2979876 | 98809 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M25 Design Mix Using 20 mm nominal size graded crushed coarse
aggregates | Cum | 7328.85 | 7328.85 | 333.32 | False | None | None | False | None | False | 2442852.282 | 0 |
2979877 | 98809 | None | 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse
aggregates | Cum | 7100.73 | 7100.73 | 1.68 | False | None | None | False | None | False | 11929.2264 | 0 |
2979878 | 98809 | None | 6.31 | Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks as per IS 2185 (Part III) in super structure above plinth level up to floor I level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8544.44 | 8544.44 | 199.1 | False | None | None | False | None | False | 1701198.004 | 0 |
2979879 | 98809 | None | 6.26 | Providing and laying Autoclaved Aerated Cement blocks masonry with 100 mm thick AAC blocks as per IS 2185 (Part III) in super structure above plinth level up to floor I level in cement mortar 1:4 (1 cement : 4 coarse sand ) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
| Cum | 9164.55 | 9164.55 | 7.29 | False | None | None | False | None | False | 66809.5695 | 0 |
2979880 | 98809 | None | 8.16.2 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 150mm wide | m | 38.0 | 38.0 | 3089.68 | False | None | None | False | None | False | 117407.84 | 0 |
2979881 | 98809 | None | 8.1.2 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 258.11 | 258.11 | 1857.52 | False | None | None | False | None | False | 479444.4872 | 0 |
2979882 | 98809 | None | 8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 273.11 | 273.11 | 1185.12 | False | None | None | False | None | False | 323668.1232 | 0 |
2979883 | 98809 | None | 8.9 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 412.34 | 412.34 | 728.3 | False | None | None | False | None | False | 300307.222 | 0 |
2979884 | 98809 | None | 8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge
| Sqm | 315.95 | 315.95 | 355.8 | False | None | None | False | None | False | 112415.01 | 0 |
2979885 | 98809 | None | 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.
| Sqm | 107.1 | 107.1 | 3042.64 | False | None | None | False | None | False | 325866.744 | 0 |
2979886 | 98809 | None | 8.3 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 186.35 | 186.35 | 728.3 | False | None | None | False | None | False | 135718.705 | 0 |
2979887 | 98809 | None | 8.39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer
| Sqm | 136.02 | 136.02 | 1857.52 | False | None | None | False | None | False | 252659.8704 | 0 |
2979888 | 98809 | None | 8.39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer
| Sqm | 136.02 | 136.02 | 1185.12 | False | None | None | False | None | False | 161200.0224 | 0 |
2979889 | 98809 | None | 9.30 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1.3 over existing cement concrete bed , including cost of materials, mortar, labor, curing complete as per specifications. | Sqm | 5706.29 | 5706.29 | 55.66 | False | None | None | False | None | False | 317612.1014 | 0 |
2979890 | 98809 | None | 9.24 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.
| Sqm | 3054.49 | 3054.49 | 304.6 | False | None | None | False | None | False | 930397.654 | 0 |
2979891 | 98809 | None | 10.18 | Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 (1 cement : 3 coarse sand) proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar, labour, curing etc., complete
| Sqm | 3597.49 | 3597.49 | 324.51 | False | None | None | False | None | False | 1167421.4799 | 0 |
2979892 | 98809 | None | 9.17.3 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete Size of Tile 800x800 mm
| Sqm | 1378.38 | 1378.38 | 801.93 | False | None | None | False | None | False | 1105364.2734 | 0 |
2979893 | 98809 | None | 9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete | Sqm | 952.12 | 952.12 | 55.52 | False | None | None | False | None | False | 52861.7024 | 0 |
2979894 | 98809 | None | 10.14 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg/m2, including pointing in white cement mixed with pigment of matching shade complete.
| Sqm | 1184.53 | 1184.53 | 222.72 | False | None | None | False | None | False | 263818.5216 | 0 |
2979895 | 98809 | None | 10.1.2 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Area of slab over 0.50 m2
| Sqm | 4216.53 | 4216.53 | 6.03 | False | None | None | False | None | False | 25425.6759 | 0 |
2979896 | 98809 | None | 12.11 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.
| Cum | 147877.25 | 147877.25 | 1.443 | False | None | None | False | None | False | 213386.87175 | 0 |
2979897 | 98809 | None | 12.57.7 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.
| Sqm | 5312.16 | 5312.16 | 42.12 | False | None | None | False | None | False | 223748.1792 | 0 |
2979898 | 98809 | None | 12.54 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge
| Sqm | 340.58 | 340.58 | 17.01 | False | None | None | False | None | False | 5793.2658 | 0 |
2979899 | 98809 | None | 12.55.1 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges
| Sqm | 2533.99 | 2533.99 | 17.01 | False | None | None | False | None | False | 43103.1699 | 0 |
2979900 | 98809 | None | 12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications
| Nos | 1088.14 | 1088.14 | 12.0 | False | None | None | False | None | False | 13057.68 | 0 |
2979901 | 98809 | None | 12.90 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made | Sqm | 7212.11 | 7212.11 | 62.37 | False | None | None | False | None | False | 449819.3007 | 0 |
2979902 | 98809 | None | 12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)
| Sqm | 6125.05 | 6125.05 | 17.7 | False | None | None | False | None | False | 108413.385 | 0 |
2979903 | 98809 | None | 11.34B | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.
| Kg | 195.99 | 195.99 | 1681.47 | False | None | None | False | None | False | 329551.3053 | 0 |
2979904 | 98809 | None | 8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 123.17 | 123.17 | 80.07 | False | None | None | False | None | False | 9862.2219 | 0 |
2979905 | 98809 | None | 8.55.1 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 g/L as per specifications and as per directions of Engineer in charge.
| Sqm | 59.98 | 59.98 | 101.09 | False | None | None | False | None | False | 6063.3782 | 0 |
2979906 | 98809 | None | 8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 123.17 | 123.17 | 101.09 | False | None | None | False | None | False | 12451.2553 | 0 |
2979907 | 98809 | None | 11.28 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
| Kg | 605.12 | 605.12 | 553.08 | False | None | None | False | None | False | 334679.7696 | 0 |
2979908 | 98809 | None | 15.1 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400perc and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geotextile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification | Sqm | 875.01 | 875.01 | 55.52 | False | None | None | False | None | False | 48580.5552 | 0 |
2979909 | 98809 | None | 7.18 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.
