3170980 | 109175 | None | 2.5.1 V-I | Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all lead and lifts as per direction Engineering in Charge of the work | Cum | 11952.9 | 11952.9 | 11.27 | False | None | None | False | None | False | 134709.183 | 0 |
3170981 | 109175 | None | 2.5.1 V-I | Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all lead and lifts as per direction Engineering in Charge of the work | Cum | 11249.78 | 11249.78 | 5.79 | False | None | None | False | None | False | 65136.2262 | 0 |
3170982 | 109175 | None | 2.5.1 V-I | Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all lead and lifts as per direction Engineering in Charge of the work | Cum | 10195.12 | 10195.12 | 0.61 | False | None | None | False | None | False | 6219.0232 | 0 |
3170983 | 109175 | None | 2.5.1 V-I | Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all lead and lifts as per direction Engineering in Charge of the work | Cum | 10546.67 | 10546.67 | 3.3 | False | None | None | False | None | False | 34804.011 | 0 |
3170984 | 109175 | None | 2.5.1 V-I | Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all lead and lifts as per direction Engineering in Charge of the work | Cum | 11249.78 | 11249.78 | 26.13 | False | None | None | False | None | False | 293956.7514 | 0 |
3170985 | 109175 | None | 2.5.1 V-I | Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all lead and lifts as per direction Engineering in Charge of the work | Cum | 10546.67 | 10546.67 | 79.21 | False | None | None | False | None | False | 835401.7307 | 0 |
3170986 | 109175 | None | 6.8 V-I | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. with all lead and lifts as per direction Engineering in Charge of the work with all lead and lifts as per direction Engineering in Charge of the work | Cum | 8451.12 | 8451.12 | 74.22 | False | None | None | False | None | False | 627242.1264 | 0 |
3170987 | 109175 | None | 8.2.1 V-II | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. with all lead and lifts as per direction Engineering in Charge of the work | Sqm | 312.7 | 312.7 | 735.84 | False | None | None | False | None | False | 230097.168 | 0 |
3170988 | 109175 | None | 8.3.1 V-II | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 375.24 | 375.24 | 298.96 | False | None | None | False | None | False | 112181.7504 | 0 |
3170989 | 109175 | None | 8.33.1 V-II | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 167.48 | 167.48 | 735.84 | False | None | None | False | None | False | 123238.4832 | 0 |
3170990 | 109175 | None | 8.30 V-II | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR 2023-24, Vol 2, P.No 46, I. No 8.30) | Sqm | 184.53 | 184.53 | 479.3 | False | None | None | False | None | False | 88445.229 | 0 |
3170991 | 109175 | None | 9.23 V-II | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Polished granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. | Sqm | 2615.19 | 2615.19 | 519.74 | False | None | None | False | None | False | 1359218.8506 | 0 |
3170992 | 109175 | None | 9.31 V-II | Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. | Sqm | 2211.14 | 2211.14 | 49.1 | False | None | None | False | None | False | 108566.974 | 0 |
3170993 | 109175 | None | 10.14 V-II | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg/m2, including pointing in white cement mixed with pigment of matching shade complete. | Sqm | 1172.91 | 1172.91 | 57.79 | False | None | None | False | None | False | 67782.4689 | 0 |
3170994 | 109175 | None | 12.92 V-II | Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL9016) sections and with minimum Titanium
Dioxide) at 6PHR with TPV Thermo Plastic Vulcanized) and lead free with gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D 3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 00mm x 2400mm | Sqm | 6622.82 | 6622.82 | 10.08 | False | None | None | False | None | False | 66758.0256 | 0 |
