tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1716205480000 | 0 | None | None | Buildings | CIVIL WORK | 2909980.43 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3139171 | 107905 | None | PWD SR 23-24 Vol-1 Item no. 1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth | Cum | 99.75 | 99.75 | 33.75 | False | None | None | False | None | False | 3366.5625 | 0 | 3139172 | 107905 | None | PWD SR 23-24 Vol-1 Item no. | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 381.15 | 381.15 | 102.07 | False | None | None | False | None | False | 38903.9805 | 0 | 3139173 | 107905 | None | PWD SR 23-24 Vol-1 Item no. 2.1.2 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 13.0 | False | None | None | False | None | False | 77313.6 | 0 | 3139174 | 107905 | None | PWD SR 23-24 Vol-1 Item no. 2.2.1 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6601.35 | 6601.35 | 17.21 | False | None | None | False | None | False | 113609.2335 | 0 | 3139175 | 107905 | None | 2.2.1 | Centering and shuttering charges for footing | Cum | 198.04 | 198.04 | 17.21 | False | None | None | False | None | False | 3408.2684 | 0 | 3139176 | 107905 | None | PWD SR 23-24 Vol-1 Item no. 2.4.2 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6639.15 | 6639.15 | 8.2 | False | None | None | False | None | False | 54441.03 | 0 | 3139177 | 107905 | None | 2.4.2 | Centering and shuttering charges for Columns | Cum | 4647.41 | 4647.41 | 2.23 | False | None | None | False | None | False | 10363.7243 | 0 | 3139178 | 107905 | None | 2.4.2 | Centering and shuttering charges for Plinth Beams | Cum | 3319.58 | 3319.58 | 5.96 | False | None | None | False | None | False | 19784.6968 | 0 | 3139179 | 107905 | None | PWD SR 23-24 Vol-1 Item no. 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6961.5 | 6961.5 | 31.26 | False | None | None | False | None | False | 217616.49 | 0 | 3139180 | 107905 | None | 2.5.1 | Centering and shuttering charges for columns | Cum | 4873.05 | 4873.05 | 4.41 | False | None | None | False | None | False | 21490.1505 | 0 | 3139181 | 107905 | None | 2.5.1 | Centering and shuttering charges for Lintel & Beams | Cum | 4176.9 | 4176.9 | 9.37 | False | None | None | False | None | False | 39137.553 | 0 | 3139182 | 107905 | None | 2.5.1 | Centering and shuttering charges for Roof Slab | Cum | 3480.75 | 3480.75 | 16.91 | False | None | None | False | None | False | 58859.4825 | 0 | 3139183 | 107905 | None | 2.5.1 | Centering and shuttering charges for Chajja | Cum | 3132.68 | 3132.68 | 0.57 | False | None | None | False | None | False | 1785.6276 | 0 | 3139184 | 107905 | None | PWD SR 23-24 Vol-1 Item no. 2.11.(a) | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. | Tonne | 93929.85 | 93929.85 | 5.12 | False | None | None | False | None | False | 480920.832 | 0 | 3139185 | 107905 | None | PWD SR 23-24 Vol-2 Item no. | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5891.55 | 5891.55 | 19.92 | False | None | None | False | None | False | 117359.676 | 0 | 3139186 | 107905 | None | PWD SR 23-24 Vol-2 Item no. 5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 22.17 | False | None | None | False | None | False | 148726.3365 | 0 | 3139187 | 107905 | None | PWD SR 23-24 Vol-1 Item no. 1.11 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 454.65 | 454.65 | 78.11 | False | None | None | False | None | False | 35512.7115 | 0 | 3139188 | 107905 | None | PWD SR 23-24 Vol -1 item 2.1.3 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of
machinery, curing, and all the other appurtenances required to complete the
work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6288.45 | 6288.45 | 6.52 | False | None | None | False | None | False | 41000.694 | 0 | 3139189 | 107905 | None | PWD SR 23-24 Vol -2 item | Providing Brick work with common burnt clay Non Modular bricks of
class designation 3.5 in superstructure above plinth level in all shapes and
sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of
all materials, labour, scaffolding and usage charges of machinery & other
incidental charges complete as per the direction of engineer incharge of
work | Cum | 8367.45 | 8367.45 | 47.12 | False | None | None | False | None | False | 394274.244 | 0 | 3139190 | 107905 | None | PWD SR 23-24 Vol -2 item 6.15 | Providing Half brick masonry with common burnt clay Non Modular
bricks of class designation 3.5 in superstructure above plinth level up
to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including
cost of all materials, labour, scaffolding and usage charges of machinery
& other incidental charges complete as per the direction of engineer
incharge of work. | Sqm | 1084.65 | 1084.65 | 30.32 | False | None | None | False | None | False | 32886.588 | 0 | 3139191 | 107905 | None | PWD SR 23-24 Vol -2 item 12.13.1 | Providing Salwood frames of doors, windows, clerestory windows,
ventilators and other frames, wrought, framed or assembled including
making plaster groves (excluding cost of cement concrete and side clamps),
but including cost of materials, labour, usage charges complete as per
specifications. | Cum | 103755.75 | 103755.75 | 0.56 | False | None | None | False | None | False | 58103.22 | 0 | 3139192 | 107905 | None | PWD SR 23-24 Vol -2 item 12.51 | Fixing of door frame in an existing opening including embedding frame in
floor and walls after cutting masonry for holdfasts for embedding holdfast
in cement concrete 1:3:6 of 20mm and down size granite metal painting
two coats of coal tar to sides of frame, making good the damages to walls
and floor as required and disposal of the debris with lead upto 50 m.
including cost of materials, labour charges, complete as per specifications. | No | 1066.8 | 1066.8 | 7.0 | False | None | None | False | None | False | 7467.6 | 0 | 3139193 | 107905 | None | PWD SR 23-24 Vol -2 item 12.21 | Providing and fixing in position fully panelled Matti/Nandi wood shutters
for doors with , stiles and rails of 30mm. thick with bottom and lock rails
180mm wide top rail and stiles 100mm wide as per drawing and panels
of 25mm thick including cost of materials, labour, usage charges complete
as per specifications. (excluding cost of fixtures) | Sqm | 6029.1 | 6029.1 | 14.07 | False | None | None | False | None | False | 84829.437 | 0 | 3139194 | 107905 | None | PWD SR 23-24 Vol -2 item 12.55 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled
Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and
15x15mm for top & bottom rails, covered with heat moulded Prelaminated
PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm
thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom
rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert
for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated
on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC
Designer beading on either side & joined together with solvent cement
adhesive etc., Complete as per manufacturers specification & direction of
Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.
12.55.1 -do- with both side prelam | Sqm | 2484.3 | 2484.3 | 4.72 | False | None | None | False | None | False | 11725.896 | 0 | 3139195 | 107905 | None | PWD SR 23-24 Vol -2 item 11.3 | Providing and fixing in position collapsible steel shutters with vertical
channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size,
with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia
steel pulleys, complete with bolts, nuts, locking arrangement, stoppers,
handles, including applying a priming coat of approved steel primer
including cost of materials ,labour, usage charges of machinery complete
as per specifications and as per directions of the Engineer-in-Charge.
| Sqm | 8689.8 | 8689.8 | 3.15 | False | None | None | False | None | False | 27372.87 | 0 | 3139196 | 107905 | None | PWD SR 23-24 Vol -2 item 12.90 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi
chambered UPVC(Matching to RAL-9016) sections and with minimum
TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and
lead free, gaskets -grey colour having isolated drainage and reinforced with
Galvanized Iron profile through-out the window frame. The outer frame
having an overall size of 108mm width x 45mmheight with reinforcement
of 1mm thickness and Sash with overall size of 39mm x 75mm with GI
reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded
Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows
shall be provided with 6mm plain float glass, standard hardware& Multi
point locking system with touch lock. Wall thickness of frame & sash shall
be of 2mm2.5mm. Maximum possible size 2419mm x 2200mm. (The
cost is inclusive of all fixtures and separate charges for minor T&P's shall
not be made | Sqm | 7070.7 | 7070.7 | 8.78 | False | None | None | False | None | False | 62080.746 | 0 | 3139197 | 107905 | None | PWD SR 23-24 Vol -2 item 11.34B | Providing and fixing M.S. grills of required pattern in frames of windows
etc. with M.S. flats, square or round bars etc. including priming coat with
approved steel primer all complete. Fixed to openings /wooden frames
with rawl plugs screws etc | Kgs | 192.15 | 192.15 | 282.56 | False | None | None | False | None | False | 54293.904 | 0 | 3139198 | 107905 | None | PWD SR 23-24 Vol -2 item | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3
fine sand) on concrete surface / ceilings including rounding off corners
wherever required smooth rendering, providing and removing scaffolding,
including cost of materials, labour, curing complete as per specifications
and as per directions of Engineer-in-charge.
| Sqm | 221.55 | 221.55 | 101.99 | False | None | None | False | None | False | 22595.8845 | 0 | 3139199 | 107905 | None | PWD SR 23-24 Vol -2 item 8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement:
4 fine sand) to brick masonry including rounding off corners wherever
required smooth rendering, providing and removing scaffolding, including
cost of materials, labour, curing complete as per specifications and as per
directions of Engineer-in-charge | Sqm | 267.75 | 267.75 | 369.56 | False | None | None | False | None | False | 98949.69 | 0 | 3139200 | 107905 | None | PWD SR 23-24 Vol -2 item 8.51 | Providing and applying white cement based putty of average thickness
1 mm, of approved brand and manufacturer, over the plastered
wall surface to prepare the surface even and smooth complete as per
specifications and as per directions of Engineer in charge. | Sqm | 105.0 | 105.0 | 471.56 | False | None | None | False | None | False | 49513.8 | 0 | 3139201 | 107905 | None | PWD SR 23-24 Vol -2 item 8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick
wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners
wherever required smooth rendering, providing and removing scaffolding,
including cost of materials, labour, curing complete as per specifications
and as per directions of Engineer-in-charge. | Sqm | 309.75 | 309.75 | 255.14 | False | None | None | False | None | False | 79029.615 | 0 | 3139202 | 107905 | None | PWD SR 23-24 Vol -2 item 9.17.2 | Providing and laying Vitrified tiles with thickness 9-10 mm in different
sizes with water absorption less than 0.08 % and conforming to I.S. 15622,
of approved make, in all colours & shade, over 12 mm thick bed of cement
mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry
@ 3.3 kg/ m2 including grouting the joint with white cement & matching
pigments etc. complete. Size of Tile 600x600 mm | Sqm | 1233.75 | 1233.75 | 79.16 | False | None | None | False | None | False | 97663.65 | 0 | 3139203 | 107905 | None | PWD SR 23-24 Vol -2 item 9.9 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm
(thickness to be specified by the manufacturer) of 1st quality conforming
to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume
Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse
sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing
the joints with white cement and matching pigment etc., complete. | Sqm | 1129.8 | 1129.8 | 7.27 | False | None | None | False | None | False | 8213.646 | 0 | 3139204 | 107905 | None | PWD SR 23-24 Vol -2 item 9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm
thick on 10mm thick cement plaster 1:3 and jointed with white cement
slurry over existing rough plaster surface using glazed tiles of approved
make and size including cost of materials, labour, complete as per
specifications. | Sqm | 1521.45 | 1521.45 | 107.55 | False | None | None | False | None | False | 163631.9475 | 0 | 3139205 | 107905 | None | PWD SR 23-24 Vol -2 item 8.25 | Distempering with oil bound washable distemper of approved brand
and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly
brooming the surface to remove all dirt, dust, mortar drops and foreign
matter including preparing the surface even and sand paper smooth, cost
of materials, labour complete as per specifications and as per directions
of Engineer-in-charge | Sqm | 143.85 | 143.85 | 471.56 | False | None | None | False | None | False | 67833.906 | 0 | 3139206 | 107905 | None | PWD SR 23-24 Vol -2 item 8.30 | Finishing walls with Acrylic Smooth exterior paint of required shade :New
work (Two coat applied @ 1.67L/10 m² over and including priming coat of
exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality
to give an even shade, after thoroughly brooming the surface to remove all
dirt, dust, mortar drops and foreign matter including preparing the surface
even and sand paper smooth, cost of materials, labour complete as per
specifications and as per directions of Engineer-in-charge. | Sqm | 182.7 | 182.7 | 255.14 | False | None | None | False | None | False | 46614.078 | 0 | 3139207 | 107905 | None | PWD SR 23-24 Vol -2 item 8.33.2 | Painting wood work with Deluxe Multi Surface Paint of required shade.
Two coat applied @ 0.90L/10 m² over an under coat of primer applied
@0.75 L/10 m² of approved brand and manufacture to give an even shade
including preparing the surface after thorougly cleaning oil, grease, dirt
and foreign matter, sand papering and knotting , cost of materials, labour
complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 144.9 | 144.9 | 26.19 | False | None | None | False | None | False | 3794.931 | 0 | 3139208 | 107905 | None | PWD SR 23-24 Vol -2 item 8.33.3 | Painting Steel work with Deluxe Multi Surface Paint to give an even
shade. Two coat applied @ 0.90L/10 m² over an under coat of primer
applied @ 0.80 L/10 m² of approved brand and manufacture including
preparing the surface after thorougly cleaning oil, grease, dirt and foreign
matter, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge | Sqm | 145.95 | 145.95 | 33.21 | False | None | None | False | None | False | 4846.9995 | 0 | 3139209 | 107905 | None | PWD SR 23-24 Vol -2 item 11.26.1 | Providing and fixing hand rail of approved size by welding etc. to steel
ladder railing, balcony railing, staircase railing and similar works,
including applying priming coat of approved steel primer. M.S. tube
including cost of materials, labour, usage charges of machinery complete
as per specifications and as per directions of the Engineer-in-Charge.