| Cum | 2160.21 | 2160.21 | 33.32 | False | None | None | False | None | False | 71978.1972 | 0 |
2979910 | 98809 | None | 037 | providing & fxing Godrej lock
| Nos | 1850.0 | 1850.0 | 16.0 | False | None | None | False | None | False | 29600.0 | 0 |
2979911 | 98809 | None | 038 | providing & fxing Brass/Antique Handle
| Nos | 2000.0 | 2000.0 | 14.0 | False | None | None | False | None | False | 28000.0 | 0 |
2979912 | 98809 | None | 039 | providing & fixing SS/Antique Bolt 300mm long
| Nos | 600.0 | 600.0 | 28.0 | False | None | None | False | None | False | 16800.0 | 0 |
2979913 | 98809 | None | 040 | providing & fixing SS/Antique hinges 8" heavy duty
| Nos | 350.0 | 350.0 | 112.0 | False | None | None | False | None | False | 39200.0 | 0 |
2979914 | 98809 | None | 041 | providing & fixing MS holdfast
| Nos | 250.0 | 250.0 | 112.0 | False | None | None | False | None | False | 28000.0 | 0 |
2979915 | 98809 | None | 042 | providing & fixing magnetic catch
| Nos | 750.0 | 750.0 | 28.0 | False | None | None | False | None | False | 21000.0 | 0 |
2979916 | 98809 | None | 043 | providing & fixing SS/Antique alldrop
| Nos | 1850.0 | 1850.0 | 14.0 | False | None | None | False | None | False | 25900.0 | 0 |
2979917 | 98809 | None | 044 | providing & fixing door closure
| Nos | 3000.0 | 3000.0 | 14.0 | False | None | None | False | None | False | 42000.0 | 0 |
2979918 | 98809 | None | 045 | providing & fixing door stopper
| Nos | 750.0 | 750.0 | 14.0 | False | None | None | False | None | False | 10500.0 | 0 |
2979919 | 98809 | None | 046 | Brass screws of various sizes
| Nos | 15.0 | 15.0 | 1008.0 | False | None | None | False | None | False | 15120.0 | 0 |
2979920 | 98809 | None | 047 | Nails of Varying Sizes
| Kgs | 110.0 | 110.0 | 50.0 | False | None | None | False | None | False | 5500.0 | 0 |
2979921 | 98809 | None | 11.35.2.2 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-incharge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications.
| Kgs | 611.54 | 611.54 | 608.4 | False | None | None | False | None | False | 372060.936 | 0 |
2979922 | 98809 | None | 11.37.2 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m²) including cost of materials, labour, usage charges of machinery complete as per specifications.
| Sqm | 1254.14 | 1254.14 | 9.0 | False | None | None | False | None | False | 11287.26 | 0 |
2979923 | 98809 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse
aggregates"
| Cum | 7400.7 | 7400.7 | 51.99 | False | None | None | False | None | False | 384762.393 | 0 |
2979924 | 98809 | None | 2.1.4 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications.
| Cum | 6723.69 | 6723.69 | 8.08 | False | None | None | False | None | False | 54327.4152 | 0 |
2979925 | 98809 | None | 2.1.4 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications.
| Cum | 6723.69 | 6723.69 | 4.64 | False | None | None | False | None | False | 31197.9216 | 0 |
2979926 | 98809 | None | 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications
| Cum | 7170.35 | 7170.35 | 0.46 | False | None | None | False | None | False | 3298.361 | 0 |
2979927 | 98809 | None | 6.31 | Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks as per IS 2185 (Part III) in super structure above plinth level up to floor I level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
| Cum | 8628.21 | 8628.21 | 61.36 | False | None | None | False | None | False | 529426.9656 | 0 |
2979928 | 98809 | None | 8.16.2 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for paymentPlaster mesh 150mm wide
| m | 38.0 | 38.0 | 538.12 | False | None | None | False | None | False | 20448.56 | 0 |
2979929 | 98809 | None | 8.1.2 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 260.64 | 260.64 | 103.77 | False | None | None | False | None | False | 27046.6128 | 0 |
2979930 | 98809 | None | 8.9 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge
| Sqm | 416.38 | 416.38 | 1279.35 | False | None | None | False | None | False | 532695.753 | 0 |
2979931 | 98809 | None | 8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 275.78 | 275.78 | 161.52 | False | None | None | False | None | False | 44543.9856 | 0 |
2979932 | 98809 | None | 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.
| Sqm | 108.15 | 108.15 | 265.29 | False | None | None | False | None | False | 28691.1135 | 0 |
2979933 | 98809 | None | 8.30 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 188.18 | 188.18 | 1279.35 | False | None | None | False | None | False | 240748.083 | 0 |
2979934 | 98809 | None | 8.39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer
| Sqm | 137.35 | 137.35 | 103.77 | False | None | None | False | None | False | 14252.8095 | 0 |
2979935 | 98809 | None | 8.39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer
| Sqm | 137.35 | 137.35 | 161.52 | False | None | None | False | None | False | 22184.772 | 0 |
2979936 | 98809 | None | 9.17.3 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.
| Sqm | 1391.89 | 1391.89 | 96.62 | False | None | None | False | None | False | 134484.4118 | 0 |
2979937 | 98809 | None | 12.11 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.
| Cum | 149327.03 | 149327.03 | 0.139 | False | None | None | False | None | False | 20756.45717 | 0 |
2979938 | 98809 | None | 12.57.7 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 40 mm thick both side Teak
| Sqm | 5364.24 | 5364.24 | 5.04 | False | None | None | False | None | False | 27035.7696 | 0 |
2979939 | 98809 | None | 12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.
| Nos | 1098.8 | 1098.8 | 2.0 | False | None | None | False | None | False | 2197.6 | 0 |
2979940 | 98809 | None | 12.90 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made)
| Sqm | 7282.82 | 7282.82 | 5.94 | False | None | None | False | None | False | 43259.9508 | 0 |
2979941 | 98809 | None | 11.34B | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc
| Kg | 197.91 | 197.91 | 124.74 | False | None | None | False | None | False | 24687.2934 | 0 |
2979942 | 98809 | None | 8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 124.37 | 124.37 | 5.94 | False | None | None | False | None | False | 738.7578 | 0 |
2979943 | 98809 | None | 8.55.1 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 g/L as per specifications and as per directions of Engineer in charge.
| Sqm | 60.56 | 60.56 | 12.1 | False | None | None | False | None | False | 732.776 | 0 |
2979944 | 98809 | None | 8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 124.37 | 124.37 | 12.1 | False | None | None | False | None | False | 1504.877 | 0 |
2979945 | 98809 | None | 15.1 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400perc and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geotextile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification.
| Sqm | 888.59 | 888.59 | 1261.32 | False | None | None | False | None | False | 1120796.3388 | 0 |
2979946 | 98809 | None | 15.6 | Providing and laying water proofing treatment to the Water tanks & Liquid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50% applied @ 1.5 kg/m2 for internal side waterproofing in two layers with waiting period of 4-6 hrs per layer and food grade epoxy coating in two coats certified by CFTRI Mysuru, including surface preparation completely as per specification.
| Sqm | 548.32 | 548.32 | 64.16 | False | None | None | False | None | False | 35180.2112 | 0 |
2979947 | 98809 | None | 9.25 | Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
| Sqm | 840.0 | 840.0 | 400.0 | False | None | None | False | None | False | 336000.0 | 0 |
2979948 | 98809 | None | 2.1.4 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6527.85 | 6527.85 | 73.21 | False | None | None | False | None | False | 477903.8985 | 0 |
2979949 | 98809 | None | 19.3 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineerincharge. | Cum | 2547.3 | 2547.3 | 67.2 | False | None | None | False | None | False | 171178.56 | 0 |
2979950 | 98809 | None | 19.7.3 | Demolishing brick work manually/ by mechanical means including stack ing of serviceable material and disposal of unserviceable material to the
appropriate disposal area as per direction of Engineerincharge. In cement mortar
| Cum | 1080.45 | 1080.45 | 65.89 | False | None | None | False | None | False | 71190.8505 | 0 |
2979951 | 98809 | None | 19.61 | Dismantling weather proof course and removing and conveying the debris to a distance to the appropriate disposal area as per direction of Engineer-in-charge.
| Cum | 604.8 | 604.8 | 126.13 | False | None | None | False | None | False | 76283.424 | 0 |
2979952 | 98809 | None | 2.2.1 | Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral)
& 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to IS-694: and latest amendments) without
control switch shall be fixed on the existing plastic sheet/ gang box,
the other end of the wires shall be terminated with sufficient loose
length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box
| Point | 269.0 | 269.0 | 6.0 | False | None | None | False | None | False | 1614.0 | 0 |
2979953 | 98809 | None | 2.2.2 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet Medium point above 3Mtr upto 6Mtr from tapping point to out let via
switch box"
| Point | 379.0 | 379.0 | 15.0 | False | None | None | False | None | False | 5685.0 | 0 |
2979954 | 98809 | None | 2.2.3 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to out let via
switch box"
| Point | 555.0 | 555.0 | 32.0 | False | None | None | False | None | False | 17760.0 | 0 |
2979955 | 98809 | None | 2.2.4 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr upto 6Mtr from tapping point to out
let via switches"
| Point | 677.0 | 677.0 | 24.0 | False | None | None | False | None | False | 16248.0 | 0 |
2979956 | 98809 | None | 3.4.1 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2 Way
| Each | 138.0 | 138.0 | 10.0 | False | None | None | False | None | False | 1380.0 | 0 |
2979957 | 98809 | None | 3.4.2 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3 Way
| Each | 159.0 | 159.0 | 30.0 | False | None | None | False | None | False | 4770.0 | 0 |
2979958 | 98809 | None | 3.4.3 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5 Way
| Each | 177.0 | 177.0 | 18.0 | False | None | None | False | None | False | 3186.0 | 0 |
2979959 | 98809 | None | 3.4.4 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6 Way
| Each | 220.0 | 220.0 | 36.0 | False | None | None | False | None | False | 7920.0 | 0 |
2979960 | 98809 | None | 3.4.5 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way
| Each | 261.0 | 261.0 | 10.0 | False | None | None | False | None | False | 2610.0 | 0 |
2979961 | 98809 | None | 3.4.6 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12 Way
| Each | 319.0 | 319.0 | 12.0 | False | None | None | False | None | False | 3828.0 | 0 |
2979962 | 98809 | None | 3.4.7 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 16 Way
| Each | 363.0 | 363.0 | 10.0 | False | None | None | False | None | False | 3630.0 | 0 |
2979963 | 98809 | None | 3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 1 to 2 Module
| Each | 137.0 | 137.0 | 10.0 | False | None | None | False | None | False | 1370.0 | 0 |
2979964 | 98809 | None | 3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 3 Module
| Each | 161.0 | 161.0 | 30.0 | False | None | None | False | None | False | 4830.0 | 0 |
2979965 | 98809 | None | 3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 4 Module
| Each | 175.0 | 175.0 | 18.0 | False | None | None | False | None | False | 3150.0 | 0 |
2979966 | 98809 | None | 3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 6 Module
| Each | 234.0 | 234.0 | 36.0 | False | None | None | False | None | False | 8424.0 | 0 |
2979967 | 98809 | None | 3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 8 Module
| Each | 284.0 | 284.0 | 10.0 | False | None | None | False | None | False | 2840.0 | 0 |
2979968 | 98809 | None | 3.5.6 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 10-12 Module
| Each | 344.0 | 344.0 | 12.0 | False | None | None | False | None | False | 4128.0 | 0 |
2979969 | 98809 | None | 3.5.7 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 16 Module
| Kg | 397.0 | 397.0 | 10.0 | False | None | None | False | None | False | 3970.0 | 0 |
2979970 | 98809 | None | 3.6.1 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch
| Each | 102.0 | 102.0 | 118.0 | False | None | None | False | None | False | 12036.0 | 0 |
2979971 | 98809 | None | 3.6.2 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Two Way Switch
| Each | 166.0 | 166.0 | 8.0 | False | None | None | False | None | False | 1328.0 | 0 |
2979972 | 98809 | None | 3.6.4 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two Module
| Each | 357.0 | 357.0 | 30.0 | False | None | None | False | None | False | 10710.0 | 0 |
2979973 | 98809 | None | 3.6.10 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16A Universal Socket
| Each | 236.0 | 236.0 | 10.0 | False | None | None | False | None | False | 2360.0 | 0 |
2979974 | 98809 | None | 3.6.7 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16A One Way Switch
| Each | 180.0 | 180.0 | 10.0 | False | None | None | False | None | False | 1800.0 | 0 |
2979975 | 98809 | None | 3.6.9 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32A DP Switch
| Each | 326.0 | 326.0 | 2.0 | False | None | None | False | None | False | 652.0 | 0 |
2979976 | 98809 | None | 3.6.8 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Bell Push
| Each | 177.0 | 177.0 | 4.0 | False | None | None | False | None | False | 708.0 | 0 |
2979977 | 98809 | None | 12.2.1 | Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell
| Each | 246.0 | 246.0 | 4.0 | False | None | None | False | None | False | 984.0 | 0 |
2979978 | 98809 | None | 13.12 | Extra length of GI pipe of class B 19mm dia for down rod.
| m | 197.0 | 197.0 | 30.0 | False | None | None | False | None | False | 5910.0 | 0 |
2979979 | 98809 | None | 1.13 | Supplying And Fixing Metal Fan Box with Round Hook.
