createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1716205479820
version2
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee850.00
emd67569.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose04-06-2024 16:08:46
tenderQueryClose03-06-2024 16:00:43
technicalBidOpen05-06-2024 16:10:50
publishedDate22-05-2024 13:28:59
publishedByPostPWD_EE_DIV_BID
publishedByUserKPE14569 - SHIVSHANKER V KAMSHETTY
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonShivshanker kamshetty
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08482226440
mobileNumberNone
tenderSupplierListNone
tenderSchedule
createdTs1716205479863
version4
createdDateNone
modifiedDateNone
tenderNumberPWD/2023-24/BD/WORK_INDENT10006
titleConstruction of ANM Center at Warwatti (B) village in Bhalki Tq. Bidar Dist
descriptionConstruction of ANM Center at Warwatti (B) village in Bhalki Tq. Bidar Dist
categoryWORKS
categoryTextWorks
ecv3378476.28
deptNamePublic Works Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location1692
locationNamePWD Division Office Bidar
provisionalAmount4000000.0
groupOverheadTotal0.0
fileNumberPWD/Bhalki/KKRDB/LU/23-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17162054800000NoneNoneBuildingsCIVIL WORK2909980.43
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3139171107905NonePWD SR 23-24 Vol-1 Item no. 1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depthCum99.7599.7533.75FalseNoneNoneFalseNoneFalse3366.56250
3139172107905NonePWD SR 23-24 Vol-1 Item no. Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depthCum381.15381.15102.07FalseNoneNoneFalseNoneFalse38903.98050
3139173107905NonePWD SR 23-24 Vol-1 Item no. 2.1.2Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum5947.25947.213.0FalseNoneNoneFalseNoneFalse77313.60
3139174107905NonePWD SR 23-24 Vol-1 Item no. 2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6601.356601.3517.21FalseNoneNoneFalseNoneFalse113609.23350
3139175107905None2.2.1Centering and shuttering charges for footingCum198.04198.0417.21FalseNoneNoneFalseNoneFalse3408.26840
3139176107905NonePWD SR 23-24 Vol-1 Item no. 2.4.2Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6639.156639.158.2FalseNoneNoneFalseNoneFalse54441.030
3139177107905None2.4.2Centering and shuttering charges for ColumnsCum4647.414647.412.23FalseNoneNoneFalseNoneFalse10363.72430
3139178107905None2.4.2Centering and shuttering charges for Plinth BeamsCum3319.583319.585.96FalseNoneNoneFalseNoneFalse19784.69680
3139179107905NonePWD SR 23-24 Vol-1 Item no. 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6961.56961.531.26FalseNoneNoneFalseNoneFalse217616.490
3139180107905None2.5.1Centering and shuttering charges for columnsCum4873.054873.054.41FalseNoneNoneFalseNoneFalse21490.15050
3139181107905None2.5.1Centering and shuttering charges for Lintel & BeamsCum4176.94176.99.37FalseNoneNoneFalseNoneFalse39137.5530
3139182107905None2.5.1Centering and shuttering charges for Roof SlabCum3480.753480.7516.91FalseNoneNoneFalseNoneFalse58859.48250
3139183107905None2.5.1Centering and shuttering charges for ChajjaCum3132.683132.680.57FalseNoneNoneFalseNoneFalse1785.62760
3139184107905NonePWD SR 23-24 Vol-1 Item no. 2.11.(a)Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Tonne93929.8593929.855.12FalseNoneNoneFalseNoneFalse480920.8320
3139185107905NonePWD SR 23-24 Vol-2 Item no. Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand)Cum5891.555891.5519.92FalseNoneNoneFalseNoneFalse117359.6760
3139186107905NonePWD SR 23-24 Vol-2 Item no. 5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6708.456708.4522.17FalseNoneNoneFalseNoneFalse148726.33650
3139187107905NonePWD SR 23-24 Vol-1 Item no. 1.11Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum454.65454.6578.11FalseNoneNoneFalseNoneFalse35512.71150
3139188107905NonePWD SR 23-24 Vol -1 item 2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregatesCum6288.456288.456.52FalseNoneNoneFalseNoneFalse41000.6940
3139189107905NonePWD SR 23-24 Vol -2 item Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of workCum8367.458367.4547.12FalseNoneNoneFalseNoneFalse394274.2440
3139190107905NonePWD SR 23-24 Vol -2 item 6.15Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Sqm1084.651084.6530.32FalseNoneNoneFalseNoneFalse32886.5880
