createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1715757199225
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyRESERVED
invitingStrategyTextReserved
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd20000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose23-05-2024 16:30:00
tenderQueryClose23-05-2024 11:00:00
technicalBidOpen24-05-2024 16:35:00
publishedDate16-05-2024 11:38:03
publishedByPostDMA_EE1_CC_KLB
publishedByUserKPE11288 - SHIVANAGOUDA S PATIL
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonSHIVANANGOUDA S PATIL
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9448140095
tenderSupplierListNone
tenderSchedule
createdTs1715757199263
version4
createdDateNone
modifiedDateNone
tenderNumberDMA/2023-24/OW/WORK_INDENT17611
titleConstruction of UGD from Jagat Area Sri Basavaraj Chappade House to Sharanu Avntigi house W No 34 in Kalaburagi City. SFC UNTED 2023-24 (ST)
descriptionConstruction of UGD from Jagat Area Sri Basavaraj Chappade House to Sharanu Avntigi house W No 34 in Kalaburagi City. SFC UNTED 2023-24 (ST)
categoryWORKS
categoryTextWorks
ecv1344492.72
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2161
locationNameDMA City Corporation Kalaburagi
provisionalAmount1600000.0
groupOverheadTotalNone
fileNumberKMP/TS-01/EE/177/SFCSCP/2023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17157571990000NoneNoneOther WorksConstruction of UGD from Jagat Area Sri Basavaraj Chappade House to Sharanu Avntigi house W No 34 in Kalaburagi City. SFC UNTED 2023-24 (ST)1344492.72
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3137461107825None2.1.9Dismantling of Cement Concrete Pavement Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 m3 in volume and stock piling at designated locations and disposal of dismantled materials and stacking serviceable and unserviceablematerials separately ( KPWD Volume-III SR, 2023-24, Item No. 2.19, P. No. 12)Cum591.15591.1543.68FalseNoneNoneFalseNoneFalse25821.4320
3137462107825None1.4.1Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.( KPWD Volume-I SR, 2023-24, Item No. 1.4.1, P. No.5)Cum266.81266.8115.49FalseNoneNoneFalseNoneFalse4132.88690
3137463107825None1.6.1Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances requiredto complete the work. In all kinds of soils. Depth upto 1.50m ( KPWD Volume-I SR, 2023-24, Item No. 1.6.1, P. No. 6).Cum343.88343.88546.0FalseNoneNoneFalseNoneFalse187758.480
3137464107825None10.2.10Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013with latest amendments ended with integral sockets with ISI mark andconveying to worksite, rolling and lowering into trenches, laying true toline and level and perfect linking at joints, testing and commissioning,including loading and unloading at both destinations and cuts of pipeswherever necessary including jointing of UPVC pipes (with cost ofelastomeric sealing rings) and specials (excluding cost of specials) withjointing of approved type, with all labour, lead & lifts, including encasingthe pipes alround to a depth of not less than 15 cms. with soft gravelor selected earth available from the excavation etc. complete and givingnecessary hydraulic test to the required pressure as per ISS (contractorwill make his own arrangements for procuring water for testing) etc.complete for: Pipes of SN 8, 160mm dia. ( KPWD Volume-V SR, 2023-24, Item No.10.2.10, P. No. 114 )m731.85731.8593.0FalseNoneNoneFalseNoneFalse68062.050
3137465107825None10.2.12Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013with latest amendments ended with integral sockets with ISI mark andconveying to worksite, rolling and lowering into trenches, laying true toline and level and perfect linking at joints, testing and commissioning,including loading and unloading at both destinations and cuts of pipeswherever necessary including jointing of UPVC pipes (with cost ofelastomeric sealing rings) and specials (excluding cost of specials) withjointing of approved type, with all labour, lead & lifts, including encasingthe pipes alround to a depth of not less than 15 cms. with soft gravelor selected earth available from the excavation etc. complete and givingnecessary hydraulic test to the required pressure as per ISS (contractorwill make his own arrangements for procuring water for testing) etc.complete for: Pipes of SN 8, 250MM ( KPWD Volume-V SR, 2023-24, Item No.10.2.12, P. No. 114)m1618.051618.05180.0FalseNoneNoneFalseNoneFalse291249.00