| No | 117.0 | 117.0 | 30.0 | False | None | None | False | None | False | 3510.0 | 0 |
2979980 | 98809 | None | 1.2.1 | Supplying heavy gauge PVC conduit pipe . mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2 mm thick
| m | 66.0 | 66.0 | 2305.0 | False | None | None | False | None | False | 152130.0 | 0 |
2979981 | 98809 | None | 1.2.2 | Supplying heavy gauge PVC conduit pipe . mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25 mm dia 2 mm thick
| m | 78.0 | 78.0 | 1822.0 | False | None | None | False | None | False | 142116.0 | 0 |
2979982 | 98809 | None | 1.2.3 | Supplying heavy gauge PVC conduit pipe . mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 32 mm dia 2.5 mm thick
| m | 103.0 | 103.0 | 53.0 | False | None | None | False | None | False | 5459.0 | 0 |
2979983 | 98809 | None | 1.3.1 | Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19/20 mm dia 2 mm thick
| m | 68.0 | 68.0 | 440.0 | False | None | None | False | None | False | 29920.0 | 0 |
2979984 | 98809 | None | 1.3.2 | Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25 mm dia 2 mm thick
| m | 79.0 | 79.0 | 285.0 | False | None | None | False | None | False | 22515.0 | 0 |
2979985 | 98809 | None | 1.3.3 | Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 32 mm dia 2.5 mm thick
| m | 99.0 | 99.0 | 100.0 | False | None | None | False | None | False | 9900.0 | 0 |
2979986 | 98809 | None | 1.5.1 | Supplying and fixing PVC/metal conduit Deep junction box 32 mm dia 2.5 mm thick
| Each | 49.0 | 49.0 | 116.0 | False | None | None | False | None | False | 5684.0 | 0 |
2979987 | 98809 | None | 1.5.2 | Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction box
| Each | 56.0 | 56.0 | 132.0 | False | None | None | False | None | False | 7392.0 | 0 |
2979988 | 98809 | None | 1.5.3 | Supplying and fixing PVC/metal conduit Deep junction box 32 mm deep Junction box
| Each | 61.0 | 61.0 | 22.0 | False | None | None | False | None | False | 1342.0 | 0 |
2979989 | 98809 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 mm2
| m | 26.0 | 26.0 | 2150.0 | False | None | None | False | None | False | 55900.0 | 0 |
2979990 | 98809 | None | 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:20102.5 mm2
| m | 42.0 | 42.0 | 3300.0 | False | None | None | False | None | False | 138600.0 | 0 |
2979991 | 98809 | None | 2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 4 mm2
| m | 63.0 | 63.0 | 1380.0 | False | None | None | False | None | False | 86940.0 | 0 |
2979992 | 98809 | None | 2.3.5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 6 mm2
| m | 92.0 | 92.0 | 220.0 | False | None | None | False | None | False | 20240.0 | 0 |
2979993 | 98809 | None | 121 | Supplyng tinned copper lugs and crimping and wiring to terminal point for wire fo 1.5 sqmm
| Each | 3.0 | 3.0 | 116.0 | False | None | None | False | None | False | 348.0 | 0 |
2979994 | 98809 | None | 122 | Supplyng tinned copper lugs and crimping and wiring to terminal point for wire fo 2.5 sqmm
| Each | 4.0 | 4.0 | 129.0 | False | None | None | False | None | False | 516.0 | 0 |
2979995 | 98809 | None | 123 | Supplyng tinned copper lugs and crimping and wiring to terminal point for wire fo 4 sqmm
| Each | 7.0 | 7.0 | 34.0 | False | None | None | False | None | False | 238.0 | 0 |
2979996 | 98809 | None | 124 | Supplyng tinned copper lugs and crimping and wiring to terminal point for wire fo 6 sqmm
| Each | 7.0 | 7.0 | 16.0 | False | None | None | False | None | False | 112.0 | 0 |
2979997 | 98809 | None | 5.19.9 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure 12 Way SP & N
| Each | 2329.0 | 2329.0 | 3.0 | False | None | None | False | None | False | 6987.0 | 0 |
2979998 | 98809 | None | 5.18.1 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP
| Each | 415.0 | 415.0 | 28.0 | False | None | None | False | None | False | 11620.0 | 0 |
2979999 | 98809 | None | 5.18.5 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP
| Each | 1060.0 | 1060.0 | 4.0 | False | None | None | False | None | False | 4240.0 | 0 |
2980000 | 98809 | None | 5.18.9 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPN
| Each | 3088.0 | 3088.0 | 1.0 | False | None | None | False | None | False | 3088.0 | 0 |
2980001 | 98809 | None | 5.20.4 | Supplying, fixing and wiring Residual current circuit breaker (RCCB)
240/450V upto 300mA sensitivity on existing wood/ panel board. 32.40A 2 pole "
| Each | 4559.0 | 4559.0 | 2.0 | False | None | None | False | None | False | 9118.0 | 0 |
2980002 | 98809 | None | 11.3.2 | Supplying of .feet PVC Batten with integrated LED tube . W with high quality diffuser with Life of 25000 burning hours & 70perc lumen maintenance with CRI 80. Power Input: 220 240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4inch 20/22 W
| Each | 690.0 | 690.0 | 58.0 | False | None | None | False | None | False | 40020.0 | 0 |
2980003 | 98809 | None | 131 | Supply & fitting of 12W LED retro fit lamp with holder
| Each | 450.0 | 450.0 | 8.0 | False | None | None | False | None | False | 3600.0 | 0 |
2980004 | 98809 | None | 132 | Supply & fitting of 18W LED Bulk Head light fixture
| Each | 1650.0 | 1650.0 | 5.0 | False | None | None | False | None | False | 8250.0 | 0 |
2980005 | 98809 | None | 11.5.3 | Supply of round/square recess/surface mounted rolling type LED Down light with . W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70perc lumen maintenance with CRI 80. Power Input: 220 240V @50/60Hz & Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15 18W
| Each | 1324.0 | 1324.0 | 12.0 | False | None | None | False | None | False | 15888.0 | 0 |
2980006 | 98809 | None | 6.1 | Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply
| Each | 1492.0 | 1492.0 | 4.0 | False | None | None | False | None | False | 5968.0 | 0 |
2980007 | 98809 | None | 6.4.1 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48" Sweep 5 Star (1200 mm)
| Each | 2677.0 | 2677.0 | 30.0 | False | None | None | False | None | False | 80310.0 | 0 |
2980008 | 98809 | None | 6.5.2 | Supplying wall mounting fan suitable to operate at single- phase 230v AC. supply. 400 mm Sweep
| Each | 3212.0 | 3212.0 | 5.0 | False | None | None | False | None | False | 16060.0 | 0 |
2980009 | 98809 | None | 11.9.1 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with . W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Floodlight 70W
| Each | 6768.0 | 6768.0 | 2.0 | False | None | None | False | None | False | 13536.0 | 0 |
2980010 | 98809 | None | 13.7.1 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps On wall/ ceiling / Rafter / Girders
| Each | 122.0 | 122.0 | 58.0 | False | None | None | False | None | False | 7076.0 | 0 |
2980011 | 98809 | None | 13.10 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.
| Each | 171.0 | 171.0 | 35.0 | False | None | None | False | None | False | 5985.0 | 0 |
2980012 | 98809 | None | 13.13 | Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.
