0FalseNoneNoneFalseNoneFalse63208.00
3086557106012NoneCE4Foundation- Engineering supplyof all labours, materials and construction of RCC Footings of any depth, pedestals including the cost of Excavation, Concreting, Cement, Reinforcement steel for all the works, Grouting, under pinning etc., for the following station towers and mounitng structures. for Current transformer. 110 kV CT & 11 kV NCT's.(0.149 MT per Structure)Nos.16307.016307.03.0FalseNoneNoneFalseNoneFalse48921.00
3086558106012NoneCE5Foundation- Engineering supplyof all labours, materials and construction of RCC Footings of any depth, pedestals including the cost of Excavation, Concreting, Cement, Reinforcement steel for all the works, Grouting, under pinning etc., for the following station towers and mounitng structures. For Lightening arrestors. 110 kV . (0.1400 MT per Structure)Nos.9800.09800.03.0FalseNoneNoneFalseNoneFalse29400.00
3086559106012NoneCE6Foundation- Engineering supplyof all labours, materials and construction of RCC Footings of any depth, pedestals including the cost of Excavation, Concreting, Cement, Reinforcement steel for all the works, Grouting, under pinning etc., for the following station towers and mounitng structures. For Pedestal insulators. 110 kV . (0.1500 MT per Structure)Nos.9387.09387.01.0FalseNoneNoneFalseNoneFalse9387.00
3086560106012NoneCE7Jelly spreading- Providing and spreading 20-25 mm jelly in station yard including conveying, stacking for measurement, spreading in layer of 100 mm over all.Sqm177.3177.3300.0FalseNoneNoneFalseNoneFalse53190.00
3086561106012NoneCE8Cable ducts - Construction of RCC Main Cable duct with 2 nos of NP2 Pipe with internal dimension 450 x 450 mm as per Technical specification design and drawings. including material, cement, steel, flats.Mtr1404.01404.025.0FalseNoneNoneFalseNoneFalse35100.00
3086562106012NoneCE9Cable ducts - Construction of RCC Main Cable duct with 1 nos of NP2 Pipe with internal dimension 450 x 450 mm as per Technical specification design and drawings. including material, cement, steel, flats.Mtr725.0725.050.0FalseNoneNoneFalseNoneFalse36250.00
3086563106012NoneCE10Inspection Chambers Construction of Brick masonary inspection chamber with cast iron cover of size 600 x 450 mm as per technical specification design and drawingNos.7416.07416.05.0FalseNoneNoneFalseNoneFalse37080.00
3086564106012NoneCE11Inspection Chambers- Providing Inspection Chambers of Size 450x450mm with Cast iron Covers as per specificationNos.6198.06198.05.0FalseNoneNoneFalseNoneFalse30990.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17104889550000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17104889550000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17104889550000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNonea)Should have carried out Erection of One station of 66KV class or above category on Total Turnkey or Partial Turnkey basis, having at least two nos. of Circuit Breaker, Terminal Bays (out of which at least one must be Transformer Bay including erection of Transformer) which shall be in satisfactory service for a period of One year prior to date of submission of the Bid. OR b)Should have constructed 66KV Transmission Line or above category on Total Turnkey basis or Partial Turnkey basis to an extent equivalent to the length of the line proposed in the tender or to an extent of 5kmswhich ever is less in the last Seven years preceding the date of Bid submission, out of which HALF of the above quantity or 3Km whichever is less shall be in satisfactory service for a period of One year prior to the date of submission of the Bid. OR c)Should have carried out of 66kV class or above class of breaker replacement work on Total Turnkey basis or Partial Turnkey basis or Labour contract basis and shall be in satisfactory service for a period of One yearPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneThe Bidder should possess valid Super Grade Electrical Contractors License issued by the Government of Karnataka as on the date of opening of bid.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- The Bidder should possess valid Super Grade Electrical Contractors License issued by the Government of Karnataka as on the date of opening of bid.
NoneNoneNoneNoneGST registration certificate AND PAN CARDCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneEPF REGISTRATION CERTIFICATE ISSUED BY CONCERNEDCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneValid EPF Certificate
NoneNoneNoneNoneESI REGISTRATION CERTIFICATECapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneValid ESI certificate
NoneNoneNoneNoneLABOUR REGISTRATION CERTIFICATE ISSUED BY DEPARTMENT OF LABOUR/DICCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLabour Certificate
NoneNoneNoneNoneMinimum Average Annual Turnover (MAAT) of the bidder for best three years out of last five financial years ending on March or December as the case may be, shall not be less than 1.5 times amount tenderFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneConsortium Agreement if applicable,OthersConsortium Agreement if applicable,
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Consortium Agreement if applicable,
NoneNoneNoneNonePower of Attorney in favor of all the persons signing the documents (If applicable),OthersPOWER OF ATTORNY
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Power of Attorney in favor of all the persons signing the documents (If applicable),
NoneNoneNoneNoneNo Deviation SELF declarationOthersNo Deviation SELF declaration
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- No Deviation SELF declaration
NoneNoneNoneNoneLetter of UndertakingOthersLetter of Undertaking
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Letter of Undertaking
NoneNoneNoneNoneSelf declaration non block listing from any government organizationOthersSelf declaration non block listing from any government organization
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Self declaration non block listing from any government organization
NoneNoneNoneNoneSelf declaration No litigation with KPTCLOthersSelf declaration No litigation with KPTCL
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Self declaration No litigation with KPTCL
NoneNoneNoneNoneDetails of works on hand with award cost, self-declarationOthersDetails of works on hand with award cost, self-declaration
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Details of works on hand with award cost, self-declaration
NoneNoneNoneNoneTechno commercial Sheets duly filled in ENCLOSED FORMATOthersTECHNO-COMMERCIAL SHEET
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Techno commercial Sheets duly filled in ENCLOSED FORMAT
NoneNoneNoneNoneAny other documents required as per QROthersQR AS PER NIT
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Any other documents required as per QR
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateFalseTechnical Bid
Company Registration CertificateFalseTechnical Bid
Reserved Category CertificateFalseTechnical Bid
Small Scale Industries CertificateFalseTechnical Bid
Any other documents required as per QRTrueTechnical Bid
Consortium Agreement if applicable,FalseTechnical Bid
DETAILS OF ON HAND WORKS WITH AWARD COST SELF DECLARATIONTrueTechnical Bid
ESI REGISTRATION CERTIFICATETrueTechnical Bid
EPF REGISTRATION CERTIFICATE ISSUED BY CONCERNEDTrueTechnical Bid
GST registration certificate AND PAN CARDTrueTechnical Bid
LABOUR REGISTRATION CERTIFICATE ISSUED BY DEPARTMENT OF LABOUR/DICTrueTechnical Bid
Letter of UndertakingTrueTechnical Bid
Minimum Average Annual Turnover MAAT of the bidder for best three years out of last five financial years ending on March or December as the case may be, shall not be less than 1.5 times amount tenderTrueTechnical Bid
No Deviation declarationTrueTechnical Bid
Power of Attorney in favor of all the persons signing the documents ,If applicableFalseTechnical Bid
Self declaration non block listing from any government organizationTrueTechnical Bid
Self declaration No litigation with KPTCLTrueTechnical Bid
Techno commercial Sheets duly filled in ENCLOSED FORMATTrueTechnical Bid
The Bidder should possess valid Super Grade Electrical Contractors License issued by the Government of Karnataka as on the date of opening of bidTrueTechnical Bid
WORK DONE AS PER NIT QRTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1710497588000
version0
createdDateNone
modifiedDateNone
blockNumberOFFICE OF THE SUPERITENDING ENGINEER ELE, TANSMISSION W AND M CIRCLE KPTCL MUNIRABAD, KOPPAL DISTRICT
streetNone
cityMUNIRABAD
stateKarnataka
pin583233
tenderRecallDTONone