3137466107825None16.46.1Providing and constructing of Machinehole chambers conical in shape at top with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15m alround the chamber and brick masonry in C.M 1:4 plaster with bricks of approved quality and CM plaster 1:3 proportion 12mm thick inside and outside except for the conical surface outside where the thickness of plaster shall be 20 mm thick, with 1 to 6 slope in the concrete towards the central drain, finished smooth and fixing of pipes in CC 1:2:4 with graded metal of 20 mm and down size including Providing and fixing SFRC Machinehole frame and cover confoming to IS 12592(Part-I): 1988 & IS 12592(Part-II) :1991 with latest amendments in CC 1:2:4, Providing and fixing of plastic foot steps staggered at 30cms apart as directed, watering, curing,barricading, danger lighting, pouring tar over M.H. frame and cover, cost of tar, shoring, strutting, dewatering, engraving Machinehole No. on the inner and outer conical surface etc. as per the drawing with all lead and lift for various diameters and depths noted below. Constructing Table Moulded Bricks Machinehole 1.2 m internal dia., 1.0 m depth & Heavy duty SFRC cover & frame ( KPWD Volume-V SR, 2023-24, Item No. 16.46.1 , P. No. 204No26248.9526248.951.0FalseNoneNoneFalseNoneFalse26248.950
3137467107825None16.46.2Providing and constructing of Machinehole chambers conical in shape at top with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15m alround the chamber and brick masonry in C.M 1:4 plaster with bricks of approved quality and CM plaster 1:3 proportion 12mm thick inside and outside except for the conical surface outside where the thickness of plaster shall be 20 mm thick, with 1 to 6 slope in the concrete towards the central drain, finished smooth and fixing of pipes in CC 1:2:4 with graded metal of 20 mm and down size including Providing and fixing SFRC Machinehole frame and cover confoming to IS 12592(Part-I): 1988 & IS 12592(Part-II) :1991 with latest amendments in CC 1:2:4, Providing and fixing of plastic foot steps staggered at 30cms apart as directed, watering, curing,barricading, danger lighting, pouring tar over M.H. frame and cover, cost of tar, shoring, strutting, dewatering, engraving Machinehole No. on the inner and outer conical surface etc. as per the drawing with all lead and lift for various diameters and depths noted below. Constructing Table Moulded Bricks Machinehole 1.2 m internal dia., 1.40 m depth & Heavy duty SFRC cover & frame ( KPWD Volume-V SR, 2023-24, Item No. 16.46.2 , P. No. 204)No35534.135534.11.0FalseNoneNoneFalseNoneFalse35534.10
3137468107825None16.46.2Providing and constructing of Machinehole chambers conical in shape at top with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15m alround the chamber and brick masonry in C.M 1:4 plaster with bricks of approved quality and CM plaster 1:3 proportion 12mm thick inside and outside except for the conical surface outside where the thickness of plaster shall be 20 mm thick, with 1 to 6 slope in the concrete towards the central drain, finished smooth and fixing of pipes in CC 1:2:4 with graded metal of 20 mm and down size including Providing and fixing SFRC Machinehole frame and cover confoming to IS 12592(Part-I): 1988 & IS 12592(Part-II) :1991 with latest amendments in CC 1:2:4, Providing and fixing of plastic foot steps staggered at 30cms apart as directed, watering, curing,barricading, danger lighting, pouring tar over M.H. frame and cover, cost of tar, shoring, strutting, dewatering, engraving Machinehole No. on the inner and outer conical surface etc. as per the drawing with all lead and lift for various diameters and depths noted below. Constructing Table Moulded Bricks Machinehole 1.2 m internal dia., 1.6 m depth & Heavy duty SFRC cover & frame ( KPWD Volume-V SR, 2023-24, Item No. 16.46.2 , P. No. 204)No40176.1540176.153.0FalseNoneNoneFalseNoneFalse120528.450
3137469107825None16.46.2Providing and constructing of Machinehole chambers conical in shape at top with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15m alround the chamber and brick masonry in C.M 1:4 plaster with bricks of approved quality and CM plaster 1:3 proportion 12mm thick inside and outside except for the conical surface outside where the thickness of plaster shall be 20 mm thick, with 1 to 6 slope in the concrete towards the central drain, finished smooth and fixing of pipes in CC 1:2:4 with graded metal of 20 mm and down size including Providing and fixing SFRC Machinehole frame and cover confoming to IS 12592(Part-I): 1988 & IS 12592(Part-II) :1991 with latest amendments in CC 1:2:4, Providing and fixing of plastic foot steps staggered at 30cms apart as directed, watering, curing,barricading, danger lighting, pouring tar over M.H. frame and cover, cost of tar, shoring, strutting, dewatering, engraving Machinehole No. on the inner and outer conical surface etc. as per the drawing with all lead and lift for various diameters and depths noted below. Constructing Table Moulded Bricks Machinehole 1.2 m internal dia., 1.80 m depth & Heavy duty SFRC cover & frame ( KPWD Volume-V SR, 2023-24, Item No. 16.46.2 , P. No. 204)No44819.2544819.253.0FalseNoneNoneFalseNoneFalse134457.750
