tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1710573065000 | 0 | None | None | Buildings | Construction of Auditorium Building to Govt. First grade Degree collage (Balance work) & Rain water Harvesting | 4083782.94 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3119138 | 107166 | None | IN 1.12 PN 8 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools,usage of machinery & other appurtenances required to complete the work.Vol -1 (PWD SR 2023-24 INo.1.12 PN 8) | Cum | 99.75 | 99.75 | 1988.0 | False | None | None | False | None | False | 198303.0 | 0 | 3119139 | 107166 | None | IN 1.14 PN 8 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Vol -1 (PWD SR 2023-24 INo.1.14 PN 8) | Cum | 107.1 | 107.1 | 35.26 | False | None | None | False | None | False | 3776.346 | 0 | 3119140 | 107166 | None | IN 2.1.4 PN 15 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries,curing, and all the other appurtenances required to complete the work as per technical specifications. (M-10)(The cost of steel reinforcement & formwork shall be paid separately) Vol -1 (PWD SR 2023-242 INo.2.1.4 PN 15) | Cum | 6527.85 | 6527.85 | 8.1 | False | None | None | False | None | False | 52875.585 | 0 | 3119141 | 107166 | None | IN 2.1.1 PN 15 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:5:10 Using 40 mm nominal size graded crushed coarse aggregates Vol -1 (PWD SR 2023-242 INo.2.1.1 PN 15) | Cum | 5604.9 | 5604.9 | 149.45 | False | None | None | False | None | False | 837652.305 | 0 | 3119142 | 107166 | None | IN 9.1 PN 59 | Providing and laying Cement concrete flooring 40 mm thick with 20 mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) redoxide finished with a floating coat of neat cement, including cement slurry complete. Vol -2 (PWD SR 2023-242 INo.9.1 PN 59) | Sqm | 473.55 | 473.55 | 528.0 | False | None | None | False | None | False | 250034.4 | 0 | 3119143 | 107166 | None | IN 5.1.1 PN 9 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Vol -2 (PWD SR 2023-24 INo.5.1.1 PN 9) | Cum | 5891.55 | 5891.55 | 14.3 | False | None | None | False | None | False | 84249.165 | 0 | 3119144 | 107166 | None | IN 5.2 PN 9 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Vol -2 (PWD SR 2023-24 INo.5.2 PN 9) | Cum | 6948.9 | 6948.9 | 15.25 | False | None | None | False | None | False | 105970.725 | 0 | 3119145 | 107166 | None | IN 2.3.2 PN 16 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Vol -1 (PWD SR 2023-24 INo.2.3.2 PN 16) | Cum | 6804.0 | 6804.0 | 10.5 | False | None | None | False | None | False | 71442.0 | 0 | 3119146 | 107166 | None | IN 2.3.2 PN 16 | Centering & shuttering charges for column & plinth Beam (8%) | Cum | 544.32 | 544.32 | 10.5 | False | None | None | False | None | False | 5715.36 | 0 | 3119147 | 107166 | None | IN 2.11 PN 18 | Providing Thermo-Mechanically Treated bars of grade Fe-550 or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) Vol -2 (PWD SR 2023-24 INo.2.11 (a) PN 18) | MT | 93929.85 | 93929.85 | 1.58 | False | None | None | False | None | False | 148409.163 | 0 | 3119148 | 107166 | None | IN 1.11 PN 7 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. Vol -1 (PWD SR 2023-24 INo.1.11 PN 7) | Cum | 454.65 | 454.65 | 35.26 | False | None | None | False | None | False | 16030.959 | 0 | 3119149 | 107166 | None | IN 1.8 PN 7 | Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work Vol -1 (PWD SR 2023-24 INo.1.8 PN 7) | Cum | 497.7 | 497.7 | 84.74 | False | None | None | False | None | False | 42175.098 | 0 | 3119150 | 107166 | None | IN 6.8 PN 14 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Vol -2 (PWD SR 2023-24 INo.6.8 PN 14) | Cum | 8367.45 | 8367.45 | 20.22 | False | None | None | False | None | False | 169189.839 | 0 | 3119151 | 107166 | None | IN 8.2.1 PN 41 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Vol -2 (PWD SR 2023-24 INo.8.2.1 PN 41) | Sqm | 309.75 | 309.75 | 553.54 | False | None | None | False | None | False | 171459.015 | 0 | 3119152 | 107166 | None | IN 9.23 PN 63 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Vol -2 (PWD SR 2023-24 INo.9.23 PN 63) | Sqm | 2589.3 | 2589.3 | 45.5 | False | None | None | False | None | False | 117813.15 | 0 | 3119153 | 107166 | None | IN 8.51 PN 50 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Vol -2 (PWD SR 2023-24 INo.8.51 PN 50) | Sqm | 105.0 | 105.0 | 553.54 | False | None | None | False | None | False | 58121.7 | 0 | 3119154 | 107166 | None | IN 12.9 PN 99 | Providing Sal wood frames for false ceiling, partitions etc., main battens of size 50x12.5mm at 600 mm c/c and cross battons 38mmx50mm at 600mm c/c sawn and putup including cost of materials, labour complete as per specifications. Vol -2 (PWD SR 2023-24 INo.12.9 PN 99) | Cum | 104215.65 | 104215.65 | 0.38 | False | None | None | False | None | False | 39601.947 | 0 | 3119155 | 107166 | None | IN 12.15 PN 100 | Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures )Vol -2 (PWD SR 2023-24 INo.12.15 PN 100) | Sqm | 7816.2 | 7816.2 | 8.64 | False | None | None | False | None | False | 67531.968 | 0 | 3119156 | 107166 | None | IN 8.29 PN 45 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Vol -2 (PWD SR 2023-24 INo.8.29 PN 45) | Sqm | 297.15 | 297.15 | 19.44 | False | None | None | False | None | False | 5776.596 | 0 | 3119157 | 107166 | None | IN 43 PN A-13 | Aliminim tower blots (PWD SR 2023-24 INo.43 PN A-13) | No | 63.0 | 63.0 | 6.0 | False | None | None | False | None | False | 378.0 | 0 | 3119158 | 107166 | None | IN 444 PN A-25 | Holds fasts (PWD SR 2023-24 INo.444 PN A-25) | No | 52.5 | 52.5 | 6.0 | False | None | None | False | None | False | 315.0 | 0 | 3119159 | 107166 | None | IN 453 PN A-25 | Hydraulic door closre (PWD SR 2023-24 INo.453 PN A-25) | No | 892.5 | 892.5 | 1.0 | False | None | None | False | None | False | 892.5 | 0 | 3119160 | 107166 | None | IN 230 PN A-18 | Chromium lach and locker (PWD SR 2023-24 INo.230 PN A-18) | No | 892.5 | 892.5 | 1.0 | False | None | None | False | None | False | 892.5 | 0 | 3119161 | 107166 | None | Jem rate | Providing and fixing in position silence Acoustical insulation length 600 millimeterin (jem rate) | Sqm | 1185.0 | 1185.0 | 924.44 | False | None | None | False | None | False | 1095461.4 | 0 | 3119162 | 107166 | None | Jem rate | Supplying and fixing in position unbranded AUDITARIUM char 580 millimeter 590 mm seat with auto tip up mechanism with push back feature (jem rate) | Each | 1599.0 | 1599.0 | 255.0 | False | None | None | False | None | False | 407745.0 | 0 | 3119163 | 107166 | None | IN 11.31 PN 86 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-Incharge including cost of materials, labour, usage charges of machinery complete as per specifications.Vol -2 ( SR 2023-24 INo.11.31 PN 86) | Sqm | 120.75 | 120.75 | 32.4 | False | None | None | False | None | False | 3912.3 | 0 | 3119164 | 107166 | None | IN 16.8 PN 191 | Constructing brick masonry chamber of internal dimension 600x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover Vol -5 (PWD SR 2023-24 INo.IN 16.8 PN 191) | Each | 4592.7 | 4592.7 | 6.0 | False | None | None | False | None | False | 27556.2 | 0 | 3119165 | 107166 | None | IN 11.30.1 PN 85 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes including cost of materials, labour, usage charges of machinery complete, as per directions of the Engineer-in-Charge.Vol -2(PWD SR 23-24 INo.11.30.1 PN 85) | Sqm | 957.6 | 957.6 | 2.16 | False | None | None | False | None | False | 2068.416 | 0 | 3119166 | 107166 | None | IN 1.6.1 PN 6 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. 1.6.1 In all kinds of soils. Depth upto 1.50m Vol -1 (PWD SR 23-24 INo.1.6.1 PN 6) | Cum | 508.2 | 508.2 | 30.0 | False | None | None | False | None | False | 15246.0 | 0 | 3119167 | 107166 | None | IN 10.1.7 PN 113 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete Vol -5 (PWD SR 23-24 INo.10.1.7 PN 113) | Rmtr | 431.55 | 431.55 | 150.0 | False | None | None | False | None | False | 64732.5 | 0 | 3119168 | 107166 | None | IN 17.1 PN 175 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge Vol -2 (PWD SR 23-24 INo.17.1 PN 175) | Cum | 1052.1 | 1052.1 | 12.0 | False | None | None | False | None | False | 12625.2 | 0 | 3119169 | 107166 | None | IN 17.6.1 PN 175 | Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270,of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge. Vol -2 (PWD SR 23-24 INo.17.6.1 PN 175) 100 mm nominal size dia having minimum wall thickness 5.00 mm Vol -2 (PWD SR 23-24 INo.17.6.1 PN 175) | Rmtr | 1121.4 | 1121.4 | 5.0 | False | None | None | False | None | False | 5607.0 | 0 | 3119170 | 107166 | None | IN 17.11.1 PN 176 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I) 100 mm dia Vol -2 (PWD SR 23-24 INo.17.11.1 PN 176) | Each | 222.6 | 222.6 | 1.0 | False | None | None | False | None | False | 222.6 | 0 |
| 1710573065000 | 0 | None | None | Buildings | Electrical works | 1052607.91 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3119171 | 107167 | None | IN 1.2.2 PN 2 | Supplying heavy gauge PVC conduit pipe .2. mm dia.25.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary | Rmtr | 81.9 | 81.9 | 300.0 | False | None | None | False | None | False | 24570.0 | 0 | 3119172 | 107167 | None | IN 1.7.1 PN 2 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complup to 50 mm ete. | Rmtr | 30.45 | 30.45 | 200.0 | False | None | None | False | None | False | 6090.0 | 0 | 3119173 | 107167 | None | IN 2.1.1 PN 5 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet. short point up to 3 mtr from tapping point out let via switch GROUP | Each | 299.25 | 299.25 | 10.0 | False | None | None | False | None | False | 2992.5 | 0 | 3119174 | 107167 | None | IN 2.1.2 PN 5 | Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch | Each | 413.7 | 413.7 | 15.0 | False | None | None | False | None | False | 6205.5 | 0 | 3119175 | 107167 | None | IN 2.1.3PN 5 | long above 6 mtr up to 10 mtr from tapping point to out let via switch | Each | 532.35 | 532.35 | 14.0 | False | None | None | False | None | False | 7452.9 | 0 | 3119176 | 107167 | None | IN 3.1.2 PN 8 | Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 | Each | 154.35 | 154.35 | 45.0 | False | None | None | False | None | False | 6945.75 | 0 | 3119177 | 107167 | None | IN 3.4.6 PN 8 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12 way | Each | 334.95 | 334.95 | 14.0 | False | None | None | False | None | False | 4689.3 | 0 | 3119178 | 107167 | None | IN 3.4.3 PN 8 | Supplying and flush mounting powder coated / galvanized metal box 4-5 way | Each | 185.85 | 185.85 | 25.0 | False | None | None | False | None | False | 4646.25 | 0 | 3119179 | 107167 | None | IN 3.3.5 PN 8 | Supplying and flush mounting powder coated / galvanized metal box 8 way | Each | 229.95 | 229.95 | 6.0 | False | None | None | False | None | False | 1379.7 | 0 | 3119180 | 107167 | None | IN 3.5.3 PN 5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 modular | Each | 183.75 | 183.75 | 20.0 | False | None | None | False | None | False | 3675.0 | 0 | 3119181 | 107167 | None | IN 3.5.5 PN 8 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 module | Each | 298.2 | 298.2 | 6.0 | False | None | None | False | None | False | 1789.2 | 0 | 3119182 | 107167 | None | IN 3.5.6 PN 8 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 12 module | Each | 361.2 | 361.2 | 12.0 | False | None | None | False | None | False | 4334.4 | 0 | 3119183 | 107167 | None | IN 5.19.11 PN 18 | Supplying and fixing regular MCCB distribution Panel confirming to IS 8828, on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440Volts 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity 4 Way TP & N | Each | 4239.9 | 4239.9 | 5.0 | False | None | None | False | None | False | 21199.5 | 0 | 3119184 | 107167 | None | IN 5.18.1 PN 17 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. | Each | 435.75 | 435.75 | 12.0 | False | None | None | False | None | False | 5229.0 | 0 | 3119185 | 107167 | None | IN 5.18.8 PN 17 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.40A TPN | Each | 3196.2 | 3196.2 | 4.0 | False | None | None | False | None | False | 12784.8 | 0 | 3119186 | 107167 | None | IN 2.3.3 PN 5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming latest amanment 2.5SQMM | Rmtr | 44.1 | 44.1 | 500.0 | False | None | None | False | None | False | 22050.0 | 0 | 3119187 | 107167 | None | IN 2.3.4 PN 5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming latest amanment 4 Sqmm | Rmtr | 66.15 | 66.15 | 200.0 | False | None | None | False | None | False | 13230.0 | 0 | 3119188 | 107167 | None | IN 2.3.5 PN 5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming latest amanment 6Sqmm | Rmtr | 96.6 | 96.6 | 120.0 | False | None | None | False | None | False | 11592.0 | 0 | 3119189 | 107167 | None | Jem rate | Supplying of Ceiling Fan with Capacitor rating As per BAJAJ Aluminium wall Fan 2 year warranty (superme plus air circulator 750 mm wall) in jem rate | Each | 7000.0 | 7000.0 | 16.0 | False | None | None | False | None | False | 112000.0 | 0 | 3119190 | 107167 | None | IN 13.11 PN 57 | Fixing a ceiling/ wall mounting fan of a ll capacities and all types, with necessary clamps and 'S' hook made out of 15 mm dia MS rod, with 5A. ceiling rose of approved quality with necessary length of 23/ 0.00 76 inch PVC insulated twint wisted wire of approved quality,mounted on a suitable size wooden board and wired | Each | 330.75 | 330.75 | 16.0 | False | None | None | False | None | False | 5292.0 | 0 | 3119191 | 107167 | None | IN 11.9.1 PN 46 | Supply of LED flood light luminaire with pressure diecast aluminium housing body foroptimal thermal dissipation. Lamp com partment comprising of antiglare clear diffuser with Injection moulded polycar bonate/clear glass material, delivering superior light output Rated life Burning Hrs50000 hr@ Lumen Maintenance of70%, CCT ,IP66o ptical and electrical compartment & impactresistance of complete | Each | 7106.4 | 7106.4 | 10.0 | False | None | None | False | None | False | 71064.0 | 0 | 3119192 | 107167 | None | IN 13.19 PN 58 | Fixingall types and all capacities of 1'x4'/2'x2'LED Light fitting s indoor on the wall/ ceiling/ rafters/ girders with necessary supporting frame, using 2310.0076"twin twisted PVC insulated wires, required Nos of round blocks and clamps | Each | 514.5 | 514.5 | 25.0 | False | None | None | False | None | False | 12862.5 | 0 | 3119193 | 107167 | None | IN 11.8.2 PN 45 | Supply of LED Street light luminaire with pressure diecast aluminium housing body for optimal thermal dissipation. Lamp compart ment comprising of anti glare clear diffuser with Injection moulded polycar bonate material, delivering superior light output Ratedli fe Burning Hrs 50000hr LED street light 40 