3170995 | 109175 | None | 2.11a V-I | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. | Tonne | 94869.15 | 94869.15 | 12.24 | False | None | None | False | None | False | 1161198.396 | 0 |
3170996 | 109175 | None | 12.84 V-II | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm | Sqm | 5225.43 | 5225.43 | 28.8 | False | None | None | False | None | False | 150492.384 | 0 |
3170997 | 109175 | None | 11.34a V-II | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. with all lead and lifts as per direction Engineering in Charge of the work | Kg | 178.16 | 178.16 | 2146.16 | False | None | None | False | None | False | 382359.8656 | 0 |
3170998 | 109175 | None | 11.5.1 V-II | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 4748.92 | 4748.92 | 25.2 | False | None | None | False | None | False | 119672.784 | 0 |
3170999 | 109175 | None | 8.33.3 V-II | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 147.41 | 147.41 | 152.6 | False | None | None | False | None | False | 22494.766 | 0 |
3171000 | 109175 | None | 15.1 V-II | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. | Sqm | 866.43 | 866.43 | 528.08 | False | None | None | False | None | False | 457544.3544 | 0 |
3171001 | 109175 | None | 10.1.6 V-v | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into
trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For:PVC pipes 90mm dia., 6 kg/sqcm & class 3 | MT | 295.05 | 295.05 | 60.0 | False | None | None | False | None | False | 17703.0 | 0 |
3171002 | 109175 | None | 11.28 V-II | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 599.18 | 599.18 | 11.52 | False | None | None | False | None | False | 6902.5536 | 0 |
3171003 | 109175 | None | 1.6 V-V | Painting (one coats) with black Japan paint of approved brand and manufacture to give an even shade. including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter , costof materials, labour complete as per specifications and as per directionsof Engineer-in-charge | Sqm | 72.11 | 72.11 | 80.0 | False | None | None | False | None | False | 5768.8 | 0 |
3171004 | 109175 | None | 14.5.1 V-II | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :Single half stall urinal with 5 litre P.V.C. automatic flushing cistern | Each | 9164.84 | 9164.84 | 2.0 | False | None | None | False | None | False | 18329.68 | 0 |
3171005 | 109175 | None | 14.3.1 V-II | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid | Each | 6338.61 | 6338.61 | 2.0 | False | None | None | False | None | False | 12677.22 | 0 |
3171006 | 109175 | None | 14.7.3 V-II | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps | Each | 3039.39 | 3039.39 | 2.0 | False | None | None | False | None | False | 6078.78 | 0 |
3171007 | 109175 | None | 13.34 V-II | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. | l | 9.54 | 9.54 | 500.0 | False | None | None | False | None | False | 4770.0 | 0 |
3171008 | 109175 | None | 13.50.3 V-II | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 25 mm nominal dia Pipes | Mtr | 237.55 | 237.55 | 50.0 | False | None | None | False | None | False | 11877.5 | 0 |
3171009 | 109175 | None | 13.54 V-II | Constructing brick masonry chamber for underground C.I. inspectionchamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 500X700 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets :With common burnt clay (non modular) bricks of class designation 3.5 | Nos | 6657.82 | 6657.82 | 2.0 | False | None | None | False | None | False | 13315.64 | 0 |
3171010 | 109175 | None | 13.58 V-II | Providing and fixing PVC (S.W.R) Gully Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete | Nos | 366.93 | 366.93 | 4.0 | False | None | None | False | None | False | 1467.72 | 0 |
3171011 | 109175 | None | 13.13 V-II | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 g. | Nos | 897.18 | 897.18 | 4.0 | False | None | None | False | None | False | 3588.72 | 0 |
3171012 | 109175 | None | 13.50.10 V-II | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittingsThis includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 150 mm nominal dia Pipes | Nos | 1689.38 | 1689.38 | 30.0 | False | None | None | False | None | False | 50681.4 | 0 |
3171013 | 109175 | None | 8.80 V-II | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groovecomplete as per specifications and direction of the Engineer-in-charge:20 mm to 25 mm wide to required depth. | Mtr | 69.99 | 69.99 | 50.0 | False | None | None | False | None | False | 3499.5 | 0 |
3171014 | 109175 | None | 1.3.2 PWD ELE V-VI | Supplying heavy gauge PVC Conduit piipe.... dia....mm thick with suitable size bends, metal junction boxes adhesive paste etc. by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19mm dia 2mm thick | Rmtr | 68.0 | 68.0 | 300.0 | False | None | None | False | None | False | 20400.0 | 0 |
3171015 | 109175 | None | 1.3.2 PWD ELE V-VI | Supplying heavy gauge PVC Conduit piipe.... dia....mm thick with suitable size bends, metal junction boxes adhesive paste etc. by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25mm dia 2mm thick | Rmtr | 79.0 | 79.0 | 150.0 | False | None | None | False | None | False | 11850.0 | 0 |
3171016 | 109175 | None | 1.7.1 PWD ELE V-VI | Groove cutting Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of conduit/GI pipe and plastering, finishing upto wall surface complete.Upto 50mm conduit | Rmtr | 29.0 | 29.0 | 450.0 | False | None | None | False | None | False | 13050.0 | 0 |
3171017 | 109175 | None | 1.4 PWD ELE V-VI | Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.135*75*65 | Each | 139.0 | 139.0 | 30.0 | False | None | None | False | None | False | 4170.0 | 0 |
3171018 | 109175 | None | 1.4 PWD ELE V-VI | Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.200*200*65 | Each | 348.0 | 348.0 | 30.0 | False | None | None | False | None | False | 10440.0 | 0 |
3171019 | 109175 | None | 1.5 PWD ELE V-VI | Supplying and fixing PVC/metal conduit Deep junction box 19/20mm deep junction box | Each | 49.0 | 49.0 | 35.0 | False | None | None | False | None | False | 1715.0 | 0 |
3171020 | 109175 | None | 1.5 PWD ELE V-VI | Supplying and fixing PVC/metal conduit Deep junction box 25mm deep junction box | Each | 56.0 | 56.0 | 35.0 | False | None | None | False | None | False | 1960.0 | 0 |
3171021 | 109175 | None | 1.10 PWD ELE V-VI | Supplying and fixing "S' Hook made out of 14mm dia MS Rod | Nos | 52.0 | 52.0 | 12.0 | False | None | None | False | None | False | 624.0 | 0 |
3171022 | 109175 | None | 2.1.1 PWD ELE V-VI | Point wiring using Copper wire with switch : Supplying and wiring adopting loop system in existing PVC conduit /casing capping using 2x1.5sqmm (Phase and neutral) and 1x1.00sqmm (Earth wire0 FRLS multistrand PVC insulated copper wire (confirming to IS-694 : and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet (a) Short point upto 3mtr from tapping point to outlet via switch | Point | 285.0 | 285.0 | 360.0 | False | None | None | False | None | False | 102600.0 | 0 |
3171023 | 109175 | None | 3.5.1 PWD ELE V-VI | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 1-2 Module | Each | 137.0 | 137.0 | 22.0 | False | None | None | False | None | False | 3014.0 | 0 |
3171024 | 109175 | None | 3.5.1 PWD ELE V-VI | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 6 Module | Each | 234.0 | 234.0 | 12.0 | False | None | None | False | None | False | 2808.0 | 0 |
3171025 | 109175 | None | 3.4 PWD ELE V-VI | Supplying and flush mounting powder coated/galvnized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/CC wall 1-2 Way | Each | 138.0 | 138.0 | 22.0 | False | None | None | False | None | False | 3036.0 | 0 |
3171026 | 109175 | None | 3.4 PWD ELE V-VI | Supplying and flush mounting powder coated/galvnized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/CC wall 6 Way | Each | 220.0 | 220.0 | 12.0 | False | None | None | False | None | False | 2640.0 | 0 |
3171027 | 109175 | None | 3.6.1 PWD ELE V-VI | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps one way | Each | 102.0 | 102.0 | 22.0 | False | None | None | False | None | False | 2244.0 | 0 |
3171028 | 109175 | None | 3.6.1 PWD ELE V-VI | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps Two way | Each | 166.0 | 166.0 | 12.0 | False | None | None | False | None | False | 1992.0 | 0 |
3171029 | 109175 | None | 3.6.1 PWD ELE V-VI | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293 Stepped Fan | Each | 357.0 | 357.0 | 10.0 | False | None | None | False | None | False | 3570.0 | 0 |
3171030 | 109175 | None | 3.6.1 PWD ELE V-VI | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293 TV/Telephone | Each | 156.0 | 156.0 | 5.0 | False | None | None | False | None | False | 780.0 | 0 |
3171031 | 109175 | None | 3.7 PWD ELE V-VI | Supplying and fixing 32Amps security and energy saving DP switch with key tag suitable to operate on 230 volts. 50Hz AC supply and completely wired on existing box | Each | 646.0 | 646.0 | 6.0 | False | None | None | False | None | False | 3876.0 | 0 |
3171032 | 109175 | None | 3.12 PWD ELE V-VI | Supplying way plastic gang box and fixing using necessary wooden/rawl/phill plugs and screws 1 way gang box | Each | 23.0 | 23.0 | 16.0 | False | None | None | False | None | False | 368.0 | 0 |
3171033 | 109175 | None | 3.12 PWD ELE V-VI | Supplying way plastic gang box and fixing using necessary wooden/rawl/phill plugs and screws 2 to 4 way gang box | Each | 32.0 | 32.0 | 15.0 | False | None | None | False | None | False | 480.0 | 0 |
3171034 | 109175 | None | 3.14 PWD ELE V-VI | Supplying and fixing /replacing of 6/16/32Amps electrical accessories on existing switch board. 6 Amps | Each | 70.0 | 70.0 | 20.0 | False | None | None | False | None | False | 1400.0 | 0 |
3171035 | 109175 | None | 5.4.1 PWD ELE V-VI | Fixing a Shunt capacitor of ….KVAR capacity with necessary clamps, bolts and nuts on existing wooden or metal board including banking of more than one capacitor | Each | 154.0 | 154.0 | 30.0 | False | None | None | False | None | False | 4620.0 | 0 |
3171036 | 109175 | None | 2.3.1 PWD ELE V-VI | Wiring for lighting /power circuit using one of PVC insulated 1100V Grade ,muftis and copper conductor single core cable in open or concealed system of wiring. Using class ‘A’ approved materialals. 1Sqmm 1Sqmm | Mtr | 19.0 | 19.0 | 70.0 | False | None | None | False | None | False | 1330.0 | 0 |
3171037 | 109175 | None | 2.3.1 PWD ELE V-VI | Wiring for lighting /power circuit using one of PVC insulated 1100V Grade ,muftis and copper conductor single core cable in open or concealed system of wiring. Using class ‘A’ approved materialals. 1Sqmm 2.5Sqmm | Mtr | 42.0 | 42.0 | 135.0 | False | None | None | False | None | False | 5670.0 | 0 |
3171038 | 109175 | None | 5.6.6 PWD ELE V-VI | Supplying and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws. 20"x20"x2.5" | Each | 326.13 | 326.13 | 14.0 | False | None | None | False | None | False | 4565.82 | 0 |
3171039 | 109175 | None | 5.7.1 PWD ELE V-VI | Supplying and fixing of porcelain fuse channel with cut out on existing wooden/panel using necessary nuts.bolts and washers 16Amps | Each | 157.0 | 157.0 | 12.0 | False | None | None | False | None | False | 1884.0 | 0 |
3171040 | 109175 | None | 5.18.1 PWD ELE V-VI | Supplying and fixing regular MCB distribution boards on wall/wood board/flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCBs single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure 4 way SP and N | Each | 1241.0 | 1241.0 | 6.0 | False | None | None | False | None | False | 7446.0 | 0 |
3171041 | 109175 | None | 6.3.1 PWD ELE V-VI | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. single phase AC supply conforming to ISS-374-1979 and with double ball bearing system48" Sweep (1200 mm) Regular model (1200mm) Regular Model | Each | 2984.0 | 2984.0 | 10.0 | False | None | None | False | None | False | 29840.0 | 0 |
3171042 | 109175 | None | 32.03 PWD ELE V-VI | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm (P- 9, INo.-32.03) | Km | 141842.0 | 141842.0 | 0.05 | False | None | None | False | None | False | 7092.1 | 0 |
3171043 | 109175 | None | 11.3.1 PWD ELE V-VI | Supplying of LED light fighting 1x2'-9/10w.feet-PVC batten with integrated LED tube ..... W with high quality diffuser with life of 25000 burning hours and 70 lumen maintenance with CRI 80. Power input 220-240v 50/60Hz and power factor 0.9 along with CE approved 2 years warranty against any maufacturing defect working under standard electrical condition | Each | 551.0 | 551.0 | 30.0 | False | None | None | False | None | False | 16530.0 | 0 |
3171044 | 109175 | None | 1.12.1 V-I | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavatedearth or sorting & stacking the selected earth for reuse in a radiusof 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. | Cum | 99.75 | 99.75 | 21.45 | False | None | None | False | None | False | 2139.6375 | 0 |
3171045 | 109175 | None | 1.15.1 V-I | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m with all lead and lifts as per direction Engineering in Charge of the work | Cum | 381.15 | 381.15 | 137.8 | False | None | None | False | None | False | 52522.47 | 0 |
3171046 | 109175 | None | 4.1 V-II | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. with all lead and lifts as per direction Engineering in Charge of the work | Sqm | 123.9 | 123.9 | 210.54 | False | None | None | False | None | False | 26085.906 | 0 |
3171047 | 109175 | None | 2.1.3 V-1 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6288.45 | 6288.45 | 23.04 | False | None | None | False | None | False | 144885.888 | 0 |
3171048 | 109175 | None | 5.4 V-II | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 22.4 | False | None | None | False | None | False | 150269.28 | 0 |
3171049 | 109175 | None | 1.9 V-I | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. with all lead and lifts as per direction Engineering in Charge of the work | Cum | 279.3 | 279.3 | 284.03 | False | None | None | False | None | False | 79329.579 | 0 |
3171050 | 109175 | None | 1.11 V-I | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. with all lead and lifts as per direction Engineering in Charge of the work | Cum | 454.65 | 454.65 | 124.78 | False | None | None | False | None | False | 56731.227 | 0 |
3171051 | 109175 | None | 2.2.1 V-I | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7129.46 | 7129.46 | 23.33 | False | None | None | False | None | False | 166330.3018 | 0 |
3171052 | 109175 | None | 2.4.2 V-I | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6639.15 | 6639.15 | 2.39 | False | None | None | False | None | False | 15867.5685 | 0 |
3171053 | 109175 | None | 2.4.2 V-I | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11286.56 | 11286.56 | 2.82 | False | None | None | False | None | False | 31828.0992 | 0 |
3171054 | 109175 | None | 2.4.2 V-I | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 9958.73 | 9958.73 | 6.19 | False | None | None | False | None | False | 61644.5387 | 0 |
3171055 | 109175 | None | 2.5.1 V-I | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11834.55 | 11834.55 | 4.22 | False | None | None | False | None | False | 49941.801 | 0 |
3171056 | 109175 | None | 2.5.1 V-I | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11138.4 | 11138.4 | 2.06 | False | None | None | False | None | False | 22945.104 | 0 |
3171057 | 109175 | None | 2.5.1 V-I | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11138.4 | 11138.4 | 6.91 | False | None | None | False | None | False | 76966.344 | 0 |
3171058 | 109175 | None | 2.5.1 V-I | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10442.25 | 10442.25 | 16.34 | False | None | None | False | None | False | 170626.365 | 0 |
3171059 | 109175 | None | 2.5.1 V-I | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10094.18 | 10094.18 | 0.62 | False | None | None | False | None | False | 6258.3916 | 0 |
3171060 | 109175 | None | 2.5.1 V-I | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6961.5 | 6961.5 | 1.03 | False | None | None | False | None | False | 7170.345 | 0 |
3171061 | 109175 | None | 2.5.1 V-I | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6961.5 | 6961.5 | 2.68 | False | None | None | False | None | False | 18656.82 | 0 |
3171062 | 109175 | None | 6.8 V-II | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. with all lead and lifts as per direction Engineering in Charge of the work with all lead and lifts as per direction Engineering in Charge of the work | Cum | 8367.45 | 8367.45 | 59.34 | False | None | None | False | None | False | 496524.483 | 0 |
3171063 | 109175 | None | 8.6.1 V-II | Providing 12mm thick cement plaster in single coat with cement mortar 1:3, to ceiling including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. | Sqm | 339.15 | 339.15 | 99.79 | False | None | None | False | None | False | 33843.7785 | 0 |
3171064 | 109175 | None | 8.2.1 V-II | Providing 15 mm thick cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 309.75 | 309.75 | 78.64 | False | None | None | False | None | False | 24358.74 | 0 |
3171065 | 109175 | None | 8.3.1V-II | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 371.7 | 371.7 | 90.87 | False | None | None | False | None | False | 33776.379 | 0 |
3171066 | 109175 | None | 9.23 V-II | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :*Polished granite stone slab Black, Cherry Red, Brown, Cat Eye,River Pink or equivalent. | Sqm | 2589.3 | 2589.3 | 54.0 | False | None | None | False | None | False | 139822.2 | 0 |
3171067 | 109175 | None | 8.33.1 V-ll | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 165.9 | 165.9 | 178.43 | False | None | None | False | None | False | 29601.537 | 0 |
3171068 | 109175 | None | 8.30 V-II | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 182.7 | 182.7 | 90.87 | False | None | None | False | None | False | 16601.949 | 0 |
3171069 | 109175 | None | 9.9 V-II | Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, FumeRed Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarsesand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointingthe joints with white cement and matching pigment etc., complete. | Sqm | 1129.8 | 1129.8 | 44.95 | False | None | None | False | None | False | 50784.51 | 0 |
3171070 | 109175 | None | 10.14 V-II | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size asapproved by Engineer- in-Charge, in skirting, risers of steps and dados,over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) andjointing with grey cement slurry @ 3.3kg/m2, including pointing in whitecement mixed with pigment of matching shade complete. | Sqm | 1161.3 | 1161.3 | 90.16 | False | None | None | False | None | False | 104702.808 | 0 |
3171071 | 109175 | None | 2.11a V-I | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification (The laps and wastages shall not be measured separately)) | Tonne | 93929.85 | 93929.85 | 4.28 | False | None | None | False | None | False | 402019.758 | 0 |
3171072 | 109175 | None | 11.34a V-II | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. | Kg | 176.4 | 176.4 | 275.94 | False | None | None | False | None | False | 48675.816 | 0 |
3171073 | 109175 | None | 11.5.1 V-II | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 4701.9 | 4701.9 | 12.6 | False | None | None | False | None | False | 59243.94 | 0 |
3171074 | 109175 | None | 8.33.3 V-II | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 145.95 | 145.95 | 26.1 | False | None | None | False | None | False | 3809.295 | 0 |
3171075 | 109175 | None | 15.1 V-lI | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 857.85 | 857.85 | 108.9 | False | None | None | False | None | False | 93419.865 | 0 |
3171076 | 109175 | None | 14.5.1 V-I | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern,with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors whereverrequired : Single half stall urinal with 5 litre P.V.C. automatic flushing cistern | Each | 9074.1 | 9074.1 | 10.0 | False | None | None | False | None | False | 90741.0 | 0 |
3171077 | 109175 | None | 14.1.1 V-II | Providing and fixing water closet squatting pan (Indian type W.C. pan )with 100 mm sand cast Iron P or S trap, 10 litre low level whiteP.V.C. flushing cistern, including flush pipe, with manually controlleddevice (handle lever) conforming to IS : 7231, with all fittings and fixturescomplete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests | Each | 5128.2 | 5128.2 | 4.0 | False | None | None | False | None | False | 20512.8 | 0 |
3171078 | 109175 | None | 14.7.3 V-II | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm
C.P. brass pillar taps | Each | 3009.3 | 3009.3 | 2.0 | False | None | None | False | None | False | 6018.6 | 0 |
3171079 | 109175 | None | 13.34 V-II | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank | Ltr | 9.45 | 9.45 | 1000.0 | False | None | None | False | None | False | 9450.0 | 0 |
3171080 | 109175 | None | 13.50.3 V-II | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 25 mm nominal dia Pipes | Mtr | 235.2 | 235.2 | 60.0 | False | None | None | False | None | False | 14112.0 | 0 |
3171081 | 109175 | None | 13.54 V-II | Constructing brick masonry chamber for underground C.I. inspectionchamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 500X700 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets :With common burnt clay (non modular) bricks of class designation 3.5 | No | 6591.9 | 6591.9 | 4.0 | False | None | None | False | None | False | 26367.6 | 0 |
3171082 | 109175 | None | 13.58 V-II | Providing and fixing PVC (S.W.R) Gully Trap 10cms x 10cms with allfitting arrangements & all necessary accessories complete. | No | 363.3 | 363.3 | 16.0 | False | None | None | False | None | False | 5812.8 | 0 |
3171083 | 109175 | None | 13.13 V-II | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 g. | No | 888.3 | 888.3 | 17.0 | False | None | None | False | None | False | 15101.1 | 0 |
3171084 | 109175 | None | 13.50.10 V-II | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittingsThis includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 150 mm nominal dia Pipes | Mtr | 1672.65 | 1672.65 | 30.0 | False | None | None | False | None | False | 50179.5 | 0 |
3171085 | 109175 | None | 8.80 V-II | Forming groove of uniform size in the top layer of plaster as per approvedpattern including repair to the edges of panels and finishing the groovecomplete as per specifications and direction of the Engineer-in-charge:20 mm to 25 mm wide to required depth. | Mtr | 69.3 | 69.3 | 60.0 | False | None | None | False | None | False | 4158.0 | 0 |
3171086 | 109175 | None | 1.3.1 PWD ELE V-VI | Supplying heavy gauge PVC Conduit piipe.... dia....mm thick with suitable size bends, metal junction boxes adhesive paste etc. by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19mm dia 2mm thick | Rmtr | 68.0 | 68.0 | 200.0 | False | None | None | False | None | False | 13600.0 | 0 |
3171087 | 109175 | None | 1.3.2 PWD ELE V-VI | Supplying heavy gauge PVC Conduit piipe.... dia....mm thick with suitable size bends, metal junction boxes adhesive paste etc. by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25mm dia 2mm thick | Rmtr | 79.0 | 79.0 | 120.0 | False | None | None | False | None | False | 9480.0 | 0 |
3171088 | 109175 | None | 2.2.1 V-I | Providing and laying in position Cement Concrete for all Foundation works.
The granite/trap/basalt crushed graded coarse aggregates and fine aggregates
as per relevant IS Codes machine mixed with super plasticizers laid in finished
layers, well compacted using needle vibrators, including all lead & lifts, cost
of all materials, quality confirming to the requirements of relevant IS codes,
labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6958.35 | 6958.35 | 47.68 | False | None | None | False | None | False | 331774.128 | 0 |