3137470107825None16.46.2Providing and constructing of Machinehole chambers conical in shape at top with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15m alround the chamber and brick masonry in C.M 1:4 plaster with bricks of approved quality and CM plaster 1:3 proportion 12mm thick inside and outside except for the conical surface outside where the thickness of plaster shall be 20 mm thick, with 1 to 6 slope in the concrete towards the central drain, finished smooth and fixing of pipes in CC 1:2:4 with graded metal of 20 mm and down size including Providing and fixing SFRC Machinehole frame and cover confoming to IS 12592(Part-I): 1988 & IS 12592(Part-II) :1991 with latest amendments in CC 1:2:4, Providing and fixing of plastic foot steps staggered at 30cms apart as directed, watering, curing,barricading, danger lighting, pouring tar over M.H. frame and cover, cost of tar, shoring, strutting, dewatering, engraving Machinehole No. on the inner and outer conical surface etc. as per the drawing with all lead and lift for various diameters and depths noted below. Constructing Table Moulded Bricks Machinehole 1.2 m internal dia., 2.0 m depth & Heavy duty SFRC cover & frame ( KPWD Volume-V SR, 2023-24, Item No. 16.46.2 , P. No. 204)No49461.349461.31.0FalseNoneNoneFalseNoneFalse49461.30
3137471107825None3.7Compacting Original Ground Loosening, leveling and Compacting original ground supportingembankment to facilitate placement of first layer of embankment,scarified to a depth of 150 mm, mixed with water at OMC and thencompacted by rolling so as to achieve minimum dry density asgiven in Table 300-2 for embankment construction (KPWD Volume-III SR 2023-24, Item No. 3.7, P. No.17)Cum110.25110.2527.3FalseNoneNoneFalseNoneFalse3009.8250
3137472107825None3.6Construction of Subgrade and Earthen Shoulders Construction of sub-grade and earthen shoulders with approvedmaterial obtained from borrow pits with all lifts & leads,transporting to site, spreading, grading to required slope andcompacted to meet requirement of table No. 300-2 (KPWD Volume-III SR 2023-24, Item No. 3.6, P. No.17)Cum517.65517.6527.3FalseNoneNoneFalseNoneFalse14131.8450
3137473107825None4.7Wet Mix Macadam (Plant Mix Method) Providing, laying, spreading and compacting graded stoneaggregate to wet mix macadam specification including premixingthe Material with water at OMC in mechanical mix plant carriageof mixed Material by tipper to site, laying in uniform layers withpaver/grader in sub-base / base course on well prepared surfaceand compacting with vibratory roller to achieve the desired density.(KPWD Volume-III SR 2023-24, Item No. 4.7, P. No.26)Cum2686.952686.9540.95FalseNoneNoneFalseNoneFalse110030.60250
3137474107825None16.27Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M20 (Grade), coarse and fine aggregates conforming to IS:383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, , primer, sealant , curing of concrete slabs for 14-days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work (KPWD Volume-III SR 2023-24, Item No. 16.27, P. No.149)Cum6692.76692.740.95FalseNoneNoneFalseNoneFalse274066.0650
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17157572000000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17157572000000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17157572000000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17157572000000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17157572000000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17157576920000NoneNoneELIGIBILITYTerms and conditions as per bid DocumentsNone
17157577800000NoneNoneELIGIBILITYNote: All subsequent corrigendum/amendment shall be published only on website and not in press. Hence tenderers are advised to always be in touch with our said website until the tender is finally opened.None
17158375990000NoneNoneELIGIBILITYTerms and conditions as per bid DocumentsNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneSatisfactorily completed as prime contractor, at least any work to a extent of Rs. 4.00 Lakhs i.e., ANY CIVIL DEVELOPMENT WORK (25% for SC & ST category) of the cost of the work.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNonefor SC/ST category: - Assessed available tender capacity (AXNX5.00 B)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- BID CAPACITY LETTER
NoneNoneNoneNoneTender bid capacity The bidder should upload the ongoing works in handCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- BID CAPACITY LETTER
NoneNoneNoneNoneAchieved in at least two (for other category) and one (for SC & ST) financial years a minimum annual financial turnover Civil works only of Rs. 16.00 Lakhs (usually not less than estimated cost under this contractFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneKPWD Registration civil licenseOthersKPWD Registration civil license
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneAS PER TENDER DOCUMENTOthersAS PER TENDER DOCUMENT
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- AS PER TENDER DOCUMENT
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
KPWD Registration CertificateTrueTechnical Bid
Reserved Category Certificate STTrueTechnical Bid
WORK DONE CertificateTrueTechnical Bid
AS PER BID DOCUMENTTrueTechnical Bid
BID CAPACITY LETTERTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone