1716484811000 | 0 | None | None | Buildings | Construction of 4Class Romms at 14th Ward in Sandur Town in Ballari Dist. (3 Class Rooms) | 4062378.82 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3151096 | 108608 | None | CODE01 | Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-charge. | Cum | 1746.15 | 1746.15 | 17.12 | False | None | None | False | None | False | 29894.088 | 0 | 3151097 | 108608 | None | CODE02 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 107.1 | 107.1 | 90.09 | False | None | None | False | None | False | 9648.639 | 0 | 3151098 | 108608 | None | CODE03 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 123.9 | 123.9 | 165.6 | False | None | None | False | None | False | 20517.84 | 0 | 3151099 | 108608 | None | CODE04 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6288.45 | 6288.45 | 24.25 | False | None | None | False | None | False | 152494.9125 | 0 | 3151100 | 108608 | None | CODE05 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7170.28 | 7170.28 | 15.55 | False | None | None | False | None | False | 111497.854 | 0 | 3151101 | 108608 | None | CODE06 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11286.56 | 11286.56 | 2.46 | False | None | None | False | None | False | 27764.9376 | 0 | 3151102 | 108608 | None | CODE07 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5891.55 | 5891.55 | 24.0 | False | None | None | False | None | False | 141397.2 | 0 | 3151103 | 108608 | None | CODE08 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 17.49 | False | None | None | False | None | False | 117330.7905 | 0 | 3151104 | 108608 | None | CODE09 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 9958.73 | 9958.73 | 7.09 | False | None | None | False | None | False | 70607.3957 | 0 | 3151105 | 108608 | None | CODE10 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11286.56 | 11286.56 | 4.52 | False | None | None | False | None | False | 51015.2512 | 0 | 3151106 | 108608 | None | CODE11 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 279.3 | 279.3 | 61.3 | False | None | None | False | None | False | 17121.09 | 0 | 3151107 | 108608 | None | CODE12 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 497.7 | 497.7 | 52.81 | False | None | None | False | None | False | 26283.537 | 0 | 3151108 | 108608 | None | CODE13 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8367.45 | 8367.45 | 33.59 | False | None | None | False | None | False | 281062.6455 | 0 | 3151109 | 108608 | None | CODE14 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6555.15 | 6555.15 | 0.94 | False | None | None | False | None | False | 6161.841 | 0 | 3151110 | 108608 | None | CODE15 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11138.4 | 11138.4 | 13.68 | False | None | None | False | None | False | 152373.312 | 0 | 3151111 | 108608 | None | CODE16 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10094.18 | 10094.18 | 0.48 | False | None | None | False | None | False | 4845.2064 | 0 | 3151112 | 108608 | None | CODE17 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10442.25 | 10442.25 | 24.74 | False | None | None | False | None | False | 258341.265 | 0 | 3151113 | 108608 | None | CODE18 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. for building | Tonne | 94510.5 | 94510.5 | 6.21 | False | None | None | False | None | False | 586910.205 | 0 | 3151114 | 108608 | None | CODE19 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 4701.9 | 4701.9 | 19.62 | False | None | None | False | None | False | 92251.278 | 0 | 3151115 | 108608 | None | CODE20 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer- in-Charge. | Kgs | 144.9 | 144.9 | 136.08 | False | None | None | False | None | False | 19717.992 | 0 | 3151116 | 108608 | None | CODE21 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement: 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 221.55 | 221.55 | 184.14 | False | None | None | False | None | False | 40796.217 | 0 | 3151117 | 108608 | None | CODE22 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 267.75 | 267.75 | 162.14 | False | None | None | False | None | False | 43412.985 | 0 | 3151118 | 108608 | None | CODE23 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 366.45 | 366.45 | 246.08 | False | None | None | False | None | False | 90176.016 | 0 | 3151119 | 108608 | None | CODE24 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 105.0 | 105.0 | 286.07 | False | None | None | False | None | False | 30037.35 | 0 | 3151120 | 108608 | None | CODE25 | Flooring with 25mm thick polished shahabad slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. | Sqm | 1717.8 | 1717.8 | 168.37 | False | None | None | False | None | False | 289225.986 | 0 | 3151121 | 108608 | None | CODE26 | Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. | Sqm | 1461.6 | 1461.6 | 27.9 | False | None | None | False | None | False | 40778.64 | 0 | 3151122 | 108608 | None | CODE27 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 133.35 | 133.35 | 346.28 | False | None | None | False | None | False | 46176.438 | 0 | 3151123 | 108608 | None | CODE28 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 182.7 | 182.7 | 259.99 | False | None | None | False | None | False | 47500.173 | 0 | 3151124 | 108608 | None | CODE29 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 120.75 | 120.75 | 44.15 | False | None | None | False | None | False | 5331.1125 | 0 | 3151125 | 108608 | None | CODE30 | First Floor: Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11286.56 | 11286.56 | 3.01 | False | None | None | False | None | False | 33972.5456 | 0 | 3151126 | 108608 | None | CODE31 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8367.45 | 8367.45 | 21.5 | False | None | None | False | None | False | 179900.175 | 0 | 3151127 | 108608 | None | CODE32 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Sqm | 1024.8 | 1024.8 | 34.33 | False | None | None | False | None | False | 35181.384 | 0 | 3151128 | 108608 | None | CODE33 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6555.15 | 6555.15 | 0.5 | False | None | None | False | None | False | 3277.575 | 0 | 3151129 | 108608 | None | CODE34 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11138.4 | 11138.4 | 10.01 | False | None | None | False | None | False | 111495.384 | 0 | 3151130 | 108608 | None | CODE35 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10094.18 | 10094.18 | 0.24 | False | None | None | False | None | False | 2422.6032 | 0 | 3151131 | 108608 | None | CODE36 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10442.25 | 10442.25 | 13.92 | False | None | None | False | None | False | 145356.12 | 0 | 3151132 | 108608 | None | CODE37 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. for Building | Tonne | 94510.5 | 94510.5 | 2.79 | False | None | None | False | None | False | 263684.295 | 0 | 3151133 | 108608 | None | CODE38 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 4701.9 | 4701.9 | 9.81 | False | None | None | False | None | False | 46125.639 | 0 | 3151134 | 108608 | None | CODE39 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer- in-Charge. | Kgs | 144.9 | 144.9 | 64.8 | False | None | None | False | None | False | 9389.52 | 0 | 3151135 | 108608 | None | CODE40 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement: 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 221.55 | 221.55 | 104.69 | False | None | None | False | None | False | 23194.0695 | 0 | 3151136 | 108608 | None | CODE41 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 267.75 | 267.75 | 81.07 | False | None | None | False | None | False | 21706.4925 | 0 | 3151137 | 108608 | None | CODE42 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 366.45 | 366.45 | 217.07 | False | None | None | False | None | False | 79545.3015 | 0 | 3151138 | 108608 | None | CODE43 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 105.0 | 105.0 | 149.86 | False | None | None | False | None | False | 15735.3 | 0 | 3151139 | 108608 | None | CODE44 | Flooring with 25mm thick polished shahabad slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. | Sqm | 1717.8 | 1717.8 | 77.71 | False | None | None | False | None | False | 133490.238 | 0 | 3151140 | 108608 | None | CODE45 | Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. | Sqm | 1461.6 | 1461.6 | 19.8 | False | None | None | False | None | False | 28939.68 | 0 | 3151141 | 108608 | None | CODE46 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 133.35 | 133.35 | 149.86 | False | None | None | False | None | False | 19983.831 | 0 | 3151142 | 108608 | None | CODE47 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 182.7 | 182.7 | 148.93 | False | None | None | False | None | False | 27209.511 | 0 | 3151143 | 108608 | None | CODE48 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 120.75 | 120.75 | 22.07 | False | None | None | False | None | False | 2664.9525 | 0 | 3151144 | 108608 | None | CODE49 | ELECTRICAL: Supplying heavy gauge PVC conduit pipe mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2 mm thick | Mtr | 61.0 | 61.0 | 100.0 | False | None | None | False | None | False | 6100.0 | 0 | 3151145 | 108608 | None | CODE50 | ELECTRICAL: Supplying heavy gauge PVC conduit pipe mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25 mm dia 2 mm thick | Mtr | 70.0 | 70.0 | 50.0 | False | None | None | False | None | False | 3500.0 | 0 | 3151146 | 108608 | None | CODE51 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 75 x 75 x 65 mm | Each | 100.0 | 100.0 | 3.0 | False | None | None | False | None | False | 300.0 | 0 | 3151147 | 108608 | None | CODE52 | Supplying and fixing PVC/metal conduit Deep junction box 19/20 mm deep Junction box | Each | 49.0 | 49.0 | 10.0 | False | None | None | False | None | False | 490.0 | 0 | 3151148 | 108608 | None | CODE53 | Supplying And Fixing Metal Fan Box with Round Hook. | Nos | 85.0 | 85.0 | 6.0 | False | None | None | False | None | False | 510.0 | 0 | 3151149 | 108608 | None | CODE54 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3m from tapping point to out let via switch box | Point | 251.0 | 251.0 | 15.0 | False | None | None | False | None | False | 3765.0 | 0 | 3151150 | 108608 | None | CODE55 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3m upto 6m from tapping point to out let via switch box | Point | 361.0 | 361.0 | 15.0 | False | None | None | False | None | False | 5415.0 | 0 | 3151151 | 108608 | None | CODE56 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5sqmm | Mtr | 26.0 | 26.0 | 200.0 | False | None | None | False | None | False | 5200.0 | 0 | 3151152 | 108608 | None | CODE57 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5sqmm | Mtr | 40.0 | 40.0 | 200.0 | False | None | None | False | None | False | 8000.0 | 0 | 3151153 | 108608 | None | CODE58 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8Module | Each | 200.0 | 200.0 | 3.0 | False | None | None | False | None | False | 600.0 | 0 | 3151154 | 108608 | None | CODE59 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch | Each | 88.0 | 88.0 | 30.0 | False | None | None | False | None | False | 2640.0 | 0 | 3151155 | 108608 | None | CODE60 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator | Each | 313.0 | 313.0 | 6.0 | False | None | None | False | None | False | 1878.0 | 0 | 3151156 | 108608 | None | CODE61 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16A One Way Switch | Each | 249.0 | 249.0 | 6.0 | False | None | None | False | None | False | 1494.0 | 0 | 3151157 | 108608 | None | CODE62 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16A Universal Socket | Each | 249.0 | 249.0 | 3.0 | False | None | None | False | None | False | 747.0 | 0 | 3151158 | 108608 | None | CODE63 | Supplying and fixing 32A security and energy saving DP switch with key tag suitable to operate on 230 V, 50Hz AC supply & completely wired on existing box. | Each | 747.0 | 747.0 | 2.0 | False | None | None | False | None | False | 1494.0 | 0 | 3151159 | 108608 | None | CODE64 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32Amps SP | Each | 523.0 | 523.0 | 1.0 | False | None | None | False | None | False | 523.0 | 0 | 3151160 | 108608 | None | CODE65 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. II-Double Door 8 Way SP & N | Each | 1695.0 | 1695.0 | 2.0 | False | None | None | False | None | False | 3390.0 | 0 | 3151161 | 108608 | None | CODE66 | Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. | Job | 3750.0 | 3750.0 | 1.0 | False | None | None | False | None | False | 3750.0 | 0 | 3151162 | 108608 | None | CODE67 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200 mm) Regular model | Each | 2085.0 | 2085.0 | 6.0 | False | None | None | False | None | False | 12510.0 | 0 | 3151163 | 108608 | None | CODE68 | Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI less than 80. Power Input: 220-240V@ 50/60Hz & Power factor less than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 W | Each | 740.0 | 740.0 | 6.0 | False | None | None | False | None | False | 4440.0 | 0 | 3151164 | 108608 | None | CODE69 | Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clA and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden
board and wired. | Each | 281.0 | 281.0 | 6.0 | False | None | None | False | None | False | 1686.0 | 0 |
|