1716907241000 | 1 | None | None | Buildings | Construction of Anganwadi Center-1 at Bhankalga village in Chittapur Taluka under KKRDB for the year 2022-23 | 1270922.51 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3194384 | 109865 | None | 001 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Cum | 6961.5 | 6961.5 | 23.71 | False | None | None | False | None | False | 165057.165 | 0 | 3194385 | 109865 | None | 002 | Centering Charges for Footing 3 %with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Cum | 208.85 | 208.85 | 3.28 | False | None | None | False | None | False | 685.028 | 0 | 3194386 | 109865 | None | 003 | Centering Charges for Column 70%with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Cum | 4873.05 | 4873.05 | 3.54 | False | None | None | False | None | False | 17250.597 | 0 | 3194387 | 109865 | None | 004 | Centering Charges for Chajja 45%with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Cum | 3132.68 | 3132.68 | 0.53 | False | None | None | False | None | False | 1660.3204 | 0 | 3194388 | 109865 | None | 005 | Centering Charges Plinth Beam 50%with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Cum | 3480.75 | 3480.75 | 2.97 | False | None | None | False | None | False | 10337.8275 | 0 | 3194389 | 109865 | None | 006 | Centering Charges LB & RB 60% with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Cum | 4176.9 | 4176.9 | 5.24 | False | None | None | False | None | False | 21886.956 | 0 | 3194390 | 109865 | None | 007 | Centering Charges Slab 50% with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Cum | 3480.75 | 3480.75 | 8.15 | False | None | None | False | None | False | 28368.1125 | 0 | 3194391 | 109865 | None | 008 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification for building.with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | MT | 93929.85 | 93929.85 | 2.37 | False | None | None | False | None | False | 222613.7445 | 0 | 3194392 | 109865 | None | 009 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Cum | 8621.55 | 8621.55 | 30.44 | False | None | None | False | None | False | 262439.982 | 0 | 3194393 | 109865 | None | 010 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement
: 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Sqm | 404.25 | 404.25 | 340.86 | False | None | None | False | None | False | 137792.655 | 0 | 3194394 | 109865 | None | 011 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingwith all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Kgs | 176.4 | 176.4 | 223.02 | False | None | None | False | None | False | 39340.728 | 0 | 3194395 | 109865 | None | 012 | Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Sqm | 1461.6 | 1461.6 | 23.43 | False | None | None | False | None | False | 34245.288 | 0 | 3194396 | 109865 | None | 013 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates. with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Cum | 6527.85 | 6527.85 | 3.01 | False | None | None | False | None | False | 19648.8285 | 0 | 3194397 | 109865 | None | 014 | Flooring with 25mm thick polished shahabad slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications.with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Sqm | 1717.8 | 1717.8 | 45.32 | False | None | None | False | None | False | 77850.696 | 0 | 3194398 | 109865 | None | 015 | Providing and fixing in position Mathi / Nandi wood fully panelled shutters for windows with stiles and rails of 25mm. thick, 75mm wide in two halves with panels of 20mm thick including cost of materials, labour charges, usage charges complete as per specifications. (excluding cost of fixtures).with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Sqm | 6134.1 | 6134.1 | 10.08 | False | None | None | False | None | False | 61831.728 | 0 | 3194399 | 109865 | None | 016 | Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with , stiles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures).with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Sqm | 6029.1 | 6029.1 | 2.88 | False | None | None | False | None | False | 17363.808 | 0 | 3194400 | 109865 | None | 017 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and in- cluding water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Sqm | 143.85 | 143.85 | 163.47 | False | None | None | False | None | False | 23515.1595 | 0 | 3194401 | 109865 | None | 018 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Sqm | 93.45 | 93.45 | 126.88 | False | None | None | False | None | False | 11856.936 | 0 | 3194402 | 109865 | None | 019 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Sqm | 55.65 | 55.65 | 42.53 | False | None | None | False | None | False | 2366.7945 | 0 | 3194403 | 109865 | None | 020 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Sqm | 144.9 | 144.9 | 42.53 | False | None | None | False | None | False | 6162.597 | 0 | 3194404 | 109865 | None | 021 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Sqm | 52.5 | 52.5 | 22.68 | False | None | None | False | None | False | 1190.7 | 0 | 3194405 | 109865 | None | 022 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Sqm | 120.75 | 120.75 | 22.68 | False | None | None | False | None | False | 2738.61 | 0 | 3194406 | 109865 | None | 023 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge..with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Sqm | 333.9 | 333.9 | 11.4 | False | None | None | False | None | False | 3806.46 | 0 | 3194407 | 109865 | None | 024 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Sqm | 2142.0 | 2142.0 | 3.15 | False | None | None | False | None | False | 6747.3 | 0 | 3194408 | 109865 | None | 025 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2 including pointing in white cement mixed with pigment of matching shade complete.with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Sqm | 1161.3 | 1161.3 | 2.22 | False | None | None | False | None | False | 2578.086 | 0 | 3194409 | 109865 | None | 026 | Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately.with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Ltr | 9.45 | 9.45 | 1000.0 | False | None | None | False | None | False | 9450.0 | 0 | 3194410 | 109865 | None | 027 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia pipes. with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Mtr | 324.45 | 324.45 | 15.0 | False | None | None | False | None | False | 4866.75 | 0 | 3194411 | 109865 | None | 028 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia pipes. with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Mtr | 397.95 | 397.95 | 12.0 | False | None | None | False | None | False | 4775.4 | 0 | 3194412 | 109865 | None | 029 | Providing and fixing brass bib cock of approved quality : 15 mm nominal bore. with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Nos | 300.3 | 300.3 | 2.0 | False | None | None | False | None | False | 600.6 | 0 | 3194413 | 109865 | None | 030 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore. with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Nos | 567.45 | 567.45 | 1.0 | False | None | None | False | None | False | 567.45 | 0 | 3194414 | 109865 | None | 031 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests.with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Nos | 5128.2 | 5128.2 | 1.0 | False | None | None | False | None | False | 5128.2 | 0 | 3194415 | 109865 | None | 032 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes, adhesive paste etc., and runningbefore concreting the slab. The conduit should be tied to thereinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered usingPVC end enclosures, run with 18SWG GI fish wire wherever necessary 25mm dia 2mm thick with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Mtr | 66.0 | 66.0 | 120.0 | False | None | None | False | None | False | 7920.0 | 0 | 3194416 | 109865 | None | 033 | Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25mm dia 2mm thickwith all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Mtr | 79.0 | 79.0 | 120.0 | False | None | None | False | None | False | 9480.0 | 0 | 3194417 | 109865 | None | 034 | Supplying and fixing PVC/metal conduit Deep junction box 25mm deep junction box with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Mtr | 56.0 | 56.0 | 4.0 | False | None | None | False | None | False | 224.0 | 0 | 3194418 | 109865 | None | 035 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete 10"x7"x3" (254x178x76mm)with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Each | 112.0 | 112.0 | 5.0 | False | None | None | False | None | False | 560.0 | 0 | 3194419 | 109865 | None | 036 | Supplying And Fixing Metal Fan Box with Round Hook. with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Nos | 160.0 | 160.0 | 2.0 | False | None | None | False | None | False | 320.0 | 0 | 3194420 | 109865 | None | 037 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3Mtr from tapping point to out let via switch with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Nos | 285.0 | 285.0 | 4.0 | False | None | None | False | None | False | 1140.0 | 0 | 3194421 | 109865 | None | 038 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switch with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Nos | 394.0 | 394.0 | 6.0 | False | None | None | False | None | False | 2364.0 | 0 | 3194422 | 109865 | None | 039 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Long point above 6Mtr upto 10Mtr from tapping point to outlet via switch with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Nos | 570.0 | 570.0 | 6.0 | False | None | None | False | None | False | 3420.0 | 0 | 3194423 | 109865 | None | 040 | Point wiring using Copper wire with switch. Supplying and wiring adopting Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS:8130-1984 and (Virgin) PVC insulation sheathed suitabl 3C X 1.5Sq.mmwith all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Mtr | 72.0 | 72.0 | 120.0 | False | None | None | False | None | False | 8640.0 | 0 | 3194424 | 109865 | None | 041 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS:8130-1984 and (Virgin) PVC insulation sheathed suitabl 4C X 1.5Sq.mm with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Mtr | 94.0 | 94.0 | 120.0 | False | None | None | False | None | False | 11280.0 | 0 | 3194425 | 109865 | None | 042 | Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6Amps 2 Way with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Each | 128.0 | 128.0 | 4.0 | False | None | None | False | None | False | 512.0 | 0 | 3194426 | 109865 | None | 043 | Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board.6Amps 2way Switchwith all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Nos | 70.0 | 70.0 | 4.0 | False | None | None | False | None | False | 280.0 | 0 | 3194427 | 109865 | None | 044 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.1 to 3 Module with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Each | 137.0 | 137.0 | 20.0 | False | None | None | False | None | False | 2740.0 | 0 | 3194428 | 109865 | None | 045 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.6 Module with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Each | 175.0 | 175.0 | 10.0 | False | None | None | False | None | False | 1750.0 | 0 | 3194429 | 109865 | None | 046 | Supplying and fixing hylum plastic sheet 3mm thick with necessary nitches for fixing switches, regulators etc., and fixing on existing wood or metal box using N.F. screws.with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Sq CM | 0.41 | 0.41 | 5000.0 | False | None | None | False | None | False | 2050.0 | 0 | 3194430 | 109865 | None | 047 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Each | 3031.0 | 3031.0 | 2.0 | False | None | None | False | None | False | 6062.0 | 0 | 3194431 | 109865 | None | 048 | Fixing all types and all capacities of fluorescent / false ceiling/ spot light / CFL / LED fittings indoor on the wall / ceiling /rafters / girders using 23/0.0076” twin twisted PVC insulatedwires, required Nos of round blocks and clamps. with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Each | 122.0 | 122.0 | 6.0 | False | None | None | False | None | False | 732.0 | 0 | 3194432 | 109865 | None | 049 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Each | 315.0 | 315.0 | 2.0 | False | None | None | False | None | False | 630.0 | 0 | 3194433 | 109865 | None | 050 | Supplying and fixing regular MCB distribution boards on wall/ wood board / flush mounting using required clamps, bolts,nuts etc., with provision for fixing suitable type capacityMCB's single phase / 3 phase / single door with powdercoated painting. Made out of 14 SWG MS enclosure.with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Each | 4940.0 | 4940.0 | 1.0 | False | None | None | False | None | False | 4940.0 | 0 | 3194434 | 109865 | None | 051 | Supplying and fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materialsand 'C' Type curve, indicator ON/OFF, energy cross-3 withShort circuit breaking capacity of 10K and complete wiringas required confirming to IEC 60898..with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Each | 415.0 | 415.0 | 1.0 | False | None | None | False | None | False | 415.0 | 0 | 3194435 | 109865 | None | 052 | Supplying and fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materialsand 'C' Type curve, indicator ON/OFF, energy cross-3 withShort circuit breaking capacity of 10K and complete wiringas required confirming to IEC 60898.with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments incidental Charges etc., complete and as per specification and directions of the Engineer incharge of the work | Each | 739.0 | 739.0 | 1.0 | False | None | None | False | None | False | 739.0 | 0 |
|