| Each | 707.0 | 707.0 | 4.0 | False | None | None | False | None | False | 2828.0 | 0 |
2980013 | 98809 | None | 14.44 | Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
| Each | 11903.05 | 11903.05 | 8.0 | False | None | None | False | None | False | 95224.4 | 0 |
2980014 | 98809 | None | 142 | Supplying, fixing, testing and commissioning of CP health faucet consisting of 1 No 15 mm dia CP angle cock with wall flange PVC flexible tube of 1.00m long tube with end nuts hand operated spray unirt CP crutch complete directed by the engineer
| Each | 2400.0 | 2400.0 | 8.0 | False | None | None | False | None | False | 19200.0 | 0 |
2980015 | 98809 | None | 14.93 a | Providing and fixing Toilet paper holder made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy
| Each | 889.76 | 889.76 | 8.0 | False | None | None | False | None | False | 7118.08 | 0 |
2980016 | 98809 | None | 144 | Supplying and fixing of double coat hook fixed on the toilet dooe as directed by the enginner
| Each | 750.0 | 750.0 | 8.0 | False | None | None | False | None | False | 6000.0 | 0 |
2980017 | 98809 | None | 14.7.8 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Surgeon type wash basin of size 660x460 mm with
a pair of 15 mm C.P. brass pillar taps with elbow including operated levers
| 8 Mtrs | 4361.84 | 4361.84 | 8.0 | False | None | None | False | None | False | 34894.72 | 0 |
2980018 | 98809 | None | 14.22 a | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer
| No | 859.01 | 859.01 | 8.0 | False | None | None | False | None | False | 6872.08 | 0 |
2980019 | 98809 | None | 14.36.2 | Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 g
| No | 98.63 | 98.63 | 8.0 | False | None | None | False | None | False | 789.04 | 0 |
2980020 | 98809 | None | 13.27.2 | Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour 15 mm nominal bore with 450 mm length
| No | 123.02 | 123.02 | 8.0 | False | None | None | False | None | False | 984.16 | 0 |
2980021 | 98809 | None | 14.53 a | Providing and fixing Angle cock medium with wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy
| Each | 1081.71 | 1081.71 | 8.0 | False | None | None | False | None | False | 8653.68 | 0 |
2980022 | 98809 | None | 14.85 a | Providing and fixing Liquid soap dispenser made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy
| Each | 1851.63 | 1851.63 | 8.0 | False | None | None | False | None | False | 14813.04 | 0 |
2980023 | 98809 | None | 14.39 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 g.
| Each | 206.8 | 206.8 | 8.0 | False | None | None | False | None | False | 1654.4 | 0 |
2980024 | 98809 | None | 13.14 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 g.
| No | 897.18 | 897.18 | 10.0 | False | None | None | False | None | False | 8971.8 | 0 |
2980025 | 98809 | None | 153 | Supplying, fixing, testting and commissioning of portable water cooler in corridors for drinking water with all necessary accessories
| Each | 15000.0 | 15000.0 | 2.0 | False | None | None | False | None | False | 30000.0 | 0 |
2980026 | 98809 | None | 11.3.1 | Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete. Heavy Duty GI pipe of 15mm dia
| m | 243.92 | 243.92 | 15.0 | False | None | None | False | None | False | 3658.8 | 0 |
2980027 | 98809 | None | 11.3.2 | Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete. Heavy Duty GI pipe of 20mm dia
| m | 278.91 | 278.91 | 50.0 | False | None | None | False | None | False | 13945.5 | 0 |
2980028 | 98809 | None | 11.3.3 | Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete. Heavy Duty GI pipe of 25mm dia
| m | 380.72 | 380.72 | 20.0 | False | None | None | False | None | False | 7614.4 | 0 |
2980029 | 98809 | None | 11.3.4 | Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete. Heavy Duty GI pipe of 32mm dia
| m | 453.89 | 453.89 | 50.0 | False | None | None | False | None | False | 22694.5 | 0 |
2980030 | 98809 | None | 11.3.5 | Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete. Heavy Duty GI pipe of 40mm dia
| m | 528.13 | 528.13 | 15.0 | False | None | None | False | None | False | 7921.95 | 0 |
2980031 | 98809 | None | 11.3.6 | Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete. Heavy Duty GI pipe of 50mm dia
| m | 720.08 | 720.08 | 55.0 | False | None | None | False | None | False | 39604.4 | 0 |
2980032 | 98809 | None | 11.3.7 | Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will m ake his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete.Heavy Duty GI pipe of 65mm dia
| m | 884.46 | 884.46 | 55.0 | False | None | None | False | None | False | 48645.3 | 0 |
2980033 | 98809 | None | 11.15.4 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 32 mm dia GM (Copper alloy) Gate valves
| Each | 1418.95 | 1418.95 | 2.0 | False | None | None | False | None | False | 2837.9 | 0 |
2980034 | 98809 | None | 11.15.5 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 40 mm dia GM (Copper alloy) Gate valves
| Each | 1590.75 | 1590.75 | 1.0 | False | None | None | False | None | False | 1590.75 | 0 |
2980035 | 98809 | None | 11.15.6 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 50 mm dia GM (Copper alloy)
| Each | 1790.12 | 1790.12 | 2.0 | False | None | None | False | None | False | 3580.24 | 0 |
2980036 | 98809 | None | 11.15.7 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 65 mm dia GM (Copper alloy
| Each | 1982.07 | 1982.07 | 2.0 | False | None | None | False | None | False | 3964.14 | 0 |
2980037 | 98809 | None | 165 | Supplyig installing testing and commisioning of brass body nickel plated automatic air release valves with brass spindle NBR and joint SS spring polypropylenic float at top most points of water supply distribution ringman Standard make conforming to ISI standards and as per instruction of engineer
| Each | 1650.0 | 1650.0 | 2.0 | False | None | None | False | None | False | 3300.0 | 0 |
2980038 | 98809 | None | 166 | Supplying fixing in position solid block masonry pedals pf approx size 400X230X230 mm with brackets and GI clamps for laying pipes on terrace complete as directed by engineer
| Each | 600.0 | 600.0 | 50.0 | False | None | None | False | None | False | 30000.0 | 0 |
2980039 | 98809 | None | 167 | Providing & fixing brass Y pot stainer screw type tested to 20 kg/sqm 65 mm dia at terrace level
| Each | 5600.0 | 5600.0 | 1.0 | False | None | None | False | None | False | 5600.0 | 0 |
2980040 | 98809 | None | 168 | Supply and fixing of GM ball cock with copper float high pressure of approved brand of manuf and fixed onto inlet pipe at UG sump & OHT
| Each | 1650.0 | 1650.0 | 2.0 | False | None | None | False | None | False | 3300.0 | 0 |
2980041 | 98809 | None | 11.17.5 | Providing GM (copper alloy) wheel valves/ check valve confirming to IS 778/1990 Class-I with latest amendments No. 1 and with ISI mark screwed in bonnet integral seat inside, screw, rising spindle screwed female ends confirming to IS 554/ 1990 body hudraulically tested 1.50 HP seat hydraulically tested 1.00 HP etc. complete.