3139191107905NonePWD SR 23-24 Vol -2 item 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum103755.75103755.750.56FalseNoneNoneFalseNoneFalse58103.220
3139192107905NonePWD SR 23-24 Vol -2 item 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.No1066.81066.87.0FalseNoneNoneFalseNoneFalse7467.60
3139193107905NonePWD SR 23-24 Vol -2 item 12.21Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with , stiles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures)Sqm6029.16029.114.07FalseNoneNoneFalseNoneFalse84829.4370
3139194107905NonePWD SR 23-24 Vol -2 item 12.55Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. 12.55.1 -do- with both side prelamSqm2484.32484.34.72FalseNoneNoneFalseNoneFalse11725.8960
3139195107905NonePWD SR 23-24 Vol -2 item 11.3Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Sqm8689.88689.83.15FalseNoneNoneFalseNoneFalse27372.870
3139196107905NonePWD SR 23-24 Vol -2 item 12.90Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be madeSqm7070.77070.78.78FalseNoneNoneFalseNoneFalse62080.7460
3139197107905NonePWD SR 23-24 Vol -2 item 11.34BProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etcKgs192.15192.15282.56FalseNoneNoneFalseNoneFalse54293.9040
3139198107905NonePWD SR 23-24 Vol -2 item Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm221.55221.55101.99FalseNoneNoneFalseNoneFalse22595.88450
3139199107905NonePWD SR 23-24 Vol -2 item 8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm267.75267.75369.56FalseNoneNoneFalseNoneFalse98949.690
3139200107905NonePWD SR 23-24 Vol -2 item 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm105.0105.0471.56FalseNoneNoneFalseNoneFalse49513.80
3139201107905NonePWD SR 23-24 Vol -2 item 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm309.75309.75255.14FalseNoneNoneFalseNoneFalse79029.6150
3139202107905NonePWD SR 23-24 Vol -2 item 9.17.2Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mmSqm1233.751233.7579.16FalseNoneNoneFalseNoneFalse97663.650
3139203107905NonePWD SR 23-24 Vol -2 item 9.9Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete.Sqm1129.81129.87.27FalseNoneNoneFalseNoneFalse8213.6460
3139204107905NonePWD SR 23-24 Vol -2 item 9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.Sqm1521.451521.45107.55FalseNoneNoneFalseNoneFalse163631.94750
3139205107905NonePWD SR 23-24 Vol -2 item 8.25Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm143.85143.85471.56FalseNoneNoneFalseNoneFalse67833.9060
3139206107905NonePWD SR 23-24 Vol -2 item 8.30Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm182.7182.7255.14FalseNoneNoneFalseNoneFalse46614.0780
3139207107905NonePWD SR 23-24 Vol -2 item 8.33.2Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @0.75 L/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm144.9144.926.19FalseNoneNoneFalseNoneFalse3794.9310
3139208107905NonePWD SR 23-24 Vol -2 item 8.33.3Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm145.95145.9533.21FalseNoneNoneFalseNoneFalse4846.99950
3139209107905NonePWD SR 23-24 Vol -2 item 11.26.1Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Kg144.9144.9270.27FalseNoneNoneFalseNoneFalse39162.1230
3139210107905NoneITEM1Providing Door fixturesEach1210.01210.07.0FalseNoneNoneFalseNoneFalse8470.00
3139211107905Noneitem2Providing window fixturesEach605.0605.05.0FalseNoneNoneFalseNoneFalse3025.00
17162054800000NoneNoneBuildingsELECTRICAL WORK137762.4
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3139212107906NonePWD Electrical SR 23-24, P. No. 2 It. No. 1.2.1Concealed couduit Supplying heavy gauge PVC conduit pipe ……mm dia .mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20mm dia 2mmRmtr66.066.0150.0FalseNoneNoneFalseNoneFalse9900.00
3139213107906NonePWD Electrical SR 23-24, P. No. 2 It. No. 1.3.1Supplying heavy gauge PVC Conduit Pipe ….dia .mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit 19/20mm dia 2mmRmtr68.068.060.0FalseNoneNoneFalseNoneFalse4080.00
3139214107906NonePWD Electrical SR 23-24, P. No. 5 It. No. 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 2.5 SqmmMtr42.042.0150.0FalseNoneNoneFalseNoneFalse6300.00
3139215107906NonePWD Electrical SR 23-24, P. No. 5 It. No. 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 4 SqmmMtr63.063.0100.0FalseNoneNoneFalseNoneFalse6300.00
3139216107906NonePWD Electrical SR 23-24, P. No. 8 It. No. 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4 - 5 wayRs177.0177.08.0FalseNoneNoneFalseNoneFalse1416.00
3139217107906NonePWD Electrical SR 23-24, P. No. 8 It. No. 3.5.3Supplying andfixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc.,complete on the existing metal/PVC box. 4 ModuleNo175.0175.08.0FalseNoneNoneFalseNoneFalse1400.00
3139218107906NonePWD Electrical SR 23-24, P. No. 9 It. No. 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps one wayNo102.0102.038.0FalseNoneNoneFalseNoneFalse3876.00
3139219107906NonePWD Electrical SR 23-24, P. No. 9 It. No. 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps 3way socketNo171.0171.08.0FalseNoneNoneFalseNoneFalse1368.00
3139220107906NonePWD Electrical SR 23-24, P. No. 9 It. No. 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped RegulatorNo357.0357.010.0FalseNoneNoneFalseNoneFalse3570.00
3139221107906NonePWD Electrical SR 23-24, P. No. 17 It. No. 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SPNo415.0415.05.0FalseNoneNoneFalseNoneFalse2075.00
3139222107906NonePWD Electrical SR 23-24, P. No. 28 It. No. 5.19.7Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure 6 Way SP & NNo1791.01791.04.0FalseNoneNoneFalseNoneFalse7164.00
3139223107906NonePWD Electrical SR 23-24, P. No. 20 It. No. 5.41.2Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 50x50x6mmRmtr395.0395.010.0FalseNoneNoneFalseNoneFalse3950.00
3139224107906NonePWD Electrical SR 23-24, P. No. 20 It. No. 5.42.2Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clampsSq CM0.430.433500.0FalseNoneNoneFalseNoneFalse1505.00
3139225107906NonePWD Electrical SR 23-24, P. No. 55 It. No. 12.60.Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs& otherequipments backfill compound which is non- corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, nontoxic, weathe resistance & capable of achieving ohmic value EarthingKit4528.04528.01.0FalseNoneNoneFalseNoneFalse4528.00
3139226107906NonePWD Electrical SR 23-24, P. No. 41 It. No. 6.6.2Digging of trench of 0.60m deep x 0.50mtrs wide refilling the trench to the required ground level and consolidating etc., complete In hard soilMtr102.0102.05.0FalseNoneNoneFalseNoneFalse510.00
3139227107906NonePWD Electrical SR 23-24, P. No. 40 It. No. 6.4.4Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 4 core 16 SqmmRmtr150.0150.010.0FalseNoneNoneFalseNoneFalse1500.00
3139228107906NonePWD Electrical SR 23-24, P. No. 41 It. No. 6.5.1Labour charges for laying of 1.1KV class UG cable when supplied agency in existing trench GI pipe/stonewere pipe/on wall/on pole as required exising trench/duct 6 to 16 SqmmMtr11.8811.885.0FalseNoneNoneFalseNoneFalse59.40
3139229107906NonePWD Electrical SR 23-24, P. No. 30 It. No. 6.3.1Supplying capacitor type ceiling fan complete with down rod blades, snackles, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply confirming to IS-374-1979 and with double ball bearing system. 48" sweep (1200mm) regular modelNo2984.02984.012.0FalseNoneNoneFalseNoneFalse35808.00
3139230107906NonePWD Electrical SR 23-24, P. No. 57 It. No. 13.11Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size woodenNo315.0315.012.0FalseNoneNoneFalseNoneFalse3780.00
3139231107906NonePWD Electrical SR 23-24, P. No. 64 It. No. 11.3.2Supplying of .feet - PVC Batten with integrated LED tube.W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.No690.0690.020.0FalseNoneNoneFalseNoneFalse13800.00
3139232107906NonePWD Electrical SR 23-24, P. No. 56 It. No. 13.7Fixing all types and all capacities flourescent/false ceiling/spot light/CFL fittings indoor on the wall/ceiling/rafters/girders using 23/0.0076" twin twisted PVC insulated wires, required nos. of round blcks and clamps (if required) on wall/ceiling/rafters/girders. on wall/ceilingNo122.0122.020.0FalseNoneNoneFalseNoneFalse2440.00
3139233107906NonePWD ELE SR 23-24 ITEM 5.18.8Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A TPNNo3044.03044.02.0FalseNoneNoneFalseNoneFalse6088.00
3139234107906NonePWD ELE SR 23-24 ITEM 11.8.6Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 150 WEach14705.014705.01.0FalseNoneNoneFalseNoneFalse14705.00
3139235107906None13.2.3Supplying and Fixing.mm dia clampsss A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires Using 40mm dia G.I.PipeNo1478.01478.01.0FalseNoneNoneFalseNoneFalse1478.00
3139236107906None13.5Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.No162.0162.01.0FalseNoneNoneFalseNoneFalse162.00
17162054800000NoneNoneBuildingsBorewell330733.45
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3139237107907NoneRDW&SD SR 23-24 VOL-5 ITEM NO. 12.4Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield testNo5552.45552.41.0FalseNoneNoneFalseNoneFalse5552.40
3139238107907NoneRDW&SD SR 23-24 VOL-5 ITEM NO. 12.1.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) 12.1.1 Borewell depth of 0 to 50 MtrsMtr388.5388.550.0FalseNoneNoneFalseNoneFalse19425.00
3139239107907None12.1.2Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) 12.1.2 Borewell depth of 50 to 100 Mtrsm487.2487.250.0FalseNoneNoneFalseNoneFalse24360.00
3139240107907None12.1.3Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) 12.1.3 Borewell depth of 100 to 150 Mtrsm517.65517.6550.0FalseNoneNoneFalseNoneFalse25882.50
3139241107907None12.1.4Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) 12.1.4 Borewell depth of 150 to 200 Mtrsm600.6600.610.0FalseNoneNoneFalseNoneFalse6006.00
3139242107907None12.32Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium dutyMtr2029.652029.658.0FalseNoneNoneFalseNoneFalse16237.20
3139243107907None12.33Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendmentsNo157.5157.56.0FalseNoneNoneFalseNoneFalse945.00
3139244107907None12.34Providing and laying at site of work MS casing caps as per IS 1239 (partII) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the EngineeNo172.2172.21.0FalseNoneNoneFalseNoneFalse172.20
3139245107907None13.13.6Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For 3 HP etc. complete. 13.13.6 5.00 HP - 90 LPM @ 110 m = 15 STG Outlet Dia - 2.00"Each33743.8533743.851.0FalseNoneNoneFalseNoneFalse33743.850
3139246107907None13.22.4Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 13.22.4 1x3x6 SqmMtr194.25194.25180.0FalseNoneNoneFalseNoneFalse34965.00
3139247107907None13.23.1Supply and delivery at site of brand new best make pressure gauge bourdon type as per IS 778/1984 with ISI Mark and as per its latest amendments. 13.23.1 Size 63 mmNo436.8436.81.0FalseNoneNoneFalseNoneFalse436.80
3139248107907None13.24.1Supply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as per its latest amendments 13.24.1 Size 50 mmNo1312.51312.51.0FalseNoneNoneFalseNoneFalse1312.50
3139249107907None13.25.1Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments 13.25.1 Size 50 mmNo1312.51312.51.0FalseNoneNoneFalseNoneFalse1312.50
3139250107907None13.23.2Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete 13.23.2 3 to 6 HP pumpsNo10027.510027.51.0FalseNoneNoneFalseNoneFalse10027.50
3139251107907None13.25Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPTCL authorities and erection, electrification and commissioning of the same at the location of respective pump sets.Kvar557.5557.51.0FalseNoneNoneFalseNoneFalse557.50
3139252107907None13.28Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendmentsMtr577.5577.5180.0FalseNoneNoneFalseNoneFalse103950.00
3139253107907None13.29Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsetsSet1627.51627.51.0FalseNoneNoneFalseNoneFalse1627.50
3139254107907None13.30Supply and delivery at site Accessories for Single Phase pumpset like SS Groove Nipples,SS Studs & Nuts,Screw Clips &water proof Insulation Tape etc complete with ISI markNo4725.04725.01.0FalseNoneNoneFalseNoneFalse4725.00
3139255107907None13.31Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets.Rmtr42.042.0180.0FalseNoneNoneFalseNoneFalse7560.00
3139256107907None13.32Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work.No6825.06825.01.0FalseNoneNoneFalseNoneFalse6825.00
3139257107907None13.34Labour charges for erection of outdoor type panel board and meter board units with all necessary materials and labour, tools and equipments including providing cement concrete foundation bed etc., complete as per specification, with testing of as per instructions of engineer incharge of work. Job1522.51522.51.0FalseNoneNoneFalseNoneFalse1522.50
3139258107907None13.38.1Providing and fixing suitable for 1.1 KV class UG cable filled with necessary bitumen/insulating compound complete with terminals, clamps,bolts,nuts and washers etc. with necessary materials and labour tools and equipments as per instructions of engineer incharge of work. 13.38.1 3 1/2 x 6 SqmRmtr393.75393.7525.0FalseNoneNoneFalseNoneFalse9843.750
3139259107907None13.35.2Labour charges for providing connection using insulated sheathed steel wire cable as per IS 1554/ 1988 with latest amendments from KPTCL pole to meter board unit, with all necessary materials ,tools and equipments,as per specificationswith testing of as per instructions of engineer incharge of work. . 13.35.2 3 1/2 x 6 sqmmRmtr168.0168.025.0FalseNoneNoneFalseNoneFalse4200.00
3139260107907None13.36Providing main connection from pole PVC insulated sheathed steel wire cable in new trench as per IS 1554/ 1988 with latest amendments with ISI mark from KPTCL pole to meter board unitRmtr141.75141.7525.0FalseNoneNoneFalseNoneFalse3543.750
3139261107907Noneitem1KKRDB Logo BoardEach6000.06000.01.0FalseNoneNoneFalseNoneFalse6000.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17162054810000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17162054810000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17162054810000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17162054810000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17162054810000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17162054990001NoneNoneELIGIBILITYTo qualify for award of this contract, each Tenderer in its name should have in the last five years i.e., 2019-20, 2020-21,2021-22 ,2022-23 and 2023-24:Tenderer Satisfactorily completed, as prime contractor, at least one similar work such as Construction of Building of value not less than Rs. 16.89 Lakhs/-None
17162055100001NoneNoneELIGIBILITYTo qualify for award of this contract, each Tenderer in its name should have in the last five years i.e., 2019-20, 2020-21 ,2021-22, 2022-23 & 2023-24 a) Achieved in at least two financial years an average financial turnover (in all classes of civil engineering construction works only) of Rs. 33.78 Lakhs- Turn Over certificate must have UDIN Number Otherwise it will not be consideredNone
17162055210000NoneNoneELIGIBILITYThe Tenderer shall furnish, as part of his tender, earnest money deposit in the amount as shown in column 4 of the Table of IFT for this particular work. Tenderer should pay the full EMD amount of Rs. 67,569/- through e-payment onlyNone
17162055340001NoneNoneELIGIBILITYTo qualify for award of this contract, each Tenderer in its name should have in the last five years i.e., 2019-20 ,2020-21 2021-22 ,2022-23 & 2023-24(c) executed in any one year, the following minimum quantities of work (1) EWE: 171.14 cum (2) RRM/BBM: 71.34 cum (3) Plaster: 581.35 Sqm (4) PCC/RCC: 60.95 sqm (5) TMT Steel: 4.1 Tonne (6)Flooring:69.14 SqmNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneProposals for subcontracting components of works amounting to more than 20% of the contract price (for each, the qualifications and experience of the identified sub-contractor in the relevant fields should be attached)NoneNone
NoneNoneNoneNoneTo qualify for award of this contract, each Tenderer in its name should have in the last five years i.e., 2019-20, 2020-21,2021-22 ,2022-23 and 2023-24:Tenderer Satisfactorily completed, as prime contractor, at least one similar work such as Construction of Building of value not less than Rs. 16.89 Lakhs/-Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneTo qualify for award of this contract, each Tenderer in its name should have in the last five years i.e., 2019-20, 2020-21 ,2021-22, 2022-23 & 2023-24 a) Achieved in at least two financial years an average financial turnover (in all classes of civil engineering construction works only) of Rs. 33.78 Lakhs- Turn Over certificate must have UDIN Number Otherwise it will not be consideredFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneITR Filed Copy (Mentioning PAN)
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditors reports for the last five yearsFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneITR Filed Copy (Mentioning PAN)
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Company Registration CertificateTrueTechnical Bid
Less DD/ FDRTrueTechnical Bid
Work done CertificateTrueTechnical Bid
Other DocumentsFalseTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone