3147209 | 108368 | None | PWD Common SR Vol II 2023-24 It No,5.1.1 Page No09 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :) Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5891.55 | 5891.55 | 1.566 | False | None | None | False | None | False | 9226.1673 | 0 |
3147210 | 108368 | None | PWD Common SR Vol II 2023-24 It No,2.5.1 Page No17 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for columns | Cum | 11834.55 | 11834.55 | 2.804 | False | None | None | False | None | False | 33184.0782 | 0 |
3147211 | 108368 | None | PWD Common SR Vol II 2023-24 It No,2.5.1 Page No17 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for beams | Cum | 11138.4 | 11138.4 | 8.229 | False | None | None | False | None | False | 91657.8936 | 0 |
3147212 | 108368 | None | PWD Common SR Vol II 2023-24 It No,2.5.1 Page No17 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for roof slabs | Cum | 10442.25 | 10442.25 | 19.027 | False | None | None | False | None | False | 198684.69075 | 0 |
3147213 | 108368 | None | PWD Common SR Vol II 2023-24 It No,2.11 Page No18 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification for Buildings | t | 93929.85 | 93929.85 | 3.036 | False | None | None | False | None | False | 285171.0246 | 0 |
3147214 | 108368 | None | PWD Common SR Vol II 2023-24 It No,6.8 Page No14 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8367.45 | 8367.45 | 6.661 | False | None | None | False | None | False | 55735.58445 | 0 |
3147215 | 108368 | None | PWD Common SR Vol II 2023-24 It No,12.12 Page No99 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications | Cum | 130412.1 | 130412.1 | 0.869 | False | None | None | False | None | False | 113328.1149 | 0 |
3147216 | 108368 | None | PWD Comm SR Vol II 2023-24 It No,12.51 Page No104 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications | No | 1066.8 | 1066.8 | 2.0 | False | None | None | False | None | False | 2133.6 | 0 |
3147217 | 108368 | None | PWD Comm SR Vol II 2023-24 It No,12.52 Page No104 | Fixing of window frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debries with lead upto 50 m. including cost of materials, labour charges, complete as per specifications | No | 811.65 | 811.65 | 8.0 | False | None | None | False | None | False | 6493.2 | 0 |
3147218 | 108368 | None | PWD Comm SR Vol II 2023-24 It No,12.18 Page No100 | Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with, stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures ) | Sqm | 6904.8 | 6904.8 | 5.04 | False | None | None | False | None | False | 34800.192 | 0 |
3147219 | 108368 | None | PWD Comm SR Vol II 2023-24 It No,12.28 Page No100 | Providing and fixing in position fully panelled shutters of Mathi/Nandi wood for windows with stiles and rails of 30mm thick, 75mm wide in two halves with panels of 20mm thick including cost of materials,
labour charges, usage charges complete as per specifications. (excluding cost of fixtures) | Sqm | 6543.6 | 6543.6 | 11.52 | False | None | None | False | None | False | 75382.272 | 0 |
3147220 | 108368 | None | PWD Common SR Vol II 2023-24 It No,8.5.2 Page No41 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 366.45 | 366.45 | 143.049 | False | None | None | False | None | False | 52420.30605 | 0 |
3147221 | 108368 | None | PWD Common SR Vol II 2023-24 It No,8.5.1 Page No42 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:3 (1 cement: 3 fine sand) including rounding off corners wherever required smooth
rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 384.3 | 384.3 | 402.2 | False | None | None | False | None | False | 154565.46 | 0 |
3147222 | 108368 | None | PWD Common SR Vol II 2023-24 It No,9.23 Page No63 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm
thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent | Sqm | 2589.3 | 2589.3 | 132.728 | False | None | None | False | None | False | 343672.6104 | 0 |
3147223 | 108368 | None | PWD Common SR Vol II 2023-24 It No,8.28 Page No45 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 93.45 | 93.45 | 232.88 | False | None | None | False | None | False | 21762.636 | 0 |
3147224 | 108368 | None | PWD Common SR Vol II 2023-24 It No,8.25 Page No48 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 143.85 | 143.85 | 312.369 | False | None | None | False | None | False | 44934.28065 | 0 |
3147225 | 108368 | None | ELE Com SR Vol VI 2023-24 It No,1.2.3 Page No2 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable sizebends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary.32 mm dia 2.5 mm thick | m | 108.15 | 108.15 | 60.0 | False | None | None | False | None | False | 6489.0 | 0 |
3147226 | 108368 | None | ELE Com SR Vol VI 2023-24 It No,1.3.2 Page No2 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and
run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25 mm dia 2 mm thick | m | 82.95 | 82.95 | 60.0 | False | None | None | False | None | False | 4977.0 | 0 |
3147227 | 108368 | None | ELE Com SR Vol VI 2023-24 It No,1.4.4 Page No2 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.180 x 90 x 65 mm | No | 169.05 | 169.05 | 4.0 | False | None | None | False | None | False | 676.2 | 0 |
3147228 | 108368 | None | ELE Com SR Vol VI 2023-24 It No,1.6.1 Page No2 | Supplying and flush mounting teak wooden box with out front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete.12" x 12" x 3" | No | 126.0 | 126.0 | 4.0 | False | None | None | False | None | False | 504.0 | 0 |
3147229 | 108368 | None | ELE Com SR Vol VI 2023-24 It No,2.11 Page No2 | Point wiring using Copper wire with switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3m from tapping point to out let via switch | No | 299.25 | 299.25 | 8.0 | False | None | None | False | None | False | 2394.0 | 0 |
3147230 | 108368 | None | ELE Com SR Vol VI 2023-24 It No,2.12 Page No2 | Point wiring using Copper wire with switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Medium point above 3m upto 6m from tapping point to out let via switch | No | 413.7 | 413.7 | 4.0 | False | None | None | False | None | False | 1654.8 | 0 |
3147231 | 108368 | None | ELE Com SR Vol VI 2023-24 It No,2.13 Page No2 | Point wiring using Copper wire with switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Long point above 6 Mtr up to 10 Mtr from tapping point to out let via switch | No | 598.5 | 598.5 | 2.0 | False | None | None | False | None | False | 1197.0 | 0 |
3147232 | 108368 | None | ELE Com SR Vol VI 2023-24 It No,3.1.2 Page No5 | Supplying 6A flush type socket and 6A flush type SP switch either surface /flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over aflush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 Way | No | 154.35 | 154.35 | 4.0 | False | None | None | False | None | False | 617.4 | 0 |
3147233 | 108368 | None | ELE Common SR Vol VI 2023-24 It No,6.3.1 Page No30 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies for operation on 230 Volts, 50 Cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. | No | 3133.2 | 3133.2 | 4.0 | False | None | None | False | None | False | 12532.8 | 0 |