| No | 1206.85 | 1206.85 | 1.0 | False | None | None | False | None | False | 1206.85 | 0 |
2980042 | 98809 | None | 170 | Supplying Laying jointing testing and Commissioning of PVC pipes 6 kg/cm2 waste pipe of agri series conforming to IS 4985 incld all fittings like tees elbows bends collars coupling jointing etc with solvent cement followed by application of leak proof adhesive like FRP paste laid on floors inside the toilets to reqd slope incld making necessary boes in walls/ foundation / concrete slab as applicable making good the bores with CM 1:3 or CC as applicable curing etc as directed by enginner 40 mm dia
| m | 220.0 | 220.0 | 20.0 | False | None | None | False | None | False | 4400.0 | 0 |
2980043 | 98809 | None | 10.1.5 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc PVC pipes 75mm dia., 6 kg/sqcm & c
| m | 233.31 | 233.31 | 50.0 | False | None | None | False | None | False | 11665.5 | 0 |
2980044 | 98809 | None | 10.1.7 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. PVC pipes 110mm dia., 6 kg/cm2
| m | 435.87 | 435.87 | 50.0 | False | None | None | False | None | False | 21793.5 | 0 |
2980045 | 98809 | None | 173 | Providing fixing testing and commissioning of deep seal PVC multi inlet floor trap of self cleaning design moulded or fabricated with CP grating, rubber ring/solvent cement followed by application of leak proof adhesive like FRP paste incld making good floors etc complete as directed by the enginner standard make conforming to ISI standard model as per attched phot catalogue and as per direction of enginner 110mm dia inlet 75mm dia outlet
| Each | 800.0 | 800.0 | 12.0 | False | None | None | False | None | False | 9600.0 | 0 |
2980046 | 98809 | None | 174 | MS sheet metal brackets the length of the bracket shall be equal to the sum of the outer dia of all pipe and 50mm for working space per pipe of size 75 mm and 100 mm for working space per pipe size of 75mm and above
| Kg | 140.0 | 140.0 | 30.0 | False | None | None | False | None | False | 4200.0 | 0 |
2980047 | 98809 | None | 10.1.7 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest
amendments and conveying to worksite, rolling and lowering into
trenches, laying true to line and level and perfect linking at joints, testing
and commissioning, including loading unloading at both destinations
and cuts of pipes wherever necessary including jointing of PVC pipes
and specials (excluding cost of specials) with jointing of approved
type, with all labour with all lead & lift including encasing the pipe
alround to a depth of not less than 15 cms. with soft gravel or selected
earth available from the excavation etc. complete and giving necessary
hydraulic test to the required pressure as per ISS (Contractor will make
his own arrangements for procuring water for testing) etc. PVC pipes 110mm dia., 6 kg/sqcm
| m | 435.87 | 435.87 | 10.0 | False | None | None | False | None | False | 4358.7 | 0 |
2980048 | 98809 | None | 10.1.9 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. PVC pipes 160mm dia 6kg/sqcm
| m | 655.39 | 655.39 | 80.0 | False | None | None | False | None | False | 52431.2 | 0 |
2980049 | 98809 | None | 177 | Providing fixing testing and commissioning of PVC rain water head dome type grating with puddle flange to fix head in RCC slab specifically fabricated from min 4mm thick PVC sheet incld removable heavy dutty PVC grating 50X3mm thick PVC flats as per approved design The quoted rate shall include for necessary grouting the khurras base with approved sealent complete as shown in drawing & specified Std make conforming to ISI Standards model as per attached photo catalogue & as per directio of enginner 150X150 mmm PVC grating
| No | 1800.0 | 1800.0 | 8.0 | False | None | None | False | None | False | 14400.0 | 0 |
2980050 | 98809 | None | 13.40.3 | Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. 3 HP, size 50x40 Head 30M, Discharge 198 LPM
| No | 19756.8 | 19756.8 | 2.0 | False | None | None | False | None | False | 39513.6 | 0 |
2980051 | 98809 | None | 179 | Supply Installation testing & commissioning of 4 Mp IP indoor dome camera with 1/3@ progressive scan CMOS image sensor 2.8mm fixed lens 2560X1440 " 30fps resolution IR illumination upto 40m IR distance WDR video compression H 265+/H264+/H264/ DC 12V Poe IP67 ingress protection IK10 Vandal resistance The prices should include the necessary mounts & brackets
| No | 15000.0 | 15000.0 | 11.0 | False | None | None | False | None | False | 165000.0 | 0 |
2980052 | 98809 | None | 180 | Supply Installation testing & commissioning of 5 Mp IP indoor dome camera with 1/3@ progressive scan CMOS image sensor F1.5 lens2688X1520 resolution 0.005 lux/F1.6 0 LUX/ F1.6 IR illumination upto 60m IR distance built-in micro SD/SDHC/SDXC card slot upto 128 gb inbuilt 64 gb micri sd card DC12V Poe IP ingress protection IK10 Vanidal resistance The prices should include the necessary mounts & brackets
| No | 20000.0 | 20000.0 | 2.0 | False | None | None | False | None | False | 40000.0 | 0 |
2980053 | 98809 | None | 181 | Supply Installation & commissioning of 16 channel NVR 16 channels input 1 audio output 1HDMI 1VGA display split 1/3/8/9/16 h265/H264/MJPEG/MPEG4 resolution should support upto 8MP backup compatability USB drive 1 RJ 45 port 2 SATA ports upto 16TB Power supply single 100240 VAC 50/60 Hz
| No | 25000.0 | 25000.0 | 2.0 | False | None | None | False | None | False | 50000.0 | 0 |
2980054 | 98809 | None | 182 | 4TB HDD
| No | 15000.0 | 15000.0 | 2.0 | False | None | None | False | None | False | 30000.0 | 0 |
2980055 | 98809 | None | 183 | 16 X 100/1000 GbE base T 802.3 at supported PoE + ports + 4 x 1GbE SFP ports mangaged switch with layer 2+ image 50degree operating temp support
| No | 25000.0 | 25000.0 | 2.0 | False | None | None | False | None | False | 50000.0 | 0 |
2980056 | 98809 | None | 8.12.5 | Supplying & Fixing of Patch panel for LAN cabling 24 Port 10/100/1000 patch panel
| No | 7900.0 | 7900.0 | 2.0 | False | None | None | False | None | False | 15800.0 | 0 |
2980057 | 98809 | None | 8.11.2 | Supplying & Fixing of . ms Cat 6 Patch Cable 2 m
| No | 257.0 | 257.0 | 14.0 | False | None | None | False | None | False | 3598.0 | 0 |
2980058 | 98809 | None | 186 | RJ 45 connector with crimping with 4x4 PVC boxes
| Set | 163.0 | 163.0 | 10.0 | False | None | None | False | None | False | 1630.0 | 0 |
2980059 | 98809 | None | 8.4.5 | Supplying & Fixing of switch mounting rack with power manager & Cable manager. 18U with 650mm depth
| No | 28396.0 | 28396.0 | 1.0 | False | None | None | False | None | False | 28396.0 | 0 |
2980060 | 98809 | None | 8.4.2 | Supplying & Fixing of switch mounting rack with power manager & Cable manager. 6U with 450mm depth
| No | 6977.0 | 6977.0 | 1.0 | False | None | None | False | None | False | 6977.0 | 0 |
2980061 | 98809 | None | 8.5 | Supplying & Fixing of Power strip
| No | 1457.0 | 1457.0 | 2.0 | False | None | None | False | None | False | 2914.0 | 0 |
2980062 | 98809 | None | 8.6 | Supplying of shelf
| No | 827.0 | 827.0 | 4.0 | False | None | None | False | None | False | 3308.0 | 0 |
2980063 | 98809 | None | 8.8 | Supplying & Fixing of Fan
| No | 1209.0 | 1209.0 | 2.0 | False | None | None | False | None | False | 2418.0 | 0 |
2980064 | 98809 | None | 1.2.2 | Supplying heavy gauge PVC conduit pipe . mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25 mm dia 2 mm thick
| m | 78.0 | 78.0 | 350.0 | False | None | None | False | None | False | 27300.0 | 0 |
2980065 | 98809 | None | 8.1 | Supplying and drawing UTP-CAT 6E LAN cable.
| m | 38.0 | 38.0 | 610.0 | False | None | None | False | None | False | 23180.0 | 0 |
2980066 | 98809 | None | 194 | Supplying & fixing of 42@ HD TV with HDMI cable & accessories
| Each | 55000.0 | 55000.0 | 1.0 | False | None | None | False | None | False | 55000.0 | 0 |
2980067 | 98809 | None | 17.3.3 | Supply & installation of 6W RMS wall mount speaker with power taps at 6/4/2 on 100V 60-15000 Hz with accessories
| No | 1793.0 | 1793.0 | 11.0 | False | None | None | False | None | False | 19723.0 | 0 |
2980068 | 98809 | None | 17.3.1 | Supply installation testing & commissioning of 6 zone voice alarm controller with USB Mp3 player with seamless integration facility with fire alarm panel for voice evacuation complete as reqd
| No | 126411.0 | 126411.0 | 1.0 | False | None | None | False | None | False | 126411.0 | 0 |
2980069 | 98809 | None | 197 | Supply & installation of 240 W mixing amplifier
| No | 45001.0 | 45001.0 | 1.0 | False | None | None | False | None | False | 45001.0 | 0 |
2980070 | 98809 | None | 198 | Supplying installation testing & commissioning of voice command keypad 6 zone with microphone assembly complete as
| No | 81756.0 | 81756.0 | 1.0 | False | None | None | False | None | False | 81756.0 | 0 |
2980071 | 98809 | None | 199 | Supply & installation of 2C x 1.5 sqm
| m | 54.0 | 54.0 | 410.0 | False | None | None | False | None | False | 22140.0 | 0 |
2980072 | 98809 | None | 1.2.2 | Supplying heavy gauge PVC conduit pipe . mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25 mm dia 2 mm thick
| m | 78.0 | 78.0 | 215.0 | False | None | None | False | None | False | 16770.0 | 0 |
2980073 | 98809 | None | 8.4.3 | Supplying & Fixing of switch mounting rack with power manager & Cable manager. 9U with 450mm depth
| No | 8476.0 | 8476.0 | 1.0 | False | None | None | False | None | False | 8476.0 | 0 |
2980074 | 98809 | None | 8.5 | Supplying & Fixing of Power strip
| No | 1457.0 | 1457.0 | 1.0 | False | None | None | False | None | False | 1457.0 | 0 |
2980075 | 98809 | None | 8.6 | Supplying of shelf
| No | 827.0 | 827.0 | 1.0 | False | None | None | False | None | False | 827.0 | 0 |
2980076 | 98809 | None | 204 | Connecting cables with accessories
| No | 5000.0 | 5000.0 | 1.0 | False | None | None | False | None | False | 5000.0 | 0 |
2980077 | 98809 | None | 8.1 | Supplying and drawing UTP-CAT 6E LAN cable.
| m | 38.0 | 38.0 | 560.0 | False | None | None | False | None | False | 21280.0 | 0 |
2980078 | 98809 | None | 8.2.2 | Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. 2Pair
| m | 21.0 | 21.0 | 60.0 | False | None | None | False | None | False | 1260.0 | 0 |
2980079 | 98809 | None | 8.9.12 | Supplying fixing of Network Switches 8 port 10/100/1000 Switch
| Each | 3100.0 | 3100.0 | 1.0 | False | None | None | False | None | False | 3100.0 | 0 |
2980080 | 98809 | None | 8.10.1 | Supplying & fixing of I/O socket with back box Single I/O
| Each | 490.0 | 490.0 | 12.0 | False | None | None | False | None | False | 5880.0 | 0 |
2980081 | 98809 | None | 8.11.2 | Supplying & Fixing of . ms Cat 6 Patch Cable 2 m
| Each | 257.0 | 257.0 | 12.0 | False | None | None | False | None | False | 3084.0 | 0 |
2980082 | 98809 | None | 8.11.3 | Supplying & Fixing of . ms Cat 6 Patch Cable 3 m
| Each | 331.0 | 331.0 | 12.0 | False | None | None | False | None | False | 3972.0 | 0 |
2980083 | 98809 | None | 8.12.5 | Supplying & Fixing of Patch panel for LAN cabling 24 Port 10/100/1000 patch panel
| Each | 7900.0 | 7900.0 | 1.0 | False | None | None | False | None | False | 7900.0 | 0 |
2980084 | 98809 | None | 3.6.11 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone Socket
| Each | 156.0 | 156.0 | 2.0 | False | None | None | False | None | False | 312.0 | 0 |
2980085 | 98809 | None | 8.3 | Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6.
| m | 44.0 | 44.0 | 150.0 | False | None | None | False | None | False | 6600.0 | 0 |
2980086 | 98809 | None | 8.13.1 | Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination 10 Pair
| m | 345.0 | 345.0 | 1.0 | False | None | None | False | None | False | 345.0 | 0 |
2980087 | 98809 | None | 1.2.2 | Supplying heavy gauge PVC conduit pipe . mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25 mm dia 2 mm thick
| m | 78.0 | 78.0 | 450.0 | False | None | None | False | None | False | 35100.0 | 0 |
2980088 | 98809 | None | 216 | Supply & fixing of GbE speed WiFI router, PoE support
| Each | 10000.0 | 10000.0 | 1.0 | False | None | None | False | None | False | 10000.0 | 0 |
2980089 | 98809 | None | 217 | Providing and removing centering shuttering struttring propping etc and removal of form work for columns pillars post and struts square rectangular polygon in plan incld cost of all materials labour complete as per specs Columns 70 percent of qty Second Floor
| Sqm | 5130.2 | 5130.2 | 43.3 | False | None | None | False | None | False | 222137.66 | 0 |
2980090 | 98809 | None | 218 | Providing and removing centering shuttering struttring propping etc and removal of form work for columns pillars post and struts square rectangular polygon in plan incld cost of all materials labour complete as per specs Columns 70 percent of qty Terrace Floor
| Sqm | 5180.49 | 5180.49 | 8.08 | False | None | None | False | None | False | 41858.3592 | 0 |
2980091 | 98809 | None | 219 | Providing and removing centering shuttering struttring propping etc and removal of form work for columns pillars post and struts square rectangular polygon in plan incld cost of all materials labour complete as per specs Retaining structure 10 percent of concrete qty GF
| Sqm | 718.52 | 718.52 | 6.48 | False | None | None | False | None | False | 4656.0096 | 0 |
2980092 | 98809 | None | 220 | Providing and removing centering shuttering struttring propping etc and removal of form work for columns pillars post and struts square rectangular polygon in plan incld cost of all materials labour complete as per specs Beam and lintel 60 percent of CCqty Second Floor
| Sqm | 4397.31 | 4397.31 | 74.07 | False | None | None | False | None | False | 325708.7517 | 0 |
2980093 | 98809 | None | 221 | Providing and removing centering shuttering struttring propping etc and removal of form work for columns pillars post and struts square rectangular polygon in plan incld cost of all materials labour complete as per specs Beam and lintel 60 percent of CCqty TerraceFloor
| Sqm | 4440.42 | 4440.42 | 13.31 | False | None | None | False | None | False | 59101.9902 | 0 |
2980094 | 98809 | None | 222 | Providing and removing centering shuttering struttring propping etc and removal of form work for columns pillars post and struts square rectangular polygon in plan incld cost of all materials labour complete as per specs Roof 50 percent of CC qty Second Floor
| Sqm | 3664.43 | 3664.43 | 182.05 | False | None | None | False | None | False | 667109.4815 | 0 |
2980095 | 98809 | None | 223 | Providing and removing centering shuttering struttring propping etc and removal of form work for columns pillars post and struts square rectangular polygon in plan incld cost of all materials labour complete as per specs Roof 50 percent of CC qtyTerrace Floor
| Sqm | 3700.35 | 3700.35 | 25.98 | False | None | None | False | None | False | 96135.093 | 0 |
2980096 | 98809 | None | 224 | Providing and removing centering shuttering struttring propping etc and removal of form work for columns pillars post and struts square rectangular polygon in plan incld cost of all materials labour complete as per specs Beam and lintel 60 percent of CCqt Second Floor
| Sqm | 4397.31 | 4397.31 | 23.92 | False | None | None | False | None | False | 105183.6552 | 0 |
2980097 | 98809 | None | 225 | Providing and removing centering shuttering struttring propping etc and removal of form work for columns pillars post and struts square rectangular polygon in plan incld cost of all materials labour complete as per specs Beam and lintel 60 percent of CCqt Terrace Floor
| Sqm | 4440.42 | 4440.42 | 4.64 | False | None | None | False | None | False | 20603.5488 | 0 |
2980098 | 98809 | None | 226 | Providing and removing centering shuttering struttring propping etc and removal of form work for columns pillars post and struts square rectangular polygon in plan incld cost of all materials labour complete as per specs 50 percent of CC qty
| Sqm | 3664.43 | 3664.43 | 9.97 | False | None | None | False | None | False | 36534.3671 | 0 |
2980099 | 98809 | None | 227 | Providing and removing centering shuttering struttring propping etc and removal of form work for columns pillars post and struts square rectangular polygon in plan incld cost of all materials labour complete as per specs Chejjas other projections 45 percent Second Floor
| Sqm | 3195.33 | 3195.33 | 1.68 | False | None | None | False | None | False | 5368.1544 | 0 |
2980100 | 98809 | None | 228 | Providing and removing centering shuttering struttring propping etc and removal of form work for columns pillars post and struts square rectangular polygon in plan incld cost of all materials labour complete as per specs Chejjas other projections 45 percent Terrace Floor
| Sqm | 3226.66 | 3226.66 | 0.46 | False | None | None | False | None | False | 1484.2636 | 0 |
2980101 | 98809 | None | 229 | Supplying fitting and placing TMT FE 550/550D steel reinfocement incld cost of all materials machinery labour cleaning straightnening cutting bending hooking laping welding joints ttying with bnding wire /soft annealed steel wire and other ancilary operations complete as per directions Second Floor
| m | 95808.45 | 95808.45 | 45.44 | False | None | None | False | None | False | 4353535.968 | 0 |
2980102 | 98809 | None | 230 | Supplying fitting and placing TMT FE 550/550D steel reinfocement incld cost of all materials machinery labour cleaning straightnening cutting bending hooking laping welding joints ttying with bnding wire /soft annealed steel wire and other ancilary operations complete as per directions Terrace Floor
| m | 96747.75 | 96747.75 | 8.65 | False | None | None | False | None | False | 836868.0375 | 0 |
2980103 | 98809 | None | 231 | 448 Honne Wood Beading 20X20 mm Seconfd Floor
| m | 58.91 | 58.91 | 75.6 | False | None | None | False | None | False | 4453.596 | 0 |
2980104 | 98809 | None | 232 | 449 Honne Wood Beading 20X20 mm Terrace Floor
| m | 59.48 | 59.48 | 24.0 | False | None | None | False | None | False | 1427.52 | 0 |
2980105 | 98809 | None | 233 | Alluiminium Expansion joints consists of Al base frame thickness 2mm extruded and anodised al plate of 4 mm thickness widht 125 mm 150 mm for 200mm 250mm and 300mm with al profile centering bar and pvc water barrier
| m | 7920.0 | 7920.0 | 55.6 | False | None | None | False | None | False | 440352.0 | 0 |
2980106 | 98809 | None | 234 | Alluiminium Expansion joints consists of Al base frame thickness 2mm extruded and anodised al plate of 4 mm thickness widht 125 mm 150 mm for 200mm 250mm and 300mm with al profile centering bar and pvc water barrier
| m | 7920.0 | 7920.0 | 34.8 | False | None | None | False | None | False | 275616.0 | 0 |
2980107 | 98809 | None | 232 | Providing full nosing for 20mm thick granite slab using required machinery
including cost and conveyance of all materials, labour for all items of work,
HOM of equipment etc., complete as per specification | m | 180.0 | 180.0 | 332.26 | False | None | None | False | None | False | 59806.8 | 0 |