| Kg | 144.9 | 144.9 | 270.27 | False | None | None | False | None | False | 39162.123 | 0 | 3139210 | 107905 | None | ITEM1 | Providing Door fixtures | Each | 1210.0 | 1210.0 | 7.0 | False | None | None | False | None | False | 8470.0 | 0 | 3139211 | 107905 | None | item2 | Providing window fixtures | Each | 605.0 | 605.0 | 5.0 | False | None | None | False | None | False | 3025.0 | 0 |
| 1716205480000 | 0 | None | None | Buildings | ELECTRICAL WORK | 137762.4 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3139212 | 107906 | None | PWD Electrical SR 23-24, P. No. 2 It. No. 1.2.1 | Concealed couduit Supplying heavy gauge PVC conduit pipe ……mm dia .mm thick confirming to IS 2509 with suitable
size bends, metal/PVC junction boxes, adhesive paste etc., and
running before concreting the slab. The conduit should be tied
to the reinforcement rods by using binding wires and unused
ways of junction boxes and pipe ends should be covered using
PVC end enclosures, run with 18SWG GI fish wire wherever
necessary 19/20mm dia 2mm | Rmtr | 66.0 | 66.0 | 150.0 | False | None | None | False | None | False | 9900.0 | 0 | 3139213 | 107906 | None | PWD Electrical SR 23-24, P. No. 2 It. No. 1.3.1 | Supplying heavy gauge PVC Conduit Pipe ….dia .mm
thick with suitable size bends, metal junction boxes adhesive
paste etc., by groove cutting in the wall and fixing by bracing U
or J hooks and cement plastering up to the wall surface
and run with 18 SWG GI fish wire run throughout the conduit 19/20mm dia 2mm | Rmtr | 68.0 | 68.0 | 60.0 | False | None | None | False | None | False | 4080.0 | 0 | 3139214 | 107906 | None | PWD Electrical SR 23-24, P. No. 5 It. No. 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed
system of wiring with specified IS-694:confirming to latest
amendments 2.5 Sqmm | Mtr | 42.0 | 42.0 | 150.0 | False | None | None | False | None | False | 6300.0 | 0 | 3139215 | 107906 | None | PWD Electrical SR 23-24, P. No. 5 It. No. 2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed
system of wiring with specified IS-694:confirming to latest
amendments 4 Sqmm | Mtr | 63.0 | 63.0 | 100.0 | False | None | None | False | None | False | 6300.0 | 0 | 3139216 | 107906 | None | PWD Electrical SR 23-24, P. No. 8 It. No. 3.4.3 | Supplying and flush mounting powder coated / galvanized
metal box suitable for mounting modular switch plates. The box
should be firmly flush mounted after due groove cutting in
Brick/Stone/C.C wall 4 - 5 way | Rs | 177.0 | 177.0 | 8.0 | False | None | None | False | None | False | 1416.0 | 0 | 3139217 | 107906 | None | PWD Electrical SR 23-24, P. No. 8 It. No. 3.5.3 | Supplying andfixing superior quality modular switch mounting
polycarbonate plate with necessary supporting back plate with
required nos. of machine screws, bolts nuts etc.,complete on the
existing metal/PVC box. 4 Module | No | 175.0 | 175.0 | 8.0 | False | None | None | False | None | False | 1400.0 | 0 | 3139218 | 107906 | None | PWD Electrical SR 23-24, P. No. 9 It. No. 3.6.1 | Supplying and fixing of modular switch & connected accessories
on existing modular switch plate as per IS 3854 and IS 1293 6Amps one way | No | 102.0 | 102.0 | 38.0 | False | None | None | False | None | False | 3876.0 | 0 | 3139219 | 107906 | None | PWD Electrical SR 23-24, P. No. 9 It. No. 3.6.3 | Supplying and fixing of modular switch & connected accessories
on existing modular switch plate as per IS 3854 and IS 1293 6Amps 3way socket | No | 171.0 | 171.0 | 8.0 | False | None | None | False | None | False | 1368.0 | 0 | 3139220 | 107906 | None | PWD Electrical SR 23-24, P. No. 9 It. No. 3.6.4 | Supplying and fixing of modular switch & connected accessories
on existing modular switch plate as per IS 3854 and IS 1293. Stepped Regulator | No | 357.0 | 357.0 | 10.0 | False | None | None | False | None | False | 3570.0 | 0 | 3139221 | 107906 | None | PWD Electrical SR 23-24, P. No. 17 It. No. 5.18.1 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with
Short circuit breaking capacity of 10K and complete wiring as
required confirming to IEC 60898 6-32Amps SP | No | 415.0 | 415.0 | 5.0 | False | None | None | False | None | False | 2075.0 | 0 | 3139222 | 107906 | None | PWD Electrical SR 23-24, P. No. 28 It. No. 5.19.7 | Supplying and fixing regular MCB distribution boards on wall /
wood board / flush mounting using required clamps, bolts, nuts
etc., with provision for fixing suitable type capacity MCB's
single phase / 3 phase / single door with powder coated
painting. Made out of 14 SWG MS enclosure 6 Way SP & N | No | 1791.0 | 1791.0 | 4.0 | False | None | None | False | None | False | 7164.0 | 0 | 3139223 | 107906 | None | PWD Electrical SR 23-24, P. No. 20 It. No. 5.41.2 | Supplying and fixing angle iron frame work fabricated out of
M.S. angle iron. and M.S. flat … with bolts, washers etc., and
painted with 2 coats of red oxide and then two coats of
approved paint. 50x50x6mm | Rmtr | 395.0 | 395.0 | 10.0 | False | None | None | False | None | False | 3950.0 | 0 | 3139224 | 107906 | None | PWD Electrical SR 23-24, P. No. 20 It. No. 5.42.2 | Fabricating supplying and mounting MS box made out …
SWG suitable for floor / wall mounting, fully weather proof
with provision for better heat dissipation, provided with hinged
front cover, equipped with tamper proof locking arrangements,
with suitable size clamps | Sq CM | 0.43 | 0.43 | 3500.0 | False | None | None | False | None | False | 1505.0 | 0 | 3139225 | 107906 | None | PWD Electrical SR 23-24, P. No. 55 It. No. 12.60. | Supplying & Fixing Chemical earthling for grounding.
Conduits, IC cut-outs& otherequipments backfill compound which is non- corrosive, thermally conductive, potential to
permissible limits, superior Fault conduction capacity,
nontoxic, weathe resistance & capable of achieving ohmic value Earthing | Kit | 4528.0 | 4528.0 | 1.0 | False | None | None | False | None | False | 4528.0 | 0 | 3139226 | 107906 | None | PWD Electrical SR 23-24, P. No. 41 It. No. 6.6.2 | Digging of trench of 0.60m deep x 0.50mtrs wide refilling the
trench to the required ground level and consolidating etc.,
complete In hard soil | Mtr | 102.0 | 102.0 | 5.0 | False | None | None | False | None | False | 510.0 | 0 | 3139227 | 107906 | None | PWD Electrical SR 23-24, P. No. 40 It. No. 6.4.4 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant
PVC insulated, PVC extruded Inner sheath armoured UG LT
cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip
thickness in average +5% and resistivity 14 Ohms/Kms (Max) as
per IS-3975 4 core 16 Sqmm | Rmtr | 150.0 | 150.0 | 10.0 | False | None | None | False | None | False | 1500.0 | 0 | 3139228 | 107906 | None | PWD Electrical SR 23-24, P. No. 41 It. No. 6.5.1 | Labour charges for laying of 1.1KV class UG cable when
supplied agency in existing trench GI pipe/stonewere pipe/on
wall/on pole as required exising trench/duct
6 to 16 Sqmm | Mtr | 11.88 | 11.88 | 5.0 | False | None | None | False | None | False | 59.4 | 0 | 3139229 | 107906 | None | PWD Electrical SR 23-24, P. No. 30 It. No. 6.3.1 | Supplying capacitor type ceiling fan complete with down rod
blades, snackles, canopies etc., for operation on 230 volts, 50
cycles. Single phase AC supply confirming to IS-374-1979 and
with double ball bearing system. 48" sweep (1200mm) regular
model | No | 2984.0 | 2984.0 | 12.0 | False | None | None | False | None | False | 35808.0 | 0 | 3139230 | 107906 | None | PWD Electrical SR 23-24, P. No. 57 It. No. 13.11 | Fixing a ceiling / wall mounting fan of all capacities and all
types, with necessary clamps and 'S' hook made out of 15mm
dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted
wire of approved quality, mounted on a suitable size wooden | No | 315.0 | 315.0 | 12.0 | False | None | None | False | None | False | 3780.0 | 0 | 3139231 | 107906 | None | PWD Electrical SR 23-24, P. No. 64 It. No. 11.3.2 | Supplying of .feet - PVC Batten with integrated LED
tube.W with high quality diffuser with Life of 25000 burning
hours & 70% lumen maintenance with CRI 80. Power Input:
220-240V @ 50/60Hz & Power factor 0.9 along with CE
approved. 2 years Warranty against any manufacturing defect
working under standard electrical condition. | No | 690.0 | 690.0 | 20.0 | False | None | None | False | None | False | 13800.0 | 0 | 3139232 | 107906 | None | PWD Electrical SR 23-24, P. No. 56 It. No. 13.7 | Fixing all types and all capacities flourescent/false ceiling/spot
light/CFL fittings indoor on the wall/ceiling/rafters/girders
using 23/0.0076" twin twisted PVC insulated wires, required
nos. of round blcks and clamps (if required) on
wall/ceiling/rafters/girders. on wall/ceiling | No | 122.0 | 122.0 | 20.0 | False | None | None | False | None | False | 2440.0 | 0 | 3139233 | 107906 | None | PWD ELE SR 23-24 ITEM 5.18.8 | Supplying & fixing miniature circuit breakers on existing MCB
distribution boards using necessary fixing materials and 'C' Type
curve, indicator ON/OFF, energy cross-3 with Short circuit breaking
capacity of 10K and complete wiring as required confirming to IEC
60898. 40 A TPN | No | 3044.0 | 3044.0 | 2.0 | False | None | None | False | None | False | 6088.0 | 0 | 3139234 | 107906 | None | PWD ELE SR 23-24 ITEM 11.8.6 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing
body for optimal thermal dissipation. Lamp compartment comprising of anti
glare clear diffuser with Injection moulded polycarbonate material, delivering
superior light output Rated life Burning Hrs 50000 hr @ Lumen
Maintenance of 70%, maximum light intensity should be between 60 degrees to
70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact
resistance of complete luminaire IK08. Power Factor 0.9 with mains,
Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/
miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to
50mm. Universal Voltage driver to operate wide voltage range from 100V to
270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 &
LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with
single screw to ensure ease of maintenance at the sight site location with
minimized minimal tools. LED Light fixture with .W System Power
consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire
manufacturer should have in-house facility accredited by NABL/CPRI &
any Government certified agency & Design & Development facility
certified by ISO 9001:2008. Housing with supplier word mark /name shall be
Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years
against any manufacturing defect working under standard electrical conditions as
mentioned above should be given by LED manufacturer & Cree/Nichia/
Lumileds/Osram make LED Source. LED Streetlight 150 W | Each | 14705.0 | 14705.0 | 1.0 | False | None | None | False | None | False | 14705.0 | 0 | 3139235 | 107906 | None | 13.2.3 | Supplying and Fixing.mm dia clampsss A GI pipe bracket upto
2.7 meters long terminated with a reducing collar of 40x25mm to
which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL
street light fitting of all capacities on rail/RCC/wall/tubular pole,
using suitable clamps, bolts, nuts and wiring using suitable capacity
wires Using 40mm dia G.I.Pipe | No | 1478.0 | 1478.0 | 1.0 | False | None | None | False | None | False | 1478.0 | 0 | 3139236 | 107906 | None | 13.5 | Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over
existing pole / wall ceiling including clamps, bolts, nuts and wiring
using suitable capacity wires. | No | 162.0 | 162.0 | 1.0 | False | None | None | False | None | False | 162.0 | 0 |
| 1716205480000 | 0 | None | None | Buildings | Borewell | 330733.45 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3139237 | 107907 | None | RDW&SD SR 23-24 VOL-5 ITEM NO. 12.4 | Geophysical investigation at site for sinking borewells for Providing
drinking water to the habitation either through the Hand Pump MWS
or P.W.S.S, by vertical electrical sounding by adopting Venner or
Schlumbergers's method, including reconnaissance survey of geological
formation. Geophysical investigation of existing ground water in the
vicinity, its quality, quantity and acceptability of the users, indicating
the location of the site, recommended depth of casing pipe required to
seal the top unconsolidated formation including an extra depth of 1.0
metre in consolidated formation for proper seating of casing pipe, depth
of drilling required to cover full depth of aquifer proposed to be tapped,
probable yield and other information required including transportation
of instruments and accessories to work site, engaging technical personal
and labour required etc. NOTE: 1) Additional rate on item 1&2 is
allowed for drilling in over burden and fixing Casing pipes beyond 20
M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%,
b) Above 30 M - 30% (Measurement of overburden is restricted to the
depth of casing pipe fixed excluding initial depth of 20M and projection
above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry
Borewell towards yield test | No | 5552.4 | 5552.4 | 1.0 | False | None | None | False | None | False | 5552.4 | 0 | 3139238 | 107907 | None | RDW&SD SR 23-24 VOL-5 ITEM NO. 12.1.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every
50m depth)
12.1.1 Borewell depth of 0 to 50 Mtrs | Mtr | 388.5 | 388.5 | 50.0 | False | None | None | False | None | False | 19425.0 | 0 | 3139239 | 107907 | None | 12.1.2 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every
50m depth)
Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every
50m depth)
12.1.2 Borewell depth of 50 to 100 Mtrs | m | 487.2 | 487.2 | 50.0 | False | None | None | False | None | False | 24360.0 | 0 | 3139240 | 107907 | None | 12.1.3 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every
50m depth)
12.1.3 Borewell depth of 100 to 150 Mtrs | m | 517.65 | 517.65 | 50.0 | False | None | None | False | None | False | 25882.5 | 0 | 3139241 | 107907 | None | 12.1.4 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every
50m depth)
12.1.4 Borewell depth of 150 to 200 Mtrs | m | 600.6 | 600.6 | 10.0 | False | None | None | False | None | False | 6006.0 | 0 | 3139242 | 107907 | None | 12.32 | Supply of ISI mark 175mm nominal bore,plain and steel casing pipe
grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and
latest ammendments, electrical resistance welded steel tubes, material
and conforming to IS 1387-1993 and manufactured by basic open
hearth electric or basic oxygen process in random length of 5-7m both
ends.threaded conforming to IS 554-1985 one end fixed with socket
conforming to IS 4270-2001 and the other end with screwed pipes all
shall be responsibaly free from defects. The tubes shall be responsible
straight end should be with ISI marking weighing 25.10kg/m.prices
include Collar-Medium duty | Mtr | 2029.65 | 2029.65 | 8.0 | False | None | None | False | None | False | 16237.2 | 0 | 3139243 | 107907 | None | 12.33 | Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with
all latest amendments if any for any dia. The thickness of plate used for
covering one end shall be 3mm (minimum). The dimensions of caps and
colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments | No | 157.5 | 157.5 | 6.0 | False | None | None | False | None | False | 945.0 | 0 | 3139244 | 107907 | None | 12.34 | Providing and laying at site of work MS casing caps as per IS 1239 (partII) 1982 with all latest amendments if any for any dia. The thickness
of plate used for covering one end shall be 3mm (minimum). The
dimensions of caps and colars shall be strictly as per IS 1239 (Part-II)
1982 with all amendments including cost of material and labour charges
for fixing, if any etc. complete with all lead and lifts and as directed by
the Enginee | No | 172.2 | 172.2 | 1.0 | False | None | None | False | None | False | 172.2 | 0 | 3139245 | 107907 | None | 13.13.6 | Providing Submersible Pump Set of 150mm dia suitable for bore well and
confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt
Motor as per specifications, to work site as per necessary ammendments
and instructions of engineer incharge of work. For 3 HP etc. complete. 13.13.6 5.00 HP - 90 LPM @ 110 m = 15 STG Outlet Dia - 2.00" | Each | 33743.85 | 33743.85 | 1.0 | False | None | None | False | None | False | 33743.85 | 0 | 3139246 | 107907 | None | 13.22.4 | Supply and delivery at site Brand new best make PVC insulated cable of
Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990
with ISI Mark and as per its latest amendments.
13.22.4 1x3x6 Sqm | Mtr | 194.25 | 194.25 | 180.0 | False | None | None | False | None | False | 34965.0 | 0 | 3139247 | 107907 | None | 13.23.1 | Supply and delivery at site of brand new best make pressure gauge
bourdon type as per IS 778/1984 with ISI Mark and as per its latest
amendments.
13.23.1 Size 63 mm | No | 436.8 | 436.8 | 1.0 | False | None | None | False | None | False | 436.8 | 0 | 3139248 | 107907 | None | 13.24.1 | Supply and delivery at site of brand new best make gate valve as per IS
778/1984 with ISI Mark and as per its latest amendments
13.24.1 Size 50 mm | No | 1312.5 | 1312.5 | 1.0 | False | None | None | False | None | False | 1312.5 | 0 | 3139249 | 107907 | None | 13.25.1 | Supply and delivery at site of brand new best make non-return valve as
per IS 778/1984 with ISI Mark and as per its latest amendments
13.25.1 Size 50 mm | No | 1312.5 | 1312.5 | 1.0 | False | None | None | False | None | False | 1312.5 | 0 | 3139250 | 107907 | None | 13.23.2 | Supply, installing,testing and commissioning COMMON control panel
consisting of the following INCOMING:1 No set of Phase indicating
lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog
Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING
for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable
for respective HP 1 No. Electrcal Protection Like single Phase preventor,
under voltage over Volage, under current over current & dry run
protection suitable for the pump described above 1 no Indoor type NOTE:
1) DOL- Direct Online Starter
2) S-D- Star Delta Starter etc. complete 13.23.2 3 to 6 HP pumps | No | 10027.5 | 10027.5 | 1.0 | False | None | None | False | None | False | 10027.5 | 0 | 3139251 | 107907 | None | 13.25 | Supply and delivery at site best indigenous brand new power capacitor as
per IS 2834/1986 with latest amendments with KPTCL authorities and
erection, electrification and commissioning of the same at the location
of respective pump sets. | Kvar | 557.5 | 557.5 | 1.0 | False | None | None | False | None | False | 557.5 | 0 | 3139252 | 107907 | None | 13.28 | Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC
Column pipes with heavy duty collars,rubber profile ring,vibration
control profile ring,freezing and turbulence free leak proof EPDM ring
with ISI mark with its latest amendments | Mtr | 577.5 | 577.5 | 180.0 | False | None | None | False | None | False | 103950.0 | 0 | 3139253 | 107907 | None | 13.29 | Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set
complete suitable for uPVC Column pipes for Submersible pumpsets | Set | 1627.5 | 1627.5 | 1.0 | False | None | None | False | None | False | 1627.5 | 0 | 3139254 | 107907 | None | 13.30 | Supply and delivery at site Accessories for Single Phase pumpset like
SS Groove Nipples,SS Studs & Nuts,Screw Clips &water proof Insulation
Tape etc complete with ISI mark | No | 4725.0 | 4725.0 | 1.0 | False | None | None | False | None | False | 4725.0 | 0 | 3139255 | 107907 | None | 13.31 | Supply and delivery at site Stringing of heavy duty Naylone/PP rope with
ISI etc complete suitable for Single phase Pumpsets. | Rmtr | 42.0 | 42.0 | 180.0 | False | None | None | False | None | False | 7560.0 | 0 | 3139256 | 107907 | None | 13.32 | Labour charges for Erection, Electrification and commissioning of Pump
sets, including aligning and balancing of all items including supply and
erection of two pair of supporting clamps, bore well caps, cable clips and
water tight gland cable protectors, bolts, nuts, valve and gauges,tools and
equipments etc., involved in the job as per specifications, with necessary
tests as per specifications, with testing of as per instructions of engineer
incharge of work. | No | 6825.0 | 6825.0 | 1.0 | False | None | None | False | None | False | 6825.0 | 0 | 3139257 | 107907 | None | 13.34 | Labour charges for erection of outdoor type panel board and meter board
units with all necessary materials and labour, tools and equipments
including providing cement concrete foundation bed etc., complete
as per specification, with testing of as per instructions of engineer
incharge of work.
| Job | 1522.5 | 1522.5 | 1.0 | False | None | None | False | None | False | 1522.5 | 0 | 3139258 | 107907 | None | 13.38.1 | Providing and fixing suitable for 1.1 KV class UG cable filled with
necessary bitumen/insulating compound complete with terminals,
clamps,bolts,nuts and washers etc. with necessary materials and labour
tools and equipments as per instructions of engineer incharge of work.
13.38.1 3 1/2 x 6 Sqm | Rmtr | 393.75 | 393.75 | 25.0 | False | None | None | False | None | False | 9843.75 | 0 | 3139259 | 107907 | None | 13.35.2 | Labour charges for providing connection using insulated sheathed
steel wire cable as per IS 1554/ 1988 with latest amendments from
KPTCL pole to meter board unit, with all necessary materials ,tools and
equipments,as per specificationswith testing of as per instructions of
engineer incharge of work. .
13.35.2 3 1/2 x 6 sqmm | Rmtr | 168.0 | 168.0 | 25.0 | False | None | None | False | None | False | 4200.0 | 0 | 3139260 | 107907 | None | 13.36 | Providing main connection from pole PVC insulated sheathed steel wire
cable in new trench as per IS 1554/ 1988 with latest amendments with
ISI mark from KPTCL pole to meter board unit | Rmtr | 141.75 | 141.75 | 25.0 | False | None | None | False | None | False | 3543.75 | 0 | 3139261 | 107907 | None | item1 | KKRDB Logo Board | Each | 6000.0 | 6000.0 | 1.0 | False | None | None | False | None | False | 6000.0 | 0 |
|
|
---|