W | Each | 4225.2 | 4225.2 | 6.0 | False | None | None | False | None | False | 25351.2 | 0 | 3119194 | 107167 | None | IN 11.5.3 PN 44 | Supply of round /square recess/ surface mounted rolling type LED Down light with.WGU10 LED Lamp Rib Fabricated from die cast aluminium with whit e powder coat edp rewired to main sconnector & hasswive llinguni to faluminiumdie casteye ball & LED Lam p positionre tained by circular wire spring, with Life of 25000 burning hours&70%lumenmain tenance with . PowerIn put: 220-240V @50 /60 Hz & Power factor g with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round dwon light 15-18 W | Each | 1390.2 | 1390.2 | 15.0 | False | None | None | False | None | False | 20853.0 | 0 | 3119195 | 107167 | None | IN 5.11.1 PN 15 | Fixing all types and all capacities of fluorescent/ falseceiling/ spotlight/CFL /LED fittings indoor on the wall/ ceiling/ rafters/ girders using 23/0. 0076 "twin twisted PVC insulated wires, required Nos of round blocks and clamps125 A | Each | 5754.0 | 5754.0 | 1.0 | False | None | None | False | None | False | 5754.0 | 0 | 3119196 | 107167 | None | IN 13.7 PN 56 | Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessoris (Smenclosure sheet metal Excution )125 A | Each | 128.1 | 128.1 | 8.0 | False | None | None | False | None | False | 1024.8 | 0 | 3119197 | 107167 | None | IN 5.40.1 PN 20 | Supplying .200. amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.100 Amps 4x30 x 6 mm Aluminum Strips | Rmtr | 2588.25 | 2588.25 | 3.0 | False | None | None | False | None | False | 7764.75 | 0 | 3119198 | 107167 | None | ESCOM SR PN 13 of 81 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LT UG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 35 sqmm | Km | 161765.1 | 161765.1 | 0.05 | False | None | None | False | None | False | 8088.255 | 0 | 3119199 | 107167 | None | IN 5.42.3 PN20 | Fabricating supplying and mounting MS box made out SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.18 SWG | Sq CM | 0.4 | 0.4 | 74090.0 | False | None | None | False | None | False | 29636.0 | 0 | 3119200 | 107167 | None | IN 9.32 PN 38 | Supplying, erecting, testing & commissioning of ON LINEUPS system suitable foroperationon 230V, 50Hz,A/Csupply, withi solationtrans former all accessories complete and Excluding batteries and wiring complete. 5 KVA on line | Each | 71802.15 | 71802.15 | 2.0 | False | None | None | False | None | False | 143604.3 | 0 | 3119201 | 107167 | None | IN 12.60.5 PN 55 | Supplying & Fixing Chemical earthling for grounding .Conduits,ICcut-outs & other equipments backfill compound whichisnon-corrosive,thermally conductive,potential topermissiblelimits,superior Faultconduction capacity, nontoxic,weather resistance & capable of achieving ohmic value less than one ohm 1 KIT | Each | 4754.4 | 4754.4 | 3.0 | False | None | None | False | None | False | 14263.2 | 0 | 3119202 | 107167 | None | Jem rate | Supplying, erecting, testing & commissioning Sony Horizontal profile projector 600 millimeter 20x24 monh (VW360ES 3600 lumens) jem rate | Each | 59300.0 | 59300.0 | 1.0 | False | None | None | False | None | False | 59300.0 | 0 | 3119203 | 107167 | None | IN 5.15.1 PN17 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.100 amps 25 Ka | Each | 6390.3 | 6390.3 | 1.0 | False | None | None | False | None | False | 6390.3 | 0 | 3119204 | 107167 | None | IN 6.2.1 PN 30 | Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete.12' sweep (300mm) | Each | 3117.45 | 3117.45 | 16.0 | False | None | None | False | None | False | 49879.2 | 0 | 3119205 | 107167 | None | IN 13.14 PN 57 | Fixing one exhaust fan inthenitchal ready leftint hewall with bolts and nuts and 5A. ceiling rose with sufficient lengthof23/0.0076inch PVC insulated twin core wire. | Each | 516.6 | 516.6 | 16.0 | False | None | None | False | None | False | 8265.6 | 0 | 3119206 | 107167 | None | Jem rate | Supplying, erecting, Arrow sign projector sreen 120 inches Arrow sign (120" inch self lock projector screen) jem rate | Each | 3600.0 | 3600.0 | 1.0 | False | None | None | False | None | False | 3600.0 | 0 | 3119207 | 107167 | None | Jem rate | Supplying and installing Get semi rugged Note book Lop top intel Core i5 -1135G7 in Jem rate | Each | 190000.0 | 190000.0 | 1.0 | False | None | None | False | None | False | 190000.0 | 0 | 3119208 | 107167 | None | IN 9.4.6 PN 38 | Supplying, installation, testing & commissioning of 12 V DC,Ahbatteries in polypro pylenecontainer for U.P.S. Sealed maintenance free batteries. | Each | 16689.75 | 16689.75 | 4.0 | False | None | None | False | None | False | 66759.0 | 0 | 3119209 | 107167 | None | GSCOM | GESCOM Deposit for and fixing meter and GESCOM service charges | Unit | 50000.0 | 50000.0 | 1.0 | False | None | None | False | None | False | 50000.0 | 0 |
| 1710573065000 | 0 | None | None | Buildings | Auditorium Truss | 3096177.7 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3119210 | 107168 | None | IN 1.16.2 PN 82 | Providing and fixing Structural Steel work riveted, bolted or welded in built up
sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. P.No.82 I.No.1.16.2 of PWD S.R 2023-24 VOL 2 (Bottom chord member 100x100x6mm) | Kgs | 154.35 | 154.35 | 4238.67 | False | None | None | False | None | False | 654238.7145 | 0 | 3119211 | 107168 | None | IN 1.16.2 PN 82 | Providing and fixing Structural Steel work riveted, bolted or welded in built up
sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. P.No.82 I.No.1.16.2 of PWD S.R 2023-24 VOL 2 (Top chord Member 100x100x6mm) | Kgs | 154.35 | 154.35 | 4176.95 | False | None | None | False | None | False | 644712.2325 | 0 | 3119212 | 107168 | None | IN 1.16.2 PN 82 | Providing and fixing Structural Steel work riveted, bolted or welded in built up
sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. P.No.82 I.No.1.16.2 of PWD S.R 2023-24 VOL 2 (Internal member 75x75x6mm ) | Kgs | 154.35 | 154.35 | 2242.37 | False | None | None | False | None | False | 346109.8095 | 0 | 3119213 | 107168 | None | IN 1.16.2 PN 82 | Providing and fixing Structural Steel work riveted, bolted or welded in built up
sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. P.No.82 I.No.1.16.2 of PWD S.R 2023-24 VOL 2 (purlins 75x50x6 mm) | Kgs | 154.35 | 154.35 | 909.12 | False | None | None | False | None | False | 140322.672 | 0 | 3119214 | 107168 | None | IN 1.16.2 PN 82 | Providing and fixing Structural Steel work riveted, bolted or welded in built up
sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. P.No.82 I.No.1.16.2 of PWD S.R 2023-24 VOL 2 (Base plate (0.40x0.40m) 25mm top and bottom plate) | Kgs | 154.35 | 154.35 | 942.0 | False | None | None | False | None | False | 145397.7 | 0 | 3119215 | 107168 | None | IN 1.16.2 PN 82 | Providing and fixing Structural Steel work riveted, bolted or welded in built up
sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. P.No.82 I.No.1.16.2 of PWD S.R 2023-24 VOL 2 (Cleat angles (100x100mm) top and bottom plates ) | Kgs | 154.35 | 154.35 | 276.0 | False | None | None | False | None | False | 42600.6 | 0 | 3119216 | 107168 | None | IN 1.16.2 PN 82 | Providing and fixing Structural Steel work riveted, bolted or welded in built up
sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. P.No.82 I.No.1.16.2 of PWD S.R 2023-24 VOL 2 (Door 10 No 20mm bolts 750mm) | Kgs | 154.35 | 154.35 | 292.5 | False | None | None | False | None | False | 45147.375 | 0 | 3119217 | 107168 | None | IN 7.38 PN 26 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coatedthickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid
scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin- charge. The sheet shall be fixed using self drilling/self
tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required P.No.26 I.No.7.38 of PWD S.R 2023-24 VOL 2 (Rectangular area) | Sqm | 596.4 | 596.4 | 729.0 | False | None | None | False | None | False | 434775.6 | 0 | 3119218 | 107168 | None | IN 7.48 PN 30 | Providing & fixing false ceiling at all height including providing & fixing of framework made of special section, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/ m2 (both side inclusive) as per IS : 277 and consisting of angle cleat of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm c/c, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x10 x0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I chanels 45 x15 x 0.90mm running at the spacing of 1200 mm c/c, ntermediate channel with connecting clip made out of 2.64mm dia x230mm long G.I wire at every junction, including fixing perimeter channels 0.50mm thick 27mm high having flanges of 20mm and 30mm long, the erimeter of ceiling fixed to wall/ partitions with the help of Rawl plugs at 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of Calcium Silicate Board to ceiling section and perimeter 8 mm thick Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process P.No.30 I.No.7.48 of PWD S.R 2023-24 VOL 2 | Sqm | 1270.5 | 1270.5 | 506.0 | False | None | None | False | None | False | 642873.0 | 0 |
| 1710573065000 | 0 | None | None | Buildings | Pavement | 1136956.65 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3119219 | 107169 | None | IN 1.14 PN 8 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Vol -1 (PWD SR 2023-24 INo.1.14 PN 8) | Cum | 107.1 | 107.1 | 5.4 | False | None | None | False | None | False | 578.34 | 0 | 3119220 | 107169 | None | IN 2.1.4 PN 15 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries,curing, and all the other appurtenances required to complete the work as per technical specifications. (M-10)(The cost of steel reinforcement & formwork shall be paid separately)Vol -1 (PWD SR 2023-24 INo.2.1.4 PN 15) | Cum | 6527.85 | 6527.85 | 48.6 | False | None | None | False | None | False | 317253.51 | 0 | 3119221 | 107169 | None | IN 2.3.1 PN 16 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Vol -1 (PWD SR 2023-24 INo.2.3.1 PN 16) | Cum | 6639.15 | 6639.15 | 8.4 | False | None | None | False | None | False | 55768.86 | 0 | 3119222 | 107169 | None | IN 2.3.1 PN 16 | Centering & shuttering charges for support wall (8%) | Cum | 557.89 | 557.89 | 8.4 | False | None | None | False | None | False | 4686.276 | 0 | 3119223 | 107169 | None | IN 2.11(a) PN 18 | Providing Thermo-Mechanically Treated bars of grade Fe-550 or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) Vol -2 (PWD SR 2023-24 INo.2.11 (a) PN 18) | MT | 93929.85 | 93929.85 | 0.29 | False | None | None | False | None | False | 27239.6565 | 0 | 3119224 | 107169 | None | IN 6.8.2 PN 51 | Providing and laying 80mm thick factory made precast M -30 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Commercial Traffic Axle load repetitions upto 10MSA & for Residential Streets of approved shape and colour, laid in required pattern and including over 40mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (WMM/WBM Base to be paid separately as per relevant technical specification)Vol -3 (PWD SR 2023-24 INo.6.8.2 PN 51) | Sqm | 1219.05 | 1219.05 | 600.0 | False | None | None | False | None | False | 731430.0 | 0 |
|
|
---|